Loading...
HomeMy WebLinkAboutPermit M15-0139 - ANDOVER PARK EAST - BUILDING 17 - ROOFTOOP AIR HANDLER UNIT REPLACEMENTSANDOVER PARK EAST BLDG 17 701 INDUSTRY DR EXPIRED 05/18/16 M15-0139 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2523049008 701 INDUSTRY DR MECHANICAL PERMIT Project Name: ANDOVER PARK EAST- BLDG 17 Permit Number: Issue Date: Permit Expires On: M15-0139 11/20/2015 5/18/2016 Owner: Name: Address: NCWP ANDOVER EXECUTIVE PARK 810 NW MARSHALLS ST #300 , PORTLAND, WA, 97209 Contact Person: Name: JAE Y00 Address: 7202 NE 135 ST, KENMORE, WA, 98028 Contractor: Name: G B SYSTEMS INC Address: 7202 NE 175TH ST, KENMORE, WA, 98028 License No: GBSYSI*088BS Lender: Name: Address: Phone: (425) 482-0584 Phone: (425) 482-0584 Expiration Date: 1/10/2017 DESCRIPTION OF WORK: REMOVE (2) EXISTING ROOFTOP AIR HANDLER UNITS, REPLACE THEM WITH (2) NEW UNITS. Valuation of Work: $15,350.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $402.68 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: Date: (1/�/7S I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree toe conditions attached to this permit. Signature: Print Name: Date: /(./20/ z6lj— This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 1800 0705 0701 MECH EQUIP EFF MECHANICAL FINAL REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit issued by the City of Tukwila the job site at the time of inspection. CITY OF TUKWI... . Community Development Department Permit Center 6300 Southcenter Blvd.. Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.2ov Mechanical Permit No. Project No. Nits--01V Date Application Accepted: Date Application Expires: [O-)t--(S T (For office use onhy MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 1 (NtaUS1R ( D2_ Tenant Name: ANDaJ _ 4 PROPERTY OWNER Name: 0.4P hrlt'a tIER. ti(GZv"fl I2VK t 1.-La Address:505 UNtONi Ave STr IZo City: OLrir IPr State: W A Zip:850( CONTACT PERSON — person receiving all project communication Name: -THE YJo Address:7201 sic (7-9r'- ST State: W Zip:,i3,024 City:Y—e-1•114101?-- Phone: 425 -,02 -0$,4 Fax: 425, - L(62 _o5- a Email: JAMtnI ye 613S —H VA-C • C,OWI King, Co Assessor's Tax No.: 2-92.30'-1 - of oo8 --'trite Number: 1 7 Floor: New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: a 41,S-re,._1U4S Address: .2®2 we- (.5 '''" S'7 City: -IFN14011',E State: wx Zip:180 as Phone: 5 — 48L-OSseax:gt ,1q2-otie& Contr Re' No.:6*5Y5i), D8g g xp Date: /40A Tukwila Business License No.:p0 _Oci9 um to Valuation of project (contractor's bid price): $ 15. 5O Describe the scope of work in detail: R vt0ye (1) ts"TIr2t, '-,,DFtaFt pLOK- ()K 'Is t IZEPLA-Cie 1Nl Tt} (2') NEW 11N175 — Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas Other: H:`,r\pplications\Forms-Applications On Line \2011 Applications \Mechanical Permit Application Revised 8-9-I Ldocx Revised: August 2011 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit n < 10,000 cfm �- Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500.000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Zk '(� Mailing Address: 'I2...0 2- Ntt S7 Date: /0 // 1�/5 Day Telephone: '/2S - /B 2 -o 8 T t 41434,0-ke / �nl - 9v 20 $ City / State Zip H:\Applications\Forms-Applications On Line\201 1 Applications \Mechanical Permit Application Revised 8-9-I Ldocx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $529.44 M15-0139 Address: 701 INDUSTRY DR Apn: 2523049008 $402.68 MECHANICAL $387.19 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $277.25 PLAN CHECK FEE R000.322.102.00.00 0.00 $77.44 TECHNOLOGY FEE $15.49 TECHNOLOGY FEE R000.322.900.04.00 0.00 $15.49 PG15-0124 Address: 701 INDUSTRY DR Apn: 2523049008 $126.76 GAS $121.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.38 TECHNOLOGY FEE $4.88 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6480 R000.322.900.04.00 0.00 $4.88 $529.44 Date Paid: Wednesday, October 21, 2015 Paid By: GB SYSTEMS INC Pay Method: CHECK 260345 Printed: Wednesday, October 21, 2015 2:25 PM 1 of 1 OrSYSTEMS City of Tukwila Department of Community Development 4/1/2016 JAE YOO 7202 NE 135 ST KENMORE, WA 98028 RE: Permit No. M15-0139 ANDOVER PARK EAST - BLDG 17 701 INDUSTRY DR Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/18/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/18/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M15-0139 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 AT PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0139 DATE: 10/21/15 PROJECT NAME: ANDOVER PARK EAST - BLDG 17 SITE ADDRESS: 701 INDUSTRY DR X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: C t Riv\ iqtt• Fire Prevention Building Division Public Works Structural Planning Division Permit Coordinator El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/22/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 11/19/15 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 G B SYSTEMS INC Horne lrucio en Espanol Contact: Page 1 of 2 Search L&I A-'i, Index Help Ie:Ty Secure L&O'I Safety Claims & Insurance Workplace Rights Trades & Licensing ashington State Department of abor & industries G B SYSTEMS INC Owner or tradesperson Principals BERG, GREGORY F, PRESIDENT Doing business as G B SYSTEMS INC WA UBI No. 601 353 544 7202 NE 175TH ST KENMORE, WA98028 425-482-0584 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties METAL FABRICATION License no. GBSYSI*088BS Effective — expiration 01/10/1992— 01/10/2017 Bond ................. CBIC Bond account no. 659569 Active. Meets current requirements. $6,000.00 Received by L&I Effective date 12/11/2001 12/17/2001 Expiration date Until Canceled Insurance. WEST AMERICAN INS CO Policy no. BKW53580469 $1,000,000.00 Received by L&I Effective date 01/07/2015 01/10/2010 Expiration date 01/10/2016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts .................................. No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601353544&LIC=GBSYSI*088BS&SAW= 11/20/2015 GAS NETER 701 705 fft L"JOO d 0313 GP-1I EXISTING 5 TON ROOFTOP UNIT 1" GAS GAS ' GAS GAS GAS _GAS 709 �GP-21 EXISTING 2-1/2 TON ROOFTOP UNIT GAS 1IMININIONIMMIMM rl GAS m. 713 0 ATE" GAS GAS GAS GAS 717 m 3/4"GAS1 GAS GAS GAS -110- GAS AC-4 4 TON NEW 75,000 BTU ROOFTOP UNIT AC-3 2 TON NEW 40,000 BTU ROOFTOP UNIT n 725 1/1 M1.0 ROOFTOP UNIT SCHEDULE - OLD NAME AREA MAKE MODEL # CFM ESP VOLT PH AMPS BTUH - HTG BTUH -CLG HP RPM SEER TONS WEIGHT REMARKS MAX OA MIN MCA FUSE INPUT BACKUP TOTAL SENS. AC-3 KENCO SUITE 717 BDP. 559EJ024 1,000 . 1,000 .30 208 10 24.4 30 N/A 4 KW 25.7 MBH 16.0 MBH .16 650 11.0 2 .435 1 AC-4 Z PEN SUITE 725 TRANE SACA-503-A 2,400 2,400 .50 208 30 41.2 50 N/A 11 KW 75.0 MBH 59.0 MBH 1.25 1,070 11.0 4 1,114 1 NOTES: 1. TO BE REMOVED, AND REPLACED WITH NEW CARRIER UNIT, SEE SCHEDULE BELOW ROOFTOP UNIT SCHEDULE - NEW NAME AREA MAKE MODEL 4E CFM ESP VOLT PH AMPS BTUH - HTG BTUH - CLG HP RPM SEER TONS WEIGHT REMARKS MAX . OA MIN MCA FUSE INPUT OUTPUT TOTAL SENS. AC-3 KENCO SUITE 717 CARRIER 48VL-B240403 932 932 .30 208 10 21.7 30 40.0 MBH 33.0 MBH 24.2 MBH 19.6 MBH 0.50 1,050 14.5 2 337 AC-4 Z PEN SUITE 725 CARRIER 48KCDA05A2A5-0AOA0 1,600 1,600 .50 .208 30 24.0 30 72.0 MBH 56.0 MBH 48.7 MBH 37.5 MBH 0.75 1,107 14.0 4 604 /,1 GAS PIPING CONNECTION DETAIL M1. SCALE: NiS M 1.0 SCALE: NTS Perlin No.. NAY .8 2016 REVISIONS No changes shall ho rn^+rlo to the scope of work with ' prior approval of Divisionwill submittal <<n n Wa: .l m;�y u-:.,�ude1 �c'ul;�ton�l n fC.. FILE COPY M I40112g Plan review approval is subject to errors and. GM; :11;;Cons. Approval Pf c onstruction documents does not the violation of any adopted code or ardina c;:,. I'::::: s:.; of approved Field Copy coins is ackri w ed -: : Bv: Date: ///41' City of Ti k i!a LAJTIL_L1tliu LIIVIOIUN ROOFTOP UNIT WEIGHT DIFFERENCE CHART SYSTEM NAME AREA MAKE MODEL # WEIGHT OLD AC-3 KENCO SUITE 717 BDP 559EJ024 435 AC-4 Z PEN SUITE 725 TRANE SACA-503-A 1,114 NEW AC-3 KENCO SUITE 717 CARRIER 48VL-9240403 337 AC-4 Z PEN SUITE 725 CARRIER 48KCDA05A2A5-0AOA0 .. 604 GB SYSTEMS, INC. HEATING * AIR CONDONING AIR AND WATER BALANCING 7202 NE 175th Kenmore, WA 98028 Phone 425*482*0584 Fox 425*482*0586 ostiC Y � ce a. ren z 4 w co oo CC �CO 0 CC t;i -§ o� N 4 2 E z E $ Utz _} 1 O : 0 Mechanical I' Electrical ,,` Plumbing pit:ls Piping Cry c T ukkgvi1a �•� f 1:'�< •n RECEIVED CITY OF TUKWILA OCT 2.1 2015 PERMIT CENTER 1 THESE DRAWINGS ARE THE SOLE PROPERLY OF GB SYSTEMS AND ARE NOT TO BE USED BY ANYONE ELSE WITHOUT EXPRESS WRITTEN PERMISSION. REVIEWED FOR CODE COMPLIANCE APPROVED. NOV 062015 s�r'J 1a . City of Tukwila BUILDING DIVISION Drawn by: JY Starling Date: 08/04/15 Checked by: GB Project Number. 167 North: Scale: 1 /8"=1'-0" CADD File: Sheet: FLOOR PLAN HVAC AND GAS • FLOOR PLAN HVAC AND GAS SCALE: 1 /8" = 1'- NOT FOR CONSTRUCTION