HomeMy WebLinkAboutPermit M15-0144 - POP GOURMET POPCORN - GAS/ELECTRIC AIR CONDITIONINGPOP GOURMET POPCORN 14550 INTERURBAN AVE S UNIT 100 M15-0144 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 3365901605 Permit Number: M15-0144 14550 INTERURBAN AVE S UNIT100 Issue Date: Permit Expires On: Project Name: POP GOURMET POPCORN 12/3/2015 5/31/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: SANFT LOUIE 6120 52ND AVE S , SEATTLE, WA, 98118 BILL ALSEPT 3903 SMITH AVE , EVERETT, WA, 98201 WILLIAMS MECHANICAL INC Address: 3903 SMITH AVE , EVERETT, WA, 98201 License No: WILLIMI088PA Lender: Name: Address: Phone: (425) 754-8759 Phone: (425) 303-0828 Expiration Date: 10/1/2017 DESCRIPTION OF WORK: INSTALL RTU GAS/ELECTRIC AC WITH DUCT SYSTEM TO NEW OFFICE SPACE. INCLUDE GAS PIPE AND EXHAUST VENTING. ALSO INCLUDE ECONOMIZER AND 7 DAY PROGRAMMABLE THERMOSTAT Valuation of Work: $13,000.00 Type of Work: NEW Fuel type: GAS Fees Collected: $363.48 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2014 2014 2014 2012 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local I s regulating construction or the performance of work. I am authorized to sign and obtain this developmen permit and agre,e to the conditions attached to this permit. Signature: Print Name: e%- z/Ut Loqm/t_l ( Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office tO')c-( s use only) MECHANICAL PERNHT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION / re - King Co Assessor's Tax No.: Site Address: f " - h�L/%L�kimA1lit-, /00 Suite Number: /00 Floor: Tenant Name: PO, Clovioit/ New Tenant: 5_v PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Address: City: State: Zip: Phone: Fax: Email: ❑..No MECHANICAL CONTRACTOR INFORMATION _/ Company Name: WaL/4/1, Mt C/7 Address: 1,0 j 5 ,/72j Av� ?�- City: ,iL.J� State:WA Zip f526y 7 Phone: c15.my, gr97 Fax:/7 Contr Reg No.:WILNI /Og$ M Exp Date: T Tukwila Business License No.: Valuation of project (contractor's bid price): $ 1 / vv Describe the scope of work in detail: /04" s/wt.... RrtJ Gas/� c 4.G fr ci- . 5yi 7en / 0 New 0//c/cv' .5-49ce - . bvez �e . 6 91 n/.6' Ara GVALff 1/11-7/ti4/9150 //tLz'e s 7 /Ay ' '*, tL- s/79k . Use: Residential: New ❑ Replacement 0 Commercial: New ®.-- Replacement ❑ Fuel Type: Electric ❑ Gas 112V Other: H:\Applications\Foms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 1 Furnace >I00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent 1 Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm / Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct / Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat/ Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERf11 Y THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWLS ��t (}R`� H RIZED AGE • Signature: Print Name: l vili/Are ,1 st,i7"" Mailing Address: 3 yvJ 5ii,, t /,b4r H:\Applications\For ns-Applications On Line1201 I Applications\Mechanical Penmt Application Revised 8-9-11.docx Revised: August 2011 bh Date: O 2 7— /5- Day Telephone: 2S' 79, g1�9 zwe City 91'20 State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT ( QUANTITY I PAID $363.48 M15-0144 Address: 14550 INTERURBAN AVE S UNIT100 Apn: 3365901605 $363.48 MECHANICAL $349.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $247.10 PLAN CHECK FEE R000.322.102.00.00 0.00 $69.90 TECHNOLOGY FEE $13.98 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6537 R000.322.900.04.00 0.00 $13.98 $363.48 Date Paid: Thursday, October 29, 2015 Paid By: WILLIAM ALSEPT Pay Method: CREDIT CARD 061654 Printed: Thursday, October 29, 2015 1:27 PM 1 of 1 IM SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit 4115 --4JY'/ PERMIT NO. CITY OF TUK'WILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � or�rer Type of Inspection:,,�! A1%r_i (Li/v- � Address: ,,� / 1 L/5"5"D —1/ti ei'Llr, fAV fie Date allgyt /4, Special Instructions:Date Wanted: lam' p.m. Requester: Phone No: pproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: I Inspector: T' C,snf�<z- Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee rust be paid at 6300 Southcenter Btvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ^ p Go (d-,4 � Type of Inspn , t/�eiri� Alit ) /+ Address: Y ! l/ j D Z//rur� e0 Date Ile J) 4 Special Instructions: Date Wanted: r � p.m. Requester: Phone No: �Appr.oved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: C,,fv,<- REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be \/paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD (;„�/J,` Retain a copy with permit �! 0f9 IN TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pro : Type of Ins ecti n: - mild Addr:-s. ) II2 J -4-1S t' Date ailed: IDS pec 1 nstructions: , Date Wanted: • •m. Reque6.tgr., /(- Phone No: ** Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: (,m- REINSPECTON FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 MIS O/1/g Project 6 �C�f �! �7 i�l i(2r� r-- i Type of.specti2ic7L,k /; '" Ke Date Adres:q sqo ,r, erwr4 6 ' Special Instructions: Date Wanted: J f , `IO p—.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: /Wor°-/ Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Projet7 Type of In section: R,el ate Ca d Special Instructions: /i Date Wanted: J 42-.` V p,m. Requester: ff Phone No: Approved per applicable codes. COMMENTS: Corrections required prior to approval. Inspector: REINSPECTION FEE REQUIRED. Prior to next inspeafion, fee must be / paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspectior INSPECTION RECORD Retain a copy with permit INSCTION NO. /l//.5, 61/9g PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 44ii"/Lle 7L Type of In ection: / Kok r- A. /ee, Address: 1 1/5-5-45 . wCee1" / Dat ailed P 00 i'27/9: Special Instructions: Date Wanted: / CIP.m. Requester: Phone No: proved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: Date: /,4 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. J C/e74.1:9 r h000 C Iy0) 00 0 CO CO Q: .i31E4d0 O0) OOO CZiV es. N 0 0 0 1-59�'r1� r� r AIRFLOWS Co OD COCO C. OO W1-0000 O m O00) CI) 0) 0 00 W s- .- r CV CD 000 VI CO O COO COn C. o00 C 00) 00) CO O))_ 0) W CD NCO O Oa- a- .- N 0 c .c 3 co. 0 CIL co OO gy.,�o.cmx aR CO a m c) Ems= mox•ec .CW ismm 01-2coz< wRQJJ ENGINEERING CKS ErO E a• CO CV _ O m O a N. O N o M� 0 1� C7 0 0 HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK 0 l- ap c . mL 01 W a 3 oa co co 0 c I'- mm Co N 000000)CD N01000 0000 CO V OCO C. COO O O 0OMCA0007 Nr Oo00nv 0 CO0n cD 1 0 a- cv CO CO 1� N CO 000 0 000 O 000 0 0 NO 0h 000000 0 ON ON000000 O .0a-.00000000 0 N O 000 0 Ov0 0 000000 00 CO r 0 N •lb �C m- O 0OO r- NO COO r' Co 000 o 00000 =0 CO 0 m.3.. 10N a— CO CCD CD O 0 0 r. N .10 00 c 0. 0. CO CO a MI 0 0 o o n 0 O ▪ D S O c 1L E 0- 0. 0) CD o 0 o m -- o To Y .Y 0 m c6 t6 co •C0 'p 6= j >WcQKil C7saLLQ EW (IJ Internal Loads CD CC) n 10 0. m Y 0 m Wx a m SS A co _ c .5E=m R j-G.111 0C 0Gc �O'-IJ0Ox0m CO iro m 0 C mmaQ o 13 0 L Ooo) a c� � ca 0. 200 �0. 13 Jam co maI >XQQQ'a%ca i O>QOWOwstc0= ) C9 -- OOO�r�NO00v Cn0 NCO CO CO N 000 CD 1H a00 O mL 000I101-.00000 N h0 C7 0) 00 0 0 o vvO) r` CD rnra) o 0 -. .... CO 0) 10 O N C0 CO CO r Nm m CO a -a- N C; r- r- Co. C 0 CO O O 0 0 O 0 O N C \ 000100000000)0 (0 Cp00 CO 007000000000 00 m i 1- O CO 0 co o. 0 • +- L 00 O 1010 C0000 a- CO CONC7 CD00000c0 o0000 N O CD Z p 2 tO W W COO 0) N O tD O O W O) naNO Fm Cpr N vc7r tti m o mco E .. E OOOOOW O 0) CD00 0) 000 OOi 0o 0 m = J CO CO CCOO CO 0) o a+ m Q aw O m tl) mJ t 00000001�000. CO hCVC') N 000 0 0 0 0 3 v v 0) CO v O .•' CO v CO 10J CO0)00 COO 00 CD O N 67 ; 0.+ 0 O. N r 0.- CO ci o EQ H� e a f0 O c Y O (5 mas 0'_'a 0 • O O it a I .ao co ac to yjCO ��0. a0 a J�cO�N O00 LL 11 0 it a cON000o.c o o c' o c0 c- O o c R coxxx.-N= wC0C-)ocneo 0-2 J_ �'d m Q Omm°rn'aUo 0W1-O mYn E° a)o Ea0au. 51t"2` 0 On T O ••• � W r p O= z m 0) m y C a Z� L d..t i+ a s ccYi)cYn�c�C�3aLLa5cn Ja�cn om m>xamaca W c O><0O11/141CC0 , Grand Total =_> 10 J° ZWLL 0 0 o W LE- J — Wa U m O a Z° W vo 1n0 0 00 0 0 C. Cn0 O 00 r- O O O O to 00 O 00 0) NO O 00 N 00 0 0o O N N x..0 w tp x 0 => 0 a ! = a 0 2Q a x0 I- e m m m '. (7� CD I..- CD 0 co 0 co O co 0 V'0 1-0 M CO CD 0 0 0 0 S 00 O IYE 0D0 O x m to 1- 0 CC to P- W NC O CIC CI. 0 0 c C6 m 0 111YORK RTv- / SUBMITTAL DATA Order #: Project: Project #: Location: Purchaser: Submitter: For: Quotation Date: 10/22/2015 WILLIAMS MECH BUDGET NUMBER RWS10222015-06 WASHINGTON WILLIAMS MECH-BILL YORK NW RYAN IS•-- 0 !Lig • REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 5 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 2.2015 PERMIT CENTER Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 10/29/2015 Date 10/22/2015 Project Name WILLIAMS MECH BUDGET NUMBER Project Number RWS10222015-06 Client! Purchaser WILLIAMS MECH-BILL 111YORK Submittal Summary Page Qty Tag # Model # Description 1 ZFO36NO8A2AAA4 3 Ton, York Sunline Single Packaged R-410A Air Conditioner, 13.0 SEER / 11.0 EER, Single Stage Cooling, 79 MBH Output Aluminized Steel, Single Stage Gas Heat, 1/2 HP Direct Drive Blower, 1" Throwaway Filters, 208/230-3-60, Microchannel Condenser Coil, Simplicity Lite Control, Galvanized Steel Drain Pan 1 RC0434 Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) 1 2EE04709224 Single Enthalpy Low Leak Jade Downflow or Horizontal Economizer w/o Barometric Relief 1 RD0410 Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted) Equipment start-up and commissioning by a factory trained technician is recommended. Contact your supplying distributor or sales representative for additional information & guidance. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 10292015 YORI( Small Sunline Single Package R-410A Air Conditioner Page: 3 Project Name: WILLIAMS MECH BUDGET NUMBER Unit Model #: ZFO36NO8A2AAA4 Quantity: 1 System: ZFO36NO8A2AAA4 Cooling Performance Total capacity 37.3 MBH Sensible capacity 27.9 MBH Refrigerant type R-410A Seasonal Efficiency (at ARI) 13.00 SEER Efficiency (at ARI) 11.00 EER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 60.4 °F Leaving WB temp. 58.1 °F Power input (w/o blower) 2.75 kW Sound power 81 dB(A) Gas Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 79 MBH Supply air 1314.7 CFM Heating input capacity (Max) 100 MBH Leaving DB temp. 115.6 °F Air temp. rise 55.6 °F SSE 80.8 % Stages 1 Supply Air Blower Performance Supply air 1314.7 CFM Ext. static pressure 0.64 IWG Unit static resistance 0.09 IWG Blower speed 925 RPM Duct location Bottom Motor rating 0.75 HP Actual required BHP 0.42 HP Power input 0.39 kW Elevation 0 ft. Drive type DIRECT Speed tap 5 Electrical Data Power supply 230-3-60 Unit min circuit ampacity 19.7 Amps Unit max over -current protection 25 Amps Dimensions & Weight Hgt 33 in. Len 83 in. Wth 45 in. Weight with factory installed options 533 lbs. Clearances Right 24 in. Front 32 in. Back 36 in. Top 72 in. Bottom 0 in. Left 36 in. Note: Please refer to the techguidefor listed maximum static pressures us n.�rt?.fc0 3 Ton • York Units are Manufactured at an ISO 9001 Registered Facility and Each Rooftop is Completely Computer -Run Tested Prior to Shipment. Unit Features • Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Salt Spray Test (ASTM B-117 Standards) • Through -the -Curb and Through -The -Base Utility Connections • Either Supply and/or Retum can be Field Converted from Vertical to Horizontal Configuration without Cutting Panels. • Full Perimeter Base Rails with Built in Rigging Capabilities • Galvanized Steel Drain Pan • Single Stage Cooling • Solid Core Liquid Line Filter Driers • Microchannel Condenser Coil • 79 MBH Output Aluminized Steel, Single Stage Gas Nominal Heat • 1/2 HP Direct Drive Blower • Unit Ships with 1" Throwaway Filters with a Standard Filter Rack That Will Accept up to 2" Filters • Replacement Filters: 2 - (15" x 20" x 1" or 2") and 1 - (14" x 25" x 1" or 2"). Unit accepts 1" or 2" wide fitters. • Single Point Power Connection • Short Circuit Current: 5kA RMS Symmetrical Standard Unit Controller: Simplicity Control Board • An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag, Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic and Fault Code Display. Allows all units to operate in the cooling mode down to 0 °F outdoor ambient without additional components or intervention. • Safety Monitoring - Monitors the High and Low -Pressure Switches, the Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition Failures, Safety Lockouts and Repeated Limit Switch Trips. Warranty • One (1) Year Limited Warranty on the Complete Unit • Five (5) Year Warranty - Compressors and Electric Heater Elements • Ten (10) Year Warranty - Aluminized Steel Tubular Heat Exchangers Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 10/29/2015 YORK Small Sunline Single Package R-410A Air Conditioner Page: 4 Project Name: WILLIAMS MECH BUDGET NUMBER Unit Model #: ZFO36NO8A2AAA4 Quantity: 1 System: ZFO36NO8A2AAA4 Factory Installed Options ZFO36NO8A2AAA4 Product Category: Product Identifier: Nominal Cooling Capacity: Heat Type and Nominal Heat Capacity: Airflow: Voltage: Installation Options: Additional Options: Z F 036 N08 A 2 A AA Product Generation: 1 RC0434 - Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) (86.0 Ibs) 2EE04709224 - Single Enthalpy Low Leak Jade Downflow or Horizontal Economizer w/o Barometric Relief (50.0 Ibs) 1 RD0410 - Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted) (6.0 Ibs) 4 York Sunline Single Packaged R-410A Air Conditioner 13.0 SEER / 11.0 EER 3Ton Single Stage Cooling 79 MBH Output Aluminized Steel, Single Stage Gas Heat 1/2 HP Direct Drive Blower 1" Throwaway Fitters 208/230-3-60 Microchannel Condenser Coil Simplicity Lite Control Galvanized Steel Drain Pan Field Installed Accessories Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 10292015 Project Name: WILLIAMS MECH BUDGET NUMBER ZE036NO8A1AAA4 T c W 3 C5 CL Consolidated Drawing 4- Z an 0 mm,0 N 0 .O N N 0 N N. aaD N COOm CO N T 0 .O .O 0 00 01 .0 ^a°J0^ 00 CO oct I, 013 CD Ws CO N N N N N N N N N CD a 4-11 CO N N CD N4-1 N 00 CO N ^ 01 N N CD N 0 N 01 art Ln 01 N d N 01 N an m 0 m 141 N m M u m co 1-4 frl Cr, IJI m W u 01 N CO LO N CO N J ON to N an ark 4-1 04 N a ara N Q mtra m :O fel 1-1 rra m 4-1 1711 0 CO m e rrl e V 4-1 m 4-1 .0 m e ro w o1 01 u Q an CD N N • CO 00 N N V N 0 1.0 • 0 N Cr. C CD CO N ♦a1 N 01 LO N CO CD N m CD N 00 LIN 0 CO a ^ 0 0 tO.1 ^ V 00 m N 0 m u N X CO an 0 0 co an art r^+1 • co m m v 0 CO CO 0 01 m O1 a� 1^+1 .0 m a 4-4 0 4-1 0 a CO m 1n m eV 00 i0 O m 01 0 01 01 0 rn 01 N N 0.1 m 01 0 m 041 40 N u 00 Q 4-1 .--. 00 CO u 40 CO CO an 10 O1 u co u CD an an GO OD u Cis LLI r COOLING ONLY UNITS. LI- N 1 v N Lrt N .0 CC rn CC v 00 0 pp In N� co a 0- X v m Cr:.acr Q n u DJ CO w . 0�' 111 tX r.n 1 Qi 1i.-. of va mm 01 0Opp2 �.--.! O cc 2 ¢ Q C .,On..O 0- ce N Y W z ac cc a -a cc z¢ Q6N 2 m Q wO au pa.- 0 ON N N. N N J 0 W 0 d0 H 01 g 22 J 22au Vl7 S v1OK= Q cOW z z Da ...-.2 z•-• 0.1 Qrz1 a O`OD- v 0 HO.- 00 �1--Ooc 2crw14.1u' - au 00 - wV2.¢..w1aVi0 OwQ 2 Q .Oi104 w2 12-1w0 F VI20v1 ann22 1--z Onw 2M yQz 0 X20-10V= -A2 -Eww J3 VO 0 JH¢ W VV O1 ^ 3H O.n0Q01 V SH d 12-1 Q O20HO2m ¢F-12-10w . 2 m 0 OOr wO O>c Q Q 2 a02H wH2 Qr 1-w0 o3 Ca_ 42/-221_w wS arl K pp J Ca LLm ON ON act mNGtGt m ¢t,� z¢ z ¢ w= CD Oe'1 CO N0N VH I- Ca Q 0Ow 0 .n 2 O0001001 en O1 N V W u¢p OH>�C • w OWr }1J1-1 2 021-H ¢2 0 dO r.nw QF- 00 0, W QWcf.00V NN.0 NOKd - 000O art Q.-�.0I-O 0- NNrt1N1nNr/1 i� QV1}0 2O2..V' 020 VI rJw +Q 2J32 X 32 •- 20 2 OO Jl0O 2 HH.n� c OQw-- WOOO2w al_ 1--2 O ^a O SX0w OD V Vpr NV/-J Ov1WH0 J} 2Q1-O V WZ Z ,0 viH -- 360c VO 0J0H -an-0 -- FQ.-O0000 2 23 1-4¢2� 21-0 r 1- -• 02 V JV 0 022 o 022. 2 OS SF 2 - - . 0 Q11_ W1n O2JWNOw 10-1 -171r- O W F- r2.�c V1 wr0 VJ ZHw CC 0CI. 23O OOF-2WErV11- V O WHCJ c Hm 000 Co 0 d'Hp1-12 H0_HX 3E V 0C H V 040 Fr 0000 --a0 00001000 N 1+1 z 01 CZ C001 DIRECTION OF AIRFLOW CENTER OF GRAVITY cCO Q • m N • N CO°.. CO m cr. cc, N cGO m act,N-1 • \ f iN_. , NC CD i mT -13 cn 01w N cc co r"n 01 N u Printed 10/22/2015 ect to change without notice. Check local codes. Information is su Unitary Sales Tool v1.5.9.0 i�YORK Small Sunline Single Package R-410A Air Conditioner Page: 6 Project Name: WILLIAMS MECH BUDGET NUMBER Unit Model #: ZFO36NO8A2AAA4 1 v o 1 I r I r 1 I I I 1 r 1 r I ! FIELD -SUPPLIED DISCONNECT SWITCH TO POWER SUPPLY T CONDENSATE TRAP CONTROL WIRING TO INDOOR THERMOSTAT ROOF JACK INSTALLATION 1 i 1 I1 1 RETURN AIR DUCT 1 i SUPPLY MR DUCT r� ROOF CURB INSTALLATION SLAB ON GROUND INSTALLATION ta 11 QI a S i I I ROOF CURB • MANUAL GAS SHUT-OFF VALVE TO GAS SUPPLY LINE Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 10292015 IYORK Small Sunline Single Package R-410A Air Conditioner Page: 7 Project Name: WILLIAMS MECH BUDGET NUMBER Unit Model #: ZFO36NO8A2AAA4 CONTACTOR ' sY Imo 1 r I GR ND LUG TYPICAL POWER WI=EIPC FIELD -SUPPLIED DISCONNECT ' r-- , SINGLE - r > PHASE -O- L.O- POWER CONTACTOR 1 L j SUPPLY GROUND L REFER TO THE ELECTRICAL DATA TABLES TO SIZE THE DISCONNECT SWITCH, OVER CURRENT PROTECTION AND WIRING. LUG I L L ,,zrcTnm' i►q.awnuxg gpasi FIELD -SUPPLIED DISCONNECT r 1 -p. 1 _r_ THREE -t- - - -> PHASE $' 0--L 3 POWER L J SUPPLY TYPICAL COOL/HEAT CONTROL WIRING COOLING ONLY (24 VOLT THERMOSTAT) THERMOSTAT' UNIT TERMINAL TERMINALS STRIP TB1 24 VOLT TRANSFORMER 124 VOLT THERMOSTAT. TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING. USE A 2 STAGE COOLING THERMOSTAT. COOLING / HEATING (ELECTRONIC THERMOSTAT) MULTI STAGE THERMOSTATI TERMINALS ADD JUMPER ADD JUMPER NOT D 4 UNIT TERMINAL STRIP TB1 2— TO REMOTE SENSOR IF USED 24 VOLT TRANSFORMER ELECTRONIC PROGRAMMABLE THERMOSTAT TYPICAL. SECOND STAGE COOLING IS NOT REQUIRED ON UNITS LESS ECONOMIZER. 1 SECOND STAGE HEATING IS ONLY REQUIRED ON UNrrS WITH A TWO STAGE ELECTRC HEATER OR 2 STAGE GAS HEAT. . REMOVE JUMPER J2 FROM TERMINALS 4 AND 9 ON JUMPER PLUG CONNECTOR P6 ON UNITS WITH ECONOMIZER. TERMINALS Al AND A2 PROVIDE ARELAY OUT -PUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE THERMOSTAT SWITCHES TO THE SET -BACK POSITION. COOLING / HEATING (24 VOLT THERMOSTAT) THERMOSTATI TERMINALS UNIT TERM NAL STRIP TB1 ADD JUMPER 24 VOLT TRANSFORMER '24 VOLT THERMOSTAT. TO CONTROL THE ECONOMIZER ON THE SECOND STAGE COOUNG OR TO HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT, USE A 2 STAGE COOL AND HEAT THERMOSTAT. COOLING / HEATING (ELECTRONIC THERMOSTAT) SINGLE STAGE THERMOSTAT' TERMINALS UNIT TERMINAL 24 VOLT TRANSFORMER 1ELECTRONIC PROGRAMMABLE THERMOSTAT TYPICAL. TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING. USE A 2 STAGE COOL AND HEAT THERMOSTAT. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 10/29/2015 �YORIC Small Sunline Single Package R-410A Air Conditioner Page: 8 Project Name: WILLIAMS MECH BUDGET NUMBER Unit Model #: ZE036NO8A1AAA4 Quantity: 1 System: ZE036NO8A1AAA4 BACK OF UNIT SUPPLY' AIR RETURN' AIR 37-114" DUCT SIZES: Supply Air = 19" x 19" Retum Air = 19" x 19" 1RC0434 Roof Curb 2" TYP_ DUCT SUPPORT RAILS iRC0434 Roof Curb Dimensions 73" COMPRESSOR AND CONDENSER END OF UNIT FRONT OF UNIT Supply and Retum Air (including duct support rails) shown are typical for bottom duct applications. For location of horizontal duct applications (on back of unit). refer to Unit Dimensions details. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 10/222015 Date 10/22/2015 Project Name WILLIAMS MECH BUDGET NUMBER Project Number RWS10222015-06 Client / Purchaser WILLIAMS MECH-BILL LIYORK Guide Specification Summary Page Product Series Models and Unit Tags !Small Sunline ZE036NO8AIAAA4 Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 10222015 YORK Guide Specification for York Sunline Page: 10 GENERAL Units shall be manufactured by Johnson Controls Unitary Products in an ISO 9001 certified facility. York Sunline units are convertible single package units. Although the units are primarily designed for curb mounting on a roof, they can also be slab -mounted at ground level or set on steel beams above a finished roof. Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory -mounted options and field -installed accessories to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with holes in the four comers for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power exhaust are suitable for bottom duct connections only. For bottom duct, remove the sheet metal panels from the supply and retum air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. All non -Scroll compressors include crankcase heaters and all compressors have intemal pressure relief. Every refrigerant circuit includes a liquid line filter -drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch. The unit control circuit includes a 75 VA transformer, a 24-volt circuit breaker and a relay board with a compressor lockout circuit, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All models are CSA listed. All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements carry a 5- year warranty. Aluminized steel and Stainless steel tubular heat exchangers carry a 10-year warranty. DESCRIPTION Units shall be factory -assembled, single packaged, Electric Cooling/Gas Heat, Electric Cooling/Optional Electric Heat, Heat Pump/Optional Electric Heat are designed for outdoor mounted installation. The 3 ton, 4 ton and 5 ton units shall have minimum SEER rating of 13.0 with heat pumps having a 7.7 H.S.P.F. The 6 Ton Cooling only or Cooling with Electric Heat shall have 11.2 EER, 6 Ton Cooling with Gas Heat shall have 11.0 EER. They shall have built-in field convertible duct connections for down discharge supply/retum or horizontal discharge supply/retum, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R-410A refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units the cooling performance shall be rated in accordance with DOE and AHRI test procedures. Units shall be CSA listed, classified to ANSI Z21.47, UL 1995/CSA No. 236 standards. UNIT CABINET Unit cabinet shall be constructed of galvanized steel, with exterior surfaces coated with a non -chalking, powdered paint finish, certified at 1000 hours salt spray test per ASTMB117 standards. Indoor blower section shall be insulated with a minimum 1/2" thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the fumace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be "large" size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 1" filters shall be fumished and be accessible through a removable access door, sealed airtight. Units filter track shall be designed to accommodate either 1" or 2" fitters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air by-pass of the coils. Condensate pan shall be intemally sloped and conform to ASHRAE 62-89 self -draining standards. Condensate connection shall be a minimum of 3/4" I.D. female and be a ridged mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY The indoor fan shall be a factory installed direct -drive or belt -drive assembly that includes an adjustable pitch motor pulley. Job site selected (B.H.P.) brake horsepower shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double -inlet type with forward -curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fan shall be of the direct -driven propeller type, discharge air vertically, have aluminum blades riveted to a corrosion resistant steel spider bracket and shall be dynamically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings, intemally protected against overload conditions and staged independently. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 1022/2015 YORI( Guide Specification for York Sunline Page: 11 REFRIGERANT COMPONENTS Compressors: a. Shall be intemally protected with intemal high- pressure relief and over temperature protection. b. Shall have intemal spring isolation and sound muffling to minimize vibration and noise, and be extemally isolated on a dedicated, independent mounting. Coils: a. Evaporator coils shall have aluminum plate fins mechanically bonded to seamless intemally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator coils shall be of the direct expansion, draw thru design. c. Condenser coils shall have aluminum plate fins mechanically bonded to seamless intemally enhanced copper tubes with all joints brazed or Micro -Channel aluminum tube, aluminum fins. d. Condenser coils shall be of the direct expansion, draw thru design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent fixed -orifice or thermally operated expansion devices. b. Filter drier/strainer to eliminate any moisture or foreign matter. c. Accessible service gage connections on both suction and liquid lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. d. The refrigeration system shall provide at least 15°F of sub -cooling at design conditions. Unit Controls: a. Unit shall be complete with self-contained low -voltage control circuit protected by a resettable circuit breaker on the 24-volt transformer side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor. c. Loss-of-charge/Low-pressure switch. d. High-pressure switch. e. Freeze -protection thermostat, evaporator coil. f. Unit shall incorporate "AUTO RESET" compressor over temperature, over current protection. g- Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. h. Unit control board shall have on -board diagnostics and fault code display. i. Standard controls shall include anti -short cycle and low voltage protection, and permit cooling operation downto0°F. Control board shall monitor each refrigerant safety switch independently. k. Control board shall retain last 5 fault codes in non volatile memory which will not be lost in the event of a power loss. GAS HEATING SECTION (SINGLE STAGE) Shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. Venter wheel shall be constructed of stainless steel for corrosion resistance. The heat exchanger shall be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 25°F. Burners shall be of the inshot type, constructed of aluminum coated steel and contain air mixture adjustments. All gas piping shall enter the unit cabinet at a single location through either the side or curb without any field modifications. Integrated control boards shall provide timed control of evaporator fan functioning and bumer ignition. Heating section shall be provided with the following minimum protection. a. b. c. d. e. Primary and auxiliary high -temperature limit switches. Induced draft motor speed sensor. Flame roll out switch. Flame proving controls. If any of the above safety devices trip, a LED (light - emitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage, 40% Capacity 2nd Stage. UNIT OPERATING CHARACTERISTICS Unit shall be capable of starting and running at 125°F outdoor temperature, exceeding maximum load criteria of AHRI Standard 210/240. The compressor, with standard controls, shall be capable of operation down to 0°F outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up (Gas heat only). Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 10/22/2015 YORK Guide Specification for York Sunline Page: 12 ELECTRICAL REQUIREMENTS All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES • Compressor 5 Years • Heat Exchanger 10 Years • Electric Heat Element 5 Years • Other Parts 1 Year ADDITIONAL FACTORY INSTALLED OPTIONS FIELD INSTALLED OPTIONS • Roof Curb — 14" high, full perimeter curb with wood nailer (shipped knocked -down). • Barometric Relief Damper — This damper accessory can be used to relieve intemal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the retum air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 10222015 City of Tukwila Department of Community Development November 13, 2015 BILL ALSEPT 3903 SMITH AVE EVERETT, WA 98201 RE: Correction Letter # 1 MECHANICAL Permit Application Number M15-0144 POP GOURMET POPCORN - 14550 INTERURBAN AVE S #100 Dear BILL ALSEPT, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" to be stamped and signed. [Electronic copies shall not be approved.] (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Show where roof access is located. If access is over 16 feet from the finish grade a roof access ladder shall be provided. If located within 10 feet of the roofs edge, a guard shall be provided, see item #2. (IMC 306.5) 2. The new RTU is shown to be within eight feet of the buildings edge. Guards shall be provided where appliances, equipment, fans, roof hatch opening or other components that require service are located within 10- feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30-inches above the floor, roof or grade below. The guard shall be constructed so as to prevent the passage of a 21-inch-diameter sphere. The guard shall extend not less than 30-inches beyond each end of such appliances, equipment, fan or component. Show a guard with details or relocate the mechanical unit. (2012 IMC 304.112012 IBC 1013.6 & 1013.7) Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 433-7165. Sincerely, Rachelle Ripley Permit Technician File No. M15-0144 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0144 DATE: 11/17/15 PROJECT NAME: POP GOURMET POPCORN SITE ADDRESS: 14550 INTERURBAN AVE S - SUITE 100 Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: MK/ " Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator 11 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 11/19/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 12/17/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0144 DATE: 10/29/15 PROJECT NAME: POP GOURMET POPCORN SITE ADDRESS: 14550 INTERURBAN AVE S - SUITE 100 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: OOP- (0-(I t Building Division Public Works Ijk Fire Prevention Structural Planning Division Permit Coordinator III PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 11/0315 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 12/01/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: )/ / Plan Check/Permit Number: ❑ Response to Incomplete Letter # Response to Correction Letter # l Pi M)5 -01 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: POf 6Oo%, g% jg/CokV Project Address: % 11 5 l 6 %/VTMOXi3/lj/ ri) Ui S /Ov Contact Person: g JL. A� 7L.S / Phone Number: '2 5 7 S9 S 7 Summary of Revision: (O/6A qi0.-/ TO 3H E7 e_ 6 .5 Nvw/A/ - 7/1Z CoAg G; /ow 70 341FI-T /7 - ?f bt-»JN - l /ipr- —WE l S EA/o v 6/4 L-r/1A9,�CU' 7/IL= % (/ /9,v„9 CITY OF TUKWILA fat /7 MS PERMIT t:RlTER Sheet Number(s): /14 7 %�,V/� H 6 "Cloud" or highlight all areas of revision including date of revis Received at the City of Tukwila Permit Center by: T �-- Entered in TRAKiT on I 1---( (� WILLIAMS MECHANICAL INC Hone lnicio en .Espafiol Contact Page 1 of 2 A-7,, Index Help biy Secure.1. &I. Safety Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & Industries WILLIAMS MECHANICAL INC Owner or tradesperson Principals WILLIAMS, BRADLEY PATRICK, PRESIDENT WILLIAMS, DEBORAH KAY, SECRETARY WILLIAMS, DEBORAH KAY, TREASURER WILLIAMS, DEBORAH KAY, AGENT ZUCCARINI, MICHAEL J, AGENT (End: 01/01/1980) Doing business as WILLIAMS MECHANICAL INC WA UBI No. 601 413 863 3903 SMITH AVE EVERETT, WA98201-4549 425-303-0828 SNOHOMISH County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. WILLIMI088PA Effective — expiration 10/01/1992-10/01/2017 Bond Merchants Bonding Co (Mutual) Bond account no. WA33987 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 09/23/2014 10/01/2014 Expiration date Until Canceled Bond history Insurance .................... Allied Property & Cas Ins Co $1,000,000.00 Policy no. ACP3007325217 Received by L&I Effective date 10/13/2015 09/30/2015 Expiration date 09/30/2016 Insurance history Savings ................... https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601413 863 &LIC=WILLIMI088PA&SAW= 12/4/2015 •1•1001. .01111111. F007 TALL ItvAlLi *10" Rio-! mono movE0 er 1 NEW HVAC UNIT PLACE OPENING PER EXISTING STRUCTURAL JOISTS v MECH UNIT BODY DAMPENING MATERIAL PER MANUF. FACTORY NAILER STRIP (2X) GALV. MTh FLASHING — TYP. ATTACH TO CURB AS REM) BY MANUF. GALV. MIL COUNTER FLASHING — TYP. FACTORY CURB ATTACH PER MANUFACTURER ROOFING MEMBRANE UP & OVER .CURB ATTACH ROOF'G TO NAILER AT TOP OF CURB 18" OC, MIN 2 PLACES EA. SIDE SEE STR(JCT. FOR TYP. OPENING• SUPPORT AND ROOF PENETRATIONS ROOF STRUCTURE ROOF BLOCKING MECH. CURB DETAIL 1"4-0" • No changes shall be made tr) of work t^fithout prior 9. 1 ri Building UV :3•.'"!", roquire r -,17:':7:1 • • LIcnionalr, FILE C'71 Permit No. • Plan review approval i ii Approval of construction the violation of any ador- . of approved Fie: 0.0.1.1111•••••••• SEPARATE PERMIT mcnan:cc, )2r Electrical )21 Piurnbing . p Gas Piping Ci:j of Tuki.v!la BlYt.ri D'AffSfON 411•11.M. and omissions. • • riot authorize TAinance. Receipt is acknowledged: REVIEWED FOR CODE COMPLIANCE APP OVED NOV 2 5 2015 frd 1212- City of Tukwila BUILDING DIVISION REMARKS TI PER IT SUB ITTAL ) 1 r. k ui 0 - \, tr Zi \ \) uJ REGISTERED • ARCH CT WILUAM 'FULLER STATE OF WASHINGTON six ta RECEIVED CITY OF TUKWIL4 •NOV 1 7 26;5 PERMIT CENTER Williams Mechanical 3903 Smith Ave Everett, WA 98201 M-4 e`• 1" Gas line Connect to existing tap 1•011.10 410111111 1111111••• 18x12 18x12 up to RTU-1 Supply and return Insulate per code ./ • •,• • • 3 ..• 0000000 .• • • STAIRS TO STORAGE AB rr I 1 HI (WAREHOUSE\ \RESTROOM/ / 2x2 Iayin return 600 CFM 12" 4" vent up to roof ( RESTRO • Yi Ceiling fans by other 2x2 Iayin return 300 CFM 10" Typ of 2 LEVEL 1 FLOOR PLAN 3/16" = 1'-0" • TOP OF PAINTED GUARDRAIL TOP OF PAINTE HANDRAIL . 4 NOSING STAIR SECTION 1/2- = STAIR FRAMING PER STRUCTURAL CLOSED RISER • . . DEMISING WALL TOP OF PAINTED GUARDRAIL: 1-Y2" x 1-h" x HSS 1 4/2" 0 PAINTED HANDRAIL ENDS OF HANDRAIL TO TURN DOWN : ' • • 3'-2' x x HSS PAINTED STANCHIONS 3'-8" 3". 0 PAINTED ROD WELDED TO STANCHIONS BOLTED CONNECTION TO STRINGER PER STRUCTURAL CENTER PLATE ON STAIR TREAD CLEAR DIMENSION BETWEEN RODS TO BE LESS THAN 4", TYP. STAIR ELEVATIO 1/2" = 1 1/2" DIA. MIL GUARDRAIL T.O. PAkAPET 101-0" • 3/4" PLYWkOD "DECKIG" 0/ FRAMING PER 'ERUCT. GUARD RAIL EQ. SPACED VERT. 1 1/2"0 GALV. PIPE POSTS (7) EQ. SPACED 1"0 GALV PIPE RAILS ••••••.. ATTACHED GUARDRAIL TO MEZZANINE TOP SILL PLATE PER STRUCTURAL DRAWING ALL PIPE RAIL'GS JOINTS TO BE WELDED ALL AROUND AND GROUND SMOOTH PRIOR TO HOT DIP GALVANIZING TYP. GUARDRAIL @ MEZZ. 1 /2" =-- 1'-0" 13'-9" SLOPING 42" HIGH WALL ABOVE STAIR TREAD MEZZANINE PLAN (941 SF) EL. +14'-0" MEZZANINE PLAN 1 /4"=r-0" • REVIEWED FOR CODE COMPLIANCE APPROVED 111111.11111•••••1•SI NOV 2 5 2015 City of Tukwila BUILDING DIVISION • RECEIVED CITY OF TUKWILA OCT 2.a 2015 PERMIT CENTER IF THIS DRAWING IS NOT 24" X 36" IT IS A REDUCED PRINT. • Existing tap with valve NS\ wPEER L- • ✓ srrrrrrsrrrrrrrr rrrrrrrrrrrrrrrr rrrrrrrrrrrrrrrrrrr rrrrrrrrrrrrir ■ r—, . r--1 r—`1 r—n r--1 I I ■ I• 1 I I • 1 .1 I I I I 0 I I I I I I I I • ■ �a d Point of connection 1" gas line 21b • 3/4" gas line to office Existing • Existing Unit Heater •° - 75,000 BTU • • • I DEMISING WALL e TENANT A00 L i 1 r--1 r—n ri r—n r—n ri I I 1 1 I I 1 1 I I 1 I I I 1 I I I 1 I I I I I I ^ I I 1 I • II• I I 1 1 . 1 1 L—J L—J ■ L.—J L—J L—J L—J II ■ ■ • All gas line below roof ■ • new and existing s ■ o 1 1 1_ 1 s • 1 1 1 1 • 1 1 1 I • L.-J L—J II ■ II �— r--I r--1 I I 1 I II II I 1 I' I L— J L — J 1111111 " m 3/4" gas line up to RTU-1 on roof 100,000 BTU L 1 1 1 1 • - Gas line from existingtapto RTU-1 POP GOURMET suite A-iOO -000 Existing 2Ib Gas meter space A-100 AL-425 MAOP 10 PSI ANSI Class 400 14Y755448 000 Separate meters for other suites. 0 FOR FLOOR STRUCTURE, REFER TO APPROVED STRUCTURAL DRAWING DATED 19/09/2014 UNDER PERMIT NUMBER D11-060 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 5 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 17 2015 REMARKS T.I. PERMIT SUBMITTAL I ¢ co o- 0---- I orb z 16/7 gl= toon ■ DC W Lam REGISTERED ARCHITECT WIW ' • UR FULLER STATE OF WASHINGTON Job Numbs: 1005 0.032 Date MAY 15, 2015 �r►c�al n a10 Propet Mor : 'UAW FULLER VAHID KHASTOU Gas Line AIRCHITICTs