Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M15-0145 - KING COUNTY LIBRARY SYSTEM - HVAC SYSTEM
KING COUNTY LIBRARY 14380 TUKWILA INT'L BLVD M15-0145 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 1523049092 14380 TUKWILA INTERNATIONAL BLVD KING COUNTY LIBRARY SYSTEM Permit Number: M15-0145 Issue Date: 11/23/2015 Permit Expires On: 5/21/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA CITY OF 6200 SOUTHCENTER BLVD , TUKWILA, WA, 98188 BENJAMIN GOZART 600 UNIVERSITY ST, STE 500 , SEATTLE, WA, 98101 Phone: (206) 342-9900 P S F MECHANICAL INC Phone: (206) 764-9663 11621 E MARGINAL WAY S SUITE A , TUKWILA, WA, 98168-1965 PSFMEI*090NZ Expiration Date: 10/5/2017 I II DESCRIPTION OF WORK: NEW HVAC SYSTEM FOR NEW LIBRARY. 100% OUTDOOR AIR SYSTEM FOR VENTILATION WITH HEAT RECOVERY. RADIANT FLOOR HEAT/COOL FROM WATER SOURCE HEAT PUMP WITH GEOTHERMAL EXCHANGE. AIR SOURCE HEAT PUMP FOR FULL OAD HEAT/COOL BACKUP WITH ADDITIONAL PAN COIL FOR FAST REACTION HEAT/COOL NEEDS. Valuation of Work: $446,000.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $4,942.74 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: Date:jfr'wi C I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development p rmit and agree to`he conditions attached to this permit. Signature: / J Print Name: Date: (1 P3// This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 2: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 3: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 4: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 5: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 6: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 7: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 8: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 9: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 14: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 15: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 16: Readily accessible access to roof mounted equipment is required. 17: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 18: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 19: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 20: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 21: ***MECHANICAL PERMIT CONDITIONS*** 22: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 23: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://vvww.TukwilaWA.gov Mechanical Permit No. Mis- 014 Project No. Date Application Accepted: Date Application Expires: 3;1?-0 or o i ce use on MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION ;�'' King Co Assessor's Tax No.: Site Address: 1445Tukwila International Blvd. Suite Number: Floor: Tenant Name: King County Library System PROPERTY OWNER Name: Greg Smith Address: 10 W Sunset Way City: Issaquah State: WA Zip: 98027 CONTACT PERSON — person receiving all project communication Name: Benjamin Gozart - WSP Address: 600 University Street, Suite 500 City: Seattle State: WA Zip: 98101 Phone: (206) 342-9900 Fax: Email: benjamin.gozart@wspgroup.com New Tenant: 0 Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: ps F k\ ,'GI1,,i %G„ Address: ! 6 2 1 R- , Wt a ✓'cl , lt,,,., ( fact City: Se`,�.f—%,e State:' j Zip•751 !_ 1741_ Phone: Z0 /' 1 4 / b6 3 Fax: Contr Reg No.: t S F pl C ] -' 1 orrt,xp Date: 10 `' 126 i Tukwila Business License No.: A 1...,c 1 a Q I on. GI Valuation of project (contractor's bid price): $ 446,000 Describe the scope of work in detail: New HVAC system for new library. 100% Outdoor Air System for ventilation with heat recovery. Radiant floor heating/cooling from water source heat pump with geo-thermal exchange. Air -source heat pump for full load heating/cooling back-up with additional VRF fan coils for fast reaction to space heating/cooling needs. Use: Residential: New ❑ Replacement ❑ Commercial: New 0 Replacement ❑ Fuel Type: Electric..... Gas ❑ Other: H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised lt-9-11.doex Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 0 Furnace >100k btu 0 Floor furnace 0 Suspended/wall/floor mounted heater 0 Appliance vent 0 Repair or addition to heat/refrig/cooling system 0 Air handling unit <10,000 cfin 1 Unit Type Qty Air handling unit >10,000 cfin O Evaporator cooler 0 Ventilation fan connected to single duct 1 Ventilation system 1 Hood and duct 0 Incinerator —domestic 0 Incinerator — comm/industrial O Unit Type Qty Fire damper 1 Diffuser 35 Thermostat 7 Wood/gas stove 0 Emergency generator 0 Other mechanical equipment o Boiler/Compressor Qty 0-3 hp/100,000 btu 0 3-15 hp/500,000 btu 2 15-30 hp/1,000,000 btu 0 30-50 hp/1,750,000 btu 0 50+ hp/1,750,000 btu 0 PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN OWNER OR A HORI`ZED AGENT: Signature: / Date: u T / Y / / 5 Print Name: (-1 . eo, �\ Day Telephone: qls—� / ( - t�Zf� MailingAddress: (6 '' Mnl t 44vvi le Jti`e/td I L Ytb.liw 1 ` e WA- is-IT-2_ ( �� City State Zip H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 11-9-I I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT PermitTRAK I QUANTITY I PAID $3,992.21 M15-0145 Address: 14380 TUKWILA INTERNATIONAL BLVD Apn: 1523049092 $3,992.21 MECHANICAL $3,802.10 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $3,769.60 TECHNOLOGY FEE $190.11 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6708 R000.322.900.04.00 0.00 $190.11 $3,992.21 Date Paid: Monday, November 23, 2015 Paid By: KING COUNTY LIBRARY SYSTEM Pay Method: CHECK 3020755 Printed: Monday, November 23, 2015 8:14 AM 1 of 1 CPWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $950.53 M15-0145 Address: 14380 TUKWILA INTERNATIONAL BLVD Apn: 1523049092 $950.53 MECHANICAL $950.53 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R6564 R000.322.102.00.00 0.00 $950.53 $950.53 Date Paid: Tuesday, November 03, 2015 Paid By: KING COUNTY KLBRARY SYSTEM Pay Method: CHECK 3020737 Printed: Tuesday, November 03, 2015 7:37 AM 1 of 1 CrL1 LS SYSTEMS INSPECTION RECORD Retain a copy with permit /11 i5-o1g5 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: k'H& CDURITY /-J6RARY Type of Inspection: e/ '& L A7P1M- Address: /0i , B. Date Called: Special Instructions: 3k — AS REMer— Date Wanted: ii !r Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: Date: y-, 7-, 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: KK tit1PAi / Type of Inspection: � i iecihoi(AL f"r�AL Date Called: Address: )L k iti !mil I3uut Special Instructions: Date Wante zi 7/17 a.m. szi.en- Requester Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1 /2 — i TA ,_ A PPe6t/AL /14/ uP SI / )00 6- lAIIdu6-"�j 92 _-, Piaivi G(.f"A ezeARAILie.6 *- ®i , 1 hi./ 1!'...rvr b Mei/Art MI- /&Ui P 4, Pavibe Q - &mer it Inspector: / Alvt Date: Li 7 7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call. to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS' TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Kim £ V,Uni L, 6 "i ( Type of Inspection: Ai Caf,w f acre- K;14 L Address: /113e)1- liftL. 6t.fvb Date Called: Special Instructions: Date Want � % � a.m. �5 Request r: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4-0 DE Li Soh% - AZ iv) ri5ut3 /g bh Loses Oe hui ( ? \ iff" 6 eij note e y i P,&rtb-` f = 'tn V ` r ?'AL Aeri26 4AL., 920ti e IS 6 G it Inspector: Date: 41 47 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Mt 01L1 Project: , Type of In ection: Address: /yamla/ 2 'c. BC lib Date CalFCed: Special Instructions: � nn e � L .J Date Wanted: j j Requester: Phone No: DIApproved per applicable codes. L.! Corrections required prior to approval. COMMENTS: P/A Dat/e: Z 7 j/ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit V:11S3°114C- 1, IN tCT]ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P11roject: ICi Ceuxt ^/ Gi ete,40/ Ty a of Inspection: Gl4 id mr-Cu Address: /U360 71)6)/LA VoG I3 i b Date Called: Special Instructions: / brtoWtc Sys glADI/Wi— jg6A /" Date Wanted: 7 2, lG . s.. . Requester: Phone No: t l Approved per applicable codes. DJ Corrections required prior to approval. COMMENTS: inspector: A Avo Date: REINSPECTION FEE REQUIRED. Prior to next inspec'tion, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit IN CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ewer coadry L► LW/trey Tye of Inspection: K6Fie 1I YIA-r/od EQ ui P Address: /11O / )16,JI Lq 2 'L I Date Called: Special Instructions: plizcileis Date Want :m. 7 l e /6 p.m. Request : Phone No: 0 Approved per applicable codes. 0 Corrections required prior to approval. \gr COMMENTS: Inspector: Date: 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Of Pr oject: C Type f Inspe ion- ' ' AP/5 ® 14✓ r r eh d Caileddress- Special Instruction : 'a I L «vLq a ��C� j D h�S �f 1-�t VC) 6 �I�� T �-t Date Wante • l/t7 a.m. Requester: Phone No: _ ElApproved per applicable codes. �J Corrections required prior to approval. COMMENTS: P// Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. SPECTION NO _________ INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Ai 0-4rtej PERMIT NO. Pro' ct: �S Typ of Inspection: Igo �_u AkeC-�► Add esS ® -rut f( 6 I4 Date Cale • Special Instructions: M `.'e-7( W�j/ A- `�V� ° c=c (1 1( j,, r•-e...0 fit_-‘ Date nt(1��. / `/� l a.m. p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: IC 6 (C C o Vef Inspector: Date' REINSPECTION FEE REQUIRED. Prior to next .inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. REQUEST FOR INFORMATION / R.F.I. Project: Tukwila Library Project #: P15702 RFI #: 167 Date: 04/12/17 Contractor: Edifice Construction Co., Inc. Contract #: Subject: Mechanical Inspector's Concerns with Mechanical Room 201 © Architectural ❑ Civil ® Electrical oMechanical ❑ Structural Reference Specification: Drawing: M03-01 As -Built attached DESCRIPTION: We have attempted on two occasions to have the building and mechanical inspectors accept the equipment layouts in Mechanical Room 201. For them to do so, we need the following: 1. The Mechanical Engineer's acceptance of the mechanical equipment layout as installed, especially in regards to working space limitations as it may affect routine maintenance and operations (see as -built attached and his site visit observations on 4/12/17). Is the as constructed layout of Room 201 acceptable? 2. The Mechanical Engineer's concurrence with the final room layout, especially as regards ASPH-2 which had to be located in the northeast comer of the room rather than along the west wall. Is the location of ASPH-2 acceptable? 3. The Mechanical Engineer's confirmation that the specified equipment for ASPH-2, the Mitsubishi PUY-A24NHA4 unit may be used indoors despite the manufacturer's literature that specifies that unit to be an "Outdoor Unit". Potential Cost/Time Impact(s): YES Response Needed by: ASAP Originator: Fred Van Vurst Firm: Edifice Construction Co. Date: 04/12/17 RESPONSE/INSTRUCTIONS: 1. The mechanical equipment layout is acceptable. 36" clearance was measured on -site for equipment maintenance and electrical clearance. 2 Revised location of ASHP-2 is acceptable 3. ASHP-2 is suitable for this application. The issue with locating within the mechanical room would be heat being produced when ASHP-2 is running to cool the adjacent electrical room. This electrical room is lightly loaded and the amount of runtime of ASHP-2 will not be enough to overheat the mechanical room. In the future if the room does overheat we have controls available to open outdoor air dampers to _. V C�i it Li iiJ 1/VUl iVQ\,1. By: Benjamin Gozart WSP RFE'tIVED CITY OF TUKWILA Date: 4/13/2017 Distribution: File A/E AECOM / KCLS Contractor L PERMIT CENTER Mtn -Ole-fg Oft H66 r z r- 1 n 4 74— NMI mmmmm ' �lijwii 1 i 1 tli' nmmmmm' 1 e �p mminrtmm Y e.i uu Im17,1 {J �. i i �,1 `�LU�t uwlwwwulLL�l i n �u wwuswuw�u, L a 411 j 1 City of Tukwila Department of Community Development 12/1/2016 BENJAMIN GOZART 600 UNIVERSITY ST, STE 500 SEATTLE, WA 98101 RE: Permit No. M15-0145 KING COUNTY LIBRARY SYSTEM 14380 TUKWILA INTERNATIONAL BLVD Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will, expire on 1/17/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/17/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ache1le"Ripley Permit Technician File No: M15-0145 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development 4/1/2016 BENJAMIN GOZART 600 UNIVERSITY ST, STE 500 SEATTLE, WA 98101 RE: Permit No. M15-0145 KING COUNTY LIBRARY SYSTEM 14380 TUKWILA INTERNATIONAL BLVD Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/21/2016. Based on the above, you are hereby advised to: 1) Ca11 the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/21/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M15-0145 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0145 DATE: 11/03/15 PROJECT NAME: KING COUNTY LIBRARY SYSTEM SITE ADDRESS: 14380 TUKWILA INTERNATIONAL BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: M'\ MJ c Building Division 1111 Public Works Structural Fire Prevention is Planning Division Permit Coordinator II PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 11/05/15 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 12/03/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping El PW ❑ Staff Initials: 12/18/2013 P S F MECHANICAL INC Page 1 of 2 Home Inicio en Espanol Contact Search L&I 1. A-Z index Help 11y Secure L&I Safety Claims & Insurance Workplace Rights Trades & Licensing ashington State Department of abor & Industries P S F MECHANICAL INC Owner or tradesperson Principals REYNOLDS, JAMES P, PRESIDENT READ, ANDREW A, PRESIDENT BEARDSLEY, WARREN SCOTT, SECRETARY CRITCHLOW, JAMES D (End: 09/27/2011) Doing business as P S F MECHANICAL INC WA UBI No. 601 318 369 11621 E Marginal Way S Suite A SEATTLE, WA 98168 206-764-9663 KING County Business type Corporation Governing persons ANDREW AARON READ JAMES P REYNOLDS; JIM BEARDSLEY; WARREN S BEARDSLEY; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. PSFMEI*090NZ Effective — expiration 08/09/1991— 10/05/2017 Bond ................ Travelers Cas & Surety Co Bond account no. 105975899q $12,000.00 Received by L&I Effective date 03/13/2014 03/13/2014 Expiration date Until Canceled Bond history Insurance Liberty Mutual Fire Insurance Policy no. TB2Z91452741025 Received by L&I $1,000,000.00 Effective date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601318369&LIC=PSFMEI*090NZ&SAW= 11/18/2015 CV - HVAC LEGEND AND ABBREVIATIONS PERKINS +WILL 2/26/2013 4:00:44 PM B A ABBREVIATIONS - HVAC ABV ABOVE AC AIR CONDITIONING UNIT ACC AIR COOLED CONDENSER ACD AUTOMATIC CONTROL DAMPER AD ACCESS DOOR AHU AIR HANDLING UNIT AL ACOUSTICAL LINING ARCH ARCHITECTURAL ASHP AIR SOURCE HEAT PUMP BD BALANCING DAMPER BDD BACK DRAFT DAMPER BMS BUILDING MANAGEMENT SYSTEM BO BLANK OFF BHP BRAKE HORSE POWER BTU BRITISH THERMAL UNIT CC COOLING COIL CD CEILING DIFFUSER CFF CAP FOR FUTURE CFM CUBIC FEET PER MINUTE CG CEILING GRILLE CO CLEAN OUT COMP COMPRESSOR CR CEILING REGISTER CU CONDENSING UNIT CW CONDENSER WATER DB DRY BULB DIA DIAMETER DN DOWN DOAS DEDICATED OUTDOOR AIR SYSTEM DX DIRECT EXPANSION (E) EXISTING TO REMAIN EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE ECH ELECTRIC CABINET HEATER EDB ENTERING DRY BULB EF EXHAUST FAN EFF EFFICIENCY EG EXHAUST GRILLE EHC ELECTRIC HEATING COIL EUH ELECTRIC UNIT HEATER EWB ENTERING WET BULB EWT ENTERING WATER TEMPERATURE °F DEGREES FAHRENHEIT F FILTER FBO FURNISHED BY OTHERS FC FLEXIBLE CONNECTION (DUCT OR PIPE) FCC FIRE CONTROL CENTER FCU FAN COIL UNIT FD FUSIBLE LINK FIRE DAMPER W/ DUCT ACCESS DOOR FLR FLOOR FLA FULL LOAD AMPS FPB FAN POWERED BOX FPI FINS PER INCH FRE FIRE RATED ENCLOSURE FSD COMBINATION FIRE AND SMOKE DAMPER FT FEET GLY GLYCOL GPM GALLONS PER MINUTE GX GENERAL EXHAUST HC HEATING COIL HP HEAT PUMP OR HORSE POWER HR HOUR HW HOT WATER HX HEAT EXCHANGER ID INSIDE DIMENSION KW KILOWATT KWH KILOWATT HOURS LAT LEAVING AIR TEMPERATURE LBS POUNDS LD LINEAR DIFFUSER (CEILING, WALL, SILL OR FLOOR) LRA LOCK ROTOR AMPS LWS LOUVER WITH WIRE SCREEN LWT LEAVING WATER TEMPERATURE MAT MIXED AIR TEMPERATURE MAX MAXIMUM MBH THOUSAND BTU PER HOUR MCC MOTOR CONTROL CENTER MFG MANUFACTURER MFS MAXIMUM FUSE SIZE MIN MINIMUM MOCP MAXIMUM OVERCURRENT PROTECTION (N) NEW NC NORMALLY CLOSED NFA NET FREE AREA NIC NOT IN THIS CONTRACT NK NECK NO NORMALLY OPEN NTS NOT TO SCALE OA OUTSIDE AIR OBD OPPOSED BLADE DAMPER OD OUTSIDE DIMENSION P PUMP PD PRESSURE DROP ABBREVIATIONS - HVAC PSI POUNDS PER SQUARE INCH (GAUGE) PSIA POUNDS PER SQUARE INCH ABSOLUTE (R) EXISTING TO BE RELOCATED RA RETURN AIR RF RETURN FAN RH RELATIVE HUMIDITY RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SAD SEE ARCHITECTURAL DRAWINGS SD SMOKE DAMPER SF SUPPLY FAN SED SEE ELECTRICAL DRAWINGS SENS SENSIBLE SM SHEET METAL SP STATIC PRESSURE SQFT SQUARE FEET ST SOUND TRAP TF TRANSFER FAN TRD TRANSFER DUCT TRG TRANSFER GRILLE TX TOILET EXHAUST TYP TYPICAL UON UNLESS OTHERWISE NOTED VAR VARIABLE VAV VARIABLE AIR VOLUME VD VOLUME DAMPER VFD VARIABLE FREQUENCY DRIVE W/ WITH WB WET BULB WG WATER GAUGE WMS WIRE MESH SCREEN WO -SIZE WALL OPENING - [SIZE] WSHP WATER SOURCE HEAT PUMP (300) CUBIC FEET OR AIR PER MINUTE OR GALLONS PER MINUTE PIPING LEGEND S—CWS ---5 5--- CWR —4-5 b ----CWR HWS —1—S - HWS - -. HWR —�-5 — - HWR---�-�. 5---- RL — S -- RL---� cr—RS —S --RS ---- �- DCW —S --DCW --- f. S / 5---- D — S -- — — D ----- — �--II CONDENSER WATER SUPPLY CONDENSER WATER RETURN HOT WATER SUPPLY HOT WATER RETURN REFRIGERANT LIQUID PIPING REFRIGERANT SUCTION PIPING DOMESTIC COLD WATER MAKE-UP ARROW INDICATES DIRECTION OF FLOW PITCH PIPE DOWN IN DIRECTION OF ARROW DRAIN LINE DIRT POCKET REFRIGERANT EXPANSION VALVE VALVE IN VERTICAL MANUAL AIR VENT AUTOMATIC AIR VENT THERMOMETER PIPE SENSOR WELL (THERMOMETER) PRESSURE GAUGE AND COCK ................................................................................................... PRESSURE GAUGE WITH LOOP TEMPERATURE -PRESSURE TEST FITTING CENTER LINE PIPE SLEEVE BEAM PENETRATION ......................................... PIPE GUIDE PIPE CAP _....................................... PIPE BLIND FLANGE PIPING LEGEND (CONTINUED) (3'-0"x6'-0") r (3'-0"x6'-0") , �n- i 181 f B CgI S--Do--S IIIA:II=1Zi. S--DCW--S - a- PIPE ANCHOR PIPE GUIDE EXPANSION LOOP (SIZE AxB) UNION CAPPED PIPE WITH SHUT-OFF VALVE "Y" TYPE STRAINER WITH HOSE END BLOW OFF VALVE "Y" TYPE STRAINER BASKET TYPE STRAINER DUPLEX STRAINER ELBOW TURNED UP ELBOW TURNED DOWN BOTTOM PIPE CONNECTION TOP PIPE CONNECTION SLOPED CHANGE IN PIPE ELEVATION FLEXIBLE CONNECTION SHUT-OFF VALVE AUTOMATIC FLOW CONTROL VALVE CALIBRATED BALANCE VALVE GLOBE VALVE CHECK VALVE AUTOMATIC THREE-WAY CONTROL VALVE AUTOMATIC TWO-WAY CONTROL VALVE RELIEF VALVE ANGLE RELIEF VALVE ............._ .... _............... .............. .............__. PRESSURE REDUCING VALVE (PRV) LOCKSHIELD GLOBE VALVE BALL VALVE PUMP DUCTWORK LEGEND 18x12 18x12 18 r 1 1 "- r 5—E t 1 u z X ERy 12001 12�1 12(8 L I AREASS [IT_ SLOPING DROP IN DUCTWORK DUCT SIZE (CLEAR INSIDE DIMENSION) FIRST FIGURE INDICATES PLAN SIZE ROUND DUCT DIAMETER SIZE (CLEAR INSIDE DIMENSION) OVAL DUCT SIZE SIDE, TOP OR BOTTOM DUCT ACCESS DOOR ACOUSTIC LINING IN DUCT (DUCT SIZE NOTED INDICATES INSIDE DIMENSIONS) RECTANGULAR OR SQUARE TO ROUND OR OVAL TRANSITION FLEXIBLE CONNECTION DUCT END/CAP FLEXIBLE DUCT VOLUME DAMPER IN DUCT AUTOMATIC CONTROL DAMPER FUSIBLE LINK FIRE DAMPER WITH DUCT ACCESS DOOR BACK DRAFT DAMPER WITH DUCT ACCESS DOOR LINEAR DIFFUSER LINEAR DIFFUSER WITH PLENUM 1-WAY BLOW CEILING DIFFUSER 3-WAY BLOW 2-WAY BLOW 4-WAY BLOW CEILING DIFFUSER WITH FLEXIBLE DUCT CONNECTION RETURN/EXHAUST REGISTER OR GRILLE RETURN/EXHAUST REGISTER OR GRILLE WITH FLEXIBLE DUCT CONNECTION TRANSFER GRILLES ON BOTH SIDES OF PARTITION OR WALL (SIZE) WALL OPENING ABOVE HUNG CEILING (SIZE) SUPPLY REGISTER WITH AIR OUTLET DEVICE DESIGNATION RETURN OR EXHAUST REGISTER OR GRILLE WITH AIR INLET DEVICE DESIGNATION TERMINAL UNIT WITH/WITHOUT HEATING COIL DUCTWORK LEGEND (CONTINUED) 16x6S-TI: 8x6 16x6 S 8x6 f X 177 I f S Iv P i DUCT SPLIT WITH SPLIT SIZE RADIUS ELBOW ELBOW WITH TURNING VANES RECTANGULAR BRANCH TAKEOFF WITH BALANCING DAMPER RECTANGULAR SUPPLY DUCT UP RECTANGULAR SUPPLY DUCT DOWN RECTANGULAR RETURN OR EXHAUST DUCT UP RECTANGULAR RETURN OR EXHAUST DUCT DOWN ROUND DUCT, UP ROUND DUCT, DOWN ......................_.........................................-........................... BEAM PENETRATION SLOPING RISE IN DUCTWORK CONTROLS LEGEND E ®# TOTALIZING BTU METER EMERGENCY BREAK GLASS SWITCH FOR EQUIPMENT SHUT -DOWN FLOW MEASURING STATION FLOW SWITCH CARBON MONOXIDE SENSOR WITH ZONE DESIGNATION TEMPERATURE SENSOR/THERMOSTAT WITH ZONE OR EQUIPMENT DESIGNATION DUCT SMOKE DETECTOR SUPPLIED BY ELECTRICAL TRADE, INSTALLED BY MECHANICAL TRADE STATIC PRESSURE SENSOR WITH DESIGNATION REFRIGERANT SENSOR WITH DESIGNATION MISCELLANEOUS ri DP S 3-24 CD-1,12x12 (550) LD-A,48x1,80 (300) DIFFERENTIAL PRESSURE SENSOR DIFFERENTIAL PRESSURE SWITCH NEW WORK OVAL DIAMETER RISER DESIGNATION SECTION DESIGNATION DETAIL DESIGNATION CI RISER SERVICE RISER NUMBER SECTION NUMBER DRAWING NUMBER DETAIL NUMBER DRAWING NUMBER EQUIPMENT DESIGNATION EQUIPMENT TYPE EQUIPMENT FLOOR AND NUMBER 3-24 TERMINAL DESIGNATION AIR OUTLET/INLET DEVICE DESIGNATION LINEAR DIFFUSER LD-A48x180 DEVICE DESIGNATION (300) L-- THE NUMBER ON THE FLOOR FLOOR OR LEVEL CD-1,12x12 (550) RADIANT FLOOR MANIFOLD TYPE NECK OR FACE SIZE CFM LENGTH & SLOT SIZE PLENUM INLET SIZE CFM HVAC DRAWING LIST M00-01 HVAC LEGEND & ABBREVIATIONS M00-02 HVAC SCHEDULES M00-03 HVAC SCHEDULES M01-00 HVAC WASHINGTON STATE ENERGY CODE FORMS M01-01 HVAC SITE PLAN M02-00 HVAC RADIANT FLOOR PLAN M02-01 HVAC FLOOR PLAN - LEVEL 01 M02-02 HVAC FLOOR PLAN - LEVEL 02 M02-03 HVAC ROOF PLAN M03-01 HVAC ENLARGED PLANS M03-02 HVAC SECTIONS M04-01 HVAC HYDRONIC DIAGRAM M05-01 HVAC DETAILS M05-02 HVAC DETAILS M05-03 HVAC DETAILS M06-01 HVAC CONTROL DIAGRAMS M06-02 HVAC CONTROL DIAGRAMS C Permit Plan raview approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Meld Copy and ponditions is acknowledged: By: Date: I City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 1 SERRATE PERMIT REQUIRED FOR: 0 Mechanical ret &Plumbing as Piping Cis,. of Tukwila 7'1VDiViSION -ems l EV ED FOR G CODE COMPLIANCE ROVFD DDJV1620115 S IV? City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 0 3 2015 PERMIT CENTER B A 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 King County Library System 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Sheet Information Job Number 161028.000 Drawn BG Checked TM Approved TM Title HVAC LEGEND AND ABBREVIATIONS Sheet 2/26/2013 4:00:44 PM BRANCH CIRCUIT CONTROLLER SCHEDULE DESIGNATION LOCATION / SERVICE MANUF. MODEL NUMBER MCA VOLTAGE / PHASE WEIGHT (LBS) NOTES BC-1 MECH 201 MITSUBISHI CMB-P1016NU-HA 1.65 208 / 1 33 1, 2 GENERAL NOTES: A) REFERENCE DRAWINGS FOR LENGTH OF PIPING FROM FCU'S TO BC CONTROLLER. SEE PIPING SCHEMATIC ON M06-02 NUMBERED NOTES: 1. PROVIDE DIAMONDBACK BV SERIES ISOLATION BALL VALVES FOR EACH REFRIGERANT CIRCUIT TO ALLOW FOR MAINTENANCE FOR INDIVIDUAL FCU'S OR HX UNITS. 2. ROUTE CONDENSATE TO MECHANICAL ROOM DRAIN. RADIANT FLOOR MANIFOLD SCHEDULE MANIFOLD AREA (SOFT) LOCATION SERVED COOLING HEATING TUBING FLOW NOTES SET- POINT (F) FLOOR SURFACE (F) BTU H / PER SOFT TOTAL MBH EWT (F) LWT (F) SET- POINT (F) FLOOR SURFACE (F) BTU/H PER SOFT TOTAL MBH EWT (F) LWT (F) TYPE SPACING OC (IN) NUMBER OF LOOPS LOOP LENGTH (FT) GPM HEAD LOSS (Ff) RFM-1 900 STAFF NORTH - - - - - - 68 77 18 16200 105 95 5/8" hePEX 9 4 265 3.6 4.4 RFM-2 610 STAFF SOUTH 76 69 8 4575 58 66 68 75 13 7930 105 95 5/8" hePEX 9 3 240 1.8 2.0 RFM-3 500 CHILDRENS - - - - - - 68 78 20 10000 105 95 5/8" hePEX 6 4 250 2.3 1.8 RFM-4 1245 MOSAIC 76 69 9 11187 58 66 68 78 19 23617 105 95 5/8" hePEX 6 10 330 5.7 2.4 RFM-5 720 MEETING ROOM - - - - - - 68 78 19 13680 105 95 5/8" hePEX 6 3 400 3.0 7.7 RFM-6 3075 MAIN LIBRARY 76 69 8 24616 58 66 68 75 13 40000 105 95 5/8" hePEX 9 10 400 8.9 6.3 RFM-7 715 SOUTH LIBRARY 76 68 11 7865 58 66 68 84 31 22165 105 95 5/8" hePEX 6 4 305 4.7 8.4 RFM-8 1420 WEST LIBRARY 76 68 11 15620 58 66 68 84 32 45440 105 95 5/8" hePEX 6 7 400 9.6 14.1 NOTES: 1) AIR -SOURCE HEAT PUMP SCHEDULE DESIGNATION LOCATION MANUF. MODEL NUMBER REF COOLING CAPACITY HEATING CAPACITY POWER PER MODULE (MCA) VOLTAGE/ PHASE EER/ COP WEIGHT (LBS) NOTES TOTAL (MBH) TOTAL (MBH) ASHP-1 MECH 201 MITSUBISHI PURY-P288TSKMU-A 410A 288.0 320.0 53 208V / 3 18 / 3.3 1,430 1, 2, 3 ASHP-2 MECH 201 MITSUBISHI PUY-A24NHA4 410A 24 - 18 208 V / 1 10.6 165 2, 3 NOTES: 1. P288 UNIT CONSISTS OF TWO PURY-144TKMU-A MODULES THAT ARE CONNECTED IN TANDEM. PROVIDE ALL NECESSARY PARTS TO OPERATE AS A SINGLE UNIT. 2. SEE SHEET M06-02 FOR PIPING AND WIRING DIAGRAM. 3. STARTER AND DISCONNECT BY DIVISION 26. HYDRONIC PUMP SCHEDULE DESIGNATION LOCATION SERVICE MANUF. MODEL NUMBER TYPE GPM HEAD (Fr H2O) MINIMUM EFFICIENCY (PERCENT) WORKING PRESSURE (PSIG) MOTOR VFD NOTES RPM BRAKE HP NON -OVERLOADING HP VOLTAGE/ PHASE CWP-1 MECH 201 CONDENSER WATER BELL & GOSSET BASE -MOUNTED 1510 65 60 56 150 1750 1.78 2 208/3 Y CWP-2 MECH 201 CONDENSER WATER BELL & GOSSET BASE -MOUNTED 1510 65 60 56 150 1750 1.78 2 208/3 Y CP-1 MECH 201 HEX HEAT PUMPS BELL & GOSSET INLINE SERIES 80 45 40 56 150 1750 0.84 1.5 208/3 Y CP-2 MECH 201 HEX HEAT PUMPS BELL & GOSSET INLINE SERIES 80 45 40 56 150 1750 0.84 1.5 208/3 Y CP-3 MECH 201 RADIANT FLOOR BELL & GOSSET INLINE SERIES 80 45 70 48 150 1750 1.64 3 208/3 Y NOTES: 1) HYDRONIC HEAT EXCHANGER SCHEDULE DESIGNATION LOCATION BASIS OF DESIGN WATER WEIGHT (LBS) MCA VOLTAGE NOTES HEATING MBH COOLING MBH GPM FT HD HEAT EWT (F) HEAT LWT (F) COOL EWT (F) COOL LWT (F) HX-01 MECH ROOM 201 PWFY-P72NMU 79.8 72 12.0 86 105 73 58 85 0.1 208 / 1 1, 2 HX-02 MECH ROOM 201 PWFY-P72NMU 79.8 72 12.0 86 105 73 58 85 0.1 208 / 1 1, 2 NOTES: 1) PROVIDE EACH HX UNIT WITH A WATER FLOW SAFETY SWITCH TIED TO THE HX UNIT TERMINAL TB-142A PUMP INTERLOCK. 2) STARTER AND DISCONNECT BY DIVISION 26. AIR SEPARATOR SCHEDULE DESIGNATION MANUF. MODEL NUMBER SERVICE INLET SIZE (INCHES) SYSTEM FLOW (GPM) MAX SYSTEM TEMP(E.RATURE WORKING PRESSURE (PSIG) NOTES AS-1 SPIROVENT JUNIOR VDR200FT HOT WATER 2 40 270 150 NOTES: 1) EXPANSION TANK SCHEDULE DESIGNATION MANUF. MODEL NUMBER SERVICE TANK VOLUME (GALLONS) ACCEPTANCE VOLUME (GALLONS) WORKING PRESSURE (PSIG) NOTES ET-01 EXTROL AX-15V HOT WATER 8 2.4 125 - ET-02 EXTROL AX-15V CONDENSER WATER 8 2.4 125 - NOTES: 1) 5 FAN COIL UNIT SCHEDULE DESIGNATION MITSUBISHI MODEL NUMBER BC CONTROLLER SERVICE FAN CFM ESP (IN WG.) COOLING HEATING MCA VOLTAGE / PHASE UNIT WEIGHT (LBS) NOTES TOTAL MBH SENS MBH EAT (°F) LAT (°F) TOTAL MBH EAT (°F) LAT (°F) FCU-1 PEFY-P24 BC-1 MEETING ROOM 104 800 0.5 24 13.7 78 60 27 70 80 2.73 208/1 100 1, 2 FCU-2 PEFY-P24 BC-1 MEETING ROOM 104 800 0.5 24 5.1 78 60 27 70 80 2.73 208/1 100 1, 2 FCU-3 PMFY-P06 BC-1 STAFF 116 230 0.5 6 5.5 78 60 6 70 80 0.25 208/1 40 1, 2 FCU-4 PEFY-P15 BC-1 STAFF 117 600 0.5 12 11.5 78 60 17 70 80 1.45 208/1 100 1, 2 FCU-5 PEFY-P15 BC-1 STAFF 117 600 0.5 12 11.5 78 60 17 70 80 1.45 208/1 100 1, 2 FCU-6 PEFY-P15 BC-1 CHILDRENS 110 600 0.5 12 11.5 78 60 17 70 80 1.45 208/1 100 1, 2 FCU-7 PEFY-P15 BC-1 CHILDRENS 110 600 0.5 12 11.5 78 60 17 70 80 1.45 208/1 100 1, 2 FCU-8 PKFY-P12 - DATA RACK (ELEC ROOM) 300 0.5 12 11.5 78 60 13.5 70 80 0.26 208/1 40 1, 2 FCU-9 PEFY-P54 BC-1 MAIN LIBRARY 1000 0.5 54 53 78 60 60 70 80 3.51 208/1 93 1, 2 FCU-10 PEFY-P54 BC-1 MAIN LIBRARY 1000 0.5 54 53 78 60 60 70 80 3.51 208/1 93 1, 2 FCU-11 PEFY-P54 BC-1 MAIN LIBRARY 1000 0.5 54 53 78 60 60 70 80 3.51 208/1 93 1, 2 FCU-12 PEFY-P24 BC-1 MOASAIC 800 0.5 24 13.7 78 60 27 70 80 2.73 208/1 100 1, 2 FCU-13 PMFY-P12 BC-1 BREAKROOM / STAFF 300 0.5 12 11.5 78 60 13.5 70 80 0.26 208/1 40 1, 2 GENERAL NOTES: A. SEE ASHP-1 SCHEDULE FOR EFFICIENCY OF SYSTEM. B. PROVIDE CONDENSATE DRAIN FOR EACH UNIT. C. PROVIDE AUXILIARY CONDENSATE PUMP AS NEEDED TO MAINTAIN SLOPE/FLOW TO DRAIN. D. SEE SHEET M06-02 FOR PIPING AND WIRING SCHEMATIC DIAGRAM. NUMBERED NOTES: 1. PROVIDE ALL FAN COIL UNITS WITH ISOLATION VALVES. 2. PROVIDE MITSUBISHI TEMPERATURE SENSOR LOCATED AT THE RETURN AIR INLET OF THE UNIT. BMS SYSTEM WILL CONTROL ON/OFF OF FAN COILS. AIR HANDLING UNIT SCHEDULE (DOAS) DESIGNATION LOCATION/SERVICE MANUF. MODEL NUMBER TOTAL AIRFLOW CFM SUPPLY FAN EXHAUST FAN ENERGY RECOVERY WHEEL HEATING COIL AIR FILTER ELECTRICAL DATA NOTES EXT SP IN. WG MOTOR HP -. C/) W MOTOR HP SUMMER WINTER CAPACITY (MBH) W J g 8 g g PD IN WG. (INITIAL) PD IN WG. (FINAL) SUP. FILTER (MERV) RET. FILTER (MERV) VOLTAGE / PHASE MCC (AMPS) MOCP (AMPS) WEIGHT (LBS) EFFICIENCY CAPACITY (MBH) EFFICIENCY CAPACITY (MBH) AHU-1 MECH 201 GREENHECK ERH-20H-15H 2000 2000 1.25 2 2000 1.25 3 85 78 72% 6.5 23 58 71% 30.0 29.4 2.5 105 81 66 72 0.1 0.08 8 13 208/3 22.3 30 1,300 1, 2, 3, 4, 5 GENERAL NOTES: A) AHU-1 TO BE PROVIDED WITH A SINGLE POINT POWER CONNECTION. 0 il 1. STARTER AND DISCONNECT BY DIVISION 26. 2. PROVIDE FACTORY MOUNTED INTERNAL SPRING ISOLATION. 3. PROVIDE DUCT SMOKE DETECTOR FOR RETURN AIR DUCTWORK. SEE SHEET M06-01 DETAIL 1 FOR LOCATION. 4. PROVIDE WITH UNIT MOUNTED OUTDOOR AIR AND EXHAUST AIR DAMPERS. r 5. PROVIDE WITH FROST CONTROL. REVIF- E FOR ODE COMPLIANCE s K[ APPROVED NOV 1 6 2015 , 4 3 PERKINS +WILL 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library D 14242 Tukwila International Boulevard Tukwila, WA 98168 King County Library System ate% 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Job Number 2 RECEIVED CITY( OF TUKWILA NOV 03 2015 HVAC SCHEDULES Copyright © 2012 Perkins+Will 5 4 3 2 c B A 2/26/2013 4:00:44 PM WATER TO WATER HP SCHEDULE DESIGNATION LOCATION SERVICE MANUF. MODEL NUMBER REFRIGERANT COOLING HEATING VOLTAGE/ PHASE MCA WEIGHT NOTES CAPACITY (MBH) SOURCE LOAD CAPACITYM ( ) SOURCE LOAD COP EWT(F) LWT (F) GPM PD (FT H20) I EWT(F) LWT (F) GPM PD (FT H2O EWT(F) LWT (F) GPM PD (FT H20)EWT(F) LWT (F) GPM PD (FT H2O) WSHP-1 MECH 201 HOT/CHILLED WATER LOOP FLORIDA HEAT PUMP WW120 R-410A 143 70 83 25 9 66 55 25 9 20 139 55 46 25 10 95 106 25 8 5 208/3 46.3 650 1, 2, 3, 4, 5 NOTES: 1. STARTER AND DISCONNECT 2. PROVIDE LONWORKS 3. PROVIDE WITH COMPRESSOR 4. PROVIDE 75 VA 5. PROVIDE A SHUTDOWN BY DIVISION 26. CONTROLS INTERFACE. BLANKET TO REDUCE RADIATED NOISE. TRANSFORMER TO HANDLE LARGE EXTERNAL CONTROL LOADS. RELAY FOR ON/OFF CONTROL FROM A REMOTE 24 VOLT SIGNAL. FAN SCHEDULE DESIGNATION SERVICE BASIS OF DESIGN TYPE OPERATING CFM ESTIMATED STATIC PRESSURE (IN WG) RPM MOTOR WEIGHT (LBS) VFD NOTES HP (WATTS) VOLTAGE/PHASE EF-1 MECHANICAL ROOM 120SQN17DEC CENTRIFUGAL 325 OR 1000 0.03 534 0.5 120/1 125 N 1, 2, 3, 4 1. FAN TO RUN CONTINUOUSLY AT 350 CFM. 2. DISCONNECT PROVIDED AND WIRED BY DIV. 26. NOTES: 3. PROVIDE LONWORKS CONNECTIONS FOR CONTROL INTEGRATION WITH TRIDIUM JACE BMS SYSTEM. 4. PROVIDE CONTROL CONNECTION TO REFRIGERANT DETECTION SYSTEM IN MECHANICAL ROOM TO ALLOW FAN TO RUN WHEN ALARM SIGNAL IS RECEIVED FROM THE REFRIGERANT DETECTION SYSTEM. AIR INLETS AND OUTLETS SCHEDULE DESIGNATION MANUF. MODEL NUMBER TYPE F SERVICE DIMFACE ONS NOTES CD -A TITUS TMS SUPPLY 24x24 1 CD-B TITUS TMS SUPPLY 12x12 1 EG-A TITUS PAR EXHAUST 24x24 1 EG-B TITUS PAR EXHAUST 12x12 1 ER -A TITUS 3FL EXHAUST SEE DWG 1, 2 SR -A TITUS 272FL SUPPLY SEE DWG 1, 2 LD-A TITUS FLOWBAR SUPPLY 2' LONG, 1" SLOT 1, 3 NOTES: 1. VERIFY COLOR AND CEILING FINISH WITH ARCHITECT. 2. FACE DIMENSIONS ON PLANS 3. PROVIDE WITH EGGCRATE DIFFUSER PLATE UPSTREAM OF LINEAR DIFFUSER. 4. PROVIDE BORDER TYPE 11. RELIEF HOOD SCHEDULE DESIGNATION LOCATION/ SERVICE MANUFACTUER SIZE (IN) CFM STATIC PRESSURE DROP (IN) THROAT VELOCITY (FPM) THROAT AREA (SF) NOTES RH-1 ROOF / ASHP-1 GREENHECK WRH 56X80 24,000 0.152 1000 24 1 NOTES: 1. PROVIDE WITH BIRD SCREEN. VAV TERMINAL UNIT SCHEDULE DESIGNATION LOCATION MANUF. MODEL NUMBER CFM SETTING PRESSURE LOSS AT MAXIMUM CFM (IN. WG.) INLET DUCT SIZE (INCHES) NOTES X m Z m VAV-1 MEETING ROOM TITUS DESV 250 50 0.5 6 1 NOTES: 1. BOX WILL PROVIDE MINIMUM 50 CFM UNTIL CO2 CONCENTRATION RISES AND BOX WILL MODULATE BETWEEN 50-250 CFM TO MAINTAIN CO2 SETPOINT OF 1000 PPM. 5 1 4 1 3 1 2 c B r REVIEWED FOR CODE COMPLIANCE NOV 16 2015 e Ctyca Tukwila 1 BUILDNG DIVISION RECEIVED CITY OF TUKWILA NOV 0.3 2015 PERMIT. CENTER PERKI NS +WILL 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 ing County Library System 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions ISSUE Sheet Information Job Number 161028.000 Drawn BG Checked TM Approved TM HVAC SCHEDULES 'ght © 2012 Perkins+Will 5 4 3 2 1 B A 2/26/2013 4:00:44 PM 5 .46 xMechanllcal Permit_PlansgCheckl€st MESH Pagel of 3 - 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address TUKWILA LIBRARY Date 10/16/2015 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS Equipment Sizing & Performance YES C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 M01-00 YES C403.2.2 Equipment and system sizing Output capacity of heating and cooling equipment and systems do not exceed calculated loads, note exceptions taken M01-00 YESventilation C403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical is capable of being reduced to minimum requirement per IMC MO 1-00 YES C403.2.3 & C403.2.3.2 &efficiency C403.2.12.1 Equipment minimum Provide equipment schedules or complete MECH-SUM tables with type, capacity, efficiency, test standard (or other efficiency source) for at mechanical equipment M01-00 YES C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for at motors; note except. M01-00 YES C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table C403.2.10.1(1) M01-00 YES C403.2.10.3 & C403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. M01-00 NA / C403.2.3 Maximum air cooled chiller capacity Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit N/A N A / C403.2.1 Non-standard water-cooled chillers Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non-standard operational conditions N/A N A / C403.2.12.1.2 Centrifugal fan cooling towers Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan open circuit cooling towers N/A N/A C403.2.3 Forced air furnace and unit heaters Indicate intermittent ignition or IID, flue/draft damper & jacket loss NIA YES C403.2.3.3 Packaged electric heating/cooling equipment List equipment required to be heat pumps on schedule MO1-00 N/A C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer) NIA HVAC System Controls & Criteria YES C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including perimeter systems M01-00 N/A C403.2.4.1.1 hHeat eat pump supplementary Indicate staged heating (compression/supplemental) & outdoor lock -out p N/A YES C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & cooling M01-00 YES C403.2.4.3 Automatic setback and shutdown Indicate zone t-stat controls with required automatic setback & manual override M01-00 YES C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load conditions M01-00 YES C402.4.5.2 & C403.2.4.4 Dampers Indicate location of OSA, exhaust, relief and retum air dampers; include AMCA rated leakage and control type (motorized or gravity; note exceptions M01-00 N/A C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls N/A N/A C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions N/A N/A C403.2.4.6 Combustion heating equipment Indicate modulating or staged control N/A NA / C403.2.4.7 Group R1 hotel/motel systems Indicate method for guest room automatic setback & set-up of 5°F minimum N/A N/A YES YES N/A N/A N/A YES N/A YES C403.2.4.8 / C403.2.5.1 C403.2.5.2 C403.2.5.3 C403.2.5.4.1 C403.2.5.4.2 C403.2.6.1 C403.2.6.2 C403.2.6.3 c Group R2/R3 dwelling unit systems Demand controlled ventilation Occupancy sensors Enclosed loading dock/parkinggarage ventilationtionsystem Kitchen exhaust hoods Laboratory exhaust systems Energy recovery - ventilation systems Energy recovery - condensate systems Energy recovery - condenser systems Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback periods; note exceptions taken indicate high -occupancy spaces and systems requiring DCV Indicate spaces requiring occupancy -based system control and method; or alternate means provided to automatically reduce OSA when partially Indicate enclosed loading dock and enclosed parking garage ventilation activation and control method Indicate kitchen hoods requiring make-up air, indicate make-up air source and conditioning method Indicate lab exhaust systems requiring heat recovery, method & efficiency; or alternative method taken (VAV, semi -conditioned makeup, or CERM calculation) Indicate ventilation systems requiring ER, method & efficiency;. note exceptions Indicate on -site steam heating systems requiring energy recovery Indicate remote refrig. condensers requiring ER and use of captured energy N/A M02-01 M02-01 N/A N/A N/A M00-02 N/A M00-02 tea. ec a h nical _Perm aecklist - Pa e 3 of 3 MECH-CHK _ it- Plans==C 2012 Washington State Energy Cade Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address TUKWILA LIBRARY Date 10/16/2015 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes COMPLEX SYSTEMS; CONTINUED Specific System Requirements N/A C403.4.2 & c403.2.12 Variable flow control - fans Indicate fans requiring variable flow control and method N/A N/A C403.4,2.1 VAV fan static pressure sensors Indicate sensor locations on plans; include at least one sensor per major duct branch N/A N/A C403.4.2.Z VAV fan static pressure setpoint Indicate fan system static pressure setpoint hocnd „n zone requiring most pressure N/A N/A C403.4.5 VAV systems serving multi- zones Indicate supply air systems serving multiple zones that are required to be VAV, method of primary air control, and zones served; note exceptions taken N/A N A / C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads N/A N /A C403.4 Large capacity cooling systems Indicate method of multi -stage or variable control for building cooling system capacity > 300 tons N/A N/A C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method N/A N/A C403.4.3 system pacity boiler Indicate multi -stage or modulating burner for single boilers > 500,000 btuh N/A N/A C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers N/A N/A C403.a.3.5 Chiller / boiler plant pump isolation Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers & boilers when not in use N/A YES C403.4.2 & C403.4.3.6 Variable flow control - pumps Indicate pumps requiring variable flow control &method M01-00 N A J & 0403.4.4 & Ca03.4.4 Varcooling towers flow control - cooling Indicate cooling tower fans requiring variable flow control and method N/A YES 0403.4.3.4 Hydronic system part load controls n ,a,, „tea, y ,„ , G, rYa« ay ,,,a , av nco aNauuny , av u„ a tea, y reset supply water temp AND reduce flow by a 50 /° for systems > 300,000 �, y M01-00 YES C403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling mode scheduling and changeover temperature range M01-00 YES C403.4.3.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide min. 20"F water supply temp deadband between heat rejection and heat addition modes M01-00 N A / C403.4.3.3 Water loop heat pump - heat rejection Provide heat exchanger that separates cooling tower and heat pump loop in Climate Zone 5 N/A N/A C403.4.3.3.3 Water loop heat pump - Isolation Indicate 2-way isolation valve on each heat pump and variable flow control for systems with total pump power > 10 hp N/A N/A C403.4.6 Condenser water heat recovery Indicate system provided to pre -heat service water and efficiency NiA N A j C403.5 Cooler/ freezer - anti -sweat heaters Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters N/A N/A C403.5 / 6 Cooler) freezer - evaporator and condenser fans Indicate motor type for evaporator and condenser fans < 1 hp N/A SERVICE WATER HEATING Service Wa er Systems YES C404.2 Water -heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity. efficiency, test standard (or other efficiency source) M01-00 YES C404.3 Temperature controls Indicate temperature controls have required setpoint capability M01-00 YES C404.d Heat traps Indicate piping connected to equipment have heat traps on supply & discharge M01-00 YES C404.5 Insulation under water heater Indicate R-10 insulation under tank M01-00 YES YES NA j Pools & In -Ground N/A N/A N/A N/A N/A C404.6 C404.7 / 8 9 Permanently C404.10.1 C404.10-1 ! 2 C404.10.3 C404.10.3 C404.10.4 Service water piping Insulation Circulation systems and heat trace shut-off Group R-2 service hot water meters Installed Spas Pool heating equip min. efficiency Pool heater on !off controls Pool covers Pool assembly insulation Indicate R-value of insulation on piping; note exceptions taken Indicate shut-off capability based on occupancy and periods of limited demand Indicate method of usage metering for dwell. units served by central HW system Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other eftsource): heat pump heaters z 4 COP Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting; or Indicate vapor retardant cover and insulation rating as required Indicate rating of insulation on sides and bottom of pools heated to > 90°F Indicate method, exhaust air temperature reduction and recovered energy use M01-00 M01-00 N/A N/A N/A N/A N/A N /A Heat recovery 4 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 echancal t111Y.1c 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address TUKWILA LIBRARY Date 10/16/2015 14242 TUKWILA INTERNATIONAL BLVD For Building Dept. Use TUKWILA, WA 98168 Applicant Name: wsP Applicant Address: 600 UNIVERSITY STREET, SEATTLE, WA 98101 Applicant Phone: 206-342-9900 Project Description Briefly describe mechanical system type and features. Includes Plans NEW LIBRARY WITH GROUND LOOP HEAT PUMP SERVING RADIANT/CHILLED FLOOR WITH BACK-UP AiR COOLED VRF FOR PEAK HEATING AND COOLING. DOAS PROVIDES 100% OUTSIDE AIR AND OPERABLE WINDOWS AND SKYLIGHTS PROVIDE NATURAL VENTILATION WHEN APPROPRIATE. Drawings must contain notes requiring compliance with commissioning provisions per Section C408 Compliance Option Simple System o Complex System Systems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency` Heat Recovery Y/N Fan Equipment Schedule Equip. ID Equip Type Brand Namet Model No.1 CFM spt HP/BHP Flow Controls Location of Service Service Equip. ID Water Equip Type Heating Equipment Brand Name' Schedule Model No.1 Input Capacity Sub - Category EF7 Location of Service 1 If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Economizer exception number per Mechanics! ecklist _°° P - g - • f = = ►� . - - . L' Revised June 2013 Permit P! s C 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Project Address TUKWILA LIBRARY Date 10/16/2015 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na} Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued YES C403.2.12 Variable flow control - fans/pumps Indicate fan & pump motors requiring VF control & method (VSD or equiv controls) M01-00 N/A C403.2.12.1 Variable flow control - cooling towers Indicate cooling tower fans requiring variable flow control and method N/A N/A C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooling demand; or exception taken NIA N/A C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 btuh N/A YES C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for trending and demand response setpoint adiustment M01-00 Ducting Systems YES C403.2.7.1 & C403.2.7.3 Duct construction Indicate all ductwork constructed and sealed per IMC, C402 leakage requirements and IBC vapor retarder requirements M01-00 YES C403.2.7.3.1-: Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans M01-00 N A / C403.2.7.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed N/A YES C403.2.7.1 / 2 Duct insulation Indicate R-value of insulation on ductwork M01-00 Piping Systems YES C403.2.8 Piping insulation Indicate R-value of insulation on piping M01-00 YES C403.2.8.1 Piping insulation exposed to weather Indicate method of protection from damage/degredation M01-00 SIMPLE SYSTEMS Qualifying Systems N/A C403.3 Qualifying single zone systems Verify unitary or packaged equipment does not exceed capacity limits, does not have active humidifcation or simultaneous heating/cooling N/A N/A C403.3 Qualifying 2-pipe heating systems Verify 2-pipe heating -only system does not exceed capacity limits N/A N/A C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 N/A Simple System Economizers N/A G403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. N/A N/A C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception N/A N/A C403.3.1.1.3 Air economizer high limit controls Indicate high limit shut-off control method per Table C403.3.1.1.3(2) N/A N/A C403.1.1.2 Integrated air economizer operation Indicate capability for partial air economizer operation for systems with capacity > 65,000 btuh NIA N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) N/A COMPLEX SYSTEMS Complex System Economizers Indicate cooling systems requiring economizer controls; note in equip N/A C403.4.1 Air economizer required N/A sched. C403.4.1.4 Economizer heating system Verify control method of HVAC systems with economizers does not N/A impact increase building heating energy usage during normal operation N/A N/A Integrated economizer Indicate capability for partial economizer operation for air or water econo C403.4.1.3 operation systems N/A Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb N/A N/AOSA C403.4.1.2 Water economizer Indicate precooling coils and heat exchangers do not exceed pressure drop N/A maximum pressure drop limit N/A YES C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with M01-00 exception(s) 3 2012 WASHINGTON STATE ENERGY CODE (WSEC) GENERAL NOTES THE PROJECTS COMPLIANCE WITH THE WASHINGTON STATE ENERGY CODE IS OUTLINED IN THE WA STATE MECHANICAL NREC COMPLIANCE FORMS. FURTHER INFORMATION IS PROVIDED BELOW FOR CLARITY. Code Section Code Provision INFORMATION REQUIRED GENERAL PROVISIONS Equipment Sizing & Performance C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 C403.2.2 Equipment and system sizing Output capacity of heating and cooling equipment and systems do not exceed calculated loads, note exceptions taken C403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; See AHU schedule for ventilation volume provided. C403.2.3 & C403,2,3.2 & C403.2.12.1 Equipment minimum efficiency See Mechanical Schedule sheets for equipment efficiency. C403.2.13 Electric motor efficiency See Mechanical Schedule sheets for equipment efficiency. C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table C403.2.10.1(1) C403.2.10.3 & C403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. C403.2.3.3 Packaged electric heating/cooling equipment List equipment required to be heat pumps on schedule HVAC System Controls & Criteria C403.2.4.1 Thermostatic controls Thermostats are shown on M02-00 and M02-01 C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & cooling C403.2.4.3 Automatic setback and shutdown Provided by Building Management System. See Specification 23 09 93 C403.2.4.3.3 Automatic (optimum) start Provided by Building Management System. See Specification 23 09 93 C402.4.5.2 & C403.2.4.4 Dampers OSA and relief dampers located in AHU-1. C403.2.5.1 Demand controlled ventilation Occupancy Sensor shown on Sheet M02-01 for Meeting Room. C403.2.5.2 Occupancy sensors Occupancy Sensor shown on Sheet M02-01 for Meeting Room. C403.2.6.1 Energy recovery - ventilation systems AHU-1 Schedule shows energy wheel recovery data. C403.2.6.3 Energy recovery -condenser systems ASHP-1 Schedule shows VRF energy recovery. C403 212 Variable flow control - fans/pumps See Schedule Sheets M00-01 and M00-02 for Variable Flow Control Pumps C403.2.4.10 DDC system capabilities See Control Drawings M06-01 and M06-02 for DDC diagrams. See Specification 23 09 for trending and reporting capabilities. 93 Ducting Systems C403.2.7.1 & C403.2.7.3 Duct construction Ductwork to be constructed and sealed per IMC, see specification 23 31 00 C403.2.7.3.1-3 Duct pressure classifications See specifcation 23 31 00 for duct pressure classification. C403.2.7.1 / 2 Duct insulation See specifcation 23 07 00 for duct insulation requirements. Piping Systems C403,2.8 Piping insulation See specifcation 23 07 00 for Piping insulation requirements. C403.2.8.1 Piping insulation exposed to weather COMPLEX SYSTEMS Complex System Economizers C403.4.1.2 Air economizer exceptions Air economizer exception (6) is being utilized for this project. Specific System Requirements C403.4.2 & C403A.3.6 Variable flow control - pumps Variable flow control for pumps is indicated on the pump schedule on sheet M00-02 Hydronic system part loadC4034.3.4 controls See Specification 23 09 93 for part -load ad resettco control sequence. e. C403.4.3.2 Two -pipe changeover systems See specification 23 09 93 for mode scheduling and changeover temp range, C403.4.3.3.1 Water loop heat pump - deadband See specification 23 09 93 for deadband for heat rejection and heat addition. SERVICE WATER HEATING Service Water Systems C404.2 Water -heating equip min. efficiency See sheet P00-01 for Water Heater efficiency C404.3 Temperature controls See Specification 22 33 00 C404.4 Heat traps See Specification 22 33 00 C404.5 Insulation under water heater R-10 minimum is provided beneath water heater. See Detail 7/P05-01 C404.6 Pipe Insulation See Specification 22 07 19 for insulation requirements. C404.7 Circulation systems and heat trace shut-off See Specfication 22 33 00 for circulation controls shut-off. 2 Project: KCLS - Tukwila Library Project No: W12.10450.00 Load Calculations ZONE Square Footage People Venti€ation CFM/SF Vent CFM/Person Total Vent CFM BREAKROOM 140 3 0.06 5 23 CHILDRENS 500 8 0.12 5 100 ELECTRICAL - - 0.00 0 0 JANITOR - - 0.00 0 0 LIBRARY PERIMETER 1 955 18 0.12 5 205 LIBRARY PERIMETER 2 290 12 0.12 5 95 LIBRARY PERIMETER 3 710 14 0.12 5 155 MAIN LIBRARY 3290 33 0.12 5 560 MECHANICAL ROOM - - 0.00 0 0 MEETING ROOM 720 40 0.06 5 243 MOSAIC 1020 10 0.12 5 172 RESTROOMS - - 0.00 0 0 STAFF 1 440 6 0.06 5 56 STAFF 2 320 3 0.06 5 34 STAFF OFFICE 100 1 0.06 5 11 STAFF TOILET - - 0.00 0 0 STUDY ROOM 1 100 5 0.06 5 31 STUDY ROOM 2 70 4 0.06 5 24 VESTIBULE 160 0 0.06 5 10 1720 FOR -ODE COMPLIANCE 'ROVED NOV 16 2015 "uicv ila 23SILDU6'G DIVISION 1 RECEIVED CITY OF TUKWILA NOV 0.3 2015 PERMIT CENTER B A PERKI N S +WILL 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 King County Library System 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions APERMIT SUBMISSION 10/16/2015 NO Job Number Drawn ISSUE DATE Sheet Information 161028.000 BG Checked Approved TM TM Title HVAC-WASHINGTON STATE ENERGY CODE FORMS Sheet MOI-OO ins+Will CV — SHEET NOTES PE R K I N S +WILL c A 2/26/2013 4:00:44 PM HVAC SITE PLAN NTS GLS GLR // / / 1" (TYP-8) 1 \ \ / / \ / / \ \ 2" 1" / / A. B. C. D. E. F. GLS/GLR TO BE BURIED 6FT BELOW FINISHED GRADE AND SHALL BE A REVERSE RETURN CONFIGURATION. EACH WELL SIZED FOR A MINIMUM OF 1.2 TONS (14.2 MBH) OF HEATING/COOLING CAPACITY. BORE HOLES SHALL GO ONLY IN AREAS DEEMED APPROPRIATE BY THE CIVIL AND STRUCTURAL ENGINEERS TO AVOID FOOTING AND SOIL PILES. BORE HOLES MUST REMAIN A MINIMUM OF 20'-0" APART FROM EACH OTHER. FINAL SIZING OF THE GEOTHERMAL SYSTEM SHALL BE BY THE CONTRACTOR. SIZE TO AVOID THERMAL DEGRADATION OVER 20 YEARS SO THE ANNUAL PERFORMANCE REMAINS CONSISTENT. THE BORE HOLE FLUID SIDE OF THE GEOTHERMAL LOOP SHALL BE WATER. SEE SHEET E01-02 FOR COORDINATION OF GLS/R WITH UNDERGROUND ELECTRICAL EQUIPMENT ROUTING. NUMBERED NOTES TEMPERATURE SENSOR LOCATED 15 FT MINIMUM BELOW GRADE. 2" GLS/R UP TO MECHANICAL MEZZANINE. • NOV 16 2015 Ci {' Oi i�E i CC Em , re �PIa€ ai4 �fOlLiiel RECEIVED CITY OF TUKWILA NOV 0 3 2015 PERMIT. CENTER 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 King County Library System 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Job Number Sheet Information 161028.000 Drawn BG Checked TM Approved TM Title HVAC SITE PLAN Sheet MOI-01 2012 Perkins+Will 5 4 3 2 CV PERKI N S +WILL 10/14/2015 3:37:53 PM u7 M m cn (`II C O LoI 0 N t 0 m (II co a 2 w U 0 tit 1- w .0 o U O Cr) O Cr) N B A 1 (Th RFM 2 RFM 1 RFM 4 RFM 8 RFM 3 • n ET T .................. . V v ) t c w <.e ) zar )( )( )•( �lfiZlFlYi3. l v w w w .-. ✓ v HVAC RADIANT FLOOR PLAN 111 • 1 ) ) ) (RFM 7 3/16" = 1'-0" SHEET NOTES: A. RADIANT FLOOR IN -SLAB PIPING TO ROUTE IN TOPPING SLAB. SEE SHEET A00-40 FOR FLOOR SECTION. B. COORDINATE FINAL RADIANT FLOOR LAYOUT WITH ELECTRICAL FLOOR DEVICES, SEE SHEET E02-01. C. COORDINATE FINAL RADIANT FLOOR LAYOUT WITH STRUCTURAL BRACE FRAME LOCATIONS. SEE SHEET S-201. D. SEE DETAIL 2/M05-02 FOR RADIANT FLOOR PIPING DETAIL NUMBERED NOTES: SEE DETAIL 4/M05-01 FOR RADIANT MANIFOLD PIPING DETAIL. IN -SLAB RADIANT FLOOR TEMPERATURE SENSOR. ONE FOR EACH ZONE. ROUTE RADIANT PIPING AROUND FLOOR DRAINS. ISOLATION VALVES FOR RADIANT MANIFOLDS LOCATED ABOVE HARDLID CEILING. RADIANT MANIFOLD TO BE COMPLETELY CONCEALED WITHIN WALL CAVITY. PROTECT RADIANT MANIFOLD FROM STORAGE MATERIALS WITH UNISTRUT INSTALLED IN FRONT OF MANIFOLD. ACCESS TO MANIFOLD FROM RESTROOM WALL. ACCESS TO MANIFOLD BELOW SINK. IE COMPLIANCE NOV 16 2015 City of BUILDING Dry_j'ISION • RECEIVED CITY OF TUKWILA NOV 0 3 2015 PERMIT CENTER B A 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 King County Library System 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Sheet Information Job Number 161028.000 Drawn BG Checked TM Approved TM Title HVAC RADIANT FLOOR PLAN Sheet M02-OO 5 4 3 2 1 N SHEET NOTES: 10/14/2015 3:37:56 PM Lri 0 CO f6 a) Ln O 0 U CO f0 .3 J Y 0 0 n. 2 in w -J LT- C.) O J w n_ Y Q 03 i> 0 E U 0 0 ro- N M O O y 0 0 B A EG-A CD-B, 40 (35) 2" HWS/R UP EG-B (100) 12x10 UP 10x10 UP 2" GLS/R UP CD-B, 40 (25) ER -A (50) CD-B (50) 26x4 UP SR -A, 6x6 (50) TYP-2 FCU 7 SR -A, 22x10 (600 ) TYP-2 RS/RL HVAC FLOOR PLAN - LEVEL 01 \1\ 3/16" =1'-0" '(600) TYP-2 24"4" ACCESS PANEL (TYP-2) RS/RL STDF -,F iC (250) TYP-2 16"x8" 3/4" HWS/R DN TO RFM 3 112 . „ty F ER-C, 12x8 (200) CD-B, 40 (25) 3/4" HWS/R DN TO RFM 2 1 1/2" HWS/R DN TO RFM 4 & 6 1" HWS/R DN TO RFM 1 RS/RL UP ER -A, 48x14 250 (TYP-2) EG-A <10 250 (TYP-2 1 1/4" HWS/R DN TO RFM 8 ER-C, 48x12 (1200) „ 111 ER-C, 24x10 (800) TYP-2 24"x24" PENETRATION FOR VAV ACCESS IN METAL DECK 8" o UP (SEE SHEET M02-02 FOR CONTINUATION) SR -A, 24x10 (800) 24X24 ACCESS PANEL 1" HWS/R DN TO RFM-5 1 1/4" HWS/R UP RL/RS UP 1" HWS/R DN TO RFM-7 TYP TYP \ 24X24 ACCESS PANEL CD-B (100) SR -A, 24x10 (700) MOUNT CO2 SENSOR 48" AFF. A. DIFFUSER AND GRILLES ARE ONLY GENERALLY LOCATED FOR FINAL LOCATIONS SEE ARCHITECTURAL DRAWINGS. B. NO ACCESS PANELS ALLOWED IN WOOD CEILING ABOVE MOSAIC AND MEETING ROOM. NUMBERED NOTES: ARCHITECT TO PROVIDE WINDOW OPERATOR AND WINDOW OPERATOR CONTROL UNIT. WINDOW CONTROLLER TO HAVE 24V CONTACT TO BE WIRED BY DIV 26 TO THE BMS SYSTEM. BMS CONTROL WINDOW OPERATION AND WILL TURN OFF FCU'S AND RADIANT FLOOR VALVES WHEN WINDOWS ARE OPEN. SEE ELECTRICAL DRAWINGS FOR POWER FOR WINDOW AND SKYLIGHT OPERATORS. ROUTE 3/4" CONDENSATE TO NEAREST SINK AIR GAP. SLOPE AT 1/8"-1'0". SEE DETAIL 1/M05-02. 1" HWS/R TAKE -OFFS FROM 2" MAINS TO ROUTE TO EACH RADIANT MANIFOLD. MOUNT T-STAT 60" AFF. PIPING CONCEALED IN WALL. COORDINATE LOCATION W/ STRUCTURAL BLDG FRAME. COORDINATE W/ PLUMBING WASTE & VENT. 3-WAY AUTOMATIC CONTROL VALVE. SLAB PENETRATION AT LEVEL 2. COORDINATE HWS/R PIPING WITH STORAGE ROOM DOORS. • PROVIDE REMOTE DAMPER ACTUATOR FOR DAMPERS IN HARDLID AND SOFFITS. SEE DETAIL 3/M05-02. NOV 16 2015 City of Tukiyiia UILD,i G{ DIVISION RECEIVED CITY OF TUKWILA NOV 0 3 2015 PERMIT CENTER B A PERKI N 5 +WILL 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 King County Library System • fr# 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Sheet Information Job Number 161028.000 Drawn BG Checked TM Approved TM Title HVAC FLOOR PLAN - LEVEL 01 Sheet M02-01 (V SHEET NOTES: 10/14/2015 3:37:58 PM Lri (NI N co O 0 2 a) U! U Y 1 r J U 0 0 a. 2 w J_ L U O 1- in 1 ( re/ .y E U O 0 Co— N Cr) O Cr) cn to 7 y L a) cn l U A —4 rt� 202 RL/RS (STACKED) HWS/R (STACKED) LD-A, 10x6 (200) TYP-4 fi`JI i�j, `v 6"x32" 8"x12" SOFFIT::::: HWS BEAM PENETRATIONS (TYP) 18"x6" HWR FCU 10 FCU 12 FCU 11 3/4 CD DN 1 1/4" HWS/R UP 28"x6" HWS LV NJ 7 CD HWR 4.6 7. /\I 20"x8t5) O 20"x6" (Id) O 36"x6" Lc r i 11 RL 36"x6" SR -A, 36x6 (1000) TYP-3 8"x10" LD-A, 2'-0" (50) TYP-4 RS 36"x6" :• • CD RL =8"w DN TO° LD-A, 2'-0" (130) TYP-7 36"x6" RS/RL DN HVAC FLOOR PLAN - LEVEL 02 \� 3/16" =1'-0" A. SEE DETAIL 1/M06-02 FOR REFRIGERANT PIPE SIZES. B. NO ACCESS PANELS ALLOWED IN WOOD CEILING AT MOSAIC AND MEETING ROOMS. C. ALL DUCTWORK TO BE CONCEALED IN CEILINGS, WALLS, OR SOFFITS. NUMBERED NOTES: ROUTE 3/4" CONDENSATE DN TO MEETING RM SINK AIR GAP. SEE DETAIL 1/M05-02 AND SLOPE AT 1/8" PER FOOT. 12X8 BEAM PENETRATION. CONFIRM FCU IS NOT INSTALLED ABOVE ELECTRICAL PANELS. SEE ELECTRICAL DRAWING E02-02. 24x24 RETURN AIR GRILLE PENETRATION AT METAL DECK. PROVIDE 24x24 PENETRATION AT METAL DECK FOR FOR FCU ACCESS FROM ABOVE. PROVIDE REMOTE CABLE DAMPER ACTUATOR. SEE DETAIL 3/M05-02. FIELD CUT RAW EGGCRATE TO FIT IN DUCT CONNECTION TO LD-A DIFFUSER FOR IMPROVED AIR FLOW. 7,1 NOV 16 2015 BUILDING DL_City of TuilgslatoN RECEIVED CITY OF TUKWIL,A NOV 0 3 2015 PERMIT, CENTER B A PERKI N S +WILL 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 King County Library System 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Job Number Sheet Information 161028.000 Drawn BG Checked TM Approved TM Title HVAC FLOOR PLAN - LEVEL 02 Sheet M02-02 CV — 5 PERKI N S +WILL c B A 10/14/2015 3:37:59 PM SHEET NOTES: A. ABC NUMBERED NOTES: NOT USED PROVIDE WINDOW CONTACT BUILT INTO THE WINDOW FRAME TO ALLOW FOR CONTROL BY THE BMS TO TURN OFF FCU'S AND RADIANT FLOOR VALVES WHEN OPERABLE SKYLIGHTS ARE OPEN. � � N C .. .v 'w!/a..a s' a NOV 16 2015 City a Q r a t�l�o? u �arri i`�' �I �fI�. DING u RECEIVED CITY OF TUKWILA NOV 0 3 2015 PERMIT. CENTER HVAC ROOF PLAN 1 3116" =11-0" c A 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 King County Library System 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Sheet Information Job Number 161028.000 Drawn BG Checked TM Approved TM Title HVAC ROOF PLAN Sheet M02-03 5 4 3 2 1 CV — PERKINS +WILL 10/14/2015 3:38:00 PM N co O 0 CO E. 4) UI 0 N t 0 7 f'- 0 0 a 2 6 w LT_ J U O J w a_ Y U m W U O 0 6 N N M O U c A 3'x2' ACCESS PANEL INSULATED SHEET PLENUM TO SEPARATE LOUVER FROM MECHANICAL ROOM SHEET METAL DUCT UP TO RELIEF HOOD ASHP 3'x2' ACCESS PANEL 3 03-0 20x14 MAKE-UP AIR DAMPER 5 1-77 16"x16" 34"x30" 20"x12" 1" ACOUSTICAL LINING • • I I L— PLUMBING AND FIRE PROTECTION IN THIS AREA. HVAC ENLARGED PLAN - LEVEL 02 1/2" = 1'-0" 20x12 CONNECTION TO EXHAUST PLENUM 5\ r — i M05-02 L RS �`X% /-; %• • RL r —H I I 2" ACOUSTICAL LINING ri J 34x18 SLAB PENETRATION 5 (BIC M05-01 (TYP FOR ALL PUMPS) 4 UU RS/RL (STACKED) HWS/HWR (STACKED) 8"x12" L _ — L — — 0 0 (j) n 00 20"x12" RL/RS DN 2" HWS/R AND RL/RS DN 2" GLS/R DN 34x18 EXHAUST / SUPPLY UP/DOWN BMS & MITSUBISHI CONTOL MODULES VFD'S FOR PUMPS CP-1,2 & 3 2 WATER TREATMENT 3 30"x10' ER -A, 30x10 (1300) 2 MOUNT ON NEOPRENE PAD AND USE A WASHER GROMMET USED AT THE BOLT CONNECTIONS TO STRUCTURE. PROVIDE COMPRESSOR BLANKET. 8"X8" HOIST FOR MECHANICAL ROOM MAINTENANCE. SEE SHEET P03-01 FOR MAKE-UP WATER CONNECTION FOR HW AND CW. ROUTE CONDENSATE AND DRAIN LINES TO FLOOR DRAIN. NOV 1 2015 r p 7,t I 1 a ®.DING Di‘. RECEIVED CITY OF TUKWILA NOV 0.3 2015 PERMIT CENTER 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 King County Library System 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Sheet Information Job Number 161028.000 Drawn Author Checked Checker Approved Approver Title HVAC ENLARGED PLANS & SECIONS Sheet SHEET NOTES: A. PROVIDE 4" CONCRETE CURB FOR ASHP-1, WSHP-1 AND AHU-1. NUMBERED NOTES: 1 cV — PERKI N S +WILL B A 10/14/2015 3:52:38 PM RH INTAKE PLENUM OHVAC SECTION - C 1/2" = 1'-0" EXHAUST PLENUM RS/RL ASHP ji LEVEL 02 307' - 10" OHVAC SECTION - B 1/2" = 1'-0" HVAC SECTION - A 1/2" = 1'-0" 20"x6" EG-A, 24x24 TO BRANCH CONTROLER ASHP 1 0 DO t • 0 0 DO 1 I O it U \ ! I CD-B, 40 (100) 0 16"x8" 12"x20" F'�, eIvv i I "! V / i I v' I': i I . —I • I <AHU> 1 CD-B, 40 (35) LCN RL/RS T.O. ROOF - EAST 320'-71/2" 8"x16" B SILL @ CLERESTORILftik 312'-8" NOV 16 20`I5 City a an = I i!aril la iLDIN(.3 r ,1 ti A RECEIVED CITY OF TUKWILA NOV 0 3 2015 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 King County Library System )40„41/IN 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Sheet Information Job Number 161028.000 Drawn Author Checked Checker , Approved Approver Title PERMIT CENTER 1 HVAC SECTIONS LEVEL 01 297'-6" Sheet M03-02 5 4 3 I 2 I 1 N PERKIS ±WI LL c B A 2/26/2013 4:00:44 PM /ET \ /ASHP\ 01 288 MBH BC-1 HX-1 HX-2 () RS/RL LINES TO FAN COILS (TYP-13) WSHP-01 120 MBH WSHP 01 4" 2" ez--- /////////////// GROUND LOOP L HVAC HYDRONIC DIAGRAM NTS 1405-0 CWS CWR 11 HWS HWS AHU 01 HC 11 2" HWS/R TO RADIANT FLOOR MANIFOLDS COMPLIANCE ,d P L .. r 7E 7,1 NOVI 205 BUILDING Dv°n ON a RECEIVED CITY OF TUKWILA NOV 0'3 2015 PERMIT CENTER RADIANT FLOOR MANIFOLDS (TYP-8) 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 ing County Library System 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Job Number Drawn BG Checked TM Approved TM Title HVAC HYDRONIC DIAGRAM Sheet 12 Perkins+Will 5 4 3 1 2 1 CV - PERKI N S +WILL N B A 2/26/2013 4:00:44 PM °Y" LATERAL FITTING DRAW BAND WORM -DRIVE HW PIPING AND CW PIPING S OVAL TO ROUND TRANSITION BALANCING DAMPER MAIN SUPPLY DUCT ROUND CONNECTION WITH 3/8" RAISED BEAD SAME DIAMETER AS FLEX CONNECTION. MAIN ROUND DUCT ! 314" SUPPLY HEADER MOTORIZED VALVE ACTUATOR WIRED TO RELIEF AIR THERMOSTAT PER ZONE. VENT (TYP) WALL MOUNTED THERMOSTAT IN ZONE. ONENY -� 45° ROLL WYE TOWARD SLOT INLET NECK FLEXIBLE DUCT TO DIFFUSER 4, I j i BALANCING VALVES CAP 6"MAX _ I NC ; NC BALANCING DAMPER IP ROUND DUCT COLLAR WITH 318" RAISED BEAD AND BALANCING DAMPER ROUND TAP TO ROUND MAIN FLAT EQUIVALENT - OVAL, SEE SCHEDULE FOR FLEXIBLE DUCT TO TO ROUND SIZE DIFFUSER- SHUT OFF VALVES S 1 ®® �� ® ■ r C j RETURN HEADER = Al- = NC UNION (TYP) ISOLATION VALVE FLAT OVAL EQUIVALENT ROUND ! a.;:. E— -W' - 30"MAX ROUND 0 FLAT OVAL INCHES PEX TUBING ii t �of , j ,� ...) 6 4x9 I 314 TO FLOOR DRAIN PIPE SHIELD i �' 7" 5x10 FLOOR 8" 6x11 NOTES: COVERING .a_ m .. -.._ ._ //; __..: �.:.:,m, 10" 6x11 FLEXIBLE DUCT TO DIFFUSER MAIN DUCT SPIN-IN ROUND COLLAR WITH 318" RAISED BEAD & BALANCING DAMPER ROUND TAP TO RECTANGULAR MAIN o e/ 12" 7x20 ������������������i 1. PROVIDE 5 GALLON POT FEEDER FOR HEATING WATER SYSTEM 2. PROVIDE 5 GALLON POT FEEDER FOR CONDENSER WATER SYSTEM 14" 8x22 16" 8x30 FRONT VIEW SIDE VIEW ROUND TAP TO RECTANGULAR MAIN (TAP LARGER THAN MAIN) (TAP SMALLER THAN MAIN) LOW PRESSURE BRANCH DUCT CONNECTIONS RADIANT FLOOR MANIFOLD CHEMICAL POT FEEDER DETAIL CONDENSER WATER AND HEATING WATER LOOPS NONE - NONE NONE THREADED HANGER 1" LINE -PIPE TO NEAREST FLOOR DRAIN LAPPED AND COMPRESSED SEE DETAIL "B" STEEL OR ROD(4) TO SUPPORT WEIGHT OF PUMP, MOTOR AND SUPPORTS ATTACH TO STRUCTURE LINER ADHERED TO THE DUCT WITH 100% COVERAGE OF ADHESIVE PIPE HANGERS TO t SUPPORT PIPE AND SPRING VIBRATION ISOLATOR TYPE MASON INDUSTRIES 30N VALVING PIPE AND (WEIGHT OF VALVES CORNER BREAK AUTOMATIC AIR FROM PUMP DISCHARGE OR TERMINAL UNIT ENTERING SIDE VENT '*RF `0� LONGITUDINAL '� Ii"I""';I' '������'%� I 6" 6" '' /I ROD NOT TO PUMP BE ON CASING) I HANGER RODS HANGER ECCENTRIC REDUCER ECCENTRIC INCREASER FITTING �� JOINT - a BAND HANGER INSULATION CONTINUES AT ALL SUPPORTS FITTING 1 STRAINER 3/4° BLOW --OFF HOSE END PRESSURE/TEMP. FITTING(TYP) CHECK TEST VALVE DUCT NOTES: jj jjj jj jjjj jjjjljjjjj jlj ►, 18" j►. j�►/' ., �/�1` 3" 1 .li " IIII� MECHANICAL WITH WASHER - 6" SELF-LOCKING 6" ill l' 6 " FASTENER ., 0" "4" 16 3 6 " AIR SEPARATO' 4 " PIPE 4" LONG x 16VALVE SHUTOFF VALVE _ CALIBRATED BALANCE VALVE TO PUMP SUCTION OR TERMINAL UNIT BALANCING VALVE �� ���a A ` GAUGE SHIELD �% / ADJUSTABLE SOCKET LONG FULL SECTION OF CALCIUM UNION 1 -H- 1 I ."n 1_ LEAVING SIDE 1 BLOW DOWN, RUN TO O p i -- I-, _471 L SILICATE WITH VAPOR BARRIER EXTENDED 2" OVER EACH END b ; > // S _ _ -= �- _ - -_ r ~ 'L- r - - - PUMP SUCTION PUMP DISCHARGE 1. MECHANICAL FASTENERS ARE TO BE SPOT WELDED TO DUCTWORK. 2. PROVIDE SHEET METAL NOSING AS DESCRIBED IN SPECIFICATIONS. CLAMP NEAREST FLOOR DRAT NEOPRENE WAFFLE PAD (TYP) STEEL SUPPORTS, SEISMICALLY BRACED 0 TYPICAL HOT WATER AND REFRIGERANT PIPE HANGER 0 IN -LINE PUMP DETAIL 0 AIR SEPARATOR DETAIL ACOUSTIC DUCT LINER - NONE - NONE0 - NONE (SINGLE AND MULTIPLE PIPES) NONE p`R aE 1 I,A E !f 3 O R DE a s��.-1 �e PL1ANCE NOV16 2015 City of Tukwila `BUIL3�. 1i$,sC e�ss@t�I�eCS� K, RECEIVED CITY OF TUKWILA NOV 0 3 2015 PERMIT. CENTER 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 King County Library System 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Sheet Information Job Number 161028.000 Drawn BG Checked TM Approved TM Title HVAC DETAILS Sheet 05=01 rkins+Will 5 4 I 3 1 2 1 1 PERKI N S +WILL B A 2/26/2013 4:00:44 PM TYPE III SEISMIC AIRCRAFT CABLE REFER TO SPECIFICATION BOX CONCRETE TOPPING SLAB ELECTRICAL CONNECTION ACOUSTICALLY LINED PLENUM FLEX CONNECTION WIRE TIE NOTE 4 SPRING VIBRATION ISOLATOR TYPE • MASON INDUSTRIES n 4/1 30N Ili • ..-V'•,7 — —*Pr HANGER ROD MAX. 1 / ���; \ 41,/ SLAB ON GRADE `� '''W 41111 MIXING BOX ! vow. SUSPENDED. EQUIPMENT • - DUAL U-BOLT RETURN AIR OPENING -� a. , �i� ��� CABLE CLAMPS , 1 1 ' ABLE EYELET C REFRIGERANT PIPING (INSULATED) _ TAB DAMPER DUCTWORK TO BE' ��� INSULATION 1 WIRE MESH, REBAR OR " LOCK NUT CONDENSATE PUMP 118 ANGLE BELOW DRAIN LINE AND WASHER (IN APPLICABLE) NOTES: TUBING STAPLE TO RIGID FOAM CONDENSATE _ PIPING (INSULATED) `1 TAB ,�\)))1 FOR IF ADEQUATELY SUPPORTED ACOUSTICALLY LINED PLENUM DAMPER BRANCH DUCT APPLICABLE NOTES: 1. HANGER SPACING ALONG LENGTH OF UNIT TO BE AS FOLLOWS: MINIMUM -2 HANGERS MAXIMUM SPACING 6'-0" 2. PROVIDE ADEQUATE SEISMIC CABLE BRACING TO RESIST MOTION IN ALL LATERAL DIRECTIONS 3. REFER TO SMACNA SEISMIC RESTRAINT MANUAL GUIDELINES (LATEST EDITION) FOR MECHANICAL SYSTEMS. 4. ATTACHED TO STRUCTURE ABOVE. 1. STRUCTURAL ELEMENTS SHOWN FOR REFERENCE ONLY. 6 SUSPENDED EQUIPMENT WITH 4 INDOOR VRF FAN COIL UNIT 0 RADIANT TUBING INSTALLATION CONCRETE TOPPING SLAB NONE NONE SEISMIC CABLES NONE WATER TO WATER 2-WAY HWR MAIN STAINLESS WIRE. 50 FEET MAXIMUM 0 r CEILING AIR GAP FITTING �� N 1"CONDENSATE DRAIN FROM MECHANICAL NIT OR CONDENSATE PUMP. VENT MAIN HEAT PUMP UNIT PRESSURE xxxxxxxxxxx "xxxx DUCT • AND (WSHP-1) CONTROL VALVE TEMPERATURE PORT (TYP) GROUND LOOP (TYP) RETURN 64 LOCKING GEAR DRIVE i _ CONTROLLER KIT kl • MANUAL AIR VENT AUTOMATIC FLOW CONTROL HOSE KIT W OR CHW MAIN SEE SPECS 6 0.1 AIR � \ C _ C „ � • AUTOMATIC VALVE (BY SHUTOFF VALVE CONTROL DDC CONTRACTOR) ►IPH EXTERNAL CONTROLLED COLLAR • REMOTE CONTROLLER a VOLUME DAMPER AT MAIN DUCT CONNECTION NW �Q� . �I— —II GROUND LOOP u SUPPLY BRANCH DUCT WITH SIX FEET OF ONE INCH ACOUSTICAL LINING NOTES: INACCESSIBLE SUSPENDED CEILING DIFFUSER SINK _i HOSE y } ,,- x m R c N o 1. CONTROLLER INSTALLED INSIDE PLENUM AND THE DIFFUSER FRAME. ADJUSTED THROUGH —II HYDRONIC COIL -w" HOSE END C TEMPERATURE -PRESSURE TEST FITTING (TYP) � HWR . / I —I --0 4 C / / CONTROL VALVE (TYP-2) �I— u 3 HOSE -ENDED DRAIN VALVE WI CAP (TYP) 6" DIRT LEG MAIN DUCT INSULATED o STAINLESS WIRE. 50 FEET MAXIMUM P-TRAP o .,,,,, ,.,.,1..._ � FLOOR DRAIN VALVE WITH UNION (CLEAR OF COIL REMOVAL SPACE) EXTERNAL CONTROLLED LOCKING GEAR DRIVE CONTROLLER KIT MOUNTED ON NOTE: CAP AND CHAIN NOTES: VOLUME DAMPER / TOP OF DIFFUSER O .- (np) SHUT-OFF VALVE - TYPICAL NOTES: 1. COMBINE DRAIN CONNECTIONS AT EACH SINK. 1. ALL BRANCH PIPING, SUPPLY, RETURN AND VERTICAL HEADERS TO BE FULL SIZE BOTTOM CONNECTION FROM MAIN. (REFER TO DRAWINGS FOR PIPE SIZE) 2. ALL HORIZONTAL CONNECTIONS TO COIL FROM VERTICAL HEADERS TO BE SIZE OF COIL CONNECTION OUTLET/INLET. 3. AT AIR TERMINAL UNITS WITH INTEGRAL COIL; MANUAL AIR VENT CAN BE LOCATED AT THE COIL OUTLET PIPING, AND DRAIN VALVE AND CAP CAN BE LOCATED AT THE COIL INLET PIPING. OMIT DIRT LEG. / __________________:,__V NOTES: INACCESSIBLE SUSPENDED CEILING 1. CONTROLLER INSTALLED ON TOP OF DIFFUSER AND REMOTE CONTROLLER ADJUSTED THROUGH LAY -IN CEILING DIFFUSER FRAME. DIFFUSER 1. REFER TO RISER DIAGRAM FOR PIPE SIZES. 2. ALL PIPING TO BE CLEAR OF SERVICE AND ACCESS CLEARANCE. 0 WATER TO WATER HEAT PUMP CONNECTIONS 11111 HYDRONIC HEATING COIL PIPING 11111 REMOTE CABLE DAMPER CONTROLLER �' CONDENSATE DRAIN CONNECTION • TO SINK AIR GAP FITTING NONE NONE (2-WAY CONTROL VALVE) AHU-1 NONE DETAIL (WSHP-1) NONE 4 .m e . F..a r-a F- 01 EE COMP LANCE NOV 1 G 2015 CI'_y of Tukwila SUP DING a• i- Ais RECEIVED CITY OF TUKWILA NOV 0 3 2015 PERMIT CENTER 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 King County Library System 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Sheet Information Job Number 161028.000 Drawn BG Checked TM Approved TM Title HVAC DETAILS Sheet O5O2 5 4 3 2 1 PERKI NS +WI LL B 2/26/2013 4:00:44 PM GRID SUSPENSION SYS CJ COORDINATE EXACT DIFFUSER LOCATION WITH WOOD SLOT VOID AS SPECIFIED BY ARCHITECTURAL DRAWINGS — EQ 77SECURE PLENUM DIFFUSER PLENUM —/\/\:_______--- FLEX CON DUCT COL E 2.75" lJ NECTION LAR WD CEILING SYS TITUS BORDER TYPE 11 OR EQUAL PAINT MAT BLACK WOOD SLAT CEILING LINEAR DIFFUSER DETAIL NONE 4 175-071 O H 0 H Q ' I u HX-1 S REFRIGERANT PIPING BACK TO BC-1 CONDENSATE DRAIN PIPE ROUTE TO NEAREST FLOOR DRAIN AAV(LARGE CAPACITY) AIR SEPARATOR REDUCE TO SIZE OF AIR SEPARATOR NOTE 3 FULL SIZE T OFF TOP OF MAIN D4 \ COLD /WATER BACKFLOW PREVENTER DRAIN OUT VALVE WITH HOSE BIBB SEE NOTE 2 MAKE-UP SIZE (d) TOTAL SYSTEM PUMP FLOW(GPM) d (IN.) PRV MIN. FLOW (GPM) UP TO 200 1/2 3 P.O.S. NOTES: 1 4 N.C. III D4 III 20-1 t Ix Ns. I I--�B�—III I Ca MAKE-UP PRV PRESSURE RELIEF VALVE SEE NOTE 1 TO PUMP SUCTION AAV 1 FLOOR MOUNTED — DIAPHRAGM EXPANSION TANK FLOOR 1. CONNECT TO SIDE OF MAIN TO PREVENT AIR OR DEBRIS FROM ENTERING PIPE TO TANK. TOP OR BOTTOM CONNECTION NOT PERMITTED. 2. PROVIDE ANTI-THERMOSYPHON LOOP TO PREVENT GRAVITY HEATING OF TANK. 3. FROM WSHP HX UNIT PIPING DETAIL NONE MAKE-UP WATER, EXPANSION TANK AND AIR SEPARATOR DETAIL NONE 5 1 4 3 2 1 A O �D'E� NOV 1 6 2015 City of Tukwila RECEIVED CITY OF TUKWILA NOV 0.3 2015 PERMIT. CENTER 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 ing County Library System 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Job Number Drawn Checked Approved BG TM TM Title HVAC DETAILS Sheet - PERKINS +WILL B A 2/26/2013 4:00:44 PM ALARM (CRITICAL) FIRE ALARM LIGHTING CONTROL PANEL OPERABLE WINDOWS AND SKYLIGHTS REFRIG MONITOR INSIDE BUILDING NUMBERED NOTES REFRIGERANT LEVEL (PPM) ALARM (SUPERVISORY) POWER BMS CONTRACTOR SHALL BRING WIRES FROM BMS PANEL TO THE THIRD PARTY DEVICE. INSTALL INTERPOSING RELAYS TO AVOID VOLTAGE AND GROUND LOOPS. OUTSIDE BUILDING BUILDING STATIC PRESSURE OUTSIDE AIR TEMPERATURE OUTSIDE AIR CO2 OPERABLE WINDOW SW NUMBERED NOTES WINDOW OPERATOR AND WINDOW OPERATOR CONTROL UNIT PROVIDED BY DIV 08. DIV 23 TO CONNECT TO AVAILABLE 24V CONNECTION(S) TO BMS SYSTEM. ARCHITECT TO CONFIRM THAT SYSTEM IS LONWORKS COMPATIBLE. MITSUBISHI INTERFACE (BAC—HD1 50) VRF CONTROLLER TO VRF CONTROL NETWORK (HEAT PUMPS, ERVS, HEAT EXCHANGERS) NUMBERED NOTES PROVIDE INTEGRATION BETWEEN THE VRF CONTROLLER AND THE BMS SYSEM TO ALLOW READ/WRITE OF ALL AVAILABLE POINTS AND PARAMETERS. LOCKOUT LOCAL TEMPERATURE ADJUSTMENT FOR ALL THERMOSTATS PER KCLS REQUIREMENT. —�— HWS 5---�— HWR ROOM TEMPERATURE SENSOR 24VAC MANIFOLD PRIMARY HOT WATER SYSTEM MANIFOLD TO FLOOR LOOPS TO FLOOR LOOPS IIJ • SLAB TEMP ONE PER ZONE NUMBERED NOTES PROVIDE SLAB TEMPERATURE SENSOR FOR MONITORING PURPOSES TO MAINTAIN CONSISTENT APPEARANCE, ALL TEMPERATURE SENSORS PROVIDED BY CONTROLS CONTRACTOR, NOT VRF MANUFACTURER. MISCELLANEOUS BMS POINTS NONE OPERABLE WINDOW MONITORING TYP. PER EACH OPERABLE WINDOW AND SKYLIGHT NONE VRF CONTROLLER TO BMS INTEGRATION NONE TYPICAL RADIANT FLOOR MANIFOLD NONE 0 0 HX-1 HX-2 S VRF CONTROL NETWORK 0 S VRF CONTROL NETWORK co FLOW METER NUMBERED NOTES NETWORK CONNECTION SHALL ALLOW THE BMS TO ACCESS ALL AVAILABLE POINTS IN VFD. INTERLOCK HX OPERATION WITH PUMP OPERATION. HX SHALL NOT TURN ON UNTIL PUMPS ARE RUNNING. VFD CONTROL PANEL 0 I11 I s/s SPEED VFD CONTROL PANEL s/S SPEED BMS NETWORK 24VAC �— AB A TO RADIANT FLOOR S S OA 24VAC 24VAC NETWORK r DP FINAL FILTERS (TYP)'b- CS BY BMS DIV. 26 MIS BY OA FLOW NUMBERED NOTES VALVE PROVIDED BY AHU SUPPLIER, MOUNTED AND WIRED BY BMS CONTRACTOR. PROVIDE ROTATION SENSOR AND DIRTY FILTER SENSOR BMS POINTS. ALL 24V CONTROL WIRING TO BE PROVIDED BY MECHANICAL CONTROLS CONTRACTOR lil 0_ FTT • HEAT WHEEL 40) DP EA TEMP. ri FILTERS SMOKE DETECTOR u u DIVISION 26 115VAC BY 24VAC HWR FREEZE STAT A HWS DUCT STATIC PRESSURE (AT AHU) SA TEMP. 6TWO\NORK n HIGH STATIC n PRESSURE (AT AHU) SP EA DUCT STATIC PRESSURE (213 DOWNSTREAM) SA AHU-1 100% OUTDOOR AIR WITH HEAT RECOVERY NONE HYDRONIC HEATING SYSTEM - MEZZANINE Ra ; $ s'r. f •"'.;? RE, L�L'y .d FOR I: R COMPLIANCE NOV 16 2015 a City of T19kvi a 3U LDING 4D1V1S^c RECEIVED CITY OF TUKWILA NOV 0 3 2015 PERMIT CENTER B A NONE 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library 14242 Tukwila International Boulevard Tukwila, WA 98168 King County Library System 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Sheet Information Job Number 161028.000 Drawn BG Checked TM Approved TM Title HVAC CONTROL DIAGRAMS Sheet 06=01 ght © 2012 Perkins+Will 5 CV — PERKI S LL c B A DAGRAV SYVBOL H=G-\D DSDLAY 9-SCRDTO\ 1/1 DOW-R W R- CO\TROL W R- 1) D_ DDI\G L_ST SYW_OE EVA\C- 'IDE vIOIL \AVE J1 ecucer SYV OL NA RIPE/GAS PIPE SIZE D1 3/8 / 5/8 P2 1/4 / 1/2 D3 3/8 / 3/4 1-1/8 / 1-3/8 P5 7/8 / D6 / 1-1/8 D7 1/L / 1/2 Jo s<2C1 L MAP03 TB21 TB2 TB1 AC208N230V (50/60Hz) AG— 750A DAC-SC51 24VDC <„A 16-2 AWG(S) 3— 208-230V/6C F „ S /// System 1 "„RY— "288TSKv1.—A N 208-231V JsE 3— 208-230V/60 16-2 AWG(S) 16-2 AWG(S) F,S L1L2L3 D TB7 �Y—'144T�M�—A 052 P6 TB3 G FT- 1 P4 L1L2L3 P,TY—.3144T 051 TB3 c'(1 P6 QP CM 3—P1016.\ J—HA TB7 T Fueclioo 915 ON for Nigh Meg performeoce mode 2C8-23DV FUSE (s) 10 100-2LOV 2cor e P1 28-230V L1 L21 G 001 TB5 TB15 M 1 M2 053 L1 L2 1 ¶ T 2 J1 J1 J1 FJSE Gp1 / PEFY- P24NMAU-E2 16-2 AWG P1 G 7 8 9 10 11 12 13 14 15 16 L- L L J1 J1 v L L EF-1 CSR Q� NUMBERED NOTES DAMPER END SWITCH SHALL BE SEPARATE FROM ACTUATOR. ALL WIRING AND COMPONENTS BY BMS CONTROL CONTRACTOR STAGE 1 — CLOSED STAGE 2 - 50% OPEN STAGE 3 - 100% OPEN EF-1 EMERGENCY REFRIGERANT PURGE FOR EF-1 LOC: NEAR MECHANICAL ROOM DOOR 3-STAGE MAKE-UP AIR DAMPER EXHAUST FAN CONTROL DIAGRAM NONE System 2 D v Y Al2\1 L L L L L_ 218-230V L1 L2d G 002 TB5 TB15 S F SE Gp2 PEFY- P24NMAU-E2 1 IP2 IN 2d8 230V FUSE L1 L21 G 003 TB5 TB15 Gp3 PMFY- PO6NBMU-E 1 IP2 72 8 L L21 G 004 TB5 TB15 230V FUSE Gp4 PEFY- P15NMAU-E2 IP2 IN 208-230V L1L2 G 005 TB5 TB15 FJSE Gp5 PEFY- P15NMAU-E2 IP2 IN I 208-230V FUSE L1L2 G 006 TB5 TB15 Gp6 PEFY- P15NMAU-E2 P2 208-230V FUSE L1 L1 G 007 TB5 TB15 Gp7 PEFY- P15NMAU-E2 P2 2d8-230V L L21 G 008 TB5 TB15 F JSE Gp8 PMFY- P12NBMU-E P1 218-230V FUSE L1 L21 G 009 TB5 TB15 Gp9 PWFY- P36NMU-E-AU P3 218-23CV FUSE L1L2 G 01 0 TB5 TB15 Gp10 PWFY- P72NMU-E-AU P1 N 2d8-23oV FUSE L1 L21 G 01 1 TB5 TB15 Gp11 PEFY- P54NMAU-E2 1 P1 218-230V FUSE L1 L4 G 01 2 TB5 TB15 PEFY- P54NMAU-E2 Gp12 2 P1 823DV 1 FUSE L1 L21 G 013 TB5 TB15 Gp13 PEFY- P54NMAU-E2 P1 L1L24 G 01 4 TB5 TB15 Gp14 PEFY- P24NMAU-E2 FCU-1 FCU-2 FCU-3 FCU-4 FCU-5 FCU-6 FCU-7 FCU-13 FCU-9 FCU-10 , i FCU-11 FCU-12 Al P7 PKA— Al2HAL MRCH1 FCU-8 REViF:\AED FOR CODE COMPLIANCE q� BG 'NOV 16 2015 City of Tue,zwila BULLING DIVIcS. iC_LiH 1221 Second Avenue Suite 200 Seattle, WA 98101 t 206.381.6000 f 206.441.4981 www.perkinswill.com Tukwila Library D 14242 Tukwila International Boulevard Tukwila, WA 98168 RECEIVED CITY OF TUKWILA NOV 0 3 2015 B A ing County Library System 600 University St., Suite 500 Seattle, WA 98101 (206) 342-9900 www.wspgroup.com/usa PERMIT SUBMISSION 10/16/2015 ISSUE FOR BID 4/15/2015 Drawing Issue Date Revisions NO ISSUE DATE Sheet Information Job Number 161028.000 Drawn BG Checked TM Approved TM Title HVAC CONTROL DIAGRAMS Sheet 2/26/2013 4:00:44 PM VRF REFRIGERANT PIPING AND WIRING DIAGRAM PERMIT CENTER ght ©2012 Perkins+Will