Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D15-0032 - RPI DIGITAL PRINTING - TENANT IMPROVEMENT
RPI DIGITAL PRINTING 3325 S 116 ST D15M0032 Citv of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Izov Parcel No: 0923049068 Address: 3325 S 116TH ST 161 Project Name: RPI DIGITAL PRINTING DEVELOPMENT PERMIT Permit Number: D15-0032 Issue Date: 2/23/2015 Permit Expires On: 8/22/2015 Owner: Name: EPROPERTY TAX INC DEPT 207 Address: PO BOX 4900, SCOTTSDALE, WA, 85261 Contact Person: Name: ROYCE BERG Phone: (206) 230-6648 Address: 301180TH ST SE, MERCER ISLAND, WA, 98040 Contractor: Name: GATEWAY CONSTRUCTION SVS Phone: (206) 621-9111 Address: 5602 2ND AVE S , SEATTLE, WA, 98108-2409 License No: GATEWCS992C3 Expiration Date: Lender: Name: SELF FUNDED - RPI PRINTING Address: , "I DESCRIPTION OF WORK: EXPAND PRODUCTION FLOW LINES FOR PRINTING STORAGE. REMOVE OLD TENANT DEMISING WALL AND RELOCATE INTERIOR OVERHEAD DOOR. PROVIDE NEW ACCESS TO EXISTING OFFICE AREA. REMOVE END WALL SECTIONS TO WIDEN MATERIAL AISLE. Project Valuation: $35,000.00 Fees Collected: $1,285.28 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIIB Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws re lating construction or the performance of work. I am authorized to sign and obtain this development per t ree to the conditions attached to this permit. Signature: L- V #0 M-� Date: 41d� /1/-/� Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 34: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 11: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 12: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Maintain fire extinguisher coverage throughout. 16: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 17: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 18: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 19: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 20: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 21: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.6) 22: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 23: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1011.6.3) 24: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 28: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 26: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.S.3.3) 25: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 29: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 31: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 30: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 32: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 33: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 3S: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 27: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 36: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 37: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING CITY OF TUKI , .A Building Permit No. Comntunity Development Department • t `` Public Works Department Project No. -04 .� Permit Center "-1 6300 Southcenter Blvd., Suite 100 Date Application Accepted: Tukwila, WA 98188 Date Application Expires: ©) — Itttp: iw�t \\:.TukyN,ilaWA., (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.. 092304-9068 Site Address: 3325 South 116th Street Suite Number: Floor: I Tenant Name: RPI Digital Printing New Tenant: ❑ .....Yes ®..No PROPERTY OWNER RREEF America REIT II Corp. MMMM7 Washington Name: C/O CBRE / Asset Services, Amber Stratton Address: 20415 72nd Ave S., Suite 210 City: Seattle State: Wa zip: 98101 CONTACT PERSON — person receiving all project communication Name: Royce Berg, LPN Architects Address: 3011 80th Ave Se City: Mercer Island State: Wa zip: 98040 Phone: (206) 230-6648 Fax: (206) 320-6647 Email: royce@lpnarchitects.com GENERAL CONTRACTOR INFORMATION Company Name: Gateway Construction Services/Bill F Address: 5602 Second Ave South City: Seattle State: Wa Zip: 98108 Phone: (206) 621-9111 Fax: (206) 621-9113 Contr Reg No.: GATEWCS992C3 Exp Date: 03/04/2016 Tukwila Business License No.: BUS-0101708 ter ARCHITECT OF RECORD Company Name: LPN Architecture and Planners Architect Name: Royce A. Berg Address: 3011 80th Ave Se City: Mercer Island State: Wa Zip: 98040 Phone: (206) 230-6648 Fax: (206) 320-6647 Email: royce@lpnarchitects.com ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Cash by Tenant - RPI Address: City: State: Zip: H:\Applications\Forms-Applications On Line\201 I ApplicationsTennit Application Revised - 8-9-1 I.docx Revised: August 2011 Page 1 of 4 bh BUILDING PERMIT INFORMATIC 206-431-3670 l Valuation of Project (contractor's bid price): $ 35,000 Existing Building Valuation: $ 6,428,400 Describe the scope of work (please provide detailed information): Expand production flow lines for printing storage. Remove old tenant demising wall and relocate interior overhead door. Provide new access to existing office area. Remove end wall sections to widen material aisle. Will there be new rack storage? ❑..... Yes ®.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below ExistingInterior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lst Floor 48,476 51 III-B B, F, S Mezzanine 2,981 III-B B P Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 120 Will there be a change in use? El ....... Yes ....... No FIRE PROTECTION/HAZARDOUS MATERIALS: Compact: 0 Handicap: 6 If "yes", explain: 0 ....... Sprinklers 0 ....... Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ....... Yes Z .......No If "yes, attach list of materials and storage locations on a separate 8-112 " x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\201 I ApplicationsTernin Application Revised - 8-9-11 doex Revised: August 2011 Page 2 of 4 bn PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Royce A. LPN Architects Mailing Address: 3011 80th Ave SE Date: Day Telephone: (206) 230-6648 Mercer Island WA 98040 City State Zip 1-1:AApplications\Forms-Applications On LineA201 I ApplicationsVPermit Application Revised - 8-9-1I.docx Revised: August 2011 bh Page 4 of 4 DESCRIPTIONS PermitTRAK ACCOUNTQUANTITY PAID $1,285.28 D15-0032 Address: 3325 S 116TH ST 161 Apn: 0923049068 $1,285.28 DEVELOPMENT $1,247.61 PERMIT FEE R000.322.100.00.00 0.00 $753.40 PLAN CHECK FEE R000.345.830.00.00 0.00 $489.71 WASHINGTON STATE SURCHARGE 13640.237.114 0.00 $4.50 TECHNOLOGY FEE $37.67 TECHNOLOGY FEE TOTALPAIDBY RECEIPT: .44. R000.322.900.04.00 0.00 $37.67 Date Paid: Monday, February 09, 2015 Paid By: REISCHLING PRESS INC Pay Method: CHECK 031341 Printed: Monday, February 09, 2015 1:42 PM 1 of 1 ,+'WYMMS Ird INSPECTION RECORD 6 Retain a copy with permit ell k:ic)TION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd,, #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 436-9350 Project. 113ate Type of Insp _cti;�nr 7 Address: f a . #W CaII Special Instructions: Date Wanted: a.m. --Z' pm. Requester: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 0 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro, t- .je Er4 =on: Typgect R,,, Address: 5a Date Called:. et= Special Instructions: Date Wanted: a. Requester /I Date No: 2106-7o�6 0 00 __j Inspector. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100, Call to schedule reinspection. SO Ea. INSPECTION RECORD Retain a copy with permit $7- INSPECWIN NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prgj'ecmt-. Type of Inspection', .2 Address: Date Called: Special Instructions: XMIRequetter. Date Wanted: p.rn, 3-, P one No: inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD ' T)I t�Q3 Z f Retain a copy with permit IF - r - O2 2— INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project -"...,Type of Inspection: Address: 5, Contact Person: Suite #: Z Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: -Occupancy Type: Inspector: f S Date: 31j6fj� Hrs.: �0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. niiiing Aaaress Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 R2 and R3 11interior ■1[!I11X111[!l►Z!IIIIIIE=1* %J I-011fill 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address RPI Digital Printing Date 2/6/2015 3325 South 116th Street For Building Department Use Tukwila, Wa. FILE COPY -- Applicant Name: LPN Architects and Planners / Royce A. Berg AIA Applicant Address: 3011 80th Ave SE, Mercer island, Wa. 98040 Applicant Phone: 206-230-664e Project Description ❑ New Building ❑ Addition JZ Alteration ❑ Plans Included Lighting Compliance 0 Lighting Power Density Calculations 0 Total Building Performance Path (If Total Building Performance then only LGT-CHK is required.) Interior Lighting 0 Buildinq Area Method Space -by -space Method Compliance Option - - Interior Lighting System CODE COMPLIANCE Description Are - Briefly describe lighting system type and features. FEB 18 2015� - ( {� J �rry of Ttfl(V. i1 Additions and Change of Space Use (C101.4.3 & C101.4.4) BUILDING DIVIS10R ❑ Addition area or Change of Space Use area complies with all applicable provisions as stand alone project ❑ Addition area or Change of Space Use area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use scope. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) ❑ 60% or more of luminaires in space replaced Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing) lighting wattage of project scope ❑ Less than 60% of luminaires in space replaced Provide Space -by -space Method (LTG-INT-SPACE) Compliance Form. Document existing total wattage in space and proposed (including existing) lighting wattage of project scope ❑ Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased ❑ New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 ❑ New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. ❑ Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. No changes are being made to the interior lighting and space use not changed. b C)0,3 2, RECEIVED CITY OF TUKWILA FEB 0 9 2015 (PERMIT CENTER 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 R2 and R3 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address RPI Digital Printing Date 2/6/2015 3325 South 116th Street For Building Department Use Tukwila, We. Applicant Name: LPN Architects and Planners / Royce A. Berg AIA Maximum Allowed Lighting Wattage Location (plan #, room #, or ALL) Space Type* Allowed Wafts per ft2 Gross Interior Area in ft2 Wafts Allowed (watts/ft2 x area) Atrium** Enter Height: Retail Display Allowance from LGT-INT-DISPLAY * Select Table C405.5.2(2) category from drop down menu. ** For atriums, indicate height.Allowed wattage for first 40 feet is 0.03 W/ft. ht., above 40 feet is 0.02 W/ft. ht. Proposed Lighting Wattage Area Allowed Watts Total Location (plan #, room #, or ALL) Fixture Description (Include exempt equipment per Note 3) Number of Fixtures Watts/ Fixture Watts Proposed Retail Display Lighting from LGT-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. gf)1g Washinntnn States Fnarnv CnriP Cmmnlianca Fnrms fnr Cnmmarcial ('rniin R1 nrid > 3 stnry R9 anrt R3 Lighting, Motor, andTransformer 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address RPx Digital Printing Date 2/6/2015 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2012 Washington State Nonresidential Energy Code. Applicability Code Location Building Department (yes, no, n.a.) Section Component Information Required on Plans Notes LIGHTING CONTROLS (Section C405.2) Yes C405.2.1 Manual lighting Lighting control schedule with type, locations served, 50% Bid controls lighting reduction method Design N.A. Lighting systems automatic shut-off capability - indicate C405.2.2.1 Automatic time method and location served on plans. Note locations where switch controls automatic shutoff is provided by other method (occupancy sensor, daylight controls, etc) N.A. Override switching Schedule with locations served - no single override switch exceeds an area of 5,000 SF Yes C405.2.2.2 Occupancy sensors Schedule of locations served Bid Design Yes C405.2.2.3 Daylight zones Bid Design N.A. Vertical fenestration Primary and secondary daylight zone areas indicated on plans N.A. Skylights Skylight daylight zone areas indicated on plans Yes 405.2.2.3., Daylight zone Lighting control schedule with dimming method and locations Bid controls served - no single daylight control zone exceeds 2,500 SF Design Yes Specific application Specific application lighting controls are independent of Bid C405.2.3 Controls general area lighting and controls for other lighting Design applications Yes Means of egress Lighting control schedule with method and locations served. Bid lighting Note luminaires that function as both normal and egress. Design N.A. Display lighting Lighting control schedule with type and locations served N.A. Accent lighting Lighting control schedule with type and locations served N.A. Hotel/motel guest Lighting control schedule with type and locations served rooms N.A. Supplemental task Lighting control schedule with type and locations served lighting N.A. Non-exempt lighting Lighting control schedule with type, applications served and equipment locations N.A. Non-exempt lighting Lighting control schedule with type, applications served and equipment locations C405.2.4 Exterior lighting Lighting control schedule with type, features and location controls served INTERIOR LIGHTING POWER Section C405.5 Yes C405.5.1 Total connected Schedule with fixture types, lamps, ballasts, watts per fixture Bid lighting power Design N.A. Space exceptions Space exceptions taken noted on plans or compliance form N.A. Lighting equipment Equipment exceptions taken noted on plans or compliance exceptions form Yes C405.5.2 Lighting power calculations N.A. Building Area Method Compliance form completed — proposed wattage per building area does not exceed maximum allowed wattage Yes Space -By -Space Compliance form completed — total proposed wattage does Method not exceed maximum allowed wattage Yes C405.4 Exit signs All internally illuminated exits sign are < 5 watts per side 1 CI EXTERIOR LIGHTING POWER Section C405.6 N.A. C405.6.2 Total connected lighting power Schedule with fixture types, lamps, ballasts, watts per fixture N.A. Exterior application Exterior application exceptions taken noted on plans or exceptions compliance form N.A. Lighting power Compliance form completed — proposed wattage for exterior calculations lighting plus base site allowed does not exceed max. allowed 2012 Washington State Enerqv Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Lighting, Motor,and Transformer PermitPlans 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address RPI Digital Printing Date 2/6/2015 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2012 Washington State Nonresidential Energy Code. Applicability Code Location Building Department (yes, no, n.a.) Section Component Information Required on Plans Notes N.A. C405.6.1 Exterior building Schedule with fixture types, lamps, ballasts, wafts per fixture; grounds lighting lumens per watt for fixtures > 100 watts ELECTRICAL POWER SYSTEMS Sections C405.7 ,C405.9, C405.12, C409.2.1 N.A. Electrical energy C409.2.1 consumption — whole Meters provided for whole building electric energy usage building N.A. Electrical energy C405.7 consumption — Individual dwelling unit electricity meters provided dwelling units N.A. C405.9 Transformers Indicate transformer size and efficiency on plans N.A. Variable speed C405.12.1 escalators and Variable speed controls provided moving walks N.A. C405.12.2 Regenerative drives Variable frequency regenerative drives provided for escalators COMMISSIONING Sections C405.13, C408.3, C409.4.4 N.A. C405.13 Commissioning Commissioning procedure developed for all applicable systems N.A. C408.3 Lighting controls Commissioning plan and functional test procedure developed N.A. C409.4.4 Electrical energy Commissioning plan and functional test procedure developed consumption meters N.A. Escalators & moving Commissioning plan and functional test procedure developed walks If "no" is circled for any question, provide explanation: PERMIT CSC 0 %d Pj PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0032 DATE: 02/09/15 PROJECT NAME: RPI DIGITAL PRINTING SITE ADDRESS: 3325 S 116 ST X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Bui ding Division Public Works PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: AM XJ& 2-(�r11� Fire Prevention Is Structural ❑ &Pt, K,(, 2- J K Planning Division a Permit Coordinator a DATE: 02/10/15 Structural Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/10/15 Approved ❑ Approved with Conditions Z Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/1812013 GATEWAY CONSTRUCTION SR"rS INC Page I of 2 ^ Washington State Department of ki Labor & industries Home tnic io en I. apafiol Contact Search L&I A-Z Iudcx Help My Secure 1A1 Safety Claims & Insurance Workplace Rights Trades & Licensing GATEWAY CONSTRUCTION SRVCS INC Owner or tradesperson 5602 2nd Ave. S. SACCO, RONALD SEATTLE, WA98108 206-621-9111 Principals KING County SACCO, RONALD, PRESIDENT NIELSEN. CRISTIAN. VICE PRESIDENT Doing business as GATEWAY CONSTRUCTION SRVCS INC WA UBI No. Business type 602 086 011 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active.................................................................. _...... Meets current requirements. License specialties GENERAL License no. GATEWCS992C3 Effective — expiration 02/26/2001— 03/0412016 Bond ............... TRAVELERS CAS & SURETY CO $12,000.00 Bond account no. 105165492 Received by L&I Effective date 08/21/2008 08/19/2008 Expiration date Until Canceled Insurance .......................... Travelers Indemnity Company Th $1,000,000.00 Policy no. DTC0527DO333IND12 Received by L&I Effective date 07/29/2014 08/01 /2012 Expiration date 08/01 /2015 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Cause no. 12-2-03868 4 Dismissed .............................. Complaint filed by Complaint against bond(s) or savings https:Hsecure.lni.wa.gov/verify/Detail.aspx?UBI=602086011&LIC=GATEWCS992C3&SAW= 02/23/2015 x a 0 v (U in 0 tU (U THE FOLLOWING BID DESIGNS AND DEFERRED SUBMITTALS ARE TAX ACCOUNT NO. 092304-9068 rC� U 2 X 4 LIGHT FIXTURE SECTION OR DETAIL NUMBERS A.C.T. A.F.F. ACOUSTICAL CEILING TILE INSUL INSULATION ABOVE FINISHED FLOOR REQUIRED FOR PERMITS AND APPROVALS FROM THE BUILDING LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 90-2-SS RECORDING NO (a- DETAIL - SECTION OR TARGET ALUM. INT. INTERIOR ALUMINUM' JT. JOINT OFFICIAL OR THE AUTHORITY HAVING JURISDICTION. NO WORK 9003121482 SD SHORT PLAT DAF - POR OF GOV LOT 3 & OF SE 1/4 2 X 4 NIGHT LIGHT FIXTURE DRAWING WHERE SECTION OR DETAIL IS DRAWN ASPH. ASPHALT MOD. ANODIZED JST. JOIST SHALL BE STARTED PRIOR TO THE APPROVAL OF THE BUILDING OFFICIAL OR THE AUTHORITY HAVING JURISDICTION. COPIES SHALL OF NE 1 /4 OF SEC 09-23-04 TGW POR OF GOV LOT 6 & OF SW 1 /4 � E 2 X 2 LIGHT FIXTURE BD. BLDG. BOARD BUILDING LAV. LAVATORY BE FORWARDED TO THE ARCHITECT AND COORDINATION OF THE OF NW 1 4 OF SECTION 10-23-04 - BAAP 70 FT RGT OF ENGR STA H % PARTIAL OR FULL SECTION T-1 BLK'G BLOCKING MAIL MATERIAL DISCIPLINES SHALL BE THROUGH THE GENERAL CONTRACTOR. 556+57.3 BEING A PT ON NELY MGN SHEET 1 OF 7 FOR R W SR 99 S / � TRACK LIGHTING BM. B.U.R. BEAM BUILT UP ROOFING MAX. MAXIMUM 118TH ST TO JUNCTION SSH NO 1-K APPROVED JULY 23, 1957 SD PT O RECESSED DOWNLIGHT 1 WALL OR DETAIL ELEVATION � MECH. MECHANICAL CENTER LINE MFR. MANUFACTURER SEPARATE PERMIT DESIGNER_JPHONE: BEING PT OF TANGENCY OF CURVE THRU POINT BEARING N 42-02-03 E T-1 CLG. MIN. MINIMUM CLOSE 748.51 FT TH SELY ALG SD MGN & SAID CURVE THRU C/A OF 04-26-56 O> RECESSED DIRECTIONAL DOWNLIGHT cLSR. CLOSER Mix. MIXTURE ARC DISTANCE OF 58.12 FT TH N 41-57-30 E 499.81 FT TH N O PENDANT LIGHT 1 COL COLUMN MTL METAL 1. ELECTRICAL WORK TO BE SELECTED 15-27-21 E 75.56 FT TO POB TH S 74-32-39 E 212.89 FT TH S INTERIOR FINISHED WALL ELEVATIONS CONC. CONCRETE N.I.C. NOT IN CONTRACT & LIGHTING DESIGN 78-39-54 E 128.28 FT TH S 81--20-44 E 447.24 FT TAP OF CURVE �-i STRIP LIGHTING 4 T-t 2 CONST. CONT. CONSTRUCTION NO (#) NUMBER coNTlNuous TO N: TH ELY ALG SD CURVE RAD OF 170 FT THRU C/A OF N.T.S. NOT To SCALE 2. HEATING VENTILATING & TO BE SELECTED .CONCAVE 15-51-28 ARC DIST OF 47.05 FT TH N 82-47-48 E 101.13 FT TO WLY ® CEILING DIFFUSER 3 Dlk( DRINKING FOUNTAIN O.C. ON CENTER AIR CONDITIONING DESIGN MGN OF POR OF SECTION 9 CONDEMNED IN SUPERIOR COURT CAUSE NO ® EXHAUST REGISTER O KEYNOTE DIA.(�) DIM. DIAMETER OFF. OFFICE DIMENSION O.F.L. OVERFLOW LEADER 646697 TH S 07-08-23 E 544.81 FT ALONG WESTERLY MARGIN TO A LN DR. DOOR O.P. OPERABLE 3. PLUMBING DESIGN N.A. 60 FT N OF & PLW ENGR B-LINE AS SHOWN ON SHEET 1 OF 7 FOR R/W 0 EF EXHAUST FAN Q DOOR NUMBER DET. D.S. DETAIL OPEN. OPENING DOWNSPOUT SR 99 SOUTH 118TH ST TO JUNCTION SSH 1-K APPROVED JULY 23, 1957 DTL DRAWING R PLATE 4. FIRE WATER SPRINKLER TH N 88-10-42 W 630.87 FT TAP 60 FT RGT OF ENGR STA B 548+00 SPRINKLER HEAD EXISTING DOOR P.L. PROPERTY LINE SYSTEM DESIGN N.A. SAID R/W PLANS TH N 79-41-19 W 359.21 FT TAP 70 FT RGT OF ENGR � EXH FH E.LFs. EXHAUST FAN EXT. INSUL. FINISH SYSTEM P'LAM PLASTIC LAMINATE STA H 551 +64.4 SD PT ALSO BEING PT OF CUVE CONCAVE TO NORTH RAD ® EXIT SIGN Q EXISTING RELITE EFHTW PLYWD. PLYWOOD DQSTING FULL HEIGHT WALL PNL PANEL PT BEARING N 10-18-41 E 748.51 FT TH NWLY ALG SD CURVE THRU ELEC. ELECTRICAL P&P PATCH AND PAINT 5. FIRE ALARM SYSTEM DESIGN TO BE SELECTED C A OF 30-03-04 ARC DISTANCE OF 392.59 FT TH N 41-57-30 E / � E DUPLEX OUTLET AT 15 A.F.F - - - ELEV. ENG. ELEVATION PTN. PARTITION ENGINEER 499.81 FT TH :N 15-27-21 E 75.56 FT TO POB E FOURPLEX OUTLET AT 15" A.F.F GRID LINES - COLUMN EQ. EQUAL R.B. RUBBER BASE =W DEDICATED DUPLEX OUTLET AT 15" A.F.F 101 ROOM NUMBER n EQUIP. E.W. E.W.C. EQUIPMENT R.D. ROOF DRAIN EYE WASH REC. RECESSED ELECTRIC WATER COOLER RECP. RECEPTACLE SEPARATE SUBMITTAL 10 LEGAL DESCRIPTION 7 w o DEDICATED FOURPLEX OUTLET AT 15" A.F.F � FLOOR MOUNTED OUTLET EXISTING WALL TO REMAIN EXIST. EXP. EXT. EXISTING RECP. REFLECTED EXPANSION RELIVE. REINFORCING EXTERIOR R.L. RAIN LEADER s 42" DUPLEX OUTLET AT 42" A.F.F _ � _ _ _ C - _ - _ - _ -I EXISTING WALL TO BE REMOVED FAC.F. F.A.R. FACTORY FINISH RM. ROOM FLOOR AREA RATIO SDG. SIDING COMPUTER\DATA OUTLET AT 15" A.F.F F.D. SHT. SHEET FLOOR DRAINF.D.c. FLOOR MOUNTED COMPUTER\DATA OUTLET -� �� "" F FIRE DEPARTMENT CONNECTION FOUNDATION S.F. SQUARE FEET S.O.G. SLAB ON GRADE Q DATA/PHONE OUTLET ,�$V;1 FO STUD & DRYWALL W/ SOUND BAIT INSULATION F.A. FIRE EXTINGUISHER SPEC. SPECIFICATION ER CABINET ;� �� Q DATA OUTLET CO CO PL°IA' 362S 125-18 @ 2'-0" O.C. WITH 3 1/2 " F.B. FINISHED FLOOR �, STANDARD TELEPHONE AT 15" A.F.F A �� F SOUND BLANKET INSULATION & 5/8" GWB F.H. FIN. FIRE HYDRANT STRUCT. STRUCTURAL FINISH' FLOOR MOUNTED TELEPHONE'L EACH SIDE UP TO CEILING. U.O.N. FL ST&VN STAIN AND VARNISH FLASHING FILE COPY FLR. FLOOR T. TOILET S „2M Sr -� LIGHT TOGGLE SWITCH AT 42" A.F.F Permit NO. ��� F.O.C. F.O.F. FACE OF CONCRETE TELE. TELEPHONE FACE OF FRAMING TEMP. TEMPERED -�-3 3-WAY LIGHT TOGGLE SWITCH Oaf 011 \ F.R.P. FT. FIBER REINFORCED PLASTIC T.I. TENANT IMPROVEMANT FEET T.O.P.TOP OF PARAPET „� IJILDI1 S „6M TYPICAL SPACING FOR ADJ. WALL OUTL Plan review approval is sub'ect to pp 1 errors and omissions. FrG. FOOTING T.W.C. TACKABLE WALL COVERING S „M Sr Approval of construction documents does not authorize GA. IYP. TYPICAL GAUGE 5 �s 99 -.... _-T.._ REVISIONS R RELOCATED �4 changes shall be made to the scope of work without prior approval of the violation of any opted code or ordinance. Racal of approved Field o d conditi na is 11�dged' SE[ ARATE I'� GALV. G.F.C.I. GL G.L.B. GALVANIZED U.O.N. UNLESS OTHERWISE NOTED CROUND FAULT CIRCUIT INTERRUPTER GLASS V.C.T. VINYL COMPOSITION TILE GLU-LAMINATED BEAM ��• ���� vERT. VERTICAL SITE N NEW Tukwila Building Division. PERMIT By, G.W.B. GYP. GYPSUM WALL BOARD GYPSUM V.W.C. VINYL WALL COVERING E EXISTING NOTE Revisions will require a new plan submittal Ia�E REQUIREDFOR: �� and may include additional plan review fees. 9 �� (� ©chanicaf H.B. HCP. W.C.WATER CLOSET NOSE BIB W.C. WALL COVERING HANDICAPED 599 Electrical My HDWR. HARDWARE WD. WOOD NOTE: THE ABOVE SYMBOLS ARE USED ON "T" SHEETS, REF. of Tukl& Plumbing HORIZ. H.P. HORIZONTAL WDW. WINDOW HIGH POINT W.H. WATER HEATER NORTH CONSULTANTS SYMBOLS FOR THEIR RESPECTIVE DWGS.DNIS Gas Piping H. HEIGHT W.R. WATER RESISTANT VICINITY MAP 8 LDING DIVISION SYMBOLS 4 -ABBREVIATIONS 1 1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO WASHINGTON STATE WAC CODE REFERENCE 2012 INTERNATIONAL BUILDING CODE (IBC) 51-50 ACCESSIBILITY REGULATIONS, THE 2012 INTERNATIONAL BUILDING, CODE (IBC) MECHANICAL AND ELECTRICAL CODES AND LOCAL CODES OR MOST WITH WASHINGTON STATE AMENDMENTS TENANT " RPI DIGITAL PRINTING 3325 SOUTH 116TH STREET s�4.32'29_"E CHAPTER 51-50 WAC (UBC 1988) - 21289' �." " RECENTLY ADOPTED EDITION OR ADOPTED AMENDMENTS TO THE WASHINGTON TUKWILA WASHINGTON 98168 ' W V �,� sZs'3s 54 E �2s.2s SOUTH 116TH STREEE T - STATE ENERGY CODE. 2. THE CONTRACTOR SHALL OBTAIN DESIGN/BUILD PERMITS AND REQUIRED JURISDICTION TUKWILA, WASHINGTON BRYAN CONSTABLE ^ � ib 6;;4. '�� Z APPROVALS. 3. TYPICAL DETAILS SHALL APPLY WHERE NO SPECIFIC DETAILS ARE GIVEN. °THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND CONDITIONS LAND USE ZONE MIC/L - (M-1) (MANUFACTURING INDUSTRIAL CENTER LIGHT) (VERIFY) SEISMIC DESIGN CATEGORY D VERIFY OWNER RREEF AMERICA REIT II CORP. MMMM7 WASHINGTON C/0 CBRE / .ASSET SERVICES PRIOR TO CONSTRUCTION. AVE S. SUITE 210 ® ® ® ' ® N7 1261' 5. ALL DIMENSIONS ARE TO TAKE PRECEDENCE OVER SCALE SHOWN ON PLANS, ELEVATIONS, SECTIONS, AND DETAILS. OPERABLE FROM. INSIDE BUILDING WITHOUT KEYS OR CONSTRUCTION TYPE III-B SPRINKLERED, (UBC Ill-N) UNLIMITED AREA KENT, WASHINGTON 98032 KENT, WASH2NDINGTON (253) 398-9006 FAX (253) 872-9884 ® 6. ALL EXIT DOORS TO BE PER ALTA SURVEY / SPECIAL KNOWLEDGE. OCCUPANCY GROUP B, F, S OCCUPANCY LOAD EXISTING AMBER STRATTON 7. OWNER AND CONTRACTOR TO DETERMINE EXTENT OF TENANT IMPROVEMENT / WORK AS RELATED TO SHELL CONSTRUCTIONWHERE NOT SPECIFICALLY DEFINED ON THE DRAWINGS. OFFICE - B t 16,867 S.F. 1/100 = 168 OCC MANUFACTURING - F f 25,596 S.F. 1/100 = 256 OCC CONTRACTOR GATEWAY CONSTRUCTION SERVICES 8. WALLS ARE TO BE FIRESTOPPED PER IBC SECTION 718. WAREHOUSE - S t 9,264 S.F. 1/500 = 19 OCC. 5602 SECOND AVE S. BUILDING 4 9. FIRE EXTINGUISHERS SHALL BE PROVIDED PER NFPA #10. PROVIDE (1) 2A:1OB:C FIRE EXTINGUISHER PER 3,000 S.F. OR 75' TRAVEL DISTANCE. EXTINGUISHERS 443 TOTAL SEATTLE, WASHINGTON 98108 621-9111 FAX 621-9113 3315 SOUTH 116TH ST. (206) (206) ±37,100 SF HAVING A GROSS WEIGHT NOT EXCEEDING 40 POUNDS SHALL BE INSTALLED SO NUMBER OF FLOORS 1 + 2ND LEVEL OFFICE BILL FOSTER / THAT THE TOP OF THE EXTINGUISHER IS NOT MORE THAN 60" (USE 48") BUILDING HEIGHT t 27'-0" HIGH a ABOVE THE FLOOR, PER IBC 906.9.1. & 2002 NFPA #10, 1.5.10. 10. ALL INTERIOR WALL COVERING MATERIALS SHALL BE FIRE RESISTIVE OR SHALL SITE AREA f 253,524 S.F. 5.82 ACRES ( ) ARCHITECT LPN ARCHITECTURE AND PLANNING BE TREATED- TO BE FIRE RESISTIVE, TO MEET IBC CHAPTER 6 REQUIREMENTS. FOR 2 BUILDINGS 3011 80TH AVE. S.E. DELIVER CERTIFICATE TO THE LOCAL FIRE DEPARTMENT. MERCER ISLAND, WASHINGTON 98040 4� �, ® 11. ALL INTERIOR WALLS ATTACHED TO SUSPENDED CEILING SYSTEMS TO MEET THE REQUIREMENTS OF IBC SECTION 1604 & 1607. GROSS BUILDING AREA t 50,395 S.F. EXISTING (ROOF DRIP LINE) (206) 230-6648 FAX (206) 230-6647 %�:� h w 12. WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED FOR SEISMIC FIRST FLOOR t 48,746 S.F. EXISTING ROYCE BERG CONDITIONS, IN BUILDINGS WHERE APPLICABLE. 13. PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS ARE TO BE FIRE * SECOND FLOOR t 2,981 S.F. EXISTING SERVICE COURT .g. • (3) GAS C1 STOPPED PER IBC SECTION 714. PARKING REQUIRED TUKWILA 3 METERS IZ -H ' 14. PENETRATIONS IN FLOORS AND CEILINGS REQUIRING PROTECTED OPENINGS ARE OFFICE t 16,867 SF 3/1000 = 51 STALLS ' S• TO BE FIRESTOPPED PER IBC SECTION 714. / GAS 15. WOOD USED IN PERMANENT PARTITIONS OF NONCOMBUSTIBLE CONSTRUCTION SHALL HAVE FIRE RETARDANT TREATMENT PER IBC SECTION 603.1. MANUFACTURING t 25,596 SF 1 /1000 = 26 STALLS WAREHOUSE f 9,264 SF 1 /2000 = 5 STALLS P 9 TO BE SUBMITTED TO ARCHITECT FOR REVIEW PRIOR TO CONSULTANTS 2 GAS METER a 16. ALL EQUALS 82 TOTAL / METER I CONSTRUCTION. 17. BID DESIGN WORK TO BE REVIEWED BY ARCHITECT PRIOR TO CONSTRUCTION. • 18. SUBMIT AS -BUILT DRAWINGS FOR GENERAL CONSTRUCTION, PLUMBING, PARKING ALLOCATION FOR BUILDING 3325 SOUTH 116TH (EXISTING) T 1 PROJECT DATA, VICINITY MAP, CODE DATA & SITE BUILDING 2 MECHANICAL, ELECTRICAL AND SPRINKLER TO ARCHITECT AT PROJECT . STANDARD = 120 STALLS 6g 3325 SOUTH 116TH ST. CLOSE-OUT. 19. EXIT CORRIDORS TO BE MAINTAINED DURING CONSTRUCTION OF EACH PHASE. • ACCESSIBLE = 6 STALLS 5 REQUIRED ( ) T-2 PLAN EXITING &OVERALL PLAN / A i50,380 SF 20. INSTALL SPRINKLERS ACCORDING TO DRAWINGS APPROVED BY LOCAL FIRE 126 STALLS PROVIDED FOR THIS BUILDING T-3 DEMO MARSHAL PLAN, CONSTRUCTION PLAN & CWJJ AREAS OF WORK ' 21. EXITS SHALL BE ILLUMINATED ANY TIME THE BUILDING IS OCCUPIED WITH LIGHT HAVING INTENSITY OF NOT LESS THAN 1 FOOT-CANDLE AT FLOOR LEVEL. ELuAN CITY OF TUKWILA 44.2' FIXTURES REQUIRED FOR EXIT ILLUMINATION SHALL BE SUPPLIED FROM FEB 0 9 2015 o 3 .8' ' SEPARATE SOURCES OF POWER AND BE PROVIDED WITH AN EMERGENCY SYSTEM PER IBC SECTION 1006. EMERGENCY SYSTEMS SHALL BE SUPPLIED DESCRIPTION OF WORK: PERMIT FROM STORAGE BATTERIES OR AN ON SITE GENERATOR IN ACCORDANCE WITH CENTER 00 ® I EXPAND PRODUCTION FLOW LINES FOR PRINTING STORAGE. REMOVE OLD • �`►. ® i® ® IBC SECTION 2702. 22. ELECTRIC RESISTANCE HEAT IS NOT ALLOWED. TENANT DEMISING WALL AND RELOCATE INTERIOR OVERHEAD DOOR. ` �i co 23. DIMENSIONS TO AND OF ELECTRICAL AND TELEPHONE OUTLETS INDICATES PROVIDE NEW ACCESS TO EXISTING OFFICE AREA. REMOVE END WALL R=748.51 �'�..� 00 A=30•o3'04' " �... '�• ^ MAXIMUM OF 6" FROM CENTERLINE OF ELECTRICAL OUTLET TO CENTERLINE OF TELEPHONE OUTLET. 24. DIMENSIONS SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE SECTIONS TO WIDEN MATERIAL AISLE. loop 0032 L=392.59 - - *DIMENSIONS OF NEW WORK TO FACE OF STUD Is _� " �� " �� " s7'19�E��18.63'`-' - " SR-� *DIMENSIONS OF EXISTING WORK TO FACE OF FINISH (NO ACCESS) NORTH *DIMENSIONS OF DEMO WORK TO FACE OF FINISH SITE PLAN 60' 9 GENERAL NOTES 6 CODE DATA 6 SHEET- INDEX 3- O © LU M cc z Q ~CIO O z a r co � a Occ Oa C� C* J Z 4 N he FU o CV)=111ARC HITECTU RE and PLANNING ROYCE A. BERG, PRINCIPAL 3011 80TH AVE SOUTHEAST MERCER ISLAND, WA. 98040 (206)230-6648 FAX 230-6647 2659 REGISTERED cHlTl:cr ROYCE A. BERG STATE OF. WASHING orl NO DESCRIPTION DATE DRAFT 1-28-15 PROGRESS PRINT 1-30-15 PERMIT SUBMITTAL 2-6-15 'DATA owAINED ON THESE PLANS OR HLECTR w FILES ARE PART OF THE CONSULTANTS INSTRUMENTS OF SIMM AND SHALL REMAIN THE PROPERTY OF THE CONSULTANT. SUCH DATA SHALL, NOT BE USED FOR ANY PURPOSE OTHER THAN FOR THE CONSTRUCTION OF THE REFERENCED PROJECT. ANY OTHER USE, REUSE OR MODIFICATION OF THE FILES WITHOUT THE CONSULTANT'S PRIOR WRITTEN CONSENT, WILL BE AT THE RECIPIENT'S SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO THE CONSULTANT.' PROJECT DATA, VICINITY MAP, CODE DATA & SITE PLAN PHASE II File:14005/T-1.dwg JOB NO.: 14005 SHEET NO: T-1 DATE: 1-21-15 DRAWN: SAM CHECK: RAB 1 EXIT 1 BCOeKE, I 4)asrm� \ II I wl / 44 -ES l �-7 i n/ 24 -s" -601 1 24, 3 A J• 0 L OCCUPANCY LOAD S.F. OCCUPANTS TRAVEL C.P.E.T. I DISTANCE OFFICE B 1 /100 S.F. t 16,867 SF = 168 300 SPRINKLERED 100' I MANUFACTURING F 1/100 S.F. t 25,596 SF = 256 250 SPRINKLERED 100' WAREHOUSE S 1 /500 S.F. t 9,264 SF = 19 250 SPRINKLERED 100' 443 MIN. 2 EXITS �; .,1:.... 09 COvo �������C ow0���, C , EXISTING 12ND FLOORI I PLAN II 11 10 9 8 7 " 6 5 4 3 2 1 12 - _ `6' 245 -0 _ / MAr&y/gt ASCfi 1�l I O24'-6" 24'-6" 24'-6" 24'-6" 24'-6" 24'-6" 24'-6" 24'-6" 24'-6" 24'-6" 19' 30, — cKEp I I I I I I I I I I BLOCK EXIT 1 EXIT , EXIT N� STq�GE / T \ / // \ y x ED I I BLOCKED ( BLOCKED ( BLOCKED BLOCKED I BLOCKED BLOCKED BLOCKED I BLOCKED BLOCKED BLOCKED PER �� ^� - x`\ \" •® II aM1,-02 ;.y:;'� � r iWC°MFVR,C RmR uR. .�w. exaI .0 R �RKWW Po4/.20 �I ^ IX uW6MAINTENANCE e 2u&uWT I�DONCAGE 36' � CAGS — — — --------�----- EZ MAT'L 7' MATERIAL AISLE 84 NDLING —--- zF �ya 1 _ _ 28'' J�T — — — —— — — — — EXISTING r- — — 111111-H L—S—R/lR—!]I —Q} — — —'--ti --fi —: — r — _-- s P—' , �� -- — — --I ----WAR—EH-OU—SE 2s EXISTING 58 50' --- II m00 0XISTjIVMANUFACTURING 1M02 AK r oKWES-02Rk Ig® / ( ' t •u« :..r :.wiz". 5>Srs"0 ,1^.' t „t - 3 , Cro ,5.. �'!_ \ 7,, , � .� '._. NPB-01 --• ' '' ��s� y; tYw,, .,Jj. -; � 9 u "t u' s a Bh'� :� '' s ,.'e`.z,auc Qc-„ \ c? —COWE A 20' I v'T L -FF6-08 d 3E ;- �' H ✓ I 3=139' � wEeoa s I s s a s _t _ _ - r� r k ( EXISTING wJU r y$c„�u �' }�ir,z.' v zr �� � �;a a7'� t - i� v 0. t d- E � { n= � � .�... I � I ELECT. XIST G l /. / IWj ii `• \ '` y— } 2 N'� ji. - • ' -� y 5+'. K''lFri r°'`X'\z i .gi e E8€S FAN—AF E � .. 13�1nL \ J L — — — — — I I r GR0 I I ---- - rl ),v "f`F. W„-02 YflRO CWT NERR)GWr � 2448a 55+,2 �. , YrH ]aYe 4' b NAWOR 3; 1. b'+ E is EXISTING 00 SMA-00 STH MANUFACTURING L .LS II( YM S Sx S SM 1 I W 1242 EMEN Jill� -¢ I L\J 51Q00_M L rTOT L®\ wa 52' o vw�- Rm 01A N-H z +E-U �tij �` ® I (n I ? w�.i1 5 R,� �� n- O �Hf '::y I # — _ we l z '�.' ,4-� wrJ min iws o�Rt'3wz Rwam ' 4w i.`` 4 x'- K_ Q Se 5 A sr su Bh08 JSs+2 I - — r— �— �o v ^ rEnro rl+rt uzmo cem uDRo crxr z wap f 2, R0 2, 60 2uRa — — :x,:, s� ux2 K z EXIT „ m / / \ \ I 1 ! „ / ®®®®® ®®®® tWR2R �� n•.: pr, I I I I _ 34' l/w \_ �'I���—� _�_2�J_ _ / / ----I —I ---I —I —I—--I —I ----x, —.• ss+—z —o-------I coz,Ra io Lhm iRi , ( I C`4 - — 7' MATERIAL AISLE 45' SLE18' I J I 741 I I --------------i---- 23-I----------- woo.------- — uu----- --E � I _ ,--.■ v� � d°�' ��a� v.h e f ® r r� � °, I I I ■ 1 XIST, ,� / J0i wa Jane JRKI2 ws Jaf,2 N 4 +' 't �`- a�; T _,dtlat' . P., '�;;` ®� ®® O O OFFIC NG l _ —� AU �9 ®I ! 8 - - I I EXISTING — 38 �� r r, ®® �^ I I o COLUMN TYP. o o s I I h — J . ,: ' �' ®® I I EXISTING I "' H o , _ w ' i I Dur-oe z nw, z4.w ! by ' P'l ®® W (/) vi :m I I W s ass, l BW-04 �.. f� t .ry ' 3r� ,�� COMCM2a- DOUBLE STACK 1 `z? li .. O O O O .EXISTING I 'x .T� O O LX I i co r<as,'Y o o p p SERVER ROOM 0 O I N EXISTI I 15. 6' 77> I I MEN ----------- -- ----- 25r5,, " ,p �� ,25V5,,, �1 / o ' �r. r\r\ /-'t j� y I\r\ /, M I I ��' Ioil -------------� ---- — Su r 7,0. ,, r Ex�T``���,� �' � su ,{ � � ar; � x I r � � w � � I �, , xz� C.v"4�ar•� as% I �C. I I I T 25�, su /��� ;i� � .�r.� � "K rc+ _ fF k�'� r F #5> `4 ^c _• I / zs+s, su t4,'� fFm o-..,� * ( 6 L 25.J, �„ / �RJaw »i�rr.1T� �, EXISTING 34' — ; ■ -t _ — I 1 2 J/ 0 I _ — - . .. — 8 J BREAK — — I I o l / -- 1 lj 4p' 15 4 �6" - �- — — � � � a YRiROCAar � � 1 — — — — — — -. I � in 24+80 14 EXIT �--------------�--------------�-------------■�---------------�------------�----- EXIT EXIT EXIT t33'- 1 , 13 10 7/g" 245'-0" 1 1 11 SCHEMATIC EQUIPMENT LAYOUT PER - 1 THE PINNACLE CONSULTING GROUP, INC. DRAWINGS RECEIVED CITY OF TUKWILA FEB. 0 9 2015 PERMIT CENTER A &A - EXISTING SPRINKLER EXISTING 'IRE ALARM u C E EXITING 6 OVERALL PLAN 11/16`1 1 a O 0 d ~ 4CI W W Z o Q ILL. yr 1�- 33r. z 2 Q W 0 R:: Q z ro ■B� a CV he • • ROYCE A. BERG, PRINCIPAL 3011 80TH "E SOUTHEAST MERCER ISLAND, WA. 98040 (206)230-6648 FAX 230-6647 2659 EGISTERED ITECT RYCEA. BEG STATE OF NfASihI11GT N NO DESCRIPTION DATE DRAB' 1-28-15 PROGRESS PRINT 1-30-15 PERMIT SUBMITTAL 2-6-15 "DATA CONTAINm ON THESE PLANS OR EtECfIt m FILES ARE PARr OF THE CONSULTANT'S INSWMENIS OF SERVICE AND SHALL ROM, THE PROPERTY OF THE CONSULTANT. SUCH DATA SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN FOR THE CONSnWCT10N OF THE REFERENCED PROJECT. ANY OTHER USE, REUSE OR MODIFICATION OF THE FILES WITHOUT THE CONSULTANT'S PRIOR WRITTEN CONSENT, WILL BE AT THE RECIPIENT'S SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO THE CONSULTANT.' EXITING PLAN & OVERALL PLAN PHASE II File: 14005/T-2.dwg JOB NO.: 14005 SHEET NO: T-2 DATE: 1-21-15 DRAWN: SAM CHECK: RAB m s 0 H REPAIR/REPLACE PIN R-21 INSULATION WI FR-25 VAPOR BARRI MATCH EXISTING 2" R-10 XPS RIGID INSULATION WITH 250S125-18 FURRIP WITH 5/8" GWB ANC R-13 INSULATION GWB TO 8' BETWEEN OPENINGS EXISTING OVERHEAD DOORS HEIGHTS VARIES 10' & 14' PERIMETER CONCRETE WALL 13/8111 3 1 i 18 l7 ._�� a CT�O l CFjLIN G pLq Af r < « �' ERISTING %l BEAK rr oc—� EXI o C ' `r WNi G £XISTING Ft QR�R£Stk , �r N � o SAND TAN nR�£ oNS % r, MO £X/S OXISTINC £XjST/NG / G r `l CC y£I GyT WAL N I FFIC£ MEN M£N r ir' 1 r « r rr £ O£XisTi op£NING NG OFFICECSNTERi XIST/N� £E D! OFFICE 4 REMOV Co�' EXISTi /R£S�L CAAR� H£` tUMN l yp q £C(lR f D 1 SUOR£sCE GHTS To £ F1 S REQUIREpRS £D /N p pp TUBES AMAIN A 2 , 4 ..6„ _ REMov UCTIoN AR,,AMATC� 18 24 ;s„ -_ ' UNDER c WALL PART �, E/uNIg /TION S 17 24 6� / _ �_ �MCAT£D 3, 4 E WED Cx8 DOOR �s r47:.0. �EC yA pA D ,5 2.1> �6jtp> 14 24 =6h % '£xISON F(UOR£ C�/GHTS TC USED IN %Dt C FS rOOMq R£PLgC `^-,- TIoN ARe4ATCH COLOR STEEL STUDS WALL FLOOR FRAMING BEYOND GWB AND FRAMING -1F-#2 HEADER '.T." POST WITH SIMPSON AILING PER IBC kMB & HEADER TRIM NEW OPENING _.. ,.� v a GRID LINE 13-16 • REMOVE SECTION OF FULL HEIGHT WALLS. • RELOCATE 12'x10' INSULATED HIGH DOOR LIFT TO EXISTING OPENING AT GRID LINE 16. • REMOVE WALL BUMP OUTS TO WIDEN CORRIDOR AT GRID LINE 4C. • CLEAR AND RESEAL CONCRETE FLOORS. DEMOLITION NOTES, O REMOVE AND DISPOSE OF WALLS, RELOCATE OR TERMINATE VOICE, DATA, AND POWER AS REQUIRED BY CODE. O2 REMOVE AND STORE EXISTING DOOR WITH HARDWARE AND FRAME FOR POSSIBLE RELOCATION. O3 REMOVE AND STORE EXISTING RELITE AND FRAME FOR POSSIBLE RELOCATION. �4> REMOVE AND DISPOSE OF PORTION OF EXISTING WALL SYSTEM TO ALLOW FOR NEW PASS THRU OPENING; COORDINATE REQUIRED ROUGH OPENING SIZE PRIOR TO DEMOLITION. 5O MECHANICALLY REMOVE EXISTING FLOORING AND GLUE FOR A CLEAN CONCRETE SUBSTRATE. i I I l EXISTING 1 2ND FLOOR PLAN }33'- 1, '— 10 7/8 I ----------- ----J EXIT INSTALL RUBBER TRANSITION STRIP AT EDGE OF CARPET OW1 I I d' N XISTING BREAK I EXISTING I 10 OFFICE j �W 00 W I co I I I _. I I ! 40 I I Lo 1 CITY OF TUKWIL� FEB 20154 ! PERMIT CENTE� � NORTH 0 W w z F' 0 LI.y c I=- , CID Z F � _ a 0 U = 0J _ Z cry► to z CV he C2 H ARC HITECTU RE PLANNING ROYCE A. BERG, PRINCIPAL 3011 80TH AVE SOUTHEAST MERCER ISLAND, WA. 98040 (206)230-6648 FAX 230-6647 2659 EGISTERED CHITECT R YCE . B G STATE OF WASHING N NO DESCRIPTION DATE DRAFT 1-28-15 PROGRESS PRINT 1-30-15 PERMIT SUBMITTAL 2-6-15 'DATA CONTAINED ON THESE PLANS OR ELECTRONIC Fum ARE PART OF THE CONSULTANT'S WRUMENTS OF SERVICE AND SWILL REMADI THE PROPERTY OF THE CONSULTANT. SUCH DATA SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN FOR THE CONSTRUCTION OF THE REFERENCED PROJECT. ANY OTHER USE, REUSE OR MODIFICATION OF THE FILES WITHOUT THE CONSULTANT'S PRIOR WRITTEN CONSENT, WILL BE AT THE RECIPIENT'S SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO THE CONSULTANT.' DEMO, CONSTRUCTION & CEILING PLANS PHASE II File: 14005/T-1.dwg JOB NO.: 14005 SHEET NO: DATE: 1-21-15 T-3. SAM DRAWN: CHECK: RAB