Loading...
HomeMy WebLinkAboutPermit M15-0133 - PIZZA STUDIO - ROOFTOP AIR CONDITIONING UNIT, HOOD AND EXHAUST FANPIZZA STUDIO 17250 SOUTHCENTER PKWY 148 M15-0133 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 7888920020 Permit Number: M15-0133 17250 SOUTHCENTER PKWY 148 Issue Date: 11/18/2015 Permit Expires On: 5/16/2016 Project Name: PIZZA STUDIO Owner: Name: Address: Contact Person: Name: WIG PROPERTIES LLC-SS 4811 134TH PL SE , BELLEVUE, WA, 98006 JEREMY MOELLER Address: PO BOX 3205 , KIRKLAND, WA, 98083 Contractor: Name: C F M HEATING AND COOLING INC Address: PO BOX 3205 , KIRKLAND, WA, 98083 License No: CFMHEHC969CD Lender: Name: Address: III Phone: (425) 821-1293 Phone: (425) 821-1293 Expiration Date: 2/4/2016 DESCRIPTION OF WORK: INSTALL 1 NEW ROOFTOP A/C UNIT, RE -USE 1 EXISTING ROOFTOP A/C UINIT, INSTALL NEW TYPE 2 HOOD FOR PIZZA OVEN AND 1 NEW EXHAUST FAN. Valuation of Work: $18,000.00 Type of Work: NEW Fuel type: GAS Fees Collected: $428.80 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: :di, - Date: 1 t"' 1 9 ,s- I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: G! treaty M &ter - Date: /( /6 15 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: D "1 1 , Date Application Expires: -' l 1 (For office use on y) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: &K2 �2o - Site Address: 17 Z SO SU't'��C.etl 'r Pa(k(Azty Suite Number: I _(U 6 Floor: Tenant Name: Pt--2 5+08 0 New Tenant: Yes ❑ ..No PROPERTY OWNER I Name: tv i l'nnRorekes j-L 6 Address: 4.65a 'rl i71/ , pi 5E l City: �lI evve, State: LA)A Zip: 79(4, CONTACT PERSON — person receiving all project communication Name: yeft auj M oen l e, Address: f> 6,0 3205- City: Kir �UT1 co State: /, tl Zip:c Phone: z05. m, /213 Fax: i62 _ori Email: 3-c.rl?niecFm-AU cg, (DAA MECHANICAL CONTRACTOR INFORMATION Company Name: cFj,,t Recrtu,5and c00tit Address: r.o. 60x 320y City: Ai t, (,' � _ _ J State: tid/ Zip: 780 Phone: !f-jam-821 `/Z13 Fax: 82!'13q,3 Contr RegriNNo.amilie uo Exp Date: 02 ico Tukwila Business License No.: / Valuation of project (contractor's bid price): $ Describe the scope of work in detail: 181oco i- 1-(14A I I new I-CO.9 o ,AC oA:1' , re-u e I t(7D1� AG (n1 } 10/01011 flew Ate Z huoJ f x2o, wen , GVIG i Use: Residential: New ❑ Replacement ❑ Commercial: New ® Replacement ❑ Fuel Type: Electric ❑ Gas e,)(Z5 `I' i J1Jr. new e4 4- 4t1 Other: H:Wpplications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system I Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct i Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/I,000,000 btu 30-50 hp/l,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O R OR AILMORIZED AGENT: / Signature: i�� t;�l'/f/v� Date: /A-� !-- Print Name: ��� odlr2-- /2cl3 �'�t?�y M Day Telephone: i(J Mailing Address: 1204 130)13206 4/11.co I 49 980l City State Zip H;Applications\Forms-Applications 0n Line\2011 Applications\0lechanical Permit Application Revised 8.9-I1.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT f QUANTITY PAID PermitTRAK $65.00 M15-0133 Address: 17250 SOUTHCENTER PKWY 148 Apn: 7888920020 $65.00 MECHANICAL $65.00 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R7927 R000.345.830.00.00 1.00 $65.00 $65.00 Date Paid: Tuesday, March 15, 2016 Paid By: C F M HEATING AND COOLING INC Pay Method: CHECK 9583 Printed: Tuesday, March 15, 2016 2:08 PM 1 of 1 C! SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT I QUANTITY PermitTRAK I PAID $428.80 M15-0133 Address: 17250 SOUTHCENTER PKWY 148 Apn: 7888920020 $428.80 MECHANICAL $412.31 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $297.35 PLAN CHECK FEE R000.322.102.00.00 0.00 $82.46 TECHNOLOGY FEE $16.49 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6385 R000.322.900.04.00 0.00 $16.49 $428.80 Date Paid: Friday, October 09, 2015 Paid By: CFM HEATING AND COOLING Pay Method: CHECK 9301 Printed: Friday, October 09, 2015 3:18 PM 1 of 1 CRWSYSTEMS IN ECTION NO. INSPECTION RECORD /5--tr % 331 Retain a copy with permit PERMIT NO. pp CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projec�ts i 1-2., 7-.'} pc� 'Type of Inspfcttlion: / feC',&. / 4 7 Address: S� C� ej-�y�J. Dade Called: /. ag f /7 S ecial Instructions: Date Wante9 a.m. p.m. Requester: Phone No: pproved per applicable codes. E1 Corrections required prior to approval. COMMENTS: Aeir‘'V Inspector: ✓`` 6,�f/*4._ �J Datel REINSPECTION FEE REQUIRED. Prior to next inspection! fee must be paid at 6300 Southcenter Blvd., Suite 100. Calf to schedule reinspection. INSPECTION RECORD Retain a copy with permit [1:-111 PECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.,. #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projec . V I " ram 141..531/i Typ/s/2f ins ec ' n: ,vr2 r4n: J Address:d_J•0 £ /Lce/L ►' /�'y�"C Called:, `!!� (` 6 Special Instructions: Date anted: /f/ a.m p.m Requester: Phone No: �-Approved per applicable codes. Corrections required prior to approval. COMMENTS: VV lnspector:1—" r Date: / REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be / paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. J INSPECTION RECORD Retain a copy with. permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Mf5---0/33 Project: z-N, r'? t /q Type Inspec ,Qn: 7 Address: i �7SL� N X.«:�ifg- P Dat C�fled: 4LeVA /�'' a Special Instructions: "xfDate Wad: AP J3 p.m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection,'fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projectzi Z /Q Type of Inspecii,on: / J".f/F' Address: ir / / Date Calle49 (d Special Instructions: to Wanted: Requester: // Phone No: ,; ram=lac 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: REINSPECT ON FEE REQUIRED. Prior to next inspection, fee ust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSP ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Projert'27 OA 1e . Type of In iCe"k n: r/WC Address: ('7 -a uJ c at Called: h /enal"ver / Instructions: Date Wa : 1 J a.rn Requeesteer . J. ��r h Pone No: � 91S" 7 76/ I 1 Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: Inspector: Date:. //t 5/( REINSPECTION FEE REQUIRED. Prior to next inspection,' fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit rlt5-c)1_ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 5fr,r /C Yp T e of I ection: �v 1�ez iVali_ �1. / '' Address: . J t/cvrG^ D. I • W'4'f li Special Instructions: late Wanted p.m. Requester: Phone No: / 7 aApproved per applicable codes. COMMENTS: orrections required prior to approval. -54frrt, fez c_ Inspector: REINSPECTION FEE REQUIRED. Prior to next insction, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. TurboChef HCT-3029 Item #16 Stacking HhC 2020 Ovens , WARNING; DO NOT use this appliance without the legs installed on the bottom oven. it WARNING: Make sure all HhC 2020 ovens are unplugged before stacking. Lt WARNING: DO NOT stack ovens more than 3 high. Lt WARNING: DO NOT attempt to lift the oven with fewer than:2 people. 1. Remove the legs from the °vents) that are going to be stacked on top. 2. Cover the leg holes with the abrasive pads provided with kit HCT-3001. 3a. If the front panel on each oven contains side hinges, skip to step 4. 3b. if the front panel on the ovens that are going to be stacked on top contain bottom hinges (adjacent), ensure that a thumb screw is installed on each side to allow forfront panel removal. If the oven has security screws, replace them with the thumb screws provided with kit HCT-3001, Step 3b: Must be Thumb Screw .0 4. Stack the top oven on the bottom oven. If stacking three ovens, stack only the middle oven at this point. S Remove the 6 screws marked A Or 3 n the Illustration below, rj, Allan each bracket with the holes in the bottom oven and reinstall the screws marked A in the Illustration below. 7. Align each bracket with the holes in the top oven and reinstall the screws marked 8 in the illustration below. 8. If stacking three ovens, repeat steps 2-6 above to stack the top oven to the middle oven. 9. Ensure each stacked oven is secured to the oven beneath It via two stacking brackets — one on each side, Stacking HhC 3240 Ovens i-ollow all instructions in the Installation Manual (part number HFIC-6651), included with each oven, RECEiVED CITY OF TUKWILA OCT 0 9 2015 PERMIT CENTER REVIEWED FOR CODE CO;viPLiANCE APP;',i01/7; NOV 1 6 2015 LBUICity of Tukwila LDING DIVISION MI6DI Pizza Stu io-Southcenter-Tukwila, WA Catena Development Services DOC-1032Revision Ei August 2010 TurboChef HCT-3029 Item #16 Stacking i3 and i5 Ovens Reference the below illustrations for the proper stacking configuration, as well as dimensions, 1, Unplug each oven. 2. Set the oven stand (part number 15-9369) in place. AWARNING: Do not attempt to lift the oven with fewer than 2 people. LL, WARNING: Position at least one person at the front and back of the oven and always use the hand grips when lifting. & WARNING: Do not lift the oven by the door handle. 3. Lock the wheels of the oven cart (part number NGC-121 7-2). 4. Place the lower oven on the oven cart. 5. Place the top oven on the oven stand. 6 Unlock the wheels of the oven cart and position it beneath the stand, as shown in the below illustration. .z94 tnerq 3}-5.1911 411?-tl Ow-11C 0 0 t Vat (726 triM tr(362 rnmt Li1826M.1) iS Oven 43.'ial7 'rims 44t11,33 rnrn) 32.5' 026 rm.? ch,ancitt,i 4* 172b trM}- 304," Ma nun) 13::751137) i3 Oven 1 ..., 21.23'640 ,,,no e.4t.Vti 2.-pvra) Pizza tudilo-Southcenter-Tukwila, WA Catena Development SeNices DOC-I On/Revision Et August 2010 ft, col 2 5 ez AM OE ot E •YJ LC t Aia tlig,P1 174, • -11q-21 rj. uj i j c 0 SHEET 3 0 Gca [12.001 304,8 112 2032 i8 001 A -1 0 cr E7 0 0 (.0 CO SHEET 1 OF 1 a UnitedTechnelegies'`: SUBMITTAL Project Pizza Studio Date Wednesday, October 07, 2015 Contractor CFM Heating & Cooling HEATING & COOLINGG, INC REVIEWED FOR CODE COMPLIANCE APPROVED NOV 16 2015 City of Tukwila BUILDING DIVISION Ping RECEVED CITY OF TUKWILA OCT 0 9 2015 PERMIT CENTER MIti-D133 Project: Pizza Studio Prepared By: 4t Unit 10/07/201: 11:39AN EJI Packaged R` liftop Build er 1439ss 4t Unit Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Page 2 of 11 Unit Report For 4t Unit Project Pizza Studio Prepared By: 10/07/201 E 11:39AN Unit Parameters Unit Model- 4BKCDA05A2A5.0AOA0 Unit Size' 05 (4 Tons) Volts -Phase -Hertz' 208.3.60 Heating Type Gas Duct Cfg' Vertical Supply / Vertical Return Low Heat Single Stage Compressor Models Lines and Filters Return Air Filter Type- Throwaway Return Air Filter Quantity 2 Retum Air Filter Size: 16 x 25 x 2 Unit Configuration Medium Static Option Belt Drive Al/Cu - Al/Cu Base Electromechanical Controls Standard Packaging Dimensions (ft. In.) & Weight (Ib.) "' Unit Length 6' 2.376" Unit Width- 3' 10.76" Unit Height- 2' 9.375" Total Operating Weight: 719 Ib ••• Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger - Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48KCDA05A2A5-0AOA0 Rooftop Unit 1 Accessories CRECOMZR067A00 Ultra LOW LEAK - Vertical EconoMi$er X with solid-state W7220 controller 1 CRRFCURBOO1A01 14-inch Tall Roof Curb 1 Packaged Rooftop Builder 1.39s Page 3 of 11 sy Certified Drawing for 4t Unit FIELD POWER SNPPL I22] DIA FIELD CO 7.3 /t - ESE] DIA POWER SUPPLY KNOCK-OL Fi 17, 111111111111111111111 11111111II II �111I1I1 II111111IIII Jl l ildlll k 0 CC CO 48K000D281 0 O CU 0) c a_ Certified Drawing for 4t Unit f8 S@Cpg k�S fis.^ S �:S FEL 4. 7. Is CO CC V 0 cc 0 IIIII IIIIIIII III OM IllIMI 1 III IIIUIIIIIIIIII IIIIIIIIIIIII IIIIIIIIIIIIIIIIIII 0 0 0 0 48IC000281 O 0 0 3 O O 0 O u Packaged Rooftop Builder 1.39s Certified Drawing for 4t Unit /\ _ Service Clearance '''''''''''' ..,.......„..,::::,,,z ...,-,1,-4.0 :-...1":. - p yr.. " 1, 'J' a331 z U - Unit disconnect is mounted on panel - No disconnect, convenience outlet option • Recommended service clearance -Minimum clearance -Surface behind sersicer is grounded (e.g.. metal, masonry wall), •Surface behind servicer is electrically non-conductive (e.g., wood, fiberglass) -Cheekier sources of flue products within 10- ft. of unit fresh air intake hood - Side ccndersate drain is used • Minimum clearance • No flue discharge accessory installed. surface is combustible material • Surface behind servicer is grounded (e.g., metal, masonry wall. another unit; • Surface behind sersicer is electrically nor: -conductive (e.g., wood, fiberglass; • Cheekier adjacent units or building fresh air intakes within 10- it. c this units flue outlet NOTE_ Unit not designed to have overhead obstruction. Contact Application Engineering for guidance en any application planning oserhead obstnxtion or vertical clearances. maw 0 0 z 0 V E E E E E.O3! E E 4S-in (1219 min) 424n (1067 mm) _ y o 7 V 0 0-§. c c m^ c , T. 7 ' n m `� m z U 8 Q rD u 0 Page 6 of 11 Packaged Rooftop Builder 1.39s Certified Drawing for 4t Unit gg E a F. 6 R ffi He w0 i V Pi 6 rig w .--, • SUPPLY AIR OPENING �mMI 4,-, am 6ry ry L_ �N SEE VIEW "B" CERTIFIED DRAWING 118 iiEl Igo a 0 p m h 0 O u a~o S N PRODUCTION 3� b 0 1 S y$ 4 Packaged Rooftop Builder 1.39s Performance Summary For 4t Unit Project: Pizza Studio 10/07/201 Prepared By: 11:39AN Part Number:48KCDAO5A2A5-0A0AO ARI SEER 14.00 Base Unit Dimensions Unit Length' 74.4 in Unit Width: 46.8 In Unit Height: 33.4 In Operating Weight Base Unit Weight: 544 Ib Medium Static Option Belt Drive: 10 Ib Accessories Ultra LOW LEAK - Vertical EconoMi$er X with solid-state W7220 controller 60 Ib 14-inch Tall Roof Curb' 116 Ib Total Operating Weight 719 Ib Unit Unit Voltage -Phase -Hertz: 208-3-60 Air Discharge* Vertical Fan Drive Type Belt Actual Airflow: 1600 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB 96.0 F Evaporator Entering Air DB 80,0 F Evaporator Entering Air WB' 67.0 F Entering Air Enthalpy: 31.44 BTU/Ib Evaporator Leaving Air DB• 68.3 F Evaporator Leaving Air WB: 57.4 F Evaporator Leaving Air Enthalpy. 24.67 BTU/Ib Gross Cooling Capacity: 48.73 MBH Gross Sensible Capacity' 37.61 MBH Compressor Power Input: 4.00 kW Coil Bypass Factor 0.148 Heating Performance Heating Air0ow' 1600 CFM Entering Air Temp' 70.0 F Leaving Air Temp. 102.4 F Gas Heating Input Capacity: 72.0 MBH Gas Heating Output Capacity: 0.0 / 56.0 MBH Temperature Rise: 32.4 F Supply Fan External Static Pressure' 0.60 in wg Options / Accessories Static Pressure EconoMi$erlV / EconoMi$e2. 0.07 in wg Total Application Static (ESP + Unit Opts/Ace.). 0.67 in wg Fan RPM- 1107 Fan Power 0.78 BHP NOTE Selected IFM RPM Range: 920 -1303 Electrical Data Voltage Range. 187 -263 Compressor #1 RLA• 13,7 Compressor #1 LRA 83 Outdoor Fan Motor Qty 1 Outdoor Fan FLA (ea) 1,6 Indoor Fan Motor Type' MED Indoor Fan Motor FLA 6.2 Combustion Fan Motor FLA (ea). 0.48 Power Supply MCA 24 Power Supply MOCP (Fuse or HACR) 30 Disconnect Size FLA 23 Disconnect Size LRA: 123 Electrical Convenience Outlet: None Control Panel SCCR: 6kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 85.8 86.5 90.9 125 Hz 79.8 76.8 84.6 250 Hz 71.3 63.1 79.5 500 Hz 67.5 61.5 77.9 1000 Hz 64.1 60.9 76.5 2000 Hz 58.4 54.8 71.1 4000 Hz 59.9 50.2 66.9 8000 Hz 54.8 42.6 82.5 A -Weighted 71.1 Advanced Acoustics 67.0 81.0 HacKaged Koottop builder 1.:39s Page 8 of 11 Performance Summary For 4t Unit Project: Pizza Studio 10/07/201f Prepared By: 11:39AN Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver' 50.0 ft 3. Receiver height above ground: 6.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 260 600 1k 2k 4k 8k Overall A 90.9 84.6 79.5 77.9 76.5 71.1 66.9 62.5 92.4 Lw B 64.7 68.5 70.9 74.7 76.5 72.3 67.9 61.4 80.8 LwA C 58.5 52.2 47.1 45.5 44.1 38.7 34.5 30.1 60.0 Lp D 32.3 36.1 38.5 42.3 44.1 39.9 35.5 29.0 48.4 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, en Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 2.0 1.5 0.5 0.0 00 05 10 15 20 25 30 75 4.0 Airflow (CFM - thousands) RPM=I 07 BHP =0.78 Maximum RPM =2100 Maximum BHP =2.90 Note: Please contact application engineering for selections outside the shaded region. SC • System Curve RP - Rated Point _ `1100 RPM I3l0 RR.1` ,i 1 1 ` t \, IBpp RPM 1' \1700 , 11 \ RRM •'1 1 \ IOW -•M\ I1W RPN 000 RPM 1 \ \ . \ 1 ^� RPM \\. \ \\ \\ \ V.00 OH ,J00RPM I N II 1 . I t 1 \ \:LvP` I' I, I • ENP BHP !V\i I I I)\ I I 1 1 1 1 I I I Packaged Rooftop Builder 1.39s Page 9 of 11 Unit Feature Sheet for 4t Unit 10/07/201 Project: Pizza Studio Prepared By: 11:39Afy %lJ COMPLIANT WeatherMake/ — 48KC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS — 14 SEER u on. 3,4.5TONS WEATHERMAKER SERIES 44/aatherMaker 4SKC (14-SEER) units are one-piece gas heating, electric cooling units that are pre -wired and charged with Puron (R-410) refrigerant. They are factory tested In both heating and cooling modes, and rated in.accordancewith AHRI Standards 2101240. WeatherMaker units are designed in accordance with UL Standard 1995, and listed by the Underwriters' Laboratories. Approved and certified by: us TIFIEOZ' A tAln, riTrt^Q Sk,r:1+ti3rlt!hn go,;zz..sw u, uv ;h try ryte),rt rr. ,S ;`fi t..�.l• Certified to ISO 9001 STANDARD FEATURES INCLUDE: • Pwon :1R-410A) HFC refrigerant • Meets and exceeds ASHRAE.30. 1 energyefficiencylev'e:ts • Scroll compressors with intemaliina:break and overload protection • .Sng3e-stage cooling espact( control • SEER's up to 14.0, EER's up to 12,0 • Aoutroi'"rafrgerantmetering system • Exclusive non -corrosive composite condensate pan in accordance with ASHRAE Standard fit, sloping design. side orcenterdrain • Standard cooling operation up to115'F(46"C)and down to40`F(4'C) - down to 25 F:(-4' C) with winter sto ttu. • Pre -painted exterior panels and primer coated inte:horp aneis tested to 500 h ours salt spray protection • Fury insulated cabinet • Exclusive IGCsoiid-state ocntiol for on -board diagnostics with LED error code designation :burner contro I;og d and energy saving indoor fan motor delay • Lowh0x models that meet Califorra Air auaady Management • Induced d raft gasheet combustion design • Redundant gas vales with up to two stages of heating • Low pressure :and high pressure switoh protected. MAINTENANCE FEATURES: • Acoesspenetswth easy grip handles • Innovative easy starting, no -strip screws on ,unit soca ss panels • Tito -inch disposable return air fitter .end Tool -less filer ac essdoor • Direct Drive - ECM indoormoto:risstandard w;thoptionalbeitdrive systems • TemiinaI board fsciitating simple ssfetycecud troubleshooting and simplified control box arrange • Exclusive Ir3Csolid-.state control for on -board diagnosticsooth LED error code designation, bumeroontrol logic end energy seving indoor fan rnotor delay. INSTALLATION FEATURES: • Thru-thetbottompo,,ter entycapabuty • Single point gas andeiectrio connections • Fun perimeter base renwth bud -in rigging adap ters and forkslots • Field convertible from vertical to horizontal airflow STANDARD WARRANTY: • 10-yearhe.et exchanger -15-year sta inters steal option • 5-yearcompresso:r • 1.year pens • Many optional upgrades also avalfab;e OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • PremierLintand RTUOpen Multi Prot000lDOCControls • Supply and Return Air make Detectors, high :static motors • Louvered condenserooliguards • Disconnectswtch and convenience outlet options • Stainless Steel heate xchangeroption • Corrosion resistant coil coating. • High static motor options • Patented Humidi-MZer` adaptive dehumtdifr ation system. This notion also in oludesMotormsster I controls • Hinged access panels • Integrated eoonomint system. Ste ndardand Uilra Low Leak versions For a complete List of options and Boca ssones refetto the Product Data Catalog forth is unit. Packaged Rooftop Builder 1.39s Page 10 of 11 Spec Sheet for 4t Unit Project Pizza Studio 10/07/201° Prepared By: 11:39AN Packaged Rooftop Builder 1.39s Page 11 of 11 Ell PCS FILE Structural Solutions Seattle Tacoma 811 First Avenue, Suite 620 • Seattle, WA 98104 • tel: 206.292.5076 1250 Pacific Avenue, Suite 701 • Tacoma, WA 98402 • tel: 253.383.2797 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 16 2015 City of Tukwila BUILDING DIVISION www.pcs-structural.com STRUCTURAL CALCULATIONS AND DETAILS FOR PIZZA STUDIO SOUTHCENTER ROOFTOP HVAC SUPPORT TUKINILA, WASH INGTON PREPARED BY PCS STRUCTURAL SOLUTIONS CORRECTION LTR#. RECEIVED CITY OF TUKWILA NOV 0 9 2015 PERMIT CENTER SEPTEMBER 25, 2015 15-510.01 tAlq•01)92 a PCS Structural Solutions Project: PralAT S1 D t A-C. Job No. / ,5-c- G lc�,/a Subject: Sheet 1 Name. L�1411 Originating Office: ❑ Seattle ❑ Tacoma (GIsQ t'JV151�`" '41 T6'-3" O.C. (E) 44" JOIST GIRDER MEGH UNIT - MAX. WT. SOO# (E) 26" K JOISTS J Date 9 / "r A I/4 TYP. GUT CUT (E) MTL DECK A5 NEED D e (ThPARTIAL ROOF FRAMING PLAN 3/32"= I'-O" Seattle Tacoma 811 First Avenue, Suite 620 • Seattle, WA 98104 • tel: 206.292.5076 www.pcs-structural.com 1250 Pacific Avenue, Suite 701 -Tacoma, WA 98402 • tel: 253.383.2797 a PCS Project: PIQ e 1. 0 Vi 4tC" Job No I��7'1G� d 1 Subject Sheet Name• r ?€ f Structural Solutions Originating Office: ❑ Seattle ❑ Tacoma Date• 9/ 1 j c7 L4x4 ANGLES ±6'-O" TO (E) JOIST GIRDER I/SV DETAIL n=1I_O" IS GA. MECH UNIT CURB #IO SELF TAPPING SCREWS @ 6"O.G. AT PERIMETER OF MEGH UNIT. (E) MTL DECK (E) STL JOIST PANEL POINT - IF NO PANEL POINT EXISTS, CONTACT ENGINEER FOR DIRECTION Seattle 811 First Avenue, Suite 620 • Seattle, WA 98104 • tel: 206.292.5076 www.pcs-structural.com Tacoma 11250 Pacific Avenue, Suite 701 • Tacoma, WA 98402 • tel: 253.383.2797 Project: �`1 VDNd C�v Job No- 1 S 'GJt �) •.111 RS Subject: Sheett 3 Name a-EW M Structural Solutions Originating Office: El Seattle ❑Tacoma Date• 9/z /i5 #IO SELF TAPPING SCREWS @ 6"0.G. AT PERIMETER OF MECH UNIT. (E) MIL DECK L2Y2x2Y2xI/4xO'-6" (E) JOIST GIRDER f DETAIL IS GA. MEGH UNIT CURB t-Y2' MAX. L4x4 ANGLE I/S V Seattle lacoma 811 First Avenue, Suite 620 • Seattle, WA 98104 • tel: 206.292.5076 www.pcs-structural.com 1250 Pacific Avenue, Suite 701 • Tacoma, WA 98402 • tel: 253.383.2797 pcs Project: ��4-9.rUt tD Job No•-I1b,Of Subject: Sheet Name" AA Structural Solutions Originating Office: ❑ Seattle ❑ Tacoma Date- eis" 23 /N/A•c st.dr2 'c4D UN ra' Wor ;, l b ►4 (e))‘A iJr.n ifut, /•tom, 62,40 U r Ta two 16 l,J €A 56,41. �-- pt> u,.ovs 144Yr P Prz i a`log/ r-1 t. i 0 _ 51W7.J Seattle 811 First Avenue, Suite 620 • Seattle, WA 98104 • tel: 206.292.5076 Tacoma 1250 Pacific Avenue, Suite 701 • Tacoma, WA 98402 • tel: 253.383.2797 www.pcs-structural.com Project: �V'Dl� O.b1 a PCS Subject: �Sheet Job No• ' `, Name: Structural Solutions Originating Office: ❑ Seattle ❑ Tacoma Date- 9 Z3 `) C✓ Seattle Tacoma toot* x34c/ FAX MKI LJl`f ►Mlc0.9 ,,,, cat caauertd P tvt Carr. x`7 f+ro,ZCi' �3 30; tl . ` r o,%fokv►3 L4k4,cl'41. rA Il.4°6 -,re-d._o►i L.�4-kd-x�4 ,q't-i VW,U'1 ,M Swv1R lam%' lc 44- LA 1t-t .ram I8GA- C)23 -TO '2 -1,4A 5 e ve tA't' t t` T 811 First Avenue, Suite 620 • Seattle, WA 98104 • tel: 206.292.5076 www.pcs-structural.com 1250 Pacific Avenue, Suite 70]. •Tacoma, WA 98402 • tel: 253.383.2797 P tea : Ln S ,tJJ �/A+,►..Y 9c Srom ass �'r r�, ► �► D - C,A Screw and Weld Capacities Screw Capacities Table Notes 1. Capacities based on AISI S100 Section E4. 2. When connecting materials of different steel thicknesses or tensile strengths, use the lowest values. Tabulated values assume two sheets of equal thickness are connected. 3. Capacities are based on Allowable Strength Design (ASD) and Include safety factor of 3.0. 4. Where multiple fasteners are used, screws are assumed to have a center -to -center spacing of at (east 3 times the nominal diameter (d). 5. Screws are assumed to have a center -of -screw to edge -of -steel dimension of at least 1.5 times the nominal diameter (d) of the screw. 6. Pull-out capacity is based on the lesser of pull-out capacity In sheet closest to screw tip or tension strength of screw. 7. Pull -over capacity is based on the lesser of pull -over capacity for sheet closest to screw header or tension strength of screw. 8. Values are for pure shear or tension loads. See AISI Section E4.5 for combined shear and pull -over. 9. Screw Shear (Pss), tension (Pts), diameter, and head diameter are from CFSEI Tech Note (F701-12). 10. Screw shear strength is the average value, and tension strength is the lowest value listed in CFSEI Tech Note (F701-12). 11. Higher values for screw strength (Pss, Pts), may be obtained by specifying screws from a specific manufacturer. Thickness Deslgn Yleld (Mils) Thickness (w) TenFu sile (ksl) (Pss = 643Ibs, 0.138" Shear 46Screw Pts dia, 0.272" Pull -Out Allowable .419lbs) Head Pull -Over (Pss=1278Ibs, 0.164" Shear Screw #8Screw Pts dia, 0.272" Pug -Out Connection • 686Ibs) Head Puft.Over Capacity (Pss=1644Ibs, 0.190" Shear #10Screw Pls. dia, 0.340" Pull -Out (Ibs) 1168Ibs) Head Pull•Over (Pss• 2330Ibs, 0.216" Shear #12Screw Pts • dia, 0.340" Pull -Out 23261bs) Head Pu1I.0ver (Pss■ 3048 0.250" Shear 'W'Screw Ibs, Pts • dia, 0.409" Pull -Out 3201 Ibs) Head PuII.Over 18 0.0188 33 33 44 24 84 48 29 84 52 33 105 55 38 105 60 44 127 27 0.0283 33 33 82 37 127 89 43 127 96 50 159 102 57 159 110 66 191 30 0.0312 33 33 95 40 140 103 48 140 111 55 175 118 63 175 127 73 211 33 0.0346 33 45 151 61 140 164 72 195 177 84 265 188 95 265 203 110 318 43 0.0451 33 45 214 79 140 244 94 195 263 109 345 280 124 345 302 144 415 54 0.0566 33 45 214 100 140 344 118 195 370 137 386 394 156 433 424 180 521 68 0.0713 33 45 214 125 140 426 149 195 523 173 386 557 196 545 600 227 658 97 0.1017 33 45 214 140 140 426 195 195 548 248 386 777 280 775 1,016 324 936 118 0.1242 33 45 214 140 140 426 195 195 548 301 386 777 342 775 1,016 396 1.067 54 0.0566 50 65 214 140 140 426 171 195 534 198 386 569 225 625 613 261 752 68 0.0713 50 65 214 140 140 426 195 195 548 249 386 777 284 775 866 328 948 97 0.1017 50 65 214 140 140 426 195 195 548 356 386 777 405 775 1,016 468 1,087 118 0.1242 50 65 214 140 140 428 195 195 548 388 386 777 494 775 1,018 572 1,087 Weld Capacities Table Notes 1. Capacities based on the AISI S100 Specification Sections E2.4 for fillet welds and E2.5 for flare groove welds. 2. When connecting materials of different steel thicknesses or tensile strengths, use the lowest values. 3. Capacities are based on Allowable Strength Design (ASD). 4. Weld capacities are based on E60 electrodes. For material thinner than 68 mil, 0.030" to 0.035" diameter wire electrodes may provide best results. 5. Longitudinal capacity is considered to be loading in the direction of the length of the weld. 6. Transverse capacity is loading in perpendicular direction of the length of the weld. 7. For flare groove welds, the effective throat of weld is conservatively assumed to be less than 2t. 8. For longitudinal fillet welds, a minimum value of EQ E2.4-1, E2.4-2, and E2.4-4 was used. 9. For transverse fillet welds, a minimum value of EQ E2.4-3 and E2.4-4 was used. 10. For longitudinal flare groove welds, a minimum value of EQ E2.5-2 and E2.5-3 was used. Thickness (Mils) Deslgn Thickness Fy yield (ksl) Allowable Weld Fu Tenslle (ksi) Capacity (Ibs / in) FIOelWelds Longitudinal Transverse Flare Groove Longitudinal Welds Transverse 43 0.0451 33 45 499 864 544 663 54 0.0566 33 45 626 1084 682 832 68 0.0713 33 45 789 1365 859 1048 97 0.1017 33 45 1125 1269 -' -' 54 0.0566 50 65 905 1566 985 1202 68 0.0713 50 65 1140 1972 1241 1514 97 0.1017 50 65 1269 1269 •' -' 'Weld capacity for material thickness greater than 0.10-requires engineering judgment to determine /eg of welds, WI and W2. 70 www.S.SP4A.com Copyright © 2014 by the SSMA 1 Carrier y United Technologies SUBMITTAL Pro et Pizza Station Date Thursday, September 10, 2015 Contractor CFM Heating & Cooling C FM HEATING & COOLING, INC F'i=: A- S o t5-5io or) fill an'' )KYR, 4t Unit Prolate Flora station Prepared By: o4rtonot: as: 4t Unit Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.39s Page 2 of 11 Unit Report For 4t Unit Project Pizza Station 09/10201: Prepared By 08:35A1u Unit Parameters Unit Model 4 Unit Size8KCDAOSA2A5-0AOAO :............... ....._._.....................05 (d Tons) VolIs-Phase•Hertz:.....................................200 3•60 Healing Type. Gas Duct Cfg• Vertical Supply 1 Vertical Return Low Heat Single Stage Compressor Models Lines and Filters Return Nr Faller Type:...,.,_.....„.,...,._._Throwaway Return Nr Filter Quantity:... ............................. ..::.. 2 Retum Nr Filler Size: ...... .......... _...._..... 16 x 25 x 2 Unit Configuration Medium Static Optim Belt Drive N/Cu - Al/Cu Base Electromechanical Conbds Standard Packaging Dimensions (fL In.) 8 Weight (Ib.) ••' Unit Length' 6' 2.375' Unit Width' 3' 10.75' Unit Height 2' 9.375' Total Operating Weight 719 Ib ••• Weights and gm.ndms .n approximate, Weight does nol Include oMt p.<k.ging. Approdm.lo dlm.n.kn..re pro.M.d primarily for.Mpping purpor., For exert dgn.n.bns end might., WO, to appropriate productd.to< .log. Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger - Numinized(std. ) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Numbor Description _ Quanttty 1 a8KCDA05A2A5-0AOAO Rooftop Unit Accessories CRECOMZR067A00 Ultra LOW LEAK - Vertical EconoMiSer X Wtth solid -slate W7220 controller 1 CRRFCURB001A0t 14.inch Tatl Roof Curb 1 Packaged Rooftop Builder 1.39s Page 3 of 11 Jo Certified Drawing fer 4t Unit Prcjsd: pun SUS. Prsperul BY. 0W052O 010.5.M. BSI I��Ir11 ulF 11 i�il V(Iffi 111..IPf Irn Oa 114 Mt u h. 1_C h.cl. Illrn I�11fi1 . I.0*51. Priu t�7ylfltii.alniF. i1 FRONT Xg ariti?,i :fir = tvi'II0. 11111 rnn O. uc mt. nrn1.At i Ytw.e 'CC. nnr rlonat imaiml d Q I IrY 1. art In ((VIM . 1 r/l ' 11+11f. rM1 WI..h+[r-NI IIr SI IQIIr+5WI111A l01I n( 141�n1+1. . +PHileu.ir UmUll furl IIll t -..rca. `ii "—F.4-.' rP 1...1.1•rr4.P' II(Iu( InnKl rP Ptr i,r, + [. rY.ililt f110 IIM+ 10..q IW Iv r.n., BR 1N .1111 Iln S1' MIf(4 r (nr I llfi !rl tut I01.14 1A 1t.:C 04 0f 51p0LC 101,1 IICCl0ICAt COOLIttG nut GAS Hit.t 81(C0O0d61 Packaged Rooftop Builder 1.39s Page4 of 11 !1 Certified Drawing for 4t Unit PReNndelt OM1OR01: 1Ae,0.is i{tn1iA, Irr ttp,lr 1{ „t t s 1 „ es ,t 1 .i unman 7r , n Aa Va eAT NIA Ht[s1dA Ai[Ifi ete tgro ectV4u CO(AXA A CORNER 0 �tls Al[ARlls 1�� CORNER TOP CORNER C [boo C-7' ter_=D. : oop TAM a A 9.14 I/ +AEC 0T 04 bINOtt PONE EIVIN0CAl. COOT IRO 0LI* 0LRS NI:AI Packaged Rooftop Builder 1.39s Page 50(11 12 0140Pz.Station Istipsetd 4a Certified Drawing for dt Unit O&IO2aY. Service Clearance LOCO.. ttmrravtve <fltBi tali A Ileiva mml • alctel l8ia IaSTtrn} rlo drs<WNt.<ameNtt<e MM Colon • nxr uncle remade/rime tnaasl-m< •wrolvm e deatan B i at nlecettrni •vb.t t<I:41511 14n;1et •eele}.mnI 144ul nay ten7:u tent •kAe;•he)i'(.ttn*enit'n-rgtil reu.<vhttp+tfe.,6161. lte.tiaasl .t t«e<n CO t>a<g.mn(. nIeM:0 1.:1.n� h..I II relit tun al t 1:<iel-tea_ 4 1t4 •w1L4.Yme(onfN e.nid O III, Tr: l1 ml . ryr:ntalxe.tosw lc1 dsnlijt maa1mere No abren6AYN.,gsee ttt 114.431.n1, meantf1< rurel . .¢netebew•1:erkert5 ehNl669_cmn%?.<4ie.t.. .taifel Specul •tIvta.. lirjuee;urt<. b*nq Ant,. rtili, 6n:P6<l,.., ve,, Nye,. 11.1..4t<•p d!,imd.ebv r ntil:ea, ilt•ru:et Et n.:1 aj0:e:ae.. tr<unty appkt'N0 Aan.tg oterh.ad tb tnotlon b. nkrl tkerarKes Packaged Rooftop Builder 1.39s Page edit 13 Certified Drawing for 4t Unit Prv1.a P Smtlan PrapYra3eY. oaioaoi: =I_ n�iN p1nmEn. *fold..Ir.rq,QEaa+'. tx l I On. W Yu)arErm Nt+Actor • r E Er uH uu+suc. tc4trtf�Y:f iflmirwnmiwiuiEEmiiMMlMe Gaco tclwro VIEW'B' XV.:a L'c waceeo'.0 i:tor s •A OAS ran. CainotIRRIRS ACCESSORYCCIRMIRME at1.1 art +�arnr.r ✓nAa +gaol •sire ti WeivhtW rclei✓naee1 IRK SEE VIEW if IOSIRR CERTIFIED DRAWING .«... ui........ PRODUCTION CURB ASV, ROOF •a48TC4ODa2'7j'i::..•e Packaged Rooftop Builder 1.39s Page 7 of 11 I It Performance Summary For 4t Unit Project: Pizza Station 09/10201,1 Prepared By: O8:35AA Part Number:48KCDA05A2A5-0A0A0 Aid.SEER:........................................................................................................_.........,.-...,.. Base Unit Dimensions Unit Length' 74.4 in Unit Width: 46.8 in Unit Height: - 33.4 in Operating Weight Base Unit Weight: Medium Static Option Belt Drive: 544 lb 10 Ib Accessories Ultra LOW LEAK- Vertical EconoMi$er X with solid -stale W7220 controller 50 Ib 14inch Tall Roof Curb' - 115 Ib Total Operating Weight 719 Ib Unit Unit Voltage -Phase -Hertz: 208.3.60 Air Discharge' ... Vertical Fan Drive Type' - Belt Actual Airflow. 1600 CFM Site Altitude* 0 R Cooling Performance. Condenser Entering Art DBt...... 95.0 F Evaporator Entering Air DE' 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy 31,44 BTU/lb Evaporator Leaving Air Da ............................... 58.3 F Evaporator Leaving Air W& 57.4 F Evaporator Leaving Air Enthatpy, 24.67 BTU/lb Gross Coding Capacity: , 48.73 MBH Gross Sonsibie Capacity: 37.51 MBH Compressor Power Input - 4.00 kW Coil Bypass Factor 0.146 Heating Performance Healing Airtbw 1600 CFM Entering Air Temp' 70.0 F Leaving Air Temp' 102.4 F Gas Heating Input Capacity: 72.0 MBH Gas Healing Output Capacity 0.0 / 56.0 MBH Temperature Rae' 32.4 F Supply Fan External Static Pressure' 0.50 in wg Options / Accessories Static Pressure EconoMi$erlV / EconoMi$e2: 0.07 in wg Total Application Static (ESP + Unit Opls/Acc.)' 0.57 in wg Fan Power 0.78 BHP NOTE Selected IFM RPM Range: 920.1303 Electrical Data Voltage Range:. 167 - 253 Compressor #1 RLA ... 13.7 Compressor#1 LRA 83 Outdoor Fan Motor Qty. 1 Outdoor Fan FLA (ea)• 1.5 Indoor Fan Motor Type' MED Indoor Fan Motor FLA: 5.2 Combustion Fan Motor FLA (eat 0.48 Power Supply MCA' 24 Power Supply MOCP (Fuse or HACR)' 30 Disconnect Size FLA _...,._ 23 Disconnect Size LRA: 123 Electrical Convenience Outlet' None Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 85.8 86,5 90.9 125 Hz 79.8 76,8 84.6 250 Hz 71.3 63.1 79.5 500 Hz 67,5 61.5 77.9 1000 Hz 64,1 60,9 76.5 2000 Hz 58.4 54.8 71.1 4000 Hz 59.9 502 66.9 8000 Hz 54,8 42,6 62.5 A -Weighted 71.1 67.0 81,0 Advanced Acoustics Fackagea ttooltop builder 1. 3Ms Page 8 of 11 15 Performance Summary For 4t Unit Project: Pizza Station 09/10201! Prepared By.'. _. 08:35A% Advanced Accoustics Parameters 1. Unit height above ground" „ . 300 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground' 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver0.0 ft 6. Horizontal distance from unit 10 obstruction" 0.0 ft Detailed Acoustics information Octavo Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 90.9 84.6 79.5 77,9 76.5 71.1 66.9 62.5 92.4 Lw B 64.7 68:5 70.9 74.7 76.5 72.3 87,9 61 A 80.8 LwA C 58,6 522 47.1 45,5 44.1 38.7 34.5 30.1 60,0 LA D 32.3 36.1 38.5 42.3 44.1 39.9 35.6 28.0 48.4 WA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program ere pattemed after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable In the ad c4 system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied Input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 2.0 15 0.5 00 00 05 10 t5 20 as 1.0 15 40 Airflow (CFM - thousands) RPM= 107 BHP =0,78 Maximum RPM=2100 Maximum BIiP=2.90 Note: Please contact application engineering for selections outside the shaded region. SC - System Curve RP - Rated Point 1lnn mull -1 i:a raw 1 11twaM1M ' A '1 \, \. moo'. 1L9D- .1rMpFu 5S 1 i /Oa RNA 011ry r.100Q10 ]reRru -J-1-1-1_ .,f / _Li_JJJ .\ 1. .` OFA&V ., J 1-LI roarr 1 r514V _JJ...1-.1. _1. 1 t I 1 1 I 1 _4J_1 f -11-L.- Packaged Rooftop Builder 1.39s Page 9 of 11 Unit Feature Sheet for 4t Unit ProjecLPizza Station 09110/201/ Prepared By: 08:35Ab II$H'ME COMPLIANT — 48KC rMak r• Weathe e PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS —14 SEER Pfir uron. 3, 4,5 TONS WEATHERMAKER SERIES WeatherMaker 48KC (14-SEER) units are one-plece gas heating, electric cooling units that are pre -wired and charged with Puron (R-410) refrigerant. They are factory tested in both heating and cooling modes, and rated in accordancewith AHRI Standards 210/240. 'A'eatherMaker units are designed in accordance with UL Standard 1995, and listed try the Underwriters' Laboratories. Approved and certified by: A}} ICERIIFIED- UV Certified to ISO 9001 STANDARD FEATURES INCLUDE: • Puron (R-410A) HFC refrigerant • Meets and exceeds ASHRAE 90,1 energyeffiooncy levels • Scroll compressors with internal line break and overload protection • Single -stage coolingcapeo'nycontrol • SEEK' up to 14.0, EER's up to 12.0 • Acutrol"' refrigerant metering system • Exclusive non-conoshe composite condensate pan in accord once with ASHRAE Standard 62, sloping design. side or centerdrain • Standard cooEng operation up to 115'F (46'C)and down to 40'F(4'C) - down to 25' F (-4' C) with winter start kit. • Pre -painted exterior panels end primer -coated interior panes tested to 500 hours sett spray protecka n • Fully insulated cabinet • Exclusive IGC sold -stele control for on -board diagnostics with LED error codedesrgnation bumeroontrol logic and energy asvmg indoor fan motor delay • Low NOx models that meet Ce ldocols Air Oualty Management • Induced draftgas hest combustion design • Redundant gasvatoeswdh ua to too stages of heating • Low pressure and high pressure switch protected. MAINTENANCE FEATURES: • Access panetswah easygnp handles • Innovative easy startingno-strip screw_ on u nil sods ss panels • Two-inch di;possble return aufilers snd Tool -less filar access door • Direct Drive — ECM indoor motor is standard with optionalbel drive systems • Terminal board facddating simple ssfetycircurt troubleshooting and simplified control box soigne ment • Exclusive IGC sold -state controlfor on -board dragnostxsw.h LED error code designation, burner control bgio and energysavrng indoor fan motor delay INSTALLATION FEATURES: • Thru-the-bodom power enfrycapabd1y • Single point gas and electric connections • Full perimeter b s se rain with bul-in rigging ads pies and fork slots • Frey convertible fromvertx:alto honzontslsirfaw STANDARD WARRANTY: • 10-year hest exchanger— 15-year stainless steel option • 5-yearcompressor • 1-year parts • Many oplmnal upgrades a150 9Ysiiabte OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • Premiert.ink and RTU Open Multi ProtocolDDC Controls Suppty-and Return Air Smoke Detectors. high stolenoto • Louveredoondensercorlgusrds • Disconnect switch and convenience outlet options • Stainless Steel hesterchhngeropibn • Corrosion resistantcoil costing. • High static motor options • Patented H,, sti-142er` adaptive dehunedlfoalion system.Ths option also includes kilo toimester Icontrols • Hinged acoesspa nets • Integrated economizer system. Stsndsrd and Uars Low Lesk versions For a compute list of options and accessories reefer to the Product Data Catalog tar this unit Packaged Rooftop Builder 1.39s Page 10 of 11 17 Project: Pizza Station 09/10R01; oe:35AM Prepared eV: Spec Sheet for 4t Unit Packaged Rooftop Builder 1.39s Page 11 of 11 City of Tukwila Department of Community Development October 26, 2015 JEREMY MOELLER PO BOX 3205 KIRKLAND, WA 98083 RE: Correction Letter # 1 MECHANICAL Permit Application Number M15-0133 PIZZA STUDIO - 17250 SOUTHCENTER PWKY, SUITE 148 Dear JEREMY MOELLER, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" to be stamped and signed. [Electronic copies shall not be approved.] (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Provide plans and documents stamped and signed as specified in the General Note above. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 433-7165. Sincerely, Rachelle Ripley Permit Technician File No. M15-0133 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0133 DATE: 11/19/15 PROJECT NAME: PIZZA STUDIO SITE ADDRESS: 17250 SOUTHCENTER PKWY - SUITE 148 Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued X Revision # 1 after Permit Issued DEPARTMENTS: Building Division 111 Public Works �rn Pr12- Fire Prevention Structural Planning Division Permit Coordinator ip PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 11/24/15 Structural Review Required R.EVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 12/22/15 Notation: PIA REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0133 DATE: 11/10/15 PROJECT NAME: 11€1A PII i z S1- S i' D SITE ADDRESS: C1)-5oU4LrI -4 Had Revision # before Permit -Issued Original Plan Submittal X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: kr- c \1--\3I3_ Building Division MI Public Works ❑ Fire Prevention Structural n Planning Division Permit Coordinator El PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 11/10/15 Structural Review Required DATE: El APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 12/08/15 PAIL REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PROJECT NAME: IUA S SITE ADDRESS: PERMIT NO: in I ORIGINAL ISSUE DATE: ii/IO/i REVISION LOG REVISION NO. DATE RECEIVED STAFF INfflALS ISSUED DATE STAFF INITIALS 1 Ift Summary of Revision: mc Qf �j Q1W ,n( l Received :ice{ hi/AA V REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS ' Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: II:- b /`' Plan Check/Permit Number:M 15-0133 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: PIZZA STUDIO Project Address: 17250 SOUTHCENTER PKWY #148 f$ / Contact Person: ��;(�/ f 1C 1( Phone Number: ,l 2SO-l `/, 4.30 Summary ofRevision: k-\- �S�civ £Of eS b `iyne ,`-r t ,4cya I erg �'�e'er .dc, icil i. ✓t co /nc(vcl - �J RECEIVED CITY OF Tl."l W. 4IA NOV 0 9 2015 Sheet Number(s): "Cloud" or highlight all areas of revision including date o Received at the City of Tukwila Permit Center by: ❑ Entered in TRAKiT on W:\Permit Center\Templates\Forms\Revision Submittal Form.doc Revised: August 2015 evisio t PLAN REVIMOPUTING SLIP PERMIT NUMBER: M15-0133 DATE: 10/09/15 PROJECT NAME: PIZZA STUDIO SITE ADDRESS: 17250 SOUTHCENTER PKWY, SUITE 148 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AT COv L I01O 1 S A1,/t Dk \14 Building Division Fire Prevention Public Works Structural Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/15/2015 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/12/2015 Approved Corrections Required n Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: (5 Plan Check/Permit Number: V 5-133 Response to Incomplete Letter # Response to Correction Letter # Revision # 1 after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Ii Zzrn��;V Project Address: 132.5o y Contact Person: 3Pf(€O.9 Adler Summary of Revision: p; zx4 6lg-A Phone Number: stz5 Gad ►n5ed G x t dL ttbot . ( 2- kc d ow r (h oleel 40 a,ski?yivan; ZJ 61e01, L xt' lU5 Q veyba m115 ct1(c. 6n plans requOti , 2 tAt0A Olte 6Leil Sheet Number(s): 1"'0° 0 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 1 I ` i •- i ,- .oks 661 i5 ob4- flt; '19 201t PERMIT CENTEA H.\Applications\Forms-Applications On Line\2010 Applications\7-2010 - Revision Submittal.doc Revised: May 201 I C F M HEATING AND COOLING 'NC Page 1 of 2 Home lnicio en Espanol Contact Search L&I a-"ZIndex Help it 4Iy Secure 1: &1 Safety Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries C F M HEATING AND COOLING INC Owner or tradesperson Principals CLANCY, SHAUN P, PRESIDENT Doing business as C F M HEATING AND COOLING INC WA UBI No. 602 361 244 PO BOX 3205 KIRKLAND, WA98083 425-821-1293 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. CFMHEHC969CD Effective — expiration 02/04/2004— 02/04/2016 Bond ................. DEVELOPERS SURETY & INDEM CO Bond account no. 798903C Active. Meets current requirements. $12,000.00 Received by L&I Effective date 12/17/2008 02/04/2009 Expiration date Until Canceled Insurance ............_............. AMERICAN FIRE & CASUALTY CO Policy no. BKA54333410 $1,000,000.00 Received by L&I Effective date 01/22/2015 02/04/2011 Expiration date 02/04/2016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ......................................................... No license violations during the previous 6 year period. � I https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602361244&LIC=CFMHEHC969CD&SAW= 11/18/2015 ABBREVIATIONS AC AD AFC AFF AHU AL BDD BFC BHP BI BOD BTU BTUH CFM CV CW CRD AIR CONDITIONING ACCESS DOOR ABOVE FINISHED CEILING ABOVE FINISHED FLOOR AIR HANDLING UNIT ALUMINIUM BACK DRAFT DAMPER BELOW FINISHED CEIUNG BRAKE HORSE POWER BACKWARD INCLINED BOTTOM OF DUCT BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR CUBIC FEET PER MINUTE CLEAN OUT CONSTANT VOLUME COLD WATER CEILING RADIATION DAMPER DIA DIAMETER DIM DIMENSION DMPR DAMPER DN DOWN DP DIFFERENTIAL PRESSURE DWG DRAWING EX EXISTING EAT ENTERING AIR TEMPERATURE EF EXHAUST FAN EFF EFFICIENT, EFFICIENCY EG EXHAUST GRILLE ELEC ELECTRICAL FG FLOOR GRILL FD FIRE DAMPER F FURNACE FPM FEET PER MINUTE FSK FOIL SKRIM KRAFT LINER (SPUNSTRAND) FT FEET, FOOT G GAS GR GRILLE HP HORSE POWER HR HOUR HTG HEATING HVAC HEATING, VENTIALTION AND AIR CONDTIONING HW HOT WATER ID IN INFO INSUL INSIDE DIMENSION INCH, INCHES INFORMATION INSULATE, INSULATION JAN JANITOR KW KILOWATT KWH KILOWATT HOUR LAT LEAVING AIR TEMPERATURE LF UNEAL FEET LVG LEAVING MA MIXED AIR MBH THOUSAND BRITISH THERMAL UNITS PER HOUR MAT MIXED AIR TEMPERATURE MAX MAXIMUM MECH MECHANICAL MFG MANUFACTURER MED MEDIUM MIN MINIMUM, MINUTE MISC MISCELLANEOUS NORTH NA NOT APPLICABLE NTS NOT TO SCALE OSA OUTSIDE AIR OAT OUTSIDE AIR TEMPERATURE OD OUTSIDE DIMENSION OPP OPPOSITE OV OUTLET VELOCITY PD PRESSURE DROP PERF PERFORATED PF PRE FILTER PH PHASE QTY QUANTITY RA RETURN AIR REQD REQUIRED RET RETURN RPM REVOLUTIONS PER MINUTE RG RETURN GRILLE MECHANICAL SPECIFICATION GENERAL SCOPE THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL MECHANICAL SYSTEM. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO COMPLETE THE MECHANICAL WORK. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW OFFSETS WHICH MAY BE REQUIRED. SITE EXAMINATION THE MECHANICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, DUCTWORK, AND PIPING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER. INSTALLATION OF THE MECHANICAL WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ARL, ASME, ASTM, UL, NEMA, ANSO, SMACNA, ASHRAE, NFPA, AS APPUCABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE MECHANICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO THE OWNER. PERMITS AND FEES THE MECHANICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE MECHANICAL WORK. WARRANTY THE MECHANICAL CONTRACTOR SHALL UNCONDITIONIALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY OWNER, AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND SHALL RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. DUCTWORK AND ACCESSORIES SHEET METAL DUCTWORK ALL DUCTWORK TO BE RIGID SHEET METAL CONSTRUCTED FROM GALVANIZED SHEET STEEL IN ACCORDANCE WITH SMACNA LOW VELOCITY DUCT CONSTRUCTION STANDARDS. ALL EXPOSED DUCTWORK TO BE ROUND, SPIRAL, LOCK SEAM TYPE. ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AIR TIGHT (8% LEAKAGE) AND NOISELESS (NO OBJECTIONABLE NOISE) SYSTEMS CAPABLE OF PERFORMING EACH INDICATED SERVICE. FURNISH ALL DAMPERS, TRANSITIONS, CONNECTIONS TO AIR TERMINALS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE OPERATING SYSTEM. NO VARIATION OF DUCT CONFIGURATION OR SIZES WILL BE PERMITTED EXCEPT BY PERMISSION FROM THE ENGINEER. PROVIDE LEAK TEST IF REQUIRED BY DPD DUCT SEALANT SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS WITH A NON —HARDENING, NON —MIGRATING MASTIC OR LIQUID ELASTIC SEALANT OF A TYPE RECOMMENDED BY THE MANUFACTURER FOR SEALING JOINTS AND SEAMS IN SHEET METAL DUCTWORK. COVER ALL FIELD JOINTS, JOINTS AROUND SPIN —IN FITTINGS, AND FASTENING SCREWS WITH MASTIC. SUPPORTS: PROVIDE HOT —DIPPED GALVANIZED STEEL, FASTENERS, ANCHORS, RODS, STRAPS, TRIM, AND ANGLES FOR SUPPORT OF DUCTWORK. PROVIDE SEISMIC BRACING FOR HEAT PUMPS IF REQUIRED BY DPD DAMPERS PROVIDE OPPOSED —BLADE, MULTI —LEAF VOLUME CONTROL DAMPERS WHERE INDICATED ON DRAWINGS AND AT POINTS ON LOW PRESSURE SUPPLY, RETURN, AND EXHAUST DUCTS WHERE BRANCHES ARE TAKEN FROM LARGER DUCTS. PROVIED UL USTED FIRE DAMPERS WHERE REQUIRED AND IN ACCORDANCE WITH NFPA AND LOCAL CODES. PROVIDE CONVEINIENTLY LOCATED ACCESS DOORS OF AMPLE SIZE AND QUANTITY FOR SERVICING THE DAMPERS. PROVIDE DAMPERS AT ALL BRANCH LINES AND TAKE —OFFS. GRILLES, REGISTERS & DIFFUSERS GRILLES, REGISTERS, AND DIFFUSERS SHALL BE INSTALED AS INDICATED ON THE DRAWINGS AND SCHEDULES. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS ITEMS NECESSARY FOR A COMPLETE AND PROPER INSTALLATION IN THE TYPE OF CEIUNG AND WALLS USED IN THIS PROJECT. THERMAL INSULATION PROVIDE EXTERNAL THERMAL INSULATION WITH AN INTEGRAL VAPOR BARRIER FACING OF SUFFICIENT THICKNESS TO MEET LOCAL ENERGY CODE REQUIREMENTS. PROVIDE INSULATION ON EXHAUST AND OUTSIDE AIR DUCTS, AND ON CONCEALED PORTIONS OF SUPPLY AND RETURN AIR DUCTS. DO NOT INSULATE EXPOSED DUCTWORK AND PORTIONS OF DUCTWORK THAT ARE INTERNALLY LINED. THERMAL INSULATION TO COMPLY WITH AN NFPA FLAME SPREAD OF 25 OR LESS, AND SMOKE DEVELOPED NO GREATER THAN 50. ACCOUSTICAL DUCT LINER: UNLESS OTHERWISE INDICATED ON THE PLANS, PROVIDE 1" GLASS FIBER ACCOUSTICAL DUCT LINER ON SUPPLY AND RETURN DUCTWORK WITHIN 10 FEET OF THE DISCHARGE AND INTAKE OF AIR HANDLING UNITS. INCREASE DUCT SIZE INDICATED ON PLANS 2" IN EACH DIMENSION TO ACCOMODATE LINER. PACKAGED ROOFTOP AC UNIT SCHEDULE MARK MAKE MODEL CFM SP. COOLING HEATING ELECTRICAL WEIGHT ECONOMIZER SOUND TOTAL SENS SEER INPUT OUTPUT AFUE% DATA FUSE M.C.A. AC-1 CARRIER 48KCDA05A2A5-0A0A0 1600 .50" 48.73 37.51 14.00 SEER 72.0 56.0 80.0 208-3-60 30 24 719 LBS. YES 81.0 dBA FAN SCHEDULE SYMBOL MAKE & MODEL SERVES CFM SP RPM MOTOR ELECT. TYPE WEIGHT BDD NOTES EF-1 PANASONIC FV08Q53 WOMEN'S RESTROOM 108 80 0.5" 779 120-1-60 CEILING 12 LBS YES VENT TO ROOFCAP 21.2 WATTS EF-2 PANASONIC FV08Q53 MEN'S RESTROOM 107 80 0.5" 779 120-1-60 CEILING 12 LBS YES VENT TO ROOFCAP 21.2 WATTS EF-3 ILG CRBA 10 PIZZA DECK OVEN 623 0.5" 1503 1/4 HP 115-1-60 ROOFTOP 115 LBS NO SERVES PIZZA OVEN HVAC NOTES: 1. EF-3 IS TO BE INTERLOCKED WITH AC-1 FOR MAKE UP AIR (600 CFM PROVIDED FOR MAKE UP AIR) 2. TYPE 2 HOOD CONSTRUCTION IS 24 GAUGE STAINLESS STEEL AND DUCTWORK CONSTRUCTION IS 26 GAUGE GALVANIZED STEEL 3. EF-3 MUST TERMINATE A MIN. OF 30" ABOVE ROOF 4. AC-1 TO BE INSTALLED WITH AN ECONOMIZER WITH MOTORIZED DAMPERS ON THE INLET AND THE OUTLET PER WSEC SECTION C403.2.4.4 a Md.& liki on = 2017, ► MC' FILE COPY Pert No. MI5. O% Plan review approval is subject to errors and orn;ssions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: REVISIONS No changes shall be made to the scope of work withel.a prior approval of Ti ik '' a E'ti.'.d tr f7Yvision NOTE. r,;i lI 1;'—, ran submit},-' anional p:an 0_3- 6- l (n City of l u Si+'4iia BUILDING DIVISION ISE A7 TE REQUIRED FOR: ❑ Mechanical Electrical .0Plumbing 'Gas Piping Hof Tukwila DRAWING SYMBOLS NORTH ARROW SECTION IDENTIFICATION SHEET IDENTIFICATION COLUMN GRID SYMBOLS GENERAL MECHANICAL NOTES NUMBER IDENTIFICATION FLAG MECHANICAL NOTES NUMBER IDENTIFICATION MECHANICAL LEGEND SYMBOL DESCRIPTION INFORMATIDrU T gruND NEW WORK (HEAVY UNE) gragi INGITATEDQUIPMENT ITEM TO BI SELECIIVELNYTDEMEar POINT OF NEW CONNECTION WICAt'SFPIATIZVASIGNAIMN ROOM/ZONE THERMOSTAT 21918TFIGURE SIDE NRESHOVP ' U + FLEXIBLE CONNECTION T VOLUME DAMPER ? 45' TAKE -OFF t rwwv ECRD TERMINALS: FUN TYPt - RL - RS C 45' iggANGULAR TAKE -OFF WI1N FLEXIBLE DUCT MOTORIZED DAMPER COMBINATION SMOKE/FIRE DAMPER FIRE DAMPER R©ADIIA110N DAMPPR E OR GRILLE OILING DIFFUSER, TYPE 1. BA0R< TO 350 CFM RETURN GRILLE, TYPE 1 itkil EN�TO 350 CFM TRANSFER GRILL, TYPE 1 24x12 NECK BALANCE TO 350 CFM TYPICAL OF 2 CEILING DIFFUSER CEILING RETURN GRILLE CEILING EXHAUST GRILLE REFRIGERANT UQUID LINE REFRIGERANT SUCTION LINE CONDENSAE EWES FO SHEET INDEX MO.1 HVAC SCHEDULES M1.0 HVAC FLOOR PLAN M2.0 HVAC ROOF PLAN/ELE EVISION N CODE COMPLIANCE APPROVED DEr. 09 7015 110 g-V-- City of Tukwila BIDING DIVISION RECEIVED CITY OF TUKWILA SET DATE: 10-07-15 NOV 19 2015 PERMIT CENTER 0 LO r r r 0 0= } F- -1111111= 0 I0 1 0 d r s H HVAC SCHEDULES O 0 m E z CI 8 LTA ro QO> T Z r 1 12) fYd'-%) SHEET NUMBER M0.1 CONTRACTORS LICENSE CFMHEHC969CD REVISION WOMEN'S RESTR0OM, OF HOSUE • EXISTING :.4" UP. TO ROC" MEWS RESTROOM 107 K. . 36X24 36X24 ol �� l4Li!]1 aii \ _JAW K IN WALK IN ZER• ICE.=_vir_ laCti E[ IJ 12"o GALVANIZED STEEL FROM.. PIZZA OVEN .. ANSITIONS OV IN CEIL(IG` EN UPTO 'FAWON ROO TYPE 2 HOOD OVER PIZZA DECK OVEN. OOK INE HVAC FLOOR PLAN SCALE:4"=1'0" Km `�r _ ISTING 4 TO ROOFTOP um- DROPS • SET DATE: 10-08-15 r O W) CO a Lu mz } m 2 c7 • m 4 z u zYo co 0 0 0 0 U CC 00 T CC 00 W W co D Z T W 0) 0 =< F-� D w co U) O • N N D cc Q. r F-- 0 HVAC FLOOR PLAN REVIEWED FOR CODE COMPLIANCE APPROVED DEC 092015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 19 2015 PERMIT CENTER SHEET NUMBER 0 0 co ▪ E W �O8 z� 6 LL1rnco 0ar"J Win` r _ N M1 .0 �dFdin a2a' E Lg,5 a .EC) CFMHEHC969CD CONTRACTORS LICENSE SOUTHCENTER PARKWAY EXISTING PARKING LOT EXISTING PARKING LOT EXISTING COMMERCIAL BUILDING EXISTING PARKING LOT EXISTING PARKING LOT PIZZA STUDIO TENANT SPACE SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Set loctrical ErDiumbing Gistras Piping City of Tukwila BUILDING DIVISION REMSIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 1 EXISTING PARKING LOT FILE COPY Permit No. MIS" 0U3) Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Co and conditions is acknowledged: By: <5t4ti Date: City of Tukwila BUILDING DIVISION MINKLER BLVD SITE PLAN SCALE: N.T.S. RECEIVED crrY jr-cTUKWILA OCT 0 9 2015 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED NOV 16 2015 A-T w City of Tukwila BUILDING DIVISION 15 SET DATE: 10-08-15 z 0 in cc m 0 0 8 m °z . 2 ° m 2 Z W Y Q p] ¢ t- WWs Q O 0 Q CC CO Q T CC W W00 w W 0 =Q � Do ��< N • NOD u_ z a. W 0 SHEET NUMBER Al .0 CONTRACTOR'S LICENSE CFM H E HC969CD ABBREVIATIONS AC AD AFC AFF AHU AL BDD BFC BHP BI BOD BTU BTUH CFM COO CW CRD AIR CONDITIONING ACCESS DOOR ABOVE FINISHED CEILING ABOVE FINISHED FLOOR AIR HANDUNG UNIT ALUMINIUM BACK DRAFT DAMPER BELOW FINISHED CEILING BRAKE HORSE POWER BACKWARD INCLINED BOTTOM OF DUCT BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR CUBIC FEET PER MINUTE CLEAN OUT CONSTANT VOLUME COLD WATER CEILING RADIATION DAMPER DIA DIAMETER DIM DIMENSION DMPR DAMPER DN DOWN DP DIFFERENTIAL PRESSURE DWG DRAWING EX EXISTING EAT ENTERING AIR TEMPERATURE EF EXHAUST FAN EFF EFFICIENT, EFFICIENCY EG EXHAUST GRILLE ELEC ELECTRICAL FG FLOOR GRILL FD FIRE DAMPER F FURNACE FPM FEET PER MINUTE FSK FOIL SKRIM KRAFT LINER (SPUNSTRAND) FT FEET, FOOT G GAS GR GRILLE HP HORSE POWER HR HOUR HTG HEATING HVAC HEATING, VENTIALTION AND AIR CONDTIONING HW HOT WATER ID IN INFO INSUL INSIDE DIMENSION INCH, INCHES INFORMATION INSULATE, INSULATION JAN JANITOR KW KILOWATT KWH KILOWATT HOUR LAT LEAVING AIR TEMPERATURE LF LINEAL FEET LVG LEAVING MA MIXED AIR MBH THOUSAND BRITISH THERMAL UNITS PER HOUR MIXED AIR TEMPERATURE MAXIMUM MECHANICAL MANUFACTURER MEDIUM MINIMUM, MINUTE MISCELLANEOUS NORTH NOT APPLICABLE NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE OUTSIDE DIMENSION OPPOSITE OUTLET VELOCITY MAT MAX MECH MFG MED MIN MISC NA NTS OSA OAT OD OPP OV PD PERF PF PH QTY RA REQD RET RGM PRESSURE DROP PERFORATED PRE FILTER PHASE QUANTITY RETURN AIR REQUIRED RETURN REVOLUTIONS PER MINUTE RETURN GRILLE MECHANICAL SPECIFICATION GENERAL SCOPE THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL MECHANICAL SYSTEM. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO COMPLETE THE MECHANICAL WORK. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW OFFSETS WHICH MAY BE REQUIRED. SITE EXAMINATION THE MECHANICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, DUCTWORK, AND PIPING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE MECHANICAL WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ARL, ASME, ASTM, UL, NEMA, ANSO, SMACNA, ASHRAE, NFPA, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFUCT BETWEEN THE DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE MECHANICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO THE OWNER. PERMITS AND FEES THE MECHANICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE MECHANICAL WORK. WARRANTY THE MECHANICAL CONTRACTOR SHALL UNCONDITIONIALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY OWNER, AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND SHALL RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. DUCTWORK AND ACCESSORIES SHEET METAL DUCTWORK ALL DUCTWORK TO BE RIGID SHEET METAL CONSTRUCTED FROM GALVANIZED SHEET STEEL IN ACCORDANCE WITH SMACNA LOW VELOCITY DUCT CONSTRUCTION STANDARDS. ALL EXPOSED DUCTWORK TO BE ROUND, SPIRAL, LOCK SEAM TYPE. ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AIR TIGHT (8% LEAKAGE) AND NOISELESS (NO OBJECTIONABLE NOISE) SYSTEMS CAPABLE OF PERFORMING EACH INDICATED SERVICE. FURNISH ALL DAMPERS, TRANSITIONS, CONNECTIONS TO AIR TERMINALS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE OPERATING SYSTEM. NO VARIATION OF DUCT CONFIGURATION OR SIZES WILL BE PERMITTED EXCEPT BY PERMISSION FROM THE ENGINEER. PROVIDE LEAK TEST IF REQUIRED BY DPD DUCT SEALANT SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS WITH A NON -HARDENING, NON -MIGRATING MASTIC OR LIQUID ELASTIC SEALANT OF A TYPE RECOMMENDED BY THE MANUFACTURER FOR SEAUNG JOINTS AND SEAMS IN SHEET METAL DUCTWORK. COVER ALL FIELD JOINTS, JOINTS AROUND SPIN -IN FITTINGS, AND FASTENING SCREWS WITH MASTIC. SUPPORTS: PROVIDE HOT -DIPPED GALVANIZED STEEL FASTENERS, ANCHORS, RODS, STRAPS, TRIM, AND ANGLES FOR SUPPORT OF DUCTWORK. PROVIDE SEISMIC BRACING FOR HEAT PUMPS IF REQUIRED BY DPD DAMPERS PROVIDE OPPOSED -BLADE, MULTI -LEAF VOLUME CONTROL DAMPERS WHERE INDICATED ON DRAWINGS AND AT POINTS ON LOW PRESSURE SUPPLY, RETURN, AND EXHAUST DUCTS WHERE BRANCHES ARE TAKEN FROM LARGER DUCTS. PROVIED UL LISTED FIRE DAMPERS WHERE REQUIRED AND IN ACCORDANCE WITH NFPA AND LOCAL CODES. PROVIDE CONVEINIENTLY LOCATED ACCESS DOORS OF AMPLE SIZE AND QUANTITY FOR SERVICING THE DAMPERS. PROVIDE DAMPERS AT ALL BRANCH LINES AND TAKE -OFFS. GRILLES, REGISTERS & DIFFUSERS GRILLES, REGISTERS, AND DIFFUSERS SHALL BE INSTALED AS INDICATED ON THE DRAWINGS AND SCHEDULES. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS ITEMS NECESSARY FOR A COMPLETE AND PROPER INSTALLATION IN THE TYPE OF CEILING AND WALLS USED IN THIS PROJECT. THERMAL INSULATION PROVIDE EXTERNAL THERMAL INSULATION WITH AN INTEGRAL VAPOR BARRIER FACING OF SUFFICIENT THICKNESS TO MEET LOCAL ENERGY CODE REQUIREMENTS. PROVIDE INSULATION ON EXHAUST AND OUTSIDE AIR DUCTS, AND ON CONCEALED PORTIONS OF SUPPLY AND RETURN AIR DUCTS. DO NOT INSULATE EXPOSED DUCTWORK AND PORTIONS OF DUCTWORK THAT ARE INTERNALLY LINED. THERMAL INSULATION TO COMPLY WITH AN NFPA FLAME SPREAD OF 25 OR LESS, AND SMOKE DEVELOPED NO GREATER THAN 50. ACCOUSTICAL DUCT LINER: UNLESS OTHERWISE INDICATED ON THE PLANS, PROVIDE 1" GLASS FIBER ACCOUSTICAL DUCT LINER ON SUPPLY AND RETURN DUCTWORK WITHIN 10 FEET OF THE DISCHARGE AND INTAKE OF AIR HANDUNG UNITS. INCREASE DUCT SIZE INDICATED ON PLANS 2" IN EACH DIMENSION TO ACCOMODATE LINER. PACKAGED ROOFTOP AC UNIT SCHEDULE MARK MAKE MODEL CFM SP. COOLING HEATING ELECTRICAL WEIGHT ECONOMIZER SOUND TOTAL SENS SEER INPUT OUTPUT AFUE% DATA FUSE M.C.A. AC-1 CARRIER 48KCDA05A2A5-OAOA0 1600 .50" 48.73 37.51 14.00 SEER 72.0 56.0 80.0 208-3-60 30 24 719 LBS. YES 81.0 dBA FAN SCHEDULE SYMBOL MAKE & MODEL SERVES CFM SP RPM MOTOR ELECT. TYPE WEIGHT BDD NOTES EF-1 PANASONIC FV08Q53 WOMEN'S RESTROOM 108 80 0.5" 779 120-1-60 CEILING 12 LBS YES VENT TO ROOFCAP 21.2 WATTS EF-2 PANASONIC FV08Q53 MEN'S RESTROOM 107 80 0.5" 779 21.2 WATTS 120-1-60 CEILING 12 LBS YES VENT TO ROOFCAP EF-3 ILG CRBA 10 PIZZA DECK OVEN 623 0.5" 1503 1/4 HP 115-1-60 ROOFTOP 115 LBS NO SERVES PIZZA OVEN HVAC NOTES: 1. EF-3 IS TO BE INTERLOCKED WITH AC-1 FOR MAKE UP AIR (600 CFM PROVIDED FOR MAKE UP AIR) 2. TYPE 2 HOOD CONSTRUCTION IS 24 GAUGE STAINLESS STEEL AND DUCTWORK CONSTRUCTION IS 26 GAUGE STAINLESS STEEL 3. EF-3 MUST TERMINATE A MIN. OF 30" ABOVE ROOF 4. AC-1 TO BE INSTALLED WITH AN ECONOMIZER WITH MOTORIZED DAMPERS ON THE INLET AND THE OUTLET PER WSEC SECTION C403.2.4.4 1 CIO C11 Of 1 '...11,W 00 0 9 2015 PEI:1M1T CENTER DRAWING SYMBOLS NORTH ARROW SECTION IDENTIFICATION SHEET IDENTIFICATION COLUMN GRID SYMBOLS GENERAL MECHANICAL NOTES NUMBER IDENTIFICATION FLAG MECHANICAL NOTES NUMBER IDENTIFICATION MECHANICAL LEGEND SYMBOL 0 DESCRIPTION FRRI TiON LIGHT OMROUND NEW WORK (HEAVY UNE) OR DENIM' TNT EDQUIPMENT ITEM TO BE SELECTIVELY DEMOLISHK POINT OF NEW CONNECTION 1EXHAt�S FUTAMEEV5S/GNA110N ROOM/ZONE THERMOSTAT ._-12X8 ���� ((�� TT EE gip gg oo 2NDTFIGUREFI SIDE NOT SHOWN I INIVVvy FLEXIBLE CONNECTION VOLUME DAMPER 45* TAKE -OFF 9400' RECCTTAANGULAR TAKE -OFF WITH FLEXIBLE DUCT MOTORIZED DAMPER COMBINATION SMOKE/FIRE DAMPER FIRE DAMPER 0111CRD RBADIA111ON DA EE �� GRILLE TERMINALS: TG-1 TYPT RL RS C CgIUNG DIFFUSER, TYPE 1 BALANCE TO 350 CFM 2REE�T�U2RNNEGRILLE, TYPE 1 BALANCE CTO 350 CFM TRANSFER GRILL, TYPE 1 24x12 NECK BALANCE TO 350 CFM TYPICAL OF 2 CEILING DIFFUSER 44— CEIUNG RETURN GRILLE CEIUNG EXHAUST GRILLE REFRIGERANT LIQUID LINE REFRIGERANT SUCTION LINE CONDENSATE PIPING SHEET INDEX MO.1 HVAC SCHEDULES M1.0 HVAC FLOOR PLAN M2.0 HVAC ROOF PLAN/ELEVATION REVIEWED FOR CODE COMPLIANCE NOV 16 2015 ity of Tukwila ILDING D VISI SET DATE: 10-07-15 136 8 gR v 3 c E o CFMHEHC969CD REVISION w 0 O z I0 C m cr T rr- W vJ O0 I— (j � J Q 0 -§ N i° ■ 0 fl ■ w 1-- HVAC SCHEDULES 0 z o LLU U °6 z LLI 0 0 E mm w C3 8 zO co U cif Q Q L TZ*- N. r N ,—Yd� SHEET NUMBER MO.1 CONTRACTORS LICENSE 1 z 0 LL EXISTING.:.4"0 UP. TO RO . MEN'S ESTROOM OF HOSUE ,•• ;:; 36X24 7 K IN ZER J WALK IN 36X24 36X18 PIZZA.6�' �-ANSITIONS 0 IN CEILING j C�. EN UP' TO FA ON ROOF' TYPE 2 HOOD OVER , PIZZA DECK OVEN HVAC FLOOR PLAN SCALE:4"=1'0" ROOFTOP UNIT DROPS — DINT 'JG REVIEWED FOR CODE COMPLIANCE APPROVED NOV 1 6 2015 City of Tukwila BUILDING DIVISIC),` ' RECEIVED CITY OF TUKWILA OCT 0 9 2015 PERMIT CENTER SET DATE: 10-08-15 ahlkab gal . CUZp >M W 0 O z rNi CC 00 CC W I- Ca T W 0 0 Cn co Q O NL17 • NOD cr 0 O..T1— LL J HVAC FLOOR PLAN U z 0 z wo • zc o c,i z ' cv co E (1) SHEET NUMBER M1 .0 CONTRACTORS LICENSE CFMHEHO969CD REVISION TOP OF PARAPET AC 0 — 4' ® r 1 7' f..._ II I I i i 2'-6 " — 25' 18' ACTUAL ROOFLINE GROUND LEVEL ECONOMIZER FRESH AIR INTAKE SIDE MUST BE 10' MIN. FROM ALL EXHAUST OUTLETS 10' NORTH ELEVATION ADJACENT TENANT SPACE BELOW OUTLINE OF TENANT SPACE BELOW EXHAUST FAN FOR TYPE 2 KITCHEN HOOD OVER PIZZA OVEN MUST DISCHARGE A MIN. OF 30" ABOVE ROOF 12"0 DUCT UP FROM PIZZA OVEN ADJACENT TENANT SPACE BELOW HVAC ROOF PLAN SCALE:"=1'0" OUTLINE OF TENANT SPACE BELOW EXISTING AC UNIT &REVIEWED FOPz \-- CODE COMPLIANCE APPROVED NOV 16 2015 City Of Tukwila BUILDING DIVISION RECEIVED CIIV OF TUKWILA OCT 0 9 2015 PERMIT CENTER SET DATE: 10-08-15 ID W 0 0 z JOB NUMBER d z m m o z w 0 0 CC 00 Q d" 12- T CC W W 000 z T W ori Do Qo N ■ NOD o 1 T LL ■ w -J 1— ROOF PLAN/ELEVATION U z 0 z 0 0 • m E W (Y') U zo• WO co ro Q Q .c O p r U gr� N E i 2 rYdN'� SHEET NUMBER M2.0 CONTRACTORS LICENSE CFMHEHC969CD