Permit M15-0129 - CERIUM NETWORKS - HEAT PUMPS, DIFFUSERS, SENSORS, ETC
CERIUM NETWORKS 14240 INTERURBAN AVE S 170 M15-0129 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 3365901881 Permit Number: M15-0129 14240 INTERURBAN AVE S 170 Issue Date: 11/6/2015 Permit Expires On: 5/4/2016 Project Name: CERIUM NETWORKS Owner: Name: Address: Contact Person: Name: Address: BELLTOWN INVESTMENT PARTNER 2505 2ND AVE #520 , SEATTLE, WA, 98121 SHAWN TUTHILL 3132 NE 133RD ST, SEATTLE, WA, 98125 Contractor: Name: PSR-HVAC & MECHANICAL SERVICES Address: PO BOX 27073 , SEATTLE, WA, 98165 License No: PSRHVMS924JT Lender: Name: Address: !I/ Phone: (206) 367-2500 Phone: (206) 367-2500 Expiration Date: 4/30/2016 DESCRIPTION OF WORK: INSTALL FOUR (4) NEW SPLIT SYSTEM HEAT PUMPS. RELOCATE EXISTING DIFFUSERS AND TEMP SENSORS. REMOVE EXISTING REZNOR UNIT GAS HEATERS AND CAP PIPE. ADD NEW DDC CONTROLS Valuation of Work: $81,710.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $1,222.66 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: 7/7 Date: l/4�l� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be comp ied with, whether specified herein or not. The granting of this permit does not presume to give authority to e,iolate or cancel the provisions of any other state or local laws regulating construction or the performance of v.'ork. I am authorized to sign and obtain this development permj. and agree to the cgnditions ttachedhis y, rmit. Signature: Print Name: fV /4, 7"J1--f /2.Z This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be d.termined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKW�_ Community Development Department Permit Center 6300 Sor.rthcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwrw.T ukwi la W A. gov Mechanical Permit No. 'V t 1'S ' O Project No. Date Application Accepted: 10$� lG Date Application Expires: i4_\ln \ `[ (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: King Co Assessor's Tax No.: 3365901881 14240 Interurban Ave S, Tukwila, WA 98168 Cerium Networks PROPERTY OWNER _ Name: BELLTOWN INVESTMENT PARTNER Address: 2505 2nd Avenue # 520 City: Seattle State: WA Zip: 98121 CONTACT PERSON — person receiving all project communication Name: Shawn Tuthill Address: 3132 NE 133rd St City: Seattle State: Wa Zip: 98125 Phone: (206) 367-2500 Fax: (206) 368-6856 Email: Shawn.Tuthill@psrinechanical.com Suite Number: r Zvi 70/ Floor: 1 New Tenant: ® Yes ❑..No MECHANICAL CONTRACTOR INFORMATION Company Name: PSR Mechanical Address: 3132 NE 133rd St City: Seattle State: Wa Zip: 98125 Phone: (206) 367-2500 Fax: (206) 368-6856 Contr Reg No.: PSRHVMS924JT Exp Date: 04/30/2016 Tukwila Business License No.: BUS-0993498 Valuation of project (contractor's bid price): $ 81,710 Describe the scope of work in detail: Install four (4) new split -system heat pumps. Relocate existing diffusers and temperature sensors. Remove existing reznor unit gas heaters and cap pipe. Add new DDC controls. Use: Residential: New ❑ Replacement ❑ Commercial: New ® Replacement ❑ Fuel Type: Electric ® Gas ❑ Other: 1-1: Applications forms -Application, On Line 201 I Applications Mechanical Permit Application Revised 3-9-1 Ldocs Revised: August 2011 bit Page f of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >look btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfrn 4 Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser 21 Thermostat 4 Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 4 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZE Signature: NT: Date: /0/6 /Zo / S Print Name: Shawn M. Tuthill Day Telephone: (206) 367-2500 Mailing Address: 3132 NE 133rd St Seattle Wa 98125 City State Zip I1: Applications Forms -Applications On Line 21111 Applications Mechanical Permit Application Revised 8-0-11.docs Revised: Aueus121111 bit Page 2 01 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $1,222.66 M15-0129 Address: 14240 INTERURBAN AVE S 170 Apn: 3365901881 $1,222.66 MECHANICAL $1,175.63 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $908.00 PLAN CHECK FEE R000.322.102.00.00 0.00 $235.13 TECHNOLOGY FEE $47.03 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6351 R000.322.900.04.00 0.00 $47.03 $1,222.66 Date Paid: Tuesday, October 06, 2015 Paid By: PSR MECHANICAL Pay Method: CHECK 013092 Printed: Tuesday, October 06, 2015 2:25 PM 1 of 1 CSYSTEMS INSPECTION RECORD Retain a copy with permit —, •-• HJSPECTION NO. PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION .• 6300 Southcenter Blvd., #100, Tukwila: WA 98188 Permit Inspection Request Line (206) 438-9350 (2.06) 431-3670 Project: i . , i - 5 Oa- Type of lnsp ction: •iCit _WCA. Address: ittazi'd Date Clled:/.7 — 'Special Instructions: Date Wanted: i /7 ap.trz Requester: Phone No: [rived per applicable codes. Corrections required prior to approvak COMMENTS: 64 ve_ Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, tee must he paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection f V.SPECTION NO. INSPECTION RECORD r Retain a copy with permit ` �` ,� PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Ins ecttPn: A Address: /J Ar/&S Date Called: 1 �© `y a 4/4)4rcz Special Instructions:t Date Wanted: a.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Ai- f`:. ,r 'i/rr/ yrZ.e-r.5' %.i" LaNP Inspector: ./ CAiL.44/ Date //b Jj:t. 1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee*must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection: c INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj Type of I spectio Special Instructions: ���)) Wr 1"iese____ 41.1 e / y Date Wanted: a. - Requester: Kr/5 Phone No: _` „/ ❑ Approved per applicable codes. L.1 Corrections required prior to approval. COMMENTS: 7 9-Z Y®v4� OZA/4/ Pect rt c A/ „7-44,ret)x). tret'4L Inspector: CA-m09-c74- Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.\/ INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 m /5--1 z47 INSPECTION RECORD Retain a copy with permit PERMIT NO. Projecc : Type of{IInnn pey5Itio�nn: ` ♦ , Address: ( ry �- to .. r Ike Da a Called: li0 !✓ /i Special Instructions: ist Date Wanted: a.m. P.m- Requester: Kr/ fS Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project),-1 r N mar K> Type of I /"\-'0/4.5 A %/E�J�C Address: /J I tQg0 Tibet 4/4,3�i1 to 9Callned: � /'1 (` r/ Special Instructions: iletil Date Wanted: n if .� p.m. Requester: Phone No: 4'`3 '7 -2506 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: c/ititc/(- Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 /46—Oic Project:/l I ,,�/) %j Type of Inspection: / Address: O I`Ter1� r AC*et at /�® f/ // Instructions: Date Wanted: 1 / Vnl',Special Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: t4-r/,`4/1 rav 561) Inspector: �, a J oor Date: // g /- REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. City of Tukwila Department of Community Development October 19, 2015 SHAWN TUTHILL 3132 NE 133RD ST SEATTLE, WA 98125 RE: Correction Letter # 1 MECHANICAL Permit Application Number M15-0129 CERIUM NETWORKS - 14240 INTERURBAN AVE S Dear SHAWN TUTHILL, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) All plan sheets and the front cover of structural calculation produced by a Washington State licensed architect, structural engineer or civil engineer shall have on those sheets original wet stamp with wet signatures. (Electronic copies shall not be approved.) (BUILDING REVIEW NOTES) 1. Provide details to show how units shall be secured to the roof and/or curbs to resist wind and seismic loads. Include in the details methods for sealing any roof penetrations. (IMC 301.15 & 301.18) 2. All plan sheets provided by a design professional shall have wet stamp and wet signature. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)431-3655. Sincerely, Bill Rambo Permit Technician File No. M15-0129 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0129 DATE: 10/26/15 PROJECT NAME: CERIUM NETWORKS SITE ADDRESS: 12420 INTERURBAN AVE S Original Plan Submittal X Response to Correction Letter # 1 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: AT4vC Building Division Public Works IF Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/27/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/24/15 Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0129 PROJECT NAME: CERIUM NETWORKS SITE ADDRESS: 14240 INTERURBAN AVE S X Original Plan Submittal Response to Correction Letter # Revision # DATE: 10/09/15 Revision # before Permit Issued after Permit Issued DEPARTMENTS: CovrZ Building Division Public Works 1 Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 10/13/15 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: DUE DATE: 11/09/15 Approved with Conditions Denied (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Ns Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: M 15-0129 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Cerium Networks Project Address: 12420 Interurban Ave S Phone Number: 2a6712S Contact Person: AJ/C(L . //1..Xy(,-J-B (r v o TUKWIIA OCT262015 PERMIT CEITER Summary of Revision: St+E ,Z - efc.c,1o-SdeS ac(ress 1,./1 Co-,./c,e-envs R_A? 64. ..4 1zO , NG ! Qu m -r- t - & p i= GQ L) C Q v 'tJ 1— - ee pi 228 1 . 0 e r v to A + - 20 8 ((s . P4_,2 (9x,ZT Sheet Number(s): 1, 2- -A- Al 3 • 0 "Cloud" or highlight all areas of revision including day_of revisi, Received at the City of Tukwila Permit Center by: Iii}I0—Entered in TRAKiT on .1(1)" ,S \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: PSR-HVAC & MECHANICAL SEP'TICES Page 1 of 2 Home 1nicio en Espanol Contact Search L&I A•Z Index Ielp My Secure 1.10. Safety Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries PSR-HVAC & MECHANICAL SERVICES Owner or tradesperson Principals BAVINS, NEIL JONATHAN, PRESIDENT AUSTIN, MATTHEW W, VICE PRESIDENT STEINKE, CRAIG, CHIEF EXECUTIVE OFFICER O'DONNELL, STEPHEN 0 (End: 04/12/2012) RIST, STEVEN L (End: 04/12/2012) O'MALLEY, JAMES J, MEMBER (End: 04/14/2014) HOGERTY, REAGAN P, MEMBER (End: 04/14/2014) Doing business as PSR-HVAC & MECHANICAL SERVICES WA UBI No. 602 811 195 PO BOX 27073 SEATTLE, WA98165 206-367-2500 KING County Business type Corporation Governing persons CRAIG STEINKE INC MSHC; MATTHEW AUSTIN; NEIL BAVINS; SRUN KHOU; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. PSRHVMS924JT Effective — expiration 04/30/2008— 04/30/2016 Bond ................. International Fidelity Ins Co Bond account no. 0649932 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 03/28/2014 03/26/2014 Expiration date Until Canceled https://secure.lni.wa.gov/verify/Detail.aspx?UBI=60281 1195&LIC=PSRHVMS924JT&SAW= 11/6/2015 HVAC LEGE\ D: RISE -t THERMOSTAT LINE RISE 24x12 { } 24x12 10x8 171 f O 4 1 •- I P9 � 1 =L::3 t t i 0 1r rn 4 z DIRECTION OF RISE FOR DUCT DUCT (FIRST FIGURE DENOTES VIEW SHOWN) SINGLE UNE DUCTWORK INDICATES DUCT WITH VIEW DIMENSION LESS THAN 12 INCHES DUCT TAKEOFF SUPPLY DUCT TURNING TOWARD, UP SUPPLY DUCT TURNING AWAY RETURN DUCT TURNING TOWARD, UP EXHAUST DUCT TURNING AWAY EXHAUST DUCT TURNING TOWARD, UP RETURN DUCT TURNING AWAY ROUND DUCT TURNING TOWARD, UP ROUND DUCT TURNING AWAY OVAL DUCT TURNING TOWARD, UP OVAL DUCT TURNING AWAY CONICAL WYE CONICAL TEE VOLUME DAMPER(VD) FIRE SMOKE DAMPER(FSD) FIRE DAMPER(FD) MOTORIZED DAMPER(FD) DOUBLE LINE, LINED DUCT/ ACOUSTIC DUCT RECTANGLE TO RECTANGLE FITTING (RIGHT) ROUND TO ROUND HIGH/ MEDIUM VELOCITY FITTING ROUND TO ROUND FITTING LOW VELOCITY (PRESSURE) ROUND DUCT TAKE -OFF, TO SUPPLY DIFFUSER RECTANGLE/ ROUND RADIUSED ELBOW DUCT RECTANGULAR 90' ELBOW W/ TURNING VANES TYPICAL ECCENTRIC CONICAL DUCT REDUCTION FITTING CONCENTRIC CONICAL DUCT REDUCTION FITTING RECTANGLE TO ROUND FITTING SOUND ATTENUATOR TURNING VANES FLEXIBLE DUCT THERMOSTAT OR TEMPERATURE SENSOR THERMOSTAT OR TEMPERATURE SENSOR (CEILING) DUCT SMOKE DETECTOR SUPPLY AIR DIFFUSER ROUND SUPPLY AIR DIFFUSER RETURN AIR GRILLE EXHAUST AIR GRILLE SIDEWALL SUPPLY AIR GRILLE OR REGISTER SIDEWALL RETURN/EXHAUST AIR GRILLE OR REGISTER AC ACF ADA ADJ AFF AL ALIGN AP APPROX ARCH ASME AVG BAS 8FF BHP BLDG BOD BOP BTU BTUH BV CD CFM CG CI CLG CO CONN CONST CONT COORD CORR CU CU FT CU IN DB DEG DET DIA DIFF DIM DISCH DN DR DSD DWG EA EAT EF EFF EG ELECT ELEV EMERG ENT ESP EXH EXIST, (E) EXP F FC FCO FD FLA FLEX FLR FOB FOIC FOT FPM FPS FSD FT FU GAL GALV GEN GND GPH GPM H HP HR HTG HVAC HZ IBC IFGC N.C. cl& N.O. *N.C. N.O. N.C. N.O. N.C. " ' N.O. N.C. N.O. Ftig A33EVIATIONS: AIR CONDITIONING AIR CURTAIN FAN AMERICAN DISABILITIES ACT ADJUSTABLE ABOVE FINISHED FLOOR ACOUSTIC LINED ALIGNMENT ACCESS PANEL APPROXIMATELY ARCHITECTURAL AMERICAN SOCIETY OF MECHANICAL ENGINEERS AVERAGE BUILDING AUTOMATION SYSTEM BELOW FINISH FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR BALANCING VALVE CEILING DIFFUSER CUBIC FEET PER MINUTE CEILING GRILLE CAST IRON CENTERLINE CEILING CLEANOUT CONNECT; CONNECTED; CONNECTION CONSTRUCTION CONTINUOUS; CONTINUATION COORDINATE CORRIDOR CONDENSING UNIT CUBIC FEET CUBIC INCHES DRY BULB TEMPERATURE DEGREE DETAIL DIAMETER DIFFERENT1AL DIMENSION DISCHARGE DOWN DRAIN DUCT SMOKE DETECTOR DRAWING EACH ENTERING AIR TEMPERATURE EXHAUST FAN EFFICIENCY EXHAUST GRILLE ELECTRICAL ELEVATION EMERGENCY ENTERING EXTERNAL STATIC PRESSURE EXHAUST EXISTING EXPANSION FAHRENHEIT FANCOIL FLOOR CLEANOUT FIRE DAMPER FURNISHED AND INSTALLED BY OWNER FULL LOAD AMP FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OWNER INSTALLED BY CONTRACTOR FLAT ON TOP FEET PER MINUTE FEET PER SECOND FIRE SMOKE DAMPER FOOT; FEET FIXTURE UNITS GALLON GALVANIZED GENERAL GROUND GALLONS PER HOUR GALLONS PER MINUTE HEIGHT, HIGH HORSEPOWER HOUR HEATING HEATING, VENTILATING, AND AIR CONDITIONING HERTZ INTERNATIONAL BUILDING CODE INTERNATIONAL FUEL GAS CODE PIPI \G LEGEND: IMC IPC ID IE IN INSUL KW KWH L LAT LB LF LVG MA MAX MBH; MBUH MCA MCC MD MECH MFR MIN MISC MTD MTG N.C. N.O. NC NIC NTS OAT OD OH OA P PD P I. POC PRELIM PRES PRV PSI PSIG RA RECIRC RECT REF REG REQD RG RL RND RPM RV SCHED SF SG SO SOV SP SPEC SPECD SS STRUCT SWG SWR TBD TEMP TSTAT THRU TOD TOP TP TS TV TYP VD VEL VERT VOL WB WEF WG W/ W/O WT BALL VALVE BALL FLOAT VALVE BUTTERFLY VALVE GATE VALVE GLOBE VALVE CHECK VALVE PLUG VALVE PRESSURE REGULATING VALVE PRESSURE RELIEF VALVE 4A INTERNATIONAL MECHANICAL CODE INTERNATIONAL PLUMBING CODE INDIRECT DRAIN INVERT ELEVATION INCH INSULATE; INSULATION KILOWATT KILOWATTHOUR LENGTH LEAVING AIR TEMPERATURE POUNDS LINEAL FOOT LEAVING MIXED AIR MAXIMUM THOUSAND BRITISH THERMAL UNITS PER HOUR MINIMUM CIRCUIT AMPACITY MOTOR CONTROL CENTER MOTORIZED DAMPER MECHANICAL MANUFACTURER MINIMUM; MINUTE MISCELLANEOUS MOUNTED MOUNTING NORMALLY CLOSED NORMALLY OPEN NOISE CRITERIA NOT IN CONTRACT NOT TO SCALE OUTSIDE AIR TEMP OUTSIDE DIAMETER OVERHEAD OUTSIDE AIR PUMP PRESSURE DROP PHASE PROPERTY UNE POINT OF CONNECTION PRELIMINARY PRESSURE PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAGE RETURN AIR RECIRCULATING RECTANGULAR REFERENCE REGULATOR REQUIRED RETURN GRILLE RE -LOCATE ROUND REVOLUTIONS PER MINUTE REUEF VALVE SCHEDULE SQUARE FEET SUPPLY GRILLE SCREENED OPENING SHUT OFF VALVE STATIC PRESSURE SPECIFICATION SPECIFIED STAINLESS STEEL STRUCTURAL SUPPLY WALL GRILLE SUPPLY WALL REGISTER TO BE DETERMINED TEMPERATURE THERMOSTAT THROUGH TOP OF DUCT TOP OF PIPE TRAP PRIMER TEMPERATURE SENSOR TURNING VANE TYPICAL VENT VOLUME DAMPER VELOCITY VERTICAL VOLUME WET BULB TEMPERATURE WALL EXHAUST FAN WATER GAGE WITH WITHOUT WEIGHT AUTOMATIC AIR VENTLOAT VALVE C- MANUAL AIR VENT 0" DIFFERENTIAL PRESSURE GAUGE ASSEMBLY -0- DIFFERENTIAL PRESSURE SENSOR ASSEMBLY 111 GAUGE W/ COCK P/T PORT PIPE WELL THERMOMETER FLOW METER BTU METER W/ WELL SENSOR PIPE DOWN PIPE UP TEE DOWN TEE UP UNION CLEAN OUT REDUCER WYE STRAINER FLOW SENSOR MOTORIZED VALVE ACTUATOR SOLENOID VALVE ACTUATOR 2. HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF ACCOMPLISHING SETBACK OR SHUTDOWN DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION C403.2.4.3.2 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES, IF PROVIDED. 3. PROVIDE BALANCING DEVICES IN ALL BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION C403.27.3 C408.2.2.1 AND C4082.2.2 OF THE WSEC AND CHAPTER 6 OF THE IMC AND AS INDICATED ON THE CONTRACT DOCUMENTS. 4. ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDARDS FOR CONSTRUCTION OF GALVANIZED DUCTWORK. ALL DUCTWORK SHALL BE SEALED AS REQUIRED BY SECTION C403.2.7 "DUCT AND PLENUM..." OF THE WSEC. DUCT TAPE NOT ALLOWED. 5. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.7 OF THE WSEC. ALL PIPING SHALL BE INSULATED PER SECTION 1415.1 AND TABLE 14-6 OF THE WSEC. GENE�AL OYES: 1. COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE LATEST ADOPTED VERSION OF INTERNATIONAL BUILDING CODE (IBC), INTERNATIONAL MECHANICAL CODE (IMC), WASHINGTON STATE ENERGY CODE (WSEC), INTERNATIONAL PLUMBING CODE (UPC), INTERNATIONAL FUEL GAS CODE (IFGC), INTERNATIONAL FIRE CODE (IFC), NFPA AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL JURISDICTIONS. 2. CONTRACTOR SHALL COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS AND DUCT ROUTING CLEARANCES WITH THE STRUCTURAL, REFLECTED CEILING AND LIGHTING PLANS. 3. MAKE ACCEPTABLE ACCESS PROVISIONS FOR REMOVAL OF FILTER AND MAINTENANCE AND SERVICE FOR ALL MECHANICAL EQUIPMENT AND UNITS. REFER TO MANUFACTURER'S INSTALLATION GUIDE. 4. ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE. 5. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE DOCUMENTS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS MUST BE DETERMINED BY THE PROJECT SITE CONDITIONS AND SHALL HAVE THE APPROVAL OF THE PROJECT MANAGER BEFORE BEING INSTALLED. DO NOT SCALE DRAWINGS. 6. ALL ROOF PENETRATIONS SHALL BE MINIMUM OF 5 FEET AWAY FROM THE AREA/OCCUPATION SEPARATION WALLS. ALL PIPE, DUCT AND CONDUIT PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE. 7. ALL EQUIPMENT, DAMPERS, PIPING, AND ACCESSORIES IN CONCEALED SPACES REQUIRING ACCESS SHALL HAVE ACCESS DOORS. ALL ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED. COORDINATE LOCATIONS WITH ARCHITECT/OWNER/CONTRACTOR TO PROVIDE ACCESS DOORS. 8. ALL EQUIPMENT SHALL BE FREE FROM DEFECTS IN MATERIAL, WORKMANSHIP, AND SHALL BE OF THE KIND AND QUALITY DESCRIBED HEREIN. 9. ALL EQUIPMENT SHALL BE APPROVED FOR INSTALLATION IN THE STATE OF WASHINGTON AND SHALL HAVE ALL CERTIFICATIONS AND RATINGS REQUIRED TO MEET ALL ENERGY, POLLUTION, ENVIRONMENTAL, SEISMIC, ETC. CODES AND REGULATIONS. 10. VERIFY ALL THE MECHANICAL EQUIPMENT'S ELECTRICAL LOADS VOLTAGE/PHASE, ETC. WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING. 11. WHERE MULTIPLE RISERS OR HORIZONTAL LOOPS ARE USED, BALANCING VALVES IN THE RETURN LINES ARE REQUIRED. A CHECK VALVE SHALL BE PROVIDED IN EACH RETURN TO PREVENT TEMPORARY REVERSAL OF FLOW. 12. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL, STRUCTURAL, ELECTRICAL WORK, ETC., SHOWN ON CONTRACT DOCUMENT DRAWINGS. LOCATIONS AND SIZES OF ALL FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED WITH ALL OTHER TRADES INVOLVED. 13. ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICAL EQUIPMENT OR PIPING INSULATION IS APPLIED. 14. WHERE TWO OR MORE ITEMS OF THE SAME TYPE OF EQUIPMENT ARE REQUIRED, THE PRODUCT OF ONE MANUFACTURER SHALL BE USED. 15. REFER TO TYPICAL DETAILS FOR DUCTWORK, PIPING, AND EQUIPMENT INSTALLATION. 16. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE AS REQUIRED BY SECTION 1416.1 OF THE WSEC. THE DRAWINGS SHALL INDICATE THE LOCATION AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A MINIMUM, THAT HAVE BEEN DEVIATED FROM THESE DOCUMENTS. A COMPLETE RECORD OF CHANGES SHALL BE KEPT TO DATE ON A DAILY BASIS AND MADE ACCESSIBLE TO OWNER AND ENGINEER. 18. LOCATIONS AND SIZES OF ALL FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED WITH ALL OTHER TRADES INVOLVED. 19. REFER TO TYPICAL DETAILS FOR DUCTWORK, PIPING, AND EQUIPMENT INSTALLATION. 20. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE AS REQUIRED BY SECTION 1416.1 OF THE WSEC. THE DRAWINGS SHALL INDICATE THE LOCATION AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A MINIMUM, THAT HAVE BEEN DEVIATED FROM THESE DOCUMENTS. A COMPLETE RECORD OF CHANGES SHALL BE KEPT TO DATE ON A DAILY BASIS AND MADE ACCESSIBLE TO OWNER AND ENGINEER. 2012 WASHI\GTON STATE E\RGY CODE (wsEc) \OTES GEn RAL HVAC NOTES: 1. CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK (HVAC) ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. 2. INSTALL ALL DUCT MOUNTED SENSING AND CONTROL DEVICES IN LOCATIONS WITH STRAIGHT SECTION OF DUCT UP AND DOWNSTREAM AS RECOMMENDED BY THE MANUFACTURER FOR GOOD ACCURACY AND ACCESSIBILITY. 3. COORDINATE AND PROVIDE ALL DUCT TRANSITIONS REQUIRED FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE ALL DUCT DIMENSIONS BEFORE FABRICATION. 4. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS REQUIRED TO PROVIDE A VIBRATION FREE INSTALLATION, AND SEISMICALLY BRACED AS REQUIRED. PROVIDE VIBRATION ISOLATION FOR ALL MECHANICAL EQUIPMENT TO PREVENT TRANSMISSION OF VIBRATION TO BUILDING STRUCTURE. 5. CERTAIN ITEMS SUCH AS RISES AND DROPS IN DUCTWORK, ACCESS DOORS, VOLUME DAMPERS, ETC. ARE INDICATED ON THE CONTRACT DOCUMENT DRAWINGS FOR CLARITY FOR A SPECIFIC LOCATION REQUIREMENT AND SHALL NOT BE INTERPRETED AS THE EXTENT OF THE REQUIREMENTS FOR THESE ITEMS. 6. UNLESS OTHERWISE SHOWN, LOCATE ALL ROOM THERMOSTATS 4'-0" (CENTERLINE) ABOVE FINISHED FLOOR. NOTIFY THE PROJECT MANAGER OF ANY ROOMS WHERE THE ABOVE LOCATION CANNOT BE MAINTAINED OR WHERE THERE IS A QUESTION ON LOCATION. 7. ALL DUCTWORK SHALL CLEAR DOORS AND WINDOWS. 8. UNLESS OTHERWISE NOTED, ALL DUCTWORK IS OVERHEAD, TIGHT TO THE UNDERSIDE OF THE STRUCTURE (WITHIN TRUSSES), WITH SPACE FOR INSULATION IF REQUIRED. 9. MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE AS CODE PERMITS. BUT NO LONGER THAN 12 FEET. 10. ALL DUCTWORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS, INCLUDING DIVIDED DUCTS AND TRANSITIONS AROUND OBSTRUCTIONS. 11. PROVIDE ACCESS DOORS IN DUCTWORK TO PROVIDE ACCESS FOR ALL VOLUME DAMPERS AND OTHER ITEMS LOCATED IN THE DUCTWORK WHICH REQUIRE SERVICE AND/OR INSPECTION. 12. ALL AIR DISTRIBUTION SUPPLY OUTLETS SHALL HAVE VOLUME CONTROL DEVICES. 13. ALL 90 DEGREE TRUNK DUCT ELBOWS SHALL BE SMOOTH -ROUND OR SQUARE WITH TURNING VANES. 14. ALL FAN SYSTEMS WITH OVER 2000 CFM SHALL HAVE DUCT SMOKE DETECTORS IN THE RETURN AIR STREAM TO DISABLE FAN UPON SMOKE DETECTION DETECTION. DUCT SMOKE DETECTORS ARE NOT REQUIRED IN THE RETURN AIR STREAM WHERE ALL PORTIONS OF THE BUILDING SERVED BY THE AIR DISTRIBUTION SYSTEM ARE PROTECTED BY AREA SMOKE DETECTORS CONNECTED TO A FIRE ALARM SYSTEM IN ACCORDANCE WITH THE INTERNATIONAL FIRE CODE. THE AREA SMOKE DETECTION SYSTEM SHALL COMPLY WITH SECTION 606.4 OF THE IMC. DUCT/SMOKE DETECTORS SHALL BE LISTED BY AN APPROVED AGENCY AND FOR INSTALLATION IN AIR DUCTS PER IMC SECTION 606. 15. ALL MECHANICAL HEATING AND VENTILATION EQUIPMENT SHALL CONFORM TO SMACNA, LOCAL AND STATE REGULATIONS FOR SEISMIC RESTRAINT (INCLUDING PIPING AND DUCTWORK). 16. ALL RECTANGULAR DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. 17. SUPPLY AND RETURN DUCTWORK FOR HVAC TO HAVE 1" SOUND LINING FOR THE FIRST 10 FEET FROM UNIT DISCHARGE OUTLET. ALL DUCT LINING TO MEET AND EXCEED MOLD, HUMIDITY, EROSION RESISTANT, ETC. TO MEET IMC CHAPTER 6. 18. ALL RECTANGULAR DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. SUPPLY AND RETURN DUCTWORK FOR HVAC TO HAVE 1" SOUNDLINING FOR THE FIRST 10 FEET FROM UNIT DISCHARGE OUTLET. ALL DUCT LINING TO MEET AND EXCEED MOLD, HUMIDITY, EROSION RESISTANT, ETC. TO MEET IMC CHAPTER 6. ALL DUCTWORK TO BE CLASS -I AIR DUCTS. CLASS -II DUCTS SHALL NOT BE USED. REVISIONS No changes sya!I be made to the scope of wo7k witho:;; prior approval of ;-:. 'ila Building Division. IC'a r ; :. ,:3 wiil require a new plan submittal 1 and may include additional plan review fees. 1. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES INDICATED IN C403.2.3. OR TABLE C101.4.3.1 CORRE TION LTR#- 6. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM CALLOUTS PER SECTIONS C403.3.1, C403.1.10.1 THRU 3 AND C403.2.13 OF THE WSEC FOR FULL LOAD EFFICIENCIES. 7. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION C408.2.2 OF THE WSEC. 8. IF NOT SPECIFICALLY STATED ABOVE, CONTRACTOR SHALL COMPLY WITH THE WSEC ITEMS THAT DO APPLY TO THIS PROJECT 9. ALL PIPING INSULATION SHALL CONFORM TO THE 2012 SEC SECTION: C403.2.8 SEPARATE PERMIT F QUIRED FOR: 0 PJdschanical ©'Electrical C bp as Piping C � of Tukwila ["_,"_rn ". a DIVISION FILE COPY Permit No, f S ` .� [ 2-' Fin review approval is subject to errors and omissions. 7 roval ; t:onstruction documents does not authorize t: ‘fiolatien of .ny adopted code or ordinance. R of L;: proved Field Co • and conditi • ns is ac ow : d . d: By: Date: .pi PROJECT LOCATION SITE INFO ADDRESS: OWNER: PARCEL/TAX # LEGAL: RECEIVED CITY OF TUKWILA OCT 2 6 2015 PERMIT CENTER 14220 INTERURBAN AVE S TUKWILA, WA 98168 BELLTOWN INVESTMENT PARTNER 3365901881 REVFEWED FOR CODE COMPLIANCE APPROVED NOV 0 3 2015 AT City of TukViii{'a' BUILDING DIVISION! HILLMANS SEATTLE GARDEN TRS POR OF LOT 1 & ALL OF LOTS 2 THRU 7 & POR ADJ IN SE 1/4 OF SECTION 14-23-04 DAF - BEG SE COR OF SAID LOT 7 TH NLY ALG ELY LN 315 FT TO LFT BANK OF DUWAMISH RIVER AS ORIGINALLY PLATTED TH CONTG ON NLY PROD OF SD ELY 220 FT M/L TO LFT BANK AS EXISTED UNDER SUPERIOR COURT CAUSE NO 81-2-05910-4 TH WLY ALG SD BANK TO AN INTSN WITH NELY PROD OF SELY LN OF NWLY 72 FT OF SD LOT 1 TH SWLY ALG SD LN PROD 200 FT M/L TO LFT BANK OF DUWAMISH RIVER AS PLATTED IN ORIGINAL PLAT TH CONTG IN SWLY DIRECTION ALG SELY LN OF NWLY 72 FT OF SD LOT 1 DISTANCE OF 55 FT M/L TO SWLY LN OF SD LOT 1 TH SELY ALG SD LN TO INTSN WITH N MGN OF S 143RD ST FIRST AVE TH ELY ALG SD MGN TO TPOB-TGW POR FOSTER JOSEPH DC #39 BEING POR OF ABANDONED PUGET SOUND ELECTRIC RR R/W IN THE SW 1/4 OF SE 1/4 OF SD SEC 14 SD RR R/W BOUNDED ON NE BY MAULE AVE ON SW BY A LN 20 FT NE OF & PLT NELY MGN OF SR 181 UNDER REC #8905231113 ON THE SE BY R/W #5 & ON THE NW BY R/W #6 BOTH R/W DEFINED IN QCD AUD FILE # 6557639 - TGW VAC MAULE AVE ADJ TGW POR VAC ST ADJ SITE VICINITY AIL NTS MlSOl1?z 0 co U c ro a t0 Li) 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT r LL 0 ots 0 H 0) _ co 1- D 213 O Q W Zr COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBUSHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. I 1 REVISION SUBMITTAL SHEET 10/23/15 0 PERMIT SUBMITTAL 9/23/15 `No. Revision/Issue Date Sy TUTHILL ` Date SEPTEMBER 23, 2015 Lead Tech Engineered By N. SINGER \SEPTEMBER 23, 2015 P5053 Project Manager N. SINGER Scale AS NOTED Sheet MO.O City of Tukwila BUILDING DIVISION KEY PLAN SCALE: NTS NOTE: AREA OF WORK SITE MAP SCALE: 1 "=30'-0" REVIEWED FOR CODE COMPLIANCE ' APPROVED NOV 0 3 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 2 6 2015 PERMIT CENTER U co A Service Logic Company 114. 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT i m ti 0 w H N w z w z CO w z 0 N co co 0 rn COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. i N 1 REVISION SUBMITTAL SHEET 10/23/15 0 PERMIT SUBMITTAL 9/23/15 `No. Revision/Issue Date DrTawn By S. UTHILL SEPTEMBER 23, 2015 Lead Tech Engineered By N. SINGER Date SEPTEMBER 23, 2015 P5053 Sheet [Project Project anager N. SMINGER MO Scale AS NOTED Itj 116'—s" /— EXISTING 3'-6" PARAPET EXISTING ROOF CIr—„ .II I. 011 II m II 10 11 1 m —711 I11 1. III IN e11JJ 2'-7" L L CO N BUILDING B NORTH ELEVATION SCALE: 3/32"=1'-0" EXISTING 3'-6" PARAPET _ I I L L L I 1 I L L L II 1_ m- 10 1111 1I 1 I _L _ L \ \ — EXISTING ROOF EXISTING 3'-6" PARAPET L EXISTING " L L L ROOF — aco C I 2 co I I N P 81'-6 BUILDING B EAST ELEVATION SCALE: 3/32"=1'-0" BUILDING B SOUTH ELEVATION 7— EXISTING 3'-6" PARAPET EXISTING ROOF -----I—I- ------- —------I---I----F 1 I I 1 1 1 I I I 11 1 I I I I I I L L� L L L L EXISTING GRADE 7— EXISTING 3'-6" PARAPET SCALE: 3/32"=1'-0" L f EXISTING 3'-6" PARAPET EXISTING ROOF—\ IIII—lrg III EXISTING ROOF IT—'1r4 ITT —TI1 VT—TimIT"'WTI II II. NI 1111 .1 11I II 11 II 11I II 1111 II 1111 I1 111 n1 111 EXISTING ROOF 116'-5" 7— EXISTING 3'-6" PARAPET CV i REVIEWED FOR CODE COMPLIANCE { APPROVED NOV 0 3 2015 City of Tukwila BUILDING DIVISION J C N t0 N BUILDING B WEST ELEVATION RECEIVED CITY OF TUKWILA OCT 2 6 20i5 PERMIT CENTER 3 U CO A Service Logic Company 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206)367-2500 Fax (206) 368-6856 \ PSRHVMS924JT / z w to � � W 0 0 Ct J wz LI m z —J CO C w z W cc LL COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. / 1 1 REVISION SUBMITTAL SHEET 10/23/15 0 PERMIT SUBMITTAL 9/23/15 \No. Revisionhlssue Date3 /brawn By S. TUTHILL Date SEPTEMBER 23, 2015 Lead Tech Engineered By N. SINGER Date SEPTEMBER 23, 2015 5.0roject Sheet Manager [Project NSIN53GER MO.2 cale AS NOTED • SCALE: 3/32"=1'-0" RELOCATE EXISTING DIFFUSER RELOCATE EXISTING THERMOSTAT AXIS I m �'--•-- ,/,! P" omit Etal 1111 _win mod 114_7 iiir 1 B o RELO _ �lES11 I $IuIIiii11iIij!!jdlli! u� I IIIII$ 1 0 8. o !_ RELv ;e I I � iuiiiiipiimuii ,It�II1-L-11111111L--LMIll 111,. eft. �� XIS NG i kililEli _� Z- I �) 'u 3 .O ER OS� AT .IUiD ;ONO IZER 24"x24" LOUVER 1-1/8" SL 1/2" LL (TYP 4) 18"x18" LOUVER UP REMOVE EXISTING REZNOR UNIT GAS HEATERS. EXISTING GAS PIPE TO BE CAPPED ( Cc Cc REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 3 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 2 6 2015 PERMIT CENTER • U A Service Logic Company 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT r Ie 0 w z oes w 0 z J a_ LL' 0 0 LI- 0 z w 2 w 0 0 z z w 0 z J m z w u_ 0 0 ti W CD 0 w Z W Q m w cc 0 N d COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. 1 1 1 REVISION SUBMITTAL SHEET 10/23/15 0 PERMIT SUBMITTAL 9/23/15 `No. Revision/Issue Dat, /Drawn By S. TUTHILL Date SEPTEMBER 23, 2015 Lead Tech Engineered By N. SINGER Date 0 Project P5053 Sheet Project anager N. SMINGER 1 M 1 .1 Scale AS NOTED HEAT PUMP DETAIL SCALE: 1 "=1'-0" 4"X6"X6' PT SLEEPERS ROOFED IN TO MATCH EXISTING. CONNECT HEAT PUMP OUTDOOR UNIT TO SLEEPER WITH 1"x#12 TEK (TYP. OF 4) HEAT PUMP SCALE: 1 "=1'-0" SCREWS DETAIL x6"x6' PT SLEEPERS WITH GALVANIZED SHEET METAL CAPS. SLEEPERS TO SPAN MINIMUM OF TWO(2) ROOF FRAMING MEMBERS. 3/8"x 1-1 /2 ATTACHED I (TYP. OF 8) 3/8"x3" LAG SC ROOF DEC ING BELOW LAG SCREWS 0 SLEEPERS EWS THROUGH NTO STRUCTURE . OF 8) UNISTRUT - 90* FITTINGS (13/16" SERIES) PART # P6281 (TYP. OF 8) L F L r-- L 4"x6" PT SLEEPERS WITH GALVANIZED SHEET METAL CAPS. SLEEPERS TO SPAN MINIMUM OF TWO(2) ROOF FRAMING MEMBERS. (TYP) \� FC—HP-1 CONCRETE WALL 1-1/8" SL & 1/2" LL (TYP) FC—HP-2 I I I L_J J FC—HP-4 I I I I I I I I I FC—HP-3 I 1 f I I I J PIPING GALVANIZED SHEE ETAL PIPE & ELECTRIC ' •HING HVAC PLAN — ROOF PLAN SCALE: 1 /8"=1'-0" EQUIPMENT LOCATED ABOVE FIRST FLOOR CEILING (TYP 4) NOTES: QQ 36"x 8-1/2" BEAM • 25"x7" BEAM 0 16-1 /2"x30' TJI TRUSS 4' O.C. ® 16"x5" BEAM REVIEWED FOR 'CODE COMPLIANCE APPROVED NOV 0 3 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 2'6 2015 PERMIT CENTER ro ro a) CU w 0U • A Service Logic Company 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT r z CL LL 0 0 ce 1 0 0 0 LL- Z w 2 w 0 0 z w F— et- 0 0 J w 1- z w U u_ COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. I N 1 REVISION SUBMITTAL SHEET 10/23/15 0 PERMIT SUBMITTAL 9/23/15 `No. Revision/Issue Date, 'brawn TUTHILL Date SEPTEMBER 23, 2015 Lead Tech NEngin. SNeereId By GER Date Project P5053 Sheet Project Manager N. SINGER 1 M 1.2 Scale AS NOTED �r 1 SPLIT SYSTEM AIR HANDLER EQUIPMENT SCHEDULE MARK LOCATION UNIT HEATING ELECTRIC OPERATION BASIS OF DESIGN SERVES REMARKS TOTAL CFM OSA CFM SP HP/BHP KWH @ 208V MOCP (AMPS) MCA VOLTAGE/PHASE WEIGHT: Lbs. MANUFACTURER MODEL FC-HP-1 (B-13) 1ST. FLOOR 1,600 120 0.5 0.75 10KW 60 58.5 208/230/1PH 157 CARRIER FB4CNP048L00 SUITE 170E ECONOMIZER, SMOKE DETECTOR, & CONDENSATE PUMP FC-HP-2 (B-14) 1ST. FLOOR 1,600 120 0.5 0.75 10KW 60 58.5 208/230/1PH 157 CARRIER FB4CNP048L00 SUITE 170B ECONOMIZER, SMOKE DETECTOR, & CONDENSATE PUMP FC-HP-3 (B-11) 1ST. FLOOR 1,600 120 0.5 0.75 10KW 60 58.5 208/230/1PH 157 CARRIER FB4CNP048L00 SUITE 170B ECONOMIZER, SMOKE DETECTOR, & CONDENSATE PUMP FC-HP-4 (B-12) 1ST. FLOOR 1,600 120 0.5 0.75 10KW 60 58.5 208/230/1PH 157 CARRIER FB4CNP048L00 SUITE 170B ECONOMIZER, SMOKE DETECTOR, & CONDENSATE PUMP SPLIT SYSTEM HEAT PUMP EQUIPMENT SCHEDULE MARK LOCATION COOL 4G HEATING SOUND ELECTRICAL OPERATION BASIS OF DESIGN SERVES REMARKS NOM. TONAGE TOTAL (Btuh) SENSIBLE (Btuh) SEER EER CAP. (8 47 F (Btuh) DBA (Dba) MOCP (AMPS) MCA VOLTAGEIPHASE . HEIGHT: in MANUFACTURER MODEL OD-HP-1 (B-13) Rooftop 4 Tons 47,000 35,270 13 11 45,000 80 10 8.5 460/3 208 28.44 CARRIER 25HCD348A006 A006 SUITE 170B CONNECTED TO FC-HP-1 OD-HP-2 (B-14) Rooftop 4 Tons 47,000 35,270 13 11 45,000 80 10 8.5 460/3 208 28.44 CARRIER 25HCD348A006 A006 SUITE 170E CONNECTED TO FC-HP-2 OD-HP-3 (6-11) Rooftop 4 Tons 47,000 35,270 13 11 45,000 80 10 8.5 460/3 208 28.44 CARRIER 25HCD348A006 A006 SUITE 170B CONNECTED TO FC-HP-3 OD-HP-4 (8-12) Rooftop 4 Tons 47,000 35,270 13 11 45,000 80 10 8.5 460/3 208 28.44 CARRIER 25HCD348A006 A006 SUITE 170B CONNECTED TO FC-HP-4 Unit Report For 4 ton split hp Project:-Untitledl0 Prepared By: 08/19/2015 Outdoor Unit Parameters Unit Model. 25HCD Unit Size: _ 4 Tons Voltage. 460/3 V-Ph-Hz Outdoor Unit Dimensions and Weight Unit Length. 31.1875 in Unit Width' 31.1875 in Unit Height. 28.4375 in Unit Shipping Weight. 228. lb Indoor Unit Parameters Unit Model. FB4C Unit Size• 48,000 Btuh Cabinet Style. TXV Voltage. 208/230-1-60 V-Ph-Hz Heating Size• No Heat Indoor Unit Dimensions and Weight Unit Length* 22.0625 in Unit Width. 21.125 in Unit Height. 49.625 in Unit Shipping Weight. 157. lb Limited Warranty (Years) Item Original Owner Subsequent Owner Parts 10* (or 5) 5 *When registered within 90 days of installation to the original owner. Ordering Information Part Number Description Quantity Outdoor Unit 25HCD348A006 25HCD Comfort Series Heat Pump with Puron Refrigerant 4 Tons Cooling 1 13 SEER @ ARI Conditions 1 Dense Grille 1 Accessories KSALA0701AAA MotorMaster Low Ambient Controller for Outdoor Unit 1 KAACS0201 PTC Start Assist - PTC for Outdoor Unit 1 KHAIR0201AAA Isolation Relay for Outdoor Unit 1 KSAFT0101AAA Evaporator Freeze Thermostat for Outdoor Unit 1 KSALA0301410 Low -Ambient Pressure Switch for Outdoor Unit 1 KSATX0401 PUR Thermostatic Expansion Valve (Hard Shutoff) for Outdoor Unit 1 HC40GE466 Ball Bearing Fan Motor for Outdoor Unit 1 Indoor Unit FB4CNP048L00 FB4C Base Series Fan Coil with Puron 48000 BTU Cooling 1 TXV 1 Aluminum 1 Accessories KFCEH2601 C10 10 kW Electric Heater with Circuit Breaker for Indoor Unit 1 The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product Residential Carrier Products Bldr 1.19u Page 4 of 13 Performance Summary For 4 ton split hp Project:-Untitledl0 Prepared By: 08/19/2015 System Performance System: 25HCD/FB4C System Quantity. 1 Altitude. 0.0 ft Linear Pipe Length: 0.0 ft COP @ 47 F. 3.58 COP @ 17 F: 2.50 SEER @ ARI Conditions* 13.0 EER @ ARI Conditions 11.0 HSPF @ ARI Conditions: 7.7 Actual Airflow* 1600.0 CFM Standard Airflow. 1600.0 CFM Total Net Clg Capacity. 47.00 MBH Net Sensible Clg Capacity. 35.27 MBH Htg HP Capacity. 45.00 MBH Htg HP Integrated Capacity: 45.00 MBH Heating, HP Compressor Power 3.68 kW Total System Power 4.27 kW System Parameters Outdoor Unit Parameters Unit Model. 25HCD348A006 Unit Size (Nominal). 4 Tons Voltage. 460/3 V-Ph-Hz Htg Ent Air DB• 70.0 °F Htg Lvg Air DB' 96.0 °F Clg Ent Air DB Ambient* 95.0 °F Htg Ent Air DB Ambient. 47.0 °F Indoor Unit Parameters Unit Model. FB4CNP048L00 Unit Size (Nominal). 48,000 Btuh Voltage' 208/230.1-60 V-Ph-Hz Ent Air DB• 80.00 °F Ent Air WB• 67.00 °F Ent Enthalpy 31.44 BTU/ib Lvg Air DB• 59.59 °F Lvg Air WB• 57.81 °F Lvg Enthalpy 24.91 BTU/Ib Heating Size (Nominal). No Heat Indoor Unit External Static. 0.50 in wg Electrical Data Outdoor Electrical Data Unit Voltage' 460/3 V-Ph-Hz Fan Motor FLA• 0.70 Amps MCA• 8.5 Amps Max Fuse• 10 Amps Operating Range Min• 197 V Operating Range Max. 253 V Compressor RLA• 6.2 Amps Compressor LRA• 41.0 Amps Indoor Electrical Data: (For units with no factory installed electric heaters) Unit Voltage. 208/230-1-60 V-Ph-Hz Unit FLA• 6.0 Amps Unit MCA' 7.5 Amps Unit MOCP. 15.0 Amps Unit Min Wire Size. 14.0 Unit Fuse/Ckt Bkr Amps• 15.0 Amps Motor HP* 3/4 HP Notice: Indoor Elect. data is for 208/230-1-60 voltage Accessory Electric Heater Data (Single point power for unit WITH electric heaters) EH Part Number KFCEH2601C10 Electric Heater kW 10.0 kW For 2 wire operation (single circuit): Heater Amps. 36.2/40.0 Amps Heater + Motor MCA. 53.8/58.5 Amps Heater + Motor MOCP. 60/60 Amps Accessory Voltage. 208/230-1-60 V-Ph-Hz The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.19u Page 6 of 13 REVIEWED FOR CODE COMPLIANCE ' APPROVED NOV 0 3 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 26 2015 PERMIT CENTER U u • A Service Logic Company 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT I r CO 0 Z 0 m W Z W COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. e 1 1 REVISION SUBMITTAL SHEET 10/23/15 0 PERMIT SUBMITTAL 9/23/15 `No. Revision/Issue Date f "Drawn By S. TUTHILL 1 Date SEPTEMBER 23, 2015 Lead Tech Engineered By N. SINGER Date N. 1 5053 Sheet M3.0 [Project roject Manager . SINGER cale AS NOTED