HomeMy WebLinkAboutPermit M15-0138 - COSTCO- REFRIGERATION CASESCOSTCO WHOLESALE 400 COSTCO DR M15-0138 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2523049057 Permit Number: 400 COSTCO DR BLDG Issue Date: Permit Expires On: COSTCO WHOLESALE M15-0138 11/16/2015 5/14/2016 Owner: Name: Address: Contact Person: Name: COSTCO WHOLESALE 999 LAKE DR ATTN: PROPERTY TAX #06, ISSAQUAH, WA, 98027 BILL ZORNES Address: 19430 68TH AVE S , KENT, WA, 98032 Contractor: Name: KEY MECHANICAL CO OF WA Address: 19430 68TH AVE S STE B , KENT, WA, 98032-1193 License No: KEYMEW*240NZ Lender: Name: Address: Phone: (253) 872-7392 Phone: (253) 872-7392 Expiration Date: 4/1/2017 DESCRIPTION OF WORK: REMOVE (2) EXISTING 12' REGRIG CASES. INSTALL (2) NEW 12' REFRIG CASES Valuation of Work: $11,500.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $350.42 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: Date: 1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this developmen p. jt and agree to the conditions attached to this permit. Signature: Print N Date: /1A /`- This permit shall ecome null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 0705 0701 MECHANICAL FINAL REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit issued by the City of Tukwila the job site at the time of inspection. CITY OF TUKW. 1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. IV t, t "✓ ' \if6 Project No. ii'W^ Date Application Accepted: 10 tit)\ t Date Application Expires: 141 } Re (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 4.6 La ✓'TG 6 b(z.1 Tenant Name: r S i Gh tit en S I L PROPERTY OWNER Name: GQ i e. a \1%f-1bL S 4.1— ---- Address: ci L .6, (L. bt . City: 1 z-7 65 CA d4-1 State: \VA Zipci4;02 T CONTACT :PERSON — person receiving all project communication Name: �� L.L. . !O t2 l+....l_ Address: l q 4 ,c3 ' 6 6 Qve .- y, , City: khl``' State: wk.. Zip.e7032 Phone:25, -v?Z' 73eflax:S3 ...oil.... i. 1$ Email: 'gC>t.z WEST Viv`1 1 ( 14 <St.(t eA L r e-O King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes ❑.. No MECHANICAL CONTRACTOR INFORMATION Company Name: k,..c. lei-G u .dktr t e A L. Address: City:ILEw` State: va Z o ,_ Phone755 _ Fax is -�3� z is3 •61 z � `i 3c, g Contr Reg No.: t�W4t24Gu7. Exp Dateq /mil — / Tukwila Business License No.: Valuation of project (contractor's bid price): $ 1 Ss Describe the scope of work in detail: (zet.'t 'Jre (2> 1'r xt S j I hl C,� f VLF(Zi . GdSI� s CZ) 1^1 --•kv 12- _ Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: H:Wpplications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type I Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heatlrefrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING R OR AU HORIZED AGENT: Signature: Print Name: 41 -t— —U IZ1,4 Date: 1O/(to, ij Day Telephone: 2 7� ' i3f Z —1"- 2- Mailing Address: City State Zip H:\Applications\Forms-Applications 0n Line\2011 Applications\1vlechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PermitTRAK PAID $350.42 M15-0138 Address: 400 COSTCO DR BLDG Apn: 2523049057 $350.42 MECHANICAL $336.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $237.05 PLAN CHECK FEE R000.322.102.00.00 0.00 $67.39 TECHNOLOGY FEE $13.48 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6450 R000.322.900.04.00 0.00 $13.48 $350.42 Date Paid: Friday, October 16, 2015 Paid By: KEY MECHANICAL Pay Method: CHECK 2688 Printed: Friday, October 16, 2015 10:59 AM 1 of 1 tiSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 T 6 /�/�DA, Tyke of InspeO-A gi / -(Prof_ A�Jdr`` ...60 O 5.4 Date Called: Special Instructions: ,,. �� Date Wanted: 1 491 m. Reque er /5,�lI- 2'aj—A)e.S Phone 1(7 `1 /3 /�" proved per applicable codes. COMMENTS: Corrections required prior to approval. inspector: ✓` REINSPECTION FEE REQUIRED. Prior to next inspection, ee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: a / i /i yype of In_suction: i / Address: QM a i*C3 D~ At C4 Date Called: Special Instructions: Date Wanted: ' :m ait/2s P. Requester: Phone No: C Approved per applicable codes. COMMENTS: Corrections required prior to approval. Allff *A wisrvil a do Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ?ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0138 PROJECT NAME: COSTCO WHOLESALE SITE ADDRESS: 400 COSTCO DR X Original Plan Submittal Response to Correction Letter # DATE: 10/20/15 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: C 10-L3-15" Building Division II Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/20/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/17/15 Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (i.e: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff initials: 12/18/2013 KEY MECH CO OF WASHINGTC 'T Page 1 of 2 Search L&I Hone lnicio en Lspaiiol Contact A-Z Index Help My Secure L&i Safety Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries KEY MECH CO OF WASHINGTON Owner or tradesperson HEISLER, ROBERT L Principals HEISLER, ROBERT L LEONARD, FRANK W SANDAHL, LEE F WA UBI No. 600 196 154 19430 68TH AVE S STE B KENT, WA 98032 253-872-7392 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ......................................................:................. Meets current requirements. License specialties GENERAL License no. KEYMEW*240NZ Effective — expiration 08/09/1976— 04/01/2017 Bond ................. LIBERTY MUTUAL INS CO Bond account no. 023011682 $12,000.00 Received by L&I Effective date 03/23/2009 04/01/2009 Expiration date Until Canceled Insurance ....................._ Hartford Fire Ins Co Policy no. 52UENOE0154 $1,000,000.00 Received by L&I Effective date 03/27/2015 03/31/2013 Expiration date 04/01/2016 Insurance history Savings .................. ..... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ......................................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600196154&LIC=KEYMEW*240NZ&SAW= 11/10/2015 1 +-----* TEEL . __ -y- -- F-.I " m= =T= _= I I F + I L 1 1 1 1 1 1 1 1 F-+-I-+++++ 1 1 1 1 1 T -1 I 1 I 1 1 I 1T- 1' 1 1 -1 1 1--=-1 I 1 1 1 1 1 1 1 1 1 1 I ▪ T T T T T T T T T 1 1 1 1 1 1 1 1 1 1 1 1 I F- + + + + + + -1- + + -I- + -I I L- 1 1 III I 1 J I L. 1 -I__ 1 _L- I 11 1 J_ J 17 CAKE Ti! PROJECT DATA EXISTING PROPOSED N v #6 TUKWILA, WA ♦ v ♦. ♦ L J ' Z-- I 1 I I I I I I T L _ -Tv mx '- I- -c: _: vic.== =m - L -.1.- _ mod, _�_ _ =J, - -1 _ _J P' = I -_ 1 to _ EXIST. JEWELRY 1 11111 �. 1 L _L -L.- 1 _L 1 I y 11111111 + + + + + + + L 1 1 _L_ 1 1 1 o===__=L___J_ 1 L _L - __ _1_ __ _1_ -- _1_ _ _1_ __ _1_ _- -.L- __ _-L- __ _.L _ F - I I LJ 84'_3• _= :t_ _= �= s= _�_ __ =fie =_ _�� .�,= x= `�` __ __ _�_ r-r1 -e i I 0 0 I I A II H-I--B 1 I 0 C 1 1 II 0 i REFRI4E10'1 P4TF4Md �4SOVE I 0 0 L -Li_J A' 00 I 1 O0 0 y0 1 11 0 1 1 B A NV II � _11_-J•I f-T-1 { rLr { rT I 11 1 I 10 0 I 11 0 I I0 1 B 1 I R I--HI-ll E+R--9 I I A 1 - 11 A 0 11 1 R II - I I 11 0 L _ 1 _ J L _ 1 _ J t- -- _*- -_ SE 18' f + 1 11111 T T T I I 1 1 1 1 1 1 I I I I I I I I I I I I ++++ I 1 I I I I I I I I ▪ 11111111-1-11111 I I I I I 1 1 I 1 11 I 1 I 1-+++++++—++++++ -0- 1 I 1 I -4-- 1 1 I I. T T I I I I I I I I F-+--- , + + -4- -4- 1 1 1 1 1 J_ T T 1 1 + + + -I-- 1 I 1 1 1 1 I 1 1 1 1 1 I 1 1 1 1 1 1 J r T T T T T T T T T T T T T T T T I 1 1 1 1 1 1 I 1 1 1 I I 1 1 1 1 h- 1 1 I I I -4-1 I 1 1 1 1 1 1 1 I 1 1 1 I 1 r T 1 1 I I 1 I I 1 I- I I 1 1 I I- 1 I +-4-++=1=++-I L 1 1 1_I_ 1 1 1 1 1 1 1 1 1 J T T T I 1 1 1•1 1 1 1 I --I- i 1 J T T I I I I I I I I I I I 1 I I I I I I I I I I 1 I r T T T T T T T - T T T T T T T T T T -r T '1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 +++++++—+ Fes'++++++4-+++ r T T T T T T 1 1 1 1 1 L 1 1 1 1 1 1 I I I F ++ L 1 1 T T T T T T T T T T T T T + 1 I 1 I 1 1 1 1 1 1 1 I 1 1 1-- 1 y 1 1 1 1 1 -1- 1 I I I I I I I I I I I I I I I I 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 I I 1 I 1 I I I I I 1 1 1 1 1 I I 1 I I-+++++++—++-4--+- ++++ I 1 1 1 1 1 1 1 II 1 1 1 1 1 1 1 1 1 1 1 I TT MAIN SALES 1 I -4- -4- -4- + H- im I + 1 1 T T -T- 1 I I I I I I 1--+++++++-++ f T l f T 1 f--F l L_1_J L_1_J I I I 1 1 I I I I I I I I I I I T T T T T T T T T T 1 1 1 1 1 1 1 1' I + + + + + + + + --4- -T- T -T- -1- + + I I I f T-1 I I I 11 I I I I 1 I II I II I 1 11 I I II I I I II 1--1-1--1 I 11 L_1_J II IAA IA4 IA 54) REACH4N ()CMSIAA Y/ AAA T T T T T T T + + + + + + + 1 1_ I I f T-1 III I I I I L_1_J I I L J o\ • 00 v en to 'i -=A �IF - rn L_JIL_J + + + -I- L- -1- JI_ _L -4- -4- 1 1 J_ + -I I _I, I I I I EXIST. PAM 1-' — HEARING AID SSTEEL m-_::*::: =*_ =s `x::::*: a� L_L SSTEELd, =-.=._�_===1.==-= ====-L========= SS�EEL�= __ _�• ee _J.. and = _ __ . __ __ JP— L 1SSTEEL f T 1 L 1 9'HT. FIRE PROTECTION STAND PIPES FIRE HYDRANT GAS VALVE r• ELECT. _,Lrinx COSTCO WHOLESALE CORPORATION 999 LAKE DRIVE ISSAQUAH, WA 98027 T: 425.313.8100 www.costco.com COMPACTOR WATER METER WATER VALVE )ALFR / :OMPACTOR ROOM 1 1 -a - 164'a' STORAGE Op i7 (13 _=aae==a� a==X`=__X_ _1_J f T 1 F-+-i I II L _ 1 _ J (9)' C_N F 1 LJ I 13'a• L_J I 1 -+-1 1 L_J Ma III MID NM SHOP-1N DAIRY 7-1 11 :lc En POS COOLER POS FREEZER TRANS. PTM-r II II 11 I I ci II II II II • • cs POS FREEZER II 11 11 11 SHOP -IN PRODUCE anu NMI ell INN I NEW ANTHONY • 1-1 r====9P====11= POTATO GlikIP AREA TELEPHONE CLOSET BATTERY CHARGER COOLER MAINTENANCE COOLER DFFICE -US DFFCE BREAK ROOM MEN RESTROOM kr 04 to ral BAKERY COOLER LINE-UP MEAT DELI 108' M-1 40' M-1 -:N7,PROJECT SCOPE DEMOLISH: 1. DEMOLISH 24' M-1 DELI LINE-UP CASES 2. PARTIALLY DEMOLISH DELI WALL TO ALLOW FOR NEW ANTHONY WINDOWS WINE WINE INSTALL: 1. INSTALL NEW 24' 2-TIER DELI LINE-UP CASES 2. INSTALL NEW ANTHONY WINDOWS NOTE: REVISIONS EXISTING CONDITIONS TO BE FIEN9, 0 RiilworK withOu prior approval of mshall. be made to the scope 11 it - MEAT PREP. RTV DELI PREP. • 80 VERSTOCK— DELI COOLER . ii11111•11i11111-i 11 OFFICE EXIST. EXIST. SCRUBBER ORASF TORAGE PhIrribing TuAwila Li REFRIGERATION MECHANICAL ROOM TRANS. Plan review approval is subj ct to errors and omissions. Approval pc, fmnstruction doc ments does not authorize the violation of any adopted , or ordinance. Receipt REVIEWED FOR CODE COMPLIANCE APPROVED City of Tukwila BUILDING DIVISION CiT'l OF TUKWILA OCT 1 6 2015 PERMIT CENTER GENERAL NOTES: 1. REFRIGERATION CONTRACTOR TO FURNISH STEEL BUMPERS. BUMPERS TO BE INSTALLED IN FRONT AND/OR NEXT TO ALL CASES EXCEPT FOR BAKERY CASES. SEE DRAWING DETAILS. 2. SEE ARCHITECTURAL DRAWINGS FOR CURBS IN AND/OR AROUND REFRIGERATED BOXES. 3. COLUMNS TO BE WRAPPED WITH STAINLESS STEEL FROM FLOOR TO CEILING. FURNISHED BY PANEL MANUFACTURER, INSTALLED BY REFRIGERATION CONTRACTOR. SEE PANEL DRAWINGS FOR ADDITIONAL DETAILS/REQUIREMENTS. 4. ALL WALK—IN COOLER AND FREEZER EVAPORATIVE COILS LOCATED AS SHOWN ON PLANS. 5. ALL 2'-0" CLEARANCE ABOVE NOTED INTERIOR COOLER HEIGHT FOR STRUCTURAL STEEL. 6. CLOSURES/FILLERS FOR ANTHONY WINDOWS TO BE AUTO BRIGHT. PROVIDED AND INSTALLED BY REFRIGERATION CONTRACTOR. 7. SALES FREEZER #1 TO HAVE POWEREDAIRE AIR DOOR, MODEL: ETD 2-84 FURNISHED BY KYSOR//WARREN AND INSTALLED BY REFRIGERATION CONTRACTOR. 8. SHOP —IN PRODUCE. TO HAVE HCR AIR CURTAIN, MODEL: HCR AC —CS. FURNISHED BY PANEL MANUFACTURER AND INSTALLED BY REFRIGERATION CONTRACTOR. 9. SEE COSTCO SPECIFICATION FOR REQUIRED MATERIALS AND METHODOLOGY FOR SANITATION COMPLIANCE IN PREP AREA. (E) BAKERY (E) BAKERY CASE B20 (E) BAKERY COOLER 0) (E) BAKERY COOLER A9 (E) BAKERY FREEZER FRESH AREA PLAN (CONT.) SCALE:1/8" = 0" EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS —BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS .PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. EACH CONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF. ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO FAMILIARIZE THEMSELVES WITH THIS KNOWLEDGE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY TO PERFORM THE WORK AND ENSURE THE EQUIPMENT OPERATES PROPERLY. ADDITIONAL COMPENSATION SHALL NOT BE PERMITTED DUE TO CONDITIONS RESULTING FROM FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. REFRIGERATION CONTRACTOR TO ADHERE TO ALL EPA GUIDELINES. • 50'-n" - (822) (E) (4) BMG520 1 �N II I • I �' m v i N PAS (E) COOLER iIP v N IP 1 1 I -- A61 ---�-- I 1 I o "' ltl SHO"—IN MET Q � I n nIP I¢ 1 a I 1 a z1 COO ER • I L J IP ' 16'-4" - o I� (E) 8'-4" NHMGHP 5/D DELI (E) 20.-4" 05E M/D DELI - ■I 1 B21 A8 A8 J o Im I I � 1 • (E) (4) MK26-206KGE I 1 L'I w (E) 24'-4" NHM I. II O � � , POS FREEZER #1 to I Nife MEAT (E) COOLER r} I •I I L v (-, O I J U ;I- IV',-i , • NrgirN Niv'lliN'"li', Nrirqi N-Nr"*"' NryfliJ• I A7 (A7) ir N a I • _ �\\� �sl- �� - -(- —mot —\A A z®� \ B76 a (Al2) r1 (— 1 M v I (E) MEAT PREP ,I ,o,l � GO v POS E FREEZER #2 V V ° I I O n 0 m n Al2 • I L Q S J v U 2 J I � (E) (3) LFA-190AE I - - e 1 I + _ /\F?EJ\ DF \ O F I 0�� (E) (2) LFA-190AE ■ \ z E ® �1i DELI PREP ® 038 O e— ' z `I� I �JI/D DELI ISLAND 0 o � � /0 0 0 Ll ce) 5 (E) 56' DX6LN z 0 ....J(E) N v 1is I ti col ROTISSERIE OVERSTOCK DELI COOLER • Lo • . ®ORD ---- (C39) 41111) CHICKEN �� (E) (2) ITG-24-325 • r • I c OM J L J DEMOLISH: v L 1. DEMOLISH 24' M-1 DELI LINE-UP CASES POINT OF SALES PLAN 2. PARTIALLY DEMOLISH DELI WALL TO ALLOW FOR I SCALE:1/8'=1'-0" NEW ANTHONY WINDOWS FRESH AREA PLAN INSTALL: SCALE 1/8"=1'-0" 1. INSTALL NEW 24' 2-TIER DELI LINE-UP CASES 7 INCTAI I NFW ANTHnNY WINfOWC 1 COSTCO WHOLESALE COP_OATIO\ 999 LAKE DRIVE ISSAQUAH, WA 98027 T: 425.313.8100 www.costco.com #5 CORPORATE RIDGE PKWY. COLUMBUS, GA 31907 Tel: (706)568-1514 Fax: (706)565-1723 HEATCRAFT Worldwide Refrigeration INTEGRITY, COMMITMENT TO STAKEHOLDERS, AND PASSION FOR EXCELLENCE CONTACT INFORMATION SYSTEMS SALES JAY MELANCON C — (706) 536-9477 SYSTEMS ENGINEERING DEPARTMENT CONNER MEADOWS (800) 866-5596 EXT. 2734 JAMES BIBLE (800) 866-5596 EXT. 2709 2-TIER DELI REMODEL O KYSOR/WARREN: All rights reserved. No part of this document may be reproduced. In any form or by any means without the expressed written consent of Kysor/Worren. / DATE DESCRIPTION DATE ISSUED: 10/9/2015 DRAWN BY: L.SILVIS REFRIGERATION EXISTING FLOOR PLAN WITH AREA OF WORK ER1 REVIEWED FOR ODE COMPLIANCE APPROVED NOV 062015 City of Tukwila BUILDING DIVISION RECE.NED CITY OF TUKWILA OCT 1 6 2015 PERMIT CENTER GENERAL NOTES: 1. REFRIGERATION CONTRACTOR TO FURNISH STEEL BUMPERS. BUMPERS TO BE INSTALLED IN FRONT AND/OR NEXT TO 'ALL CASES EXCEPT FOR BAKERY CASES. SEE DRAWING DETAILS. 2. SEE ARCHITECTURAL DRAWINGS FOR CURBS IN AND/OR AROUND REFRIGERATED BOXES. 3. COLUMNS TO BE WRAPPED WITH STAINLESS STEEL FROM FLOOR TO CEILING. FURNISHED BY PANEL MANUFACTURER, INSTALLED BY REFRIGERATION CONTRACTOR. SEE PANEL : DRAWINGS FOR ADDITIONAL DETAILS/REQUIREMENTS. 4. ALL WALK-IN COOLER AND FREEZER EVAPORATIVE COILS LOCATED AS SHOWN ON PLANS. 5. ALL 2'-0". CLEARANCE ABOVE NOTED INTERIOR COOLER HEIGHT FOR STRUCTURAL STEEL. 6. CLOSURES/FILLERS FOR ANTHONY WINDOWS TO BE AUTO BRIGHT. PROVIDED AND INSTALLED BY REFRIGERATION CONTRACTOR. 7. SALES FREEZER # 1 TO HAVE POWEREDAIRE AIR DOOR, MODEL: ETD 2-84 FURNISHED BY KYSOR/WARREN AND INSTALLED BY REFRIGERATION CONTRACTOR. 8. SHOP -IN PRODUCE TO HAVE HCR AIR CURTAIN, MODEL: HCR AC -CS. FURNISHED BY PANEL MANUFACTURER AND INSTALLED BY REFRIGERATION CONTRACTOR. 9. SEE COSTCO SPECIFICATION FOR REQUIRED MATERIALS AND METHODOLOGY FOR SANITATION COMPLIANCE IN PREP AREA. DIAMOND PLATE/STAINLESS STEEL LEGEND ALL DIAMOND PLATE FOR POINT OF SALES AND PREP AREAS ARE SUPPLIED BY PANEL MANUFACTURER. INSTALLED BY REFRIGERATION CONTRACTOR. 10 DIAMOND PLATE 3' x LENGTH OF BOX END WALL SEE PANEL DRAWINGS FOR EXACT LOCATION. II 3' TALL DIAMOND PLATE CORNER GUARD SUPPLIED BY PANEL MANUFACTURER AND FIELD INSTALLED BY PANEL REFRIGERATION CONTRACTOR. DIAMOND PLATE 4' H. x LENGTH OF WALL SEE PANEL DRAWINGS FOR EXACT LOCATION. IV STAINLESS STEEL BEHIND SKEWERS (SEE MEAT MANAGER). FIELD VERIFY SIZES. OV STAINLESS STEEL PANEL SKIN ON. EXPOSED PANELS ON ROTISSERIE/MEAT PREP BY PANEL MANUFACTURER. CI 4' TALL DIAMOND PLATE CORNER GUARD SUPPLIED BY PANEL MANUFACTURER AND FIELD INSTALLED BY REFRIGERATION CONTRACTOR. ANTHONY PREP SLIDING/FIXED WINDOWS REFRIGERATION INSTALLATION CONTRACTOR TO COORDINATE THE PREP AREA HEADER SUPPORT POST INSTALLATION WITH THE. G.C. TOP OF HEADER PANEL TO BE 10' - 5 3/4" A.F.F. HEADER OPENING HEIGHT FOR CASES AND WINDOWS IS 6' - 11 3/4". FOR CXI CASES USE: .451" HIGH x 72"AND 45i" HIGH x 96" HEATED PREP SLIDING WINDOWS. PANEL MANUFACTURE TO DETERMINE AND SUPPLY WINDOW LENGTH TO BEST FIT PANEL LAYOUT AND LINE-UP LENGTH PER COSTCO SPECS. R/C AND PANEL MANUFACTURER TO SUPPLY AND INSTALL ALL NECESSARY SUPPORTS, ELECTRICAL COMPONENTS, AND CONNECTIONS TO INSURE CORRECT OPERATION. (REFER TO PANEL MANUFACTURER DRAWINGS FOR EXACT LOCATION). FOR CX2 CASES USE: 354" HIGH x 72"AND 354" HIGH x 96" HEATED PREP SLIDING WINDOWS. PANEL MANUFACTURE TO DETERMINE AND SUPPLY WINDOW LENGTH TO BEST FIT• PANEL LAYOUT AND LINE-UP LENGTH PER COSTCO SPECS. R/C AND PANEL MANUFACTURER TO SUPPLY AND INSTALL ALL NECESSARY SUPPORTS, ELECTRICAL • COMPONENTS, AND CONNECTIONS TO INSURE CORRECT OPERATION. .(REFER TO PANEL MANUFACTURER DRAWINGS FOR EXACT LOCATION). FOR CXI CASES USE: 452" HIGH x 48"AND 452" HIGH x 60" HEATED PREP FIXED WINDOWS. PANEL MANUFACTURE TO DETERMINE AND SUPPLY WINDOW LENGTH TO BEST FIT PANEL LAYOUT AND LINE-UP LENGTH PER COSTCO SPECS. R/C AND PANEL MANUFACTURER TO SUPPLY AND INSTALL ALL NECESSARY SUPPORTS, ELECTRICAL COMPONENTS, AND CONNECTIONS TO INSURE CORRECT OPERATION. (REFER TO PANEL MANUFACTURER DRAWINGS FOR EXACT LOCATION). FOR CX2 CASES USE: 352" HIGH x 48"AND 35" HIGH x 60" HEATED PREP FIXED WINDOWS. PANEL MANUFACTURE TO DETERMINE AND SUPPLY WINDOW LENGTH TO BEST FIT PANEL LAYOUT AND LINE-UP LENGTH PER COSTCO SPECS. R/C AND PANEL MANUFACTURER TO SUPPLY AND INSTALL ALL NECESSARY SUPPORTS, ELECTRICAL COMPONENTS, AND CONNECTIONS TO INSURE CORRECT OPERATION. (REFER TO PANEL MANUFACTURER DRAWINGS FOR EXACT LOCATION). REFRIGERATION INSTALLATION CONTRACTOR TO VERIFY THAT PANEL WIDTH AND WINDOW FRAME WIDTH MATCH. l") (E) BAKERY (E) BAKERY CASE ■ (E) BAKERY COOLER to U ) BAKERYECOOLER (E) (2)GL36-135A BAKERY(E) FREEZER MK24-210KGE W y FRESH AREA PLAN (CONT.) SCALE: 1/8' =1'-0' • 50 n" GC) • • ~� �, �— mil— ��� F mil— ��� —1/� \—f =` L _ .. _• =OIIII 0 (4) BMG520 I I (E) 16'-4" NHMGHP S/D MEAT Uv • lJco co POS (E)io COOLER • co 'tea~ I ----------- I �� \I SHOP-IN(E) MEAT Co g I to v t v w� .-, z 1 I [ - - - - - - - - - 1 I w°> a >--= o COOLER • f 1 I (E) 16.-4" NHMGHP S/D • MEAT A51 ' I L J ,9I • 16'-4" o 8'-4" NHMGHP S (E) S/D DELI (E) 20.-4" D5E M/D DELI - - - I ■ a • — - � (E) (4) MK26-206KGE ,I W w y i• I u) (E) FREEZER #1 10 ,n I v I I MEAT (E)COOLER • I-1 L — N i NI J nJ U II I 0 o-1 s [- I 0 0 �, u7 0 0 ,n v MEAT PREP to co • T) w w POS (E) FREEZER #2 W W 0 O 0 F w w L to I • (E) (3) LFA-190AELO NOTE: RC/PANEL MANUFACTURER TO SUPPLY AND _ rn INSTALL NEW FIXED HEATED WINDOWS. REFER TO 7 • • 1 ANTHONY PREP SLIDING/FIXED WINDOW NOTES 1 R1.0. r--1 AREA OF (E) (2) LFA-190AE I (E) (E) 8'-4" LG3 DUAL TEMP o ' a DELI PREP X I a [ i_ /D DELI ISLAND I/O DELI ISLAND i I/O DELI ISLAND " CX1AG 5/D ME' 1 Ncq S —' I F 1 1 J 0 (E) 56' DX6LN �I J 1 o N111' -I 1 , v "'< (E) ROTISSERIE OVERSTOCK E DELI COOLER •LI• -- I CHICKEN m 0 a (E) 8'-4" J (E) (2) ITG-24-325 • • CX1AG � I S/D MEAT v I L I L POINT OF SALES PLAN L _J SCALE: 1/8" = 1'-0" FRESH AREA PLAN SCALE:118' =1'-0' COSTCO WHOLESALE CO. POATIO\ 999 LAKE DRIVE ISSAQUAH, WA 98027 T: 425.313.8100 www.costco.com KY /annonnasEn #5 CORPORATE RIDGE PKWY. COLUMBUS, GA 31907 Tel: (706)568-1514 Fax: (706)565-1723 HEATCRAFT Worldwide Refrigeration INTEGRITY, COMMITMENT TO STAKEHOLDERS, AND PASSION FOR EXCELLENCE CONTACT INFORMATION SYSTEMS SALES JAY MELANCON C - (706) 536-9477 SYSTEMS ENGINEERING DEPARTMENT CONNER MEADOWS • (800) 866-5596 EXT. 2734 JAMES BIBLE (800) 866-5596 EXT. 2709 • 2-TIER DELI REMODEL ® KYSOR/WARREN: All rights reserved. No part of this document moy be reproduced in any form or by any meons without the expressed written consent of Kysor/Warren. DATE DESCRIPTION EACH CONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO FAMILIARIZE THEMSELVES WITH THIS KNOWLEDGE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY TO PERFORM THE WORK AND ENSURE THE EQUIPMENT OPERATES PROPERLY. ADDITIONAL COMPENSATION SHALL NOT BE •PERMITTED DUE TO CONDITIONS RESULTING FROM FAILURE TO •FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. REFRIGERATION CONTRACTOR TO ADHERE TO ALL EPA GUIDELINES. EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS -BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY -ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. DATE ISSUED: 10/9/2015 DRAWN BY: L.SILVIS REVIEWED FOR CODE COMPLIANCE APPROVED NOV 062015 City of Tukwila BUILDING DIVISION PE REFRIGERATION POINT OF SALES & FRESH AREA PLAN RECEVED Y OF TUKWILA OCT 1 6 2015 RMIT CENTER R1.0 REV. H DATE: ' 10/9/2015 WAREHOUSE IY 006 CITY/STATE/PR/COUNTRY: SOUTHCENTER, WA SCOPE 2 TIER DEU UNEUP REMODEL UNIT LETTER SYSB.T.U.H. NUM REFRIGERATORS REQUIRE) CAPACITY - - REFRIOFRATORIWALK-IN COIL CIRCUITS REF SYS NUM REFRIGERATORIWALK4N COIL ELECTRIC DEFROST TEMPERATURE/DEFROST CONTROL/ MONITOR SUCTION BRANCH NT8 UNE SIZING (EIGHTHS OF AN INCH)REF REF SYS NUM REMARKS . - SYSTEM DESCRIPTION - - - MODEL & MANUFACTURER EWANSION VALVES CASE LENGTH QUANTITY CASE TOTAL LENGTH DISCH AIR .TEMP EVAP TEMP. GPM TOTAL MAX COIL P/D EACH - COMPRESSOR MODEL SYSTEM CAPACITY ,.v w RATn RATIO REF SYS NUM UNE' VOLTAGE FANSICONSTANT HEATERS • (PER UNIT) LIGHTS (PER UNIT) DRAIN HEATERS PER(UNIT) DEFROST VOLTAGE DEFROST 3ph AMPS TOTAL MAIN 3ph INDIVIDUAL DEFROST TEMP. PROBE DEF. PROBE - CONTROL NUMBERS _ av,.,,v,. RRFCCI x0F PRESSURE CONTROL LX1. SOL FIELD INSTALLED 40 EVAP. OFF TIME KOOL GAS ESTIMATED RUN LENGTH LICE SUCT. - RISER MCA MOPD SYSTEM PER FT. PER TOTAL LOAD FAWHTR 8'230R DR/ FAN/HTR 12740Po5DR LIGHTS 6'/2DR18DR LIGHTS 1274DR/5DR MY BRKR TIME TIME 1 SPARE E DX DX - 1 - 1 49YE 7 17 13 1 2 SPARE - E - - DX, DX 2 2 2 3 1/4 POS FREEZER #1 19 x 64 x 18 E SM15558 KGE KRACK E SVE-4 2 E 1 -5 - - 47,200 -14 DX DX 3 480V/3 2.0 - 2.8 3 KOOLGAS - 69VP 07YC E 7 17 13 3 4 1/4 POS FREEZER 172 19 x 64 z 18 E LHG8550 LARKIN E (E) E 1 -15 53,040 -25 DX DX 3DF-0900 34,457 4 480V13 2.8 2.7 (460V11) 4 KOOLGAS - C7 ME-42 S.S. ME-18 E 7 17 13 4 5 1/4 POS FREEZER 47 19 x 64 x 18 E L1G8550 LARKIN E (E) E 1 -15 53,040 " -25 DX DX 4DP-1500 - 52,438 5 460V/3 2.6 2.7 (460V/1) 5 KOOLGAS C7 ME-42 S.S. ME-19 E 7 17 13 5 6 SPARE E - DX DX 4DU-1500 52,438 6 6 07YC 7 17 . 13 6. STA REMOTE PARALLEL COMPRESSOR - 30A4)600 23.234 -. STA AL -28 LOW TEMP. SUCTION GROUP - TOTAL 163,280 -28 162,567- 94.3% - AL 7 12 MEAT COOLER 34 x 40 x 10 E MK28-208 KGE KRACK E +28 33,500 +21 DX DX 7 120V/1 6.4 - 7.0 7 KOOLGAS 20 69VP 42E3 E 5 13 11 7 8 MID DELI E NBDHPM TYLER E 8 1 12 1 I 1 20 +28 1100 22,000 • +25 DX DX 8 120V/1 1.6 2.4 0.95 1.4 8 OFFTIME SPORT9-9 E 5 9 9 8 9 BAKERY COOLER 20 x 20 x 10 E GL38-135A - KRACK E 2 +34 - 24,000 +24 DX DX 9 120V/1 4.8 - 9 OFFIIME - SPORT 7-7 E 4 . 7 7 9 10 BAKERY COOLER 20 x 20 x 10 E HC8A-166AB HUSSMANN E - +34 24,000 +24 DX DX 10 120V/1 6.3 1.53 . - 10 12 69VP 32V3 E 4 9 9 10 11 12 POS 000LER 19 x 64 x 18 E SM28-746A KRACK E SVE4 C . E +34 77,500 +24 DX DX 11 l 480V/3 4.0. 1.63 11 29 69VP 36V 8 E 5 17 13 11 12 MEAT PREP -1,791 SQ FT E LFA-190 LARKIN E SBFVE-C C E 3 +50 70,000 +35 DX DX 3DA3-0750 76,623 12 120V/1 8.4 12 15 89VP 34V8 E 5 11 11 12 " 13 MID DELI E 05E HUSSMANN E - 8 I .12 1 "1 1 20 +31 1355 27,100 - +24 DX DX 3DS-1500 121.2E2 13 120V/1 1.4 2.1 3.6 5.4 13 12 32VS E 5 9 7 13 • 14 SUBCOOLER RACK E +SOUQ 24,798 +35 DX DX 303-1500 121,282 14 - • 14 15 - 12WI81VJ E 14 61 MEAT ISLAND E NHMGHP TYLER E - - E 8 I 12 B 10. 48 +29 425 20,400 +24 DX DX - 61 115V11 1.08 1.56 61 KOOLGAS - 8 PI-2 - X - 190' 5 9 9 81 AH +19 MED. TEMP. SUCTION GROUP - TOTAL 323,298 +19 319,187 101.3% - AH 15 BAKERY FREE7ER-527 SQ FIT( 10 E MK24-210 KGE KRACK E - 2 -5 41,500 -15 DX DX .. 15 120V11 8.4 7.0 15 KOOLGAS 20 69VP 42VS E 5 13 11 15 18 1/4 POS FREEZER #1 19 x 84 x 18 E SM15558 KGE KRACK E 84E4 Z E - 1 -5 47,200 - -14 DX - DX 4DP-1500 73,345 18 4601/13 2.0 2.8 18 KOOLGAS 69VP 07YC E 7 17 13 18 17 1/4 POS FREEZER#1 19 x 64x 18 E SM75556 KGE KRACK E SNITS Z E 1 5 47,200 -14 DX _ DX 4D8-2200 88,934 17 480V/3 20 2.8 17 KOOLGAS 69VP - 07YC E . 7 17 13 17 19 1/4 POS FRFF7FR #1 19 x 644 x 18 E SM15556 KGE KRACK E SVE4 Z E 1 - - -5 47,200 -14 DX DX 405-2200 88,934 19 -120V/1 9.6 12.2 19 KOOLGAS 89VP 07YC E 7 17 13 19 BL -18 LOW TEMP. SUCTION GROUP - TOTAL 153,100 -18 247,214 74.1% BL - 18 12 PRODUCE COOLER 36 x 44 x 20 E EFA-340 TYLER E SBFVE-C C E 3 - +40 94,000 +30 DX DX - 18 120V/1 9.6 18 OFFIIME SPORT 17-17 E 7 17 13 18 20 BAKERY CAKE CASE E - NDFUIP TYLER E - +28 _ - 24,000 +22 DX DX - 20 120Vl1 4.8 20 69VP E 5 11 11 20 21 S/D DELI E NHMGHP . TYLER E 8 1 12 2 . I 2 40 +29 425 17,000 +24 DX DX - 21 120V/1 foe 1.56 - 21 OFFIIME SPORT 9-9 E 5 9 9 21 -" 828H 22 12 MEAT SHOP -IN COOLER 24 x 37 x 20 EM BMG520 BOHN N SBFVE-C C N 2 +28 124,950 . +18 DX DX . 4C2397PL-2NU-01 (E) 123,585 REMOTE 22 120V11 11.2 22 KOOLGAS - 2 (E) (E) SPORT 17-17 (E) (N35) - (N34) E 7 (E) 17 (E) 13 (E) 22 - 23 12 MEAT COOLER 34 x 40 x 10 ' E MK28406 KGE KRACK E +28 33,500 +20 DX DX 'C TO CONTROL AS NECESSAR SATELLITE 23 120V/1 6.4 - 7.0 23 KOOLGAS SPORT 11-11 EPR E 5 11 11 23 24 12 P08 COOLER 19 x 64 x 18 - E SM26-746A KRACK E - SVE4 C E - +34 77,500 +55 DX DX 30T-1500 129,431 24 480V13 4.0 24 20 69VP 38V3 E 5 17 13 24 - 25 MECHANICAL HOUSE 19 x 25 x 10 E SK28-104A KRACK E +75. 25,000 +35 DX DX 30S-1500 122,431 . 25 120V/1 32 25 12 I OW161VJ E 25 26 SUBCOOLER RACK B E +50LI0 37,711 +35 DX DX 3DS-1500 129,431 26 26 15 12VVT61VJ E 28 S1BH SATELLITE COMPRESSOR - - - 3DA-0760 81,955 - - S1BH 60 SHOP -IN DAIRY DOOR N )P5H10-21X21 RUSSELL N EBSVE-B-C N31 1 - - +50 50,000 +36 DX DX 80 BO 2 (E) (E) (N42) SPORT 7-9 (E) 5 (E) TEE) 8 (E) 80 BH +22 MED. TEMP. SUCTION GROUP TOTAL 483,681 +22 470,248 102.9% BH - 29 DUAL -TEMP ISLAND E LG3 -. KNV E 8 1 12 2 I 1 28 -6 425 11,800 -20 DX DX 3DA-0600 23,628 28 -115V/1 2.67 3.79 29 KOOLGAS 3 3 ME-34 S.S. X E 4 7 7 29 30 iM POS FREEZERS 19 x 64 x 18 E LHG8550 - LARKIN E (E) E 1 -15 53,040 -25 DX DX - 4DP-1500 53,327 30 460V/3 2.8 2.7 (480V/1) 30 KOOLGAS C7 ME-34 S.S. ME-19 E 7 17 13 30 31 1!4 POS FREEZER El 18 x 64 x 18 E LHGB-650 ' LARKIN E (E) E •1 -15 53,040 -25 DX DX 403-2200 65,438 • 31 480V/3 2.3 - 2.7 (480V/I) 31 KOOLGAS C7 ME•34 S.S. ME-19 E 7 17 13 31 C1 -28 LOW TEMP. SUCTION GROUP - TOTAL 117,980 -28 - 142,391 82.855 - - - CI 32 DEU PREP -320 SO FT E LFA-190 LARKIN E SBFVE-C C E 2 +50 49,265 +35 DX DX 32 120V/1 2.8 - 32 OFFTIME - - - SPORT 9-9 E 5 9 9 32 33 ROTISSERIE PREP E LFA-087 LARKIN E SBFVE-A C E 2 +50 16,975 +35 DX DX 33 120V/1 2.8 - - . 33 OFFIIME SPORT 9-9 E - 5 9 9 33 34 S!D MEAT UM NHMGHP TYLER BM - E . 8 1 12 2 i 3 82 +27. 425 22,100 +24 DX DX 34 120V/1 1.08 . 1.58 STORE POWER 34 OFFTIME E SPORTII-7 (0 X 200' 8 (E) 9 (q 7 (64 34 N20 N21 N30 N33 N34 N52 132CH 35 12 MEAT SHOP -IN COOLER 24 x 37 x 20 E 8M0520 BOHN N SBFVE•C C N 2 +28 - - • 124,950 +18 DX DX 4C2397PL-2NU-D1 (E) 123,585 REMOTE 35 120V/1 11.2 - - 35 K001 ESE 2 (E) (E) (N42) SPORT 17-17 (E) (434) E 7 (E) 17 (E) 13 (E) 35 36 12 PRODUCE COOLER 38 x 44 x 20 E EFA-340 - TYLER E SBFVE.0 C E 3 +40 94,000 +30 DX DX 'C TO CONTROL AS NECESSAR SATELLJE 38 120V/1 9.6 36 OFFTME SPORT 13.13 E 7 13 13 36 37 DELI ISLAND E D)6LN KM/ E 8 12 4 2 58 +33 1166 65,296 . +28 DX DX - 37 120V/1 0.2 0.4 0.5 0.81 37 OFFIIME 6 (E) SPORT 11-11(E) (E) (E) E 5 (E) 13 (E) 11 (E) 37 38 DEU ISLAND E 0)13LN KNV E 8 12 4 2 58 +33 1166 65,298 +28 DX DX 35 120V/1 0.2 0.4 0.5 0.81 35 OFFTME - 6 (E) SPORT 11-11(E) (E) (E) E 5 (E) 13 (E) 11 (E) 38 39 DEU ISLAND E D)6LN KIW E 8 12 4 2 58 +33 1168 65,296 +28 DX DX 39 120V/1 0.2 0.4 0.5 0.81 39 OFFTIME 6 (E) SPORT 11-11(E) (E) (E) E 5 (E) 13 (E) 11 (E) 39 40 MEAT ISLAND E CXIAG KM E 8 12 2 1 28 +29 376 10,528 +24 DX DX 40 115V/1 0.2 0.4 40 KOOLGAS. - 3 PIE X E 5 9 9 40 41 DEU COOLER 18 x 38 x 20 E IR324-325 RUSSELL E 00FVE-C C E 2 +34 56,000 +24 DX DX 40K-2500 150,230 41 120V/1 14.2 - - 41 OFFTIME- SPORT 13-13 E 5 13 11 41 42 MECHANICAL. HOUSE 19 x 25 x 10 E SK38-164A KRACK E - +75 25,000 +35 DX DX 40H-2500 180,230 42 120V/1 3.2 - 42 - 42 43 SUBCOOLER RACK E +501.4 23,732 +35 DX DX 4DJ-3000 211,551 " 43 43 5 7 7 43 NW 62 62 2 TIER DELI LIT N CX2X0 KW - N 8 I 12 1 2 24 +29 839 20,136 - +24 DX DX 82 115V/1 0.28 0.56 0.5 0.81 STORE POWER 82 OFFTIME 2 N SPORTII.7 (N) X 200' 4 p(N)9 (N) 7 (N) 82 N20 NM N30 N33 N34 MEEST ADD REF CHARGE = 28 LBS 91CH REMOTE PARALLEL COMPRESSOR - 4C1761PL(E) 102,623 - 81C C2 +22 WED. TEMP. SUCTION GROUP TOTAL 638,574 +22 874,634 - 944.7% - - - C2 44 1/4 OVERSTOCK FREEZER 45 x 28 z 18 E BMG520 BOHN E SPE3 Z E 1 -10 . 42,822 -20 DX DX 44 120V/1 11.2 M3 44 KOOLGAS - 1 (E) G'CTP3 CDST-9 (E) X 200 5 (E) 17 (E) 13 (E) 44 45 1!4 OVERSTOCK FREEZER 45 x 28 z 18 E BMG520 BOHN E SPE3 2 E - - 1 -10 42,622 •20 DX DX - 45 120Vl1 11.2 M3 45 - KOOLGAS 1 (E) CDST-9 (E) - X 200 5 (E) 17 (E) 13 (E) 45 48 1/4 OVERSTOCK FREEZER 45 x 28 x 18 E BMG520 BOHN E SPE3 Z E 1 -10 42,622 ,20 DX DX 48 120V11 11.2 M3 48 KOOLGAS 1 (E) COSTA (E) X 200 5 (E) 17 (E) 13 (E) 46 47 1/4 OVERSTOCK FREEZER 45 X 28 x 18 E - BMG520 BOHN E SPE3 Z E - 1 -10 42,622 -,20 DX DX - 47 (20V/1 - 11.2 M3 47 KOOLGAS 1 (E) COSTA (E) X 200 5 (E) 17 (E) 13 (E) 47 - 48 1/5 WALL FREEZER 147 x 5 x 10 E WKG270 • BOHN E EGPE-1-12 Z E 2 - -10 45,080 • -20 DX DX 06ER450 (E) 84,832 20.056 45 120V/1 3.6 M3 48 KOOLGAS 1 (E) C4,C10 COST-9 (E) X 160 5 (E) 17 (E) 13 (E) 48 49 115 WALL FREEZER 147 x 5 z 10 - E WKG270 BOHN E EGPE-1-12 L E 2 -10 45,080 -20 DX DX OBER450 (E) 84,632 20.0% 48 120V/1 3.6 - M3 49 KOOLGAS 1 (E) COST-8 (E) X 160 5 (E) 17 (E) 13 (E) 49 50 1/5 WALL FREEZER 147 x 5 x 10 E WKG270 - BOHN E EGPE-1-12 Z E 2 -10 - 45,080 -20 DX DX 06ER450 (E) 84,832 20.0% 50 120V/1 3.8 M3 50 KOOLGAS 1 (E) COST-9 (E) X - 160 5(E) 17 (E) 13 (E) 50 51 1/5 WALL FREEZER 147x 5 x 10 E WKG270 - BOHN E EGPE-1-12 Z E 2 -10 45,080 -20 DX DX 06ER450 (E) 84,832 20.0% 51 120V/1 3.8 ' M3 51 KOOLGAS 1 (E) GMT-9 (E) X 160 5 (E) 17 (E) 13 (E) 61 52 1/5 WALL FREEZER 147 x 5 z 10 E WKG270 BOHN E EGPE-1-12 Z E 2 -10 45,080 -20 DX DX O6ER450 (E) 84,832 20.0% • 52 120V/1 3.8 - M3 52 KOOLGAS - 1 (E) CDST-9 (E) X 160 5 (E) 17 (E) 13 (E) 52 - 53 SPARE E E - E 8 I 12 8 1 0 48 +29 0 - 0 +24 DX DX - - 53 - 53 (E) (E) (E) 40 DL ,23 LOW TEMP. SUCTION GROUP - TOTAL 395,888 -23 - 423,160 93.6% _ . - - DL - - - 54 12 DEU 8HOP4N COOLER 54 x 28 x 18 E BMG520 BOHN E SPE3 C E - 2 +34 115,698 +24 DX DX - 64 120V/1 11.2 M3 64 KOOLGAS 2 (E) �'C7'P2 COST-17 (E) X 240 7 (E) 17 (E) 13 (E) 54 55 12 DEU SHQP4N COOLER 54 x 28 x 18 E BM0520 BOHN - E SPE3 C E 2 +34 115,698 +24 DX DX 55 120V/1 11.2 M3 55 KOOLGAS - 2 (E) - COST-17 (E) X 240 7 (E) 17 (E) 13 (E) 55 56 SUBCOOLER RACK 01 & D2 E AC70.11 BMY R49 - E SE-30 E +50LI0 126,595 +35 DX DX 08DR541 (E) 150,443 33.3% 58 56 2 (E) CDST-9 (E) RACK 5 (E) 13 (E) 58 SUBCOOLER TO RACK DI & D2 57 SPARE E E - E 8 I 12 6 1 0 48 +29 0 0 +24 DX DX 08DR541 (E) 150,443 33.3% 57 115V/1 - 57 X 300' 5 (N) 8 (Nl) 9 (N) 57 58 DELI SHOP-N DOOR E CUSTOM RUSSELL E SPE-3 C E 1 +50 50,000 • +36 DX DX 06D R541 (E) 150,443 33.3% 58 - 58 1 (E) CDST-9 (E) 240 5 (E) 11 (E) 9 (E) 58 DM +22 MED. TEMP. SUCTION GROUP - - - TOTAL 407,891 +22 451,729 90.4% - DM RACK (D) 232" x 38' x 7811. EST.WT: 8000 L83 MISCELLANEOUS ELECTRICAL DESCRIPTION MODEL VOLTAGE - AMPS WATTS DESCRIPTION - M1 FLUORESCENT LIGHTS 120V/1 2.2 E VAPOR PROOF FLUORESCENT LIGHT FIXTURES PROVIDED AND INSTALLED BY REFRIGERATION ELECTRICAL CONTRACTOR. M2 FREEZER DOOR HEATER - 120V/1 10.0 E - M3 HEAT TAPE 120V/1 16.0 - E - PROVIDED AND INSTALLED BY REFRIGERATION ELECTRICAL CONTRACTOR M4 MULLION LIGHTS POS COOLER ANTHONY CUSTOM 32' 120V/1 41.6 E 64 FIXTURES 82) 0.65 AMPS EACH M5 DR FRAME HEATERS POS COOLER - ' ANTHONY CUSTOM 32' 120V/1 14.2 6 0 2DR FRAME 40 0.59 AMPS I 18 13DR FRAME E 0.89 AMPS I 0 14DR FRAME 40 1.18 AMPS M8 MUWON LIGHTS POS FREEZER #1 ANTHONY CUSTOM 32" - 120V/1 41.6 E 64. FIXTURES 0 0.65 AMPS EACH M7 DR FRAME HEATERS POS FREEZER El ANTHONY CUSTOM 32' - 120V/1 66.4 E 0 2DR FRAME ET 3.87 AMPS I 16 I3DR FRAME 40 5.40 AMPS 1 0 14DR FRAME 10 7.68 AMPS M8 MULLION LIGHTS POS FREEZER 02 ANTHONY CUSTOM 32" 120V/1 41.6 E 64. FIXTURES © 0.65 AMPS EACH •- Mil DR DR FRAME HEATERS POS FREE2ER#2 ANTHONY CUSTOM 32" 120V/1 88.4 E 0 2DR FRAME 40 3.87 AMPS - I 18 I3DR FRAME. ET 5.40 AMPS I 0 14DR FRAME© 7.66 AMPS M10 DUAL TEMP/MEAT ISLAND LIGHTS HOLOPHANE 120V/1 10.5 E 14 FIXTURES © 0.75 AMPS EACH, PER ISLAND 4' FDOURE (STANDARD C08TCO SPEC) SUPPLIED & INSTALLED BY GC. M11 COLD ZONE AIR CURTAIN (POS FREEZER) POWERED ARE E10-2-84 460/3 2.7 / 10 E MCA I MOP PROVIDED BY PANEL MFG. INSTALLED BY REFRGERATON CONTRACTOR M12 SHOPaN AIR DOOR (PRODUCE, DAIRY, DELI) HCR ACES 208V/3 8.6 (E) - MCA / MOP PROVIDED BY PANEL MFG. INSTALLED BY REFRIGERATION CONTRACTOR - M13 CONVENIENCE OUTLET POS FR7/CIR &TOR ISLAND END CAP 120V11 16 EACH E PROVIDED AND INSTALLED BY REFRIGERATION ELECTRICAL CONTRACTOR - M14 HOT CASE (E) E BY OTHERS, TYPICAL, VERIFY PER PROJECT MI5 POS CLR & FRZ BAKERY FRE LIGHTS ERGONOMIC ELS HO-101A 120V/1 1.5 EACH - E 24" x 24" -1.47 AMPS EACH, PROVIOED BY WALK-IN MANUFACTURER, INSTALLED BY REFRIG. ELEC. CONTRACTOR . M16 ANIISWEAT PANELS - SWEATMISER SMIO &SM24 - 120V/1 18.0 E REF. ELE. CONTRACTOR TO PROVIDE POWER TO (2)ASP PANEL AND WIRE ALL GLASS DOOR A/S CIRCUIT'S THROUGH CONTACTS. M17. DEFROST PANEL 120V/1 (E). E MCAIMOPD M18 " HEATED/ SLIDING WINDOWS S ANTHONY 1500 120V/1 11.7 N (3) SECTION 403.E AMPS EACH M19 THERMO-SIMPLE DISPLAY UNE INNOVATIONS 5V-DC5V-OC (E) E POWERED VIA CAT-5 CABLE RUN TO TRANSFORMER (WIRED IN SERIES) M20 THERMOSIMPLE PROBE INNOVATIONS (E) E TO BE MOUNTED 8' AFF N121 THERMOSMPLE TRANSFORMER INNOVATIONS 120V/1 (E) E TO BE MOUNTED ON TOP OF POS COOLER & FREEZERS, AND PRODUCE COOLER - 5/122 HEATED PRESSURE REUEF PORT KASON 120V/1 (E) E PROVIDED BY PANEL MANUFACTURER M23 MT INPUT & ALARM PANEL (BELL&STROBE) - MT INPUT W/ ALARM 120V/1 . 18.0 E - REFRIGERATION ELECTRICAL CONTRACTOR TO PROVIDE POWER TO MT INPUT ALARM PANEL, INCL KVM TERMINAL CURET. M124 POS FREEZER FAN PANEL POS FREEZER FAN PANEL - N/A REF. ELE. CONTACTOR TO PROVIDE POWER TO POS FREEZER FAN PANEL. ALSO RUN WIRING TO COILS & SOL AS NECESSARY. 1E25 MEZZANINE FAN PANEL MEZZANINE FAN PANEL WA REF. ELE. CONTRACTOR TO PROVIDE POWER TO FAN PANEL ALSO RUN WIRING TO COILS & SOL AS NECESSARY. M26 EQUIPMENT POWER EQUIPMENT POWER SEE NOTE- REF. ELE. CONTRACTOR TO PROVIDE POWER TO ALL EQUPMENT AS CALLED OUT BY THIS NOTE AS NECESSARY. SEE LEGEND AND/OR EQUIPMENT FOR VOLTAGE&AMPERE. M27 MACHINE ROOM EXHAUST VENT-A)OA 120V71 - 1.2 - E M29 PUMP STATION HA - M30 CONDENSER/POWER-CONDENSER CONTROL INSTAWNG CONTRACTOR TO PROVIDE ANY AND ALL MATERIALS FOR PROPER INSTALLATION & OPERATION (N) ' - ALSO SEE REMOTE CONDENSER SECTION ON THIS LEGEND (A) A 18 GA. TWISTED PAIR NONE SHELDED CABLE (NETWORK) (TO RACKS) - (B) A 22 GA 3 CONDUCTORS CABLE FROM THE DROP LEG PRESS. TRANSDUCER TO INPUT U3 (AT CONDENSERS) (C) A 22 GA 2 CONDUCTORS CABLE FROM THE DROP LEG TEMPERATURE SENSOR TO INPUT U4 (AT CONDENSERS) (D) A10K OHM 5977DF TYPE 2 SENSORS. SHOULD BE UNDER THE FIRST FAN ON THE HEADER SIDE ON INPUT U5 (OUTSIDE AIR) M31 E."'."" "� ""'�'�`"" """" r ANTHONY CUSTOM 32" 120V/1 17.6 E 27 FIXTURES © 0.65 AMPS EACH -- M32 (Gi ., o "'""""'""'" "'-`i"`a ""' rnAILIAtt ANTHONY CUSTOM 32' 120V/7 38.3 E 1 2DR FRAME (1( 3.67 AMPS I 8 I3DR FRAME 41 5.40 AMPS I 0 14DR FRAME 40 7.66 AMPS M33 MUWON LIGHTS WALL FREEZER (NEW) ANTHONY CUSTOM 32" 120V/1. 41.6 - E 64 FIGURES 00 0.55 AMPS EACH M34 MULLION LIGHTS WALL FREEZER (NEW) ANTHONY CUSTOM 32" 120V/1 66.4 E 0 2DR FRAME 40 3.87 AMPS 1 18 13DR FRAME 40 5.40 AMPS I 0 14DR FRAME TE 7.66 AMPS MISCEUANEOUS ELECTRICAL C1 REFRIGERATION THERMOSTAT TS 120V/1 RUN TO CONDENSING UNE CONTROL PANEL. C2 TEMPERATURE SENSOR & SOLENOID S - 120V/1 RUN 4 SENSOR WIRES TO RACK SYSTEM CONTROL PANEL (2) FOR SOLENOID (2) FOR COMPRESSOR CONTRACTOR - C3 DEFROST SOLENOID D8 120V/1 RUN TO SYSTEM CONTROL PANEL C4 DEFROST TERMINATION SENSOR - DT - FAN DELAY WTTi SEPARATE DEFROST TERMINATION KLDDN .,,.a "•, c,E,,, ,cV V,, ,,.,,v...,,,,, �VM1,v,•, LE,,,,,, ,E,,,,,,,,,,,,,,,,,'v,uuwavro r"„Gn..a vvr:,w r,,,�u aTLanC AIfMREmu C5 DOOR SWITCH SOLENOID SENTROL#115-17Y-06K 24V WIRE IN SERIES WITH FAN POWER CIRCUIT.- MAGNETIC DOOR SWITCH TO BE FIELD SUPPUED. C8 EMERGENCY REFRIGERANT STOP - 120V/1 - WIRE TO MT INPUT BOARD. C7 FAN STOP/LIQUID LINE SOLENOID 120V/1 . - POWER FOR SOLENOID FROM COIL WIRE THROUGH AUXILIARY CONTACTS ON KILL SWTCH CONNECTED IN FIELD. C8 DUAL TEMP & DEF. TERM. SOL CONTROL 120V/1 (2) I/14 FROM RACK TO EACH DUAL TEMP FOE. FOR ES2, (2) E14 PER LS. FOR DEF. TERM SOL PWR IN SERIES W/ CASE KIJXONS. C9 TEMPERATURE SENSOR & LIQ. SOLENOID WIRE TEMP. PROBE TO THE MT #0 BOARD FOR TEMP CONTROL WITH OUTPUT TO CLOSE LL SOLENOID VALUE. C10 DUAL TEMP KEY SWITCH - RACK MOUNTED & CURED DPDT KEY SWITCH MT TO SWITCH TEMP. ALARM SET POETS FOR MED & LOW TEMP. BASED ON DT. TEMPERATURE SENSORS S REFRIGERATOR TEMPERATURE SENSOR WIRE TO CONTROLLER INPUT PANEL, SEE DETAIL SHEET FOR LOCATION OF PANELS. - P1 PROOF INPUT - AIR CURTAIN POS FREEZER WIRE TO CONTROLLER INPUT PANEL, SEE DETAIL SHEET FOR LOCATION OF PANELS. P2 PROOF INPUT- AIR DOOR - SHOP -INS (DP) - WIRE TO CONTROLLER INPUT PANEL, SEE DETAIL SHEET FOR LOCATION OF PANELS. P3 PROOF INPUT SLIDER 0R SWING CLOSED MS WIRE TO CONTROLLER INPUT PANEL, SEE DETAIL SHEET FOR LOCATION OF PANELS. COMPRESSOR SUMMARY AND ACCESSORIES UNIT MODIFICATIONS AND ACCESSORIES UNE LETTER A B C D RACK ASSEMBLY E E E (E) RACK SPRINGS - E E E YES COMPRESSOR E E E CARLYLE VERT. RECENER SIZE E E E 18x87 RECEIVER CAP. 40 8016 FULL. E E E RACK CONTROLS !ELECTRICAL MAIN CONTROLLER EPC EPC MCC - MT OUTPUT BOARD E E E (E) MT MONTORING PACKAGE . E E E (E) TRANSFORMER E E E (E) SUCTION TRANSDUCER E E E (E) DISCHARGE TRANSDUCER E E E (E) DROP LEG TRANSDUCER - - E E E (E) SUCTION TEMP. E E E (E) DISCHARGE TEMP E E E (E) DROP LEG TEMP E E E (E) LEAK DETECTION SYSTEM E E E (E) LEAK DETECTION PROBES E - E E (E) SINGLE PHASE PROTECT. E E E (E) DUAL PRESSURE CONTROL WA WA WA N/A LOW PRESSURE CONTROL E E E (E) HIGH PRESSURE CONTROL E E E (E) OIL FAILURE CONTROL E E E (E) BASIC ALARM E E E (E) REC. REF. LOSS ALARM E E E (E) HIGH SUCTION ALARM E E E (E) ALARM BELL E SATELUTES/BOOSTER REMOTE SATEWTE/BOOSTER N (1) N (1) RACK MOUNTED SATIBOOSTER N (1) DI8CH CHECK VALVE Y Y SAT OIL MODIFIER ONE/IWO-TER RACK Y Y EQUIPMENT LEGEND N - NEW E EN3TING R REFURBISHED FJM E83TNG MODIFIED E/R DIETING RELOCATED F FUTURE UNE SIZE LEGEND 3 1/8" x 3 = 3/8" 4 1/8'x4=12" 5 118' x 5. 5/8" 7 1/8"x7. 718' 9 - 1/8" x 9.1 1/8" 11 1/6"x 11 = 1 3/8" • 13 1/8"x13=15/8' 17 1/Ex17.21/8" 21 - 1/8"x21.25/8" RACK PIP1N0 ACCESSORIES MT LE A 8 C D RISC RACK PARTS OIL SEPARATOR (HELICAL) S5203 85203 85023 (E) OIL RESERVOIR - OR83A (E) HEAT RECLAIM LOCKOUT HOT WATER TANK/TEMP CONTROL SPLIT CONDENSER COED BALL VALVES TO/FROM (E) HEAT RECLAIM BALL VALVE (E) LIQUID DRIER ASSEMBLY (E) MAN LIQUID LINE SOLENOID (E) WINTER CONLROL/PRESSURE REG. (E) - SUBCOOUNO ASSEMBLY (E) SPLIT SUCTION MODIFICATION (E) SUCTION/LIMED MANE INSULATION (E) SUCTION ACCUMULATOR ISUCTION (E) FILTERS (E) WARM FLUID HE AND CONTROL REMOTE DEFROST PANELS 460V/DEFROST PANEL MAIN BREAKER SUB -BREAKER CONTACTORS FAN BREAKER/CONTACTORS REMOTE CONDENSERS UNIT LETTER RACK A RACK B RACK C RACK D MFG. BOHN (E) MODEL HLCV-V8410M HLCV-V8412M HLCV-1412M DNH012-A106 FANS 12 FPI 10 CIR.AVNL /USED CIR. (00000 PER CIR) COND. CAPACITY 401 DEGREE ID 65,700 65,700 98,700 103,479 ALTO UDE CORRECTION FACTOR 1 _ 1 1 1 ADJUSTED COND. CAPACITY 65,700 65,700 98,700 103,479 REJECTION MBH OF RACK 40 DESIGN 679,221 1,137,700 1,571,533 1,075,889 TEMPERATURE DIFFERENCE AID 10.34 17.32 15.92 - 10.40 REJ. MBH OF RACK © 10%SAFETY 747,143 1,251,470 1,728,688 1,183,478 AM W/10% SAFETY 11.37 19.05 17.51 11.44 LENGTH 166' 166' 328' 324" WIDTH 96" 96' 86' 88" HEIGHT 65" 55' 55" 49' WEIGHT 2800 LBS 2880 LBS 5800 LBS 4230 LBS DISCHARGE UNE (2) 15/8 (2) 2-1/8 2-1/8 (2) 2-1/8 LIQUID UNE (2) 15/8 (2) 1-5/8 - 2-1/8 (2) 2-1/8 VOLTAGE - MCA I MOP 42.9 / 50 CONDENSER CONTROLS - - - RPMS 1140 (E) 950 77 (E) 1140 (E) . 1140 (E) NOTES UNIT LETTER $ :L E. z O - • STA AL AL. AL - s, E. z 0 - I- d tl1 - - - AH AH AH SUCTION BL (-18)• BL BL BL SPLIT SUCTION SIBH / BH (+22) BH BH BH 31BH • 828H 5 z 0 01,571,533 C1 C1 CI SPLIT SUCTION SIC I C2 (+22) C2 - C2 . C2 S1 CH 92CH SUCTION DL (-23) DL SPLIT SUCTION DLI (+22) - DM DM UNLOADER 1 _ 1 1 EA. 2 1 EA. COMPRESSOR QIAMTTY 1 1 - - 1 1 1 1 1 1 1 - 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5 1 2 COMPRESSOR MODEL 3DA-0600 3DF-0900 4014-1500 4014-1500 3DA3-0750 305-1500 305-1500 4DP1500 4DS2200 41)92200 30T-1500 303•1500 30E1500 304-0750 402397141(E) 304-0600 4014-1500 405-2200 4DK-2500 401+2500 406-3000 4C1781PL(ET 402397141(E) 06ER450(E) 0606541(E) 0606541(E) COMPRESSOR ASSEMBLY - REMOTE RETORFO REMOTE - - COMPRESSOR MANUFACTURER BITZER _ BT2ER BITZER . CARLYLE CARLYLE CARLYLE COMPRESSOR FAN - - YES - - NO YES YES NO NO OIL LEVEL REGULATOR 5-9090DE 8-9090DE 5-8090DE 5-9090DE 5-9090DE 3&090DE DISCHARGE MUFFLER - COMPRESSOR CONTRACTOR - 40 30 40 40 30 30 HORSEPOWER PER (EACH) 1.84 2.43 3.70 3.70 8.39 10.11 10.11 5.18 6.14 8.14 10.79 10.78 . 10.79 6.83 10.3 1.64 3.70 4.54 15.02 - 15.02 17.83 8.55 10.3 4.97 12.54 12.54 REFRIGERANT R-22 • R-22 R-22 R-22 R-22 R-22 R-22 R-22 - R-22 R-22 R-22 R-22 R-22 R-22 R-22 R•22 R-72 R-22 R-22 R-22 R-22 R,72 R-22 R-507 R507 R-507 SUCTION TEMPERATURE -28 -28 -28 -28 +19 +19 +19 -18 - -18 -18 . +22 +22 +22 +22 16 -28 -28 -28 +22 +22 +22 +22 16 -23 *22 +22 CONDENSING TEMPERATURE 105 110 110 . 110 110 110 - 110 110 110 110 110 110 110 110 110 110 110 - 110 - 110 110 110 110 110 110 110 110 CAPACNY MBH W/O SUBCOOUNG (EACH) 19,890 29,201 44,439 44,439 78,623 - 121,282 121,282 82,157 73,873 73873 129,431 129,431 129,431 81,955 . 123,585 19,690 44,439 54,530 180,230 180,230 211,551 102,623 123,585 69,600 150,443 150,443 WATTS MBH (EACH) 4,490 6,540 10,410 10,410 7,860 12,720 12,720 12,030 14,140 14140 12,990 12,990 12,990 8,010 13,359 4,490 10,410 12,430 17,690 17,690 21,410 10,135 13,359 12,528 18,888 16,888 REJECTION MBH (EACH) 35,028 51,515 79,962 79,982 103,342 164,706 184,708 103,212 121,919 121919 173,769 173,789 173,789 109,293 180,050 35,028 79,962 - 96,943 240,598 240,598 684,813 133,745 160,050 93,796 202,303 202,303 REJECTION MBH (TOTAL) 678,221 1,137,700 1,075,889 SUBCOOUNG CREDIT % 1.18% 1.18% 1.18% - 1.18% - 1.18% 1.18% 1.15% 1.20% 1.20% _ 1.20% _ - 1.42% COMPRESSOR RLA (EACH) 15.0 18.0 24.0 24.0 18.0 28.0 28.0 24.0 30.0 30.0 28.0 28.0 28.0 20.0 28.8 - 15.0 24.0 30.0 40.8 40.6 45.0 21.2 28.8 33.9 25.8 25.8 UNIT RLA 149.0 - 1820 218.4 248.3 UNIT MCA - - - 155.5 - 189.5 38.0 227.7 38.0 254.8 UMT MOPD 175 (E) 200 (E) 80 250 (E) 60 300 (E) 120V CONTROL CIRCUIT MCA /MOPD - - 25 - BOTTOM. RACK BOTTOM REMOTE MOUNTED REMOTE - . - SATELLITE SATELLITE - - NOTES N5 N5 N5 N5 N5 N5 N5 N6 N5 - N6 N5 N5 N8 NS N5 N5 - N5 N5 N5 NS N5 N5 N5 N6 NB N6 REVISIONS REV DATE BY: DESCRIPTION C 1017/2008 MRM DELI- ROTISSERIE EXPANSION • D 11/8/2008 MRM REVISE DEU PREP COILS E _ 8/182011 DL NEW SHOP -IN COOLER OVERSTOCK FREEZER, WALL FREEZER, REPLACE DELI ISLANDS F 10/32011 JM REVISED SHOP -IN DARE TO SHOP -IN MEAT. ADD SATELLITES TO RACK B & C. USE OUSTING CONDENSERS. G 7/122013 FC NEW DUAL TEMP AND MEAT ISLAND REMODEL H 1019/2015 CM 2 TIER DELI LINEUP REMODEL REFRIGERATION SYSTEM NOTES 1 `TOTAL REFRIGERATION SYSTEMS COMBINED WILL CONTAIN LESS THAN 4,000 LBS OF R507 (GROUP A-1 CLASSIFIED BY IMC 2006) .. 2 TOTAL WAREHOUSE VOLUME LS 3,149,300 CUBIC FEET OD DISBURSABLE AREA. IMC 2008 TABLE 1103.1 ALLOWS 17 LBS. PER CU.FT., OR 53538 LBS 3 UMC 2008 HORSE POWER RATINGS: AL • 11.47 AH • 28.81 BL • 17.48 BH • 49.50 C1 • 9.88 C2. 68.52 01 • 24.85 D2. 37.62 4 BASED ON APPUCABLE REQUIREMENTS IN CHAPTER 11 OF THE IMC 2006, THE SYSTEMS ARE BELOW THE REFRIGERATE QUANTITY AND/OR 100 HP REQUIREMENTS. THEREFORE A REFRIGERATION MACHNERY ROOM IS NOT REQUIRED. 5 PER THE UMC 2000 TABLE 11-11, ITALLOWS 9.4 LBS PER 1000 CU. FT. OR 29603 LBS. - - - GENERAL NOTES NI NEW RACK/RACKS ANDIOR CONDENSERS SUPPLIED BY KYSOR/WARREN. N2 BOOSTER AND/OR SATELLITE UNIT TO BE SUPPLIED BY KYSOR/WARREN - BREAKER & CONTACTOR WILL BE PRE -INSTALLED IN UNIT CONTROL PANEL. NS CONTRACTOR TO VERIFY PROPER LOCATION FOR BOOSTER UNE IN DUSTING COMPRESSOR ROOM AND INSTALL AS CLOSE TO RACK AS POSSIBLE FOR PROPER CLEARANCE. - N4 INSTALLING CONTRACTOR TO PIPE NEW BOOSTER TO MMN SUCTCN GROUP OR PIPE SATEWTE TO RESPECTIVE CIRCUITAND PROVIDE ANY NECESSARY MATERIAL MICHAS BALL & HAND VALVE, ETC. SEE DETAL SHEET FOR DETAILS. - N5 NSTALUNG CONTRACTOR TO MODIFY SATELLITE COMPRESSOR PIPING TO CONVERT TO BOOSTER FOR MAN SUCTION GROUP COMPRE88OFL - .. 18 NSTALUNG CONTRACTOR TO RUN CONTROL WIRING FROM BOOSTER/SATELLTIE TO RACK. VERIFY RO, D1/A1 POINTS, SUPPLY NECESSARY BOARDS IF NEEDED. N7 NSTALUNG CONTRACTOR TO REMOVE ENSTNG COMPRESSOR & INSTALL NEW COMPRESSOR. PROVIDE ALL NECESSARY MATERIAL TO COMPLETE INSTALLATION. N8 NSTALUNG CONTRACTOR TO INSTALL NEW BREAKER & CONTACTOR FOR NEW COMPRESSOR. SUPPLIED BY KYSORNYARREN. N9 COMPRESSOR BODY AND ACCESSORES PROVIDED BY & INSTALLED BY REFRIGERATION CONTRACTOR N10 - NSTALUNG CONTRACTOR TO PROVIDE AND INSTALL; 8(12FR COMPRESSOR ACCESSORIES, MOUNTING HARDWARE, OIL FLOATS, LIQUID INJECTION, ETC. N11 LIQUID INJECTION UNES REQUIRE A SOLENOID WIRED TO COMPRESSOR AUD0LARY CONTACTS (ONLY ACTIVE WHEN COMPRESSOR LS RUNNING). N12 NSTALUNG RIC TO FOLLOW ALL BITZER INSTALLATION GUIDE UNE$, N13 NSTALUNG RIC TO VERIFY E)BSTN G MODEL NUMBERS, SPACING AVAILABLE & QUANTITY OF MISTING AND NEW COMPRESSORS . N14 NSTALUNG RIC TO INSTALL NEW OIL SYSTEM ON RACK. OIL SEPARATOR AND RESERVOIR SUPPLED BY KEY. ALL OTHER MATERIAL SUPPLIED BY RIC. N15 WC TO VERIFY THAT E)4SENG OIL SEPARATOR & RESERVOIR WILL MEET NEW RACK LOAD. IF EXSTING EQUIPMENT DOES NOT MEET RACK LOAD, THE RIC IS TO PROVIDE A MODEL 8d000SEPARATOR AND/OR A RESERVOIR (MIN. 3 GAL CAPACITY) AS NECESSARY. N16 NSTALUNG CONTRACTOR TO REMOVE FASTING EQIPMENT AS NECESSARY. - NIT RESPECTIVE FIXTURE/CIRCUIT TO BE RELOCATED AND/OR RE -PIPED BY INSTAWNG CONTRACTOR TO THE RESPECTIVE SYSTEM SHOWN ON THE REFRIGERATION SCHEDULE. - - N20 EASING CIRCUITO BE FIELD VERIFIED BY INSTAWNG CONTRACTOR TO CONFIRM ANY DISCREPANCIES ON THE REFRIGERATION SCHEDULE. NTT N8TALUNG CONTRACTOR TO VERFY E)03T1G SUCTION AND LIQUID UNE SEES TO CASES, COOLERS, FREEZER, AND ANY OTHER EQUIPMENT LISTED ON THE REFRGERATON SCHEDULE AND MODIFY AND/OR CHANGE AS NECESSARY. - N22 NSTALUNG CONTRACTOR TO RUN NEW UNE SET TO RESPECTIVE FIXTURE. N23 DEMO OF CIRCUIT, CASE, COOLER, AIND'OR FREEZER CUT LOOSE IN THE OVER OR AT CONNECTION IN PIT. CAP OFF WITH CAPS (DO NOT PINCH UNES). TURN OFF BALLVALVES AT RACK. TAG CONTROL PANEL SPARE AND TAG BALL VALVES A3 SPARES. - N124 NSTAWNG CONTRACTOR TO VERFY POSTING DISCHARGE AND DRAIN UNE SIZES TO CONDENSER AND MODIFY ANDIOR CHANGE TO MATCH INFO SHOWN ON REFRIGERATION LEGEND ONLY IF NECESSARY. - - 125 NSTALUNG CONTRACTOR TO SETA/H, RUN DUCT WORK, SUPPLY & INSTALL GRILLS, PROVIDE ANY & ALL MATERIAL TO INSURE PROPER OPERATION. O.C. TO SUPPLY PLATFORM. N30 EPR, LL SOLENOID, AND/OR SUCT. STOP, HEAT RECLAIM VALVE & OTHER EQUIPMENT/MATERIALS SHOWN TO BE SUPPUED AND _ INSTALLED BY REFRIGERATION CONTRACTOR N31 EXPANSION VALVES AND/OR DISTRIBUTOR/ORIFICE/NOZZLE PROVIDED AND INSTALLED BY REFRIGERATION CONTRACTOR - N32 INSTALLING CONTRACTOR TO PROVIDE EPR OR CONTROL VALVE AS NECESSARY. N33 NSTALUNG CONTRACTOR TO SUPPLY NECESSARY VALVINO TO PIPE CIRCUIT OR NEW STUB TO RESPECTIVE RACKS. N34 NSTALUNG CONTRACTOR TO SUPPLY NECESSARY DEFROST COMPONENTS AND INSTALL AS NECESSARY. N35 LL SOLENOIDAND BYPASS CHECK VALVES TO BE SUPPLIED BY AND MOUNTED BY R/C. COMPLETE WIRING OF SOL., FANS, - AND DEFROST THERM. TEMP SENSORS TO FAN PANEL FOR PROPER OPERATION BY REFRIGERATION CONTRAC70R N35 R/C R/C TO PROVIDE KEY SWITCHES et RACK IN THE MOTOR ROOM FOR DUAL TEMP / MED TEMP OPERATIONS. WIRE KEY SWITCHES AS NECCESARY. N41 INSTALLING CONTRACTOR TO MODIFY, CHANGE, OR ADD CONDENSER PLATFORM AND/OR SUPPORT STEEL AS NEEDED PER STRUCTURAL ENGINEER ON RECORD. 1442. NSTALUNG CONTRACTOR TO SUPPLY& INSTALL ANY EMS AND OTHER CONTROL EQUIPMENT TO INSURE PROPER OPERATION OF EQUPMENTSUPPUED BY KEE N50 EVAPORATOR FANS AND DRAIN PANS ARE NON -CONCURRENT LOADS. N51 ELECTRICAL CONTRACTOR TO VERIFY ELECTRICAL SERVICE IS AMPLE TO SUPPLY POWER TO UNIT AND/OR RACK AND CONDENSERS - MODIFY AS NEEDED. N52 ELECTRICAL CONTRACTOR TO VERIFY ELECTRICAL SERVICE IS AMPLE TO SUPPLY POWER TO CASES, COLS, LIGHTS, OUTLETS, ETC. - MODIFY AS NEEDED. N53 ELECTRICAL CONTRACTOR TO SUPPLY NEW POWER SOURCE NOT FROM RACK POWER ELECTRICAL NOTES ELECTRICAL CONTRACTOR SHALL: . 1 USE MATERIALS AND METHODS THAT CONFORM TO ALL APPUCABLE CODES AND ORDINANCES. 2 USE NO ALUMIMJM WIRE TO CONNECT ANY REFRIGERATION MANUFACTURED EQUIPMENT. 3 VERIFY LOCATIONS OF ELECTRICAL STUB -UPS FOR REFRIGERATED CASES WITH REFRIGERATION CONTRACTOR PRIOR TO INSTALLATION. 4 SURFACE MOUNT ALL CONDUIT FOR MEAT/DELI & PRODUCE REFRIGERATED WALK-IN BOXES ON THE EXTERIOR OF THE WALK-IN BODES. SEAL ALL PERFORATIONS WITH PERMAGUM OR EQUAL. - 5 CONNECT ALL POINT OF SALES (PIS) BLOWER COIL FAN MOTORS TO ACCESSIBLE DISCONNECT. DISCONNECT MUST DE-ENERGEE REFRIGERANT SOLENOID VALVE TO STOP FLOW. AU. NECESSARY RELAYS FURNISHED BY ELECTRCAL CONTRACTOR - B FURNISH AND INSTALL CONDUIT, WIRE, OUTLETS, ETC. FOR REFRIGERATION RETIRES AND CONNECT COMPLETE AND READY TO OPERATE AS DIRECTED BY THE REFRIGERATION CONTRACTOR ELECTRICAL CONTRACTOR SHALL ALSO FURNISH AND INSTALL ANY NECESSARY DISCONNECTS AND CONTACTORS. 7 REVIEW THE ELECTRICAL PLANS AND DIAGRAMS PRIORTO CONSTRUCTION. CONTACT REFRIGERATION MANUFACTURER IF CLARIFICATION IS NEEDED.. UPON COMPLETION OF WRING, THIS CONTRACTOR SHALL PERFORM A SATISFACTORY OPERATIONAL CONTROL SEQUENCE, CHECK WITH 1-E R/C. S MOUNT AND/OR CONNECT ALL THERMOSTATS, SOLENOIDS, AND OTHER ELECTRICAL CONTROLS FURNISHED BY THE REFRIGERATION CONTRACTOR . CONNECT ALL MOTORS, CONTROLS, AND OTHER COMPONENTS FURNISHED BY THIS CONTRACTOR - - 9 FURNISH AND INSTALL CONDUIT, WIRE, OUTLETS, ETC., FOR ALL LIGHTS, HEATERS, WALK-IN BOZES, AND/OR REACH -IN DOOR ASSEMBUES AND ALL OTER FIXTURES AS REQUIRED. THESE FIXTURES ARE PROVIDED BY REFRIGERATION CONTRACTOR AND INSTALLED BY THE ELECTRICAL CONTRACTOR 10 INSTALL ALARM BELL, FURNISHED BY REFRIGERATION CONTRACTOR AND INSTALLED BY THE ELECTRICAL CONTRACTORS. 11 FURNISH AND INSTALL ALL FUSED DISCONNECTS AND/OR MOTOR STARTERS NOT SPECIFICALLY SUPPLIED BY REFRIGERATION MANUFACTURER 12 CONNECT ALL COOLER AND FREEZER DOOR LIGHTS TO ENERGY MANAGEMENT SYSTEM PROVIDED BY OWNER 13 RUN CONDUIT INSIDE THE OVERHEAD TRUSS WORK. 14 PROVIDE AS -BOAT PANEL SCHEDULES FOR ALL ELECTRICAL LOADS SHOWN ON REFRIGERATION MANUFACTURERS SCHEDULES. DESIGN CONDITIONS FOR COSTCO 0008 SOUDJCENTER, WA - INSIDE DESIGN TEMP: 75F DRY BULB 65% RELATIVE HUMIDITY ENGINEER: FC OUTSIDE DESIGN TEMP: 95F DRY BULB 68F WET BULB .. CONDENSER TYPE: AIR COOLED R-22IR-404A SUPER PLUS/PROTO,AIRE VOLTAGE / HERTZ/ PHASE: 460 / 60/ 3 COSTCO WHOLESALE COPOATIO\ 999 LAKE DRIVE ISSAQUAH, WA 98027 T: 425.313.8100 www.costco.com KY BIB E #5 CORPORATE RIDGE PKWY. COLUMBUS, GA 31907 Tel (706)568-1514 Fax: (706)565-1723 INTEGRITY, COMMITMENT TO STAKEHOLDERS, AND PASSION FOR EXCELLENCE CONTACT INFORMATION SYSTEMS SALES JAY MELANCON C - (706) 536-9477 SYSTEMS ENGINEERING DEPARTMENT CONNER MEADOWS (800) 866-5596 EXT. 2734 JAMES BIBLE - (800) 866-5596 EXT. 2709 2-TIER DELI REMODEL 0 KYSOR/WARREN: All rights reserved, No part of this document may be reproduced in any form or by any means without the expressed written consent of Kysor/Warren. DATE DESCRIPTION DATE ISSUED: 10/9/2015 DRAWN BY: L.SILVIS REFRIGERATION SCHEDULES - REVIEWED FOR ODE COMPLIANCE APPROVED NOV 06 2015 City of Tukwila UILDING DIVISION T ECElV Erb CiTY OF TUKWILA OCT 1 6 2015 PERMIT CENTER EACH CONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO FAMILIARIZE THEMSELVES WITH THIS KNOWLEDGE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY TO PERFORM THE WORK AND ENSURE THE EQUIPMENT OPERATES PROPERLY. ADDITIONAL COMPENSATION SHALL NOT BE PERMITTED DUE TO CONDITIONS RESULTING FROM FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. REFRIGERATION CONTRACTOR TO ADHERE TO ALL EPA GUIDELINES. EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDI CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMO EXISTING CONDITIONS. Y N! RFL�, M.-_ XACT -B IL ° MITT! R3