Permit M15-0125 - WESTFIELD MALL - SUITE 712 - DEMOLITION / ROOFTOP HVAC UNIT
WESTFIELD MALL SUITE 712 21 S 0 UTH CENTER MALL M15-0125 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 9202470130 21 SOUTHCENTER MALL MECHANICAL PERMIT Project Name: WESTFIELD MALL - SUITE 712 Permit Number: M15-0125 Issue Date: 12/31/2015 Permit Expires On: 6/28/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 GRACE ROBINSON 2505 THIRD AVE, SUITE 324 , SEATTLE, WA, 98121 J E M CONSTRUCTION INC 29506 8TH AVE S , ROY, WA, 98580 JEMCOI*033DD Phone: (206) 720-7001 Phone: (253) 843-2765 Expiration Date: 5/15/2017 DESCRIPTION OF WORK: DEMOLITION OF AN EXISTING RESTAURANT TENANT SPACE AND EXTEND REQUIRED UTILITIES TO THE FUTURE TENANT SPACE AS REQUIRED. PROVIDE NEW ROOFTOP HVAC UNIT FOR FUTURE TENANT. Valuation of Work: $108,090.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $1,517.50 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Date:,Ck3-1 �JS This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 2: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 3: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 4: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 5: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 6: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 7: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 8: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 9: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 14: Readily accessible access to roof mounted equipment is required. 15: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 16: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 17: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 18: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 19: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 20: ***MECHANICAL PERMIT CONDITIONS*** 21: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 22: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 0703 1800 0609 0705 0701 0702 FIRE FINAL MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL SMOKE DETECTOR TEST a separate permit issued by the City of Tukwila the job site at the time of inspection. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: tIS Ol,S- (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: 21 Southcenter Mall King Co Assessor's Tax No.: 920247-0130 Suite Number: 712 Floor: 1 Westfield Mall, Suite 712 Re -demise PROPERTY OWNER Name: Westfield, Southcenter Address: 2800 Southcenter Blvd. City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Grace Robinson/Craft Architects Address: 2505 3rd Ave., Suite 324 City: Seattle State: WA Zip: 98121 Phone: (206) 720-7001 Fax: Email: grace@craftarchitects.com New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Demolition of an existing restaurant tenant space and extend required utilities to the future tenant space as required. Provide new rooftop HVAC unit for future tenant. 108,090 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement m Fuel Type: Electric 0 Gas m Other: H:\Applications\Fornss-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > 100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm 2 Unit Type Qty Air handling unit > 10.000 cfm 1 Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comin/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor QtY 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Grac Robinson/Craft Architects Mailing Address: 2505 3rd Ave., Suite 324 Date: eV2-5/2,0(S Day Telephone: (206) 720-7001 Seattle WA . 98121 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $6,494.19 D15-0247 Address: 141 SOUTHCENTER MALL Apn: 9202470130 $4,149.75 DEVELOPMENT $3,952.62 PERMIT FEE R000.322.100.00.00 0.00 $3,942.60 PLAN CHECK FEE R000.345.830.00.00 0.00 $5.52 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $197.13 TECHNOLOGY FEE R000.322.900.04.00 0.00 $197.13 D15-0265 Address: 680 SOUTHCENTER MALL Apn: 9202470010 $972.29 DEVELOPMENT $926.20 PERMIT FEE R000.322.100.00.00 0.00 $921.70 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $46.09 TECHNOLOGY FEE R000.322.900.04.00 0.00 $46.09 M15-0125 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $1,225.67 MECHANICAL $1,167.30 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $1,134.80 TECHNOLOGY FEE $58.37 TECHNOLOGY FEE R000.322.900.04.00 0.00 $58.37 PG15-0116 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $146.48 PLUMBING $139.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $107.00 TECHNOLOGY FEE $6.98 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R7017 R000.322.900.04.00 0.00 $6.98 $6,494.19 Date Paid: Thursday, December 31, 2015 Paid By: J E M CONSTRUCTION INC Pay Method: CHECK 14391 Printed: Thursday, December 31, 2015 11:14 AM 1 of 1 C SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK $291.83 M15-0125 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $291.83 MECHANICAL $291.83 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R6267 R000.322.102.00.00 0.00 $291.83 $291.83 Date Paid: Friday, September 25, 2015 Paid By: WESTFIELD Pay Method: CHECK 05000126 Printed: Friday, September 25, 2015 3:52 PM 1 of 1 C�SYSTEMS INSPECTION RECORD K ,-© 7, Retain a copy with permit , 5 ( IN ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd_,, #100, Tukwila, WA 98188 (206) 431-36 Permit inspection Request Line (206) 438-9350 P .fr645tt Type �o1lf,lnspe1. r( t_c{ i Addres Date Called: Special Instructions: d� alp i e Na r Mt Date Wanted: 3—(b -- IP a.m. p.m. Requester: Phone v-3 -066 - i z,-1` IApproved per applicable codes. C MMENTS: ECorrections required prior to approval. e_sceig vco-- eA, ( he_ tAif f: atrAci lAc:. -r- }�l�S7�(QW�S Inspector: Date: 3 `.8 14 1 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r6 MI INSPECTION RECORD Retain a copy with permit CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �,1�%��S -e (d Type Qf Inspectior YcG uEr/t —f'fi1 Addres 2f 5a && &f AM.( Date Call Special Instructions: old l—f�6b'e DUI. ,�/� i"t A 1 (/ i� / P Date Wanted: 3-- l / a.m. p.m. _ Requgacoi Phone No: 7/c3 --666 " STY Z11 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: r/ik Inspector: Date:3 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. City of Tukwila Department of Community Development October 06, 2015 GRACE ROBINSON 2505 THIRD AVE, SUITE 324 SEATTLE, WA 98121 RE: Correction Letter # 1 MECHANICAL Permit Application Number M15-0125 WESTFIELD MALL - SUITE 712 - 21 SOUTHCENTER MALL Dear GRACE ROBINSON, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) All plan sheets and the front cover of structural calculation produced by a Washington State licensed architect, structural engineer or civil engineer shall have on those sheets original wet stamp with wet signatures. (Electronic copies shall not be approved.) (BUILDING REVIEW NOTES) 1. Please provide plans with all sheets wet signed and wet stamped by the design professional in charge. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)431-3655. Sincerely, Bill Rambo2 Permit Technician File No. M15-0125 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0125 DATE: 10/29/15 PROJECT NAME: WESTFIELD MALL - SUITE 712 SITE ADDRESS: 21 SOUTHCENTER MALL Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: to--1 Building i 1 Sion Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 10/29/15 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 11/26/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0125 DATE: 09/25/15 PROJECT NAME: WESTFIELD MALL - SUITE 712 SITE ADDRESS: 21 SOUTHCENTER MALL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: &D 4 Al 1?) in Building Division 4. Public Works n A" Awc 1 6 fS Fire Prevention IP Structural Planning Division Permit Coordinator el PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 09/29/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n Approved with Conditions Denied (corrections entered in Reviews) ' (ie: Zoning Issues) DUE DATE: 10/27/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg k Fire ❑ Ping ❑ PW ❑ Staff Initials: (AA 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: M 15-0125 ❑ Response to Incomplete Letter # Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner C RECEIVED ,s0l,A ocr a 6 2615 Received at the City of Tukwila Permit Center by: ❑ Entered in TRAKiT on Project Name: Westfield Mall — Suite 712 Project Address: 21 Southcenter Mall Contact Person: C1 �,�.pei:0L-NA-5A.. Phone Number: ZCU (. — .7 2l) —7 m Summary of Revision: ' s aINL.0-JA ot. c r)Cpe.xrf '`lgto Sheet Number(s): 1 A n. I M 0. 2.) m f 3, Ann t. 1, nit I. "Cloud" or highlight all areas of revision including date of revision bkli) \applications\forms-applications on Iine\revision submittal Created: 8-13-2004 Revised: J E M CONSTRUCTION INC Home Inicio en .Espanol Contact Page 1 of 2 Search L&I A-Z Index Help My Secure t &1. Safety Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & Industries J E M CONSTRUCTION INC Owner or tradesperson Principals MILLER, JAMES E, PRESIDENT Doing business as J E M CONSTRUCTION INC WA UBI No. 601 770 782 29506 8TH AVE S ROY, WA98580 253-843-2765 PIERCE County Business type Corporation Governing persons JAMES E MILLER LORI K MILLER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ......................................................................... Meets current requirements. License specialties GENERAL License no. JEMCOI*033DD Effective — expiration 03/04/1997— 05/15/2017 Bond .............. CBIC Bond account no. SA7695 $12,000.00 Received by L&I Effective date 03/19/2002 03/01/2002 Expiration date Until Canceled Insurance ......................... American States Insurance Co $1,000,000.00 Policy no. 01 C12205496 Received by L&I Effective date 04/20/2015 04/16/2015 Expiration date 04/16/2016 Insurance history Savings ............ .. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Cause no. 10-2-11928-6 Dismissed https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601770782&LIC=JEMCOI*033DD&SAW= 12/31/2015 GENERAL PIPING SPECIALTIES DUCTWORK GENERAL NOTES - MECHANICAL NON-STRUCTURAL MECHANICAL COMPONENT NOTES DRAWING INDEX AHU-01 EXISTING MECHANICAL TO BE REMOVED EXISTING MECHANICAL TO REMAIN NEW MECHANICAL WORK MATCHLINE OR PROPERTY LINE ENLARGED PLAN BOUNDARY DETAIUPLAN IDENTIFIER SECTION IDENTIFIER ELEVATION IDENTIFIER REVISION DEFINITION AREA, AREA ENCIRCLED CONTAINS CHANGES MADE SUBSEQUENT TO PREVIOUS ISSUE REVISION CALLOUT FLAG NOTE CALLOUT DEMOLITION NOTE TAG MECHANICAL EQUIPMENT TAG NORTH ARROW INVERT ELEVATION OR POC ELECTRICAL PROVISIONS FOR MECHANICAL WORK 0i VFD LOCATION OF STARTER, DISCONNECT & CONTROLS VARIABLE FREQUENCY DRIVE ACCESS, EXCAVATION, AND BACKFILLING ACCESS DOOR (SPECIFIED OR AS SHOWN ON DWGS) MECHANICAL ACCESS (SPECIFIED OR AS SHOWN ON DWGS) 0 4 VALVES PIPE ELBOW UP OR PIPE TEE UP AND DOWN PIPE ELBOW DOWN PIPE TEE UP PIPE TEE DOWN PIPE RISE PIPE CAP PIPE PLUG FLOW DIRECTION PIPE BREAK PIPE CONNECTION D�0 VALVE: GATE, BALL, BUTTERFLY (REFER TO SPECIFICATIONS) GLOBE VALVE SOLENOID VALVE CHECK VALVE BALANCING VALVE PRESSURE REDUCING VALVE REDUCED PRESSURE. BACKFLOW ASSEMBLY SAFETY RELIEF VALVE TEMPERATURE/PRESSURE RELIEF VALVE II l TIP UNION FLANGE FLEX CONNECTOR THERMAUSEISMIC FLEXIBLE LOOP THERMAL EXPANSION JOINT STRAINER STRAINER WITH BLOW OFF VALVE PIPE ANCHOR ALIGNMENT GUIDE TEMPERATURE/PRESSURE TEST PORT THERMOMETER PRESSURE GAGE NATURAL GAS PIPING SYSTEM G MPG LPG I�I LOW PRESSURE NATURAL GAS PIPING MEDIUM PRESSURE NATURAL GAS PIPING LIQUID PETROLEUM GAS PIPING GAS COCK PRESSURE REGULATOR PRESSURE REGULATOR WITH VENT D O SEISMIC GAS SHUT-OFF j- - GAS PRESSURE REDUCING VALVE WITH VENT INLETS AND OUTLETS 24x24 500 II- I� --IF �I GRILLE REGISTER OR DIFFUSER TYPE RUNOUT SIZE (INCHES) AIR QUANTITY (CFM) CEILING DIFFUSER 1-WAY DIRECTION FLOW 2-WAY DIRECTION FLOW 3-WAY DIRECTION FLOW RETURN/RELIEF AIR GRILLE EXHAUST AIR GRILLE LINEAR DIFFUSER/GRILLE SUPPLY GRILLE RETURN/EXHAUST GRILLE TRANSFER GRILLE RETURN/EXHAUST AIRFLOW SUPPLY AIR FLOW CONTROLS (PLAN VIEW) 0 TU-XX DDC Y t HOOD FIRE DAMPERS THERMOSTAT OR TEMPERATURE SENSOR SENSOR: SHOWN WITH GUARD (TYPICAL ALL SENSORS) MOTORIZED DAMPER DUCT SMOKE DETECTOR TEMPERATURE TRANSMITTER DIRECT DIGITAL CONTROL PANEL SWITCH BY MECHANICAL T 1 T F/S F/S +2=T=+ T?-1-? -IE140 -0-+ FIRE DAMPER FIRE/SMOKE DAMPER SMOKE DAMPER CEILING FIRE DAMPER BDD 1 +r+ BDD 1 16x8--/ N 1---0 :1 1' 4r1) S +:=€ N BACKDRAFT DAMPER VOLUME DAMPER FLEXIBLE CONNECTION TO MECHANICAL EQUIPMENT TRANSITION - FROM RECTANGULAR TO ROUND TRANSITION - FROM ROUND TO RECTANGULAR RISE IN DUCT (D=DROP IN DUCT) DUCT SIZE (CLEAR INSIDE DIMENSION) RECTANGULAR DUCT UP RECTANGULAR DUCT DN ROUND DUCT UP ROUND DUCT DN FLEXIBLE DUCTWORK TRANSITION OR REDUCER (FOT=FLAT ON TOP, FOB=FLAT ON BOTTOM) TRANSITION - ECCENTRIC 45° ELBOW, R/D OR RJW=1.5 90° ELBOW, R/D OR R/W=1.5 SQUARE CORNER ELBOW WITH TURNING VANES 90° TAKE -OFF WITH 45° TAPER 45° TAKE -OFF RADIUS TAP IN WYE FITTING RADIUS TEE SQUARE TEE WITH TURNING VANES BULLHEAD TEE SECTION THRU RECTANGULAR SUPPLY AIR DUCT SECTION THRU RECTANGULAR RETURN OR OUTSIDE AIR DUCT SECTION THRU RECTANGULAR EXHAUST AIR DUCT SECTION THRU ROUND DUCT RECTANGULAR SUPPLY DUCT ROOF PENETRATION RECTANGULAR RETURN OR OUTSIDE AIR DUCT ROOF PENETRATION RECTANGULAR EXHAUST DUCT ROOF PENETRATION ROUND DUCT ROOF PENETRATION 1. COORDINATE MECHANICAL WORK WITH THAT OF OTHER TRADES (ELECTRICAL, ARCHITECTURAL, STRUCTURAL, CIVIL, AND LANDSCAPE). REFER TO ELECTRICAL AND ARCHITECTURAL DRAWINGS AND SPECIFICATIONS. COORDINATION SHALL OCCUR PRIOR TO FABRICATION, PURCHASE, AND/OR INSTALLATION OF ALL WORK. 2. COORDINATE HVAC SYSTEMS ROUTING PRIOR TO INSTALLATION. DURING LAYOUT COORDINATION, DUCTWORK TAKES PRECEDENCE OVER PLUMBING, INCLUDING FIRE PROTECTION SYSTEMS. 3. UNLESS OTHERWISE SPECIFIED, THE GENERAL CONTRACTOR (GC) SHALL BE RESPONSIBLE FOR PAINTING, CUTTING, AND PATCHING OF EXISTING FLOORS, WALLS, AND PARTITIONS IN THE EXISTING BUILDING. 4. REFER TO STRUCTURAL DRAWINGS FOR ALLOWABLE METHODS/LOADS FOR HANGING PIPING/DUCTS FROM STRUCTURAL MEMBERS. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFE KEEPING OF HIS OWN PROPERTY ON THE JOB SITE. OWNER ASSUMES NO RESPONSIBILITY FOR PROTECTION OF PROPERTIES AGAINST FIRE, THEFT, AND ENVIRONMENTAL CONDITIONS. MECHANICAL EQUIPMENT INSTALLATION NOTES 1. ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT: VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN BE MET. COORDINATE LOCATIONS OF MECHANICAL WORK AND WORK OF OTHER TRADES TO PROVIDE ACCESS CLEARANCES FOR SERVICE AND MAINTENANCE. PIPING NOTES 1. DISASSEMBLY PROVISIONS: PROVIDE UNIONS OR FLANGES AT PIPING CONNECTIONS TO EQUIPMENT, COILS, TRAPS, CONTROL VALVES, AND OTHER COMPONENTS TO ALLOW DISASSEMBLY FOR MAINTENANCE. 2. REFRIGERANT PIPING: PROVIDE SIZING AND INSTALLATION IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND IN SUCH A WAY AS TO BE INCONSPICUOUS AND FREE FROM ANY POSSIBLE CONDENSATION. PIPE SIZES NOTED ARE FOR REFERENCE AND SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE CONTROL WIRING BETWEEN EQUIPMENT FOR AN OPERATIONAL SYSTEM. SHEET METAL NOTES 1. VOLUME DAMPERS: PROVIDE A MANUAL VOLUME DAMPER FOR EACH SUPPLY, RETURN, AND EXHAUST OPENING, LOCATED AS FAR UPSTREAM AS POSSIBLE FROM THE OPENING. PROVIDE A MANUAL VOLUME DAMPER FOR BRANCH MAINS SERVING MORE THAN ONE OPENING. 2. ACCESS DOORS: PROVIDE AT DUCT SMOKE DETECTORS, BACKDRAFT DAMPERS, MOTOR OPERATED DAMPERS, [FIRE DAMPERS,] [SMOKE DAMPERS], COMBINATION FIRE/SMOKE DAMPERS, BOTH SIDES OF DUCT MOUNTED COILS, [AIRSTREAM MEASURING UNITS,] AND PLENUMS. 3. PROVIDE 12" LONG, '/z' WIDE FLUORESCENT ORANGE TAPE AT CONCEALED VOLUME DAMPER LOCATIONS. 1. THE COMPONENT IMPORTANCE FACTOR (Ip) FOR ALL NON-STRUCTURAL COMPONENTS SHALL BE: Ip = 1.0 2. THE FOLLOWING ITEMS ARE TAKEN DIRECTLY FROM THE 2012 INTERNATIONAL BUILDING CODE AND FROM THE AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) STANDARD 7. THE CONTRACTOR SHALL REFER TO THE ABOVE FOR ADDITIONAL INFORMATION, EXCEPTIONS, AND FURTHER DESCRIPTIONS. THE CONTRACTOR SHALL ADHERE TO REQUIREMENTS AND AS SUCH, SHALL BE INCLUDED WITHIN BID. ALSO REFER TO SPECIFICATION SECTION 230550. 3. 2012 IBC, 1613.1, SCOPE: ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND NON-STRUCTURAL COMPONENTS THAT ARE PERMANENTLY ATTACHED TO STRUCTURES AND THEIR SUPPORTS AND ATTACHMENTS SHALL BE DESIGNED AND CONSTRUCTED TO RESIST THE EFFECTS OF EARTHQUAKE MOTIONS IN ACCORDANCE WITH ASCE 7, EXCLUDING CHAPTER 14 AND APPENDIX 11A. 4. 2012 IBC, 1704.4, CONTRACTOR RESPONSIBILITY: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONSTRUCTION OF A SEISMIC -FORCE -RESISTING SYSTEM, DESIGNATED SEISMIC SYSTEM, OR SEISMIC -RESISTING COMPONENT LISTED IN THE STATEMENT OF SPECIAL INSPECTIONS AND SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY SHALL INCLUDE THE FOLLOWING: A. ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS; B. ACKNOWLEDGEMENT THAT CONTROL WILL BE EXERCISED TO OBTAIN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS APPROVED BY THE BUILDING OFFICIAL; C. PROCEDURES FOR EXERCISING CONTROL WITHIN THE CONTRACTOR'S ORGANIZATION, THE METHOD AND FREQUENCY OF REPORTING AND THE DISTRIBUTION OF THE REPORTS; D. IDENTIFICATION AND QUALIFICATIONS OF THE PERSON(S) EXERCISING SUCH CONTROL AND THEIR POSITION(S) IN THE ORGANIZATION. 4. DIVISION 23 RESPONSIBILITIES: A. HANGERS AND SEISMIC BRACING FOR MECHANICAL SYSTEMS SHALL BE DESIGNED AND SPECIFIED BY DIVISION 23. DIVISION 23 SHALL REFER TO THE MECHANICAL DRAWINGS FOR LOCATIONS OF EQUIPMENT AND HUNG MECHANICAL SYSTEMS AS STRUCTURAL DRAWINGS DO NOT SHOW THE LOCATIONS OF MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND OTHER COMPONENTS. B. DIVISION 23 SHALL COORDINATE THE SUPPORT SYSTEMS AND DESIGN LOADS FOR HUNG PIPING AND OTHER MECHANICAL SYSTEMS (INCLUDING COMBINED MULTIPLE PIPE RUNS) WITH THE GENERAL CONTRACTOR AND THE STEEL AND WOOD JOIST MANUFACTURERS IN ADDITION TO OTHER TRADES THAT MAY BE IMPACTED. ENERGY CODE NOTES 1. MOTORS: COMPLY WITH MINIMUM FULL LOAD EFFICIENCIES LISTED IN ENERGY CODE ENFORCED BY AHJ. 2. PIPING AND DUCT INSULATION: COMPLY WITH THICKNESSES AND TYPES LISTED IN ENERGY CODE ENFORCED BY AHJ UNLESS MORE STRINGENT REQUIREMENTS ARE SPECIFIED. [PROVIDE SCHEDULES ON DRAWINGS IF REQUIRED BY AHJ] 3. DUCT SEALING: SEAL DUCT TRANSVERSE JOINTS AND LONGITUDINAL SEAMS PER ENERGY CODE ENFORCED BY AHJ UNLESS MORE STRINGENT REQUIREMENTS ARE SPECIFIED. 4. RECORD DRAWINGS: SUBMIT TO THE BUILDING OWNER PER ENERGY CODE ENFORCED BY THE LOCAL AHJ. 5. OPERATION AND MAINTENANCE MANUALS: SUBMIT TO THE BUILDING OWNER PER ENERGY CODE ENFORCED BY THE LOCAL AHJ. 6. SYSTEM BALANCING: BALANCE HVAC SYSTEMS PER ENERGY CODE ENFORCED BY THE LOCAL AHJ AND SUBMIT A WRITTEN REPORT TO THE BUILDING OWNER. REFER TO SPECIFICATIONS FOR ADDITIONAL TESTING, ADJUSTING, AND BALANCING (TAB) REQUIREMENTS. 7. MECHANICAL SYSTEMS COMMISSIONING AND COMPLETION REQUIREMENTS: TEST SYSTEMS TO ENSURE THAT BUILDING SYSTEMS HAVE BEEN DESIGNED, INSTALLED, AND FUNCTION PROPERLY, EFFICIENTLY, AND CAN BE MAINTAINED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS IN ORDER TO SATISFY THE BUILDING OWNER'S DESIGN INTENT AND OPERATIONAL REQUIREMENTS PER ENERGY CODE ENFORCED BY THE LOCAL AHJ. REFER TO SPECIFICATIONS FOR ADDITIONAL COMMISSIONING REQUIREMENTS 8. THIS BUILDING AND ITS ENERGY SYSTEMS HAVE BEEN DESIGNED TO COMPLY WITH ENERGY CODE ENFORCED BY THE LOCAL AHJ. CONTRACTOR IS RESPONSIBLE FOR CORRECT INSTALLATION OF ENERGY CONSERVATION MEASURES. MO.1 MECHANICAL LEGEND AND GENERAL NOTES MO.2 MECHANICAL EQUIPMENT SCHEDULES MD1.1 MECHANICAL DEMOLITION FLOOR PLAN M1.1 HVAC FLOOR & MECHANICAL ROOF PLANS Sr7 ,RA E t Z:RMrT l:~;7r-)1 , "� FOR: 0 Ii13crlanical (i'Electrical C'lumbing GrEas Piping of Tukwila EI%`# r,Ns DIVISION 1 REVISIONS No changes shalt b' made to the scope l cf work t"tithm.,t prior approval of ;':..,'•,•;;'a Building Division. 1;777: r ,: :ca s tviil require a new plan submittal i and may include additional plan review fees. FILE COS' Permit Nos Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize tie violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: Date: / -,a-/ City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 3 2015 City of Tukwila BUILDING DIVISION CORREqT LTR# I RECEIVED CITY OF TUKWILA OCT 2 6 2015 PERMIT CENTER NOT ALL SYMBOLS MAY APPEAR ON THE DRAWINGS SOUTHCENTER 2505 Third Avenue Suite 324 Seattle, WA 98121 206.720.7001 phone 206.720.2949 fax www. crafta rch itects. com Q w z LL LLB Cr LL. °kir 14 moo W p Eucc CO o z 21 SOUTHCENTER MALL TUKWILA, WA 98188 COMLTANT HARGIS Hargis Engineers, Inc. 1201 Third Avenue, Suite 600 Seattle, WA 98101 t 1206.448.3376 f 1206.448.4450 w I hargis.biz to Z6 Submittals/Revisions: RESPONSE TO CORRECTION LETTER f REVISED OCTOBER 7, 2015 Sheet Title: MECHANICAL LEGEND AND GENERAL NOTES Date: Design: Drawn: Project No: Approved: 09/24/2015 MRD AO 15-145 BAH Building No: MO.1 HT CRAFT ARCHITECTS 2015 M001-002.dwg ABBREVIATIONS 0 DIAMETER, PHASE A AIR, AMPS ABV ABOVE AC AIR CONDITIONER ACU AIR CONDITIONING UNIT AD ACCESS DOOR ADA AMERICANS WITH DISABILITIES ACT AF AIRFOIL AFF ABOVE FINISHED FLOOR AFUE ANNUAL FUEL UTILIZATION EFFICIENCY AG ABOVE GROUND AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT AL ACOUSTIC LINED (DUCT) AMB AMBIENT AP ACCESS PANEL APD AIR PRESSURE DROP ARCH ARCHITECT ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR-CONDITIONING ENGINEERS, INC. ASSY ASSEMBLY ATM ATMOSPHERE BC BLOWER COIL BDD BACK DRAFT DAMPER BF BELOW FLOOR BHP BRAKE HORSE POWER BLW BELOW BOD BOTTOM OF DUCT BOP BOTTOM OF PIPE BOT BOTTOM BTUH BRITISH THERMAL UNIT PER HOUR BV BALL VALVE C CONDENSATE PIPING CAP CAPACITY CC COOLING COIL CD CEILING DIFFUSER, CONDENSATE DRAIN CFG CEILING FIRE DAMPER CFM CUBIC FEET PER MINUTE CG CEILING GRILLE CKV CHECK VALVE CLG CEILING, COOLING COMB COMBUSTION, COMBINATION COND CONDENSER, CONDENSATE CONN CONNECTOR CONT CONTINUE, CONTROL COP COEFFICIENT OF PERFORMANCE CU CONDENSING UNIT, CUBIC Cv FLOW COEFFICIENT CV CONSTANT VOLUME D DB dB DEG DIA DIM DISC DISCH DN DWGS DV (E) EA EAT EER EF EFF EG EL ELEC EMCS EQUIV ESP EVAP EXH EXT DRAIN DRY BULB (TEMPERATURE) DECIBEL DEGREE DIAMETER DIMENSION LOCATION OF STARTER, DISCONNECT AND CONTROLS DISCHARGE DOWN DRAWINGS DRAIN VALVE EXISTING EXHAUST AIR ENTERING AIR TEMPERATURE ENERGY EFFICIENCY RATIO EXHAUST FAN EFFICIENCY EXHAUST GRILLE, ENGINE GENERATOR ELEVATION ELECTRIC ENERGY MANAGEMENT AND CONTROL SYSTEM EQUIVALENT EXTERNAL STATIC PRESSURE EVAPORATOR, EVAPORATIVE EXHAUST EXTERIOR, EXTERNAL F FCU FD FFD FLA FLEX FLR FLTR FMS FPM FPS F/S FT FTU FV G GA GAL GALV GAHU GC GPH GPM GPRV GRD GWB H HC HGL HORIZ HP HTG HVAC HX HZ IAQ ID IE IN. IN. WG kW L LAT LBS LL LRA LR LVR LWR LWS LWT MAT MAX MBH MC MCA MECH MERV MIN MOCP MOD MPG MPS FAHRENHEIT, FIRE MAIN PIPING FAN COIL UNIT FIRE DAMPER, FLOOR DRAIN, DRY SPRINKLER ROUTING FUNNEL FLOOR DRAIN FULL LOAD AMPS FLEXIBLE FLOOR FILTER FLOW MEASUREMENT STATION (HVAC, PLUMBING) FEET PER MINUTE FEET PER SECOND FIRE/SMOKE DAMPER FEET, FIN TUBE FIN TUBE UNIT FACE VELOCITY GAS GAGE GALLONS GALVANIZED GAS AIR HANDLING UNIT GAS COCK, GENERAL CONTRACTOR GALLONS PER HOUR GALLONS PER MINUTE GAS PRESSURE REGULATING VALVE GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HUMIDISTAT, HEIGHT HEATING COIL REFRIGERANT HOT GAS LINE HORIZONTAL HORSEPOWER, HEAT PUMP HEATING HEATING, VENTILATING, AND AIR CONDITIONING HEAT EXCHANGER HERTZ INDOOR AIR QUALITY INDIRECT DRAIN INVERT ELEVATION INCH INCHES WATER COLUMN KILOWATT LENGTH LEAVING AIR TEMPERATURE POUND REFRIGERANT LIQUID LINE LOCKED ROTOR AMPS LINEAR RETURN LOUVER LOW WALL RETURN LOW WALL SUPPLY LEAVING WATER TEMPERATURE MIXED AIR TEMPERATURE MAXIMUM THOUSAND BTU PER HOUR MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MECHANICAL MINIMUM EFFICIENCY REPORTING VALUE MINIMUM MAXIMUM OVERCURRENT PROTECTION MOTOR OPERATED DAMPER MEDIUM PRESSURE GAS MEDIUM PRESSURE STEAM NA NC NIC NO NO. NTS OA OC OD OSA OV P PD PH POC PRV PSIG QTY RA REG REF RF RG RH RLA RPM RTU S SA SAT SCFM SCH SENS SF SG SIM SL SMACNA SO SOV SP SPS SS ST TD TEMP TG TOD TOP TOS TOF TSP T'STAT TYP UNO V VAV VCD VD VEL VENT VFD VOLT VTR W W/ WB WC WG WSEC WT NOT APPLICABLE NORMALLY CLOSED, NOISE CRITERIA NOT IN CONTRACT NORMALLY OPEN NUMBER NOT TO SCALE OUTDOOR AIR ON CENTER OUTSIDE DIMENSION OR DIAMETER OUTDOOR SUPPLY AIR OUTLET VELOCITY PRESSURE PRESSURE DROP PHASE POINT OF CONNECTION PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH GAGE QUANTITY RETURN AIR, RELIEF AIR REGISTER REFERENCE, RETURN/EXHAUST FAN RELIEF FAN RETURN GRILLE ROOF HOOD RATED LOAD AMPS REVOLUTIONS PER MINUTE ROOFTOP UNIT SENSOR SUPPLY AIR SUPPLY AIR TEMPERATURE STANDARD CUBIC FEET PER MINUTE SCHEDULE SENSIBLE SUPPLY FAN, SQUARE FOOT SUPPLY GRILLE SIMILAR REFRIGERANT SUCTION LINE SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, INC. SCREENED OPENING SHUTOFF VALVE STATIC PRESSURE STATIC PRESSURE STATION STAINLESS STEEL SOUND TRAP TEMPERATURE DIFFERENCE TEMPERATURE TRANSFER GRILLE TOP OF DUCT TOP OF PIPE TOP OF STEEL TOP OF FOOTING TOTAL STATIC PRESSURE THERMOSTAT TYPICAL UNLESS NOTED OTHERWISE VOLT VARIABLE AIR VOLUME VOLUME CONTROL DEVICE VOLUME DAMPER VELOCITY VENTILATION, VENTILATOR VARIABLE FREQUENCY DRIVE VOLTAGE VENT THRU ROOF WASTE, WATT, WIDE, WATER WITH WET BULB (TEMPERATURE) WATER COLUMN WATER GAGE WASHINGTON STATE ENERGY CODE WEIGHT STEEL GAS OR COPPER AC COND. DRAIN PIPE SOLID STRAPPING & SCREWS TO MATCH PIPE MATERIAL SECURE PIPE SUPPORTS TOGETHER WITH CONSTRUCTION ADHESIVE MAT COORDINATE WITH ROOFER ROOF PIPING SUPPORT SCALE: NONE FLEXIBLE CONNECTOR (TYP) CONDENSATE DRAIN, SEE COOLING COIL CONDENSATE DRAIN TRAP DETAIL PACKAGED ROOFTOP HVAC UNIT TO ROOF HEIGHT AS REQIRED FOR PROPER DRAIN PIPE SLOPING. OSA INTAKE BIRD SCREEN WATERPROOFING SEE ARCH DWGS NOTES: 1 i FACTORY ROOF CURB. SEE ROOFTOP HVAC UNIT FACTORY CURB DETAIL & ARCH DRAWINGS. FINISHED ROOF AND INSULATION, SEE ARCH DWGS SOUNDLINED SUPPLY AND RETURN DUCTS AS SPECIFIED. 1. PROVIDE ACOUSTICAL DUCT SOUNDLINING IN RETURN AND SUPPLY DUCTS FROM UNIT CONNECTION TO POINTS INDICATED ON DRAWINGS. 2. TRANSITION SUPPLY AND RETURN UNIT CONNECTIONS TO DUCT SIZES INDICATED ON DRAWINGS. 3. FACTORY ROOF CURB SHOWN. FIELD BUILT CURB SIMILAR. ROOFTOP HVAC UNIT Moz SCALE: NONE Mo.2 SCALE: NONE REVIEWED FOR CODE COMPLIANCE. APPROVED NOV 0 3 2015 City of Tukwila. BUILDING DIVISION. r y' OF TUKWILA OCT 2 6 2015 PERMIT CENTER SCIiTHCENTER architects 2505 Third Avenue Suite 324 Seattle, WA 98121 206.720.7001 phone 206.720.2949 fax www. crafts rch itects. co m LANDLORD WORK FOR FUTURE TENANT; DIN TAI FUNG J J 21 SOUTHCENTER s •_ -, TANT HARGIS Hargis Engineers, Inc. 1201 Third Avenue, Suite 600 Seattle, WA 98101 t 1206.448.3376 f 1206.448.4450 w I hargis.biz tJ�CZ Submittals/Revisions: Sheet Title: MECHANICAL ABBREVIATIONS AND DETAILS Date: Design: Drawn: Project No: Approved: 09/24/2015 MRD AO 15-145 BAH Building No: 10/12/15 - 6:50am Sheet No: • COPYRIGHT CRAFT ARCHffECTS 2015 ROOFTOP GAS / ELECTRIC UNIT SCHEDULE *OWNER FURNISHED MARK LOCATION AREA SERVED MANUFACTURER / MODEL NO. VENT. MIN OA (CFM) COIL MAX OA (CFM) SUPPLY FAN SUPPLY FAN MOTOR GAS FURNACE MARK TYPE MAX FLOW (CFM) ESP (IN WC) RPM SPEED CONTROL RPM BHP TYPE INPUT (MBH) OUTPUT (MBH) EAT (DEG F) LAT (DEG F) AFUE (%) STAGES (#) RTU-1 ROOF TENANT TRANE / YSD180 1700 6400 CENTRIFUGAL 6400 1.0 800 SZVAV 800 4.00 ODP 350.0 280 67 115 80 2 RTU-1 RTU-2 ROOF TENANT TRANE /YSD180 1700 6400 CENTRIFUGAL 6400 1.0 800 SZVAV 800 4.00 ODP 350.0 280 67 115 80 2 RTU-2 MAU-1 ROOF TENANT TRANE / GRAA70 12500 12500 CENTRIFUGAL 12500 1.25 VFD VFD VFD 15 ODP 700.0 560.0 20 60 80 MOD MAU-1 TOTALS 3,400 700 ROOFTOP GAS / ELECTRIC UNIT SCHEDULE (CONTINUED) MARK FILTER ELECTRICAL PHYSICAL MOUNTING / SUPPORT NOTES MARK TYPE MERV RATING FACE VEL (FPM) (STY/SIZE (#) (INxINxIN) V/0 MCA MOCP LxWxH (INxINxIN) WEIGHT (LBS) RTU-1 CARTRIDGE 8 500 (4)20x20x2 (4)20x25x2 460/3 40 50 122x84x54 2250 ROOF 1,2 RTU-1 RTU-2 CARTRIDGE 8 500 (4)20x20x2 (4)20x25x2 460/3 40 50 122x84x54 2250 ROOF 1,2 RTU-2 MAU-1 CARTRIDGE 8 500 460/3 18.5 20 195x53x47 2150 ROOF 1, 2 MAU-1 TOTALS NOTES: SHALL BE PROVIDED WITH A VISIBLE NAMEPLATE INDICATING THE SHORT CIRCUIT CURRENT RATING (SCCR) IN WITH UL REQUIREMENTS. REFER TO ELECTRICAL DRAWINGS FOR MINIMUM RATINGS. WITH 100% OUTSIDE AIR ECONOMIZER, ROOF CURB, AND GAS PRESSURE REGULATOR. 1. EQUIPMENT ACCORDANCE 2. PROVIDE DISCONNECT, EXHAUST FAN SCHEDULE MARK AREA SERVED MANUFACTURER / MODEL NO. CFM (CFM) E (INN)) ELECTRICAL WEIGHT (LBS) BACKDRAFT DAMPER AT FAN NOTES HP V/PH KEF-1 H1 & H2 GREENHECK USF-215-10 3200 3.0 3 HP 460V/30 172 N 1, 2 KEF-2 H3 & H4 GREENHECK USF-218-10 5000 3.0 5 HP 460V/30 248 N 1, 2 KEF-3 H5 GREENHECK USF-212-10 1800 3.0 2 HP 460V/30 130 N 1, 2 KEF-4 H6 & H7 GREENHECK USF-215-10 3800 3.0 5 HP 460V/30 172 N 1, 2 KEF-5 DISHWASHER GREENHECK USF-207-10 550 2.0 1/2 HP 460V/30 115 N 1, 2 EF-1 RESTROOMS GREENHECK USF-212-10 1800 1.0 1-1/2 HP 460V/30 130 Y NOTES: 1. BACKWARD INCLINED CENTRIFUGAL ROOF FAN U.L. 762 LISTED. 2. PROVIDE DISCONNECT, TIE DOWN POINTS, ROOF CURB AND HINGE KIT. DUCT SYSTEMS INSULATION SCHEDULE LOCATION OF DUCT DUCT SYSTEM TYPE DUCT CONFIGURATION INSULATION TYPE MINIMUM R-VALUE, INSULATION THICKNESS NOTES DUCT NOT WITHIN CONDITIONED SPACE SUPPLY, RETURN, EXHAUST MIXED, OUTSIDE, AND TRANSFER AIR DUCTS RECTANGULAR - EXPOSED RIGID BOARD R-7, 1 LAYER, 2 INCH THICK RECTANGULAR - CONCEALED DUCT WRAP R-7, 1 LAYER, 3 INCH THICK ROUND AND OVAL DUCT WRAP R-7, 1 LAYER, 3 INCH THICK DUCT WITHIN CONDITIONED SPACE SUPPLY, RETURN, EXHAUST AND TRANSFER AIR DUCTS RECTANGULAR - EXPOSED RIGID BOARD R-3.3, 1 INCH THICK ROUND AND OVAL DUCT WRAP R-3.3, 1 LAYER, 1-1/2 INCH THICK MIXED AND OUTSIDE AIR DUCTS RECTANGULAR - EXPOSED RIGID BOARD R-7, 1 LAYER, 2 INCH THICK RECTANGULAR - CONCEALED DUCT WRAP R-7, 1 LAYER, 3 INCH THICK ROUND AND OVAL DUCT WRAP R-7, 1 LAYER, 3 INCH THICK GAS SERVICE LOADS EQUIPMENT TAG TOTAL BTUH RTU-1 350 RTU-2 350 MAU-1 700 KITCHEN (EST) 1,500 TOTAL 2,900 GAS SIZING CHART PIPE SIZE 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" LENGTH CAPACITY IN CUBIC FEET OF GAS PER HOUR TBD 274 572 1077 2212 3314 6383 10173 17984 GAS SIZING BASED ON 2012 UNIFORM PLUMBING CODE , SECTION 1216.3 (1) LOW PRESSURE GAS FORMULA, LONGEST LENGTH = 225' @ 2PSI INLET, 1PSI PRESSURE DROP. Et Al7tiN1214.341) LOUf=PRESSURE GAS FORMULA (LESS THAN 1.5 lJ) [NFPA 5i4eS.4,11 D ( '6 \ rhei : .81 :) 19-17 (Tr xl fi in4ide diani ete r o f pipe, istehe3 input :rate appi i nc e(0, cubk feet le 30 inch racraury elutnn equivaient Length ofpi e, feat pressur t drop, incltrs water column n in accordance with Table 12163 t REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 3 2015 City of Tukwila WILDING DIVISION 3 ECEPIED CITY OF TUKWILA OCT 2 6 2015 PERMIT CENTER OIJTHCENTER archi tects 2505 Third Avenue Suite 324 Seattle, WA 98121 206.720.7001 phone 206.720.2949 fax www . c ra ft a rc h i to cts . co m ri z z z 1 w cc z O Q CC O CC 0 CI 21 SOUTHCENTER co co TINT HARGIS Hargis Engineers, Inc. 1201 Third Avenue, Suite 600 Seattle, WA 98101 t 1206.448.3376 f 1206.448.4450 w i hargis.biz Sheet Title: MECHANICAL SCHEDULE Date: Design: Drawn: Project No: Approved: 09/24/2015 NRD AO 15-145 BAH 10/12/15 - 6:50am Building No: COPYRIGHT CRAFT ARCHITECTS 2015 u u! MD1.1 HVAC DEMOLITION PLAN SCALE: 1/8" = 1'-0" SHEEP NOTES: 1. SEE SHEET MO.1 FOR ADDITIONAL GENERAL INFORMATION AND NOTES. 2. INFORMATION SHOWN IS FROM AS -BUILT DRAWINGS AND SOME FIELD INVESTIGATION, EXACT LOCATIONS AND ROUTING SHALL BE FIELD VERIFIED. 3. WORK SHOWN SHALL BE COORDINATED WITH ARCHITECTURAL PLANS. 4. DEMOLITION DRAWINGS ARE INTENDED TO GIVE A GENERAL REPRESENTATION OF THE DEMOLITION WORK INVOLVED AND DO NOT CONSTITUTE A COMPLETE LISTING OF ITEMS REQUIRING REMOVAL. 5. EXISTING DUCTS, EQUIPMENT, PIPING, AIR DEVICES SHOWN REPRESENT MAJOR MECHANICAL ITEMS TO BE REMOVED. SEE GENERAL NOTES AND DRAWING NOTES. 6. REVIEW SITE CONDITIONS AND INCLUDE REQUIRED DEMOLITION WORK. 7. INCLUDE COST FOR DEMOLITION AND DISPOSAL IN BID. REMOVE EXISTING ITEMS THAT ARE NOT REUSED. 8. REFER TO ARCHITECTURAL DRAWINGS TO DETERMINE WHERE CEILING/WALL AND ROOF WORK IS BEING PERFORMED. 9. SOME EXISTING CONDITIONS ARE CONCEALED OR UNKNOWN. VERIFY CONDITIONS PRIOR TO DEMOLITION. 10. WHERE EXISTING MECHANICAL WORK IS TO BE REUSED, COORDINATE WORK WITH OTHER DRAWINGS AND PROTECT FOR REUSE. 11. PROVIDE TEMPORARY CAP -OFF OF EXISTING SYSTEMS TO ALLOW CONTINUED USE OF SYSTEMS UNTIL THE FINAL SYSTEM COMPONENTS ARE INSTALLED AND CONNECTED. 12. REMOVE REFRIGERANTS; CHEMICAL, OILS AND SIMILAR ITEMS THAT ARE INSTALLED ALONG WITH DEMOLISHED MECHANICAL ITEMS. ASSUME THAT EQUIPMENT IS FULLY CHARGED AND DISPOSE OF OFF SITE IN ACCORDANCE WITH APPLICABLE CODES. 13. DEMOLISH ALL EXISTING CONTROLS, INCLUDING PNEUMATIC TUBING AND CONDUIT AND WIRING. DEMOLITION FLAG NOTES: DEMOLISH (E) DIFFUSERS, GRILLES, AND ASSOCIATED DUCTWORK. DEMOLISH (E) EQUIPMENT AND ASSOCIATED DUCTWORK. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 3 2015 City of Tukwila BUILDING DIVISION RECE;VED CITY OF TUKWILA OCT 2 6 2015 3ERMIT CENTER a QUTHCENTER architects 2505 Third Avenue Suite 324 Seattle, WA 98121 206.720.7001 phone 206.720.2949 fax www.craftarchitects.com W co W i w cr CV W LANDLORD WORK FOR FUTURE TENANT; PANT V z LL F- z 21 SOUTHCENTER MALL Go co oct HARGIS Hargis Engineers, Inc. 1201 Third Avenue, Suite 600 Seattle, WA 98101 t 1206.448.3376 f 1206.448.4450 w I hargis.biz Sheet Title: MECHANICAL DEMOLI11ON PLANS Date: Design: Drawn: Project No: Approved: 09/24/2015 MRD AO 15-145 BAH Building No: 10/12/15 - 6:50am ROOF DEMOLITION PLAN SCALE: 1/8" = 1'-0" Sheet Na: MD1.1 COPYRIGHT CRAFT ARCHITECTS 2015 7 11 7 10/12/15 - 6:50am 71 ❑ C f r — . 2 1 n 1"MPG 1-1/2"MPG 0-k 3/4"MPG 0 (E)2-1/2"MPG 7,1 S B MPG MPG n HVAC ROOF PLAN SCALE: 1/4" = 1'-0" 3/4"MPG MPG 71 SHEET NOTES: 1. SEE SHEET MO.2 FOR ADDITIONAL GENERAL INFORMATION AND NOTES. 2. DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION AND INSTALLATION OF MECHANICAL SYSTEMS. THE CONTRACTOR SHALL PROVIDE NECESSARY OFFSETS AND FITTINGS WHICH MAY BE REQUIRED DUE TO SPACE CONSTRAINTS OR OTHER CONDITIONS. 3. PROVIDE MISCELLANEOUS SUPPORTING STEEL, ETC. FOR THE INSTALLATION OF ALL MECHANICAL SYSTEMS. 4. COORDINATE FLOOR, WALL AND ROOF PENETRATIONS, LOUVER SIZES, ETC. WITH GENERAL TRADES. arch t t e c t s 5. VERIFY CLEARANCES PRIOR TO FABRICATION OF ANY WORK. 6. DUCTWORK SHALL NOT BE LOCATED OVER THE TOP OF ANY ELECTRICAL PANELS OR EQUIPMENT. 7. PROVIDE 1" DUCT LINING WHERE SHOWN. LINED DUCT SIZES ARE NET CLEAR INSIDE DIMENSIONS. SOUTHCENTEFI FLAG NOTES: MAINTAIN MANUFACTURER —RECOMMENDED CLEARANCES FOR MAINTENANCE AROUND UNITS. MOUNT UNIT ON CURB AT ROOF LEVEL. SEE 1 /M0.2 AND ARCHITECTURAL FOR CURB AND FLASHING DETAILS. GAS DOWN THROUGH ROOF. CAP DUCT DROPS BELOW ROOF. REVLEWED FOR CODE COMPLIANCE APPROVED NOV 0 3 2015 City of Tukwila BUILDING DIVISION RECEIVEID CITY OF TUKWILA OCT 2 6 2015 PERMIT CENTER 2505 Third Avenue Suite 324 Seattle, WA 98121 206.720.7001 phone 206.720.2949 fax www. crafta rch itects. co m Z W z [1:1_ 1-22 W p a 15 0 LL,z CC 0 � O p � O W 0 � 21 SOUTHCENTER MALL CatERLTANT HARGIS Hargis Engineers, Inc. 1201 Third Avenue, Suite 600 Seattle, WA 98101 t 1206.448.3376 f 1206.448.4450 w I hargis.biz Submittals/Revisions: RESPONSE TO CORRECTION LETTER # REVISED OCTOBER 7, 2015 Sheet Title: MECHANICAL PLANS Date: Design: Drawn: Project No: Approved: 09/24/2015 MRD AO 15-145 BAH Building No: Sheet No: M1.1 COPYRIGHT CRAFT ARCHITECTS 2015