HomeMy WebLinkAboutPermit M15-0144 - POP GOURMET POPCORN - GAS/ELECTRIC AIR CONDITIONINGPOP GOURMET POPCORN
14550 INTERURBAN AVE S
UNIT 100
M15-0144
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
3365901605 Permit Number: M15-0144
14550 INTERURBAN AVE S UNIT100 Issue Date:
Permit Expires On:
Project Name: POP GOURMET POPCORN
12/3/2015
5/31/2016
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
SANFT LOUIE
6120 52ND AVE S , SEATTLE, WA,
98118
BILL ALSEPT
3903 SMITH AVE , EVERETT, WA,
98201
WILLIAMS MECHANICAL INC
Address: 3903 SMITH AVE , EVERETT, WA,
98201
License No: WILLIMI088PA
Lender:
Name:
Address:
Phone: (425) 754-8759
Phone: (425) 303-0828
Expiration Date: 10/1/2017
DESCRIPTION OF WORK:
INSTALL RTU GAS/ELECTRIC AC WITH DUCT SYSTEM TO NEW OFFICE SPACE. INCLUDE GAS PIPE AND EXHAUST
VENTING. ALSO INCLUDE ECONOMIZER AND 7 DAY PROGRAMMABLE THERMOSTAT
Valuation of Work: $13,000.00
Type of Work: NEW
Fuel type: GAS
Fees Collected: $363.48
Electrical Service Provided by: PUGET SOUND ENERGY
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
Permit Center Authorized Signature:
2012
2012
2012
2012
2012
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
Date:
2014
2014
2014
2012
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local I s regulating construction or the performance of work. I am authorized to sign and obtain this
developmen permit and agre,e to the conditions attached to this permit.
Signature:
Print Name:
e%- z/Ut
Loqm/t_l (
Date:
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: Readily accessible access to roof mounted equipment is required.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
9: ***MECHANICAL PERMIT CONDITIONS***
10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
11: Manufacturers installation instructions shall be available on the job site at the time of inspection.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
0703 MECH EQUIP EFF
1800 MECHANICAL FINAL
0609 PIPE/DUCT INSULATION
0705 REFRIGERATION EQUIP
0701 ROUGH -IN MECHANICAL
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
(For office
tO')c-( s
use only)
MECHANICAL PERNHT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
/ re -
King Co Assessor's Tax No.:
Site Address: f " - h�L/%L�kimA1lit-, /00 Suite Number: /00 Floor:
Tenant Name: PO, Clovioit/ New Tenant:
5_v
PROPERTY OWNER
Name:
Address:
City:
State:
Zip:
CONTACT PERSON — person receiving all project
communication
Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
❑..No
MECHANICAL CONTRACTOR INFORMATION
_/
Company Name: WaL/4/1, Mt C/7
Address: 1,0 j 5 ,/72j Av�
?�- City: ,iL.J� State:WA Zip f526y
7
Phone: c15.my, gr97 Fax:/7
Contr Reg No.:WILNI /Og$ M Exp Date:
T
Tukwila Business License No.:
Valuation of project (contractor's bid price): $ 1 / vv
Describe the scope of work in detail: /04" s/wt.... RrtJ Gas/� c 4.G fr ci-
. 5yi 7en / 0 New 0//c/cv' .5-49ce - . bvez �e . 6 91 n/.6'
Ara GVALff 1/11-7/ti4/9150 //tLz'e s
7 /Ay ' '*, tL- s/79k .
Use: Residential: New ❑ Replacement 0
Commercial: New ®.-- Replacement ❑
Fuel Type: Electric ❑ Gas 112V Other:
H:\Applications\Foms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1I.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
1
Furnace >I00k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
1
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
/
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
/
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat/
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERf11 Y THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWLS ��t (}R`� H RIZED AGE •
Signature:
Print Name:
l vili/Are ,1 st,i7""
Mailing Address:
3 yvJ 5ii,, t /,b4r
H:\Applications\For ns-Applications On Line1201 I Applications\Mechanical Penmt Application Revised 8-9-11.docx
Revised: August 2011
bh
Date: O 2 7— /5-
Day Telephone: 2S' 79, g1�9
zwe
City
91'20
State Zip
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS I
PermitTRAK
ACCOUNT ( QUANTITY I
PAID
$363.48
M15-0144 Address: 14550 INTERURBAN AVE S UNIT100 Apn: 3365901605
$363.48
MECHANICAL
$349.50
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$247.10
PLAN CHECK FEE
R000.322.102.00.00
0.00
$69.90
TECHNOLOGY FEE
$13.98
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R6537
R000.322.900.04.00
0.00
$13.98
$363.48
Date Paid: Thursday, October 29, 2015
Paid By: WILLIAM ALSEPT
Pay Method: CREDIT CARD 061654
Printed: Thursday, October 29, 2015 1:27 PM 1 of 1
IM SYSTEMS
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
4115 --4JY'/
PERMIT NO.
CITY OF TUK'WILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
� or�rer
Type of Inspection:,,�!
A1%r_i (Li/v-
�
Address: ,,� /
1 L/5"5"D —1/ti ei'Llr, fAV fie
Date allgyt
/4,
Special Instructions:Date
Wanted:
lam'
p.m.
Requester:
Phone No:
pproved per applicable codes. 0 Corrections required prior to approval.
COMMENTS:
I
Inspector:
T' C,snf�<z-
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee rust be
paid at 6300 Southcenter Btvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project: ^
p Go (d-,4
�
Type of Inspn ,
t/�eiri�
Alit
) /+
Address: Y
! l/ j D Z//rur�
e0
Date Ile J)
4
Special Instructions:
Date Wanted:
r
�
p.m.
Requester:
Phone No:
�Appr.oved per applicable codes. LJ Corrections required prior to approval.
COMMENTS:
Inspector:
C,,fv,<-
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
\/paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD (;„�/J,`
Retain a copy with permit �! 0f9
IN TION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 438-9350
(206) 431-3670
Pro :
Type of Ins ecti n:
- mild
Addr:-s.
) II2 J -4-1S t'
Date ailed:
IDS
pec 1 nstructions: ,
Date Wanted:
•
•m.
Reque6.tgr., /(-
Phone No: **
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspector:
(,m-
REINSPECTON FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
MIS O/1/g
Project 6
�C�f �! �7 i�l i(2r�
r-- i
Type of.specti2ic7L,k
/; '" Ke
Date
Adres:q
sqo ,r, erwr4 6 '
Special Instructions:
Date Wanted:
J f
, `IO
p—.m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
/Wor°-/
Inspector:
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSION NO.
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 438-9350
(206) 431-3670
Projet7
Type of In section: R,el
ate Ca d
Special Instructions:
/i
Date Wanted:
J 42-.`
V p,m.
Requester:
ff
Phone No:
Approved per applicable codes.
COMMENTS:
Corrections required prior to approval.
Inspector:
REINSPECTION FEE REQUIRED. Prior to next inspeafion, fee must be /
paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspectior
INSPECTION RECORD
Retain a copy with permit
INSCTION NO.
/l//.5, 61/9g
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
44ii"/Lle 7L
Type of In ection: /
Kok r- A. /ee,
Address:
1 1/5-5-45 . wCee1"
/
Dat ailed
P 00 i'27/9:
Special Instructions:
Date Wanted:
/ CIP.m.
Requester:
Phone No:
proved per applicable codes. LJ Corrections required prior to approval.
COMMENTS:
Inspector:
Date: /,4
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
J C/e74.1:9
r
h000
C Iy0) 00 0
CO CO
Q: .i31E4d0 O0) OOO
CZiV es. N 0 0 0
1-59�'r1� r� r
AIRFLOWS
Co OD COCO C. OO W1-0000
O m O00) CI) 0)
0 00 W s- .- r CV
CD
000 VI CO O COO COn C. o00
C 00) 00) CO O))_ 0) W CD NCO
O
Oa- a- .- N
0
c
.c 3 co.
0 CIL co OO gy.,�o.cmx aR CO
a m c) Ems= mox•ec .CW ismm
01-2coz< wRQJJ
ENGINEERING CKS
ErO
E a•
CO CV
_ O m O a N.
O N o M�
0 1� C7
0
0
HEATING COIL PEAK
CLG SPACE PEAK
COOLING COIL PEAK
0 l-
ap
c . mL
01
W a 3
oa co co
0 c I'-
mm Co
N
000000)CD N01000
0000 CO V OCO C. COO
O O 0OMCA0007 Nr
Oo00nv 0 CO0n cD
1 0 a- cv
CO CO
1� N CO
000 0
000 O
000 0
0 NO 0h 000000 0
ON ON000000 O
.0a-.00000000 0
N O
000 0 Ov0 0 000000 00 CO
r
0
N
•lb �C m- O 0OO r- NO COO r' Co 000 o 00000
=0 CO 0 m.3.. 10N a— CO CCD CD
O 0 0 r. N .10
00 c
0. 0.
CO CO
a
MI 0
0 o o n
0
O ▪ D S O c 1L E 0-
0. 0) CD o 0 o m -- o
To Y .Y 0 m c6 t6 co •C0 'p 6= j
>WcQKil C7saLLQ EW
(IJ
Internal Loads
CD
CC)
n
10
0.
m Y 0
m Wx a m
SS
A co _ c .5E=m R
j-G.111 0C 0Gc
�O'-IJ0Ox0m CO iro
m 0 C mmaQ o 13 0
L Ooo) a c� � ca 0. 200 �0. 13
Jam co maI >XQQQ'a%ca i
O>QOWOwstc0= ) C9
-- OOO�r�NO00v Cn0 NCO CO CO N 000 CD
1H
a00
O mL 000I101-.00000 N h0 C7 0) 00 0 0
o vvO) r` CD rnra) o
0 -. .... CO 0) 10 O N C0 CO CO r
Nm m CO a -a- N C; r- r- Co.
C
0
CO
O
O
0
0
O
0
O
N
C \ 000100000000)0 (0 Cp00 CO 007000000000 00
m
i 1- O
CO 0
co o. 0
• +- L 00 O 1010 C0000 a- CO CONC7 CD00000c0 o0000 N
O CD Z p 2 tO W W COO 0) N O tD O O W O)
naNO Fm Cpr N vc7r tti m
o mco E .. E OOOOOW O 0) CD00 0) 000 OOi 0o 0 m
= J CO CO CCOO CO 0)
o a+ m
Q aw
O m
tl)
mJ t 00000001�000. CO hCVC') N 000 0 0
0 0 3 v v 0) CO v O .•' CO v CO
10J CO0)00 COO 00 CD O N
67 ; 0.+ 0 O. N r 0.- CO ci
o
EQ
H� e a
f0 O c Y O
(5 mas
0'_'a 0 • O O it a I .ao co ac to
yjCO
��0. a0
a J�cO�N O00 LL 11 0 it a cON000o.c
o o c' o c0 c- O o c R coxxx.-N=
wC0C-)ocneo 0-2 J_ �'d m Q
Omm°rn'aUo 0W1-O mYn E° a)o Ea0au.
51t"2`
0 On T O ••• � W r p O= z m 0) m y C a Z� L d..t i+ a s
ccYi)cYn�c�C�3aLLa5cn Ja�cn om m>xamaca
W c O><0O11/141CC0 ,
Grand Total =_>
10
J°
ZWLL
0
0 o
W LE-
J —
Wa
U m
O a
Z°
W
vo
1n0
0 00
0 0 C.
Cn0 O 00
r- O O O O
to
00 O 00
0)
NO O 00 N
00 0 0o O
N N
x..0 w tp
x 0 =>
0 a ! = a 0
2Q a x0 I-
e
m
m
m '.
(7�
CD I..- CD
0
co 0
co O
co 0
V'0
1-0
M
CO CD
0
0
0
0
S 00 O
IYE 0D0 O
x m to
1-
0
CC
to P-
W
NC
O CIC
CI.
0
0
c
C6
m
0
111YORK RTv- /
SUBMITTAL DATA
Order #:
Project:
Project #:
Location:
Purchaser:
Submitter:
For: Quotation
Date: 10/22/2015
WILLIAMS MECH BUDGET NUMBER
RWS10222015-06
WASHINGTON
WILLIAMS MECH-BILL
YORK NW RYAN
IS•-- 0 !Lig
•
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 5 2015
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
OCT 2.2015
PERMIT CENTER
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 10/29/2015
Date
10/22/2015
Project Name
WILLIAMS MECH BUDGET NUMBER
Project Number
RWS10222015-06
Client! Purchaser
WILLIAMS MECH-BILL
111YORK
Submittal Summary Page
Qty Tag # Model # Description
1 ZFO36NO8A2AAA4 3 Ton, York Sunline Single Packaged R-410A Air Conditioner, 13.0
SEER / 11.0 EER, Single Stage Cooling, 79 MBH Output Aluminized
Steel, Single Stage Gas Heat, 1/2 HP Direct Drive Blower, 1"
Throwaway Filters, 208/230-3-60, Microchannel Condenser Coil,
Simplicity Lite Control, Galvanized Steel Drain Pan
1 RC0434 Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped
Knocked Down)
1 2EE04709224 Single Enthalpy Low Leak Jade Downflow or Horizontal Economizer
w/o Barometric Relief
1 RD0410 Barometric Relief Damper with Hood Kit (Downflow Unit or Duct
Mounted)
Equipment start-up and commissioning by a factory trained technician is recommended.
Contact your supplying distributor or sales representative for additional information & guidance.
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 10292015
YORI(
Small Sunline
Single Package R-410A Air Conditioner
Page: 3
Project Name: WILLIAMS MECH BUDGET NUMBER
Unit Model #: ZFO36NO8A2AAA4
Quantity: 1
System: ZFO36NO8A2AAA4
Cooling Performance
Total capacity 37.3 MBH
Sensible capacity 27.9 MBH
Refrigerant type R-410A
Seasonal Efficiency (at ARI) 13.00 SEER
Efficiency (at ARI) 11.00 EER
Ambient DB temp. 95.0 °F
Entering DB temp. 80.0 °F
Entering WB temp. 67.0 °F
Leaving DB temp. 60.4 °F
Leaving WB temp. 58.1 °F
Power input (w/o blower) 2.75 kW
Sound power 81 dB(A)
Gas Heating Performance
Entering DB temp. 60 °F
Heating output capacity (Max) 79 MBH
Supply air 1314.7 CFM
Heating input capacity (Max) 100 MBH
Leaving DB temp. 115.6 °F
Air temp. rise 55.6 °F
SSE 80.8 %
Stages 1
Supply Air Blower Performance
Supply air 1314.7 CFM
Ext. static pressure 0.64 IWG
Unit static resistance 0.09 IWG
Blower speed 925 RPM
Duct location Bottom
Motor rating 0.75 HP
Actual required BHP 0.42 HP
Power input 0.39 kW
Elevation 0 ft.
Drive type DIRECT
Speed tap 5
Electrical Data
Power supply 230-3-60
Unit min circuit ampacity 19.7 Amps
Unit max over -current protection 25 Amps
Dimensions & Weight
Hgt 33 in. Len 83 in. Wth 45 in.
Weight with factory installed options 533 lbs.
Clearances
Right 24 in. Front 32 in. Back 36 in.
Top 72 in. Bottom 0 in. Left 36 in.
Note: Please refer to the techguidefor listed maximum static pressures
us
n.�rt?.fc0
3 Ton
• York Units are Manufactured at an ISO 9001 Registered Facility and Each
Rooftop is Completely Computer -Run Tested Prior to Shipment.
Unit Features
• Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours
Salt Spray Test (ASTM B-117 Standards)
• Through -the -Curb and Through -The -Base Utility Connections
• Either Supply and/or Retum can be Field Converted from Vertical to
Horizontal Configuration without Cutting Panels.
• Full Perimeter Base Rails with Built in Rigging Capabilities
• Galvanized Steel Drain Pan
• Single Stage Cooling
• Solid Core Liquid Line Filter Driers
• Microchannel Condenser Coil
• 79 MBH Output Aluminized Steel, Single Stage Gas Nominal Heat
• 1/2 HP Direct Drive Blower
• Unit Ships with 1" Throwaway Filters with a Standard Filter Rack That Will
Accept up to 2" Filters
• Replacement Filters: 2 - (15" x 20" x 1" or 2") and 1 - (14" x 25" x 1" or 2").
Unit accepts 1" or 2" wide fitters.
• Single Point Power Connection
• Short Circuit Current: 5kA RMS Symmetrical
Standard Unit Controller: Simplicity Control Board
• An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag,
Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic
and Fault Code Display. Allows all units to operate in the cooling mode down
to 0 °F outdoor ambient without additional components or intervention.
• Safety Monitoring - Monitors the High and Low -Pressure Switches, the
Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch
on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition
Failures, Safety Lockouts and Repeated Limit Switch Trips.
Warranty
• One (1) Year Limited Warranty on the Complete Unit
• Five (5) Year Warranty - Compressors and Electric Heater Elements
• Ten (10) Year Warranty - Aluminized Steel Tubular Heat Exchangers
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 10/29/2015
YORK
Small Sunline
Single Package R-410A Air Conditioner
Page: 4
Project Name: WILLIAMS MECH BUDGET NUMBER Unit Model #: ZFO36NO8A2AAA4
Quantity: 1 System: ZFO36NO8A2AAA4
Factory Installed Options
ZFO36NO8A2AAA4
Product Category:
Product Identifier:
Nominal Cooling Capacity:
Heat Type and Nominal Heat Capacity:
Airflow:
Voltage:
Installation Options:
Additional Options:
Z
F
036
N08
A
2
A
AA
Product Generation:
1 RC0434 - Roof Curb - 14" High,
Flat, Uninsulated, Full Perimeter
(Shipped Knocked Down) (86.0
Ibs)
2EE04709224 - Single Enthalpy
Low Leak Jade Downflow or
Horizontal Economizer w/o
Barometric Relief (50.0 Ibs)
1 RD0410 - Barometric Relief
Damper with Hood Kit (Downflow
Unit or Duct Mounted) (6.0 Ibs)
4
York Sunline Single Packaged R-410A Air Conditioner
13.0 SEER / 11.0 EER
3Ton
Single Stage Cooling
79 MBH Output Aluminized Steel, Single Stage Gas
Heat
1/2 HP Direct Drive Blower
1" Throwaway Fitters
208/230-3-60
Microchannel Condenser Coil
Simplicity Lite Control
Galvanized Steel Drain Pan
Field Installed Accessories
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 10292015
Project Name: WILLIAMS MECH BUDGET NUMBER
ZE036NO8A1AAA4
T
c
W
3
C5
CL
Consolidated Drawing
4-
Z
an
0
mm,0
N 0
.O
N N
0
N
N.
aaD
N
COOm
CO
N
T
0 .O .O 0 00 01 .0
^a°J0^
00 CO
oct I, 013 CD Ws CO
N N N N N N N N N
CD
a
4-11
CO
N
N
CD
N4-1
N
00
CO N
^ 01
N N
CD
N
0
N
01
art
Ln
01
N
d
N
01
N
an
m
0
m
141
N
m
M u
m
co
1-4
frl
Cr,
IJI
m
W
u
01
N
CO
LO
N
CO
N
J
ON
to
N
an
ark
4-1
04
N
a
ara
N
Q
mtra
m
:O
fel
1-1
rra
m
4-1
1711
0
CO
m
e
rrl
e
V
4-1
m
4-1
.0
m
e
ro
w o1
01
u Q
an CD
N
N
•
CO 00
N N
V
N
0
1.0
•
0
N
Cr.
C
CD
CO
N
♦a1
N
01
LO
N
CO
CD
N
m
CD
N
00
LIN
0
CO
a
^
0
0
tO.1
^
V
00
m
N
0
m
u
N
X
CO
an
0
0
co
an
art
r^+1
•
co
m
m
v
0
CO CO
0 01
m
O1 a�
1^+1
.0
m
a
4-4
0
4-1
0
a
CO
m
1n
m
eV
00
i0
O
m
01
0
01
01
0
rn
01
N
N
0.1
m 01 0
m
041
40
N
u
00
Q
4-1
.--.
00 CO
u
40
CO
CO
an
10
O1
u
co
u
CD
an
an
GO
OD
u
Cis
LLI
r
COOLING ONLY UNITS.
LI-
N
1
v
N
Lrt
N
.0
CC
rn
CC
v
00 0
pp In
N�
co
a
0-
X
v
m Cr:.acr
Q n u
DJ
CO
w . 0�' 111
tX r.n 1
Qi 1i.-. of va mm 01 0Opp2
�.--.! O cc 2 ¢ Q C .,On..O 0- ce N Y W z
ac cc a -a cc z¢ Q6N 2 m Q
wO au pa.- 0 ON
N N. N N J 0 W 0 d0 H 01 g
22 J 22au Vl7 S v1OK= Q cOW
z z Da ...-.2 z•-• 0.1 Qrz1 a O`OD- v 0 HO.-
00 �1--Ooc 2crw14.1u' - au 00 -
wV2.¢..w1aVi0 OwQ 2 Q .Oi104 w2 12-1w0 F
VI20v1 ann22 1--z Onw 2M yQz 0
X20-10V= -A2 -Eww
J3 VO 0 JH¢ W VV O1 ^
3H O.n0Q01 V SH d
12-1
Q O20HO2m ¢F-12-10w . 2
m 0 OOr wO O>c Q Q 2
a02H wH2 Qr 1-w0 o3 Ca_
42/-221_w wS arl K pp
J Ca LLm ON ON act mNGtGt m ¢t,� z¢ z ¢ w=
CD Oe'1 CO N0N VH I- Ca Q 0Ow 0 .n
2 O0001001 en O1 N V W u¢p OH>�C
• w
OWr }1J1-1
2 021-H ¢2 0
dO r.nw QF- 00 0,
W QWcf.00V NN.0 NOKd - 000O art Q.-�.0I-O 0-
NNrt1N1nNr/1 i� QV1}0 2O2..V'
020 VI rJw +Q 2J32 X
32 •- 20 2 OO Jl0O 2 HH.n�
c OQw-- WOOO2w al_ 1--2 O ^a
O SX0w OD V Vpr NV/-J
Ov1WH0 J} 2Q1-O V WZ Z ,0 viH -- 360c VO 0J0H
-an-0 -- FQ.-O0000 2 23 1-4¢2�
21-0 r 1- -• 02 V JV 0 022 o 022. 2
OS SF 2 - - . 0 Q11_ W1n O2JWNOw
10-1 -171r- O W F- r2.�c V1 wr0 VJ
ZHw CC
0CI. 23O OOF-2WErV11- V
O WHCJ c Hm 000 Co 0 d'Hp1-12 H0_HX
3E V 0C H V 040 Fr 0000
--a0 00001000
N 1+1
z
01 CZ C001
DIRECTION OF AIRFLOW
CENTER OF GRAVITY
cCO
Q
•
m N
•
N
CO°..
CO m
cr.
cc, N cGO
m
act,N-1
•
\ f iN_.
,
NC CD
i
mT
-13
cn
01w
N
cc co
r"n 01
N u
Printed 10/22/2015
ect to change without notice. Check local codes.
Information is su
Unitary Sales Tool v1.5.9.0
i�YORK
Small Sunline
Single Package R-410A Air Conditioner
Page: 6
Project Name: WILLIAMS MECH BUDGET NUMBER Unit Model #: ZFO36NO8A2AAA4 1
v o
1 I r
I r 1 I I I 1
r 1 r
I
!
FIELD -SUPPLIED
DISCONNECT SWITCH
TO
POWER
SUPPLY
T CONDENSATE
TRAP
CONTROL WIRING
TO INDOOR
THERMOSTAT
ROOF JACK
INSTALLATION
1 i 1
I1 1
RETURN AIR
DUCT
1 i
SUPPLY MR
DUCT
r�
ROOF CURB
INSTALLATION
SLAB ON GROUND
INSTALLATION
ta 11 QI
a S i
I I
ROOF CURB
•
MANUAL
GAS SHUT-OFF
VALVE
TO GAS SUPPLY LINE
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 10292015
IYORK
Small Sunline
Single Package R-410A Air Conditioner
Page: 7
Project Name: WILLIAMS MECH BUDGET NUMBER Unit Model #: ZFO36NO8A2AAA4
CONTACTOR
'
sY Imo
1
r I
GR
ND
LUG
TYPICAL POWER WI=EIPC
FIELD -SUPPLIED
DISCONNECT '
r-- , SINGLE
- r > PHASE
-O- L.O- POWER
CONTACTOR
1
L j SUPPLY
GROUND L
REFER TO THE ELECTRICAL DATA
TABLES TO SIZE THE DISCONNECT
SWITCH, OVER CURRENT
PROTECTION AND WIRING.
LUG
I
L
L
,,zrcTnm' i►q.awnuxg gpasi
FIELD -SUPPLIED
DISCONNECT
r 1
-p. 1 _r_ THREE
-t- - - -> PHASE
$' 0--L 3 POWER
L J SUPPLY
TYPICAL COOL/HEAT CONTROL WIRING
COOLING ONLY (24 VOLT THERMOSTAT)
THERMOSTAT' UNIT TERMINAL
TERMINALS STRIP TB1
24 VOLT
TRANSFORMER
124 VOLT THERMOSTAT. TO CONTROL THE ECONOMIZER ON SECOND
STAGE COOLING. USE A 2 STAGE COOLING THERMOSTAT.
COOLING / HEATING (ELECTRONIC THERMOSTAT)
MULTI STAGE
THERMOSTATI
TERMINALS
ADD
JUMPER
ADD
JUMPER
NOT
D 4
UNIT TERMINAL
STRIP TB1
2—
TO REMOTE SENSOR
IF USED
24 VOLT
TRANSFORMER
ELECTRONIC PROGRAMMABLE THERMOSTAT TYPICAL.
SECOND STAGE COOLING IS NOT REQUIRED ON UNITS LESS ECONOMIZER.
1 SECOND STAGE HEATING IS ONLY REQUIRED ON UNrrS WITH A TWO STAGE
ELECTRC HEATER OR 2 STAGE GAS HEAT.
. REMOVE JUMPER J2 FROM TERMINALS 4 AND 9 ON JUMPER PLUG CONNECTOR
P6 ON UNITS WITH ECONOMIZER. TERMINALS Al AND A2 PROVIDE ARELAY
OUT -PUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE
THERMOSTAT SWITCHES TO THE SET -BACK POSITION.
COOLING / HEATING (24 VOLT THERMOSTAT)
THERMOSTATI
TERMINALS
UNIT TERM NAL
STRIP TB1
ADD
JUMPER
24 VOLT
TRANSFORMER
'24 VOLT THERMOSTAT. TO CONTROL THE ECONOMIZER ON THE SECOND
STAGE COOUNG OR TO HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO
STAGES OF HEAT, USE A 2 STAGE COOL AND HEAT THERMOSTAT.
COOLING / HEATING (ELECTRONIC THERMOSTAT)
SINGLE STAGE
THERMOSTAT'
TERMINALS
UNIT TERMINAL
24 VOLT
TRANSFORMER
1ELECTRONIC PROGRAMMABLE THERMOSTAT TYPICAL. TO CONTROL THE
ECONOMIZER ON SECOND STAGE COOLING. USE A 2 STAGE COOL AND
HEAT THERMOSTAT.
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes. Printed 10/29/2015
�YORIC
Small Sunline
Single Package R-410A Air Conditioner
Page: 8
Project Name: WILLIAMS MECH BUDGET NUMBER Unit Model #: ZE036NO8A1AAA4
Quantity: 1
System: ZE036NO8A1AAA4
BACK
OF UNIT
SUPPLY'
AIR
RETURN'
AIR
37-114"
DUCT SIZES:
Supply Air = 19" x 19"
Retum Air = 19" x 19"
1RC0434 Roof Curb
2" TYP_
DUCT SUPPORT
RAILS
iRC0434 Roof Curb Dimensions
73"
COMPRESSOR
AND CONDENSER
END OF UNIT
FRONT
OF UNIT
Supply and Retum Air (including duct support rails)
shown are typical for bottom duct applications.
For location of horizontal duct applications
(on back of unit). refer to Unit Dimensions details.
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 10/222015
Date
10/22/2015
Project Name
WILLIAMS MECH BUDGET NUMBER
Project Number
RWS10222015-06
Client / Purchaser
WILLIAMS MECH-BILL
LIYORK
Guide Specification Summary Page
Product Series Models and Unit Tags
!Small Sunline ZE036NO8AIAAA4
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes. Printed 10222015
YORK
Guide Specification for
York Sunline
Page: 10
GENERAL
Units shall be manufactured by Johnson Controls Unitary
Products in an ISO 9001 certified facility. York Sunline
units are convertible single package units. Although the
units are primarily designed for curb mounting on a roof,
they can also be slab -mounted at ground level or set on
steel beams above a finished roof. Cooling only, cooling
with gas heat and cooling with electric heat models are
available with a wide variety of factory -mounted options
and field -installed accessories to make them suitable for
almost every application. All units are self-contained and
assembled on full perimeter base rails with holes in the
four comers for overhead rigging. Every unit is
completely piped, wired, charged and tested at the
factory to simplify the field installation and to provide
years of dependable operation. All models (including
those with an economizer) are suitable for either bottom
or horizontal duct connections. Models with power
exhaust are suitable for bottom duct connections only.
For bottom duct, remove the sheet metal panels from the
supply and retum air openings through the base of the
unit. For horizontal duct, remove the supply and return
air panels on the rear of the unit.
All non -Scroll compressors include crankcase heaters and
all compressors have intemal pressure relief. Every
refrigerant circuit includes a liquid line filter -drier, a
discharge line high pressure switch and a suction line with
a freezestat and low pressure/loss of charge switch. The
unit control circuit includes a 75 VA transformer, a 24-volt
circuit breaker and a relay board with a compressor
lockout circuit, a terminal strip for thermostat wiring, plus
an additional set of pin connectors to simplify the interface
of additional field controls. All models are CSA listed. All
models include a 1-year limited warranty on the complete
unit. Compressors and electric heater elements carry a 5-
year warranty. Aluminized steel and Stainless steel tubular
heat exchangers carry a 10-year warranty.
DESCRIPTION
Units shall be factory -assembled, single packaged,
Electric Cooling/Gas Heat, Electric Cooling/Optional
Electric Heat, Heat Pump/Optional Electric Heat are
designed for outdoor mounted installation.
The 3 ton, 4 ton and 5 ton units shall have minimum SEER
rating of 13.0 with heat pumps having a 7.7 H.S.P.F. The 6
Ton Cooling only or Cooling with Electric Heat shall have
11.2 EER, 6 Ton Cooling with Gas Heat shall have 11.0
EER. They shall have built-in field convertible duct
connections for down discharge supply/retum or horizontal
discharge supply/retum, and be available with factory
installed options or field installed accessories. The units
shall be factory wired, piped, charged with R-410A
refrigerant and factory tested prior to shipment. All unit
wiring shall be both numbered and color coded. All units
the cooling performance shall be rated in accordance with
DOE and AHRI test procedures. Units shall be CSA listed,
classified to ANSI Z21.47, UL 1995/CSA No. 236
standards.
UNIT CABINET
Unit cabinet shall be constructed of galvanized steel, with
exterior surfaces coated with a non -chalking, powdered
paint finish, certified at 1000 hours salt spray test per
ASTMB117 standards. Indoor blower section shall be
insulated with a minimum 1/2" thick insulation, coated on
the airside. Aluminum foil faced insulation shall be used in
the fumace compartment and be fastened with ridged
fasteners to prevent insulation from entering the air
stream. Cabinet panels shall be "large" size, easily
removable for servicing and maintenance. Full perimeter
base rails shall be provided to assure reliable transit of
equipment, overhead rigging and proper sealing on roof
curb applications. Disposable 1" filters shall be fumished
and be accessible through a removable access door,
sealed airtight. Units filter track shall be designed to
accommodate either 1" or 2" fitters. Fan performance
measuring ports shall be provided on the outside of the
cabinet to allow accurate air measurements of evaporator
fan performance without removing panels or creating air
by-pass of the coils. Condensate pan shall be intemally
sloped and conform to ASHRAE 62-89 self -draining
standards. Condensate connection shall be a minimum of
3/4" I.D. female and be a ridged mount connection.
INDOOR (EVAPORATOR) FAN ASSEMBLY
The indoor fan shall be a factory installed direct -drive or
belt -drive assembly that includes an adjustable pitch motor
pulley. Job site selected (B.H.P.) brake horsepower shall
not exceed the motors nameplate horsepower rating, plus
the service factor. Units shall be designed not to operate
above service factor. Fan wheel shall be double -inlet type
with forward -curved blades, dynamically balanced to
operate smoothly throughout the entire range of operation.
Airflow design shall be constant air volume. Bearings shall
be sealed and permanently lubricated for longer life and
no maintenance.
OUTDOOR (CONDENSER) FAN ASSEMBLY
The outdoor fan shall be of the direct -driven propeller type,
discharge air vertically, have aluminum blades riveted to a
corrosion resistant steel spider bracket and shall be
dynamically balanced for smooth operation. The outdoor
fan motor shall be totally enclosed with permanently
lubricated bearings, intemally protected against overload
conditions and staged independently.
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 1022/2015
YORI(
Guide Specification for
York Sunline
Page: 11
REFRIGERANT COMPONENTS
Compressors:
a. Shall be intemally protected with intemal high-
pressure relief and over temperature protection.
b. Shall have intemal spring isolation and sound
muffling to minimize vibration and noise, and be
extemally isolated on a dedicated, independent
mounting.
Coils:
a. Evaporator coils shall have aluminum plate fins
mechanically bonded to seamless intemally
enhanced copper tubes with all joints brazed. Special
Phenolic coating shall be available as a factory
option.
b. Evaporator coils shall be of the direct expansion,
draw thru design.
c. Condenser coils shall have aluminum plate fins
mechanically bonded to seamless intemally
enhanced copper tubes with all joints brazed or
Micro -Channel aluminum tube, aluminum fins.
d. Condenser coils shall be of the direct expansion,
draw thru design.
Refrigerant Circuit and Refrigerant Safety Components
shall include:
a. Independent fixed -orifice or thermally operated
expansion devices.
b. Filter drier/strainer to eliminate any moisture or
foreign matter.
c. Accessible service gage connections on both suction
and liquid lines to charge, evacuate, and measure
refrigerant pressure during any necessary servicing
or troubleshooting, without losing charge.
d. The refrigeration system shall provide at least 15°F of
sub -cooling at design conditions.
Unit Controls:
a. Unit shall be complete with self-contained low -voltage
control circuit protected by a resettable circuit breaker
on the 24-volt transformer side.
b. Unit shall incorporate a lockout circuit which provides
reset capability at the space thermostat or base unit,
should any of the following standard safety devices
trip and shut off compressor.
c. Loss-of-charge/Low-pressure switch.
d. High-pressure switch.
e. Freeze -protection thermostat, evaporator coil.
f. Unit shall incorporate "AUTO RESET" compressor
over temperature, over current protection.
g-
Unit shall operate with conventional thermostat
designs and have a low voltage terminal strip for
easy hook-up.
h. Unit control board shall have on -board diagnostics
and fault code display.
i. Standard controls shall include anti -short cycle and
low voltage protection, and permit cooling operation
downto0°F.
Control board shall monitor each refrigerant safety
switch independently.
k. Control board shall retain last 5 fault codes in non
volatile memory which will not be lost in the event of a
power loss.
GAS HEATING SECTION (SINGLE STAGE)
Shall be designed with induced draft combustion with
post purge logic, energy saving direct spark ignition, and
redundant main gas valve. Venter wheel shall be
constructed of stainless steel for corrosion resistance.
The heat exchanger shall be of the tubular type,
constructed of T1-40 aluminized steel for corrosion
resistance and allowing minimum mixed air entering
temperature of 25°F. Burners shall be of the inshot type,
constructed of aluminum coated steel and contain air
mixture adjustments. All gas piping shall enter the unit
cabinet at a single location through either the side or
curb without any field modifications. Integrated control
boards shall provide timed control of evaporator fan
functioning and bumer ignition. Heating section shall be
provided with the following minimum protection.
a.
b.
c.
d.
e.
Primary and auxiliary high -temperature limit switches.
Induced draft motor speed sensor.
Flame roll out switch.
Flame proving controls.
If any of the above safety devices trip, a LED (light -
emitting diode) indicator shall flash a diagnostic code
that indicates which safety switch has tripped.
NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage,
40% Capacity 2nd Stage.
UNIT OPERATING CHARACTERISTICS
Unit shall be capable of starting and running at 125°F
outdoor temperature, exceeding maximum load criteria
of AHRI Standard 210/240. The compressor, with
standard controls, shall be capable of operation down to
0°F outdoor temperature. Unit shall be provided with fan
time delay to prevent cold air delivery before heat
exchanger warms up (Gas heat only).
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 10/22/2015
YORK
Guide Specification for
York Sunline
Page: 12
ELECTRICAL REQUIREMENTS
All unit power wiring shall enter unit cabinet at a single
factory provided location and be capable of side or
bottom entry, to minimize roof penetrations and avoid
unit field modifications. Separate side and bottom
openings shall be provided for the control wiring.
STANDARD LIMITED WARRANTIES
• Compressor 5 Years
• Heat Exchanger 10 Years
• Electric Heat Element 5 Years
• Other Parts 1 Year
ADDITIONAL FACTORY INSTALLED OPTIONS
FIELD INSTALLED OPTIONS
• Roof Curb — 14" high, full perimeter curb with wood
nailer (shipped knocked -down).
• Barometric Relief Damper — This damper accessory
can be used to relieve intemal building air pressure
on units with an economizer without power exhaust.
This accessory includes a rain hood, a bird screen
and a fully assembled damper. With bottom duct
connections, the damper should be mounted over the
opening in the retum air panel. With horizontal
ductwork, the accessory should be mounted on the
return air duct.
Unitary Sales Tool v1.5.9.0
Information is subject to change without notice. Check local codes.
Printed 10222015
City of Tukwila
Department of Community Development
November 13, 2015
BILL ALSEPT
3903 SMITH AVE
EVERETT, WA 98201
RE: Correction Letter # 1
MECHANICAL Permit Application Number M15-0144
POP GOURMET POPCORN - 14550 INTERURBAN AVE S #100
Dear BILL ALSEPT,
Jim Haggerton, Mayor
Jack Pace, Director
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these
comments.
• (GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised
plan sheets shall be the same size sheets as those previously submitted.)
(If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of
the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature.
Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp,
signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a
bound specification document that contains specifications other than that of an engineering or land surveying
nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is
responsible." It shall not be required to have each page of "specifications" to be stamped and signed. [Electronic
copies shall not be approved.] (WAC 196-23-010 & 196-23-020)
(BUILDING REVIEW NOTES)
1. Show where roof access is located. If access is over 16 feet from the finish grade a roof access ladder shall be
provided. If located within 10 feet of the roofs edge, a guard shall be provided, see item #2. (IMC 306.5)
2. The new RTU is shown to be within eight feet of the buildings edge. Guards shall be provided where appliances,
equipment, fans, roof hatch opening or other components that require service are located within 10- feet of a roof
edge or open side of a walking surface and such edge or open side is located more than 30-inches above the floor,
roof or grade below. The guard shall be constructed so as to prevent the passage of a 21-inch-diameter sphere. The
guard shall extend not less than 30-inches beyond each end of such appliances, equipment, fan or component. Show
a guard with details or relocate the mechanical unit. (2012 IMC 304.112012 IBC 1013.6 & 1013.7)
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
If you have any questions, I can be reached at (206) 433-7165.
Sincerely,
Rachelle Ripley
Permit Technician
File No. M15-0144
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M15-0144 DATE: 11/17/15
PROJECT NAME: POP GOURMET POPCORN
SITE ADDRESS: 14550 INTERURBAN AVE S - SUITE 100
Original Plan Submittal
X Response to Correction Letter # 1
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
MK/ "
Building Division
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator 11
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
DATE: 11/19/15
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
(corrections entered in Reviews)
Approved with Conditions
Denied
(ie: Zoning Issues)
DUE DATE: 12/17/15
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M15-0144 DATE: 10/29/15
PROJECT NAME: POP GOURMET POPCORN
SITE ADDRESS: 14550 INTERURBAN AVE S - SUITE 100
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
OOP- (0-(I t
Building Division
Public Works
Ijk
Fire Prevention
Structural
Planning Division
Permit Coordinator III
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 11/0315
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
Approved with Conditions
Denied
(corrections entered in Reviews) (ie: Zoning Issues)
DUE DATE: 12/01/15
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.TukwilaWA.gov
REVISION
SUBMITTAL
Revision submittals must be submitted in person at the Permit Center.
Revisions will not be accepted through the mail, fax, etc.
Date: )/ /
Plan Check/Permit Number:
❑ Response to Incomplete Letter #
Response to Correction Letter # l
Pi
M)5 -01
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: POf 6Oo%, g% jg/CokV
Project Address: % 11 5 l 6 %/VTMOXi3/lj/ ri) Ui S /Ov
Contact Person: g JL. A� 7L.S / Phone Number: '2 5 7 S9 S 7
Summary of Revision:
(O/6A qi0.-/ TO 3H E7 e_ 6 .5 Nvw/A/ - 7/1Z
CoAg G; /ow 70 341FI-T /7 - ?f bt-»JN -
l /ipr- —WE l S EA/o v 6/4 L-r/1A9,�CU'
7/IL= % (/ /9,v„9
CITY OF TUKWILA
fat /7 MS
PERMIT t:RlTER
Sheet Number(s): /14 7 %�,V/� H 6
"Cloud" or highlight all areas of revision including date of revis
Received at the City of Tukwila Permit Center by: T
�-- Entered in TRAKiT on I 1---( (�
WILLIAMS MECHANICAL INC
Hone lnicio en .Espafiol Contact
Page 1 of 2
A-7,, Index Help biy Secure.1. &I.
Safety Claims & Insurance Workplace Rights Trades & Licensing
0 Washington State Department of
Labor & Industries
WILLIAMS MECHANICAL INC
Owner or tradesperson
Principals
WILLIAMS, BRADLEY PATRICK, PRESIDENT
WILLIAMS, DEBORAH KAY, SECRETARY
WILLIAMS, DEBORAH KAY, TREASURER
WILLIAMS, DEBORAH KAY, AGENT
ZUCCARINI, MICHAEL J, AGENT
(End: 01/01/1980)
Doing business as
WILLIAMS MECHANICAL INC
WA UBI No.
601 413 863
3903 SMITH AVE
EVERETT, WA98201-4549
425-303-0828
SNOHOMISH County
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor
License specialties
GENERAL
License no.
WILLIMI088PA
Effective — expiration
10/01/1992-10/01/2017
Bond
Merchants Bonding Co (Mutual)
Bond account no.
WA33987
Active.
Meets current requirements.
$12,000.00
Received by L&I Effective date
09/23/2014 10/01/2014
Expiration date
Until Canceled
Bond history
Insurance
....................
Allied Property & Cas Ins Co $1,000,000.00
Policy no.
ACP3007325217
Received by L&I Effective date
10/13/2015 09/30/2015
Expiration date
09/30/2016
Insurance history
Savings
...................
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601413 863 &LIC=WILLIMI088PA&SAW= 12/4/2015
•1•1001.
.01111111.
F007 TALL ItvAlLi
*10"
Rio-! mono
movE0
er
1
NEW HVAC UNIT
PLACE OPENING PER
EXISTING STRUCTURAL
JOISTS
v
MECH UNIT BODY
DAMPENING MATERIAL PER MANUF.
FACTORY NAILER STRIP (2X)
GALV. MTh FLASHING — TYP.
ATTACH TO CURB AS REM) BY MANUF.
GALV. MIL COUNTER FLASHING — TYP.
FACTORY CURB ATTACH PER MANUFACTURER
ROOFING MEMBRANE UP & OVER .CURB
ATTACH ROOF'G TO NAILER AT TOP OF CURB
18" OC, MIN 2 PLACES EA. SIDE
SEE STR(JCT. FOR TYP. OPENING•
SUPPORT AND ROOF PENETRATIONS
ROOF STRUCTURE
ROOF BLOCKING
MECH. CURB DETAIL
1"4-0"
•
No changes shall be made tr)
of work t^fithout prior 9. 1 ri
Building UV :3•.'"!",
roquire r -,17:':7:1 • •
LIcnionalr,
FILE C'71
Permit No.
• Plan review approval i ii
Approval of construction
the violation of any ador- .
of approved Fie:
0.0.1.1111••••••••
SEPARATE PERMIT
mcnan:cc,
)2r Electrical
)21 Piurnbing .
p Gas Piping
Ci:j of Tuki.v!la
BlYt.ri D'AffSfON
411•11.M.
and omissions. •
• riot authorize
TAinance. Receipt
is acknowledged:
REVIEWED FOR
CODE COMPLIANCE
APP OVED
NOV 2 5 2015
frd 1212-
City of Tukwila
BUILDING DIVISION
REMARKS
TI PER IT SUB ITTAL
)
1
r.
k
ui
0
- \,
tr
Zi
\
\)
uJ
REGISTERED
• ARCH CT
WILUAM 'FULLER
STATE OF WASHINGTON
six
ta
RECEIVED
CITY OF TUKWIL4
•NOV 1 7 26;5
PERMIT CENTER
Williams Mechanical
3903 Smith Ave
Everett, WA 98201
M-4
e`•
1" Gas line
Connect to existing tap
1•011.10
410111111
1111111•••
18x12
18x12 up to RTU-1
Supply and return
Insulate per code
./ • •,• • • 3 ..•
0000000 .• • •
STAIRS TO STORAGE AB
rr
I 1
HI
(WAREHOUSE\
\RESTROOM/
/
2x2 Iayin return
600 CFM 12"
4" vent up to roof
( RESTRO • Yi
Ceiling fans
by other
2x2 Iayin return
300 CFM 10"
Typ of 2
LEVEL 1 FLOOR PLAN
3/16" = 1'-0"
• TOP OF PAINTED
GUARDRAIL
TOP OF PAINTE
HANDRAIL
. 4
NOSING
STAIR SECTION
1/2- =
STAIR FRAMING PER
STRUCTURAL
CLOSED RISER
• . .
DEMISING WALL
TOP OF PAINTED
GUARDRAIL:
1-Y2" x 1-h" x
HSS
1 4/2" 0 PAINTED HANDRAIL
ENDS OF HANDRAIL TO
TURN DOWN
: ' •
•
3'-2'
x x HSS
PAINTED STANCHIONS
3'-8"
3". 0 PAINTED ROD WELDED
TO STANCHIONS
BOLTED CONNECTION TO
STRINGER PER STRUCTURAL
CENTER PLATE ON STAIR TREAD
CLEAR DIMENSION BETWEEN RODS
TO BE LESS THAN 4", TYP.
STAIR ELEVATIO
1/2" =
1 1/2" DIA. MIL
GUARDRAIL
T.O. PAkAPET 101-0"
• 3/4" PLYWkOD "DECKIG"
0/ FRAMING PER 'ERUCT.
GUARD RAIL
EQ. SPACED VERT. 1 1/2"0
GALV. PIPE POSTS
(7) EQ. SPACED 1"0
GALV PIPE RAILS
••••••..
ATTACHED GUARDRAIL TO
MEZZANINE TOP SILL
PLATE PER STRUCTURAL
DRAWING
ALL PIPE RAIL'GS JOINTS TO BE WELDED
ALL AROUND AND GROUND SMOOTH PRIOR
TO HOT DIP GALVANIZING TYP.
GUARDRAIL @ MEZZ.
1 /2" =-- 1'-0"
13'-9"
SLOPING 42" HIGH WALL
ABOVE STAIR TREAD
MEZZANINE PLAN
(941 SF)
EL. +14'-0"
MEZZANINE PLAN
1 /4"=r-0"
•
REVIEWED FOR
CODE COMPLIANCE
APPROVED
111111.11111•••••1•SI
NOV 2 5 2015
City of Tukwila
BUILDING DIVISION
• RECEIVED
CITY OF TUKWILA
OCT 2.a 2015
PERMIT CENTER
IF THIS DRAWING IS NOT 24" X 36" IT IS A REDUCED PRINT.
•
Existing tap with
valve
NS\
wPEER L-
•
✓ srrrrrrsrrrrrrrr rrrrrrrrrrrrrrrr rrrrrrrrrrrrrrrrrrr rrrrrrrrrrrrir
■ r—, . r--1 r—`1 r—n r--1
I I ■ I• 1 I I • 1 .1 I I
I I 0 I I I I I I I I
•
■ �a
d Point of connection 1" gas line 21b
• 3/4" gas line to office Existing
•
Existing Unit Heater •° -
75,000 BTU •
•
• I DEMISING WALL
e TENANT
A00
L i
1 r--1 r—n ri
r—n r—n ri
I I 1 1 I I 1 1 I I 1 I I I 1 I I I 1 I I I I I I ^
I I 1 I • II• I I 1 1 . 1 1
L—J L—J ■ L.—J L—J L—J L—J
II
■
■ •
All gas line below roof ■
•
new and existing s
■
o 1 1 1_ 1
s
• 1 1 1 1
• 1 1
1 I
• L.-J L—J
II
■ II �—
r--I r--1
I I 1 I
II II
I 1 I' I
L— J L — J
1111111 " m
3/4" gas line up to
RTU-1 on roof
100,000 BTU
L
1
1
1
1
•
-
Gas line from existingtapto RTU-1
POP GOURMET suite A-iOO
-000
Existing 2Ib Gas meter space A-100
AL-425 MAOP 10 PSI
ANSI Class 400
14Y755448
000
Separate meters
for other suites.
0
FOR FLOOR STRUCTURE,
REFER TO APPROVED
STRUCTURAL DRAWING
DATED 19/09/2014
UNDER PERMIT NUMBER
D11-060
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 5 2015
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
NOV 17 2015
REMARKS
T.I. PERMIT SUBMITTAL I
¢
co
o-
0----
I
orb
z
16/7
gl=
toon
■
DC
W
Lam
REGISTERED
ARCHITECT
WIW ' • UR FULLER
STATE OF WASHINGTON
Job Numbs:
1005 0.032
Date
MAY 15, 2015
�r►c�al n a10
Propet Mor :
'UAW FULLER
VAHID KHASTOU
Gas Line
AIRCHITICTs