HomeMy WebLinkAboutPermit M15-0135 - ROSS STORE - ROOFTOP UNIT REPLACEMENTSROSS STORE 17672 SOUTHCENTER PKWY M15-0135 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 3523049005 17672 SOUTHCENTER PKWY Project Name: ROSS STORE Permit Number: M15-0135 Issue Date: 10/29/2015 Permit Expires On: 4/26/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KIR TUKWILA 050 LLC/KIMCO 3333 NEW HYDE PARK STE 100 PROPERTY TAX DEPARTMENT, NEW HYDE PARK, OR, 11042 JIM DRYDEN 1365 N FRONT ST, WOODBURN, OR, 97071 WOLFER'S INC 1365 N FRONT ST, WOODBURN, OR, 97071 WOLFEI*916P6 Phone: (503) 981-4511 Phone: Expiration Date: 10/26/2017 DESCRIPTION OF WORK: REPLACE (6) ROOFTOP UNITS. REPLACEMENT UNITS ARE LIKE FOR LIKE Valuation of Work: $22,866.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $494.14 Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE,TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: Date: 10—A � I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permiyand agree to tj conns attached to this permit. Signature: Print Name: Date: )6 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 2: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 3: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 4: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 5: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 6: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 7: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 8: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 9: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 14: Readily accessible access to roof mounted equipment is required. 15: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 16: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 17: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 18: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 19: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 20: ***MECHANICAL PERMIT CONDITIONS*** 21: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 22: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 0703 1800 0705 0701 0702 FIRE FINAL MECH EQUIP EFF MECHANICAL FINAL REFRIGERATION EQUIP ROUGH -IN MECHANICAL SMOKE DETECTOR TEST a separate permit the job site at the issued by the City of Tukwila time of inspection. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. V( (J Q E3S Project No. Date Application Accepted: 1. 0 Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 17672 South Center Pkwy Tenant Name: Ross Stores, Inc PROPERTY OWNER Name: ej1� 1/oa t / u p! /,„ ,n r l7e/�l`Vc ""l:74 Fa (v�Lctlyel Address: /5� S fuel / fl // City: / /7euu State: q Zip: Q8 CONTACT PERSON — person receiving all project communication Name: Jim Dryden Address: 1365 N Front St City: Woodburn State: Or Zip: 97071 Phone: (503) 981-4511 Fax: (503) 981-0801 Email: jim@wolfersheating.com King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes m ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Wolfer's Home Services Address: 1365 N Front Street City: Woodburn State: OR Zip: 97071 Phone: (503) 981-4511 Fax: (503) 981-0801 Contr Reg No.: 600 y76 0-77 Exp Date: 5 3), /0 Tukwila Business License No.: Valuation of project (contractor's bid price): $ 22,866 Describe the scope of work in detail: Replacement of 6 rooftop unit. replacement unit are like for like. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement VI Fuel Type: Electric Gas ❑ Other: H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 4 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit I^ <10,000 cfm (J Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: ✓NER OR AUT .J IZED AGENT: Print Name: J;An Mailing Address: ! 310 5.(�� cf'C'1 Date: [- 3©- t s- Day Telephone: S~O 3 — 7 1 d" (3 3 1 t,vao(PJ City H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh U�- State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY PermitTRAK I PAID $494.14 M15-0135 Address: 17672 SOUTHCENTER PKWY Apn: 3523049005 $494.14 MECHANICAL $475.13 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $347.60 PLAN CHECK FEE R000.322.102.00.00 0.00 $95.03 TECHNOLOGY FEE $19.01 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6411 R000.322.900.04.00 0.00 $19.01 $494.14 Date Paid: Tuesday, October 13, 2015 Paid By: KAREN CHRISTIN Pay Method: CREDIT CARD 413150 Printed: Tuesday, October 13, 2015 12:06 PM 1 of 1 CL. �1 SYSTEMS INSPECTION RECORD Retain a copy with permit /5-6 f3.* INSPECTION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro ect: �t 5.S V /�1'� T pe of Ins ec ion: Y i2 PA ; 4 Address: I 47 7 .S�fAc ' • - e ailed: ` - Special Instructions: Date Wante '' // a m p.m. Requester: Phone No: pproved per applicable codes. I Corrections required prior to approval. COMMENTS: Inspector: Date: t? REINSPECTION FEE REQUIRED. Prior to next inspectigh. fee,v(tust be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD 1 Retain a copy with permit l /1'Jl .3,11- PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project- Si S/ C2-5 C ,rc Type of Inspection: /YJc - 4 J.C;ixav Add/� E-72 �S4 rf 1A Special Instructions: . (p.m. Date Wat ed: Requester: Phone No: yApproved per applicable codes. COMMENT Corrections required prior to approval. G/ A/re-,17 nspector: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit l INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project / C6 S 5- tc` Type of Inspection: �4. ...1 /-.. Address: /7 ,72 50 d /L4--#4,-Ra Da Ca ed: 12A Special Instructions: Date Wanted , P Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Q�. 1#09--cPci ° / / v' _ C C 1 7.41/ Inspector: --110ate: REINSPECTION FEE REQUIRED. Prior to next inspection fee must bel paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ir . REVISIONS No changes sha[� ,;-- of work withort prior e to the scope _ ru , i!a E, _ .ciiric c U: ova! of C... TE-,. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 21 2015 City of Tukwila BUILDING DIVISION ,..� a4.•s•,E,. ,EQUiRT J FOR: 0 Mechanical Electrical ,aPtumbing ,' Gas Piping FILE COPY Permit No. Mt0 Ni/216 Plan review approval is subject to errors and omissions. Approval rsf construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fief + C s py : d o d"s'an - i =ckr,3wledged: By: Date: City UILDii :::... ,..-; i' :S1O M15O13S RECEIVED CITY OF TUKWILA OCT 1.32015 PERMIT CENTER e. The Roof Reinforcer STRUCTURAL ANALYSIS REPORT for HVAC REPLACEMENT 17672 Southcenter Pkwy, Tukwila, WA 98188 Morris Ave S Shattuck Ave S to0.e eves L) Lind Ave SW in t N N y♦ `p L A N 3 Oakesdaie Ave SW sv IKEA Seattle a Lind Ave SW t, ;N Powell Ave SW Lrr. 3n N >a c � J 3E F w S2r= SI MS pet -4alg.4,0 4 ■ y N S3rd Ave 5 51slAve S 51atAve S y 6.1 Sa4y!°!S S 8 = S, n traitor, µd £ y r 0 01 S 8 = r N 45Ih Ave S N 1 e N to coyr co \\t8I � S any 9,94 in t g in.- 4 2nd Ave y Pu /,,J 8 Pa5 848th Ave pun, late S an i 8"'V �l��a`� t N 9 le t N 'U N 'G b ▪ con LL y .j N co8 N 41 in 0 co 34th Ave S :n 34th Ave S To 33rd Ave S OS a ¢ 4 32nd Ave S ■ cii co ✓ N 13 'c• oe ▪ < i 2 b y pcp - - O N (n '- (n iy IIi fL p I-,, 'emssacdx3lrode' s,., n 2 = L V if 1:' 1 N Talbot Rd S 8'3th Ave S S any pull a o op S ao'V 094 S 4^VICILE H Sonypuu - 28th . yJed JaAopuy Andover Park W D CL Andover Park W a 0 _.. • N J a' 2.... fi w a N 5 -8m vt t0 o g°a - 0 60 0 2 Q C. tv0i = r et au. N n A @ U 1 Z • 0 H L11 • O , ter PkwY n Fabric and Craft 6 R"Us/Babies"R"Us (S 6 Cost Plus World Market Andover Park W Applebee•s Oa David's B soot cer\ J M -let (17 0 Sansaco Home Main (805) 648-8949 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 1 2015 City of Tukwila ;BUILDING DIVISION a_ RECEIVED CITY OF TUK/i! , OCT 1.3 2015 PERMIT CENTER 2 SITE LOCATION 434 E. Main Street B, Ventura, CA 93001 r~ oZce /1401 STRUCTURAL ANALYSIS REPORT for HVAC REPLACEMENT The Roof Reinforcer l/7 0 CC 17672 Southcenter Pkwy, Tukwila, WA 98188 J cc w 71. 00 00 71. kra 00 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 1 2015 City of Tukwila BUILDING D SION CITY OF TUKWILA OCT 1 3 2015 ERMIT CENTER V CC Q � � w © tom 0 x h 434 E. Main Street B, Ventura, CA 93001 z a p. o 70 IV 0 N on Z m r m z 0 r Cn m 70 cn 0 cn c0 m 0) 1 0 CURBS PLUS l ?I o TRANSITION -CURB SYSTEM 1200 Carlene Rd. Confidential and propriety Information of Curbs Plus, Inc. unauthorized use, disclosure, or reproduction Is expressly prohibited. Rossville, GA 30741 TAG PLATE:LX8TR225 / LX111 TR225 Phone:(706) 858-1188 / Fax: (706) 866-2339 website: www.curbs-plus.com APPROXIMATE WEIGHT:420 LBS. (/ 0, SHELL:14 GA Drawing Date: 3-29-05 LREV: 001 PANS:18 GA CHANNELS:14 GA \\\ .\\R BURGLE \ N - 71"E 101 1/2" 0.D. 981/2" I.D. co co co CT1 .,'- 3" -,' f 14" = O h. z CLOSURES: 14 GA Approved By: 1 diX (fli 1 o REVtEWED FOR CODE COMPLIANCE APPROVED OCT 21 2015 City of Tukwila BUILDING DIVISION S/A AND R/A 17) Z _ TAG: RTU-4,5— [ROLLS OF GASKET:2 1 SACA/SACC/S FCA/S FCEK15/ 17 OLD UNIT:TRANE w L/T/K-SERIES/LGH-LCH j56-360 NEW UNIT:LENNOX QTY.: 2 DRAWN B?.: SLW imam. 518" i F855/8" 82 I.D.D 1" 1" 27 5/8" 37"6" f- m R M 0 33 E_ O { .1 n — If 1. -.1 in 0" C < zill j x m C -v.,- 3" 19" -' 231/2" / 13114" �141/2" 21/4" 3 /8" r Xi a ..+ 7 ,V2" A 2012 Washington State Energy Code Compliance Forms for Commercial, Group RI, and > 3 story R2 and R3 Mechanical Summary MECH-SUM 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Info Project Address: 17672 Southcenter Pkwy Date 1/1/2015 Tukwila, Washington 98188 For Building Dept. Use 1 - This address line will copy onto other forms Applicant Name: Wolfer's Inc REVIEWED Applicant Address: 1365 N. Front St Woodburn, Or 97071 FOR CODE COMPLIANCE Applicant Phone: 503-220-1901 Project Description Briefly describe mechanical systems in the text box provided New Building ❑Building Addition ✓ Tenant Improvement ❑System R€rofit ArPROVED Li No System Changes OCT 2 1 2015 ❑Total Bldg Performance Total Bldg Performance compliance includes all mandatory provisions per C401.2 Option 2. MECH-SUM, MECH-CHK, and C407 Energy Jai s°t ` City of Tukwila BUILDING DIVISION Analysis Summary forms required. Mechanical Systems Summary 1 Equip ID;; Type of System (Note 1) Space(s) Served Compliance - Path Heating . and Cooling °Fan Flow Controls „ Air:. Economizer' (Note 2) - Ventilation (Note 3) Energy Recovery RTU-1 roof top pkg H/P unit Retail Heating and cooling Constant volume (CV) Yes Provided but not required Not Required RTU-2 roof top pkg H/P unit - - Retail .Heating -and . cooling -Constant . volume (CV) .Yes Minimum per WAC Not Required RTU-4 roof top pkg H/P unit Retail Heating and cooling Constant volume (CV) Yes Minimum per WAC Not Required RTU-5 roof top pkg H/P unit Retail Heating and cooling Constant volume (CV) Yes Minimum per WAC Not Required RTU-6 roof top pkg H/P unit Retail Heating and cooling Constant volume (CV) Yes Minimum per WAC Not Required RTU-7 roof top pkg H/P unit Office Heating and cooling Constant volume (CV) Yes Minimum per WAC Not Required Note 1- Provide basic description of system type, for example: unitary rooftop air handler, built-up central air handler, single -packaged, split system or packaged terminal air conditioner or heat pump; unit heater, warm -air fumace, electric resistance heater, 4-p pe fan coil, VRF system, energy recovery air handler, make-up air system, ground or water -source heat pump, etc. Note 2 - If taking an exception to air economizer, select exception taken from drop down menu and complete MECH-ECONO form. Summary definitions of each exception are listed in MECH-ECONO. Note 3 - If ventilation "Not applicable" is selected, provide explanation in Project Description box above. HVAC Hydronic Systems ❑ Hydronic chilled water ❑ Water -loop heat pump ❑ Hydronic heating ❑ Geothermal ✓ No hydronic systems Service Water Heating Systems Equipment Type (s) ❑ Hot water heating tank(s) ❑ Instantaneous Dedicated boiler ❑ Heat exchange from space heat boiler or central hotwater/steam CITY Distribution Type (s) ❑ Circulation System ❑ On -demand ✓ OCT No service water systems RECEIVED OF TUKWILA 1:3 7015 Mechanical Schedules Indicate however, ✓ Mechanical Plans ❑ MECH-EQ Form location of equipment compliance information. If provided on plans then MECH-IrTnCcER include on plans all applicable compliance information listed in MECH-EQ tables. NIS-Ol35 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Design Load Calculations ❑ Load calculation summary ❑✓ MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC form is not required. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary, pg. 2 MECH-SUM Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 2012 Washington State Energy Code Compliance Forms for Commercial Fan Power air distribution systems that provide heating and/or cooling -SUM form. the total fan motor nameplate hp of all fans in HVAC system exceeds 5hp. MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. and MECH-FANSYS-DOC for requirements and exceptions. Project includes HVAC If yes, provide a MECH-FANSYS ❑ For one or more systems, If yes, provide a seperate Refer to Section C403.2.10 Commissioning Exception Summary Describe means of eligibilty for commissioning exception (capacity, etc) for all systems noted as taking exception in Mechanical Systems Summary table. Refer to Section C408.2 and C408.4 for exceptions. J Commissioning will be provided for all heating Figure completion. applicable systems Commissioning Exceptions: ❑ Mechanical system(s) ❑ Service water system(s) For systems requiring commissioning, code official upon project .C408.1.2.1 Commissioning Compliance Checklist shall be submitted to the Low Energy and Semi -Heated Spaces (Note 6 and 7) Space Type ; Location in Plan(s) , " " " "- • Space(s) Served ° • ' Area Served, square feet Heating Capacity; Btu/h ,(Note-4) . ;Cooling ' Capacity, Btu/h .;(Note"5) " Peak Space 'Conditioning' '.• Capacity, •, Btu/h-sf' , Compliance `'Check • Notes Note 4 - Provide total installed heating ou put capacity of systems serving Low Energy or Semi -Heated space(s) in btuh. Note 5 - Provide total installed cooling capacity of system serving Low Energy space(s) in Btu/h. Not allowed for semi -heated spaces. Enter 0 if no cooling. Note 6 - Refer to Section C101.5.2 Low Energy Building. Intalled peak space conditioning capacity, heating or cooling, may not exceed 3.4 Btu/h-sf. Note 7 - Refer to Section C402.1.4 and Semi -Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 btuh/sf. Only systems electric resistance heating and no cooling are eligible for the wall insulation exception under semi -heated. without 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Permit Plans Checklist - Page 1 of 4 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 17672 Southcenter Pkwy Date 1/1/2015 Project -Address --•- • - The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicableable (yes,n Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes GENERAL PROVISIONS Equipment Sizing & Performance C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 C403.2.2 Equipment and system sizing Output capacities of heating and cooling equipment and systems do not exceed the next larger available equipment size above the calculated loads; note exceptions taken C403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical ventilation is capable of being reduced to minimum requirement per IMC C403.2.3 & C403.2.3.2 & C403.2.12.1 Equipment minimum efficiency Provide equipment schedules or complete MECH-SUM tables with type, capacity, efficiency, test standard (or other efficiency source) for all mechanical equipment C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, and efficiency for all motors; note exceptions taken C403.2.10.1 Fan power limitation For all applicable systems > 5hp, provide system total nameplate hp in MECH-FANSYS-SUM form C403.2.10.1 Fan power limitation For all applicable fan systems > 5hp, verify fan system motor hp or bhp complies with fan power limits per Table C403.2.10.1(1), provide MECH-FANSYS form for each system C403.2.10.2 Motor nameplate hp Indicate fan motors specified are the smallest available motor hp size greater than fan bhp, note exceptions taken C403.2.10.3 & C403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. C403.2.3 Maximum air cooled chiller capacity Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit C403.2.3.1 Non-standard water-cooled chillers Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non-standard operational conditions C403.2.12.1.2 Centrifugal fan cooling towers Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan open circuit cooling towers C403.2.3 Forced air furnace and unit heaters Indicate intermittent ignition or !ID, flue/draft damper & jacket loss C403.2.3.3 Packaged electric heating/cooling equipment Verify all packaged electric equipment that provides > 20,000 Btu/h cooling capacity and heating is a heat pump, note in equipment schedule C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer) HVAC System Controls & Criteria C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including perimeter systems C403.2.4.1.1 Heat pump supplementary heat Indicate staged heating (compression/supplemental) and outdoor lock -out temperature is set to 40°F or less C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & cooling C403.2.4.3 Automatic setback and shutdown Indicate zone t-stat controls with required automatic setback & manual override C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load conditions C402.4.5.2 & C403.2.4.4 OSA, exhaust, and relief air dampers Indicate location of outdoor air supply intake, and exhaust and relief outlet dampers; verify Class 1 leakage rating and control type (motorized or gravity); note exceptions taken C402.4.5.2 Retum air dampers Indicate location of retum air dampers that are integral to economizer operation; verify motorized control and Class 1 leakage rating; note exception taken C402.4.5.1 Stairway and shaft vents Indicate location of stairway and shaft vents, verify Class 1 leakage rated motorized dampers and method of activation C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions C403.2.4.6 Combustion heating equipment Indicate modulating or staged control C403.2.4.7 Group R1 hotel/motel systems Indicate method for guest room temperature automatic setback (heating) & set-up (cooling), confirm adjustment of at least 5°F minimum. C403.2.4.8 / 9 Group R2/R3 dwelling and sleeping unit systems Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback periods and 10°F deadband; note exceptions taken C403.2.5.1 Demand controlled ventilation Indicate high -occupancy spaces and systems requiring DCV C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or alternate means provided to automatically reduce OSA when partially occupied 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Permit Plans Checklist - Page 2 of 4 MECH-CHK Washington State Energy Code Compliance Forms for Commer & R3 3 stories and all R1 Revised Aug 2015 Project Address -- 1767.2SouthcenterPkwy Date---—.1/1-/2015-- The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued C403.2.5.3 Enclosed loading dock/parking garage ventilation Indicate enclosed loading dock and enclosed parking garage ventilation system activation and control method C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning method C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery, method & efficiency; or alternative method taken (VAV, semi -conditioned makeup, or GERM calculation) C403.2.6.1 Energy recovery (ER) - ventilation systems Indicate ventilation systems requiring ER, method & efficiency; note exceptions C403.2.6.2 Energy recovery (ER) condensate systems Indicate on -site steam heating systems requiring energy recovery C403.2.6.3 Energy recovery (ER) cooler/freezer condensers Indicate remote refrig. condensers requiring ER and use of captured energy C403.4.6 - Energy recovery (ER) - condenser systems Indicate condenser systems requiring ER to pre -heat service water; indicate ER effectiveness; note exceptions taken C403.2.12 Variable flow control - fans/pumps Indicate fan and pump motors 2 7.5 hp and the method of variable flow control (VSD or equivalent controls) C403.2.12.1 Variable flow control - heat rejection equipment Indicate heat rejection equipment and cooling tower fans requiring variable flow control and method C403.2.12.2 Large volume fan systems Indicate single zone fan systems requiring airflow reduction capability in response to reduced cooling or heating demand in a zone, or adjacent zones without separating walls, with > 10,000 CFM supply air; note exceptions taken C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for air conditioning systems > 110,000 Btu/h serving single zones C403.2 4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for trending and demand response setpoint adjustment - Ducting Systems C403.2.7.1 &Duct C403.2.7.3 construction Indicate all ductwork constructed and sealed per IMC, C402.4 leakage requirements and IBC vapor retarder requirements C403.2.7.3.1 ;Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans C403.2.7.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed C403.2.7.1 / 2 Duct insulation Indicate R-value of insulation on ductwork Piping Systems C403.2.8 Piping insulation Indicate R-value of insulation on piping C403.2.8.1 Piping insulation exposed to weather Indicate method of protection from damage/degredation SIMPLE SYSTEMS Qualifying Systems C403.3 Qualifying single zone systems Verify unitary or packaged equipment does not exceed capacity limits, does not have active humidification or simultaneous heating/cooling C403.3 Qualifying 2-pipe heating systems Verify 2-pipe heating -only system does not exceed capacity limits C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 Simple System Economizers C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equipment schedule C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA; note exceptions taken C403.3.1.1.2 Integrated air economizer operation Indicate capability for partial air economizer operation for systems with capacity > 65,000 Btu/h C403.3.1.1.3 Air economizer high limit controls Indicate high limit shut-off control method per Table C403.3.1.1.3(2) 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Permit Plans Checklist - Page 3 of 4 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Address 17672 Southcenter Pkwy Date Revised Aug 2015 1/1/2015 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes COMPLEX SYSTEMS Complex System Economizers C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equipment schedule C403.4.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) C403.4.1.1 Water economizer capacity For eligible systems where water economizer may be provided in lieu of air economizer, indicate system is capable of 100% cooling capacity at 50°F db/45°F wb OSA C403.4.1.2 Water economizer maximum pressure drop Indicate precooling coils and heat exchangers in water economizer system do not exceed pressure drop limit C403.4,1.3 Integrated economizer operation Indicate capability for partial economizer operation for air or water economizer systems C403.4.1.4 Economizer heating system impact Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation Specific System. Requirements._... C403.4.2 & C403.2.12 VAV fan control Indicate fans requiring variable flow control and method C403.4.2.1 VAV fan static pressure sensors Indicate sensor locations on plans; include at least one sensor per major duct branch C403.4.2.2 VAV fan static pressure setpoint Indicate fan system static pressure setpoint based on zone requiring most pressure C403.4.5 VAV systems serving multiple zones Indicate supply air systems serving multiple zones, method of primary air control, and zones served; Indicate VAV or note exceptions taken C403.4.5 VAV systems serving multiple zones For each air system terminal, indicate the maximum air flow rate of primary supply air during zone peak cooling and the maximum air flow rates during zone peak heating. C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads C403.4 Large capacity cooling systems Indicate method of multi -stage or variable control for building cooling system capacity > 300 tons C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method C403.4.3 Large capacity boiler systems Indicate multi -stage or modulating bumer for single boilers > 500,000 Btu/h C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers C403.4.3.5 Chiller / boiler plant pump isolation Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers & boilers when not in use C403.4.3.6 & C403.2.12 Variable flow control - pumps Indicate pumps requiring variable flow control & method C403.2.12.1 .& C403.4.4 Variable flow control - cooling towers Indicate cooling tower fans requiring variable flow control and method C403.4.3.4 Hydronic system part load controls Indicate heating & chilled water systems have the capability to automatically reset supply water temp AND reduce flow by ' 50% for systems > 300,000 Btu/h C403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling mode scheduling and changeover temperature range C403.4.3.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide min. 20°F water supply temp deadband between heat rejection and heat addition modes C403.4.3.3.2.1 Water loop heat pump - heat rejection, Zone 4 Indicate method used to limit system heat loss when heat rejections is not needed C403.4.3.3.2.2 Water loop heat pump - heat rejection, Zone 5 Provide heat exchanger that separates cooling tower and heat pump loop C403.4.3.3.3 Water loop heat pump - isolation Indicate 2-way isolation valve on each heat pump and variable flow control for systems with total pump power> 10 hp C403.5 Walk-in cooler / freezer - anti -sweat heaters Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters C403.5 / 6 Cooler / freezer - evaporator and condenser fans Indicate motor type for evaporator and condenser fans < 1 hp 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Permit Plans Checklist - Page 4 of 4 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commer 2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Address 17672 Southcenter Pkwy Date 1/1/2015 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes SERVICE WATER HEATING Service Water Systems C404.2 Water -heating equip min. efficiency Provide equipment schedule with type, capacity, efficiency, test standard or other efficiency source C404.3 Temperature controls Indicate temperature controls have required setpoint capability C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & discharge C404.5 Insulation under water heater Indicate R-10 insulation under electric water heater tanks C404.6 Service water piping insulation Indicate R-value of insulation on piping; note exceptions taken C404.7 / 8 Circulation systems and heat trace shut-off Indicate shut-off capability based on occupancy and periods of limited demand C404.9 . Group R-2 service hot water meters Indicate method of usage metering for dwelling units served by a central service hot water system Pools & In -Ground Permanently Installed Spas C404.10.1 Pool heating equip min. efficiency Provide equipment schedule with type, capacity, efficiency, test standard or other efficiency source C404.10.1 / 2 Pool heater on / off controls Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting; note exceptions taken C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use; note exceptions taken COMMISSIONING Specific System Requirements C408 2 Mechanical systems commissioning Indicate all mechanical systems to be commissioned; for those that will not be commissioned, note exception taken C408.4 Service water heating systems commissioning Indicate all service water heating systems to be commissioned; for those that will not be commissioned, note exception taken C408.1.1 Commissioning plan Provide commissioning plan for all systems requiring commissioning; include in plan all required items per this section C408.2.2.1 & C408.2.2.2 Air system and hydronic system balancing Include in commissioning plan that air and hydronic systems shall be balanced in a manner to first minimize throttling losses, then adjust to meet design flow conditions C408.2.2.1 Air system balancing devices Indicate devices that provide the capability to balance all supply air outlets, zone terminals and equipment requiring system balancing C408.2.2.2 Hydronic system balancing devices Indicate devices that provide the capability to isolate, balance and measure flow for all hydronic equipment requiring system balancing C408.2.3 Mechanical systems functional performance testing Provide description of functional performance testing procedures for all applicable systems including: equipment, controls, economizers — --- C408.4.1 Service water heating functional performance testing Provide description of functional performance testing procedures for all applicable systems including: equipment, controls, pools and spas C408.1.4 Systems operation training Indicate required systems operation training measures to be provided C408.1.2 & C403.1.3 Documentation Indicate required documentation including: record documents, manuals, balancing reports, commissioning preliminary and final reports C408.1.2.1 Acceptance report Indicate that Commissioning Compliance Checklist (Figure C408.1.2.1) is required upon completion of preliminary commissioning report 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Economizer Exceptions Alterations/Simple Systems MECH-ECONO 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Info Project Address: 17672 Southcenter Pkwy Date 1/1/2015 Tukwila, Washington 98188 For Building Dept. Use Fill this line out on MECH-SUM Applicant Name: Wolfer's Inc Applicant Address: 1365 N. Front St Woodburn, Or 97071 Applicant Phone: 503-220-1901 Economizer Exception Economizer Exceptions - Alterations or Replacement Table Alterations or replacement of existing mechanical equipment System ID Equipment Type Compliance Path Summary C101.4.3.1 may comply with an applicable economizer compliance Option as defined in Table C101.4.3.1. RTU-1 1. Packaged Units Option A RTU-2 1 •Packaged Units Option A RTU-4 1. Packaged Units Option A RTU-5 1. Packaged Units Option A RTU-6 1. Packaged Units Option A -- — - - -- RTU-7 1 •Packaged .Units . Option A - --- - - --- Refer to Section C403.3.1 and C403.4.1 for Economizer Exceptions - Simple Systems SS Exp1 Qualifying small equipment. Per unit limit is 33,000 Btu/h. Per building capacity limit for this exception is 72,000 Btu/h or 5% of required building System ID Cooling Capacity (Btu/h) descriptions of air economizer capacity, whichever is greater. Efficiency shall be 15% economizer better than required minimum. Not eligible: non -unitary equipment, unitary installed in room to outdoors, provisions and For equipment outdoors or mech adjacent equipment installed during new construction, shell -and -core construction, exceptions. alterations refer or initial tenant improvement. to Section C101.4.3.2 and Table Total Claimed Exempt Capacity: C101.4.3.1. Total building air economizer capacity (if claimed > 72,000 Btu/h): Alternate SS Exp1 Capacity Limit: SS Exp2 Systems with dehumidification that affect other systems such that air System ID economizer would increase energy consumption. SS Exp3 Group R cooling equipment. Per unit limit is 20,000 Btu/h for simple cooling equipment installed outdoors or in a mech room adjacent to the outdoors. For simple cooling equipment installed System ID Equipment Location Cooling Capacity (Btu/h) in other locations the unit limit is 54,000 Btu/h. Efficiency shall be 15% better than required minimum. SS Exp4 Pending rule per WAC 51-11 C-40331. Equipment cooling efficiency meets 'System ID or exceeds 64% in Climate Zone 4C and 59% in Climate Zone 5B per revised Table C403.3.1(2). SS Exp5 Simple cooling equipment for dedicated server rooms, electronic equipment rooms (including elevator machine rooms), or telecom switch rooms. These systems are eligible under CS Exp5 . The total allowance for equipment utilizing this exception includes the sum of both simple and complex systems. Document under CS Exp5 - -.,.. _ _. W,.. , » _- ._. _ T 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Economizer Exceptions, Complex Systems MECH-ECONO 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Economizer Exception _ _ Summary Refer to Section C403.3.1 and C403.4.1 for descriptions of economizer provisions and exceptions. For alterations refer to Section C101.4.3.2 and Table C101.4.3.1. Project Address: 17672 Southcenter Pkwy Date 1/1/2015 Economizer Exceptions - Complex Systems Water Economizer Capacity (tons) — _ CS Exp1 Water-cooled chilled beam and chilled ceiling systems with water economizer. Capacity limit for all water economizer systems is 500 tons per building. Total building water economizer capacity (tons System ID - all systems): CS Exp2 Water -source heat pumps with heat recovery. Heat pump efficiency shall be 15% better than required minimum. Provide at minimum 60% air economizer. Energy recovery to preheat OSA shall have at least 50% effectiveness. Additional system requirements apply. System ID Y CS Exp3 Chilled water terminal units. Part load efficiency of chilled water generation equipment shall be 25% better than required minimum. building limit of all systems without air economizer is 480,000 Btu/h 20% of required building air economizer capacity, whichever is greater. — —_. - Total Per or Claimed Exempt (if claimed > CS Exp3 System ID Cooling Capacity (Btu/h) Capacity: 480,000 Btu/h): Capacity Limit: Total building air economizer capacity Alternate CS Exp4 Group R cooling equipment. Per unit limit is 20,000 Btu/h for equipment installed outdoors or in a mech room adjacent to the outdoors. For cooling equipment installed in other locations the unit limit is 54,000 Btu/h. Efficiency shall be 15% better than required minimum. System ID Equipment Location Cooling Capacity (Btu/h) CS Exp5 Equipment for dedicated server, electronic equipment or telecom switch rooms. Per building limit of all systems without air economizer is 240,000 Btu/h or 10% of required building air economizer capacity, whichever is greater. Part load control required over 85,000 Btu/h. Additional requirements apply. Option a - Efficiency shall be 15% better than required minimum. Option b - Efficiency shall be 5% better than required minimum. Waterside economizer required. Option c - All cooling equipment is subject to ASHARE Standard 127. Waterside economizer required. Option d - Chiller efficiency shall be 25% better than C403.2.3(7) full load and part load minimum. No economizer required. Option e - Chiller efficiency shall be 10% (air cooled) /15% (water cooled) better than C403.2.3(7) minimum. Dedicated waterside economizer required. Total Total building air economizer capacity Alternate System ID Compliance Option Cooling Capacity (Btu/h) - - - Claimed Exempt Capacity: (if claimed> 240 kBtu/h): CS Exp5 Capacity Limit: - - — - • CS Exp6 Variable refrigerant. flow (VRF) systems with energy recovery. Limited buildings 60,000 sf or less. Outdoor unit min. capacity is 65,000 Btu/h. Energy recovery to preheat OSA shall have at least 50% effectiveness. Zones served shall be at least 20% interior and 20% perimeter. Additional requirements apply. to System ID Outdoor Unit Cooling Capacity (Btu/h) 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Fan System Power Allowance MECH-FANSYS-SUM 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Au a 2015 Project Info Project Address: 17672 Southcenter Pkwy Date 1/1/2015 Tukwila, Washington 98188 For Building Dept. Use Fill this line out on MECH-SUM Applicant Name: Wolfer's Inc Applicant Address: 1365 N. Front St Woodburn, Or 97071 Applicant Phone: 503-220-1901 HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. Fan System ID Speed Control (Note 1) Description System Total Nameplate HP (Note 2) Fan Power Calculation (Note 3) RTU-1 CV Rooftop Heat pump 1 hp < 5 hp RTU-2 CV Rooftop Heat pump 1 hp < 5 hp RTU-4 CV Rooftop Heat pump 7.5 Yes RTU-5 CV Rooftop Heat pump - --•--7:5 •- —- - • Yes RTU-6 CV Rooftop Heat pump 1 hp < 5 hp RTU-7 CV Rooftop Heat pump 1 hp < 5 hp Note 1 - Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualities for VAV budget per C403.2.10.1 Exception 1. Single zone VAV systems shall comply as CV. Note 2 - Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Include all supply, retum/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan -powered terminals. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. Note 3 - Indicate if MECH-FANSYS form is required (Yes), or the system is not required to provide this information because it has a combined total nameplate motor hp less than 5 hp (< 5 hp) or the system is ventilation only and thus has no heating or cooling capacity (No). MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select (Add Fan System Form) to generate an additional form. Added forms can be deleted with button in cell E38 of the added 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Fan System Power Allowance MECH-FANSYS 12 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Info Project Address: 17672 Southcenter Pkwy Date 1/1/2015 Tukwila, Washington 98188 For Building Dept. Use Fill this line out on MECH-SUM Applicant Name: Wolfer's Inc Applicant Address: 1365 N. Front St Woodburn, Or 97071 Applicant Phone: 503-220-1901 Fan System ID Y A separate MECH-FANSYS form must be completed for every HVAC system that exceeds the 5hp threshold. System Supply Fan Speed Control Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403.2.10.1, Exception 1 Compliance Option Compliance is based upon either the fan motor nameplate horse power (Option 1) or the fan brake horsepower (Option 2). The bhp calculation provides adjustments for special equipment per Table C403.2.13.1(2). Fan System Supply Y pP y CFM Total 16,000 Provide maximum design supply airflow rate (CFM) of all supply fans serving the conditioned space in Fan Equipment Schedule below. Fan System CFM Total is the supply airflow of the central air handler at peak design conditions. Additional volumetric air flow provided at zone fan terminals, booster fans, or through induction is not included in the supply CFM total. However, the fan power of this equipment is included in the HP and BHP calculations. Fan Equipment Schedule Fan ID and Location Fan Type Quantity of Fan Type Total CFM (Note 1) Total Nameplate HP (Note 2) Total BHP (Note 3) RTU-4 Supply 1 8,000 7.5 RTU-5 Supply 1 8,000 7.5 Note 1 - Total CFM is the maximum CFM of the listed fan(s) when operating at peak design operating conditions. Note 2 - Total namplate hp of the listed fan(s). Note 3 - Total brake horsepower (bhp) of the fisted fan(s) at peak design operating conditions. Not required if Nameplate HP compliance option chosen. Compliance Message: Total Proposed: Total Allowance: 15.0 Enter speed control in B10 Brake Horsepower Allowance Adjustments Device Type Description and Location CFM thorough this device (CFMD) Assigned Pressure Drop, PD in w.c. (Note 5) Calculated Pressure Drop, PD in w.c. (Note 6) Adjustment, A in bhp (Note 7) Note 4 - Bhp allowance for energy recovery devices and run around coil loops includes both air Total Adjustment (bhp): — ` the device. Note 5 - Assigned pressure drop (PD) adjustment per Table C403.2.10.1(2). Note .6 - Pressure drop (PD) adjustment shall be calculated per the applicable method defined in Table C403.2.10.1(2) based on specific system conditions. Note 7 - A = PD * CFMD/4131 where A is the allowed system brake horse power adjustment, PD is pressure drop allowance, and CFMD is the cfm through the device. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 General Instructions: A. Include all fans directly associated with the delivery and removal of conditioned air to the zones served by the system. Enter CFM and brake horsepower (bhp) of each fan at peak design conditions and the nameplate horsepower (hp). Include supply, retum and relief fans, exhaust and exhaust hood fans (>1 hp), booster fans and fans included as part of make-up air units, dedicated outside air systems(DOAS), energy recovery ventilators (ERV), and series fan -powered terminal equipment. B. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. C. Fans not directly associated with the delivery and removal of conditioned air, such as condenser fans, do not need to be included in the fan power total. D. Fan power calculations are not required for non -central air HVAC systems such as 4-pipe fan coils and variable refrigerant flow (VRF) systems unless individual fan systems are greater than 5hp. E. In the Brake Horsepower Allowance Adjustments table, if a Device Type is selected that has an Assigned Pressure Drop, this value will autofill into the Assigned Pressure Drop cell and the Calculated Pressure Drop cell will be write -protected. If the Device Type requires a Calculated Pressure Drop, then enter this value into the Calculated Pressure Drop cell and the Assigned Pressure Drop cell with be write -protected. F. Refer to FAQ section of MECH-FANSYS-DOC for additional instructions. y- 0 O) 13 N j (1) Ct CO CC 1D a3 N Z" 0 M A 0 0 0 cc as � (0 a) E ca E O U o �O M fn E O U W °3 cc Ca Et .Q CU C Ear o U Z5 a) E .N U a 13 C - c0 Ll � /vim.) 'F2 W w N j .ids u_ N T c W DI U °' .470 U Ww Oa N ru N t6 N_ O N 0 U LO 1-1 0 N 1 1-1 N ca 0 For Building Dept. Use Cooling System Economizer exception - required % higher efficiency (0 O V a0 N N CO a) 0, U 0 cowZ W W N C fh N U p W W Z 13 Seer 0 M 0 M 1- 13.00 - - M 13.00 — - Cooling Capacity, Btu/h (Note 2) 61,500 O o N CO 226,000 226,000 O O 1` M 61,500 Project Address: 17672 Southcenter Pkwy Tukwila, Washington 98188 Fill this line out on MECH-SUM Applicant Name: Wolfer's Inc (Applicant Address: 1365 N. Front St Woodburn, Or 97071 Applicant Phone: 503-220-1901 Condenser or Sub - Type Air-cooled, Elec. Res. or No Heat Air-cooled, Elec. Res. or No Heat Air-cooled, Elec. Res. or No Heat Air-cooled, Elec. Res. or No Heat Air-cooled, Elec. Res. or No Heat Air-cooled, Elec. Res. or No Heat Equipment Type Heat pump Heat pump Heat pump H Z t pump Heat pump Heat pump WSEC Efficiency Table C403.2.3(2) Unitary & Applied Heat Pumps C403.2.3(2) Unitary & Applied Heat Pumps C403.2.3(2) Unitary & Applied Heat Pumps C403.2.3(2) Unitary & Applied Heat Pumps C403.2.3(2) Unitary & Applied Heat Pumps C403.2.3(2) Unitary & Applied Heat Pumps Heating and/or Cooling Systems (Note 1) Area(s) Served as Ce as CL ea re ea re Office Retail Project Info The following information shall be included in the mechanical equipment schedules in the permit documents. For projects without plans, provide the required information below. Make & Model Lennox KHA060 Lennox KHA060 Lennox KHA240 Lennox KHA240 Lennox K1A036 Lennox KHA060 ci Q— W ' 1- Q' N H Q' 1' 1- Q' h 1- Q' l0 1- R' 11- H R' Q. 0 0 CC 0 0 N E LU 5 W O Et- UJ G W o Cr) to c a) •a 0) o N t`') zzZ CC cO N CC 0 C•) A f6 a O 0 f6 N E E O U E 0 LL U Os Q E O U m O U A C) 4) w a) c 0 :c w O N N a) co a i V ) W eL W ca a) 2 06 0 0 U 1.0 1-1 0 N -1 a) For Building Dept. Use Air System Ventilation Energy Recovery (Yes or Not required) Q Z Q 2 Q Z Q Z Q Z Q Z Zone DCV or Occ. Sensors (Indicate type & zones(s) if required) c 0 cU Project Address: 17672 Southcenter Pkwy Tukwila, Washington 98188 Fill this line out on MECH-SUM Applicant Name: Wolfer's Inc Applicant Address: 1365 N. Front St Woodburn, Or 97071 Applicant Phone: 503-220-1901 M u_ >, Q in 2,000 coU o N 8,000 8,000 1,200 2,000 Heating System U a) a) a) N 'U O c Z w Capacity, BtU/h (Note 5) 59,710 59,710 220,430 220,430 351,670 0 n in Sub -type or Fuel Air-cooled, Elec. Res. or No Heat Air-cooled, Elec. Res. or No Heat Air-cooled, Elec. Res. or No Heat Air-cooled, Elec. Res. or No Heat I Air-cooled, Elec. Res. or No Heat Air-cooled, Elec. Res. or No Heat Equipment Type Heat pump Heat pump Heat pump G _E 3 Q a HLat pump Heat pump Project Info The following information shall be included in the mechanical equipment schedules in the permit documents. For projects without plans, provide the required information below. WSEC Efficiency Table C403.2.3(2) Unitary & Applied Heat Pumps C403.2.3(2) Unitary & Applied Heat Pumps C403.2.3(2) Unitary & Applied Heat Pumps C403.2.3(2) Unitary & Applied Heat Pumps C403.2.3(2) Unitary & Applied Heat Pumps C403.2.3(2) Unitary & Applied Heat Pumps a 0— w RTU-1 RTU-2 RTU-4 RTU-5 RTU-6 RTU-7 vi Q E m a 3a)c o a) a3 jC aa) o a 2,w h m 0. 3�Z Or r-0 v Wrnc• a'0 0o Z Q. O NZ 3aciz E N 3 c O y ,U Q) cb a)L. o a, a°� q;mLo. Ufa.13 fa. e U O a0)°ic ecr c. m � UJ W ai'n t0 c U A,N U a) mom. m „•„ O O vi m ?- E u 0. Q. a) N a„)O cc)t L. �w.c,)� a)�a)= a) OO U 2-0 0. 0o. C N O N c E U E 2 or ' o- a) a)ma)U COL.mk a) iW�°w LO co CD o O O zzz L1 LENNOX Product Submittal Project Information Project Name: ROSS # 44 TUKWILA, WA Project Number: 3000456030 Project Location: 17672 SOUTH CENTER PKWY TUKWILA, WA 98188, US Project Altitude: 138 Customer Information Company Name: Ross Dress For Less Company Address: 5130 Hacienda Drive Company Location: Dublin, CA 94568 Contact: Phone: 925-965-4400 Engineering Information Company Name: Company Address: Company Location: Contact: Phone: RE VVED FOR CODE COMPLIANCE APPROVED OCT 21 2015 City of Tukwila BUILDING DIVISION We are pleased to provide the attached project submittal. If you have any questions or need additional information, please feel free to call our office. RECEIVED CITY OF TUKWILA OCT 1.3 2015 M1oI3s Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 1 of 18 Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 PERMIT CENTER Lennox Industries Inc. - Product Submittal Table of Contents System ID Qty Model Description RTU - 1,2,7 3 KHB060S4B PKGHP/5TON/BTO RTU - 4,5 2 KHA240S4M PKGHP/20TONBTO RTU - 6 1 KHB036S4B PKGHP/3TON/BTO Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 2 of 18 Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 Lennox Industries Inc. - Product Submittal System ID: RTU - 1,2,7 Package Model: KHB060S4B Description: PKGHP/5TON/BTO HEATING PERFORMANCE Unit Type HP Output@Design H/E HighOutput System HeatOutput Packaged Heat Pump 57540 (Btuh) 47037 (Btuh) 104577 (Btuh) HP DesignTemp Electric Heater H/E Heat Rise 47.0 (°F) 15.0 (kW) 21.8 (°F) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool R-410A 11.9 14.0 5000 (W) 62600 (Btuh) 60000 (Btuh) 57300 (Btuh) 54287 (Btuh) 44121 (Btuh) 41108 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 1 1.00 (in.) 105.0 (°F) 80.0 (°F) 67.0 (°F) 59.0 (°F) 57.6 (°F) 60.3 (°F) 58.1 (°F) 12.4 (lb/hr) 12.4 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 2000 (cfm) 1.00 (in.WC) 0.96 (hp) 1.00 (hp) CAV Belt Drive 1269 (rpm) 1212 (rpm) 1548 (rpm) TotalStaticPress Wet Coil Static Press Electric H/E Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 1.28 (in.WC) 0.05 (in.WC) 0.18 (in.WC) 0.05 (in.WC) 4 20.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range-Nom Voltage 460V 3Ph 60 (Hz) 36.0 (amp) 40 (amp) 8.0 (amp) 11.4 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 2.1 (amp) 1.3 (amp) 405 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight Horizontal Supply Height Horizontal Supply Width 47.0 (in.) 83.3 (in.) 43.4 (in.) 848 (lb) 19.5 (in.) 20.0 (in.) Horizontal Return Height Horizontal Return Width 11.0 (in.) 29.0 (in.) SOUND Outdoor Sound Rating 81 (db) Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 3 of 18 Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 Lennox Industries Inc. - Product Submittal System ID: RTU - 1,2,7 Package Model: KHB060S4B Description: PKGHP/5TON/BTO SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor High Capacity Driers Separate Compressor and Controls Compartment High Pressure Switch (Manual Reset) Crankcase Heater Test Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED BAROMETRIC RELIEF DAMPERS CONSTANT AIR VOLUME BELT DRIVE BACNET CONTROL MODULE BAROMETRIC RELIEF DAMPERS GFCI - FACTORY INSTALLED/NON-POWERED CORROSION PROTECTION 2 IN MERV4 FILTER DISCONNECT - WEATHERPROOF SINGLE ENTHALPY ECONOMIZER INCLUDED SYSTEM OPTIONS FIELD INSTALLED 97W23 17W45 14W40 53W79 41W34 3 3 3 3 3 BACNET SENSOR WITH DISPLAY STE-8001 FDHECKOOAN1 HORIZ. ECONO CONVERSION KT T1EH0150AN1G 15KW 460-3 C1SNSR43AP1 SUP & RET SMOKE DETECTOR KT KISNSR13A-1 LOW AMBIENT KIT - KH (A BOX) Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 4 of 18 Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 Lennox Industries Inc. - Product Submittal System ID: RTU - 1,2,7 Package Model: KHB060S4B Description: PKGHP/5TON/BTO MENSIONS -'UNIT - I IE Model No. AA Base lbs. kg Max. lbs.: kg BB Base lbs. kg CORNER Max. lbs. kg WEIGHTS CC Base lbs. kg Max. lbs. kg Base lbs. kg DD Max. tbs. kg CENTER EE Base. in. mm OF Max. in, mm GRAVITY FF Base in. mm Max. in. mm 024 117 53 138 62 145 66 150 66 162 73 167 76 130 59 '197 89 38 965 43-314 1111 22-114 565 22-1 /4 565 030 117 53 138 62 145 66 150 68 162 73 167 76 130 59 197 89 38 965 43-3/4 1111 22-11456522-1/4565 036 117 .53 136 62 145 66 150 68 162 73 167 76. 130 59 197 89 36 .:965 43-3/4 1111 22-1/456522-114 565 046 133 60 157 71 165 75 171 78 195 89 242 110 157 71 200 91 38 965 39-112 1003 21-1i2546 19-1/2 495 060 136 62 159 72 169 77 173 79 201 9'1` 244 111 161 73 202 92 38 965 39-1/2 1003 21-11254619-112495 Ease Unn- Tne ur t ash standard heat exchana NO OPTIONS. Max.. Unit -Tam 7.w h7,LL0FTIONSinst d.lEccnorl r,eic.l + EE Ate 9CTT0MPOW1-.12 ENTRY :t X e( eX2O3p: TOP VIEW (Base) 4.s ,aiaa-41 loo 1. .�.� ,1 act d'r fis§i) END VIEW SIDE VIEW �tit- T2. 44%) {4a7) tea III !I limp, II 11111 IIl I I.,► IIIII1 1011 III / oo Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 5 of 18 FORKLIFT :ACTS 5t 142 ;I-1 {Fcal,Sad( anti i40,t SUPPLY EMacex Enc.".OPEN BACK VIEW Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 BB CC Lennox Industries Inc. - Product Submittal System ID: RTU - 1,2,7 Package Model: KHB060S4B Description: PKGHP/5TONBTO OUT0100R AIR i tt3t D i (Horizontal Applications) SUPPLY AIR DUCT Fidd?ma Jodi ROLL OUTLET TOP VIEW 1.. fD BAR 7. 'ECONOMIZER DA1 PE:Z; RETURN AIR: C'"t13T TR/W=0N 4F'6ak1Iiihttalrtd and iied+ydanurPII !I lil'.11111 I I I I1'11 I t II t t l I 1 1 ids T&�. K�ICYNaa M T "_3 T i r 55�20 i stcrator L__J CMG BA K 7 TETLIRN AR INLET OUTDOORAIR HOOD Ert&md Storrdrnixa) REL.9 TURN AIR i3T (Roil Rittdddiod P 1lsc iao rand it azaxnntadatdtrornzezt ROAOf Hots dand Rtdunfk*Row net t EAROAETRlC Rrt'1rF HOOD DIMENSIONS VIcL` 190 rorOI tktglC ,21r2r aavaa6, ma) 5 F.t635O I030.,072¢ Soo ,.ena7:ie*,:e?a decal:. NOTE i i ri r ttI dd i4sx ' Hotizamtal a smrtimr 8 4141., SaisCiatmlA:xmswNos afo. BA -ROM ETP4C RE:Er 1{ r3D 4:`crra- od,Oticxrn n ere8 Add Est zad en Feld `..tr=r tnd r'larin Ai Eke* ,R. ooj T 5<i 2 RE.ni N AIR 040 i lurT+RdgNSTION WRidtbrignIed dod toottIotl on wit NO••TE. - Re. teA'T L TURN AIR S71JTT 1st ET Fedd %'atrc+and - Mud trt .mad 1e ddo:ro tnclatoOdocrlaei,Rolef Hbod sod A 1r11usReglatrtterrr' I: Tim aal 4 2.1,4 - 3 7.18 __ .w � x ;fey, a r,• r—s1 C,,= 00 7,m Model No. A rn mm 024, 030, 03G, 048 060, 072 18-314 475 22-1,2 572 in. 11-3t'4 1 5-34 B mm 288 400 Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 6 of 18 cri.t 60A77 v txr s Os4:66U W674 E Y MZ�A END VIEW Last Changed: SAM WIESE Prepared On:.2015-09-30 Phone: 972-497-6301 Lennox Industries Inc. - Product Submittal System ID: RTU - 1,2,7 Package Model: KHB060S4B Description: PKGHP/5TON/BTO UNIT CLEARANCES - INCHES (MM) C 1 OUTDOOR MR raoo �— D —► —► A 1 Unit Clearance in. A mm B in. mm C in. mm D in. mm Top Clearance Service Clearance 36 914 36 914 36 934 36 914 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. 1 Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required dearance for proper unit operation. Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 7 of 18 Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 Lennox Industries Inc. - Product Submittal System ID: RTU - 4,5 Package Model: KHA240S4M Description: PKGHP/20TONBTO HEATING PERFORMANCE Unit Type HP Output@Design H/E HighOutput System HeatOutput Packaged Heat Pump 220430 (Btuh) 94075 (Btuh) 314505 (Btuh) HP DesignTemp Electric Heater H/E Heat Rise 47.0 (°F) 30.0 (kW) 10.9 (°F) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Refrigerant Charge R-410A 10.6 13.0 20500 (W) 226000 (Btuh) 218000 (Btuh) 213500 (Btuh) 198505 (Btuh) 170800 (Btuh) 155805 (Btuh) 52 LBS. O OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 2 2 1.00 (in.) 105.0 (°F) 80.0 (°F) 67.0 (°F) 59.7 (°F) 58.3 (°F) 61.4 (°F) 58.9 (°F) 40.3 (lb/hr) 40.3 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 8000 (cfm) 1.00 (in.WC) 5.25 (hp) 7.50 (hp) MSAV Belt Drive 960 (rpm) 850 (rpm) 1045 (rpm) TotalStaticPress Electric H/E Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness Number Exhaust Fans 1.11 (in.WC) 0.02 (in.WC) 0.09 (in.WC) 6 24.0 (in.) 24.0 (in.) 2.0 (in.) 2 ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range-Nom Voltage 460V 3Ph 60 (Hz) 102.0 (amp) 110 (amp) 33.4 (amp) 49.6 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 11.0 (amp) 5.2 (amp) 1500 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 91.1 (in.) 129.5 (in.) 54.3 (in.) 2298 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 15.0 (in.) 60.5 (in.) SOUND Outdoor Sound Rating 93 (db) Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 8 of 18 Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 Lennox Industries Inc. - Product Submittal System ID: RTU - 4,5 Package Model: KHA240S4M Description: PKGHP/20TONBTO SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor High Capacity Driers Separate Compressor and Controls Compartment High Pressure Switch (Manual Reset) Crankcase Heater Test Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED MULTI -STAGE AIR VOLUME BELT DRIVE BACNET CONTROL MODULE GFCI - FACTORY INSTALLED/NON-POWERED CORROSION PROTECTION HINGED DOORS 2 IN MERV4 FILTER DISCONNECT - WEATHERPROOF SINGLE ENTHALPY ECONOMIZER INCLUDED SYSTEM OPTIONS FIELD INSTALLED 54W78 97W23 75W91 53W94 83W41 55W73 54W67 90W52 EOC 2 2 2 2 2 2 12 2 2 C1DAMP50C-1 GRAVITY EXHAUST BACNET SENSOR WITH DISPLAY STE-8001 C1PWRE11C-1G POWER EXHAUST 460-3 CIEH0300C21G 30KW ELECTRIC HEAT C 1 SNSR43C-1 SUP & RET SMOKE DETECTOR KT K1SNSR33CS1 LOW AMBIENT CONTROL 100929-03 FILTER - MERV 8 24 X 24 X 2 VFD BYPASS C 3/5HP V VOLT 3-10HP G J Third Party EOC & GUIDED SETUP Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 9 of 18 Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 Lennox Industries Inc. - Product Submittal System ID: RTU - 4,5 Package Model: KHA240S4M Description: PKGHP/20TONBTO DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF Ibs. kg Ibs. kg Ibs. kg Ibs. kg in. mm in. mm KHA180 Std. Unit 385 182 466 220 602 284 497 235 59 1499 39-3/4 1010 KHA180 Max. Unit 492 232 548 258 648 306 582 275 56-3/4 1441 41-3/4 1060 KHA240 Std. Unit 423 199 497 235 665 314 565 267 58-1/4 1480 39 991 KHA240 Max. Unit 536 253 580 274 709 335 655 309 56 1422 41 1041 Std. Unit - The unit with NO OPTIONS. Max. Unit - The unit with ALL OPTIONS Installed. (Economizer, etc.) 90-1/8 (2289) (743) CONDENSATE DRAIN 1 54-1/4 51 (1295) 5-3/8j(137) 0 0 0 SIDE ELECTRICAL 3-1/4 INLETS (83) 91-1/8 (2315) BASE I (1378) 4-1/4 (108) 12-3/8 ,A + 60-1/2 (1537) (314) 15 (381) BOTTOM RURN f ETAIR OPENING BOTTOM SUPPLY 18 (457()AIR OPENINGS ` I (314) 12--3/8 28�� N28 T_ 1 [<1� (711) 777���111 g)1j 114) * (ice) OF EE CENT ER GRAVITY 4 (102) FF D BOTTOM POWER ENTRY ;04) 127 X 203 mm (5 X 8 in.) 2 TOP VIEW (3264) OUTDOOR COILS it et, Q = oe a LIFTING HOLES (For Rigging Front and Back) FORKLIFT SLOTS (Front and Lett Sides Only) 129-1/2 (3289) BASE END VIEW SIDE VIEW Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 10 of 18 Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 BB CC Lennox Industries Inc. - Product Submittal System ID: RTU - 4,5 Package Model: KHA240S4M Description: PKGHP/20TONBTO OPTIONAL OUTDOOR AIR HOOD DETAIL WITH STANDARD STATIC POWER EXHAUST FANS 16 r (406) OPTIONAL OUTDOOR AIR HOOD (Field tnstaBed) Required wtlh Economizer or Outdoor Air tamper OPTIONAL STANDARD STATIC POWER EXHAUST FANS HOOD (Field Inst3Bed) Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 11 of 18 1 Field Installed in Return Air Duct for Horizontal Applications. HORIZONTAL BAROMETRIC RELIEF DAMPERS (Field installed in horizontal retum air duct adjacent to unit) 31-5/8 (803) 29-1/2 (749) FRONT VIEW NOTE - Two fumished per order no. 1 NOTE - Opening size required in return air duct. 6-1/2 (165) SIDE VIEW Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 Lennox Industries Inc. - Product Submittal System ID: RTU - 4,5 Package Model: KHA240S4M Description: PKGHP/20TONBTO UNIT CLEARANCES - INCHES (MM) Unit With Economizer 1/, 7/AIR /f/ �/ /1I our000R HOOD i-A .E D 4 ,-T: 7, 4 ...z B 70- 4 - j/�� iAv ll/ Note: 2 300 sizes shown 1 Unit Clearance A B C D Top Clearance in. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 36 934 66 1676 Unobstructed Minimum Operation Clearance 45 1143 36 914 36 914 41 1041 NOTE - Entire perimeter of unit base requires support when elevated al ove the mounting surface. Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 12 of 18 Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 Lennox Industries Inc. - Product Submittal System ID: RTU - 6 Package Model: KHB036S4B Description: PKGHP/3TON/BTO HEATING PERFORMANCE Unit Type HP Output@Design H/E HighOutput System HeatOutput Packaged Heat Pump 36170 (Btuh) 23519 (Btuh) 59689 (Btuh) HP DesignTemp Electric Heater HIE Heat Rise 47.0 (°F) 7.5 (kW) 18.2 (°F) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool R-410A 11.5 14.0 3000 (W) 36300 (Btuh) 35000 (Btuh) 33400 (Btuh) 31862 (Btuh) 26720 (Btuh) 25182 (Btuh) Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 1 1.00 (in.) 105.0 (°F) 80.0 (°F) 67.0 (°F) 58.8 (°F) 57.9 (°F) 59.9 (°F) 58.3 (°F) 6.3 (lb/hr) 6.3 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 1200 (cfm) 1.00 (in.WC) 0.49 (hp) 1.00 (hp) CAV Belt Drive 1126 (rpm) 897 (rpm) 1346 (rpm) TotalStaticPress Wet Coil Static Press Electric HIE Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 1.12 (in.WC) 0.02 (in.WC) 0.06 (in.WC) 0.04 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range-Nom Voltage 230V 3Ph 60 (Hz) 40.0 (amp) 40 (amp) 8.7 (amp) 15.0 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 4.6 (amp) 1.7 (amp) 240 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight Horizontal Supply Height Horizontal Supply Width 47.0 (in.) 83.3 (in.) 36.4 (in.) 701 (lb) 19.5 (in.) 20.0 (in.) Horizontal Return Height Horizontal Return Width 11.0 (in.) 29.0 (in.) SOUND Outdoor Sound Rating 75 (db) Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 13 of 18 Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 Lennox Industries Inc. - Product Submittal System ID: RTU - 6 Package Model: KHB036S4B Description: PKGHP/3TON/BTO SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor High Capacity Driers Separate Compressor and Controls Compartment High Pressure Switch (Manual Reset) Crankcase Heater Test Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED BAROMETRIC RELIEF DAMPERS CONSTANT AIR VOLUME BELT DRIVE BACNET CONTROL MODULE BAROMETRIC RELIEF DAMPERS GFCI - FACTORY INSTALLED/NON-POWERED CORROSION PROTECTION HINGED DOORS 2 IN MERV4 FILTER DISCONNECT - WEATHERPROOF SINGLE ENTHALPY ECONOMIZER INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 97W23 17W45 14W35 53W79 41W34 1 1 1 1 1 BACNET SENSOR WITH DISPLAY STE-8001 FDHECKOOAN1 HORIZ. ECONO CONVERSION KT T1EH0075ANIY 7.5KW 208/230-3 C 1 SNSR43AP 1 SUP & RET SMOKE DETECTOR KT K1SNSR13A-1 LOW AMBIENT KIT - KH (A BOX) Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 14 of 18 Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 Lennox Industries Inc. - Product Submittal System ID: RTU - 6 Package Model: KHB036S4B Description: PKGHP/3TON/BTO DIMENSIONS - UNIT - INCHES ( ) KHB Model No. AA Base Ibs, kg Max. lbs. kg BB Base lbs. kg CORNER Max. lbs, kg WEIGHTS CC Base Ibs. kg Max. lbs, kg Base Ibs. kg DD Max. lbs. kg CENTER EE Base in. mm OF Max. in. mm GRAVITY FF Base in. mm Max. in. mrn 024 117 53 138 62 145 66 150 68 162 73 167 76 130 59 197 89 38 965 43-3/4 1111 22-1/4565 22-114 565 030 117 53 138 62 145 66 156 68 162 73 167 76 130 59 197 89 38 965 43-3/4 1111 22-1/4565 22-1 /4 565 036 117 53 138 62 145 66 150 68 162 73 167 76 130 59 197 89 38 965 43-314 1 11 22-114565 22-114 565 648 133 60 157 71 165 75 171 78 195 89 242 110 157 71 200 91 38 965 39-1/2 1063 21-112546 19-1/2 495 060 136 62 159 72 169 77 173 79 201 91 244 111 161 73 202 92 38 965 39-1/2 1003 21-1/2546 19-112495 Saw Unit - The ,untrt yeth standard ileat. exchanger NO OPTIONS. Max. Unit - The Ira ear ALL :OPTIONS Instated.. Ecartanta=r, etc.) 1,1 di (1191{ BASE END VIEW Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 15 of 18 7 118) 54T. 4143) 4 AA 6•1/4 1 (41.3? (40 BB rrom s I 27) URN AI • arasiiti , ,.. ‘ 25 BOTTOM (505i CENTER 7 SUFPLY ,r OF Fs,. AIN ..,,, "' aRAVIT Y % , ) OPENINC Z540 45-374 IqH.4)012 FF —1 65,8 4-1/2 e-a) \ f2i41) -1 a -le c)c) I ,..__ 1,„_26-1r2 DD icaa 3) BOTTOM CONDENSATE OUTLET BOTTOM POWER ENTRY 3 X E475 X 203) TOP VIEW (Base) 8:1-t 42'1 CONDENSATE 00111:T IEITHER SIDE) • Nt ; 5-tri • 1410) ELECTRICAL. ei-14 ETr65} SASE SIDE VIEW 7) LIPTIN; Hata' ITceriggain9) 11 11111 1 lilh: 11 11 1 I old 111,111 . III '15' \ 100 t 0 0 5) 25 (737) FORKLIFT SLOTS s.1,.2. HORIZONTAL 1-1"ORIZONTAL 5,112 0'r...11, Sack. and (1,40s StIPPLY AR RETURN AIR flA0.? tPi.Vvef: Eirsa ' ,ant411,3C,' OPEN INC 0,41na,-.11Econtgr BACK VIEW Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 Lennox Industries Inc. - Product Submittal System ID: RTU - 6 Package Model: KHB036S4B Description: PKGHP/3TON/BTO OUTDOOR AIR HOOD DETAIL WITH OPTIONAL ECONOMI {Horizontal Applicationsi SUPPLY AIR II/ICJ Fzid Posnkled) SLIPPLY AR TOP VIEW RETURN AIR CULT TRANSITION bbtatiod heakiAd al/14/ 19,1,2 -3/8 095 / #7971 1 i III: II 11111: 111111 I i II III li II 1 I:II 11111 1111111111 I 1"111 Id ill; II I 1111 Div, trading ruA usett ki —Hadzonts, 4352CTIL 07 F. NIN .- T. Atgit9tIcris 2..) Etxviv.I'vr tR081 1 1 —1... I ._ ___, 00 BACK VIEW 51,2 R D BAROMETRIC RELIEF DAMPERS 4ETLIRN AR VALET OUT-MORAN HOOD Ecznerntoe, TURN: AR DirT Fatbetotad ..Mantba iv.t.V.Intninda tit FtalW iittld and Ritttrn ti7,Rowtanniccrec.1, HARGI/ETRIC RELIEF. HOOD DIMENSIONS WI h 912 nim.1, Heikg Et -2 t 633 nyn}(024,, a35, CDC. 049) 25 n_ 1E05 mek 405% 072i Sma Frantatm ;me deitvh. NOTE -,NcriztrtV acqsamifcnr.vt-th Econ.:14=r cmpiAl HavittintilcAttparzinot Cowan:km Mk StI6, 07Jtats,Acce waa vitt tab/a. DAROkIEIRCRE_LiET HOOTJ 0:thieved `' arwrizer and iredRid ftvf.ttiled R,dtrn OUTDOOR AR EXHAUST AIR RETURN AR DUCT TRANSITON VRARI btnclatvi aid fist:gad oftl) «0,,R,MN7AL OPENIWS TURN AR DUCT 1/1. ET Feld Tah.ka - /Aid acaznrrodarto Etro-natA,'m Rain' HoodrIc%atm /1/47Rsq.bits ReteetA Dud Snd Tnt'1 flt1 t*. &IV:Alt/el 7A 4'2-Z 2112 f 5n A 30,701 6 ' 411. —I. 0— 4773:, —10 t Model No. A in. mm 024, 030, 036, 048 .060, 072 Is-ae4 47e 22-112 :572 in. nun 11-3,4 2PS 15-304 400 Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Pagel6 of 18 1-7 00 S.7.7•PA1221M1C7: °FENN:I WM4 .S.:47AMMIMR. MEMkLEED END VIEW Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 Lennox Industries Inc. - Product Submittal System ID: RTU - 6 Package Model: KHB036S4B Description: PKGHP/3TONBTO UNIT CLEARANCES - INCHES (MM) 1 Unit Clearance in. A mm in. B mm__ C mm_ D mm Top Clearance _in. _in. Service Clearance 36 914 36 914 36 934 36 914 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. 1 Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 17 of 18 Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 Lennox Industries Inc. - Product Submittal MISCELLANEOUS MATERIALS EOC Third Party EOC & GUIDED SETUP EOC Third Party EOC & GUIDED SETUP Y3028 BE RTS2 94L60 COSNZNO7AE1- SENSOR, NONADJST TEMP 58W63 C1SNSR75AD1 AIR TEMPERING KIT 54W2I 100929-04 FILTER 20X20X2 - MERV 8 54W20 100929-05 FILTER - MERV 8 16 X 20 X 2 SERVC Third Party NAS INSTALL Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000599928 ROSS # 44 TUKWILA, WA Page 18 of 18 Last Changed: SAM WIESE Prepared On: 2015-09-30 Phone: 972-497-6301 TOP FLANGE DIM: 1 1/2" i L AWN BY.: SLW. H-LCH 156-360 I OLD UNIT:TRANE SACA/SACC/SFCA/SFCB C15/17 ROLLS OF GASKET:2 TAG: RTU-4,5 Note: Desian subiect to chanae without notice. File Name: LX8TR225 LX111TR225 NEW LENNOX L-SERIES 156-360 EXISTING TRANE SFCB SACA Cl2t1Mattbe Blh2A,911CA i .£216b6 3S`d8 oi74Z 1£6 2/1. 8L R£Z ,,£ i- 008/6 X „ ,.61 Q Iry rn r i I I I I IQTY.: 2 DI INEW UNIT:LENN L/T/K-SERIES/LC �` —,' "l ��91 ��L£ J •a•i ��819 LZ .8/9 Z8 - '0 98 0.8/9 CUEBB iP ,UUgq INC. TRANSITION -CURB SYSTEM 1200 Carlene Rd. Confidential and propriety information of Curbs Plus, Inc. unauthorized use, disclosure, or reproduction Is expressly prohibited. Rossville, GA 30741 TAG PLATE:LX8TR225 / LX111TR225 Phone:(706) 858-1188 / Fax: (706) 866-2339 website: www.curbs-plus.com APPROXIMATE WEIGHT:420 LBS. Q a 0 Z Approved By: CLOSURES: 14 GA Q c Z c i o _ N .47l „£ d. Drawing Date: 3-29-05 I REV: 001 PANS:18 GA CHANNELS:14 GA I \ \ \\\_ \ ‘ = \ \ \ CO 101 1/2" O.D. 98 1/2" I.D. U.) 71" BASE - \ ` I SHELL:14 GA vio The Roof Reinforcer STRUCTURAL ANALYSIS REPORT for HVAC REPLACEMENT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 Prepared for Paul Hilaire Lennox NAS toss DRESS FOR LESS Prepared by: Tim McCarthy P.E. Nationwide Roof Reinforcement Services tA&.o 135 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 10996 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 21 2015 City of Tukwila DIVISION RECEIVED CITY OF TUKWILA OCT 1.3 2015 PERMIT CENTER Main (805) 648-8949 Ik(Cr, I 2_ The Roof Reinforcer ROSS Table of Contents Letter to Building Official 2 Scope 3 Site Location Maps 4 Site Aerial Views 5 Calculations 6 to 23 Snow Data 24 Drawings 25 to 27 Photographic Report 28 to 49 Existing Equipment Specifications 50 to 70 New Equipment Submittal 71 to 86 Adaptor Curb 87 to 91 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 Main (805) 648-8949 10996 Page 1 The Roof Reinforcer Building Official Building Division City of Tukwila 6300 Southcenter Blvd. 100 Tukwila, WA 98188 Date: October 7, 2015 Subject: Structural Analysis for HVAC Equipment Replacement RE: Ross 44 - 17672 Southcenter Pkwy, Tukwila, WA 98188 Dear Building Official, Thank you for your time to review this report! We have been retained to provide structural services associated with Ross' plan to replace certain roof top mounted HVAC unit. This report provides an analysis of the vertical load effect of the replacement units on the roof. The lateral hold-down connections are being provided by the contractor. We have received data regarding both the existing and new units and have included it in this report, along with data regarding adaptor curbs. The data is summarized in the table below. We have conducted a structural analysis (please see calculations attached), and have concluded that the structure is adequate to support the proposed loads without reinforcement. Please permit this structure without any further structural analysis required. If additional analysis is required, please advise. I'd be happy to answer any questions you have! RTU NO. Existing HVAC Data New HVAC Data ANALYSIS RTU SIZE MFR Model Number Weight (Total) RTU SIZE MFR Model Number Weight (Total) adaptor curb - 1- ;! I co 3 5 1 5 Trane WCC060F400BB 529 5 Lennox KHA060S4B 796 0 796 267 2 5 Trane WCH060A400BA 602 5 Lennox KHA060S4B 796 0 796 194 4 17 Trane SACC-C174-A 2030 20 Lennox KHA240S4M 2298 420 2718 688 5 17 Trane SACC-C174-A 2030 20 Lennox KHA240S4M 2298 420 2718 688 6 2.5 Trane SAHB-B256-A 445 3 Lennox KHA036S4D 720 0 720 275 7 5 Lennox CHP16-653-9G 521 5 Lennox KHA060S4B 796 0 796 275 Timothy P. McCkrthy, P.E. Principal www.T h eRo ofRe i n fo rcer. co m 434 E. Main Street B, Ventura, CA 93001 10996 Main (805) 648-8949 ;2 The Roof Reinforcer SCOPE This report, and any associated plans and calculations, have been developed for the sole purpose of assessing the adequacy of the roof structure at the address listed to support specific new roof mounted HVAC equipment listed within this report under gravity loads. Where included in this report, lateral load connections to curbs above the roof have been provided as a courtesy to the client. These connections may be safely used if the equipment suppliers or the curb suppliers or the installation contractors have not provided alternative properly engineered connections. Investigation, analysis and design of seismic bracing or connections of either new or existing HVAC accoutrements such as ducting have not been requested by the client and are not included in the scope of this report. Should assistance with these items be desired, please contact the preparer of this report and we will provide you with appropriate and professional guidance. THE USE OF THIS REPORT This report is for the exclusive use of our client and for the sole purpose for which it was created. Other persons or companies or subsequent tenants or subsequent owners should not rely upon any portion of this report for any other purposes. Should others persons or companies be interested in any item in this report, they are invited to contact the preparer and we will provide you with appropriate and professional guidance. SITE VISIT The companying issuing this report has performed a site visit. The site visit was for the purpose of the scope described above and for no other purpose. The site visit did not include any observations or investigations beyond what was useful for this precise scope. The site visit obtained general data on the basic roof framing system and certain specific data on certain typical roof structure elements supporting the equipment to be replaced. The data may be represented in this report as approximations and therefore no data, such as dimensions, should be relied upon by any other trade or professional without additional confirmation. The site visit shall not be construed as acceptance by an engineer of any defects or deficiencies or damages that may or may not exist in the structure. DISCLAIMER This report is not an exhaustive structural assessment of the structure as a whole, nor of any parts of the structure. The report relies upon presuppositions that are generally understood in the engineering community. Such presuppositions include that the building and any subsequent modifications were properly designed and permitted; and that the materials used were properly graded and constructed. Therefore a minute inspection was not performed and no destructive testing was performed. This report therefore may not be deemed in any way at all as warrantee that the building as a whole or any of its parts are structurally sound for any other purpose. Specifically this report shall not be used or relied upon in the selling or purchasing or financing or leasing or insuring of the building. If such occasions arise, such persons are welcome to contact the preparer and we will do our best to provide you with appropriate and professional guidance. www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 Main (805) 648-8949 Page 3 The Roof Reinforcer Jo -Ann rahric and Craft 6 royo Jo/Babies'R'us STRUCTURAL ANALYSIS REPORT for HVAC REPLACEMENT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 Attece Meaicm Restaurants Ashley rurntlure NonxStore Winners v roprese - Soulh Center Mall a3M.! ei.a Atho trendy footwear 6 accesaorxa retake SITE LOCATION MAP tl Michaels d Spnra Store Suons Auttwmy sporurg Goods N 0 it Old Nary Starbucks campus Da'x s Bat -B Due e I ?Ross Dress for Less Dtscouapparel. 00 shoes & housewares O Cost Plus World Market CI David's Nodal SITE LOCATION MAP f:] www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 Main (805) 648-8949 I0996 Page 4 The Roof Reinforcer STRUCTURAL ANALYSIS REPORT for HVAC REPLACEMENT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 AERIAL VIEW AERIAL VIEW Main (805) 648-8949 10996 Page 5 BEAM ANALYSIS SIMPLE SPAN FOR VERTICAL LOADS JOB NUMBER 110996 JOB NAME Ross 44 ADDRESS 17672 SOUTHCENTER PKWY ADDRESS TUKWILA WA SPAN 201FT 0`IN SPACING 8FT OIIN Live Load 20PSF 20.0 Snow Load pg 251PSF 25 Dead Load 201PSF EXISTING LOADING CONDITIONS (Reduced LL) (0.7 x 1.0 x 1.0 x RTU I EXIST I % NEW % [... 11 5291 33% 174.6 796 33% 262.7 11 5291 33% 174.6 796 33% 262.7 1.0 x p jam`----- 1 0% 0 0% 0 0% 0 0% 0 POINT LOADS MAGNITUDE case 11 DL 21 DL 31 4m. 1 6... 71 1,,, 174.6ILBS 174.61 LBS OILBS OILBS ALBS :LBS LBS LOCATION FROM LEFT END 13FT 1 511N IP 161FT I LIN FT mmIN ..m.....m I.....................f IFT I IIN i !IN �IFT 1IN COMMENTS RTU 1- Purlin UNIFORM LOADS MAGNITUDE case 1 LL 2 SL 3 DL 4 5. 6 _..m 7 160 PLF 200 PLF 160 PLF PLF IPLF ...._mmmmm4PLF I▪ PLF NEW LOADING CONDITIONS LOCATION FROM LEFT END START POINT O FT 0 IN O FT 0 IN O FT 0 IN 11N LFT g......._..........11N IFT 1 !IN FT i 1IN €FT END POINT 20 FT 20 FT 20 FT FT mmmmmm FT mm...._m. FT ,FT 0 0 0 COMMENTS POINT LOADS MAGNITUDE case 11 DL 262.7LBS 4- 21 DL 262.7LBS 31 OILBS 4` 0=LBS 51 1LBS 6 ;LBS 1 1.. ,,.mm.........,.,.m..m. 71 `LBS LOCATION FROM LEFT END 131FT 5 1N 16IFT 111N OIFT O.IN m.mmm 0I FT 6m mm m.m0 1 N FT IIN IFT iIN FT IN COMMENTS UNIFORM LOADS MAGNITUDE case 1 LL 160 PLF 2 SL 200 PLF 3 DL 160 PLF 41 IPLF 53.........,..,.........._....... PLF 61 IPLF IPLF LOCATION FROM LEFT END START POINT O FT O FT 0 FT FT FT FT FT 0 0 0 IN IN IN IN IN IN END POINT 20 FT 20 FT 20 FT FT FT .........m_. FT FT 0 0 0 COMMENTS Page 6 JOB NAME 110996 JOB NUMBER :Ross44 ADDRESS :17672 SOUTHCENTER PKWY ADDRESS iTUKWILA WA - STRESSES UNDER EXISTING LOADING CONDITIONS SHEAR LEFT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL SHEAR 1691.6 LBS RIGHT 1600.0 LBS 2000.0 LBS 0.0 LBS 0.0 LBS 3291.6 LBS 3691.6 LBS 1691.6 LBS 1691.6 LBS DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL MOMENT 1857.5 LBS DL 1600.0 LBS LL 2000.0 LBS SL 0.0 LBS EQ 0.0 LBS WL 3457.5 LBS DL+LL 3857.5 LBS DL+SL 1857.5 LBS DL+EQ 1857.5 LBS DL+WL 8942.7 FT-LBS 8000.0 FT-LBS 10000.0 FT-LBS 0.0 FT-LBS 0.0 FT-LBS 16929.6 FT-LBS 18928.2 FT-LBS 8942.7 FT-LBS 8942.7 FT-LBS STRESSES UNDER NEW LOADING CONDITIONS SHEAR SHEAR LEFT DL 1737.9 LBS RIGHT LL 1600.0 LBS SL 2000.0 LBS EQ 0.0 LBS WL 0.0 LBS DL+LL 3337.9 LBS DL+SL 3737.9 LBS DL+EQ 1737.9 LBS DI+WL 1737.9 LBS DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL 1987.5 LBS 1600.0 LBS 2000.0 LBS 0.0 LBS 0.0 LBS 3587.5 LBS 3987.5 LBS 1987.5 LBS 1987.5 LBS MOMENT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL 9438.5 FT-LBS 8000.0 FT-LBS 10000.0 FT-LBS 0.0 FT-LBS 0.0 FT-LBS 17408.8 FT-LBS 19405.5 FT-LBS 9438.5 FT-LBS 9438.5 FT-LBS MAXIMUM EXISTING STRESSES SHEAR LEFT SHEAR RIGHT MOMENT ALLOWABLE PER IBC SHEAR LEFT SHEAR RIGHT MOMENT 3691.6 LBS 3857.5 LBS 18928.2 FT-LBS 5% INCREASE 3876.2 LBS 4050.4 LBS 19874.6 FT-LBS MAXIMUM NEW STRESSES > SHEAR LEFT > SHEAR RIGHT > MOMENT 3737.9 LBS OK 3987.5 LBS OK 19405.5 FT-LBS OK Page 7 BEAM ANALYSIS ---- SIMPLE SPAN FOR VERTICAL LOADS SPAN 201FT 0-IN SPACING 8`FT 0 IN Live Load 20PSF 1 20.0 Snow Load PR 25`PSF 25 Dead Load I 20IPSF EXISTING LOADING CONDITIONS (Reduced LL) (0.7x1.0x1.0x JOB NUMBER 110996 JOB NAME Ross 44 ADDRESS 17672 SOUTHCENTER PKWY ADDRESS TUKWILA WA RTU J EXIST I % NEW % 21 6021 33% 198.7 796 33% 262.7 21 602 33% 198.7 796 33% 262.7 1.0 x pa)I 1 0% 0 0% 0 I t ( I 0% 0 0% 0 POINT LOADS case 11 DL 2I DL 31 4= 51 MAGNITUDE 198.7'LBS 198.7(LBS 0ILBS OILBS ILBS 6( 7( (LBS 4LBS LOCATION FROM LEFT END 141FT i SIIN 171FT ; — 5 IN (FT i IIN AFT : IIN (FT 1 .IN (FT 1 IIN (FT ; (IN COMMENTS RTU 2 - Purlin UNIFORM LOADS MAGNITUDE case 1 LL 2 SL 3 DL 4 5 6 7 160 PLF 200 PLF 160 PLF (PLF —IPLF (PLF PLF LOCATION FROM LEFT END START POINT O FT O FT O FT IFT EFT (FT IFT 0 0 0 IN IN IN IN IN IN IN END POINT 20 FT 20 FT 20 FT FT FT FT FT 0 0 0 COMMENTS NEW LOADING CONDITIONS POINT LOADS case 11 DL 21 DL 4 6 7 MAGNITUDE 262.71LBS 262.7!LBS OILBS 0(LBS 1LBS ILBS (LBS LOCATION FROM LEFT END 14(FT 5 IN 17;FT i 5'IN 0'FT O(IN OFT 0 IN IFT IIN £FT •IIN IFT ! (IN COMMENTS UNIFORM LOADS 1 2 3 4L 51 6 7 MAGNITUDE case LL 160 SL 200 DL 160 PLF PLF PLF =PLF PLF PLF PLF LOCATION FROM LEFT END START POINT O FT O FT O FT (FT (FT 'FT IFT 0 0 0 IN IN IN (IN IIN 'IN IIN END POINT 20 FT 20 FT 20 FT FT FT FT FT 0 0 0 IN IN IN IN IN .IN IN COMMENTS Page 8 JOB NAME 110996 JOB NUMBER 1Ross44 ADDRESS 117672 SOUTHCENTER PKWY ADDRESS TUKWILA WA - STRESSES UNDER EXISTING LOADING CONDITIONS SHEAR LEFT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL SHEAR 1681.1 LBS RIGHT 1600.0 LBS 2000.0 LBS 0.0 LBS 0.0 LBS 3281.1 LBS 3681.1 LBS 1681.1 LBS 1681.1 LBS DL 1916.2 LBS LL 1600.0 LBS SL 2000.0 LBS EQ 0.0 LBS WL 0.0 LBS DL+LL 3516.2 LBS DL+SL 3916.2 LBS DL+EQ 1916.2 LBS DL+W L 1916.2 LBS MOMENT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL 8831.8 FT-LBS 8000.0 FT-LBS 10000.0 FT-LBS 0.0 FT-LBS 0.0 FT-LBS 16821.5 FT-LBS 18820.3 FT-LBS 8831.8 FT-LBS 8831.8 FT-LBS STRESSES UNDER NEW LOADING CONDITIONS SHEAR SHEAR LEFT DL 1707.3 LBS RIGHT LL 1600.0 LBS SL 2000.0 LBS EQ 0.0 LBS WL 0.0 LBS DL+LL 3307.3 LBS DL+SL 3707.3 LBS DL+EQ 1707.3 LBS DL+WL 1707.3 LBS DL 2018.1 LBS LL 1600.0 LBS SL 2000.0 LBS EQ 0.0 LBS WL 0.0 LBS DL+LL 3618.1 LBS DL+SL 4018.1 LBS DL+EQ 2018.1 LBS DL+WL 2018.1 LBS MOMENT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL 9108.6 FT-LBS 8000.0 FT-LBS 10000.0 FT-LBS 0.0 FT-LBS 0.0 FT-LBS 17090.6 FT-LBS 19088.6 FT-LBS 9108.6 FT-LBS 9108.6 FT-LBS MAXIMUM EXISTING STRESSES SHEAR LEFT SHEAR RIGHT MOMENT ALLOWABLE PER IBC SHEAR LEFT SHEAR RIGHT MOMENT 3681.1 LBS 3916.2 LBS 18820.3 FT-LBS 5% INCREASE 3865.2 LBS 4112.0 LBS 19761.3 FT-LBS MAXIMUM NEW STRESSES SHEAR LEFT SHEAR RIGHT MOMENT 3707.3 LBS OK 4018.1 LBS OK 19088.6 FT-LBS OK Page 9 BEAM ANALYSIS --- SIMPLE SPAN FOR VERTICAL LOADS SPAN 20IFT 0 IN SPACING 6IFT 10.5:IN Live Load Snow Load Pg Dead Load 20IPSF 251PSF 20(PSF EXISTING LOADING CONDITIONS 20.0 (Reduced LL) 25 (0.7 x 1.0 x 1.0 x JOB NUMBER I10996 JOB NAME Ross44 ADDRESS 17672 SOUTHCENTER PKWY ADDRESS TUKWILA WA RTU I EXIST I % NEW % 41. 2030125% [ 507.5 2718 25% 679.5 0% 0 0% 0 1.0 x pg)1 I 0% 0 0% 0 0% 0 ' 0% 0 POINT LOADS MAGNITUDE case 11 DL 2€ DL 3t 41 SI 6 7 507.5ILBS OILBS OALBS 5 0ILBS ¢LBS LBS ILBS UNIFORM LOADS 1 2 3 4 5 6 7 LOCATION FROM LEFT END 13IFT 51IN 0IFT 0€IN €FT } 11N FT 1 IIN IFT ! 11N IN IN FT IFT COMMENTS RTU 4 - Purlin MAGNITUDE case LL 137.5 SL 171.9 DL 137.5 PLF PLF PLF IPLF IPLF ;PLF 'PLF LOCATION FROM LEFT END START POINT O FT O FT O FT FT IFT IFT €FT 0 0 0 IN IN IN IN IN IN IN END POINT 20 FT 0 IN 20 FT 0 IN 20 FT 0 IN IFT IIN IFT• i JIN JFT 1, IN IFT FIN COMMENTS NEW LOADING CONDITIONS POINT LOADS case 1 DL 2 DL 31 41 5 MAGNITUDE 679.51LBS OILBS O1LBS OILBS ;LBS 6€ ILBS 7I ;LBS LOCATION FROM LEFT END 13IFT 5 IN OIFT 1 0#IN 01FT i 011N OF FT SIN FT IIN IFT ' IN mm� a EFT IN COMMENTS UNIFORM LOADS 1 2 3 4 5 6 7 MAGNITUDE case LL SL DL 137.5 PLF 171.9 PLF 137.5 PLF -PLF PLF PLF PLF LOCATION FROM LEFT END START POINT 0 FT O FT O FT FT jFT IFT --1 FT 0 0 0 END POINT IN 20 FT 0 IN IN 20 FT 0 IN IN 20 FT 0 IN IN FT IIN IN FT IN IN FT IIN IN FT 1 /IN COMMENTS Page 10 JOB NAME 110996 JOB NUMBER i Ross44 ADDRESS `17672 SOUTHCENTER PKWY ADDRESS !TUKWILA WA STRESSES UNDER EXISTING LOADING CONDITIONS SHEAR LEFT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL SHEAR 1542.1 LBS RIGHT 1375.0 LBS 1718.8 LBS 0.0 LBS 0.0 LBS 2917.1 LBS 3260.8 LBS 1542.1 LBS 1542.1 LBS DL 1715.4 LBS LL 1375.0 LBS SL 1718.8 LBS EQ 0.0 LBS WL 0.0 LBS DL+LL 3090.4 LBS DL+SL 3434.2 LBS DL+EQ 1715.4 LBS DL+WL 1715.4 LBS MOMENT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL 8647.0 FT-LBS 6875.0 FT-LBS 8593.8 FT-LBS 0.0 FT-LBS 0.0 FT-LBS 15471.3 FT-LBS 17184.4 FT-LBS 8647.0 FT-LBS 8647.0 FT-LBS STRESSES UNDER NEW LOADING CONDITIONS SHEAR SHEAR LEFT DL 1598.7 LBS RIGHT LL 1375.0 LBS SL 1718.8 LBS EQ 0.0 LBS WL 0.0 LBS DL+LL 2973.7 LBS DL+SL 3317.4 LBS DL+EQ 1598.7 LBS DL+WL 1598.7 LBS DL 1830.8 LBS LL 1375.0 LBS SL 1718.8 LBS EQ 0.0 LBS WL 0.0 LBS DL+LL 3205.8 LBS DL+SL 3549.6 LBS DL+EQ 1830.8 LBS DL+WL 1830.8 LBS MOMENT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL 9293.6 FT-LBS 6875.0 FT-LBS 8593.8 FT-LBS 0.0 FT-LBS 0.0 FT-LBS 16077.6 FT-LBS 17786.3 FT-LBS 9293.6 FT-LBS 9293.6 FT-LBS MAXIMUM EXISTING STRESSES SHEAR LEFT SHEAR RIGHT MOMENT ALLOWABLE PER IBC SHEAR LEFT SHEAR RIGHT MOMENT 3260.8 LBS 3434.2 LBS 17184.4 FT-LBS 5% INCREASE 3423.8 LBS 3605.9 LBS 18043.6 FT-LBS MAXIMUM NEW STRESSES > SHEAR LEFT SHEAR RIGHT MOMENT 3317.4 LBS OK 3549.6 LBS OK 17786.3 FT-LBS OK Page 11 BEAM ANALYSIS SIMPLE SPAN FOR VERTICAL LOADS JOB NUMBER €10996 20IFT SPACING E 6IFT I 10.5 IN 20IPSF SPAN Live Load 0EIN 20.0 Snow Load pg 251PSF Dead Load 1 20PSF EXISTING LOADING CONDITION 25 (Reduced LL) (0.7 x 1.0 x 1.0 x JOB NAME Ross 44 ADDRESS 17672 SOUTHCENTER PKWY ADDRESS TUKWILA WA RTU I EXIST I % NEW % 51 2030 33% 669.9 2718 33% 896.9 = 0% 0 0% 0 1.0xp�)1 I 0% 0 0% 0 i ! 0% 0 0% 0 POINT LOADS MAGNITUDE case 1€ DI. 669.9!LBS 21 DL OILBS 3 OILBS 4! OILBS 5€ ILBS 61 ILBS 71 =LBS LOCATION FROM LEFT END 13IFT 1 9tIN 0 FT to 0 IN IFT IIN _)....e®_FT 11IN IFT [ IIN EFT IIN IFT i IN COMMENTS RTU 5 - Purlin UNIFORM LOADS 1 2 3 4 6 MAGNITUDE case LL 137.5 SL 171.9 DL 137.5 71 PLF PLF PLF PLF _PLF !PLF 1PLF NEW LOADING CONDITIONS LOCATION FROM LEFT END START POINT FT FT FT FT FT FT )FT 0 0 0 POINT COMMENTS IN IN IN FT IN FT FT IN FT IN POINT LOADS case 1( DL 2I DL 31 41 5I 61 71 MAGNITUDE 896.9LBS OLBS OILBS OILBS ILBS ;LBS ?LBS LOCATION FROM LEFT END 13IFTIN OIFT 0IIN GIFT O IN GIFT 0!IN IFT IIN FT !1N IFT /IN COMMENTS UNIFORM LOAD case 1 LL 2 SL 3 4 5 6 71 DL S MAGNITUDE 137.5 PLF 171.9 PLF 137.5 PLF .PLF ;PLF 1PLF EPLF LOCATION FROM LEFT END START POINT O FT 0 IN O FT 0 IN O FT 0 IN FT IIN FT IN FT IN IFT !IN END POINT 20 FT 0 IN 20 FT 0 IN 20 FT 0 IN -FT !IN v� FT IIN FT IIN FT - /IN COMMENTS Page 12 JOB NAME 110996 JOB NUMBER Ross44 ADDRESS 117672 SOUTHCENTER PKWY ADDRESS 'TUKWILA WA STRESSES UNDER EXISTING LOADING CONDITIONS SHEAR LEFT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL SHEAR 1584.3 LBS RIGHT 1375.0 LBS 1718.8 LBS 0.0 LBS 0.0 LBS 2959.3 LBS 3303.1 LBS 1584.3 LBS 1584.3 LBS DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL MOMENT 1835.6 LBS DL 1375.0 LBS LL 1718.8 LBS SL 0.0 LBS EQ 0.0 LBS WL 3210.6 LBS DL+LL 3554.3 LBS DL+SL 1835.6 LBS DL+EQ 1835.6 LBS DL+WL 9127.8 FT-LBS 6875.0 FT-LBS 8593.8 FT-LBS 0.0 FT-LBS 0.0 FT-LBS 15923.1 FT-LBS 17633.0 FT-LBS 9127.8 FT-LBS 9127.8 FT-LBS STRESSES UNDER NEW LOADING CONDITIONS SHEAR SHEAR LEFT DL 1655.3 LBS RIGHT LL 1375.0 LBS SL 1718.8 LBS EQ 0.0 LBS WL 0.0 LBS DL+LL 3030.3 LBS DL+SL 3374.0 LBS DL+EQ 1655.3 LBS DL+WL 1655.3 LBS DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL 1991.6 LBS 1375.0 LBS 1718.8 LBS 0.0 LBS 0.0 LBS 3366.6 LBS 3710.4 LBS 1991.6 LBS 1991.6 LBS MOMENT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL 9963.6 FT-LBS 6875.0 FT-LBS 8593.8 FT-LBS 0.0 FT-LBS 0.0 FT-LBS 16695.8 FT-LBS 18398.7 FT-LBS 9963.6 FT-LBS 9963.6 FT-LBS MAXIMUM EXISTING STRESSES SHEAR LEFT SHEAR RIGHT MOMENT ALLOWABLE PER IBC SHEAR LEFT SHEAR RIGHT MOMENT 3303.1 LBS 3554.3 LBS 17633.0 FT-LBS 5% INCREASE 3468.2 LBS 3732.0 LBS 18514.7 FT-LBS MAXIMUM NEW STRESSES > SHEAR LEFT > SHEAR RIGHT > MOMENT 3374.0 LBS OK 3710.4 LBS OK 18398.7 FT-LBS OK Page 13 BEAM ANALYSIS SIMPLE SPAN FOR VERTICAL LOADS JOB NUMBER 110996 JOB NAME Ross 44 ADDRESS 17672 SOUTHCENTER PKWY ADDRESS TUKWILA WA SPAN 20$FT OIIN SPACING 81FT OIIN Live Load I 20=PSF 20.0 Snow Load pA 25IPSF Dead Load ( 201PSF EXISTING LOADING CONDITION 25 (Reduced LL) (0.7 x 1.0 x 1.0 x RTU I EXIST I % NEW % 6. 4451 33% 146.9 720 33% 237.6 6 4451 33% 146.9 720 33% 237.6 1.0 x ps) 1 0% 0 0% 0 f 0% 0 O% 0 POINT LOADS MAGNITUDE case 11 DL 146.9 LBS 21 DL 146.91LBS 31 0LBS 41 OILBS 51 6( 7 .LBS LBS ALBS LOCATION FROM LEFT END OIFT SIN 7=FT } 81IN FT :IN IFT i I N -1FT €.IN FT IN FT ; IIN COMMENTS RTU 6 - Purlin UNIFORM LOADS 1 2 3 4 6 MAGNITUDE case LL 160 PLF SL 200 PLF DL 160 PLF PLF PLF PLF PLF NEW LOADING CONDITIONS LOCATION FROM LEFT END START POINT O FT O FT O FT FT FT F IT 0 0 0 END POINT 20 FT 0 IN 20 FT 0 IN 20 FT 0 IN FT 1IN FT 1IN IFT �IN FT yIN COMMENTS POINT LOADS case 1 DL 2; DL 31 4 5 6= 7 MAGNITUDE 237.61LBS 237.6 LBS 0 LBS OSLBS LBS ]LBS LBS LOCATION FROM LEFT END GIFT 91IN 7 FT� IN 0IFT ( 0'IN O=FT� �IN €FT ; IN IFT IN IFT i IN COMMENTS UNIFORM LOADS 1 2 3 4 6 7 MAGNITUDE case LL 160 SL 200 DL 160 PLF PLF PLF PLF PLF PLF PLF LOCATION FROM LEFT END START POINT O FT O FT 0 FT .FT FT FT FT IN IN IN IN IN 1IN IIN END POINT 20 FT 20 FT 20 FT IFT IFT IFT FT 0 0 0 IN IN IN IN IN IN /IN COMMENTS Page 19 JOB NAME 110996 JOB NUMBER 'Ross 44 ADDRESS 117672 SOUTHCENTER PKWY ADDRESS !TUKWILA WA STRESSES UNDER EXISTING LOADING CONDITIONS SHEAR LEFT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL SHEAR 1831.9 LBS RIGHT 1600.0 LBS 2000.0 LBS 0.0 LBS 0.0 LBS 3431.9 LBS 3831.9 LBS 1831.9 LBS 1831.9 LBS DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL MOMENT 1661.8 LBS DL 1600.0 LBS LL 2000.0 LBS SL 0.0 LBS EQ 0.0 LBS WL 3261.8 LBS DL+LL 3661.8 LBS DL+SL 1661.8 LBS DL+EQ 1661.8 LBS DL+WL 8624.5 FT-LBS 8000.0 FT-LBS 10000.0 FT-LBS 0.0 FT-LBS 0.0 FT-LBS 16618.6 FT-LBS 18617.9 FT-LBS 8624.5 FT-LBS 8624.5 FT-LBS STRESSES UNDER NEW LOADING CONDITIONS SHEAR SHEAR LEFT DL 1975.2 LBS RIGHT LL 1600.0 LBS SL 2000.0 LBS EQ 0.0 LBS WL 0.0 LBS DL+LL 3575.2 LBS DL+SL 3975.2 LBS DL+EQ 1975.2 LBS DL+WL 1975.2 LBS DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL 1700.0 LBS 1600.0 LBS 2000.0 LBS 0.0 LBS 0.0 LBS 3300.0 LBS 3700.0 LBS 1700.0 LBS 1700.0 LBS MOMENT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL 9022.4 FT-LBS 8000.0 FT-LBS 10000.0 FT-LBS 0.0 FT-LBS 0.0 FT-LBS 17006.8 FT-LBS 19005.1 FT-LBS 9022.4 FT-LBS 9022.4 FT-LBS MAXIMUM EXISTING STRESSES SHEAR LEFT SHEAR RIGHT MOMENT ALLOWABLE PER IBC SHEAR LEFT SHEAR RIGHT MOMENT 3831.9 LBS 3661.8 LBS 18617.9 FT-LBS 5% INCREASE 4023.5 LBS 3844.9 LBS 19548.8 FT-LBS MAXIMUM NEW STRESSES SHEAR LEFT > SHEAR RIGHT > MOMENT 3975.2 LBS OK 3700.0 LBS OK 19005.1 FT-LBS OK Page 15 4 51 61 BEAM ANALYSIS ---- SIMPLE SPAN FOR VERTICAL LOADS JOB NUMBER 110996 SPAN 20iFT 011N SPACING SIFT 011N Live Load 201PSF 20.0 Snow Load pg Dead Load 25!PSF 201PSF EXISTING LOADING CONDITIONS 25 (Reduced LL) (0.7 x 1.0 x 1.0 x JOB NAME Ross 44 ADDRESS 17672 SOUTHCENTER PKWY ADDRESS TUKWILA WA RTU I EXIST 1 % NEW % 71 5211 33% _ 171.9 796 33% 262.7 0% 0 0% 0 1.0xpg)I 1 0% 0 0% 0 1 0% 0 0% 0 POINT LOADS MAGNITUDE case 11 DL 2 DL 31 171.91LBS 0 LBS OLBS 01LBS LBS ,LBS 1LBS LOCATION FROM LEFT END 17 FT 1 BEIN O FT j 01IN ;FT ! IN FT 1 11N IFT IIN !FT 1 IIN IFT 1 IIN COMMENTS RTU 7 - Purlin UNIFORM LOADS 1 2 3 4= 5r MAGNITUDE case LL 160 SL 200 DL 160 6 71 PLF PLF PLF PLF PLF PLF PLF NEW LOADING CONDITIONS LOCATION FROM LEFT END START POINT 0 FT 0 IN O FT 0 IN 0 FT 0 IN FT IIN FT 11N FT IN ,IN FT END POINT 20 FT 20 FT 20 FT FT FT FT FT 0 0 0 IN IN IN IN IN IN IN COMMENTS POINT LOADS MAGNITUDE case 1 DL 21 DL 31 4 51 61 71 262.7JLBS 01LBS O:LBS 01LBS 1LBS 1LBS 1LBS LOCATION FROM LEFT END 17IFT 81IN O,FT 0 IN Of FT 01IN O FT 01IN FT 1IN EFT IIN ,FT IIN COMMENTS UNIFORM LOADS MAGNITUDE case 1 LL 2 SL 3 DL 4 5€ 6 7E 160 PLF 200 PLF 160 PLF PLF PLF PLF PLF LOCATION FROM LEFT END START POINT O FT 0 FT O FT FT FT 2 FT FT 0 0 0 END POINT 20 FT 20 FT 20 FT .FT EFT IFT FT COMMENTS Page 16 JOB NAME 110996 JOB NUMBER Ross44 ADDRESS 117672 SOUTHCENTER PKWY ADDRESS =TUKWILA WA STRESSES UNDER EXISTING LOADING CONDITIONS SHEAR LEFT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL SHEAR 1620.1 LBS RIGHT DL 1600.0 LBS LL 2000.0 LBS SL 0.0 LBS EQ 0.0 LBS WL 3220.1 LBS DL+LL 3620.1 LBS DL+SL 1620.1 LBS DL+EQ 1620.1 LBS DL+WL MOMENT 1751.9 LBS DL 1600.0 LBS LL 2000.0 LBS SL 0.0 LBS EQ 0.0 LBS WL 3351.9 LBS DL+LL 3751.9 LBS DL+SL 1751.9 LBS DL+EQ 1751.9 LBS DL+WL 8201.8 FT-LBS 8000.0 FT-LBS 10000.0 FT-LBS 0.0 FT-LBS 0.0 FT-LBS 16201.2 FT-LBS 18201.1 FT-LBS 8201.8 FT-LBS 8201.8 FT-LBS STRESSES UNDER NEW LOADING CONDITIONS SHEAR SHEAR MOMENT LEFT DL 1630.6 LBS RIGHT DL 1832.0 LBS DL 8309.4 FT-LBS LL 1600.0 LBS LL 1600.0 LBS LL 8000.0 FT-LBS SL 2000.0 LBS SL 2000.0 LBS SL 10000.0 FT-LBS EQ 0.0 LBS EQ 0.0 LBS EQ 0.0 FT-LBS WL 0.0 LBS WL 0.0 LBS WL 0.0 FT-LBS DL+LL 3230.6 LBS DL+LL 3432.0 LBS DL+LL 16307.9 FT-LBS DL+SL 3630.6 LBS DL+SL 3832.0 LBS DL+SL 18307.8 FT-LBS DL+EQ 1630.6 LBS DL+EQ 1832.0 LBS DL+EQ 8309.4 FT-LBS DL+WL 1630.6 LBS DL+WL 1832.0 LBS DL+WL 8309.4 FT-LBS MAXIMUM EXISTING STRESSES SHEAR LEFT 3620.1 LBS SHEAR RIGHT 3751.9 LBS MOMENT 18201.1 FT-LBS ALLOWABLE PER IBC 5% INCREASE MAXIMUM NEW STRESSES SHEAR LEFT 3801.1 LBS > SHEAR LEFT 3630.6 LBS OK SHEAR RIGHT 3939.5 LBS SHEAR RIGHT 3832.0 LBS OK MOMENT 19111.2 FT-LBS > MOMENT 18307.8 FT-LBS OK Page 17 BEAM ANALYSIS — SIMPLE SPAN FOR VERTICAL LOADS SPAN 60 FT 0 IN SPACING 20jFT 20IPSF Live Load 0 IN 12.0 Snow Load pg 25PSF 25 Dead Load 20IPSF EXISTING LOADING CONDITIONS (Reduced LL) (0.7 x 1.0 x 1.0 x JOB NUMBER 110996 JOB NAME Ross 44 ADDRESS 17672 SOUTHCENTER PKWY ADDRESS TUKWILA WA RTU I EXIST 1 % NEW % 7 5211 67% 349.1 796 67% 533.3 71 5211 67% 349.1 796 67% 533.3 1.0xp)= d 0% 0 0% 0 1 0% 0 0% 0 POINT LOADS MAGNITUDE case 11 DL 2€ DL 31 41 51 61 7! 349.11LBS 349.11LBS OILBS ,LBS ,LBS LBS LBS LOCATION FROM LEFT END 241FT 1 O1IN 32 FT O IN 1FT i 'IN FT 1 IIN i0 IIN [FT °IN 1FT 1 !IN COMMENTS RTU 7-Girder UNIFORM LOADS MAGNITUDE case 1 LL 240 PLF 2 SL 500 PLF 3 DL 400 PLF PLF 51 PLF 61 PLF 7E PLF LOCATION FROM LEFT END START POINT 0 FT O FT O FT I.FT FT 1FT EFT 0 0 0 END POINT IN 60 FT IN 60 FT IN 60 FT !IN €FT IIN FT IIN IIN ��—FT FT 0 0 0 IN IN IN IN IN IN IN COMMENTS NEW LOADING CONDITIONS POINT LOADS MAGNITUDE LOCATION FROM LEFT END case 1 DL 533.3ILBS 241FT � (PIN 21 DL 533.3 LBS 32-FT ; O IN 31 0 LBS OFT • 0[IN 41 0 LBS OFT 0 IN SE LBS 1FT 1 ?IN 64 1LBS FT ' IN 71 LBS 1FT I [IN UNIFORM LOADS 1 2 3 41 case COMMENTS MAGNITUDE LL 240 SL 500 DL 400 S 6s 71 PLF PLF PLF PLF I PLF 1PLF PLF LOCATION FROM LEFT END START POINT O FT 0 IN O FT 0 IN O FT 0 IN FT IIN FT IIN FT SIN '€FT - [IN END POINT 60 FT 60 FT 60 FT FT FT FT FT 0 0 0 IN IN IN IN IN IN IN COMMENTS Page 18 JOB NAME 110996 JOB NUMBER !Ross44._�a®_ ADDRESS 117672 SOUTHCENTER PKWY ADDRESS TUKWILA WA STRESSES UNDER EXISTING LOADING CONDITIONS SHEAR LEFT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL SHEAR 12372.3 LBS RIGHT 7200.0 LBS 15000.0 LBS 0.0 LBS 0.0 LBS 19572.3 LBS 27372.3 LBS 12372.3 LBS 12372.3 LBS DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL MOMENT 12325.8 LBS DL 7200.0 LBS LL 15000.0 LBS SL 0.0 LBS EQ 0.0 LBS WL 19525.8 LBS DL+LL 27325.8 LBS DL+SL 12325.8 LBS DL+EQ 12325.8 LBS DL+WL 189066.0 FT-LBS 108000.0 FT-LBS 225000.0 FT-LBS 0.0 FT-LBS 0.0 FT-LBS 297065.6 FT-LBS 414065.3 FT-LBS 189066.0 FT-LBS 189066.0 FT-LBS STRESSES UNDER NEW LOADING CONDITIONS SHEAR SHEAR LEFT DL 12568.9 LBS RIGHT LL 7200.0 LBS SL 15000.0 LBS EQ 0.0 LBS WL 0.0 LBS DL+LL 19768.9 LBS DL+SL 27568.9 LBS DL+EQ 12568.9 LBS DL+WL 12568.9 LBS DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL 12497.8 LBS 7200.0 LBS 15000.0 LBS 0.0 LBS 0.0 LBS 19697.8 LBS 27497.8 LBS 12497.8 LBS 12497.8 LBS MOMENT DL LL SL EQ WL DL+LL DL+SL DL+EQ DL+WL 193851.7 FT-LBS 108000.0 FT-LBS 225000.0 FT-LBS 0.0 FT-LBS 0.0 FT-LBS 301851.3 FT-LBS 418850.8 FT-LBS 193851.7 FT-LBS 193851.7 FT-LBS MAXIMUM EXISTING STRESSES SHEAR LEFT 27372.3 LBS SHEAR RIGHT 27325.8 LBS MOMENT 414065.3 FT-LBS ALLOWABLE PER IBC SHEAR LEFT SHEAR RIGHT MOMENT 5% INCREASE 28741.0 LBS 28692.1 LBS 434768.6 FT-LBS MAXIMUM NEW STRESSES > SHEAR LEFT > SHEAR RIGHT > MOMENT 27568.9 LBS OK 27497.8 LBS OK 418850.8 FT-LBS OK Page 19 The Roof Reinforcer ;_ .Cnomneni,Shear Berne no 1o.fficn b . _. _ _..bernna net Cs‘ ') Cpt .) . tic www.TheRoofReinforeer.com 434 E. Main Street B, Ventura, CA 93001 tSoo 115 Ross. _ -ukw►ta., t A precb ; tofig _r✓ lloworb�_er Conclusion She,L.r —w cpt� Zz5._'._ • zz s .___._. ok Main (805) 648-8949 Page 20 2 The Roof Reinforcer Ross 44. u�nil ri��` ors s,Suppor�n�-.kiUs4 and S . 1ukwito CA Aoject I0994) post ► Le b 20' Forthu art W10141 a 4' (d oss. •sec4ton 3.S" x 15.2,6" S F • bkZ (3.5) (4.2s)1. ; , .102 :41, in3 6 Iq (3.5)(13,2s) 46,,3-4.5 th1 , �o�„a�o1i - condikoni rm Loads: 1)esd load , = 20 +tsc Sr)ow load : sS p z9 C redu c ble). (zn +z5)(4) z 180 112 4t f btn l.oadl S . ; 12' U 4 _and R. U 5. are oP tole v► -tca.1 toJet tht Qa cb, in>; Loa..d .is oP bie.1ob4.1, weiitnh(a.l\. eact1 , Lhe.sj a o� consewslts rn 9.1tX a 22943 ‘10 epkor Curb s 420 l6 :at, 2148 lb _ ?AS q06 .Ib one. poin toed tic aA tslne.sctpport _3 . one . hood is 6/4" From Ve supporb, www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 Main (805) 648-8949 Page 21 2 The Roof Reinforcer G.331 V f A Rea c.%ohs Ross 44 . , 'Cuw tLt, wA Project 10ricic. i 1, Cu.. 11'.3o ?IQ . �120 21 Mk•e o aVG.(Co •33 / + (I8o)(2o)00' — 20,28 - a 51341.18 4 34o00 « RS = 2081.40. 20 .olbta _ . 160(2o) 4- 2081 0704 1 24141 M .. 1. (2084)(11.sa) :. 1209a bVb . 2 • www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 12 - 241c,2s 209 1 . Main (805) 648-8949 Page 22 The Roof Reinforcer ternands _Sties r ! uk W:+la , _ 1N A - Proze- Taoga Ito gq 12� 1...1.1- a4 t g st -pAse.3 _ (.5.L24tq.) Assam/ tch. _ Lu'1'Nlow aroole. ats -_L F._4t►.1 E ge •.�' r . Fb ... 1:209_0.25)...1$12,2„ipsi, _22S.psL. 7.r www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 Main (805) 648-8949 Page 23 I I DESIGN CRITERIA City of Tukwila Building Division/Permit Center 6300 Southcenter Blvd. #100 Tukwila, WA 98188 (206) 431-3670 2012 IRC & IBC TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GROUND SNOW LOAD WIND DESIGN SEISMIC DESIGN (0 CATEGORY SUBJECT TO DAMAGE FROM WINTER DESIGN TEMP ('' ICE BARRIER UNDERLAYMENT REQUIRED `» FLOOD HAZARDS " AIR FREEZING INDEX 1° MEAN ANNUAL TEMP' (d) Speed (mph) Topographic effects ('" Weathering ' Frost line depth" Termite (" 25 85 NO Dl Moderate 12" NA 20 Not Required (See map) N/A 51.4 deg. For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code. The weathering column shall be filled in with the weathering index (i.e., "negligible," "moderate" or "severe") for concrete as determined from theWeathering Probability Map [Figure R301.2(3)]. The grade of masonry units shall be determined from ASTM C 34, C 55, C 62, C 73, C 90, C 129, C 145, C 216 or C 652. b. The frost line depth may require deeper footings than indicated in Figure R403.1(1). The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade. c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map [FigureR301.2(4)].Wind exposure category shall be determined on a site -specific basis in accordance with Section R301.2.1.4. e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the International Plumbing Code. Deviations from the AppendixDtemperatures shall be permitted to reflect local climates or local weather experience as determined by the building official. f The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. The jurisdiction shall fill in this part of the table with (a) the date of the jurisdiction's entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas), (b) the date(s) of the currently effectiveFlRMandFBFM, or other flood hazardmap adopted by the community, as may be amended. h. In accordance with Sections R905.2.7.1, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with "YES". Otherwise, the jurisdiction shall fill in this part of the table with "NO". i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF -days) from Figure R403.3(2) or from the 100-year (99%) value on the National Climatic Data Center data table "Air Freezing Index- USA Method (Base 32°Fahrenheit)" at http://www.ncdc.noaa.gov/oa/fpsf/AFI-pubreturn.pdf. j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table "Air Freezing Index -USA Method (Base 32°Fahrenheit)" at http://www.ncdc.noaa.gov/oa/fpsf/AFI-pubreturn.pdf. k. In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall indicate "NO" in this part of the table. Page 24 DRAWING # DCD H019 REVISION # ' 2 DATE 10/01/2014 Rev. Date For ROSS 44 VAC JPCHAD SAT= L TE VIEW Is SHEET INDEX es Sprint Share Spits Authorrty Spiting ;nods Azte:a Mexican it Pesraurants Famous Ddse s tiar•6-Oue ti Ashley Furniture Hotne9ture ea Old Navy Starhuck: 'k) Apptehee's tt Dress for Lew limed apparel, et 8 housewares Cost Plus World Market ea David's & dal WORK SITE Ti ilaId fir i;i,t1121r�c iu VIC \ ITY VAP SO.0 — TITLE SHEET S1.0 — ROOF FRAMING PLAN S1.1 — MECHANICAL PLACEMENT PLAN f 0 The Roof Reinforcer www.TheRoofReinforcer.com 434 East Main Street Suite B Ventura CA 93001 (805) 648-8949 NI Project Information I2OSS DI ESS FOR LESS Ross 44 17672 Southcenter Pk Tu ,1 '=188 Sheet Title TITLE SHEET Project No. 10996 Drawn by CB Checked by TM Date 07/01/2015 Scale NONE Sheet No. S000 Page 25 RTU 7 I II RTU 5 6-H RTU 4 RTU 2 RTU 6 RTU 1 ME1 j , NO IN SC /0,, Ore , Rev. Date For www.TheRoofReinforcer.com 434 East Main Street Suite B Ventura CA 93001 (805) 648-8949 Project Information ROSS DRESS FOR LESS Ross 44 17672 Southcenter Pkwy Tu. 88 Sheet Title ROOF FRAMING PLAN Project No. 10996 Drawn by CB Checked by TM Date 07/01/2015 Scale 1:300 Sheet No. S .0 Page 26 Rev. Date For / /— ) \ y 210'-10" / 30'-5" / 60' / 60' / 60'-5" I o 1 0 b ) 0 — — RTU 7 '0-- tCNI N RTU 5 — I r. c EXISTING EQUIPMENT RTU TONNAGE MFR MODEL WEIGHT 1 5 TRANE WC C 060F400B B 529 2 5 TRANE WC H060A400BA 602 4 17 TRANE SAC C —C 174—A 2030 5 17 TRANE SAC C —C 174—A 2030 6 2.5 TRANE SAHB —B 256—A 445 7 5 LENNOX CHP16-653-9G 521 FRONT OF STORE NEW EQUIPMENT RTU TONNAGE MFR MODEL WEIGHT ADAPTOR TOTAL WEIGHT 1 5 LENNOX KHA060S4B 796 188 984 2 5 LENNOX KHA060S4B 796 235 1031 4 17 LENNOX KHA240S4M 2298 420 2718 5 17 LENNOX KHA240S4M 2298 420 2718 6 2.5 LENNOX KHA036S4D 720 485 1205 7 5 LENNOX KHA060S4B 796 198 994 MECHANICAL PLACEIV ENT PLAN T ' oo . ice• -'nicer www.TheRoofReinforcer.com 434 East Main Street Suite B Ventura CA 93001 (805) 648-8949 Project Information IZOSS DRESS FOR LESS Ross 44 17672 • enter Pkwy 88 Sheet Title IV EC HAIL I CAL PLACEV ENT PLAN Project No. 10996 Drawn by CB Checked by TM Date 07/01/2015 Scale 1:400 Sheet No. SO1 Page 27 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 41 00EL NO. WCC OOBB 1"MF6. DATE 08/98 r _ um', (1) 9.8 RLA 460 MOT ( ) 21 FLA 440 _ *NOT. ( 1) 1.7 FLA 460 Tewi Psi H G$ 300 Low IS A!#'rwRWR*Pfl 22 'A' cm" 12 FACTpY fofi 11481 ALLA TIQ(y Writ. YETAt_ YL AiR osoitier DUCT 0011. V T *brim I0.11 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 1 10996 SER4L r/a. L.331 UlTABLE FOR v3PNtOr t v ' PN 6Oiir1PH61 Main (805) 648-8949 Page 28 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 1 10996 Main (805) 648-8949 Page 29 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 1 RTU 1 (DOWNSHOOT) 10996 Page 30 Main (805) 648-8949 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 RTU 1 _ a rANDAHD INC. t rrE TRMIYE CO. mC'c)ELNO. :+t,FG`" "t40O3(4 SET"(ALIMG� StJIT.L' Ft_s}v 1-XiTLXJ Fl., 14,11 'G. DATE 0 f 9 Cpn. MOT. ? ` r 1,LA c.. 'AL''i i t 0 C; MOT. ( i) t a FFI 36C" 4©w , HECi4FC-EF—IANI 22 F y,L rt URYY' C.4ARCIE -iF.e" Lt'R www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 2 10996 Main (805) 648-8949 Page 31 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 2 RTU 2 10996 Main (805) 648-8949 Page 32 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 2 RTU 2 10996 Main (805) 648-8949 Page 33 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 2 (DOWNSHOOT) RTU 2 10996 Main (805) 648-8949 Page 34 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 4 RTU 4 10996 Main (805) 648-8949 Page 35 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 4 RTU 4 10996 Main (805) 648-8949 Page 36 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 4 RTU 4 10996 Main (805) 648-8949 Page 37 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 4 YJ Offer THE TRAN5 CO / I:OIFv 11-'":GF L1• ..,....._.1 1 RTU 5 10996 Main (805) 648-8949 Page 38 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 5 RTU 5 10996 Main (805) 648-8949 Page 39 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 5 RTU 5 10996 Main (805) 648-8949 Page 40 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 5 RTU 5 10996 Main (805) 648-8949 Page 41 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 5 vour&6E ray. COMrRie Oii 71341OR EAM non G. u. —_ A,MP MENil RCA H.rtiti l�r114�dhi 4. wJ. RTU 6 I0996 itnra�`�. .:. MAXrow iY'r4 3 ice.MiliMaireNfSSAifke cJe'wt rY'4 Main (805) 648-8949 Page 42 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 6 RTU 6 10996 Main (805) 648-8949 Page 43 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 6 RTU 6 10996 Main (805) 648-8949 Page 44 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 6 (DOWNSHOOT) RTU 6 10996 Main (805) 648-8949 Page 45 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofRein forcer.com 434 E. Main Street B, Ventura, CA 93001 rMlts: CHP16— 653 947 S'N:56996 09/42 w MOM1 M....if v 'nvwwnf MOTw 'ri'c44 e4U V �'� GMt1wW1 LMNYIA,iM ih..i "s RTU 7 RTU 7 10996 Main (805) 648-8949 Page 46 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforeer.com 434 E. Main Street B, Ventura, CA 93001 RTU 7 10996 Main (805) 648-8949 Page 47 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 www.TheRoofReinforcer.com 434 E. Main Street B, Ventura, CA 93001 RTU 7 10996 Main (805) 648-8949 Page 48 The Roof Reinforcer PHOTOGRAPHIC REPORT Ross 44 17672 Southcenter Pkwy, Tukwila, WA 98188 RTU 7 www.Th eRoofRein forcer.co m 434 E. Main Street B, Ventura, CA 93001 Main (805) 648-8949 10996 Page 49 lERNATI (ENGINEERING DMA PACKAGED HEAT PUMPS - 50hz) wmor ____ "y ORT DIV\S\ CHP16H-261/CHP16-413, -513 AND -653 PACKAGED UNITS - HEAT PUMPS 6.6 to 15.7 kW (22 500 to 53 500 Btuh) Cooling Capacity 5.7 to 15.0 kW (19 600 to 51 400 Btuh) Optional Electric Heat CHP16H Rooftop Installation With Combination Supply and Return Air System f CHP16H Residential Rooftop Installation CHP16 7.0 to 17.6 kW (2 to 5 Ton) Bulletin #490036 October 1994 Supersedes October 1990 CHP16 Basic Unit CHP16H-261 Basic Unit CHP16 Rooftop Installation With Horizontal Economizer CHP16 Rooftop Installation With Combination Supply and Return Air System Page 50 NOTE — Due to Lennox' ongoing committent to quality, Specifications, Ratings and Dimensions subject to change without notice. ©1994 Lennox Industries Inc. ( SPECIFICATIONS - CHP16H-261 AND CHP16-413 Unit Model Number CHP16H-261 CHP16-413 *Cooling Rating Total cooling capacity - kW (Btuh) 6.6 (22 500) 9.8 (33 300) Total power input - kW 2.22 3.28 Coefficient of Performance - Output/Input 2.9 3.0 Energy Efficiency Ratio - BtuhlWatt 10.1 10.2 *High Temperature Heating Ratings Heating Capacity - kW (Btuh) 5.7 (19 600) 9.5 (32 400) Total Power Input - kW 1.8 2.8 Coefficient of Performance - Output/Input 3.1 3.4 *Low Temperature Heating Ratings Heating Capacity - kW (Btuh) 3.0 (10 400) 5.1 (17 500) Total Power Input - kW 1.5 2.3 Coefficient of Performance - Output/Input 2.0 2.2 *Sound rating number (bels) 7.8 7.8 Refrigerant HCFC-22 charge furnished - kg (ozs.) 2.3 (82) 3.0 (107) Indoor Blower Blower wheel nominal diameter x width - mm (inches) 229 x 178 (9 x 7) 254 x 178 (10 x 7) Motor output - W (hp) 250 (1/3) 373 (1/2) Indoor Coil Net face area - m2 (ft.2) 0.30 (3.2) 0.38 (4.1) Tube outside diameter - mm (inches) - number of rows 9.5 (3/8) - 3 9.5 (3/8) - 3 Fins per m (fins per inch) 591 (15) 591 (15) Outdoor Coil Net face area - m1 (ft.� Outer coil 0.63 (6.8) 0.80 (8.6) Inner coil - - - - 0.77 (8.3) Tube outside diameter - mm (inches) - number of rows 9.5 (3/8) - 2 9.5 (3/8) - 2 Fins per m (fins per inch) 787 (20) 787 (20) Outdoor Coil Fan Diameter - mm (inches) - number of blades 457 (18) - 4 508 (20) - 4 Air volume - Us (cfm) 745 (1580) 875 (1850) Motor output - W (hp) 124 (1/6) 149 (1/5) Motor input - W 150 185 Condensate drain size - male pipe thread - mm (inches) 19.1 (3/4) tNumber and size of filters - mm (inches) - - - - (1) 406 x 635 x 25 (16 x 25 x 1) Net weight of basic unit - kg (lbs.) 137 (303) 167 (368) Shipping weight of basic unit - kg (Ibs.) (1 Package) _ 167 (368) 196 (432) *Sound rating number rated at test conditions for Air Conditioning and Refrigeration Insti ute (ARI) Standard 270. *The rating test conditions are those included in Air Conditioning and Refrigeration Institu e (ARI) Standard 210/240 while operating at rated voltage and air volumes. Cooling Ratings: 35°C (95°F) outdoor air temperature, 26.7°C (80°F) dry bulb and 19.4°C 67°F) wet bulb entering indoor air. High Temperature Heating Ratings: 8°C (47°F) db/6°C (43°F) wb outdoor air temperature and 21 °C (70°F) entering indoor air. Low Temperature Heating Ratings: -8°C (17°F) db/-9°C (15°F) wb outdoor air temperature and 21 °C (70°F) entering indoor air. 1-Filters for CHP16H-261 basic unit are not fumished and must be provided by installer. ( OPTIONAL ACCESSORIES - CHP16H-261 AND CHP16-413 (Must Be Ordered Extra) Unit Model Number CHP16H-261 CHP16-413 Duct Enclosure - Net Weight - kg (Ibs.) Number and size of fiberglass filter - mm (inches) 1 RDE16-31 - 43 (94) (93G44) (1) 508 x 508 x 25 (20 x 20 x 1) _ _ _ _ Roof Mounting Frame - Net Weight - kg (Ibs.) RMF16-31 - 36 (80) (30H79) RMF16-41 - 34 (75) (73H79) tEconomizer Dampers with Gravity Exhaust Model Number 3 Position Net Weight - kg (Ibs.) REMD16-41 - 22 (48) (58H73) Modulating Net Weight - kg (Ibs.) REMD16M-41 - 22 (48) (58H72) Number and size of filters - mm (inches) Indoor •(1) 406 x 635 x 25 (16 x 25 x 1) (polyurethane) Outdoor (1) 349 x 635 x 25 (13-3/4 x 25 x 1) (aluminum mesh) Horizontal Economizer Dampers Model Number 3 Position Net Weight - kg (Ibs.) - - - - EMDH16-41 - 50 (110) (14H97) Modulating Net Weight - kg (Ibs.) - - - - EMDH16M-41 - 50 (110) (23H03) Number and size of filters - mm (inches) Indoor - - - - (1) 508 x 635 x 25 (20 x 25 x 1) (fiberglass) Outdoor - - _ - (1) 203 x 610 x 25 (8 x 24 x 1) (aluminum mesh) Gravity Exhaust Dampers - Net Weight - kg (Ibs.) - (Net Face Area) - - - - GEDH16-65 - 2 (4) (23H06) Use with EMDH16 Outdoor Coil Guards 47J25 47J23 Roof Curb Power Entry Kit (conduit size) - mm (inches) (18H70) 13 (1/2) (18H71) 25 (1) (18H72) 38 (1-1/2) Lifting Lug Kit 44H92 - - - - Differential Enthalpy Control 54G44 Ceiling Supply and Return Air Diffusers Net Weight kg (Ibs.) Step -Down RTD9-65 - 30 (67) (27G87) Flush FD9-65 -17 (37) (27G86) Transition SRTH16-65 - 8 (17) (15H03) SRT16-65 - 9 (20) (15H02) Outdoor Air Dampers (Manual) - Net Weight - kg (Ibs.) Number and size of filters - mm (inches) OAD3-46/65 - 3 (7) (23591) OAD16-41 - 5 (12) (15H00) - - - - (1) 127 x 432 x 25 (5 x 17 x 1) Unit Stand -Off Mounting Kit - Net Weight - kg (Ibs.) LB-62742CA (38H18) contains six stand-offs Timed -Off Control LB-50709BA (32F21) •Indoor filter is not furnished with economizer. RLMU16 Utilizes filter fumis with yP16 unit 1-When economizer is used with CHP16H-261, a two stage cooling thermos Johd. - 7- ( SPECIFICATIONS - CHP16-513-653 Unit Model Number CHP16-513 CHP16-653 *Cooling Rating Total cooling capacity - kW (Btuh) 12.6 (43 200) 15.7 (53 500) Total power input - kW 4.23 5.06 Coefficient of Performance - Output/Input 3.0 3.1 Energy Efficiency Ratio - Btuh/Watt 10.2 10.6 *High Temperature Heating Ratings Heating Capacity - kW (Btuh) - 12.5 (42 600) 15.0 (51 400) Total Power Input - kW 3.4 4.4 Coefficient of Performance - Output/Input 3.7 3.4 *Low Temperature Heating Ratings Heating Capacity - kW (Btuh) 6.8 (23 300) 8.8 (30 000) Total Power Input - kW 2.7 3.4 Coefficient of Performance - Output/Input 2.5 2.6 *Sound rating number (bets) 8.0 8.0 Refrigerant HCFC-22 charge furnished - kg (ozs.) 4.3 (152) 4.2 (148) Indoor Blower Blower wheel nominal diameter x width - mm (inches) 254 x 203 (10 x 8) 305 x 203 (12 x 8) Motor output - W (hp) 373 (1/2) 373 (1/2) Indoor Coil Net face area - m1(ft.1) 0.54 (5.8) 0.54 (5.8) Tube outside diameter - mm (inches) - number of rows 9.5 (3/8) - 3 9.5 (3/8) - 3 Fins per m (fins per inch) 591 (15) 591 (15) Outdoor Coil Net face area - m1 (ft.2) Outer coil 1.33 (14.3) 1.33 (14.3) Inner coil 0.92 (9.9)1.28 13.8 ( ) Tube outside diameter - mm (inches) - number of rows 9.5 (3/8) - 1.7 9.5 (3/8) - 2 Fins per m (fins per inch) V 787 (20) 787 (20) Outdoor Coil Fan Diameter - mm (inches) - number of blades 610 (24) - 4 610 (24) - 4 Air volume - Us (cfm) 1415 (3000) 1415 (3000) Motor output - W (hp) 187 (1/4) 187 (1/4) Motor input - W 285 285 Condensate drain size - male pipe thread - mm (inches) 19.1 (3/4) Number and size of filters - mm (inches) (1) 508 x 635 x 25 (20 x 25 x 1) Net weight of basic unit - kg (Ibs.) (1 Package) 213 (470) 236 (521) Shipping weight of basic unit - kg (Ibs.) (1 Package) 251 (553) 274 (604) *Sound rating number rated at test conditions for Air Conditioning and Refrigeration Insti ute (ARI) Standard 270. *The rating test conditions are those included in Air Conditioning and Refrigeration Institute (ARI) Standard 210/240 while operating at rated voltage and air volumes. Cooling Ratings: 35°C (95°F) outdoor air temperature, 26.7°C (80°F) dry bulb and 19.4°C (67°F) wet bulb entering indoor air. High Temperature Heating Ratings: 8°C (47°F) db/6°C (43°F) wb outdoor air temperature and 21°C (70°F) entering indoor air. Low Temperature Heating Ratings: -8°C (17°F) db/-9°C (15°F) wb outdoor air temperature and 21 °C (70°F) entering indoor air. 1-Filters for CHP16H-261 basic unit are not furnished and must be provided by installer. ( OPTIONAL ACCESSORIES - CHP16-513-653 (Must Be Ordered Extra) Unit Model Number CHP16-513 I CHP16-653 s Roof Mounting Frame - Net Weight - kg (lbs.) RMF16-41 - 34 (75) (73H79) or RMF16-65 - 39 (86) (73H81) Economizer Dampers with Gravity Exhaust Model Number 3 Position Net Weight - kg (Ibs.) REMD16-65 - 30 (66) (58H75) Modulating Net Weight - kg (Ibs.) REMD16M-65 - 30 (66) (58H74) Number and size of filters - mm (inches) Indoor (1) 508 x 635 x 25 (20 x 25 x 1) (polyurethane) Outdoor (1) 451 x 635 x 25 (17-3/4 x 25 x 1) (aluminum mesh) Horizontal Economizer Dampers Model Number 3 Position Net Weight - kg (Ibs.) EMDH16-65 - 59 (130) (14H98) Modulating Net Weight - kg (Ibs.) EMDH16M-65 - 59 (130) (23H02) Number and size of filters - mm (inches) Indoor (2) 356 x 635 x 25 (14 x 25 x 1) (fiberglass) Outdoor (1) 203 x 711 x 25 (8 x 28 x 1) (aluminum mesh) Gravity Exhaust Damper GEDH16-65 - 2 (4) (23H06) use with EMDH16 Differential Enthalpy Control 54G44 Outdoor Coil Guards 47J24 Roof Curb Power Entry Kit (conduit size) - mm (inches) 18H70 13 (1/2) 18H71 25 (1) 18H72 38 (1-1/2) Ceiling Supply and Retum Air Diffusers Net Weight kg (Ibs.) Step -Down RTD9-65 - 30 (67) (27G87) Flush FD9-65 - 17 (37) (27G86) Transition SRT16-65 - 9 (20) (15H02) Outdoor Air Dampers - Net Weight - kg (Ibs.) Number & size of filters - mm (inches) OAD16-65 - 5 (12) (15H01) (1) 208 x 432 x 25 (8 x 17 x 1) Unit Stand -Off Mounting Kit - Net Weight - kg (lbs.) LB-62742CA (38H18) contains six stand-offs Low Ambient Control Kit LB-57113BM (27J00) Timed -Off Control Page 5' LB-50709BA (32F21) ( DIMENSIONS — inches (mm) CHP16H-261 BASIC UNIT CORNER WEIGHTS Model Number AA BB CC DD lbs. kg lbs. kg lbs. kg lbs. kg CHP16H-261 67 30 56 25 82 37 98 44 OUTDOOR COIL INTAKE AIR 43. OUTDOOR COIL AA INTAKE AIR O u ELECTRICAL DD INLETS BLOWER I( ( ' I ENTER —� I OF GRAVITY 4_ __I I\ FF ) "- /P 4_41 - oi1/4/ �--� _ COMPRESSOREE / i I -\ OPTIONAL I ELECTRIC HEAT CENTER OF GRAVITY Model Number EE FF inch mm inch mm CHP16H-261 I 17-7/8 454 27-5/16 694 BB RETURN a TOP VIEW OUTDOOR COIL EXHAUST AIR 50-1/8 (1273) ELECTRICAL INLETS �1 OUTDOOR COIL INTAKE AIR CC SUPPLY AIR -7 OAD3-46/65 OPTIONAL MANUAL OUTDOOR AIR DAMPER RETURN AIR DUCT (Not Furnished) pl5/8 43-3/4 (16) (1111) CONDENSATE DRAIN 1-5/8 zs (41)i y LIFTING LUG HOLES (Both Sides) 5/8 (16)i # # 40—(178)� 11-1/8 21-7/8 (283) (556) FRONT VIEW I 23 (584) 5-1/2 (140) 3-1/4 3-1/4 (83) (83) OPTIONAL STAND-OFF MOUNTING KIT (6) (Field Installed) SIDE VIEW ( INSTALLATION CLEARANCES — inches (mm) CHP16H-261 BASIC UNIT WITH OAD3-46/65 OUTDOOR AIR DAMPER 6 (914)./ (936/14) �� /BLOWI=R /41 • ( ) a OAD3-46/65 OUTDOOR AIR DAMPER Alow adequate dearance for dud and OAD3-46665 installation. res • CHP16H-261 UNIT WITH RDE16-31 DUCT ENCLOSURE AND REMD16-41 ECONOMIZER DAMPER SECTION V/17/y RDE16 DUCT ENCLOSURE REMD16 I ECONOMIZER DAMPERS P SINGLE PACKAGE UNIT Avf /4i1P NOTE — Top Clearance Unobstructed. NOTE — Top Clearance Unobstructed. 1 Page 53 — 1g_ ( DIMENSIONS — inches lmm) CHP16-413-513-653 BASIC UNITS CORNER WEIGHTS Model Number AA BB CC DD Ibs. kg Ibs. kg Ibs. kg Ibs. kg CHP16-413 72 33 77 35 113 51 106 48 CHP16-513 93 42 93 42 142 64 142 64 CHP16-653 102 46 108 49 160 73 151 68 i 3 (76) i 3 (76) TOP VIEW BASE SECTION 3 (76) HORIZONTAL HORIZONTAL SUPPLY AIR RETURN AIR OPENING OPENING BACK VIEW (With Horizontal Supply & Return Air) 5/8 (16) L — OPTIONAL OAD16 OUTDOOR AIR DAMPER (Fe FILTER AND Id Installed) K FILTER RACK (Furnished With CHP16-513 and 653) 1, 1 Oo =_{==� 1.5/8(41) Ot 4 CONDENSA DRAIN END VIEW O + C CENTER OF GRAVITY Model Number EE FF inch mm inch mm CHP16-413 29 737 27-3/8 695 CHP16-513 36-1/4 921 31-7/16 799 CHP16-653 35-1/4 895 31 787 OPTIONAL M OAD16 OUTDOOR AIR DAMPER (Field Installed) 314 (19) FILTER AND FILTER RACK (Furnished with CHP16-413) OPTIONAL STAND-OFF MOUNTING KIT (6) (Field Installed) ELECTRICAL INLETS 5-1/2 (140) 4 OPTIONAL ELECTRIC HEAT TOP VIEW LIFTING BRACKETS CHP6-513/653 ONLY HOLES CHP16-413 ONLY (Both Sides) FRONT VIEW Cc OUTDOOR COIL EXHAUST AIR r A t OPTIONAL STAND-OFF MOUNTING KIT (6) (Field Installed) END VIEW OUTDOOR COIL INTAKE AIR 5-1/2(140) 4 Model Number A B C D E F G inch mm inch mm inch mm inch mm inch mm inch mm inch mm CHP16-413 46 1168 60 1524 23 584 18 457 13 330 13 330 10 254 CHP16-653 CHP16-513 II 52 1321 72-1/2 1842 29 737 22 559 18 457 22 559 7-1/2 191 Model Number H J K L M inch mm incti mm inch mm inch mm inch mm CHP16-413 3 76 4 102 6-1/2 165 2 51 5 127 CHP16-513 CHP16-653 5 127 3 7 Faet 1/8 54 156 5 127 8 203 —21— to 15 tons reliable, efflcienf operation and easy installation 1 Gas heat 5-15 ton cooling only and electric heal 7'/2 to 15-ton Condenser section overhangs root curb Heating compartment Lifting lugs accom- modate a wide variety of lifting methods. Burning flame view- ing port enhances ease of maintenance. Forced combustion 10, 121, 15 ton dual blower, heat exchanger circuited for stand-by is made of aluminized operation. steel. Horizontal supply and return option is available. Quick release gas- keted access panels provide easy access to components. Pag@ 55 12 to 5 tons !ftane quality exfends to small sizes, too COOLING ONLY/ELECTRICAL HEATING 21/2 TO 5 TON Electric heat module slides into discharge air passage Factory -installed internal high velocity air filter Quiet direct -drive evaporator blower assembly Electronic spark ignitor Aluminum coated die formed heat exchanger_ Internalcircuit breaker eliminates need to field install disconnect (single phase only) Crankcase heater Combustion air blower Crankcase heater Pagn 56 MODEL NOMENCLATURE SELF CONTAINED A = COOLING ONLY F = GAS FIRED CONVERTIBLE UNIT AIRFLOW (DOWNFLOW OR HORIZONTAL) DESIGN SEQUENCE C B B75 6 H f... HEAT CAPACITY (GAS) L = LOW HEAT H = HIGH HEAT UNIT VOLTAGE 6 = 208-230/60/3 (SACB/SACC) 3 = 208-230/60/3 (SFCB) 4 = 460/60/3 5 = 575/60/3 COOLING CAPACITY B50 = 5 TON B75 = 7.5 TON C 10 = 10 TON C12 = 12.5 TON C15 = 15 TON SELECTION PROCEDURE COOLING CAPACITY Step 1 — Calculate the building's total and sensible cooling loads at design conditions. Use the Trane calculation form or any other standard accepted method. Step 2 — Size the equipment using Table 44-3, to match the cooling loads at design conditions. Example: The following are the building cooling requirements: a. Electrical Characteristics: 460/60/3 b. Summer Design Conditions: Entering Evaporator Coil: 80 F DB/67 F WB Outdoor Ambient: 95 F c. Total Cooling Load: 110 MBh d. Sensible Cooling Load: 70 MBh e. Airflow Quantity: 4,000 Cfm External Static Pressure: 0.5 in. wg Table 44-3 shows a SACC C10 has a gross cooling capacity of 131 MBh and 101 MBh sensible capacity (0.77 x 131) at 95 F DB ambient with 4,000 cfm of 80 F DB and 67 F WB air entering the evaporator. To find net cooling capacities, fan motor heat must be sub- tracted. Determine total unit static pressure: External Static 0 5 in. Standard Filter (Table 48-1) 0 02 in. Electric Heat (Table 48-1) 0 05 in. Economizer (Table 48-1) 0 06 in. Unit Total Static Pressure 0 63 in. With 4,000 cfm and 0.63 inches sp, enter Table 47-1 which shows 2.99 bhp at 926 rpm required. Chart 47-1 shows 2.99 bhp results in 8.9 MBh fan heat. Net capacities are 122.1 MBh total (131 MBh gross — 8.9 MBh fan heat) and 92.1 MBh sensible (101 MBh — 8.9 MBh fan heat). HEATING CAPACITY Step 1 — Calculate the building heating load using the Trane calculation form or other standard accepted method. Step2 — Size the system heating capacity to match the calcul- ated building heating load. Following are building heating requirements: a. Total heating load of 150 MBh b. 4,000 cfm (select to match the cooling cfm required) c. 80 F DB entering air condition 1. Electric Heat: For the SACC C10-ton unit selected, operating on 460-volts, there is a 19.5 kw (66.6 MBh) minimum and 60 kw (204.8 MBh) maximum heating capacity available at nominal cfm (Table 46-1). At 4,000 cfm, 45 kw (153.6 MBh) best matches the building heating requirements. Pag*257 TABLE 49-1— Electric Hest Wirhta Data Unit Sae with Electric Heat Sae voltage 206' 240 • 480 575 Min. Circ. Amp Dual Element Fuse Size Max. Fuse Sae Mal. Circ. Amp Dual Element Fuse Size Max. Fuse Size Min: Circ. Amp: Dual Element Fuse Size Max. Fuse Sae Min. Cue. Amp Dual Element Fuse Sae Max. Fuse Size SACS B50w.r10.0kw 43 50 60 43 50 60 20 25 30 17 20 25 173kw 54 60 60 84 70 70 29 30 30 23 25 25 30.8kw 84 90 90 103 110 110 — — — — — — 35.2kw 99 100 100 116 125 125 55 60 60 46 50 50 SACC 675 w//14.4 kw h1r 53 50 60 53 50 60 27 25 30 — — — 20.4kwhtr 71 60 80 71 60 80 36 30 40 — — __ 26.1 kwhtr 88 82 90 88 80 90 45 40 45 — _ — 44. , kw htr 142 125 150 142 125 150 72 60 80 59 50 60 SACC CIO wi19.5 kw "tr 79 60 100 79 80 100 36 35 45 — — — 45.0 kw htr 149 125 150 149 125 150 74 60 80 — _ _ 60.0 kw n1r 194 150 200 194 150 200 96 80 100 77 70 80 SACC C 12 w424 kw htr 95 100 125 95 100 125 45 45 50 — — — 45 kw Mr 149 125 150 149 125 150 74 60 80 — — — 60 kw htr 194 150 200 194 150 200 96 80 100 77 70 BO SACCC15w130kwhtr 117 185 158 117 125 150 56 60 70 — — — 60 kw h11 201 150 225 201 150 225 100 80 103 80 70 BO 90kw011 292 225 300 292 225 300 145 110 150 116 110 125 'Heater output is 75 percent o1 npmroaf kw TABLE 49.2 — Unit and ACosssory Wsiahts (Pounds' Model Unit. Accessories (Net 1M8.) Econornizer DA Damp. Motor OA Damp ROM Curb • Conc. Dirt. Corn. Dud Oversize Motor Kw Hof Water and Si. Col Low Ambient 2.peed Motor Net Ship. Min Max SACBB50 695 735 75 25 30 142 11 185 35 19 23 — 50 — SACC 875 1040 1260 210 60 90 135 15 250 35 30 60 — 50 — SACCC10 1700 1975 290 90 95 1E5 25 260 90 50 60 77 — 20 SACCC12 1875 2190 295 90 110 165 31 320 90 50 60 85 — 20 SACC C15 2 2375 330 100 120 175 31 320 90 50 70 95 — 20 SFCB 850 950 1140 125 60 75 125 11 185 35 — — — 50 — SFCB 075 1180 1400 210 60 90 135 15 260 35 — — — 50 — SFCB CIO 1755 2030 290 90 95 165 25 260 90 — — — — 20 SFCBC12 1925 2240 295 90 110 165 31 320 90 — — — — 20 SFCBCIS 2275 2620 330 100 120 165 31 320 90 — — — — 20 CHART 4941— Indoor Fan Motor Heat 20 191 18 17 16 15 14' 131 12 11: .c m 10I 91 8'' 7 6 5' 1 2 3 4 5 6 7 8 9 10 11 12 Indoor Fan Brake Horsepower (bhp) TABLE 49.3 — Unit Winks Data Model act** Mn. Circuit Ampac6y Mal Fuse Size OW EkYn ilt Fuse Sias SACS 8506 206-230430/3 43 60 50 SAC88504 460/60/3 20 30 25 SACS 0505 575503 17 25 20 SACC 8756 201323060/3 51 70 50 SACC B754 4800:4 25 35 25 SACC8755 575/606 20 25 20 SACCC106 208-230/603 79 100 80 SACCC104 48160/3 36 45 35 SACCC125 575/66f3 30 35 30 UGC C 126 206-230/60/3 95 125 100 SACCC124 460160/3 45 50 45 SACCC125 5751603 35 45 35 SACC C 156 20-231U6043 117 150 125 SACCC154 480/60r3 56 70 60 SACCC155 575/E0/3 44 50 45 SFCB 13503 2013-2306049 34 50 40 SFCB8504 460/603 17 25 20 SFCB 6505 575/60/3 14 20 20 SFC88753 208-23050/3 41 60 50 SFC88754 460480/3 20 30 25 SFCB 8755 57580/3 16 25 20 SFCBC103 208-230/60/3 65 60 70 SFCB C104 460/60/3 35 45 40 SFCBC105 575/60/3 28 35 35 SFCBC123 208-230/60/3 78 100 90 SFCBC124 480/60/3 38 50 45 SFCBC125 575/80/3 31 40 35 SFC8 C 153 206-230160/3 95 125 110 SFCBC154 460/60/3 46 60 50 SFCBC155 575/60/3 37 45 40 Pae 58 AM CONDITIONING 5 TO 15 TONS �133/e 3'-11 Vz" Me" FIGURE 7 OPTIONAL RETURN AIR FIGURE 8 6'-1" FIGURE 9 C,3Yz' OPTIONAL SUPPLY AIR 6-OW' 2%1'/" DIMENSIONAL DATA - SACC/SFCB C10-C15 7' 2V' L A 6'-6 h" 2 x 2 NAILING STRIP CONCENTRIC DUCT Pagq 59 3'-03/e" y 1'-1 ' CONCENTRIC DIFFUSER FIGURE 7 — Unit Dimensions C10 C12 C15 L 8'-3' 8"6' 9'-434' A 5'-2%' 5'-8W 6'-914` 5 4'-7%' 5'-1W 5'-911'' C 4'-3Ye' 4'-9W 5'-5' FIGURE 8 — Roof Cub CIO Ct2 C15 A 4'-3" 4'-9' 5'-5' 9 5'-11z' 5'-9c' C 4'-9' 5'-3' 5'-11' ALL DIMENSIONS APPROXIMATE CERTIFIED PRINTS ON REQUEST FIGURE 9 — Concentric Duct C10 C12 C15 A 3'-6' 4' 4' 6 2'-3' 2'-9' 2.-9` C3'-6' 4' 4' 0 2'-3" 2'-9' 2'-9' NOTE: Concentric duct connects to roof curb. e MODEL NOMENCLATURE SELF CONTAINED A = Cooling Only F = Gas Fired HORIZONTAL DISCHARGE DESIGN SEQUENCE S F H T T C 30 2 L T SELECTION PROCEDURE COOLING CAPACITY Step 1 — Calculate the building's total and sensible cooling loads at design conditions. Use the Trane calculation form or any other standard accepted method. Step 2 — Size the equipment using Table 66-1 and 66-2, to match the cooling loads at design conditions. Example: The following are the building cooling requirements: a. Electrical characteristics: 208-230/60/1 b. Summer Design Conditions: Entering Evaporator Coil: 80 F DB/67 F WB Outdoor Ambient: 95 F c. Total Cooling Load: 36 MBh d. Sensible Cooling Load: 27 MBh e. Airflow Quality: 1320 Cfm Table 68-2 shows a SFHC 302 has a net cooling capacity of 37 MBh with 79 percent sensible capacity at 95 F DB ambient with 1200 cfm of 80 F DB and 67 F WB air entering the evaporator. Since 1320 cfm is 10 percent from the nominal 1200 cfm, a total cooling correction factor from Table 63-5 of 1.015 must be multiplied times total capacity. Also a sensible cooling correc- tion factor of 1.030 must be multiplied times sensible heat capacity. The cfm range in Table 63-5 must not be exceeded for proper unit operation. After cooling correction factors have been applied, the 3-ton unit has a cooling capacity of 38 MBh and 30 MBh sensible. Both valves will satisfy building cooling load requirements. HEAT CAPACITY (GAS) L = Low Heat H = High Heat UNIT VOLTAGE 2 = 208-230/60/1 6 = 208-230/60/3 4 = 460/60/3 COOLING CAPACITY 20 = 2 Ton 25 = 21/2 Ton 30 = 3 Ton 35 = 31/2 Ton 40 = 4 Ton 50 = 5 Ton HEATING CAPACITY Step 1 — Calculate the building heating load using the Trane calculation form or other standard accepted method. Step 2 — Size the system heating capacity to match the calcul- ated building heating load. Following are building heating requirements: a. Total' heating load of 54 MBh b. 1320 cfm (selected to match the cooling Cfm required) c. 80 F DB entering air condition 1. Gas Heating For the SFHC 3 ton unit selected, there are two output capacities available, 57 MBh and 94 MBh shown in Table 68-5 the 57 MBh best matches the building heating re- quirements indicating a SFHC 30 with L heat capacity should be selected. To find leaving air temperature, multiply the temperature correction factor .91 for 4400 cfm from Table 69-1 for 1320 cfm times the temperature rise 53 F given in Table 68-5. Add the product of this multiplication (48 F) to the heat exchanger entering air temperature 80 F the sum, 128 F, is the leaving air temperature. Electric Heating For the SAHB 3 ton unit selected, operating on 240 volts, there is 5.8 Kw (19.8 MBh) minimum and 22.4 Kw (76.5 MBh) maximum heating capacity available at nominal cfm. At 1320 cfm, 17.3 Kw (59.0 MBh) best matches the build- ing heating requirements. Page 60 FIGURED 31/32 DM ENSION FRONT VIEW i% I.D. SNAP BUSHING FOR THERMOSTAT WIRES �! '4-11V16 D 3i N.P.S. DRAIN CONN FIGURE D — Unf Dimensions SINGLE-PHASE UNITS ONLY F DIA_ HOLE FOR UNIT POWER WIRES sEtp UNIT A LENGTH B WIDTH C HEIGHT D E F . G SAHB 20 - 401 301 239i16 _ 251/4 19h6 11/2 22"/32 SAHB 25 44' 732 304 239116 251 19h6 1' 22"12 SAHB 30 4613116 301/4 269116 251/4 19116 11/2 251'132 SAHB 40 572A 35'/e 299/,6 29i3h6 13 2'/e 28"h2 SAHB 50 649h6 351/2 3191,6 29'3/16 13 21/4 309/3e REAR VIEW FIGURE E FIGURE E — Duct Openings 3M I.D. SNAP BUSHING FOR THERMOSTAT WIRES UNIT H J K SAHB 20 111/4 191/2 75 SAHB 25 111 251/e 7% SAHB 30 141/4 221 7% SAHB 40 161 341 71 SAHB 50 1 WA 41% 7s F DIA. HOLE FOR UNIT POWER WIRES 'e N.P S. DRAIN CONN. CON�AnE A/R C/LC/✓ThC Page 61 V g1 FIGURE A WOPEASIONAL DATA SFHC /SFHA w PIPE 54)PPORTS FURNISHED BY OTHERS FIGURE A SFHAASFHC 25 30 35.40 Unit Dimensions SFHASFHC 2530 3540 L 58% 70% W 3214 3814 WA 23V4 27 8 16 2314 C 14% 14% NetWt .4'4-5 550 FIGURE B Supply -Return Casing Dimensions SRiASRIC 25-30 35-40 L 4314 57 W 363 42% A 34 47% Net Wt. 180 225 FIGURE C Outside Air 8 Economtaer intake Hood SFHASFNC 2530 35-40 L 34 47% 0.A. Net Wt. 56 76 Econ. Net Wt. 92 100 214- 14 N.P.T. DRAIN CONN. FIGURE E 60 FIGURE B FIGURE D CONCENTRIC DIFFUSER MOUNTING HOLES 1h OIA. (4) 2 r 2 NAILING STRIP FIGURE D — Roof Curb SRIA-SFHC 25-3) 35-40 L 41% 5514 W 363 4244 A 493 631b B 28% 34% Net W1. 56 74 FIGURE E — Concentric Dud SRIA-BRIG 2533 3540 L 21 Vs 271! W 21 27 A 15 18 B 15 18 NetWt. 60 75 Pag72 62 0 TPi4NE® PKGP-PRC010-EN Convertible Models WCC018-060F 1'/2-5Ton Pub. No. 22-1296-05-0303 (EN) Page 63 • Enthalpy Control Kit For those applications specifying an econo- mizer with enthalpy control, this control can be used in place of the dry bulb sensor or, altemately, two enthalpy controls can be paired to provide differential enthalpy control. • 25% Fresh Air Kit The kit installs over the horizontal retum air opening with six screws for downflow require- ments. It can be used on horizontal air flow applications by cutting a hole in the retum air duct or in the unit filter access panel. • Rectangular to Round Duct Kits The adapter kit can be used in either hori- zontal or downflow applications. • Low Ambient Kit An EDC provides low ambient cooling to 0° F. with some reduced capacity and pro- tects the system against evaporator icing during other unusual cooling conditions. • Lifting Lug Kit Four reusable lugs in each kit allow units to be easily lifted to rooftop installations. These PRODUCT TYPE YC TC WC DC 1 2 3 W C C = Packaged Gas/Electric = Packaged Cooling = Packaged Heat Pumps = Dual Fuel Heat Pumps AIRFLOW CONFIGURATION C = Convertible D = Downflow H = Horizontal M = Manufactured Housing X = 12 SEER Y = 13-14 SEER Z = 15-16 SEER NOMINAL NET COOLING CAPACITY (MBH) 018 = 1 1/2 Tons 024 = 2 Tons 030 = 2 1/2 tons 036 = 3 Tons 042 = 3 1/2 Tons 048 = 4 Tons 060 = 5 Tons Features and Benefits IMPACK Accessories lugs snap (no screws required) into slots in the unit drip lip channel. • Electric Heaters One family of electric heaters serves the en- tire line of 2 to 5 ton WCZ, WCY, WCC's. This will provide the highest degree of flex- ibility while allowing minimal inventory. • High Static Motor Kit Consists of a higher torque indoor fan motor. • Start Kit The kit mounts in the control box for those installations specific conditions such as ex- cessive voltage drop due to long wires. (This is a capacitor and start relay kit not a PTC device.) This kit can be a good specification buster! • Coil Guard Kit The guards are coated 1" X 3" wire grills. These grills will protect the coil from hail, kids with sticks, and normal shipping and in- stallation damage. • Single Power Entry Kit The kit minimizes installation costs by reducing the load center circuit requirement and reducing the number of circuit pulls needed. Selection Procedure Model Number Nomenclature 4 5 6 7 8 9 0 3 6 F 1 0 10 11 0 A T T 12 A SERVICE DESIGN MINOR DESIGN SEQUENCE FACTORY INSTALLED OPTIONS EXAMPLES: 0 = No factory installed options B = Oversize Motor* N = Filter Frame* T = Fan Delay Relay* * Product Deviation Required AUXILIARY HEATING CAPACITY L = Low Heat M = Medium Heat H = High Heat 0 = No Heat ELECTRICAL CHARACTERISTICS 1 = 208-230/60/1 3 = 208-230/60/3 4 = 460/60/3 W= 575/3/60 D = 380-415/3/50 MAJOR DEVELOPMENT SEQUENCE F = IMPACK G = IMPACK Plus 22-1296-05-0303 (EN) Page 44 SPACER PANEL WCC042FONLY CORNER POST WCC042-048 & -060FONLY CONDENSOR COIL WCC042F,-048 & -060F ONLY [4] 6 MM 1] z 13 MM SECT. X-X Dimensions WCC018-060F Outline — Rear NOTE: ALL DRAWING DIMENSIONS ARE IN MM (INCHES) HORIZONTAL SUPPLY OPENING DOWNFLO SUPPLY OPENING APPEARANCE SURFACE OF SUPPLY & RETURN PANEL TYPICAL CROSS SECTION OF HORIZONTAL SUPPLY & RETURN PERIMETER FLANGES HORIZONTAL RETURN OPENING EVAPORATOR COIL & BLOWER PANEL / 18116 MM / CONDENSATE DRAIN FOR 3/4 FEMALE NPT 19 MM [3] um DOWNFLOW RETURN �OPENING 76 MM L & M DIMENSIONAL SURFACE ISEE TABLE 16 MM [8] L 19 MM [4] SECT. Y-Y TYPICAL CROSS SECTION OF DOWNFLOW SUPPLY & RETURN PERIMETER FLANGES ECONOMIZER/FILTER ACCESS PANEL 119 MM [4] MODEL CORNER WEIGHT (LBS) UNIT WEIGHT A B C D E F G H J K L M N P W1 W2 W3 W4 WCC018F 66 55 72 87 280 55-1/4 36 25-3/16 18-9/16 11-1/16 6-9/16 6-13/16 17 21-5/16 25-1/2 17-1/2 10 3 4-7/16 WCCO24F WCCO3OF 77 65 89 105 336 55-1/4 36 29-3/16 18-9/16 11-1/16 6-9/16 6-13/16 17 20-13/16 25-5/16 17-1/2 10 3 4-7/16 WCC036F 97 76 85 108 366 19 24-3/16 WCC042F 94 73 80 104 351 18-13/16 24 WCC048F 126 104 127 153 511 64 5/16 45 33-3/8 21-1/16 15-1/16 4-15/16 9-1/8 21-15/16 24-5/8 28-1/2 20 14 3-1/2 8-5/16 WCCO6OF 131 108 132 159 529, 24-5/8 28-1/2 NOTE: TABLE IN INCHES ONLY 22-1296-05-0303 (EN) Page3¢5 From Dwg. 21D729988 J 0 TRANE® WC-D-4 October 1996 Second Reprint October 1999 Packaged Heat Pumps it di voyager v 3 through 20 Tons — 60HZ 5 r 22-1353-9 Tab 11 Page 66 TRANF Product Type Model Number Description PACKAGED HEAT PUMP UNIT MODEL NOMENCLATURE WC = Heat Pump, Pack- aged W C D 0 7 5 C 3 0 0 B A Service Digit Airflow Configuratio H = Horizontal D = Downflow Nominal Gross Cooling Capacity (MBh) 036 = 3 tons 048 = 4 tons 060 = 5 tons 075 = 61/4 tons 090 = 71/2 tons 120 = 10 tons 150 = 121/2 tons 180 = 15 tons 240 = 20 tons Major Development Sequence *TCI - Trane Communication Interface Minor Design Sequence Factory Installed Options Examples: 00 = Packed Stock, No Options OA = Factory Installed Downflow Economizer OB = Oversize Motor OC = Downflow Economizer and Oversize Motor OF = TCI* OG = Downflow Economizer and TCI* Electrical Characteristics 1 = 230/60/1 3 = 208-230/60/3 4 = 460/60/3 W = 575/60/3 Pagg 67 W MANE All dimensions are in inches. Dimensional 3.0 iron Data EVAPORATOR SECT ACCESS PANEL 5 I/4' 2' ELECTRICAL CONNECTION (SINGLE POINT POWER WHEN HEAT INSTALLED) CONTROL & COMPRESSOR ACCESS PANEL 83 1/16' 43 1/16' 39 3/8' 1 13/16' Downflow Unit Clearance CLEARANCE 68" 83 1/16" CLEARANCE 48" 6 3/32' TOP PANEL 1 7/8' - 2 3/8' 46 9/16' CONDENSER FAN ,''''ir 33 1/2' CONDENSER COIL 2' HOLE (UNIT POWER WIRES) 7/8' HOLE (UNIT CONTROL WIRES) See page 68 for condensate drain size and location 14' CLEARANCE 36° DOWNFLOW TYPICAL ROOF OPENING 46 9/16" Ihr CLEARANCE 36° Page 68 Dimensional `L Mrt Data All dimensions are in inches. Downflow Duct Connections — Field Fabricated 38 1/4" Horizontal Unit Supply/Retum and Unit Clearance (4 and 5 Ton Models Only) 1 1/2" CLEARANCE 68" See page 68 for condensate drain size and location CLEARANCE 48" 12 1/8" 14 7/8' 1 1/2" CLEARANCE 38" 25 1 /2" 5 3/8" 15 1/8" Pag5P 69 Weights S.2© Ton Table 70-1 Factory Installed Options (FIOPS) Net Weights (Lbs)1,2,3 Accessory Model Accessory Number Weight High Efficiency Motors FIYHEMT001,002 15 FIYHEMT003-005 49 FIYHEMT006-008 36 Hinged Doors FIYHNGE001,002 10 FIYHNGE003-009 27 Powered Convenience Outlet FIYCOPO101-206 38 Through the Base Electrical FIYTBUE101-111 16 FIYTBUE201-216 23 Unit Mounted Circuit Breaker FIYUCB4015-4150 5 FIYUCB3175-3250 10 Unit Mounted Disconnect FIYUDC4150,6100 5 FIYUDC3250 10 NOTES: 1. Weights for FIOP accessories not listed are >5 lbs. 2. Net weight should be added to unit weight when ordering factory installed accessories. 3. See Table 69-1 for standard factory installed economizer, electric heater and oversized motor. Table 70-2 Maximum Unit Weights, Comer Weights (Lbs)'And Center Of Gravity Dimensions (In.) Tons Maximum Weights(Lbs) Corner Weights (Lbs)1 Center of Gravity (In.) Unit Model No. Shipping Net A B C D Length Width 3 WCD036 726 565 193 140 107 125 36 19 4 WC*048 759 586 196 144 112 135 36 20 5 WC*060 774 G02, 199 149 115 139 36 20 6Y4 WC*075 875 687 224 174 129 160 38 21 71/2 WC*090 908 719 248 181 131 159 38 20 10 WC*120 1479 1180 402 309 203 265 41 25 12Y2 WC*150 1743 1375 480 349 230 316 45 28 15 WC*180 1780 1412 501 356 231 324 45 28 20 WC*240 2375 1916 640 497 340 438 53 35 1. Corner weights are given for information only. 10-20 ton models must be supported continuously by a curb or equivalent frame support. *Indicates both downftow and horizontal units. A CENTER OF GRAVITY WIDTH CENTER OF GRAVITY Pag7P 70 Lennox Industries Inc. - Product Submittal Table of Contents System ID Qty Model Description RTU - 1,2,7 3 KHA060S4B PKGHP/5TON/BTO RTU - 4,5 2 KHA240S4M PKGHP/20TONBTO RTU - 6 1 KHA036S4B PKGHP/3TONBTO Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000541254 ROSS # 44 TUKWILA, WA Page 1of15 Last Changed: SAM WIESE Prepared On: 2014-11-11 Phone: 972-497-6301 Page 71 Lennox Industries Inc. - Product Submittal System ID: RTU - 1,2,7 Package Model: KHA060S4B Description: PKGHP/5TON/BTO HEATING PERFORMANCE Unit Type HP Output@Design H/E HighOutput System HeatOutput Packaged Heat Pump 59710 (Btuh) 47037 (Btuh) 106747 (Btuh) HP DesignTemp Electric Heater H/E Heat Rise 47.0 (°F) 15.0 (kW) 21.8 (°F) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Refrigerant Charge R-410A 10.9 13.0 5400 (W) 61500 (Btuh) 59000 (Btuh) 57800 (Btuh) 54787 (Btuh) 45084 (Btuh) 42071 (Btuh) 16 LBS. 0 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 1 1.00 (in.) 105.0 (°F) 80.0 (°F) 67.0 (°F) 58.5 (°F) 57.5 (°F) 59.8 (°F) 58.0 (°F) 12.0 (lb/hr) 12.0 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 2000 (cfin) 1.00 (in.WC) 0.96 (hp) 1.00 (hp) CAV Belt Drive 1269 (rpm) 1212 (rpm) 1548 (rpm) TotalStaticPress Wet Coil Static Press Electric H/E Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 1.28 (in.WC) 0.05 (in.WC) 0.18 (in.WC) 0.05 (in.WC) 4 20.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range-Nom Voltage 460V 3Ph 60 (Hz) 36.0 (amp) 40 (amp) 7.8 (amp) 11.2 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 2.1 (amp) 1.3 (amp) 405 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight Horizontal Supply Height Horizontal Supply Width 47.0 (in.) 83.3 (in.) 43.4 (in.) C796 -(l4) 19.5 (in.) 20.0 (in.) Horizontal Return Height Horizontal Return Width 11.0 (in.) 29.0 (in.) SOUND Outdoor Sound Rating 82 (db) Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000541254 ROSS # 44 TUKWILA, WA Page 2 of 15 Last Changed: SAM WIESE Prepared On: 2014-11-11 Phone: 972-497-6301 Page 72 Lennox Industries Inc. Product Submittal System ID: RTU - 1,2,7 Package Model: KHA060S4B Description: PKGHP/5TON/BTO SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor High Capacity Driers Separate Compressor and Controls Compartment High Pressure Switch (Manual Reset) Crankcase Heater Test Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details Limited warranty on Environ Coil System of 3 years Deep, corrosion resistant drain pan INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED CORROSION PROTECTION HINGED DOORS 2 IN MERV4 FILTER DISCONNECT - WEATHERPROOF GFCI - FACTORY INSTALLED/NON-POWERED SINGLE ENTHALPY ECONOMIZER BAROMETRIC RELIEF DAMPERS CONSTANT AIR VOLUME BELT DRIVE BACNET CONTROL MODULE BAROMETRIC RELIEF DAMPERS INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 97W23 17W45 14W40 53W79 41W34 3 3 3 3 3 BACNET SENSOR WITH DISPLAY STE-8001 FDHECKOOAN1 HORIZ. ECONO CONVERSION KT TIEH0150AN1G 15KW 460-3 C 1 SNSR43AP 1 SUP & RET SMOKE DETECTOR KT KISNSRI3A-1 LOW AMBIENT KIT - KH (A BOX) Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000541254 ROSS # 44 TUKWILA, WA Page 3 of 15 Last Changed: SAM WIESE Prepared On: 2014-11-11 Phone: 972-497-6301 Page 73 Lennox Industries Inc. - Product Submittal System ID: RTU - 1,2,7 Package Model: KHA060S4B Description: PKGHP/5TONBTO OUTDOOR AiR HOOD DETAIL W TN OPTIONAL (Horizontal Applications) ifrAl nrr J_ R AND BAROMETRIC RELIEF OAYPERS ECONOMIZER °MAINERS SUPPLY AIR DUCT 4 Iind Pcr dad) SULLY AIR OUTLET TOP il(EW RETURN MR DUCT TRANSITION (Fi■td fetrimind and bilked an urd) 19.12 ( 313ia + ) I (, II 41111 ItrII II; 11111 Illlll1I ' r l i l 1 1I I I III ntiused tattd 143(3i-14R 20 6ammdt■r ( ) 1 L .4 _, BACK VIEW 3 ■ FETURN Aft VIET OUTDOOR AIR IIMO furrified wtlh rxastmdter) 0 RETURN AR DUCT IRA! Findcslad • Mkt Na Wm! la + oximnu ele Ban manic %Mg Hod and Rabat, Air Ragr rGaa sets) d1ROilTIOC RUILEF MOOD OtENSIONS 1Mtl, -951I2 In. (932 mm) Negi.21a031mm)(CQ4,Ft90,QM, 040) 25n_(i15min) MO.OM Sea pnwiaus mg* 6r dads NOTE- fr i ertni srifigiadhstsq+ShEcanaciPe ngcim Morlfanial zceradar Con slag Kiti See OpinnstAmsmrYsSiats. BAR:METRO RELIEF HOOD (Fkrriatrdvrlh Ecomed r erd Field bandied an FEU #r6sc nir! Rahn At Duct) OUTDOOR AR 5.10 RETURN AR (140) DUCT TRANSRion (Find btriarYd and rumilidon urc!) H]FFZON 7+L •RE7 R N Atf"i OfErBiO 7i6 i 12/ 21:i (a1. 3dfi8 —I,, ,t r MR r40 RETURN MR DUCT U&ET flak! Fatrbrimi M d be Mood In aommodrea B:vneatc R■lar /bad rd Reran mliscidtrifikerral NOTE - Retms Air Ma Mid Tal3ftaivN1IMS1 be ebbf Nted. Modal No. A. in. mm 024, 030, 036, 048 060, 072 18-3/4 475 22-1/2 572 in. msl 11-3/4 299 15-3/4 400 Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000541254 ROSS # 44 TUKWILA, WA Page 4 of 15 718 (221 14iiE fRlAii al7C7 OPENING Virla 2CQQOIaZER INSTI UED 21 Ai (51) Erna VrEW Last Changed: SAM WIESE Prepared On: 2014-11-11 Phone: 972-497-6301 Page 74 Lennox Industries Inc. - Product Submittal System ID: RTU - 1,2,7 Package Model: KHA060S4B Description: PKGHP/5TON/BTO UNIT CLEARANCES - INCHES (MIN) OUTD —is. R AIRB HOOD .— D — A t Unit Clearance in. A mm B in. mm C in. mm D in. mm To Clearance Service Clearance 36 914 36 914 36 934 36 914 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. 1 Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000541254 ROSS # 44 TUKWILA, WA Page 5 of 15 Last Changed: SAM WIESE Prepared On: 2014-11-11 Phone: 972-497-6301 Page 75 Lennox Industries Inc. - Product Submittal System ID: RTU - 4,5 Package Model: KHA240S4M Description: PKGHP/20TONBTO HEATING PERFORMANCE Unit Type HP Output@Design H/E HighOutput System HeatOutput Packaged Heat Pump 220430 (Btuh) 94075 (Btuh) 314505 (Btuh) HP DesignTemp Electric Heater H/E Heat Rise 47.0 (°F) 30.0 (kW) 10.9 (°F) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Refrigerant Charge R-410A 10.6 13.0 20500 (W) 226000 (Btuh) 218000 (Btuh) 213500 (Btuh) 198505 (Btuh) 170800 (Btuh) 155805 (Btuh) 52 LBS. 0 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 2 2 1.00 (in.) 105.0 (°F) 80.0 (°F) 67.0 (°F) 59.7 (°F) 58.3 (°F) 61.4 (°F) 58.9 (°F) 40.3 (lb/hr) 40.3 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 8000 (cfin) 1.00 (in.WC) 5.25 (hp) 7.50 (hp) MSAV Belt Drive 960 (rpm) 850 (rpm) 1045 (rpm) TotalStaticPress Electric H/E Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness Number Exhaust Fans 1.11 (in.WC) 0.02 (in.WC) 0.09 (in.WC) 6 24.0 (in.) 24.0 (in.) 2.0 (in.) 2 ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range-Nom Voltage 460V 3Ph 60 (Hz) 102.0 (amp) 110 (amp) 33.4 (amp) 49.6 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 11.0 (amp) 5.2 (amp) 1500 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 91.1 (in.) 129.5 (in.) 54.3 (in.) 2298 (lb)'',. Downflow Supply Length Downflow Supply Width Downflow Retum Length Downflow Return Width 20.0 (in.) 28.0 (in.) 15.0 (in.) 60.5 (in.) SOUND Outdoor Sound Rating 93 (db) Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000541254 ROSS # 44 TUKWILA, WA Page 6 of 15 Last Changed: SAM WIESE Prepared On: 2014-11-11 Phone: 972-497-6301 Page 76 Lennox Industries Inc. - Product Submittal System ID: RTU - 4,5 Package Model: KHA240S4M Description: PKGHP/20TONBTO SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor High Capacity Driers Separate Compressor and Controls Compartment High Pressure Switch (Manual Reset) Crankcase Heater Test Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details Deep, corrosion resistant drain pan INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED CORROSION PROTECTION HINGED DOORS 2 IN MERV4 FILTER DISCONNECT - WEATHERPROOF GFCI - FACTORY INSTALLED/NON-POWERED SINGLE ENTHALPY ECONOMIZER MULTI -STAGE AIR VOLUME BELT DRIVE BACNET CONTROL MODULE INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 54W78 97W23 75W91 53W94 83W41 55W73 54W67 90W52 2 2 2 2 2 2 12 2 C1DAMP50C-1 GRAVITY EXHAUST BACNET SENSOR WITH DISPLAY STE-8001 C1PWRE11C-1G POWER EXHAUST 460-3 CIEH0300C21G 30KW ELECTRIC HEAT C1SNSR43C-1 SUP & RET SMOKE DETECTOR KT K1SNSR33CS1 LOW AMBIENT CONTROL 100929-03 FILTER - MERV 8 24 X 24 X 2 VFD BYPASS C 3/5HP V VOLT 3-10HP G J Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000541254 ROSS # 44 TUKWILA, WA Page 7 of 15 Last Changed: SAM WIESE Prepared On: 2014-11-11 Phone: 972-497-6301 Page 77 Lennox Industries Inc. - Product Submittal System ID: RTU - 4,5 Package Model: KHA240S4M Description: PKGHP/20TONBTO DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF Ibs. kg Ibs. kg Ibs. kg Ibs. kg in. mm in. mm KHA180 Std. Unit 385 182 466 220 602 284 497 235 59 1499 39-3/4 1010 KHA180 Max. Unit 492 232 548 258 648 306 582 275 56-3/4 1441 41-3/4 1060 KHA240 Std. Unit 423 199 497 235 665 314 565 267 58-1/4 1480 39 991 KHA240 Max. Unit 536 253 580 274 709 335 655 309 56 1422 41 1041 Std. Unit - The unit with NO OPTIONS. Max. Unit - The unit with ALL OPTIONS Installed. (Economizer. etc.) 90-1/8 (2289) CONDENSATE / DRAIN 5-3/8 (137) 0 0 0 (743) SIDE ELECTRICAL INLETS 91-1/8 (2315) � BASE END VIEW Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000541254 ROSS # 44 TUKWILA, WA Page 8 of 15 54-1/4 (1378) 51 (1295) 3-1/4 (83) AA —10 4-1/4 (108) 12-3/8 4 + 60-1/2 (1537) (314) 15 (381) BOTTOM RETURN t AIR OPENING BOTTOM SUPPLY 18 (457�)'AIR OPENINGS 12--3/8 28�� 28 1.4 (314) 7711) 4.1.. (71 )2 8) it DDI (114) EE- CENTER OF GRAVITY FF 4 (102) 4 BOTTOM POWER ENTRY (4)� 127 X 203 mm (5 X 8 in.) 102 TOP VIEW iz 13264) � (364) 4 ._ OUTDOOR III COILS 1. r� 00 �\ LIFTING HOLES \ FORKLIFT SLOTS (For Rigging (Front and Left Sides Only) Front and Back) 129-1/2 (3289) BASE r SIDE VIEW Last Changed: SAM WIESE Prepared On: 2014-11-11 Phone: 972-497-6301 BB CC Page 78 Lennox Industries Inc. - Product Submittal System ID: RTU - 4,5 Package Model: KHA240S4M Description: PKGHP/20TONBTO OPTIONAL OUTDOOR AIR HOOD DETAIL WITH STANDARD STATIC POWER EXHAUST FANS is (406) OPTIONAL OUTDOOR AIR HOOD (Field Instated) Required wth Economizer or Outdoor Air Demper 'OPTIONAL STANDARD STATIC POWER EXHAUST FANS H00D (Field Mutated) Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000541254 ROSS # 44 TUKWILA, WA Page 9 of 15 1 Field Installed in Return Air Duct for Horizontal Applications. HORIZONTAL BAROMETRIC RELIEF DAMPERS (Field installed in horizontal retum air duct adjacent to unit) 31-5/8 (803) j+ zs-tn (7as) 1 a a o v 4-7. 33 (330) I ie ii FRONT VIEW NOTE - Two furnished per order no. t NOTE - Opening size required in return air duct. SIDE VIEW Last Changed: SAM WIESE Prepared On: 2014-11-11 Phone: 972-497-6301 Page 79 Lennox Industries Inc. - Product Submittal System ID: RTU - 4,5 Package Model: KHA240S4M Description: PKGHP/20TONBTO UNIT CLEARANCES - INCHES (MM) Unit With Economizer AIR MOOD Note: 240-300 sizes shown 1 Unit Clearance A B CD Top Clearance in. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 36 934 66 1676 Unobstructed Minimum Operation Clearance 45 1143 36 914 36 914 41 1041 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000456030 ROSS # 44 TUKWILA, WA Quote: 4000541254 ROSS # 44 TUKWILA, WA Page 10 of 15 Last Changed: SAM WIESE Prepared On: 2014-11-11 Phone:972-497-6301 Page 80 Lennox Industries Inc. - Product Submittal Table of Contents System ID Qty Model Description RTU-6 1 KHA036S4D PKGHP/3TON/BTO Project: 3000442718 ROSS # 44 TUKWILA, WA RTU-6 Quote: 4000525753 ROSS # 44 TUKWILA, WA RTU-6 Page 1 of 6 Last Changed: SAM WIESE Prepared On: 2014-08-19 Phone: 972-497-6301 Page 81 Lennox Industries Inc. - Product Submittal System ID: RTU-6 Package Model: KHA036S4D Description: PKGHP/3TONBTO HEATING PERFORMANCE Unit Type H/E HighOutput System HeatOutput Packaged Heat Pump 19235 (Btuh) 19235 (Btuh) HP DesignTemp Electric Heater H/E Heat Rise 47.0 (°F) 7.5 (kW) 14.8 (°F) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Tube/Fin Refrigerant Charge R-410A 10.9 13.0 3300 (W) 37100 (Btuh) 35600 (Btuh) 35000 (Btuh) 33411 (Btuh) 27650 (Btuh) 26061 (Btuh) 12 LBS. 8 0Z. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB 1 1 1.00 (in.) 105.0 (°F) 80.0 (°F) 67.0 (°F) SUPPLY FAN PERFORMANCE ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type 1.00 (in.WC) 0.50 (hp) 0.50 (hp) CAV Direct Drive TotalStaticPress Wet Coil Static Press Electric H/E Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 1.12 (in.WC) 0.02 (in.WC) 0.06 (in.WC) 0.04 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range-Nom Voltage 208V 3Ph 60 (Hz) 39.0 (amp) 40 (amp) 10.4 (amp) 15.2 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 3.1 (amp) 1.7 (amp) 250 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight Horizontal Supply Height Horizontal Supply Width 47.0 (in.) 83.3 (in.) 36.4 (in.) (720 (1b) 19.5 (in.) 20.0 (in.) Horizontal Return Height Horizontal Return Width 11.0 (in.) 29.0 (in.) SOUND Outdoor Sound Rating 75 (db) Project: 3000442718 ROSS # 44 TUKWILA, WA RTU-6 Quote: 4000525753 ROSS # 44 TUKWILA, WA RTU-6 Page 2 of 6 Last Changed: SAM WIESE Prepared On: 2014-08-19 Phone:972-497-6301 Page 82 Lennox Industries Inc. - Product Submittal System ID: RTU-6 Package Model: KHA036S4D Description: PKGHP/3TONBTO SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor High Capacity Driers Separate Compressor and Controls Compartment High Pressure Switch (Manual Reset) Crankcase Heater Test Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED 2 IN MERV4 FILTER GFCI - FACTORY INSTALLED/NON-POWERED SINGLE ENTHALPY ECONOMIZER BAROMETRIC RELIEF DAMPERS CONSTANT AIR VOLUME DIRECT DRIVE BAROMETRIC RELIEF DAMPERS INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 96W14 97W24 17W45 14W35 53W79 20W15 EOC 1 1 1 1 1 1 KOCTRL31A-1 BACNET A BOX BACNET SENSOR W/O DISPLAY STE-6011 FDHECKOOAN1 HORIZ. ECONO CONVERSION KT T1EH0075AN1Y 7.5KW 208/230-3 C 1 SNSR43AP 1 SUP & RET SMOKE DETECTOR KT T2DISC080A-1 80A DISCON TC/TH SHORT Third Party EOC & GUIDED SETUP Project: 3000442718 ROSS # 44 TUKWILA, WA RTU-6 Quote: 4000525753 ROSS # 44 TUKWILA, WA RTU-6 Page 3 of 6 Last Changed: SAM WIESE Prepared On: 2014-08-19 Phone: 972-497-6301 Page 83 Lennox Industries Inc. - Product Submittal System ID: RTU-6 Package Model: KHA036S4D Description: PKGHP/3TONBTO DIMENSIONS - INCHES (MM) Model No. CORNER AA Base Ibs. kg WEIGHTS Max. Ibs. kg BB Base Ibs. kg Max. Ibs- kg CC Base Ibs kg Max. Ibs. kg DD Base Ibs. kg Max. Ibs. kg CENTER OF EE Base in. ntrn GRAVITY Max. in. mm FF Base in. mm Max. in. mm 024 92 42 116 53 112 51 131 59 180 82 211 96 148 67 186 85 38-12 978 40 1016 18 457 18 457 030 92 42 116 53 112 51 131 60 180 82 211 96 149 68 187 85 38-12 978 40 1016 18 457 18 457 036 93 42 116 53 112 51 132 60 181 82 212 96 149 68 187 85 38-12 978 40 1016 18 457 18 457 048 96 44 120 55 117 53 136 62 188 86 219 100 155 71 194 88 38-12 978 40 1016 18 457 18 457 060 115 52 138 63 140 64 157 71 226 103 252 115 166 84 223 101 38-12 978 40 1016 18 457 18 457 072 160 73 185 84 180 82 208 94 233 106 269 122 207 94 239 108 46-1/4 1174 46-1/4 1174 20-1/2 521 20-1/2 521 Base Una - The una with standard heat exchanger NO OPTIONS. Max- Una The unit wall ALL OPTIONS Installed. (Economiser, etc.) 5-5/8 (143) 29 (737) 47 ( 192) i BASE r 45 (1143) 100 1 1 1 1 0` 1 - 47 (1192) ,( BASE END VIEW Project: 3000442718 ROSS # 44 TUKWILA, WA RTU-6 Quote: 4000525753 ROSS # 44 TUKWILA, WA RTU-6 Page 4 of 6 3-1/ DD • y i6•i/4,r,� 18 11 (413) (457 1 (279) 1 BOTTOM RETURN AIR OPENING BOTTOM SUPPLY/ AIR OPENING 5(102) f 20 (508) 6-5 8 _Le (168) \ CENTER II, !.` ' OF !1: GRAVITY A `I,25.3/4 (654) 024 thru 060 r FF4`C J 9-1/2 (241)r38-3/4 (984) 072 26-1/2 BOTTOM (673) CONDENSATE OUTLET BB CC EE BOTTOM POWER ENTRY 3 X 8 (76 X 203) TOP VIEW (Base) Oriw lnul UZ4 NW wU 96-1/4 (2445) 072 +' i CONDENSATE OUTLET (EITHER SIDE) I \ i (40) ELECTRICAL INLET </ , I II 'I II 111. 2(89) 100 ( 1 L I 26-1/2 ,0CI OF TING HOLES (673) (For rigging) SIDE VIEW 11 (25) ltl-I1 1153/S i IliI IIIII1 I, : I 1 11 II 11111 II' (737 00 0 1) ) FORKLIFT SLOTS 5-1/2 HORIZONTAL HORIZONTAL 5-1/2 (Front Back and (140) SUPPLY AIR RETURN AIR (140) Sower End) OPENING OPENING (WithoutEcanomaer) BACK VIEW Last Changed: SAM WIESE Prepared On: 2014-08-19 Phone: 972-497-6301 Page 84 Lennox Industries Inc. - Product Submittal System ID: RTU-6 Package Model: KHA036S4D Description: PKGHP/3TONBTO OUTDOOR AIR HOOD DETAIL. WITH OPTIONAL IEC (Horizontal Applications) SUPPLY Ail DUCT paid Pro*loll t412ER Ai40 IIARO METRIC Raiff DAMPERS R5TUF 1 MR DUCT TRANSITION Mold larizabi l and SUPPLY radeibdonoril) 111 OUTLET TOP VIEW µg6) pg)) 1iI�III I. 11111: I I Ir,l1 1II1I 1111111111 111 I Ill, IIII r— -- op artna nal used in H)R2 Ai2 ApRaoawmsTrait EmMatlearc I() 1 rl U lam �L Q 0 BACK VIEW RETURN AIR PRET OUTDi ORAR HC fum6ttrd;t t Fwu 11 rrl 5.12 RETURN AR (140) DUCT TRAtis 1EN (f1Yd.bbiarbd and installed an urn) RETAIN AR DUCT poll Filastvrd- Most b4=HIiD amm+adar Brminhic RaMaf Nmd rid Rego Mr Rar}tidners) MARROAETRiC REEF HOOD d1iBISIONS Vizier •31512 h 002mm) ilelgtt 21 it 039 mn)(024, 030, Me, 1:1441) 25 n. 0135 nun} Pik 072) Sao irialcus pogo for dards. NOTE. Hanzmtd aratiiniaimswib Emostim m to Horizontal ` onsn+sr Conversion Kk Saa OsfartsNlmasearris arbin. BAROMETRIC RELEF HOOD (Furrist.d nth Ecaronizar alai Add IreWlad m Foil !distorted Ream At OW* OUTDOOR EtHAUST AIR RETURN All oticr INLET field Farmlid - Huai ba amid la aaosatodo/o Bartrnatic Role! thud alai Rolm ANRagionrria) NOTE • Retnrn Air Oud. a d TeMORait mud Beett.inaded, 2.114 (57) LE i92) t A 9-i.. Model Ho. A ir>V mm 024, 030, 036, 048 060, 072 18-3/4 476 22-1/2 572 B in. mm 11-3/4 208 15-3/4 MO Project: 3000442718 ROSS # 44 TUKWILA, WA RTU-6 Quote: 4000525753 ROSS # 44 TUKWILA, WA RTU-6 Page 5 of 6 7,1 2.1At .ate RETURINAli DUCT c*eWIG wri a +DNDA IZER 111€31AltED END VIEW Last Changed: SAM WIESE Prepared On: 2014-08-19 Phone: 972-497-6301 Page 85 Lennox Industries Inc. - Product Submittal System ID: RTU-6 Package Model: KHA036S4D Description: PKGHP/3TON/BTO UNIT CLEARANCES - INCHES (MM) OUTDOOR AIR HOOD B .-111P D --► A 1 Unit Clearance A in. mm B in. mm C in. mm D in. mm To Clearance Service Clearance 36 914 36 914 36 934 36 914 Unobstructed Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. 1 Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required dearance for proper unit operation. Project: 3000442718 ROSS # 44 TUKWILA, WA RTU-6 Quote: 4000525753 ROSS # 44 TUKWILA, WA RTU-6 Page 6 of 6 Last Changed: SAM WIESE Prepared On: 2014-08-19 Phone: 972-497-6301 Page 86 TOP FLANGE DIM: 1 1 /2" m 2 0Q0 0, CHANNELS:16 GA CO a SHELL:16 GA BURGLAR BARS @ 12" O.C. IN S/A AND WA J -eon r\ • s a x -14 w 1- z w Z T/K-SERIES/LGH-LCH 024-072 OLD UNIT:TRANE SEE ABOVE ROLLS OF GASKET:2 TAG: RTU-1 ♦ tur N. g N N 10 i w �D 2 • 20 X co M co ,Ngl co O fr. Milo 1 Urgi cooeEt. 3 0 G O. 1 ci 0 O 3 v 01 0 ro n w SP I TOP FLANGE DIM: 1 1/2" a 0 0 W O C43 0 vs co 0 re co O CHANNELS:14 GA co 0 J J W co BURGLAR BARS (it 12" O.C. IN SSA AND R/A 1' .W9 Z 3SV9.9/£ OS 'Q'0.1ti \\\ \ \ • • ♦ \ • • \ • • • ♦ ♦ • c) DRAWN BY.: SLR T/K-SERIES 024-072/LGH-LCH 036-072 OLD UNIT:TRANE TCD-WCD 036A-060A NOT YCD ROLLS OF GASKET:2 TAG: RTU-2 of 'moo 0 to CO to w to C s l iJI 04 0 • Eci Z� 0 o Zi`dg giQ if 0) N I^ 8 Qv, A o' 0. cle c l Ita 83 mom goat TOP FLANGE DIM: 1 1/2" 0 0 LC) 9 N cal u) ce co 0 U CHANNELS:14 GA V co a LL, co BURGLAR BARS @ 121 O.C. IN SIA AND RIA 39V8 2/1 aL Z � .Z/L i►L .W I CL .Z/L CZ St .L -m .a/s ze .afo.als se .e/LL cn >- N L/T/K-SERIES/LGH-LCH 156-360 OLD UNIT:TRANE SACA/SACC/SFCA/SFCB C15/17 ROLLS OF GASKET:2 LA 1 cc do o— M LLJ n 20 H CO //�/� 1- r 0 rtg 04 CV I Z! w Ca IIg (D 1- 9 u z e bot m LL0 r. 0 2 0 a a. CO 03 O v g cq M2clei 48 Mgu' 2 TOP FLANGE DIM: 1 1/2" 0 N N C7 cta 0 V —J W Q U co Z a J —J W 2 0 ad. z ci 0 cow le— .9►S Ez 3SV9.9►S 16 .�►109 .17►EL1 ,r .6 Z.919 iZ --1 :......t O'1.9/S Z9 '0'4.9►5 59 .\ \ c \7 \� \\` \� \\ \\ rQ \ ♦ ♦ \% \\ \ \ \. ♦ \\ \ \ \ \ \ \ \ Ir pp, i - c _� 1 .8/S Z .919 Z il .9/E 99 a L/T/K-SERIES/LGH-LCH 156-360 OLD UNIT:TRANE SAHB/SEHB 200-250 ROLLS OF GASKET:3 TAG: RTU-6 CO i APPROXIMATE WEIGHT:485 LBS. fi v O m ro t r co ai as cis 2 0 m 2 Q 0 0 w LC) 0 rn CD 0 0 co w 0 0 CHANNELS:18 GA BURGLAR BARS It 12' O.C. IN S/A AND R/A .9LJ6Z '----- .ZJL K t 3SV9 .ZS .9N9L tiZ 'fl'0 .Lti 1 • .LL—? .91J6 Z .ZJL OZ co .717 a 2 a U v co N CO U C7 a NEW UNIT:LENNOX T/K-SERIES 024-0721LGH-LCH 036-072 ENERGENCE OLD UNIT:LENNOX SEE ABOVE ROLLS OF GASKET:2 TAG: RTU-7 0 • a I N 2 v 0 a 40 '4 co a x U U w J Z 6 0 m a cg,� x 0 z w W z� z m 0 �C+ 0 0 0 t0 u 0 b 0 0 4z PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0135 DATE: 10/13/15 PROJECT NAME: ROSS STORE SITE ADDRESS: 17672 SOUTHCENTER PKWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: A(' Building Division Public Works ❑ P('M t \VQ\►�i k W° Fire Prevention 1111 Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) DATE: 10/15/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 11/12/15 Approved with Conditions ❑ Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 WOLFER'S INC Page 1 of 3 Home Inicio en Espanol Contact Search L&I A-Z Index Help My Secure I &l Safety Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries WOLFER'S INC Owner or tradesperson Principals Christin, John Paul, PRESIDENT Nelson, Cynthia Louise, SECRETARY Christin, Karen, MEMBER (End: 10/16/2015) Doing business as WOLFER'S INC WA UBI No. 600 475 077 1365 N FRONT WOODBURN, OR97071 503-981-4511 Business type Corporation Governing persons CYNTHIA NELSON JOHN CHRISTIN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. WOLFEI*916P6 Effective — expiration 10/26/2009-10/26/2017 Bond ................. Contractors Bonding & Insurance Co Bond account no. ph1661 $12,000.00 Received by L&I Effective date 01/10/2013 01/09/2013 Expiration date Until Canceled Bond history Insurance ............................ Continental Western Ins Co $1,000,000.00 Policy no. CPA601431425 Received by L&I Effective date 06/26/2015 07/01/2015 Expiration date 07/01/2016 Insurance history https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600475077&LIC=WOLFEI* 916P6&SAW= 10/29/2015