Loading...
HomeMy WebLinkAboutPermit D15-0043 - SEATTLE GOURMET FOOD - DOCKLEVELERSSEATTLE GOURMET FOODS 18260 SEGALE PARK B DR D15-0043 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: h"p://www.TukwilaWA.Rov DEVELOPMENT PERMIT Parcel No: 3523049119 Permit Number: D15-0043 Address: 18260 SEGALE PARK B DR Issue Date: 2/25/2015 Permit Expires On: 8/24/2015 Project Name: SEATTLE GOURMET FOOD Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028, TUKWILA, WA, 98138 Contact Person: Name: STEVE NELSON Phone: (206) 575-2000 Address: PO BOX 88028, TUKWILA, WA, 98138 Contractor: Name: SEGALE PROPERTIES LLC Phone: (206) 575-2000 Address: PO BOX 88028, TUKWILA, WA, 98138 License No: SEGALPL902CQ Expiration Date: 4/1/2016 Lender: Name: SELF -FUNDED SEGALE PROPERTIES Address: , , , DESCRIPTION OF WORK: INSTALL THREE DOCKLEVELERS AT EXISTING OVERHEAD DOOR OPENINGS. Project Valuation: $17,014.00 Fees Collected: $757.78 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Occupancy per IBC: Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: HIGHLINE Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: 2012 National Electrical Code: 2014 2012 WA Cities Electrical Code: 2014 2012 WAC 296-46B: 2014 2012 WA State Energy Code: 2012 2012 Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: Date: I hearby certify that I have read and examined t . permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Sign Prin atur G" Date: Z zs� 1S t Name: C4-1� )Z ✓le6OfAs This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 0301 CONCRETE SLAB 0200 FOUNDATION WALL 4046 SI-EPDXY/EXP CONC CITY OF TUKWILA Community Development Department ' Public Works Department • Permit Center 6300 Southcenter Blvd., Suite 100 Tuk►vila, WA 98188 hitp://www.TukwilaWA.jzov Building Permit No. D Project No. _ Date Application Accepted: G 7 1-5 Date Application Expires: use CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 352304 9119 Site Address: 18260 SEGALE PARK DR B Suite Number: Floor: Tenant Name: SEATTLE GOURMET FOOD New Tenant: m .....Yes [:]..No PROPERTY OWNER Name: SEGALE PROPERTIES Address: PO BOX 88028 City: TUKWILA State: WA Zip:98188 CONTACT PERSON — person receiving all project communication Name: STEVE NELSON Address: PO BOX 88028 City: TUKWILA State: WA Zip: 98138 Phone: (206) 575-2000 Fax: (206) 575-1837 Email: SNELSON@SEGALEPROPERTIES.COM GENERAL CONTRACTOR INFORMATION Company Name: SEGALE PROPERTIES Address: PO BOX 88028 City: TUKWILA State: WA Zip: 98138 Phone: (206) 575-2000 Fax: (206) 575-1837 Contr Reg No.: SEGALPL902CQ Exp Date: 04/03/2016 Tukwila Business License No.: BUS-0101320 ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Rack Design & Engineering Co. Engineer Name: Garrick Ohanian Address: 412 West Broadway Suite 204 City: Glendale State: CA Zip: 91204 Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: SELF FUNDED Address: City: State: Zip: HAApplicationsUorms-Applications On Line\2011 ApplicationsTermit Application Revised - 8.9-1 I.docz Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMAT101. — 206-431-3670 Valuation of Project (contractor's bid price): $ 17,014 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): INSTALL THREE DOCKLEVELERS AT EXISTING OVERHEAD DOOR OPENINGS. Will there be new rack storage? ❑..... Yes 6fl.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below :1 Existing Interior.Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I' Floor 39,224 V-B S-1 2"d Floor 3'd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑....... Yes ❑....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: © ....... Sprinklers elf ....... Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑....... Yes IZI .......No If "yes, attach list of materials and storage locations on a separate 8-112"x I " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Form -Applications On Line\2011 ApplicationsTermit Application Revised-8-9-11.docx Revised: August 2011 Page 2 of 4 bh PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A Signature:. Date: 02/17/2015 Print Name: STEVEN R. NELSON Day Telephone: (206) 575-2000 Mailing Address: PO BOX 88028 TUKWILA WA 98138 City State Zip H:\Applicationsfforms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 Ldocx Revised: August 2011 bh Page 4 of 4 DESCRIPTIONS PermitTRAK 1 $757.78 D15-0043 Address: 18260 SEGALE PARK B DR Apn: 3523049119 $757.78 DEVELOPMENT $735.62 PERMIT FEE R000.322.100.00.00 0.00 $443.10 PLAN CHECK FEE R000.345.830.00.00 0.00 $288.02 WASHINGTON STATE SURCHARGE 13640.237.114 0.00 $4.50 TECHNOLOGY FEE $22.16 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R4561 R000.322.900.04.00 0.00 $22.16 $757.78 Date Paid: Tuesday, February 17, 2015 Paid By: SEGALE PROPERTIES Pay Method: CHECK 8327 Printed: Tuesday, February 17, 2015 2:42 PM 1 of 1 RWSYSTEMS IN PECTION RECORD Retain a copy with permit (-5-CO MPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36774 Permit Inspection Request Line (206) 438-9350 P , t , �. _0 0 T4�ffel C70 U'rct-&� 113ate a a - Typ-6Xq'c1` ?� �d�Fess: te- CalleoV pecial instrucVbns. rT Date Wanted: a.m. pm. Requetter: . M V-r y Phone NO: I Z-O(Z' REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. &f I 94: INSPECTION RECORD OZ11 7 6with permit 4 1 Retain a copy 11 "KtTION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project,— Type of In Af1dress: Date Called: to ).ro o gair ICK .1 Special Instructie"t, A -AA Date �WfjeT' a.m. -3 - 2A (J—p.m. Requester', A" � Phone No- 2,5 a- — ( —.. Z-0 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cali to schedule reinspection. L04" INSPECTION RECORD (131 Retain a copy with permit D(5-- W INSVE-CTION O. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr9ject'. ,, — ------ --- > (5�?' ry Gv V""ffl- � Type f Inspection: L . 4 dress: yr)-x E��(e 16U'k'6 pl. Date Called Special Instructions. A-.,q Date Wanted: a.m. -Z 1� � q — 0' p.m Req es er: W1 mea�ne No� I ?-� - REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection, PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0043 DATE: 02/17/15 PROJECT NAME: SEATTLE GOURMET FOODS SITE ADDRESS: 18260 SEGALE PARK DR B X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter #, TTT � TTI�iiT ATTCI_ Buil+ding Division Ntqu 1 K Public Works PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: Revision # after Permit Issued Fire Prevention4 Structural ❑ Planning Division IN Permit Coordinator 10 DATE: 02/19/15 Structural Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/19/15 Approved ❑ Approved with Conditions i Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 1211812013 SEGALE PROPERITIES LLC Page 1 of 2 Home i.nieio en .lispafiol Contact Safety Washington State department of Labor & Industries SEGALE PROPERITIES LLC Owner or tradesperson SEGALE, MARIO A Principals SEGALE, MARIO A, PARTNER/MEMBER SEGALE, MARIO A, AGENT Doing business as SEGALE PROPERITIES LLC WA UBI No. 602 023 533 License Search L&I ICI A-% fndex Help boy Se<-ure L&I Claims & Insurance Workplace Rights Trades & Licensing PO BOX 88028 TUKWILA, WA 98138-2028 206-575-2000 KING County Business type Limited Liability Company Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ....................................................................... Meets current requirements. License specialties GENERAL License no. SEGALPL902CQ Effective — expiration 02/18/2010— 04/03/2016 Bond SAFECO INS CO OF AM $12,000.00 Bond account no. 6115146 Received by L&I Effective date 03/28/2002 02/18/2010 Expiration date Until Canceled Insurance ........... .... ............ Alaska National Insurance Co $1,000,000.00 Policy no. 14DLS31006 Received by L&I Effective date 03/28/2014 04/01 /2014 Expiration date 04/01 /2016 Insurance history Savings ...................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts .... _................. _............... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602023533&LIC=SEGALPL902CQ&SAW= 02/25/2015 MERIWETHER . . IEX,*i, ES 1 15 UILDIWs WALL. I, C. 0r__< j_FY9 ,ER PIT - PLAN _VIELL) 6TR TUIR ILNOIES' D CONCRETE`. TO ATTAIN A 28 DAY COMPRES51VE. STRENGTH OF 2J E'IIv CRCa,Ir"r &HALL CONFORM To ASTf'1 A-615 GRADE 46'01` 60, 3) FINAL CONCRETE '6.4WJ= kCES 61,4ALL HAVE A FINISli­l 5IM4 AR TO EXMTiN C, 4J PROVIDE A 3" MIN. COVER TO ALL REBAlF 5) FORIDIw CE.N;OICN'6, iGURD t I sl,E a ANC) It*I aERT 54AVPEF SEE MANU11,B,C.70AV6 DRAIONG AND SIPECIFICATIONf;, W NIOL 5PECIIA'L 1NSFECTICN IS RE0U?,fZE0 i TO 20 AMP BREAKER T I LINE aFXO DOCKLEVELER STANDARDIZED PIT DETAILS I NEUTRAL STRAIGHT PIT I L PUSH GROUND BUTTON FOR SOLAR APPLICATIONS SEE ,I APPROVAL DRAWINGS FOR ALL CONTROL CONDUIT INFORMATION. RECEPTACLE`- / STATION 3/4" CONDUIT, WITH 115V PLUG RECEPTACLE (NEMA 5-15R) WIRED AS SHOWN FOR o- PLUG IN CONNECTION. TO 20 AMP BREAKER, LOCATION TO BE FLUSH OR 115VAC, 10 POWER RECESSED MOUNTED ON SUPPLY CENTER (SIZE OF CONDUIT FAN AND WIRE GAUGE MAY DOCKLEVELER ;I MOTOR VARY WITH LOCAL CODES.) CONTROLBOX 115V, Single 4 Phase, 60 Hz ATTACH TO STUB " CONDUIT 6" STUB OUT II BRANCH "TEE" 90° 90° 12' \ r aaCse \ \ 14" PIT "All \ to Angle 2 LAMINATED BUMPERS FURNISHED BY KELLEY 5563 R4 JULY 2010 «H » 90° «p f J• DOCK HEIGHT r gEll 34" 8-3/4 SEE NOTE 1 BUMPER MOUNTING ANGLE NOTE 1: IF A STAR TRUK STOP IS TO BE INSTALLED AND THE DRIVEWAY IS SUSCEPTIBLE TO FROST, PLACEA STYRAFOAM BLOCK IN THE CONCRETE IN THIS AREA. THIS WILL PREVENT DAMAGE TO THE STAR TRUK STOP WHEN DRIVEWAY RISES. «G„ 2 aFXO DOCKLEVELER STANDARDIZED PIT DETAILS - STRAIGHT PIT aFX DOCKLEVELER_______.. CONTROL BOX l CONTROL BOX STAR CONTROL BOX 48' 48" 17 LOCATION FOR aFXO DOCKLEVELER LOCATION FOR SINGLE CONTROL BOX AND STAR® CONTROLS FOR DOCKLEVELER OR STAR® ANCHOR LAYOUT FOR CURB ANGLE —►I 3„ I~ 12',+--r I I.-- 12'L I14-- 12%-+ 13" 14— —►.I 3" I 4— —►III 1/4" CONCRETE ANCHORS, 1/2" DIA., 6" LONG, LOCATED AS SHOWN NOMINAL ` DOCKLEVELER 6' x 6' ,, . 6' x 8' `' 6' x 10' 6.5' x 6' 6.5' x 8' 65x 10' 7' x 6' 7' x 8' 7' x 10' SIZE PIT DIM. °r 63 " 87' 111" 63" 87" 111" 63" 87" 111" LENGTH "A" :I PIT DIM. 74" `= 74" 74" 80" 80" 80" 85" 85" 85" WIDTH "B"' PITJ DEPTH C,; 19-1/2" i 19-1/2 ', 23-1/2" 19-1/2" 19-1/2" 23-1/2" 19-1/2" 19-1/2" 23-1/2" Rear PIT DEPTH DI . 20 %' 20" I 24" 20" 20" 24" 20" 20" 24„ Front CURB ANGLE DIM. 80' 80" ) 80" 86" 86" 86" 91" 91" 91" „E„ Front/Rear CURB ANGLE DIM. 60' I 84' 108" 60" 84" 108" 60" 84" 108" Side F CURB DIM. ANGLE 21" I?. 21" % 21" 21" 21" 21" 21" 21" 21" Bumper G„ CURB ANGLE DIM' 17" 17' 21" 17" 17" 21" 17" 17" 21" Bumper .I %3 NOTE: See Kelley Drawing No. 10-740 for Cantilever Pit Detail. See Kelley Product Manual for Wiring Diagrams. 3 5563 R4 JULY 2010 TOP VIEW, STAR° CONDUIT RUN LOCATION DETAILS NOTE: ALL MOTOR POWER WIRES OR OTHER HIGH VOLTAGE WIRES SHOULD BE RUN IN A SEPARATE CONDUIT FROM ALL LOW VOLTAGE CONTROL CIRCUIT WIRING. THROUGH WALL TO BOX FOR SIGNAL LIGHT 1/2" CONDUIT 3-13/16"J TO POWER SUPPLY 1/2" CONDUIT ,I 11-3/8" w, 6-3/8" CONTROL BOX NOTE: SIGNAL LIGHT MUST BE ON TRUCK DRIVER'S SIDE OF DOOR OPENING. h V _43" Dockleveler Pit 3/4" CONDUIT (NOT REQUIRED FOR STAR 1 OR STAR 1 with TRUK ALERT) EXIT CONDUIT INSIDE BUILDING NEAR WALL UNDER CONTROL BOX. i *ADDITIONAL CONDUIT REQUIREMENTS *ADDITIONAL CONDUIT REQUIREMENTS FOR OPTIONAL FLOOD PACKAGE — STAR 4 FOR OPTIONAL LIP LIMIT SWITCH — STAR 4 EXIT CONDUIT INSIDE.BUILDING NEAR WALLJJNt)E CONTROL BOX. 16" j P 1/2" CONDUIT FOR HYDRAULIC HOSES USE \ 14' 2" CONDUIT (DRAIN WASTE f f \ OR VENT PVC PIPE WITH 45° LONG SWEEP ELBOW) \ 15" „I j 42" 3 EXIT CON DU IT AT ANGLETODOCK / /41 / FACE 3" ABOVE DRIVE r *Requires both the standard conduit run and the additional conduit for the option. ( Dockleveler Pit Dockleveler Pit ECEIVED CITY OF TUKWIIILA 1612 Hutton Drive, Suite 140 • Carrollton, Texas 75006 KELLE ® Phone: (800) 558-6060 • Fax:(972)389-4752 FEB 17 2015 5563 R4 JULY 2010 4 PERMIT CENTER 0 I i 0 00 W W D (Y O 0 00 00 f W r` // 01 00 L1_ W J NQ, :D O 'D IZ JC) O Z O Y N * D` O X ry a d* I n * o 0 J QUo J W O U D > O W Elf o WI Q F Y I LLJ *_j O l N d PQ z a U a U1)(LU Od DW Cn m W LLJ o o w J Q ra0 z Ln O N m m 0 e m e z o o 5 Qo ► y L-I_ C!) ch ao o m O W Y ..II F IIW 0- a LLJI I— o -J o I- 0U o Q Ld O (0 3 wW W Q PROJECT NUMBER: X DRAWING NUMBER: 2 SHEET: 2 OF: 2