Loading...
HomeMy WebLinkAboutPermit M15-0157 - UNIVERSAL BUILDING SYSTEMS - GAS/ELECTRIC ROOFTOP UNITS AND DUCTUNWERSAL BUILDING SYSTEMS 14520 INTERURBAN AVE S M15-0157 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 3365901630 14520 INTERURBAN AVE S Project Name: UNIVERSAL BUILDING SYSTEMS Permit Number: Issue Date: Permit Expires On: M 15-0157 1/29/2016 7/27/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: SANFT LOUIE 6120 52ND AVE S , SEATTLE, WA, 98118 BILL ALSEPT 3903 SMITH AVE , EVERETT, WA, 98201 WILLIAMS MECHANICAL INC 3903 SMITH AVE , EVERETT, WA, 98201 License No: WILLIM1088PA Lender: Name: Address: Phone: (425) 754-8759 Phone: (425) 303-0828 Expiration Date: 10/1/2017 DESCRIPTION OF WORK: INSTALL 2 GAS/E;ECTRIC ROOF TOP UNITS WITH NEW DUCT SYSTEMS Valuation of Work: $14,000.00 Type of Work: NEW Fuel type: GAS Fees Collected: $376.54 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2014 2014 2014 2012 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: / Date: // / /e( Print Name: /a/9/7,7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 2: ***MECHANICAL PERMIT CONDITIONS*** 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 7: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 8: Readily accessible access to roof mounted equipment is required. 9: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Iv l 6.011 Project No. In Date Application Accepted: f l/ 1 I I d Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: 1440 1450 Interurban ave. S Building D Universal Building Systems King Co Assessor's Tax No.: 3365901650 Suite Number: 1 Floor: PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: bill alsept Address: 3903 smith ave City: everett State: wa Zip: 98201 Phone: (425) 754-8759 Fax: Email: bill@williams-mechanical.com New Tenant: m Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: williams mech inc Address: 3903 smith ave City: everett State: wa Zip: 98201 Phone: (425) 754-8759 Fax: Contr Reg No.: WILLIMO88PA Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 14,000 Describe the scope of work in detail: Install two gas/electric roof top units with new duct systems. Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric ❑ Gas Other: H:lApplicalions\Fomis-Applications On Line120I I ApplicationslMechanical Permit Application Revised 8-9-I I.docc Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm 2 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser 28 Thermostat 2 Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor QtY 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Od a `��G Signature: Date: 12/01/2015 Print Name: Bill Alsept Day Telephone: Mailing Address: 3903 smith ave everett wa 98201 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number R6758 DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK $585.10 EL15-1050 Address: 14520 INTERURBAN AVE S Apn: 3365901630 $81.80 ELECTRICAL $77.90 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 I $77.90 TECHNOLOGY FEE $3.90 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.90 M15-0157 Address: 14520 INTERURBAN AVE S Apn: 3365901630 $376.54 MECHANICAL $362.06 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $257.15 PLAN CHECK FEE R000.322.102.00.00 0.00 $72.41 TECHNOLOGY FEE $14.48 TECHNOLOGY FEE R000.322.900.04.00 0.00 $14.48 PG15-0139 Address: 14520 INTERURBAN AVE S Apn: 3365901630 $126.76 GAS $121.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.38 TECHNOLOGY FEE $4.88 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R6758 $4.88 $585.10 Date Paid: Tuesday, December 01, 2015 Paid By: WILLIAM H ALSEPT Pay Method: CREDIT CARD 044062 Printed: Tuesday, December 01, 2015 2:41 PM 1 of 1 C1t, L/�SYSTEMS Ice INSPECTION RECORD Retain a copy with permit �3 -. (r7 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 \1( 4(k) Type �Inspectio�: Date Called: e-f-' Ad r ss: '-(/ i V.r?0 --f/C c(� Special Instructions: Date Wanted: a.m. J (Z" p.m. Requester: Phone No: 1Approved per applicable codes. Corrections required prior to approval. C MMENTS: 1_J Inspector: Date:5_r�_r� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO, INSPECTION RECORD Retain a copy with permit .A T- 007 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 �Gu+o fl(d5 sylf Type o4s2t- nProject:. Fl&tCt f Address. i J t 4Je Date Called: So , 114 Special Instructions: tiAt Date 11��VVanted: a.m. Reque�te ��It 45.671/4 Phone No: T —7s Lt— 717 ElApproved per applicable codes. I Corrections required prior to approval. COMMENTS: 'firov;k *-1-(veriIan ,5f ®r tori*L re.rfr\-5P0'r ova Inspector: Date: tio,_6- t.6 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD I Retain a copy with pelt I 0--°l 7 INSPECTION NO. PERMIT NO. CITY OF TUKWILA, BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pr''v;. / s.,yst Type/Jo�f�I,n`sp[ectio ii,`c / drress: �-/ 7-0 At'iY- ,✓ i _ / �� Da e Called: Special Instructions: Date Wanted: 3 (✓t% 6' a.m. p.m. R u ter: 6(( t IJ (® e'I i t Phon No: —75-cf ` 7 S-q Approved per applicable codes. IY1 Corrections required prior to approval. COMMENTS:E[.frig i h Q--, przsv (de -1-A-1; v-e 6 tr-f, rf ' r dii't o e p---i-r-tarc (9m0E--7t--.z79 fkogl-c, Cszf( ftv r;k5-' r dfri Inspector: Date f� —46 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION /vll5 d/C' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project:, /Q y.�y� �0rt� �+/ ✓ p ��i y of Inspection: c7E, /gel) Address: r� D t Cal Special Instructions: �j �''" b(/� �eE pGCc , �1 ,42/ii _ Date anted: a.m //.m. Requester Phone No: Er-7 73"f U ,'5e7 t t Approved per applicable codes. Corrections required prior to approval. COMMENTS: CIA > Inspector: . Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. IYORK SUBMITTAL DATA RTU-2 For: Quotation Order #: Date: 11/25/2015 Project: TUKWILLA D BUILDING Project #: RWS11252015-03 Location: WASHINGTON Purchaser: WILLIAMS MECH-BILL Submitter: YORK NW RYAN L r REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 8 2016 City of Tukwila BUILDING DIVISION CORRECTION RECEIVED LTR# am OF TUKWILA ti I����DEC182015 PERMIT CENTER Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 11/25/2015 Date 11/25/2015 Project Name TUKWILLA D BUILDING Project Number RWS11252015-03 Client / Purchaser WILLIAMS MECH-BILL Submittal Summary Page YORK Qty Tag # Model # Description 1 ZE048N10A2AAA4 4 Ton, York Sunline Single Packaged R-410A Air Conditioner, 14.0 SEER / 12.0 EER, Single Stage Cooling, 100 MBH Output Aluminized Steel, Single Stage Gas Heat, 1 HP Direct Drive Blower, 1" Throwaway Filters, 208/230-3-60, Microchannel Condenser Coil, Simplicity Lite Control, Galvanized Steel Drain Pan 1 1RC0434 Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) 1 2EE04709224 Single Enthalpy Low Leak Jade Downflow or Horizontal Economizer w/o Barometric Relief 1 1 RD0410 Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted) Equipment start-up and commissioning by a factory trained technician is recommended. Contact your supplying distributor or sales representative for additional information & guidance. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 11R5/2015 �YORK� Small Sunline Single Package R-410A Air Conditioner Page: 3 Project Name: TUKWILLA D BUILDING Unit Model #: ZE048N10A2AAA4 Quantity: 1 System: ZE048N10A2AAA4 Cooling Performance Total capacity 51.3 MBH Sensible capacity 39.5 MBH Refrigerant type R-410A Seasonal Efficiency (at ARI) 14.00 SEER Efficiency (at ARI) 12.00 EER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 59.5 °F Leaving WB temp. 58.0 °F Power input (w/o blower) 3.51 kW Sound power 80 dB(A) Gas Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 100 MBH Supply air 1786.2 CFM Heating input capacity (Max) 125 MBH Leaving DB temp. 111.8 °F Air temp. rise 51.8 °F SSE 80.6 % Stages 1 Supply Air Blower Performance Supply air 1786.2 CFM Ext static pressure 0.58 IWG Addl. Unit Losses (Options/Accessories) 0.13 IWG Blower speed 1047 RPM Duct location Bottom Motor rating 1.00 HP Actual required BHP 0.82 HP Power input 0.76 kW Elevation 0 ft. Drive type DIRECT Speed tap 5 Electrical Data Power supply 230-3-60 Unit min circuit ampacity 27 Amps Unit max over -current protection 35 Amps Dimensions & Weight Hgt 33 in. Len 83 in. Wth 45 in. Weight with factory installed options 616 lbs. Clearances Right 24 in. Front 32 in. Back 36 in. Top 72 in. Bottom 0 in. Left 36 in. Note: Please refer to the tech guide for listed maximum static pressures 4 Ton • York Units are Manufactured at an ISO 9001 Registered Facility and Each Rooftop is Completely Computer -Run Tested Prior to Shipment. Unit Features • Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Salt Spray Test (ASTM B-117 Standards) • Through -the -Curb and Through -The -Base Utility Connections • Either Supply and/or Retum can be Field Converted from Vertical to Horizontal Configuration without Cutting Panels. • Full Perimeter Base Rails with Built in Rigging Capabilities • Galvanized Steel Drain Pan • Single Stage Cooling • Solid Core Liquid Line Filter Driers • Microchannel Condenser Coil • 100 MBH Output Aluminized Steel, Single Stage Gas Nominal Heat • 1 HP Direct Drive Blower • Unit Ships with 1" Throwaway Filters with a Standard Filter Rack That Will Accept up to 2" Filters • Single Point Power Connection • Short Circuit Current 5kA RMS Symmetrical Standard Unit Controller: Simplicity Control Board • An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag, Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic and Fault Code Display. Allows all units to operate in the cooling mode down to 0 °F outdoor ambient without additional components or intervention. • Safety Monitoring - Monitors the High and Low -Pressure Switches, the Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition Failures, Safety Lockouts and Repeated Limit Switch Trips. Warranty • One (1) Year Limited Warranty on the Complete Unit • Five (5) Year Warranty - Compressors and Electric Heater Elements • Ten (10) Year Warranty - Aluminized Steel Tubular Heat Exchangers Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 11/25/2015 P • ,ea•YORK Small Sunline Single Package R-410A Air Conditioner Page: 4 Project Name: TUKWILLA D BUILDING Unit Model #: ZE048N10A2AAA4 Quantity: 1 System: ZE048N10A2AAA4 Factory Installed Options ZE048N10A2AAA4 Product Category: Product Identifier: Nominal Cooling Capacity: Heat Type and Nominal Heat Capacity: Airflow: Voltage: Installation Options: Additional Options: Product Generation: 1 RC0434 - Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) (86.0 Ibs) 2EE04709224 - Single Enthalpy Low Leak Jade Downflow or Horizontal Economizer w/o Barometric Relief (50.0 Ibs) 1 RD0410 - Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted) (6.0 Ibs) z E 048 N10 A 2 A AA 4 York Sunline Single Packaged R-410A Air Conditioner 14.0 SEER / 12.0 EER 4 Ton Single Stage Cooling 100 MBH Output Aluminized Steel, Single Stage Gas Heat 1 HP Direct Drive Blower 1" Throwaway Filters 208/230-3-60 Microchannel Condenser Coil Simplicity Lite Control Galvanized Steel Drain Pan Field Installed Accessories Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 11/25/2015 0 47. 42) U = a a '^ o r as /EA a3 a a) Tric tn cc Project Name: TUKWILLA D BUILDING ZE048N10A2AAA4 E N Consolidated Drawing LOADS (LBS) (BASE UNIT) 4 POINT CORNER r-. m 'm M o rn vlm ` r; O, I 0, �..1 K1 I r-1 a-1 r-1 N N ZIm en oN u1 m co co WiVoN on 011 LLI 0 0 N�N m 0 rn co !•:4-. ear, Ii, CO un N 00 NcD CO 40 CO CA m m On 1- m 0I N m r-1 aco co no N CO 101 10 0 on V 1 m 0 o. ON On 2 N 1 on r-1 N KI 1-10 0 ce.. 0.. 0 0_. of 0 m Nom 4--1 r-1 r-" a-1 r-1 X I X CO 0 on CO CO00 m m ol 4-1 4-1 0 CO CO 10 0 0 u" 1-1 co on m 00 ON 1.0 X X m 0 1.0 m 0 u, '0 i J. an s .0 No 0 - CO r--1 ry mw _L m Q'/ N >- CO r+ u 0 m O m n� 0ON m z 1-1 CC 1-4 3 CO 0 0 OH 0 0 CC NU a m _ v Q 3 r X 02W>-T . ft 1-00 0_ Q V-I CO to 0 00 S cc 2 1- Q d 0 CO .--1 1--12 Oa 4CE0 0N0 0 r �-' Ce 2aorn r'— CO �w4 wp wO w'0 ON Z_ NNI- NN - p000. O1-" ZZ0 EFw u 0200CC Q 00W >- 0iuiui 0w 00N ZV 0 r. 2 ZJ --120H0Z\z¢^ OZ Or 1-10 mLL0-112v,2 . 03 p00r w0m>2Q Q>Z - • 2 2 V\000O 21--1w1--I= QF1- 00 Z3 co Q1-ZZ H ww2 V1 00 J O co O� 0 42 0i N 40 N Q t7 0 Z C Z Q ^u 2 10 0 r--1 Co en .CO 10-u.0Iti 1- 0 Q r 0 w p 2 O NO O, uum`On .-I mu V1�Qp Oiy>, 0_' Ore - >.d0 IS-Io WZQH 22 GI 4,2 oQW42aZ CNNZ OWR - cr 000Q �ty Hp ZV NNmN m r-Im I� Q0 JO ZOZw 2 OQw -- ¢ m 0 O 2 w.ViH ZZ1Zi O v31Lu OSCOw w=O0 V 1-, 0I-001-_I O Vlw I--Ip } mZQ1-0 VV12 02 CI0H •• 0MCC 2 CC 0000 O-lw1--1 r ut� -• 0Qr 000m0 Z31-1Q 2\ 0 IVI- -- OuV-r V w O00Otn0 Z1_ 0 02 21- Z -• rvt Qw In 0Z0200w 1-4• i 21-1-Iw 0 w 0Oz23Om001--Zw Z1-04_ O3Z m J LL r CO OO 000r�-I ce V v)m10H F. OOCI0 W 0 r-INCr; u, IO 0 XP (HEAT PUMP) UNITS 10 z x 0- UJ DIRECTION OF AIRFLOW CENTER OF GRAVITY rel u 4.11 CO N m Cn 44-1 0 2LU COMBUSTION AIR 1 3, O, N m ry 1 ` 0 m rm m -0- CONTROL WIRING 03 N CO N 9u A-7 CO ON co 0 m cs 1 2 Fi inted 11/25/2015 Information is subject to change without notice. Check local codes. Unitary Sales Tool v1.5.9.0 YORK Small Sunline Single Package R-410A Air Conditioner Page: 6 Project Name: TUKWILLA D BUILDING Unit Model #: ZE048N10A2AAA4 Quantity: 1 System: ZE048N10A2AAA4 h. I if - 4 Typical Application ROOF JACK 77 INSTALLATION U ___ I ROOF CURB INSTALLATION I 1 I I I I FIELD -SUPPLIED DISCONNECT SWITCH TO POWER SUPPLY 1 CONDENSATE TRAP ,11\ II I I. SLAB ON GROUND INSTALLATION JL 1 SUPPLY AIR CONTROL WIRING DUCT TO INDOOR RETURN AIR THERMOSTAT DUCT ROOF CURB I, a MANUAL GAS SHUT-OFF VALVE TO GAS SUPPLY LINE Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 11/25/2015 WORK Small Sunline Single Package R-410A Air Conditioner Page: 7 Project Name: TUKWILLA D BUILDING Unit Model #: ZE048N10A2AAA4 Quantity: 1 System: ZE048N10A2AAA4 CONTACTOR @CI) _ � I � I GROUND LUG L Typical Field Power and Control Wiring TYPICAL POWER WIRING FIELD -SUPPLIED DISCONNECT r-SINGLE - r -> PHASE _ --O- 0- -1-> POWER - ; I SUPPLY -� REFER TO THE ELECTRICAL DATA GROUND L TABLES TO SIZE THE DISCONNECT LUG SWITCH, OVER CURRENT PROTECTION AND WIRING. CONTACTOR 0 0 0 •s I I L L FIELD -SUPPLIED DISCONNECT r r__ -7 �} -r THREE -0-- }f} - F } PHASE -a-" 0--L > POWER L SUPPLY TYPICAL COOL/HEAT CONTROL WIRING COOLING ONLY (24 VOLT THERMOSTAT) COOLING / HEATING (24 VOLT THERMOSTAT) THERMOSTAT` UNIT TERMINAL TERMINALS STRIP TB1 24 VOLT TRANSFORMER 124 VOLT THERMOSTAT. TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING. USE A 2 STAGE COOLING THERMOSTAT COOLING / HEATING (ELECTRONIC THERMOSTAT) MULTI STAGE THERMOSTAT1 TERMINALS ADD JUMPER 4 ADD / JUMPER UNIT TERMINAL STRIP TB1 -- 2 - NOT USED TO REMOTE SENSOR IF USED 24 VOLT TRANSFORMER ELECTRON C PROGRAM .CABLE THERMOSTAT TYP CAL SECOND STAGE. COOL'NG S NOT REOURED ON UMTS LESS ECONOMIZER ' SECOND STAGE HEAT PIG S ONLY REOU RED ON UN TS W TH A TWO STAGE ELECTR C: HEATER OR 2 STAGE GAS HEAT. REMOVE JUMPER J2 FROM TERMINALS 4 AND 9 ON JUMPER PLUG CONNECTOR PG ON UNITS WITH ECONOMIZER. TERMINALS Al AND A2 PROVIDE ARELAY OUT -PUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE THERMOSTAT SWITCHES TO THE SET -BACK POSITION. THERMOSTAT' TERMINALS UNIT TERMINAL STRIP TB1 24 VOLT TRANSFORMER '24 VOLT THERMOSTAT. TO CONTROL THE ECONOMIZER ON THE SECOND STAGE COOLING OR TO HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT. USE A 2 STAGE COOL AND HEAT THERMOSTAT. COOLING / HEATING (ELECTRONIC THERMOSTAT) SINGLE STAGE THERMOSTAT' TERMINALS ADD - JUMPER UNIT TERMINAL STRIP TB1 24 VOLT TRANSFORMER 'ELECTRONIC PROGRAMMABLE THERMOSTAT TYPICAL TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING. USE A 2 STAGE COOL AND HEAT THERMOSTAT Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 11/25/2015 YORK` Small Sunline Single Package R-410A Air Conditioner Page: 8 Project Name: TUKWILLA D BUILDING Unit Model #: ZE048N10A2AAA4 Quantity: 1 System: ZE048N10A2AAA4 )00771 BACK OF UNIT SUPPLY` AIR RETURN" AIR 19-1 /2' 37-1 /4" DUCT SIZES: Supply Air = 19" x 19" Return Air = 19" x 19" 1RC0434 Roof Curb 2" TYP. DUCT SUPPORT RAILS iRC0434 Roof Curb Dimensions 2_ 73" COMPRESSOR AND CONDENSER END OF UNIT FRONT OF UNIT 14" 'Supply and Return Air (including duct support rails) shown are typical for bottom duct applications. For location of horizontal duct applications (on back of unit), refer to Unit Dimensions details. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 11/25/2015 Date 11/25/2015 Project Name TUKWILLA D BUILDING Project Number RWS11252015-03 Client / Purchaser WILLIAMS MECH-BILL Guide Specification Summary Page YORK` Product Series Models and Unit Tags `Small Sunline ZE048N10A2AAA4 Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 11/25/2015 121YORK Guide Specification for York Sunline Page: 10 GENERAL Units shall be manufactured by Johnson Controls Unitary Products in an ISO 9001 certified facility. York Sunline units are convertible single package units. Although the units are primarily designed for curb mounting on a roof, they can also be slab -mounted at ground level or set on steel beams above a finished roof. Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory -mounted options and field -installed accessories to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power exhaust are suitable for bottom duct connections only. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. All non -Scroll compressors include crankcase heaters and all compressors have internal pressure relief. Every refrigerant circuit includes a liquid line filter -drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch. The unit control circuit includes a 75 VA transformer, a 24-volt circuit breaker and a relay board with a compressor lockout circuit, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All models are CSA listed. All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements carry a 5- year warranty. Aluminized steel and Stainless steel tubular heat exchangers carry a 10-year warranty. DESCRIPTION Units shall be factory -assembled, single packaged, Electric Cooling/Gas Heat, Electric Cooling/Optional Electric Heat, Heat Pump/Optional Electric Heat are designed for outdoor mounted installation. The 3 ton, 4 ton and 5 ton units shall have minimum SEER rating of 13.0 with heat pumps having a 7.7 H.S.P.F. The 6 Ton Cooling only or Cooling with Electric Heat shall have 11.2 EER, 6 Ton Cooling with Gas Heat shall have 11.0 EER. They shall have built-in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R-410A refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units the cooling performance shall be rated in accordance with DOE and AHRI test procedures. Units shall be CSA listed, classified to ANSI Z21.47, UL 1995/CSA No. 236 standards. UNIT CABINET Unit cabinet shall be constructed of galvanized steel, with exterior surfaces coated with a non -chalking, powdered paint finish, certified at 1000 hours salt spray test per ASTMB117 standards. Indoor blower section shall be insulated with a minimum 1/2" thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be "large" size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 1" filters shall be furnished and be accessible through a removable access door, sealed airtight. Units filter track shall be designed to accommodate either 1" or 2" filters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air by-pass of the coils. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self -draining standards. Condensate connection shall be a minimum of 3/4" I.D. female and be a ridged mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY The indoor fan shall be a factory installed direct -drive or belt -drive assembly that includes an adjustable pitch motor pulley. Job site selected (B.H.P.) brake horsepower shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double -inlet type with forward -curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fan shall be of the direct -driven propeller type, discharge air vertically, have aluminum blades riveted to a corrosion resistant steel spider bracket and shall be dynamically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings, internally protected against overload conditions and staged independently. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 11/25/2015 YORK Guide Specification for York Sunline Page: 11 REFRIGERANT COMPONENTS Compressors: a. Shall be internally protected with internal high- pressure relief and over temperature protection. b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Evaporator coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator coils shall be of the direct expansion, draw-thru design. c. Condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed or Micro -Channel aluminum tube, aluminum fins. d. Condenser coils shall be of the direct expansion, draw thru design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent fixed -orifice or thermally operated expansion devices. b. Filter drier/strainer to eliminate any moisture or foreign matter. c. Accessible service gage connections on both suction and liquid lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. d. The refrigeration system shall provide at least 15°F of sub -cooling at design conditions. Unit Controls: a. Unit shall be complete with self-contained low -voltage control circuit protected by a resettable circuit breaker on the 24-volt transformer side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor. c. Loss-of-charge/Low-pressure switch. d. High-pressure switch. e. Freeze -protection thermostat, evaporator coil. f. Unit shall incorporate "AUTO RESET" compressor over temperature, over current protection. g- j• Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. h. Unit control board shall have on -board diagnostics and fault code display. i. Standard controls shall include anti -short cycle and low voltage protection, and permit cooling operation down to 0°F. Control board shall monitor each refrigerant safety switch independently. k. Control board shall retain last 5 fault codes in non volatile memory which will not be lost in the event of a power loss. GAS HEATING SECTION (SINGLE STAGE) Shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. Venter wheel shall be constructed of stainless steel for corrosion resistance. The heat exchanger shall be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 25°F. Burners shall be of the inshot type, constructed of aluminum coated steel and contain air mixture adjustments. All gas piping shall enter the unit cabinet at a single location through either the side or curb without any field modifications. Integrated control boards shall provide timed control of evaporator fan functioning and burner ignition. Heating section shall be provided with the following minimum protection. a. b. c. d. e. Primary and auxiliary high -temperature limit switches. Induced draft motor speed sensor. Flame roll out switch. Flame proving controls. If any of the above safety devices trip, a LED (light - emitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage, 40% Capacity 2nd Stage. UNIT OPERATING CHARACTERISTICS Unit shall be capable of starting and running at 125°F outdoor temperature, exceeding maximum load criteria of AHRI Standard 210/240. The compressor, with standard controls, shall be capable of operation down to 0°F outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up (Gas heat only). Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 11/25/2015 EYORK Guide Specification for York Sunline Page: 12 ELECTRICAL REQUIREMENTS All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES • Compressor 5 Years • Heat Exchanger 10 Years • Electric Heat Element 5 Years • Other Parts 1 Year ADDITIONAL FACTORY INSTALLED OPTIONS FIELD INSTALLED OPTIONS • Roof Curb — 14" high, full perimeter curb with wood nailer (shipped knocked -down). • Barometric Relief Damper — This damper accessory can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 11/25/2015 VuRK; " SUBMITTAL DATA Order #: Project: Project #: Location: Purchaser: Submitter: For: Quotation Date: 12/04/2015 UNIVERSAL BUILDING SYSTEMS RWS 12042015-04 WASHINGTON WILLIAMS MECH-BILL YORK NW-RYAN CORRECTION LTR# LS-0157 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 8 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 18 2015 PERMIT CENTER Unitary Sales Tool v1.5.9.0 information is subject to change without notice. Check local codes. Printed 12/04/2015 Date 12/04/2015 Project Name UNIVERSAL BUILDING SYSTEMS Project Number RWS12042015-04 Client / Purchaser WILLIAMS MECH-BILL WORK Submittal Summary Page Qty Tag # Model # Description 1 ZF060N10A2AAA4 5 Ton, York Sunline Single Packaged R-410A Air Conditioner, 13.0 SEER / 10.8 EER, Single Stage Cooling, 100 MBH Output Aluminized Steel, Single Stage Gas Heat, 1 HP Direct Drive Blower, 1" Throwaway Filters, 208/230-3-60, Microchannel Condenser Coil, Simplicity Lite Control, Galvanized Steel Drain Pan 1 1RC0434 Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) 1 2EE04709224 Single Enthalpy Low Leak Jade Downflow or Horizontal Economizer w/o Barometric Relief 1 1 RD0410 Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted) Equipment start-up and commissioning by a factory trained technician is recommended. Contact your supplying distributor or sales representative for additional information & guidance. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 12104/2015 TYORK Small Sunline Single Package R-410A Air Conditioner Page: 3 Project Name: UNIVERSAL BUILDING SYSTEMS Unit Model #: ZFO60N10A2AAA4 Quantity: 1 System: ZF060N10A2AAA4 Cooling Performance Total capacity 59.8 MBH Sensible capacity 45.3 MBH Refrigerant type R-410A Seasonal Efficiency (at ARI) 13.00 SEER Efficiency (at ARI) 10.80 EER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 'F Leaving DB temp. 59.0 °F Leaving WB temp. 57.6 °F Power input (w/o blower) 4.54 kW Sound power 82 dB(A) Gas Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 100 MBH Supply air 2000 CFM Heating input capacity (Max) 125 MBH Leaving DB temp. 106.3 °F Air temp. rise 46.3 °F SSE 80.6 % Stages 1 Supply Air Blower Performance Supply air 2000 CFM Ext. static pressure 0.6 IWG Addl. Unit Losses (Options/Accessories) 0.15 IWG Blower speed 1103 RPM Duct location Bottom Motor rating 1.00 HP Actual required BHP 1.02 HP Power input 0.95 kW Elevation 0 fL Drive type DIRECT Speed tap 5 Electrical Data Power supply 230-3-60 Unit min circuit ampacity 27.5 Amps Unit max over -current protection 35 Amps Dimensions & Weight Hgt 33 in. Len 83 in. Wth 45 in. Weight with factory installed options 644 lbs. Clearances Right 24 in. Front 32 in. Back 36 in. Top 72 in. Bottom 0 in. Left 36 in. Note: Please refer to the tech guide for fisted maximum static pressures 5 Ton • York Units are Manufactured at an ISO 9001 Registered Facility and Each Rooftop is Completely Computer -Run Tested Prior to Shipment. Unit Features • Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Salt Spray Test (ASTM B-117 Standards) • Through -the -Curb and Through -The -Base Utility Connections • Either Supply and/or Return can be Field Converted from Vertical to Horizontal Configuration without Cutting Panels. • Full Perimeter Base Rails with Built in Rigging Capabilities • Galvanized Steel Drain Pan • Single Stage Cooling • Solid Core Liquid Line Filter Driers • Microchannel Condenser Coil • 100 MBH Output Aluminized Steel, Single Stage Gas Nominal Heat • 1 HP Direct Drive Blower • Unit Ships with 1" Throwaway Filters with a Standard Filter Rack That Will Accept up to 2" Filters • Replacement Filters: 2 - (15" x 20" x 1" or 2") and 1 - (14" x 25" x 1" or 2"). Unit accepts 1" or 2" wide filters. • Single Point Power Connection • Short Circuit Current: 5kA RMS Symmetrical Standard Unit Controller: Simplicity Control Board • An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag, Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic and Fault Code Display. Allows all units to operate in the cooling mode down to 0 °F outdoor ambient without additional components or intervention. • Safety Monitoring - Monitors the High and Low -Pressure Switches, the Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition Failures, Safety Lockouts and Repeated Limit Switch Trips. Warranty • One (1) Year Limited Warranty on the Complete Unit • Five (5) Year Warranty - Compressors and Electric Heater Elements • Ten (10) Year Warranty - Aluminized Steel Tubular Heat Exchangers Unitary sales Toot v1.5.9.0 tntormation is subject to change without notice. Check local codes. Printed 12:04/2015 L1YORK Small Sunline Single Package R-410A Air Conditioner Page: 4 Project Name: UNIVERSAL BUILDING SYSTEMS Unit Model #: ZFO60N10A2AAA4 Quantity: 1 System: ZFO6ON10A2AAA4 Factory Installed Options ZFO6ON 10A2AAA4 Product Category: Product Identifier: Nominal Cooling Capacity: Heat Type and Nominal Heat Capacity: Airflow: Voltage: Installation Options: Additional Options: Product Generation: 1RC0434 - Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) (86.0 Ibs) 2EE04709224 - Single Enthalpy Low Leak Jade Downflow or Horizontal Economizer w/o Barometric Relief (50.0 Ibs) 1 RD0410 - Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted) (6.0 Ibs) Z F 060 N10 A 2 A AA 4 York Sunline Single Packaged R-410A Air Conditioner 13.0 SEER / 10.8 EER 5 Ton Single Stage Cooling 100 MBH Output Aluminized Steel, Single Stage Gas Heat 1 HP Direct Drive Blower 1" Throwaway Filters 208/230-3-60 Microchannel Condenser Coil Simplicity Lite Control Galvanized Steel Drain Pan Field Installed Accessories Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015 0 0 0 z H N 0. A -• NN upmp 0 O H Z O Om 0n CI A 01 HrT, A 2 9.0 m HO O y r -I H CO 3 -I-1 01 N C 0 Al NZ. 2� Z- H -I vS �• 1Dm 0..1 W m • 000-WIn 13 4--4 a pp nT �� ' X CH -pH 2H0H A(n0000W-1 .n-3, m t70 A0 t2 H0 >Z0 ,f O m a Hm -In NAm 2-I -1A ZJA CNh -- -0- .22 In O 30n r n 303 210. Z3 C W0O 02-.23 HN H y X 2n 2 tnn 0 n. D 33-Cr•• "' z r --in1-ion am o0m 2> A tp H 0 CD-Im m Z00 CA V1 0-1H2O A. VI Cl ZnA o xa rzazD.. «m nz arx 2,,vzmaNNaasci+ `g o-t;ti-, D cn O c,N - azm ta, m n➢m 0,0 tin . vv< 02➢ H2N 2Hmr c--e-.0 A0mHO vD-c+ln Hn mH ti-i- D 2H A 2H 0 G1 D mJCo 20 to 2m m-I-c Z1D m 2 CI -I-ID 2H0H2 2<D DA<m vm-Iv vv co - 2`" 20n2 a "' c110 H-I CD 2, a 2, o H2 n mvA0 V, 2, mr HE r01nZm 0 rn 3- mvcnn ZO 220rm AHm➢ E D-n-13WNC -I:n to O-Itn n-Ir Z to OmHD 32 V1 2ln 2 I@-, y m 2 NVN0D ZDmw 0rnrnm000 N Om3 -I VIN OA-1-.m0 OnnD Glnn 0 tD ti0-y N-m<mrn O DI.20 H22.H-.m 2Z Z ✓ rzm = u to nZr NOp r00 -< mOA D ACln 2Gt m33 m33 ^' -I2 V1 - 20MMHm n ID .I. nHH 0 -"m� NO r 0-1 WOr CO rn CD Omrn r- Ornm amm H i `0DO ➢mA co m 2 A° qAA AA N ,��, ZA n-. to a Da 3 n..-�. Ut 001 • n{< 0 G4m 2A A -1 -Ito H v X v tan m 0 S O 1.0 < 1 J. 0 01 H m NJ tr, A r rA I. m0 rtnA m ZH A A 2 -I 20 H y y 0 o0 D c.n • rn 0O n0A CD 03 A AV m m 0 m 2 (O A A N IC, A 1D VD CO m 0< A• A CO m D+ A tT Cr, NIV NOI.S09WOD 3' M x 10m m 1 w w A O m - ~ N Lr m a N mW • M O i. AlIAV 0.1 nAi 1^w W m u A INJ NJ N N H N H 01 tro N Cr, m MO1321IV D 1n A X X X' a a az • m1,1 ON co trn u~ 7 � m CO m W N r - W trn A w to A or W m A or, In A or I Z I LD-t; f LN -- CO 2.2 NJ A 101 IN A --n T+ T N rn H 2 C + : m4-=� m 01 01 110 m 1 a' m I p a m 1a A.I I n 0a Cr,'-‘ � m Ma m 1fJ t t� W N m m MGt J1N 01 Cn N ( Tv -A NJ .v N In ,CZ-, Oy 1O,V.m m Co 1-, or �m Gl • Oo �00, A A A N m 'm m CO N N A . Vw w N N^( N'N W A yWi IVVIV mu m. NJ NJ H F-. i N • H ,� N I u m'� V m m V. A 1--, V V 1D W V vv, Cr, W v co m ?� � ._, V A m W t� A b I t0 u .� m Or w1A u HI. .H H CD 0 m '0 v ^^ C .m v N - .00 O 1n CD m A V A j N N CD V VI . W m w j 'a .� co d 10 0p � 1 • N N N Co 01 '10 IW V O,. mm V• 'm; N V m. 'A A,m ✓ V •--, Oa C 1 r. 1D m w l 10 V W m Cr,W A C A: m m , m w ✓ , H n OI 4 POINT CORNER LOADS (LBS) (BASE UNIT) Sul/twig pamepliosuo3 1VVVZV04N090dZ (D z D7 a m C Z m cn cn r Q C z 0 cn Cl) cn CT raYORK Small Sunline Single Package R-410A Air Conditioner Page: 6 Project Name: UNIVERSAL BUILDING SYSTEMS Unit Model #: ZFO6ON10A2AAA4 Quantity: 1 System: ZFO6ON10A2AAA4 I 1. 4 Typical Application ROOF JACK INSTALLATION . III......_ 64-14- ....,. -- .......4.- -.1... .......: ......... mm1. ROOF CURB INSTALLATION 1 1 I FIELD -SUPPLIED DISCONNECT SWITCH TO POWER SUPPLY CONDENSATE TRAP CONTROL WIRING TO INDOOR THERMOSTAT SLAB ON GROUND INSTALLATION RETURN AIR DUCT SUPPLY AIR DUCT 1I - ROOF CURB 0 4:i MANUAL GAS SHUT-OFF VALVE TO GAS SUPPLY LINE Unitary Sales Tcol v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 12/0412015 YORKW Small Sunline Single Package R-410A Air Conditioner Page: 7 Project Name: UNIVERSAL BUILDING SYSTEMS Unit Model #: ZFO6ON10A2AAA4 Quantity: 1 System: ZFO6ON10A2AAA4 CONTACTOR - ' e . L GROUND LUG L Typical Field Power and Control Wiring TYPICAL POWER WIRING FIELD -SUPPLIED DISCONNECT SINGLE i} -0- -1- PHASE C}s t --I--> POWER SUPPLY REFER TO THE ELECTRICAL DATA TABLES TO SIZE THE DISCONNECT SWITCH, OVER CURRENT PROTECTION AND WIRING. CONTACTOR - / GROUND L LUG FIELD -SUPPLIED DISCONNECT - i 1 _> THREE -t- "4}'F S} - r -> PHASE C) " 0--" } POWER SUPPLY TYPICAL COOL/HEAT CONTROL WIRING COOLING ONLY (24 VOLT THERMOSTAT) COOLING i HEATING (24 VOLT THERMOSTAT) THERMOSTAT' UNIT TERMINAL TERMINALS STRIP TB1 24 VOLT TRANSFORMER '24 VOLT THERMOSTAT TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING, USE A 2 STAGE COOLING THERMOSTAT COOLING / HEATING (ELECTRONIC THERMOSTAT) MULTI STAGE THERMOSTAT' TERMINALS UNIT TERMINAL STRIP TB1 TO REMOTE SENSOR IF USED 24 VOLT TRANSFORMER ELECTRONIC PROGRAAIMAELE THERMOSTAT TTP'CAL ' SECOND STAGE COOL NG .SNOT REOU RED ON UN TS LESS ECONOM ZER SECOND STAGE IEAT.NG S. CIA, t REOU.RED ON UN TS W'TH A TWO STAGE Et ECTR C HEATER OR 2 STAGE GAS HEAT REMOVE JUMPER J2 FROM TERMINALS 4 AND 9 ON JUMPER PLUG CONNECTOR PS ON UNITS WITH ECONOMIZER TERMINALS AI AND A2 PROVIDE A RELAY CUT-°I.JT TO CLOSE THE OUTDOOR ECCNCMIZER CAMPERS WHEN THE THERMOSTAT SWITCHES TO THE SETBACK POSITION THERMOSTAT? TERMINALS ADD JUMPER RC1 0" I�l 'DJ UNIT TERMINAL STRIP TB1 24 VOLT TRANSFORMER '24 VOLT THERMOSTAT TO CONTROL THE ECONOMIZER ON THE SECOND STAGE COOLING OR TO HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT. USE A 2 STAGE COOL AND HEAT THERMOSTAT COOLING / HEATING (ELECTRONIC THERMOSTAT) SINGLE STAGE THERMOSTAT' TERMINALS UNIT TERMINAL STRIP TB1 24 VOLT TRANSFORMER 'ELECTRONIC PROGRAMMAR E THERMOSTAT TYPICAL TO CONTROI. THE ECONO'.7IZEP. ON SECOND STAGE COCL:HG 115E A 2 STAGE COOt AND HEAT THERMOSTAT Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Pnnted 12/0412015 ILIYORK Small Sunline Single Package R-410A Air Conditioner Page: 8 Project Name: UNIVERSAL BUILDING SYSTEMS Unit Model #: ZFO6ON1OA2AAA4 Quantity: 1 System: ZFO6ON10A2AAA4 I(wil DCL Seismic Certification SPECIAL SEISMIC CERTIFICATION OF NON-STRUCTURAL COMPONENTS AND SYSTEMS CERTIFICATE OF COMPLIANCE Johnson 04 ,1 Controls Dynamic Certification Laboratories has qualified the listed packaged rooftop units as CERTIFIED for seismic applications in accordance with the following codes and standards: CBC 2010, IBC 2009, ICC-ES AC-156 2010, ASCE 7-05 The following model designations are included in this certification. A complete list of certified models, options, and installation methods are detailed in report number 90300-1108a by Dynamic Certification Laboratories, provided by the equipment manufacturer upon request. Unitary Product Group Packaged Rooftop Units (UPG) Seismic Qualification Testing was conducted in accordance with and in strict adherence to the standards set forth within the American Society of Civil Engineers {ASCE 7) by the independent approval agency, Dynamic Certification Laboratories. The above referenced equipment is APPROVED for seismic applications when properly installed and used as intended. The basis of this certification is through testing of the active and energized components per AC156. This certification covers multiple UPG brands, including York, Johnson Controls, Coleman, Luxaire, Evcon and Fraser - Johnston. The seismic values are obtained from the Maximum Considered Earthquake Short Period Spectral Response Acceleration, Sds, as determined by the ASCE 7 seismic maps. Various installation locations/isolation configurations are covered under this certification, limited by the Sds value stated in the following table. A seismic importance factor, ip, of 1.5 applies to this certification to include essential facility requirements and life safety applications for post event functionality. The units are approved for both a rigid and flexible mount configuration. Maximum Design Sds Values of UPG Packaged Rooftop Units Series Model Tons Sds (g' Fp/Wp XP/XA/J0`XP/T0* 036, 048, 060 2F/ZS/10*ZF/JA*ZF/T0* ZR/ZK/J0"ZR/T0" H 036, 048, 060, 072 036, 048, 060 3, 4, 5 { 2.5 1: 1.88 3, 4, 5, 6 2.5 1.88 3, 4, 5 } 2.5 1.88 Page 1 of 2 Dynamic Cerrihrannn Labor -atones 1315 Greg Street. Suite 109. Sparks, NV R9431 --ph: 775-358-50R5 wwwshaketest cam Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015 YORK Project Name: UNIVERSAL BUILDING SYSTEMS Small Sunline Single Package R-410A Air Conditioner Page: 9 Unit Model #: ZFO6ON10A2AAA4 Quantity: 1 System: ZF060N10A2AAA4 li O'll DCL Seismic Certification SPECIAL SEISMIC CERTIFICATION OF NON-STRUCTURAL COMPONENTS AND SYSTEMS CERTIFICATE OF COMPLIANCE Johnson Ott Controls Table of Seismic Des gn Parameters Site Class Fa IP a, Rp z/h D 1.0 1.5 2.5 I 6.0 1.0 Site and Project Requirements It is the responsibility of the Design Professional of Record to: • Provide engineering for the anchorage and restraint of the unit • Validate Cerftficaftcn Design Parameters with actual site condiftons • Provide engineering of all equipment support structures • Confirm component configurafton Cerftficafton Issued by: Dynamic Cei rt cafton Laboratories Document Control Number: 90300-1108a-1 Issue Date: 12/19/11 Dr. Ahmad Itani, SE Dynamic Cerftficafton Laboratories -6:// Randy Forristall YORK Unitary Engineering Johnson Controls, Incorporated Page 2 of 2 Dynamic Certification Laboratories 1315 Greg Street, Suite 109, Sparks, NV 89,131 —ph 775-35S-5085 www.shaketest.com Unitary Sales Tool v1.5.9.0 Information is subject to change haul notice. Check local codes. Printed 12104/2015 YORK Small Sunline Single Package R-410A Air Conditioner Page: 10 Project Name: UNIVERSAL BUILDING SYSTEMS Unit Model #: ZFO6ON10A2AAA4 Quantity: 1 System: ZFO6ON10A2AAA4 BACK OF UNIT SUPPLY" AIR RETURN" AIR DUCT SIZES: Supply Air = 19" x 19" Return Air = 19" x 19" 1 RC0434 Roof Curb 2" TYP. DUCT SUPPORT RAILS IRC1,+.33 Roof CO) Dimensions 73 OF UNIT COMPRESSOR AND CONDENSER END OF UNIT FRONT ° Supply and Return Air (including duct support rails) shown are typical for bottom duct applications. For location of horizontal duct applications (on back of unit), refer to Unit Dimensions details. Unitary Sales Tool v1.5 0.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015 Date 12/04/2015 Project Name UNIVERSAL BUILDING SYSTEMS Project Number RWS12042015-04 Client / Purchaser WILLIAMS MECH-BILL LIYORKr. Guide Specification Summary Page Product Series Models and Unit Tags Small Sunline ZFO6ON10A2AAA4 Unitary Sales Toot v1.5.9.0 Information is subject to change without notice. Check local codes. Parted 12/04/2015 IYORK Guide Specification for York Sunline Page: 12 GENERAL Units shall be manufactured by Johnson Controls Unitary Products in an ISO 9001 certified facility. York Sunline units are convertible single package units. Although the units are primarily designed for curb mounting on a roof, they can also be slab -mounted at ground level or set on steel beams above a finished roof. Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory -mounted options and field -installed accessories to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power exhaust are suitable for bottom duct connections only. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. All non -Scroll compressors include crankcase heaters and all compressors have internal pressure relief. Every refrigerant circuit includes a liquid line filter -drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch. The unit control circuit includes a 75 VA transformer, a 24-volt circuit breaker and a relay board with a compressor lockout circuit, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All models are CSA listed. All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements carry a 5- year warranty. Aluminized steel and Stainless steel tubular heat exchangers carry a 10-year warranty. DESCRIPTION Units shall be factory -assembled, single packaged, Electric Cooling/Gas Heat, Electric Cooling/Optional Electric Heat, Heat Pump/Optional Electric Heat are designed for outdoor mounted installation. The 3 ton, 4 ton and 5 ton units shall have minimum SEER rating of 13.0 with heat pumps having a 7.7 H.S.P.F. The 6 Ton Cooling only or Cooling with Electric Heat shall have 11.2 EER, 6 Ton Cooling with Gas Heat shall have 11.0 EER. They shall have built-in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R-410A refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units the cooling performance shall be rated in accordance with DOE and AHRI test procedures. Units shall be CSA listed, classified to ANSI Z21.47, UL 1995/CSA No. 236 standards. UNIT CABINET Unit cabinet shall be constructed of galvanized steel, with exterior surfaces coated with a non -chalking, powdered paint finish, certified at 1000 hours salt spray test per ASTMB117 standards. Indoor blower section shall be insulated with a minimum 1/2" thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be "large" size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 1" filters shall be furnished and be accessible through a removable access door, sealed airtight. Units filter track shall be designed to accommodate either 1" or 2" filters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air by-pass of the coils. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self -draining standards. Condensate connection shall be a minimum of 3/4" I.D. female and be a ridged mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY The indoor fan shall be a factory installed direct -drive or belt -drive assembly that includes an adjustable pitch motor pulley. Job site selected (B.H.P.) brake horsepower shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double -inlet type with forward -curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fan shall be of the direct -driven propeller type, discharge air vertically, have aluminum blades riveted to a corrosion resistant steel spider bracket and shall be dynamically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings, internally protected against overload conditions and staged independently. Unitary Sales Toot v1.5.9.0 Information is subject to change without notice. Check focal codes. Printed 12;04 (2015 YORK` Guide Specification for York Sunline Page: 13 REFRIGERANT COMPONENTS Compressors: a. Shall be internally protected with internal high- pressure relief and over temperature protection. b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Evaporator coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator coils shall be of the direct expansion, draw-thru design. c. Condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed or Micro -Channel aluminum tube, aluminum fins. d. Condenser coils shall be of the direct expansion, draw-thru design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent fixed -orifice or thermally operated expansion devices. b. Filter drier/strainer to eliminate any moisture or foreign matter. c. Accessible service gage connections on both suction and liquid lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. d. The refrigeration system shall provide at least 15°F of sub -cooling at design conditions. Unit Controls: a. Unit shall be complete with self-contained low -voltage control circuit protected by a resettable circuit breaker on the 24-volt transformer side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor. c. Loss-of-charge/Low-pressure switch. d. High-pressure switch. e. Freeze -protection thermostat, evaporator coil. j. f. Unit shall incorporate `AUTO RESET' compressor over temperature, over current protection. g. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. h. Unit control board shall have on -board diagnostics and fault code display. i. Standard controls shall include anti -short cycle and low voltage protection, and permit cooling operation down to 0°F. Control board shall monitor each refrigerant safety switch independently. k. Control board shall retain last 5 fault codes in non volatile memory which will not be lost in the event of a power loss. GAS HEATING SECTION (SINGLE STAGE) Shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. Venter wheel shall be constructed of stainless steel for corrosion resistance. The heat exchanger shall be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 25°F. Burners shall be of the inshot type, constructed of aluminum coated steel and contain air mixture adjustments. All gas piping shall enter the unit cabinet at a single location through either the side or curb without any field modifications. Integrated control boards shall provide timed control of evaporator fan functioning and burner ignition. Heating section shall be provided with the following minimum protection. a. Primary and auxiliary high -temperature limit switches. b. Induced draft motor speed sensor. c. Flame roll out switch. d. Flame proving controls. e. If any of the above safety devices trip, a LED (light- emitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage, 40% Capacity 2nd Stage. UNIT OPERATING CHARACTERISTICS Unit shall be capable of starting and running at 125°F outdoor temperature, exceeding maximum load criteria of AHRI Standard 210/240. The compressor, with standard controls, shall be capable of operation down to 0°F outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up (Gas heat only). Untttar, Sales Tool v1.5 9.0 Information is subject to change without notice. Check local codes. Printed 12/0412015 �YORK Guide Specification for York Sunline Page: 14 ELECTRICAL REQUIREMENTS All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES • Compressor 5 Years • Heat Exchanger 10 Years • Electric Heat Element 5 Years • Other Parts 1 Year ADDITIONAL FACTORY INSTALLED OPTIONS FIELD INSTALLED OPTIONS • Roof Curb — 14" high, full perimeter curb with wood nailer (shipped knocked -down). • Barometric Relief Damper — This damper accessory can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. Unitary Sales Tool v1.5 9.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015 _II SHUTLER CONSULTING ENGINEERS, Inc. 12503 Bel -Red Road, Suite 100 Bellevue, Washington 98005 (425) 450-4075 FAX (425) 450-4076 JOB UBS T.I. SHEET NO. COVER OF CALCULATED BYjch CHECKED BY SCALE JOB NUMBER 15-41.02 DATE 1/18/2016 DATE STRUCTURAL CALCULATIONS FOR: NEW HVAC UNITS -- UNIVERSAL BUILDING SYSTEMS 14520 INTERURBAN AVE. SOUTH, SUITE D-100 TUKWILA, WASHINGTON PROPOSED BY: UNIVERSAL BUILDING SYSTEMS DESIGN CRITERIA: CODE ROOF LIVE LOAD WIND LOAD SEISMIC ZONE y,IEWED FOR MOMPLIANCE APPROVED JAN 2 8 2016 INTERNATIONAL BUILDING 25 PSF SNOW LOAD, Is=1.0 110 MPH ZONE, EXPOSURE 'B', Iw=1.0 SITE CLASS 'D', Sds=0.985, ap=2.5, Rp=6.0, Ip=1.0 CORRECTION MI5-ols7 City of Tukwila N2GE�IVISI • N RECEIVED CITY OF TUKWILA JAN 192016 PERMIT CENTER SHUTLER CONSULTING ENGINEERS, INC. 12503 Bel -Red Road, Suite 100, Bellevue, WA 98005 * (425) 450-4075 * FAX (425) 450-4076 1-18-16 Ken Lorenz Universal Building Systems 14520 Interurban Ave. South, Suite D-100 Tukwila, WA Re: HVAC Units Ken, I have reviewed the information provided regarding the two hvac units installed on the roof the building above your space. The units have already been installed per the support details on the construction drawings for the building. The units are approximately 45" wide by 82" long by 33" tall and sit on a factory curb. The weight of the units is either 649 lbs or 621 lbs, depending on the unit. No curb information was provided, but I have used an allowance of 100 lbs. The makes the maximum load of the unit approximately 750 lbs. The construction drawings, prepared by Coughlin Porter Lundeen and dated March 27, 2014, show that the units would be supported by 5x5x3/8" angles. The factory curb is screwed to the roof deck and the unit is attached to the factory curb. I have reviewed the support angles and the existing roof joists and found them to be structurally adequate to support the units. If you have any questions or need additional information, please give me a call. Sincerely, bt,„It4 Headland, P.E. SHUTLER �- CONSULTING ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 JOB SHEET NO. CALCULATED BY DATE SCALE OF Hee -/f9 • P'' " larfilitumnir minim 11,1 111 i 4 ,a, SHUTLER _�- CONSULTING ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 425) 450-4075 FAX (425) 450-4076 JOB SHEET NO. CALCULATED BY DATE SCALE OF /-/(p-i0 4- Fa ")e33 cpa HO " awe 140 1 .. 74 I4a -1 I= IBM • MN SHUTLER CONSULTING ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 JOB SHEET NO. CALCULATED BY DATE SCALE vim -141-# /'/4'-/0. OF SHUTLER CONSULTING ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 JOB 0-& 4 SHEET NO. CALCULATED BY DATE SCALE OF r/, Ceittkittr tfo J d71 eot-- Ya (lad 1 *** `9c - uuoCAAO 4 fi to& L} -f l S?r`4T) '(1 ) Screw and Weld Capacities Screw Capacities ( '3Ie Notes ,. Capacities based on AISI S100 SectionE4. 2. When connecting materials of different steel thicknesses or tensile strengths, use the lowest values. Tabulated values assume two sheets of equal thickness are connected. 3. Capacities are based on Allowable Strength Design (ASD) and include safety factor of 3.0. 4. Where multiple fasteners are used, screws are assumed to have a center -to -center spacing of at least 3 times the nominal diameter (d). 5. Screws are assumed to have a center -of -screw to edge -of -steel dimension of at least 1.5 times the nominal diameter (d) of the screw. 6. Pull-out capacity is based on the lesser of pull-out capacity in sheet closest to screw tip or tension strength of screw. 7. Pull -over capacity is based on the lesser of pull -over capacity for sheet closest to screw header or tension strength of screw. 8. Values are for pure shear or tension loads. See AISI Section E4.5 for combined shear and pull -over. 9. Screw Shear (Pss), tension (Pts), diameter, and head diameter are from CFSEI Tech Note (F701-12). 10. Screw shear strength is the average value, and tension strength is the lowest value listed in CFSEI Tech Note (F701-12). 11. Higher values for screw strength (Pss, Pts), may be obtained by specifying screws from a specific manufacturer. h c Mils) Desrgn S a Tensile Th din fU I Shear Scre ' , PuII rout Allowable Head Pu I Over Pss 12781bs, ( , Shear,. Screw cz,)l; , Connection ) 5861bs Pull Over Capacity (Pss=16441bs, , • , Shear Fi5T1t`111"4 -t (Ibs) =11581bs) Pull Over (Pss 23301bs, 0 216" Pts = 2325 Ibs dia 0 340" Head Zi'E (Pss 30481bs Pts = 32011bs) 0 250" dia •0 409" Head Pts , Pull -Out Pts ,la, , . , Pull -Out ; Shear, _ pull -Out Pull , -Over Shear Pull Out mr�• PuII;Over 18 ";~e27 30 0.0188 33 T U,0283 ,5 33 0.0312 33 33 �_ . 33`., 33 44 82_, 95 24 f;37;,' 40 84 ,' 127 -= 140 48 ,89 f 103 29 _ 43;: 48 84 127 ;' 140 52 96 111 33 _ 50 55 105 _ 159 ` 175 55 " 102 118 38 .,57 63 105 159 175 60 :110 127 44 66 ' 73 127 . 191 211 i 33 µ43 . ' 54 68 , ,.,, 97 118 0.0346 .r%r 33 0.0451 33 -0 0566 '. '` 33 0.0713. 33 -. 0.1017 . ' 33 0.1242 33 45` 45 . �. 45 45 ,45 • 45 151:, 214 -_61 ". 79. :100„- 125 ,140 : 140 ,140 .- 140 140 �:;- 140 940 140 ' 164y -, 244 344 426 ,426: 426 72 _ '. 94 118 149 , ;195 195 195 195 195 _ 195 195 195 ' :177 ""' 263 370 523 54 8 °. 548 1 84 :: 109 137 173 246 301 265 '. 345 - • 386:_ 386 386 .:` 386 :: 188 : _ 280 , 394, 557 , 777 ; 777 ;s195 . 124 � 156 196 -; 280 . 342 ;'_265 345 ._ 433 545 .= 775 , t 775 •-;203 302 , .•424 600 ;1,016 1,016 �110 144 180< 227 4 324 396 ? _318 ' 415 .'. 521 656 936 . 1,067 ;� 214, 214 214a 214 'r`•54 68 i_ d ,"; 0.0566•', ;50 0.0713 50 0.1017 , . 50 0.1242 50 ,-';65;, 65 > - 65 65 214. 214 214, 214 r"140;-. 140 140 140 140. = 140 140 140 426 •; 426 426 -, 426 171 195 195 195 ' 195 195 195 195 534 548 548 548 198<'• 249 356. 386 z 386':. 386 386 386 `;` 569; - 777 .. 777 777 _ 225 284 ,405. , 494 •625, 775 775 775 "613" 866 1,016 1,016 r261_ 328 468 572 -752 948 1,067 1,067 Weld Capacities Table Notes 1. Capacities based on the AISI S100 Specification Sections E2.4 for fillet welds and E2.5 for flare groove welds. 2. When connecting materials of different steel thicknesses or tensile strengths, use the lowest values. 3. Capacities are based on Allowable Strength Design (ASD). 4. Weld capacities are based on E60 electrodes. For material thinner than 68 mil, 0.030" to 0.035" diameter wire electrodes may provide best results. 5. Longitudinal capacity is considered to be loading in the direction of the length of the weld. 6. Transverse capacity is loading in perpendicular direction of the length of the weld. 7. For flare groove welds, the effective throat of weld is conservatively assumed to be less than 2t. 8. For longitudinal fillet welds, a minimum value of EQ E2.4-1, E2.4-2, and E2.4-4 was used. 9. For transverse fillet welds, a minimum value of EQ E2.4-3 and E2.4-4 was used. 10. For longitudinal flare groove welds, a minimum value of EQ E2.5-2 and E2.5-3 was used. �r _ am) Allowable Weld Capacity (Ibs / in) ongitudinal an a(c7,trcA5Tl4 N Longitudinal i'r'AF�L3CY3 43 0.0451 U.0566 :; .... 0.0713 0.1017 _ 33 33 33 45 45_.. 45 45 499 626 789 1125 864 084., 1365 ,1269 ,544 859 663 1048 54 97 0.0566, 0.0713 0.1017 50 _.. 65 50 65.. 50 65 905 1140 1269 1566 1972 1269 985 1241 1202 1514. .1 2We/d capacity for material thickness greater than 0.10"requires engineering judgment to determine /eg of welds, WI and W2. rn -_ SHUTLER •- CONSULTING JOB U I�' _ ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 SHEET NO. 5-5 CALCULATED BY OF DATE / /LY 4' SCALE i ii4 IMEMMEM OP IIIIIIIIIIIIIIIIIIIIff Jill .......prmai.....ml....." m. 07. I p Roof Top HVAC Unit - lateral loads Seismic - Sas 'y0985 _7 Shc . ;{0 553' r Fp 0.493 wt Wind - Speed 110 mph Exposure B qZ 18.43 psf ap Rp 'p KZ '0.70''� Kn"100 Kd 0;85 ., [.':.1.00 Fp-ws 21.0 psf GCr - horiz. F„-ws 16.6 psf GC,- vert. iviapa ouiiuiiaiy 'wpm' nup:I/enpz-eartnqualce.wr.usgs.gov/aeslgnmaps/us/summary.php'/temp... ag Design Maps Summary Report I User -Specified Input Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available In 2008) Site Coordinates 47.48°N, 122.26°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III USGS-Provided Output Ss = 1.478 g S1 = 0.553 g SMs = 1.478 g SMl = 0.830 g Son = 0.985 g Sol = 0.553 g For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. . ■ H MCER Response Spectrum 1.65 1.50 1.35 1.20 1.05 0.90 0.75 0.60 0.45 0.30 0.15 0.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.20 Period, T (sec) 2.00 1.10 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00. 0.00 Design Response Spectrum 0.20 0.40 0.60 0.80 1.00 1.20 Period, T (sec) 1.40 1.60 1.80 2.00 Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. l of 1 8/29/2015 10:15 AM I 0 a o O L 3 p 'a X m E z mz ....��CQ °73 3 m alsRg Bungle lesieniun -I A O O A O CD O O co 7 1 C) m E +''`wco m — CO O O CD Sq ca I- n m o CI IZ zm Z CD COcri Cat, Z 000 3?0 0 0 =0 z D r c. t0 C)aN 0000W -9m 0onJ) 3m O O A T O 0a) 0 (rv(�f Z O 0 (i C W vi o Om �� O O N Er 0 41.16; CD („ r 0 0 CO m 11) O 00 m< co co O? 0 oCO n cr. co O OCD O OOD OJ X mox»mo O -2't0 3o O O O O 0 co N — 1 D 0)0CD o gA.jcoW O V O 00 - m D 0) O O • O 0 uC CD 0 -I.0 o v c o 0. m z N t&) n CO 00 O 0(0 �n w 00 0 0w W—o enol puee0 V 01 A CO C) CO • o O wa > r po +0 cu a w A A c C— C m 0 • 0 00 w Om - • O0CCD n°') 0 COOW00 �.m.3 cug mm C 3 3®C K <m a ®3 cn M-ur a 0) 5>M-o*0023tnc)Z ' .6 `73 m a mn�o--;.IL >=:7=...-Q-I—r0mOam00nCD En" Oav(O m2U N~=m=Nm70 ....eamm03 m 0 00mD 0_�mr a v ®a �c�m V. < w rc n m o o n n CO m m��=m Q m CD1 o ID Nma C .. mE m m nmO la• m- -! o 91 CO NWA v -a -.A CO +-o Dam z �� G)0 00CD - O OADO0)OO) -10000W N000 IT C' 0m v. la A rn� co O NWA co - - .- 01 O oz a) CO m 0) to to Av CO CO • — N—.N� -.4 00000WOOOVO CD CO CD cn Av000(0W NW00 =. .m.. O °0 W O O A O 00000000000 "4 - WO)V W0O OOW CO CCD ▪ NJ CDC,3i N W co NJ N A -4-v�p CO CD V OO 000 W -4,..-cc) — Cm 3V-a0m00Na O O OCD _, (0(co A0000 co 000 ?® m m 0 _ a VCn -e. CD (D� C 0 _ c�ID tli v ▪ Co 3 O 0 O00 CD AAV 01 -• , 0 O0 W la) CCOOO ... .... G) O 3 Q >aX °Q®CCaSc=0. am Ra�oCD5 C a. 75S0 mS.+p a.', _.�mr> • �y mmm=ymao t( m m 00..E O ✓ x� CD m xm m a » » tz m cD X- 13 N CO CO CO 000CD <_= Iea�14nS mar O 0CD a O O O O speol IeuasxuI (i5 DTa*L�G1X m off- �! (— a-moa°'yNo �. D 331 y 0 cn cn _.m O C) 0� Z m 0 3.. 7 0 0 7 '..yo • Xi u o o o r°/r Cp O o 7 0 CO N O CO m 10 N W N Cr) Z CO Cif ®a > 0 0A (J AA ..m CD s-4, fD O CD O O _ tD 9 O W CD CO CO 0000 3 0 m A- )1dad 3OVdS 013 0.) N o 1 0 7 r o O CM a CO to aw wrn WNa o y 0 —? C�7 � A v C m m N O W co co co O 0 7 m CG X N O O 000 W O O 00 O 000 01_.0 W CD cn COO CDC) CD D0 7C O- -17 O O O OOO6O coCD O 000 -a-a -s00(cn O NOO .-. C O 00 000jVO OO 0000 0V A) OV .Is WOO a ga O 0 0 000 _.O 0 0 0 000 O 0000 CO O)COCA O rt W. c 3 2 ® ? 3 p .'l' D 0 = v CD N3 CO A A O 0 CO A N W C OCn i N3 co O) co O co (Ot0 I m Wco.mo. in N N D CO CD CDC° S)13 ONI2133NION3 too I mX 3�..� n ® � m=mm�m-3 ,,'3 m mN«m ni m m� w 'O 3 3 3 3 m � C 0 XI a f > rn o C) A CAW Ca 00 - O -,. - CO CO (O O 00000)OON AA 0 00WD 0m I A (.4 CO W m - 0 COO CD 0000 W• 00NAA O 00 Co SMO-Id211V z 0 a 3 71 -11 71 .a .a ,a CO 3 = CD m CO n -12 030CCD 0 0 C 3 0 0 -C -C -4Cn- 0 00 NN N CO3 0 0 0 A CO co O( C 2 m CD 0) CD -I .mi OOO WCD CD of Er O 00 A V -4 (.)CCD S321f11b113dW31 N N 0 pry ort m�, o 0 _0 -Tm Z0: 0 CD C) 0 m c o CD 0 Z o 3 3 CC m o •swe slag 6uons Iesion!un 0 ° 7 ® m C1 CD o T W �— (D N m0 0 0) 7' (D n 0 CO Dr C c A U co O co � 7 v N N m 0 CD W N N O O N cm 1 w o ow o 2. OD 0 O fD 7 0 n fl) so o rn c) pap - in O O r O ODOo \_ 0 0or xi a. mpoo-ova-—v�'O ° o 0 ° m —16 co co cn CO W cam O CTONO NO w O N O 0 > 0 0 O CD CD o D 5i x —m cn u p) co) m o v c "3 CD Q. m > Z 00 (T (T m 0 N 00 O ON K bo00 00b3 00-0 co2. am N m V CD 2.60 m 00 O OOD 3 *2 CD CD o CD m0 CD CD 0 Oa) o Z v> ® c 91 CD _2= 0 OO O OA CD CD O OCO moo I'0 c 3cocx<®a®c CoKvr» cn3D71v00xcncnc Q.sZ Trim a°)a3 �t0 0 -m m o v0-'oc�c'Nnmm° o DVD°:===N�m�� o °1=: :3o°=o00: r. S T m n r -0 11 ®s-» .—..0 0 ii a II 0 �m0 m v proms �ym�c v D) v ° a OCD am y °: 0. CO CO. N 0) m V = CD 'so -a ...A0 D3 W CT O CJ) O V CT O CD +V = N r cw3 0 w (,)) w w( W o CW)1 CD E D) (mi O OOA A V�V N VOO 0000000 =. 0 Cl) fD o = D so -p 0 N 0 +g co A cocnm N O m C CT O 00 0 OA 0000 O VOOAOO 7' rn F 2 2 ha -a -a Ms..0A) — O) Om° (O cn� O� OC C)) NivCT A W 0) in CCa (O 0 O WC) Ca lV CD W Ca CT AO ECO CO NV CO 000000000 WO A V-aV W VOO_aCD CT OAOO Dm — CT ti, 0 CO O ° Ca) O 000000000N0 v NWN -a-aOO-aW-a-aA00 e M 0 W O Ca 0 V CT-, 0 (0 CA-coW V -•A� V as OANN O& A Ca COCTW ha CD V -a ha C a n N O O O V Cn V Pa V O A O co Co CTN 0000 7'® 0 0 'v m CD -o3 O CT ha PaA — N e a 7 O O OO-a V ACOA NNOONW-aCT0CDC, •► CD c a�Ds- a 7 (P CO 3-0r 3 y® Q�'Omr n CD=3 c yNm Q .. I. O m ®y a 01m Cr 0-00 .... o D� =®m.►�-1cr 0 aN c ~ , ID It II CD 0 vv°:g ° Q Q- II v x- .=i CD . 0 Q. V CDm c v 4- w CT V m 0 CD O O O O O O O CO O 00000 0 co O O 0 O 00 00000 CTO o 000 O 00 OOONO 'cob O 000 O CD CD OOOCTO o -AO O CD CD speol Me UGU!' m c 31ao 0),EE0 77(-7�00 m O Z_ � N om/) O G ,G O O (D 00 0oOfna�® m Z 7 0 T0 Onn o o n 0 00 a m 0 v o o CL 01 (.3 (T NNN V �-co�A A A V CT O CO A O CON W 0000 4 w A 61 Da Da CD V CO In A CT A A V O) O N FAO -'CON W ONO0 W O CD CD A A O N O O W in NV A000O Co CT O CT CO 01 CT O CO00 ODCO moo) 0(0 CD CD CO C 3 m S N 7C D0 N 2 co 0 7 to 0 CD to )IV3d 1103 ONI1000 )IV3d 33VdS 013 )IV3d 1103 0NIld3H co O St Co CD 0 N 0 03 0 W CD CO CT ACo W V= A CTA CT C71o0 x CD 01 C31Om SNO ONI2I33NION3 CD CDC 3xCD-- ,=o m Dom')® o :0 0) x 3 S .► 3 C) 3, DJ 7C 7C�mpl = N—C3 T 33 C o ®,Z S- "E.7 7 = =3 a,N -, CD 77 ** a £ 0- 0 = 0 N IV Da Da°O O CO -a CO CO -CD-CT) CT 3 0 000V V0 CD co co O CO CO CO CI N Naha N .0m► CD 7 0000 V J OCD CO CO O COCO COCA SMO1dHlIV "nvii "1 73 Xi 73 u) .o+-IUD= = W F. 00 0 0 VV VCn� O 0 0 W N N V 3 O O O CD CD CT COm s CD 07 CD CT Co 000 CT co(D A5. O O O CT CT CT COm S321lid2I3dIN31 Cn N e-r `3 ;t1 00 m 3- 0 O C -0 y 3 0 City of Tukwila Department of Community Development December 14, 2015 BILL ALSEPT 3903 SMITH AVE EVERETT, WA 98201 RE: Correction Letter # 1 MECHANICAL Permit Application Number M15-0157 UNIVERSAL BUILDING SYSTEMS - 14520 INTERURBAN AVE S Dear BILL ALSEPT, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" to be stamped and signed. [Electronic copies shall not be approved.] (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. The Plan on M3 for the supply and return appear a little inconsistent with the Mezzanine and main floor mechanical system for RTU2. Also mezzanine return shows 12" CFM. Please clarify to indicate if the RTU2 is to supply only that portion of the main level and is that area combined with the other section of the main level. Clarify if the RTU2 duct shown on the mezzanine level is actually referring to the main level ducts. Verify the supply and return air are sized approximately equal. (IMC 403.1) 2. Notes indicating "Supply and Return" are somewhat confusing as all arrows point to all supply and returns. Please separate and clarify which is actually supply or return. 3. Clarify if the RTU1 is for both levels (main floor and mezzanine) 4. Sheet M4 is not consistent with this plan. I assume it is provided for the roof curb detail. Provide that clarification on the sheet. 5. Provide notes for commissioning, balancing, economizers and sizing calculations with information about the all mechanical systems and exhaust fan in a matrix or table with notes on the plan. If there are to be smoke detectors required, please specify. (2012 WSEC SECTION C407, C408 & IMC 403.1 & 606) Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)433-7165. Sincerely, Rachelle Ripley Permit Technician File No. M15-0157 PA9 City Of Tukwila 12-18-15 RE: M15-0157 Universal Building Systems 14550 Interurban Ave S. Response to Corrections letter #1 (1) Corrections, clarifications and changes have been made to sheet M-3 as requested. (2) Additional notes have been added to sheet M-3. Supply and return grills have been identified. (3) RTU-1 serves both levels north of grid C. RTU-2 is serves both levels south of grid C. (4) Sheet M-4 is used for curb detail reference only. (5) As requested information has been added to sheet M-3 The information above has been added to sheet M-3 along with revised load calculations and equipment submittals. Please let me know if you need additional information. Thanks Bill Alsept Williams Mech 425 754 8759 CORRECTION LTR# I&o's7 RECEIVED CITY OF TUKWILA DEC 18 2015 PERMIT CENTER City of Tukwila Department of Community Development December 29, 2015 BILL ALSEPT 3903 SMITH AVE EVERETT, WA 98201 RE: Correction Letter # 2 MECHANICAL Permit Application Number M15-0157 UNIVERSAL BUILDING SYSTEMS - 14520 INTERURBAN AVE S Dear BILL ALSEPT, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: KC ELLIS at 206-431-3677 if you have questions regarding these comments. • Provide structural calculations for roof framing at new HVAC units and seismic zone D2 tie downs. Calculations need to be wet stamped and signed by the engineer. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. M15-0157 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORM COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0157 DATE: 01/19/16 PROJECT NAME: UNIVERSAL BUILDING SYSTEMS SITE ADDRESS: 14520 INTERURBAN AVE S - SUITE 100 Original Plan Submittal X Response to Correction Letter # 2 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division ON Public Works n Fire Prevention Structural Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 01/21/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/18/16 Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1 -ICI' k_,0 Plan Check/Permit Number: ❑ Response to Incomplete Letter # Ei Response to Correction Letter # 1.. ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: 1c Ot5) Uk_\\ , ►rTh(-, Project Address: I (2 3 v?-Q . \ (Z 3 fk ) ri\i Contact Person: ¶-�� L4� Q�2_ Phone Number: 47 Summary of Revision: —JY-kc Cnc c s NS P•c_43�ST`=t� �N�PiL RECEIVED f TUKWILA JAN 19 2016 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: NI ---Entered in TRAKiT on PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0157 DATE: 12/18/15 PROJECT NAME: UNIVERSAL BUILDING SYSTEMS SITE ADDRESS: 14520 INTERURBAN AVE S Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: 11,E COW' L P4% tS Building Division IIII Public Works Fire Prevention Structural Planning Division Permit Coordinator a PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 12/22/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 01/19/16 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only l n CORRECTION LETTER MAILED: 1 ? )'I `(5 (ALDepartments issued corrections: Bldg - Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0157 DATE: 12/3/15 PROJECT NAME: UNIVERSAL BUILDING SYSTEMS SITE ADDRESS: 14520 INTERURBAN AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: r' Buildinglon Public Works n NPR Fire Prevention Planning Division Structural Permit Coordinator El PRELIMINARY REVIEW: DATE: 12/8/15 Not Applicable n (no approval/review required) REVIEWER'S INITIALS: Structural Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: DUE DATE: 1/5/15 Approved with Conditions Denied (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Fire ❑ Ping ❑ PW ❑ Staff Initials: I2/ 1 R/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /2- / _I15 Plan Check/Permit Number: Mic-0157 ❑ Response to Incomplete Letter # Tr Response to Correction Letter # ❑ Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: / 17 5-5-V 111 /A /j-1 [/t(/77,/ /9///-- Contact Person: /5/L / / %Z5j '7 Phone Number: f 2I5 759 67 Summary of Revision: C'L`iC//fC/9j?6/z-5--- W PERMIT CENTER Sheet Number(s): H- "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: tO—Entered in TRAKiT on (, )-4 WILLIAMS MECHANICAL INC Page 1 of 3 Home : Espanol : Contact Safety & Health Washington State Department of Labor & Industries Search L&I A-Z Ind( Claims & Insurance Workplace Rights WILLIAMS MECHANICAL INC Owner or tradesperson Principals WILLIAMS, BRADLEY PATRICK, PRESIDENT WILLIAMS, DEBORAH KAY, SECRETARY WILLIAMS, DEBORAH KAY, TREASURER WILLIAMS, DEBORAH KAY, AGENT ZUCCARINI, MICHAEL J, AGENT (End: 01/01/1980) Doing business as WILLIAMS MECHANICAL INC WA UBI No. 601 413 863 3903 SMITH AVE EVERETT, WA98201-4549 425-303-0828 SNOHOMISH County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. WILLIMI088PA Effective — expiration 10/01/1992-10/01/2017 Bond Merchants Bonding Co (Mutual) Bond account no. WA33987 Received by L&I 09/23/2014 Active. Meets current requirements. $12,000.00 Effective date 10/01/2014 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601413 863&LIC=WILLIMI088PA&SAW= 1/29/2016 ABBREVIATIONS GENERAL NOTES GENERAL NOTES, CONT. SYMBOL LEGEND DRAWING INDEX & Q +/- R SQ NC ACC AdOUST ACT AD, ADO AD) AFP AHU ALUM APFROX ARdH ASTM BD BLDG BO BOT BR CB CIP CFCI CG CJ CLG CLR CMU COL CONC COND CONN CONT CPT CT CTR D DA DBL DD DTL DF DIA DIAG DIM DISP DN DR DS DW DWG E EA EF EXP EXP JT EL ELEC ELEV EOS EP EQ EQUIP EXIST EXT F FA FD FDN FE FEC FF FF&E FHO FIN FLASH FLR FDN FO FOIC FOIO FT FTG FURR GA GALV GFRC GL GSF GYP GWs HI3 HC HD jDWE ISM HORIZ HR HT 1-IVAC IBC ID IN INCL INSUL INT AND AT CENTERLINE NUMBER PLUS OR MINUS PROPERTY LINE SQUARE AIR CONDITIONING ACCESSIBLE ACOUSTICAL ACOUSTIC CEILING TILE AREA DRAIN ADDENDUM ADJACENT ABOVE FINISHED FLOOR AIR HANDLING UNIT ALUMINUM APPROXIMATE ARCHITECTURAL AMERICAN SOCIETY FOR TESTING AND MATERIALS BOARD BUILDING BOTTOM OF BOTTOM BEDROOM CATCH BASIN CAST IN PLACE CONTRACTOR FURNISHED CONTRACTOR INSTALLED CORNER GUARD CONTROL JOINT CEILING CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONDITION CONNECTION CONTINUOUS CARPET CERAMIC TILE CENTER DEEP/DEPTH/DRYER DOUBLE ACTING DOUBLE DECK DRAIN DETAIL DRINKING FOUNTAIN DIAMETER DIAGONAL DIMENSION DISPENSER DOWN DOOR DOWNSPOUT DISHWASHER DRAWING EAST EACH EXHAUST FAN EXPANSION EXPANSION JOINT ELEVATION ELECTRICAL ELEVATOR EDGE OF SLAB ELECTRIC PANEL EQUAL EQUIPMENT EXISTING EXTERIOR FEMALE FIRE ALARM FLOOR DRAIN OR FIRE DEPARTMENT FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR FURNITURE, FIXTURE & EQUIPMENT FREIHEIT AND HO ARCHITECTS FINISH FLASHING FLOOR FOUNDATION FACE OF FURNISHED BY OWNER INSTALLED BY CONTRACTOR FURNISHED BY OWNER INSTALLED BY OWNER FOOT/FEET FOOTING FURRING/FURRED GAUGE GALVANIZED GLASS FIBER REINFORCED CONCRETE GLASS GROSS SQUARE FOOTAGE GYPSUM GYPSUM WALL BOARD HOSE BIB HOLLOW CORE HEAD HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT/HIGH HEATING, VENTILATION AND AIR CONDITIONING INTERNATIONAL BUILDING CODE INSIDE DIAMETER INCH INCLUDED/INCLUSIVE INSULATION INTERIOR JAN JT L LAM LAV LB LF LT M MAX MECH MTL MFR MIN MISC MO N NFPA NIC NO NOM NTS OC OD OH ORD OPNG OPP OTS PCC PERIM PLAM PR PREP PSF R RAD RCP RD REBAR REF REFR REINF REQD REV RM RO S SC SCHED SD SEC SF SHT SHTG SIM SPEC SQ SSTL STD STL STOR STRUCT SUSP SYM SYS TEL TEMP THK TO TOC TOS TOW TRAN TV TYP UL UNO VCT VERT VEST VOL W W/ W/O WC WD WIND WH WO WR WRB WT JANITOR JOINT LENGTH/LONG LAMINATE LAVATORY POUND LINEAL FOOT LIGHT MALE MAXIMUM MECHANICAL METAL MANUFACTURER MINIMUM MISCELLANEOUS MASONRY OPENING NORTH NATIONAL FIRE PROTECTION ASSOCIATION NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETER OVERHEAD OR OPP HAND OVERFLOW ROOF DRAIN OPENING OPPOSITE OPEN TO STRUCTURE PRE -CAST CONCRETE PERIMETER PLASTIC LAMINATE PAIR PREPARATION POUNDS PER SQUARE FOOT RISER RADIUS REFLECTED CEILING PLAN ROOF DRAIN REINFORCING BAR REFERENCE REFRIGERATOR REINFORCED/REINFORCING REQUIRED REVISED/REVISION ROOM ROUGH OPENING SOUTH SCALE SCHEDULE STORM DRAIN SECTION SQUARE FEET SHEET SHEATHING SIMILAR SPECIFICATIONS SQUARE STAINLESS STEEL STANDARD STEEL STORAGE STRUCTURE/STRUCTURAL SUSPENDED SYMMETRICAL SYSTEM TELEPHONE TEMPORARY THICK/THICKNESS TOP OF... TOP OF CONCRETE TOP OF SLAB TOP OF WALL TRANSITION TELEVISION TYPICAL UNDERWRITERS LABORATORIES, INC. UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL VESTIBULE VOLUME WEST WITH WITHOUT WATER CLOSET WOOD WINDOW WATER HEATER WHERE OCCURS WATER RESISTANT WATER RESISTANT BARRIER WEIGHT C:\Users\zadams\Documents\A15-280 Universal Building Systems CENTRAL_ebrouillette.rvt 1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2012 INTERNATIONAL BUILDING CODE AS ADOPTED BY THE CITY OF TUKWILA, STATE REGULATIONS FOR BARRIER FREE DESIGN, WA STATE ENERGY CODE, AND ALL APPLICABLE LOCAL CODES, ORDINANCES, AND STANDARDS. IN CASE OF ANY CONFLICT WHERE THE METHODS OR STANDARDS OF INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES SHALL GOVERN. NOTIFY THE ARCHITECT OF ALL CONFLICTS. 2. SECURE RELEVANT CITY AND STATE APPROVALS RELATING TO FIRE, CONSTRUCTION, LABOR, HEALTH AND LICENSING. CONTRACTOR SHALL FURTHER POST ALL BONDS AND SECURE ALL INSURANCE REQUIRED BY LAW OR CONTRACT, FORWARDING PROOF OF SUCH ACTIONS TO THE LANDLORD PRIOR TO COMMENCEMENT OF CONSTRUCTION. 4. WORK NOT INCLUDED IN THIS CONTRACT SHALL BE MARKED "N.I.C." OR SPECIFICALLY ASSIGNED TO ANOTHER PARTY. 5. CONTRACTOR SHALL VISIT THE SITE, REVIEW THE DRAWINGS AS SUBMITTED BY THE ARCHITECT, AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO BIDDING OR CONSTRUCTION. 6. ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURERS LATEST RECOMMENDATIONS OR WRITTEN DIRECTIONS. 8. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 9. WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR, IT IS INTENDED THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES, ITEMS OR PARTS AS ARE REQUIRED TO PROPERLY COMPLETE THE WORK. 10. VERIFY ALL "BUILDING STANDARDS" WITH BUILDING OWNER PRIOR TO BEGINNING ANY WORK. HOWEVER, THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS WITHOUT THE ARCHITECTS WRITTEN APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEND, INDEMNIFY, AND HOLD THE ARCHITECT HARMLESS FROM ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. 12. LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THIS WORK. 13. VERIFY AND CONFORM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UNLESS OTHERWISE NOTED IN THE PLANS OR SPECIFICATIONS. 14. ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN (BROOM) CONDITION AT ALL TIMES. 15. PROTECT ADJACENT WORK AND REPAIR ANY DAMAGE AT CONTRACTOR'S OWN EXPENSE. 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH ALL APPLICABLE SAFETY CODES. 17. THE CONTRACTOR SHALL INDEMNIFY AND HOLD THE BUILDING OWNER/ARCHITECT/ENGINEER HARMLESS FOR INJURY OR DEATH TO PERSONS OR FOR DAMAGE TO PROPERTY CAUSED BY THE NEGLIGENCE OF THE CONTRACTOR, HIS AGENTS, EMPLOYEES, OR SUBCONTRACTORS. 18. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKERS. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS WELL AS ALL REVISIONS, ADDENDA, AND CHANGE ORDERS. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS, ON THE PREMISES AT ALL TIMES WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. 19. MAINTAIN ALL EXIT PATHWAYS DURING CONSTRUCTION. 20. PROVIDE COMPLETE SECURITY OF THE TENANT SUITE WHILE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETED. 21. AT COMPLETION OF THE WORK, REMOVE ALL DEBRIS FROM THE SITE, LEAVING SPACE CLEAN, WASH ALL WINDOWS AND GLASS, POLISH ALL HARDWARE AND FIXTURES. REPLACE AND PATCH AREAS OF CEILING DAMAGED DUE TO LIGHTING INSTALLATION OR MECHANICAL ADJUSTMENT. 23. MINIMIZE DISRUPTIONS OF BUILDING OCCUPANTS DUE TO NOISE, ODOR, FUMES, OR VIBRATION. AT THE END OF CONSTRUCTION THE CONTRACTOR SHALL COMPLETELY CLEAN ALL AREAS SOILED BY CONSTRUCTION ACTIVITIES INCLUDING THOSE IN WHICH NO WORK WAS DONE. 24. LATHING, PLASTER, AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO CHAPTER 25 OF THE 2012 I.B.C. 26. ALL GLASS AND GLAZING SHALL COMPLY WITH CHAPTER 24 OF THE 2012 I.B.C. AND THE U.S. PRODUCT SAFETY COMMISSION: SAFETY STANDARDS FOR ARCHITECTURAL GLAZING MATERIALS (42 FR 1426: 16 CFR PART 1201). 27. VERIFY ALL DOOR AND WINDOW ROUGH OPENING DIMENSIONS WITH DOOR AND WINDOW MANUFACTURERS. 28. DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONSTRUCTION DRAWING SHOULD BE CALLED TO THE ATTENTION OF THE ARCHITECT. 29. CONSTRUCT WALLS PLUMB AND SQUARE WITH EXISTING STRUCTURE AND NEW CONSTRUCTION UNLESS NOTED OTHERWISE. 30. COORDINATION: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION AND COORDINATION OF THE WORK OF ALL TRADES TO ASSURE COMPLIANCE WITH THE DRAWINGS. 31. ANY DEVIATIONS FROM DIMENSIONED LOCATIONS MUST BE APPROVED BY THE ARCHITECT. DIMENSION: 1. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND DIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN PRIOR TO PROCEEDING WITH THE WORK. 2. DIMENSIONS OF PLANS ARE TYPICAL TO THE CENTERLINE OF COLUMNS AND FINISHED GWB FACE OF PARTITIONS, UNLESS NOTED OTHERWISE. DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS ARE TO BE FOUR (4) INCHES FROM THE FACE OF THE ADJACENT PARTITION OR CENTERED BETWEEN PARTITIONS. 3. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY THE ARCHITECT IF DISCREPANCIES ARE FOUND. CONSTRUCTION: 1. INVESTIGATE AND VERIFY LOCATIONS OF EXISTING STRUCTURAL, PLUMBING, MECHANICAL, AND ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS AND NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. 2. COORDINATE CONSTRUCTION SCHEDULING WITH THE BUILDING OWNER TO ALLOW ONGOING OPERATION OF THE FACILITY DURING CONSTRUCTION. 3. PROVIDE BLOCKING AS REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. 4. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. 5. PROVIDE GALVANIC ISOLATION BETWEEN DISSIMILAR METALS. 6. PATCH AND REPAIR ALL EXISTING SURFACES AS REQUIRED BY DEMOLITION AND NEW CONSTRUCTION TO RECEIVE NEW SCHEDULED FINISHES. ALL SURFACES ARE TO HAVE "LIKE -NEW' APPEARANCE. 7. STUD HEIGHT AND SPACING LIMITATION OF STEEL FRAMING COMPONENTS SHOULD BE IN COMPLIANCE WITH ASTM C 754 FOR MAXIMUM DEFLECTION AND MINIMUM LATERAL LOADING REQUIREMENTS. 8. ALL DEMOLISHED MATERIALS TO BE RECYCLED TO AN APPROVED RECYCLER. SUBMITTALS AND WARRANTY 1. SUBMIT A LIST OF PROPOSED PRODUCT SUBMITTALS AND SHOP DRAWINGS TO THE OWNER FOR APPROVAL PRIOR TO START OF CONSTRUCTION. 2. ALL PRODUCTS AND MATERIALS SPECIFIED IN THE DRAWINGS (WITH EXCEPTION TO SPECIFIC FINISH COLORS AND FLOORING) ARE INTENDED TO BE ON AN "OR EQUAL" BASIS. ANY PROPOSED SUBSTITUTIONS MUST BE SUBMITTED TO THE ARCHITECT IN WRITING FOR APPROVAL WITHOUT DELAY OF SCHEDULE. 3. ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER COMPLETION, UNLESS OTHERWISE SPECIFIED, AND SHALL BE SO STATED IN CONTRACTOR'S WRITTEN PROPOSAL AND AGREEMENT. ALL REPAIRS, CORRECTIONS, DISCREPANCIES, ETC., MUST BE MADE WITHOUT ANY ADDITIONAL COST TO THE OWNER, AND WITHIN FIVE (5) DAYS AFTER NOTICE IS GIVEN. PLUMBING, MECHANICAL & ELECTRICAL: 1. PLUMBING, MECHANICAL, & ELECTRICAL DRAWINGS ARE TO BE SUBMITTED UNDER SEPARATE PERMIT. 2. MECHANICAL & ELECTRICAL CONTRACTORS SHALL BE RESPONSIBLE TO MAINTAIN COMPLIANCE WITH APPLICABLE CODES AND STANDARDS AND OBTAIN ALL NECESSARY PERMITS AND APPROVALS. 3. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE BIDDER DESIGN/BUILD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THE CORRESPONDING PERMITS FOR WORK. THE PROPOSED SYSTEM DESIGN & METHOD OF OPERATION FOR ALL ROOMS SHALL BE REVIEWED AND APPROVED BY THE TENANT PRIOR TO THE START OF ANY WORK. 4. WHERE APPLICABLE, STRUCTURAL, PLUMBING, MECHANICAL, ELECTRICAL, AND FIRE PROTECTION DRAWINGS ARE SUPPLEMENTARY TO THESE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ALL DISCREPANCIES BETWEEN THE CONSULTANTS' DRAWINGS WITH A WRITTEN REQUEST FOR CLARIFICATION. ANY WORK INSTALLED IN CONFLICT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL BE CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO THE BUILDING OWNER, TENANT, OR ARCHITECT. 5. ALL CABLING AND WIRING NOT IN CONDUITS OR FULL SURROUND CABLE TRAYS SHALL HAVE A FLAME SPREAD RATING OF LESS THAN 25 AND A SMOKE DEVELOPMENT RANGE OF LESS THAN 50. 6. ALL EXPOSED MATERIAL & PIPING IN RETURN AIR PLENUM MUST MEET FS 25. 7. ALL PLUMBING AND HVAC PIPE AND DUCTWORK IN PLENUM SHALL HAVE A FLAME SPREAD RATING OF LESS THAN 25 AND A SMOKE DEVELOPMENT RANGE OF LESS THAN 50. FIRE PROTECTION: 1. IF NECESSARY, PROVIDE FIRE PROTECTION AT ALL PENETRATIONS OF FIRE RELATED ELEMENTS AS REQUIRED BY CODE. 2. FIRE EXTINGUISHERS: VERIFY LOCATION, TYPE, AND SIZE PER FIRE MARSHAL REQUIREMENTS. CONTRACTOR TO PROVIDE ALL TEMPORARY AND PERMANENT FIRE EXTINGUISHERS REQUIRED UNDER N.F.P.A. 10 MOST RECENT EDITION AND APPROVED BY THE FIRE MARSHAL. CONFIRM ACCEPTABILITY OF LOCATION WITH FIRE MARSHAL PRIOR TO INSTALLATION. PROVIDE FINISHED CABINETS TO MATCH BUILDING STANDARD FOR EXTINGUISHERS AT ALL EXPOSED LOCATIONS. 3. FIRE EXTINGUISHERS AND CABINETS SHOULD BE LOCATED SO THAT THE TOP OF THE EXTINGUISHER OR CABINET IS NO HIGHER THAN 48" AFF AND THE TOP OF THE EXTINGUISHER OR CABINET HANDLE IS AT LEAST 36" AFF. 4. AT SEMI -RECESSED FIRE EXTINGUISHER CABINETS WRAP ADDITIONAL LAYER(S) OF TYPE 'X' GYPSUM WALL BOARD INTO THE CABINET CAVITY TO MAINTAIN SPECIFIED FIRE RATED REQUIREMENT. REFER TO WALL CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. 5. PROVIDE AND INSTALL FIRE EXTINGUISHER SIGNAGE (5"X6') ABOVE EACH FIRE EXTINGUISHER OR CABINET WITHIN THE SCOPE OF THE TENANT IMPROVEMENT. MOUNT AT 84" AFF UNLESS OTHERWISE REQUIRED. 6. EXIT SIGNS AND EXIT ILLUMINATION SHALL CONFORM TO THE 2012 IBC AND THE CITY OF TUKWILA REQUIREMENTS. CONTRACTOR TO PROVIDE AND INSTALL EMERGENCY LIGHTING AND EXIT LIGHTING AS REQUIRED BY THE TUKWILA FIRE AND BUILDING DEPARTMENTS. CONFIRM ACCEPTABILITY OF LOCATIONS WITH THE BUILDING OWNER BEFORE INSTALLATION. CONTRACTOR SHALL PROVIDE AND INSTALL AUDIBLE ALARMS IN ACCORDANCE WITH IBC ARTICLE 9. ALARMSIGNALS AS REQUIRED BY ADA GUIDELINES. CONTRACTOR SHALL PROVIDE AND INSTALL VISIBLE Q I CONTRACTOR SHALL PROVIDE AND INSTALL ALL SMOKE DETECTORS AND SMOKE DETECTION AS REQUIRED UNDER ARTICLE 9 OF THE IBC. THE INSTALLATION OF THE ABOVE NOTED SYSTEM SHALL INCLUDE THE CONNECTION TO AND/OR MODIFICATION OF THE EXISTING BUILDING SYSTEMS, AS NECESSARY. 7. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 8. FLAMMABLE LIQUIDS SHALL NOT BE PLACED, STORED, OR DISPENSED IN THIS OCCUPANCY EXCEPT AS PROVIDED IN NFPA STANDARD 30 AND THE 2012 INTERNATIONAL FIRE CODE. PERMIT MAY BE REQUIRED. 9. ALL DRAPES, HANGINGS, CURTAINS, AND ALL OTHER DECORATIVE MATERIAL, INCLUDING CHRISTMAS TREES THAT WOULD TEND TO INCREASE THE FIRE AND PANIC HAZARD SHALL BE MADE FROM NONFLAMMABLE MATERIAL, OR SHALL BE TREATED AND MAINTAINED IN A FIRE RETARDANT CONDITION BY MEANS OF A FLAME RETARDANT SOLUTION OR PROCESS APPROVED BY THE FIRE MARSHAL. PROVIDE A CERTIFICATION TO THIS EFFECT. EXIT DOORS, EXIT LIGHTS, AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL. MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISHES SHALL BE PER TABLE 803.9, SECTION 803.1 OF THE 2012 IBC. 10. ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE SPECIFIC RATING. CEILING: 1. REFLECTED CEILING PLAN IS FOR THE GENERAL INFORMATION OF THE CONTRACTOR. EXACT LOCATIONS SHOULD BE VERIFIED. DOOR: 1. ALL DOOR HARDWARE TO MEET REQUIREMENTS OF 2012 IBC AND OWNER'S BUILDING REQUIREMENTS. 2. COORDINATE ALL KEYING REQUIREMENTS WITH OWNER/TENANT. CONTRACTOR SHALL PROVIDE ALL LOCKSET CYLINDERS TO MATCH OWNER STANDARD. CONTRACTOR SHALL RE -KEY ALL DOORS TO MEET TENANT AND OWNER'S REQUIREMENTS. FINISH AND MATERIALS: 1. SUBMIT FINISH SAMPLES TO TENANT AND OWNER FOR APPROVAL PRIOR TO ORDERING MATERIALS. 2. INTERSECTION OF SCHEDULED FLOORING MATERIALS ARE TO OCCUR AT CENTERLINE OF DOOR WHEN IN A FULLY CLOSED POSITION UNLESS NOTED OTHERWISE. 3. PROVIDE APPROPRIATE TRANSITION MATERIAL AS REQUIRED WHERE DISSIMILAR FLOORING MATERIALS INTERSECT. DETAIL NUMBER '`"-- SHEET NUMBER SECTION NUMBER SHEET NUMBER STORAG NO101 200 SF� ROOM NAME ROOM NUMBER SQ FOOTAGE g--- GRID BUBBLE NUMBERS @ VERTICAL GRID BUBBLE LETTERS @ HORIZONTAL GRID LINE 0 STUD PARTITION CONCRETE MASONRY PARTITION CONCRETE PARTITION DOOR REPRESENTATION DOOR NUMBER /- EQUIPMENT GROUP \"-- EQUIPMENT NUMBER �--- ELEVATION NUMBER SHEET NUMBER TRUE NORTH MASONRY STEEL SOIL CONCRETE RIGID INSULATION INTERNATIONAL SYMBOL: FIXTURE OR SPACE TO COMPLY WITH ACCESSIBLE DESIGN STANDARDS ANSI 117.1-2012 AND ADAAG SHEET NUMBER 00 - GENERAL SHEET NAME A0.00 COVER SHEET A1.00 CODE PLAN 04 - ARCHITECTURAL A2.00 SITE PLAN A3.01 FLOOR PLAN A5.00 STAIR ENLARGED PLANS & SECTIONS A6.00 DETAILS A6.01 DETAILS A6.02 DETAILS A7.00 REFLECTED CEILING PLAN A8.00 ENLARGED RESTROOM PLAN AND ELEVATIONS A8.01 INTERIOR ELEVATIONS A9.00 SCHEDULES STRUCTURAL S1.0 SPECIAL INSPECTION & GENERAL NOTES S2.0 PARTIAL FOUNDATION PLAN & MEZZANINE PLAN S3.0 MEZZANINE FRAMING SECTIONS SCOPE OF WORK TENANT IMPROVEMENT FOR AN OFFICE AND WAREHOUSE OF APPROXIMATELY 5,298 SQ. FEET IN AN EXISTING SHELL BUILDING. SCOPE INCLUDES INTERIOR PARTITIONS, (2) RESTROOMS, (2) STAIRS, MEZZANINE, AND DEMISING WALL. APPLICABLE CODES PROJECT DATA 2012 INTERNATIONAL BUILDING CODE WI WA STATE AMENDMENTS 2012 INTERNATIONAL EXISTING BUILDING CODE 2012 INTERNATIONAL FIRE CODE W/ WA STATE AMENDMENTS 2012 INTERNATIONAL MECHANICAL CODE W/ WA STATE AMENDMENTS WASHINGTON ADMINISTRATIVE CODE (WAC1 PROJECT ADDRESS: JURISDICTION: PARCEL NUMBER: LEGAL DESCRIPTION: ZONING: OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: SPRINKLERED: NUMBER OF STORIES: SQ. FT. OF BUILDING: SQ. FT. OF IMPROVEMENT: VALUATION: 14600 INTERURBAN AVE. SOUTH BUIDING D, SUITE #1 TUKW LA, WA 98168 CITY OF TUKWILA 3365901650 HILLMANS SEATTLE GARDEN TRS C/LI B (OFFICE) V-B YES 1 STORY + MEZZANINE 9,035 S.F. 5,298 S.F. $265,000.00 L` ceee mace Mate mace idea e mem Maas Bete ae a eaee caeca i 'a ea Ema aa6f.2 a ta mem a a2 a re a CUM alee.4 fame e2eci� fa ee mace n fuze Mae aaa CZ e2 Mai teem e£afa a e maw ae fe faGc'ca aem eff f2 fa ft ea a mace Maid CUE W. eieif2 caeca a2e2ee eaeaea tEa a am a,2a C2 MOM ea a Mfhtte tame eeeeCe MOO c a ea4f2 Cd a it a2e2 caeca as TEL: 425 827 2100 WA 198033 www.FHOARCH.COM Permit No. �� ¢ a 1/1 PERMIT SET IS s Plan review appro #! is subj t 4rrcis and omission!). a�a�� Approval of consirulction d cants t !Os not authoi zo cL ' the violation of t.ny adopted - tre r ctlinance. 1-'co; # of approved Field Copy and c +T :: ack Towi ;d4;:c is By: Date: / -29aza teem m City of taiia.1 BUILDING PktiSlip,N meta in as DEFERRED SUBMITTALS PROJECT TEAM THE FOLLOWING PORTIONS OF THE PROJECT WILL BE APPLIED FOR UNDER SEPARATE PERMITS: 1. ELECTRICAL SYSTEM WORK 2. HVAC SYSTEM (DUCTING, DISTRIBUTION AND CONTROLS) 3 PLUMBING SYSTEM 4. FIRE SPRINKLERS 5 FIRE ALARMS VICINITY MAP 0 OWNER: ARCHITECT: UNIVERSAL BUILDING SYSTEMS 800 SW 34TH STREET RENTON, WA 98057 CONTACT: KEN LORENZ FREIHEIT & HO ARCHITECTS 5209 LAKE WASHINGTON BLVD NE, SUITE 200 KIRKLAND, WA 98033 CONTACT: JOE PALMQUIST PHONE: (425)827-2100 STRUCTURAL: SHUTLER CONSULTING ENGINEERS, INC 12503 BEL-RED ROAD, SUITE 100 BELLEVUE, WA 98005 CONTACT: JOHN HEADLAND PHONE: (425)450-4075 CONTRACTOR: TBD REVISIONS No changes shall hn nride to the scope of work witho' s: Pr,Or P pprovI of ( ",7:n ruhmittc I BUILDING D ILA AREA OF WORK PERMIT CENTER mind a" aa GEe4f4 a ae a each fags mem GUM aNeEf2 edam cage meta ceafe mace exec teem e&eEa ac a ec aaCZ atm mem tame eaa eeee mem to e m 000. may a CC a a tip. feiVA a few sec; 14600 INTERURBAN AVE. SOUTH 0 U) a J 5 co ca a F- S 17PAft'\a i ,E4UIr1:7 FOR: ❑ Mechanical Eicctrica! t, Plumbing Gz.s Piping of ukt„,vi , REV DESCRIPTION DATE BLDG PERMIT SUBMITTAL 09/04/2015 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 8 2016 City of Tukwila BUILDING DIVISION COVER SHEET M-1 Williams Mechanical 3903 Smith Ave Everett,WA 98201 0 (3.1 (SP-02 0 SP-08 (SP-06 ) INTERNAL ROAD (SP-06 (SP-08 SITE PLAN Scale: 3/32" =11-0" RTU-1 I RTU-2 BUILDING "D" E7i> (SP-07 ESP-04 ) INTERURBAN AVENUE i INTERNAL ROAD C:\Users\zadams\Documents\A15-280 Universal Building Systems CENTRAL_ebrouillette.rvt SITE PLAN GENERAL NOTES 1. NO WORK OUTSIDE OF SUITE. SITE PLAN IS INCLUDED FOR REFERENCE ONLY. SITE PLAN KEYNOTE LEGEND KEYNOTE DESCRIPTION SP-01 (E) TRASH ENCLOSURE, TO REMAIN SP-02 (E) CONCRETE SIDEWALK, TO REMAIN SP-03 (E) LANDSCAPING, TO REMAIN SP-04 (E) FIRE HYDRANT, TO REMAIN SP-05 (E) TRANSFORMER, TO REMAIN SP-06 (E) BUILDING CANOPY ABOVE, TO REMAIN SP-07 (E) ACCESSIBLE PARKING STALL, TO REMAIN SP-08 (E) TENANT EXIT DOOR, TO REMAIN SP-09 (E) ROOF SKYLIGHT, TO REMAIN ,. .• DEC 01 2015 PERMIT CENTER C ' CE came caeca came 626262 MOO MEM OCEC.E MOM e,EeeE came CE a Cc caeca 6EeECE CE Cif; eE came CEOCE wee mem MOO teem OCHE came CE CHE eau fE CE C12 CEOCE eE eE eE MOM 'caeca MOM MCECST MUM eEa CE wee e$x� BE MO Ca Ea CE MOM CECEi CE CI! fa MOM BE CE BE caeca B Cee MOM ewe wee eE caeE caeca MOM CUM wee came 06262 MOO came eace eECECE caeca e e eE meEm tame CEem ca eye ca MOM (Eee BE eA eE cum eE C£ CE meta OWE fEBECL meFw. M EM MOM MOM eCECE 62626E tteaCd came came OCECE 62came 62 11E CEe&: eECECc eE ea ed ca ce eE MOM CCdC ite ft 0 caeca (EOM eee 62 CC CC MOO eEOCE MOO came C£CEC 620 Cd Ca Ce CE Cd eE MOM dCECE CEeed cam fa Cd CE Cd 626E CE CECECE MOM MOM MOM (EMU ea eE ea caeca CdCECE eaCE0 CEZE42 a2C,ECE CE 0 Cd CE CEBECE e2toCE CdCECE MOO CdCEC'E eECECE CcCEee 0 0 fa 8EC2CC eE0ca. czaeca ?EOM City of Tukwila caeca BUILDING DIVISION Ct eE CE �..-- TEL: 425 827 2100 5209 Lake Washington Blvd NE I Ste 200 I Kirkland I WA 198033 www.FHOARCH.COM CECEBE Cd6200 CECE CECECE came CdCdCC came MOM CECECE CdCEse wee edC REV DESCRIPTION DATE BLDG PERMIT 09/04/2015 REWIEOVED FOR CODE COMPLIANCE APPROVED JAN 28 2016 -2 Williams Mechanical 3903 Smith Ave Everett,WA 98201 o ,n (3 8" 240 CFM 8" 240 CFM Gas Sizing Per International Fuel Code Existing Unit Heater Additional MUA-1 MUA-2 TOTAL LOAD Existing 2 PSI gas meter 1" Line Capacity at 125 ft Table Capacity still Available 75,000 BTU 125,000 BTU 125,000 BTU 325,000 BTU 1,530,000 BTU 1,205,000 BTU Note American Meter regulators will be install on roof reducing 2" Gas Pressure to Standard inches water column with Vents to Atmosphere EQ 12'-0" REFLECTED CEILING PLAN - LEVEL 01 cm aoo Scale: =1'-0"7.00 Scale: 3/16" =1'-0" 8" 240 CFM ACT 2t4 410'.8' AFF ACT 2x4 410'40'AFF 6" 120CFM Type of 4 T- Stat RTU-1 18" 200 CFM EQ 14" Return 950 CFM 8" return 120 Smoke detector in return air drop 1.11.1111111i11111111 REFLECTED CEILING PLAN - MEZZANINE LEVEL 02 Scale: 3/16" =11-0" C:\Users\zadams\Documents1A15-280 Universal Building Systems CENTRAL ebrouillette.rvt 1000 CFM return . RTU-1 on roof 1st and 2nd level North of grid C 3/4" gas line up to RTU-1 with shut off valve and drip tee ceiling exhaust Type of 2 4" to 6" up to roof 6" 120 CFM 8" 200 CFM ...--111116011101 49'-0' AFF 18x18 supply and return up to RTU-1 14' supply and return down to lower level ACT 24 +10'4i'AFF. 8" 240CFM RTU-2 on roof lst and 2nd level Al South of grid C j �sr•Isrsd+lerl 3/4" gas line up to RTU-2 3/4" gas line up to RTU-2 with shut off valve and drip tee G. a +9'.O AFFa 12" 880 CFM return 6" exhaust up to roof cap 16x16 supply and return up to 14" 880 CFM return air CP-07 Existing 2Ib Gas meter space D-100 AL-425 MAOP 10 PSI ANSI Class 400 L Existing 1" gas vaive• a a Ems Existing gas unit heater 75,000 BTU a • a a eaaaary a a a Existing 1" gas line 2Lb New 1: gas line to RTU-1 and 2 EXP TO STftMGT ■■ter >•l�illw■■■■ 0- E =III ISM lilt. imo 8" 220 CFM Type of 2 G RTU-1 York 5 ton gas/electric Package Unit Cooling Performance Total capacity 59.8 MBH Sensible capacity 45.3 MBH Refrigerant type R-410A Seasonal Efficiency (at ARI) 13.00 SEER Efficiency (at ARI) 10.80 EER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 59.0 °F Leaving WB temp. 57.6 °F Power input (w/o blower) 4.54 kW Sound power 82 dB(A) Gas Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 100 MBH Supply air 2000 CFM Heating input capacity (Max) 125 MBH Leaving DB temp. 106.3 °F Air temp. rise 46.3 °F SSE 80.6 % Stages 1 Supply Air Blower Performance Supply air 2000 CFM Ext. static pressure 0.6 IWG Addl. Unit Losses (Options/Accessories) 0.15 IWG Blower speed 1103 RPM Duct location Bottom Motor rating 1.00 HP Actual required BHP 1.02 HP Power input 0.95 kW Elevation 0 ft. Drive type DIRECT Speed tap 5 Electrical Data Power supply 230-3-60 Unit min circuit ampacity 27.5 Amps Unit max over -current protection 35 Amps Dimensions& Weight Hgt 33 in. Len 83 in. Wth 45 in. Weight with factory installed options 644 lbs. Clearances Right 24 in. Front 32 in. Back 36 in. Top 72 in. Bottom 0 in. Left 36 in. RTU-2 York 4 ton gas/electric Package Unit Cooling Performance Total capacity 51.3 MBH Sensible capacity 39.5 MBH Refrigerant type R-410A Seasonal Efficiency (at ARi) 14.00 SEER Efficiency (at ARI)12.00 EER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp: 67.0 °F Leaving DB temp. 59.5 °F Leaving WB temp. 58.0 °F Power input (w/o blower) 3.51 kW Sound power 80 dB(A) Gas Heating Performance Entering DB temp. 60 °F Heating output capacity (Max)100 MBH Supply air 1786.2 CFM Heating input capacity (Max) 125 MBH Leaving DB temp. 111.8 °F Air temp. rise 51.8 °F SSE 80.6 % Stages 1 Supply Air Blower Performance Supply air 1786.2 CFM Ext. static pressure 0.58 IWG Addl. Unit Losses (Options/Accessories) 0.13 IWG Blower speed 1047 RPM Duct location Bottom Motor rating 1.00 HP Actual required BHP 0.82 HP Power input 0.76 kW Elevation 0 ft. Drive type DIRECT Speed tap 5 Electrical Data Power supply 230-3-60 Unit min circuit ampacity 27 Amps Unit max over -current protection 35 Amps Dimensions & Weight Hgt 33 in. Len 83 in. Wth 45 in. Weight with factory installed options 616 lbs. Clearances Right 24 in. Front 32 in. Back 36 in. Top 72 in. Bottom 0 in. Left 36 in. CORRECTION LTR#_ RECEIVED CITY OF TUKWILA DEC 18 2015 PERMIT CENTER MECHANICAL SCHEDULE . TAG MODEL CFM Gas input Economizer HP VOLTAGE AMPS RTU-1 York ZFO6ON10A2AAA4 2000 120,000 100% 1 208/3 35 amp RTU-2 York ZE048N10A2AAA4 1786 120,000 100% 1 •208/3 35amp EF-1&2 By owner 100 • 115/1 I L7I HL ALW VVtD: 41 1U.o UVvMT I b a a a a a a a a a a a a a e a a a. a e a a a a e a a e a a a ■ is a a a a a a s S a. a a a` a a a e a Ili nn S a a a r.I.1iIli Ile T a a a mew came face cause 41 Ufa MEW ewe zacata 42 ME gcm TM.: 425 827 2 E u a N W wow fl) F W a. UI is fa w z it■m S gil im CO UI 14600 INTERURBAN AVE. SOUTH REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 8 2016 Ci of Tukwila UIL/ISI SUBMITTAL r F 5 ta 15 M-3 Williams Mechanical 3903 Smith Ave Everett, WA 98201 I I I TI L :- yOF L CID1 4»_1'-0» 0" NEW HVAC UNIT it PLACE OPENING PER EXISTING STRUCTURAL ti JOISTS MECH UNIT BODY DAMPENING MATERIAL PER MANUF. FACTORY NAILER STRIP (2X) GALV. MTL FLASHING — TYP. ATTACH TO CURB AS REQ'D BY MANUF. GALV. MTL COUNTER FLASHING — TYP. FACTORY CURB ATTACH PER MANUFACTURER ROOFING MEMBRANE UP (Sc OVER CURB ATTACH ROOF'G TO NAILER AT TOP OF CURB 18" OC, MIN 2 PLACES EA. SIDE SEE STRUCT. FOR TYP. OPENING SUPPORT AND ROOF PENETRATIONS ROOF STRUCTURE ROOF BLOCKING EC CURB DET IL 1 "=1'-0" t i i i.a i fLA DEC 0,1 2015 PERMET CENTER REMARKS T.I. PERMIT SUBMITTAL DATE 06/08/15 O Z r WILLIAM : ` FULLER STATE OF WASHINGTON REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 8 2016 City of Tukwila BUILDING DIVISION -4 Williams Mechanical 3903 Smith Ave Everett,WA 98201