HomeMy WebLinkAboutPermit M15-0151 - TUKWILA COMMERCE CENTER - AIR CONDITIONING UNITTUKWILA COMMERCE CENTER 846 INDUSTRY DR EXPIRED 05/16/16 M15-0151 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2523049015 Permit Number: M15-0151 846 INDUSTRY DR Project Name: TUKWILA COMMERCE CENTER Issue Date: 11/18/2015 Permit Expires On: 5/16/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: ICON TUKWILA OWNER POOL 2 L 2 N RIVERSIDE 2350 , CHICAGO, WA, 60606 MARK SMELTZER 1012 CENTRAL AVE S , KENT, WA, 98032 PERFORMANCE HEATING & A/C INC 1012 CENTRAL AVE S , KENT, WA, 98032 PERFOHA150RT Phone: (425) 251-0356 Phone: (425) 251-0356 Expiration Date: 4/30/2017 DESCRIPTION OF WORK: REPLACE FAILING 2 TON SPLIT AC SYSTEM WITH LIKE FOR LIKE UNIT. RECONNECT NEW UNIT TO EXISTING AIR DISTRIBUTION SYSTEM, POWER SUPPLY AND UTILITIES Valuation of Work: $11,600.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $350.42 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: J1t41ZJ1' 1t1J)1't,tI Date: ii/i /11:;- I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. n Signature: Print Name: Date: / /43//3-- This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 1800 0609 0705 0701 MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit issued by the City of Tukwila the job site at the time of inspection. CITY OF TUKWA_ . Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. I't 1�.016I Project No. Date Application Accepted: Date Application Expires: 10 l� (For office use on t) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: 846 Industry Dr, Tukwila Tukwila Commerce Center PROPERTY OWNER Name: ICON TUKWILA OWNER POOL 2 L54991th Address: 2 N RIVERSIDE 2350 City: CHICAGO State: II., Zip: 60606 CONTACT PERSON — person receiving all project communication Name: Mark Smeltzer Address: 1012 Central Ave S City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: (253) 867-5775 Email: mark@pmghvac.com King Co Assessor's Tax No.: 2523049015 Suite Number: Floor: 1st New Tenant: ❑ Yes ❑✓ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Performance Mechanical Group Address: 1012 Central Ave S City: Kent State: WA Zip: 98445 Phone: (425) 251-0356 Fax: (253) 867-5775 Contr Reg No.: PERFOHA15ORT Exp Date: 04/30/2017 Tukwila Business License No.: Valuation of project (contractor's bid price): $ 11,600 Describe the scope of work in detail: Replace failing 2 ton split-ac system with like -for -like unit. Reconnect new unit to existing air distribution system, power supply and utilities. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑✓ Replacement Fuel Type: Electric ❑✓ Gas ❑ Other: H:\Applications\Forms-Applications On Line \2011 Applications \Mechanical Permit Application Revised 8-9-I l.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <l OOk btu Furnace >l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfin 1 Unit Type Qty Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER ORUIOR D AG�'j(/� Signature: lr Date: 11/06/2015 Print Name: Mark Smeltzer Day Telephone: Mailing Address: 1012 Central Ave S Kent WA 98032 City State Zip H:\Applications\Forms-Applications On Line \20I 1 Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY I PAID $350.42 M15-0151 Address: 846 INDUSTRY DR Apn: 2523049015 $350.42 MECHANICAL $336.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $237.05 PLAN CHECK FEE R000.322.102.00.00 0.00 $67.39 TECHNOLOGY FEE $13.48 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6602 R000.322.900.04.00 0.00 $13.48 $350.42 Date Paid: Friday, November 06, 2015 Paid By: SHIRLEY FEWW Pay Method: CREDIT CARD 065132 Printed: Friday, November 06, 2015 4:10 PM 1 of 1 OrPPKYSTEMS TRANE® Performance Mechanical Group TAG: TCC Bldg 20 NOTE: All dimensions are in mm/inches. HP-1 SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED 50 ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12'I FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. ELECTRICAL SERVICE - PANEL 22.2 (1/81 DIA. HOLE LOW VOLTAGE 28.6 (1-I/81 DI N.O. WIT 22.2 11/8) DI, HOLE IN CONTRO 80X BOTTOM FOR ELECTRICA POWER SUPPL LIOUID LINE SERVICE 'E' I.D. FEMALE BRA CONNECTION WITH I/4 FLARE PRESSURE TAP FITTINGS. RECEiVE CITY OF TUK NOV 0 5 201 PERMIT CENTER 60-2 4 25 III lW1�Ws 1♦��.f W4E. III ...... Iill liril i uii iiwIMIIM iwii VALVE. ZE,,, J N.O. FOR ALTERNATE( (CTRICAL 1 I A5 LINE 1/4 TURN BALL SERVICE VALVE, 'D' r I.D. FEMALE BRAZED CONNECTION WITH I/4' SAE FLARE PRESSURE TAP FITTING. LIOUID LINE SERVICE VALVE, 'E" I.O. FEMALE BRAZED CONNECTION WITH I/4' SAE FLARE PRESSURE TAP FITTING. AS LINE SERVICE VALVE, '0' I.D. FEMALE BRAZED CONNECTION WITH 1/4' SAE FLARE PRESSURE TAP FITTING. OUTING From Dwg. D156010 MODELS BASE A B C D E F G H J K 4TWR5024G 3 832 829 756 5/8 3/8 143 92 210 79 508 (32-3/4) (32-5/8) (29-3/4) (5-5/8) (3.5/8) (8-1/4) (3-1/8) (20) 4TWR5024-SUB-101.00 SUBMITTAL 2 Ton Split System Heat Pump —1 Phase F IL 13 4TWR5024G Product Specifications OUTDOOR UNIT ®® 4TWR5024G1000A POWER CONNS. — V/PH/HZ ® MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS) COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS ® - L.R. AMPS FACTORY INSTALLED START COMPONENTS INSULATION/SOUND BLANKET COMPRESSOR HEAT 208/230/1/60 11 15 CLIMATUFF® 1-1 208/230/1/60 8.3 - 58 YES NO YES OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS PROPELLER 23-1 DIRECT - 1 2650 1-1/8 825 200/230/1/60 .74 OUTDOOR COIL — TYPE ROWS-F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT LBS. — R-410A (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ. SPINE FINTM 1 - 24 18.75 3/8 7 LBS. - 2 OZ. YES 5/8 3/8 CHARGING SPECIFICATION SUBCOOLING 8°F DIMENSIONS CRATED (IN.) HXWXD 38 x 30.1 x 33 WEIGHT SHIPPING (LBS.) NET (LBS.) 236 208 O Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is bteded inacAHRIcewithdHRIs40. �r WED FOR ® Rated in accordance with AHRI standard 270. I OO Calculated in accordance with Natl. Elec. Codes. Use only HAC circuit bra ifs or uses. ® Standard Air — Dry Coil — Outdoor iPOW ODE CIANCE O This value approximate. For more precise value see unit nameplate..."ivi A . © Max. linear length 60 ft.; Max. lift - Suction 60 ft.; Max lift - Liquid,60 ft. For greater length consult refrigerant piping software Pub. No.32-3312-0' C denotes latest revision). O This value shown for compressor RLA on the unit nameplate and on this specification sheet is used4to compute minimum branch circuit ampacity and max.fuse size.The value showeyfrancliciretselli`I�orl5 current. © No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. A -weighted Sound Power Level [dB(A)] City of Tukwila ra> 111 nl�t!` nlvlcl A FULL MODEL SOUND POWER LEVEL [dB(A)] -WEIGHTED OCTAVE SOUND POWER LEVEL dB - [dB(A)j--Hrgh=Stage---- 63 125 250 500 1000 2000 4000 8000 4TWR5024G 75 50.3 55 58.6 65.3 69.5 64.5 58.6 50.8 Note: Rated in accordance with AHRI Standard 270-2008. © 2011 Trane TRM/E' Trane www.trane.com Mechanical Specification Options General The 4TWR5 is fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, G90 galvanized steel and painted with a weather -resistant powder paint on all louvers, panels, prepaint on all other panels. Corrosion and weather- proof CMBP-G30 DuraTuffTM base. Refrigerant Controls Refrigeration system controls include condenser fan and compressor contac- tor. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The Climatuff® compressor features internal over temperature and pressure protection and total dipped hermetic motor. Other features include: roto lock suction and discharge refrigerant con- nections, centrifugal oil pump and low vibration and noise. ti.eai CERTIFIED., 0 www.ahridirectory.org Unitary Small HP AHRI Standard 210/240 Certification applies only when the complete system Is listed with AHRI. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this unit has a cool- ing capability to 55°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 20° F. Accessories Thermostats — Cooling only and heat/ cooling (manual and automatic change- over). Sub -base to match thermostat and locking thermostat cover. US 10/11 Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. v Submittal AH-1 2 Ton Convertible Air Handler TEM4A0B24S21 SA TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. July 2014 TEM4A0B24-SUB-1A-EN 4_ Ingersoll Rand Outline Drawing A .87 .87- 18.75 D a-d -(7-/ .87 J 1.12 38 6.78 01,70 11P MINIMUM UNIT CLEARANCE TABLE TO SERVICE COMBUSTIBLE CLEARANCE MATERIAL (REQUIRED) (RECOMMENDED) SIDES 0" 2' FRONT 0' 21" BACK 0' 0" INLET DUCT 0' I' OUTLET DUCT I". N/A 1• FOR THE FIRST 3 FT. OF OUTLET DUCT WHEN ELECTRIC HEATERS ARE INSTALLED: 0' AFTER THE FIRST 3 ff. 11.32 rl,75 H 1.331 f 2.15 1.16 2 PLCS PRODUCT DIMENSIONS Air Handler Model A B C D E F H Flow Control Gas Line Braze TEM4A01324S21SA 45.02 18.50 16.50 16.75 4.68 7.33 18.34 TXV 3/4 All dimensions are in inches 2 TEM4A0B24-SUB-1A-EN TR/UYE Product Specifications MODEL TEM4A0B24S21SA RATED VOLTS/PH/HZ 208-230/1/60 RATINGS(a) See O.D. Specifications INDOOR COIL — Type Plate Fin Rows—F.P.I. 3-14 Face Area (sq. ft.) 4.37 Tube Size (in.) 3/8 Refrigerant Control TXV Drain Conn. Size (in.)(b) 3/4 NPT DUCT CONNECTIONS See Outline Drawing INDOOR FAN — Type Centrifugal Diameter -Width (In.) 9 X 7 No. Used 1 Drive - No. Speeds Direct - 3 CFM vs. in. w.g. See Fan Performance Table No. Motors — H.P. 1 - 1/4 Motor Speed R.P.M. 1075 Volts/Ph/Hz 208-230/1/60 F.L. Amps 1.3 FILTER Filter Furnished? (c) No REFRIGERANT R-410A Ref. Line Connections Brazed Coupling or Conn. Size — in. Gas 3/4 Coupling or Conn. Size — in. Liq. 3/8 DIMENSIONS H x W x D Crated (In.) 46 x 21 x 24 Uncrated 45-1/8 x 18-1/2 x 21-1/8 WEIGHT Shipping (Lbs.) / Net (Lbs.) 116/110 (a) These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. (b) 3/4" Male Plastic Pipe (Ref: ASTM 1785-76) to Remote filter required. Minimum Airflow CFM TEM4A0B24S21SA Heater Minimum Heat Speed Tap With Heat Pump Without Heat Pump BAYHTR1504BRK, BAYHTR1504PDC, BAYHTR1504LUG, Low Low 0-BAYHTR1505BRK, BAYHTR1505PDC, BAYHTR1505LUG BAYHTR1508BRK, BAYHTR1508PDC, BAYHTR1508LUG, BAYHTR1510BRK, BAYHTR1510PDC, BAYHTR1510LUG, BAYHTR3510LUG Low Low TE M 4A0B24-SUB-1 A-E N 3 4 TRANE Heater Pressure Drop Table TEM Air Handler Models Airflow CFM Number of Racks Heater Racks 1 2 3 4 Heater Model No. of Racks Air Pressure Drop - Inches W.G. BAYHTR1504 1 1800 0.02 0.04 0.06 0.14 1 > BAYHTR1505 1700 0.02 0.04 0.06 0.14 BAYHTR1508 2 1600 0.02 0.04 0.06 0.13 BAYHTR1510 2 1500 0.02 0.04 0.06 0.12 BAYHTR3510 3 1400 0.02 0.04 0.06 0.12 BAYHTR1515 3 1300 0.02 0.04 0.05 0.11 BAYHTR3515 3 1200 0.01 0.04 0.05 0.10 BAYHTR1519 4 1100 0.01 0.03 0.05 0.09 BAYHTR1520 4 1000 0.01 0.03 0.04 0.09 BAYHTR1521 4 900 0.01 0.03 0.04 0.08 800 0.01 0.03 700 0.01 0.02 600 0.01 0.02 4 TEM4A0B24-SUB-1 A-E N MANE Performance and Electrical Data 1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters. 2. Heater model numbers may have additional suffix digits. Table 1. Air Flow Performance TEM4AOB24S21SA (a) EXTERNAL STATIC (in w.g) AIRFLOW Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS High Med Low t High Med Low t 0.1 984 903 719 946 827 612 0.2 948 868 694 910 796 589 0.3 906 828 665 868 760 567 0.4 858 781 630 820 717 543 0.5 802 726 588 764 666 513 0.6 735 660 537 697 605 0.7 651 581 614 532 1. 2. 3. Values are with wet coil, no filter, and no heaters CFM Correction for dry coil = Add 3% t = Factory setting (0) For TEM4A0B24S21SA, the recommended speed tap is medium at 0.4" external static pressure. Table 2. Electrical Data TEM4AOB24S21SA Heater Model No. No. of Circuits/ Phases 240 Volt 208 Volt Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater 1.3 * 2 15 1.3 * 2 15 BAYHTR1504BRK BAYHTR1504PDC BAYHTR1504LUG 1/1 3.84 13100 16.0 22 25 2.88 9800 13.8 19 20 BAYHTR1505BRK 1/1 4.80 16400 20.0 27 30 3.60 12300 17.3 23 25 BAYHTR1505PDC BAYHTR1505LUG BAYHTR1508BRK BAYHTR1508PDC BAYHTR1508LUG 1/1 7.68 26200 32.0 42 45 5.76 19700 27.7 36 40 BAYHTR1510BRK BAYHTR1510PDC BAYHTR1510LUG 1/1 9.60 32800 40.0 52 60 7.20 24600 34.6 45 45 BAYHTR3510LUG 1/3 9.60 32800 23.1 30 30 7.20 24600 20.0 26 30 * = Motor Amps TE M 4A0B24-SUB-1 A-E N 5 Features and Benefits • Painted metal cabinet with captured foil face insulation • 2% or less air leakage • R-4.2 Insulating Value • Multi -Position UP/Down Flow, Horizontal Left /Right • ALL Aluminum Coil with Enhanced Patented Coil Fin • Electric Heaters with polarized plug connections (sold as accessory) • R-410AThermal Expansion Valve • ECM Motor (3.5— 5 Ton Models ) • Low Voltage Pigtail Connections • Draw Through Design • Horizontal Drain pan • Single Color • Fused 24V Power • 1 year warranty • 10-year warranty registered • Optional extended warranty available Important: Condensate management kit is required for all 5 ton air handler models installed in downflow applications. ui..oai c CERTIFIED,. www.ahrtdirectory.org Unitary Small AC AHRI Standard 210/240 Certification applies only when the complete system is listed with AHRI. r.■:�i CERTIFIED,. 0 www.ahridirectory.org Unitary Small HP AHRI Standard 210/240 Cenihcatton applies only when tic complete system is listed with AHRI. Intertek Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2014 Trane TEM4A0B24-SUB-1A-EN 09 Jul 2014 Supersedes TEM4A0B24-SUB-1-EN (June 2014) 40 Ingersoll Rand amml CERTIFIED® www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 7424783 Date: 9/17/2015 Product: Split System: Heat Pump with Remote Outdoor Unit -Air -Source Outdoor Unit Model Number: 4TWR5024G1 Indoor Unit Model Number: TEM4A0B24S21+TDR Manufacturer: TRANE Trade/Brand name: TRANE Series name: XR15 Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): EER Rating (Cooling): SEER Rating (Cooling): Heating Capacity(Btuh) @ 47 F: Region IV HSPF Rating (Heating): Heating Capacity(Btuh) @ 17 F: 24000 12.00 14.50 22200 8.50 13400 * Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The Information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. Allow ILI AIR-CONDITIONING, HEATING, & REFRIGERATION INSTITUTE we make life better" 130869998081419431 ©2014 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: City of Tukwila Department of Community Development 4/1/2016 MARK SMELTZER 1012 CENTRAL AVE S KENT, WA 98032 RE: Permit No. M15-0151 TUKWILA COMMERCE CENTER 846 INDUSTRY DR Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/16/2016. Based on the above, you are hereby advised to: 1) Ca11 the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/16/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M15-0151 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 rERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0151 DATE: 11/09/15 PROJECT NAME: TUKWILA COMMERCE CENTER SITE ADDRESS: 846 INDUSTRY DR X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: ,9WC kk-t3-ts Building Division ❑ Public Works Fire Prevention Structural El Planning Division Permit Coordinator El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 11/10/15 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Denied (ie: Zoning Issues) (corrections entered in Reviews) Notation: Approved with Conditions DUE DATE: 12/08/15 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 PERFORMANCE HEATING & A/0 INC Page 1 of 2 Home Inicio en Espanol Contact Search L&I A-Z Index Help ely Secure l.kt Safety Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & industries PERFORMANCE HEATING & A/C INC Owner or tradesperson Principals MILLER, DANIEL E, PRESIDENT ERDAHL, DARRIN, VICE PRESIDENT GOWIN, RICHARD L, VICE PRESIDENT (End: 04/26/2011) GOWIN, CONSTANCE F, VICE PRESIDENT (End: 11/15/2007) Doing business as PERFORMANCE HEATING & A/C INC WA UBI No. 600 601 386 1012 Central Ave S KENT, WA 98032 425-251-0356 KING County Business type Corporation Governing persons DANIEL E MILLER DARRIN P ERDAHL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. PERFOHA15ORT Effective — expiration 12/30/1985— 04/30/2017 Bond ........_...... DEVELOPERS SURETY & INDEM CO Bond account no. 748802C Active. Meets current requirements. $12,000.00 Received by L&I Effective date 11/27/2007 10/01/2007 Expiration date Until Canceled Insurance .............................. American Fire & Casualty Co $1,000,000.00 Policy no. BKA56064545 Received by L&I Effective date 04/06/2015 04/28/2014 Expiration date 04/28/2016 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600601386&LIC=PERFOHA15ORT&SAW= 11/18/2015 DO'S77NG SUPPLY PLENUM 2x4 Cal 2'OC CONNECT NEW 8 "o OA DUCT TO EXJSTING 120IUCT N HVAC SYSTEM PARTIAL PLAN (AH-1) SCALE 1/8" =1=0" 3 1/2 x 13 @ 8'O.0 SEE ENLARGED 'B" HP- PLAN, •�ar� 31/2x13@8'O.0 L1_ EXISI7NGROOF PORTAL FOR REFRIGERANT PIPING u EXIST7NGFRESH AIR INTAKE HOOD. CONNECT EXIST7NG12" 0 DUCT TO NEWB'DUCT. 1_, I I:1 O IN N EQUIPMENT ROOF PARTIAL PLAN SCALE: 1/8" =1=0" H-1 RO.C. 31/2x13'8'O,C, 31/2x138'O.C, EXIS77NGSUPPLY PLENUM NOTE' MODIFY EXISTING EQUIPMENT SUPPORT TO SUIT NEW UNIT& PROVIDE SEISMIC BR4CE ENLARGED PLAN "A" AH-1 SCALE 1/4" =1=0" HP-1 NEW 5/16"x1 "LAG SCREW, TYR OF(4) NEW4x4 WOOD SLEEPERS W/C4P 1/ANGER BOLT (4) TO ATTACH TO SLEEPERS TO PURLIN & UNISTRUT(P1000) TO SLEEPERS ROOFING MATERIAL UNDER SLEEPER CHEMCURBSYSTEM PENETR4TI0N SEALS, TYP OF(4) EXISTING3x13 @8' - E17S77NG2142'O.0 ft1 SECTION VIEW (A -A 9 END VIEW (B-B9 HP -I NEW 5/16"x13- "LAG 0 NEW4x4x4'L WOODSLEEPERSW/ C4P, TYP. OF(2) i'X10"HANGER BOLT (4) TOATTACH 31/2x138'0,C SCREW,, TYP. OF(4) TO SLEEPERS TO PURLIN& UNISTRUT (P1000) TO SLEEPERS. CHEMCURBSYSTEM PENETR4T70N SEALS, TYP OF(4) 31/2x13@8'O.C. c) WRING FRESH AIR INTAKEHOOD. CONNECTEXISTING 12"0DUCT TO NEW8"DUCT. ENLARGED PLAN "B" HP-1 SCALE 1/4" =11-0" SPLIT SYSTEM SCHEDULE HEAT PUMP TAG MfCR. DESLTUP170N MODEL NOMINAL INDOOR FAN COOLING DATA HE477NGDATA REFRIG. PIPE ELEC/RI04L DATA MIN SOUND WEIGHT TONS CFM ESP HP B7UH SEER EER B7UH LIQUID GAS HTR VOLTS PH. MCA MOCP OSA d84 LBS AH-1 TR4NE AIR HANDLER 7EM4A0B24 SEEHPI 800 0.4 1/4 SEEHPI SEEHP-1 SEEHP-1 NA 3/8" 5/8" 5KW 208 10 27 30 NA 110 HP-1 TR4NE HEAT PUMP CONDENSING UNIT 47WR5024G 1 800 - NA *24,000 *14,50 *1200 *22,200 3/8" 5/8" 208 10 11 15 NA 75 208 EXIS77NGCONDENSING UNIT TO BE REPLACED SEISMIC ATTACHMENT DET NOT TO SCALE 9 VIP--1 LIMIT OFWORK J ROOF KEY PLAN N { OA INTA HOOD PARCEL NOS.: 2523049015 LEGAL DESCRIPTION.• BEG ATE1/4 COR OFSEC 26-23-04 THN88-06-42 W105.84fT THS01-47-28 W 90.66FT THS88-1232E233fT TO TPOB THFR TPOBS88-1232E291,50fT TAP ONSWLYMGNOFJAMESCYRISTENSENRDNO 1479 77/ ALG SD SWLY MGN S 3239-25W96,43fT THS20-1625W 114.09FT THS03-06-25W 122.73PT THS 02-4135E.98.54FT THS19-53-35E16886fT THS313835E158.24FT THS 44-38-35E25.37fT THLEAVING SWLYMGNS01-47-28 W 461.42FT THN88-1232 W254FT TH N 01-47-28 E 18 fT TAP OF NLY MGN OF MINKLER BLVD THALGSD MGNN88-1232 W103FT TAPONC,/L OFPRIVATEDRIVE THALGSD C/L N01-47-28 E430FT TAP OFCURVE 77/ TANGENT TO PRECEDING WORSE ALGARC OFCURVETO LFT77.78FTR 0250fT&C,/A17-49-33TAP OFREV CURVE THFRATANGENTWH BEARSN16-02-05WALGARC OFCURVE TORGT77.78fTR4D250PT& C,/A 17-49-33 TAP OF TANGENCYT7f TANGENT TO PRECEDING CURV E N 01-47-28 E 577.17 FT TO TPOBSUBJ TO UPR4 OPER ESMTS 5coPEOf11/13e( REPLACE FAILINGEXISTING2 TON SPLIT SYSTEM HE4TPUMP WITH LIKE -FOR -LIKE UNIT IN THESAME LCC4TI0N, AS SHOWN IN DRAWING. INSTALL NEW OUTDOOR UNIT ON NEW SLEEPERS FASTEN TO ROOF STRUCTURE PROVIDE SEISMIC FASTENINGPER ATTACHEDEQUIPMENT DETAILS. RECONNECT THE NEW NEW UNIT TO EXISTINGAIR SUPPLY& RETURN DUCTS, LINE VOLTAGE, LOW VOLTAGE POWER SUPPLY AND OTHER U77L177ES, CrODENOTES; 1) SEAL DUCTSPER W.S,EC SEC770NC403.27 2) INSULATEDUC7WORKPER W.5EC SECTIONC403.27 3) SYSTEMHP-1/AH-1 TOBEEXEMPTFROM ECONOMIZER REQUIREMENTSPER W.S.E.0 TABLE C1014,3.1(ECONOMIZER COMPLIANCE OP77ONS FOR MECf14NICAL ALTER4770NS)NOTE 5b. 4) A 110V CONVENIENCE OUTLE T SHALL BEWITHIN25'-0"OFOUTDOOR EQUIPMENT PER I.M.C. SECTION306. 5) ROOFACCESS TO EQUIPMENT TO COMPLY WIIHI.M.C. SEC770N306. 6) THERMOSTAT TOCOMPLY W/SECTION C403.24OFWSEC 846Industry Dr, Tukwila, WA 98038 iukrlifp Fires? ¢ ft N VICINITY MAP NTS R No changes shall bo made to the scope of wilnk without prior approval of /Tukwila Building Division, NOTE: Revisions will require a new plan submittal an may include additional plan review fens. 846 tndu 1 Plan review approval is subject to errors and omissions. pproval of construction documents does not auth rize the violation of any adopted code or ordinance. Re ipt of\approved Field Copy and conditions is acknowle god: Properly Line, Typ. FILE COPY Permit No. By: Date: 11 /1 City of Tukwila BUILDING DIVtiJ9Ni;1Ep �;¢•, ;' ,-,,: TUKWIL RLVIEINED FO COD `.OMPLIANCE APE ROVED NOV 16 ; r• SITE PLAN N NOV 0 5 2015 SI �r_tMIT CENTER A Dynamic Solutions for the Built Enviroment (425)251-0356 OR (800)696-4149 FAX: (253)667-5775 • SEP/ FATE PERMVMIT KEQUIRED FOR: 0 Mechanical Ntectrical Eiliumbing as Piping City of Tukwila y1LOING DIVISION_. REVISIONS LL 0 0 J a. Z 2 n. CY LU 0 a. co J a. MAP & EQPMNT SCHED DATE: 11/03/2015 DRAWN: GR ENGR: GR APPVD: MS JOB NUMBER: 104414 NOTES:1. SYS7EMHP-r/AH-1 TOBEEXEMPTFROM ECONOMIZER REQUIREMENTS PER W,S.EC TABLE C101.4.3.1(ECONOMIZER COMPLIANCE OP77ONS FOR MECHANIC4L ALTERATIONS) NOTE 5b. 2 *PERAHRI CERTIFIED REFERENCENO.:7424783 SCALE: 1" =30' NOT TO SCALE • M1 ET 1 OF 1