Loading...
HomeMy WebLinkAboutPermit M15-0132 - CORNER BAKERY - TENANT IMPROVEMENTCORNER BAKERY 393 STRANDER BLVD M15-0132 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2623049064 393 STRANDER BLVD Project Name: CORNER BAKERY MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: M15-0132 1/15/2016 7/13/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: REGENCY CENTERS LP PO BOX 790830 C/O PROPERTY TAX DEPT, SAN ANTONIO, IL, 78279 ROBERT CHANDLER 135 LASALLE ST, STE 3100, CHICAGO, IL, 60603 EVERGREEN REFRIGERATION LLC 727 S KENYON ST, SEATTLE, WA, 98108 EVERGRL882JB 1 I 1 Phone: (312) 262-2286 Phone: (206) 763-1744 Expiration Date: 4/2/2016 DESCRIPTION OF WORK: TENANT IMPROVEMENT. EXISTING TENANT ZOOPAS RESTAURANT. NO CHANGE IN OCCUPANCY Valuation of Work: $53,000.00 Type of Work: NEW Fuel type: GAS Fees Collected: $905.98 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: AI Date, 14_ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: \ ((s I This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 4: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ***MECHANICAL PERMIT CONDITIONS*** 12: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 13: Manufacturers installation instructions shall be available on the job site at the time of inspection. 14: Type 1 Hoods, the required grease duct leakage test and (light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. 15: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 16: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 17: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 18: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 19: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 20: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 21: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 22: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 23: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire -extinguishing system installed in accordance with this code. (IFC 904.2.1 and IFC 904.11) Automatic fire -extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 24: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 25: All new automatic fire -extinguishing systems and all modifications to existing automatic fire -extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 26: Local U.L. central station supervision is required. (City Ordinance #2437) 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 28: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 29: Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 30: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 31: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 32: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 33: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.ROV Mechanical Permit No. M15.0132 Project No. Date Application Accepted: 10/9/15 Date Application Expires: 4/9/16 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 2623049064 Site Address: 393 Strander Blvd. Suite Number: A Floor: Tenant Name: Corner Bakery Cafe PROPERTY OWNER Name: Regency Centers Address: 5355 SW Meadow Rd., Suite 295 City: Lake Oswego State: OR zip: 97503 CONTACT PERSON — person receiving all project communication Name: Robert Chandler (Stantec Architecture) Address: 135 S LaSalle St, Suite 3100 City: Chicago State: IL Zip: 60603 Phone: (312) 262-2286 Fax: (312) 262-2301 Email: Robert.Chandler@stantec.com New Tenant: m Yes ❑ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: tbd Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Tenant improvement for proposed restaurant at the end cap unit in an existing single story strip mall. Previous tenant was Zoopas and space has been re -demised. 53,000 Use: Residential: New ❑ Replacement El Commercial: New Replacement ❑ Fuel Type: Electric ❑ Gas Other: H:\Applications\Forms-Applications On Line \2011 ApplicationslMechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 1 Furnace >100k btu 3 Floor furnace 0 Suspended/wall/floor mounted heater 0 Appliance vent 0 Repair or addition to heat/refrig/cooling system 0 Air handling unit <10,000 cfm 4 Unit Type Qty Air handling unit >10,000 cfm 0 Evaporator cooler 0 Ventilation fan connected to single duct 0 Ventilation system 0 Hood and duct 2 Incinerator — domestic 0 Incinerator — comm/industrial 0 Unit Type Qty Fire damper 0 Diffuser 44 Thermostat 3 Wood/gas stove 0 Emergency generator 0 Other mechanical equipment 3 Boiler/Compressor Qty 0-3 hp/100,000 btu 0 3-15 hp/500,000 btu 0 15-30 hp/1,000,000 btu 0 30-50 hp/1,750,000 btu 0 50+ hp/1,750,000 btu 0 PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 R 0 RIZED AGENT: Signature: Print Name: Rob Chandler (Authorized Agent) Mailing Address: 135 S LaSalle St, Ste 3100 Date: 10/16/2015 Day Telephone: (312) 262-2286 Chicago IL 60603 City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY I PAID $978.75 EL16-0046 Address: 393 STRANDER BLVD Apn: 2623049064 $72.77 ELECTRICAL $69.30 PERMIT FEE MULTI-FAM/COMM I R000.322.101.00.00 0.00 $69.30 TECHNOLOGY FEE $3.47 TECHNOLOGY FEE I R000.322.900.04.00 0.00 $3.47 M15-0132 Address: 393 STRANDER BLVD Apn: 2623049064 $905.98 MECHANICAL $871.13 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $664.40 PLAN CHECK FEE R000.322.102.00.00 0.00 $174.23 TECHNOLOGY FEE $34.85 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R7381 R000.322.900.04.00 0.00 $34.85 $978.75 Date Paid: Friday, January 15, 2016 Paid By: EVERGREEN REFRIGERATION LLC Pay Method: CHECK 007678 Printed: Friday, January 15, 2016 10:24 AM 1 of 1 INSRKTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Pr ject: Type of Inspections Addres . S 3q Tbt4 Date Called: Special Instructions: Date Wa t d: a.rn. Requester: Phone No: Approved per applicable codes. ElCorrections required prior to approval. to MENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection; fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. tC� INSPECTION RECORD Retain a copy with permit TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Mir-003z Project: (ot Crier bk (.-e_.- , � Ty e of Inspection .. e I vrIT I a Date led: Special Instr ctions: Date Wanted: `-13-- a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: JA- 1-1-0 &c,—D�� Inspector: Date: y-/s- I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSREkl ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr ect: Type of Inspection:_ eloPe_ Address: 7q3 f/T g(J� Date Called. Special Instructions: A.JA Date �Wanted: - ..- (cf . f , a.m. p.m. Requester: Phone No: a Approved per applicable codes. NCorrections required prior to approval. COMMENTS: C V � a (. a ciAkez_fr-c-/ cS A -IA jui (9t(I eS' ( c)L\ Inspector: r.....e__ Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: coke y Pe-ry Type gfjnspection: e Fl Address: 3q? 5 m IS I J� Date Called: Special Instructions. lepti Date W�,a/pte: ll��( x a.m. p.m. Requester: Phone No: Approved per applicable codes. ICorrections required prior to approval. COMMENTS: [r ( . C IAo -- o ' Pp-01/1 de. `' 0 boa (e.Ir- 4J l L/(,) (F env-\-t f z IA D (d doL A-s -,v- )q uil F a, tf co lit .e fARA- lkk ( fcAit. r . Cti rd PP& F curios -1-o S f € 141 -(krxr (d c' K 1--->ifieA Roo 4 /'i ) 076-6 tre: r°r-f l�= 0 co (.p vu) F e, Va 6 V S v (r) f-l' -e, t ( ra t/acA',‘ .b.‘r- v-6vc p€-(7---coi, Inspector: k oatet / REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Protect: (or vier kle=e-o' y Type of Inspection: t tt 0' Arkik(e Address: 360 5frc t c /6(ki d Date Calle ci Special Instructions: �l S� T� ( Date Wanted: �6 l(46 a.m. p.m. Reuester: Phone No: L I Approved per applicable codes. Corrections required prior to approval. • COMMENTS: V7( Inspector: Date:/i� REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. F-C INSPECTION RECORD ( Retain a copy with permit CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr�%oj�ect: `,, CYrI*` 6T r/ Type of�Inspection;� k6t /t =:-4 Address:� 1(u� Date Call 5 Special I"nstronw p ���V � 5'gft'✓I /ram' 1 9p(vo k� Date Wanted: a.m. P.m. Requester: Phone No: ElApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: Date: _ Z3 / 6) REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (6C INSPECTION RECORD Retain a copy with permit PECi10N NO. PERMIT NO. Mo--6/3 Z CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 L. (q� f �" Pr ject: Corker 6aY-k-p y Type of In ect' n: Att. � C sy W Address: 313 �t 6(�d Date Called: pe Sal Instructions: �A /" 1 Dateant d: � l a.m. p.m. Re nester: ``ww VtAINVot PhoVb''v- q-Y1 73-2- Approved per applicable codes. D Corrections required prior to approval. CO MENTS: inspector: Date: 3 - (4, REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. I INSPECTION RECORD 1 Retain a copy with permit OCTION.NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: /3A 16-e-17 Type of Inspectior?. k --r--fx_ AA Address.CDateff 3”5.'kaler.6II/4 Date Call Special Instructions: �� Date Wanted: 3 `3 -I P a.m. p.m. Requester: PhonetJ i es -713 g(C/3 nApproved per applicable codes. IJ Corrections required prior to approval. COMMENTS: Cc(1 -ti- fre..r Inspector: pate: 3 _ 3 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. 2,1 INSPECTION RECORD Retain a copy with permit M 6I3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 k...1 Pr�° ect: CArt/L ga c-- Type of Inspection" r e( fide d 'I r Address: 3q.st� / eK6114 Date Cod: Special Instructions: n d` Date Wanted 3 5p.m. ^ /4 a.m. Requester: Phone No: Approved per applicable codes. kl- te-17 Kot Off' COMMENTS: Corrections required prior to approval. Qir✓t° 'OD r( tre_ 0,‘ inspector: Dater —16 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit iNSPEC TIN NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter 8ivd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 (J-o(3 z, Pro ect: P®te-•.e tky Type of Inspection.- Pie d4 r u I Adele s: , W � Date alle Special Instructions: A� Date Want : "'_(C a.m. p.m. Requester: Phone No: D Approved per applicable codes. Corrections required prior to approval. COMMENTS:. G1 mv' Inspector: rc, Dater REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Protect: Ty afInsiectic;n: / A5.7 3: P 614 «deeSpecial Date Ca d: Instructions: WI • Date Wanted: 2,- //4 a.rn. p.m. _ Requester: Phone No: A proved per applicable codes. n Corrections required prior to approval. CO MENTS: Inspector: Date: - .`/6 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Inspection: Address: s t::13 , Suite #: ram,.,,,r g( No Contact Person: Special Instructions: Phone No.: . Approved per applicable codes. Corrections required prior to approval. COMMENTS: +A6o& .)-- v..` t -cS\ -.k oE. s \ -iota ,..) 0,1 Br 4, t\--e�s `it) s v ,� t . --_L_cn eZ r r a, e 1C a r C-O0,C\r5 QVL;.✓‘ cryr U" VAC50 1C (-yr,I1 Not Needs Shift Inspection: \{ e 6 Sprinklers: Y e S Fire Alarm: V`n w•v . Hood & Duct: `-'-e, $ Monitor: p\c c vv. �"-- Pre -Fire: 1-kb Permits: p ‘ A Occupancy Type: . ? Inspector:- -Vvv151 Date: "t nWo Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit 1C 1S -- 2 bc`k !c -S-OTf. INSPECTION NUMBER PERMIT .NUMBERS '-1 CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ( -r) eC k�a Type of Inspection: r , %, av ' C �c y Address: Suite #: D1,3 S- c c,-, r-- 7j(,\LV Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 7 , ,-7-c- ck Cuv."0 cii._ __; D. \--\. -'" Q v l .T^ A. •- __ , v"163 `- cJJv,Yu. ck t c� tt A , P 2 ,N1 Q C. 1%L1 \r, l-.l C-v vn9-1-L- 3 M err -s-?-4 1 w, ? v- rnI 1I- c Needs Shift Inspection: -11'c S- Sprinklers: ir--- s. Fire Alarm: ma4\v zL Hood & Duct: Yc s `, L 3.00 Monitor: A r Y• CAv fr. Pre -Fire: N Permits: Q, A t Occupancy Type: .A Z Inspector: 5i Date:\_1\k(c) Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 irdt 1 COMcheck Software Version 4.0.1 Mechanical Compliance Certificate Project Information Energy Code: Project Title: Location: Climate Zone: Project Type: 90.1 (2007) Standard Corner Bakery Cafe Tukwila, Washington 4c New Construction FILE Construction Site: Owner/Agent: Designer/Contractor: 303 Strander Blvd. Tukwila, WA 98188 Mechanical Systems List Quantity System Type & Description 1 RTU-1 (Single Zone): Heating: 1 each - Central Fumace, Gas, Capacity = 150 kBtu/h Proposed Efficiency = 80.00°/a Et, Required Efficiency = 80.00% Et Cooling: 1 each - Single Package DX Unit, Capacity = 92 kBtu/h, Air -Cooled Condenser, Air Economizer Proposed Efficiency = 12.60 EER, Required Efficiency = 11.00 EER Fan System: FAN SYSTEM 1 I RTU-1 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 3000 CFM, 3.0 motor nameplate hp 1 RTU-2 (Single Zone): Heating: 1 each - Central Fumace, Gas, Capacity = 150 kBtu/h Proposed Efficiency = 80.00% Et, Required Efficiency = 80.00% Et Cooling: 1 each - Single Package DX Unit, Capacity = 92 kBtu/h, Air -Cooled Condenser, Air Economizer Proposed Efficiency = 12.60 EER, Required Efficiency = 11.00 EER Fan System: FAN SYSTEM 2 I RTU-2 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 2 Supply, Constant Volume, 3000 CFM, 3.0 motor nameplate hp REVIEWED FOR CODE COMPLIANCE APPROVED NOV 16 2015 City of Tukwila BUILDING DIVISION 1 RTU-3 (Single Zone): Heating: 1 each - Central Fumace, Gas, Capacity = 150 kBtu/h Proposed Efficiency = 80.00% Et, Required Efficiency = 80.00% Et Cooling: 1 each - Single Package DX Unit, Capacity = 117 kBtu/h, Air -Cooled Condenser, Air Economizer Proposed Efficiency = 12.40 EER, Required Efficiency = 11.00 EER Fan System: FAN SYSTEM 3 I RTU-3 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 3 Supply, Constant Volume, 4000 CFM, 3.0 motor nameplate hp 1 MAU-1 (Single Zone): Heating: 1 each - Central Fumace, Gas, Capacity = 81 kBtu/h Proposed Efficiency = 92.00% Et, Required Efficiency = 80.00% Et Fan System: FAN SYSTEM 4 I MAU-1 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 6 Supply, Constant Volume, 1297 CFM, 1.0 motor nameplate hp 1 WATER HEATER: Gas Storage Water Heater, Capacity: 100 gallons, Input Rating: 199 Btu/h w/ Circulation Pump Proposed Efficiency: 98.50 % Et, Required Efficiency: 80.00 % Et RECEIVED CITY OF TUKWILA OCT 6 0 2015 PERMIT CENTER M19•619)12- Project Title: Corner Bakery Cafe Report date: 10/08/15 Data filename: H:\15153\Calc\CBC South Center Tukwila WA-COMCHECK.cck Page 1 of 12 Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical s stems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Ver ion 1.1 and to %•�,o ` •� mandatory requirements listed in the Inspection Checklist. � 4' ' „st ww so i Name - Title Sig ure 37190NtIVAIT Project Title: Corner Bakery Cafe Report date: 10/08/15 Data filename: H:\15153\Calc\CBC South Center Tukwila WA-COMCHECK.cck Page 2 of 12 COMcheck Software Version 4.0.1 1 Inspection Checklist Energy Code: 90.1 (2007) Standard Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. 90.1 (2007) Standard Plan Review Complies? Comments/Assumptions 4.2.2, Plans, specifications, and/or ■Complies Requirement will be met. 6.4.2 calculations provide all information ❑Does Not [PR2]1 with which compliance can be determined for the mechanical ❑Not Observable systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. 4.2.2, f Plans, specifications, and/or � ■Complies Requirement will be met. 7.4.1 calculations provide all information ■Does Not [PR3]1 with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. :Not Observable ❑Not Applicable 6.7.2.4 Detailed instructions for HVAC ❑Complies Exception: Requirement does not apply. [PR5]1 systems commissioning included on the plans or specifications for projects ❑Does Not [Not Observable >=50,000 ft2. •Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) Low Impact (Tier 3) Project Title: Corner Bakery Cafe Data filename: H:\15153\Calc\CBC South Center Tukwila WA-COMCHECK.cck Report date: 10/08/15 Page 3 of 12 90.1 (2007) Standard Footing / Foundation Inspection Complies? Comments/Assumptions 6.4.3.8 [FO9]3 Freeze protection and snow/ice melting system sensors for future connection to controls. ■Complies Requirement will be met. ■Does Not "Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Corner Bakery Cafe Data filename: H:\15153\Calc\CBC South Center Tukwila WA-COMCHECK.cck Report date: 10/08/15 Page 4 of 12 90.1 (2007) Standard Plumbing Rough -In Inspection Complies? Comments/Assumptions 7.4.3 Service hot-water piping systems ❑Complies Requirement will be met. [PL1]2 insulated. Where piping is installed in or under a slab, verification may need to occur during Foundation Inspection. •Does Not Not Observable ❑Not Applicable 7.4.4.1 Temperature controls installed on ❑Complies Requirement will be met. [PL2]3 service water heating systems ❑Does Not (<=1204F to maximum temperature for intended use). ❑Not Observable ❑Not Applicable 7.4.4.2 Automatic time switches installed to ❑Complies Requirement will be met. (PL3)1 automatically switch off the recirculating hot-water system or heat trace. •Does Not [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Corner Bakery Cafe Data filename: H:\15153\Calc\CBC South Center Tukwila WA-COMCHECK.cck Report date: 10/08/15 Page 5 of 12 Section # & Req.ID Mechanical Rough -In Inspection Plans Verified Value Field Verified Value Complies. Comments/Assumptions 6.4.1.4, HVAC equipment efficiency 6.4.1.5 verified. Non-NAECA HVAC [ME1]2 equipment labeled as meeting 90.1. Efficiency: Efficiency: •Complies EDoes Not ❑ Not Observable ❑Not Applicable See the Mechanical Systems list for values. 6.4.3.4.1 ;Stair [ME3]3 'have and elevator shaft vents motorized dampers that automatically close. •Complies Requirement will be met. ❑Does Not ■Not Observable ■Not Applicable 6.4.3.4.2, Outdoor air and exhaust systems 6.4.3.4.3, ,have motorized dampers that 6.4.3.4.4 automatically shut when not in [ME4]3 I use and meet maximum leakage rates. Check gravity dampers ;where allowed. sOComplies i❑Does 1■Not Not ❑Not Observable Requirement will be met. Applicable 6.4.3.4.5 [ME5]3 Ventilation fans >0.75 hp have automatic controls to shut off fan when not required. 1❑Complies ,❑Does Not ['Not Observable ❑Not Applicable Requirement will be met. 6.4.3.9 [ME6]1 Demand control ventilation provided for spaces >500 ft2 and >40 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. •Complies Exception: Systems with a design outdoor airflow less than 1200 cfm. ❑Does Not ❑Not Observable ❑Not Applicable 6.4.4.1.1 Insulation exposed to weather [ME7]3 protected from damage. Insulation outside of the conditioned space and associated with cooling systems is vapor retardant. . ;Complies 1 Requirement will be met. ❑Does Not ❑Not Observable ❑Not Applicable 6.4.4.1.2 [ME8]2 HVAC ducts and plenums insulated. R- R- ❑Complies EDoes Not ENot Observable ❑Not Applicable Requirement will be met. 6.4.4.1.3 [ME9]2 HVAC piping insulation thickness. in. in. •Complies •Does Not Requirement will be met. ['Not Observable ❑Not Applicable 6.4.4.2.1 [ME10]2 Ducts and plenums sealed based on static pressure and location. •Complies Requirement will be met. •Does Not [Not Observable ❑Not Applicable 6.4.4.2.2 [ME11]3 I Ductwork operating >3 in. water column requires air leakage testing. ■Complies Requirement will be met. •Does Not [Not Observable ❑Not Applicable 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. '❑Complies •Does Not •Not Observable •Not Applicable Requirement will be met. 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. •Complies Requirement will be met. :■Does Not •Not Observable ■Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Corner Bakery Cafe Data filename: H:\15153\Calc\CBC South Center Tukwila WA-COMCHECK.cck Report date: 10/08/15 Page 6 of 12 Section # & Req.ID Mechanical Rough -In Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 6.4.4.2.2 Ductwork operating >3 in. water ❑Complies Requirement will be met. [ME11]3 column requires air leakage testing. ❑Does Not ❑Not Observable ■Not Applicable 6.5.1, Air economizers provided where •Complies 6.5.1.1.1, required, meet the requirements `❑Does Not 6.5.1.1.2, for design capacity, control 6.5.1.1.3, signal, ventilation controls, high- ❑Not Observable 6.5.1.3 limit shut-off, integrated Not Applicable [ME12]1 economizer control, and provide a means to relieve excess outside air during operation. 1 6.5.1, Air economizers provided where ❑Complies 6.5.1.1.1, required, meet the requirements •Does Not 6.5.1.1.2, 6.5.1.1.3, for design capacity, control signal, ventilation controls, high- ■Not Observable 6.5.1.3 limit shut-off, integrated ❑Not Applicable [ME12]1 economizer control, and provide a means to relieve excess outside air during operation. 6.5.1, Air economizers provided where ;❑Complies 6.5.1.1.1, required, meet the requirements ❑Does Not 6.5.1.1.2, for design capacity, control 6.5.1.1.3, signal, ventilation controls, high ENot Observable 6.5.1.3 limit shut-off, integrated ,❑Not Applicable [ME12]1 economizer control, and provide a means to relieve excess outside air during operation. 6.5.1.4 Economizer operation will not ■Complies Requirement will be met. [ME16]1 increase heating energy use during normal operation. `❑Does Not ENot Observable ?❑Not Applicable 6.5.1.4 Economizer operation will not ❑Complies Requirement will be met. [ME16]1 increase heating energy use during normal operation. ❑Does Not ENot Observable ❑Not Applicable 6.5.1.4 Economizer operation will not ❑Complies Requirement will be met. [ME16]1 increase heating energy use during normal operation. ❑Does Not ❑Not Observable ❑Not Applicable 6.5.2.3 Dehumidification controls '❑Complies Requirement will be met. [ME19]3 provided to prevent reheating, recooling, mixing of hot and cold airstreams or concurrent heating and cooling of the same airstream. ;❑Does Not ❑Not Observable ❑Not Applicable 6.5.4.1 HVAC pumping systems >10 hp ❑Complies Requirement will be met. [ME25]3 designed for variable fluid flow. ❑Does Not ❑Not Observable ■Not Applicable 6.5.6.1 Exhaust air energy recovery on ❑Complies Exception: Commercial [ME30]1 systems >=5,000 cfm and 70% of design supply air. •Does Not kitchen hoods. ❑Not Observable ❑Not Applicable 6.5.7.1 Kitchen hoods >5,000 cfm have ■Complies Requirement will be met. (ME32]z make up air >=50% of exhaust air volume. ❑Does Not •Not Observable ❑Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Corner Bakery Cafe Data filename: H:\15153\Calc\CBC South Center Tukwila WA-COMCHECK.cck Report date: 10/08/15 Page 7 of 12 Section # & Req.ID Mechanical Rough -In Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 6.5.7.2 Fume hoods exhaust systems ❑Complies Exception: Requirement [ME33]1 >=15,000 cfm have VAV hood exhaust and supply systems, direct make-up air or heat recovery. ❑Does Not does not apply. , ■Not Observable IONot Applicable 6.5.8.1 Unenclosed spaces that are 1LJComplies Exception: Requirement [ME34]3 heated use only radiant heat. :❑Does Not does not apply. ■Not Observable •Not Applicable 6.5.9 Hot gas bypass limited to: <=240 ■Complies Requirement will be met. [ME35]1 kBtu/h - 50% >240 kBtu/h - 25% ,❑Does Not ❑Not Observable ❑Not Applicable 6.5.9 Hot gas bypass limited to: <=240 '❑Complies Requirement will be met. [ME35]1 kBtu/h - 50% >240 kBtu/h - 25% •Does Not ❑Not Observable ❑Not Applicable 6.5.9 Hot gas bypass limited to: <=240 ,❑Complies Requirement will be met. [ME35]1 kBtu/h - 50% >240 kBtu/h - 25% "'Does Not IN Not Observable ❑Not Applicable 7.4.2 Service water heating equipment ''❑Complies [ME36]z meets efficiency requirements. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Corner Bakery Cafe Data filename: H:\15153\Calc\CBC South Center Tukwila WA-COMCHECK.cck Report date: 10/08/15 Page 8 of 12 90.1 (2007) Standard Rough -In Electrical Inspection Complies? Comments/Assumptions 10.4.1 Electric motors meet requirements [EL9)2 where applicable. ❑Complies ❑Does Not ❑Not Observable ❑Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3. Low Impact (Tier 3) Project Title: Corner Bakery Cafe Data filename: H:\15153\Calc\CBC South Center Tukwila WA-COMCHECK.cck Report date: 10/08/15 Page 9 of 12 90.1 (2007) Standard Final Inspection Complies? Comments/Assumptions 6.4.3.1.1 Heating and cooling to each zone is ❑Complies Requirement will be met. [FI2]2 controlled by a thermostat control. ❑Does Not ❑Not Observable ■Not Applicable 6.4.3.1.2, ;Thermostatic controls have a 5 °F •Complies Requirement will be met. 6.4.3.2, Ideadband. ❑Does Not 6.4.3.3, 6.4.3.3.1, ['Not Observable 6.4.3.3.2 ❑Not Applicable [F13]2 6.4.3.7 ,When humidification and •Complies Requirement will be met. (FI6]3 ,dehumidification are provided to a zone, simultaneous operation is prohibited. ■Does Not ❑Not Observable ❑Not Applicable 6.7.2.1 Furnished HVAC as -built drawings ■Complies Requirement will be met. [F17]3 submitted within 90 days of system acceptance. ❑Does Not ❑Not Observable ❑Not Applicable 6.7.2.2 Furnished O&M manuals for HVAC ❑Complies Requirement will be met. [F18]3 systems within 90 days of system acceptance. ❑Does Not •Not Observable ❑Not Applicable 6.7.2.3 An air and/or hydronic system •Complies Exception: Requirement does not apply. [F19]1 balancing report is provided for HVAC systems serving zones >5,000 ft2 of ❑Does Not ;conditioned area. Not Observable ❑Not Applicable 6.7.2.4 HVAC control systems have been ❑Complies Requirement will be met. [FI10]1 tested to ensure proper operation, calibration and adjustment of controls. ❑Does Not • Not Observable ❑Not Applicable 7.4.4.3 Public lavatory faucet water ❑Complies Requirement will be met. [F111]3 temperature <=110°F. ❑Does Not ['Not Observable ❑Not Applicable 7.4.4.4 'Controls are installed that limit the ❑Complies Requirement will be met. [F112]3 loperation of a recirculation pump installed to maintain temperature of a storage tank. ❑Does Not Not Observable 1 ❑Not Applicable 6.4.3.2 Temperature controls have setpoint ■Complies Requirement will be met. [F120]1 overlap restrictions. ■Does Not •Not Observable ❑Not Applicable 6.4.3.3.1 HVAC systems equipped with at least ■Complies Requirement will be met. [F121]1 one automatic shutdown control. ■Does Not ■Not Observable ❑Not Applicable 6.4.3.3.2 Setback controls allow automatic '•Complies Requirement will be met. [F122]1 restart and temporary operation as ❑Does Not required for maintenance. [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Corner Bakery Cafe Data filename: H:\15153\Calc\CBC South Center Tukwila WA-COMCHECK.cck Report date: 10/08/15 Page 10 of 12 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Corner Bakery Cafe Data filename: H:\15153\Calc\CBC South Center Tukwila WA-COMCHECK.cck Report date: 10/08/15 Page 11 of 12 Project Title: Corner Bakery Cafe Report date: 10/08/15 Data filename: H:\15153\Calc\CBC South Center Tukwila WA-COMCHECK.cck Page 12 of 12 HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0132 DATE: 10/20/15 PROJECT NAME: CORNER BAKERY SITE ADDRESS: 393 STRANDER BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) REVIEWER'S INITIALS: DATE: 10/20/15 Structural Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/17/15 Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: Si-4-ex-0 ✓\ M33 •s/ REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/ I R/2013 EVERGREEN REFRIGERATION LLC Page 1 of 3 Home Inicio en ..Espanol Contact A-Z Index Help My Secure t. I Safety Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries EVERGREEN REFRIGERATION LLC Owner or tradesperson Principals PATTON, DOUGLAS, PARTNER/MEMBER PATTON, ROGER, PARTNER/MEMBER PATTON, MATTHEW, PARTNER/MEMBER PATTON, ADAM, PARTNER/MEMBER Doing business as EVERGREEN REFRIGERATION LLC WA UBI No. 602 512 953 727 S KENYON ST SEATTLE, WA98108 206-763-1744 KING County Business type Limited Liability Company Governing persons DAVID A PATTON MATTHEW PATTON; RODGER PATTON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ........_........_..................................... Meets current requirements. License specialties GENERAL License no. EVERGRL882JB Effective — expiration 04/02/2012— 04/02/2016 Designated administrator ................. Jones, Anthony License type Electrical Administrator Bond Merchants Bonding Co (Mutual) Bond account no. WA31802 Active. Meets current requirements. License no. JONESA*909RC $4,000.00 Received by L&I Effective date 07/10/2012 04/07/2012 Expiration date Until Canceled Bond history Savings .............. ... No savings accounts during the previous 6 year period. License Violations https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602512953&LIC=EVERGRL882JB&SAW= 1/15/2016 MECHANICAL NOTES BY SYM BOL MX PRINT DATE: Oct 08, 2015 - 11:45am L 1 J EF-2 RTU-3 COOLER -CONDENSER FREEZER -CONDENSER 11+4" (150 CFH 1" (8 MAU CFH) 420 L_ J J SALAD-CONEDNSER 21/2" (1,154 CFH) 11/2" (300 CFH) ffXPO-CONEpENSER I\I L RTU-2 8 E"). RTU-1 • /4" (150 CFH) 0 er„...„---1114" (10 CFH) 1112" (300 CFI -I) 11 11 11 1 11 1 II / II II i \ II -ZEE -11MIE SIZE AS INDICAIfED ON PLAN MINIMUM 6" DIRT LEG :PP RATE PERMS=f '` REQUIRED FOR: Q Attechartic,a1 a'Electricat ePfumbing iGas Piping City of Tukwila BUILDING DIVISION v RE'VlSIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. UNION MINIMUM 3" CL RANCE BETWEEN DIR LEG AND ROOF GAS -COCK PLAN MECHANICAL ROOF PLAN SCALE: NTS FILE COPY Permit No. 3z P lan review approval is subject to errors and omissions. pproval of construction documents does not authorize e violation of any adopted code or ordinance. Receipt approved Field Copy and conditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION PIPING CADDY ON ROOF RTU GAS PIPING CONNECTION SCALE: NTS 5.5 PIPE CADDY ROOF ROOFTOP UNIT CONDENSATE PIPING CONNECTION SCALE: NTS 1. NEW ROOF MOUNTED GREASE EXHAUST FAN AND MAKE UP AIR UNIT, CURB FURNISHED BY OWNER & INSTALLED BY MECHANICAL CONTRACTOR. INSTALL A MINIMUM OF 10' FROM INTAKE FLUES. REFER TO KITCHEN EXHAUST FAN SCHEDULE, HOOD DETAILS AND MANUFACTURERS PRODUCT MANUALS FOR ADDITIONAL REQUIREMENTS AND INFORMATION. 2. NEW ROOF MOUNTED EXHAUST FAN AND CURB FURNISHED BY OWNER & INSTALLED BY MECHANICAL CONTRACTOR. INSTALL A MINIMUM OF 10' FROM INTAKE FLUES. REFER TO EXHAUST AND VENTILATION FAN SCHEDULE FOR ADDITIONAL REQUIREMENTS. 3. CONCENTRIC GAS FLUE & AIR INTAKE THRU ROOF. REFER TO M101 AND DETAIL 2/P311. 4. FACTORY INSTALLED DUCT SMOKE DETECTOR IN THE SUPPLY AIR DUCT FOR AUTOMATIC SHUT DOWN OF FAN. WIRING AND CONNECTION TO FIRE ALARM SYSTEM BY FIRE ALARM CONTRACTOR. SMOKE DETECTORS SHALL BE LABELED FOR INSTALLATION IN ROOF TOP UNITS SUPPLY AIR DUCT AND INSTALLED IN ACCORDANCE WITH NPFA 72. REFER TO SHEET E304 FOR SMOKE DETECTOR INTERLOCK WITH THE HOODS AND ROOF TOP UNITS. 5. NOT USED. 6. RESTROOM EXHAUST FAN EF-2 SHALL BE CONTROLLED VIA TIMECLOCK. 7. INTERCONNECT EXHAUST FAN EF-1/MUA-1 WITH THE KITCHEN HOODS H-1 AND H-2. CONNECT FANS PER MANUFACTURER'S REQUIREMENTS AND SHOP DRAWINGS. SEE SHEET M202 & E304 FOR ADDITIONAL INFORMATION. 8. APPROXIMATE COOLER/FREEZER CONDENSER LOCATION. COORDINATE REQUIRED ARRANGEMENT WITH OWNER. REFER TO E111 FOR ELECTRICAL REQUIREMENTS AND KITCHEN DRAWINGS FOR ADDITIONAL INFORMATION. 9. 4" SANITARY VENT THRU ROOF. LOCATION OF VENT THROUGH ROOFS SHALL BE LOCATED AT LEAST 10 FEET FROM ANY FRESH AIR INTAKES. 10. CONDENSATE FROM ROOF TOP UNITS SHALL DRAIN ONTO ROOF IF ALLOWED BY CODE. IF NOT ALLOWED, CONDENSATE SHALL BE ROUTED TO THE NEAREST PROPER PLUMBING FIXTURE AND BE DISCHARGED TO THE SANITARY SEWER. SLOPE CONDENSATE LINES AT MINIMUM OF 1/8" PER FOOT. 11. NOT USED. 12. REFRIGERANT PIPE THRU ROOF PENETRATION FOR REMOTE CONDENSING UNITS. - FURNISHED BY OWNER, INSTALLED BY MECHANICAL CONTRACTOR. REFER TO DETAIL 04/PME1 13. TENANT CONTRACTOR TO COORDINATE NEW GAS METER AND GAS SERVICE WITH GAS COMPANY. EXISTING GAS METER MANIFOLD LOCATED APPROXIMATELY 70' SOUTH OF DEMISING WALL. TOTAL GAS DEMAND IS 1,154 CFH. 14. PROVIDE ERICO PYRAMID EQUIPMENT SUPPORT. REFER TO DETAIL 03/M301. 15. GAS DOWN THROUGH ROOF. REFER TO SHEET P111 FOR CONTINUATION. 16. NOT USED. 17. REFRIGERATOR CONDENSER: REFER TO THE MANUFACTURER'S SHOP DRAWINGS FOR EXACT INSTALLATION AND INTERCONNECTION REQUIREMENTS. SEE SHEET E111 FOR THE LOCATION OF THE EQUIPMENT SERVED IN THE KITCHEN. 18. REFRIGERANT PIPE CHASE BELOW FOR THRU ROOF PENETRATION OF REMOTE CONDENSING UNITS; REFER TO FLOOR PLAN ON SHEET A101 FOR WALL CHASE LOCATION & KITCHEN DRAWINGS FOR DETAILS. MECHANICAL GENERAL NOTES: A. B. C. D. E. F. TERMINATE ALL PLUMBING VENTS AND EXHAUST FANS A MINIMUM OF 10'-0" FROM OUTDOOR AIR INTAKES ON THE ROOFTOP UNITS. APPLIANCE VENTS SHALL NOT BE CLOSER THAN 4'-0" FROM VERTICAL WALLS. ALL NEW ROOFTOP EQUIPMENT SHALL BE SET ON FACTORY CURBS AND PROPERLY FLASHED. RE -USE EXISTING ROOF OPENINGS WHERE POSSIBLE, PROVIDE ADAPTIVE CURBS IF NEEDED. AS APPLIES, CONTRACT DIRECTLY WITH LANDLORD'S ROOFING CONTRACTOR FOR ALL ROOF WORK. NO PERMANENT ATTACHMENTS SHALL BE MADE TO ROOF WITHOUT LANDLORDS CONSENT. CONDENSATE AND REFRIGERANT LINE PENETRATIONS SHALL BE FLASHED/SEALED ACCORDING TO LANDLORD'S ROOFING CONTRACTOR AND PER AHJ REQUIREMENTS. UTILIZE RTU CURB OPENING OR EXISTING PENETRATIONS WHERE POSSIBLE. ALL EQUIPMENT SHALL BE LABELED OR LISTED BY A RECOGNIZED APPROVAL AGENCY. REFER TO MECHANICAL AND PLUMBING SYMBOLS LEGEND. ALL ROOFTOP EQUIPMENT (REFRIGERANT EQUIPMENT, EXHAUST FANS AND ROOF TOP UNITS) TO BE LABELED WITH NAME PLATES INDICATING EQUIPMENT NUMBERS AND "CORNER BAKERY", FOR SERVICE IDENTIFICATION. PROVIDE MACHINE ETCHED "BAKELITE" IDENTIFICATION NAME PLATES, HAND ETCHING IS NOT ACCEPTABLE. G. REFER TO SPECIFICATIONS FOR MATERIALS AND METHODS FOR CONSTRUCTION. H. ARRANGE WITH AUTHORITIES AND UTILITY COMPANIES FOR PERMITS, FEES, AND SERVICE CONNECTIONS. VERIFY LOCATIONS AND ARRANGEMENTS AND PAY ALL CHARGES, INCLUDING INSPECTIONS. I. ALL ITEMS PROJECTING THROUGH ROOFS SHALL BE FLASHED THROUGH CURBS OR PIPE SEALS A MINIMUM OF 12" ABOVE THE ROOF. INSURE THAT AMPLE BOOT OPENINGS ARE PROVIDED TO ACCOMMODATE ANY ELECTRICAL CONDUIT PENETRATIONS REQUIRED. FAN DISCONNECT SWITCH (NIC) SEAL CONNECTOR WEATHERPROOF JUNCTION BOX. MOUNT TO SIDE OF METAL CURB AS SHOWN. RIGID CONDUIT RUNNING INSIDE CURB, UP TO WEATHERPROOF J-BOX. JUNCTION BOX AT FAN CURB SCALE: NTS PIPING PENETRATION ASSEMBLY TO BE MANUFACTURED BY: 15" SQ. 6" 12" SQ. 18" NOTE: ALL GAS LINES, CONDENSATES & REFRIGERATION LINES TO BE SECURED TO ROOF SUPPORTS W/APPROVED METAL CLAMPS OR ATTACHMENT DEVICES. ROOF SUPPORTS TO COMPLY W/ ROOFING MANUFACTURERS SPECIFICATIONS. NO NYLON, PLASTIC ZIP TIES OR TAPE WILL BE ALLOWED FOR EXTERIOR APPLICATIONS. G.C. TO PROVIDE SUPPORTING DOCUMENTATION AS PART OF THE CLOSEOUT PACKAGE. NOTE: FURNISHED BY OWNER, INSTALLED BY MECHANICAL CONTRACTO FAN LOCKING ASSEMBLY DUCT WRAP GREASE DUCT ENCLOSURE ROOF CURB WITH APPLIED ROOFING MATERIAL (DO NOT MAKE ANY PENETRATIONS THROUGH CURB) -6" MIN. THYCURB 2305 BELTLINE RD. SUITE 180 CARROLLTON, TX. 75006 1-800-777-CURB REVIDAWED FOR CODE COMPLIANCE APPROVED NOV 1 6 2015 City Of TAwila BUILDING PIVISi06 STANDARD FEATURES 1. FACTORY INSTALLED 2x6 WOOD NAILER 2. WELDED 18 GA. GALVANIZED STEEL SHELL AND BASE PLATE 3.1112" THICK, 3-LB RIGID CURB INSULATION 4. 1" CAP INSULATION 5.314" WELDING FLANGE 6.20 GA. COUNTERFLASHING CAP ADDED OPTIONS 1. 6" OVERHANG 2. 18" HEIGHT 3.2" FLANGE THY -CURB TC-3 WITH TP-2 PIPING COVER SCALE: NTS Stantec Architecture Inc. 1383 North McDowell Blvd., Suite 250 Petaluma CA 94954 .stantec.com 0 0 U 0 0 O 0. -▪ 0 0 -2 0 c 0 O • U -c - a)c o0 a- a)a ▪ D m 2 .� 0 0 m j 0 0 -oc o-• c 0 m L_ N 0 -0 a) o � O Q 0- • c 0 00 U a) a) 1-0 Engineers, Inc. 760 Creel Drive Wood Dale, IL 60191 Tel. 630/595-8800 Fax 630/595-8818 www.WCWengineers.com NO REVISION ISSUED FOR PERMIT 10/08/2015 & BID EXPIRES Expiration Date RECEIVED CITY OF TUKWILA OCT 0 9 2015 PERMIT CENTER DRAWN BY: CW 10/05/2017 CHECKED BY: SK PROJECT NUMBER 2007855013 NUMBER Utility Roof Plan DATE OF THIS PRINTING - Oct 08, 2015 PRINT DATE: Oct 08, 2015 - 11:45am CENTER PAD BELOW PIPE STAND MIRO MODEL PAD 16 3/4"X19 314°X1/8" MIRO INDUSTRIES PILLOW BLOCK MODEL #5-RAH PIPESTAND GAS PIPE SIZE AS REQUIRED PILLOW BLOCK PIPE STAND MIRO MODEL PAD 16 314°X19 3147118' ROOFING MATERIAL ELEVATION PIPE STAND GOOD FOR 112' TO 5' STEEL PIPE SIZES ONLY. HOUSE GAS SUPPORT GAS PIPE SIZE AS REQUIRED. SEE DRAWINGS. PROVIDE PROTECTIVE COATING; PRIME PIPE AND FITTINGS WITH A COMPATIBLE PRIMER PRIOR TO APPLICATION OF PAINT. PROVIDE LUSTERLESS ALKYD ENAMEL PRIMER SHALL BE SYNTHETIC RUST -INHIBITING PRIMER. PROVIDE TWO (2) COATS LUSTERLESS ALKYD ENAMEL. COLOR SHALL BE GREEN UNLESS OTHERWISE REQUIRED BY LOCAL AUTHORITY. PROVIDE ALUMINUM PIPE STRAPS. FASTEN TO PIPE STAND PER MANUFACTURERS SPECIFICATIONS PIPE SHALL REST FIRMLY ON PIPE STAND WITHOUT GAPS PIPE STANDS ARE ADJUSTABLE FOR PROPER ELEVATION OF VARIOUS SIZE PIPE TO MAINTAIN LEVEL PIPING. NO SHIMS OR BLOCKS ARE PERMITTED MAXIMUM SPACING FOR GAS PIPE SUPPORTS STEEL PIPE SIZE (NPS) SPACING IN FEET MIN. ROD SIZE - INCHES (HORIZONTAL) 1/2° 6' O.C. 3/8" 3/4"TO1° 8'O.C. 3/8° 11/4" AND LARGER 10' O.C. 1/2° (VERTICAL) 3 112"TO 5" EVERY FLOOR GAS PIPE SUPPORT ON ROOF SCALE: NTS SECURE FAN TO CURB WITH GALV. SHT. MTL. SCREWS CURB GASKET BACKDRAFT DAMPER BOTTOM END CAP SEALED WATER TIGHT 114" THICK NEOPRENE GASKET 2 x 4 WOOD NAILER CURBS WILL BE WELDED TO STRUCTURE BY GENERAL CONTRACTOR RUSKIN MODEL NO. BD2/A2 DAMPER LOCATION, IF REQUIRED MOUNTING FLANGE 18 GA. G.I. DUCT RISER .. iS111111111111111111111111111111111 ROOF EXHAUST FAN ISEE DETAIL 02IPME2 :...e\I 1 I FLEXIBLE CONNECTION OOF JOIST ie..A�°�BRANCH DUCT TAP ROOF FAN DETAIL SCALE: NTS INSULATION & ROOFING FABRICATED CURB CAP, 18 GA. G.I. (MIN.) COUNTER FLASHING OR EQUIPMENT BASE. FASTEN TO WOOD NAILER WITH SCREWS @ 6" O,C. CANT MIN 12" ROOF INSULATION \ / ANGLE FRAME SECURED TO STRUCTURE SHEET METAL SCREWS, 6" O.C. METAL DECK ROOF JOIST NOTES: 1. CURB SHALL BE TAPERED TYPE AND MATCH THE PITCH OF THE ROOF. 2. SECURELY INSTALL CURB TO ROOF STRUCTURE; USE FASTENERS AS REQUIRED BY ROOF CONSTRUCTION. *PREFABRICATED ROOF CURB SCALE: NTS SCALE: NTS 0 (_. 1 10-3/8" ERICO PYRAMID 50 ERICO CADDY PYRAMID 50 WITH HOT DIPPED GALAVANIZED (P1) FINISH. REFER TO MANUFACTURER FOR INSTALLATION INSTRUCTIONS SUPPORT FOR CONDUIT, CONDENSATE, AND REFRIGERATION LINES PIPE SUPPORT ON ROOF SCALE: NTS FOAM FILLED VOID AND SILICONE SEALED • • #10 LARGE SCREWS @ 24" O.C. MAX. @i) 24 GA. GALVANIZED SHEET METAL HOOD REFRIGERANT LINE SLOPE DOWN FROM HOOD 26 GA. COUNTERFLASHING \\.,..................--- ROOF FELTS & FLASHING 12" MIN. REFRIGERATION ROOF PENETRATION SCALE: NTS REVIEWED FOR CODE COMPLIANCE, I APPROVED Stantec Architecture Inc. 1383 North McDowell Blvd., Suite 250 Petaluma CA 94954 .stantec.com 0 0 M -0 ,. Z t U O o o 0 0 O a) o C 0 .0 o a) 0 a i` a)c E 2 ) U N Q T 0 t 0 -0 a a O E °'_ • oL c— 0 0 0 3 0 aN O p CS C -0 .� 0) 0 a c 0 0 0 c E 0 O 0 C a) 2 o 2)-c 0 Q • 0 H c • o H a t c 0 • _c •� 0 `c 3 a O 0 0 U-0U3 a) ▪ a) 0 D Engineers, Inc. 760 Creel Drive Wood Dale, IL 60191 Tel. 630/595-8800 Fax 630/595-8818 www.WCWengineers.com PROTOTYPE 5.2.13 NO REVISION ISSUED FOR PERMIT & BID 10/08/2015 j Date ;52 Y40108/2015 EXPIRES om512o, Expiration Date iECEiVED CITY OF TUKWILA OCT 0 9 2015 0 CO 06 W 0_ 0 U. 0 W (1) (1) N CO 0 O PERMIT CENTER DRAWN BY: CW CHECKED BY: SK PROJECT NUMBER 2007855013 SHEET NUMBER NOV 16 2015 City of Tua �Arila BUILDIN( DIVISION Roof Details DATE OF THIS PRINTING - Oct 08, 2015 PRINT DATE: Oct 08, 2015 PLAN G1-S G1-S G1-S Vint G1-S MECHANICAL FLOOR PLAN SCALE: 1/4" = 1'-0" G1-S G -S G1-S Ci-S SINGLE LINE DESCRIPTION DOUBLE LINE 90° LONG RADIUS ELBOW DOWN ( C ) 90° LONG RADIUS ELBOW UP C ) ---0 ROUND RADIUS ELBOW SPIN -IN FITTING WITH (RECTANGULAR TODAMPER ROUND) - 4. ---Ito— CONCENTRIC TRANSITION i b' ECCENTRIC TRANSITION i RECTANGULAR TO ROUND TRANSITION OR EXISTING TRANSITION �� -� 90° RECTANGULAR ELBOW DOWN + 1 EX] 90° RECTANGULAR ELBOW UP 4- IN 0 , ELBOW Jr- %RADIUS _ SPLIT BRANCH TAKE -OFF WITH SQUARE ELBOW MEDIUM PRESS.ir-- DUCT4- T ���� SPLIT BRANCH TAKE -OFF WITH RADIUS ELBOW MEDIUM PRESS. DUCT + 6 + JBRANCH TAKE -OFF RETURN OR EXHAUST Jr 1 Jr TWO SIDED TRANSITION (RECTANGULAR DUCT) jr , —� _1110— ONE SIDED TRANSITION (RECTANGULAR DUCT) \_� FLEXIBLE DUCT I I I I 1 I MECHANICAL SYMBOLS SYMBOLS DESCRIPTION CAPPED OR PLUGGED PIPE BLIND FLANGE I CONCENTRIC REDUCER OR INCREASER —D ECCENTRIC REDUCER OR INCREASER - BOTTOM FLAT ECCENTRIC REDUCER OR INCREASER - TOP FLAT v I-- UNION I Q THERMOSTAT (HEIGHT NOTED) O REMOTE COMBINATION HUMIDITY AND TEMPERATURE SENSOR 4- MANUAL BALANCING DAMPER SOIL,WASTE OR SANITARY SEWER SANITARY VENT — COLD WATER HOT WATER (110°) HOT WATER RECIRCULATING — - - - -140° - - HOT WATER (TEMPERATURE °F NOTED) -140° - - -- HOT WATER RECIRCULATING (TEMPERATURE °F NOTED) INDIRECT DRAIN FIRE LINE (WET) HEAT TRACED PIPE GATE VALVE —1><1 GLOBE VALVE BUTTERFLY VALVE �IQ mil— CHECK VALVE b BALL VALVE --I I-- WATER BALANCING COCK i a I--[ BALL VALVE WITH 3/4" HOSE THREAD ADAPTER _1 p;(1 PRESSURE REDUCING VALVE TEMPERATURE AND PRESSURE RELIEF VALVE A SOLENOID VALVE GAS PRESSURE REGULATOR —O SUPPLY AIR GRILLE (ARROWS INDICATE AIR THROW DIRECTION) (NO ARROWS SHOWN INDICATES 4 WAY THROW) �;� ~ RETURN AIR GRILLE GENERAL NOTES A. CONTRACTORS AND SUBCONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY DETERMINED WITHOUT REFERENCE TO THE COMPLETE DOCUMENT SET. B. COORDINATE WITH THE WORK OF OTHER SECTIONS, EQUIPMENT FURNISHED BY OTHERS, REQUIREMENTS OF THE OWNER, AND WITH THE CONSTRAINTS OF THE EXISTING CONDITIONS OF THE PROJECT SITE. PROVIDE DUCT RISES AND DROPS AS REQUIRED FOR FIELD INSTALLATION AND TRADE COORDINATION. NOTIFY OWNER OF ANY DISCREPANCIES BEFORE STARTING WORK. C. DRAWINGS FOR HVAC WORK ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, LAYOUT, AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENT. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS. PROVIDE DUCTWORK, CONNECTIONS, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY FOR A COMPLETE SYSTEM. D. ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODE REQUIREMENTS AS APPROVED AND AMENDED BY THE GOVERNING CITY, INCLUDING APPLICABLE SECTIONS OF NFPA, OSHA, UBC, OR ANY INTERIM AMENDMENTS AT THE TIME OF THE PROPOSAL. PURCHASE ALL PERMITS ASSOCIATED WITH THE WORK. OBTAIN ALL INSPECTIONS REQUIRED BY CODE. E. MOUNT PROGRAMMABLE THERMOSTATS AT 48" AFF TO TOP OF CONTROLS ON PLAN. REMOTE SENSORS TO BE MOUNTED IN RETURN AIR DUCTS UNLESS INDICATED OTHERWISE ON PLAN. F. ALL ELBOWS TO BE RADIUS UNLESS SPECIFICALLY SHOWN OTHERWISE. G. INSTALL DUCTWORK TIGHT TO BOTTOM OF STRUCTURE UNLESS SPECIFICALLY SHOWN OTHERWISE. H. ALL VOLUME DAMPERS SHALL BE LOCKING TYPE. I. MECHANICAL CONTRACTOR SHALL VERIFY THAT ALL EQUIPMENT, AS SHOWN ON THESE DRAWINGS, WILL NOT CONFLICT WITH ANY DRAINS, SCUTTLES, JOINTS, VENTS, PIPING OR EQUIPMENT. J. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO RECEIVE, OFF-LOAD, STORE, INSURE, CARRY UP, DISPOSE OF DEBRIS AND SET IN PLACE ALL OWNER FURNISHED ITEMS AND EQUIPMENT. K. ALL SUPPLY AND RETURN DIFFUSERS SHALL BE FINISHED FACTORY WHITE. COORDINATE LOCATIONS WITH LIGHTING FIXTURES. L. CONTRACTOR AND SUBCONTRACTORS SHALL NOT PENETRATE THROUGH HOODS WITH CONDUIT, DUCTWORK, WIRING OR ANY OTHER INSTALLATION THAN FOR THE APPROVED INSTALLATION OF THE HOODS THEMSELVES. M. ALL ROOFTOP EQUIPMENT SHALL HAVE MANUFACTURER SUPPLIED ROOF CURBS AND PIPE SEALS. N. MECHANICAL CONTRACTOR SHALL PROVIDE COMPLETE INFORMATION AND COOPERATION TO THE OTHER CONTRACTORS AND TRADES AS REQUIRED FOR COMPLETION AND COORDINATION OF THE COMPLETE PROJECT. 0. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ADMINISTERING ALL WARRANTIES ON EQUIPMENT WHICH HE INSTALLS. THIS INCLUDES, BUT IS NOT LIMITED TO REFRIGERANT LINES, ETC. P. PROVIDE VIBRATION ISOLATION DEVICES AND FLEXIBLE CONNECTIONS TO ALL MOVING MACHINERY. Q. FLEXIBLE DUCTS SHALL BE ONLY BE USED FOR VERTICAL DROP FROM METAL ELBOW TO DIFFUSER. THE MAXIMUM ALLOWABLE LENGTH OF THE FLEX DUCT SHALL BE 5'-0". FABRICATE AND SUPPORT IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS. R. NO FLEXIBLE DUCTWORK SHALL BE ALLOWED IN EXPOSED CONDITIONS OR ABOVE INACCESSIBLE CEILINGS. S. ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. T. MECHANICAL CONTRACTOR SHALL COORDINATE ALL DUCT AND DIFFUSER LOCATIONS WITH SPRINKLER PIPING, SPRINKLER HEADS AND LIGHTING LAYOUT AS REQUIRED. U. MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR AND OTHER TRADES ALL REQUIRED OPENINGS AND EXCAVATIONS. ALL REQUIRED OPENINGS IN FOUNDATIONS, FLOORS, WALLS AND ROOF SHALL BE CONSTRUCTED INTO THE STRUCTURE WITH THE USE OF SLEEVES, CURBS, ETC. CUTTING AND PATCHING SHALL BE HELD TO A MINIMUM. V. ALL EQUIPMENT SHALL BE LABELED OR LISTED BY A RECOGNIZED APPROVAL AGENCY, W. AIR BALANCING BY OWNER SHALL BE TO THE QUANTITIES SPECIFIED ON THE PLANS IN ACCORDANCE WITH THE LATEST EDITIONS OF THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) PROCEDURAL STANDARDS, OR ASSOCIATED AIR BALANCE COUNCIL (AABC) NATIONAL STANDARDS, AND AS AMENDED BY THESE DOCUMENTS. ALL EF'S SHALL RUN AT THE TIME OF BALANCE. OWNER TO PROVIDE THE TESTING, ADJUSTING, AND BALANCING (TAB) OF THE AIR CONDITIONING SYSTEM. ACCEPTABLE (TAB) COMPANY. THE CONTRACTOR SHALL COORDINATE WITH CBC CONSTRUCTION MANAGER AND PROVIDE A CONSTRUCTION SCHEDULE THAT INCLUDES THE NAME OF THE JOBSITE SUPERINTENDENT AND PHONE NUMBER. ALL SYSTEM SHOULD BE 100% OPERATIONAL PRIOR TO THE TESTING. REFERENCE SPEC SECTION (15990: 1.2 - START-UP, TEST AND ADJUSTMENT) FOR FURTHER INSTRUCTIONS. X. ALL MECHANICAL EQUIPMENT SHALL BE INSTALLED, ANCHORED AND BRACED IN ACCORDANCE WITH LOCAL SEISMIC RESTRAINT REQUIREMENTS. Y. PROVIDE INTERLOCK WIRING BETWEEN ALL AC UNITS AND EXHAUST SYSTEM. WHEN KITCHEN EXHAUST FANS ARE ON, ALL AC UNITS AND SUPPLY FAN SHALL ENERGIZE. THE EXHAUST AND MAKE-UP AIR SYSTEM SHALL BE CONNECTED BY AN ELECTRICAL INTERLOCKING SWITCH. IF FIRE IS DETECTED UNDER HOOD, THEN ALL AC UNITS SHALL SHUT DOWN AND EXHAUST FANS WILL REMAIN ON AS REQUIRED BY LOCAL CODE. Z. 10' MIN. DISTANCE FROM EXHAUST TO OUTSIDE AIR INTAKE. AA. MECHANICAL CONTRACTOR TO PROVIDE ALL CODE REQUIRED FIRE RATED ACCESS DOORS IN GREASE DUCTS AT ALL LOCATIONS REQUIRED PER CODE AND LOCAL AUTHORITY HAVING JURISDICTION. AB. GREASE DUCTS SHALL SLOPE AT A MINIMUM OF 1/4" PER LINEAR FOOT TOWARD HOOD. AC. GC TO CHANGE ALL EXISTING CONSTRUCTION RTU FILTERS AT COMPLETION OF CONSTRUCTION AND BUILDING TURN OVER TO THE OWNER REFER TO SPECIFICATIONS FOR MATERIALS AND METHODS FOR CONSTRUCTION. AD. REFER TO SPECIFICATIONS FOR MATERIALS AND METHODS FOR CONSTRUCTION. AE. ARRANGE WITH AUTHORITIES AND UTILITY COMPANIES FOR PERMITS, FEES, AND SERVICE CONNECTIONS. VERIFY LOCATIONS AND ARRANGEMENTS AND PAY ALL CHARGES, INCLUDING INSPECTIONS. AF. ALL MAIN TRUNK, BRANCH AND ELBOWS ARE TO BE METAL. AG. (OPTIONAL CONDITION) - INTERLOCK EXHAUST FAN EF-2 WITH WAREWASHER WHEN WAREWASHER DOOR IS CLOSED AND WASHING CYCLE BEGINS THEN START THE EXH. FAN. THE FAN SHALL RUN CONTINUOUSLY WHILE WASHING DISHES. WHEN THE WAREWASHER DOOR IS OPENED AT THE END OF THE WASH CYCLE CONTINUE TO OPERATE THE EXHAUST FAN FOR TWO ADDITIONAL MINUTES (ADJUSTABLE DELAY) TO CAPTURE STEAM AND HEAT. AT THE END OF THE DELAY, DE -ENERGIZE THE EXH. FAN. NOTES BY SYMBOL 1. TRANSITION FROM HOOD COLLARS AND EXTEND 20"X16" KITCHEN HOOD GREASE EXHAUST DUCTWORK UP TO EF-1. OFFSET DUCT TO AVOID STRUCTURE. GREASE DUCT SHALL BE WRAPPED WITH TWO (2) LAYERS OF THERMAL CERAMICS DUCT WRAP 2X2, 2" THICK WITH 3" PERIMETER AND LONGITUDINAL OVERLAPS. OR EQUIVALENT U.L. LISTED GREASE DUCT WRAP FOR ZERO CLEARANCE TO COMBUSTIBLES. REFER TO HOOD DETAILS SHEETS M302, M303, M304. 2. NOT USED. 3. NOT USED. 4. 14"x14" EXHAUST DUCT UP THRU ROOF TO EF-2. COORDINATE WITH STRUCTURE FOR LOCATION OF ROOF PENETRATION. 5. EXHAUST HOOD FURNISHED BY OWNER, INSTALLED BY CONTRACTOR. SUPPORT HOOD PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. TRANSITION FROM HOOD CONNECTIONS TO DUCT SIZES SHOWN. REFER TO HOOD DETAILS SHEETS M302, M303, M304. 6. SUPPLY AIR AND RETURN AIR DUCT UP TO ROOF TOP UNIT. REFER TO MECH ROOF PLAN SHEET PM1 FOR CONTINUATION. COORDINATE WITH STRUCTURAL. TRANSITION AS REQUIRED. 7. ENTOUCH ONE MASTER AND SLAVE CONTROLLERS AT 48" A.F.F. PROVIDE REMOTE COMBINATION TEMPERATURE AND HUMIDITY SENSORS. PROVIDE SYSTEM SENSOR #RTS451 SMOKE DETECTOR RESETS UNDER THERMOSTATS, REFER TO ELECTRICAL DWGS FOR MORE INFORMATION. 8. PROVIDE THE "PENETRATOR" GREASE DUCT CLEAN -OUT ACCESS DOORS MANUFACTURED BY FLAME GUARD, INC. AT EVERY CHANGE OF DIRECTION. ACCESS DOOR SHALL BE INSTALLED ON THE SIDE OF THE DUCT IN AN ACCESSIBLE LOCATION. 9. PROVIDE 4" PVC, CPVC, ABS COMBUSTION AND FLUE PIPING TO VENT THROUGH ROOF. FLUE SHALL BE A MINIMUM 10' FROM ANY FRESH AIR INTAKE. PROVIDE CONCENTRIC VENT TERMINATION KIT. VENT AND EXHAUST TERMINAL SHALL BE AT LEAST 12" ABOVE ROOF. INSTALLATION SHALL CONFORM TO THE MANUFACTURER'S INSTRUCTIONS, INSTRUCTIONS SHALL BE AVAILABLE AT THE JOBSITE. 10. ALL DUCTWORK MUST BE COORDINATED WITH CEILING HEIGHT, LIGHTING LAYOUT AND ROOF STRUCTURE ABOVE. (TYPICAL ALL SUPPLY RETURN, AND EXHAUST DUCT.) 11. NOT USED. 12. REFER TO ELECTRICAL DRAWINGS FOR EF-3 REMOTE VARIABLE SPEED CONTROL LOCATIONS. 13. PROVIDE RADIUS ELBOW IN EVERY CHANGE OF DIRECTION IN GREASE EXHAUST DUCTS. 14. PROVIDE DUCT MOUNTED TEMPERATURE/HUMIDITY SENSORS PER PLANS. VtIsO32- REVIEWED FOR CODE COMPLIANCE APPROVED Stantec Architecture Inc. 1383 North McDowell Blvd., Suite 250 Petaluma CA 94954 .stantec.com ) a o o. z 0 3 . U 2 O c Nh '5/3 o - -0t Q 0 0 Qy .0 D O 0 • o 0 - 0 he ° U O c o U-°O L t Engineers, Inc. 760 Creel Drive Wood Dale, IL 60191 Tel. 630/595-8800 Fax 630/595-8818 www.WCWengineers.com Q CO• OD CL m� L CD W N < W R (• 7)' U O M F-- 0, NO REVISION ISSUED FOR PERMIT 10/08/2015 & BID `& a-3 % r 61 ia AL '0/08/ 2015 Date Cd EXPIRES Expiration Date 10/05/2017 1 0 co W ct 0 1..1.E 0 LL 0 W (1) O CITY OF TUK WILA 00 O PECEi\/ED OCT 0 9 2015 PERMIT CENTER O DRAWN BY: CW CHECKED BY: SK PROJECT NUMBER 2007855013 SHEET NUMBER NOV 16 2015 City of Tui,f ila BUILDING DIVISION MIOI Mechanical Floor Plan DATE OF THIS PRINTING - Oct 08, 2015 Oct 08, 2015 - PACKAGED ROOF -TOP UNIT COOLING CAP. MBH @ 95 DEG. F. AMB. * HEATING CAPACITY FAN SECTION ELECTRICAL MAX HEIGHT (IN) DESIG. EDB EWB INPUT OUTPUT EFF OA ESP WEIGHT INCLUDING NOMINAL TRANE MODEL NO. TOTAL SENS. DEG.F DEG.F IEER* MBH MBH % CFM CFM IN. WG. HP VOLT PH MCA MOP (LBS) CURB TONS RTU-1 92.0 68.6 80.0 67.0 14.5 150 120 80 3000 750 1 3.75 208 3 41.9 50 1293 61 7.5 YHC092 RTU-2 92.0 68.6 80.0 67.0 14.5 150 120 80 3000 750 1 3.75 208 3 41.9 50 1293 61 7.5 YHC092 RTU-3 116.8 94.1 80.0 67.0 14.7 150 120 80 4000 200 1 3.75 208 3 46.1 60 1526 65 10.0 YHC120 NOTES: 1. *AT COOLING STANDARD: 80 DEGREES F. DB, 67 DEGREES F WB INDOOR COIL ENTERING TEMPERATURE AND 95 DEGREES OUTDOOR COIL ENTERING CONDITION. 2. PROVIDE UNITS WITH 14" ROOF CURBS. 3. FOR ALL UNITS PROVIDE WI FACTORY INSTALLED DISCONNECT (FACTORY WIRED), FACTORY MOUNTED 110 VOLT WPIGFI CONVENIENCE OUTLET (FIELD WIRED UNDER ELECTRICAL SECTION), BOTTOM POWER ENTRY FOR ELECTRICAL. 4. PROVIDE WITH LOW AMBIENT CONTROL, ENTHALPY ECONOMIZER WITH BAROMETRIC RELIEF, CONDENSER COIL HAIL GUARD, FACTORY INSTALLED SUPPLY AIR SMOKE DETECTOR. 5. SMOKE DETECTORS SHALL BE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND ALL ROOF -TOP UNITS SHALL SHUT DOWN UPON ACTIVATION OF THE FIRE ALARM SYSTEM. 6. PROVIDE UNITS WITH 2" FILTERS, HINGED ACCESS DOORS. 7. FURNISH PROGRAMMABLE ENTOUCH CONTROLS THERMOSTAT, AND REMOTE COMBINATION TEMPERATURE AND HUMIDITY SENSOR FOR ALL UNITS. PLEASE NOTE: 8. 2 YEAR LABOR WARRNTY, 5 YEAR PARTS ONLY WARRANTY, 10 YEAR COMPRESSOR AND HEAT EXCHANGER PARTS ONLY WARRANTY. INSTALLING CONTRACTOR SHALL PROVIDE A 1 YEAR INSTALLATION WARRANTY ON EQUIPMENT. 9. PROVIDE DE -HUMIDIFICATION - HOT GAS RE -HEAT FOR RTU-1 & RTU-2 ONLY (FRONT OF HOUSE). HVAC UNITS PROVIDED BY OWNER. CORNER BAKERY CAFE HAS AN 10. APPROVAL REQUIRED BY CBC FOR ANY DEVIATIONS. EXCLUSIVE NATIONAL ACCOUNT AGREEMENT WITH TRANE. PLEASE CONTACT YOUR LOCAL TRANE SALES OFFICE FOR PRICING, OR CONTACT TRANE NATIONAL ACCOUNT MANAGER ETHAN KINSEY @ 972-406-6081, ETHAN.KINSEY@TRANE.COM. FAN SCHEDULE S.P. VOLTAGE CURB O.D. FAN WT. ACCESSORIES TAG SERVICE CFM (INCHES) HP AMPS RPM MODEL (18 GAUGE) (LBS) & NOTES EF-1 ITEM H-1 & H-2 HOOD EXHAUST 2,547 1.25" 1.5 20816013 4.7AMPS 1274 BDU18 COMBO CURB W/ MUA-1 21"Wx 106"Lx20"H HINGED -LOUVERED 775 RC, DS, EA, UL 762 MUA-1 ITEM H-1 & H-3 OVEN HOOD SUPPLY 1,297 .75" 1.5 208160/3 4.7 AMPS 1046 NRTP.A-GM-A1-D250 COMBO CURB WI EF-1 21"W x 106"L x 20 H HINGED -LOUVERED 775 RC, WP, IEX, WD EF-2 PUBLIC TOILET EXHAUST 350 .5" 0.25 11516011 2.0 AMPS 1370 DR3OHFA 17-1/2"SQ x 14"H 48 RC, BDD, DS, SCR CONTROL EF-3 KITCHEN AIR TRANSFER FAN 1,050 .25" 3/4 11516011 9.8 AMPS 1677 COOK 135SQN17DEC - 154 IH, R-SCR, ISO ACCESSORIES DS = NON -FUSED SERVICE DISCONNECT IEX = INTAKE EXTENSION SI = SIDE INLET IH = INSULATED HOUSING EC = EPDXY COATING MEP = MASTER ELECTRICAL PANEL SIT = SIDE INLET TRANSITION ISO = VIBRATION ISOLATOR (NEOPRENE) FILT = PERMANENT FILTER RC = ROOF CURB WD = WEATHER HOOD TS =THERMOSTAT FL = FLANGE SCR = SPEED CONTROL PE = PREMIUM EFFICIENCY MOTOR R-SCR =REMOTE SPEED CONTROL SEE PLANS GB = GREASE BOX SD = SIDE DISCHARGE WP =120V WIRING PKG. TO KITCHEN HOOD AND FAN DETAILS SHEETS M302, M303, M304. PRESSURE ACROSS EXPO WINDOW. BDD = BACKDRAFT DAMPER BS = BIRDSCREEN DDP = DOWN DISCHARGE PLENUM EA = EXHAUST ADAPTER ALL EXHAUST FANS ARE OWNER SUPPLIED - REFER BALANCE AND SET EF-3 AT START-UP TO NEUTRALIZE GRILLES - REGISTERS - DIFFUSERS DESIG. DUTY MOUNTING LOCATION MATERIAL FINISH EQUAL TO TITUS MODEL # A SUPPLY CEILING ALUMINUM FACTORY FINISHED WHITE TMS-M, 24X24 MODULE B SUPPLY CEILING ALUMINUM FACTORY FINISHED WHITE PAS -AA, 12X12, 3-WAY DISCHARGE PATTERN C SUPPLY CEILING ALUMINUM FACTORY FINISHED WHITE PAS AA X 24X24, 4-WAY DISCHARGE PATTERN D1 SUPPLY CEILING ALUMINUM FACTORY FINISHED WHITE PAS -AA X24X24, NO PATTERN CONTROL DEVICE D2 SUPPLY CEILING ALUMINUM FACTORY FINISHED WHITE PAS AA X 24X24, NO PATTERN CONTROL DEVICE D3 SUPPLY CEILING ALUMINUM FACTORY FINISHED WHITE PAS AA X 16X16, NO PATTERN CONTROL DEVICE R1 RETURN CEILING ALUMINUM FACTORY FINISHED WHITE PAR 24X24 MODULE, 22 X 22 NECK R2 RETURN CEILING ALUMINUM FACTORY FINISHED WHITE PAR 12X12 MODULE, 10 X 10 NECK R3 RETURN CEILING ALUMINUM FACTORY FINISHED WHITE 50F EGGCRATE 24X24 R4 RETURN CEILING ALUMINUM FACTORY FINISHED WHITE 350RL 12X8 E EXHAUST CEILING ALUMINUM FACTORY FINISHED WHITE 350RL 12X12, PROVIDE OPPOSED BLADE DAMPER F SUPPLY • CEILING ALUMINUM FACTORY FINISHED WHITE TDC-AA 24" X 24", 21" X 21" NECK NOTES 1. GRILLES AND DIFFUSERS SHALL BE COMPATIBLE WITH THE CEILING IN WHICH THEY ARE INSTALLED. 2. ALL SUPPLY DIFFUSERS AND RETURN AIR GRILLES FINISH SHALL BE FACTORY FINISHED WHITE. 3. PROVIDE SUPPLY DIFFUSERS WITH D-75 OBD 4, PROVIDE EXHAUST AIR GRILLES WITH AG-100 5. ALL DIFFUSERS IN CLOSE PROXIMITY TO KITCHEN HOODS SHALL BE 3-WAY DIFFUSERS WITH NO AIRFLOW DIRECTED TOWARDS HOODS, 750 O.A. L_ 750 350 E.A. EF-2 O.A. DINING 2,547 E.A. EF-1 SPEED CONTROLLER 0 CFM GAS -FIRED MAKE UP AIR UNIT DESIG. INPUT (BTUH) OUTPUT (BTUH) TEMP RISE (F) REQUIRED INPUT GAS PRESSURE GAS TYPE MUA-1 80,965 74,488 55 7" w.c. - 14" w.c. NATURAL REFER TO MUA DETAILS ON HOOD SHEETS. DUCT RUNOUT AND DIFFUSER NECK SIZE CFM DIA. 0-120 6" 121-240 8" 241-400 10" 401-650 12" ABOVE 650 14" MUA-1 O.A. KITCHEN HOOD-1 HOOD-2 200 O.A. CEILING PASS-THRU I WINDOW L FIRST FLOOR NOTES: 1. EF-3 TRANSFERS AIR FROM DINING AREA TO THE KITCHEN. IT HAS A VARIABLE SPEED MOTOR AND THE SPEED (AIRFLOW) IS USER CONTROLLED TO MAINTAIN THE APPROPRIATE AIR VELOCITY ACROSS THE EXPO WINDOW. 2. ALL VALUES SHOWN FOR AIRFLOWS ARE IN CFM. AIR BALANCE TABULATION KITCHEN UNIT NO. SUPPLY CFM OA CFM EXHAUST CFM RTU-3 EF-1 MUA-1 4,000 200 1,297 2,547 SUB -TOTAL 4,000 DINNING 1,497 2,547 UNIT NO. SUPPLY CFM O.A. CFM EXHAUST CFM RTU-1 RTU-2 EF-2 EF-3 (TRANSFER) 3,000 3,000 750 750 350 1,050 SUB -TOTAL 6,000 AIR BALANCE SUMMARY 1,500 1,400 AREA SUPPLY CFM O.A. CFM EXHAUST CFM KITCHEN DINNING 4,000 6,000 1,497 1,500 2,547 350 TOTAL 10,000 2,997 2,897 -1,050 100 POSITIVE 100 POSITIVE NOTES: EF-3 IS A TRANSFER AIR FAN AND DOES NOT AFFECT THE OVERALL BUILDING AIR BALANCE. SYSTEM SUMMARY HVAC DESIGN PARAMETERS CITY SUMMER DESIGN OUTDOOR SUMMER DESIGN INDOOR WINTER DESIGN OUTDOOR WINTER DESIGN INDOOR PORTLAND, OR 86°F / 66°F 75°F / 50%aRH (DINING) SO°F 160%RH (KITCHEN) 27F 75°F BUILDING U-VALUE GLASS U-VALUE SYSTEM VENTILATION RATE FILTRATION CRITERIA AS PER ASHRAE 52-76 RTU-1/2/3 PER TABLE ABOVE 1"-30% EFF ROOF = 0.048 WALL =0.064 GLASS = 0.4 SC=0.55 SYSTEM OCCUPANCY SYSTEM # OF PEOPLE OUTSIDE AIR (CFM) TYPE OF OCCUPANCY DESIGN NOTES: RTU-1 51 750 DINING RTU-2 63 750 DINING RTU-3 7 200 KITCHEN HVAC LOAD SUMMARY SENS. COOLING (BTUH) LATENT COOLING (BTUH) TOTAL COOLING (BTUH) HEATING (BTUH) WALL 722 - 722 4315 GLASS 42551 - 42551 15243 ROOF 4504 - 4504 4532 FLOOR - - - 2520 PEOPLE 24685 31883 56568 - VENTILATION 83425 61078 144502 223986 LIGHTING 6712 - 6712 - EQUIP. & MISC. 8524 - 8524 - TOTAL 171123 92961 264084 250596 ENTOUCH ENERGY MANAGEMENT (OPTIONAL) ENTOUCH GM8 ENTOUCH GM4 ELECTRICAL POWER DISTRIBUTION PANEL 2 WIRE (TYPICAL) WIRELESS COMM. ENTOUCH ONE MASTER CONTROLLER RTU 1 2 WIRE (TYPICAL) H ROOM TEMPERATURE AND HUMIDITY SENSOR r 1 RTU-1 LHOT GAS REHEAT COIL 7 WIRE (TYPICAL) SLAVE CONTROLLER RTU 2 H ROOM TEMPERATURE AND HUMIDITY SENSOR r RTU-2 HOT GAS L J REHEAT COIL SLAVE CONTROLLER RTU 3 ROOM TEMPERATURE SENSOR r l RTU-3 II II LJ NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR POWER MONITORING EQUIPMENT. 2. MECHANICAL CONTRACTOR TO INSTALL ENERGY TOUCH MANAGEMENT SYSTEM. 3. REFER TO DRAWING M101 FOR CONTROLLER LOCATIONS. REVIEWED FOR CODE COMPLIANCE APPROVED a Stantec Architecture Inc. 1383 North McDowell Blvd., Suite 250 Petaluma CA 94954 .stantec.com a) >- o -CD 9 -0 o2, Z L 0 3 C o C 0 E o o -o 0't 0 a a)�' ,a D . 0 0 '0 '0' 0 0 0 0 H U o c `c .3 U o 0 a) 0 0 0 0 C 0 U 'O 0 o_ 0. as 0 C o o U 00 a0 o�, 0> a) =a .p 0 0 m� C 0 0 2 a-- ac 0 c*) rnr o a0 o ° u0. 0) C T 0 0_0 U a) o Engineers. Inc. 760 Creel Drive Wood Dale, IL 60191 Tel. 630/595-8800 Fax 630/595-8818 www.WCWengineers.com PROTOTYPE 5.2.13 NO REVISION ISSUED FOR PERMIT & BID 10/08/2015 Date 17, 'EXPIRES Expiration Date 10/05/2017 R .CE.4vtfl CITY OF TUKWILA OCT 0 9 2015 PERMIT CENTER 0 05 W a. 0 LL 0 W V J V J LO N 00 DRAWN BY: CW CHECKED BY: SK PROJECT NUMBER 2007855013 SHEET NUMBER o1 AIRFLOW DIAGRAM / SCALE: NTS NOV 16 2015 City o; Tukwila BUILDING G DIVISION 202 Mechanical Schedules DATE OF THIS PRINTING - Oct 08, 2015 SCB ATTACHED TO TOP OF JOIST WITH JAH E 0 0 w 0 0- 0- 111mi1, v,o„ 11� �I,.HIV Illill''�I 11111111 STRUCTURAL \._ STEEL BEAM SCBV - SEISMIC CABLE BRACE VISE REF. PAGE X3 MAXIMUM SCB/SSB LOADS TO STRUCTURE UP TO 1:1 BRACE ANGLE SCBV SIZE TENSION* Ibs (kN) SHEAR Ibs (kN) 1 2 3 690 (3.1) 1450 (6.5) 2230 (10.0) 690 (3.1) 1450 (6.5) 2230 (10.0) *FOR UP TO 1.5:1 OR 2:1 BRACE ANGLE, MULTIPLY BY 1.2 OR 1.3 RESPECTIVELY. MASON TYPE SSB SEISMIC BRACKET AIRFLOW The JAH is used to attach solid or cable braces to the top cord of bar joists. Attachment to the lower cord is not recommended. "E" TAPPED HOLE IN DUCTILE IRON CASTING. BOLT BY OTHERS. TYPE JAH DIMENSIONS inches (mm A SCB or SSB BOLT LENGTH IS ANGLE LEG LENGTH PLUS 1 1/2" (40mm) MINIMUM NEOPRENE FRICTION WASHERS Max. Load Ibs (kgs) Size SCB/SSB Size A B C D E SCB SSB JAH-0 SCB-0 3 (76) 3/4 (19) 1 7/8 (48) 1 3/4 (44) 3/8-16UNC 500 (227) - - JAH-1 SCB/SSB-1 3 (76) 3/4 (19) 1 7/8 (48) 2 1/4 (57) 1/2-13UNC 975 (442) 1500 (680) JAH-2 SCB/SSB-2 3 (76) 3/4 (19) 2 1/8 (54) 3 (76) 5/8-11 UNC 2050 (930) 3000 (1361) JAH-3 SCB/SSB-3 3 (76) 3/4 (19) 2 1/2 (64) 3 3/4 (95) 3/4-10UNC 3150 (1429) 5000 (2268) ADDITIONAL UPPER SUPPORT TO STIFFEN DUCT STEEL BRACE MAXIMUM 9'-6" JOIST ATTACHMENT HARDWARE SCALE: NTS SUPPORT STRUCTURE DUCT L 1IN. 1 MASON TYPE SSB SEISMIC BRACKET of ROD COUPLING MASON TYPE SRC OR UR SEISMIC ROD CLAMP IF REQUIRED. THREADED ROD ROD STIFFNER ANGLE OR STRUT IF REQUIRED. ROD COUPLING FOR LOWER ROD ATTACHMENT. NO. 10 SELF -TAPPING SHEET METAL SCREWS MAXIMUM 12 IN. O.C. TOP AND BOTTOM TRAPEZE SUPPORT 08 TRANSVERSE SEISMIC SOLID BRACE SCALE: NTS SUPPORT STRUCTURE MASON TYPE SSB SEISMIC BRACKET ADDITIONAL UPPER SUPPORT TO STIFFEN DUCT ASBH OPTIONAL ATTACHMENT AIRCRAFT CABEL MASON TYPE SCBH SEISMIC BRACKET DUC L ROD COUPLING MASON TYPE SRC OR UR SEISMIC ROD CLAMP IF REQUIRED. THREADED ROD ROD STIFFNER ANGLE OR STRUT IF REQUIRED. ROD COUPLING FOR LOWER ROD ATTACHMENT. NO. 10 SELF -TAPPING SHEET METAL SCREWS MAXIMUM 12 IN. O.C. TOP AND BOTTOM TRAPEZE SUPPORT TRANSVERSE SEISMIC CABLE BRACE DETAIL SCALE: NTS ISOMETRIC VIEW 45° BRANCH DUCT TAP SCALE: NTS AIRFLOW AIRFLOW TRANSITION DUCT MASON TYPE SSB SEISMIC BRACKET ADDITIONAL UPPER SUPPORT T STIFFEN DUCT @.__TYPICAL TEE CONNECTION AT RTU SCALE: NTS 90° FIVE SECTION ELBOW 90° BRANCH TAKE -OFF AIRCRAFT CABEL MASON TYPE SCBH SEISMIC BRACKET ROD COUPLING MASON TYPE SRC OR UR SEISMIC ROD CLAMP IF REQUIRED. THREADED ROD ROD STIFFNER ANGLE OR STRUT IF REQUIRED. ROD COUPLING FOR LOWER ROD ATTACHMENT. TRAPEZE SUPPORT NO. 10 SELF -TAPPING SHEET METAL SCREWS MAXIMUM 12 IN. 0.C. TOP AND BOTTOM LONGITUDINAL SEISMIC CABLE BRACE SCALE: NTS SEE SIZE ON DWG. RANSITION DUCT SPLITTER DAMPER 45° THREE SECTION ELBOW 45° BRANCH TAKE -OFF TYPICAL ROUND DUCT FITTINGS SCALE: NTS SPIN COLLAR FITTING, WITH MANUAL VOLUME DAMPER ROUND METAL DUCTWORK BRANCH b AIR DUCT DUCT STRAP FASTENER (TYP.) INSULATED FLEXIBLE DUCT, 60" MAXIMUM LENGTH —� TRANSITION FITTING FOR DIFFUSER/GRILLE IF REQUIRED METAL ELBOW MINIMUM STRAIGHT SECTION ENTRY INTO DIFFUSER SHALL BE EQUAL TO BRANCH SIZE SUSPENDED CEILING NOTE: PROVIDE RIGID COLLAR WHEN SPACE DOES NOT ALLOW FLEX TO BE USED. TYP. DIFFUSER OR GRILLE CONNECITON SCALE: NTS DIFFUSER/GRILLE, SEE DRAWING A TRANSFORMATION TURNING VANES 90° ELBOW TAKE -OFF USE ONLY IN AREAS WHERE SPACE IS LIMITED MASON TYPE SSB SEISMIC BRACKET ADDITIONAL UPPER SUPPORT T STIFFEN DUCT STEEL BRACE M 9'-6" MASON TYPE SSB SEISMIC BRACKET MUM 1 ROD COUPLING MASON TYPE SRC OR UR SEISMIC ROD CLAMP IF REQUIRED. THREADED ROD ROD STIFFNER ANGLE OR STRUT IF REQUIRED. OD COUPLING FOR LOWER ROD ATTACHMENT. PEZE SUPPORT O. 10 SELF -TAPPING SHEET METAL SCREWS MAXIMUM 12 IN. 0.C. TOP IN. AND BOTTOM 09 LONGITUDINAL SEISMIC SOLID BRACE SCALE: NTS SEISMIC RESTRAINT SCHEDULE PROVIDE SEISMIC SWAY BRACE ON ALL SUSPENDED PIPING PER 2012 IBC. SEISMIC SWAY BRACES SHALL CONSIST OF GALVANIZED STEEL AIRCRAFT CABLES OR STEEL ANGLES/CHANNELS. STEEL AIRCRAFT CABLES SHALL BE PRESTRETCED TO ESTABLISH A CERTIFIED MINIMUM MODULUS OF ELASTICITY. CABLE BRACES SHALL BE DESIGNED TO RESIST SEISMIC TENSION AND STEEL BRACES SHALL BE DESIGNED TO RESIST BOTH TENSION AND COMPRESSION LOADS WITH A MINIMUM SAFETY FACTOR OF 2. BRACE END CONNECTIONS SHALL BE STEEL ASSEMBLIES THAT SWIVEL TO THE FINAL INSTALLATION ANGLE. DO NOT MIX CABLE AND STEEL BRACES TO BRACE THE SAME SYSTEM. STEEL ANGLES, WHEN REQUIRED, SHALL BE CLAMPED TO THE THREADED HANGER RODS AT THE SEISMIC SWAY BRACE LOCATIONS UTILIZING A MINIMUM OF TWO DUCTILE IRON CLAMPS. THE BRACING SYSTEM SHALL HAVE AN ANCHORAGE PREAPPROVAL "R" NUMBER FROM A RECOGNIZED GOVERNMENT AGENCY SHOWING MAXIMUM RESTRAINT RATINGS VERIFYING ITS CAPABILITY TO RESIST SEISMIC FORCES. CABLE BRACE ASSEMBLIES SHALL BE TYPE SCB, STEEL BRACE ASSEMBLIES SHALL BE TYPE SSB, ROD CLAMPS SHALL BE TYPE SRC, PIPE CLEVIS BRACES SHALL BE TYPE CCB AND MULTIPLE ANCHOR LOAD DISTRIBUTION BRACKETS SHALL BE TYPE SLDB ALL AS MANUFACTURED BY MASON INDUSTRIES, INC. OR EQUAL AS APPROVED BY LOCAL AUTHORITIES. STRAP HANGERS HANGER STRAPS CONTINUOUS HANGER STRAP AROUND DUCT TRAPEZE HANGERS STRAP OR ANGLE SIZE BOLT(S) FOR LOAD ROUND RIGID 1"WIDE, 18 GA. SUPPORT STRAP W/ 5'-0" MAXIMUM SPACING UNLESS FOOT OF STRAP IS PLACED UNDER A BOTTOM REINFORCEMENT ALL THREAD ROD STRUCTURE ALL THREAD ROD 04 DUCT SUPPORT DETAILS SCALE: NTS B HREE TURNING VANES NO THROAT RADIUS TURNING VANES EXPANSION SUPPLY OR RETURN WYE (RECTANGULAR DUCT) 90° ELBOW 45° ELBOW SIMILAR DUCTWORK DETAILS SCALE: NTS CONTRACTION ROUND RIGID DUCT TURNING VANE 3/4 D RETURN AIR RANCH FITTING FULL RADIUS 2/3D SHORT RADIUS REVIEWED FOR CODE COMPLIANCE FULL RADIUS ELBOW PO TAKE -OFF NDV 16 2015 City of Tukwila RUIL,DIN G DIVISION ramia u Fug Stantec Architecture Inc. 1383 North McDowell Blvd., Suite 250 Petaluma CA 94954 .stantec.com N o 0 Ha 05 z L 0 . C o E 'o •0 0-tc o a 00 ay Et °) 0 •0 O o 0 U 0 o U-• `0 oPc- 0 c > c 0 0) C Engineers, Inc. 760 Creel Drive Wood Dale, IL 60191 Tel. 630/595-8800 Fax 630/595-8818 www.WCWengineers.com IW •c0 _1 3co co 0'6 La. LIJ�Q z CV U65 • Q U M - Cr) 0 0) PROTOTYPE 5.2.13 NO REVISION ISSUED FOR PERMIT 10/08/2015 & BID Expiration Date RECEIVED CITY OF TUKWILA OCT 0 9 2015 PERMIT CENTER 1 0/08/201 5 DRAWN BY: CW CHECKED BY: SK PROJECT NUMBER 2007855013 SHEET NUMBER M301 Mechanical Details DATE OF THIS PRINTING - Oct 08, 2015 Oct 08, 2015 - 11:44am HOOD NO, TAG MODEL LENGTH COOKING TEMP. EXAUST HLENG.PLENUM)CFM TOTAL SUPPLY FM HOOD TION CONSTRUCTION HOOD CONFIG. EXH.CFM RISERS END TO END ROW WIDTH S.P. 1 401 4824 GSN-2-P-F 9' 3.00' 450 Deg. 1572 10" 15" 1572 -0.348" 944 430 SS Where Exposed ALONE ALONE 2 302 6030 GSN-2-P-F 6' 6.00" 450 Deg. 975 10" 9" 975 -0.197" 585 304 SS Where Exposed ALONE ALONE TEMPERATURE SENSOR F------ REMOTE MANUAL PULL STATION ROOM TEMPERATURE SENSOR- FIELD WIRE TO ECP WITH WIRE PROVIDED IN ECP. FOR INFORMATION CONTACT J.D. HIGGINS COMPANY, INC. ARLINGTON, TEXAS 800-772-5452 CONTROL PANEL HMI INTERFACE TYPICAL CONTROL CENTER INSTALLATION AUST FAN INFORMATION - Job#2365426 ‘,// 1 48" HOOD NO. TAG FILTER(S) LIGHT(S) UTILITY CABINET(S) FIRE SYSTEM PIPING HOOD HANGING WGHT TYPE QTY. HEIGHT LENGTH EFFICIENCY @ 9 MICRONS CITY. TYPE WIRE GUARD LOCATION FIRE SYSTEM ELECTRICAL SWITCHES TYPE SIZE MODEL# QUANTITY 1 401 SS Baffle with Handles 6 16" 16" 30% 3 L55 Series E26 NO YES 459 LBS 2 302 SS Baffle with Handles 4 20" 16' 30% 2 L55 Series E26 NO Right Ansul R102 3.0 SC-311110FP 1 Light 1 Fan YES 530 LBS PERFORATED SUPPLY PLENUM(S HOOD NO. TAG POS. LENGTH WIDTH HEIGHT TYPE RISER(S) WIDTH LENG. DIA. CFM S.P. 1 401 Front 114" 9" 6" MUA 6" 28" 314 0.082" MUA 6" 28" 314 0.082" MUA 6" 28" 314 0.082" 2 302 Front 90" 9" 6" MUA 6" 28" 292 0.072" MUA 6" 28" 292 0.072" HOOD NO. TAG OPTION 1 401 FIELD WRAPPER 12.00" High Front, Left, Right LEFT END STANDOFF (FINISHED) 3" Wide 48" Long RIGHT QUARTER END PANEL 23" Top Width, 0" Bottom Width, 23" High 430 SS BALANCE DAMPERS 2 302 FIELD WRAPPER 2.00" High Front, Left, Right BALANCE DAMPERS A ROOM TEMPERATURE SENSOR ( WALL STAT) IS SHIPPED LOOSE INSIDE THE ELECTRICAL CONTROL PANEL. THIS SHOULD BE INSTALLED IN A SAFE PART OFTHE KITCHEN AREA THAT WILL BE UNAFFECTED BY EXTERNAL HEAT SOURCES. IT SHOULD BE INDICATIVE OF THE AVERAGE KITCHEN TEMPERATUREAWAY FROM THE COOKING APPLIANCES. 28" THERMAL SENSOR WIRED TO ECP U.L. Listed L55 Series E26 Canopy Light Fixture - High Temp Assembly 0 28 28" 9" 19 1/4" 55 1/2" 1/2'-F-- -L6" 1/2" tt 37 3/4" 9' 3.00"NomJ9' 3.00"OD 9.-6.00" Overall Length 37 3/4" 551/2" PLAN VIEW - Hood #1 (401) 9' 3.00" LONG 4824GSN-2-P-F FAN UNIT NO. TAG FAN UNIT MODEL # CFM ESP. RPM H.P. B.H.P. 0 VOLT FLA WEIGHT (LBS.) SONES 1 EF-1 GM16-HPFA 2547 1.250 1274 1.500 0.9910 3 208 5.0 147 12.1 2 EF-2 GMDR12H 350 0.500 1287 0.180 0.0940 1 115 1.9 37 7.1 3 EF-3 COOK 135SQNDEC 1050 0.250 929 0.750 0.1404 1 115 13.8 159 5.6 GAS FIRED MAKE-UP AIR UNIT(S FAN UNIT NO. TAG ACTUAL AIR DENSITY? INPUT BTUs OUTPUT BTUs TEMP. RISE REQUIRED INPUT GAS PRESSURE GAS TYPE 3 MUA-1 NO 83612 76923 55 deg F 7 in. w.c. -14 in. w.c. Natural FAN OPTIONS FAN UNIT NO. TAG OPTION (Qty. - Descr.) 1 EF-1 1 - Grease Box 2 EF-2 1 - 1 12-BDD Damper 3 MUA-1 1 - AC Interlock Relay - 24VAC Coil 1 - Motorized Backdraft Damper for Al-D Housing 1 - Low Fire Start 1 - Inlet Pressure Gauge, 0-35" 1 - Manifold Pressure Gauge, -5 to 15" we ESS FAN UNIT NO. TAG EXHAUST SUPPLY GREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT 1 EF-1 YES 2 EF-2 YES 3 MUA-1 YES NO. FAN WEIGHT ITEM SIZE 1 57 LBS Sieismic Curb 26.500"W x 26.500"L x 20.000"H Vented Hinged 2 44 LBS Sieismic Curb 17.500"W x 17.500"L x 14.000"H 3 63 LBS Sieismic Curb 21.000"W x 71.000"L x 20.000"H Insulated Seismic Rail 6.000' W x 21.000"L x 20.000"H Seismic Rail 4.000"W x 4.000"L x 36.000"H Direct Fired (DF) Pref1 Plate Assembly Dim. Fired Profile Plate Specifications: Desaiotion: Dim. fired burners shall have patented (US Patent No.: USS629523B2). sbHadjusting profile plat.designed to ensure proper air velocity are pressure drop across the burner. Profile Mates shall allow humors to achieve clean combustion by limiting bygrducl levels to a maximum of 5ppm of carbon monalde (CO), and 0.5ppm of nitrogen diadde (NO2). Apoliration: Spring -loaded bumar profile plates are engineered 00 automatically react to the momentum of a (rash air stream, without the need for any motors our actuators to mechanically adjust mere. With this feature, all DF units are designed for demand cantlol vmtilatbn (DCV) requiranol5. Certifications: All profile plate assemblies shall be included In the DF units ETL fisting and comply well mNtlned safety standards ANSI 283.4 and CSA 3.7 (non -recirculating DF healers) and ANSI 283.18 (recirculating DF heelers). General Censhu.lom -Profile plates shall be formed tram G90 galvanized steel. -Profile plates shall vary in size per uniL -Profile plates shall be mgunted along the same plane as the discharge ofthe bumar. -Design shall Incorporate property 1019000, parmanenlly mdmled sprig tinges. Spring hinges shall be made from palled steel. LIFTING LUG MUA FAN INFORMATION - Job#2365426 3" 60" THERMAL SENSOR FIELD WIRE TO ECP WITH WIRE PROVIDED IN ECP. U.L. Listed L55 Series E26 Canopy Light Fixture - High Temp Assembly O 28" O 28 Utility Cab net 9" 6" 1/2" 6" 1/2" El 22 1/Y 39" 45" 39 6' 6.00"NomJ6 6.00"OD 7-6.00" Overall Length 12" - PLAN VIEW - Hood #2 (302) 6' 6.00" LONG 6030GSN-2-P-F FOR INFORMATION CONTACT J.D. HIGGINS COMPANY, INC. ARLINGTON, TEXAS 800-772-5452 FAN UNIT NO. TAG FAN UNIT MODEL # BLOWER HOUSING CFM ESP. RPM H.P. B.H.P. 0 VOLT FLA WEIGHT (LBS.) SONES BURNER EFFICIENCY(%) 3 MUA-1 GM-A1-D.250-G10 G10 A1-D.250 1295 0.750 1046 1.000 0.5110 3 208 3.4 584 17.1 92 FAN #1 GM16-HPFA - EXHAUST FAN (EF-1) • 39 3/8 33 3/4 n '- ( 4GREASE DRAIN 2 J 161/2 24 28 7 1/4" DUCTWORK BETWEEN - EXHAUST RISER ON HOOD AND FAN (BY OTHERS) BLOWER DISCHARGE 13 1/4" -1 111n" L- FLEX CONDU T FOR FIELD WIRING 22 5/8 FEATURES: - ROOF MOUNTED FANS -RESTAURANT MODEL - UL705 AND UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT OPERATION 300°F (149°C) - GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600°F (316"C) FORA PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. OPTIONS GREASE BOX FAN #2 GMDR12H - EXHAUST FAN (EF-2) 23 3/4 GREASE MASTER HOODS ARE BUILT IN COMPLIANCE WITH UL 710 AND NFPA 96 AND ARE RECOGNIZED BY ONE OR MORE OF THE FOLLOWING: ETL SANITATION LISTED ETL LISTED FILE# 3054804-001 161/4 N.. 7 10 5/8 13 19 BACKDRAFT DAMPER INSTALLATION AIR FLOW 13 BACKDRAFT DAMPER (ROOF OPENING) FAN #3 GM-A1-D.250-G10 - HEATER (MUA-1) 1. DIRECT GAS FIRED HEATED MAKE UP AIR UNIT WITH 10" BLOWER 2. INTAKE HOOD WITH EZ FILTERS 3. DOWN DISCHARGE - AIR FLOW RIGHT LEFT 4. COOLING INTERLOCK RELAY. 24VAC COIL 120V CONTACTS. LOCKS OUT BURNER CIRCUIT WHEN AC IS ENERGIZED. 5. MOTORIZED BACK DRAFT DAMPER 16" X 18" FOR SIZE 1 STANDARD & MODULAR DIRECT FIRED HEATERS W/EXTENDED SHAFT, STANDARD GALVANIZED CONSTRUCTION, 3/4" REAR FLANGE, LF120S ACTUATOR INCLUDED 6. LOW FIRE START. ALLOWS THE BURNER CIRCUIT TO ENERGIZE WHEN THE MODULATION CONTROL IS IN A LOW FIRE POSITION. 7. GAS PRESSURE GAUGE, 0-35", 2.5" DIAMETER, 1/4" THREAD SIZE 8. GAS PRESSURE GAUGE, -5 TO +15 INCHES WC., 2.5" DIAMETER, 1/4" THREAD SIZE O O O AIRFLOW 32 1/8" 42 1/8" 118 5/8" SUPPLY SIDE HEATER INFORMATION: WINTER TEMPERATURE = 20°F. TEMP. RISE =55°F. BTUs CALCULATED OFF STANDARD AIR DENSITY OUTPUT BTUs AT ALTITUDE OF 0.0 ft. = 74428 INPUT BTUs AT ALTITUDE OF 0.0 ft. = 80900 29 3/4" ) • AIRFLOW SERVICE DISCONNECT SWITCH BLOWER/MOTOR ACCESS DOOR 24" SERVICE "CLEARANCE REQ. r DIRECT FIRED MODULE 3/4" NPT 39 9/16" / p - 7 13/16" 16 1/4" FEATURES: - ROOF MOUNTED FANS - UL705 - SAFETY DISCONNECT - STANDARD BIRD SCREEN - SPEED CONTROL OPTIONS 1 12-BDD DAMPER 1383 North McDowell Blvd., Suite 250 Petaluma CA 94954 .stantec.com Engineers, Inc. 760 Creel Drive Wood Dale, IL 60191 Tel. 630/595-8800 Fax 630/595-8818 www.WCWengineers.com CO GIJKM P0 NO REVISION ISSUED FOR PERMIT 110/08/2015 & BID D=te EXPIRES Expiration Date 10/05/201� ,i' EC EiVED CITY OF TUKWILA OCT 0 9 2015 PERMIT CENTER 0 co W a. Ct 0 0 W v / 1 0/08/201 5 DRAWN BY: CW CHECKED BY: SK PROJECT NUMBER 2007855013 REVIEWED FOR CODE COMPLIANC APPROVED NV 16 2015 I SHEET NUMBER 302 FOR INFORMATION CONTACT J.D. HIGGINS COMPANY, INC. ARLINGTON, TEXAS 800-772-5452 71 City of € ukw is BUI..L.D,i_NG Hood Details DATE OF THIS PRINTING - Oct 08, 2015 2015 - 11:45am FIRE SYSTEM BOX NOTE: 1) WIRE TO BUILDING ALARM SYSTEM FROM ALARM ENUNCIATING SWITCH. ROWN = NORMALLY CLOSED CAP OFF NORMALLY OPEN WITH FIRE SYSTEM COCKED C & NC = CIRCUIT C & NO = OPEN WITH FIRE SYSTEM FIRED C&NC=OPEN C & NO = CIRCUIT ' EACH MICROSWITCH IS RATED FOR 15 AMPS, 1/3 HP 125 OR 250 VAC, WITH 1/2 AMP @ 125 VDC AND 1/4 AMP @ 250 VDC. PROVIDE POWER TO AUTOMEN ALL SYSTEMS MUST BE CONNECTED TO THE SAME POWER SOURCE. 115 VAC 60 HZ HOT ACTUATION LINE NEUTRAL Am - ELECTRIC AUTOMAN 1 ELECTRIC AUTOMAN 2 WIRING FOR TWO OR MORE FIRE SYSTEMS SIMULTANEOUSLY WITH ELECTRIC SOLENOID GAS VALVES NOT REQUIRED IF MECHANICAL GAS VALVE IS USED. STARTER PANEL WILL BE PROVIDED WITH A ROOM TEMPERATURE SENSOR AS SHOWN. THIS SENSOR IS SHIPPED INSIDE THE ECP CABINET AND SHOULD BE INSTALLED IN A LOCATION AWAY FROM ANY HEAT SOURCES IT SHOULD INDICATE THE AVERAGE KITCHEN TEMPERATURE AWAY FROM APPLIANCES, HEAT SOURCES AND DIFFUSERS. TEMPERATURE SENSOR WIRE TO CONTROL BOARD. SENSOR MOUNTED IN EXHAUST DUCT. FACTORY WIRED TEMPERATURE SENSOR. MOUNTED IN EXHAUST DUCT. REMOTE MANUAL PULL STATION ROOM TEMPERATURE SENSOR WIRE TO CONTROL BOARD. OPTIONAL ELECTRIC GAS VALVE WHEN ELECTRIC VALVE IS USED (INSTEAD OF MECHANICAL VALVE) i i [Kraal 208VAC Neutral HMI INTERFACE GIOUna Neutral 120VAC E SHUNT N COIL / CONTROL PANEL TYPIC y�z�zs®zzII<OIZ MIc~n<UQCe (1 III III I Iu I 1 - .47 otrM r -1 r L T `r f Groom J Hot Hot ST TERMINAL IS ENERGIZED IN FIRE CONDITION. ONLY ENERGIZED AT LCD. Neural J PANEL ON HOOD AFTER H01 FIRE SYSTEM IS RE -ARMED. "24 TYPICAL TWO HOOD CONTROL CENTER AND ANSUL INSTALLATION J 4 J J r I-Z L L J L L L 4 J L T1A T1 B BALANCE DAMPERS HANGING ANGLE 16' SS BAFFLE WITH HANDLES AND HOOK 3' INTERNAL STANDOFF IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. GREASE DRAIN WITH REMOVABLE CUP RIGHT QUARTER END PANEL KITCHEN TEMP SENSOR ROOM TEMP T2A T2B T2A T2B DUCT SENSOR UNK UNK DUCT SENSOR UNK UNK SPARE DRY CC SPARE CONTACTS USED WHEN FIRE SYSTEM DISCHARGES EQUIPMENT OR PROVIDE SIGNALS. (NOT FORBUI DING FIRE WHICH MUST BE WIRED DIRECTLY TO THE ANSUL ALARM IN SWITCH LOCATED IN ANSUL AUTOMAN) ECP INTERNAL VIEW W/ WRG. TERMINALS 2012 IMC 507.2.1.1 OPERATION. Type I Hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliance, by means of heat sensors or by means of other approved methods. 508.1_MAKEUP AIR. For mechanical makeup air systems, the exhaust and makeup air systems shall be electrically interlocked to insure that makeup air is provided whenever the exhaust system is in operation. Makeup air intake opening locations shall comply with Section 401.4. Type I Hood Special Inspections Type I hoods and ducts shall be inspected by approved inspection agencies that satisfy the requirements as to qualifications and reliability. Final inspection reports from such approved agencies of the Type I hood and duct shall be accepted by the code official after the special inspections of hood and duct have been completed. (2012 IMC 107.2.4 & IMC 506.3.2.5) FANS BLACK HOODI WHITE TO GREEN HOOD WIRE TO J-BOX ON TOP OF HOODS MS( 4:N0 gg _,C-0%02.NC CMS-2 4:NO �2p-N� FP MICROSW IF MORE THAN ONE FIRE SYSTEM, WIRE IN SERIES AS SHOWN OPTIONAL FOR OUTS FOR �IN1E+n`iFATIgN CONTACT SIGNAL S1�ID iritGGI S COMPANY, INC. IDE SOURCE TO ACATKU ACy@L)Sj.FPN TEXAS f/iifF'C��L8n0J00--71772-5452 L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE) 48' 23" 23" 18' 48.0' MAX EQUIPMENT BY OTHERS SECTION VIEW - MODEL 4824GSN-2-P-F HOOD-#1 (401) FIELD WRAPPER 12.00" HIGH (SEE HOOD OPTIONS TABLE) ATTACHING PLATES SUPPLY RISER WITH VOLUME DAMPER 23.5% OPEN STAINLESS STEEL PERFORATED PANEL 24" NOM. 80" AFF REFERENCE "`v NO. V - TAG V - ..`V -V- PACKAGE # --V LOCATION SWITCHES OPTION FANS CONTROLLED LOCATION QUANTITY FAN TAG TYPE 0 H.P. VOLT FLA 1 ECP-1 SC-311110FP Utility Cabinet Right Utility Cabinet Right 1 Light 1 Fan Smart Controls Thermostatic Control EF-1 Exhaust 3 1.500 208 5.0 Hood # 2 MUA-1 Supply 3 1.000 208 3.4 JOB NO 2365426 MODEL NUMBER SC-311110FP IT SCHWAnc NYE INSTALL DESCRIPTION OF OPERATION: 3 Plea.rtEanm Fan. I SawaFnBrat,nrn.Lam wan Fn.F./0Or. To.rn.u.oAr ct50W. Bxmtwryw.wnProw owes b. P. JOB NAME cec Soulmm�lr 10.2015 ECP 41-1 BREAKER PANEL TO CONTROL PANEL Responsibility: Ele*Dician BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED BRENER PANEL CONTROL PANEL 10 11 18 IB BREAKER 1PH 120V 15A BREAKER3PH 208V MF . 10.8A M0CP: 15A CONTROL POWER. DO NOT WIRE TO SHUNT TRIP BREAKER PsTH000 LIGHT BREARSHARED WI CONTROL BREAKER POWER STMT. EF-1 &MUA-1 CONTROL PANEL TO FANS Responsibility: Electrician CONTROL PANEL Lood WIMB ST-1 WIREDIRECT TO STARTER W wwng ST-2 WIRE DIRECT TO STARTER MU - FAN: 01 WSW- - aru,eaz •.n RE TO FACTORY PROVIDEDCONDIIIT CROP CONTROL PANEL TO ACCESSORY ITEMS Responsibility: Electrician CONTROL PANEL CONTROL PANG TO N FIRE bra I EM - MICROSWITCX 'I CtTOCOMMON n) WIRE Mt TO NORMALLY CLOSED R) Cl MARI SHOULD HAVE 22 CONTHUIIY WHEN ARMED. CONTROL PANG TO SWITCHES CONTROL PANS. TO 14000 LIGHTS 1400 W MAX ALL 5 WITO€S FACTORY WISED arras s17its s:eslts CATS CONNECTION NOOO MITTS BL ACK GEEN PARE TO-80XONTOP OFHOOD CONTROL PANG - - - TO WI TSY=0YNOL Or�i .. - ROOM TE- M- P KITCHEN TEMP SENSOR MOUNTED IN ROOM AWAY SENSOR FROM HEAT SOURCES SEE LWdJ0J. CONTROL PANEL TO DUCT SENSOR Mate M41 FACTORY WIRED TEMPERATURE S1MR413 MOUNTED IN EXHAUST DUCT CONTROL PANG - Te IMRE TSMOUNTOLS1E/028. I+OWt DUCT SENSOR SENSORMOUMFDwENMUSTOUCTRISER I N000021 RISER 6ON0ROL PANEL SIGNAL FOR EXTERNAL SHUNT TRIP .].ante *IV* THE FOLLOWING CONNECTIONS MAY OR MAY NOT BE REQUIRED BASED ON JOBSRE SPECIFICATIONS ..._110T TO SHUNT COIL NEUTRAL FROM FROM SHUNT COIL ST TERMINAL IS ENERGOFD IN FIRE CONDITION CANTADLP.5a - - COMMON SPANS FIRE TAC.FORMALLY OPEN - SYSTEMDRY sm,ssM 00NISCSIIIOE TTODIIOSAABLEE CONTACT EQUIPMENT(RPM:W 2SIGNALS (NOT FOR BENDING FIRE ALARM WHICH MUSTST BEBALARM WIPED DIRECTLY TO THE ANSUL ALARM MINTING SWITCH LOCATED INANSUL WOMAN) CONTROL PANEL TO EXTERNAL SWITCH .la[. .3h7P BUS SWITCH _-_-- SIGNALSWTCH THROUGH TO.IS WILL ACTIVATE ZONE FANS AND UGHrS Exhaust Fan Wiring JOB 2365426-CSC SaRACenrer 1 DRAWING NUMBER 9012365426-1 SHIP DATE 10/6/2015 MODEL GM16-NPFA BK 2 4- „au� 401.R 10 11 12 13 15 18 17 18 10 20 e -0T- GR Instancd0obro 1&b0 LIT-01 CO3nppnen1 .en1nmt.n wun5w( Fm*OM5 1 ML m SW-01 Main dtrpv.0 WW1 RI MOTOR INFO EIDWART 1311P-208V-SPS.OFLA ELE INFORMATION MOTOWLI MOTORICTRL MOP. t5A NOTES DEN0105INTERNAL 0G DENOTES INIENNL w1RING BALANCE DAMPERS HANGING ANGLE 20" SS BAFFLE WITH HANDLES AND HOOK 3" INTERNAL STANDOFF IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. GREASE DRAIN WITH REMOVABLE CUP 60" - 24' 2 3/4' L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE) 6" FIELD WRAPPER 2.00" HIGH (SEE HOOD OPTIONS TABLE) ATTACHING PLATES SUPPLY RISER WITH VOLUME DAMPER 23.5,0 OPEN STAINLESS STEEL PERFORATED PANEL 30" NOM. 48.0" MAX 84" AFF REFERENCE EQUIPMENT BY OTHERS 11 SECTION VIEW - MODEL 6030GSN-2-P-F HOOD - #2 (302) UNLESS 1 Jg A I B I C I D I E SPECIFIED OTHERWISE, ALL FACTORY AC WIRING I6AWG. ALL FACTORY DC WIRING 1B AWG. 120V z - , wH CONTROL INPUT • Y T I F I G PUT END OF LINE PLUG IN SWIFGNEG EMPTYRJ45 JACK. PN:EOL120A CAT5 CABLE. LENGTH AS REQUIRED. I MOTOR POWER 14 AWG 3PH .3fE 2ISV 1YJ1 15A 1K) • 145 0 H I I CIRCUIT 50.1 OL-1 + Tt co. 10 jl52 SW6 300 sr.z asCORD WA to 1r .48 i.aao HMII ��7•--{-'[E,Iq�[ �® ECPL101 WIL 2I 1 LI BK 120VH1=LINE, 2 • - [r1:i1 4, Y4 N1=NEUTRAL. I5A ;' m I ERE MCI 2 [t9® N1 pan BRF4MFR DO NOT ® CONNECT TO SHUNT TRIP e0 24V t)C J6 QQQL�Qe QL Q• ©©y��,y�y© Fy0 101(11 aK (T 508 BREAKER. SEE m INSTALLATION BK "'emu.SCHEMATIC FOR t)18A. ri Ci T Mil(r1 RED. - 1^ sows .1, OR A 4 4 p O PANEL LID 3 4 _ J7 120V II = 5z1 I K RIGHT I IV' 0 BK M00 i(t& N1 (q 1 5M BK fECCE0 n Tt rmT- BMW BK , � I - vu nA, 6 H1 A H1 1 Nt a AR CON N1 - 00<R01 DC« -eateD 7 8 _ 9 0 DRY CONTACTS (SHOWN DE -ENERGIZED) 14 AWG RA-1-1 QWpFFVrf(HI FIRE 14x18x8B00 Exhaust Fan Wiring JOB 2365426 - CSC 500Ihpenler DRAWING NUMBER 0042365425-2 SHIP DATE 10/62015 MODEL GMDR17.1.1 4 10 11 12 13 1a 15 18 I7 18 10 20 Inslalloq 00000. Sped Control 0062 MT-01 OD01 scm swat Camanent 6111014e10n DFan Motor o. Odd Diso nm Sped Contra u.H8Amned MOTOR INFO EXHAUST 0.18HP-115V-1P-1.0PLA MOro,ma.Iicc10 IiNr0RMATON MOTOR/CTRL MOP:15A NOTES DENOTES FIELD WRING DENOTES INTERNAL WIRING I/ Direct Fired Heater WUing JOB 2365426 - CSC SOIlhcerner DRAWING NUMBER DF2365426-3 SHIP DATE 1078C015 MODEL G14A1-O250010 (ATTENTION ELECTRIC W II DROP FOR DISCONNECT CONNECTION IS FACTORY SUPPLIED CONNECT POWER TO THE DROP 1 2 0_ SW-01 CB-01 BK to BK BK WH 4 10 12 13 14 15 18 17 1a 1B 20 BK BK ST-01 0101 Ltll 1 2Ti BK Ian K MT-02 (LF12651 BK�_2O1 YM OL-01 ST-01 gax OK 90A1 pr BK C_ TSL3 �8L WH RE-10-1 CCRrifM ®4) FOR fib 20 RC QT5-0NZC WH BR Par hweiled Donors WWI. B. Con Dapper DbMMO0 Trap. Control 21VACIN.ILVA Relay EIS. Rn Fwm R`t.rde - uwsso.N0. PR Dongov 8.0, mobs wERW MOE Pam Mph ... EE RE-n ACnMN2ROY 050t Snq,aA,Otm SVI.01 M. damned so. ewm 7*...0R.A...n TR°m MOS PoorEr 1 om FwnnOvm,0E4y oW1ryAY =1 v., LWn oTA... 57 town p8r1R KI �qq Itq PO Itx 5 M TOR IMF SUPPLY 1HP208J3P0 r6v°E"HTn1P3 ®4oasolo - OENDIc I ➢WIRING FACTORY WIRING SCHEMATIC CIRCUIT BOARDS ECPM03 Rev.1.35 HMI Rev.1.06 REL AC ND NC COL Cal Ca F1f[ LIId 24Y6C RELAY C7 NO F� NC c. COL COY f ftf COMPONENT LIST Ue`-L 2144.00*I0N Ccolawc Fame w344.4. Wmgc IC %11IMO o0i0 PHMPNTTEYL i. .TDB NAME CBC h/enter ow/ 0OTI IF SC-3111105P LKSCRANION OF n Tengr T onswaw MPcoonam Raw Ne m brwtnmv. Nn'dYs ptuwN BY YPE FACTPRY 10 /62015 NO ECP(]-2 Stantec Architecture Inc. 1383 North McDowell Blvd., Suite 250 Petaluma CA 94954 .stantec.com O U 0 O 0. �c �° c.0 Eo 5 t C G7 0 O in . 0) - O 0 2 L' O 0 s m 0 2 2 CC 0 0 -C C U) 0) L_ N 0 0 0) 0 11 o ; _c C O) 0. _0 8 tD I- o Engineers, inc. 760 Creel Drive Wood Dale, IL 60191 Tel. 630/595-8800 Fax 630/595-8818 www.WCWengineers.com PROTOTYPE 5.2.13 FOR INFORMATION CONTACT J.D. HIGGINS COMPANY, INC. ARLINGTON, TEXAS 800-772-5452 CInstallation WKring JOB 2365426- CSC San 10911. 1 DRAWING NUMBER RP2355426.3 SHIP DATE 10100015 MODEL GA1-At-D9w10 120 V 1 PH. 240 V 1 PH. GaMex moduli (inMnit) Disconnect FectOy wing i. BK (GCCustomer sopo.MnR Disconnect cenda tin Uni0 FaCtOry wiring K. GR saw. trtIng Power Connection See above detailsA REVIEWED FOR CODE COMPLIANCE NO REVISION ISSUED FOR PERMIT 10/08/2015 Date 44. 015 EXPIRES Expiration Date 10/05/2017 RECEIVED CITY' OF TUKWILA OCT 0 9 2015 PERMIT CENTER 0 10/08/2015 DRAWN BY: CW CHECKED BY: SK PROJECT NUMBER 2007855013 SHEET NUMBER. 303 WIRE COLOR BK- BLACK Wi• YELL. BR -BROWN GT- GRAY OR- MEM. PR -PURPLE WN WIRE COLOR E.-BLACK VW -YELLOW SL- BLUE GR -GREEN ER -BROWN EY- GRAY OR -MANSE FR PURPLE WI, WHITE 21 TGOS BL DENOTES INTERNAL WRING CONNECTOR OR • ORANGE BUILD NG DIVISION , BK• BUCK BL -BLUE BR• BROWN OR- ORANGE WERE COLOR GY -GRAY PK -FINK Hood Details DATE OF THIS PRINTING - Oct 08, 2015 Oct 08, 2015 - 11:45am 1 II JYOLGI FIRE SYSTEM NO. 11 11 IIv1 Tag ll lclt vl1 - vvvirwvvTcv TYPE SIZE FLOW POINTS INSTALLATION SYSTEM LOCATION ON HOOD 1 FP-1 Ansul R102 3.0/1.5 8 Fire Cabinet Right Right v FIRE SYSTEM NO. TAG TYPE SIZE SUPPLIED BY 1 FP-1 Mechanical 1.250 Distributor 24.00" E 0- Hood # 1 (401) U ❑ 24.00" O OJ CD E 1.00" 71" 80.00" 29 I 21.50C) 18.00" 21" 13.00" Root Top Curbs are built in the following way. • Metal is .060" Aluminized Sheet Metal • All seams are welded with MIG using ER70S-6 wire. • Top flange is 1.00" wide. • Bottom flange is 3.00" wide. • Widths and lengths vary by product installed. • Max curb pitch is 5" on 12" enter Bolts along Flange. Space Bolts egtudistant along flange. 1.500" SEISMIC EQUIPMENT CURB WELD PLATE AND CENTERED TRANSITION TO BASE OF FAN FOR INSTALL FROM ABOVE AND WELD CONNECTION BELOW ROOF. RECOMMENDED TOPCAP FOR GREASE DUCT 71" DIM "F" DIM "A" DIM "G" DIM "B" E 0 0 Hood # 2 (302) 0 0 ®, Supply Portion is insulated. 15° SQ. 6" FEATURES: - THREE REMOVABLE ACCESS DOORS -ALUMINUM WHEEL - GALVANIZED STEEL HOUSING - UL705 -DIRECT DRIVE MOTOR - INSULATED HOUSING - DISCONNECT SWITCH PRE -WIRED - MOTOR MOUNTED SPEED CONTROL - ELECTRONICALLY COMMUTATED MOTOR OPTIONS RC-75 VIBRATION ISOLATORS (SET OF 4), STANDARD FEATURES 1. FACTORY INSTALLED 2x6 WOOD NAILER 2. WELDED 18 GA. GALVANIZED STEEL SHELL AND BASE PLATE 3. 1 1/2" THICK, 3-LB RIGID CURB INSULATION 4. 1" CAP INSULATION 5.3/4" WELDING FLANGE 6.20 GA. COUNTERFLASHING CAP ADDED OPTIONS 1.6" OVERHANG 2.18" HEIGHT 3. 2° FLANGE NOTE: FURNISHED BY OWNER, INSTALLED BY MECHANICAL CONTRACTOR. REFRIGERATION PIPING PENETRATION ASSEMBLY VERIFY (2) REQUIRED 4" MIN MECHANICAL GAS VALVE -FLOW DIM "C" DIM "D" STRAINER 18 OD Inlet View NOTES - FIELD PIPE DROPS AS SHOWN SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - MAXIMUM 9 ELBOWS IN SUPPLY LINE. - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE. - IF APPLICABLE, PRE -PIPED CHARBROILER DROPS ARE SHIPPED LOOSE: - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS SPECIFICATIONS THE RESTAURANT FIRE SUPPRESSION SYSTEM SHALL BE THE PRE-ENGINEERED TYPE WITH A FIXED NOZZLE AGENT DISTRIBUTION NETWORK. IT SHALL BE LISTED WITH UNDERWRITERS LABORATORIES, INC. (UL) THE SYSTEM SHALL BE CAPABLE OF AUTOMATIC DETECTION AND ACTUATION WITH LOCAL OR REMOTE MANUAL ACTUATION. ACCESSORIES SHALL BE AVAILABLE FOR MECHANICAL OR ELECTRICAL GAS LINE SHUT-OFF APPLICATIONS. THE EXTINGUISHING AGENT SHALL BE A POTASSIUM CARBONATE, POTASSIUM ACETATE -BASED FORMULATION DESIGNED FOR FLAME KNOCKDOWN AND SECUREMENT OF GREASE RELATED FIRES. IT SHALL BE AVAILABLE IN PLASTIC CONTAINERS WITH INSTRUCTIONS FOR LIQUID AGENT HANDLING AND USAGE. THE REGULATED RELEASE MECHANISM SHALL BE COMPATIBLE WITH A FUSIBLE LINK DETECTION SYSTEM. THE FUSIBLE LINK SHALL BE SELECTED AND INSTALLED ACCORDING TO THE OPERATING TEMPERATURE IN THE VENTILATING SYSTEM. THE FUSIBLE LINK SHALL BE SUPPORTED BY A DETECTOR BRACKET/ LINKAGE ASSEMBLY. Job #: 2365426 Job Name: CBC Southcenter Drawn By: System Size: ANSUL-3.0/1.5 Total FP required: 10 Hood # 1 9' 3.00" Long x 48" Wide x 24" High Riser # 1 Size: 10" x 15" Hood # 2 6' 6.00" Long x 60" Wide x 30" High Riser # 1 Size: 10" x 9" PLENUM PROTECTION NOZZLE DUCT PROTECTION NOZZLE OPTIONAL PRE -WIRED ELECTRICAL TERMINAL BOX WITH TERMINAL STRIPS, 3-PHASE CONTACTORS AND OVERLOADS (IF APPLICABLE) FAN AND LIGHT CONTROL PANEL TYPICAL ANSUL R-102 SYSTEM LAYOUT FOR INFORMATION CONTACT J.D. HIGGINS COMPANY, INC. ARLINGTON, TEXAS 800-772-5452 of o 0 O l0 oL 0 0 _ i0 0 oI- O I 1 0 I----- 20-1/4 ----I 22-1/4 FAN #4 COOK 135SON17DEC - EXHAUST FAN (EF-3) 0 0 0 0 0 0 0 0 0 0 ? o Centered Along Flange J 1.500" Max Spacing From Curb Edge DIM'B' 18 OD DETECTOR REMOTE MANUAL PULL STATION REMOVABLE STAINLESS STEEL SERVICE DOOR AGENT TANK OEM RELEASE/ BRACKET ASSEMBLY 18 OD Discharge View FOR INFORMATION CONTACT J.D. HIGGINS COMPANY, INC. ARLINGTON, TEXAS 800-772-5452 viewed from discharge at 9:00. Curbs are built in the following way. • Metal is 16 GA. Galvanized Sheet Metal • Top flange is 1.00" wide. • Bottom flange is 3.00" wide. • Widths and lengths vary by product installed. • Max curb pitch is 5" on 12" SEISMIC ROOF CURB 22-15/16 Curb Dimensions 3" Nominal VENTED CURB EF-2 ONLY REVIEWED FOR CODE COMPLIANCE APPROVED NOV 16 2015 �r°t Fr! Cityof I ut ita LADING DIVISION FOR INFORMATION CONTACT J.D. HIGGINS COMPANY, INC. ARLINGTON, TEXAS 800-772-5452 0 0 0 0 0 0 0 C 0 1383 North McDowell Blvd., Suite 250 Petaluma CA 94954 .stantec.com 0 U D 0 2 o at a -0 m ce O L _8 . z o 0 0 U N O m O C 0 E o a 0 ) o a m :15.m 0 0 ay 2 m 0 .0 ._ o 0 .-o m o >c c c 0 ac o 2 h $.0 m .&) 2 =0 — m `o .0 m0 3 0 0 26 0 c c O Da) .0) . o 0 m 0 0 o Q' o � a 0 C 3 0.`0 U0`U -0 m m m m Engineers, 3" Nominal VENTED CURB EF-2 ONLY REVIEWED FOR CODE COMPLIANCE APPROVED NOV 16 2015 �r°t Fr! Cityof I ut ita LADING DIVISION FOR INFORMATION CONTACT J.D. HIGGINS COMPANY, INC. ARLINGTON, TEXAS 800-772-5452 0 0 0 0 0 0 0 C 0 1383 North McDowell Blvd., Suite 250 Petaluma CA 94954 .stantec.com 0 U D 0 2 o at a -0 m ce O L _8 . z o 0 0 U N O m O C 0 E o a 0 ) o a m :15.m 0 0 ay 2 m 0 .0 ._ o 0 .-o m o >c c c 0 ac o 2 h $.0 m .&) 2 =0 — m `o .0 m0 3 0 0 26 0 c c O Da) .0) . o 0 m 0 0 o Q' o � a 0 C 3 0.`0 U0`U -0 m m m m Engineers, inc. 760 Creel Drive Wood Dale, IL 60191 Tel. 630/595-8800 Fax 630/595-8818 www.WCWengineers.com ° CO 1111 mCO N 1t1 a1 <1C co fj- 4 Z c 111 CO Q O (a)_. *" ° ~O 1 CD = 0 OCO I.... VJ NO REVISION ISSUED FOR PERMIT & BID 10 08/2015 . . I e Si ` q i h' . A '' t1v :3 t.:3 1 r1s`j'r` ti ` i31'JAl.,t\ t /08/2015 Date (EXPIRES t 1 nmc/oni 7 I Expiration Date D CITY OF TUKWIL A OCT 0 9 2015 PERMIT CENTER 0 M� I 2 W CI- LL- W D (1) CD O CVRECEIVE 0 O x-- DRAWN BY: CW CHECKED BY: SK PROJECT NUMBER 2007855013 SHEET NUMBER 304 Hood Details DATE OF THIS PRINTING - Oct 08, 2015