Loading...
HomeMy WebLinkAboutPermit D15-0025 - POP GOURMET POPCORN - STORAGE RACKSPOP GOURMET POPCORN 13400 INTERURBAN AVE S D15-0025 Parcel No Address: Citv of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0003000115 Permit Number: D15-0025 13400 INTERURBAN AVE S Issue Date: 7/30/2015 Permit Expires On: 1/26/2016 Project Name: POP GOURMET POPCORN Owner: Name: HIC I LLC Address: PO BOX 700, MERCER ISLAND, WA, 98040 Contact Person: Name: LISA LYNN Phone: (253) 508-0236 Address: 500 SW 16 ST, RENTON, WA, 98057 Contractor: Name: MR RACKS LLC Phone: (425) 207-0058 Address: 500 SW 16TH ST, RENTON, WA, 98055 License No: MRRACRL924BN Expiration Date: Lender: Name: N/A LESS THAN $5,000 Address: , "I DESCRIPTION OF WORK: INSTALLATION AND ANCHORING OF 17 BAYS OF STORAGE RACKING Project Valuation: $2,500.00 Fees Collected: $257.98 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Occupancy per IBC: F-1 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Volumes: Cut: 0 Fill: 0 Number: 0 Water Meter: No Permit Center Authorized Signature: J. L� Date: 3U lS v I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local la regu ting construction or the performance of work. I am authorized to sign and obtain this developmenyf ermit AdafrSR a-ttie co/fditions attached to this permit. Signature: Print Nar> Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 9: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 10: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Maintain fire extinguisher coverage throughout. 13: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 12: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 14: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 15: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 16: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13-16.1.4) 17: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 18: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUKW., . Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 ri) Tukwila, WA 98188 htlli,,/J*wy Tykwfl WA,gs�v Building Permit No. Project No. Date Application Accepted:��1 Date Application Expires: � r- 7 use CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 0003000115 Site Address: 13400 INTERURBAN AVE S Suite Number: Floor: I Tenant Name: POP! GOURMET POPCORN New Tenant: ❑ .....Yes ❑ ..No PROPERTY OWNER Name: HRP PROPERTIES Address: P.O. BOX 700 ty: MERCER ISLAND State: WA Z'p 98040 CONTACT PERSON — person receiving all project communication Name: JOSHUA FRY Address: 500 SW 16TH ST City: RENTON State: WA Zip: 98057 Phone: (253) 508-0236 Fax: Email: GENERAL CONTRACTOR INFORMATION Company Name: MR. RACKS, LLC. Address: 500 SW 16TH ST City: RENTON State: WA Zip: 98057 Phone: (425) 207-0058 Fax: (425) 207-5016 Contr Reg No.: MRRACRL924BN Exp Date: 01/17/2016 Tukwila Business License No.: ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: SEIZMIC INC. Engineer Name: SAL FATEEN Address: 161 ATLANTIC STREET C'Ty' POMONA State: CA Zip: 91768 Phone: (909) 869-0989 Fax: (909) 869-0981 Email: OPERATIONS @SEIZMICINC. COM LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: H:\Applications\Forms-Applications On Line\2011 ApplicationsTertnit Application Revised - 8-9-1l.docx Revised: August 2011 bb Page 1 of 4 BUILDING PERMIT INFORMATIOP 96-431-3670 Valuation of Project (contractor's bid price): $ 2,500 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): 4STALLATION AND ANCHORING OF 17 BAYS OF STORAGE RACKING. Will there be new rack storage? ®.....Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I' Floor 2 nd Floor 3`d Floor Floors thru Basement Accessory Structure* `tached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard:_ Compact: Handicap: Will there be a change in use? El ....... Yes Z....... No If "yes,", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: m ....... Sprinklers ❑ ....... Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? El ....... Yes 91 .......No If "yes, attach list of materials and storage locations on a separate 8-112" x 11 " paper including quantities and Material Safety Data Sheets. :PTIC SYSTEM ❑ ....... On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line\2011 ApplicationAPermit Application Revised - 8-9-1 I.docz Revised: August 2011 Page 2 of 4 bh PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. ,piration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Print Name Joshua C. Fryy Mailing Address: 500 SW 16TH ST Date: 01 /26/2015 Day Telephone: (253) 508-0236 RENTON WA 98057 City State Zip H:\Applications\Forms-Applications On Line\2011 ApplicationsTermit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Date Paid: Monday, February 02, 2015 Paid By: MR RACKS Pay Method: CHECK 4703 Printed: Monday, February 02, 2015 3:12 PM 1 of 1 RWSY57EM5 DESCRIPTIONS PermitTRAK ACCOUNT $161.06 D15-0025 Address: 13400 INTERURBAN AVE S Apn: 0003000115 $161.06 DEVELOPMENT $153.60 PERMIT FEE 11000322.100.00.00 0.00 $149.10 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $7.46 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: •. 1 13000.322.900.04.00 0.00 $7.46 Date Paid: Thursday, July 30, 2015 Paid By: MR. RACKS Pay Method: CHECK 5145 Printed: Thursday, July 30, 2015 4:40 PM 1 of 1 RWSYS7EMS (2J--) INSPECTION RECORD Retain a copy with permit _ INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect: / �� (:3� Type����ecti�, e- A dr ss: p��� �" i Date Calle . f0', Special Instructions: Date Wanted: #- a.m. a— 2i — rJ p.m. Reque, Phone No: Inspector: Date REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit '115PECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ?f,p Got,aAj ?dPCW-(`) Type of Inspection: r-I K* 1 Address: 1w� - ,-bay �vL Date C Iled: SpeciakInstructions: Date Wants : a.m. ?—//-/5 p.m. Requester: Phone No: Inspector: Date: El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I' f JCILIVIII.. 1 f `�� F INC.rIL l ALXTER��LHAN LrN-_ LNrkRL\G EST.1n8v SPEC14L PROD V CTS CONFEFORS STOR4GEPUCKS 0TIERSERVICES SHELVING SPECIALSPRODUCIS TANK SUPPORTS TALL SUPPORTS SELECTIVE SEISMICAiNALYSIS METAL SHUTTLES ALACHLNFRY HEADER STEEL DRIVE-IN PERTBT ACQUISITION METAL/WOOD RACK BLDGS SORT PLATFORM PUSH BACK EGRESS PLANS MOVABLE CAROUSELS SHEDS PICK MODULES FLOWR4CK SFATEAPPROVALS GONDOLAS VRC MEZZANENES ROOF VERIFICATION CANIILEVER PRODUCTTESTING LOCKERS A10DULAROFFICES FOOTA'GS CATIM41l:S FENCES Licensed in all 50 States rREND FOROMPLIANCEROVED 9 2015 City of Tukwila ING DIVISION SEISMIC ANALYSIS OF STORAGEAC RKS FOR POP GOURMET POPCORN 13400 INTERURBAN AVENUE SOUTH TUKWILA, WA 98168 Job No. 15-0101 SAL E i1, P. `0 1 � ,i 1 RECEIVED CITY OF TUKWILA FEB 0 2 2015 PERMIT CENTER 161 ATLANTIC STREET POMONA * CA 91768 * TEL: (909) 869-0989 FAX: (909) 869-0981 SE SErzn��c ^; { MATE I�NDLI14G, ENGINEERING fEf : '•(J09)} 69 - 0989-TAX: (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT POP GOURMET POPCORN FOR MR. RACKS LLC, SHEET NO. 2 CALCULATED BY TC DATE 1/23/2015 TABLE OF CONTENTS TABLE OF CONTENTS & SCOPE PR14MET'ERS �- -- - ;,�iAl'i"C-614ONENTS & SPECIFICATIONS LOADS,& DISTRIBUTION LONGITUDINAL ANALYSIS COLUMN BEAM TO COLUMN BRACING ANCHOR ANALYSIS BASIC LOAD COMBINATIONS !1[ TOT) TT TT7ATTlkTf� 3 4 5 6 7 8 12 13 14-16 17 18 19 20 SCOPE: THIS ANALYSIS OF THE STORAGE SYSTEM IS TO DETERMINE ITS COMPLIANCE WITH THE APPROPRIATE BUILDING CODES WITH RESPECT TO STATIC AND SEISMIC FORCES. THE STORAGE RACKS ARE PREFABRICATED AND ARE TO BE FIELD ASSEMBLED ONLY, WITHOUT ANY FIELD WELDING. ESEEMIC MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT POP GOURMET POPCORN FOR MR. RACKS LLC. SHEET NO. 3 CALCIJLATED BY TC DATE 1 /23/2015 THE STORAGE RACKS CONSIST OF SEVERAL BAYS, INTERCONNECTED IN ONE OR BOTH DIRECTIONS, WITH THE COLUMNS OF THE VERTICAL FRAMES BEING COMMON BETWEEN AND ADJACENT BAYS. THE ANALYSIS WILL FOCUS ON A TRIBUTARY BAY TO BE ANALYSED IN BOTH THE LONGITUDINAL AND TRANSVERSE DIRECTION. STABILITY IN THE LONGITUDINAL DIRECTION IS MAINTAINED BY THE BEAM TO COLUMN MOMENT RESISTING CONNECTIONS, WHILE BRACING ACTS IN THE TRANSVERSE DIRECTION. CONCEPTUAL DRAWING Some components may not be used or may vary. 1. COLUMN 2. BASE PLATE 3. ANCHORS 4. BRACING 5. BEAM 6.CONNECTOR TIsI@UT'6pw 'ErA f i 10. LONGITUDINAL NOTE: ACTUAL CONFIGURATION SHOWN ON COMPONENTS & SPECIFICATIONS SHEET SE115 ZMIC�' MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROTECT POP GOURMET POPCORN FOR MR. RACKS LLC. SHEET NO. 4 CALCULATED BY TC DATE 1/23/2015 COMPONENTS & SPECIFICATIONS : TYPE 48x96 SITE CLASS = D ANALYSIS PER SECTION 2209 OF THE 2012 IBC Beam Elevation ProductLoad/Lel Panel Heights LEVELS = 2 HI = 72 in. H2 = 72 in. W1=2500lbs. Yl = 22 in. TY4 W2 =2500 lbs. Y6 Y2 = 22 in. Y- = 22 in. PANELS = 6 = 22 in. PRODUCT LOAD / L %, L = 2500 lbs. H2 Y5 Y5 = 22 in. Y6 = 22 in. FRAME HEIGHT = 144 in. Y4 H bl 1 F I FRAME DEPTH = 48 in. Y3 BEAM LENGTH= 96 in. � SEISMIC CATEGORY = D H 1 Y_ (Fa = 1, Ss =1.49) Y1 L J` p �. COLUMN BEAM (&-_, Level 1 CONNECTOR C) Level 1 OK OK OK. 3 X 3 X 0.088 3 X 2.5 X 0.059 Three Pin Connector Steel = 42000 psi Steel = 42000 psi Stress = 58% Stress =56% Max Static Capacity = 2779 lb. Stress = 90% COLUMN BACKER BEAM @ Level 2+ CONNECTOR L). Level 2+ OK OK None 3 X 2.5 X 0.059 Three Pin Connector Max Static Capacity = 2779 lb. Stress = 41% Stress = Stress = 90% BRACING BASE PLATE OK OK OK HORIZONTAL DIAGONAL 8 in X 5 in X 0.375 in 1.5 X 1 X 0.06 1.5 X 1 X 0.06 Steel = 36000 psi MBase = 5168 in. lb. Stress = 18% Stress = 23% Stress = 52% SLAB & SOIL OK ANCHORS OK Simpson Strom Bolt 2 ESR-3037 Slab = 6" X 2500 psi Pullout Capacity = 944 lbs. Shear Capacity = 1016 lbs. Soil Bearing Pressure = 1000 psf 0.5" X 2.75" Min Embed. Slab Puncture Stress = 12% No. Of Anchors = 2 per Base Plate Slab Bending Stress = 15% Anchor Stress = 30% SEMIC PROJECT POP GOURMET POPCORN FOR MR. RACKS LLC. MATERIAL HANDLING ENGINEERING SHEET NO. 5 TEL : (909)869 - 0989 FAX: (909)869 - 0981 CALCULATED BY TC. FT ATT A-NTTT(` cTT?T'FT 13MArYNTA r-n 017AQ DATE T i112f Ynl c LOADS AND DISTRIBUTION: TYPE 48x96 t n 1 1 Fn Determines Seismic Base Shear per Section 1613.1, Chap 2209, of the 2012 IBC. EL5 FS EL4 F4 Seismic Category: D Fa: 1.00 Eta F3 Number Of Levels: 2 Ss: 1.49 eL ` F2 wPL (Sum of product loads) : 5000 lbs Ie: 1.00 Et , F i wDL (Sum of dead loads): 200 lbs Rw (Longitudinal): 6.00 TOTAL FRAME LOAD: 5200 lbs Rw (Transverse): 4.00 LONGTUDLNAL DIRECTION TRANSVERSE DIRECTION V _2/3 F,'SS, IF'(((0.67)'NPL)+uDz1 0.75 0.67 T� _2/3 ,•�,-I,-(((0.67)-Wj+J°L� Q.75 Q.67 L""E — R T,a„s N% [(2/3) X 1 X 1.49 X 1 X (((0.67)5000) + 200) / 6] X 0.75 X 0.67 [(2/3) X 1 X 1.49 X 1 X (((0.67)5000) + 200) / 4] X 0.75 X 0.67 i L°"g 295 lbs VTrans 443 lbs F; = T% W,H, WiH h, LONGITUDINAL TRANSVERSE Levels 11Jx W,.ha. f Yt%� 11 t.ha J i 1 72 2,600 187,200 98 2,600 187,200 148 2 144 2,600 374,400 197 2,600 374,400 295 561,600 295 lb, 561,600 4431bs e �3 MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 - 0981 161 ATLANTIC STREET. POMONA, CA 91768 PROJECT POP GOURMET POPCORN FOR MR. RACKS LLC. SHEET NO. 6 CALCULATED BY TC DATE 1/23/2015 LONGITUDINAL ANALYSIS: TYPE 48x96 THE ANALYSIS IS BASED ON THE PORTAL METHOD, WITH THE POINT OF CONTRA FLEXURE OF THE COLUMNS ASSUMED AT MID -HEIGHT BETWEEN BEAMS, EXCEPT FOR THE LOWEST PORTION, WHERE THE BASE PLATE PROVIDES ONLY PARTIAL FIXITY, THE CONTRA FLEXURE IS ASSUMED TO OCCUR CLOSER TO THE BASE. (OR AT THE BASE FOR PINNED CONDITION, WHERE THE BASE PLATE CANNOT CARRY MOMENT). Mlipper. + MLower — MConn'R' + MConn'L' Mi-n Fn MCarn'R' — MConn'L' M5-5 h FS MConn ' 2__ Mlipper + MLower M4-4 h5 _ Mlipper + MLower F4 MConn — 2 + MEnds h4 M3-3 F3 li+ Lone 148lbs col — 2ll- Fl hl MBase = 5168 in/lb M base FRONT ELEVATION LEVELS hi .f i AXIAL LOAD MOMENT MEnds Mcomi 1 2 70 72 49 98 2,600 1,300 5,192 3,564 4,308 4,308 8,686 6,090 SAMPLE CALL. Ml-I = (Vcol - hi) — MBase = (148 lbs X 70 in) - 5168 in/lb = 5,192 in/lb ei5 PROJECT POP GOURMET POPCORN FOR MR. RACKS LLC. MATERIAL HANDLING ENGINEERING SHEET NO. 7 TEL : (909)869 - 0989 FAX; (909)869 - 0981 CALCULATED BY TC 161 ATLANTIC STREET, POMONA. CA 91768 DATE 1i23!2015 COLUMN ANALYSIS: TYPE 48x96 ANALYZED PER AISI AND THE 2012 IBC. SECTION PROPERTIES BASED ON THE EFFECTIVE SECTION. P = 2600 lbs M = 5192 in/lb K, • L�. R,. = 1.7 X 70111 / 1.3in KL = 92.7 Max = 92.7 Kx - L) R - — 1 X 44in / 1 in R,; = 45.7 Axial II' E F� _ = 33.8 KSI k l/ f Max F,, — = 21 KSI 2 Since: F, > Fi,/2 F = 42 KSI X [I - 42 KSI / (4 X 33.84917KSI)] F;, = F3. 1- ' 4 F, = 29 KSI Pn =Aeff • F,, = 0.655 in^2 X 29 KSI = 18976 lbs Pp = S 1, = 18976 lbs / 1.8 = 10542 lbs P 0.2.5 P" Since: P > 0.15 P C�nx M _ < 1 Check: —+ P" Max cra. MVield = M„ = S`. - F,. = 0.71765 In^3 X 42000 PSI= 30141 in/lb M Max = . = 30141 / 1.67 = 18049 in/lb S2f II' EI PC7- = _ (3.14159)^2 X 29500 KSI X 1.0788 / (1191n.)^2 = 22180 lbs Kx - Lx )` 1 P (1 / (1 - (1.8 X 2600 lb / 221801b)))^-1 = 0.79 l—�S2c• PC7- (2600 lb / 10542 lb) _ (0.85 X 5192 in/lb / 18049 in/lb X 0.79) = 0.56 < 1 (56%) SECTION PROPERTIES A 3 in B : 3 in t : 0.088 in Aeff : 0.655 in^2 Ix 1.0788 in^4 Sx : 0.71765 in^3 Rx : 1.2831 in Iy 0.6065 in^4 Sy 032632 in^3 Ry : 0.962 in Kx :1.7 Lx : 70 in Ky :1 Ly : 44 in Fy :42 KSI E : 29500 KSI f2c : 1.80 S2 1.67 Cirix : 0.85 Cb I E EIZMIC 5 MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 - 0981 161 ATT.ANT1C STRFFT P( N40NA CA 91769 DETERIVIIINE ALLOWABLE MOMENT CAPACITY Determine allowable en ing moment per Check Compression Flange for Local Buckling (B2.1) w=c-2•t-2•7•= 1.625-(2*0.059)-(2*0.15 = 1.21in w/t = 1.21 / 0.059 = 20.51 A = (1.0521,rk-)• (w/t)F�,1E _ (1.052 / (4)^0.5) * 20.51 * (42 / 29000) ^ 0.5 = 0.41 PROJECT POP GOURMET POPCORN FOR MR. RACKS LLC. SHEET NO. 8 CALCULATED BY TC DATE 1 5 <= 0.673 Flange is fully effective y, : 1.17 Check Web for Local Buckling per Section (B2.3) 1'2 1.62 f (co'np) = F,, . (v31 y,) = 42 * (1.41 / 1.62) = 36.56 KSI 3 : 1.41 ))Cc . 1.38 f, (tenSlOt2) = F,. • (V1 I V2) = 42 * (1.17 / 1.62) = 30.33 KSI Ix 0.683 Sa.: 0.422 Yi = Af = 1.41 / 1.17 = -0.83 . t 0.059 0.15 k=4+2•(1-yr'+2•(1-yr�= Ft, : 42 4 + (2 * (1 +-0.83)^3) + 2 * (1 + -0.83) = 19.92 f 65 E : 29000 FlatDepth = w = y1 + J'1 = 1.17 + 1.41 = 2.58 in. TopFlange : 1.625 w/t = 2.58 / 0.059 = 43.73 <200 OK BottomFlange : 2.5 WebDepth : 3 A = (1.0521��' (w/t)' (Fi IE� (1.052 / (19.92)"0.5) * 43.73 * (36.56 / 29000)^0.5 = 0.37 b" = w = bl=be(3-yr)= 2.58*(3--0.83) b, = 2.58/2 b,+& = 9.88+1.29 2.58 = 9.88 = 1.29 = 11.17 Web is fully effective E EIZMIC3 MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 - 0981 161 ATLANTIC STREET, POMONA. CA 91768 PROTECT POP GOURMET POPCORN FOR MR. RACKS LLC. SHEET NO. 9 CALCULATED BY TC DATE 1 /2 3/2015 DETERMIINTE ALLOWABLE MOMENT CAPACITY (cont..) Determine allowable bending moment per AISI Determine Effect of Cold Working on Steel Yield Point (Fya) per Section A7.2 F,,a = c • F,,c + (1- c) F. Lco,» ,1, = L, _ (z12) • (7• + t12) = 3.14159 * (2 * 0.15 + 0.059) / 4 = 0.28 C=2•La/LJ+2•Lc= 2*0.28/(1.21+2*0.28) = 0.32 Lllonge-top = L( = = 1.21 in. m = 0.192 • (F„ /F})- 0.068 = 0.192 * (65 / 42) - 0.068 = 0.23 be = 3.69 • (�„ f�- 0.819 (f, �.f�? -1.79 = yj : 1.17 3.69 * (65 / 42) - 0.819 * (65 / 42)^2 - 1.79 = 1.96 l', : 1.62 y3 : 1.41 f f = (65 / 42) = 1.547 > 1.2 O )'Cg 1.38 7-It = (0.15 / 0.059 = 2.542 < 7 OK I,.: 0.683 S,.: 0.422 F, = b, F, 1.96 * 42 / (0.15 / 0.059)^0.23 f = 66.42 t : 0.059 r 0.15 .fya-top = 0.32 * 66.42 + (1 - 0.32) * 42 = 49.81 F• - 42 7" = va-bottom - Jya ' Ycg /(depth - ) .fu 65 .f{' c' E : 29000 49.81 * 1.38 / (3 - 1.38) = 42.43 TopFlange : 1.625 BottomFlange : 2.5 Check Allowable Tension Stress for Bottom Flange WebDepth LJlange-bot - L fb = Lbottom - 2 . Y - 2 • t = 2.5 - (2 * 0.15) - (2 * 0.059) = 2.08 Cbonom = Cb = 2 • L /(L,b + 2 ' Lc) _ 2*0.28/(2.08+2*0.28) = 0.21 Fy-bottom =Fyb . =C yc b •F..+(1-Cfi )•Ff = 0.21 * 66.42 + (1 - 0.21) * 42 = 47.13 F. 49.81 = 49.81 SEIZMIC MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 - 0981 161 ATT ANTICCTRFFT PCIMCINTA CA 0171W DETERMINE ALLOWABLE CAPACITY FOR BEAM PAIR PER SECTION 5.2 OF THE RMI, PT 11 Check Bending Capacity MCen,e,. = O ' M„ = W - L - f2• R,,, /8 S2 = LRFDLoadFactor =1.2 • DL + 1.4 • PL + 1.4.0.125 • PL for•DL = 2%ofPL Q= 1.2*0.02+1.4+1.4*0.125 Rn,=1—[(2•F•L)/(6•E•lb+3•F•L)] _ 1 - ((2 * 300 * 96) / ((6 * 29000 * 0.683) + (3 * 300 * 96))) PROJECT POP GOURMET POPCORN FOR MR. RACKS LLC. SHEET NO. 10 CALCULATED BY TC itATF 1/1):/7n1S = 1.599 = 0.72 Ifo = 0.95 Yi : 1.17 0 • Mn = 0 • FVa • S,: = 0.95 * 49.81 * 0.422 = 19.97 in y2 : 1.62y3 : 1.41 Mena = W - L • (1— R,n )I8 = y g : 1.38 2891 * 0.5 * 96 * (1 - 0.72) / 8 = 4857 in/ I,, :. 0.683 5,.: U.422 422 W = 0 • Mn .8 • (4gfBeams)1(L • Rn, Q) = t : 0.059 19.97 * 8 * 2 / (96 * 0.72 * 1.599) * 1000 = 2891 lb/pair 1' : 0.15 Fy 42 Check Deflection Capacity -f , 65 E : 29000 Amax __Ass • Rd TopFlange : 1.625 Rd=1—(4•F•L)1(5•F•L+10-E-Ib)= BottomFlange: 2.5 WebDepth : 3 1 - (4 * 300 * 96) / ((5 * 300 * 96) + (10 * 29000 * 0,683)) = 0.66 Amax = L/180 A,, =(5•W•L')1(384•E•Ib) L/180 = (5 • W f • Ra)1(384 • E • Ib •#gfBeams) ((5 * 2891 / 2000 * 96-3) / (384 * 29000 * 0.683)) * 0.66 W=(384•E•I.2)/(180.5 E-R,)= 384 * 29000 * 0.683 * 2 / (180 * 5 * (96-2) * 0.66) * 1000 Allowable Load = 2779 lb/pair 0.55 2779 lb/pair ESEMMIC� MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT FOR SHEET NO. CALCULATED BY DATE POP GOURMET POPCORN MR. RACKS LLC. it TC 1 /23/2015 ALLO'%NIABLE AND ACTUAL BENDING MOMENT AT EACH LEVEL Msranc = Wl'`A MAvow,sar,c — R7Ano,, * l / 8 MSeismic = MCo,m Manow.sessmic = Sx * Fb Level Mstatic MAllow.Static Mseismic MA11ow.S21smic Result 1 2 30768 30768 33348 33348 8686 6090 106.34 10634 GOOD GOOD SEIZMIC MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT POP GOURMET POPCORN FOR MR. RACKS LLC. SHEET NO. 12 CALCULATED BY TC DATE 1/23/2015 BEAM TO COLUMN ANALYSIS: TYPE 48x96 CONNECTION CAPACITY ON THE FOL7o7,TING PARAMETERS: 1. SHEAR CAPACITY OF PIN PinDiameter = 0.438In. F„ = 42000 PSI II AShear = Diameter ` •— = 0.1507 in^2 4 Pshear = 0•4 • F, ' As,,,, = 0.4 X 42000 X 0.1507 in^2 = 2531 lbs 2. BEARING CAPACITY OF PIN Column Thickness = 0.088 F„ = 65000PSI Q = 2.22 a = 2.22 PBearing = a • F, • Dia. • Col.ThielaiessI Q = 2.22 X 65000 X 0.438 X 0.088 / 2.22 = 2505 lbs 3. MOMENT CAPACITY OF BRACKET EdgeDist .=1.OIn. PinSpacing = 2 hi F„ = 42000 PSI C= P,+F+P = P,+P,(2.5/4.5)+P,(5/4.5) Tciip = 0.179In. Scip = 0.127I113 Mcapacih, = Saip * FBending = 0.127 In^3 X .66 X Fy = 3520 in -lb C • d = Mcapacih: = 1.667 P . d d = EdgeDist/2 = 0.5 Paip = Mcapaci,, /( 1.667 . d) = 3520 / (1.667 X 0.5) = 4223 lbs MINIMUM VALUE OF PI GOVERNS P, = 2505 lbs Mconn-.411a„ = [P, * 4.5]+ [P, * (0.514.5) * 0.5] = P1 X 1.667 AT LEVEL 1 = 14891in-lb > 8686in-lb OK e C MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT POP GOURMET POPCORN FOR MR. RACKS LLC. SHEET NO. 13 CALCULATED BY TC DATE 1/23/2015 TRANSVERSE ANALYSIS: BRACING: TYPE 48x96 IT IS ASSUMED THAT THE LOWER PANEL RESISTS THE FRAME SHEAR IN TENSION AND COMPRESSION. IF HORIZONTAL AND DIAGONAL MEMBERS ARE THE SAME, ANALYSIS WILL BE DONE ON THE DIAGONAL MEMBER AS IT WILL GOVERN. DIAGONAL BRACING: COMPRESSION MEMBER Ldiag= (L-6)2+(D—(2•BCOI))z = 44.9" Vtrans • LDiag Vdiag = d = 474 lbs k I (1 X 44.9444) / (0356) = 126.2 In rMin II=e F = = 17957.5 PSI e (k- l / )' rMin F, = 21000 F, < 21, F„ Fp = 17957.5 PSI Pn = Area • F„ = 4040 Ibs Qc=1.92 P. _C = 2104 Ibs Brace Stress = VDiag= 0.23 < 1 (23 %) P , I D P. Finaa F L SIDE ELEVATION Panel Height (L) = 22 hi Panel Depth (D) = 48 In Column Depth (B) = 3 In Clear Depth (d) _ (D - 2*13) = 42 EE IC 3 MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 PROJECT POP GOURMET POPCORN FOR MR. RACKS LLC. SHEET NO. 14 CALCULATED BY TC DATE 1/23/2015 POST -INSTALLED ANCHOR ANALYSIS PER ACI 318-11 APPENDIX D Assumed cracked concrete application Anchor Type = Simpson Strong Bolt 2 1/2" dia, 2.25" hef, 4.5" min. slab. ICU Report Number = ESR-3037 1.5 • hef = 3.38 in. Slab Thickness (hj = 6 in. Cal = 12 uSeCat_ad1 = 3.375 in ( Min. Slab Thickness \hmin) = 4.5 in. Cat = 12 uSeCa,_adj = 3.375 in. Concrete Stretio111 (f'r) = 2500 in. Diameter (da) = 0.5 3 •hef = 6.75 in. Nominal Embedment \hnonr / = 2.75 in. .Sl = 6 in. uSeS,.adf = 6 in. Effective Embedment (hef� = 2.25 in. Sz = 0 in. uSe.S._ Qa, = 0 in. Number of Anchors (77) = 2 e' N e'V From ICC ESR Report ASe lira S.I. Cmin Cac Alp,, 6 in. 0 in. 1.5! = 0.105 in.sq. S2 = 115000 psi Cat = 7 in. 7 in. = 6.5 �. 1,5cal S! 1;5c', 01eismic Adi. Strength Tension Capacity 1761 lbs 0.75 1')21 lbs Shear Capacity 1897 lbs 0.75 1422 lbs ASD Value Conversion Factor 1.4 944 lbs 1016 lbs SEIZMiC PROJECT POP GOURMET POPCORN FOR MR. RACKS LLC. MATERIAL HANDLING ENGINEERING SHEET NO. 15 TEL : (909)869 - 0989 FAX: (909)869 - 0981 CALCULATED BY TC 161 ATLANTIC STREET, POMONA, CA 91768 DATE 1/23/2015 ANCHOR ANALYSIS TENSION STRENGTH Steel Strength D.5.1 = 0.75 D.4.3. a) i) {' 0Nsa = OnAse✓,uu (0.75 * 2 * 0.105 * 115000) = 18112 lbs D-2 Concrete Breakout Strength ONcbg D.5.2 0 = 0.65 / D.4.3 c) ii) Condition B Category 1 A,,T, = (Cai.paj + .Si.naj + l .5het )' (CQ,.adj + S,.Aaj + 1.5her )= 86.0625 insq. AA:co = 9hef = 45.562.5 i Check if A.N,c <_nA,c. AAc/ArUco = 1.89 Vfcc,N = 1 D.5.2.4 V"ed_N = 1 D.5.15 Vc_.v = 1 D.5.2.6 kc = 17 D.5.22 Nb = kc Zo (. f ,c )0.5 (hef )` ' = 2869 lbs D-6 cy.N = 1 D.5.2.7 ON =O(A IA Xyr .X r ,Yr Rr .XAT ) D.5.2.1 cbg Nc Nco ec.,i� � ed.?4 t/ c.:'l rl cp,A b (0.65 * (86.0625/45.5625) * 1 * I * 1 * 1 * 2869= 3522 lbs Pullout Stength Op, D.5.3 0 = 0.65 DAA c) ii) Condition BCategoiy 1 D.5.3.6 ONyn = 0V'c,x, Np,, (.f 'c 12500 )o s N/A = N/A D.5.3.1 Steel Strength (o .) 18112 tbs Embedment Strength -Concrete breakout strength (ONcj 3522 lbs Embedment Strength - Pullout strength (0Np,� N/A E EiZMiC 3 MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91769 ANCHOR ANALYSIS SHEAR STRENGTH Steel Strength Ol , 0 = 0.65 OVso=On•0.6A,,f„. (0.65*2*0.6*0.105*11 = 9418lbs Concrete Breakout Strength OVcbg 0 = 0.7 AV = (1 .5ca1 + S1.adi + 1 .5ca1 )h,, = 252 in.sq. PROTECT POP GOURMET POPCORN FOR MR. RACKS LLC. SHEET NO. 16 CALCULATED By TC DATE 1 /23/2015 AVco = 3calhp = 216 in.sq. Check if AVc < nAwo AFc /AVco = 1.17 vfec,V = 1 Ved.V = 0.9 vlc,r = i V'h.T, = 1.73 d a = 0.5 in. Ie = 1 in. ,( Vb =,,// ((the smallerof7(1,11d. )0.2 (d` toys ), a r ff tlo ; c.11 s d 9�' �. p l� cal T 5 = 11818 lbs Ovcbg = O(AFc /APco /\V ec,P xvf.ed _V XV1 c,T' X V hY X Vbl/ 1 (0.7*1.17*1*0.9*1*1.73*11818)*1 = 15070lbs Concrete Pryout Stength oT Mpg 0 = 0.7 K,p=1 Ncbg = 5418 lbs 0 pD = OK�pNcbA (0.7 * 1 * 5418) = 3793 lbs Steel Strength (OVsa 1 9418 lbs Embedment Strength - Concrete breakout strength (0Vc" 15070 lbs Embedment Strength - Pryout strength (¢V 3793 lbs ,Po D.6.1 D.4.3 a) ii) D-28 D.6.2 D.4.3 c) 1) condition B D.62.5 D.62.6 D.6.2.7 D.62.8 D.6.2.2 D.3.6 D-33, D-34 D.6.2.1 D.6.3 D.4.3 e) i) Condition B D.6.3.1 D.6.3.1 E EIZMIC5 MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 - 0981 161 ATLANTIC STREET, POMONA, CA 91768 BASIC LOAD COMBINATIONS 2012 IBC SECTION 2209 RMI / ANSI MH 16.1 I T= 443 lb ,a„s Product Load/2 (PL) = 2500 lb BASIC LOAD COMBINATION 1: DL 1.0 * 100 = 100 lb 2: DL + PL + LL + (Lr or SL or RL) 100 + 2500 + 0 + 0 = 2600 lb PROJECT POP GOURMET POPCORN FOR MR. RACKS LLC. SHEET NO. 17 CALCULATED BY TC DATE 1/23/2015 V = 295 lb = 0.993 Long `�ds Dead Load/2 (DL) = 100 lb Seismic Load (EL) = 2204 lb 3: (0.6 * DL) + (0.75 * 0.6 * PLapp) - (0.75 * WL) (0.6 * 100) + (0.75 * 0.6 * 1675) + (0.75 * 0) = 814 lb 3: ((0.6 - (0.11 * Sds)) * DL) + (0.75 * (0,6 - (0.14 * Sds)) * PLapp) - (0.75 * 0.67 * EL) (0.6 - (0.11 * 0.993)) * 100 + (0.75 * (0.6 - (0.14 * 0.993))) * 1675 - (0.75 * 0.67 * 2204) = -479 lb 4: DL + (0.75 * PL) + LL + (Lr or SL or RL) + (0.75 * R7L) 100 + (0.75 * 2500) + 0 + 0 + (0.75 * 0) = 2600 lb 4: (1 + (0.11 * Sds)) DL + (0.75 * (I + (0.14 * Sds) * PLapp) + (0.75 * 0.67 * EL) (1 + (0.11 * 0.993)) * 100 + (0.75 * (1 + (0.14 * 0.993))) * 1675 + (0.75 * 0.67 * 2204) = 2649 lb 5: DL + LL + (0.5 * (SL or RL)) + (0.88 * PL) + IL 100 + 0 + (0.5 * 0) + (0.88 * 2500) + 625 = 2925 lb eSEIZMICPROTECT POP GOURMET POPCORN FOR MR. RACKS LLC. MATERIAL HANDLING ENGINEERING SHEET NO. 18 TEL : (909)869 - 0989 FAX: (909)869 - 0981 CALCULATED BY TC 161 ATLANTIC STREET, POMONA, CA 91768 DATE 11123/2015 OVERTURNING ANALYSIS: TYPE 48x96 ANALYSIS OF OVERTURNING WILL BE BASED ON SECTION 2209 & 1613.1 OF THE 2012 IBC FULLY LOADED Total Shear = 443 lbs Mort = Vha„s • Ht W Fr MOW = 443 X 120 = 53160 in/lb i MS, = I (WPL + WDL /' d/2 Ms, _ (5000 + 200) X 48/2 = 1.24800 in/lb 53160 - 124800 / 48 P,yL,f, = 1 MO1? — Mr, = 1492 lbs. Puplift <= 0 No Up Lift d _ 1Xwt + Msr / _ (53160 + 124800) / 48 �L1aYDown — d = 3708lbs. TOP SHELF LOADED Shear = 337 lbs M°,., = Vr°y • Ht Mori = 337 X (144 + ((72 - 10) / 2)) Ms, _ I (WDj + WDJ d12 Ms, _ (2500 + 200) X 48 /2 _ 1(M""f — Ms, PliyLift — d ANCHORS No. of Anchors : 2 Pull Out Capacity : 944 Lbs. 58962 in/lb 64800 in/lb _ (58962 - 64800) / 48 _ -122 lbs. Puplift<=0 No up Lift Shear Capacity : 1016 Lbs. COMBINED STRESS Fullv Loaded = (0 / 944 X 2))+ ((443 /2)/(1016 X 2)) = 0.11 Top Shel{Loaded = (0 / (944 X 2))+ ((337 /2)/(1016 X 2)) = 0.08 CROSS AISLE ELE%/ATION Seismic UpLi{t Critical (LC#3) _ ((479 / 944 X 2))+ ((443 /2)/(1016 X 2))) / 1.2 = 0.3 Sec 4.22 ESR-3037 USE 2 Simpson Strong Bolt 2 1/2" dia, 2.25" hef, 4.5" min. slab. Anchors per BasePlate. (or approved equal) V E EIZMIC MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 - 0981 161 ATLANTIC STREET. POMONA. CA 91768 PROJECT POP GOURMET POPCORN FOR MR. RACKS LLC. SHEET NO. 19 CALCULATED BY TC DATE 1 /23/2015 BASE PLATE ANALYSIS: TYPE 48x96 THE BASE PLATE WILL BE ANALYZED WITH THE RECTANGULAR STRESS RESULTING FROM THE VERTICAL LOAD P, COMBINED WITH THE TRIANGULAR STRESSES RESULTING FROM THE MOMENT Mb (IF ANY). THERE ARE 3 CRITERIA IN DETERMINING Mb. THEY ARE 1. MOMENT CAPACITY OF THE BASE PLATE, 2. MOMENT CAPACITY OF THE ANCHOR BOLTS, AND 3. Vcol*h/2 (FULL FIXITY). Mb IS THAT SMALLEST VALUE OBTAINED FROM THE 3 CRITERIA ABOVE. Pc117 = 2600lbs MBase = 5168 in/lb P _ Pcor A D•B _ Mb .fb — D B2/6 2•b, fb2 = B fb Jbl = fb _1b2 Base Plate Width (B) = 8 in b = 3 in Base Plate Depth (D) = 5 in bl = 2.5 in Base Plate Thickness (t) = 0.375 in Fy (base) = 36000 PSI 65 PSI 96.9 PSI 60.56 PSI = 36.34 PSI _ 1, — 12 r Mb — �,2 — 2 `fa + .fbl + .67.fb2 l Mb = 442.85 in/lb 1•t" SBase _ 6 FBase = .75F,• .fb Mb Fb S Bose • FB., 0.02 in/cb 36000 PSI 0.52 <= I OK fb tb 2 it+ 1 E MIC MATERIAL HANDLING ENGINEERING TEL : (909)869 - 0989 FAX: (909)869 - 0981 PROTECT POP GOURMET POPCORN FOR MR. RACKS LLC. SHEET NO. 20 CALCULATED BY TC 101 A 1 LAiN lit-, 51 Kht I, YUMUNA, UA 91 106 DATE 1231201 J SLAB AND SOIL: TYPE 48x96 THE SLAB WILL BE CHECKED FOR PUNCTURE STRESS. IF NO PUNCTURE OCCURS, IT WILL BE ASSUMED TO DISTRIBUTE THE LOAD OVER A LARGER AREA OF SOIL AND WILL ACT AS A FOOTING. PUNCTURE Psr°fic = 2600 lbs Pseisndc = 1108 lbs of = 53160 in -lb P..=(1.2+0.2Sds)•DL+(0.85+0.2Sds)•PL+LOEL = 4966lbs (Gray. - seis. critical) + F = 338 ��' .fc= P putt = 133 PSI 2.66 • A f 'c —< Ap,n7ct=[(B+t)+(W+t)]•2•t _ — 300 sq. in. max F,, Ap„» ct ' Fpnnct = 0.12 SLAB TENSION P,,,,_. • 144 Asort — = 538 sq. in. 1.3 3 fso;, = 23.19 in B = B•W +I = 12.32in b=L —B 2 = 5.43 in wb' _ 1.33 • fs°;, • b' ltl°°"c — 2 144.2 = 136 in -lb _ 1-t' 'Scone — 6 = 6 cb. in. Fc°"c = 50 .fc = 150 PSI .fb MConc = Fb S0.15 c°»c ' Fco, OK BASE PLATE B = 8 in W = 5in Frame Depth d = 48 in CONCRETE 2500 PSI f,= t = 6 in 0 = 0.6 A = 0.6 SOIL (soil = 1000 PSF City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director July 9, 2015 LISA LYNN 500 SW 16 ST RENTON, WA 98057 RE: Application No. D15-0025 POP GOURMET POPCORN 13400 INTERURBAN AVE S Dear LISA LYNN: Permit application D15-0025 for the work proposed at POP GOURMET POPCORN (13400 INTERURBAN AVE S) has not been issued by the City of Tukwila Permit Center. Per the International Building, Residential, and Mechanical Codes as well as the Uniform Plumbing Code and/or the National Electric Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of COMMENTS OUT and is due to expire 08/02/2015. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is completed for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that your permit is not issued, we do not receive your written request for extension, or your request is denied your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, P� c. Bill Rambo Permit Technician File No: D15-0025 V 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 9 Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development February 18, 2015 JOSHUA FRY 500 SW 16 ST RENTON, WA 98057 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D15-0025 POP GOURMET POPCORN - 13400 INTERURBAN AVE S Dear JOSHUA FRY, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size l 1x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. (BUILDING REVIEW NOTES) 1. The rack layout conflicts with the required emergency common path of egress travel to the exits. Revise the rack layout consistent with the approved plan permit D14-0336, where egress paths of travel shall not be blocked or compromised. If the plan for D14-0336 is to be altered for the rack storage, that plan shall require a revision to the egress plan and reviewed for code compliance. FIRE DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments. • 1) Please provide a detailed description of the commodities to be stored in the racks. 2) What will be the total storage height? 3) What is the ceiling height? 4) What is the existing ceiling fire sprinkler density in the storage area? 5) What is the temperature rating of the existing fire sprinkler heads? Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300.Crnithrantvr Rnulavnrrl ,G.ity #lnn • Tulruiiln Wnchinotnn 9RIRR a Phnna ?n6_431_3670 a Fnr ?n6-43I-3s6s If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. D15-0025 6300 Southcenter Boulevard Suite #100 • Tukwila Washinoton 98188 • Phone 206-431-3670 • Fax 206-437-3665 ~PERMIT C00RD COPY -' PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0025 DATE: 07/17/15 PROJECT NAME: POP GOURMET POPCORN SITE ADDRESS: 13400 INTERURBAN AVE S Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: �� fit- S- 4YIng Divisiovn Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: 4A1 v-V'\ 1 REVIEWER'S INITIALS: we/ W -1% Fire Prevention 0 Planning Division ❑ Structural ❑ Permit Coordinator 0 DATE: 07/21/15 Structural Review Required ❑ DATE: DUE DATE: 08/18/15 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0025 DATE: 02/02/15 PROJECT NAME: POP GOURMET POPCORN SITE ADDRESS: 13400 INTERURBAN AVE S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter #, DEPARTMENTS: 1jrBinding Division Revision # after Permit Issued Pam mff 2-13 - K Fire Prevention IN Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 02/03/1.5 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/03/15 Approved ❑ Approved with Conditions ❑ Corrections Required d (corrections entered in Reviews) Notation: Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: ( lV Departments issued corrections: Bldg Fire Ping El El Staff Initials: (K 1211 MO13 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.Tukwila'Y�7A.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7 Plan Check/Permif- Dumber: l r t ,I Response to Incomplete Letter # Response to Correction Letter # I Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Addre Contact Persoi Summary of Revision: Sheet Number(s)° "Cloud" or highlight all areas of revision including d revisio PEA AI CFN'1`FP c Received at the City of Tukwila Permit Center by: �' Entered in TRAMT on �?-- I 7--t—s- MR RACKS LLC Page 1 of 2 Home Inicio en i spafiot € Contact Safety C) Washington State Departattent of Labor & Industries MR RACKS LLC Search L&I A-Z Index ' Help My Secure L&I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 500 SW 16TH ST Principals RENTON, WA98057 425-207-0058 Ferguson, Carey Scott, PARTNER/MEMBER KING County Ferguson, Julie Lynn, PARTNER/MEMBER Ferguson, Carey Scott, AGENT GONSER, BRETT, PARTNER/MEMBER (End: 04/30/2013) MCLENDON,ROBERT,PARTNER/MEMBER (End: 04/30/2013) Doing business as MR RACKS LLC WA UBI No. Business type 602 779 014 Limited Liability Company Governing persons CAREY FERGUSON JULIE FERGUSON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ..................................................................... . Meets current requirements. License specialties GENERAL License no. MRRACRL924BN Effective — expiration 01/0312008— 01/17/2016 Bond AMERICAN CONTRACTORS INDEM CO $12,000.00 Bond account no. 100031015 Received by L&I Effective date 01/03/2008 12/20/2007 Expiration date Until Canceled Insurance ............................... Ohio Security Ins Co $1,000,000.00 Policy no. BKS1654574031 Received by L&I Effective date 05/27/2016 06/29/2015 Expiration date httnQ•//cariira lni w5i anv/varifv/Tlatail acnv71TUT=A0777401aR7T Tr—>\auu APVT o')nUXTR,Q AAll— IP21 P)01 C I ILI i✓//�13 GA. �. �\Y� � 11 GA. FORMED CONNECTION MEMBER II I i I I i V WELD TO BASE PLATE ii i i i U J II I C I I I I I ATTACH COLUMN TO BASE PLATE W/ u I I I 1 (4) 5/16"0 x 3/4 ii i yl I I I 1 3/8" BOLT (GRADE 5) i 1 i i ��'� I THK. 9/16 O 1 41 �1% i ii i HOLES 2 SLAB ON GRADE 1 2 /2" 0 ANCHOR .., _ v e <.. 2 3/4" MIN. •. e EMBMNT. d e SOIL (2) ANCHORS REQ'D PER BASE PLATE 1 N ATTACH W/ (1) 5/16"0 X 3" GR. 5 BOLT �2j BASE PLATE -A TYPICAL BRACE TO COLUMN CONNECTION 1 COLUMN 3 ANCHOR 4 HORIZONTAL &DIAGONAL BRACE GENERAL CONFIGURATION iSTUD TYPICAL BEAM TO COLUMN CONNECTION t1 3/8"� SAFETY CLIP I ® 1 I I I 1 ® 1 I 6 1 I 7 GA.* 6 CONNECTOR 5 BEAM TYPE 48" x 96" _--J96" 8" FRONT VIEW SIDE VIEW SPECIAL INSPECTION FOR STORAGE RACKS (OVER 8 FEET) (IBC 1707.5.11.7) Periodic special inspection is required during the anchorage of storage racks 8 feet or greater in height in structures assigned to Seismic Design Category D, E or F. and TABLE 1705.3 (#4) Inspection of anchors post - installed in hardened concrete members. NOTES: 1. DESIGNED PER SECTION 2209 OF THE 2012 IBC.. Fa = 1 & Ss = 1.49 2. STORAGE CAPACITY: 2,500# PER LEVEL 3. ASTM A1011 FOR SHAPE Fy = 42,000 PSI GRADE 42. 4. ALL BOLTS: A307 (UNLESS OTHERWISE NOTED). 5. ANCHORS: SIMPSON STRONGBOLT 2, ICC #ESR-3037. 6. PERIODIC SPECIAL INSPECTION IS REQUIRED DURING THE ANCHORAGE OF STORAGE RACKS 8 FEET OR GREATER IN HEIGHT IN STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY "D", "E" OR "F". (SECTION 1707.5) 7. CONCRETE: 6" THICK x 2,500 PSI. 8. SOIL BEARING PRESSURE: 1,000 PSF. MEW" " � I� N � 811f1 A1111�011�. �lq�Cln > II does no aulltialag � vi�ll�ioil code 'nal or. AooNpt of l�pplowd Ctitty of Tukwila .DII DIVISIAV REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: pe%visions vvil require a new plan submittal and may include additional plan review fees. REVIEWED FOR CODE COMPI_IANC APPROVED JUL 2 9 2015 City of Tukwila BUILDING DIVISIC Dt5-oo04011-goo ,mlechanicai �i"6�'m'irlrtg OGas Piping RECEIVED CITY OF TUKWVILA FEB,0 2 2015 PERMIT CENTER Z= �O O U) a�� a>5 �Qa W z� Q W-Cr-1 =m� QW� W a z ao O W (L X T 0 Q z 0 a U U) LL! G m w Q 0 >Q<1aa SEIZMIC EST. 1985 SEEMIC ENGINEERING, INC. 161 Atlantic Street Pomona, California 91768 Tel.(909)869-0989 Fax(909)869-0981 DRAWN BY: P,O,/T,C, DATE: 01 /23/15 LAST REV. BY: REV. DATE: TYPE: NWL SCALE: N.T.S. APRV'D BY: SAL E. FATEEN wx IST ME-' � EXPIRES 04-12-2016 DESCRIPTION: STORAGE RACK DETAILS STORAGE RACK ELEVATIONS DRAWING NUMBER: 15-0101-A O R� rQ0Cb ,ip .P � 1e_6te Min 5e-'1611 X� 4rXW 42"X96 4rXW a R�t�'t `" For Rodent Control (TYP.) $ee :a; m W A REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 9 2015 City of Tukwila BUILDING DIVISION d Ln ce 00 Ln C 0 UZ m N d' Ln � C)N v- �aC_LL U tL W .,, L 57 0 "� �� V) w < oC UU) 3� LU WzX U0 nz� ce . a �U •��W F-w Ito_ off,? 0 Q Ln m r W ce °- �- 2 c "' r' , L1 M CD W CD Cr) ::D w 00 Q p CL O �-- c— zv O (D w Q DRAWN BY: JF SCALE: 1 /16" = 1-0" DATE: 7-16-15 DRAWING NO: DECEIVED CHECKED BY: CITY OF TUKWILA JUL 17 2015 SHEET NO. fto PERMIT CENTER OF 2 SHEETS