HomeMy WebLinkAboutPermit M15-0121 - CHEVRON STATION - WALK-IN COOLERCHEVRON STATION 220 STRANDER BLVD M15-0121 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2623049104 220 STRANDER BLVD CHEVRON STATION MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: M15-0121 10/22/2015 4/19/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: JAMBO TEJ L L C+MARAKA INC 5727 128TH ST SW , MUKILTEO, WA, 98275 KIRAN ASHER 203 130 ST, SUITE 101, EVERETT, WA, 98208 SOUND SPECIALIZED SERVICES INC 12433 RUGGS LAKE RD , EVERETT, WA, 98208 SOUNDSS881MO 111 Phone: (425) 220-7278 Phone: (206) 427-3455 Expiration Date: 7/20/2016 DESCRIPTION OF WORK: MECHANICAL FOR NEW WALK-IN COOLER Valuation of Work: $10,000.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $324.28 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: •A)j t/ \ Date: ) ` I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: 1 c This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. (INSTALL ENVIRONMENTALLY APPROPRIATE HEAT DETECTION IN THE WALK-IN COOLER.) 13: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) (INSTALL WEATHER PROOF HORN/STROBE IN THE WALK-IN COOLER) 11: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 14: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 10: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWL Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 22-0 S-Tftm De. 9 W b Tenant Name: C}lsSJ 9 6 nl C M 012.A k.A 114 C, PROPERTY OWNER Name: 3' Bio 1 :;s u.G Address: 203 (30N sr s a , Stars_ 10 City: e v �T State: u A. Zip: 93 zo 8 CONTACT PERSON — person receiving all project communication Name: kt2A a Aso Address:Zos Gem sr S�, Su tirs_ l0 i City: Eve.a E.rr State: u Zip: 9 820 a Phone: 4Zc, 2.20 •12� gax' Email: IGIRAa �� Ms NI . CD 1" King Co Assessor's Tax No.: Suite Number: New Tenant: 2623o4-c1 I o 4- Floor: El Yes ENo MECHANICAL CONTRACTOR INFORMATION Company Name: >OU g b SPECt A u SE, CE 1 .SC-(2.U) Address: 12433 eLt tzC-a s LA rce... Q.tb City: State: & Zip: E 2e_TT.. ‘,..1 9 8 ZO Phone: Zo6 . 427- • 34sax: — Contr Reg $0 V tz ss g l614xp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ O 1000 . Describe the scope of work in detail: C44•j 1 c F p(L Nitt.•1 COS LE& Use: Residential: Commercial: Fuel Type: Electric New ❑ Replacement El New Lad' Replacement ❑ Gas Other: H:\ApplicationsWorns-Applications On Line \2011 Applications echanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment I Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: 16RAIN) A -1i 4 Mailing Address: 203 130 "2'i Sr SE, Su lft 1 0) Date: 61 ) / C `I S Day Telephone: A-2-c• 2 - • 9 2 48 vtl2M L -.4r 982-6,& • City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bit Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PermitTRAK PAID $324.28 M15-0121 Address: 220 STRANDER BLVD Apn: 2623049104 $324.28 MECHANICAL $311.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $216.95 PLAN CHECK FEE R000.322.102.00.00 0.00 $62.36 TECHNOLOGY FEE $12.47 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6238 R000.322.900.04.00 0.00 $12.47 $32.4.28 Date Paid: Wednesday, September 23, 2015 Paid By: KIRAN ASHER Pay Method: CREDIT CARD 00133D Printed: Wednesday, September 23, 2015 1:53 1 of 1 PM CRWSYSTEMS INSPECTION RECORD Retain a copy with permit IN Si CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: VIVA, Type of Inspectie1 /;;L/4-- Address: -// 2 d9O S'i-re --..l s- Date Called: Special Instructions: 07 ""' Date Wanted: %3d a.m. p.m. Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. COMMENTS: 12-2t % eo /Ss7 �'. Y cc�n�.i 22,,) .7;AiA5 Q Inspector: Date: i? L I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: d e7rra� Type of Inspecti n: /nA u, 47 Adr ss:e._� D�/� B/V `Da Called: S ecial Instructions: p hJ Date Wanted: V 22 p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: C;39t.„" Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit rTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: I --- �/'2e-fr, � pet) Type ofygspecti n: �' i ,c,�� / �L Address Az Dat al ed: Special Instructions: 4� Date Wanted: � / m p.rrt. Requester: Phone No: pproved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: REINSPECTION FEE REQUIRED. Prior to next inspect<fon, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit �l 5—d/t IN 'ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: CAe vro/t- Type of Inspectio �'%A Address: ‘ Date Called: .7Arm) Special Instructions: A2 Date Wanted: Cr; A- p.m. Requester: Phone No: Approved per applicable codes. L, Corrections required prior to approval. COMMENTS: 4;,' rtiiAa :=�' Inspector; 4a Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. .✓ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 A/115.---012) Project: . / % C4 e eZ, `) Type of Ins, ection: e "--, 9 e4/aid/ r e r Address: r-. � �at Called: c/ Special Instructions: Date Wanted: 1 l c9 �n Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: .46erove Inspector: Date: • REINSPECTION FEE REQUIRED, Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • FFAP-022Z-CFV-071 HFC, R-404A, 60Hz, 1- Phase, 208/230 V Availability : Standard US Wholesaler Mechanical FILE COPY Y a t, •a Electrical Unit Height (in): Unit Length (in): Unit Width (in): Ship Weight (lbs): Condensor Type: CopeVap Water Storage: Liquid Connection Size (in)/Type: Suction Connection Size (in)/Type: Discharge Line Size(in): Water Inlet (in): Water Outlet (in): Oil Type: Oil Recharge Amount (oz): 19.0 25.2 34.1 194.0 Air NA 3/8 S 7/8 S 0.5 POE 25 multi Prniforis Max Fuse Size: Min Circuit Ampacity: Compressor: Compressor LRA - Low: Compressor LRA - High: Compressor LRA - Half winding: Compressor RLA: UL: UL File #: UL Guide Card: Amps Per Motor: Fan Motor Quantity: 35 22.4 ZS15KAE-PFV-118 68.0 15.7 Air - Cooled Unit Performance REVIEWED FOR CODE COMPLIANCE APPROVED 2 OCT 13 15 1V r i Release Date: Compressor: Performance No: Evap Temp (°F) -25 -20 -15 -10 -5 0 5 10 15 20 25 30-Jan-2015 ZS15KAE-PFV-118 x 9234 Retum Gas Temp. (°F): 1 Subcooling (°F): Air Flow Rate (CFM) 90°F Ambient Air Temperature Unit Capacity (Btu/hr) 6,470 7,270 8,140 9,080 10,100 11,200 12,300 13,600 15,000 16,400 17,900 Cond. Temp. (°F) 102.3 103.2 104.2 105.3 106.5 108.0 109.1 110.5 112.1 113.7 115.4 Temp. Diff. (°F) 12.3 13.2 14.2 15.3 16.5 18.0 19.1 20.5 22.1 23.7 25.4 Ci1J of Tultwil BUILDING DIVISION 5 2170 EER (Btu!Wh): 3.4 3.7 4.0 4.4 4.7 5.0 5.3 5.7 6.1 6.5 7.0 amel djuldanic 09/21/2015 MISO 12) Page 1 Of 1 RECEIVED CITY OF TUKWILA SEP 2.3 2015 PERMIT CENTER Copyright © 2010 Emerson Climate Technologies, Inc. All rights reserved. FFAP-042Z-CFV-071 HFC, R-404A, 60Hz, 1- Phase, 208/230 V Availability : Standard US Wholesaler Mechanical Unit Height (in): 26.8 Unit Length (in): 28.2 Unit Width (in): 44.1 Ship Weight (lbs): 325.0 Condensor Type: Air CopeVap Water Storage: NA Liquid Connection Size (in)/Type: 1/2 S Suction Connection Size (in)IType: 1-1/8 S Discharge Line Size(in): 0.5 Water Inlet (in): Water Outlet (in): Oil Type: Oil Recharge Amount (oz): POE 42 flpEI +7 # Electrical Max Fuse Size: 60 Min Circuit Ampacity: 38.9 Compressor: ZS33KAE-PFV-118 Compressor LRA - Low: Compressor LRA - High: 146.0 Compressor LRA - Half winding: Compressor RLA: UL: UL File #: UL Guide Card: Amps Per Motor: Fan Motor Quantity: 28.2 1.5 2 Air - Cooled Unit Performance Release Date: Compressor: Performance No: 23-Jul-2013 Retum Gas Temp. (°F): ZS33KAE-PFV-118 x 1 Subcooling (°F): 8861 Air Flow Rate (CFM) 40 5 4240 90°F Ambient Air Temperature Evap Temp Unit Capacity Cond. Temp. Temp. Dill. EER (°F) (Btu/hr) (°F) (°F) (Btulwh): -30 12,200 99.5 9.5 3.7 -25 13,800 100.1 10.1 4.0 -20 15,500 100.8 10.8 4.4 -15 17,400 101.5 11.5 4.8 -10 19,500 102.3 12.3 5.2 -5 21,700 103.2 13.2 5.6 0 24,200 104.2 14.2 6.0 5 26,800 105.1 15.1 6.4 10 29,700 106.2 16.2 6.9 15 32,800 107.3 17.3 7.5 20 36,100 108.5 18.5 8.0 25 39,600 109.8 19.8 8.6 amel djuldanic 09/21/2015 Page 1 Of 1 Copyright © 2010 Emerson Climate Technologies, Inc. All rights reserved. 11,111130100) - ')NI 'S319010NH331 31Y11I1) N0SN3M3 1H9181d0O I' 0.0 9f\ y.y9 00.91 1 1, e o to o O ° o e . O • • is 1 �. o s ® , �• J c, 0 ££'I Q SS'V0 COMPRESSOR_MODEL_NO ZS26NAE-PFV ZS26NAE-TFS ZS26NAE-TFD ZS33KAE-PFV ZS33KAE•TFS ZS33NAE-TFD OCC = FFAP-040Z-CFV-011 FFAP-OAOZ•TFC•011 >2 O > 0- 2 0 oa v-CC W 0 4 W La 0 — 0 3 O a 8 8 8 8 a 8 8 as S 8 UPDATE PICtDIIIALLT CLAW S Y 8 r. 8 PICTORIALLY UPDATE CCH POSITIVE 8 2 C Q Q i 2 B 35 x— a? 8 Oa 405 o2 a 7 -WELD UNIT ASSM 3 O ce 0 — u CO O 0 0 La -o La - OWL! ♦;Y 60'£ 1 UNCONTROLLED - DO NOT MODIFY CD Heatcraft Refrigeration Products I Heatcraft Worldwide Refrigeration Page 1 of 1 41E10 Home > Products >Unit Coolers > Walk -In Unit Coolers > low Profile > Product Detail Bohn ( Larkin Climate Chandler M Soles Control Unit Coolers Compressorized Products Condensers & Fluid Coolers More Products & Services Resources & Information Enter Model Number E,,,,,,,,,,,,proliuuc°sand sutalnable mmmerval refngeratun Solutions i0M/Ddni, team er Product Search E4,1 T11e E-Sd4Atons"prl:gram 1.-. tatulesmn.ao* `>T +nfDrmelaf tr61.077 fronds. 4ip:1lp4✓ Oruf. Low Profile Bohn Standard Model: ADT180AK Bohn Configurable Model: ADT180SK Voltage: 115/1/60 Motor Type: PSC Motor List Price ($US): 3.695 Enter Zlp Code Where 10 ruyn Representative Product Image Product • Factory -Installed Shipped -Loose Specifications i Options Accessories General Information Performance Data Electrical Ratings Physical Data Connections Data (In.) Zeomner Pnnt Entail Downloads _ Sales Brochure u. Technical Bulletin air. Unit Coolers Installation & Operation Manual Refneerabon Systems Installation & Operation — Manual ;Category ;Unit Coolers ‘iType pWalk-In Unit Coolers Style !Low Profile Voltage j1 t 5/1160 iDelrost Type ,Air Defrost ;FPI i6 ;Rating Point °F "ICIT TD 25°F SST :Capacity (STUN) :18,000 ICFM 11,950 !Motor Type ;PSC Motor jNo. of fans 3 Motor HP ;1/15 ;Motor Voltage it15/1/60 'Motor Watts '246 !Motor Amps 'itieight (in.) +Depth (in.) ;Length (in.) Approx. Net Weight (lbs.) 15 14 7/8 6112 69 !Coil Inlet 0D 1/2 ;Con inlet ODF Suction ID ;718 !External Equalizer OD 1/4 :Drain MPT 3/4 (side Pod OD Hol Gas Pan Conns.OD Hen«en Waneelde Retngeraaun p:v.Wes dlmate<arltrol solutions for commer ie refryereeen and uqus10ol applications In more then 70 counties. We manufacture unit coolers, condensers, nonlyress0rized racks. condensing ants, reingeratlm systems end supermarket display taus Iledugn sot marketaeading brands, including Bohn, Larkn. Climate Control. ChaMlet. ltysorlWanen and Imerlink Haalrne Worldwide Refrigeration Is a business segment of Lemgx International . Inc.. leading global prodder of dimes eantrol solutions. 0 Cortyrghl Heascraft WoMwlda Reeigaratan 21111 0a RighIS Rasarsed. htto://www.heatcraftrnd.corn/t roductcatalog/productdetail.aspx?Tabldx=1&PID=41281&c... 9/22/2015 9/15/2015 Strander Chevron, Walk-in Cooler Box Specs From: Kiran Asher <kiranasher@aol.com> To: kiranasher <kiranasher@aol.com> Subject: Strander Chevron, Waik-in Cooler Box Specs Date: Tue, Sep 15, 2015 8:59 am Attachments: strander box 8-15.pdf (239K) __ore'PILE COPY Waik-in Cooler Box: COMMERCIAL COOLING CUSTOM BOX 13' 8"X44' 2". Sloped roof with membrane. 2) man doors 15) glass doors BOHN EVAPARATOR COILS 3 x PSCADT180 COPELAND SCROLL CONDENSING UNITS 1) 2 1/4 HP 404A 1) 4 1/4 HP 404A NC 2) RUUD 5 TON slit a/c units 92% multi position gas heat remote thermostat economizer w/ 26x12 relief dampers Dave Waite Sound Specialized Services Inc. 12433 Ruggs Lake Road Everett, WA 98208 206-427-3455 M(SO12! REVEO FOR CODE COMPLIANCE OMP CE APPROVED OCI 13 2015 &- Tukwila G DIVISION City BUILDI RECEIVED CITY OF TUKWILA SEP 2 3 2015 PERMIT CENTER https://mail.aol.com/webmai I-std/en-us/Pri ntMessage 1/1 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0121 DATE: 09/23/15 PROJECT NAME: CHEVRON STATION SITE ADDRESS: 220 STRANDER BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Public Works n J IM •lAY (Oi- IS Fire Prevention Structural Planning Division Permit Coordinator 111 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 09/24/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 10/22/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 Sound Specialized Services Inc Page 1 of 2 Hoare Inicio en Espanol Contact Search L&I '`1 A-Z Index Help My Secure t. I Safety Claims & Insurance Workplace Rights Trades & Licensing ashington State Department of abor & Industries Sound Specialized Services Inc Owner or tradesperson Principals Waite, David Lee, MEMBER Doing business as Sound Specialized Services Inc WA UBI No. 603 213 378 12433 Ruggs Lake Road EVERETT, WA98208 206-427-3455 SNOHOMISH County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. SOUNDSS881 MO Effective — expiration 07/20/2012— 07/20/2016 Bond ..............._ Contractors Bonding & Insurance Co Bond account no. SJ6993 $12,000.00 Received by L&l Effective date 07/20/2012 07/17/2012 Expiration date Until Canceled Insurance .... ................ Ohio Security Ins Co Policy no. BKS5655598 $1,000,000.00 Received by L&I Effective date 07/27/2015 02/20/2015 Expiration date 02/20/2016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ............................. No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603213378&LIC=SOUNDSS881 MO&SAW= 10/22/2015 BY: APPROVED APPROVED AS NOTED NOT APPROVED RESUBMIT DATE. IMPORTANT NOTE: PLEASE BE AWARE THAT THE ESTIMATED TIME OF COMPLETION BEGINS WHEN THE FINAL APPROVAL IS SIGNED. ANY CHANGES TO THE PREVIOUSLY APPROVED DRAWING WILL DELAY YOUR ORDER REVISIONS No changes shalt be made toscope of Tuwildrvsoei of Tukwila Building NOTE: Revisions will require a new plan submitta) and may indude additional plan review fed 0 0 C) 13'-8" [164] O.D. c 3"X3" POST (TYP.) EXISTING BUILDING WALL FLASHING & SEALANT BY G.C. DUROLAST ROOF MEMBRANE END CAP © BUILDING & COOLER WALL FOAMED IN PLACE CEILING PANELS FOAMED IN PLACE WALL PANELS T3.2.1 Durolast Roof Membrane (Sloped Roof) SLOPED FOAM DUROLAST ROOF MEMBRANE I— C� W z O CC Li 0) u NCO 6" (PLEAS VERIFY) 13'-2" (PLEASE VERIFY) SLOPED FOAM rDURALAST ROOF I MEMBRANE � , M W/ SLOPED FOAI . 'IW o 8'-OZ" REAR HEIG \TE I O ELEVATIO\ (LEFT SIDE) 3'-3" .c> 9' -114" [1194] COOLER 9' -114" [1194] '-6" 10'-04" [1204] 4'-54„ EXISTING BUILDING -' WALL (TYP.), PLEASE VERIFY WALL DEPTH 51 FILE Permit Aio. 9' - 98" [1 1721] (4) DOORS Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: in (27111 - 1a W O CU r--- City of Tukwila BUILDING DIVISION il4" SLOPE FINISH FLOOR L 12 p DOOR WITH NO TILE ALLOWANCE -FT SIDE ELEVATIO\ 5$" S!EPALAT - PE;. REQUIRED FOR �,/Mechanical tJ Electrical D LA \ VIEW 0 Plumbing Ef Gas Piping City of Tukwila E3U4i,piNG (�IViSKJiV EXISTING BUILDING r WALL. VERIFY WALL OPENING HEIGHT 9'-98" [1174] (4) DOORS LLI 0 O U Q r 44'-2" [530] O.D. C_D z z uJ Cl_ 0 CC 0 O 8" SLOPED FOAM 8- 5 DURALAST ROOF MEMBRANE / /// i / /i // ▪ -/ i// /7 // // /// O> =/// . // 7/ /a // /a/ 2'-6" N 00 1 3,, 11 8 Q I EVE COMPLIANCE AR OODPPR APPROVED A ()CI 1. 3 2015 Ci ff ul(Wila BUILDING DIVISION /CAM DOWN CEILING REQUIRES 6" MIN. FOR INSTALLATION ,7 / // /2/ /». /// / / ✓,/ .// _/ // /// /// // // // //» // // /v WAL<-I\ COOLS SPEC'S: LOS ANGELES R R & FAB LICENSE * CITY OF LOS ANGELES RESEARCH REPORT: RR 25314 * CITY OF LOS ANGELES FABRICATION APPROVAL ifFB02055 * 2009 FEDERAL ENERGY INDEPENDENCE & SECURITY ACT COMPLIANT CONSTRUCTION: NSF, LOS ANGELES R R, TONGUE & GROVE HIGH DENSITY FOAM RAIL, CAM DOWN CEILING 4" WALL PANELS 5" CEILING PANELS NONE FLOOR: PANEL FINISH: DOOR: REACH -IN DOORS: EACH DOOR ACCESSORIES: /1/ ACCESSORIES: REFRIGERATION: INTERIOR CEILING: EXTERIOR CEILING: INTERIOR WALLS: EXTERIOR WALLS: 26GA. STUCCO EMBOSSED 26GA. STUCCO EMBOSSED 26GA. STUCCO EMBOSSED 26GA. STUCCO EMBOSSED GALV. GALV. GALV. GALV. (1) 36" x 78" STD. CAM LIFT COOLER DOOR FLUSH MOUNTED DOOR INTERIOR DOOR AND SECTION FINISH TO MATCH PANELS EXTERIOR DOOR AND SECTION FINISH TO MATCH PANELS (1) 36" x 78" INSWING CAM LIFT COOLER DOOR FLUSH MOUNTED DOOR INTERIOR DOOR AND SECTION FINISH TO MATCH PANELS EXTERIOR DOOR AND SECTION FINISH TO MATCH PANELS (1) SET OF (1) 28"x79" ANTHONY #401 E GLASS REACH -IN COOLER DOORS W/ 2-PANE NHG, GALV. POSTS, T-8 LIGHTS, (7) 27" DEEP WHITE SHELVES PER DOOR, BLACK TAG MOLDING, SLIM LINE HANDLES DOOR AND FRAME: SMOOTH SILVER FINISH (2) SETS OF (1) 26"x79" ANTHONY #401 E GLASS REACH -IN COOLER DOORS W/ 2-PANE NHG, GALV. POSTS, T-8 LIGHTS, (7) 27" DEEP WHITE SHELVES PER DOOR, BLACK TAG MOLDING, SLIM LINE HANDLES DOOR AND FRAME: SMOOTH SILVER FINISH (3) SETS OF (4) 28"x79" ANTHONY #401 E GLASS REACH -IN COOLER DOORS W/ 2-PANE NHG, GALV. POSTS, T-8 LIGHTS, (7) 27" DEEP WHITE SHELVES PER DOOR, BLACK TAG MOLDI VG, SLIM LINE HANDLES DOOR AND FRAME: SMOOTH SILVER FINISH KASON LATCH W/ CYLINDER LOCK INSIDE SAFETY RELEASE #K58 (DOOR PULL HANDLES ND ES(INT./EXT.) (DOOR 'B') KASON CAM -RISE SPRING HINGE #1248 KASON CAM -RISE HINGE #1245 KASON DOOR CLOSER #1094 KASON 3-WAY LIGHT SWITCH W/ DIGITAL THERMOMETER KASON 3-WAY LIIGHTCSWI CH W/ PILOT LIGHT (RATED 15A, 120V AC) (DOOR 'B') KASON VAPOR PROOF CFL LIGHT FIXTURE (SURFACE MTD.) (SHIPPED LOOSE) #1806 (1) DURALAST ROOF MEMBRANE (1) SLOPED FOAM 6" INT./EXT. N.S.F. COVE BASE SILICONE/CAULKING & SCREW, TRIM BY OTHERS /; Li, /7 w -. / .�//,/7/✓/» /i / FINISH FLOOR DOOR WITH NO TILE ALLOWANCE F O\T ELEVATIO\ RECEIVED CITY OF TUKWILA SEP 2-3 2015 PERMIT CENTER Federal Law Minimum R Value Requirement as of Jan 2009 Min. R Value for Commercial Cooling Sections 3.5" 4" 5" 5.5" Mean Temp (°F) Federal Law Min. R= Cooler 26.6 30.4 38 41.8 55 R=25 Freezer 34.0 42.5 46.7 20 R=32 Floor 29.7 34.0 42.5 46.7 20 R=28 Sec. 340 of the Energy Policy and Conservation Act (42 U.S.C.6311) ASTM method C-518 8 08-20-2015 REVISED CEILING PANEL TO 5" TO MATCH BID (TMDC) /2\ 08-13-2015 REVISED SLOPE ON FOAM TO CORRECT HEIGHT (TMDC) 08-03-2015 ADDED SLOPPED FOAM, REVISED WALK-IN DOOR 'A' (TMDC) JOB NO.: 15-3307-0648 PANEL QTY. DATE: 07-28-2015 DRAWN: J.CERVANTEZ SCALE: 1/4" = 1'-O" SHEET: 1 OF 1 CUSTOMER: JOB NAME: Certified Listed COMMERCIAL COOLING PAR ENGINEERING, INC. 17855 E. ARENTH AVE. CITY OF INDUSTRY, CA 91748 TEL: (626) 964-8700 FAX: (626) 964-8777 CERTIFIED SMALL BUSINESS