Loading...
HomeMy WebLinkAboutPermit D15-0016 - NORTHWEST MOUNTAIN MINORITY SUPPLIER - WALL, PAINT, CARPET AND CASEWORKNORTHWEST MOUNTAIN MINORITY SUPPLIERS 545 ANDOVER PARK W SUITE 109 D15-0016 City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 2623049144 Permit Number: D15-0016 Address: 545 ANDOVER PARK W 109 Issue Date: 2/17/2015 Permit Expires On: 8/16/2015 Project Name: NORTHWEST MOUNTAIN MINORITY SU Owner: Name: SOUTHCENTER CORPORATE SQUAR Address: 150 CALIFORNIA ST, SAN FRANCISCO, WA, 94111 Contact Person: Name: CHELSEA GASKILL Address: 635 ANDOVER PARK W STE 107, TUKWILA, WA, 98188 Contractor: Name: DAVIS SCHUELLER INC Address: 20700 44TH AVE W STE 280, LYNNWOOD, WA, 98036 License No: DAVISS1105PN Lender: Name: SOUTHCENTER CORPORATE SQUARE Address: 635 ANDOVER PARK W, TUKWILA, WA, 98188 DESCRIPTION OF WORK: Phone: (206) 575-3080 Phone: (206) 775-9400 Expiration Date: WALL DEMO AND CONSTRUCTION, PAINT, CARPET AND CASEWORK Project Valuation: $50,000.00 Fees Collected: $1,675.44 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Chan neIization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No �' YY// �/l,�, Permit Center Authorized Signature: ��'- Date: (7 S I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit an agree to the conditions attached to this permit. Signature: J--Date: 2 —17-L Print Name: (000Tr- This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 71 Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 30: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 13: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 17: Maintain fire extinguisher coverage throughout. 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 22: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 26: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 24: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 23: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 28: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 29: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 32: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at(206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0406 SUSPENDED CEILING r CITY OF TUKWILA •� Community Development Department Public Works Department �� • Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httv://www.TukwilaWA.gov Building Permit No. p i S— co/ 0 Project No. Date Application Accepted: Date Application Expires: Z'-a—tp 1 use CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: Site Address: 545 Andover Park West Suite Number: 109 Floor: 1 Tenant Name: Nothwest Mountain Minority Supplier New Tenant: 0 .....Yes ❑..No PROPERTY OWNER Name: Southcenter Corporate Square LLC Address: 635 Andover Park West Suite 107 City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Chelsea Gaskill Address: 635 Andover Park West Suite 107 City: Tukwila State: WA Zip: 98188 Phone: (206) 575-3080 Fax: Email: cgaskill@pinnaclefamily.com GENERAL CONTRACTOR INFORMATION Company Name: Davis Schueller Address: 20700 44th Ave S. Suite 280 City: Lynnwood State: WA Zip: 98036 Phone: (425) 775-9400 Fax: Contr Reg No.: DAVISSI105PN Exp Date: 07/15/2015 Tukwila Business License No.: BUS-0993315 ARCHITECT OF RECORD Company Name: Marvin Stein Architect Name: Jenni Keniston Address: 1500 Westlake Ave N. Suite One City: Seattle State: WA Zip: 98109 Phone: (206) 441-1449 Fax: Email: j.keniston@marvinstein.com ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Southcenter Corporate Square, LLC Address: 635 Andover Park West City: Tukwila State: WA Zip: 98188 H:\App1iL�tions\Forms-Applications On Line\2011 ApplicationsTcrutit Application Revised - 8-9-11.docx Revised: August 2011 bh Pagel of 4 BUILDING PERMIT INFORMATIOi. 2206431-3670 Valuation of Project (contractor's bid price): $ 50,000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Wall demo and construction, paint, carpet, casework. Will there be new rack storage? ❑..... Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below ::1 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I' Floor 9,611 2 Floor 10,734 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? El ....... Yes 0....... No FIRE PROTECTION/HAZARDOUS MATERIALS: Compact: Handicap: If "yes", explain: 0 ....... Sprinklers 0 ....... Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ....... Yes No If "yes, attach list of materials and storage locations on a separate 8-112" x 11 " paper including quantities and Material Safe , Data Sheets. SEPTIC SYSTEM ❑ ....... On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Fomis-Applications On Line\2011 ApplicationsTermit Application Revised - 8.9.11.docx Revised: August 2011 Page 2 of 4 bh PUBLIC WORKS PERMIT INFO>t MATION - 206433-0179 " Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District 0 ...Tukwila ❑ ... Water District #125 ❑ .. Highline ❑ .. Renton ❑ ...Water Availability Provided Sewer District 0 ...Tukwila ❑... Valley View ❑ .. Renton ❑ .. Seattle ❑ ...Sewer Use Certificate ❑... Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with ADDlication (mark boxes which aD [J.-Civil Plans (Maximum Paper Size — 22" x 34" ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond 0-Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ .. Right-of-way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right -of --way ❑ ❑ ...Total Cut cubic yards ❑ .. Work in Flood Zone ❑ ...Total Fill cubic yards ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped Fire Line ❑ .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection " Irrigation " Domestic Water " ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size.. WO # ❑ ...Water Only Meter Size............ WO # ❑ ...Deduct Water Meter Size " ❑ ...Sewer Main Extension.............Public ❑ Private ❑ ❑ ...Water Main Extension.............Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billinz Name: Day Telephone: Mailing Address: City State Zip HAApplicationsTo=-Applications On Line\2011 ApplicationsTennit Application Revised - 8-9-1 I.docx Revised: August 2011 Page 3 of 4 bh PERMIT APPLICATION NOTES - -� Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: r- (/l.f' - t S e q L-1t c- S k t i ii Date: i & t Day Telephone: 2 S1 7- 'P>610 Mailing Address: �0 357 p IL tdQtl' PA V F- �Li k- �i�i r- LL2� - qPl City State Zip to-7 H:\Applications\Fonns-Applications On Line\2011 Appin:ationsTermit Application Revised - 8-9-11.docx Revised: August 2011 Page 4 of 4 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,675.44 D15-0016 Address: 545 ANDOVER PARK W 109 Apn: 2623049144 $1,675.44 DEVELOPMENT $1,626.29 PERMIT FEE R000.322.100.00.00 0.00 $982.90 PLAN CHECK FEE R000.345.830.00.00 0.00 $638.89 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $49.15 TECHNOLOGY FEE TOTALi R000.322.900.04.00 0.00 $49.15 Date Paid: Monday, January 26, 2015 Paid By: SOUTHCENTER CORP SQUARE LLC Pay Method: CHECK 6198 Printed: Monday, January 26, 2015 11:22 AM 1 of 1 RWSYSTEMS W INSPECTION RECORD Retain a copy with permit 00 INSPECTION NO. PERM NO, CITY OF TUKWILA BUILDING 6300 $outhcenter Blvd,, #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 436-9350 DIVISION (206!! ) 431-3670 L NW A k ��k Type of Inspectio Address: ll ate faked: Special Instructions: i 6 Ct Date Wanted. a.m. -'� - 7--3 p.m. Requester'. 6-t-try 49 `os hone N ( ZeG-5-(O -6 Dq Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Catt to schedule reinspection. M INSPECTION RECORD ...... ..... Retain a copy with permit I-P15-- 00 (41 INSPECTION NO, PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 6 (L ?� Permit Inspection Request Line (206) 436-9350 —( KA k Project, a :No Atk qk 'P e _ Inspection: Ar. -�`l Ad re s: 4�- z L/er 7opk LJ_ ate Called. special Instructions: Date —Wanted- a.m. 3 - )�'3 - Lr p.m. RequiRter: Pgone No: UaTe: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cat[ to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS ION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd,, #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr ' c t . /V [d Af+u Type of inspectiow. --.- Address. s7m,tdo11 e-fl- atk, id, Date Called: Special Instructions: — lob Date wanted: a.m. 2,-7-7- 1 Y p.m. Req st r: e/ -P, Phone No: 0 - 6 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection, INSPECTION RECORD Dl S- 0o1 b Retain a copy with permit I S - S - INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project 0,c fliA) h' L'`GP 1� Type Inspection i r t t✓tA c� Address: Suite #: Contact Person: Special Instructions: Phone No.: E�jApproved per applicable codes. COMMENTS: t �A 1-- r OIL :A Corrections required prior to approval. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: % �� Date: Hrs.: ❑ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. tsming waaress Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 PERMIT C40RD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0016 DATE: 01/26/15 PROJECT NAME: NORTHWEST MOUNTAIN MINORITY SUPPLIER SITE ADDRESS: 545 ANDOVER PARK W - SUITE 109 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter #, DEPARTMENTS: &C) -�-►� Bundling Division to J 19 0 � -" Public Works PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: Revision # after Permit Issued Fire Prevention Structural ❑ CP ( qt� P21-l5 Planning Division a Permit Coordinator DATE: 01/27/15 Structural Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/24/15 Approved ❑ Approved with Conditions d Corrections Required ❑ (corrections entered in Reviews) Notation: R:EVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 Joanna Spencer From: Todd Reedy Sent: Thursday, January 29, 2015 6:57 AM To: Joanna Spencer Subject: RE: TI @ 545 APW D15-0016 Good morning Joanna, The only backflow deficiency at 545 Andover Park West is that there is a 1.5" RPPA internally in a mechanical room that isolates the tenant space for Hairclub for Men that did not get tested last year. The test due month for this property is May and the last test performed on that RPPA was May 2013. Other than that the premise isolation RPPA, fireline DCDA, and irrigation DCVA are all current. Let me know if you need any additional info, Todd From: Joanna Spencer Sent: Wednesday, January 28, 2015 8:55 AM To: Todd Reedy Cc: Han Kirkland Subject: TI @ 545 APW D15-0016 Good Morning Todd, Are their backflows current? Joanna ph:(206) 431-2440 fax:(206) 431-3665 Joanna.Spencer@TukwilaWA.gov The City of opportunity, the community of choice. DIGw- 0016 DAVIS SCHUELLER INC Page I of 2 Home Inicin en Espanol Contact Safety Cb Washington State Department of Labor & Industries DAVIS SCHUELLER INC Owner or tradesperson SCHUELLER, KENNETH E Principals SCHUELLER, KENNETH E, PRESIDENT STOCKBURGER, JAMES A, VICE PRESIDENT SCHUELLER, DANETTE, SECRETARY SCHUELLER, KENNETH E, TREASURER DAVIS, BILL E, PRESIDENT (End: 06/26/2014) SCHUELLER, KENNETH E, VICE PRESIDENT (End: 06/26/2014) DAVIS, BARBARA D, TREASURER (End: 06/26/2014) Doing business as DAVIS SCHUELLER INC Search L&I z] A-'L Index Help My Secure LRI Claims & Insurance Workplace Rights Trades & Licensing 20700 44TH AVE W STE 280 LYNNWOOD, WA 98036 425-775-9400 SNOHOMISH County WA UBI No. Business type 601 273 797 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ................ Meets current requirements. License specialties GENERAL License no. DAVISS1105PN Effective — expiration 10/1511990— 07/01/2016 Bond ............... CBIC $12,000.00 Bond account no. SF2518 Received by L&I Effective date 10/31/2003 10/15/2003 Expiration date Until Canceled Insurance ............................. . AMCO Ins Co $1,000,000.00 Policy no. ACP3006636708 https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601273797&LIC=DAVISSII05PN&SAW= 02/17/2015 ACOUSTICAL CEILING TILE JOINT ADJ ADJACENT / ADJUSTABLE LL@TE BY LANDLORD AT TENANT'S EXPENSE AFF ABOVE FINISH FLOOR LF LINEAL FOOT ALT ALTERNATE MAX MAXIMUM ALUM ALUMINUM MECH MECHANICAL APPROX APPROXIMATELY MFR MANUFACTURER @ AT MIN MINIMUM BLDG BUILDING MISC MISCELLANEOUS BLKG BLOCKING MTD MOUNTED B/S BUILDING STANDARD MTL METAL CAB CABINET MW MICROWAVE OVEN CLR CLEARICLEARANCE N NORTH/NEW CLG CEILING N/A NOT APPLICABLE CL CENTERLINE NIC NOT IN CONTRACT COL COLUMN NO NUMBER COMM COMMUNICATION NOM NOMINAL COMP COMPOSITION NTS NOT TO SCALE CONST CONSTRUCTION OC ON CENTER CONT CONTINUOUS OPNG OPENING CPT CARPET OPP OPPOSITE CT CERAMIC/CONCRETE TILE ORIG ORIGINAL DIA DIAMETER PERM PERMANENT DIM DIMENSION PL PLATE DR DOOR PLAM PLASTIC LAMINATE DW DISHWASHER PLYWD PLYWOOD DWG DRAWING PR PAIR E EXISTING / EAST PTN PARTITION EA_ EACH R RADIUS/REMOVE/RELOCATE ELEC ELECTRIC RB RUBBER BASE ELECT ELECTRICAL REF REFRIGERATOR ELEV ELEVATION (VIEW) REINF REINFORCING EXIST EXISTING REQ'D REQUIRED EXT EXTERIOR REV REVISION / REVERSE FIN FINISH RM ROOM FLR FLOOR RO ROUGH OPENING FLUOR FLUORESCENT S SOUTH FMC FLOOR MATERIAL CHANGE SCHED SCHEDULE FIR FIRE RATED SC SOLID CORE FT FEET SECT SECTION FURN FURNISH /FURNISHINGS SIM SIMILAR GA GAUGE SPEC SPECIFICATION GALV GALVANIZED SQ SQUARE GD GARBAGE DISPOSAL STD STANDARD GL GLASS / GLAZING STL STEEL GWB GYPSUM WALL BOARD STOR STORAGE HC HOLLOW CORE SUSP SUSPENDED HDW HARDWARE TEL TELEPHONE HM HOLLOW METAL TSG TEMPERED SAFETY GLASS HT HEIGHT TYP TYPICAL HVAC HEATING, VENTILATING., VCT VINYL COMPOSITION TILE AIR CONDITIONING VERT VERTICAL IN INCH W WEST INCL INCLUDE W/ WITH INSUL INSULATION W/o WITHOUT INT INTERIOR WC WALLCOVERING WD WOOD 2 I ABBREVIATIONS 1/4" NON-COMBUSTABLE WOOD FILLER UNDER MAIN RUNNERS. r rl CEILING HERE INDICATED ON N REFLECTED CEILING PLAN). CONTINUOUS'U METAL TRIM W/ PAPER WING (BOTH SIDES OF PARTITION) GALV. STEEL SILL TRACK. ATTACH TO STRUCTURE WITH HILTI X-U (OR XU15) UNIVERSAL KNURLED SHANK POWER DRIVEN FASTENER WITH MIN. 1" EMBEDMENT @ 16" O.C. (FOLLOW MANUFACTURER'S INSTRUCTIONS). FLOORING AS SCHEDULED (BOTH SIDES OF PARTITION) - STUD SCHEDULE: 2-1/2" = 250S125-27 (22 GA); MAX 10'-0" HIGH. 3-5/8" = 362S125-27 (22 GA); MAX 13'-0" HIGH. 6" = 60OS125-27 (22 GA); MAX 1T-6" HIGH. NOTES: 1. ALL STUDS ARE AT 16" O.C. 2. USE SAME GAUGE AS STUDS FOR TRACKS AND CHANNEL. 3. USE SSMA TECHNICAL GUIDES. EXISTING LOBBY AND CORRIDOR - NIC., TYP. CORE (SHADED AREA) - N.I.C., TYP. I I I I 01 o 014: -405 SCOPE OF WORK TENANT IMPROVEMENT TO AN EXISTING SUITE 109 AT THE SOUTHWEST CORNER OF THE 1ST FLOOR FOR OFFICE USE TO INCLUDE: ' • DEMOLITION OF PARTITIONS AND DOORS a STRAN ER BLVD. • CONSTRUCTION OF PARTITIONS AND DOORS w • CONSTRUCTION OF CASEWORK p • NEW PAINT AND FLOORING THROUGHOUT SUITE } z • NO STRUCTURAL WORK ST E • NO ALTERATIONS OF CORE. w AREA OF SUITE: 1,488 SQ.FT. z MINKLER LVD. v AREA OF FLOOR: 10,000 SQ. FT. _ UPLAND D . OCCUPANCY TYPE: B, OFFICP CO MIDLAND D Z. TRILAND D CONSTRUCTION TYPE: V-N, SPRINKLERED NORTH APPLICABLE CODES 2012 INTEROTIONAL BUILDING CODE (IBC) 2012 INTERNATIONAL FIRE CODE (IFC) 2012 INTERNATIONAL MECHANICAL CODE (IMC) 2012 NATIONAL ELECTRICAL CODE POINT WHERE 2 PATHS TO SEPARATE EXITS ICC/ANSI 117.1- ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES VICINITY ' ARE AVAILABLE. 1 V I C I N I 1 I/ MAP NTS 2012 WASHIN)S-7ON STATE ENERGY CODE (WSEC) 2012 INTERNATIONAL FUEL AND GAS CODE (IFGC) 2012 UNIFORt, PLUMBING CODE (UPC) TRAVEL DISTANCE. WASHINGT%i, INDOOR AIR QUALITY CODE MAXIMUM LENGTH ALLOWED IS 300' PER,IBC 4 TABLE 1016.2. 12 ASSESSOR'S PARCEL #: 262304-9144 10 BLDG 1 LEGAL DESCRIPTION 2 LOT 4 OF CITE"' OF TUKWILA SHORT PLAT NO L97-0049 RECORDING NO 9711069009 SAID SHORT PLAT DEFINED- PORTION OF E 1/2 OF NW 1/4 OF SE 114, BEGIN NE CORNER OF SAID E 1/2 BEING N 88-05-42 W 1339.34 FT Q FROM NE CORNER OF SE 1/4 TH S 0147-29 W 1322.34 FT TO SOUTHEAST CORNER TH N 87-55-02 W 659.34 FT OF SAID E 1/2 TH N 01-47-29 E 1320.20 FT TO N LINE OF SAID E 1/2 TH S 88-05-42 E 659.34 FT TO POB LESS PORTION FOR 59TH Y AVE SOUTH LESS PORTIONS FOR STREETS AS CONVEYED BY DEED, RECORDING NO 7907120770 LESS PORTION 8 5 Q CONVEYED TO CITY OF TUKWILA FOR ROAD BY DEED, RECORDING NO 9408290327. LLJ 1 7 6 O SOUTHCENTER CORPORATE z Q SQUARE - BUILDING 1 EXISTING 2-STORY OFFICE BUILDING NA 3 KEY PLAN, OCCUPANCY LOAD CALCULATIONS AND EXITING nAA NO CHANGE IN BUILDING AREA NO CORE / SHELL WORK NO STRUCTURAL WORK NO EXTERIOR WORK NO CHANGE IN USE O PROJECT DIRECTORY. e NORTH'S w ? NORTH TENANT COD ` MINKLER BLVD. WASHINGTON STATE RECYCLING ASSOCIATION F BUILDING REPRESENTATIVE PINNACLE FAMILY OF COMPANIES NA 4 SITE PLAN NTS 635 ANDOVER PARK WEST, SUITE:107 ' SEISMIC BRACING (BEYOND)'` , 0/TI 1. PER , "Fy : .' i , / 1 r ,cM , , 1 i 11 :O J K FTAPE, HOLD - h ' 1/8-BLAC FOAM AW BACK 14 FROM EDGE OF TRACK , t (BOTH SIDES) w ... , . MEN = , s- x r, c r t< METAL TRACK WITH 2 #10 x _ E < : {•. . ELEC. - 5 irb'f' vi } Pb ?A 2 -tf J f t i i , SCREWS AT 16"O.C. .. ,.:,, ,. _ ... :" < / C >:. ,.., M =,,, . kx - t... -„ J COMMON. UP -; s , , , i REVEAL PAINT BLACK OR MATCH EXISTING CONDITION. ,- BOTH SIDES OF PARTITION)'"Q x; :.. „ xr' . .-• " 3z ".may °_ . .` '; , . ' /,; /. 5/8 FIRE RETARDANT TREATED 4 ' PLYWOOD BLOCKING AT WALL / : HUNG ITEMS (WHERE a x ' ;' i APPLICABLE- REFER TO DRAWING PLANS). ' ALTERNATE FOR BLOCKING: l 20" WIDE SHEET METAL AT +40" EXIT FROM FLOOR TO BOTTOM (IN C a LIEU OF WOOD BLOCKING) k 40 I I MAIL ' KIN) € a I I 5 I i ELEC. OOM, R n r r 5/8 GWB TYPE X EACH SIDE ' a €I k - - / BASE, AS SCHEDULED. BOTH SIDES OF PARTITION. I i ( ) i k 4 8 F k e `L EXISTING STRUCTURE (BELOW) as 71 ji C 0 I I s ru I i - 9 , , 1 i . y , GALV STEEL STUD, PER STUD SCHEDULE, WITH 5/8" TYPE'X' GWB EACH SIDE.,11 1 5 I STANDARD TENANT PARTITION 191i'm TUKWILA, WA 98188 CONTACT: CHELSEA GASKILL TELEPHONE: (206) 575-3080 FAX: (206) 575-1198 EMAIL: CGASKILL@PINNACLEFAMILY.COM 4'-0" WIDE ACOUSTIC BATT INSULATION CENTERED OVER DESIGNER CONTRACTOR PARTITION ABOVE HUNG CEILING.1 -- , lT MARVIN STEIN AND ASSOCIAi ES, L"LC TBD Er --in SEISMIC BRACING (BEYOND) -a., 4 , ., ,. ; F. PER 101T1-1. 1500 WESTLAKE AVE. N, SUITE ONE 1/4" NON-COMBUSTABLE SEATTLE, WASHINGTON 98109 WOOD FILLER UNDER MAIN J F><t;rcanical COTACT: JENNI KENISTON ' , ` 1/8_ BLACK FOAM TAPE HOLD __ _ • RUNNERS. [t EiarCtnCal n BACK 1/4 FROM EDGE OF TRACK TELEPHONE. (206) 441-1449 CI Plumbing (BOTH SIDES) EMAIL: J.KENISTON@marvinstein.com [ Gas Piping n CEILING _8 8 A.F.F. _ WHERE INDICATED ON i ( METAL TRACK WITH 2 #10Tukwila () It of N C y REFLECTED CEILING PLAN). SCREWS AT 16" O.C. e . N P fi_1 31';l!G DIVISlO CONTINUOUS'L' METAL TRIM W/ PAPER WING BOTH REVEAL (PAINT BLACK) OR MATCH EXISTING CONDITION. SIDES OF PARTITION) (BOTH SIDES OF PARTITION) ACOUSTIC BATT INSULATION. MECHANICAL PLUMBING,RPROTECTION FI E 5/8" FIRE RETARDANT TREATED PLY WOOD BLOCKING AT WALL AND LIFE SAF ETY ETY N TE 0 S SOUTHCENTER CORPORATE SQUARE BUILDING 1 545 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 FILE COPY Permit o. V J n Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditi s is acknowledged: By: Date: 2- f 1- 2A l5 City of Tukwila BUILDING DIVISION REVISIONS No changes shall bo made to the scope of tvork writhout prior approval of Tulck.v la Building Division. NOTE-- I~-11ons will require a new plan submittal g I' and rna' indude add.t e r ^I plan c ud a 8 review .,s. P fees. j k HUNG ITEMS (WHERE APPLICABLE- REFER TO DRAWING PLANS). 1. MECHANICAL, FIRE PROTECTION AND LIFE SAFETY ALTERATIONS AND CONSTRUCTION ARE BY OTHERS, UNDER ALTERNATE FOR BLOCKING: SEPARATE PERMITS BY DESIGN BUILD CONTRACTORS - DEFERRED SUBMITTALS. GALV. STEEL SILL TRACK. 20" WIDE SHEET METAL AT +40" FROM FLOOR TO BOTTOM IN 2. REBALANCE THE HVAC SYSTEM AND PROVIDE WRITTEN REPORT TO OWNER AND/OR ARCHITECT. DRAWN BY: X ATTACH TO STRUCTURE WITH LIEU OF WOOD BLOCKING) HILTI X-U (OR XU15) UNIVERSAL 3. CLEAN ALL DIFFUSERS & GRILLS. CHECKED BY: LD KNURLED SHANK POWER DRIVEN n FASTENER WITH MIN.1 5/8" GWB, TYPE W EACH SIDE 4. - VERIFY LOCATION OF THERMOSTATS WITH OWNER OR ARCHITECT PRIOR TO FINAL INSTALLATION. EMBEDMENT @ 16" O.C. (FOLLOW MANUFACTURER'S 5. ALL CONSTRUCTIONORK IS,CO L OV DE BARRIERS W CONFINED TO THE BUILDING INTERIOR. CONTRACTOR SHALL PROVIDE 99135.102 INSTRUCTIONS). BASE, AS SCHEDULED. OR SYSTEMS TO CONTAIN DUST DIRT OR DEBRIS TO MINIMIZE INCONVENIENCE TO OTHER TENANTS WITHIN THE JOB NO.: (BOTH SIDES OF PARTITION.) BUILDING. FLOORING AS SCHEDULED BOTH SIDES OF PARTITION ( ) EXI TI S NG STRUCTURE BELOW ( ) 6. ON CONSTRUCTION OPERATIONS SHALL NOT OBSTRUCT HALLWAYS CORRIDORS STAIRWAYS OR MEANS OF > N0. REVISIONS INDICATED THUS 0 -DATE BY EGRESS FOR THE TENANTS OF THE BUILDING. PERMIT SET ISSUED FOR REVIEW 01 06 15 JK 7. DO NOT DISRUPT HVAC, PLUMBING, ELECTRICAL OR FIRE PROTECTION SYSTEMS WITHOUT PRIOR PERMIT SET 01 12 15 JK AUTHORIZATION FROM OWNER, 8. THE CONSTRUCTION SITE SHALL BE LEFT CLEAN & ORDERLY AT THE END OF EACH WORKDAY. STUD SCHEDULE 9. NO ONE WILL OCCUPY THE AREA OF WORK OTHER THAN AUTHORIZED CONSTRUCTION PERSONNEL. STUD SCHEDULE: 2-1/2" = 250S125-27 (22 GA); MAX 10'-0" HIGH. 3-5/8" = 362S125-27 (22 GA); MAX IT-0" HIGH. 6" = 60OS125-27 (22 GA); MAX IT-6" HIGH, NOTES: 1. ALL STUDS ARE AT 16" O.C. 2. USE SAME GAUGE AS STUDS V STEEL STUD, PER STUD IEDULE, WITH 5/8" TYPE'X' 3 EACH SIDE. NORTH FOR TRACKS AND CHANNEL. NOTE: MAINTAIN EXISTING ONE FOOTCANDLE PER SQUARE FOOT AT EGRESS PATHWAY LIGHTING. 3. USE SSMA TECHNICAL GUIDES. NEW OR RELOCATED B/S 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE EXISTING B/S 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE UPGRADED FOR UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY. EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY. 1-1/2" =1'-o, 6 EGRESS PLAN 1/8 1'-o,- 7 STANDARD TENANT SOUND PARTITION 1-1/2" = V-0 I 21/2" X 25 GA. STL. STUDS 5/8" GWB, TYPE X, TYP. STEEL TUBE BRACING - SEE ISOMETRIC BELOW PLAN 9" X 31/2" X 21/4" X 3116" METAL'L' EACH SIDE SECURED TO STEEL TUBE & ANCHORED x TO FLOOR AS REQUIRED (8'-0" O.C. MAX.) NOTE: k 3> 29 STEEL TUBE SUPPORT TO BE x MAX. HEIGHT FOR PARTITION x X _ x ISOMETRIC NA 9 PARTIAL HEIGHT PARTITION EXISTING STRUCTURE METAL CLIP METAL STUDS STAGGERED @ 8'-0" O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12'-0". ATTACH TO STRUCTURE ABOVE. (2) #10 SCREWS TI-1 COVER SHEET AND DETAILS TI-2 DEMOLITION PLAN AND CONSTRUCTION PLAN TI-3 REFLECT CEILING PLAN AND ELEC./COMMUNICATION PLAN TI-4 ENLARGED FLOOR PLAN, ELEVATIONS AND SECTIONS SCHEDULED CEILING TILE & GRID 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX 2' MAX NOTES: L, Ill TO END 1. LATERAL BRACING IS TO BE INSTALLED ON OF WALL TENANT PARTITIONS AT 8 FEET O.C. EXCEPT AT _z I INTERSECTIONS WITH WALLS AT LEAST 4 FEET FLONG. (PER TYPICAL PARTITION PLAN) OMIT BRACING AT WALL LATERAL BRACING (STAGGERED) PER TOP OF WALL 2• PROVIDE BRACING AT ANY PERMANENT DETAIL ABOVE (TYP.) PARTITION THAT IS NOT ATTACHED TO CEILING LATERAL WALL BRACING PLAN VIEW GRID. NTS 10 STANDARD HEAD B13 RACING NA 111 SHEET INDEX 10. THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY CONSTRUCTION BARRIERS TO INHIBIT ACCESS BY NON -AUTHORIZED PERSONNEL & AS REQUIRED BY O.S.H.A. STANDARDS TO PREVENT INJURIES OR ACCIDENTS. 11. N.F.P.A. / I.F.C. APPROVED FIRE EXTINGUISHERS SHALL BE LOCATED WITHIN 75 FEET FROM ANY POINT ALONG THE PATH OF TENANT EGRESS OR AS REQUIRED BY THE LOCAL FIRE MARSHAL. 12. THE SPACE AROUND PIPES DUCTS ETC. PENETRATING FIRE RESISTANT CONSTRUCTION SHALL NOT EXCEED'W & SHALL BE PACKED SOLID WITH APPROVED FIRE SAFING MATERIAL & SEALED WITH METAL ESCUTCHEONS EACH SIDE AS REQUIRED BY CODE. 13. MAINTAIN INTEGRITY OF RATED ASSEMBLIES AND REPAIR ANY DAMAGE TO SPRAY APPLIED FIRE PROOFING. ti RECEIVED CITY OF TUKWILA 0 JAN 2.6 '2015 GENERAL NOTES PERMIT CENTER 1. COMPLY WITH ALL APPLICABLE CODES. - TENANT: 2. THE GENERAL CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY THE FIELD CONDITIONS PRIOR TO NW MOUNTAIN MINORITY PURCHASING MATERIALS OR COMMENCING THE WORK. 3. REPORT ANY DISCREPANC'ES BETWEEN ACTUAL FIELD CONDITIONS AND DRAWINGS TO ARCHITECT BEFORE SUPPLIER DEVELOPMENT COUNCIL PROCEEDING WITH THE WORK. 4. VERIFY THE BUILDING STANDARDS (B/S) BEFORE PROCEEDING WITH THE WORK. 5. OBTAIN ALL REQUIRED PERMITS AND APPROVALS BEFORE PROCEEDING WITH THE WORK. (SUITE 109 ) 6. WALLS, PARTITIONS AND CEILINGS SHALL BE INDEPENDENTLY BRACED TO RESIST SEISMIC FORCES. 7. PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS. 8. ALIGN AND SHIM TRANSITIONS BETWEEN OLD AND NEW CONDITIONS. SHEET TITLE: 9. LEVEL THE FLOOR. DEVIATIONS OF ± 1/2"WITHIN 10'-0" IS THE ACCEPTABLE LIMIT, 10. GENERAL CONTRACTOR REVIEW AND STAMP OR MARK REQUIRED SUBMITTALS AND SHOP DRAWINGS PRIOR TO SENDING COPIES TO MSA FOR REVIEW AND COMMENT. COVER SHEET & DETAILS 11. THE BUILDING OWNER OR THE OWNER'S AUTHORIZED REPRESENTATIVE SHALL ESTABLISH WORKING TIME AND STANDARDS OF CONDUCT. 12. DO NOT SCALE DRAWINGS, 13. THE GENERAL CONTRACTOR SHALL COORDINATE THE ACTIVITIES OF ALL SUBCONTRACTORS, DELIVERY, AND 00 THE STAGING OF MATERIALS. 14. GENERAL CONTRACTOR SHALL NOT START CASEWORK UNTIL CONFERENCE / COPY / BREAK / WORK ROOM REPRODUCTION, ALTERATION OR PUBLICATION OF THIS CASEWORK SHOP DRAWINGS HAVE BEEN REVIEWED BY MSA. DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A T1.1 VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2015. OF - 4 SOUTHCENTER D E Q DEMOLITION PLAN 1 /8" =1'-0" 0 5' 10' 20' 30, NORTH DEMOLITION LEGEND DEMOLITION NOTES EXISTING BUILDING CORE TO REMAIN. EXISTING CONSTRUCTION TO REMAIN. EXISTING CONSTRUCTION TO BE DEMOLISHED. DEMOLITION KEYNOTES OREMOVE EXISTING ELECTRICAL OUTLETS AND PLUMBING ALONG THIS SECTION OF WALL, PATCH AND PREP PARTITION TO RECEIVE NEW PAINT. REMOVE EXISTING REMAINING DRYING MACHINE EXHAUST EQUIPMENT. REPAIR EXISTING CEILING TILES ARE REQUIRED. OREMOVE EXISTING SERVER EQUIPMENT AND WIRING FROM SERVER CLOSET. EXISTING WALL MOUNTED FIRE TREATED PHONE BOARD TO REMAIN. COORDINATE WITH TENANT. 1. A CLEAR PATH OF EGRESS TRAVEL SHALL REMAIN OPEN AT ALL TIMES DURING DEMOLITION. 2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES AND THE BUILDING MANAGEMENT. 3. ALL DEBRIS SHALL BE REMOVED FROM THE CONSTRUCTION SITE DAILY. 4. ALL DEMOLITION SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING MANAGEMENTS RULES AND REGULATIONS WITH MINIMAL DISTURBANCE TO OTHER TENANTS. 5. THE CONTRACTOR SHALL PROVIDE DUST BARRIERS FOR PROTECTION OF EXISTING ADJACENT AREAS. ALL HVAC SYSTEMS ARE TO BE PROTECTED DURING DEMOLITION. 6. THE CONTRACTOR SHALL NOTIFY THE OWNER AND MSA OF ANY DEMOLITION WORK THAT IMPACTS THE STRUCTURAL INTEGRITY OF THE BUILDING. 7. THE GENERAL CONTRACTOR SHALL IMMEDIATELY REPORT ALL ACCIDENTS, ERRORS OR DEFECTS TO THE BUILDING MANAGEMENT. CORPORATE SQUARE BUILDING 1 545 ANDOVER PARK WEST 11 10 9 8 TUKWILA, WASHINGTON 98188 (DCONSTRUCTION PLAN 1 /8" =1'-0" 0 5' 10' 20' 30' NORTH CONSTRUCTION LEGEND EXISTING BUILDING CORE. EXISTING CORRIDOR PARTITION. EXISTING DEMISING PARTITION. ZZZZ22= NEW B/S TENANT INTERIOR PARTITION. SEE DETAIL 51TI-1. NEW B/S SOUND PARTITION. SEE DETAIL 71TI-1. = = NEW B/S 3'-0" WIDE FULL -HEIGHT TEMPERED SAFETY GLASS RELITE. -- CWL NEW COLD WATER LINE. ALIGN. CONSTRUCTION NOTES 1. MAINTAIN A CLEAR PATH OF TRAVEL AT ALL TIMES DURING CONSTRUCTION. 2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & THE BUILDING OWNER / MANAGEMENT AND TENANT. 3. INSTALL DOUBLE STUDS AT DOOR JAMBS AND HEADERS. 4. PROVIDE FIBER GLASS REINFORCED WATER RESISTANT GYPSUM BOARD IN AREAS SUSCEPTIBLE TO MOISTURE. 5. DIMENSIONS ARE FINISH SURFACE TO FINISH SURFACE, U.N.O. 6. REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS TO THE ARCHITECT. 7. ALL EXISTING WINDOW COVERINGS TO BE CLEANED AND IN GOOD WORKING ORDER. CONSTRUCTION KEYNOTES 1O COORDINATE -WITH TENANT TO VERIFY THAT EXISTING WALL MOUNTED FIRE TREATED PHONE BOARD MEETS TENANT'S REQUIREMENTS. PAINT PHONE BOARD TO MATCH NEW GENERAL WALL COLOR. OREPAIR AND REPAINT EXISTING SUITE ENTRY DOOR AS REQUIRED TO BRING TO LIKE NEW CONDITION. DOOR SCHEDULE TYPE OF DOOR A. NEW B/S T-0" WIDE X T-0" HIGH X 1-3/4" THICK PAINT GRADE HOLLOW METAL DOOR IN B/S METAL FRAME TO MATCH EXISTING. OTHERWISE HARDWARE NOTED a. B/S LATCHSET. E EXISTING DOOR TO REMAIN NOTES: 1. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO BE LEVER -TYPE. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE FLOOR. 2. THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N), SLIDING OR FOLDING DOOR =15.0 POUNDS (67 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. 3. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.5 INCH (12.7 MM) IN HEIGHT. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 0.25 INCH (6.4 MM) AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL (50-PERCENT SLOPE). 4. EXIT DOORS MUST REMAIN UNLOCKED AT ALL TIMES IN THE DIRECTION OF EGRESS. PASSAGE EXIT HARDWARE SHALL REQUIRE NO SPECIAL KNOWLEDGE OR ASSISTANCE TO OPEN OR TO ACCESS. RECEIVED. CITY OF TUKWILA JAN 2 6' 2015 PERMIT CENTER DRAWN BY: JK CHECKED BY. LD JOB NO.: 99135.102 NO. REVISIONS INDICATED THUS DATE BY PERMIT SET ISSUED FOR REVIEW 01 06 15 JK PERMIT SET 01 /12/15 JK TENANT. NW MOUNTAIN MINORITY SUPPLIER DEVELOPMENT COUNCIL (SUITE 109) SHEET TITLE: DEMOLITION PLAN AND CONSTRUCTION PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A TI-2 VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2015. OF 4 DREFLECTED CEILING PLAN 1118" =1'-0" 0 5' 10' 20' 30, NORTH CEILING LEGEND EXISTING CEILING GRID AND TILES TO REMAIN. ❑ EXISTING 2'X2' AND 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO REMAIN. - -'-- EXISTING 2'X2' AND 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE L_J L---- J REMOVED/RELOCATED. NEW OR RELOCATED B/S 2'X2' AND 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES. NEW OR RELOCATED B/S 2'X2' AND 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY. ® B/S ILLUMINATED EXIT SIGN (DIRECTIONAL WHERE SHOWN). O N B/S LIGHT SWITCH. (M = SUITE MASTER, N = NEW) LIGHTING CALCULATION EXISTING CEILING GRID, TILE AND FIXTURES TO REMAIN. EXISTING LIGHTING LAYOUT USES (19) FIXTURES. THE NEW LAYOUT RELOCATES (11) OF THE EXISTING FIXTURES. 11/19 x 100 = 57.89% WHICH IS LESS THAN THE 60% ALLOWABLE CHANGE PER 2012 WSEC LIGHTING ALTERATION EXCEPTION C101.4.3.1. EXISTING WATTAGE STAYS THE SAME. CEILING NOTES 1. CHECK FOR CONFLICTS BEFORE INSTALLING OR RELOCATING LIGHT FIXTURES. NOTIFY MSA OF ANY CONFLICT(S). 2. REPLACE DAMAGED CEILING TILES AND GRID AS NECESSARY TO BRING CEILING TO "LIKE NEW" CONDITION. 3. MAINTAIN EXISTING ONE FOOTCANDLE PER SQUARE FOOT AT EGRESS PATHWAY LIGHTING. 4. MAINTAIN 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF ANY V.A.V. BOXES. 5. DAYLIGHT ZONE CONTROL: DAY LIGHTING AS DEFINED BY CODE SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS PER SECTION 1513.3 OF THE WASHINGTON STATE ENERGY CODE. 6. FIRE SPRINKLERS BY OTHERS UNDER DEFERRED SUBMITTALS. 7. COMMISSIONING REQUIREMENTS: TEST LIGHTING CONTROLS TO ENSURE THAT THE SYSTEMS COMPLY WITH CODES. PROVIDE A WRITTEN REPORT OF TEST PROCEDURES AND RESULTS TO THE OWNER. SWEEP CONTROLLERS ARE NOT BUILDING STANDARD, USE OCCUPANCY SENSORS AS REQUIRED. 8. EXIT SIGNS ARE INDICATED ON THE REFLECTED CEILING PLAN. THEIR PLACEMENT IS BASED UPON EXISTING CONDITION SURVEY. FINAL NUMBER OF SIGNS, THEIR PLACEMENT AND ARROW DIRECTIONS SHALL BE FIELD VERIFIED WITH THE BUILDING OFFICIAL, CONTRACTOR AND ARCHITECT. ELEC./COMMUNICATION PLAN 1/8" = 1'-0" 4& 0 5' 10' 20' 30' NORTH ELEC / COMMUNICATIONS LEGEND B/S WALL MOUNTED DUPLEX ELECTRICAL OUTLET. j (T) B/S WALL MOUNTED DEDICATED 120V 20A DUPLEX ELECTRICAL OUTLET. (T = TIMER) B/S WALL MOUNTED FOURPLEX ELECTRICAL OUTLET. B/S WALL MOUNTED COMBINATION VOICE/DATA OUTLET. ® POWER POLE. COORDINATE LOCATION WITH TENANT AND FURNITURE VENDOR. 'N' NEW. 'U' UPGRADE EXISTING. ELEC. / COMMUNICATION NOTES 1.. ALL ELECTRICAL OUTLETS TO BE MOUNTED AT 15" A.F.F. (AT BASE OF OUTLET) PER W.S.B.C. REQUIREMENTS U.N.O. 2. ROUGH IN ALL DATA AND COMMUNICATION LINES - MUD RING WITH PULL STRING, U.N.O. 3. PROVIDE NEW COVER PLATES AND RECEPTACLES AS NEEDED TO MATCH BUILDING STANDARD. 4. MAINTAIN EXISTING ELECTRICAL OUTLETS UNLESS LOCATION CONFLICTS WITH NEW CONSTRUCTION. 5. THE CONTRACTOR SHALL COORDINATE ELECTRICAL, LIGHTING, CASEWORK AND FURNITURE. ELEC / COMMUNICATIONS KEYNOTES 1O COORDINATE WITH TENANT TO VERIFY ELECTRICAL AND DATA REQUIREMENTS FOR SERVER ROOM. OPROVIDE OUTLET ACCESSIBLE FROM WITHIN MICROWAVE SHELF. SEE ELEVATION 2/TI-4. RECEIVED CITY OF TIJKWILA JAN 2 6 2015 PERMIT CENTER bit, - OCA4 SOUTHCENTER CORPORATE SQ BUILDING 1 545 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 1500 WESTLAKE "I N, SUITE ONE, SEATTLE WA, 98109 (206) 441-1449 DRAWN BY: X CHECKED BY: LD JOB NO.: 99135.102 NO. REVISIONS INDICATED THUS 0 DATE BY PERMIT SET ISSUED FOR REVIEW 01 06 15 X PERMIT SET 01 12 15 X TENANT. NW MOUNTAIN MINORITY SUPPLIER DEVELOPMENT COUNCIL (SUITE 109) SHEET TITLE: REFLECTED CEILING PLAN AND ELEC./COMMUNICATION PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2015. TI-3 OF 4 NOTES:SOUTHCENTER P. TI-4 1. PROVIDE FINISHED ENDS ON ALL EXPOSED SURFACES, TYP. 2. PROVIDE FILLER PANELS AS NECESSARY, TYP. co R P 0 RAT E SQ UARE B/S UPPER CABINET WITH DOORS AND 2 ADJUSTABLE SHELVES. BPLASTIC LAMINATE BUILDING 1 B/S MICROWAVE SHELF. TRANSACTION COUNTER. I PLAM TRANSACTI N COUNTER. B/S PLAM COUNTER TOP 36" B/S PLAM WORK S JRE. SCRIBE TO PARTIAL HEIG T PARTITION. 12 1-1/2" TI-4 545 AND 0 VE R PARK WEST = TY x AND BACKSPLASH. 1" 1" TUKWILA WASHINGTON 98188 — I X 3B B/S A.N.S.I: APPROVED PLAM SINK CABINET (NO BOTTOM @ N PARTIAL HEIGHT PARTITION WITH PAINT FINISH. PARTIAL HEIGHT A TITION WITH PAINT FINIS . " to BASE) WITH A.N.S.L- COMPLIANT - ) — — — — / SINK &FAUCET. M I I B/S LOWER CABINETS WITH ' 36" MAX DIM. TYP. DRAWERS, DOORS AND BASE, AS SCHEDULED. --- ADJUSTABLE SHELF. I 36" CLEARj 38" ENLARGED FLOOR PLAN 1/41'=1 -0° 2 ELEVATI0 1 3/s„ =1 -0 3 ELEVATIONS 3/s° =1 -o° 4 ELEVATION 3/8"=11-011 25" MIN. DIM. 12" (INSIDE CLEAR) PLAM COUNTERTOP AND 3/4" BACKSPLAS H. PL-1 DRAWER ON (75) POUND FULL- EXTENSION SLIDE. 1/4" PLYWOOD BACKING WITH MELAMINE ° E# (2) B/S CONCEALED HINGES PER DOOR. FINISH 1/4" PLYWOOD BACKING WITH MELAMINE ° ° ;l B/SRDA-COMPLIANT CASEWORK HARDWARE, TYP. ° MELAMINE INTERIOR. FINISH. SHELF SUPPORT, TYP. MELAMINE INTERIOR AS SCHEDULED ° ; (2) CONCEALED HINGES PER DOOR. ° 3/4" PLYWOOD ADJUSTABLE SHELF WITH 25" 12" o a 11 ° ° FINISH MELAMINE FINISH. 24" > w ° 3/4 PLYWOOD ADJUSTABLE SHELF WITH FINISH w J w ;; i' ADJUSTABLE SHELF WITH MELAMINE FINISH. ° ° B/S ANSI -COMPLIANT CASEWORK EQ. EQ. w o ° MELAMINE FINISH. w _ ___ ____— - ____ I '( HARDWARE. w a o ° i MELAMINE INTERIOR. °- o ° ,, j CABINET DOORS. P-LAM FINISH ON EXPOSED FACE WITH MATCHING EDGE - i CABINET DOORS. P-LAM FINISH ON PL-2 _ B/S S.S. FAUCET & PER ANSI 117.1 PLASTIC LAMINATE PL-3 WRAP PLAM FINISH [ CABINET DOORS. P-LAM FINISH ON EXPOSED ;! j BANDING AND MELAMINE FINISH ON INTERIOR FACE. EXPOSED FACE WITH MATCHING B/S EDGE BANDING AND MELAMINE FINISH 3/4" PLAM PL-1 SINK CODE COMPLIANCE COUNTER BEYOND I ON ALL EXPOSED TRANSACTION ° ° FACE WITH MATCHING B/S EDGE BANDING AND a ° I; PL-2 ! ON INTERIOR FACE. DOOR. BACKSPLASH- B/S PLAM PL-1 1 24. 4 " " COUNTER SURFACES. PL-3 ° MELAMINE FINISH ON INTERIOR FACE. ' 1/4" PLYWOOD BACKING WITH MELAMINE (2) B/S CONCEALED HINGES PER SPACE FOR MICROWAVE, TYP. COUNTERTOP, PER , B/S ADA-COMPLIANT CASEWORK HARDWARE. _ FINISH. PLAM BACKSIDE SPLASH. PL-2 SCHEDULE. / - BASE AS SCHEDULED. - - -- - -' - - - --- PROTECTIVE__71 j ( 18" 3/4" FIXED PLAM SHELF WITH MATCHING COVERING AT - EXPOSED _ B/S ADA- COMPLIANT CASEWORK _ WORK COUNTER WITH PL-2 MIN. DIM. 3 " ` B/S BANDING. PL-2 O PIPES. II HARDWARE 1 SELF -EDGED PLAM. `- '- SHIM AS '. REQUIRED. -0.7 24" 7 SECTION 1' = 1 - „ 1l4 PLYWOOD I= ' PROVIDE BLOCKING AS 5 _ SECTION 1-1/2 -1 '0 6 _ SECTION 1-1/2 -1-0 BACKING WITH ;' (2) CONCEALED HINGES PER PROVIDE GROMMET. j COORDINATE WITH TENANT. REQUIRED. MELAMINE FINISH. j EACH DOOR. I :: i CABINET DOORS. j SUPPORT BRACKET BEYOND. ( • DASHED (j P-LAM FINISH ON j ! PARTIAL HEIGHT LINES M EXPOSED FACE 1 PARTITION WITH INDICATE 6"MIN. CLR. REQUIRED 8"MIN. CLR. I WITH MATCHING I EDGE BANDING _ _ , j . PAINT FINISH AS SCHEDULED. SEE ACCESSIBLE AND MELAMINE N N i \`; DETAIL 91TI-1 FOR CLEARANCES. — FINISH ON PARTIAL HEIGHT li INTERIOR FACE. PARTITION. PL-2 :. CONTINUE FINISH FLOOR BELOW SINK - SCHEDULED RESILIENT jj a' BASE. BASE, PER S. SCHEDULE. ATTACH BASE TO DOOR. CUT BASE SHORT FOR PROPER DOOR OPERATION. 1500 WBSTLAKE AVE K SUITE ONE, SEATTLE WA, 99109 (206) 441-1449 8 NA NA 9 NA NA 10 NA NA 11 SECTION 12 SECTION 1-1/2„-1,_0„ DRAWN BY: JK w CHECKED BY: LD Go JOB NO.: 99135.102 W p v e 0 3 F NO. REVISIONS INDICATED THUS DATE BY PERMIT SET ISSUED FOR REVIEW 01 06 15 JK PERMIT SET 01 12 15 JK lm % s - G I 13 NA NA 14 i NA NA 15 NA NA 16 NA NA 17 NA NA TENANT: NW MOUNTAIN MINORITY SUPPLIER DEVELOPMENT SUPP 0 COUNCIL (SUITE 109) SHEET TITLE: i ENLARGED FLOOR PLAN, RECEIVED CITY of TU WILA ELEVATIONS AND JAN 2 6 2015 PERMIT CENTER SECTIONS REPRODUCTION, ALTERA11ON OR PUBLICATION OF THIS DRAWING WITHOUT EXPRESSED PERMISSION BY MSA IS A TI-4 18 NA NA 19 NA NA 20 NA NA 21 NA NA 22 NA NA VIOLATION MSA 2015.0E FEDERAL COPYRIGHT LAW. COPYRIGHT BY OF 4