Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M15-0155 - BOEING #9-120 - STRAIN GAUGE
BOEING #9-120 STRAIN GAUGE 9725 E MARGINAL WAY S M15-0155 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0003400018 Permit Number: M15-0155 9725 E MARGINAL WAY S BLDG 9-120 Issue Date: 12/4/2015 Permit Expires On: 6/1/2016 Project Name: BOEING #9-120 - STRAIN GAUGE Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 CONNIE HARDIN 4600 S 134 PL , SEATTLE, WA, 98168 HOLADAY PARKS INC 4600 S 134 PL, SEATTLE, WA, 98168 HOLADP1379NO Phone: (206) 250-4530 Phone: (206) 248-9700 Expiration Date: 9/3/2017 DESCRIPTION OF WORK: INSTALLING INTAKE & EXHAUST DUCTING FOR BOEING TEST OVEN. OVEN TO BE INSTALLED AND PERMITTED BY OTHERS. Valuation of Work: $55,000.00 Type of Work: NEW Fuel type: Fees Collected: $927.82 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2014 2014 2014 2012 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this developmd agre to the conditions attached to this permit. Signature: Print Name: 711,4r`e���t� Date: I - ( 7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Mechanical Permit No. Nit t LV ` 0 (Es - Project No. Date Application Accepted: 11 Date Application Expires: For ()lice use onl MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address / 2, Tenant Name: PROPERTY OWNER Name: Q • Address: CityS P.Ak Statp:-"L Zilvo CONTACT PERSON — person receiving all project communication Name• A n ot. 4.4GtTL�l_ /� Address: J / 00 S v3t-{�I(i� (�� ", 1t City: State '� Zipt te Phoneit• 62-V1 O F UU�2.4 g 76 6 Email1D11hlalt 0 GL G.u► %. WW1 King Co Assessor's Tax No.: b3 LOW / b Suite Number: New Tenant: Floor: ❑ Yes Imo.. No MECHANICAL CONTRACTOR INFORMATION Company Name: / .a ,, . 2, P Address:I/ _ QO c (s Citeee&Ltkt Stag _ ^�GZip4 �, (61 AC LZ_ Phono b & zoci ✓3d Fax:Lzoo i_ts ewe Contr Reg Npt:, w�1 0xp Date�d_?-ell Tukwila Business License No.: Valuation of project (contractor's bid prce): $ Describe the scope of work in detail: • Use: Residential: New ❑ Replacement Commercial: New ❑ Replacement ❑ 6YCr� (bye".-e (kaAdt avach '1-0 Fuel Type: Electric ❑ Gas ❑ Other: H:\Applications\Fors-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > 100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN U HORIZ GENT: Signature: Date: --I4- � - f1/� Print Name: ;t, � e Day Telephone: //V6.2 ST .0 0 City Mailing Address:LI (OO S 1 J H:\Applications'Forms-Applications On Line12011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Lk.. C(1(10 State Zip Page 2 of 2 DESCRIPTIONS I ACCOUNT PermitTRAK QUANTITY I PAID $927.82 M15-0155 Address: 9725 E MARGINAL WAY S BLDG 9-120 Apn: 0003400018 $927.82 MECHANICAL $892.13 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $681.20 PLAN CHECK FEE R000.322.102.00.00 0.00 $178.43 TECHNOLOGY FEE $35.69 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6692 R000.322.900.04.00 0.00 $35.69 $927.82 Date Paid: Thursday, November 19, 2015 Paid By: CONNIE HARDIN Pay Method: CREDIT CARD 04484G Printed: Thursday, November 19, 2015 3:48 PM 1 of 1 n L! LJ LISYSTEMS Ice INSPECTION RECORD Retain a copy with permit I i' iN NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr ect: ( ti T7 � f i Zi° Type of lnsp ction: r ./14 j / A dress: ,. Pad Wait Date Called: .fr f Special Instructions: Date Wanted: 3 -(6 - / a.m. p.m. Requester: Phone No: QApproved per applicable codes. Corrections required prior to approval. OMMENTS: b� fa Fah, Inspector: Date:3 _ I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Ai Retain a copy with permit "(% WO. " PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr ject: r Poe( 114- f � Type of Inspection: rC Agr7z=3-77es, ,A ` ( tuk VDateCalled: Special Instructions:/` / Date Wi to : a.m. P.m. Requester: Phone No: nApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date:.. REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Protect: c 0e_(� q 1 `/ 2® Type�of`Inspection: /ti C. r(,) dress: •1 Pate Called: Special Instructions:e kI Wanted: z-74 a.m. P.m. —_,6 Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: e tvirl A-#41 Inspector: Date Z^ / REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Retain a copy with permit INSN NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECORD /V115""0(y75- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: ,. 00��' ¥( .q _/ z-o Type of Inspection: c �-, %r Address: c Date Called: Special Instructions: (( per ry� Date Wanted:j9(/ Z l (✓(j a.m. p.m. Requester: Phone No: LiApproved per applicable codes. Corrections required prior to approval. COMMENTS: frt-Sk h e Pro Lij de 6 ti Ps- C cmv ,& d &q 1oriC r fr\svk (c('tc a r C t OL<e_R ,/" ((&% fp e �f i,,J �' j. pCeft S QIC(Y`qr IxtVii-- e_. Inspector: Dater tq l i REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, INSPECTION RECORD5-6 Retain a copy with permit /10 TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Prpigct: qq t�0t NJ`�ol�� _ ( Type of In??fi�ction: / A G' 4 Address: _ _ ate Call d: S%ual Instructions: �f 4eWanted: 7 a r • • Requester: Phone No: 11 Approved per applicable codes. Corrections required prior to approval. COMMENTS: L A ek Inspector: Date: % 2Wit"/ ((I`'''/' f L� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. re Y INSPECTION RECORD ���� �� 1i Retain a copy with permit 1 CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prof t: f i/ O l /V d - Type of lns ction: I kcsq f / v1/ C/L. dress:5 /� �A %�A �L D,aSte Called: //7/ q-ye Special Instructions: j //t c Date Wanted: eLL.,,� / ,7m- Requester: Phone No: riApproved per applicable codes. I Corrections required prior to approval. COMMENTS: Verr Inspector: raT7-7-1,6 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ru SMART Mechanical Solution? WA: 4600 S 134th PI, Seattle, WA 98168 1206.248.9700 ( fax 206.248.8700 AK: 1820 Marika, Fairbanks, AK 99709 J 907.452.7151 I fax 907.452.3800 wtnv.HOLADAYPARKS.tom Vt30t3S March 14, 2016 Subject: Boeing 9-120 Strain gauge oven project, double wall vent pipe integrity To Whom It May Concern: This letter is to confirm that I have reviewed the reported dents, blemishes, and scuff marks on the double wall vent pipe installed at the Boeing 9-120 project. The photos of these items are attached this letter for reference. After reviewing the attached photos and discussing the installed conditions with the project manager, I have observed that these dents, blemishes, and scuff marks only impact the appearance of the surface of the exterior wall of the double wall vent pipe. Further, the dents, blemishes, and scuff marks shown in the photos will not have any impact on the performance or integrity of the installed double wall bent pipe. I have also noted that the manufacturer of the double wall vent pipe has reviewed the same photos and has provided a similar response to the product representative, Jeff Burpee, in regards to this same issue. If you any questions, please feel free to contact me at 206-988-4451. Michael Cook, P.E., Engineering Manager Design Build Division HOLADAY-PARKS, INC. 206.248.9700 main 206.988.4451 direct 206.248.8701 fax m ichaelc(a�hoiadavparks.com HOLADAYPARKS.COM CITY OF TREUKWILA MAR 16 2016 PERMIT CENTER ass February 23`d, 2016 Jeff Burpee CHC Columbia Hydronics Sales Engineer Subject: Boeing 9-120 strain gauge oven project Jeff; This is to confirm that I have reviewed the pictures of the CIX chimney you sent via Email and the damage shown is only cosmetic and will not in any way affect the integrity of the inner sealed venting. Sincerely Eric Dufour, Eng. Engineering Director SecuiTtk Chimneys RECEIVED CITY OF TUKWILA MAR 16 2016 PERMIT CENTER r RECEIVED CITY OF TUKWILA MAR 18 2016 PERMIT CENTER PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0155 DATE: 11/19/15 PROJECT NAME: BOEING #9-120 SITE ADDRESS: 9725 E MARGINAL WAY S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: q14 Building Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 11/24/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections enteredin Reviews) 111116 Notation: Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 12/22/15 n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 HOLADAY PARKS INC Page 1 of 3 Horne I.rucio en 1'spa.nol Contact. Search L&I A-Z .Index Help My Secure L&:I Safety Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries HOLADAY PARKS INC Owner or tradesperson BECK, DAVID CARL Principals BECK, DAVID CARL, PRESIDENT CONNELL, DANIEL A, PRESIDENT GIRI, BIJIT, PRESIDENT PIZZEY, GRACE K, VICE PRESIDENT FREEL, JERRY LEE, VICE PRESIDENT PARKS, GERALD T JR, PRESIDENT (End: 08/12/2015) NAILON, JUNE ANNETTE, VICE PRESIDENT (End: 08/12/2015) O'CONNOR, BONNY K, SECRETARY (End: 08/12/2015) BECK, DAVID CLARENCE, TREASURER (End: 08/12/2015) VAN DER VEEN, ERIC M, VICE PRESIDENT (End: 08/14/2013) PIZZEY, GRACE KATHERINE, VICE PRESIDENT (End: 08/14/2013) VAN DER VEEN, JULIE ELIZABETH, MEMBER (End: 08/14/2013) CONNELL, DANIEL AARON, MEMBER (End: 08/14/2013) GIRI, BUIT, MEMBER (End: 08/14/2013) KIEL, RINALD HOWARD, MEMBER (End: 08/14/2013) WHITMYRE, CHRISTIAN, MEMBER (End: 08/14/2013) NELSON, MICHAEL, SECRETARY (End: 11/04/2010) PARKS, DAVID L, TREASURER (End: 11/04/2010) TALBOT, PAUL, TREASURER (End: 11/04/2010) WA UBI No. 578 004 089 4600 S 134TH PL SEATTLE, WA98168 206-248-9700 KING County Business type Corporation License https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 12/03/2015 vc \TY V A D 0 99 0 99 EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE—TACOMA AIRPORT PROJECT SITE FROM DOWNTOWN SEATTLE y�c 599 TUKWILA 900 EXIT 157 rn m EXIT 158 Q FROM KENT & AUBURN EXIT 157 900 # 26 v CI\ TV VA D 3UILDI\G A»HSS: 9725 EAST vAGI\AL WAY SOUTH TU<WILA, WASHI\GTO\ PROJECT SITE 9-078 9-35 9-52 0 MFC D ROJ CTS V VAHV DESCRIPTION OF WORK: CONTRACTOR: OWNER: 9-120 STRAIN GAUGE OVEN ADDRESS AND TELEPHONE NUMBER (WHEN KNOWN) BOEING DEVELOPMENTAL CENTER OE/NG ® 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 PROJECT MANAGER : GARY FULLMER TEL. 206-294-1430 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. crr.ti,F?A,T E PEF,MIT F _EQJI ED FOR: ❑ Mechanical I±!ectricai C jambing as Piping City of Tukwila `-`ING DIVISION E\YUD FOR E.COMPLIANCE .,� APP OVED DEC 0 2 2015 Ci of Tukwila WILDING DIVISION \DFX OF DRAW \GS INCLUDED IN SET SHEET NO. DRAWING TITLE REV DATE • DRAWING NO. ACHITECTUAL • 9-120—GO GO COVER SHEET — 06.30.15 • 9-120-1A11R 1A11R FLOOR PLAN —REMOVAL B 06.30.15 • 9-120-1A11 1A11 FLOOR PLAN K 06.30.15 STCTUAL • 9-120—S518 S518 MISC. SECTIONS AND DETAILS A 07.08.15 VEC-A\ICAL • 9-120—M2C M2C LEGEND AND ABBREVIATIONS — 04.07.15 • 9-120—M1C M1C LEGEND AND ABBREVIATIONS — 04.07.15 • 9-120—M2D M2D MECHANICAL GENERAL NOTES — 04.07.15 • 9-120-1M11 1M11 HVAC FIRST FLOOR L 04.07.15 • 9-120-1M111 1M111 FIRST FLOOR PLUMBING PLAN V 07.08.15 • 9-120-1M261 1M261 FIRE PROTECTION PLAN VIEW J 07.08.15 • 9-120-1M361 1M361 INDUSTRIAL VENTILATION FIRST FLOOR PLAN G 07.08.15 • 9-120—M456 M456 ENLARGED PLAN A 07.08.15 • 9-120—M537 M537 DETAILS B 07.08.15 • 9-120—M542 M542 SECTION A 07.08.15 ELECTRICAL 0 9-120-1E111R 1E111R PARTIAL 1ST FLOOR 480Y/277V POWER PLAN Q 07.08.15 • 9-120—E4S11R E4S11R ONE LINE DIAGRAM SUBSTATION 11 C 07.08.15 • 9-120-1E11 1E11 PARTIAL 1ST FLOOR LIGHTING PLAN G 07.08.15 • 9-120-1E61 1E61 PARTIAL 1ST FLOOR 208Y/120V POWER PLAN F 07.08.15 • 9-120-1E111 1E111 PARTIAL 1ST FLOOR 480Y/277V POWER PLAN Q 07.08.15 • 9-120-1E361 1E361 PARTIAL 1ST FLOOR COMMUNICATIONS PLAN B 07.08.15 • 9-120—E4S11 E4S11 ONE LINE DIAGRAM SUBSTATION 11 C 07.08.15 FILE COPY Permit Pa®. M ( ' 0 [SS — Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fiol = anitions is acwiedged: By: Date: City of Tukwila BUILDING DIVISION ISSUED FOR CONSTRUCTION JULY 8, 2015 RECEIVED CITY OF TUKWILA NOV 19 2015 PERMIT CENTER S (7-.E cot, Wood Harbinger 3oog with Ave NE, Suite ioo Bellevue WA 98004 4 5.628.6000 woodharbinger.com REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 9-120 STRAIN GAUGE OVEN 26032-01 WH MBL 07.08.15 Q� OE/N C'- ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN C. PECK DATE SUBTITLE 03.13.15 CHECKED S. GRAYSON 03.13.15 COVER SHEET CURRENT REVISION SYMBOL 26032-01 DATE 07.08.15 ENCINEER M. LEHNER 03.13.15 CHECKED S. GRAYSON 03.13.15 APPROVED APPROVED TITLE CENFRAI 9-120 STRAIN GAUGE OVEN BUILDING 09-120 SHEET GO JOB NO. 21067 COMP NO. DWG NO. DFV. CFNTFR. WA 09-170—Go vFc A\ CAS VAC LI-G1-\D LEGE\D GENERAL SYMBOL DESCRIPTION RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN k 24x12 k 24x12 24x12--N, DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST �� ROUND DUCT, NUMBER INDICATES DIAMETER 240 / 240 OVAL DUCT, FIRST NUMBER INDICATES MAJOR DIAMETER, SECOND NUMBER INDICATES MINOR DIAMETER Q 24x120 4 24x120 ? AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING TOWARDS XSUPPLY N./ SUPPLY AIR SQUARE RECTANGULAR ELBOW FACING AWAY EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING TOWARDS -� T/% EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING AWAY AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW FACING TOWARDS /EXHAUST EXHAUST AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW FACING AWAY 1 TRANSITION RECTANGULAR TO RECTANGULAR HEEL TAP OR LOW LOSS TRANSITION AT TAKE OFF FROM OVAL TO ROUND OR ROUND TO ROUND =� ,y" (E-J<F1. TRANSITION SQUARE OR RECTANGULAR TO ROUND OR OVAL CONICAL SPIN -IN W/ VOLUME DAMPER (NOT SHOWN) V UP DUCT OFFSET UP OR DOWN -4'1-- 1 DN BLADE DAMPER rillOPPOSED PARALLEL BLADE DAMPER VOLUME DAMPER DUCT DAMPER, MOTOR OPERATED (ELECTRIC) +----t BACK DRAFT DAMPER (ALLOWS FLOW IN DIRECTION OF ARROW) juit_n_ BDD AD OR AP ACCESS DOOR (AD) OR ACCESS PANEL (AP) M. FD FIRE DAMPER TFD SFD SMOKE FIRE DAMPER, PROVIDE ACTUATOR ON SIDE INDICATED WITH DIAMOND ?SFD GENERAL SYMBOL DESCRIPTION RECTANGULAR TURNING VANEDUCTS SQUARE ELBOW WITH -.21:-)) RECTANGULAR DUCT, LONG RADIUS ELBOW SCOOP OpEXTRACTION 'W-I FLEXIBLE DUCT DUCT CONNECTION rirFLEXIBLE SIDEWALL SUPPLY AIR DIFFUSER, GRILLE OR REGISTER __ SIDEWALL RETURN/EXHAUST AIR GRILLE OR REGISTER ...-Ar_ SCREENED OPENING illa It-lI ice- (SO) M500 CEILING DIFFUSER, DIRECTION Alk OF FLOW SHOWN M500 —® iiiilk / f L. RETURN GRILLE M500 AND GRILLE illa LINEAR DIFFUSER M501 RETURN/EXHAUST REGISTER OR GRILLE HARD DUCT CONNECTION -f • (-41 WALL TRANSFER BOOT,(TB1) M500 UNIT HEATER 0 SOUND ATTENUATOR INLINE EXHAUST FAN + i 4 —® SUPPLY AIR FLOW DIRECTION, POSITIVE PRESSURE --iv--1.RETURN, OUTSIDE OR EXHAUST AIR FLOW DIRECTION, NEGATIVE PRESSURE GENERAL SYMBOL DESCRIPTION 0 TEMPERATURE SENSOR THERMOSTAT T O HUMIDITY SENSOR © CARBON DIOXIDE SENSOR 0 OCCUPANCY SENSOR, CEILING DUCT TYPE SMOKE DETECTOR o © PRESSURE SENSOR Om. PRESSURE SENSOR HIGH/LOW LIMIT DIFFUSER AND GRILLE CALLOUTS CEILING DIFFUSER, MARK CD, SEE SEE SCHEDULE FOR TYPE M500 CDX-200 DESIGN CFM, SEE SCHEDULE FOR DIFFUSER AND GRILLE NECK SIZE, TYPICAL EGX-CFM = EXHAUST GRILLE RGX-CFM = RETURN GRILLE SGX-CFM = SUPPLY GRILLE VAV TERMINAL LEGEND TERMINAL BOX IDENTIFIER: 1ST CHARACTER: V = VARIABLE AIR VOLUME TERMINAL UNIT 2ND CHARACTER: C = SINGLE DUCT F = SERIES FAN POWERED 3RD CHARACTER: C = COOLING ONLY W = HOT WATER COIL �CX; MARK NUMBER 3RD CHARACTER: # = QTY GREATER THAN ONE 2ND CHARACTER: X# = GRIDLINE 1ST CHARACTER: # = FLOOR PM = PENTHOUSE I SINGLE DUCT TERMINAL UNIT illik WITH HEATING COIL M500 q ii 1 SINGLE DUCT TERMINAL UNIT aillk WITHOUT HEATING COIL M500 I I SERIES FAN POWERED TERMINAL UNIT WITH HEATING COIL M500 ABBREVIATIONS ABBREVIATION DESCRIPTION A AAV AD ADD AF AFF AMS AP APPROX ARCH AUD AVG BI BDD BFP BHD BHP BLDG BOD BOP BOS BTU BTU H BW C Cv °C CAP CC CCW CFM CI COMB CONN CONT COTG CPLG CW DA DB DBD DI DIA 0 DIM DL DN DS DWG dB DP EA EAT EFF ELL ELEC ELEV, EL ESP ETP EVAP EWT EXH EXIST EXT °F F FC FD FLR FCO FOB FOF FOIC FOT FPM FS FT FV FIN GAL GPM GALV GA GCO HC HD HORIZ HP HPC HR HVAC HPU HTG ID IE ANCHOR AUTOMATIC AIR VENT ACCESS DOOR ANGULAR DOWN DISCHARGE AIR FOIL WHEEL ABOVE FINISHED FLOOR AIR MEASURING STATION ACCESS PANEL APPROXIMATELY ARCHITECTURAL ANGULAR UP DISCHARGE AVERAGE BACKWARD INCLINED WHEEL BACK DRAFT DAMPER BACKFLOW PREVENTER BOTTOM HORIZONTAL DISCHARGE BRAKE HORSE POWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR BUTTWELD COMMON FLOW COEFFICIENT TEMPERATURE - DEGREES CELSIUS CAPACITY COOLING COIL COUNTER CLOCKWISE ROTATION CUBIC FEET PER MINUTE CAST IRON CENTER LINE COMBUSTION CONNECTION CONTINUED/CONTINUATION CLEAN OUT TO GRADE COUPLING CLOCKWISE ROTATION DIRECT ACTING DRY BULB TEMPERATURE DOWN BLAST DISCHARGE DUCTILE IRON DIAMETER DIMENSION DELUGE DOWN DOWNSPOUT DRAWING DECIBELS DRY PIPE EXHAUST AIR / EACH ENTER AIR TEMPERATURE (°F) EFFICIENCY ELBOW ELECTRICAL ELEVATION EXTERNAL STATIC PRESSURE ELECTRONIC TRAP PRIMER EVAPORATOR ENTERING WATER TEMPERATURE EXHAUST EXISTING EXTERIOR / EXTERNAL TEMPERATURE - DEGREES FAHRENHEIT FREEZE STAT FORWARD CURVE WHEEL FIRE DAMPER FLOOR FLOOR CLEAN OUT FLAT ON BOTTOM FACE OF FLANGE FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FLAT ON TOP FEET PER MINUTE FLOW SWITCH, FIRE SPRINKLER (WET PIPE) FEET FACE VELOCITY FPM FIRE WATER GALLONS GALLONS PER MINUTE GALVANIZED GAGE, GAUGE GRADE CLEANOUT HEATING COIL. HEAD - FEET OF WATER HORIZONTAL HORSEPOWER HIGH PRESSURE CONDENSATE HOUR HEATING, VENTILATING AND AIR CONDITIONING HEAT PUMP UNIT HEATING INSIDE DIAMETER INVERT ELEVATION ABBREVIATIONS ABBREVIATION DESCRIPTION IGV INSUL IN INT KW KVA LAT LBS, # LWT MA MAX MBH MCC MECH MIN MOV MTD, MTG NC NIC NO NTS NPSH OA OBD OCC OF OS&Y OD OVHD PBD PD/o P PDI PIV PLS POC POS PRESS PRV PS PSIG PSV RA RECT REF REV RH RM ROT RPM RQD RTN SA SCFM SHC SHF SHT SO SOV SP SQ SS STL STRUC SW SUCT TDH TEMP TH THC THD THRD TOD TOS TO P TP TS TS P TV TYP UBD VAV VD VP VERT VTA VTR WB WG WCO WS WSEC WHA INLET GUIDE VANE INSULATION INCHES INTERMEDIATE KILOWATT KILOVOLT -AMPERE LEAVING AIR TEMPERATURE (°F) POUNDS LEAVING WATER TEMPERATURE (°F) MIXED AIR MAXIMUM HEAT CAPACITY BTU PER HOUR X 1000 MOTOR CONTROL CENTER MECHANICAL MINIMUM MOTOR OPERATED VALVE MOUNTED, MOUNTING NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN / NUMBER NOT TO SCALE NET POSITIVE SUCTION HEAD OUTSIDE AIR OPPOSED BLADE DAMPER OCCUPANCY SENSOR OVERFLOW OUTSIDE SCREW AND YOKE OUTSIDE DIAMETER OVERHEAD PARALLEL BLADE DAMPER PRESSURE DROP OR DIFFERENTIAL PRESSURE PLBG. & DRAINAGE INSTITUTE POST INDICATOR VALVE DUCT PRESSURE LIMIT SWITCH POINT OF CONNECTION POSITION PRESSURE PRSSURE REGULATING VALVE PRESSURE SWITCH PRESSURE - POUNDS PER SQUARE INCH, GAUGE PRESSURE RELIEF (SAFETY) VALVE REVERSE ACTING (CONTROLLER) / RETURN AIR RECTANGULAR REFERENCE REVISED RELATIVE HUMIDITY ROOM ROTATION REVOLUTIONS PER MINUTE REQUIRED RETURN SUPPLY AIR CUBIC FEET OF AIR, AT STANDARD CONDITIONS SENSIBLE HEAT CAPACITY SENSIBLE HEAT FACTOR SHEET SCREENED OPENING SOLENOID OPERATED VALVE STATIC PRESSURE SQUARE STAINLESS STEEL STEEL STRUCTURAL SOCKET WELD SUCTION TOTAL DYNAMIC HEAD (FEET OF WATER) TEMPERATURE TOTAL HEAD (FEET OF WATER) TOTAL HEAT CAPICITY TOP HORIZONTAL DISCHARGE THREADED TOP OF DUCT TOP OF STEEL TOP OF PIPE TOTAL PRESSURE TEMPERATURE SWITCH TOTAL STATIC PRESSURE TURNING VANE TYPICAL UP BLAST DISCHARGE VARIABLE AIR VOLUME VOLUME DAMPER VELOCITY PRESSURE VERTICAL VENT TO ATMOSPHERE VENT THROUGH ROOF WET BULB TEMPERATURE WATER GAUGE (INCHES OF WATER) WALL CLEAN OUT WET STAND PIPE WASHINGTON STATE ENERGY CODE 2009 WATER HAMMER ARRESTOR 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M2C, M 1 C, AND M 1 E. 2 DESIGNATES EQUIPMENT APPEARING ON MECHANICAL EQUIPMENT SCHEDULES. GE\EAL \OTES 1. GENERAL NOTES ON SHEET M2D SHALL APPLY. 2. SOME ABBREVIATIONS AND SYMBOLS INCLUDED IN THE LEGENDS MAY NOT BE FOUND ON ANY DRAWINGS. -FETE\CE DAWI\GS CO\STUCTIO\ \OTES REVEWED FOR ODE COMPLIANCE APPROVED DEC 0 2 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 19, 2015 PERMIT CENTER OH PPPFR FACILITY DESIGN BY WH \C O\LY DATE 07.08.15 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 9-120 STATION 5 AHU REPLACEMENTS 21067 WH MBL 04.07.15 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE LEGEND AND ABBREVIATIONS CURRENT REVISION 21067 SYMBOL DATE 04.07.15 APPROVED BY DEPT. DATE ENGINEER CHECKED TITLE 9-120 STATION 5 AHU REPLACEMENTS SHEET M2C 12/2/2014 8:48:34 AM APPROVED APPROVED ►Jr/NI IAAIInAI l lAr'`Trn BUILDING 9-120 JOB NO. 21067 COMP NO. nm, nrnITrn tASA DWG NO. n 1 nn ►lnn W CL V I-C A\CAL PI ID I\G LHCH\D GENERAL SYMBOL DESCRIPTION BREAK IN PIPE —1 t— CROSSING LINES, NO CONNECTION 1 DIRECTION OF FLOW SLOPE DIRECTION OF SLOPE, DOWN c© EQUIPMENT MARK NUMBER EXIST EXISTING WORK EXISTING TO BE REMOVED /////// HIDDEN OR BELOW GRADE IN -LINE RECIRCULATING PUMP --o0— INSULATED PIPE 4) G= INSULATED PIPE WITH ELECTRIC HEAT TRACING i____$' NEW WORK POINT OF CONNECTIONPOC PUMP --o FIXTURES SYMBOL DESCRIPTION 0 CIRCULAR WASHFOUNTAIN DRINKING FOUNTAIN DF 10 Ewc ELECTRIC WATER COOLER ELECTRIC WATER COOLER FOR HANDICAPPED rEd EWCH FLOOR DRAIN O FD FLOOR SINK O FS Q LAv LAVATORY, ROUND COUNTER MOUNT ® LAV LAVATORY, RECTANGULAR COUNTER OR WALL MOUNT ©RD (OFD) ROOF DRAIN (OVERFLOW DRAIN - ROOF) IEI EWF SAFETY EYE WASH FOUNTAIN ED SSEW SAFETY SHOWER AND EYE WASH SEMI -CIRCULAR WASHFOUNTAIN SERVICE SINK, FLOOR MOUNT D ss ss SERVICE SINK, WALL HUNG SHOWER STALL AND FIXTURE ____ EI UR URINAL, WALL HUNG E:::)wc WATER CLOSET, FLUSH VALVE, WALL HUNG 0 we WATER CLOSET, FLUSH VALVE, FLOOR MOUNT WASTE FITTINGS SYMBOL DESCRIPTION 1/4 BEND --+)- co CLEAN OUT, EXPOSED FCO CLEAN OUT, FLOOR _O wco CLEAN OUT, WALL --� FFD FUNNEL FLOOR DRAIN O FUD FUNNEL DRAIN O LATERAL <I TRENCH DRAIN III[�]ilI O wR WASTE RECEPTOR, ROOF WYE AND 1/8 BEND, SHOWN WITH CLEAN OUT 11I Co PIPE IDENTIFICATION SYMBOL DESCRIPTION COMPRESSED AIR, PLANT A ARGON GAS AR ACID WASTE AW CONDENSATE RETURN (GRAVITY) C CHEMICAL DRAIN CD CHEMICAL FEED CF CHILLED WATER RETURN —CHWR— CHILLED WATER SUPPLY —CHWS— CLD CLEAR WATER DRAIN COOLING WATER RETURN —CLWR— COOLING WATER SUPPLY —CLWS— CORROSION RESISTANT VENT CRV CRW CORROSION RESISTANT WASTE COOLING TOWER FILTER RETURN —CTFR— COOLING TOWER FILTER SUPPLY — CTFS — CONDENSER WATER RETURN CWR CONDENSER WATER SUPPLY CWS DOMESTIC COLD WATER CW DRAIN D DEIONIZED WATER DI DISTILLED WATER DW FIRE LINE, AHEAD OF ALARM VALVE F FIRE HOSE CABINET PIPING FH FUEL OIL RETURN FOR FUEL OIL SUPPLY FOS FUEL OIL VENT FOV FILTERED WATER FW G NATURAL GAS CONDENSATE, STEAM (HIGH PRESSURE) HPC CONDENSATE RETURN (HIGH PRESSURE) HPR STEAM SUPPLY (HIGH PRESS, 125-250 PSIG) HPS HEAT PUMP WATER SUPPLY —HPWS— HEAT PUMP WATER RETURN —HPWR— HEAT RECOVERY SUPPLY HRS HEAT RECOVERY RETURN HRR DOMESTIC HOT WATER SUPPLY HW DOMESTIC HOT WATER CIRCULATING HWC HEATING WATER RETURN HWR HEATING WATER SUPPLY HWS INSTRUMENT AIR IA INDIRECT DRAIN ID INDUSTRIAL WASTE IW LIQUID NITROGEN LN2 CONDENSATE, STEAM (LOW PRESSURE) LPC LIQUID PETROLEUM GAS LPG STEAM SUPPLY (LOW PRESS, 0-15 PSIG) LPS CONDENSATE, STEAM (MEDIUM PRESSURE) MPC STEAM SUPPLY (MEDIUM PRESS, 15-125 PSIG) MPS OVERFLOW DRAIN OFD PROCESS COOLING WATER SOURCE —PCWS— PROCESS COOLING WATER RETURN —PCWR— CONDENSATE RETURN (PUMPED) PR PIPE IDENTIFICATION SYMBOL DESCRIPTION PROCESS WATER PW ROOF DRAIN RD REFRIGERANT DISCHARGE RDS REFRIGERANT HOT GAS RHG REFRIGERANT LIQUID RL REFRIGERANT SUCTION (GAS) RS RAIN WATER LEADER RWL SPRINKLER LINE S SANITARY WASTE ABOVE GRADE OR FLOOR SAN --SAN-- SANITARY WASTE BELOW GRADE OR FLOOR SUMP PUMP DISCHARGE SPD STEAM SUPPLY STM --STS-- STORM DRAIN BELOW GRADE OR FLOOR ----TP---- TRAP PRIMER VENT V VACUUM VAC VACUUM PUMP DISCHARGE VPD PIPE FITTINGS SYMBOL DESCRIPTION BELL & SPIGOT ) ) BLIND FLANGE �1 BUSHING ► EXPANSION JOINT —IN-- FLANGED FITTING -I F- FLEXIBLE PIPE CONNECTION :•:❖; HOSE BIBB B HOSE BIBB - NON FREEZE 'HB PIPE ANCHOR X PIPE CAP SCREWED OR SOLDER JOINT PIPE CAP, WELDED OR GROOVED D PIPE CROSS PIPE ELBOW, 90° SHORT RADIUS _,}sR PIPE ELBOW, 90° LONG RADIUS —} —1 PIPE ELBOW, REDUCING PIPE ELBOW, 45° —'N PIPE ELBOW, TURNED UP OR TOWARD —'0 PIPE ELBOW, TURNED DOWN OR AWAY 3 PIPE GUIDE PIPE HANGER / x Y PIPING MATERIAL CHANGE, X TO Y I PIPE PLUG —tea PIPE REDUCER CONCENTRIC —c, b PIPE REDUCER ECCENTRIC ' PIPE SUPPORT PIPE TEE, STRAIGHT 1 PIPE TEE, UP OR TOWARD —ND PIPE TEE, DOWN OR AWAY 'Ci SCREWED FITTING OR AS SPECIFIED 1 I SEISMIC HANGER /S SEISMIC LOOP A E-- SOLDERED FITTING PIPE FITTINGS SYMBOL DESCRIPTION SOLVENT CEMENT 9 SPRING HANGER UNION, FLANGED --�I--- UNION, SCREWED 1�— WELDED FITTING HOSE KIT —ICI— PIPING SPECIALTIES SYMBOL DESCRIPTION A 2 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR 3 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR It] 0 / 0 AIR DROP - HOSE, SIMPLEX / DUPLEX e / ® AIR OUTLET - HARD PIPE, SIMPLEX / DUPLEX CS ANGLE GLOBE VALVE, ELEVATION / PLAN 400 AUTOMATIC FLOW CONTROL VALVE (NUMBER INDICATES GPM) PM -AAv AUTOMATIC AIR VENT (WITH DRAIN) BACKFLOW PREVENTER BFP - BALANCE VALVE WITH METERING PORTS BALANCE VALVE W/0 METERING PORTS -1141-1•f- BALL VALVE, OPEN / CLOSED BUTTERFLY VALVE .I— COOLING COIL CHILLED WATER FLOAT VALVE 1 4q FLOWMETER, VENTURI TYPE a 1 FLOWMETER ORIFICE ---� I— ->a--/ ISOLATION VALVE, OPEN / CLOSE A GATE VALVE, OUTSIDE SCREW AND YOKE GATE VALVE, WITH HOSE CONNECTION --oil -D31-/ GLOBE VALVE, OPEN / CLOSED HEATING COIL -L 1-/ $ LIFT CHECK VALVE -MAV MANUAL AIR VENT (WITH DRAIN) © MOTOR OPERATED VALVE .41 NEEDLE VALVE Q NITROGEN DROP O NITROGEN OUTLET PETCOCK k HOFE PETE'S PLUG, WITH BALL VALVE SF-- PLUG VALVE/STOP COCK 1-11•10 PRESSURE GAUGE WITH VALVE PRESSURE REGULATING VALVE W/EXT PRESS TAP All : PRESSURE REGULATING VALVE (SELF CONTAINED) , 20 PRESSURE RELIEF VALVE / SAFETY VALVE QUICK OPENING VALVE QUICK CLOSING VALVE, FUSIBLE LINK A SOLENOID OPERATED VALVE STEAM TRAP o SWING CHECK VALVE WITH FLOW -- --- Xi GAS PRESSURE REGULATOR PIPING SPECIALTIES SYMBOL DESCRIPTION A TEST PLUG IiI THERMOMETER, LINE MOUNT �f THERMOMETER, SEPARABLE WELL MOUNT T TRAP, FLOAT TRAP SEAL PRIMER VALVE TP UNCLASSIFIED VALVE v-1 A VACUUM DROP (LAB VAC) 0 VACUUM OUTLET (LAB VAC) HARD PIPED v VACUUM CLEANING OUTLET O VALVE BOX -KC I— VALVE IN RISER (TYPE SPECIFIED) WATER HAMMER ARRESTOR WYE STRAINER (WITH DRAIN VALVE) I yi FIRE PROTECTION SYMBOL DESCRIPTION ALv ALARM VALVE, WET % AUTOMATIC SPRINKLER RISER ICI DRY PIPE VALVE ELECTRIC BELL EXISTING SPRINKLER HEADS (TO REMAIN) EXISTING SPRINKLER HEADS (REMOVE) X FIRE HOSE CABINET FHC FDC FIRE DEPARTMENT CONNECTION, WALL TYPE . :DC le FIRE DEPARTMENT CONNECTION, YARD TYPE FDC FIRE DEPARTMENT CONNECTION, FLUSH LJ ni FIRE HYDRANT - 2 HOSE OUTLET FH FIRE HYDRANT - 2 HOSE OUTLET AND PUMPER CONNECTION FLOW SWITCH Fs 4:15.4 GROOVED COUPLING, GROOVED CAP MONITOR SWITCH M PIV POST INDICATOR VALVE, YARD SPRINKLER HEAD, DRY PENDENT SPRINKLER HEAD, OVER AND UNDER • SPRINKLER HEAD, PENDENT, IN LINE, NEW SPRINKLER HEAD, PENDENT, OFFSET, NEW —101— SPRINKLER HEAD, SIDEWALL, PENDENT, NEW v SPRINKLER HEAD, SIDEWALL, UPRIGHT, NEW SPRINKLER HEAD, UPRIGHT, NEW —O THRUST BLOCK rlv io_x WALL INDICATOR VALVE, PLAN / ELEVATION WMG WATER MOTOR GONG ® GAS METER ® WATER METER WELDING SYMBOL DESCRIPTION ROOT DEPTH FOR SLOT EFFECTIVE THROAT SIZE STRENGTH CERTAIN OPENING OF PLUG WELDS OR ((jel FILLING AND FOR WELDS T CONTOUR SYMBOL FINISH SYMBOL F f GROOVE ANGLE, INCLUDED ANGLE OF COUNTERSINK FOR PLUGWELD LENGTH OF WELD PITCH (CENTER TO CENTER SPACING) OF WELDS FIELD WELD SYMBOL ARROW ING REFERENCE LINE TO ARROW SIDE A R S E) { LA' gg L Wg}L-P L. BASIC DETAIL TAIL REFERENCE SPECIFICATIONS, OR m N} { i ( \ ) ELEMENTS IN THIS AREA REMAIN AS SHOWN WHEN TAIL AND ARROW ARE REVERSED - OR ARROW SIDE MEMBER OF JOINT WELD ALL AROUND SYMBOL REFERENCE LINE NUMBER OF SPOT OR PROJECTION WELDS WELD SYMBOL OR REFERENCE (MAY BE OMMITTED WHEN IS NOT USED PROCESS OTHER REFERENCE p BACK WELD L FILLET WELD PLUG OR SLOT WELD NNE (I SQUARE WELD O SPOT OR PROJECTION WELD REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 2 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 19.: 2015 PERMIT CENTER ro RFFFH FACILITY DESIGN BY WH \C O\L DATE 07.08.15 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 9-120 STATION 5 AHU REPLACEMENTS 21067 WH MBL 04.07.15 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE LEGEND AND ABBREVIATIONS CURRENT REVISION 21067 SYMBOL DATE 04.07.15 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED TITLE 9-120 STATION 5 AHU REPLACEMENTS BUILDING 9-120 SHEET M1C JOB NO. 21067 COMP NO. , , I DWG NO. DABENOJA: 06/04/15 APPROVED GE\RAL \OTES: 1. THE FOLLOWING NOTES APPLY TO ALL MECHANICAL DRAWINGS. ADDITIONAL NOTES MAY BE INDICATED ON INDIVIDUAL DRAWINGS. 2. DRAWINGS INDICATE CONNECTIONS FOR EQUIPMENT TO BE FURNISHED BY THE OWNER OR AS THE WORK OF OTHER TRADES. VERIFY LOCATION OF EQUIPMENT, ROUGH -IN LOCATIONS, AND TYPE OF CONNECTIONS PRIOR TO PREPARATION OF SHOP DRAWINGS OR SUBMITTALS, AND PRIOR TO INSTALLATION OF SERVICE CONNECTIONS. DO NOT INTERFERE WITH ACCESS FOR MAINTENANCE AND REMOVAL OR REPLACEMENT OF EQUIPMENT. 3. COORDINATE THE PHASING AND INSTALLATION OF NEW WORK WITH THE WORK OF ALL OTHER TRADES. THE CONTRACTOR SHALL BEAR THE TOTAL EXPENSE FOR ANY ADDITIONAL WORK WHICH MAY BE CAUSED BY IMPROPER SEQUENCING OF CONSTRUCTION ACTIVITIES. 4. REFER TO ARCHITECTURAL DRAWINGS FOR ELEVATIONS OF DEVICES IN FINISHED AREAS. LOCATE PLUMBING FIXTURES AT HEIGHTS INDICATED ON ARCHITECTURAL ELEVATIONS. LOCATE MECHANICAL DEVICES (E.G. TEMPERATURE AND HUMIDITY SENSORS, PANELS, AND SWITCHES), SO THAT THEY DO NOT CONFLICT WITH GENERAL CONSTRUCTION (E.G. WAINSCOT, DOOR HARDWARE), ELECTRICAL DEVICES (E.G. LIGHT SWITCHES, SPEAKERS, OUTLETS), AND THE WORK OF OTHER TRADES. 5. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL CONSTRUCTION INCLUDING, BUT NOT LIMITED TO, EQUIPMENT HOUSEKEEPING PADS, PENETRATION DETAILS, FLASHING AND SEALING DETAILS, AND OTHER ELEMENTS OF GENERAL CONSTRUCTION. COORDINATE THE SIZE AND LOCATION OF EQUIPMENT HOUSEKEEPING PADS WITH APPROVED EQUIPMENT SO THAT HOUSEKEEPING PADS ARE NOMINALLY 7" HIGH UNLESS INDICATED OTHERWISE, AND EXTEND 6" MINIMUM IN ALL DIRECTIONS FROM THE HORIZONTAL LIMITS OF THE EQUIPMENT WHICH THEY SUPPORT. 6. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF CEILING MOUNTED ITEMS. INSTALL CEILING MOUNTED ITEMS IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE INDICATED ON ARCHITECTURAL DRAWINGS. WHERE LOCATION OF ITEMS ARE NOT INDICATED ON ARCHITECTURAL DRAWINGS, OBTAIN DIRECTION FROM ARCHITECT PRIOR TO ROUGH -IN AND INSTALLATION. 7. MECHANICAL DRAWINGS SHOW APPROXIMATE LOCATIONS FOR FLOOR DRAINS. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS. IN MECHANICAL EQUIPMENT AREAS, COORDINATE THE LOCATIONS OF FLOOR DRAINS WITH THE ACTUAL COORDINATED HOUSEKEEPING PAD LOCATIONS AND MECHANICAL EQUIPMENT DRAIN LOCATIONS. WHERE NECESSARY TO PROVIDE THE VERTICAL HEIGHT NECESSARY FOR DEEP SEAL CONDENSATE TRAPS, PROVIDE MECHANICAL EQUIPMENT SUPPORTS AS REQUIRED TO RAISE THE EQUIPMENT SUFFICIENTLY TO ALLOW TRAP INSTALLATION WITHOUT FLOOR PENETRATION. MECHANICAL EQUIPMENT SUPPORTS SHALL CONFORM TO SEISMIC RESTRAINT REQUIREMENTS AND SHALL MEET ALL SEISMIC DESIGN AND CODE REQUIREMENTS. 8. COORDINATE EQUIPMENT POWER CONNECTION REQUIREMENTS AND ELECTRICAL CHARACTERISTICS WITH ELECTRICAL DRAWINGS AND CONNECTION REQUIREMENTS. COORDINATE VARIATION IN ELECTRICAL CHARACTERISTICS FROM SCHEDULED VALUES. CHANGES TO ELECTRICAL CHARACTERISTICS (E.G. VOLTAGE, AMPS, HORSEPOWER, ETC.) SHALL BE SUBJECT TO APPROVAL. BEAR THE TOTAL EXPENSE FOR REQUIRED REVISION TO THE ELECTRICAL SCOPE OF WORK CAUSED BY VARIATION FROM THE SCHEDULED REQUIREMENTS. 9. COORDINATE THE LOCATION OF WORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES AND OTHER CEILING MOUNTED DEVICES AS REQUIRED TO ALLOW FOR REMOVAL AND MAINTENANCE ACCESS. 10. DO NOT RESTRICT ACCESS TO ELECTRICAL CABLE TRAYS. AT A MINIMUM, ALLOW 18" CLEAR ON ONE SIDE OF CABLE TRAYS UP TO AN ELEVATION OF 6" ABOVE THE TOP OF THE CABLE TRAY. MAINTAIN 12" MINIMUM CLEARANCE OVER TOP OF CABLE TRAYS EXCEPT WHERE DUCT, PIPING, OR CONDUIT CROSS PERPENDICULAR TO CABLE TRAY, THIS CLEARANCE MAY BE REDUCED TO 6" OVER A DISTANCE OF NO MORE THAN 36" ALONG THE CABLE TRAY. PROVIDE NO LESS THAN 36" BETWEEN AREAS OF REDUCED CLEARANCE AND MAINTAIN INDICATED ACCESS ON THE SAME SIDE OF THE CABLE TRAY EXCEPT WHERE OTHERWISE APPROVED. DO NOT CONNECT OTHER TRADE ITEMS TO CABLE TRAYS, CABLE TRAY SUPPORTS OR CABLE TRAY SEISMIC RESTRAINTS. 11. PROVIDE SUPPORTS AND SEISMIC RESTRAINTS FOR PIPES, DUCTS, AND EQUIPMENT AS SPECIFIED, AS REQUIRED, AND AS SHOWN ON THE DRAWINGS. IF REQUIRED FOR INSTALLATION OF PIPES, DUCTS, AND EQUIPMENT, DESIGN AND PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAME TO MEET SUPPORT AND SEISMIC RESTRAINT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS AND ANCHORAGES SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED. REFER TO STRUCTURAL DRAWINGS FOR DESIGN CRITERIA. SUBMIT STRUCTURAL MEMBER SHOP DRAWINGS AND CALCULATIONS FOR REVIEW. STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS SHOWN ON THE STRUCTURAL DRAWINGS AND INDICATED IN THE SPECIFICATIONS. NO WELDING, BOLTING, OR OTHER MEANS OF ATTACHMENT TO THE STRUCTURAL MEMBERS SHALL BE MADE ON PORTIONS OF STRUCTURAL MEMBERS AT OR NEAR CONNECTIONS BETWEEN STRUCTURAL MEMBERS ON ANY ELEMENTS DESIGNATED IN THE SEISMIC LOAD RESISTING SYSTEMS UNLESS APPROVED BY THE STRUCTURAL ENGINEER. SUPPORTS SHALL NOT INDUCE TORSIONAL LOADS INTO SUPPORTING STRUCTURAL FRAMING. 12. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS OR SHEAR WALLS UNLESS INDICATED ON STRUCTURAL DRAWINGS OR AS APPROVED BY THE STRUCTURAL ENGINEER. 13. PROVIDE PIPE SLEEVES AND PENETRATION SEALS AS REQUIRED FOR THE INSTALLATION OF PIPING SYSTEMS. REFER TO SPECIFICATIONS FOR REQUIREMENTS. 14. COORDINATE THE LAYOUT OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES SO THAT IT FITS INTO THE SPACE ALLOTTED. PROVIDE SERVICE ACCESS AND CLEARANCES AS INDICATED ON DRAWINGS, AS REQUIRED BY CODES, AND AS RECOMMENDED BY THE MANUFACTURER FOR THE INSTALLATION, REMOVAL, ENTRY, SERVICING, AND MAINTENANCE OF EQUIPMENT. PRIOR TO INSTALLATION, COORDINATE LAYOUT OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES WITH ALL OTHER TRADES TO AVOID BLOCKING SERVICE OR REPLACEMENT ACCESS FOR NEW AND EXISTING EQUIPMENT AND EQUIPMENT INSTALLED BY OTHERS. 15. DRAWINGS ARE DIAGRAMMATIC AND SHOW APPROXIMATE LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES. DRAWINGS DO NOT SHOW REQUIRED TRANSITIONS, OFFSETS, FITTINGS, AND DEVICES. REFER TO DETAILS, DIAGRAMS, AND SPECIFICATIONS FOR REQUIRED SYSTEM APPURTENANCES, CONTROL DEVICES, ETC. INSTALL DEVICES IN ACCORDANCE WITH DEVICE MANUFACTURER RECOMMENDATIONS. CAREFULLY INVESTIGATE ELEMENTS OF CONSTRUCTION THAT COULD AFFECT THE WORK TO BE PERFORMED AND ARRANGE NEW WORK ACCORDINGLY. PREPARE COORDINATION DRAWINGS FOR NEW WORK, WHICH ARE COORDINATED WITH THE APPROVED AND INSTALLED WORK OF OTHER TRADES. PROVIDE REQUIRED OFFSETS, FITTINGS, TRANSITIONS, SUPPORTS AND OTHER APPURTENANCES AS REQUIRED. BEAR THE TOTAL EXPENSE OF RE -WORK THAT IS CAUSED BY FAILURE TO COORDINATE. 16. PROVIDE MAXIMUM HEADROOM AND CLEARANCE BELOW DUCTWORK, PIPING AND EQUIPMENT AND ASSOCIATED SUPPORTS AND RESTRAINTS. UNLESS OTHERWISE INDICATED, INSTALL TIGHT TO STRUCTURAL SYSTEMS ABOVE. WHERE WALL MOUNTED, INSTALL AS CLOSE TO WALL AS POSSIBLE. PROVIDE ADDITIONAL FITTINGS AND OFFSETS AS REQUIRED. 17. REFER TO EQUIPMENT SCHEDULES FOR DESIGN CAPACITIES. SCHEDULED VALUES SHALL BE CONSIDERED DESIGN CAPACITIES. PROVIDE EQUIPMENT WHICH MEETS OR EXCEEDS THE SCHEDULED VALUES. MARK THE CONTRACT DRAWING EQUIPMENT SCHEDULES TO INDICATE THE MANUFACTURER, MODEL AND CAPACITY OF THE ACTUAL APPROVED EQUIPMENT PROVIDED AND SUBMIT THIS INFORMATION WITH RECORD DRAWINGS AS PART OF PROJECT CLOSEOUT. 18. TO ENHANCE THE CLARITY OF PLAN DRAWINGS, AND WHERE NOT NECESSARY TO DESCRIBE THE REQUIRED SIZE, INDIVIDUAL SEGMENTS OF DUCT AND PIPE BETWEEN CONNECTIONS MAY BE SHOWN WITHOUT A SIZE INDICATED. WHERE SIZE IS NOT SHOWN ON PLANS, THAT SEGMENT SHALL BE THE SAME SIZE AS THE NEXT UPSTREAM SEGMENT WITH A SIZE INDICATED. 19. WHERE NOT INDICATED ON PLANS, REFER TO EQUIPMENT SCHEDULES AND DETAILS FOR INLET AND OUTLET DUCT AND/OR PIPE SIZES. WHERE INDICATED ON PLANS, PLAN SIZES SHALL TAKE PRECEDENCE. 20. DUCTWORK SERVING INDIVIDUAL DIFFUSERS AND GRILLES IS GENERALLY NOT SIZED. WHERE NOT INDICATED ON PLAN DRAWINGS, REFER TO SCHEDULES AND DETAILS FOR NECK AND BRANCH DUCT SIZES BASED ON INDICATED AIRFLOW RATE OR NECK SIZE. 21. INSTALL DRAINS AT ALL LOW POINTS IN PIPING, INCLUDING ANY TRAPPED PORTIONS OF PIPING. PROVIDE MANUAL AIR VENTS AT ALL HIGH POINTS IN CLOSED LOOP (MECHANICAL) PIPING SYSTEMS. IN GENERAL, THESE DEVICES ARE NOT INDICATED ON DRAWINGS. WHERE AUTOMATIC AIR VENTS ARE INDICATED ON DRAWINGS, EXTEND AUTOMATIC AIR VENT (AAV) DISCHARGE TO NEAREST FLOOR DRAIN USING INDIRECT DRAIN PIPING OF SAME SIZE AS AAV DISCHARGE. INDICATE THE ACTUAL LOCATION OF FIELD -LOCATED DRAINS, VENTS AND DRAIN PIPING ON THE RECORD DRAWINGS. 22. PROVIDE A MANUAL VOLUME DAMPER FOR EACH SUPPLY, RETURN, AND EXHAUST OPENING, IN ALL BRANCH DUCTS WHERE THREE OR MORE OPENINGS ARE ASSOCIATED WITH BRANCH, AND ELSEWHERE AS NOTED ON DRAWINGS OR IN SPECIFICATIONS. LOCATE VOLUME DAMPERS AS FAR AS POSSIBLE FROM OPENINGS. FOR THE PURPOSE OF THIS REQUIREMENT, TERMINAL UNIT PRIMARY AIR DAMPERS ARE CONSIDERED A VOLUME DAMPER. VOLUME DAMPERS ARE NOT REQUIRED FOR CEILING RETURN GRILLES THAT TRANSFER AIR TO A RETURN AIR PLENUM UNLESS OTHERWISE INDICATED. 23. PROVIDE CONICAL TAPS FOR 90 DEGREE ROUND DUCT BRANCHES FROM RECTANGULAR SUPPLY DUCTWORK DOWNSTREAM OF TERMINAL UNITS. USE LOW LOSS OR HEEL TAP FITTINGS ON ALL 90 DEGREE BEND ROUND BRANCHES UPSTREAM OF TERMINAL UNITS. DO NOT USE STRAIGHT TEE FITTINGS UNLESS SPECIFICALLY INDICATED ON DRAWINGS. 24. DUCTWORK STATIC PRESSURE AND SEAL CLASS, BASED ON SMACNA HDCS: DUCT SYSTEM A. DOWNSTREAM OF AH1F1 B. DOWNSTREAM OF AH1G1 C. UPSTREAM OF AH1F1 D. UPSTREAM OF AH1G1 E. OUTSIDE AIR INTAKE DUCTS STATIC PRESSURE +3 IN, WG +2 IN WG -3 IN WG -2 IN WG -2 IN WG SEAL CLASS A A A A A 25. PROVIDE DUCT LINING FOR DUCTWORK AND PLENUMS AS SPECIFIED, WHERE INDICATED DN DRAWINGS AND AS INDICATED BELOW. DUCT SIZES INDICATED ON DRAWINGS ARE NET INSIDE DIMENSIONS REPRESENTING THE MINIMUM DUCT FREE AREA. THICKNESS OF DUCT LINING SHALL BE AS SPECIFIED UNLESS A GREATER THICKNESS IS INDICATED ON DRAWINGS. FOR CLARITY, DUCT LINING MAY NOT BE SHOWN IN ALL REQUIRED LOCATIONS ON DRAWINGS. PROVIDE DUCT LINING FOR THE FOLLOWING: A. ROUND AND RECTANGULAR SUPPLY AIR DUCTWORK AND PLENUMS. B. ROUND AND RECTANGULAR RETURN AIR DUCTWORK AND PLENUMS. C. AIR TRANSFER DUCTS. 26. THE FOLLOWING IS A LIST OF DEFERRED SUBMITTALS ITEMS. DO NOT INSTALL DEFERRED SUBMITTAL ITEMS UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. A. FIRE PROTECTION SYSTEMS. B. MECHANICAL SEISMIC. 27. MOTORIZED DAMPERS SHALL BE PROVIDED FOR OUTDOOR AIR SUPPLY, EXHAUST OPENINGS. DAMPER CONSTRUCTION SHALL IN ACCORDANCE WITH WSEC SECTION C402.4.5.2 & C403.2.4 28. DUCTWORK AND PLENUMS SHALL BE SEALED IN ACCORDANCE WITH WSEC SECTIONS C403.2.7.1, C403.2.7.3 AND SPECIFICATION SECTION 23 30 00 HVAC AIR DISTRIBUTION. 29. DUCTWORK AND PLENUMS SHALL BE INSULATED IN ACCORDANCE WITH WSEC SECTION C403.2.7.1/2. AND SPECIFICATION SECTION 20 70 00 INSULATION FOR PLUMBING AND HVAC. 30. PIPING SHALL BE INSULATED IN ACCORDANCE WITH WSEC SECTION C403.2.8, WASHINGTON STATE PLUMBING CODE (WAC 51-56) AND SPECIFICATION SECTION 20 70 00 INSULATION FOR PLUMBING AND HVAC. PIPING INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE PER WSEC SECTION C403.2.8.1 AND SPECIFICATION SECTION 20 70 00 INSULATION FOR PLUMBING AND HVAC. 31. EQUIPMENT SHORT CIRCUIT CURRENT RATING (SCCR) SHALL BE NOT LESS THAN THE INTERRUPTING RATING OF THE BRANCH CIRCUIT OVERCURRENT PROTECTIVE DEVICE SUPPLYING POWER TO THE EQUIPMENT. REFER TO ELECTRICAL SCHEDULES FOR BRANCH CIRCUIT OVERCURRENT DEVICE INTERRUPTION RATINGS. 32. cock, Eg rau ?� rZ (MG ctPt/ G r!'e t.t .S'4411-C N f 4 s 11/4twia-ems . LEGE\D 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M2C AND M1C. GE\FAL \OTES GENERAL NOTES ON THIS SHEET SHALL APPLY TO ALL NEW CONSTRUCTION EFEH \CE DAWI\GS C O \ STD U CTI O \ \OTES REVIEWED FOR CODE COMPLIANCE APPROVED DEC 022015 City of Tukwila BUILDING DIVISION • RECEIVED CITY OF TUKWILA NOV 19, 2015 PERMIT CENTER FOR HFFPE\C FACILITY DESIGN BY WH OLY DATE 07.08.15 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 9-120 STATION 5 AHU REPLACEMENTS 21067 WH MBL 04.07.15 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE MECHANICAL GENERAL NOTES CURRENT REVISION 26032-01 SYMBOL DATE 04.07.15 ENGINEER SHEET APPROVED BY DEPT. DATE CHECKED APPROVED APPROVED TITLE 9-120 STATION 5 AHU REPLACEMENTS I Irnl 111 II n 11 1 1 A n 1-1- BUILDING 9-120 M2D JOB NO. 21067 COMP NO. nr1 , nr1 rrrr'\ 1,111 DWG NO. L -GE\D Po ® POINT OF CONNECTION _- -t- FLEXIBLE DUCT WITH VOLUME DAMPER R.A. 26/16 ZONE 1 SEE ENLARGED PLAN I 1 1M11 M450 Oven 81 "x48" c`r O co 00 0mX ,,0 2 La r Oven 81 "x48" ProcessTable 1000 CFM, 6aRx1' 13/20 18/24 24/20 s POC 24/12 CD \R3E£ ES 10 12/12 SR SHO 1-7 25/24 DR AP Sc RACK SANDBLAST u Large Steel Table 48x30 T.G., CAPPED RG-48x24 5280 CFM Janet Table POC On Whee 3 /24 250 CFM, SG-10x6, TYP 2 DROP 24" DRIDGEKRT a nawO Z4 POC 22/12 17/12 BOT. OF DUCT 15-0" A.F.F. (ELEV.30'-6") 4"EA —7 a / IISTA NSES 1 1 7i F POC, TYP / II' 600 CFM 595 CFM /24 48x30 T.G., CAPPED BOD 13'-6" AFFI 4 4/ U J BE c 36X7: 2 RG-24x24 380 CFM Ja rCO (b ' m 1.1 O U o 10 /SR \10 240 CFM I` z W m 12 330 CFM T— 2 2/10- 12/10 55,9' LAYUP TEL EYE W 0 CFM SR TYP.OF�12 \ / TUBE TORAGE & LAY L 12/10 2 5'x9' LAYUP TBL 330 CFM 12/10 ao� o 11 35) 1350 TA.E LE 30XE0 m -7 n = U z w CO CID N) m n U z w m N X X M 1E) IOLLING ART BOD 1 2.6" STORAGE & LAYUP TBL F 970 CFM 30/10 TYP. OF I 32/12 IS TYP. OF 43ENCH1 ROLLING CART 36X72 OF/ ROLLING CART CO m z = U z w CO N M co m z W X J I 14/18 9 7 N ELECT. PANEL 130 CFM D-115 135 CFM D-115� Y !MOH SDI 14/12 BEAD EUST 4"EA - 4D NAKF LP 1JPPLY AIR 1 1 RG-1520 D N UP 400 CFM D-116 120 ♦'EREWOUf(N f z nc1, EYE GRILLE FLCO DLA\ SCALE: 1 /8"=1'-0" N co N) 3'-6" CLEAR 8'-8" B.O.D. 28/10 UP 60/18 120 EXHAUST TO ROOF WITH RAIN COLLAR 3 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE K REPLACE UNIT SUBSTATION 11 23904 WH MBL 04.07.15 F CANCELLED 55613204 HARR RWS 2006 L 9-120 STATION 5 AHU REPLACEMENTS 21067 WH MBL 04.07.15 G REV DUST COLL. IN BREAKOUT ROOM 57576000 HARR RWS 04/06/07 c INSTALL PLANER J3701746-00 DMV 06.22.00 H SURPLUS HAMILTON FUME HOOD 4207457 HARR 06/13/07 D RELOCATE DUST COLLECTION FOR SINTERING 55613200 HARR RWS 08/05/05 RELOCATED INDUSTRIAL VAC & DUST COL. TO DWG. 1M361 S.RUDELL 05.22.08 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN M.DITTMAR DATE 11.10.94 24/12 RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN. ROUND DUCT, NUMBER INDICATES DIAMETER 240 240 J SUPPLY OUTLET 340 A /CFM 100/ V —00 AIR DIFFUSER/REGISTAR/GRILL. REFER TO SHEET M1A. 2—WAY EARTHQUAKE BRACING, SEE 1M11 M504 4—WAY EARTHQUAKE BRACING, SEE 1M11 M504 INDICATES GCU DASH NUMBER FOR WORK TASK. OTHERS INDICATES OUTSIDE CONTRACTOR CONSTRUCTION FLAGNOTE. GE\EAL \OTES 1. ALL NEW DUCTWORK IS TO BE FABRICATED PER DETAIL 1M11 M502 SPARE DIFFERENTIAL PRESSURE SENSOR, ANCHOR TO BOTH SIDES OF WALL. HFEH\CE D SAW 1 GS REF. DRAWINGS : 6130D-120-212, 6130D-120-202, 109-120-4114 CO \ST UCTIO\ \OTES REMOVE EXISTING CEILING DIFFUSER AND PROVIDE NEW CDA DIFFUSER, BALANCE TO AIRFLOW INDICATED. ADJUST AIRFLOW FOR CEILING DIFFUSER/GRILLE TO AIRFLOW INDICATED. TYPICAL ALL DIFFUSERS AND GRILLES FOR AH1G1 AND AH1F1. 3. CLEAN ALL SUPPLY AIR DUCTWORK, RETURN AIR DUCTWORK, GRILLES, DIFFUSERS AND ALL APPURTENANCES ASSOCIATED WITH AH1F1 AND AH1G1. REMOVE EXISTING SG AND PROVIDE NEW SG. 5. FOR TYPICAL GRILLE REGISTER DIFFUSER INSTALLATION DETAIL SEE DETAIL 1M1 M539 BLANK OFF EXISTING TRANSFER AIR GRILLE. 7. COORDINATE WITH BOEING FACILITIES DEPARTMENT FOR ANY REMOVAL OR HANDLING OF ASBESTOS CONTAINING MATERIAL INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. 8> PROVIDE 48X24 RG WITH RETURN AIR DUCT AS SHOWN REAVVED FOR om COMPLIANCE 4. APPROVED DEC 0 2 2015 City of Tukwila BUILDING DIVISION 1M10 1M12 1M13 RECEIVED CITY OF 'TUKWILA NOV 19 2035 PERMIT: CENTER KEY PLAN (a) 0 O ® FOR R F FACILITY DESIGN BY WH \CEO \LY DATE 07.08.15 CHECKED SUBTITLE HVAC FIRST FLOOR PLAN CURRENT REVISION 21607 SYMBOL L DATE 04.07.15 ENGINEER S.ROSSE CHECKED APPROVED TITLE 9-120 STATION 5 AHU REPLACEMENTS BUILDING 9-120.1 SHEET 1M11 JOB NO. COMP NO. DABENOJA: 06/04/15 APPROVED DWG NO. LEGE\D AIR AMPLIFIER/DRYER FOR SINTERING MACH. 2"WASTE UP 125# PSI COMPRESSED AIR __ro 3/4"CA TO COL. E4 3/4" — HWC C 3/4'' w N 0 MATCHLINE - SEE CONTINUATION 3"V.T.R. ® 3" FUD SUBSTATION #10 125# PSI COMP. AIR EL 15-4" 3/4" 2" MOIRE TEST 134 94 SHOP 135 WORK ROOM FIST FLOOD PLU V D HPA 139 340 ' 3+9 FCO e-- 1/2' 1/2"A 1/2'A SUBSTATION #11 -0---CONDENSING UNIT GAS & LIQ. LINE 2"WASTE & VENT FOR IR COND. UNITS FREEZER STRAIN GAUGE 3/4"A 141 3/4'A PLUGGED FUD COND. PJMP /4" P—TRAP (16H2 FCO O 2" SAN UP 1/2" 1/2" MATCHLINE -SEE CONTINUATION ON SHEET 1M113 31\G PLA\ SCALE: 1/8"= 1'-0" 4"VACUUM EXHAUST DN. 1 1/4" VENT LINES 1" GATE VALVE —.I 1i"0 VENT 3/4" 2-1/2" 4" REDUCING STATION (--(1,4LA 1-1/2" 3/4" 3" VENT--,) 3" FUD 3"WUPTOFIRE SPRINKLER DRAIN 1Y2"A UP TO 2ND FL. UP 2 PSI COMP. AIR PRV-300GPM ©100-70 PSI HWC CW /4„ V," DEWAR STATION W Y2"OD SS-304 UP TO 2ND FL. FUD Y„ 2 3"CW DN 2"GAS DN W/ VALVE IN RISER 4"AIR DNW VALVE IN RISER 2"V UP 3"V UP 2"ACID WASTE UP 1st F..R SINK 3 HFEH\cE HW CW A• H PA HWC STS SAN IW HOT WATER, DOMESTIC COLD WATER, DOMESTIC COMPRESSED AIR 125# HIGH PRESSURE COMPRESSED AIR HOT WATER CIRCULATING, DOMESTIC STORM DRAIN SANITARY WASTE INDUSTRIAL WASTE AR ACID RESISTANT WASTE CD — CONDENSATE DRAIN ----V--- VENT 0FCO L�J r'i r, L�J FD. FUD AIR OUTLET, HARD PIPE, DUPLEX AIR DROP - HOSE, DUPLEX FLOOR CLEAN OUT FLOOR DRAIN FUNNEL DRAIN 2-WAY EARTHQUAKE BRACING, SEE 4-WAY EARTHQUAKE BRACING, SEE POINT OF CONNECTION GE\EAL \OTES FOR TYPICAL CONDENSATE TRAP DETAIL, SEE 1M111 M539 1M111 M504 ,0 \SRUCTIO\ \OTES 1. COORDINATE WITH BOEING FACILITIES DEPARTMENT FOR ANY REMOVAL OR HANDLING OF ASBESTOS CONTAINING MATERIAL INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. PROVIDE COMPRESSED AIR PIPING AND DUPLEX AIR DROPS AS INDICATED. POINT OF CONNECTION TO EXISTING 3'A MAIN. FIELD VERIFY EXACT LOCATION. ERWED FOR LADE COMPLIANCE APPROVED DEC 0 2 2015 kt` City of Tukwila BUILDING DIVISION RECEIVED CITY OFT.UKWILA NOV 19 2015 PERMIT CENTER D'AWI\GS 6130-D-9-120-102 PLUMBING PLAN MYLAR DRAWING ISSUED FOR CONSTRUCTION JULY 8, 2015 ® 1M110 1M112 1M113 4 8' 16' SCALE: 1 /8"=1' f1 3oo9 lizth Ave NE, Suite ioo Bellevue WA 98004 425.628.6000 woodha rbingertom 0 od 0 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 9-120 RENOVATION J#16054201-02 COFFMAN M. SOTURA 07.12.07 S RELOCATE ACAL/ASIC LAB 12370682 M.WONG RWS 01.05.12 RECORD DRAWING J#16054201-02 COFFMAN M. SOTURA 06.16.08 T REPLACE UNIT SUBSTATION 11 23904 WH MBL 04.07.15 REMOVE DRINKING FOUNTAIN 6382422 HARR RWS 02.13.08 U 9-120 STATION 5 AHU REPLACEMENTS 21067 WH MBL 04.07.15 COMBINED DLR WITH OLD 1M111 S.RUDELL 07.24.08 V 9-120 STRAIN GAUGE OVEN 26032-01 WH MBL 07.08.15 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED APPROVED epppnwrn DATE SUBTITLE 05.23.07 05.23.07 TITLE FIRST FLOOR PLUMBING PLAN 9-120 STRAIN GAUGE OVEN BUILDING 9-120 CURRENT REVISION SYMBOL DATE 26032-01 U 07.08.15 SHEET JOB NO. OW, NO. 1M111 16054201-02 COMP NO. LEGE\D SYM REVISION FOR CON'T SEE DWG. 1M260 & SV-919 5" RISER UP 2ND FLOOR ROLL UP 45' 4" B/SLAB TO 4. FROM SV-919 BY 2" PLUG 45' UP, 4" B/SLAB TO . PIPE (3 PLCS) OVEN RO M " BOT. LAB T MOIRE TEST 1Y4 134 1Y APPROVED DATE SYM CAPPED REVISION BELOW DUCT SPK HEAD BELOW DUCT SPK HEAD FREEZER(WALK—IN)' MSS # SO039016960 IN GAUGE LAB 2 BY DN W/ 1" L.P. DRAIN 1'-6" BOT.SLAB TO EL. 30'- 1'-5" BOT.SLAB EL. 30'-10" 11'-0 APPROVED 2" STUB W/ 1" DN DATE A REMOVE TWO SPRINKLER HEADS J#765003—LO SPR 11.11.96 F CDC RELOC—STRAIN GAUGE LAB—PKG 6—SOUTH J#19670-10 WH MBL 02.17.14 B INSTALL ONE SPRINKLER HEAD J#524660-00 DMV 8.12.02 G REPLACE UNIT SUBSTATION 11 23904 WH MBL 04.07.15 C SHIELD ROOM MODS J#1001336909 C. HARRAH RWS 9.7.04 H 9-120 STATION 5 AHU REPLACEMENTS 21067 WH MBL 04.07.15 D 9-120 DRY SPRINKLER HEAD 8513493 M.WONG RWS 12.18.09 J 9-120—STRAIN GAUGE OVEN 26032-01 WH MBL 07.08.15 4" RISER 1'-9" BOT.SLAB TO Q EL. 30'-6" 2"PLUG 1Y2 -(1)- -Y - --`) - -c p 1 _I _I -t- - 1 1 DROP BRANCH LINES THRU MEZZ. FLR. TO BAR JOIST CAVITY & EXTEND PIPING HORIZ. IN CAVITY (4) PLCS 1'-5" BOT.SLAB TO EL. 30'-10" 7" BOT.SLAB TO CL. 7" BOT.SLAB TO CL. 6'' .. TO 4. EL. 30': 1Y 1Y4 1 7" BOT.S ' B L.P. DRAIN L.P. DRAIN Ti CL. r L.P. DRAIN i Ip AL 1 ' n. Ili 1"DRAIN 1 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. Y2" VALVED DRAIN DATE ENCLOSURE WITH DRY PIPE SPRINKLER RISERS: SV-9919 SV-9919A 8 4 0 --0— s (EXIST) STANDARD SPRINKLER, PENDANT (165° UNLESS OTHERWISE NOTED) (NEW) STANDARD SPRINKLER, PENDANT (165° UNLESS OTHERWISE NOTED) (EXIST) STANDARD SPRINKLER, UPRIGHT (165° UNLESS OTHERWISE NOTED) (NEW) STANDARD SPRINKLER, UPRIGHT (165° UNLESS OTHERWISE NOTED) SPRINKLER, SIDEWALL WET SPRINKLER PIPING, SIZE AND SLOPE TO LOW POINT DRAIN SPRINKLER RISER (ALARM VALVE OR UPPER FLOORS) WATER MOTOR GONG PIPE HANGER 2-WAY EARTHQUAKE BRACING 4-WAY EARTHQUAKE BRACING J GE\ PAL \OTES 1. NOTIFY BOEING FIRE DEPT. 24 HOURS PRIOR TO SHUTDOWN. AND IN ADVANCE OF DOING WORK (206) 655-7700. 2. FOR EARTHQUAKE BRACING USE 1" STEEL PIPE FOR BRACES UP TO 7'-0" LONG & 1 1/4" PIPE FOR BRACES 7'-1" TO 9'-0" LONG. FLATTEN AND DRILL ENDS FOR MOUNTING. 3. USE 1/2", 165D SPRINKLER HEADS (PENDANT OR UPRIGHT AS INDICATED, UNLESS NOTED OTHERWISE.) 4. SLOPE ALL PIPING AS INDICATED TO DRAIN BACK TO RISER OR TO LOW POINT DRAIN. 5. ALL MATERIALS & INSTALLATION SHALL CONFORM TO NFPA PAMPHLET 13 FOR ORDINARY HAZARD OCCUPANCY. 6. FOR REFLECTED CEILING PLAN SEE DRAWING NUMBER 7. CONNECT TO EXISTING CROSS MAINS WHERE INDICATED ONLY AFTER HYDROSTATIC TEST (200 PSI FOR 24 HOURS) HAS BEEN WITNESSED & APPROVED BY THE BOEING FIRE DEPT. 8 > 625°F OVEN SPRINKLER WITH ORDINARY HAZARD REVIEWED FOR CODE COMPLIA`' APPROVED DEC 0 2 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 19 2015 PERMIT; CENTER 4 SCALE: 1/8" = 1 ' -0" GROUP 2 DENSITY. CO\STRUCTIO\ \OT PROVIDE 625 DEG F SPRINKLER IN OVEN WITH HEAD GUARD. PROVIDE RETURN BEND ON DROP TO OVEN. CONNECT TO EXISTING DRY PIPE SYSTEM, SV-9919. MODIFY EXISTING WET PIPE SPRINKLER SYSTEM IN THIS AREA TO ACCOMMODATE INSTALLATION OF OVEN AND ASSOCIATED DUCTWORK. PROVIDE ADDITIONAL PIPING, FITTINGS, SPRINKLERS, SUPPORTS AND SEISMIC BRACING AS REQUIRED PER SPECIFICATION. 3 EXISTING RISER ENCLOSURE. 1 16 ISSUED FOR CONSTRUCTION JULY 8, 2015 DRAWN DATE SUBTITLE DITTMAR/PRETARE 11.10.04 CHECKED ENCINEER CHECKED DOUG. HAN APPROVED APPROVFF) TITLE 11.7.2008 FIRE PROTECTION PLAN VIEW 9-120 STRAIN GAUGE OVEN BUILDING 9-120.1 1M260 1M262 1M263 0 1M265 CURRENT REVISION SYMBOL SHEET JOB NO. DWG NO. 26032-01 1 M261 ge J DATE 3oog urth Ave NE, Suite i0o Bellevue WA 98004 425.628.6000 woodharbinger.com 07.08.15 COMP NO. SUBSTATION #10 SUBSTATION #11 1, SEE ENLARGED PLAN 1 15HP SPENCER 1M361 M456 3-1 /2" (TEMPORARY CONSTRUCTION DETAIL) 20HP SPENCER 11 TO SPENCER 3-1 /2" I - N 5" TORIT D.C. 1500 CFM 208 v 5 HP. SEE CONTINUATION ON SHEET 1 M360 Oven 81"x48" 1�3" 2 Oven 81 "x48" OVEN RO 1 F2 1 0M Proces EL.15'-4" VAC Large Oven 1.5F2 C) ALUM SCRAP RACK SANDBLAST ,,/-- 4"VAC C) Large 'Steel To APORT RP LAB 1 1 G21 PPED-T 3"VAC n-it Table lei /'8"VAC / dr1O 1V011d0 la}ndwo gAa USIA VISES §Nboo o.00 err' b B F --2 4" ABANDONED 4" ABANDONED OW' SDI .,BSMOUT 5111 1/8 VA J — STORAGE ff/D 9/Sr B)D 9ASI 1-1/4" MOIRE TEST 134 SHOP 135 WORK ROOM 136 0 z w co ore N CO 0 N CO N 0 r N -P CO 1 11 F4 LJ J < 0 Ur1 d BENCH 36X72 5'x9' LAYUP TBL TUBE STORAGE 6 LAYUP TBL 5'x9' LAYUP TBL 8" 0 TIED INTO 16x11 DUCT ABOVE FUME HOOD w J 0 BENCH 36X72 OS£ STRAIN GAUGE LAB 141 0 350 TABLE 30X60 t) ROLLING CART ROLLING CART (16H2) TUBE STORAGE A LAYUP TBL (16H3) ROLLING CART BENCH' 36X72 CO N m X w N m M (13H3) a UP J EYE WASH 11H4) —1/2" 12H4 MATCHLINE — SEE CONTINUATION ON SHEET V 1 UP 1f) 20" DISC SANDER ,-u 1, 11 363 11 5 11 \ 4" 8' 4' 6" 6"X9" VERTICAL 1 BAND SAW JOINER PLANER 0 4' 1M361 M529 TORIT DUST COLLECTOR 8' 16' SCALE: 1 /8"=1'-0" 5 LFGE\D GE\EAL \CTES NOT USED NOT USED ABANDONED DUCTWORK NOT USED '=FETE\CE NAWI\GS CC\ STUCTIO\ \OTES 1. COORDINATE WITH BOEING FACILITIES DEPARTMENT FOR ASBESTOS CONTAINING MATERIAL INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. RE , EWED FOR CODE COMPLIANCE APP OVER • DEC 0 2 2815 CrItyNG DIof VISila ION RECEIVED CITY OF TUKWILA NOV 19 2015 PERMIT CENTER ISSUED FOR CONSTRUCTION JULY 8, 2015 1M160 1M162 1M163 KEY PLAN Q r 0 A ar in eHdr1In' 3009 with Ave NE, Suite ioo Bellevue WA 98004 425.628.6000 woo dha rbi nger.com SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE INDUST. VAC RELOCATED FROM DWGS. 1 M 11 &1 M61 S.RUDELL 05.22.08 E CDC RELOC - PKG 6A NORTH - RFI 27 J#19670-10 WH MBL 06.11.14 A PROVIDE HK VAC PORT 10897801/9710861 HARR 07/21/10 F REPLACE UNIT SUBSTATION 11 23904 WH MBL 04.07.15 ;a ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN S.RUDELL CHECKED DATE 05.22.08 SUBTITLE INDUSTRIAL VENTILATION FIRST FLOOR PLAN CURRENT REVISION SYMBOL DATE 26032-01 G 07.08.15 APPROVED BY DEPT. DATE ENGINEER TITLE 9-120 STRAIN GAUGE OVEN SHEET 1 M361 B CDC RELOC-STRAIN GAUGE LAB-PKG 6-NORTH J#19670-10 WH MBL 02.17.14 G 9-120 STRAIN GAUGE OVEN 26032-01 WH MBL 07.08.15 C CDC RELOC- PKG 6-SOUTH - RFI-016 J#19670-10 WH MBL 03.11.14 n Annr►1r11111 nn nun rA 11n11T11 1114nr-in 411 tsr nn 4 &8714 tOMAL >` P l� CHECKED APPROVED APPROVED BUILDING 9-120 11rn11A A1)n Al 11 A nTrn inn! r 1/ /4 r JOB NO. COMP NO. nr-I 1 nrA lrrn 111A DWG NO. n inn 4117r4 LEGE \D OA LOUVER SLOPE TO LOUVER — CONNECTION 10"o 16x24 2" THK INSULATION M456 M542 8 14"0 UP 8"0 UP 10" o UP y I/ J 8"0 M456 A (SIMILAR) M456 1 M537 14"0 EXH EX DO 6" o OVEN EXHAUST UP UME HOOD ST DUCT DUCT, I• ALL, TYP v v EF 1 F2 SUBSTATION #10 REF) SUBSTATION #11 (REF) �PT� X�}K /EF\/ \iF3/ / 6" o OVEN / EXHAUST DUCT, DOUBLE WALL OVEN "7--14" 0 60"x30" FUME HOOD 1000 CFM OVEN COOL DOWN OUTSIDE AIR INTAKE OVEN ROOM 1 F21 E\LAGED PLA\ 16x24 OVEN COOL DOWN EXHAUST I\DUSTIAL VE \TI LATI O \ RPM LAB 1 G21 1 SCALE: 1 /4"=1'-0" iM311M456 ti i i / •1151-1,- EXIST 28x40 EXHAUST AIR LOUVER 7-28x40 SLOPE TO LOUVER CONNECTION 2" THK INSULATION M456 M542 M456 M542 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M2C, M 1 C, AND M 1 E. GE\E AL \OTES CONICAL HOOD OVER OVEN EXHAUST PORT. DUCT EXHAUST UP TO ROOF WITH DRAIN AT BOTTOM OF RISER. 7 FEET BEYOND ROOF LEVEL. FUME EXHAUST UP TO ROOF; EXTEND TO ONE FOOT BEYOND ROOF LEVEL. EFFE \CE ��AWI\GS CC\STUCTI \ \TES Nly 1 COORDINATE WITH BOEING FACILITIES DEPARTMENT FOR ANY REMOVAL OR HANDLING OF ASBESTOS CONTAINING MATERIAL INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. COORDINATE DUCTWORK ROUTE WITH EXISTING CONDITION. 6"0 OVEN EXHAUST SHALL BE NO LESS THAN 6'-0" ABOVE NEW SUBSTATION. POINT OF CONNECTION TO EXISTING AIR LOUVER. TRANSITION TO COOLING EXHAUST DAMPER. COORDINATE EXACT SIZE WITH OVEN. TRANSITION TO COOLING INLET DAMPER. COORDINATE EXACT SIZE WITH OVEN FURNISHED. TRANSITION TO EXHAUST CONNECTION. COORDINATE EXACT SIZE WITH OVEN FURNISHED. SEE DRAWING 1A11 FOR WALL PENETRATIONS. RE .1EV1i;ED FOR CODE COMPLIANCE APPROVED DEC 0 2 2015 • City of Tukwila BUILDING DIVISION ISSUED FOR CONSTRUCTION JULY 8, 2015 RECEIVED CITY OF TUKWILA NOV 19 2015 PERMIT CENTER 4 2 0 2 4 -MiiLIE:1111111.7-- '1 SCALE: 1 /4"=1'-0" 3009 with Ave NE, Suite iao Bellevue WA 980o4 425.628.60o0 woodharbinger.com SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE EXISTING CONDITIONS A 9-120 STRAIN GAUGE OVEN 26032-01 WH MBL 07.08.15 .B. ti ACCEPTABI LITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DDA DATE SUBTITLE 12.02.14 CHECKED MBL 12.02.14 ENLARGED PLAN CURRENT REVISION SYMBOL DATE ENCINEER MBL 12.02.14 CCHECKED EL 12.02.14 APPROVED APPROVED TITLE 9-120 STRAIN GAUGE OVEN BUILDING 9-120 SHEET M456 JOB NO. 21067 COMP NO. CNELSON: 7/8/2015 11:20:38 AM 11r/11 1AA,1/1 Al 11 A /'•Trr r ATTI r IIIA DWG NO. A 4 /1 /1 1 1 A f /' EXTEND STACK 7' BEYOND ROOF LEVEL, PROVIDE COVERED CHIMNEY WITH CLOSURE RING 161'0 EXHAUST HOOD OWNER FURNISHED AGE OVEN DETAIL - OVE\ EXHAUST 1 SCALE: NONE CHIMNEY ROUND TOP (CT), SS NECK SIZED TO MATCH INNER DUCT DIAMETER DOUBLE WALL CLOSURE RING DETAIL - OVE\ EXHAUST OU SCALE: NONE BALL VALVE WATTS #B-6080 3/8"x 3/8"x 1/2" IPS REDUCING TEE 3/8" PARKER QUICK COUPLER, E-Z-MATE SERIES EZ-371-6MP (TYP) KINDORF C-105 PIPE CLAMP OR EQUAL 3'-6" FROM FLOOR FRONT VIEW SIDE VIEW M45X,M537 \ D TOP(/7-2 M537. .1vj537 1/2" IPS x 4" LONG NIPPLE 3/8" IPS STREET ELBOW (2 PLACES) WALL OR STRUCTURE (REF) WALL BOARD ANCHOR SCREW AND WASHER MOLLY BOLT OR EXPANDING TYPE ANCHOR (2 PLACES) B-LINE B-22 CHANNEL OR EQUAL WALL V CU \TED DUPLEX AR OUTLET SCALE: NONE ROOF ROOF PARAPET - WALL SUPPORT ASSEMBLY PER MANUFACTURER RECOMMENDATIONS (TYP) 7---BLDG WALL • xN_ M537 M537 PROVIDE ADDITIONAL SEISMIC/WIND SUPPORTS AS REQUIRED PROVIDE 1" DRAIN WITH PLUG z—NORTH FACE OF B9-120 GRADE SECTIO\ OVE\ EXHAUST SCALE: NONE REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 2 2015 • City of Tukwila BUILDING DIVISION ISSUED FOR CONSTRUCTION JULY 8, 2015 RECEIVED CITY OF TUKWILA NOV 1 9 2015 PERIVIlt CENTER der 3oo9 inth Ave NE, Suite ioo Bellevue WA 98004 425.628.6000 woodharbinger.com REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CDC RELOC—STRAIN GAUGE LAB—PKG 6A—NORTH J#19670-10 WH MBL 02.17.14 ADDENDUM 02 — PKG 6A—NORTH J#19670-10 WH MBL 05.20.14 9-120 STRAIN GAGE OVEN 26032-01 WH MBL 07.08.15 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CHECKED ENGINEER CHECKED APPROVED APPROVED DATE SUBTITLE DETAILS CURRENT REVISION SYMBOL 26032-01 3 DATE 07.08.15 TITLE 9-120 STRAIN GAUGE OVEN BUILDING 9-120 SHEET M537 JOB NO. COMP NO. 111. I I .91.. I • DWG NO. 1 IN CNELSON: 7/8/2015 ZONE 1 (E)16/26 ZONE 2 (E)16/20 ZONE 2 (E) 64x24� SYM (E)35/24 R.A. - r® -16x24 1 ED PLENUM 16x12 22x14 18x14 28x20 18x36 36x18 7 7 12x16 18x34 34x18 22x30 10"0 8"0 14 6" 0 OVEN EXHAUST x14- 8x12 18x24 L 20x16 20" 0 12x16 SQUARE THROAT, RADIUS HEEL, 28x62 18x12 12x12 SQUARE THROAT, RADIUS HEEL, 30x22 RELIEF AIR CONC PAD, SEE STRUC DWG FINISHED FLOOR SECTIO\ SCALE: 1/4"=1'-0" REVISION BY E M450 M542 APPROVED r30x50 4_ 24x86 10"0 8"0 14"0 SECTIO SCALE: 1/4"=1'-0" 50x30 96x40 oa„nn SECTIO SCALE: 1 /4"=1'-0" 12x12 PLENUM /48x40 PLENUM RELIEF AIR LOUVER 40x48 (BEHIND) RELIEF AIR LOUVER 40x96 PLENUM 64x24 DATE SYM 16x12 20x28 26x12 18x14 M45 20x28 14x22 14x18 • 542 18x34 30x22 18x36 12x12 r 20x28 18x12 14x42 F- -I� 18x36 -14x42 12x16 PLENUM 90x40-\ 18x14 __-._)\28x20 22x1 18x1 f12x12 I I/ My' T 18x341 18x34 1 18x36X 1 i I 1 14x22 20x28 1 I 1 1 - 20x28 (E)20x13 1 ,K I 14x42 (E)20x38 - L 18x36 - ' 42x14 \--..../ CNC PA, SEE STRUC DWG FINISHED FLOOR SECTIO SCALE: 1/4"=1'-0" REVISION BY APPROVED (1-7 M51 M450 42 DATE 9-120 STATION 5 AHU REPLACEMENTS 21067 WH MBL 04.07.15 A 9-120 STRAIN GAUGE OVEN 26032-01 WH MBL 07.08.15 4x42 E)20x24 E)20x14 E)20x13 �-22x 1 /42x 14 36x18 CONC PAD, SEE STRUC DWG (E)22/12 (E)17/12 36x18 64x24 FINISHED FLOOR FINISHED FLOOR 12x1 40x96 r20x16 r-18x14r22x18 j-12x8 28" DIA (E)OA LOUVER 40x96 40x48 64x24 SECTIO SCALE: 1 /4"=1'-0" 12x1 (E)OA LOUVER 40x48 36x18 64x24 12x2 PLENUM 8x30 AH if1 PLENUM CONC PAD, SEE STRUC DWG FINISHED FLOOR c M450I M542 18x14 14x32 12x18 Ill\ /I\ /1111\/ XI /\ I XIXIX 111/ \1/ \I111/\ \II V II/ SECTIO\ 12x12 18x12 CONC PAD, 17SEE STRUC DWG — FINISHED FLOOR SC LE: M450 M542 13x20 14x20 24x20 LEGE\D 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M2C, M 1 C, AND M 1 E. GE\EAL \OTES FOR AH1F1 DETAIL, SEE M542 FOR AH1G1 DETAIL, SEE M540 -FETE\CE .DAWI\S'S CO \STRUCTI 3 \ \OTES TRANSITION TO COOLING COORDINATE EXACT SIZE TRANSITION TO COOLING COORDINATE EXACT SIZE TRANSITION TO EXHAUST COORDINATE EXACT SIZE EXHAUST D WITH OVEN AMPER. FURNISHED. INLET DAMP WITH OVEN CONNECTIO WITH OVEN ER. FURNISHED. N. FURNISHED. 8" 14"0 24x 16 0 10" 0 6" 0 OVEN EXHAUST 22"0 RAILING 16x24 (E) J-BOX, REF " 30x20 18x34 42x14 ,' Alla 22„0 24x 16 \6 24x 16 I '� \ ' < \-- OVEN COOL DOWN EXHAUST !RECEIVED 81'0' 8»0 16x24 OVEN COOL DOWN OUTSIDE AIR INTAKE OVEN RENAMED FOR CODE COMPLIANCE APPROVED DEC 0 2 2015 Oity of Tuktiv1W. CITY OF TUKWILA :: NOV 19 2015 PERMIT, CENTER FINISHED FLOOR BUILDING DIVISION SECTIO\ SCALE: 1/4"=1'-0" 4 M450, M456 M542 2 0 2 8 SCALE: 1 /4"=1'-0" ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DDA CHECKED MBL ENGINEER MBL CHECKED CEL APPROVED APPROVFI) ISSUED FOR CONSTRUCTION JULY 8, 2015 DATE SUBTITLE 12.02.14 12.02.14 12.02.14 12.02.14 TITLE SECTION 9-120 STRAIN GAUGE OVEN BUILDING 9-120 3oa9 u2th Ave NE, Suite soo Bellevue WA 9Boo4 425.628.6000 woodharbinger.com CURRENT REVISION SYMBOL DATE 26032-01 A 07.08.15 SHEET JOB NO. .... DWG NO. M542 COMP NO.