Loading...
HomeMy WebLinkAboutPermit D15-0049 - LEGO - DEMOLITION AND TENANT IMPROVEMENTLEGO 837 SOUTHCENTER MALL D15-0049 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT Parcel No: 9202470010 Permit Number: D15-0049 Address: 837 SOUTHCENTER MALL Issue Date: 3/26/2015 Permit Expires On: 9/22/2015 Project Name: LEGO Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940, CARLSBAD, WA, 92013 Contact Person: Name: TERRY MUNDEN Address: 11229 SE 286 ST, AUBURN, WA, 98092 Contractor: Name: FISHER DEVELOPMENT INC Address: 601 CALIFORNIA ST #300, SAN FRANCISCO, CA, 94108 License No: FISHED1141PT Lender: Name: LEGO BRAND RETAIL Address: 555 TAYLOR RD PO BOX 1600, ENFIELD, CN, 06083 DESCRIPTION OF WORK: Phone: (253) 670-2528 Phone: (415) 468-1717 Expiration Date: DEMOLITION OF EXISTING TENANT SPACE AND THEN COMPETE REBUILD FOR NEW TENANT, LEGO Project Valuation: $275,000.00 Fees Collected: $5,102.98 Type of Fire Protection: Sprinklers: YES Fire Alarm: NO Type of Construction: IIB Occupancy per IBC: M Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Chan neIization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No r' , Permit Center Authorized Signature: �/ ` Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of /ermit. k. I am authorized to sign and obtain this development permit and agree to the con�iions attached to this Signature: Print Name: Date: 3 L G S This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 7: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 8: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 9: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 10: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 11: Special inspection for sprayed fire-resistant materials applied to structural elements and decks is required. Special inspections shall be based on the fire -resistance design as designated in the approved construction documents. 12: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 13: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 14: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 15: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4-inches shall be maintained above the controls with the strapping. 16: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 17: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 18: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 19: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 38: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 20: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 21: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 22: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 23: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 24: Maintain fire extinguisher coverage throughout. 25: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 26: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 27: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 28: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 29: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 33: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 31: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 30: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 34: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 36: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 37: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 39: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 42: Post address on storefront per approved Westfield standards. 32: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 40: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 41: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at(206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH & GYPSUM 0406 SUSPENDED CEILING CITY OF 7T)KMLA Community Development Department Public Works Department i Permit Center 6300 Southeenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA..P,ov SITE LOCATION Building Permit No. 0 1 `j - " Project No. Date Application Accepted- s, Date Application Expires: �—�/ use CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" King Co Assessor's Tax No.: Site Address:.SWT1,jGa-AA -e. 42ALL 93750grhC.wmom "�m�teNumber: )_ 8150 Floor: Tenant Name: L co Si r .98'1! New Tenant. [51 Yes []..No PROPERTY OWNER Name: (o 63% c 113r 0 L L C. Address: 11401 1G ' W 1 LS,H I'44 L VD City: Z,a State: C R Zip vS A1OOa? CONTACT PERSON — person receiving all project communication Name: —r S R A Nt v N,Dv-7tJ Address: 1 2 2 city: 1+011V-eN State: W4 Zip:9, 90 Phone: 016 3 - 670 ,'Wax: Email: r IMP CAI ISNt9X Mok,' . 0201" GENERAL CONTRACTOR INFORMATION Company Name- F1- tTit C Address - City: VN r=Aftl. State: C iq Zlp:9,11 o S Phone: y 15 _',a8, _3 J LO Fax: Contr Reg No.: Exp Date: it Tukwila Business License No.: ARCHITECT OF RECORD Company Name: ,10-T 46 (t6 l K/ '0CN 1 t Architect Name: hVL .I>04.11 Address: I X7 . City: S �G a State: Zip: y Phone: Fax: Email: ENGINEER OF RECORD Company Name: ' O A) t1 Engineer Name: Address: • 8'If rhtDr7L�' r i City: �'11O.OLo"Td �Jlli State: G i Zip. cjS Phone: Fax: [!mail: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 1.9.27.095) Name: r Address: City: �N F/ cam. o State: CT Zip: 060 H:\Applications\Forrm-Applications On Line\2011 ApplieationsTer mt Application Revised - 8.9.11.docx Revised: August 2011 bh Page I of 4 R 3 BUILDING PERMIT EVORMAT ON - 206-43I-3670 Valuation of Project (contractor's bid price): $ Q 7S- D 0 D. 00 Existing Building Valuation: $ Describe the scopeF of work (please provide detailed information): _ �$/b TJ 7-&—W& St��C a /�y -O 7H ` N Fox vow Will there be new rack storage? 9.... Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 15' Floor 2 Floor Existing Interior Remodel a5c• Addition to Existing Structure New Type of Construction per IBC � Type of Occupancy per IBC � 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION• Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than IS inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑....... Yes El ....... No If "yes", explain: FIRE PROTECTIONIHAZARDOUS MATERIALS: a....... Sprinklers K ....... Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ....... Yes (9.. No If ` yes , attach list of materials and storage locations on a separate 8-112"x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Wpplicati0mT0rmt-Appiicatiwts On LineV.011 AppiicationalPermit Application Revised - 8-9.1 Ld. bnhea. August 2011 Page 2 of 4 PUBLIC WORKS PERAUT INFOIt�-ATION - 206433-0179 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑ ... Water District # 125 ❑... Valley View ❑ ... Sewer Availability Provided ❑ .. Highline ❑ .. Renton ❑ .. Renton ❑ .. Seattle Septic Svstem• ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Stone Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ .. Right-of-way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way Non Right-of-way ❑ ❑ ...Total Cut cubic yards ❑ .. Work in Flood Zone ❑ ...Total Fill cubic yards ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer El.. Abandon Septic Tank ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ ... Fron a Improvements ❑ •• Trench n h Excavation � P ❑ .. Pavement Cut ❑ ...Traffic Control ❑ ••Trench Excavation ❑ .. Looped Fire Line ❑ .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection " Irrigation " Domestic Water " ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size.. WO # ❑ ...Water Only Meter Size............ WO # ❑...Deduct Water Meter Size ❑ ...Sewer Main Extension.............Public ❑ Private ❑ ❑ ...Water Main Extension.............Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line _ ❑ ...Water ❑ ...Sewer Monthly Service Billing to: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: Mailing Address: City State Zip Water Meter Refimd/Billinw, Name: Day Telephone: Mailing Address: arty State zip ••. ,•,vv��•••�u ••• �•o-•,.pp..ww,o vn �i���i i APPuca[rons MMIt npplIMMn Revised . 3-9-11.docx Revisedeh' August 2011Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER UTAO D )E Signature: Date: a7 'a G. A .5 Print Name: "]r"E,.`/l rQ 11 AL My A/ Q & % Day Telephone: � S 3 ' 6 70 ' p7 S -f( Mailing Address: 1 2 2 �j S.r' .'� g'�, S r AV A 0m) PO - 4 to 9 2 City State Zip FL%Appliwtions\Forms-Applicatiom On Line\2011 ApplieationsTennit Application Revised - 8-9.1l.doex Revised: August 2011 h� Page 4 of 4 Date Paid: Monday, May 18, 2015 Paid By: TERRY MUNDEN Pay Method: CREDIT CARD 03048G Printed: Monday, May 18, 2015 10:41 AM 1 of 1 RWSYSTEMS DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $3,153.56 D15-0049 Address: 837 SOUTHCENTER MALL Apn: 9202470010 $3,153.56 DEVELOPMENT $3,003.60 PERMIT FEE R000.322.100.00.00 0.00 $2,999.10 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $149.96 TECHNOLOGY FEE TOTAL'+ '4•1: R000.322.900.04.00 0.00 $149.96 Date Paid: Thursday, March 26, 2015 Paid By: FISHER DEVELOPMENT INC Pay Method: CHECK 171421 Printed: Thursday, March 26, 2015 9:10 AM 1 of 1 IIff RlSY57EM5 Date Paid: Thursday, February 26, 2015 Paid By: KENNY MUNDEN FISHER DEVELOPMEN Pay Method: CREDIT CARD 02668G Printed: Thursday, February 26, 2015 1:34 PM 1 of 1 RWSYSTEMS INSPECTION RECORD (N Retain a copy with permit I Pa: toY PE ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj ct: Type o rtsp�ection* ess: `� a Date Called Special In Date Ted.,( a.m. Requester: Phone No: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. gall to schedule reinspection. INSPECTION RECORD N Retain a copy with permit (S 4(j q5 INSPENQfl NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project: TypeIgspgctio(� A dress: .,' Date Called -Fill Spe ial instructions: 4M Date Wanted: a.m. — I _— p.m. Req ester: Phone No: ElApproved per applicable codes. corrections required prior to approval. u Inspector: J Date y� 1 .r f REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cat( to schedule reinspection. INSPECTION RECORD Retain a copy with permit 9t"f-00 IN CTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect: Type f irnspectiGn: "'0 -1= k mul Address. ` Date Called: a 1V�"� Special Instructions: Date Wante a.m. ®." p.m. 4"1 Re u ter: Phone o 7-y- 6 70 Z-5 za Inspector: lr--C� I Dater - ( cr-)— ( REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Calt to schedule reinspection. tt!7 INSPECTION RECORD EC4))-- ----------- 71 Retain a copy with permit IN CTION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 0 Vne a nspectiori ov-(A-d ea Gel 119- ress:\,J Date CaII4(d--:-- Special Instructions: S0 OGI0 0 141 + Date W nted.- a.m. p.m. Requester'A P one o: SF3 G 7 0 E] REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100, Galt to schedule reinspection. INSPECTION RECORD q Retain a copy with permit LP(- 5 0011, I INSPICTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 prolect'. L"o Type Jinspection, k rrq Adre. 5o,.k** Cfr ate Called: Special Instructions, Date Wf Lea.m. p.m. Requester: ne No: Phone 1?4� 6 70 I inspector: F-P, — r-5,— I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Gait to schedule reinspection. re INSPECTION RECORD . ... .... Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: rLq .0 Type ofjwpection, L� cm rc-g Xd`dres 9. rIDate Called: pecial Instructions. Special Date Want a,rn. -5 - (3 - (J- p.m. Requester: h �on e 4w 2, 1:1 Approved per applicable codes. n Corrections required prior to approval. Inspector: Date*S-- 3 - i .-- ES- REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD I Retain a copy with permit D (5-- 00 �q INMCTION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwiia. WA 98188 (206) 431-36710 Permit Inspection Request Line (206) 438-9350 6-e (20 (/S -r— Project; - . Ty - p;btf Inspection: Address: ,-/ �31 .11. r Ti-d Date ca e Special Instructions: Date W t d a-m. p.m. Requestgr I z'V--P' )( 4) Fi%a—' Phone No: I Inspector: j/—� I La,e5-- 1!am — 6 5- 1 E] REINSPEdTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cat[ to schedule reinspection. INSPECTION RECORD /G 0 7G Retain a copy with permit t INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of nspection: Address: Suite #: !� Contact Person: Special Instructions: Phone No.: Approved per applicable codes. F-1 Corrections required prior to approval. I COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ,,�-1 ; 3 1 Date: Hrs.: / d ❑ $100.00 REINSPECTION FEE REQUIRED.�You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. - Billing Address Attn: L Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Z, INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CCU-~1 01 00 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: L- c__-, 4 S I r) Type of Inspection: (f Q.r-- Address: a L ? Contact Person: ., Suite #: �l Special Instructions: Phone No.: Corrections required prior to approval. ❑X Approved per applicable codes. f COMMENTS: /-� [4-- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: / Hrs.: �ni$100.00 REINSPECTION FEE REQUIRED. will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Bming Aaaress Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 0 Oldcastle BuildingEnvelopd 1611 S.E. Commerce Ave - Battle Ground, Washington 98604 oldcastlebe.com - Phone (360) 816-7777 - Fax (360) 816-7775 Bill of Lading # 967174 Order: 914054 PO: LEGO TUKWILA Job: LEGO TUKWILA CustomerNo: 11671 IDue Date: 6/12/15 Ship Date: 6/12/15 Route: 0 Customer: SUPERIOR GLAZING SOLUTIONS LLP 19001 236TH AVE NE WOODINVILLE WA 98077 Ship To: 1611 SE COMMERCE AVE. C/O OBE VANCOUVER BATTLE GROUND WA 98604 Phone: 425 742-5197 Weight: 2,41 Trailer: Stop: 1 Item Qty Description Width Height Shape WeighSq. Weight Shipped p Shipped Qty Prev d Qty 13/0 WILL CALL- LOOSE 1 2 SHWDRS.3 4813/16 137 3/8 47.92 2 112 CLEAR TEMPERED N 313.64 FAB:PE-2L 2 1 SHWDRS.3 12 1/4 137 3/8 13.42 1 112 CLEAR TEMPERED N 87.83 FAB:PE-2L 3 1 SHWDRS.3 LS 11 3/8 137 3/8 11.50 1 112 CLEAR TEMPERED N 75.27 FAB:HD-2 PE-21- 4 1 SHWDRS.3 RS 13 1/4 137 3/8 13.42 1 112 CLEAR TEMPERED N 87.83 FAB:HD-2 PE-21- 5 1 SHWDRS.3 39 137 3/8 38.33 1 112 CLEAR TEMPERED N 250.87 FAB:PE-2L 6 2 SHWDRS.3 34 137 3/8 32.58 2 112 CLEAR TEMPERED N 213.24 FAB:PE-2L RE EIVED JuN 1 s zo15 CIS—Oo PERMIT CENTER PAGE 1OF 0 Oldcastle BuildingEnvelope® 1611 S.E. Commerce Ave - Battle Ground, Washington 98604 oldcastlebe.com - Phone (360) 816-7777 - Fax (360) 816-7775 Bill of Lading # 967174 Order: 914054 PO: LEGO TUKWILA Job: LEGO TUKWILA Customer No: 11671 Due Date: 6/12/15 Ship Date: 6/12/15 Route: 0 Customer: SUPERIOR GLAZING SOLUTIONS LLP 19001 236TH AVE NE WOODINVILLE WA 98077 Ship To: 1611 SE COMMERCE AVE. C/O OBE VANCOUVER BATTLE GROUND WA 98604 Phone: 425 742-5197 Weight: 2 415 1 Trailer: I Stop: 1 Item Qty Description Width Height Shape WeighSq. Weight Shipped p Shipped Qty Prev d Qty B/O 7 1 SHWDRS.3 14 3/4 137 3/8 15.33 1 112 CLEAR TEMPERED N 100.33 FAB:PE-2L 8 1 SHWDRS.3 TRANSOM 71 3/4 22 7/8 12.00 1 112 CLEAR TEMPERED N 78.54 FAB:CN-2 HD-2 PE-2,2 9 2 SHWDRS.3 DOOR 35 3/4 111 1/8 28.00 2 112 CLEAR TEMPERED N 183.26 FAB:CN-1 HD-2 PE-2,2 10 1 SHWDRS.3 SIGN 4813/16 137 3/8 47.92 1 112 CLEAR TEMPERED N 313.64 FAB:HD-5 PE-2,2 TOTAL UNITS: 13 TOTAL SQ FT. 368.92 TOTAL BOXES: TOTAL RACKS: RECEIVED BY: tm DATE: 6/12/15 9:34 UNLOADED BY: DRIVER CUSTOMER BOTH PAGE 2 OF FISHER REVISION NOR-L Submittal # 001 FILE COPY vE E l "'E"li iT 111QUI IED FOR: ..ffMachanical -08ectricai .,UPiumbing , FTGas Piping, C, of i�.�kwiigiar KEVIEWED FOR CODE COMPLIANCE APPROVED MAY 1 3 2015 City of Tukwila BUILDING DIVISION Phone: REVISIONS No changes shall be made to the scope of vmrk v oAwior approval of Job Number; I1537 N(}Tr:-: '"t-'.'!vi$iV tLilil require a r isubmiPpl Job Name: LEGO South Center f !-n l mR» ire•, grinp.drl'fnnA plan roApyt fpps We Are Sending You: ❑ Shop drawings ❑ Specifications ❑ f ❑ Samples ❑ Submittals ❑®PY it Prints M M.— T_1- T,__-___�, Le- a\ f\ f 1 A COPIES DATE NO(s). DES N Alternate Ceiling Framing pdf 05/06/15 Plan re w approval is subject to errors and amissi rov of con ns. 'ze sipt These Are Transmitted Checked Below: ® For approval ❑ Approved as submitted El 3d Field eM and conditions is aC o edged: Resubmit ❑ For your use El Approved as noted ❑ copies f val Submit By: buti ❑ As requested El For pricing ❑ ❑ Returned for corrections ❑ For review and comment ❑ Returnnn��.----co is For coifSf�6L�i Remarks (XY Of u wila -- B I DING DIVISION - Please find an alternative ceiling framing plan from our sub that they would ljka1a4x9ceed with at no extra cost Please respond b s w Rachel By Rachel Gilchrist Fisher Development, Inc. RIGHT Click and choose the Pick From List option and choose from the list of offices. RECEIVED e °C � 6 /a77 R kl�� CITY OF TUKWILA Milangi`"t—tai PERMIT CENTER Revised: W04 t �� i172- r—S 14 *4=0 dope W mo Boyd rlNopo►J W *AP AW6 vu v NM► NM WAWg9W col All Wft PAW - jggp NU M/w 3oo n" Put 4N0Or dW NM =MW* O RjWd ' 4 PW4W WN Nq �4 d P qU MOM IHY ON � O N OMDOP MN O WAOM v a MUMLOW Ne "3o VW o "Moo MiN iwi-NK 1YI N610NIHSdM 30 31V15 3NWHAVH '0 A3808 _1J�31_I TH���d a���1SIS3� p�� d ` � # -,a LETTER OFTRANSMITTAL TO:irSWR Doi ELDl�t�� • DATE: 601 CA"RR 4 � sm,3oo RE: S M uCA%4,, CA. %J to 9 L56o Seel atwmm qzw�Wb ATTENTION: 1kgj,,, tv%L..l`A1r?jbT- We are sending you (Y� Attached ( ) following: NOT kcccrm b ( } Extra Work Authorizations Submittals ( ) Plans/Specifications ( )Other ( } Billing/Schedule of Values ( ) Lien Releas - Original COPIES DESCRIPTION 4e, t EA• ALIVE RKIAW AM CZlUM&- 'FAC-KA&E N"tF AV.R RfiF4t,%95''V1 $'4& APPROVAL drr 1-�W AL-NeeAd. G; .r" epwor 1G cq m%,k sriew-7-v4o "Pswk wauzmeq PSG PA"m CZ S�-tiZ�Cb Q54 -D46%9: AFS AL-50 °a` AM100" Xt4o Qo4 K 7M MpIAMh o15 Wt A 1bN4k&'Vu>VA These are transmitted as checked below: ()Q For Approval ( REMARKS: COPY TO: FILE For Your Use { } Resubmitted ( ) Please Return fjt4P05WD 4Y47VA4 FV2441 TrIA)6 Or SIGNED: ❑ FAX PAGES_ �� �igCt� ti9iBN A O .f - No � Copies A444-07 all' 0 i eeoww L /I "aDVff 0099 VVL SZV I'S`J — 'Z)u2 'SuiegsAs aA9 Nd SS=L0 STOZ-90-AEN 6200 E, Main Ave. &SEA �� �/� ! ne Box 11215 o*'� 1�° �, ' ai j j i ,~' . �''~ �, Spokane, WA 99z 17 Steed Stud Mfg Ed! �''� f f�' 0 9 -' (509) 535-5637 Direct Supplier to the Contractor Fax:{509} 536-7151 Project: Project No: Design: Date: M _...� :. ~ il� r11.7 :1 I rl 1 1 • - I .i �i GYP SYSTEMS INC. 10002 3$fd AYS. W.101 LYNNW00t), WA' 98n36.4710 42i3"- "--MOO FAX 425-744-0661 5 l4 writ -A'AlbNl u5E :1--'�2J Ct1 ��t=t�T�,,T, Sg ia E 9018E -11'AT171' 'AMIAMI NIu Itrtu LAND TACOMA YAKIMA , 1 s09% PO: 22ppgg,,023A001 Pb:420.+1OD.TG++ tn+: ulc:.G�n.rmu IM: Wn:1.a"A/bu 1'11: ?S3274A93a Ph 9U0.A52.6//» We 11b1 i1C 200.920A017 Fx: 42G.400.7000 rx:01A.A'7.4.bbAA f--N l.UZiG04 F., 200274JIMA ry. $(NlAM, 41110 I x: TIOARP TRWNTlrl: s jm l•U0:/11�E MEDFORO I111tANtYi MPROLAA Ph: 002A20.0404 FIV 000.042.141t Nb•00:f,a+1.e(1:19 foe ON.YU600f1 Piw 041.yyT�3.8040 v1,; 4W1s.411,JWAI 1%:40AS0,70 Frt 503.020.0414 FK 000.042.0700 Fx: 000.100AtvI ex y11.xSYr44 Fa. 041.7T0.0448 F1e 400,2401WO Ir. 400;N✓.M of 4� L /Z 'aDV6 0099 b6L 9ZV T'S'D - -orzz 'sivagsAs dAg WcT 99=LO STOZ-90-AEI ,F— - 4o.f-f-s 6200 E. Main Ave, POBox 11215 .5"FE17 > Spokane, WA99211 CO.* (509)535-5637 Steel Stud Mfg L Direct Supplier to the Contractor Fax: (509) 536-7151 No: GYP SYSTEMS INC. JqdW33rdAVER W;101 UNNWOODt WA M3&01.0 Q&744-6600 FAX 425-744-Ml. .0i A LAI] 916' ON XII i M- bcm0wmFmommoomm REVOW AS 8Wft tN094mfWA"�mwmmUIw ---- i*okuftly for =dimwIb$iI6 dhgl dramgio and grA ,_a=gjdwhMhm Ift0ty unOLds shWthwk _,7/� - BY It Ste g.t,..r7- AMU, spoN4le SgArTLS &CRAME KAYWA.IW Mr. 006 3N.VAT F111: 11r1IT1,091 t. OiOA07T70011 Ph: 503. 700 P P�M P74.W.13 m—".452 GiV809480 Pt:,":�� 71.11 J:X: VIV373 4017 1 4Y5,4tM. PA5 FW:.M6.f*4.3NA F. SUMER F'Z.'2111 VII,"Mill r. WOA521737170 FL 00:780:9430 Iftmew TRI-WJES SALEM ruc;r3W mholl (Nil) MIGSUULA Page; of e �. 070 ~4 1 -h! 503.371.11039 frc G41.301.8m FIC 311 773�3343 =292000 1914W. �LVW 11W IW 1! V. W13.9ft 1.09 r I 1IM14 2. Z .1 "71 Fx G41.$40.2744 F� C.4 77� 0444 1 —1001.246.0480 F.A754511 n: /P "HE)VCT ongg VV/. 47b 1,S,g — 'OUT 'SIU02sAs dAq we qq:fn qTn7-qn-A-eiq 1W 5t4s�l5tudMfg. Co. Channel Prooe.rties w�w��wwwwiwiwi�,wi �• ��•��ii i i i u•w nuunn ni U - Channel Section Properties Non, Ban MeW 1 Daslan l n$" Thlo4pas Thwkewr Ana JIM 1tx W ay hm 2 4)sx Nb M n e M hd 075U50.64 "536 0.288 0.002 0. 19 39.0 150UW64 0.009 0.0586 0.120 0.099 0,64a 0.002 0.144 D.tt39 0,052 10213 MOU5D-54 0.0535 40040 0.167 0.079 0.710 0.002 01138 0.070 0.070 166.7 250U" QANA 0,05W 0.186 01140 0.807 0.0m 0.128 DA40 220.E U r: t*/ MOW Cf%/1l�llr�a/� rtrNtw�lt y" N� l ipt Q�l t'T l l�1 �I t�0110EP1 AS NOW ffma xnoN•c�+���wa tt�lwr -pfitsb wNrwedtw ow" earllor w" VA daldop aoaoept 0* X and dne not rnUw the fdvft r - uwlira rosponsli ft for cd,t Mu= To dwp 40 3%4'I 1 !fz" d Aft and epsd k*M, M d Wft Valid 2s on 00* 0rer tt,le dM *Wft U - Channel Allowable Ceiling Spans L1240 Thlok• IP+t sow 3600 BoomCumm eve0ng On) o.o. 00n41 so" (in) e e Clanno OpeWna fin) e•a Chennal SWbg (in) ae. M2L 39 41 so .L2. 24 Singla 0" 31-V 3'-1" 2.10" 7.8' 3 4' 7-11 2' -4" 2'•r 2'.3' 2N• t'-11" $ 7- 1'-1 " 1 079Ue0 64 Mu19 4'49• 4',r 3'-86 3'-" T4 7 V-r 31•4• Ill" 2'.10" 3'3" r-W 21.1" 2-1" 3'-1 _Zr 7.2" 1-1f " 1501)60 61 S. RAW 4-,r4'-t" 3'-10' 41.10" W-P v-t0' T.r T-C 3'-9 W-3" 2'-111. 7.e1 3'.7" Y-r 7.0• zr b• r-- e45" TAW 5-r Q=t' 6'-6" 9-7- 6.1• V.W 11-V . s-D'. 4S' T40' a'-r 410 4'-11 sir 3'r" 5'-9" 5'-1, *-r 41-V 41-0" 0'-1• 4'•r 4'-0' 3'-9" 3W 6'-11' T-6• 3•-2' 7.11• 3'A- 3'1 0' 7-10" 200U50 540"fiq M b r4r (r r 6'-r T.S. 9'4• 61-' IF41• @ - 5'-0- c4r S-3• 4'4" 4•4 9'-10" W-0" 4W 4.0• 31-r ZOO Single V0 8.3• 4'-10• 4--e 0.3. $'.9" W-r W-V a'•11" W4r 4'-1" 8'-r 3'•a 3' 1 9'-11" 9'-5" 3',2" 2-11" 54 8.1V 4'•t1' W-7" r-0' 6'.2' 51 r 61-2" 4'-1i" b'-6" 4%V C-4 4ti1' 9-2* 4'-7" 4 2" 3'-1(' U - Channel Allowable Ceiling Spans L/360 714eN. _. . • • ... • 4 _. '• a ga1.:. ••,. .. , ..:.: ' ..., saeden nags SPAN clwuMt $P1 WtW (in) fm Gunnar Spacing on) o,a ch""I $*INN (in) e e Channel ep■e61g (In) o c. ntffad so a 40, 72 24 24 36 4t• 07Ft1Rn r,4 W4 3'-4" 2'.1t• 2'-8" 2-8" 7-A• 2'-tr T- III •4" 2•.2' •0" 2'.3" z•P - MtM 4'.2• 31.9• 314" 3'-1• 7-111 IV S-r 2'-1" 2' A•� 2'•10• 7.6" 741" 7.1• 2'66' 74" r-1' 1'--11• -OW66 4A , ` V-V 4'-!0" 4'-4" 4'-1" 3'.1a 4-J0• 4'•2' 31-10" 3'-r 31-4• V-9- s'-r 2.17 24r T r x r 7,9• 7-r - r-e 0'49' 5-10' 6'-V 4-1' o,-r w.r s-1" 4W 4-5" 4'-ii' R-T 3'-10• 8' 4-g' 4'•1' 9'-7" 8' 3" " J,, -9" S-1" 4'•7' r-7 4'4r 5'•1' 4'.r 4W. W-9" 3W 341" a-T 3'-2. 7.11• T-W 3'.4' 3'4r 2'-10" wra r r rAr a•-r sw S'.1' 614" &-11" •Ir -0" 41.81 5'.3" 4;r W-2• 3'-W " 4'-4' 4'•7 3'-9" Si"Ble r'o" Wr 4-101 44r 4141 E'-3" 4'r W-W 31,11, 31-W -1" 3'-r -4" 3'.1• 3-11" 3W 31-r 7.11, MOW 64 ,11^ s-r 7•a• 8-r 6'r 9-r 4'41' a'-5' 4'-(r 4.0 4.1" P B,2" 4'•r 42' 3'-1b Allowable calling spans based on eifective properties. Multiple span Indicates two or more equal spans with channel o"nuous over center support, Hearing length Q 0.761- Table values based on the compression flange laterally unsupported. L /V '=d 0099 VVL SZV I"S'D - -0u2 'sure-4sAs t3%E) Wd 9S:LO STOZ-SO-AEPQ Channel. Properties (Hat) Furring (F) th�'anh*p"1-'Settion"'Pr.operties Section Mir. BAY* Metal rhimw" Am VA IFW 0371,125-1 0 0 0.0188 0.070 0.008 2.6.4 CVF125-27 OAM 0.0283 0.104 0.013 44.8 08717125-30 0.02g8 0.0312 0.118 0, OU 50.3 087FJ26-23 OW§ 0.0348 0.12T 0.015 55A 067F125-43 0.0428 2* 0.183 0.010 70A 1 GOP125 18 0.0179 0. as 0293 0,029 55.4 IOOFI 26-27 0.0260 0.0283 0.140 0.045 BSA I 5OF125-30 0.0298 0.0312 0.154 0.050 104.9 16ON2W3 0.0329 OAW 0.170 01055 115.13 7SOF125,43 0.0420 0.0461 02M 0.070 147.6 I Minimum bare metal thickness is 95% of design thickness. 2 Moment of inertia given is for deflection calculations, 3 Effective properties are given as the minimum value for either pooltive or negative bending, 4 Effective properties based on ry ft 33 kist. 13 CWMG FOR NM CWWj 13 MWAIS FOR DE111111111111ill ME" VM FWAM AS SHWA )(NOMW=111111111111113 WM AM MWW Tlft OM *Wft ho bm WWnd for Owd cmbmnr,os WMd1*nMqrr1jlO* X_ RW does not M1111we ft it MU - VWder d MSPMdDi* fOr C1111111onrtarice w1h des1W dmw,.'V NW VwftzWm, d of Wft hm WiOft OW fhb shop drawN. -A BY Do. 2 1/4 h y I k MIN. (Hat) Furring (F) Channel Allowable Ceiling Spans L1240 W "Ell � "971, '��A' M �" V... r•'R%111 Py cocoon Roans .- OM Jvlat Speding *.c_ - (kel) jolA Gowling (kj) o-v, Qn1 12 .24 12 Is 1 61 L '12 24 Single IT4, W4r 4'-1* 4.6" itl33 V-51 6.10, 1. V-7- U-11 44" 41-M 3W X-icr single &.11' �5-w Fe Fr 27 33telex t-4- �4P 5-1 W F4 S_Jr. 3W aftlaw V_r T_r 4'.I0' 41.10* 4W 9871"125 30 53 MUKIP16 - 7'-7' V,ti' ty-W 0.4r F-W T-ill, 5.t. W-3* TW 33 33 33 MLOA V-10. I- V-W 4' 43 33 641" T-F O'e" - O'.r T4" Fir 7 -7' e 61-3 4.0- T-11 : 18 Multiple. .041"- 7_1r' Sinilb nil. T-2' V41' e-110" 1 27 33 Multiple, 11%2' 1 W-ft' •r4r 6'41 6W 6W • IrV 5417 ISOF126 .30 L 33 MA& 97t V-r OJ single 6W_ 71-W 8.5" rr &-a" 33 33 MUKip IV-61 WW 9`41 a, -IT r r4* 51-11- zd F-7- 43 1 t4-r 610 Allowable coiling spans based on effective properties. Multiple span Indicates two or more equal spans with channel continuous over center support. 46 Beating length m 0,75". L /S -myci 0099 VVL SZV I'S'D - 'DUI 'SU1949AS CIAD Pqd LS:LO SlOZ'90-AL-W L¢fll�tettt I lralues are jor singk spans 2. Forfully braced celNngs, use mid -span values I End bearing length is 1 inch minimum 4. 30E42D Galvanlltng to be G40 Minimum for 10 P$F or less 4139MD 6-60 Minimum for Greater than 10 pSF Lateral toads S. 33EQD to be 6-0 Galvantted Minimum with 0.0235' Design Thickness Example of Ceiling Mld-Span Bracing P01 BEs�t 001�r � `� "Ci�ONF�i1�16 fal f>�I O���II FEASIM AS SQL This shop dtw" No 111M WON for conbrrnt= w• rwP *0w a* ttb d0K sot Rk" t* f>rAWW-VWMd taspae Ulti for c ft.rw wilt d P sum rwm snro drawinti and spwftaft rs, d d wlft (1 priority uver rids shM dmwft rASTM sraa.e hhothn G.S.I. � RAT QMwMVW GYP SYSTEMS IAS* 19M 33rd AVE. W. 401 LYNNWOOD, WA 08036 4" 74 ,r>C► FAX 425-744 I-EC70 SW www.$CAFCO.com 8-< 0 2011 SCAMOarporatfan LaV00011 and supersedes all previous lrlfarmadan. • L /9 '=d 0099 VVL 9ZV I'S'J — -Oui 'sU1a-4SAS ddE) ➢rid LS:L0 Pi. 1 ot-I Jt SFS I' {I1r.W t irW t+0 tMiRM' STOZ'90'�� r7 Supreme Drywall Stud Section Properties 16293.30EQD 0.0235 0,117 0.40 0.055. 0.068 0.684 0.035 0.543 0,052 0,048 136 621 0.022 0.027 0.776 .1.359 1.616 0.292 25pfiF5.30EQ0 0.0235 0,138 0.47 0,145 0,116 1.025 0,041 0.542 0,236 0.090 255 505 0.02S 0.060 0.716 -1.212 1.677 0.A78 A505FS-30E0.D 0.0235 0.161 0.55 0.313 0.279 1.392 0.046 0.53i 0.304 0,112 319 $51 0,030 0,119 0.659 -1:D83 1,842 OASS 3625FS-30E00 0.0235 0.164 0.56 0.339 0.287 IA97 0,046 0,529 0.331 0,13.6 331 330 0.010 0.128 0,652 -1.069 1.867 0.672 4OWS-30EQD 0,0235 0.173 0.59 0.427 0.213 L569 0.047 0,524 OA17 M129 N7 305 0.032 OAS9 0,634 -1029 1949 0.721 6003F5.30EQD• • 0.0235 1 0,220 1 0,75 1.112 10,171 2.247 1 0.0$3 OA92 10.976 1 0,219 622 1 200 :1 0.041 I 0.388 10.553 1-0.9641 2.4S7 0-076 1, Gross Properdes based on full-unreduced cross section of the Studs, away from punChouts 2. For def iecd6n ealcufations, use effalve moment of Inertia - � � � 3.. Web -height to thickness mdo exreeds 200, web Afters ers required at all support points a � M 4. 33EQ0 to be G-60 G41vanized Minimum with 0.020V Design thickness - d`MOxaleMkioer�..6.e ......�, Supreme Drywall Track Section Properties Mgq �11( ii41 ';.i7 "� ;� x. N�ilf r :w •. ,A;. •J"•"Y.:. � tY.r A' �Ml r'•y;�°' V� 0.060 162SFT125-30EQ0 0.097 0.33 0.052 0.734 0.016 0.410 0.018 0.009 0.502 o.87a 1.213 0.491 1625Ffi5030EQD 0.109 017 0.061 0.070 0 749 0.027 0.496 00, x _ 0.623 162%7200-30EQD 0,132 0.45 0.079 0.090 0,771 0.058 1 0.661 0.024 0.032 ;>37 0,295 250SF7125=30EQD 0.118 0.40 0.130 0.099 1.052 0.019 0.399 0:022 OA23 OASS -0.765 1.361 0,684 25WFTISD-SMQD 0,129 0." 0.150 OA14 1A77 0.031 0.487 0.024 0,037 0.576 -0.979 1:535 0.593 250SFr20D 30EQD 0,153 0.52 0.190 0,144 L115 0,067 0.660 0.028 0.080 0.916 -L424 1326 0.453 2505FT250.30EQ0 0.176 0.60 01230 0,175 L142 01321 0.829 0.033 0.148 1.059 -L885 1 2.365 0.359 350SPT123.30EQD 0,141 0,48 0.215 0.151 1,396 0.021 0.381 0.026 0,048 OA17 4673 L595 0.922 350SFTlSO.30EQD o.153 0.52 0,313 0,172 L431 0,034 O.A71 0.028 0,078 0$30 -0.871 1.740 0.749 SSOSFT200-30EQD 0.176 0.60 0,389 0.215 1A86 0.074 0.649 0.033 0,170 0-763 -1.291 2.072 0.612 3SOSFT250.30EOA 0.200 0.68 OA66 0,257 1,527 0,135 0.923 0,037 1 0.311 1,002 -L731 2.450 1 0501 362SM25-30EQ0 0.144 0.49 0.297 0.158 1.437 0,021 0.379 0,021 0A52 0.412 -0.663 1.628 A.834 362$FT150.30EQ0 0,156 0.53 0,338 0.180 1,474 0.034 0.469 0.029 0.085 0,525 -0.859 1.7699 0.764 1 3625FT200.30EQD 0.179 0.61 O.A20 0,224 1,531 0,075 0.647 0.003 0,184 0.758 -1.276 2.095 0,629 3625Fr250.30EQD =3 0.69 OS02 0,267 1.573 0.137 0,922 0.031 0.336 0-495 4.713 2.467 0.518 400SFT125.SOEQP 0.153 1 0.52 0.373 0.181 1.562 0.021 0.373 0-028 0.065 0.399 -0.635 L727 0.865 40%FT15O-30EQA OASS 0,56 0,422 0.205 1,602 DA35 0,462 0.030 0,106 0.510 -0.826 L861 0.903 4005FT200.30EQ0 0,188 0.64 0,521 0.252 1,665 0.077 0.641 0.035 0.229 0,740 -1.234 2.169 0.676 400SFr25D-30EQD 0.212 1 0.72 0,620 0.300 1.712 0.141 0.817 0.039 0.419 0.976 -LW 2.523 0,565 GWSFT125.30EQD M200 0.68 0,970 0.817 2.204 M023 0341 0.037 0.163 0,340 -0,520 2.290 0.948 600SFT150-wQd 0.212 0,72 ivoO 0.352 2.259 0.039 0,428 0.039 0.267 OA42 -0.688 2A00 0.918 600SFT200-3GEMD 0.235 0.80 1.299 0.424 2.351 0.086 0.606 0.043 0.578 0,659 -1.053 2.646 0.842 600SFT250-30EQ0 0.259 0.88 1.519 4 S.. ;t42j0j 0.159 0.795 0.048 L052 0.883 1 -1-446 2,929 1 0.756 section plgperties shown orl f ectlan 81. IMEW to be 6-60 Gohohizcd Minim EViPK1TF1 G.S.I. GYP SYSTEMS iN�. N1D 19M 33rd AVE. W. t0'1 . inb sttb0 tliw�p rue Iw�wrNrrad tar p WA 98036-00 a ca+lottttrtarrMtiilj catceoCotdl�: LYNNWO end tlaN riot nlwa 1A� abtl�loc ,wtaa of retvh►.rucei%r:nte.:�. 425 74Q-66( F A-744-0561 Irm-Aw-_ ,over,t!* strap tltiwbp:: . _ - r sew TX LjPirt,, o f 'r OeR •GfZA V s j$ r'eM www.5WC0.•C0m fibewsru A2L Effective 0110112011 and supersedes all previous infoawtion. ® 2011 SCAFCO Corpomtlon 5 f)f199 T7h1 g7.tr T'S'f) - 'OUT lswwaSA9 t3KE] Wr7 Rc:i I CTr17-Cn'2AEW PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0049 DATE: 05/11/15 PROJECT NAME: LEGO SITE ADDRESS: 837 SOUTHCENTER MALL Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: W)V Building Division Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Fi a Prevention 0 Structural ❑ Planning Division ❑ Permit Coordinator it DATE: 05/12/15 Structural Review Required ❑ DATE: DUE DATE: 06/09/15 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT C00 0 COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0049 DATE: 02/26/15 PROJECT NAME: LEGO SITE ADDRESS: 837 SOUTHCENTER MALL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # DEPARTMENTS: Binding Division Public Works PRELIMINARY REVIEW: Not Applicable ❑ (no approvallreview required) REVIEWER'S INITIALS: Revision # after Permit Issued I l 1 �Mb �- I,-K Fire Prevention 9 Structural ❑ &FL, lq&�, S^1,4S,� Planning Division a Permit Coordinator N DATE: 03/03/15 Structural Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/31/15 Approved ❑ Approved with Conditions 81 Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PROJECT NAME: SITE ADDRESS: 6 PERMIT NO: bis — ©Q ) 9 ORIGINAL ISSUE DATE: 3 -.(o— REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIAL Summary of Revision: �� �,,� Ate. Received hv- ?"FAiP Y .0 , ). o n ,—, 1 REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.Tukwi]aWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /� Plan Check/Permit Number: f 5 a V ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued A I.T. ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: L Feo o Project Address: 937 Contact Person: %R S/ M Uit1_D b'7tJ Phone Number: ) 5..f ' G 70 - o) SJB' Summary of Re7iW;riR E C W #Aze, ik -S,44 6-C to l 0 0 0- G,W-7t I �A/ !o fA0 AP! 7' - B/}2 G x tiD S-J/j--.*o SCE �''.lgf--� �, � OG e"�c1.s�7NL ,o,[,�i�.(/GS'• PERMIT CENTEP )T Sheet Number(s): e a ' oC "Cloud" or highlight all areas of revision including date of revisio ) Received at the City of Tukwila Permit Center by: _,D Entered in TRAKiT on FISHER DEVELOPMENT INC Page 1 of 2 Home I.rucio en Ispan"ol Contact Safety Washington State Department of Labor & Industries FISHER DEVELOPMENT INC Owner or tradesperson FISHER, ROBERT S Principals FISHER, ROBERT S FISHER, JAMES R FISHER, ANN C MORESCO,ROBERT ALFARO, DENNIS (End:01/01/1980) Doing business as FISHER DEVELOPMENT INC Search L&I A-Z Index Help 41y Secure I &I Claims & Insurance Workplace Rights Trades & Licensing 201 SPEAR STREET SUITE 220 SAN FRANCISCO, CA94105 415-228-3047 WA UBI No. Business type 600 170 375 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. FISHEDI141 PT Effective — expiration 10/30/1986— 03/05/2016 Bond ....._.......... INTERNAT'L FIDELITY INS CO $12,000.00 Bond account no. 0442275 Received by L&I Effective date 04/17/2008 05/21/2008 Expiration date Until Canceled Insurance .......................... Hartford Fire Ins Co $1,000,000.00 Policy no. 57UENQT7115 Received by L&I Effective date 12/08/2014 12/01/2013 Expiration date 12101/2015 Insurance history Savings N ................ o savings accounts during the previous 6 year period. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=600170375&LIC=FISHEDI141 PT&SAW= 3/26/2015 '— �r=r_ 1 I4UI"I0=K UrILINW Mr -IL P1 I ULL7. r171 . i I IVI\-/ 1-LI\I VI\ 1 LAV CENTER GTR. PLASTIC LAMINATE PLAM. VI VI\ VVI"11 LL I IL IiVI\I\, WIC I IY\V I VI\ 1✓ I V VL I!"�I1i r� VLI\ 111 mwr" l L VI COMPLETION FROM THE LANDLORD AND A GERTIFIGATE OF OCCUPANCY AND ALL Gross Floor Area 1,&23 sf 1275 / 30 43 GENTERLINE GL PLATE PL. NEGE55ARY APPROVALS FROM LOCAL BUILDING DEPARTMENTS OR OTHER AUTHORITIES Floor Allowance Area Sales - 305f \� �I Y 5� 0IVS 768 / 300 3 ELEVATION NUMBER CENTER OF G.O. PLYWOOD PLYWD. HAVING JUR15DIGTION OVER THE PROJECT. BOTH CERTIFICATES SHALL BE SUBMITTED TO Stock - 3005f NO. DATE DESCRIPTION CASEWORK ELEVATIONS CHANNEL CH. PREFABRICATED PREFAB. LANDLORD AND OWNER. •— SHEET NUMBER COLUMN COL. PROJEGT/PROJEGTION PROD. __ __..._ _._. Total Occ ant Load 46 GONIROL/GON5TRUGTION JOINT G.J. POINT r I . I H= c7 N=Kf'1L UUIN n<^U I UK HIVE HLL =Ut7UUN 1-"U I UKn �ttHLL UUN I PAIN H =/Nr1KIV I CC 1.5.15 PRELIMINARY DESIGN SUBMISSION CONTINUOUS CONT. THAT THE WORK PERFORMED SHALL BE FREE OF ANY AND ALL DEFECTS IN WORKMANSHIP CEILING TYPE (LETTER) CONTRACTOR GONTR. QUANTITY QTY. AND MATERIALS FOR A PERIOD OF TIME GU5TOMARY IN THE TRADE, BUT IN NO CASE LE55 123.15 QUALITY CONTROL REVIEW GEILING DESIGNATION GORRIDOR GORR. THAN (1) YEAR AFTER PROJECT COMPLETION. DEFEGTIVE MATERIAL OR WORKMANSHIP RADIUS RADIUS WITHIN GUARANTEES TO BE WRITTEN TO THE BENEFIT OF THE LANDLORD AND OWNER 50 5 ACCESSIBLE BUILDING X Designated 22.15 TENANT COORDINATOR SUBMISSION GEILING HEIGHT (NUMBER) DEGREE DEG. REINFORGED/REINFORGING REINF. THAT THEY CAN BE OtREGTED BY EITHER. Non -designated 225.15 I55UE FOR PERMIT DEMOLITION DEMO. REQUIRED REQ'D DEPARTMENT DEPT. REVI510N/REVI5EO REV. 3. A5-BUILTREGORD5 NAME DETAIL OET. RISER -R ROOM NUMBER NUMBER DIAMETER DIA. ROOM RM. THE GENERAL CONTRACTOR SHALL PROVIDE AN ACCURATE -RECORD OF 'AS-B6. MINIMUM PLUMBING FIXTURE COUNT REVIEWED �O DIMENSION DIM. CONDITIONS TO RECORD ANY VARIATIONS FROM WORKING, ENGINEERING, OF SHOP MERCANTILE-M # Re ulred # Provided DISTANCE DIST. SANITARY NAPKIN DISPENSER 5.N.D. DRAWINGS AND TO INDICATE THE ACTUAL 'GON5TRUGTEOGODIT ' NION5 WITH PARTICULAR DOOR DR. SANITARY NAPKINREGEPTAGLE 5.N.R. REFERENCE TO WORK WHICH WILL BE 5U55EQUENTLY CONGEALED. UPON COMPLETION OF THE Water Closets I 1 ,()DE COMPLIANCE DOOR NUMBER NUMBER/TYPE DOUBLE DBL. `•. SCHEDULE 5GHED. WORK, THE GENERAL CONTRACTOR SHALL LEAVE (1) SET OF DRAWINGS ON 517E IN A PVG Lavatories I 1 APPROVED DOWN ON. 5EGTION SECT. TUBE AND DELIVER TO THE OWNER AND THE LANDLORD (5) HARD COPIES AND (1) DIGITAL Showers - - WINSHEET SHT. G DWG. Drinking Fountains - 1 6 DRA COPY IN POF FORMAT OF MARKED -UP DRAWINGS REFLEGTINe 5UGH VARIATIONS. THESE 5ervice 51nk5 1 MAR SIMILAR SIM. DRAP0675 ARE IN ADDITION TO ANY 'A5-BUILT' OR 4REGORD' DRAWING5 THAT MAY BE DEMOLITION TAG EACH EA. 50AP DISPENSER 5.0. -REQUIRED OF GONTRAGTOR5 UNDER VARIOUS TRADE SECTIONS. NUMBER ELEGTRIG/ELEGTRIGAL ELEG. SOUND TRAN5M15510N GLA55 5.T.G. Cj of Tukwi a ELEVATION EL. SPECIFICATIONS SPEC. 4. FINAL GLEANING EMERGENGY EMG. SQUARE 50. -i. FIRE PROTECTION X Sprinklered VILDING DIVI tQN WALL TYPES EQUAL EQ. 5QUARE FEET/FOOT 5.F. THE GOMPLETE PROJECT SHALL BE PROFE55IONALLY GLEANED PRIOR TO ACCEPTANCE Non-sprinklered NUMBER EQUIPMENT EQUIP. 5TAINLE55 STEEL ST. 5TL. DATE. THE GLEANING SHALL BE COMPLETED BY AN INDEPENDENT 5UBGON7RAGTOR EXISTING EXIST. '• STANDARD STD. 5PEGIALIZING IN 5UGH WORK. THE GLEANING SHALL GOMPLY WITH MANUFACTURER'S EXISTING FIRE EXTINGUISHER EXFE STEEL 5TL. REQUtREMENT5 FOR ALL MATERIALS USED. FINAL GLEANING BY THE SUPERINTENDENT OR REVISION NUMBER NUMBER EXISTING 70-REMAIN ETR. STORAGE STOR. OTHER TRADES 15 NOT ACCEPTABLE. FINAL GLEANING SHALL INCLUDE ALL AREAS 8. APPLICABLE CODES 5TRUGTURAL 5TRUGT. INGLUDING PUNCH L15T WORK. Dated. N SUSPEN51 N SUSP FEE 1 /FOOT FINI5H/FINI5HED FT. FIN. SU , 5PE D/ O j SURFACE SURF. THE GENERAL CONTRACTOR SHALL PROVIDE A TRASH CONTAINER FOR USE BY ALL TRADES City Bullding Code DATUM /ELEVATION /LEVEL LINE — — FIRE EXTINGUISHER FE. SYSTEM 5Y5. FOR REMOVAL OF CONSTRUCTION DEBRIS FROM CONSTRUCTION START UNTIL FIVE DAYS FtRERETARDANT F R. AFTER THE STORE 15 OPEN. LOCATION OF CONSTRUCTION TRASH CONTAINERS MUST BE State Fire Code FIXTURE FIXT. I TAGKBOARD T.BD. COORDINATED WITH THE LANDLORD. EXISTING GON5TRUGTION TO REMAIN FLOOR FL. TELEPHONE TEL. FLOOR DRAIN FP. TEMPERATURE/TEMPORARY TEMP. THE GENERAL CONTRACTOR SHALL BE SOLELY-REFOR ALL TRASH REMOVAL Plumbing Code FLOOR FIN15H FF THRESHOLD THLO. FROM THE PREM15E5 AT THE END OF EACH WORKING DAY. NEW STUD CONSTRUCTION FURNI5H/FURNI5HED FURN. THICK THK. Mechanical Code TOILET TLT EXEGUTE FINAL GLEANING PRIOR TO FINAL PROJECT ASSESSMENT. GAUGE GA. TOP OF T.O. GALVANIZED GALV. `•. TYPICAL TYR GLEAN EQUIPMENT AND FIXTURES TO A SANITARY CONDITION WITH GLEANING MATERIALS Electrical Gode SOFFITS /OVERHANG ABOVE — — — — — — GYPSUM BOARDGYP. BD. APPROPRIATE TO THE SURFACE AND MATERIAL BEING GLEANED. j UNIT HEATER U.H. ADA HANDICAPPED H.G. UNIT VENTILATOR U.V. REPLACE FILTERS OF OPERATING EQUIPMENT. 2012 IBG with ammendments 2012 IFG with ammendments 2012 WSPG 2012 IMG with ammendments 200& SEATTLE ELECTRICAL CODE AN51 111.1 2005 I I HEIGHT HOT. I UNLE55 NOTED OTHERWI5E U.N.O. 1171QLE COPS' HOLLOW METAL HM. 5. PROJECT GL05E-OUT 5UBMITTAL5 ILAN ACCESS. CLEAR FLOOR SPACE I I HORIZONTAL HORIZ. VERIFY IN FIELD V.I.F. on I 30"x48" CLEAR FLOOR SPACE I VERTICAL VAT. THE GENERAL CONTRACTOR SHALL DELIVER TO THE OWNER, BEFORE FINAL PAYMENT 15 , INGH/INGHE5 IN. OR " VINYL GOMP051TE TILE V.G.T. MADE TO G)=NERAL CONTRACTOR, A WITTEN WARRANTY FROM THE 6ENERAL CONTRACTOR, � L — — J INCLUDE/INCLUDING INGL. IN THE FORM PROVIDED BY OR ACCEPTABLE TO THE OWNER THAT ALL LABOR AND Plan review approval Is subject to errors and omissions. SEl' esTl: PERMIT INFORMATION INFO. WATER CLOSET W.G. MATERIALS FURNISHED AND WORK PERFORMED BY THE GENERAL GONTRAGTOR ARE IN Approval of construction documents does not authorize REQUIRED SCR' 1 i IN51DE DIAMETER I.D. I WEIGHT NT• AGGORDANGE WITH THE REQUtREMENT5 OF THE PLANS AND SPECIFICATIONS. FURTHER, AGGE551BLE ELEMENT INSULATION INSUL. WITH W/ SHOULD ANY DEFECT DEVELOP DURING WARRANTY PERIOD, AS HEREINAFTER DEFINED, DUE the violation of any adopted code or ordinance. Receipt Mechanical INTERIOR TNT. WOOD WD. TO IMPROPER MATERIALS WORKMANSHIP OR ARRANGEMENTS THE SAME SHALL UPONElectrical of app►ovod Hold Copy and condition is ack wle d: WRITTEN NOTICE, BE MADE GOOD BY THE GENERAL CONTRACTOR WITHOUT EXPENSE TO THEDf ° JOINT JT. OWNER AND THAT ANY OTHER WORK AFFECTED IN GORREGTINe SUGH DEFECTS SHALL ALSO �y. l� Gas Piping ° BE MADE GOOD. NORDSTROM maCyls ° KIGKPLATE KIP. D ,e: 3 /S THE WARRANTY PERIOD SHALL BE FOR (I) YEAR FROM DATE OF STORE OPENING OR DATE City Of Tukwila o a o 0 0 1 0 LAVATORY LAV. OF FINAL ACCEPTANCE BY THE TENANT WHIGHEVER 15 LATER UNLESS A DIFFERENT PERIOD Sul MNG DIVISION � �� LIGHTING LTG. OF TIME 15 EXPRE55LY STATED UNDER ANY TRADE SECTION OF THE SPECIFICATIONS. City of Tul�wila o 13UILDINO DIVISION THE GENERAL CONTRACTOR'S WARRANTY SHALL COVER ALL WORK UNDER CONTRACT, WHETHER OR NOT ANY PORTION OF TRADE HAS BE SUBLET. IN THE EVENT ANY PORTION OF THE WORK 15 PERFORMED BY CONTRAGTOR NOT UNDER THE GONTRAGT, THE GENERAL GONIRAGTOR SHALL OBTAIN FROM SUCH CONTRACTORS THEIR WRITTEN WARRANTY, IN THE 0 FORM PROVIDED BY OR AGGEPTABLE TO THE OWNER, GOVERING THEIR-RESPEGTIVE REVISIONS PORTIONS OF THE WORK FOR THE PERIODS SPECIFIED, AND THE GENERAL CONTRACTOR SHALL THEN DELIVER THESE TO THE OWNER TOGETHER WITH THE GENERAL GONTRACTOR'S No changes shall be made to the scope WARRANTY. THE GENERAL CONTRACTOR'S AND 5UB00N1RAGTOR'S WARRANTIES SHALL BE Of vmrl< evithout prior approval of _ ENFORCEABLE DIRECTLY BY THE OWNER. Tukwila Building Division. 2: R13visions will require a new plan submittal and may include additional plan revir--m fees. CS I OE5GRI PTI ON DIVISION GO PITIO 5 OF THE CONTRACT o SENERAL 00NDITI0145 PERMITS FEES AND NOTIGE5 FILE PERMIT APPLICATION ------- ------------------ ---- PICK UP PERMIT AND PAY FEES 5EGURITY DEP051T SEN ERAL REQUIREMENTS BARRICADE BARRICADE C3RAPHIG5 PAINTING BARRICADE -2 SITEWORK DEMOLITION 3 CONCRETE__ ------- ------- -------------------------------------------- GONORETE PATGHIN6 (FLOOR GORING 4-RENGHIN(9) 6 WOOD ANP PLASTICS CARPENTRY _ BLOCKING GU5TOM CA5EHORK: - GOUNTERTOP5 ------------------------ --------------------------- _.-.-....-------------- -------------------------------------------------------- ---------------- -------------------------------------- - 5ALE5 AREA WALL 5TANDARDS -- - --------------- --------------------------------......- - 5ALE5 AREA WALL FIXTURE5 - DIGITAL -OUT -OF -BOX - NON 5ALE5 AREA MELAMINE SHELVING ---------------------------------------------------------------------------------------------------------------------------- GA5HWRAP 5TATION5: - GA5EHORK - 015TRIBUTION CONDUIT FOR P05, TELEPHONE, ELEGI`RIGAL - GA5EWORK INTEGRAL GONDUIT5 AND BOXE5 - GA5EHORK INTEGRAL WIRING AND ELECT. DEVIGE5 - ELEGTRIGAL WIRING 8 DEVIGE5 PANELBOARD TO GA5HWRAP - TELEPHONE 4 P05. HfRIN6 TELEPHNE 4 P05 . DEVIGE5 - DOORBELL BUTTON WIRING AND DEVIGE5 5TANDIN6 AND -RUNNING TRIM: - 5ALE5 AREA 5A5E -BAGKER5 "I THERMAL ANP MOISTURE PROTECTION FIRE5TOPPIN6 .JOINT SEALERS a POOR ANP WINDOWS METAL OOOR5 AND FRAMES ALUMINUM ENTRANGE5 AND 5TOREFRONT5: - FRAMING, PANEL5 4 TRIM - ------------- - - 5TAINLE55 STEEL HRAP FRAMELE55 6LA55 ENTRY DOOR5 DOOR HARDWARE -------------- ------------------------------ _..---- 6_LAZIN6: - 5TOREFRONT5 - OEGAL5 44 FINISHES GYP5UM BOARD 5Y5TEM5: - BOARD, FRAMING rt BLOGKING - INTEGRAL HALL 5TANDARD5 - 5ALE5 AREA PERIMETER P-LAM PANEL5 ---------------- - - DEM151N6 HALL 5TUO5 - DEM151NG HALL 61A5. TILE (MALL TILE) _ ------------- -- -------------GE ENTRY (PORCELAIN TILE)L ( FLOORIN6 (TOILET'ROOM): - VINYL SHEET - MEMBRANE _.....- ------------------------------- -- -- --- - MARBLE SADDLE ------------ ---------------- ------ -RE 51LIENT TILE / BA5E (5TOGK'ROO-M) FLOORIN6 (5ALE5 AREA) —RUBBER TILE ---------------- --------------------------------- --- ---------------------------------------------------------------------------------------------- - APHE51VE PAINTING STORE STOREFRONT ACRYLIC TILE 10 SPEC I ALTI ES ---------- _... - ---------------------------------- -- ------------------------- LOGKER5 SHOP -KIT TRAGK5 FiR5T AID KIT STORE ENTRANCE 516N5 FIRE EXTINGUI5-HER5, CABINET5, AGGE550RIE5 STORAGE 5HELV I N6: - FREE5TANDIN6 5TOGK-ROOM SHELVING - 5TOGK ROOM WALL 5TANDA-RD5 AND BRACKETS --------------- ---- - -- TOILET -ROOM AGGE55ORI E5 - GRAB BAR5, TOILET, LAVATORY t MtRROR N.N.OJ - D15PEN5ER5 D BRIGK ------------------------------------------------------------------------------------------------------------------------------------------------------- CORNER 6U/fiRD5 -------------- ---_...------------------ --- --- -- - - - - - FILTRATION 5Y5TEM CONTRACTOR LESO LANDL,0RP 5UBMITTo FURNISHED INSTALLED FMN15HM INSTALLED FURNI5HED INSTALLED REGV 0 0 ---------------------------- -- - - -- 0 0 0 0 --------------------------------------------------- --- - - 0 0 0 0 ------------- 0 0 0 0 ------------------ --------------------- -------- ----------- 0 0 0 0 0 0 ------------- ------------------------------ ------ --------- ------------- ------------------- 0 0 0 0 0 0 0 0 Rrz5P(;)N5151 L I T1' 5CHEPULE NOTE5 CSI DE50RIPTION PIVISION CONPITIONS OF THE CO TRACT 11 EQUIPMENT M15GELLANEOU5 EQUIPMENT: - SAFE - TAGKBOA'RD LOOSE FIXTURE5: - FREE5TANDING 5TORE FIXTURES LIVING ROOM FURNITURE --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- --------------------------------------------------------------------------------------- COORDINATE WITH MALL FAGILITIE5 MANAGER - PIGK-A-BRIGK MILLWORK COORDINATE WITH MALL FAGILITIE5 MANAGER - PERIMETER WALL VIN6 5HE AND BRACKETS (5ALE5) ALE5 COORDINATE WITH MALL FAGILITIE5 MANAGER 0 I LE60 TO SUBMIT A55EMBLY DWG. TO G.G. 0 0 0 0 0 0 --------- -------------- 0 0 0 ---------- --- - 0 --- 0 0 ----------- 0 --------------- ------ ------ 0 0 ------------------------- - 0 - 0 0 0 0 0 0 0 ---------- - - - - - - - - 0 - - -- - - - - - ------------------ ---------------- - ------ - ---------- ---- ------ - - - - - - -------------------- - - - ---------------------------- - - 0 0 0 0 0 G.G. TO SUBMIT TO DE516NER. ------------------------------ ----------------------------------- 0 0 0 6.G. TO SUBMIT TO DE516NER. 0 0 0 G.G. TO SUBMIT TO DE516NER. 0 0 0 6.G. TO SUBMIT TO DE516NER. o I o I I I I I o G.G. TO SUBMIT TO DE516NER. 0 1 0 0 0 -------------------- 0 --------- -------- 0 0 ---------------------- 0 0 0 G.G. TO PATCH AND'REPAtR A5-REQ'O. FOR FIRE`RATIN65 0 0 G.G. TO PATCH AND REPAIR A5-REQ'D. FOR FIRE-RATIN65 0 0 0 o ---------------------------- - -- 0 CONTACT MALL MOMT. FOR AVAILABILITY 4PRIGIN6 OF TILE ---- - --- - - ----------- -- - O.G. TO 5UBMIT TO DESIGNER. 0 0 0 G.G. TO SUBMIT TO DE516NER. 0 0 o 0 -------------- a ------------------------- 0 G.G. TO SUBMIT TO DE516NER. ---------------------------------------------------------------------------------------------------------------------- ------ O.G. TO SUBMIT TO DE516NER. 0 0 0 ----------- 0 0 ------- ----------------- 0 -------- ------- 0 0 ------ ----------------------- 0 0 1 0 64. TO 5UBMIT TO DESIGNER. 5EE 516N VENDORS SHOP DRANINS5 FOR DIMENSIONS 0 -- 0 --- — - -------------- ------------------ -----------6.G. -- - --- --- ---------------------------------------------- ------------------------ ------------------------------------------------------------------------------------------------------- TO A55EMBLE AND IN5TALL 0 0 0 0 IN TOILET ROOM 0 0 0 0 0 5UBMIT LE60 VENDOR 5UPPLIED 5HOP DWG5 TO LANDLORD 0 o G.G. TO A55EMBLE AND INSTALL 0 0 G.G. TO A55EMBLE AND IN5TALL -- —------------- 0 0 5EE A62 FOR INFORMATION 0 0 5EE A4.1 FOR INFORMATION o------------ ------- 0 ------------- --- -------- 0 ------------ - o --- ----0 --- --- ----------------- -- ---------------------- - -------------- - ------------------------------------------------------------------------------ PLUMBING CONNECTION BY G.G. 5EE PLUMBING OWG5 FOR INFO. 15- M ZHA ICAL FIRE PROTECTION- - SPRINKLER MAIN - 5PRINKLER 015TRIBUTION / HEAD5 / FIN15H ---------- ---------------------------------------------------------- - SPARE 5PRINKLER HEAD5 PLUMBING: - EXI5TIN5 5ERVIGE5 TO 5PAGE - EXTEND SERVICES TO NEW LOCATION ----------------------------------------------------- --- --------- - ------------------------------------------------------------- - -ROUGH - FIN15H - FIXTURE5 - WATER METER - TOILET EXHAU5T FAN HVAG: - AHU / GH / HW 5Y5TEM -- - -- -- - ----------- ---------------------- ------ -------------------------------------------- ---------- - DUCTWORK - GONTROL5 - DIFFUSERS AND 6RILLE5 ---------------------------------------------------------------------------------------------------------------- - 5MOKE DETECTION _ - ONE YEA1R 5ET OFIREPLAGEMENT FILTER5 - TE5TING, AD415TIN6, BALANGIN6 - BALANGE -REPORT 16 ELECTRICAL M15GELLANEOU5 ELEGTRIGAL: - METER BOX ------------------------------------------------------------------------------------------------------------------------------------ - METER - MAIN 5WITGH - CONDUIT TO LEASEHOLD - GONOUGTOR5 TO LEASEHOLD - ------------------------------------------------------------------------------------------------------------------------------------- - 0157 RIBUTION PANEL5 ------------------------------------------------------------------------------------------------------------------------------ - TRAN5FORMER -'RAGEWAY5, GONDUIT5, AGGE55ORIE5 - HIRE5 AND GABLE5 - DEVIGE5 AND COVER PLATES —_ - DOORBELL 5Y5TEM - FINAL ELECTRICAL HOOK-UP TO HVAG UNIT LIGHTING: EMERGENGY --- ------------------------------------------------------------------------------------------------------------------------------- - EXTERIOR - INTERIOR LAMPS: -EMER&ENGY - INTERIOR --- --- FIRE rt 5MOKE DETECTION 5Y5TEM TELEPHONE 5Y5TEM: - ----------------------------------------------------------------------------------------------------------------- - CONDUIT TO PREMI5E ----------------------------------------------------------------------------------------------------------------------- - EQUIPMENT - WIRING - DEVIGE5 - CONDUIT P05 DATA 5Y5TEM5: - EQUIPMENT - WtRIN6 --------------------------------------------------------------------------------------------------------------------- - DEVIGE5 -------------------------------------- -------------------------------------------------------------------------- - CONDUIT 1'U51G 5Y5TEM5: - EQUIPMENT - WIRING - DEVIGE5 - CONDUIT CONTRACTOR I LESO I LANDLiORJ7�BMITT, FURNISHED I INSTALLED I FURNISHED I INSTALLED I FURNISHED I INSTALLED I REQ'D 0 0 0 0 0 0 1 0 VT E : SE RAL Co TRACTOR To CooRPI ATE WORK WITH A Eso CONTRACTORS N NE N N ALL L N NOTE-5 6G TO IN5TALL PER LE60 PROVIDED PLANOGRAM o o I I EX15TINO TO REMAIN 1 o 1 SUBMIT (3) GOPIE5 WITHIN (1) WEEK OF START OF GON5TRUGTION 0 1 0 1 1 PROVIDED BY LANDLORD U) CL Z , I N � � s m Q z a F- � — � N L } o Q Q Z x O1 ~ — N N w ts) m_ Uui m - ------------------------------------ ----- ------ - ------ - - - - - -------------------- ------------------- - --- -------------------------------------------------- ----------- ------------------------------------------- --------------------------------------------- -------------------------- ------------ 6.G. TO SUBMIT TO DE516NER --------------------------------- — - 0 O.G. TO SUBMIT TO OE516NER 0 G.G. TO SUBMIT TO DESIGNER - . z 0 G.G. TO 5UBMIT TO DE516NER 5EE E4.1 FOR'REQUIRED 5UBMITTAL5 0 0 EXI5TIN6 TO -REMAIN 0 o EX15TINO TO REMAIN _ 0 o EXI5TIN6 TO -REMAIN 0 0 EX15TINO TO REMAIN 0 o �EX15TINry TO -REMAIN -------------------- ---------------------------- - 0 0 5EE ELEG. DH65. FOR NEW WORK IN PANELS 0 I 0 I I EXISTING TO REMAIN. PROVIDED BY LANDLORD CONDUIT 15 ALHAY5 REQUIRED - PROVIDE PULL 5TRIN6 CONDUIT 15 ALWAY5 REQUIRED - PROVIDE PULL 5TRIN6 CONDUIT 15 ALHAY5 REQUIRED - PROVIDE PULL 5TRIN6 vl��° F°R ODE COMP [� PtAGg G Alp _0 MpR 16 2015 ot, 0f �ukWila gul�plNG D IvISION RECEIVED CITY OF TUKWILA FEB 2 6 2015 PERMIT CENTER SHEET NO. A091 egress plan EXI5TIN6 ELECTRICAL SERVICES TO -REMAIN, SEE ENGINEERING DH65 FOR NEW WORK PROTECT EX15TINO STRUCTURE DURING DEMOLITION. MAINTAIN I HR FIRE RATING, TYP. ALL DEM151NO HALLS EXI5TIN(5 GORRIDgR O I LOCATION OF NEW MOP SINK. SEE PLUMBING DW695 FOR INFO. EXISTING TOILET ROOM TO REMAIN, PROTECT FIXTURES DURING DEMOLITION. -REINSTALL AFTER NEW FINISHES ARE INSTALLED. WE .. . I— w ... . . — rarer EXISTING 5TOGK'ROOM C) -------- - - - -- , - - - - - - - - - - - - I I I I I I I I I I I — — — — — — — — — — — — — — — 1 L--------------- I I SCALE. 1/4"= I'-O" LANI%O i; NOTES I. CONTRACTOR SHALL NOT DEMOL15H ANY ITEMS, INGLUDIN5 BUT NOT LIMITED TO CONDUIT, GABLES, DUCTS, ETC. THAT CONTINUE THRU THE TENANT SPACE AND DEM151NG HALL UNLE55 APPROVED BY MALL OPERATIONS. 2. CONTRACTOR SHALL MAINTAIN OPENING AT TOP OF DEMISING HALL TO MAINTAIN COMMON MALL -RETURN AIR PLENUM BETWEEN TENANTS. DRYWALL 15 TYPICALLY HELD DOWN FROM TOP OF HALL b" TO ACHIEVE RETURN PLENUM. RATING, TYP. ALL DEMISING HALLS PEMOL I TION NOTES: KEYED INTO PLAN D.I REMOVE EX15TINO STOREFRONT AND ENTRANCE DOORS A5 INDICATED. DO NOT -REMOVE BASE BUILDING 51MUGTURAL FRAMING. COORDINATE ANY WORK INVOLVING 5TRUGTURAL FRAME HITH BUILDING MANAGEMENT. DEMOL15H EXI5TIN6 CONCRETE 5UB-FLOOR A5-REG'D. SEE ELEG. AND PLUMB. DW65. FOR NEW WORK. REMOVE EX15TINO GA5HHRAP AND BASE CABINETS. SEE ELEGTRIGAL DHG5. FOR NEW ELECTRICAL HORK. PREP. GONG-RETE SLAB FOR NEW FLOORING A5 REO'D. -REMOVE ALL 5HELVING, SHELF SUPPORTS, 516NA6E, DECORATIVE MOLDING, ETC. PREP HALL FOR NEW SCHEDULED FINISHES AND INTERIOR HALLS. 5 EXI5TIN6 FLOOR MATERIAL TO BE -REMOVED DOHN TO CONCRETE 5013-FLOOR. PREP. 5UB-FLOOR TO-REGEIVE NEH FINISHES. EXISTING MALL TILE TO -REMAIN HITHIN AREA OF NEW STORE. b CONTRACTOR 15'RE5PON51BLE FOR PROTECTION OF MALL TILE AS REQ'D. DURING CONSTRUCTION. ANY DAMAGED TILE 15 TO BE REPLACED BY S.G. REFER TO DRAWING A3.1 FOR ADDITIONAL INFORMATION. EXI5TIN6 SALES FLOOR 0 CONTRACTOR NOTES I. VERIFY LIMITS OF DEMOLITION AND REGUIREMENT5 WITH LANDLORD. 2. COORDINATE ALL DEMOLITION WITH LOCAL MALL OPERATIONS MANAGER. 3. ANY RE -USED MATERIAL AND EQUIPMENT MUST BE-REFURB15HED TO A "LIKE NEW" CONDITION. 4. DO NOT ABANDON ANY UTILITIES OR MATERIALS WITHIN THE LEASE SPACE. 'REMOVE BACK TO THE SOURCE. 5. COVER RETURN AIR OPENIN65 BEFORE AND DURING GON5TRUGTION A5-REG'D. 6. PRIOR TO COMMENCEMENT OF CONSTRUCTION, PROVIDE TEMPORARY BARRICADE WITH DOUBLE DOORS PER LANDLORD'S INSTRUCTIONS. DO NOT FASTEN TO MALL FINISH MATERIAL. 7. -REPAIR AND/OR -REPAINT LANDLORD PROPERTY DAMAGED DURING TENANT IMPROVEMENTS PER LANDLORD 5PEG5 AND ACCEPTANCE. 5. GENERAL CONTRACTOR SHALL PERFORM A CALCIUM CHLORIDE TEST ON THE EXISTING SLAB AFTER DEMOLITION AND NOTIFY DE51ONER AND OWNER IF ADDITIONAL M015TURE MITIGATION 15 -REQUIRED. PROTECT PIER DURING DEMOLITION, 6G TO -REPAIR HALL AS REQ'D 1 , PROTECT MALL FEATURE COLUMN DURING DEMOLITION, 6C TO -REPAIR A5 REG'D PROTECT PIER DURING DEMOLITION, OG TO REPAIR HALL A5-REQ'D C ENERAL TOTES I. ALL HORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL NATIONAL, STATE, LOCAL CODES 4 ORDINANCES. 2. DEMOLISHED MATERIAL SHALL BE CON51DERED TO BE THE PROPERTY OF THE CONTRACTOR AND SHALL BE COMPLETELY REMOVED FROM THE JOB SITE, UNLE55 NOTED OTHERWISE. 3. THI5 DRAWING DOES NOT DEPICT THE FULL EXTENT OF DEMOLITION. ADDITIONAL ITEMS SCHEDULED FOR DEMOLITION MAY BE FOUND ON OTHER DRAWINGS. GENERAL CONTRAGTOR 15 RE5PON51BLE FOR THE COORDINATION OF THIS HORK WITH ALL PARTIES INVOLVED. 4. DEMOLITION CONTRACTOR MUST VERIFY LOCATIONS OF ALL EX15TINO STRUCTURAL, MECHANICAL, PLUMBING 8 ELEG-MIGAL ELEMENTS PRIOR TO START OF DEMOLITION. 5. REMOVE ALL INTERIOR HALLS 5HOHN DASHED. EXERG15E CAUTION 50 A5 NOT TO D15TMB OR DAMAGE ADJACENT SURFACES SCHEDULED TO -REMAIN. 6. 'REMOVE ALL PLUMBING FIXTURES 5HOHN DASHED. REFER TO PLUMBING DRAWINGS FOR -RELATED NEW WORK. T REMOVE ALL DOORS AND DOOR FRAMES 5HOHN DASHED UNLE55 NOTED OTHERWISE. &. IF, DURING THE COURSE OF DEMOLITION, ANY ASBESTOS MATERIAL IS SUSPECTED, ALL HORK 15 TO STOP IMMEDIATELY AND THE OWNER AND THE DE516NER ARE TO BE NOTIFIED. 9. 'REMOVE ALL FURNITURE, EQUIPMENT, HALL MOUNTED EQUIPMENT AND FIXTURES, FIRE EXTIN6U15HER5, HIRE RACKS 4 5TORA6E UNITS. O FIEIle p,NCE CDOsP f pVE® MAR 1 g Ims 1 0- uita Ctt l IVIS ON gU1l.D1NG D 10. -REMOVE ALL FLOORING SCHEDULED FOR DEMOLITION, INFILL ALL FLOOR PENETRATIONS PER LANDLORD 5PEG5 AND ACCEPTANCE. PREP. FLOOR FOR SCHEDULED FINISH. 11. GONTRAGTOR 15 RE5PON51BLE FOR PROTECTION OF ALL EXISTING ITEMS TO -REMAIN THROUGHOUT THE DURATION OF THE JOB. 12. ALL N015E PRODUGING DEMOLITION MUST OCCUR BEFORE OR AFTER NORMAL BUSINESS HOURS. CONTACT BUILDING MANAGEMENT FOR FURTHER DtREGTION. 13. GONTRAGTOR TO PATCH AND REPAIR DEMISING PARTITION AFTER DEMOLITION TO MAINTAIN-REG'D. RATINGS. RECEIVED CITY OF TUKWILA O z Q n 6 CQ Q Z E - Q —I w Lu zUx nwNw- t11 pLU V D--ryN(N N LLI 0 mom 00 rn t c LU z 15) 6.c in cc CD 0 M j. Ln 00 aj n0 cV rj h 9 LLJU F- ri- Fo - Z CD oQ N 0 LLj 6 rn Q FEB 2 6 2015 281 Farmington Avenue PERMIT CENTER I Farmington, CT. 06032 SHEET NO. DEMOLITION CEILING PLAN LEASE OUTLINE PLAN PROTECT EXI5TIN6 STRUCTURE DURING GON5TRUGTION. MAINTAIN FIRE RATING AT EXISTING DEMISING WALL, TYP. SENERAL NOTES I. ALL HORK SHALL BE PERFORMED IN 5TRIGT AGGORDANCE WITH ALL NATIONAL, STATE, AND LOGAL GODE5 AND ORDINANCES. 2. DO NOT SCALE DRAWINGS. THE GONTRAGTOR SHALL BE -RESPONSIBLE FOR OBTAINING CLARIFICATION OF DIMENSIONS FROM THE DESIGNER BEFORE CONTINUING WITH GON5TRUGTION. 3. GONTRAGT DRAHING5 MAY VARY FROM ACTUAL FIELD CONDITIONS. GONTRAGTOR SHALL CORRECT DIMEN51ON5 OF ALL MATERIAL5 TO GARRY OUT THE INTENT OF THE CONTRACT DRAHIN65. VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS IN FIELD BEFORE ORDERING ANY MATERIALS. GONTTRAGTOR SHALL NOTIFY DE51ONER PROMPTLY OF ANY CRITICAL DI50REPANGIE5 BEFORE PROGEEDING HITH HORK. 4. ALL NEH WORK SHALL BE IMPLEMENTED 50 A5 TO PROVIDE A SMOOTH AND CONTINUOUS SURFACE WITH ALL EX15TINO CONDITIONS. GON- RACTOR SHALL BE-RE5PON515LE FOR ALL WORK NECE55ARY TO ACHIEVE TH15-REQUIREMENT, EVEN THOUGH PROCEDURES ARE NOT DETAILED FOR EACH 5PEGIFIG CONDITION OR COMBINATION OF CONDITIONS, QUALITY OF HORKMANSHIP, MATERIALS AND FINISHES SHALL BE EQUAL TO THE LEVEL ESTABLISHED FOR 51MILAR CONSTRUCTION, EXCEPT WHERE EXISTING APPEARANCE 15 TO BE MATCHED TO ACHIEVE CONTINUITY. 5. GUTTING AND PATGHIN6 SHALL BE THE RESPONSIBILITY OF THE TIRADE HH05E HORKRE5ULT5 IN THE NEED FOR GUTTING AND PATCHING, UNLE55 A SPECIFIC CONTRACTOR 15 GALLED OUT ON THE DRAHING5. ALL HOLES LEFT BY REMOVING MEGHANIGAL, ELECTRICAL, PLUMBING EQUIPMENT , ETC., SHALL BE PATCHED. 6. ALL DIMENSIONS TO HEN GON5TRUCTION ON DRAWING AI.I ARE TO FACE OF GYP. BD., U.N.O. 7. ALL NEW DOORS ARE TO BE UNDERCUT A5 REQUIRED TO ACCOMMODATE FLOOR MATERIAL. & GONTRAGTOR 15-RE5PON51BLE FOR GOORDINATING WITH BUILDING MANAGEMENT THE DELIVERY OF MATERIALS AND ANY REQUIRED BUILDING 5HUTDOHN5 (I.E., FIRE SAFETY, HVAG, ELECTRIGAL, SPRINKLER, ETC) THROUGHOUT THE COURSE OF THE HORK. 9. CONTRACTOR SHALL CAULK AROUND DOOR FRAMES AND HVAG eRILLE5 BEFORE PAINTING BEGINS. 10. NO MATERIALS SHALL BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE THE METAL DECK ABOVE. CONTRACTOR 15 'REQUIRED TO BRAGE/SUPPORT ANY NEW HORK FROM 5TRUGTURAL STEEL IN TENANT SPACE. NOTICE TO CONTRACTOR RETURN AIR PLENUM PROTECTION REQUIRED (This only applies to those spaces that share return air plenums) Before any mail Tenant space Improvements or alterations are to begin, where plenum ceilings are removed, altered or return air ceiling grills are open/exposed to construction dust contamination, a "plenum protection plan" shall be required to show procedures and methods for protecting and sealing the return air plenums of any contamination from construction dust and combustibles prior to and during construction work. No inspections shall be performed until- mitigation procedures are made to protect any shared ceiling plenums. WALL T1OFE NOTE5 STOREr-RONT NOTES I. TYPE 'X' GYPSUM BOARD USED MUST BEAR THE U.L. I. USE ONLY THE FOLLOWING PRODUCTS BY G.R. LAURENCE GO., GLA551FIGATION MARKING. ING., FIN15H TO BE BRUSHED 5TAINLE-55 STEEL: SILL - 5R655538125L 2. FIRE CAULK ALL NON -FIRE -RATED PARTITIONS AND FILL VOIDS HEADER - NH255A240 WITH BATT INSULATION INGLUDING, BUT NOT LIMITED TO, FLUTES IN SQUARE GLASS CLIPS - ITEMS GRL MFG23 4 MFGIq ROOF DECK, PENETRATIONS OF DUGTHORK, ELECTRICAL *PROVIDE ALL ASSOCIATED MATERIALS. CONDUIT, PIPING, ETC. 2. MAINTAIN A GAP OF, " BETWEEN ALL SECTIONS OF 3. PROVIDE FIRE DAMPERS AT DUGTHORK PENETRATIONS IN ALL STOREFRONT GLASS. GLAZING GONTRAGTOR HILL BE FIRE RATED PARTITIONS. RESPONSIBLE FOR REPLACEMENT OF UNACCEPTABLE PRODUCT. 4. PROVIDE TREATED, CONGEALED HOOD/STEEL FOR ALL HALL 3. CONTRACTOR TO CONTACT OWNER'S LOCK VENDOR, MOUNTED ITEMS A5-REQUIRED. AMPHION/EXEGUTIVE SAFE AND LOCK, ® &00.520.2677. ALL HOU51N65 SHALL BE 'BEST' BRAND INTERCHANGEABLE GORE 5. GENERAL GONTRAGTOR MUST COORDINATE ALL -REQUIRED STYLE FOR 6 PIN. COORDINATE INSTALLATION OF OWNER ABOVE CEILING PARTITION PENETRATIONS WITH ALL ABOVE LOGK5 PRIOR TO HAND OVER. CEILING TRADES. 4. STOREFRONT GRAPHICS TO BE INSTALLED BY GENERAL 6. MAINTAIN I HR. FIRE RATING AT ALL DEMISING PARTITIONS. CONTRACTOR. 7. USE 189a. METAL FRAMING AT PoB HALL, SHELF BAYS, AND 5. GONTRAGTOR TO COORDINATE SIGN PERMITTING AND 51GN BOX YELLOW SOFFIT. ELECTRICAL INSTALLATION WITH OWNER'S SIGN VENDOR. 8. COORDINATE PLAGEMENT/SPAGING OF METAL 5TUD5 HITH ALL 6. GONIIRAGTOR TO CAULK BOTTOM EDGE OF ST. 5TL. SILL AT OWNER SUPPLIED SHELVING PRIOR TO INSTALLATION. 231%," STOREFRONT. COLOR TO BE GRAY. DIMENSION 15 APPROXIMATE. ' 1`M1VJh1VCIV I I CIV!" t1V I ' L-------------- J SCALE: 1 I/2"= I'-O" TYPICAL OF,2 NEUTRAL PIERS WALL TYPES AV METAL 5TUD5 ® 16" O.G. s /8II GYP. BOARD (BOTH SIDES) IA Va" GYP. BOARD ONE 51DE ONLY O Y2" GLEAR TEMPERED 6LA55 IN ST. 5TL. HEADER $ SILL ; DEMISING WALL O (2) 189a. 35/811 METAL STUDS INSTALLED BACK TO BACK 23131(1," O.G. 'RE: DETAIL 2/A7.1 y2" P-LAM PANELS ON 6" ISga FLAT STOCK ® 16" O.G. 3p Yam" GYP. BOARD IN LIEU OF)2" P-LAM PANELS op IANCE C pPPRO D MAR 16 2015 City of Tukwila sui,L NG WSION RECEIVED CITY OFTUKWILA FEB 2 6 2015 PERMIT CENTER 18ga. 3Va" METAL STUDS ® T6" O.G. 4 5/811 GYP. BOARD (BOTH :-- SIDES) FR. 2x4 HOOD BLOCKING ON 5ALE5 FLOOR 51DE 5/8' GYP. BD. METAL 5TUD5 INSTALLED BACK TO BACK 253,4" O.G. -RE: DETAIL 2/A7.1 )V P-LAM PANELS ON 6" 189a. FLAT STOCK ® I6" O.G. 6 Y2" GYP. BOARD IN LIEU OF Y2" P-LAM PANELS ga. 6" METAL STUDS ®I6" O. 6 I I O.G, HORIZ. rn: 0 Q mac. I. to I`» 10C rn I 9 Q r o w `U -- -- z z Nv ocnLLI c o sc N CLU Q Q T' LL ASSOCIATES INC. 281 Farmington Avenue Farmington, CT. 06032 SHEET NO. A1.1 EX15TINO GORRIDOR MEER G-4 EX TOILET ROOM 0 NORTH Rr=FLEGTED GE I L I NC PLAN SCALE: 1/4"= I'-O" C ENERAL GEILIN6 NOTE5 I. GEILIN6 HEIGHTS SHALL BE A5 NOTED ABOVE FINISHED FLOOR. GONTRAGTOR TO VERIFY ALL GEILIN6 HEIGHTS AND INFORM DE516NER OF ANY DISCREPANCIES. 2. REFER TO ELEGTRIGAL DRAWIN65 FOR L1614TIN6 FIXTURE TYPES, REQUIRED WORK AND FOR OTHER GEILIN6 MOUNTED EQUIPMENT NOT INDIGATED ON THESE DRAWINGS. 3. REFER TO MEGHANIGAL DRAWINGS FOR MEGHANIGAL FIXTURE TYPE5,-REQUIRED WORK AND FOR OTHER GEILIN6 MOUNTED EQUIPMENT NOT INDIGATED ON THESE DRAWIN65. 4. GONTRAGTOR SHALL NOTIFY THE DE516NER OF ANY CONDITIONS THAT PREVENT OR DELAY INSTALLATION. 5. GONTRAGTOR TO SUBMIT A GOORDINATED LAYOUT SHOP DRAWING INDIGATIN6 LOGATION5 OF ALL DIFFUSERS, 5PRINKLER HEAD5, 5PEAKER5, ETG. FOR -REVIEW AND APPROVAL PRIOR TO DUGTWORK FABRIGATION. 6. SPRINKLER 5UBGONTRAGTOR TO SUBMIT A LAYOUT SHOP DRAWING TO LANDLORD FOR REVIEW AND APPROVAL OF ALL SPRINKLER HEAD LOGATION5 PRIOR TO FABRIGATION. 7. MULTIPLE 5WITGHE5 AND/OR DIMMERS TO BE 6AN6ED TOGETHER IN GU5TOM PLATES A5 REaV. 8. GONTRAGTOR TO PROVIDE AN AIR BALANGE-REPORT FOR REVIEW AND APPROVAL. REPORT TO BE PREPARED BY AN INDEPENDENT GONTRAGTOR APPROVED BY THE INDEPENDENT AIR BALANGING GOUNGIL. q. SEE ENGINEERING DW65. FOR ALL FIRE ALARM WORK INGLUDING AND NOT LIMITED TO LOGATION5 OF ALL DEVIGE5 TO BE LOGATED/GOORDINATED WITH LOGATION5 OF LIGHT 5WITGHE5. 10. REFER TO ENGINEERING DWG-S. FOR ALL HVAG WORK INGLUDIN6 AND NOT LIMITED TO LOCATIONS OF DIFFUSERS (SUPPLY/RETURN), THERMOSTATS, ETG. THERMOSTAT LOGATION(5) TO BE GOORDINATED 4 ALIGNED WITH LIGHT 5WITGHE5. 11. CONTRACTOR TO GOORD. INSTALLATION OF ALL UN15MT 5EGONDARY SUPPORT TRAGK5 5EGURED TO PRIMARY BEAMS AND/OR TOP CHORD OF JOISTS A5 REQ'D. 12. CONTRACTOR TO INCLUDE ALL TE5TIN6, PROeRAMMIN6 AND FINAL CONNECTIONS REQ'D. TO TIE INTO BUILDING LIFE SAFETY SUPPORT AND CLASS E SYSTEM. 13. ELEGTRIGAL GONTRAGTOR TO AIM ALL LI6HT5 AS INDIGATED IN GONTRAGT DRAWING5. 14. WHERE HAN6ER5 GANNOT BE SUPPORTED FROM 5TRUGTURAL STEEL, INSTALL TWO DOUBLE EXPAN51ON SHIELDS GONNEGTED BY A 2 "x2" ANGLE TO SUSPEND THE HANOER-ROD. 15. 5PEGIALTY PENDANT LI6HT FIXTURE TO BE HUNG FROM GEILIN6 AT 4 POINTS BY AIRCRAFT WIRE. GONTRAGTOR TO PROVIDE METAL BLOCKING AT ATTAGHMENT POINTS. I& DIFFUSERS TO BE PAINTED TO MATCH ADJAGENT GEILIN6. 11. GOORDINATE AGGE55 PANEL LOGATION(5) WITH TENANT AND LANDLORD EQUIPMENT. COORDINATE LOCATION WITH DESIGNER. NOTE: FIELD VERIFY ALL GEILIN6 HEI6HT5 PRIOR TO INSTALLATION OF NEW GRID5. GOORD. WITH INSTALLATION OF LIGHTING FIXTURES, DUGTWORK AND EXI5TIN6 5Ti2UGTURE. NOTIFY DE516NER OF ANY GONFLIGT5 PRIOR TO INSTALLING NEW eRID. 0 6 n Q 2 z L6 11 z O0)ua ►zUp'= o>- LU } n Q-ry N Ui W U of t o GpMp'"j NGf_ CODE Mp,R 16 2a 5 C,tY of"u ila 11 av iNG Div, ipN .1 izEI-`LEGTE1: CE I L I NO LECSENC G-X GEILIN6 TYPE OS 5PEAKER I 0 XI-X" GEILIN6 HEIGHTUj o OV-0--V EXIT SIGN SEE ELEG. DWGS. FOR SPECIFIC TYPES. rn Q 0 SUSPENDED LIGHT FIXTURE. REFER TO ELEG. DW05. O *O SPRINKLER HEAD, -REFER TO ENGINEERING 5EGURE ALL THREAD SECURE GABLE TO DRAWINGS FOR 5PEGIFIG TYPES. "1 R EMEROENGY LIGHT FIXTURE. TO GEILIN6/SOFFIT GEILIN6/50FFIT REFER TO ELEG. DW65. ® SUPPLY DIFFU5ER. REFER TO MECHANIGAL FRAMING FRAMING ABOVE DRAWINGS FOR TYPES AND SIZES. TiZACK LIGHT FIXTURE. Ll REFER TO ELEG. OW65. RETURN GRILLE. REFER TO MEGHANIGAL DRAWINGS UNIVERSAL MOUNTING / STANDARD FOR TYPES AND SIZES. BRAGKET AND ELECTRICAL SPEC,IALTY PENDANT L16HT FIXTURE. FASTENERS OUTLET BOX 6FRG AGGE55 PANEL BY INTEXFORMS, REQUIRED RECEIVED O ALIGN ALL 5EAM5 TOWARDS REAR ElAT TENANT AND LANDLORD EQUIPMENT ABOVE CITY OF TUKWILA OF STORE. REFER TO ELEG. DW65. GYP. BD. GEILIN65. PAINT TO MATCH ADJAGENT GEILIN6 FINISH 0) B" 015 00 REGE55ED AG ENT LIGHT FIXTURE. REFER TO ELEG. DW65. 04 FIRE ALARM AUDIO/V15UAL 516NAL DEVIGE GANOPY PERMIT CENTER 281 Farmington Avenue LI6HT FIXTURE IN SOFFIT. Farmington, CT. 06032 REFER TO ELEG. DW65. GE I L I NC TYi=E 5GHEr%LE POWER GORD - SUSPENSION GABLES SHEET NO . n , STOREFRONT SIGN. L J PROVIDED BY OWNER. G-I GYPSUM BOARD, PAINT P-3 , ' L I I X T 6/ G 2 6YP5UM BOARD, PAINT P 2 G-3 EX1 LAY -IN CEILING TILE ^ 'j / OUN7 I 'I I e 7 j I- INNIrA A2.1 G 4 EXISTING CEILING ' l I_ I I j, J' t 5GALE: 3"=1'-O" I. 5PLIGE5 AND INTERSECTION OF RUNNERS SHALL BE ATTACHED WITH MECHANICAL INTERLOGKING CONNECTORS SUCH AS POP RIVETS, 5GREW5, PINS, PLATE5 WITH BENT TABS, OR OTHER APPROVED CONNECTORS. DE51ON CONNECTORS FOR 2X DE516N LOAD OR ULTIMATE AXIAL TENSION. CR055-FURRING SHALL BE SECURELY ATTACHED TO THE MAIN -RUNNER WITH NOT LE55 THAN ONE STRAND OF NO. 16 OR TWO STRANDS OF 15 U.S. GAUGE TIE WIRE OR APPROVED EQUIVALENT ATTACHMENTS. 2. RUNNERS AND FURRIN6:THE MAIN'RUNNER AND CRO55-FURRING SHALL COMPLY WITH GBG D05A. 3. A HEAVY DUTY T-BAR GRID SYSTEM SHALL BE USED. 4. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE GEILIN6 GRID SHALL BE ATTACHED TO THE CL05URE ANGLE. THE OTHER END IN EACH HORIZONTAL DIREGTION SHALL HAVE A 035 IN, GLEPARANGE FROM THE WALL AND 5HALL�RE5T UPON AND BE FREE TO SLIDE ON A GLO51JRE ANGLE. 5. SPRINKLER HEADS AND OTHER PENETRATIONS SHALL A 2" OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE GEILIN6 TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST I" IN ALL HORIZONTAL DtREGTION5. ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE I OF GEILIN6 MOVEMENT IN AL HORIZONTAL DIRECTIONS 15 PERMITTED TO BE PROVIDED AT THE TOP OF THE SPRINKLER HEAD EXTENSION. 6. HANGER FOR SUSPENDED GEILING5 SHALL COMPLY WITH GBG D03A, A5TM G635, A5TM G636 AND A5GE 7-05. HAN&ER5 SHALL BE SADDLE TIED AROUND MAIN RUNNERS TO DEVELOP THE FULL 5TREN6TH OF THE HANGER5. 7. 12 GAUGE GALVANIZED HANGER WtRE5 4'-0" O.G. MAXIMUM ALONG MAIN -RUNNERS. MAIN'RUNNER5 WIRE 5PLIGE5 ARE PROHIBITED. PROVIDED GOUNTER 5LOPIN6 WIRES WHERE ANY HANC7ER WtRE5 ARE MORE THAN I IN 6 OUT OF PLUM. 8. PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT 055TRUGTION5 TO MAIN HANGERS. q. FASTEN HAN6CR WIRES WITH MINIMUM OF 3 FULL TURNS, 1 1/2" FROM BOTH EN05 OF WIRE. LATERAL BRAGING WIRES TO BE FASTENED WITH A MINIMUM OF 4 FULL TURNS 1 1/2" FROM ENDS. 10. ALL 12"X24" GEILIN6 LIGHT FIXTURES AND HVAG'RE615TER5 SHALL BE SUPPORTED INDEPENDENTLY WITH A MINIMUM OF (2) #12 GAUGE WIRES AT OPPOSITE CORNERS. THE GEILIN6 SUSPENSION SYSTEM SHALL NOT SUPPORT OTHER ITEMS. II. SPREADER BARS OR OTHER APPROVED SYSTEM 15-REQUIRED TO PREVENT THE PERIMETER GRID FROM 5PREADIN6 APART AT THE UNATTACHED WALLS. 12. FOR THE ATTACHED WALLS, THE GEILIN6 GRID TO BE ATTACHED TO THE WALL MOLDING, THE GRID 15 NOT TO BE ATTACHED TO THE WALL MOLDING FOR THE UNATTACHED WALLS. GYPSUM BOAR: � GF. I L. I NCB NOTES 50ALE: NONE HANGER WIRE CRO55 TEE / CHANNEL MAIN TEE SPLICES AND INTERSECTION OF -RUNNERS SHALL BE ATTACHED WITH MECHANICAL INTERLOCKING CONNECTORS SUCH AS POP RIVETS, SCREWS, PINS, PLATE5 WITH BENT TABS, OR OTHER APPROVED CONNECTORS. DE516N CONNECTORS FOR 2 X DE51ON LOAD OR ULTIMATE AXIAL TENSION. CR055-FURRING SHALL BE SECURELY ATTACHED TO THE MAIN -RUNNER BY SADDLE TYIN6 WITH NOT LE55 THAN ONE STRAND OF NO. 16 OR TWO STRANDS OF NO. 18 U.S. 6AU6E TIE WIRE OR APPROVED EQUIVALENT ATTACHMENTS. SUSi=ENDEr;> CE IL I NO 5GALE: NONE FASTEN TO TOP CHORE OF EXISTING J015T MIN. 3 TIGHT FULL TURNS IN 3' AT END OF WIRE, TYP. 12" 6AU6E VERTICAL 6ALV. HANGER WIRE MIN. 3 TIGHT FULL TUI 3' AT END OF WIRE, . HEAVY DUTY MAIN'Rl 5/8" 6YP5UM BOARD HANC ER W I RE =>EiA I L 5GALE: I FASTEN TO TOP ' -A CHORD OF EXI5TIN6 J015T MIN. 4 TIGHT FULL TURN5 IN 3' AT END OF WIRE, TYP. 12" 6AU6E 45' GALV. 13RAGIN6 WIRE MIN. 4 T16HT FULL TUR 3' AT END OF WIRE, T HEAVY DUTY MAIN'RUI 5/5" 6YP5UM BOARD 5GALE: 1 1/2"= I'-O" 1/4" PIA. EYE SCREW WITH I" MIN. EMBEDMENT 8" M/ r]6r]1►ICT /1 /V'I.1r9C A\I --1 = /cT']/l/'/.fll 1\1\I- -Al A - ♦IA 1\I�t•911\I\IRI"1 NOTES I. SEE DETAIL 3 FOR DETAILS AT GEILIN6 PERIMETER 2. SUSPENDED GEILIN6 STRUCTURAL SUPPORT FOR VERTICAL AND LATERAL LOADS, AND DETAILS FOR CONNECTIONS, AND LATERAL SUPPORT SHALL BE PER A5TM G635 AND A5TM G636; A5GE 7 SECTION 13.5b. 3. LIGHT FIXTURES INSTALLED IN 5/5" GYPSUM BOARD SHALL BE SUPPORTED DtREGTLY FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE WITH A MINIMUM 12 GAGE KIRE5 PER 2506.2.1; A5TM G636. LEGEND x 12 GAUGE VERTIGAL HANGER WIRE • ATTACHMENT OF -RUNNERS TO GL05URE ANGLE TYP I GAL SUSPF.NI7ED GE I L I NC PLAN LAYOUT SCALE: NONE MIN. 3 TIGHT ' ' TURNS IN 3 A WIRE END, TYI #12 6A. VERT HANGER WIRE 4'-O' ALONG MAIN'RUNNER MAIN14 NNER 45 DE6.5PLAY WIRE BRACING IN PLANE OF MAIN'RUNNER. ALL WIRES ATTAGHE12 TO MAIN 'RUNNER (4) OtRECTION5, TYPICAL CRO55'RUNNER SPLICE NOTE: DETAIL TO BE USED WHEN�REQUIRED BY LOCAL JURISDICTION SPLAY BRAG I NC 50ALE: NONE 8" MAX. m 8" MAX. 11 12 GAUGE VERT. HANGER H MIN. 3 TIGHT FULL TURNS IN 3" AT EACH WIRE END 5/8" 6YP5UM BOARD l:_ M i:_ • V# l ATTAGH`RUNNER TO GL05WE ANGLE AT ONE END 2' MIN. PLRIMTER CL05ME ANGLE, TYP. #12 50REW5 AT EACH 5TUD WOOD OR METAL STUD WALL " GAP 2" MIN. I_ I./ - ATTACHED UNATTACHED GE I L I NC FERNETER SCALE: 1 1/2"= I'-O" WEB FOR RE CQMptLjANCf- COp� RQv — On App I MAR 16 201 Cif o�-Tu"i►a 6 RECEIVED CITY OF TUKWILA FEB 2 6 2015 PERMIT CENTER w U D C p c LO dL ca LO US OC1 q� C�0 LO N o F6 L w F zzLU ... C— +d z -' cn z w� ct N W 281 Farmington Avenue Farmington, CT. 06032 5HEET NO. A2s2 SAFETY FLOOR TAPE INSTALLED ON FLOOR AT ELEGIRIGAL EQUIPMENT EXI5TIN6 GORRIDOR TOILET ROOM -taxv2XV2 io a. V I. a i J. wmrvc m GUARD, TY ALL OUTSIDE CORNERS IN 5TOGK-ROOM - WWW.THEGORNER6UARD5TORE.COM ITEM #G6-S54-18481.5-qO • ^ "_ _11.111 _d.111 I - A Ll -- -1- GLl/lOY1T T.O A rl/ OCr1=GGCPI CONNECTION BENEATH GA5HWRAP5. SEE ELEG. PRAWINC75 FOR ADDITIONAL INFORMATION. TO ALIGN WITH OUTSIDE EDGE OF SOFFIT ABOVE BRA55 FLOOR BOX, SEE ELEG. DW65., CENTER IN -RUBBER TILE, TYPICAL OF 2, GOORD. LOCATION WITH OWNER'5-REP. 0°oc 0° O0 0° 00 OOC_ 1 0° 1 00 00c. 1 1 o - 1 1 0 0 k 00C. ,1 1 goo 1 00 1 1 1 00c 1 0 1 00 o0c. c O 0 o 0 000°00100 ENTRY 00o<->oC o c oo1 O°OOUDOOc 0 0 0 0 0 00000000 MT-1 O0O0 otoc 00000000 0 0 0 0 0 0°0 ' 0J0°c ,:< :<: 0 0 3 0 0c o°o 1 1 o°c o°c 1 1 1 000 / 1 1 0 0-0 0 0 0 0 0 0 . OR O F NG JOID P 16 p 5 MPS o ,,' NORTH I SCALE:I/4"=1'-O" 6 x4g0 C ENERAL NOTES I. ALL FINAL APPROVAL OF FINISHES TO BE DETERMINED BY 0E516NER AND OWNER. NOTIFY OWNER5'5 REPRESENTATIVE OF ANY DI5GREPANCIE5. CONTRACTOR TO PROVIDE SAMPLES AND PRODUCT DATA OF ALL FINI5HE5 PRIOR TO INSTALLATION. 2. CONTRACTOR SHALL PAINT OR FIN15H ALL NEW AND EXISTING DOORS AND FRAMES A5 REO'D. CONTRACTOR TO PAINT ALL AREAS WITHIN AREA OF WORK AS NOTED ON CONTRACT DRAWINGS. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY UNACCEPTABLE FLOOR FINISH WORK CAUSED BY POOR 5UB-FLOOR CONDITIONS AND IMPROPER PROTECTION OF FINISH FLOOR MATERIAL AFTER INSTALLATION 4. PAINTING CONTRACTOR TO OBTAIN APPROVAL OF FINISH GOAT FROM DESIGNER AND OWNERS REPRESENTATIVE. 5. REFER TO ELEVATIONS FOR WALL FINISHES WHEN MORE THAN ONE FIN15H 15 USED. 6. ALL WALL OUTLETS 4 SWITCH PLATES TO BE WHITE FINISH. U.N.O. 1. UPON COMPLETION OF THE WORK THE CONTRACTOR SHALL -REMOVE FROM THE PREMISES, ALL WA5TE MATERIALS, RUBBISH, HRAPPIN65, ETG. A5 GENERATED BY THE FIN15H MATERIALS. 8. ALL "EXISTING TO -REMAIN" SPACES SHALL HAVE ALL WALL5, FLOORS, AND GEILIN65, MADE GOOD AND SMOOTH, TO -RECEIVE FINISH. q. FLOORING CONTRACTOR TO VERIFY CONDITION OF 5UB-FLOOR PRIOR TO FINISH APPLICATION. 10. CONTRACTOR SHALL CAULK AROUND DOOR FRAMES AND HVAG eRILLE5 PRIOR TO PAINTING. 11. ALL WALL AND GEILIN6 FINISHES SHALL HAVE A MAXIMUM FLAME SPREAD -RATING OF 'GLASS I'. 12. CONTRACTOR SHALL 5GRI13E WOOD BASE TO FLOOR TO MINIMIZE 6AP5 BETWEEN BOTTOM OF BASE AND'RUBBER TILE FLOOR. 13. RUBBER TILE FLOOR INSTALLED BY CONTRACTOR PER MANUFAGTURER'5 -REGU I REMENT5. 14. INSTALL 30 mil POLYETHYLENE GLEAVAGE MEMBRANE IN ALL NET AREAS. MEMBRANE MUST EXTEND A MINIMUM OF 4" UP WALL. 15. CONTRACTOR SHALL CAULK TRANSITION BETWEEN WOOD BASE AND RUBBER TILE FLOORING. 16. ANY RE -USED MATERIAL AND EQUIPMENT MUST BE'REFUR13I5HED TO A "LIKE NEW GONDITION. 11. FLOORING GONIRAGTOR SHALL PROVIDE A CALCIUM CHLORIDE TEST OF CONCRETE SLAB 24 HOURS PRIOR TO INSTALLATION. TEST TO BE PERFORMED BY AN INDEPENDENT TE5TIN6 AGENT. FINISH NOTES I. EXISTING MALL FLOORING TO REMAIN. CON- RAGTOR TO PROTECT DURING GON5TRUGTION AND REPLACE ANY DAMAGED FLOORING. 2. ALL FLOOR FINISHES TO EXTEND TO WALL AND OR BASE OF GA5EWORK. 3. FIN15H PLAN SHOULD BE USED IN GONJUNGTION WITH FINISH SCHEDULE. SHOULD THERE BE ANY DISCREPANCIES BETWEEN INFORMATION GIVEN ON THE FIN15H/GOLOR SCHEDULE, AND ANY OTHER DRAWINGS IN THE SET, THE HIGHE5T QUALITY FINISH SHALL BE PROVIDED. 4. PAINT DOOR CHIMES TO MATCH COLOR OF WALL. 5. CONTRACTOR TO CAULK BOTTOM EDGE OF ST. 5TL. STOREFRONT SILL AND WOOD BASEBOARD. 6. AFTER IN5TALLATION,-RUB13ER TILE FLOORING TO BE PROTECTED WITH REINFORCED GON5TRUGTION PAPER AND/OR MA50NITE SHEETS A5-REQUIRED PRIOR TO GLEANING, WAXING, AND TURNOVER. 1. RUBBER TILE FLOORING TO BE INSTALLED PER MANUFACTURER'S -REGOMMENDATION5. AFTER INSTALLATION, CONTRACTOR 15 TO FOLLOW MANUFACTURERS APPROVED FLOOR GLEANING AND 5EALING TO ENSURE A PROPER FINISH PRIOR TO TURNOVER TO THE OWNER. RUBBER TILE TRANSITION SCHEDULE 5GHULTER 5GHIENE METAL STRIP ZING DIVIDER 5-RIP FOR FLUSH JOINT MALL TILE VGT RUBBER TILE '- 505FLOOR LEVELER 5Y5TEM THRESHOLD TH- 5CALE:NONE ALUMINUM THRESHOLD, MAX 2:1 SLOPE FRAME WIDTH ry THRESHOLD TH-5 5CALE:NONE THRE5HOLI:; TH-2 5CALE:NONE DOOR I VINYL SHEET FLOORING 6 FRAME WIDTH L THRESHOLD TH-4 5GALE:NONE MARBLE THRESHOLD, MAX 2:1 SLOPE SCHEDULED FLOORING 1= I N 15H SCHEDULE FLOOR I BASE I WALL5 z O 'ROOM NAME 001 ENTRY MT -I -- -- 002 SALES FLOOR RT-1,2 W13-1 P-1,2' 003 5TOGK-ROOM EP, VGT-I 'R5-1 P-1 004 TOILET -ROOM 1 V5-1 V5-I I P-1, FRP COLOR LE ENi;l o z :ABINETS MISC. ry 6 o z 0. W W 11-I fu to y- to 0 ? v Q < Qo < z z - w z(b O- v v OLU-0 D P-I >. FL -I Y P-1 Y Y <- m ry M P-1 [ Ll -ryryry FLOORS T1 RUBBER TILE FLOORING: •I■■j -RT-I .JOHN15ONITE 24"x24" WEATHERED FINISH TILE CUSTOM YELLOW - PANTONE 116 -RT 2 JOHN50NITE 24"x24" WEATHERED FINISH TILE GREY EPDXY FLOORING: EP-1 PPG AMERCOAT - AMERLOGK 2 VOG VINYL COMPOSITE TILE: a VGT-I ARM5TRON6 SAFETY ZONE U STANDARD COLOR 51005 SOFT BEIGE VINYL SHEET FLOORING: rw V5-1 JOHN50NITE OPTIMA HOMOGENOUS SHEET FLOORING #664 (GONGRETE SLAB) MALL TILE: MT-1 MATCH EXI5TIN6 MALL TILE HALL BASE RUBBER WALL BASE: _RB-I JOHN50NITE #4q BEIGE WOOD BASE: W15-1 I"x4" FR. BIRCH Y2"ROUTER ALONG TOP EDGE, PAINT P-1 WALL PAINT PAINT: P-1 BENJAMIN MOORE (WALL5, DOORS, FRAMES 4 WOOD TRIM) SEMI-6L055 WHITE - INTERIOR -READY MIX P 2 BENJAMIN MOORE (SOFFIT, DIFFUSERS, 4 GEILIN6) SATIN 1 2021-30 SUNSHINE NOTE: PROVIDE LEVEL 5 FINISH P-3 BENJAMIN MOORE (GEILIN6) d FLAT w WHITE - INTERIOR -READY MIX CA M15G 1 ° FIBER6LA55 REINFORCED PANEL: FRP 5EGUENTIA 5TRUGTO DEGOR-TEXTURED - SILVER (0066) PLASTIC LAMINATES: PL- I WIL50N ART (MANAGER'S DESK) ALMOND LEATHER - 2g32 Q: ACRYLIC PANEL: 0; AG-1 PLEXI6LA5 MG ACRYLIC GLADDIN6 (INDIVIDUAL TILES) ..c WHITE a 'RE: DETAIL 3/A8.1 zill RECEIVED CITY OF TUKWILA FEB 2 6 2015 r [ PERMIT CENTER , ` - cry :r FINISH L=S NO W o Z z = oT ww - C( J i ao ri LL' 111 RUBBER TILE VINYL SHEET ---- ---- (RT) 5-) 1 1 1_1__1 I .1 PORCELAIN TILE n (PT-1) 281 Farmington Avenue Farmington, CT. 06032 SHEET NO. A391 "j r-- ]/ M/,%^KA GL:CI %I:AIG 48"06" 48"x48" 48"x48" CHANGE 1 1 PROTECT EXI5TIN6 5TRUGTURE 111, M 6'-0,V4" ItC'S 1 11 (1 DURING GON5TRUGTION. I CLEAR w 11 1 1 5HOPKIT TRACK zo GUT TO 4'-O". 5EE 1 `v 48"x36" 48"x48" 48"x48" � TWIN rAC,4-FWRAP NOTES BELOW. 1 � _- E. GC FILTRATION 5Y5TEM PROVID AND INSTALLED BY OWNI INDICATES MANEUVERI CLEARANCE REQUIREMEIS IN ACCORDANCE WITH A NORTH V) DKtINU `CID !11`Rl '0ML_V 1 r*4V rr-K EXTINGUISHER CABINET, 5EE GENERAL NOTE #3 OWNER. REACH HEIGHT AT 48" EXTINGUISHER CABINET, 5EE ELEVATION5 ON 5/A7.1 AND GENERAL NOTE #5 A.F.F. MAX. SEE ELEG. DW675 GENERAL NOTE #5 MANUFACTURER'S 5TANDARD5 FOR ADD'L INFO. I=UiZN I TURE $ �= I XiURE! PJ.,4N 5GALE: I/4"= I'-O" TOILET ROOM ACCESSORIES ** AGGE55ORIE5 ARE PROVIDED AND INSTALLED BY CONTRACTOR UNLE55 NOTED OTHERWI5E. 5EE ELEVATIONS ON Ab.2 eRAB BAR5 MANUFACTURER: BOBRIGK ITEM #: 5-5506 MOP 51NK FAUCET MANUFACTURER: 5TERN-WILL I AM5 ITEM #: T-10-VB MOP HANGER MANUFACTURER: 5TERN-WILLIAM5 ITEM #: T 40 TOILET TI55UE D15PEN5ER MANUFACTURER: CA5GADE5 ITEM #: 7842N PAPER TOWEL 015PEN5ER MANUFACTURER: GA50ADE5 ITEM #: 353-164 50AP 015PEN5LR MANUFACTURER: DOJO ITEM #: 756787 5ANITIZER 015PEN5ER MANUFACTURER: PURELL ITEM #:23g287 SEPARATE STORAGE RACK PERMIT REOUIRED All rack storage fixtures over 5'-9" high shall be installed under the provisions of a separate storage rack building permit. All rack storage fixtures greater than 8-feet high shall have the method of anchorage/bracing designed by a professional engineer. Periodic special inspection is required in all cases during the anchorage of racks over 8-feet in height. Special inspection requirements shall be specified on the rack permit plan. I. GG TO OBTAIN ALL NEGE55ARY INSTALLATION 6UIDE5 FROM 64 N INOU5TRIE5 FOR PROPER IN5TALLATION OF 5HOPKIT GABLE 4 TRACK. 2. IN5TALL 5HOPKIT TRACK IN GEILING WITH MECHANICAL FASTENING SYSTEM THAT HILL 5UPPORT A 5U5PENDED LOAD OF 50 POUNDS. 3. U5E ONLY ZING PLATED FLAT HEAD FA5TENER5 FOR INSTALLATION OF 5HOPKIT TRACK, GOUNTER SINK TRACK A5 REQ'D. 5. IF -REQ'D, PRE -DRILL HOLES IN 5UB-FLOOR, FILL HOLE5 WITH 2 PART EPDXY, THEN INSTALL 5HOPKIT TRACK IN FLOOR BEFORE EPDXY HARDEN5. 6. PROTECT INSTALLED 5HOPKIT TRACK FROM FOREIGN MATERIAL AND FLOOR TRAFFIC DURING GON5TRUGTION. 1. PRIOR TO INSTALLATION OF GABLE5, GG 15 TO IN5TALL A 2" 5EGTION OF FULLY YZEGE55ED "U" CHANNEL AT EACH END ALL SHOP KIT TRAGK5. 51ZE AND FIN15H SHALL MATCH 5HOPKIT TRAGK5. 8. GONTRAGTOR SHALL A55EMBLE AND IN5TALL FOUR (4) 5HOPKIT CABLES PER TRACK. cl. 5EE ADDITIONAL STOREFRONT DRAWINGS AND NOTES ON A6.1 AND AS.I. 10. GUT 5HOPKIT TRACKS TO LENGTHS INDICATED ON THI5 DRAWING. SHOPK I T CABLE 4 TRACK NOTES PIG. I P91-TRAG< -GRUB SGREN -SNIVEL MOUNT o -END STOP PIC-7. 2 END STOP GRUB -• SGAZEN PIG. 3 a � TEN51ONER - GABLE PIG. 4 ., 'OPEN' _ GENTRAL TENS IONER BARREL - LOG< NUT -i SNIVEL MOUNT B GOMPLETE A55EMBLY INSTALLATION OF TRACK • F16. I: 5EGURE TRACK TO GEILING 4 FLOOR U61140 #6 50REH5. PROVIDE FR. 2X4 BLOGKING IN GEILING A5 NEEDED. IN5ERT CORRECT NUMBER OF TRAGK 5W I VEL MOUNTIN05 A5 REQ'D. • GABLE, END STOP 4 TEN51ON5ER PREP: MEA5URE FROM FLOOR TO GEILING THEN 5UBTRAGT 5%," AND GUT GABLE TO THAT LENGTH. • FIG. 2: IN5ERT GABLE INTO END STOP (T15.2/T5.1) MAKING SURE THE GABLE PA55E5 BEHIND BOTH GRUB 5GREH5 THEN TIGHTEN 5EGURELY. • FIXING GABLE TO TRACK: INSERT GABLE END STOP INTO GEILING 5WIVEL MOUNT AND TIGHTEN GRUB 5GREH AGRO55 TO 5EGURE. • FIG. 4: MAKING 5URE TEN51ONER 15 FULLY OPEN, IN5ERT INTO FLOOR SWIVEL MOUNT AND TIGHTEN GRUB 5GREH AGRO55 TO 5EGURE. • ROTATE CENTRAL BARREL OF TEN51ONER TO TEN51ON GABLE. 5EGURE P051TION OF BARREL U51 NG THE (2) LOCKING NUTS. • DO NOT OVER -TIGHTEN PICTURE PANEL OR SHELF GRIP5 A5 THIS MAY DAMAGE GABLE. 5HOPKIT TRACK, OUT TO 4'-0". 5EE NOTE5 BELOW. GENERAL NOTES I. CONTRACTOR TO PROVIDE FIRE RETARDANT BLOGKING A5 REQ'D FOR ALL WALL MOUNTED FIXTURE5. 2. CONTRACTOR TO PROVIDE AND IN5TALL RlveTier II 5OLTLE55 STORAGE TO 10'-0" WITH 5HELVE5 ® 18 20". ANCHOR SHELVING UNITS TO FLOOR, WALL AND ADJACENT 5HELVING UNIT5 IN ACCORDANCE WITH LOCAL 5EISMIG REQUIREMENTS. CONTACT eRREG C7ARR15ON AT 636A5&.7100 ext.221 TO ORDER MATERIAL. ALLOW MIN. 3 4 WEEK5 FOR DELIVERY. 3. GONTRAGTOR TO PROVIDE AND IN5TALL 51X TIER, 12"w X 12"h X 15"d G-THRU METAL LOGKER5 BY TENNSGO, MODEL # GBL6421512-G. 4. INSTALL -RED BRIGK FIXTURE AFTER IN5TALLATION OF FLOORING. PROVIDE (4) 1" DIA. HOLE5 ALIGNED WITH BOLT5 IN BRICK UNIT. FILL HOLES WITH 2 PART EPDXY AND 5ET BOLTS INTO HOLE5. APPLY CLEAR 100% 51LIGONE ADHESIVE BETWEEN BASE PLATE AND FLOOR. PROTECT UNIT UNTIL EPDXY 5ET5. 5. FIRE EXTINGUISHER GA13INET AND FIRE EXTINGUISHER BY JL INDU5TRIE5, INC. OR APPROVED EQUAL. G.G. TO PROVIDE AND INSTALL GA13INET WITH OPTIMUM REGE55 DEPTH GIVEN WALL CONDITION. 6. ATTACH PIGK-A-BRIGK BAR TO GONCRETE 5LAB A5 INDICATED IN DETAIL ON A4.1 PICK -A -BRICK BAR :;>ETA I L REVIEWED FOR CODE COMPLIANCE APPR MAR 16 2015 City of Tukwila BUILDING DIVISION ATTACH PIGK-A-BRICK BAR TO 5LAB WITH POWDER ACTUATED FA5TENER5, PROVIDE FR. WOOD BLOGKIN5 A5 REQ'D. r-I XTURE AND CASHNRAP NOTES I. PERIMETER FIXTURE5 TO BE 5UPPLIED BY LEGO VENDOR AND INSTALLED BY GONTRAGTOR. ARRANGE FOR DELIVERY AND ACCEPTANCE OF ALL MATERIALS. COORDINATE SPACING OF WALL 5UPPORT5 WITH FIXTURE5 PRIOR TO STUD INSTALLATION. 2. GA5HWRAP AND PaB FIXTURES TO BE SUPPLIED BY LEGO VENDOR AND INSTALLED BY CONTRACTOR. FIXTURES TO ARRIVE IN MULTIPLE PIEGE5. DO NOT INSTALL P-LAM. GABINET5 UNTIL DELIVERY OF ALL FIBERGLASS 5URROUND5. 3. GONTRAGTOR TO CAULK JOINTS BETWEEN FIBERGLASS 5URROUND5 WITH CLEAR AGRYLIG CAULK AND JOINTS BETWEEN P-LAM. 5URFAGE5 WITH WHITE ACRYLIC CAULK. 4. ADDITIONAL 5ALE5 FLOOR FIXTURE5 TO BE SUPPLIED BY OWNER. CONTRACTOR TO COORDINATE ARRANGEMENT AND I145TALLATION WITH OWNER. RECEIVED CITY OF TUKWIL,A FEB 2 6 2015 6 z $ _-7-� ' Q X J _W 7 < Q/ } O I] Q N z :< 0 VIOL}�� > p�?ryryry _ N !' 0 H 4-Jo UJ W qQ �' aw U o Jl W F_ Zz = o WW 0¢ M �► W < ...: L LL- C<L o w rn U) 10 Z�l 281 Farmington Avenue Farmington, CT. 06032 SHEET NO. A401 BOOR 51SHC>ULE DOOR 7Yi=E5, EL VATION5, :;>ETAIL5 - o Q DESORIPTION N } o OF NORi< DOOR FRAME HARDNARE 9 INDIGATES REQUIRED NORK q) L z � � 51ZE FIRE GORE AGGE551BILITY w < 3 < } o � IJ� 6' �„ � a �.y 1r 6'-0" L1 Ll IY L XV o zZ o O O W = 12"W PEEPHOLE — (}/ N 0 / \ GLAZING 11 AT 60" N W �I1 i X — On �- v-A 2 Q to W / \ 3 O 3 O A.F.F. 3 O VARIE5 LU � W ��/ I— D- z J J� z j� W Q z O �n z 0- / / \ \ - a� / / \ O LU Z 0 — 1LI 11I 1Li (� I— O W W Q < O / \ O u z J z w \ / o - / - \ J _ - _ _ i' Q tL K � �-- O \ / ,n u) u) — Q Q (i/LU < z J� z W= v / o 0 0Jmryry zzpJ LU 111 LU o7—z WWzo Q Q - ,� >L ���oJ�N= -REMARKS 6L-I HM-I HM-Z HM-3 HMP-I 001 (2) 3'-0" 10'-0" GL-I -- -- -- -- a -- 2/A3.1 PROVIDE.5 KEYS "'ExISTIN6 DooR, 002 3'-0" 7'-0" HM-I HMF-I I/A5.1 2/A5.1 P-1 b -- 3/A3.1 PROVIDE FACTORY PAINTED WHITE 12"N FRAME //�� MW HARDWAREOld 003 +♦ 3'-0" 7'-O" HM-3 HMF-I I/A5.1 2/A5.1 P-1 d -- 5/A3.1 PROVIDE 5 KEYS �V I` TYPES 004 3'-0" 7'-0" HM 2 EX EX EX P-1 c 45 MIN. 4/A3.1 PROVIDE 5 KEYS PEEPHOLE 5GA1..E: 1/4'-1'-0" HARCV�IARE 5GH�UL MOUNT ON LATCH # # / SIDE OF DOOR 5FEGIFIGATION NUMBER DESGRIPTION A u 5 a 5,5, q, 10, II, 12, 13 I BUTT HINGES: TA2714, 41's"x4�", U5320, McKINNEY 2 a \ `a - b I, 4, 5, 6, 14, 17 2 NOT USED. _�, PAINTED HM. \ ' CAULK ALL SIDES � \ c I, 4, 7, 15, 16, 17 (ALL HARDWARE 3/4 HR. RATED) 5 LATGH5ET: AL405 NEP, TW15T LOCK, 626 5CHLAGE I NORTON ALUM O DOOR FRAME \ \ UNISEX d I, 3, 4, 5, 16 4 CLOSER- 550 BF, w (2) 35/8' MTL. STUDS 5 DOME STOP: ROCKWOOD #460, 626 FIN15H (WITH EXTENDERS A5-REQ'D) AT HEAD PROVIDE SHIM AND ALL 51GNAGE SHALL COMPLY WITH ADA AGGE551BILITY GUIDELINES: 6 51LENGER5: CLEAR NEOPRENE R 7 FIRE RATED RIM EXIT DEVICE: #V40-F-EB, DETER, 626 FINISH > ANCHOR STRAPS AS�REQ'D. w I. LETTERS AND NUMERALS MUST BE RAISED )" FROM SIGN SURFACE. 8 (2) DEAD BOLT, BOTTOM RAIL MOUNTED W/ THUMB TURN, BEST GORE b-PIN - O N O 2. CHARACTER HEIGHT MUST BE AT LEA5T 5/a" AND NOT MORE THAN q (2) 10"H BOTTOM'RAIL, BRUSHED 5TAINLE55 STEEL, G:R. LAURENCE DRI05B512GL = 2 MTL. STUDS � I6 O.G. 10 (2) 24" VERTICAL BACK-TO-BACK PULL, TWRU Ys' TEMPERED GLA55, G7z. LAURENGE GM24X24B5, ®RUSHED STAINLESS STEEL FINISH, CENTER AT 36" A.F.F. W/ 5/6" GYP. BD. 3. TYPE STYLE FOR LETTERS AND NUMERALS SHALL BE 5AN5 II (2) 5TAINLE55 STEEL TRAN50M PATCH 4 PLATES SET, DORMA UNIVERSAL, 626 FIN15H EACH 51DE VARIES SERIF OR SIMPLE SERIF. 12 (2) FLOOR-GONGEALED DOOR CLOSERS, DORMA #BT575V F.R. WOOD BLOGKIN6 PAINTED H.M. 4. WORDS AND NUMERALS MUST BE CONVERTED INTO GRADE 2 AS REOV. DOOR FRAME BRAILLE AND BE APPLIED TO SIGN. 13 (2 PAIR) DU5TPROOF STRIKE #570,-ROGKWOOD, 626, INTTALL IN OPEN AND CL05E POSITIONS 14 b"W xlb"H PUSH PLATE,`ROGKWOOD #70E 4 12"xl"4) VERTICAL PULL WITH CONGEALED HARDWARE,-ROGKWOOD #GIOCI, CENTER AT 56" A.F.F. 5. VERBPIGTOAL DE5 SHALL BE ACCOMPANIED BY THE EQUIVALENT I a T �,i A VERBAL DESCRIPTION PLACED DIRECTLY BELOW PIGTOORAM. 15 SMOKE 6A5KET5: #MGK544, McKINNEY .JAMS �E 1 A I L nEAC> ETA I L 6. AGGE-55151LITY 516N5 SHALL BE AN51 APPROVED, E.5. PLASTIC, I6 WALL BUMPER: #406 U532D,-ROGKWOOD I 5cALE:3"=1'-0' 2 5cALE.3'=r-0" NEMA-RATED, 5ELF-EXTIN61J15HIN6, 4 ADHESIVE MOUNTED. 17 24"x34" 5TAINLE55 STEEL KICK PLATE: #KI050-5A, ROGKWOOD O TA o im F{,EVIE�O FOR .IANGE COD�pp p1 VD MAR 16 2015 Gy INO DIVIS losZ BUILD e O WUzi LO RECEIVED x 2opp' CITY OF TUKWILA Uj,,,_ 01. +J Lo FEB 2 6 2015 WOO PERMIT CENTERo v� cy 19 DOOR 51 C NAC E HARDWARE r; OOR NOTE5 w ~ Z w a= n cn-- i E5 S I. DOOR #004: 2"RED VINYL TAPE WITH WHITE LETTERS I. ANY DOOR SCHEDULED FOR RE-U5E SHALL BE RETURNED TO A 11. CONTRACTOR SHALL VERIFY ALL WALL THIGKNE55E5 PRIOR TO TENANT NAME 'LIKE NEW' CONDITION. CONTRACTOR SHALL NOTIFY OWNER OF ORDERING AND FABRIGATING ANY NEW DOOR FRAMES. SPACE # ANY 155UE5 THAT WOULD PREVENT -RE -USE. w 12. ALL DOORS SHALL BE 13/4" THICK, U.N.O. t 2. TENANT SPACE NUMBER WITH 4" WHITE VINYL LETTERS - 2. PROVIDE (1) ONE 'MA5TER' KEY THAT OPENS ALL LOGK5 (3 CA) GOPIE5). 13. LOCATED BOTTOM RIGHT CORNER OF STOREFRONT 16 ALL DOORS SHALL PROVIDE MINIMUM J" CLEARANCE BETWEEN A.F.F. BOTTOM OF DOOR AND THRESHOLD (OR FLOOR) TO PERMIT FULL COORDINATE FINAL LOCATION WITH TENANT COORDINATOR. 3. PROVIDE SEPARATE 'MASTER' KEY FOR ALL LOCKABLE DOOR 5WING. FIXTURES. � 14. CONTRACTOR SHALL VERIFY ACTUAL DOOR HEIGIT-REQ'D FOR n/ 4. CONTRACTOR TO INSTALL AND KEY ALL LOGK5ET5. DOOR FRAME SYSTEM. LL 5. EXIT DOOR IN STOCK ROOM TO BE CONNECTED TO BUILDING'S 15. ALL EXIT DOORS IN 5TOGK-ROOM TO HAVE SIGN AT 46" AFF GLASS E SYSTEM AS REQ'D. PROVIDE ALL EQUIP. A5YZEQV TO WHIGH-READ5: "THIS DOOR TO -REMAIN UNLOCKED DURING MEET BUILDING STANDARDS. GOORD. WITH BUILDING BUSINESS HOURS." MANAGEMENT. I6. PROVIDE DOOR AND FRAME ASSEMBLY WITH APPROPRIATE 6. DO NOT ATTACH DECORATIVE FINISHES TO FIRE -RATED DOOR LABEL FOR USE IN WALL WITH-REQ'D. RATING A5 NOTED ON V— AND FRAME A55EMBLIE5 THAT WILL COMPROM15E THE FIRE SCHEDULE. ASSOCIATES INC. RESISTIVE INTEGRITY OF THE ASSEMBLY. 17. WHEN IN FULLY OPENED POSITION, DOORS SHALL NOT-REDUGE 7. ALL F1RE-RATED DOORS SHALL BE 5ELF-GL051N6 4 THEREQV EXIT WIDTH BY MORE THAN 4". P051TIVE-LATCHING WITH SMOKE GA5KET5. 281 Farmington Avenue 16. ALL KEYINGY?EQUIREMENTS ARE TO BE COORDINATED WITH Farmington, CT. 06032 6. CONTRACTOR SHALL VERIFY ALL DOOR HADWARE WITH OWNER'S OWNER, g REP PRIOR TO 5UBM155ION OF SHOP DRAWING-5. q. CONTRACTOR SHALL GOORD. DOOR/HARDWARE ANDREQ'D. Iq. ALL HARDWARE TO HAVE SATIN 5TAINLE55 FIN15H 626, U.N.O. CS. HE-r=" I' NO. SECURITY HARDWARE. 20. CONTRACTOR TO INSTALL ALL DOOR HARDWARE EXCEPT FOR 10. CONTRACTOR 5HALL SUBMIT DOOR AND HARDWARE SHOP CYLINDERS. DRAWIN65 AND HARDWARE PRODUCT DATA/5AMPLE5 TO 21. CONTRACTOR TO COORDINATE TENANT IDENTIFICATION 516NAGE DESIGNER FOR APPROVAL PRIOR TO FABRICATION. REQUIRED AT BACK DOOR WITH LANDLORDS ON -SITE Mel ]C- $TAMVE EXI5TING MALL COLUMN. MALL FIN15H MATERIAL ON MALL COLUMN FACE. G.G. TO COORDINATE WITH MALL'REPRE5ENTATIVE. PROTECT DURING GON5TRUGTION. O m 0 / 00000 a 3 4 STOREFRONT A7.1 5167N, 5EE A8.1 A7.1 FOR DETAILS EQ. 2* WHITE ACRYLIC INDIVIDUAL TILE5, 5EE DETAIL 3/AD.1 FOR INFO. ----------- - 1 CONTINUE PATTERN ON > > l RET N5. 5EE 3/A5.1 FOR 0 00 c 0000 00000 STOREFRONT ELEV'AiIDN 5GALE: 1/4"= I'-O" FRAMELE55 ED&ELIT EXIT 516N, BOTTOM AT 5'-O" A.F.F. PAINT P-1 BEHIND PaB WALL INTERIOR ELEVA7I0N 5GALE: 1/4" = I'-O" 3/4" F-R. PLYWOOD BLOCKING IN51DE WALL ON ALL SIDES 23/8"cD 5TEEL FLOC MOUNT SUPPORT LEc ON EITHER 51DE c 5Af M�N?C �R'S 17�SIG ELEVAiI0N 5GALE: GYP. BOARD, PAINT P-1 5QUARE 5T. 5TL. GLIP5, TYP. AT ALL 5EAM5 ADDRE55 IDENTIFICATION; COORDINATE WITH MALL -REPRE5ENTATI VE. 8" m DEGAL5, APPLIED TO INSIDE FACE OF GLA55. CONTINUE PATTER ON RETURNS -RE:-1/A6.1 FOR PaB WALL FRAMING 4 WIRING INFO ATE: FIXTURE LAYOUT 15 FOR DIAGRAMMATIC PURP05E ONLY. GONTRAGTOR TO INSTALL FIXTURES PER OHNESR PROVIDED LAYOUT. ALL FIXTURES TO BE INSTALLED FLUSH/IN 5AME PLANE. PAINT HALL5 P-1 5URFAGE MOUNTED 5TANDARD5 INSTALL PRINTER DIRECTLY ABOVE 5AFE NEW COUNTER 8 BAGK5PLA51-1, PL-I UNDER COUNTER 5AFE, PROVIDED BY OWNER, INSTALLED BY CONTRACTOR WITH (4) 3/8" EXPAN51ON ANGHOR5 DRILLED INTO 5LAB 2 A7.1 II I I I II - - --------------------------------- - - - - - - - - - - - II II I II II II moo mmmm LEXAN CORNER GUARDS, 5EE A3.1 FOR INFO. INiERlOR ELE\lAilON 5GALE: 1/4"= I'-O" PRODUCT 5HELVINC, PROVIDED BY OWNER, CONTRACTOR TO IN5TALL PER OWNER PROVIDED LAYOUT. 2 GYP. BD. 5OFF I T, A7.1 PAINT P 2 5 A7.1 151M. GU5TOM-RING LIGHT FIXTURE, PROVIDED BY OWNER, GONTRAGTOR TO INSTALL, 5EE 2/A2.1 FULLY-REGE55ED FIRE EXTINGUISHER CABINET, CENTER AT 36" A.F.F. 2TE: FIXTURE LAYOUT 15 FOR DIAGRAMMATIC PURPOSE ONLY. GONTRAGTOR TO IN5TALL FIXTURES PER OHNER PROVIDED LAYOUT. ALL FIXTURE5 TO BE IN5TALLED FLUSH/IN 5AME PLANE. Q� •• •• •• mm mmm •• •• •• •• •• •• — 0---------- - 1 A7.1 O.H. 7ERIO L Y A710N 5GALE: 1/4"= I'-O" N�A I Ae I5 5 5C7 I ON 5GALE: 1/2"= I'-O" POWER 4 DATA LOCATED ON BOTH 51DE5 OF 5TORE, 5EE E 1.1 FOR INFO. BRAND RIBBON 4 PICTURE FRAME GABINET5, PROVIDED BY OWNER, CONTRACTOR TO IN5TALL PER OWNER PROVIDED LAYOUT. ATE: FIXTURE LAYOUT 15 FOR DIAGRAMMATIG PURP05E ONLY. GONTRAGTOR TO IN5TALL F I XTURE5 PER OWNER PROVIDED LAYOUT. ALL FIXTURES TO BE INSTALLED FLUSH/IN 5AME PLANE. ...... 0 _.._ HHITE MELAMINE FACED 5HELVE5 FITTED WITH WHITE SPUR BRAGKETRY ....., ..._ _ 5URFAGE MOUNTED 5PUR .. ...,� UPRIGHT ® 24" O.G. . � PROVIDE FR. BLKG. AS __ it _ RQD .......... - ---- - - - ------_-- ---- 24"xl-1/2" COUNTER WITH-- - „ - ._...... _ (2) GABLE: MANAGEMENT {, it INSERTS _ _ ------ ..,. HATCH INDIGATE5 , 0 0 0 CLEAR ADA AGGE55 dJ - P—LAM. 5UPPORT LEG, _%' _%' �._._ A5-REQ'D + ' f$R. 2x4 BLOGKING, O PAINTED P-1 - P I CeiG—A—BR I GIG WALL WIRINC =>ETAIL 5GALE: 1/2"= I'-O" RgV1EVVE•D FOR CODE COM yip CE APPRO MAR 16 2015 City of Tu VISION BUILila DING D TO PANEL "LP" I" E.M.T. CONDUIT BEHIND PIGK-A-BRICK BINS DUPLEX RECEPTACLE, WFRE TO PANEL "LP" CIRCUIT #q DUPLEX -RECEPTACLE, WIRE TO PANEL "LP" CIRCUIT #II DUPLEX RECEPTACLE, HFRE TO PANEL "LP" GIRGUIT #q -RECEPTACLE, HIRE DUPLEX TO PANEL "LP" CIRCUIT #11 DUPLEX -RECEPTACLE, WIRE .. TO PANEL "LP" GIRGUIT #q I'-OI, GG TO INSTALL PaB WALL RECEIVED CITY OF TUKWILA ou'jHREB 2 6 2015 IT CENTER 5HEET NO. A691 -WHE . . . . . . n � z CL 5TOGK ROOM < E Ab.2 < L_ z wad z LO 0 7F X _j LU FILIRATION 5r5TEM PROVIDE AND > < 'R. N/0111 1,11101, ks) Ex IN5TALLEV BY ONNE 5EE PLUMBINO ON65 PAINT P I PAINT P-1 FOR NEP4 HORK 5b"xbO" CLEAR 4011 NEN MOP 5INK, 5EE - Uj q) FLOOR 5PAGE 15" x V4'V VERTICAL PLUMBIN6 OW-55 FOR - - - - - - AT TOILET. INFORMATION. '1`11 6RA5 BAR, PEENED. IL 56"Ap4"O 6RA13 BAR, PROVIDE PEENED Uj 42"44'4 eRAB BAR, 'j TOILET NEP4 epRAB BAR5. FINI!5H PROVIDE PEENED FIN15H bO" 0 CLEAR ROOM 5EE ELEVATION5 FLOOR 5PAGE FOR CODE GALL FOR Ab�2 COMPLIANCE. AID TOILET T155VE _711 U_ r D15PEN5ER. 5EE AA.I 0 FOR INFO. .. .. ... ..... T-1 'X' .. . ... ... . ... 30"x4&" CLEAR FLOOR L K":* 5PAGE AT LAV. . . . . . . . . . . . . . . EXISTINCV TOILET 11 1 IX Q 311 411 COVE MAINTAIN ACGE55113LE-��� �48 -EX15TINC7 TOILET LAV TOREMAIN.—J BA5E, V5-1 CLEARANCE AT LAV PROTECT DURINO GON5TRUGTION. PER AN51 1111. RETURN TO "LIKE-NEN" CONDITION 70 1 L-E7 ROO�� 004 701L.E7 ROCY 004 70LE7 ROCY 004 ENL.AfRISEr:> FLAN 5GALE: 1/2"=P-011 All, ADD -R. 4 PAINT P-1 Y2" r -PLY -- ------------------ PLYPqOOD FRAMIN6 IF NOT EX15TIN& MIRROR 4 ALIC7N NITH 5OFFIT PAPER ABOVE; PAINT P-1 5ANITIZER D15PEN5ER TONEL AND PROVIDED BY ONNER 50AP 015PEN5M IN5TALLED BY O.G. PROVIDED BY OMER, IN5TALLED BY O.C. E - R A5.1 FOR DOOR 4 HEADER INFO MOP HAN C-7[---R ON ... .... .... . ---- ------- ---- ----- ADJACENT HALL 13OVE - ------- A MOP 5INK. TOILET 5TOGK ROOM ROOM MOP 5INK FAUCET - ------------------------------------------------------------------------------------------------- --------- - --- 0 pow. c00 MOP 5INK. 5EE PLUMB. EX15TINC7 LAVATORY; 01466. FOR INFO. PROVIDE PIPE H13-1, PAINT P-1; CAULK 0% CE IN5ULATION COVER. NOTE: REFER TO DN& BOTTOM ED 6E, CAULK TO A4.1 FOR ALL TOILET BE NHITE. Oil ROOM AGGE5WRIE-5 701L.r=7 ROON� 00.4 Fa5 AALL 570CK ROO�� 005 ELEVA710N SE r::�F.7A I L 4 ��LIJ 5GALE: 1/2"=V-011 i2DO .01 eN MALL FIN15H MATERIAL ON MALL COLUMN FACE. O.G. TO COORDINATE HITH :5; G, MALLREPRE5ENTATIVE. LO., A6.1 3: N' Q0 A6.1 LLJ +4-3'-0" V.If. YARIE5. \,/ARIQ LU CD F_ z 11 all 411 E3 0 ----- ---------- ----------- ----- --- - ---- --------- --- < :D LL_ A(b.1 fly --------- - ----- — - - ------ ---- ia� Ld -6ce --------------------------------------------- PATCH AND -REPAIR EX15TINC7 C7YP. 5D COLUMN ------ --------- ---- -- - --------------- --- ENGL05URE. PREP FOR IIL"Al ---- ----------- I - -------- ----- - -------------- ---- NEP4 FIN15HE5. A > -P4HITE ACRYLIC- - - ------------------ ---- GLADDINC-7 5EE - -- - ------- 31Ab.1 FOR IN5TALLATION _NHITE ACRYLIC GLADVINC-2-- ---- ---------- ----------- ---- -------------------- ---- INFO. ONNER Arb.1 5EE 3/A&.1 FOR ----- ----------- PROVIEA=-[?# ----- - - - ---------- ---- IN5TALLATION INFO. 5EE CONTRACTOR ---------- - -------- 1415-1, PAINT P-1; CAULK FR. 2x4 BLOG<INC7 AT END ELEVATION5 ON qIA62. IN5TALLED. 130TTOM EDOE HALL, RETURN TO 5HELF -- - ---- ------ -------------------- 5TANDARD 4 PAINT P-1 U_ FR. 2x4 BLOGKIN6, HB-I, PAINT - IN15TALLED UPRIOHT FR. 2x4 BLOGKINC7 LEXAN CORNER CGUARD, P-1; CAULK RN ----------------- R R ASSOCIATES INC. V.I.F. L.^.' I I %.,M ALL GORNE'R5, 5EE A3.1 A E06E 5 G V.I.F. FOR INFO. NOTE: VERIFY ALL DIMEN51ON5 IN THE FIELD. RECEIVED 281 Farmington Avenue A CITY OF TUKWILA Farmington, CT. 06032 1=RC*"S>UC7 �NALL AW ACR)OOL I C., FEB 2 6 L 2015 SHEE7 NO. BABE r::�F.TA I L Arb�2 COLLNN ELEVATION5 PERM ENTER F AAi 5GALE: I/2"=I'-O" 5GALE- A6.2 QL r III GYP. BOARD I n I N .v ..:. ... ..1 , / ... ,... Ji' : ,:.... .i .., , .f / :...... .....:..: ..:.». ,........ :...:,::v-,:., r:,:,:,:::;l::`::<,.ii:>:::«:::i:::::t<i :tr s:"t ::r:.<:t::%::`> :33::'•-,t[ :::::.<„°: :r: s'>;r:i:;::ii::ii::i::i::i::i;::<%l'; ;itrti:.:::>::z:z i : ii:: °3i '::: ::'t:: <<::<:::ii:: :.','-..<:,-:-.-{.:.::;.,.:,.:.,r..< : <i.,< i3:f :<:: :.,:.»::: r, i ri::ir , r . , ..i..:.......,:. ,. : ,.... Jl i.......... .......... ice.:....i . : i i /... i /:i. i-,! .. .v J. .,,' .. .... .,....i.i ..... .... .,......... i,.v. ,. .. .,. .,:... .::,...v.,.:...»:::.I. .... :.. :...:..::::... .....,.. ,..nF.:,:,,....v ..,!`/». ::.:i^;,: .,. ,:,'E":':`<..; :: > >s>::::#::3:°`s: > '/i`w :.. ..... .. ...... :....... ......., ...... „ ..,.:i/.,.:....._:.,:,,,,:,.,::,:.».,:,,,,,«.... ::. .. ..::.», .:,,:.. >Idl.l.,. it i : `i " ''t v. .. .. .... ....... „ ii ., ,, ,' . ,.,.... .... ,......, ... v:i:. .... :.......::... v J........:,i%,........ .. ,....:.. .: .J.. J!/ . i i ..i4— ... i: ' iJ i.. .,/.1.,i.><.>.>;;«: <::,::./v , / v. . .o»..:..:. / i v''vv i....,.................:.... :. .... ........ i ,., ......,.... v;..,., ... .............. .. ... .,.iiv .:J .:.:, <......:. .::ii` , '.. ,i v is v, it J J / , J ....:::.:......_ ::.../ J:':., i , 3 METAL STUDS 8 — I h i \ 7` ------------------------------------------- — -- ----------------------------------------------------------------------------------------------------------------- ----------------------------------- I ------------------------- ----------------------------------------------------------------------------- 'rc' % %/ I I I 5/8' FRY RE6LET 5GREE (l Q O AU6N ALL ' '` ` << I GHANNEL # DG5-625-50 Z !1J v F:f'. ` EX MOUNT ® 8' 2" A.F.F. W _ VERTIGAL SEAMS .<> ;' ,.:...... I I I- ------------- -- - ------------------------ TOWARDS -REAR r- -T-,-- six/, fff<` I METAL TRAPPING Q I I I I I I OF SALES FLOOR ;` y i II I I .\ / _ 1 3625162-43 GONTINUOU5 I I EXTEND METAL „ GHANNEL 4 HORIZONTAL i I I FRAMING TO ` •` I 1 Y P-LAM PANELS Y8' AIRGRAFT i' i' i I i' i' I >% ------ ---- Z Z _ STUDS W/ 4-0.1454? PONDER II UNDERSIDE OF GABLE, TYP. 2 i II SCALE: 6 _ II_ Z DRIVEN PINS TO UNDERSIDE IOI IOI 5TRUGTURE ABOVE — WPER PENDANT LU — ~ Ul I I . i i I „ OF EX. JOISTS. \ \ I I I I I FOR BRAGIN6LIGHT FIXTURE ; i I I 11 3625162-33 DIAGONAL ` BRAGIN6 ®32" O.G. W/ /8 . . 6YPBDGEILIN6 . I I I 1 y': 5 ` I I I I I , ATTACH METAL 1 .' i' ii (4) #10 TEK SCREWS PERu- INSTALLED ON 13/8" DRYWALL GYP. BD. ON 5TOGK 51DE STUDS TO y ii GONNEGTION SUSPENSION SYSTEM, PAINT TO 12'-b" TO MAINTAIN UNDERSIDE OF P 2. SEE NOTE BELOW FOR i i-------------- i I -RETURN AIR PLENUM EXI5TIN6 ' '. I - 11, 1 ».. — ::... v I PAINTING INSTRUCTIONS 1 STRUCTURE ;/'. ----------------------- ---- --- ------------------------- -- I h ABOVE. IA I " 35/8" METAL FRAMING 6 189a METAL FRAMING ® O 4 /e GYP. BD. ® ve", GYP. BD., <' SOFFIT W/ 5/8" GYP. BD, PAINT SOFFIT, PAINT P-I. PAINTED P-I. 6 b % p P 2. SOFFIT 4 GEILIN6 REQUIRE p ----- . MINIMUM OF 4 GOATS OF PAINT SEE ELEG. DWGS. OVER YELLOW TINTED PRIMER m Y2' MDF GAP AT TOP » FOR LIGHTING TO AGHIEVE FULL GOVERA6E. 6 OF PaB WALL ONLY USE ROLLCR W/ SHORT PAINTED P-I, A FIXTURE INFO. ,. KNAP. OWNER'S REP AND MEMO, ARGHITEGT MUST APPROVE 4 FINAL FINISH GOAT.USE JBga METAL FRAMING AT POB 5GREED GHANNELcl wi O - WALL. REVEAL MOLDING f..' _ T====_== :n ----D E---- 1 1 " , :?....,: I ®8 2 A.F.F. II ; „ PaB BINS, PROVIDED SALES FLOOR SALES FLOOR _ BY OWNER ---_ ` J r 3v INSTALLED BY CONTRACTOR. " ^ . : : .f1 11 :.% J J lf VV77 = ILL .............. _ tLl ------------- ----------------- - BRAND RIBBON -----__ 11 GONTRAGTOR TO 'r' rQ, p _-----'--- GASES AND // PAINT WALL P-I q] ... SHELVING PROVIDED 6G TO INSTALL SILVER - ----- <. BY OWNER; INSTALLED L_ S_ ----- BEHIND PaB BINS RINGS FOR PICK A BRICK BY G.G.. GUP D15PEN5ER5. PRIOR TO BIN EXISTING 1I I f_ I INSTALLATION. DEM151N6 WALL` " f< ~ ~ -----J TO -REMAIN. — in S }a= — — I PICK-A-BRIGK BAR, _ I! O1 PROVIDED BY OWNER ----- — — INSTALLED BY m m O O GONTRAGTOR. _----- 'j /` '` 'j 5 GA5HWRAP, GA5EWORK AND 7 I I TIDE R I `./ R B C I 1 O I {I 6 I I III7 R I O R B C 7 1 0 I III BY ON LA55 SURROUND PROVIDED 6 BY OWNER, CONTRACTOR TO INSTALL. 5GALE: 1/2"= I'-O" i 3625162 43 CONTINUOUS ATTAGH TO UNDERSIDE f O OF EXI5TINC 5TRUGTURE I>;: ; , GHANNEL 4 HORIZONTAL ABOVE. %%F STUDS W/ 4-0.145 ~ w ------------------ - ---- -- j--------- - - - - - - - - T.. - POWDER DRIVEN PINS. —I - -------- ---- FOR ------------- C\ -----------1-----/ - = V B.O. BULKHEAD ELEV. = 15 -O A.F.F. I. 1.. I I I p►p \---------- —------------ [ l 3625162-33 DIAGONAL BRACING ® I ? `. ` i Ii12► 32" O.G. W/ (4) #10 TEK 5GREW5 PER p GONNEGTIONNG p V c ' N 0, ______--------=1=== ---- _____ B.O.50FFIT ELEV. = 12'-O" A.F.F. U.J. , I 0 A8.1 c 6 2 STOREFRONT HEADER, SEE 3/A,5.1 FOR INFO. I 1 t:O 5 '. / I'-I113iiy" GAULK PANELS ® 50REED GHANNEL Ili 4 L SQUARE 5/5 GLAZING CLIPS, i I 5HOPKIT GABLES. SEE A4.1 FOR TMP' .00 MOLDING. ..................... . ............. U INFORMATION. 4V. TYPIGAL AT ALL SEAMS (BEYOND). INSTALL WALL STANDARDS AT EAGH DOUBLE STUD LOGATION. VERIFY HEIGHTS W/ OWNER. PROVIDED BY g Y2 CLEAR TEMPERED GLA55 I I I CLEAR TEMPERED GLA55 ' . r. _ OWNER; INSTALLED BY G.G. 1 J zo + (BEYOND). i:::, ..: w INSTALL MOF. PANEL W/ WHITE PLAM. fW- = z z f BE SCREWED ,. GLOSS FINISH. PANELS TO - INTO DOUBLE METAL STUD w `` - i z SALES FLOOR ENTRY MALL .0 IV I I I CONSTRUCTION. PROVIDED BY OWNER; a o w 002 ooi O I INSTALLED BY G.G. °- I— 5ALE5 FLOOR MALL a, a X LA i i II 0—C 01 __j OO OO OO .G. TO INSTALL BRAND RIBBON — m „ ,,,i , G B TS PROVIDED BY OWNER• Y2 CLEAR TEMPERED GLA55 VE RIFY LOG ATION O I I I WNER. DOOR W/ FLOOR GLOSLSR. ,. .. ....- - W/ 10 STOREFRONT SILL. i A ELEG. OUTLET, SEE ELEG. DW -6. FOR LOCATIONS. N 5/5 #4 BRUSHED FIN. FLOOR L.L GHANNEL. CAULK BOTTOM EDGE. I I I OEM. ; i '. .:.>. GAULK TO BE GRAY. A8.1 — — — — i —11—: —i — — — HATCHED AREA INDICATES FLAT V" — - -: - STOGK FASTENED TO METAL >: -- ., LINE OF NEW FIN. FLOOR. I :' > i.. ASSOCIATES INC. J .':x FRAMING. SEE ALI FOR WALL TYPES. --------------j ''` ' 281 Farmington Avenue RECEIVED Farmington, CT. 06032 CITY OF TUKWfLA N7ERIOR 5 G71ON I Nfi RI OR 5 C71ON I N7 I O L V 710 SHEET NO. FEB 2 6 2015 C NfiRY 570R r-RON7 @ 5 5 FLOOR NTER [y 9 11_ 1 11 _ I II SCALE- I/2"=1'-0" (D 5GALE: I/2 - I -O SCALE: I/2II-I -O A79 l FIRE PROTECTION PLA SCALE: 1/4"= I'-O" W FIRE PROTECTION NOTES 1. DRAWINGS ARE DIAGRAMMATIC AND SHOW ONLY SPRINKLER LOCATIONS. 2. ALL WORK SHALL BE PERFORMED PER CURRENT APPLICABLE STATE CODES, NFPA 13 STANDARDS, AND PER LOCAL FIRE MARSHAL AND OWNER'S INSURANCE UNDERWRITER REQUIREMENTS. 3. FIRE PROTECTION CONTRACTOR SHALL COORDINATE WITH THE WORK OF OTHER TRADES (ARCHITECTURAL CEILING PLAN, ELECTRICAL, AND HVAC ETCJ IN ORDER TO AVOID CONFLICTS WITH TH05E TRADES. 4. THE FIRE PROTECTION SPECIFICATIONS SHALL BE -READ IN CONJUNCTION WITH THESE DRAWINGS FOR ADDITIONAL INFORMATION. 5. THE FIRE PROTECTION CONTRACTOR SHALL COORDINATE THE SPRINKLER WORK WITH THE OWNERS GENERAL CONTRACTOR'S OR CONSTRUCTION MANAGER'S PHASING SCHEDULE PRIOR TO COMMENCEMENT OF ANY WORK. 6. GENERAL NOTES ARE APPLICABLE TO ALL FIRE PROTECTION DRAWINGS 1. FtRE PROTECTION CONTRACTOR SHALL BE -RESPONSIBLE FOR PROVIDING CAST IRON SLEEVE TO ALLOW FIRE STOPPING AROUND SPRINKLER PIPING THAT PENETRATES FIRE RATED WALLS, FLOORS AND CEILINGS. 8. FIRE PROTECTION CONTRACTOR SHALL BE-RE5PON5113LE FOR PROVIDING A N16HTWATCH WHILE THE SPRINKLER SYSTEM 15 INACTIVE AND ARRANGE HIS WORK TO ALLOW THE SYSTEM TO BE BROUGHT BACK ONLINE AT THE END OF EACH WORKING DAY. Q. PROVIDE 5E15MIC-RESTRAINT5 PER CURRENT STATE CODE-REQURREMENT5 AND NFPA 13 STANDARDS. 10. FtRE PROTECTION CONTRACTOR SHALL PROVIDE SIX SPARE SPRINKLERS OF EACH TYPE AS WELL AS ASSOCIATED SPARE SPRINKLER CABINET AND WRENCH. 11. SPRINKLER CONTRACTOR SHALL PROVIDE PROFESSIONAL ENGINEERING 5ERVICE5 AND HYDRAULICALLY CALCULATED SPRINKLER SYSTEM SHOP DRAWINGS AND SHALL SUBMIT SPRINKLER DE516N TO LANDLORDS INSURER FOR APPROVAL. THE 5YSTEM SHALL INCLUDE A SAFETY FLOW AND PRE95URE MARGIN OF 10 PERCENT. 5PRI14KLER OCCUPANCY HAZARD CLA551FICATION: - RETAIL AND STORAGE ROOMS: ORDINARY HAZARD GROUP 2 AT MAXIMUM OF 130 50. FT. PER SPRINKLER, 0.15 GPM PER 2500 50. FT. 12. ANY SPRINKLER SERVICE INTERRUPTIONS TO ADJACENT FLOORS AND SPACES MUST BE COORDINATED IN ADVANCE WITH THE GENERAL CONTRACTOR AND KEPT TO A MINIMUM. THIS SHALL AL50 INCLUDE SERVICE INTERRUPTIONS AND CONNECTIONS TO MECHANICAL AND ELECTRICAL SYSTEMS AFFECTING OTHER TRADES. REMOVAL OF EQUIPMENT, ETC. SELECTED WORK MAY BE REQUIRED TO 13E DONE DURING "OFF PEAK" HOURS AT THE GENERAL CONTRACTORS DISCRETION. 12. FIRE PROTECTION CONTRACTOR ALSO SHALL BE RESPONSIBLE FOR, BUT NOT LIMITED TO THE FOLLOWING: A. OBTAINING ALL REQUIRED PERMITS B. INSTALL, TEST AND CLEAN ENTIRE TENANT SPACE SPRINKLER SYSTEM PER THE NFPA 13 STANDARDS C. PROVIDE ALL EQUIPMENT, SPRINKLERS, PIPE, FITTIN65 d VALVES. D. PIPE SUPPORTS, ANCHORAGE AND SADDLES. E. DRILLING FOR ALL SPRINKLER PIPING FLOOR d WALL PENETRATIONS F. PROVIDING A5-BUILT SHOP DRAWINGS AND HYDRAULIC CALCULATIONS STAMPED AND SIGNED BY A REGI5TERED PROFE55IONAL ENGINEER IN THE REGULATING STATE. 14. THE SPRINKLER CONTRACTOR SHALL REMOVE FROM THE SITE AND PROPERLY DISP05ED OF ALL REMOVED PIPE, FITTINGS, HANGERS, SPRINKLERS, ETC. PER THE DIRECTION OF THE GENERAL CONTRACTOR 15. ALL SPRINKLERS LOCATED IN ORDINARY HAZARD AREAS SHALL BE: ORDINARY TEMP. 16. SPRINKLER CONTRACTOR SHALL LOCATE SPRINKLERS IN CENTER OF TILE PATTERN WHILE MAINTAINING PROPER COVERAGE AND COORDINATE LOCATIONS WITH FINAL WALL LOCATIONS, CEILING GRID, SOFFITS, CEILING DEVICES, LIGHTS, HVAC DIFFUSERS, GRILLES, ETC.. 11. FIRE PROTECTION (SPRINKLER) SHALL BE BY THE MALLS VENDOR - CROWN SPRINKLER. 18. FtRE ALARM SHALL BE BY MALLS VENDOR - G)ARDIAN SECURITY. SPRINKLERS: A. SPRINKLERS SHALL BE MANUFACTURED BY STAR, -RELIABLE OR VIKING AND SHALL BE 5TANDARD-RE5P0N5E WITH ORDINARY TEMPERATURE RATING. B. SPRINKLERS IN FINISHED GYP. BOARD CEILING (SALES FLOOR) SHALL BE 4RELIABLE' 674 CONCEALED TYPE WITH WHITE COVERPLATES. C. 5PRINKLER5 IN FINISH CEILING (STOCK ROOM) SHALL BE 'RELIABLE' MODEL 'CY PENDENT TYPE WITH CHROME ESCUTCHEONS. D. SPRINKLERS IN NON -CEILING AREAS SHALL BE 'RELIABLE' MODEL UPRIGHT TYPE WITH BRA55 FINISH. 1' DROP NIPPLE I "x 1/2" REDUCER CONCEALED SPRINKLER HEAD uts) Q O I" ELBOW c;j d 550 ow SPRINKLER MAIN OR :BRANCH LINE 1w CEILING CONSTRUCTION RETURN BEND PETAI L SCALE: NONE RECEIVED CITY OF TUKWILA FEB 2 6 2015 PERMIT CENTER FIRE PROTECTION LEGEND • CONCEALED SPRINKLER O UPRIGHT SPRINKLER O PENDENT SPRINKLER EXISTING SPRINKLER TO REMAIN .J Q W 0 (Y W W z_ 0 z W L.L ASSOCIATES II, L.L.C. 281 Farmington Avenue I Farmington, CT. 06032 SHEET NO. PLUMBI N6 FIXTURE 50HEDULE PLUMBING FIXTURE NOTES: I, THE PLUMBING SUBMITTALS SHALL HAVE ALL EQUIPMENT/FIXTURE5 AND ASSOCIATED TRIM IDENTIFIED AS INDICATED BELOW FOR APPROVAL. 2. THE PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY TRIM (ADAPTERS, SUPPLIES, 5TOP5, TRAPS, FITTINGS, ETCJ TO MAKE FINAL CONNECTION AND INSTALL A COMPLETE SYSTEM. 3. ALL HANDICAP FIXTURES SHALL BE INSTALLED PER LOCAL REQ'5. INSULATE ALL EXPOSED PIPING 4 VALVES BELOW FIXTURE WITH "TRUE-BRO KIT". 4. REFER TO THE ARCHITECTURAL DETAIL DRAWINGS FOR INFORMATION REGARDING FIXTURE MOUNTING REQUIREMENTS AND EXACT FIXTURE LOCATIONS. 5. ALL EQUIPMENT MUST BE GSA APPROVED. TYPE FIXTURE 50IL/ WASTE VENT HOT WATER GOLD WATER MOUNT DESCRIPTION STERN WILLIAMS GORLOW #SBG-1100 with ❑A Mop Sink 3" I-I/2" 3/4' 3/4' Floor "STERN-WILLIAM5' # T-10-VB wall mounted '5TERN44ILLIAM5 Faucet. Also provide # T-40 mop hanger. ABOVE "HTP" MODEL # EVCOIO EWH Water Heater --- --- 3/4' 3/4- TOILET 10 Gallons, 120V, 150OW ROOM Expansion ion ABOVE "AMTROL" Model #AST-5 HWET ank ___ ___ ___ I/2° TOILET with all fittings for a complete Installation ROOM 3/4' GW -' 1/2" GW HWET'* EXP. TANK SEE SCHEDULE n 3/400 TIP RELIEF VALVE 2" WIDE 15 GA. SHEET METAL BAND. SECURE TO WALL FOR SEISMIC BRACING WHERE REQUIRED BY CODE. I" DRAINS TO FLOOR DRAIN VACUUM BREAKER* Ib BALL VALVE (TYPJ UNION (TYPJ E_WH: 10 GALLON WATER HEATER HEAT TRAP, TYPICAL. MINIMUM I&" DEEP. 18 GA. GALV. DRIP PAN * AS REQUIRED BY LOCAL CODES. INSTALL PER MANUFACTURER'S INSTRUCTIONS. ** AS REQUIRED BY LOCAL CODES AND WATER HEATER MFR'5 RECOMMENDATION. NOTE: THE ABOVE DETAIL 15 TO SHOW GENERAL REQUIREMENTS OF INSTALLATION. PIPING CONFIGURATION MIGHT NOT MATCH ACTUAL LAYOUT. TYPICAL WATER HEATER DETAIL SCALE: NOT TO 50ALE CONNECT NEW I Y2"v TC MALLS EXISTING VENT MAIN. NEW 10 GALLON ELECTRIC WATER HEATER AND AUXILIARY DRAIN PAN MOUNTED ON PLYWOOD BASE ABOVE TOILET ROOM. EXISTING SINK SHALL REMAIN, REINSTALL AFTER NEW FINI5HE5 ARE INSTALLED. -RECONNECT NEW HW AND GW PIPING TO EXISTING SINK. PLUMBING PLAN SCALE: 1/4" =1'-0" PLUMBING 6ENERA►L NOTES: 61 NEW COLD WER IN5TAj4LEV FOR NEW WAArER FILITRATION 15YSTEMNE Y G.G. CONNECT NEW 3" SANITARY ❑A I LINE TO EXISTING BRANCH 3° 5ANMAIN, e NEW 3/4"4P BRANCH WATER MAIN FROM EXISTING MALLS SYSTEM. COORDINATE CONNECTION POINT AND ROUTING WITH MALLS REPRESENTATIVE. toCW iI J = EXISTING 5ANITA IF 1.Y L INES e it ii I I EXISTING FLOOR — M EXISTING FLOOR EXISTING TOILET SHALL REMAIN. REINSTALL DRAIN, i I, r GLEAN OUT, AFTER NEW FINISHES J ARE INSTALLED. NEW I" AUXILIARY DRAIN LINE RUN DOWN IN WALL AND STUBBED OUT AT FLOOR LEVEL. I. THIS JOB INCLUDES ADDITIONS/RENOVATION5 OF AN EXISTING FACILITY. BEFORE SUBMITTING BID. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME THOROUGHLY FAMILIAR WITH ALL EXISTING CONDITIONS. THIS CONTRACT INCLUDES MODIFICATIONS OF EXISTING SYSTEMS REQUIRED FOR THE INSTALLATION OF NEW EQUIPMENT. ALL NEW AND EXISTING EQUIPMENT AND SYSTEMS SHALL BE FULLY OPERATIONAL BEFORE THI5 CONTRACT 15 CONSIDERED COMPLETE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY ASSUMPTIONS, OMISSIONS OR ERRORS MADE AS A RESULT OF FAILURE TO BECOME FULLY FAMILIAR WITH THE EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS OF ALL TRADES. 2. DRAWINGS ARE DIAGRAMMATIC AND SHOW GENERAL INTENT OF WORK; NOT EXACT EQUIPMENT LOCATION. PLUMBING CONTRACTOR MUST COORDINATE EQUIPMENT AND PIPING LOCATIONS WITH OTHER TRADES AND ARCHITECTURAL WORK BEFORE WORK BEGINS, 3. PLUMBING CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES (HVAC, ELECT., STRUCTURAL, ETC:) IN ORDER TO AVOID CONFLICTS WITH TH05E TRADES. 4. REFER TO THE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. THE PROJECT SPECIFICATIONS SHALL BE READ IN CONJUNCTION WITH THESE DRAWINGS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. 5. LOCATION OF ALL EXISTING PIPING SHOWN ON FLOOR PLANS 15 BASED ON THE BEST AVAILABLE INFORMATION. THE PLUMBING CONTRACTOR SHALL VERIFY ALL SIZES. DEPTH, LOCATION AND PIPE MATERIALS OF EXISTING PIPING IN THE FIELD. 6. THE CONTRACTOR SHALL COORDINATE AND SCHEDULE (PREMIUM OFF -HOURS IF NECESSARY) WITH THE OWNER THE SHUT -DOWN OF THE EXISTING PLUMBING 5Y5TEM5 FOR FINAL CONNECTION OF NEW PIPING OR GAPPING OF EXISTING PIPING PRIOR TO COMMENCEMENT OF WORK 50 THAT ANY DISRUPTIONS TO ACTIVE MAINS ARE KEPT TO MINIMUM, 1. THE INTERRUPTIONS IN DAILY OPERATIONS MUST AL50 BE COORDINATED IN ADVANCE WITH OWNERS DESIGNATED REPRESENTATIVE. THIS SHALL INCLUDE SERVICE INTERRUPTIONS AND CONNECTIONS, MECHANICAL AND ELECTRICAL EQUIPMENT AFFECTING OTHER TRADES. 6. THE PLUMBING CONTRACTOR SHALL COORDINATE THE PLUMBING WORK WITH THE OWNER'S GENERAL CONTRACTOR'S OR CONSTRUCTION MANAGER'S PHA5IN6 SCHEDULE PRIOR TO COMMENCEMENT OF ANY WORK. q. ALL PIPE PENETRATIONS IN FIRE WALLS AND ALL FLOORS PENETRATIONS SHALL BE SEALED AROUND PIPE WITH SPRAY -IN TYPE INTUME56ENT FOAM OR AN APPROVED SILICONE FIRE STOP CAULKING. 10. LOCATE FLOOR DRAINS AT LOWEST POINT OF PITCHED FLOOR. II. EXTEND EXISTING 1/2" BURIED TRAP PRIMER LINE (WITH 1/2"ARMAFLEX) FROM LAVATORY TRAP TO FLOOR DRAIN IN TOILET ROOM, 12. UNLESS OTHERW15E NOTED, ALL ITEMS GALLED FOR TO BE REMOVED, DEMOLISHED OR RELOCATED SHALL BE BY THE PLUMBING CONTRACTOR. 13. ALL GOLD, HOT AND CONDENSATE PIPING SHALL BE INSULATED. 14. CONTRACTOR MUST X-RAY SLAB PRIOR TO ANY TRENCHING OR GORING. 15. PLUMBER SHALL BE PROPERLY LICENSED. 16. ALL ABANDONED ABOVE AND BELOW GROUND PIPING SHALL BE REMOVED IN IT'5 ENTIRETY AND GAPPED AT THE MAIN, 1-7. ALL FLOOR DRAINS TO BE VENTED SEPARATELY. 15. PROVIDE SEPARATE AIR CHAMBERS AT FIXTURE SUPPLY. (THE LENGTH SHALL BE 24X THE IN51DE DIAMETER OF THE BRANCH MAIN) RECEIVED CITY OF TUKWILA FEB 2 6 2015 PERMIT CENTER PI PI N6 L 1 NETYPE LEGEND - - GOLD WATER (CH) - - - - HOT WATER (HW) UNDER SLAB WASTE --------------------- -------- VENT PLllMBIN6 SYMBOLS KEY I SYMBOL I DESCRIPTION I G PIPE DROP 0— PIPE RISE UP TEE DOWN 0-- FLOOR GLEANOUT 6BALL VALVE I 0 -7 p - z O mLU p O z z w w 0 LU Q O Z 3 jLij m0 LU LU w LI) d a mo ryNN z a a T Nt pk J d W (Y W W z z W L.I. ■ I..L LL ASSOCIATES II, L.L.C. 281 Farmington Avenue I Farmington, CT. 06032 SHEET NO. P101 r.lio PLUMBING AND FIRE PROTECTION SPECIFICATIONS GENERAL A. Desginer's General Conditions are a part of this Division. All work shall be done in strict accordance with all applicable Codes and Regulations of local and State Agencies, Owner's Insurance underwriter, local Fire Marshal and utility companies. Contractor shall bear the cost of all fees, permits, licenses and taxes and any utility company charges in connection with the work. All equipment installed shall be UL listed. B. Contractor shall allow that work may need to be accomplished under premium time and must be coordinated with the Owner. SCOPE A. Demolition: I. Disconnect and remove all plumbing Fixtures, piping, hangers and accessories which will no longer be used. Cap piping concealed. -Remove back to mains unless otherwise noted. Do not leave dead ends. 2. Existing fixtures shall NOT be reused unless so indicated on the Drawings. 3. Disconnect and remove all sprinklers, piping, hangers and accessories as required for renovation. 4. Existing sprinklers, piping, etc. shall NOT be reused unless so indicated on the Drawings. 5. All materials removed under these divisions not scheduled for reuse or requested by the Owner, shall be properly disposed of off site meeting all applicable regulations of local State Agencies. B. New Work: 1. Furnish and Install modifications to existing plumbing system For the tenant space including, but not limited to: hot and cold water, sanitary, waste and vent piping; Fixtures; insulation and all other equipment as indicated on the plans, as herein specified and as necessary to provide complete and operational systems. Systems shall be complete in all respects, tested, approved and ready to operate. The Plumbing Contractor shall arrange his work so that any shutdown does not interfere with the Owner's operation of the existing facility- 6. Furnish and install complete tenant space sprinkler piping system modifications Including main and branch piping, sprinklers, hangers and seismic protection. I. Modify existing sprinkler piping to accommodate the new ceiling construction and sprinkler layout, install swing joints in pipe drops For center of tile locations. Provide new sprinklers. 2. Sprinklers shall be 165 degrees. D. Work by Others: 1. The General Contractor shall provide chases, openings, cutting, patching, painting and finish work. 2. The General Contractor shall install ail access doors where required; doors needed for access to mechanical and electrical systems shall be Furnished by the specific trade Contractor. SHOP DRAWING SUBMITTALS A. Submit shop drawings on equipment and materials (6 copies), to the Desginer For approval. The Drawings shall include ratings performance information, operating data and wiring diagrams. The Contractor shall assume Full responsibility for work performed or equipment supplied that is not in agreement with approved shop drawings. B. The following list of mechanical items must be submitted by contractor for approval: 1. Sprinkler system drawings including hydraulic calculations. 2. Sprinkler system components. 3. Plumbing fixtures and equipment. 4. Plumbing drain assemblies. 5. Piping materials. 6. Valves. 1. Insulation materials. & Hangers and supports, including seismic bracing equipment. Cl. Sleeves. G. Submit for record on itemized list detailing mechanical systems and components to be seismically restrained and associated seismic restraint system to be used. RECORD DRAWINGS A. Neatly and accurately record all changes to Contract Documents on record set of drawings furnished by the General Contractor. These record "as -built" drawings shall Include locations of specific items as listed in the various specification DIVISIONS. Upon project completion, these record drawings shall be turned over to the Engineer. DEFINITIONS A. As used on Contract Drawings, the term "to provide" shall mean "to Furnish", Install and connect completely in the specified or approved manner the item or material described." GUARANTEE A. Materials, equipment and workmanship shall have standard warranty against defects in material and workmanship. Failures due to defective or improper material, equipment, workmanship or design shall be made good, forthwith, by and at the expense of the Contractor, including damage done to areas, materials and other systems resulting from such failures. Guarantee period shall extend for one year from the Date of Acceptance. Retain below IF procedures For welder certification are retained in 'Quality Assurance" Article. INSPECTION A. Contract Drawings are diagrammatic and do NOT show every required Fitting, etc. The Contractors shall examine the architectural and MEP Drawing and Specifications to determine the scope of work and Familiarize themselves with existing site conditions prior to submitting a bid, and shall include ail equipment and accessories necessary for complete and operational systems. B. IF so directed by the Desginer or Engineer, the Contractor shall, without extra charge, make reasonable modifications in the layout to prevent conflict with those of other trades and for proper installation of work. Refer to the Desginer's Reflected Ceiling Plan For exact location of air diffusers, registers and grilles. The Contractor shall coordinate locations of equipment with all trades before starting construction. Any modification to the equipment layout required For installation shall be performed at no additional cost to the Owner. ARRANGEMENT OF WORK A. Work shall be coordinated between trades to prevent interference. Work shall present a neat coordinated appearance. Install work as necessary to provide maximum possible headroom, adequate clearance and ready access For inspection, operation, safe maintenance and repair and Code conformance. Where space appears inadequate, consult the Desginer before proceeding with installation. WORKMANSHIP A. Equipment and materials shall be new, of first quality, selected and arranged to fit properly Into spaces Indicated. Install equipment and materials in accordance with manufacturer's recommendations. COORDINATION WITH OWNER A. Work shall be scheduled with the Owner. Interruptions in Owner's access to the site shall be subject to Owner limitations of date and duration. OPERATION OF SERVICES AND UTILITIES A. Shutdown of existing services and utilities shall, without exception, be coordinated with the proper utility and with the Owner as to date, time of day, and duration before any service Is interrupted. Notify the Owner of estimated duration of shutdown period at least ten days in advance of proposed shutdown. In renovation work, FIRE PROTECTION 5Y5TEM5 FOR RENOVATIONS MUST BE REACTIVATED AT THE END OF EACH WORK DAY. PROTECTION A. Close open ends of work with temporary covers or plugs during construction to prevent entry of Foreign material. Protect existing property, equipment and Finishes From damage. Repair, to original condition, existing property that has been damaged during execution of the work. GLEANING A. Work site must be kept clean. Rubbish, debris and leftover or excess materials shall be removed daily. PAINTING A. Equipment and materials shall have standard manufacturer's Finish except where otherwise noted. GUTTING AND PATCHING A. Gutting and patching to be performed by General Controctor/this Contractor. Painting of finished surfaces after patching shall be as specified by Desginer or shall match adjacent finishes. WATERPROOFING A. Provide necessary sleeves, caulking and Flashing required to make openings waterproof. FIREPROOFING A. At closing of each working day, provide temporary Firestopping in every opening cut between floors and through Fire -rated partitions. Permanent firestops shall be provided around sleeves and at other permanent openings through Fire -rated partitions and floors, as required. Materials used For Fire stopping sholl be Glass A "Incombustible" with firestopping capabilities equal to that of adjacent construction. SUPPORTS A. Provide necessary supports. Equipment shall be securely attached to building structure in acceptable manner in compliance with State Seismic Code. SEISMIC REQUIREMENTS A. Submit six (6) copies of a Final inspection report which includes. Sealed certification by a Structural Engineer with P.E. registration in the State of Construction permit, that: I. Engineer has reviewed the project. 2. Engineer has approved the use of the devices For the particular applications. 3. The devices satisfy Specification- and Code -mandated seismic criteria. B. Refer to individual Divisions For specific requirements. I O ACCESS ry z — `r A. Provide adequately sized access doors, For access to concealed equipment and ry m components requiring servicing or inspection. Doors sholl have Fire ratings equal to p Z construction in which they are located. Z 3 TE5T5 Q Q > A. Performing tests required by the Owner, legal authorities and agencies. Each piece Q QC v W L1 Ll ail Q ['L of equipment, including motors and controls, shall be operated continuously For minimum one -hour test. Correct all defects appearing during tests, and repeat Z Z tests until no defects are disclosed. Final tests shall be made in the Owner's presence.CL w 5Y5TEM5 OPERATION AND MAINTENANCE Z Q j m O A. Upon completion of the work and at a time designated by the Engineer, the c1 W Contractor shall furnish (5) instruction manuals including data, warranties, etc., and v i 43 shall instruct the Owner or his representative as to the arrangement, location and furnished installed the > operation of all equipment and systems and under W in Mechanical and Electrical Contract. Q m n! ry (LU 0 N FIELD MEASUREMENTS "`- N A. The Contractor shall verify in the Field all measurements necessary For the work, 1723 PERMITS, LAWS, ORDINANCES, CODES and STANDARDS A. Obtain and pay for permits, inspections, licenses and certificates required. Work of this Contract shall meet State Building Code, adopted State Plumbing Code, State Fire Safety Code and other laws, rules and regulations of local, State and Federal authorities; National Fire Protection Association #13, 2002 Edition. 10-01 INSURANCE A. Furnish insurance certificates required by the Owner. FIRE PROTECTION PRODUCTS PIPING ^ v Tn v1 A. Above -grade piping 2-1/2" and larger shall be black steel Schedule #10 meeting A5TM Al95, with ductile iron Fittings meeting A5TM A536 rated for grooved pipe 115 psi working pressure. Piping 2' and smaller shall be Schedule 40 black steel meeting A5TM A1g5, with 125 lbs. Cast iron threaded fittings. All shall pipe piping be adequately supported by using adjustable swivel ring and round iron rod type hangers. Maximum distance between hangers shall be 12'-O" on center. SEISMIC RE5TRAINT5 h+ l A. Provide seismic bracing on all new and existing sprinkler piping renovation areas per NFPA # 13 standards. B. Provide seismic bracing and restraint at turns or more than 4 Feet and throughout entire run where piping is supported by hangers longer than 12" as measured From ♦ bottom of supporting structure to top of pipe, as required by NFPA. 13. C. Restraints shall be as follows: I. Piping 2-1/2" and larger; Mason Industries Type 5R-C. PLUMBING PRODUCTS n . PIPING, VALVES, INSULATION, ETC. - PLUMBING • A. Sanitary, waste and vent piping below grade shall be service -weight cast iron bell and spigot, with push -on neoprene-gosketed joints, meeting 015Pi Standard M #301-CIO. p B. Sanitary, waste and vent piping above grade and ail branch waste and vent piping above grade shall be no -hub cast iron with no -hub couplings meeting A5TM Standard #0564. "L" C. Domestic water pipe above grade shall be Type copper with wrought copper I sweat fittings using lead -Free C15/5 solder. Valves shall be two piece boll type with r'1 screwed ends, provide union on one end: Watts #B60&0 or equivalent. •j D. Domestic hot water piping shall be insulated with I" thick, and domestic cold water piping with 1/2" thick Owens Corning Fiberglass insulation with preformed insulated Fittings and vapor barrier. Insulation shall be installed per manuFacturer's recommended instructions. SEISMIC, RESTRAINTS A. Provide seismic bracing on all new and existing plumbing piping as required in renovation areas per state code requirements. O B. Provide seismic bracing and restraint at turns of more than 4 feet and throughout E.y entire run where piping is supported by hangers longer than 12" as measured From bottom of supporting structure to top of pipe. pd 1 R G. Restraints shall be as follows: ' LI I. Piping 2-1/2" and larger; Mason Industries Type 5R-C rA l GO O 16 tip15 Ma dly- G vO neN O RECEIVED CITY OF TUKWILA FEB 2 6 -2015 P 1FAW9 ERMIT AND PPROVAL EQUIRED Plott on Recwded F J W N U Z W 281 Farmington Avenue Farmington, CT. 06032 SHEET NO. INSTALL NEW THERMOSTAT WITH LOCKING CLEAR PLASTIC COVER IN THE LOCATION INDICATED ON THE PLAN. THERMOSTAT SHALL BE PROGRAMMABLE TYPE COMPATIBLE WITH VAV'5. MOUNT AT 4&" A.F.F.. (TYPICAL OF 2) !7 I. THE CONTRACTOR FOR THI5 DIVISION OF WORK 15 REQUIRED TO -READ THE SPECIFICATIONS AND -REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND 15 RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL HIS/HER SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 2. THE CONTRACTOR SHALL PROVIDE ALL MATERIALS, EQUIPMENT, AND LABOR REQUIRED TO INSTALL A COMPLETE SYSTEM AS INDICATED ON THE DRAWINGS, AS SPECIFIED, AND AS REQUIRED BY STATE AND LOCAL BUILDING CODES. 3. THE CONTRACTOR SHALL INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, THE CONTRACT DOCUMENTS, AND APPLICABLE CODES AND REGULATIONS. 4. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL, STRUCTURAL, PLUMBING, ELECTRICAL WORK, ETC. SHOWN OR SPECIFIED ON OTHER CONTRACT DOCUMENTS. 5. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS THAT ARE NOT DIMEN51ONED ARE APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS SHALL BE BASED UPON PROJECT MALLS EXISTING EXHAUST - MAIN. AIR DISTRIBUTION MAIN. V - - 1 11\ 1 1\1 1 ,11 1 1" 1N 1 111 , 111 1 „1 , 1\1 S1� 1 6%V SHALL REMAIN. 171 010 1 00, 1 REMOVE DUCT MAIN, BRANGHE5 AND DIFFUSERS BACK TO "'+00, 01 1, ,1 -- EXISTING-VAV-BOX -- - ----- - - - - ; - - - - -------------- -- -- +- iV z z z' - -.n , 111 1 "1 MECHANICAL M L I T I ®N LAN SCALE: 3/16"=1'-0" MALL'5 EXISTING EXHAUST MAIN. 5GALE: I/4"= I'-0- SITE CONDITIONS. DO NOT SCALE DRAWIN675. b. THE CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT, PIPING, AND DUCTWORK NOT BEING USED OR SHOWN TO REMAIN 15 TO BE FULLY REMOVED AND NOT ABANDONED IN PLACE. 1. ALL EQUIPMENT, INSTALLATIONS, AND MATERIALS SHALL COMPLY WITH ALL APPLICABLE LANDLORD CRITERIA. 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL CONDITIONS PRIOR TO FINAL BID INCLUDING ALL EXISTING 5TUB-IN5 AND TAPS FOR MECHANICAL SYSTEMS WITHIN THE TENANTS SPACE. q. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL CONNECTIONS TO THE LANDLORD'S BASE BUILDING SYSTEM AS APPLICABLE. COORDINATE ALL SYSTEMS IN FIELD WITH LANDLORD. 10. NO FIBERGLASS DUGTBOARD ALLOWED. II. COORDINATE DIFFUSER AND GRILLE LOCATIONS WITH ARCHITECTURAL CEILING PLAN, LIGHTING, AND FIRE PROTECTION PLANS. 0 12. CONTRACTOR SHALL COORDINATE LEAD TIMES WITH LOCAL EQUIPMENT -REPRESENTATIVE AND ADVISE OWNER OF ANY DELAYS ON EQUIPMENT. IF LEAD TIMES ARE GOING TO IMPEDE ON THE SCHEDULE , THE CONTRACTOR SHALL SUBMIT AN ENGINEER APPROVED ALTERNATE MANUFACTURER TO MAINTAIN OWNERS SCHEDULE. 13. CONTRACTOR MUST SUBMIT CERTIFIED SUBMITTALS FOR A HVAG EQUIPMENT WHICH MUST BE APPROVED PRIOR TO PURCHASE. 14. CONTRACTOR SHALL READ THRU MALL'5 CRITERIA PRIOR TO BID. 15. CONTRACTOR SHALL GLEAN AND SERVICE ANY REMAINING EXISTING EQUIPMENT TO A554JRE PROPER WORKING ORDER. Ib. CONTRACTOR SHALL CONFIRM THE -REQUIREMENT OF SMOKE DETECTORS WITH LOCAL JURISDICTION AND COORDINATE WITH FIRE ALARM VENDOR. - -- - - - -- - - --- -j t-- MC,T BLOCKS SENSORS 4 PAMPERS DIFFUSER -SUPPLY GRILLE -RETURN A TYPE46FM NECK 51ZE 0IFFU5ER/GRILLE GALLOUT HFP DUCTWORK TO BE DEMOLISHED - - - - INSULATED DUCT NEW THERMOSTAT (VO) VOLUME DAMPER (MD) MOTORIZED DAMPER DUCT SMOKE DETECTOR FIRE DAMPER t�b1 i iry n, $ p yf5is ' ABBREV I AT IONS CONNECT TO EXISTING EF EXHAUST FAN EDH ELECTRIC DUCT HEATER RTU ROOF TOP UNIT FGU FAN COIL UNIT CHWS CHILLED WATER SUPPLY GHWR CHILLED WATER -RETURN RECEIVED CITY OF TUKWILA FEB 2 6 2015 IT CENTER SEPARATE PERMIT AND APPROVAL ry-1 1 Q 0 m z W C� W 0 N � p W w ry O W t 1- z 0- WNa v w 5; 9- w w ,n LUQ � mrym ryryN J Q W N W W z 0 z W 281 Farmington Avenue I Farmington, CT. 06032 SHEET NO. VARIABLE AIR VOLUME BOX 50HEDULE UNIT ROOM MAX MIN STATIC PRESSURE NG LEVEL HEAT # E L ELEC. DATA INLET DOWN MIN RAP. D15. VOLTS PH No. SERVING GFM GFM GFM KW 5TEP5 oA.T, F oA.T, F REMARKS EX-VAV-I SALES FLOOR 21�0 651 - - - - - 651 10.0 1 - - 208 1 I, 2, 3, 4, 5 VAV-2 STOCK ROOM 500 150 1 0.5 1 0.25 1 0.06 �O 15 150 LO 1 50.0 10.0 2O8 I NOTES 1. CONTRACTOR PROVIDED VAV BOXES FROM MANUFACTURER 3. PROVIDE In DUAL DENSITY LINING. 5PEGIFIED IN THE TENANT CRITERIA. 4. PROVIDE 24V TRANSFORMER. 2. PROVIDE COMPATIBLE CONTROLS TO INTERFACE WITH 5. RE-U5E EXISTING VAV BOX. MALL'S DDG SYSTEM. 6. VAV'S ARE NON FAN POWERED. D I FFIU5ER AND REC 15TER 50HEDJJLE UNIT MANUFACTURER DUTY SIZE MATERIAL REMARKS TYPE 4 MODEL 4 TYPE A TITUS OMNI SUPPLY 24x24 SURFACE STEEL NOTE I B TITUS OMNI SUPPLY 12A2 SURFACE STEEL NOTE I G TITUS 50F -RETURN 12A2 SURFACE STEEL NOTE I D TITUS 50F -RETURN 24x24 SURFACE STEEL NOTE NOTE5 : I. TO BE FIELD PAINTED TO MATCH ADJACENT CEILING FINISH. REFER TO FINISH PLAN FOR COLOR. WHERE DIFFUSER IS USED IN 5TOCKROOM, PROVIDE PROPER HARDWARE FOR MOUNTING AND AND LEAVE WHITE. TYPE A-500-GFM cl x cl -NECK SIZE OR GRILLE SIZE APPVD. EXI STEEL STRi DUCTWORK SELF -TAPPING, SHEET METAL SCREW 25-1/4", 21-1/4"• Iq-1/4" OR 13-1/4" OUTSIDE DIMENSION I-7" OR II" INSIDE DIMENS1ON 24% 20% IS" OR 12- "G" CHANNEL REINFORCING BY (5.G. AROUND OPENING MOUNTING 5GREW FIELD INSTALLED DRYWALL CEILING ry �-77 r I-I/8" STEEL MOUNTING FRAME DRYWALL MOUNTING FRAME DETAIL SCALE: NOT TO SCALE NOTE: I. MOUNTING FRAME PROVIDED BY MANUFACTURER. R n TRI Ale; HANGER SPACING DUCT FACE AREA FROM O TO 4 50. FT. HANGERS q&" O.G. MAX. DUCT FACE AREA FROM 4 TO 10 50. FT. HANGER5 12" D.G. MAX. DUCT FACE AREA FROM 10 50. FT. AND GREATER HANGERS 45" O.G. MAX. WHERE DUCTS ARE LESS THAN 2 50. FT. IN FACE AREA, HANGERS SHALL BE NOT LE55 THAN 1" x 1/16" STRAP STEEL. WHERE DUCTS ARE GREATER THAN 2 50. FT. IN FACE AREA, HANGER5 SHALL BE NOT LE55 THAN I" x 1/5" STRAP STEEL. WHERE DUGT5 ARE & 50. FT. IN FACE AREA. HANGER5 SHALL BE BRACED BY I" x I" x 115" STEEL ANGLES ALL AROUND, SPACED NO MORE THAN 45" O.G. WHERE DUCTS ARE OVER 4&" WIDE, THE HANGER5 SHALL BE BROUGHT DOWN UNDER THE DUCT 51DES 4" AND FASTENED TO THE BOTTOM. DUCT HANGER DETAIL 5GALE--NOT TO SCALE MECHANICAL LOAD GALGULATIONS Sales Floor COOLING COIL PEAK Peaked at Time: Mo/Hr 7 / 14 Oulside Air. OADB/WB/HR: 79164167 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total Btu/h Btu/h Bluth (%) Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0 Roof Cond 0 0 0 0 Glass Solar 0 0 0 0 Glass Cond 0 0 0 0 Wall Cond 0 0 0 0 Partition 0 0 0 Floor 0 0 0 Adjacent Floor 0 0 0 0 Infiltration 0 0 0 Sub Total =_> 0 0 0 0 Internal Loads Lights 8,519 0 8,519 17 People 31,500 0 31,500 63 Misc 10,239 0 10,239 20 Sub Total =_> 50,258 0 50,258 100 Ceiling Load 0 0 0 0 Vertilation Load 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0 Exhaust Heat 0 0 0 Sup. Fan Heat 0 0 Ret. Fan Heat 0 0 0 Duct Heat Pkup 0 0 0 Underlir Sup Ht Pkup 0 0 Supply Air Leakage 0 0 0 Grand Total => 50,258 0 50,258 100.00 Main Cig Aux Clg Opt Vent Total Stock Room CLG SPACE PEAK Mo/Hr 7114 OADB: 79 Space Percent Sensible Of Total Btu/h (%) Envelope Loads 0 0 Skylite Solar 0 0 Skylite Cond 0 0 Roof Cond 0 0 Glass Solar 0 0 Glass Cond 0 0 Wall Cond 0 0 Partition 0.00 0 Floor 0 0 Adjacent Floor 0 0 Infiltration 0 0 Sub Total => Internal Loads 8,519 23 Lights 17,500 48 People 10,239 28 Misc 36,258 100 Sub Total =_> 0 0 Ceiling Load 0 0 Ventilation Load 0 0 Adj Air Trans Heat Ov/Undr Sizing 0 0 Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 36,258 100.00 Grand Total COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter OBIWBIHR Leave OBIWB/HR ton MBh MBh crm °F °F gr/lb °F °F grlib 4.2 50.3 36.3 2,169 72.0 62.2 69.3 56.8 54.3 60.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 4.2 50.3 COOLING COIL PEAK Peaked at Time: Mo/Hr. 7114 Outside Air: OADBIWB/HR: 79 / 64 / 67 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total WWII BbA Btu/h (°k) Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0 Roof Cond 0 0 0 0 Glass Solar 0 0 0 0 Glass Cond 0 0 0 0 Wall Cond 0 0 0 0 Partition 0 0 0 Floor 0 0 0 Adjacent Floor 0 0 0 0 Infiltration 0 0 0 Sub Total =_> 0 0 0 0 Internal Loads Lights 819 0 819 9 People 1,350 0 1,350 15 Misc 6,826 0 6,826 76 Sub Total => 8,995 0 8,995 100 Ceiling Load 0 0 0 0 Ventilation Load 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 OvlUndr Sizing 0 0 0 Exhaust Heat 0 0 0 Sup. Fan Heat 0 0 Ret. Fan Heat 0 0 0 Duct Heat Pkup 0 0 0 Underfir Sup Ht Pkup 0 0 Supply Air Leakage 0 0 0 Grand Total 8,995 0 8,995 100.00 Main Clg Aux Clg Opt Vent Total RIGID INSULATION MAIN DUCT BRANCH - - - - - - - - - - - --- - - - - - - AIR FLOW / \ BRANCH FLOW--� I REFER TO SMACNA FOR VD CONNECTION/CONSTRUCTION I I INFORMATION ( I VOLUME I I DAMPER RIGID INSULATION I 1 � I 1 T*eFIGAL BRANCH DETAIL Floor Part ExFlr Roof Wan CLG SPACE PEAK Moil-Ir. 7 / 15 OADB: 80 Space Percent Sensible Of Total Btu/h M) Envelope Loads 0 0 Skylite Solar 0 0 Skylite Cond 0 0 Roof Cond 0 0 Glass Solar 0 0 Glass Cond 0 0 Wall Cond 0 0 Partition 0.00 0 Floor 0 0 Adjacent Floor 0 0 Infiltration 0 0 Sub Total =_> Internal Loads 819 10 Lights 750 9 People 6,826 81 Misc 8,395 100 Sub Total =_> 0 0 Ceiling Load 0 0 Ventilation Load 0 0 Adj Air Trans Heat Ov/Undr Sizing 0 0 Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Undernr Sup Ht Pkup Supply Air Leakage 8,395 100.00 Grand Total, COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DBMB/HR ton MBh MBh cfm "F 'F gr/Ib °F °F gr/ib 0.8 9.0 8.4 502 72.0 62.2 69.3 56.8 56.2 67.6 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 0.8 9.0 SCALE: NOT TO SCALE FROM SUPPLY AIR MAIN GEILING DIFFUSER Floor Part ExFlr Roof wan HEATING COIL PEAK Moll-Ir. Heating Design OADB: 26 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Blum Btu/h (%) 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0 0 0 0.00 0 0.00 0 0.00 -9,448 100.00 0 0.00 0 0.00 0 0.00 0 0.00 0 -9,448 100.00 AREAS Gross Total Glass ft2 (%) 1,452 0 0 0 0 0 0 0 0 TEMPERATURES Cooling Heating SADB 56.8 70.0 Ra Plenum 72.0 70.0 Return 72.0 70.0 RetIOA 72.0 70.0 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.0 0.0 AIRFLOWS Cooling Heating Diffuser 2,169 651 Terminal 2,169 651 Main Fan 2,169 651 Sac Fan 0 0 Nom Vent 0 0 AHU Vent 0 0 Infil 0 0 MinStop/Rh 651 651 Return 2,169 651 Exhaust 0 0 Rm Exh 0 0 Auxiliary 0 0 Leakage Own 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating % OA 0.0 0.0 cfmlft2 1.49 0.45 cfm/ton 517.85 ft2fton 346.69 Btu/heft2 34.61 -6.51 No. People 70 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm "F Main Htg -9.5 0 0.0 Aux Htg 0.0 0 0.0 Preheat 0.0 0 0.0 Humfdff 0.0 0 0.0 Opt Vent 0.0 0 0.0 Total -9.5 HEATING COIL PEAK Mo/Hr: Heating Design OADB: 26 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Bluth Btu/h (%) 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0 0 0 0.00 0 0.00 0 0.00 -2,187 100.00 0 0.00 0 0.00 0 0.00 0 0.00 0 -2,187 100.00 AREAS Gross Total Glass ft. (%) 957 0 0 0 0 0 0 0 0 TEMPERATURES Cooling Heating SADB 56.8 70.0 Ra Plenum 72.0 70.0 Return 72.0 70.0 ReUOA 72.0 70.0 Fn MOTO 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.0 0.0 AIRFLOWS Cooling Heating Diffuser 502 151 Terminal 502 151 Main Fan 502 151 Sec Fan 0 0 Nom Vent 0 0 AHU Vent 0 0 Infil 0 0 MinStop/Rh 151 151 Return 502 151 Exhaust 0 0 Rm Exh 0 0 Auxiliary 0 0 Leakage Own 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating % OA 0.0 0.0 cfm/ft2 0.52 0.16 cfm/ton 669.92 ft2Ron 1,276.68 Btu/heft' 9.40 -2.29 No. People 3 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm 'F Main Htg -2.2 0 0.0 Aux Htg 0.0 0 0.0 Preheat 0.0 0 0.0 Humidff 0.0 0 0.0 Opt Vent 0.0 0 0.0 Total -2.2 1 G D" G Ro �® PpP 6 ti0�� 1 Mai 1 1u��i�a N G� 1oNC, O,v15�0 eNix RIGID C UGTWORK WITH INSULATION AS SPECIFIED PRE-IN54JLATEP FLEXIBLE DUCTWORK (5' MAX. LENGTH) �- CONTRACTOR TO PROVIDE PROPER SUPPORT DI rFUS R MOUNT N6 SCALE: NOT TOMtqk M, I FIRE DAMPER (IF REQUIRED) RECE#VE© CITY OF TUKWILA FEB 2 6 2015 PERMIT CENTER SEPARATE E TA I kRMIT AND PROVAL REQUIRED PI d on Rec pled Pope m -7 w -1I p ry Z o N Ci Z Q ZwW� < W O � N CL O O to Z� 0. U.1 OLL 111 NW 'f' W 43 W Q mryN Ga z J Q w W W Z Z W U. ASSOCIATES II, L.L.C. 281 Farmington Avenue Farmington, CT. 06032 SHEET., -NO. M2*1 DIVISION 15 - MEGHANIAL A. GENERAL CONDITIONS 1. Drawings and general provisions of contract, Including general and supplementary conditions and all other specification sections are a part of this contract and apply to this and the other sections of Division 15. 2. The contractor for this work is required to read the entire specifications and review drawings for ail other trades. 3. The contractor is responsible for providing his subcontractors with a full set of bid set documents (including specifications) and the coordination of his work and inspections and the work and inspections of his subcontractors with all other trades on site conforming to the general contractor's time schedule. 4. The contractor shall visit the site prior to submitting his bid to determine conditions affecting the work. Bids shall serve as evidence of knowledge of existing conditions and any modifications which are required to meet the intent of the drawings and specifications. Failure to visit the site does not relieve the contractor of responsibility in performance of work. 5. Wen used, the term "provided by contractor" shall be as meaning "furnished d and Installed" with the exception where items are "provided by tenant" which means "Furnished only" (installed by contractor), except as specifically noted otherwise. B. GENERAL REQUIREMENTS 1. The Contractor shall provide all labor, materials, equipment, services, tools, transportation, incidentals and details necessary to provide a complete and fully functional mechanical system as shown on the drawings, called for In the specifications, and as required by job conditions. All work not specifically noted as being by the landlord shall be provided by the mechanical contractor. Closely coordinate the entire installation with the landlord, as required. Field verify the exact type, size and location, etc. of existing pipe and ducts in the tenant space prior to bid. 2. The drawings and speciFications are intended to supplement each other and any material or labor called for in one shall be provided even though not specifically mentioned in both. Any material or labor which is neither shown on the drawings nor called for in the specifications, but which is obviously necessary to complete the work, and which is usually included in work of similar character, shall be provided as part of contract. 3. Where the drawings or specifications call for items which exceed codes or the landlord's tenant criteria, the contractor is still responsible for providing the system as designed and described on these drawings, unless specifically noted otherwise. 4. All mechanical work shall be installed so as to be readily accessible for operatng, servicing, maintaining, and repairing. The contractor is responsible for providing sufficient access to all equipment for service. 5. The contractor shall do all cutting, core drilling, chasing or channeling and patching required for any work under this division. Gutting shall have prior approval by the tenant's construction manager and the landlord. Patching shall match, finish or surrounding area. G. CODES I. All work shall be performed in a neat professional manner using good engineering practices. All work shall conform to the landlord's criteria, the stote's, county's, city's and local codes and ordinances, saFety and health codes, NFPA codes, energy codes and all other applicable codes and requirements. The contractor shall inquire into and comply with all applicable codes, ordinances, and regulations. After contract is issued, no additional cost due to code issues shall be reimbursed by the tenant to the contractor. D. LICENSES, PERMITS, INSPECTIONS d FEES 1. The contractor shall obtain and pay for all licenses, permits, Inspections, and Fees required or related to his work. 2. Furnish to the tenant's construction manager all certificates of inspection and final inspection approval at substantial completion date of project. E. DRAWINGS 1. Drawings (plans, specifications, and details) are diagrammatic and indicate the general location and intent of the mechanical systems. Because of the small scale of the drawings, it is not possible to indicate all duct and piping offsets, fittings and accessories that may be required. 2. The layout shown on the drawings Is based on a particular make of equipment. If anther make of equipment is used which requires modification or change of any description from the drawings or specifications, the contractor shall be responsible as part of this work, for making all such modifications and changes, including those involving other trades with the cost thereof Included in his bid. In such case, contractor shall submit drawings and specifications prior to starting work showing all such modifications and changes. His proposal shall be subject to the approval of the tenant's construction manager. F. EXISTING SHELL SPACE CONDITIONS I. The contractor shall be responsible for the coordination of the demolition of existing mechanical work shown on the mechanical drawings and the mechanical demolition shown on the architectural drawings. 2. The contractor shall include, and will be held responsible For, the removal of all existing fire protection, plumbing fixtures, piping, HVAG units, refrigerant recapture, exhaust fans, etc. and associated roof curbs not to be reused on this project, unless specifically noted otherwise. Contractor must verify with the landlord all presumed abandoned equipment, pipes, ductwork, and equipment prior to removal. Roof curbs shall be removed and the roof patched unless noted for reuse or reconfiguration on plans. -Roof patching shall be performed at the contractor's expense by a roofing contractor approved by the landlord. All extraneous items in the space or on the roof (above this space) not applicable to the new work or part of the landlord's or another tenant's active system must be removed and roof/wall/floor/patched/repaired to match existing structure. Existing abandoned pipes, ducts, or equipment in the floor, embedded in concrete, or otherwise inaccessible are to be cut off and sealed below or within floor or wall level when they are not to be reused In this project. If required by landlord or codes, abandoned piping and/or ductwork must be removed to point of origin. Confirm the extent of demolition prior to bid and include in bid proposal. 3. Active landlord or other tenant services encountered in work shall be protected and supported. if existing services not anticipated require relocation, contact the tenant's construction manager immediately. All costs for repair of damages to active landlord or other tenant services during construction shall be paid For by the contractor causing the damage. 4. Tie-ins and modifications to existing landlord services must be done with minimum interruption of landlord operation and during hours specified by the landlord. The contractor is responsible for confirming exact working hours of this work with the landlord prior to submitting his bid. The contractor shall include in his bid, all premium time required to perform modifications during other than normal working hours. All such work must be coordinated with the landlord. P N I DOCUMENTS G. DISGRE A G E5 IN DOGU E 5 I. Drawings (plans, specifications, and details) are diagrammatic and indicate the general location and intent of the mechanical systems. Where drawings, existing site conditions, specifications or other trades conflict or are unclear, advise the general contractor in writing, prior to submittal of bid. The general contractor is responsible to advise the tenant's construction manager, in writing, of variations to contract documents prior to submission of bid. Otherwise, tenant's construction manager's interpretation of contract documents or conditions shall be final with no additional compensation permitted. H. TRADE NAMES AND MANUFACTURERS I. Where trade names and manufacturers are used on the drawings or in the specifications, the exact equipment shall be used as a minimum standard for the base bid. Manufacturers considered os on equal or better in all aspects to that specified will be subject to approval in writing by the tenant's construction manager prior to acceptance. The use of any unauthorized equipment shall be subject to removal and replacement at the contractor's expense. I. SHOP DRAWINGS I. Submit six copies of material lists and shop drawings for all equipment and duct Fabrication drawings to the tenant's construction manager for approval prior to ordering equipment. Submissions must be eddy enough to allow the tenant's construction manager eight working days for review without causing delays or conflicts to the job's progress. Submittals shall be in accordance with the general conditions using the manufacturer's listed on the drawings. Shop drawings shall include all data that pertains to the requirements set forth on the drawings and in the specifications. The submittal shall include but not limited to cuts or catalogs including descriptive literature and characteristics of equipment shall show major dimensions, roughing -in data, capacity, curves, pressure drop, code compliance, motor and drive data and electrical data. Observe special instructions when required. Submittals shall bear the stamp of the general and sub -contractor showing that he has reviewed and confirmed that they are in conformance with the contract drawings and specifications or indicate where exceptions take place. Lack of such contractor's review and approval will be cause for rejection without review by tenant's construction manager. All shop drawings must appear in the operation and maintenance meals left on site at job completion. 2. Tenant's construction manager's review of shop drawings or schedules shall not relieve the contractor from responsibility For errors, omissions or other deficiencies or deviations in the shop drawing from the contract drawings and specifications. J. RECORD DRAWINGS I. The contractor shall maintain one copy of drawings and specifications on the job site to record deviations from contract drawings, such as: a. Location of concealed piping valves and ducts. b. Revisions, oddendums, and change orders. c. Significant deviations made necessary by field conditions, approved equipment substitutions, and contractor's coordination with other trades. d. Exact routing of all sanitary and domestic water piping under Floor. 2. At completion of the project and before Final approval, the contractor shall make any final corrections to drawings and certify the accuracy of each print by signature thereon. The drawings are to be turned over to the tenant. K. GUARANTEE 1. The contractor shall guarantee all materials and work under his contract and shall make good, repair or replace at his own expense, any defective work, materiI, orequipment which ma y be discovered within a period of 12 months from the date of acceptance (in writing) of the Installation by the, tonant's construction manager. Provid e extended warranties as specified with individual equipment. in case of replacement or repair of equipment due to failure within guarantee period, guarantee on that portion of work shall be extended for a period of one (1) year from date of such replacement or repair. L. OPERATIONS MANUALS I. One copy of each Operation and Maintenance Manual for all equipment furnished on job shall be collected and Inserted in a 3" three ring binder and turned over to the tenant. Each notebook shall include but not be limited to installation, maintenance and operating instructions, pamphlets or brochures, approved shop drawings and warranties obtained from each manufacturer of principal items of equipment. M. SLEEVES I. The contractor shall provide sleeves to protect equipment or facilities in the installation. Each sleeve shall extend through its respective floor, wall or partition and shall be cut flush with each surface except sleeves that penetrate the Floor, which shall extend 2" above the floor. 2. All sleeves and openings through fire rated walls and/or floors shall be fire sealed with calcium silicate, silicone "RTV" Foam, "3M" Fire rated sealants or equal, so as to retain the fire rating of the floor or wall. Conform to U.L. assembly rating of Floor or wall. 3. Sleeves in bearing and masonry walls, floors, and partitions shall be standard weight steel pipe finished with smooth edges. For other than masonry partitions, through suspended ceilings, or for concealed vertical piping, sleeves shall be No. 22 U.5.6. galvanized steel minimum. 4. Duct sleeves to be minimum 14 gauge steel. N. HANGERS I. Hangers shall include all miscellaneous steel such as angle iron, bands, G-clamps with retaining clips, channels, hanger rods, etc., necessary for the installation of work. 2. Hangers shall be Fastened to building steel, concrete, or masonry, but not to piping or ductwork. Hanging from metal deck is not permitted. Hangers must be attached to bottom chord of bar joist. Where interferences occur, In order to support ductwork or piping, the contractor must install trapeze type hangers or supports which shall be located where they do not Interfere with access to fire dampers, valves, occess doors and other equipment service requirements and/or other trades. Hanger types and Installation methods are subject to landlord criteria. 3. Hangers for all insulated piping shall be sized and installed for the outer diameter of insulation. Install 6" long split circle galvanized saddle between the hanger and the pipe insulation. 4. Hangers and piping of dissimilar metals shall be di -electrically separated From one another. O. ACCESS DOORS I. Furnish steel access doors and Frames, minimum 16" X 20" or as shown on drawings, to general contractor For all locations where necessary to provide access to concealed valves, and other equipment requiring service or inspection. Location, type, size and number as determined by contractor and approved by tenant construction manager to suet equipment requirements. General contractor will install access doors and frames. 2. Access doors located in fire -rated walls, floors, ceiling -floor or ceiling -roof assemblies shall be We rated, Underwriter's Laboratories, Inc., listed and labeled. 3. Access doors shall be flush type; manufactured from No. 14 gauge steel, complete with Flush flange type Frames manufactured from No. I6 gauge steel, provided with anchors. Access doors shall be suitable from installation in wall or ceiling materials shown in room finish schedules. P. ELECTRICAL MOTORS 1. Furnish, Install and align all motors required for this equipment. Unless they are factory installed on the unit, all starters and associated wiring and safety switches for such motors shall be Furnished and installed by the electrical contractor. Starters shall meet all requirements os defined in the electrical division of the specifications. 2. Design, construction and performance characteristics of motors shall conform to all applicable provisions of latest NEMA, AN51, I5EE standards for electrical equipment. All motors shall be suitable For operation on voltage variation of plus or minus 10%, 40 degrees G operation on voltage variation of plus or minus 10%, 40 degrees C. ambient temperature; have a service Factor of not less than 1.15. Q. LOW VOLTAGE (24 VOLT) WIRING I. The contractor is to install all low voltage wiring required for his equipment. This work includes all transformers and devices to make this a complete Functional system. 2. All work is to conform to the latest addition N.E.G. aid to Division 16 electrical specifications. 3. Any conduit required by code or the landlord will be installed by the electrical subcontractor. SECTION 15500 - HEATING, VENTILATION, AND AIR CONDITIONING A. SCOPE OF WORK 1. The HVAG contractor shall furnish all labor, materials, equipment, services, tools, transportation and facilities necessary For, reasonably implied and incidental to, the furnishing, Installation, completion and testing of all the work for the mechanical systems as shown on the drawings, called for in the specifications, and as required by job conditions, to include, but not be limited to the following: (Refer to responsibility schedule for exact responsibilities). a. HVAG units, equipment, and appurtenances. b. Ductwork, fittings, dampers, and insulation. c. Hydronic piping and insulation (as applicable, refer to plans). d. -Refrigerant piping (as applicable, refer to plans). e. Diffusers, grilles, and registers. F. Curbs and steel framing for support (as applicable, refer to plans). g. Testing, adjusting, and balancing. h. Operations Manuals. 1. Temperature controls and related diagrams. J. Sequences of Operation. k. Connection to any landlord energy management system. 2. Before starting work, this contractor shall examine the architectural, structural, mechanical and electrical plans and specifications to sequence, coordinate, and integrate the various elements of the HVAG system, materials, and equipment with other contractors to avoid interferences and confrontations. B. HVAG EQUIPMENT 1. Primary Heating, Ventilation, and Air Conditioning Units. a. Primary heating, ventilation, and air conditioning units are to be as scheduled. All compressors are to include a 5-year extended warranty. b. Equals equipment as manufactured by Carrier r Y rk IF not available through reasonable effort. t. c. All equipment shall be complete in every respect with all devices, appurtenances, and accessories provided to meet the design intent and operation of the systems shown on the drawings and specified herein. d. Equipment shall be installed in strict accordance with the manufacturer's instructions. All air conditioning equipment must have a condensate drain and be trapped in accordance with manufacturer's data. See drawings for additional details. e. Secondary drain pans are required to be installed beneath all indoor air conditioning equipment with the exception of VAV boxes. Secondary pans are to protect entire unit. Provide condensate pumps, as required. Condensate shall be directed to mop sink or as specified on plans. 2. Variable Air Volume (VAV) Boxes if Applicable a. Where shown on drawings; provide VAV boxes complete with controls, heating coils (Fans as required). All duct connections flexible duct/pipe connections shall be provided by the contractor. 3. Toilet Exhaust Fans a. Where shown on drawings, provide a toilet exhaust fan unit complete with gravity back draft dampers. All ductwork, roof openings and caps necessary to provide a complete exhaust system shall be provided by the contractor. Refer to plans for applicability. 4. Baseboard, Cabinet, and Unit Heaters a. Where shown on drawings, provide electric heaters complete with electric. heating coil, controls, and integral thermostat. 5. Vibration Isolation Devices a. Vibration isolation devices shall be provided in all supports between vibrating equipment (fans, rooftop units, air handlers, fan powered VAV boxes, etc.) and structure. b. Vibrating equipment hung from structure shall be isolated with rubber and spring devices. Vibrating equipment supported from floor or deck shall be isolated with housed spring mount devices. c. Examine dead load and operating load conditions when selecting devices. Adjust for proper alignment and loading. Avoid "grounding" the isolator. d. Check hanger rod size for allowable loads at the isolating device and at the upper and lower attachments to structures, ducts, equipment, etc. e. Consult manufacturer For application data. G. METAL DUCTWORK - No Fiberglass Duct Allowed I. No ductwork shall be fabricated prior to approval by the tenant's construction manager. Significant deviations from design must be approved by tenant's construction manager prior to fabrication or installation. All duct mains are to be rectangular unless notes otherwise. All duct branches to diffusers are to be round rigid duct. (Flexible duct connections to the diffuser are not to exceed 4'-0"). 2. Except as otherwise indicated, fabricate and install rectangular ducts with galvanized sheet steel, in accordance with 5MAGNA 'HVAG Duct Construction Standards" of the latest edition. Conform to the requirements to the referenced standard For metal thickness, reinforcing types and intervals, the rod applications, and joint types and intervals. 3. Except where otherwise indicated, construct duct systems to the Following pressure classifications: (Verify whether return or exhaust duct is positive or negative pressure). a. Supply Ducts: 2" water gauge, positive pressure. b. 'Return and Exhaust Ducts: 2" water gauge, negative pressure. Pressure test ducts for leakage. Remake leaking joints and apply sealants as required to fabricate a system that does not exceed 5% leakage or less as stated by pressure class ratings in 5MAGNA standards. 4. As a minimum, crossbreak all flat surfaces or reinforce with a bead approximately 3/&" wide x 3/16" deep on 12" centers to prevent vibrations. 5. Install double thickness turning vanes in all right angle elbows. 6. Install rigid round and rectangular metal duct with support systems indicated in 5MAGNA standards. Support horizontal ducts within 2 feet of each elbow and within 4 feet of each branch intersection using double strap hangers on each side of fitting. Support vertical ducts at a maximum interval of 16 Feet and at each floor. No wood shall be used to support or brace ducts. Provide sway and seismic bracing as required by state and local codes or by landlord. -7. Where ducts pass through roofs and floors, provide as minimum 1-1/2" X 1-1/2" X I/b" steel angle frames at each side of opening. The annular space between duct and angle fromes shall be caulked with silicone sealant or fireproofed as required by assembly fire rating. 8. All traverse joints and seams in supply air duct shall be sealed air tight with DAP GMG duct sealer. Joints also shall be riveted or connected with sheet metal screws. 9. Soft elostomer butyl gasket with adhesive backing shall be used to seal Flanged joints. 10. Duct transitions shall not exceed 30 degrees slope except as specifically noted otherwise. 11. Provide access to all motorized dampers, fire dampers, controls, and other items in ductwork that require service or inspection. If the access panel location is exposed to the sales area, it must be approved by the tenant's construction manager prior to installation. Lay -in supply and return air diffusers, grilles and registers with plaster frames may be used as access locations. 12. Flexible Connections a. Flexible collars shall be provided in all connections between vibrating equipment (fans, rooftop units, air handlers, fan powered VAV boxes, etc) and ducts or casings. Also, provide flexible connections where ducts cross building expansion joints. b. Flexible connections shall be constructed of neoprene -coated flameproof fabric. Provide adequate Joint flexibility to allow for movement and prevent the transmission of vibration. c. Flexible connection is to be rated for the operating pressure of the system. 13. Fire Dampers a. Provide primary fire dampers where indicated or required by codes. Dampers shall be designed for horizontal or vertical flow of air as required. Fire dampers shall be UL labeled. b. Fire dampers shall have the blades out of the airstream and a 165"F fusible link, Type A, as minimum. c. Provide all necessary framing and sleeves for damper mounting per UL and code requirements. d. Provide duct access doors in on accessible location for ail fire dampers. Door is to be 20 6A galvanized door with quick -opening latch and pion hinge. 14. Flexible Air Duct a. Flexible air duct shall be I" insulated Glass I and rated for the operating pressure of the system. Duct construction material (plastic, cloth, aluminum) must adhere to local codes and landlord's requirements and be Included as such in the bid. b. Flexible air duct may only be used in vertical applications with prior approval from tenant's construction manager. c. Flexible duct shall not extend over 4'-0" in length at any one location. 15. Supply Air Take -Off Fittings a. Provide conical or "Bell -Mouth" take -offs from main ductwork to round branches. Install per manufacturer's Instructions. b. Provide 45" rectangular take -offs from main ductwork to rectangular branches. 16. Dampers a. Provide manual locking quadrant volume control dampers with handle operators in each branch duct and as shown on plans to Facilitate air balancing. b. Where access to balancing damper is restricted, Young's regulator shall be used. c. All rectangular dampers in outside air, relief air, or return air ducts are to be of opposed blade type. All outside air duct dampers must also be of the low leakage type. d. All motorized dampers not furnished with equipment are to be Honeywell dampers. 11. Diffusers, Grilles, and Registers a. Provide diffusers grilles and registers as scheduled. Devices to be complete with dampers frames and all accessories. Finish as indicated. b. Install all air devices as located on the architectural reflected ceiling plan. c. Approved manufacturers: Titus is specified, equals by Metololre or Krueger is acceptable. 16. Low Pressure Duct a. Where ductwork is 5peciFicolly noted as low pressure, it shall be constructed in accordance with 5MAGNA standards forpressure r ting of 3 inches es water Column minimum or larger as required by landlord. b. All gauges and reinforcement must meet with the latest edition of 5MAGNA standards For low pressure duct and with the landlord's criteria. c. All other items from metal ductwork specification section apply to this section. Iq. Ductwork Insulation a. Install insulation products in accordance with manufacturer's writien Instructions, and in accordance with recognized industry practices. Insulation must comply with NFPA cIOA. b. Duct sizes shown on drawings are inside clear dimensions. Insulate supply and return air rectangular ductwork. Ductwork shall be internally insulated with I' thick, 1-1/2" lb. density liner (0=0.25 e '75"F). Liner is to have a coated surface exposed to airstream to prevent erosion. Apply adhesives and mechanical fasteners as recommended by 5MAGNA and the manufacturer to prevent liner separation from the duct. All transverse edges to be coated with adhesive. c. All round and outside air ductwork above the ceiling shall be externally insulated with a minimum of I" thick, 1-1/2 lb. density (R=5.6) duct wrap with vapor barrier. Vapor barrier is to be maintained throughout duct system. All joints must be taped so that no insulation fiber is visible. Extend ductwork insulation without interruption through walls, floors, and similar penetrations. d. All insulation shall have a flame spread rating of not more than 25 and a smoke developed rating of no higher than 50 when tested in accordance with A5TM G 411, or as required by local codes. 20. System Gleonout a. Ductwork and air handling equipment is to be cleaned out and blown out before painting is started by the general contractor. b. Filters must be in units at any time fans are operated. 6. HVAG INSPECTIONS I. Aside from normal interim inspections of work in place, the tenant shall have the right to an independent HVAG contractor inspect the finished HVAG installation upon completion for compliance with the plans, specifications, and codes. The installing contractor will be responsible to bring all items reported by the independent HVAG contractor up to plans and specification requirements at no cost to tenant. H. PROJECT TURN OVER I. The HVAG contractor shall replace all air filters the day the space is turned over to the tenant and again 14 days after turn over. This work shall be scheduled and coordinated with the store manager. 2. The contractor shall provide I year supply of filters and warranty on filter replacement. F 6 o Gs pL%PN CC pQ G EO A 16 tip1` Mai ir1 0 1u AS 1904 OON G RECEIVED CITY OF TUKWILA FEB 2 6 2015 M'TJK0AMtE b. PERMIT AND APPROVAL ry UJ z I ry i- Q } Z <C W Q l{1 m Q W X W_ ? QL O Z H v W Q[ L1 Z Z Z OL 3 a O > m ig W _ p 66 (IF^_ W 0 Lf) W d mrym ryryN J W N U Z W L.i • 1..1 LL ASSOCIATES II, L.L.C. 281 Farmington Avenue Farmington, CT. 06032 SHEET NO. i �n EX. 150A MCB 208/120V PANEL - - - EX. 45KVA TRANSFORMER I I I I - 2t� EX. IOOA/3P, 480V FUSED SERVICE SWITCH I I I I = - _ _ - _ - _ _ - - - _ _ - _ II II �_/� 1 �, ` EX. TENANT TELEPHONE SERVICE I u I EXISTING VAV TO 1 1 1 REMAIN; RE -TERMINATE n n I I EXISTING BRANCH d I I I I I I I I CIRCUIT AS INDICATED I d I I I I I I I L IN LP PANEL SCHEDULE 11 II I I I I I I - - - - - - � II 11 I I I I I Ii - - - -- III �I u u u 11 �� II II I I II cil Oil I I I I I I I �I I I II C)l dll L-------1� I I II l l u I I III III Il II II II oil oil \ I I 11 r - -I 11 I I I III 11 I1 u I - -!j u ELECTRICAL PEMOL I TION PLAN SCALE: I/4" = I'-O" - - 9- - -9- - �L - -/ - - ==6==4s===6==e==�S==&=_ KEYED NOTES: O INTERIOR LIGHTING FIXTURE5, HVAC MOTORS DISCONNECT, ROOF MOUNTED EQUIPMENT, POWER DEVICES AND LOW VOLTAGE DEVICES AND EQUIPMENT SHALL BE REMOVED IN THEIR ENTIRETY, UNLESS SPECIFICALLY NOTED OTHERWISE. REMOVE ASSOCIATED WIRE, CONDUIT, FITTINGS, HANGERS, SUPPORTS, ETC. ABANDONED WIRING SHALL BE REMOVED. O EXISTING EQUIPMENT SHALL REMAIN. O3 EXISTING BACKBOARD SHALL REMAIN. ELECTRICAL DEMO - GENERAL NOTES I. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL NATIONAL, PROVINCIAL, LOCAL CODES d ORDINANCES. 2. DEMOLISHED MATERIAL SHALL BE CONSIDERED TO BE THE PROPERTY OF THE CONTRACTOR AND SHALL BE COMPLETELY REMOVED FROM THE JOB SITE, UNLE55 OTHERWISE NOTED. 3. THIS DRAWING DOES NOT DEPICT THE FULL EXTENT OF DEMOLITION. ADDITIONAL ITEMS SCHEDULED FOR DEMOLITION MAY BE FOUND ON OTHER DRAWINGS. GENERAL CONTRACTOR 15'RE5PON5113LE FOR THE COORDINATION OF THI5 WORK WITH ALL PARTIES INVOLVED. 4. DEMOLITION CONTRACTOR MU5T VERIFY LOCATIONS OF ALL EXI5TING STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION 8 ELECTRICAL ELEMENTS PRIOR TO START OF DEMOLITION. 5. REMOVE ALL ELECTRICAL LIGHTING FIXTURES, ELECTRICAL RUNS, ASSOCIATED DEVICES. -REFER TO ELECTRICAL DRAWINGS FOR -RELATED INFORMATION AND NEW WORK. b. REMOVE ALL EXISTING CEILING 5Y5TEM5 IN THEIR ENTIRETY INCLUDING SUSPENSION SYSTEMS AT ALL AREAS WHICH ARE SCHEDULED FOR NEW CEILINGS. 1. IF, DURING THE COURSE OF DEMOLITION, ANY ASBESTOS MATERIAL 15 SUSPECTED, ALL WORK 15 TO STOP IMMEDIATELY AND THE OWNER AND THE DESIGNER ARE TO BE NOTIFIED. 8. REMOVE ALL CEILING MOUNTED MECHANICAL FIXTURES AS SCHEDULED. REFER TO MECHANICAL DRAWINGS FOR -RELATED INFORMATION AND NEW WORK. 9. FLOOR PLANS BASED ON "A5-BUILT" DRAWINGS. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, FOR ACTUAL DEVICE TYPE, NUMBER AND LOCATIONS. 10. DEVICES WITH THE INDICATOR "ER" ARE EXISTING TO REMAIN EXISTING WIRING TO -REMAIN. 'RE -CIRCUIT AS INDICATED ON DRAWINGS ELI AND E2.1. II. HVAC UNITS SERVICING THE TENANT SPACE SHALL BE DISCONNECTED AND WIRING AND CONDUIT -REMOVED BACK TO THE PANEL. CONTRACTOR SHALL VERIFY UNITS 5ERVICING THE MALL SPACES. REVIEWED FOR CODE COMPLIANCE APPROVED i OR 16 2015 City NG p v11SI0N BUILD RECEIVED CITY OF TUKWILA FEB 2 6 2015 PERMIT CENTER ELECTRICAL DEMO - CONTRACTOR NOTES I. VERIFY LIMITS OF DEMOLITION AND REQUIREMENTS WITH LANDLORD. 2. COORDINATE ALL DEMOLITION WITH LOCAL MALL OPERATIONS MANAGER. 3. ANY RE -USED MATERIAL AND EQUIPMENT MUST BE REFURBISHED TO A "LIKE NEW" CONDITION. 4. DO NOT ABANDON ANY UTILITIES OR MATERIALS WITHIN THE LEASE SPACE. REMOVE BACK TO THE SOURCE. 5. COVER RETURN AIR OPENINGS BEFORE AND, DURING CONSTRUCTION AS REQ'D. 6. DEMOLITION CONTRACTOR SHALL REMOVE MECHANICAL EQUIPMENT, ALL ASSOCIATED HARDWARE, DUCTWORK, DIFFUSERS, GRILLES, PIPING, AND RELATED HANGERS AS INDICATED ON DRAWING MI.I. THE SPACE SHALL BE LEFT GLEAN AND FREE OF DEBRIS. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE 51TE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. TH15 CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HI5 BID ALL C05T5 TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR B105 THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND 5PECIFICATION5 NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT 0I5CREPANCIE5 BETWE GOVERNING CODES AND DE516N INTENT.: '4 REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFO ATION. THERE BE NO CONSIDERATION FO} ORD�FOR N&OW AT10N FO�,0bWARChWEa= 1 N ry m O QI o - z Q m .. }. m p O z LU z w w LU < v w O � CL w`�ia w too % w _( LLJ lu UJ Q Lf) Lf)� mryry V ryryry z a a J d W N N W W z_ z W L.L. ■ N� L.J.. U. ASSOCIATES II, L.L.C. 281 Farmington Avenue Farmington, CT. 06032 on-Recucled 1 V EXISTING CORRIDOR .22 �1+ r G G G 15 LIGHTING CONTACTORS P-31 to EX. PANEL LP LP-34 I6 EX. TRANSFORMER to EX. 480V SERVICE SWITCH WA LP-1 STOCK ROOM 4 003 NEW TELEPHONE CONDUIT STUB FROM LL CORRIDOR EXISTING VAV TO GABLE TRAY TO TENANT SPACE. PROVIDE 12 PAIR REMAIN, RE -TERMINAL 5 PLENUM RATED TELEPHONE GABLE FROM TENANT EXISTING BRANCH TELEPHONE EQUIPMENT TO LANDLORD'S MAIN TEL. LP CIRCUIT AS SERVICE DISTRIBUTION; COORDINATE WITH LOCAL 5CHHEDULEOULE TEI TELEPHONE COMPANY AND LANDLORD IN PANEL S- F VI "1518 FA CONTROL MODULE FOR SOUND 75 18 SYSTEM SHUTDOWN ON FA ACTIVATION LP 2830 � VAV 2 18 � �Sf LP-36 `\ 1 E � r �� z LP 23 TO LIGHT 000�' SWITCH EX� LP-1 5 TOILET'ROOM [SAFE �iO4� a I c 1 !'III WITTIl i! q 1 ,! LP-40 II G G � � I J i COORDINATE WITH 4 I LANDLORD FOR LP-q GUTTING OF FLOOR. 4 `i X-RAY FLOOR BEFORE LP-11 GUTTING (TYPJ. PROVIDE LP-Iq,21 THREE (3) CONDUITS AS I SEE GA5HWRAP POWER SHOWN. �! I PART PLAN ON THIS DRAWING F FOR WORK IN THI5 AREA AV -I 18 4 '7 LP-3q 13 LP-1 G LP-3`I n � � LP- J II o NEW 100NER 4 FIRE ALARM PLAN SCALE: 1/4"= I'-O" ELECTRICAL 51'M50L5 ALL SYMBOLS DO NOT NEGE55ARILY APPLY 5YM130L DESCRIPTION MOUNTING HEIGHT TO CENTERLINE UNLESS OTHERWISE NOTED © WALL MOUNTED JUNCTION BOX SEE DRAWINGS al GEILIN6 MOUNTED JUNCTION BOX CEILING me DUPLEX -RECEPTACLE, 3 WIRE &ROUND. TYPE, 20A 18" UNLESS NOTED OTHERWISE MOO DUPLEX -RECEPTACLE, 3 WIRE &ROUND. TYPE, 20A 120 BELOW COUNTER Mole DUPLEX RECEPTACLE, ISOLATED GROUND. TYPE, 20A 15" UNLE55 NOTED OTHERWISE New p DUPLEX RECEPTACLE, WEATHERPROOF,20A IS" UNLE55 NOTED OTHERWISE �6F1 GROUND FAULT PROTECTED DUPLEX RECEPTACLE, 20A 42" UNLESS NOTED OTHERWISE QUADRAPLEX WALL RECEPTACLE, 20A 18" UNLE55 NOTED OTHERWISE •� SPECIAL PURPOSE RECEPTACLE AS REQUIRED • O FG FLUSH MOUNTED DUPLEX RECEPTACLE, 20A F - FLOOR G - GEILIN6 AS REQUIRED �q D POWER/DATA OUTLET w/ RECE55ED FACE PLATE. SUBSCRIPT INDICATES THE QUANTITIES OF: DUPLEX RECEPTACLES (P) d DATA (D) ACTIVATION FITTINGS. (Ex: 2,3 = 2 DUPLEX RECEPTACLES d 3 DATA) FLOOR ED LOW VOLTAGE BUZZER TRANSFORMER AS REQUIRED M DOOR CHIME AS NOTED S S3 Sr TOC76LE SWITCH - 51NGLE, 3-WAY, MOTOR -RATED 48" SM PU5HBUTTON STATION 42' Q2 DATA OUTLET - (2) CATEGORY 6 VERIFY MOUNTING HEIGHT w/ OWNER Q 1 DATA OUTLET - (1) CATEGORY 6 VERIFY MOUNTING HEIGHT w/ OWNER Q4 DATA OUTLET - (4) CATEGORY 6 VERIFY MOUNTING HEIGHT w/ OWNER 208 / 120V POWER PANELBOARD EXISTING 2T1 / 480V POWER PANELBOARD EXISTING EXISTING C� SAFETY SWITCH AS REQUIRED 4 MOTOR AS REQUIRED MOTOR STARTER AS REQUIRED — — — — CONDUIT CONGEALED UNDER FLOOR �- HOME RUN TO 120 VOLT PANELBOARD M FIRE ALARM MANUAL PULL STATION 48" E15 FIRE ALARM VISUAL 516NAL DEVICE w/ CANDELA # 80' M4 -* FIRE ALARM AUDIOVISUAL SIGNAL DEVICE w/ CANDELA # 80' GEILIN6 MOUNTED FIRE ALARM AUDIOVISUAL 516NAL DEVICE GEILIN6 4s SMOKE DETECTOR CEILING MOUNTED 4 HEAT DETECTOR CEILING MOUNTED ® FIRE ALARM 5UPERV15ORY SWITCH AS REQUIRED RELAY AS REQUIRED r� TIME CLOCK AS REQUIRED 8 DUCT SMOKE DETECTOR AS REQUIRED r TEST SWITCH l2" �i FIRE ALARM CONTROL MODULE A5-REQUIRED Mo GALL -FOR -AID AUDIO/VISUAL INDICATING DEVICE ABOVE DOOR FRAME Mpc- GALL -FOR -AID PULL CORD SWITCH -REFER TO DETAIL 3, DVS. E3.1 I II SALES FLOOR I 002 • ,4 � l G1 COORDINATE WITH LANDLORD FOR CUTTING OF FLOOR. X-RAY FLOOR BEFORE CUTTING (TYPJ. SPARE 21 %\ PROVIDE CONDUITS A5 LP-5 SCHEDULED. LP 26 J LP-15 12 18 5 EN 18 ` OOI - COORDINATE WITH LANDLORD FLOOR. X-RAY FLOOR BEFORE GUTTING (TYP). PROVIDE THREE (3) CONDUITS AS /-1--ft- IMMAIII��((00��a 1 13 a I NO' "f-I �' 10 �!D cf-001 0�=V I I LP-1-1 POWER GENERAL NOTES I. REFER TO MECHANICAL PLAN FOR LOCATION OF MECHANICAL EQUIPMENT. FIELD VERIFY EXACT 1 I LOCATIONS. 2. ELECTRICAL CONTRACTOR TO PROVIDE TYPED PANEL DIRECTORY WITH ALL CIRCUITS ACCURATELY 4 DESCRIBED PRIOR TO STORE OPENING. 3. ALL RECEPTACLES AND COVERPLATE5 SHALL BE WHITE IN COLOR. ' 4. ALL CONDUITS SHALL BE CONGEALED IN WALLS AND OUTLET BOXES SHALL BE FLUSH WITH FINISHED WALL UNLESS OTHERWISE NOTED. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES AND ORDINANCES. / 5. ALL NEW WORK SHALL BE INSTALLED CONGEALED, UNLE55 OTHERWISE NOTED. / 6. CONTROLS AND OPERATING MECHANISMS: THE HIGHEST OPERABLE PART OF ALL CONTROLS, DISPENSERS, 2 RECEPTACLES AND OTHER OPERABLE EQUIPMENT SHALL BE PLACED WITHIN 48" OF THE FLOOR BUT NOT or LOWER THAN 15" IF FORWARD APPROACHED AND WITHIN 54" BUT NOT LOWER THAN q" IF 51DE a I APPROACHED. 1 1. ELECTRICAL AND TELEPHONE WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL FEDERAL, I Avg STATE AND CITY ELECTRICAL CODES; AND THE LANDLORDS CONSTRUCTION GUIDELINES. 2 8. G.G. SHALL PROVIDE 3/4" CONDUIT TO EACH DATA OUTLET BOX AND TO ANY OTHER EQUIPMENT THAT WOULD REQUIRE A GABLE FEED FROM OUTLET TO IT RACK. ALL CONDUITS TO INCLUDE DRAG LINES. ALL CONDUIT -RUNS BY G.G. FOR L16HTINC, POWER, DATA OR LOW VOLTAGE TO EMERGE FROM FURRED -OUT I DEM151NC WALLS OR NEW PARTITIONS, AND BE RUN IN A GLEAN, MINIMAL LAYOUT. q. ALL RECEPTACLES ARE TO BE GROUNDED AND TO RECEIVE STANDARD 3-PRONG PLU655, UNLE55 ` VOLTAGE, AMPERAGE OR SPECIFIC NOTATION GALLS FOR A SPECIFIC TYPE OF -RECEPTACLE. 10. SHOULD JOB CONDITIONS REQUIRE RELOCATION OF PLANNED TELEPHONE OR ELECTRICAL OUTLETS FOR 1 ANY REASON, THE CONTRACTOR SHALL NOTIFY THE DESIGNER FOR APPROVAL OF ALTERNATIVE LOCATION PRIOR TO THE START OF WORK. ' 11. G.G. SHALL PROVIDE ALL THE REQUIRED DRAWIN65, COMPLETED PAPER WORK AND CERTIFICATES OF / INSPECTION FOR ALL THE -REQUIRED MECHANICAL ENGINEERING SYSTEMS (HVAC, SPRINKLER, ELECTRIC, FIRE SAFETY, ETGJ AS REQUIRED FOR LOCAL BUILDING DEPARTMENT APPROVALS. / 2 12. ALL FLOOR OUTLETS TO BE MOUNTED FLUSH WITH RUBBER TILE (FINISH FI) ALL FLOOR OUTLETS TO BE 21 SPARE GORE DRILLED AND PIPED BELOW IN 2NO FLOOR SITUATIONS OR TRENCHED AND PIPED IN SLAB ON GRADE SITUATIONS. G.G. TO VERIFY WITH MALL MANAGEMENT. 1 I 13. CONTRACTOR SHALL PROVIDE CONDUITS AND PULL COR05 FOR TELEPHONE/DATA GABLES. FROM THE OUTLETS TO THE TELEPHONE AND DATA RACKS, TELEPHONE/DATA GABLES SHALL BE INSTALLED BY LECO. In CONDUIT EACH 14. GEILIN6 AREA ABOVE SALES FLOOR IS A PLENUM RETURN SYSTEM. ALL WIRING SHALL BE PLENUM RATED, SUITABLE FOR INSTALLATION IN THIS LOCATION. SEE PANEL 3 15. NO ATTACHMENT OF SUPPORT FROM ANY ROOF DECK PERMITTED. HANGERS, CLAMPS AND SUPPORTS SCHEDULE 3 SHALL BE FASTENED TO BAR JOISTS OR BEAMS ONLY. GASHNRAP PONER PART PLAN 5CALE. 1/2"= I'-O" CASHWRAP CODED NOTES OI 20AMP, 12OV., ISOLATED &ROUND/ DEDICATED CIRCUIT QUADRAPLEX RECEPTACLE (HUBBELL #I6-5362) FOR GASH REGISTERS. DO NOT INSTALL WITH ANY OTHER CIRCUITS. LOCATE RECEPTACLES AT GASH WRAP COUNTER IN51DE CABINET ON CUSTOMER 51DE WALL AS DIRECTED BY OWNER/DE5I6NER. RUN 2 #L2 THWN AND I #I2 6RD. IN I" CONDUIT. GUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT TO WALL. ROUTE UP WALL TO GEILIN6 SPACE AND RUN TO PANEL. O20AMP, 120V., QUADRAPLEX RECEPTACLE AT GASH WRAP COUNTER FOR UTILITY POWER. LOCATE RECEPTACLES AT GASH WRAP COUNTER INSIDE CABINET ON CUSTOMER 51DE WALL AS DIRECTED BY OWNER/DE516NER. RUN 2 #12 THWN AND 1 #12 GRD IN I" CONDUIT. GUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT TO WALL. ROUTE UP WALL TO GEILIN6 SPACE AND RUN TO PANEL. OI" DATA CONDUIT (WITH PULL WIRE) FOR DATA CABLING. GUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT TO WALL. ROUTE DATA CONDUIT UP WALL TO CEILING SPACE AND -RUN TO IT -RACK. O20AMP, 12OV., QUADRAPLEX RECEPTACLE AT GASH WRAP COUNTER FOR UTILITY POWER. LOCATE -RECEPTACLES INSIDE CABINET ABOVE DRAWERS, APPROX. 30" A.F.F., AS DIRECTED BY OWNER/DE516NER. RUN 2 #12 THWN AND 1 #12 &RD IN I" CONDUIT. CUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT TO WALL. ROUTE UP WALL TO GEILIN6 SPACE AND -RUN TO PANEL. FIELD VERI F1' ALL GOND I TI ON5 DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VI51T THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EX15TIN6 FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE DE516NER, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLA6ZIFICATION5 OF THE DE516N AND INCLUDE IN H15 BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE DE516NER, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BI05 THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITH5TANDINC. THE CONTRACTOR SHALL ALERT DE516NER, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. REFER TO ARCHITECTURAL PRAWING5 FOR ADDITIONAL INFORMATION. THERE WILL BE NO CONSIDERATION FOR CHANGE ORDERS FOR INFORMATION FOUND ON ARCHITECTURAL DRAWINGS. POWER CODED NOTES m ED 1 I O O FLUSH FLOOR MOUNTED POWER/DATA OUTLETS 20AMP, 12OV, WITH BRA55 ry 0 FACE PLATES. PROVIDE A RECESSED FLOOR BOX WITH ONE (1) QUAD -RECEPTACLE AND ONE (1) DATA BOX WITH TWO (2) DATA OUTLETS. -RUN 2 .. Q m #12 THWN AND I #12 GRO IN I" CONDUIT FOR POWER. RUN TWO (2) 1" ED Q Z CONDUITS (WITH PULL WIRES) FOR VOICE/DATA CABLING. POWER AND LU ►- TELECOMMUNICATIONS CONDUITS SHALL BE RUN IN FLOOR. GUT AND Z W 3 v PATCH FLOOR AS REQUIRED TO ROUTE CONDUITS TO WALL. COORDINATE < Q W O FLOOR CUTTING WITH LANDLORD PRIOR TO COMMENCEMENT. Q Q ll G 2O RECEPTACLES AND COVER PLATES SHALL BE MOUNTED ON CEILING AT STOREFRONT PARALLEL TO STOREFRONT CLASS. CIRCUIT TO PANEL AS Z - INDICATED. ZO O O3 20AMP, 12OV, ISOLATED &ROUND/DEDICATED CIRCUIT QUADRAPLEX CL W {a� RECEPTACLE (HUBBELL #I6-5362) FOR COMPUTER. DO NOT INSTALL WITH Z j M O ANY OTHER CIRCUITS. RUN 2 #12 THWN, 1 #12 G AND I#I2 I.G. IN 3/4" (3V w CONDUIT BACK TO PANEL. TERMINATE INSULATED ISOLATED GROUND AT — ul PANEL EQUIPMENT GROUND BAR. 0 O RECEPTACLES WITH AN "5F" DESIGNATION SHALL BE 20AMP, 12OV, ,' w in U DUPLEX RECEPTACLE MOUNTED IN WALL ADJACENT TO STOREFRONT AT W I- - - IS" AFF. PROVIDE WHITE RECEPTACLE WITH WHITE COVERPLATE. CIRCUIT n/ 0 M ry ry TO PANEL AS INDICATED. LL - ry O5 ISOLATED 6ROUND/DEDICATE0 CIRCUIT QUADRAPLEX RECEPTACLE FOR Z TELEPHONE SYSTEM. VERIFY SYSTEM GROUNDING AND ALL OTHER REQUIREMENTS WITH LOCAL TELEPHONE COMPANY. MOUNT AT 48" A.F.F.. 0 PROVIDE NEMA L5-3OR TWIST LOCK RECEPTACLE, 3#10, 3/4"C FOR IT EQUIPMENT. VERIFY EXACT EQUIPMENT -RECEPTACLE 'REQUIREMENTS WITH MANUFACTURER PRIOR TO COMMENCEMENT. MOUNT 46" AFF. O JUNCTION BOX FOR RECESSED GEILIN6 SPEAKER. PROVIDE I" CONDUIT WITH PULL 51i RING BACK TO THE IT RACK. COORDINATE EXACT LOCATION AND WIRING REQUIREMENTS WITH DESIGNER. O8 MOUNT DEVICE 34" AFF PROVIDE in CONDUIT IN WALL WITH PULL 5TRINC BACK TO THE IT RACK. O NEW ELECTRIC WATER HEATER. to EXISTING ELECTRICAL SERVICE 5WITCH/PANELBOARD. REFER TO POWER RISER DIAGRAM AND PANEL SCHEDULE ON E3.1. tl INSTALL A DELIVERY CHIME SYSTEM AS SHOWN. SYSTEM SHALL INCLUDE PUSH BUTTON AT REAR DOOR (EDWAR05 #I186-B), CHIME IN NON-5ALE5 AREA (EDWAR05 340-A-65), AND TRANSFORMER (EDWARDS #5612). ALL WIRING SHALL BE IN CONDUIT. O PROVIDE JUNCTION BOX AT GEILIN6 WITH (1) GAT 6 OUTLET AND I" CONDUIT FROM ABOVE THE DOORS AT STOREFRONT TO THE IT RACK W FOR THE FOOTFALL SENSOR. COORDINATE WITH OWNER/DE516NER PRIOR ' TO INSTALLATION, 13 MOUNT DEVICE 2' ABOVE THE EXIT SIGN (-10'-0" ABOVE FINISHED FLOOR) ON THE STOCK ROOM SIDE OF THE WALL FOR WIFI NETWORK. O DATA OUTLET. RUN TWO (2) 1" CONDUITS (WITH PULL WIRES) FOR DATA CABLING. 15 LIGHTING CONTACTORS. SEE LIGHTING CODED NOTES ON SHEET E2.1. c:d 16 EXISTING FLOOR MOUNTED 45KVA TRANSFORMER. REFER TO POWER RISER DIAGRAM ON E3.1. 17 MOUNT RECEPTACLES ON DEMISING WALL WITH IN THE SALES AREA AT 34" A.F.F. CONTRACTOR SHALL WIRE L.E.D. LIGHTING FIXTURE AT BRAND W RIBBON TO OUTLETS. PROVIDE THE FOLLOWING WALLPLATE COVERS FOR ALL RECEPTACLES ON SALES FLOOR COOPER WIRING DEVICES O PRODUCT #TRW15 COLOR - WHITE 18 NEW FIRE ALARM DEVICE. WIRING TIE-IN TO LANDLORD'S EXISTING FIRE ALARM SYSTEM BY LANDLORD'S DESIGNATED CONTRACTOR AT TENANT'S EXPENSE (TYPICAL). COORDINATE ALL WORK WITH LL'S CONTRACTOR. Iq PROVIDE DEDICATED DUPLEX RECEPTACLE FOR REFRIGERATOR. LOCATION TO BE DETERMINED BY OWNER. WIRE TO PANELBOARD CIRCUIT AS INDICATED. t20 PROVIDE DEDICATED DUPLEX RECEPTACLE FOR MICROWAVE. LOCATION TO BE DETERMINED BY OWNER. WIRE TO PANELBOARD CIRCUIT AS (,j] INDICATED. 21 PROVIDE I" EMPTY CONDUIT WITH DRA&LINE TO PANEL "LP". LABEL CONDUIT "SPARE CONDUIT TO CA5HWRAP". �1 © PROVIDE (5) DUPLEX RECEPTACLES. REFER TO DETAIL l/A6.1 FOR MOUNTIN& DETAILS AND WIRING. CONTRACTOR SHALL WIRE LI6HTINC FIXTURE AT BRAND -RIBBON TO OUTLETSrA ©3 TIMEGLOGK/ATTENDANCE EQUIPMENT: MOUNT POWER AND DATA DEVICES AT 48" AFF. DEVICE FURNISHED BY OWNER. 0 HOMERUN THROUGH A 8-POLE CONTACTOR CONTROLLED BY A TIME CLOCK. CONTACTOR SHALL BE WALL MOUNTED AND AS SPECIFIED ON SHEET E4.1. SEE LIGHTING CONTROL DIAGRAMS AND MASTER LIGHTING SWITCH BANK DETAIL ON SHEET E2.1. ©5 FIRE ALARM INTERFACE J-BOX FURNISHED AND INSTALLED BY LANDLORD FOR TENANT FIRE ALARM INTERFACE 9 CONNECTION. VERIFY LOCATION IN FIELD WITH LANDLORD PRIOR TO BID. CONTRACTOR SHALL COORDINATE ALL PROGRAMMING AND FINAL CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM AND SHALL CONTRACT WITH LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR. TENANT CONTRACTOR SHALL ONLY USE LANDLORD'S DE516NATEP FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE COMPATIBILITY WITH LANDLORD'S FIRE ALARM SYSTEM. t26 PROVIDE 1-1/4" EMT CONDUIT WITH PULL 5TRIN6 OVERHEAD FROM TELEPHONE BACKBOARD DOWN TO ITINUMMON RACK LOCATION. 02'X4' FIRE RATED PLYWOOD TELEPHONE BACKBOARD RECEIVED CITY OF TUKWILA FEB 2 6 -2015 AlftT gRAMSEE L4PERMIT AND pppROVAL J W N LY W W Z_ 0 Z W w ■ Q ASSOCIATES II, L.L.C. 281 Farmington Avenue Farmington, CT. 06032 SHEET NO. E1 i LP, 14 J W N ft1 O� w O Q O x w w O O N m LIGHTING CONTACTOR Cl- 4 POLE ELECTRICALLY HELD LI6HTIN6 CONTACTOR IN NEMA I ENCLOSURE, MANUAL OVERRIDE 120V COIL. MOUNT CONTACTOR IN TIMER SWITCH, TORK ACCESSIBLE LOCATION A5 NOTED #6506H OR EQUAL. ON THE DRAWIN65. / INTERIOR LIGHTING TIMECLOCK �7 N H SAP PROVIDE PILOT/ LIGHT SWITCH [0] Lu 000 d) LIGHTING a i CONTAGTOR5 L I IYC CONTACTOR L p w J_ N N COIL N J z GONTAGTOR GI o LOAD o O J J IL� IL z SO W d)l < J 0 J N a LI6HTIN6 CONTACTOR C2: 4 POLE ELECTRICALLY HELD LIGHTING CONTACTOR IN NEMA I ENCLOSURE, 120V COIL. MOUNT CONTACTOR IN ACCE55113LE LOCATION AS NOTED N H ON THE DRAWIN65. LP, 2 N H j�s6p PROVIDE PILOT / L16HT SWITCH -� 1 LINE w w of Uj H z LOAD GONTAGTOR G2 �j Jj 0 Q Q w a IL Q N N 1 LI6HTIN6 CONTACTOR 03: 4 POLE ELECTRICALLY HELD LI6HTIN6 CONTACTOR IN NEMA I ENCLOSURE, 120V COIL. MOUNT CONTACTOR IN ACCE551BLE LOCATION AS NOTED N ON THE DRAWIN65. 0_ J OINTERIOR LIGHTING TIMECLOGK LINE r-P PROVIDE PILOT LIGHT SWITCH GONTAGTOR L (y Q Q COIL N GONTAGTOR G3 0 z 3 I- z o T) IL LLI Ill O O N N LOAD I- O R LL w O N EXISTING xM CORRIDOR 0 O J J J J J J LINE CONTACTOR COIL N oO TOILET'ROOMO 004 O�oEM O EM O EM Ll 6 M4 M4 4M , 1 4 LP-6 Al A A A A A A A A AI —�— STOCK ROOM 003 I 3 CWr CM6 Al M4 M4 M4 I I � I I I 3 I F F F G G I Al I LP -IS ®a I 0 0 0 o A �ANUAL 7 I 1 VERRIDE IMER SWITCH I 5ALE5 FLOOR Al WIRE AHEAD OF I M4I CONTACTOR FOR OO2 N I I NL OPERATION NL LP-1 5 2 5 0 t_ [P-12 L I I I I LP-10 0T xM x1Al A A A A A � A A Z A Al Al O �0 'i �MR � MR EM— W-1 LI6HTIN6 PLAN SCALE: 1/4"= I'-O" LIGHTING GENERAL NOTES I. THE CONTRACTOR FOR THIS WORK 15 REQUIRED TO READ THE SPECIFIGATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND 15-RE5PON51BLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT 15 THI5 GONTRACTOR'5 RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTOR5 WITH A COMPLETE SET OF BID DOCUMENTS. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. 2. SEE ARCHITECTURAL REFLECTED GEILIN6 PLAN FOR EXACT LOCATION AND QUANTITY OF LIGHTING FIXTURES. EMEROENGY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODE5. ALL EMERGENGY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE (120/211 VOLT INPUT) WITH BATTERY BACKUP. 3. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 4. 'F' LI6HTIN6 FIXTURE 15 HUNG FROM 4 POINT5 IN THE GEILIN6 BY AIRCRAFT WIRE. GENERAL CONTRACTOR TO PROVIDE BLOGKIN6 AT ATTACHMENT POINTS. 5EE ARCHITECTURAL DRAWINGS FOR ADDITIONAL ATTACHMENT INFORMATION. 5. THE ABBREVIATION "AHJ" REPRE5ENT5 THE AUTHORITY HAVING JURISDICTION. TH15 SHALL INCLUDE BUT NOT BE LIMITED TO NATIONAL, STATE AND LOCAL GODE5. THE ULTIMATE AUTHORITY SHALL REST WITH THE LOCAL BUILDING OFFICIALS. 6. OWNER PROVIDED CUSTOM PENDANT LIGHTS, TYPE 'F', SHALL BE INSTALLED 50 THAT ALL VERTICAL 5EAM5 FACE TOWARDS THE REAR OF THE SALES, FLOOR. 1. MOUNT TYPE 'EM' LI6HTIN6 FIXTURES AT 12' AFF IN STOCK ROOM. 8. STOCKROOM OCCUPANCY 5EN5OR5 SHALL OPERATION IN CONJUNCTION WITH MANUAL 3-WAY SWITCHES FOR LIGHTING CONTROL. & POLE ELECTRICALLY HELD LOAD CONTACTOR 'CA'IN NEMA I ENCLOSURE, LP, I 120V COIL. MOUNT CONTACTOR IN LP. 3 AGCE551BLE LOCATION A5 NOTED LP, 5 ON THE DRAWI TYPICAL CONTROL LP WIRING: 3 #12 3/4" G LP, 4 GONTAGTOR. G4 LP II LP, IQ BRAND RIBBON L I &HT I NG n L 1 C HT I NG GONTR0L DPI AC-7RAMS SCALE: NONE LIGHTING CODED NOTES O CONNECT NIGHT 1_16HT/EMER6ENGY LIGHT FIXTURE5 TO CIRCUIT LP,14 . PROVIDE 56REW TYPE LOCK ON DEVICE AT THE BREAKER. O MASTER LIGHTING SWITGH BANK. SEE DETAIL ON THI5 SHEET. PROVIDE ADHESIVE LABELS TO 5WITGHES AS, INDICATED IN DETAIL. O HOMERUN THROUGH A 4-POLE CONTACTOR CONTROLLED BY A TIME SWITCH AND SWITCH "C'. TIME SWITCH AND CONTACTOR SHALL BE AS SPECIFIED ON SHEET E4.1 AND SHALL BE MOUNTED ADJACENT TO PANEL "LP". Q HOMERUN THROUGH A 4-POLE CONTACTOR CONTROLLED BY A TIME SWITCH AND SWITCH "Bu. CONTACTOR SHALL BE WALL MOUNTED AND AS SPECIFIED ON SHEET E4.1. SEE MASTER LI6HTIN6 SWITCH BANK DETAIL ON THIS SHEET. OS, HOMERUN THROUGH A 4-POLE CONTACTOR CONTROLLED BY A TIME SWITCH AND SWITGH "A". CONTACTOR SHALL BE WALL MOUNTED AND A5 SPECIFIED ON SHEET E4.1. SEE MASTER LIGHTING SWITCH BANK DETAIL ON THIS SHEET. O6 PROVIDE JUNCTION BOX AND TO66LE DISCONNECT SWITCH IN CONGEALED LOCATION FOR STOREFRONT 120V SIGN. COORDINATE EXACT LOCATION WITH ARCHITECTURAL PLANS. Q CONNECT NIGHT LITE/EMER&ENGY LIGHT FIXTURES TO CIRCUIT LPb AHEAD OF THE LOCAL 5WITGHIN6. O REUSE THE EXISTING BATHROOM LI6HTIN6 FIXTURE. PROVIDE NEW OCCUPANCY 5EN50R SWITCH AND WIRING. L I C HTI NC FIXTURE SCHEDULE FIXTURE WATT5 5YMB0L DE5GRIPTION FIXTURE WATT5 5YMWL DE5GRIPTION TYPE TYPE WALL MOUNT RECESSED L.E.D. ADJUSTABLE WALLWA5H. RECESSED GEILIN6 MOUNT EMER6ENGY L16HT. A 40 �'°' AMERLUX 1-I61-ITIN6 'MINI GAVALETTO 4X4" MR FINISH: WHITE. #MGAV-40-LED-E-WT-120-WW-4000 ENCORE LI6HTIN6 #EMR-I2--15 234 GEILIN6 MOUNT REGE55ED L.E.D. ADJUSTABLE SINGLE LAMP 4' FLUORESCENT STRIP LIGHT, T-5 Al 40 C3 Al WALLWASH. AMERLUX LI6HTIN6 "MINI GAVALETTO 4X4' M4 25 Q WITH PLASTIC 61UARD. #MGAV-40-LED-E-WT-120-1414-4000 LITHONIA LI6HTIN6 #2-I-32-MV0LT-6EBIOI5-WZ48 B SINGLE LAMP REGE55ED L.E.D. ACCENT LIGHT. B 2& AMERLUX LIGHTING "GYLINDRIX 11 6EN 2" M32 56 NOT USED #G262R-I 2&-LED-E-WT-120-FL-WT-4000 C 56 TWO LAMP REGE55ED L.E.D. ACCENT LIGHT. AMERLUX LIGHTING 'GYLINDRIX II 6EN 2" 5-5OX 516N BOX #G262R 225-LED-E-WT-120-FL-FL-WT-4000 s-sox D 38 Q NOT USED X 3x NOT USED REGE55ED WALL MOUNTED EDGELIT EXIT 516N. G.G. TO DI 35 a of NOT USED XI 3 VERIFY MOUNTING REQ'D d CHEVRONS DIRECTION. WIRE xl TO LOCAL LI6HTIN6 CIRCUIT AHEAD OF 5WITGHIN6. EXITRONIX NYg00 SERIES #NYg02-R-WB-RC-?-WH-GI. D N/A NOT USED X2 3 0112 NOT USED EM 10 EM WALL MOUNTED DUAL HEAD EMERGENCY LIGHT. WIRE TO LOCAL LI6HTIN6 CIRCUIT AHEAD OF LOCAL 5WITGHIN6. XM 3.6 xM WALL MOUNTED COMBINATION EXITLI6HT/ EMERGENCY LIGHT EXITRONIX VEXG-8 SERIES, #VEXG-8-5-WB-WH 2. CONTEGH LIGHTING #EL2HA5W-P PROVIDE CHEVRON WHERE INDICATED ON FLOOR PLAN CU5TOM PENDANT FIXTURE TO BE SULPLIED BY LE60 F 112 (a AND INSTALLED BY GENERAL CONTRACTOR. I6 x 7 WATT COMPACT FLUORESCENT GLOBE TYPE LAMPS. SEE LI61-ITIN6 GENERAL NOTE #4. NOTE: CONTRACTOR SHALL EXPECT TO RECEIVE A SPARE LAMP KIT FROM THE OWNER. THIS KIT WILL INCLUDE A MINIMUM OF SIX (6) -7 WATT COMPACT FLUORESCENT LAMPS FOR THE "F" FIXTURES. THESE LAMP SHALL BE TURNED OVER TO THE STORE MANAGER UPON COMPLETION OF THE PROJECT. 9 6 B TIMEGLOGK STOREFRONT SALES AREA SALES AREA STOCK -ROOM OVERRIDE WINDOW DISPLAY WALLS PENDANT LIGHTS LI61-ITING 516NA6E GENERAL LI6HTIN6 0 � 0 BACK OF HOUSE LI6HTIN6 MASTER L I C HT I N 6 SP11 TGH BANK SCALE: NONE RE G00P, ®CE Cod AppFtOdE Mp,R 16 2p15 -�u�vvila CAI o G �`v,s`oN FIELD \/ERIFY ALL GONDITION5 DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL V151T THE 51TE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITION5. THI5 CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE DESIGNER, ENGINEER OR OWNER PRIOR TO BIDDIN6 FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DE516N AND INCLUDE IN HI5 BID ALL G05T5 TO MEET THE DE516N INTENT. CLARIFICATIONS MADE BY THE DESIGNER, ENGINEER OR OWNER AFTER BIDDIN6 WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING GONTRAGTOR5 SHALL HAVE A WORKING KNOWLEDGE OF LOCAL GODE5 AND ORDINANCES AND SHALL INCLUDE IN THEIR 13I05 THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODE5, THE PLANS AND 5PECIFICATION5 NOT WITHSTANDING. THE CONTRACTOR 5HALL ALERT DESIGNER, ENGINEER OR OWNER OF ANY APPARENT 015GREPANGIES BETWEEN GOVERNING CODES AND DE516N INTENT. REFER TO ARCHITECTURAL DRAWIN65 FOR ADDITIONAL INFORMATION. THERE WILL BE NO CONSIDERATION FOR CHANGE ORDERS FOR INFORMATION FOUND ON ARCHITECTURAL DRAWINGS. RECEIVED CITY OF TUKWILA FEB 2 6 2015 P ,M , 1T AND OVAL IRED ted on c cled R N csi m w Q l O 1 c� LU z Z w w w Q (Y v w O O � � EL 3�a LLJ Wm0 9x w % W H Q 0 Ln mrym V 0 ryryN �pMEs < 0`2�'oF WASGO N (L. N ^^'' w 027657 �w z /STERN ��''�.► 0 �AL E� z w U. ASSOCIATES II, L.L.C. 281 Farmington Avenue Farmington, CT. 06032 SHEET NO. E2.1 ELECTRICAL SERVICE ANALYSIS SERVICE VOLTAGE 480/277 OCCUPANCY RETAIL LOAD DESCRIPTION DIVERSITY WATTS FT CONNECTED LOAD (KVA) DEMAND LOAD (KVA) GENERAL LIGHTING 100% 5.3 5.3 TRACK LIGHTING 150VA12- 100% 150 0 0 0.0 RECEPTACLES NEC 220 10KVA-100%; BAL-50% 1 13.4 11.7 SHOW WINDOW LIGHTING 200VA/LF 100% 200 19 0.168 3.8 HEATING* VAVs 100% 13.0 13.0 COOLING* 100% 0.0 0.0 MOTORS EF 100% 0.1 0.1 25% OF LARGEST MOTOR 25% 0.0 0.0 WATER HEATER 100% 1.5 1.5 MISC. KITCHEN EQ. 100% 1.5 1.5 TOTALS: TOTAL CALCULATED LOAD (KVA): 35.0 36.9 TOTAL DEMAND AMPS @ 480V 42.1 44.4 *use greatest of two loads Panel Designation: LP (Existing) Location: Southcenter, WA Amperage / Mains: 150 MCB AIC: V.I.F. Voltage / Phase 208/120V, 3 Feeder: 40110,1#6G, 2"C Mounting SURFACE Computer/TVSS: No CIRCUIT BREAKER LTG REC MISC MISC REC LTG CIRCUIT BREAKER Auo on: oc : nen nCCrP=Tlnu KVA KVA KVA I A I R I C I KVA KVA KVA I nAn nFSCRIPTIAN AMP P01 FS 1 20 1 Receptacles - Showcase 0.2 0.7 1.0 0.2 Lighting -Window 20 1 2 3 20 1 Receptacles -Showcase 0.1 0.7 1.1 0.2 Lighting - Front 20 1 4 5 20 1 Receptacles - Showcase 0.1 1.1 2.0 0.8 Lighting - Side 20* 1 6 7 20 1 Receptacles - Showcase 0.1 0.9 1.5p 0.4 Lighting - Pendant 20 1 8 9 20 1 Receptacles - Pick a Brick Wall 0.2 0.9 0.7 Lighting - Sales Floor 20 1 10 11 20 1 Receptacles - Pick a Brick Wall 0.1 0.3 0.2 Lighting - Pick -a -Brick 20 1 12 13 20 1 Receptacles - Cash Register IG 1.4 --2.2 0.1 0.7 Ltg - Stckrm/NUExits/Emg/EF 20* 1 14 15 20 1 Receptacles - StoreFront 0.9 2.1 1.2 Spare 20 1 16 17 20 1 Receptacles - Cashwrap 0.7 0.7 0.0 Lighting - Sign 20 1 18 19 601 2 VAV-1 5.0 :5.0 0.0 Spare 20 1 20 21 60 5.0 15.2 0.2 Telephone Backboard 20 1122 23 20 1 Electric Water Heater 1.5 2.5 1.0 Receptacles - IT Rack 30 1 24 25 20 1 Spare 0.7 0.7 Receptacles - Floor 20 1 26 27 20 1 Receptacles - Telephone Rack 0.8 2.3 1.5 VAV-2 20 228 29 20 1 Spare 1.5 1.5 20 30 31 20 1 Receptacles - Fridge 0.5 1.6 1.1 Receptacles - Cashwrap 20 1 32 33 20 1 Receptacle - WiFi 0.2 1.2 1.0 Receptacle - Microwave 20 1 34 35 20 1 Receptacles - Office 1.1 1.6 0.2 0.4 Receptacle- Toilet/Water Clr 20 1 36 37 20 1 Receptacles - Office 0.4 0.4 Spare 20 138 20 1 Time/attendance Device 0.2 0.9 0.7 Receptacles - Floor 20 140 E 20 1 ISpare 0.0 0.3 0.3 Recept - Stock Rm/Buaer 20 1 42 Connected Load (KVA): Computed Load (KVA): Total Connected Load (KVA): Total Computed Load (KVA): 1 12.41 UAI 9 01 0.9 1 9.1 12.01 1 1 1 4.3 1 4.3 4.4 1.7 1 9.1 1 9.6 1 1 1 1 3.4 1 4.3 5.5 35.0 Computed Load (A): 92 33.0 125% of Computed Load 115 Poles Used: 42 *Provide locking CB PROVIDE RELAY TO TURN OFF SOUND SYSTEM WIRIN6 CONNECTION POINT PROVIDED BY LANDLORD'S ELECTRICAL CONTRACTOR AT TENANT'S EXPENSE. FINAL CONNECTIONS MADE BY LANDLORDS ELECTRICAL CONTRACTOR AT TENANT'S EXPENSE LANDLORDS EXISTING FIRE ALARM CONTROL PANEL F 2#16 TWISTED SHIELDED PAIR IN 3/4" EMT OR AS OTHERWISE REQUIRED BY MANUFACTURER PROVIDED BY TENANT CONTRACTOR 2#16 AW6 TP 4 2#14 AW6 T5P IN 3/4" EMT OR AS OTHERWISE REQUIRED BY MANUFACTURER (TYPICAL) PROVIDED BY TENANT CONTRACTOR 15 75 -55 -15 END OF LINE RE515TOR (TYPICAL) TENANT _ SPACE --------------- - -- LANDLORD'S - WIRING TO LANDLORD'S SPACE EXISTING FIRE ALARM CONTROL PANEL PROVIDED BY LANDLORD'S DESIGNATED GONTRAGTOR AT TENANT'S EXPENSE. FIRE ALARM RISER DIAGRAM SCALE: NONE NOTE: I. VERIFY COUNTS AND LOCATIONS WITH ELECTRICAL FLOOR PLANS. 2. ALL WIRING SHALL BE PER MANUFACTURERS REQUIREMENTS. 3. ALL FIRE ALARM WIRING SHALL BE IN EMT CONDUIT. EST #5q2 120Vac, COMBINATION HORN/STROBE, 24VdC TRANSFORMER �� EDWARDS SYSTEMS TEGHNOLOGY (EST) #6536-G5 OR ACCEPTABLE n n EQUIVALENT. (2) #14, 1/2" G ! 1 1 PC - GORE) SWITCH EST #6537 GALL FOR ACID SYSTEM SCALE: NONE THREE PHASE TRANSFORMER XFMR NUMBER 480V. PRIMARY (N 3PH.,3W. 120/208V. SECONDARY CO)3PH.,4W. GROUNDING GONNEGTION KVA RATING XFMR EFF. O.G. PROT. C' RGUIT SIZE O.G. PROT. GFRGUIT 51ZE EX-45 80A EXISTING 150A EX15TIN67 I#6- 45 220°C NOTES' I. EX-45 TRANSFORMER 15 EXISTING. TRANSFORMER EFFICIENCY RATINGAN5ULATION CLASS OBTAINED FROM EXISTING FIELD DATA. 2. 6ROUNDIN6 OF SEPARATELY DERIVED SYSTEMS SHALL COMPLY WITH NEC, ARTICLE 250.30. PROVIDE GROUNDING ELECTRODE CONDUCTOR CONNECTIONS. CONNECT TO THE NEAREST GROUNDED STEEL COLUMN OR CODE APPROVED ELECTRODE. LANDLORD'S SPACE LANDLORD'S GABLE MAY Al CONTRACTOR SHALL PROVIDE TEL. CONDUIT TO LANDLORDS EXISTING GABLE TRAY IN CORRIDOR. COORDINATE FINAL LOCATION OF GABLE TRAY WITH LANDLORD (VERIFY IF CONDUIT 15 EXISTING PRIOR TO BID) TENANT SPACE 1-1/2' CONDUIT WITH TELEPHONE SERVICE GABLE u u NEW TELEPHONE BACKBOARD 1-1/4' CONDUIT WITH PULL 5TRING IT RACK 6ROUND (TYP) TELEPHONE S I N6L E LINE CN ASIRAM SCALE: NONE LANDLORD'S SPACE TO UTILITY '10qOANOTE q LANDLORD'S MAIN SERVICE ELECTRICAL DISTRIBUTION SERVICE EQUIPMENT "SWITCHBOARD IG" WITH EXISTING UTILITY SERVICE BREAKER. COORDINATE ALL SHUTDOWNS WITH LANDLORD. 5EE NOTE & TENANT SPACE VAAV 2 VAAVV-I 3#12 d I#12 6, 3/4" C PANEL EX-45 'LP' EXISTING 205/120V PANELBOA RD 'LP' IOOA, 600V FUSED SERVICE DISCONNECT SWITCH EXISTING 45KVA TRANSFORMER TO REMAIN ELECTRICAL SIN6LE LINE PIA6RAM -NEW 5AALE: NONE POWER RISER DIAGRAM GENERAL NOTES I. HVAG CIRCUIT BREAKERS SHALL BE "HAGR" TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.G. 2. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT A.I.G. RATING OF LANDLORDS DISTRIBUTION EQUIPMENT, FURNI5H AND INSTALL TENANTS SYSTEM TO MATCH. 3. ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO ±10% BETWEEN PHASES: A/B, B/G, AND A/C RE&ARDLE55 OF CIRCUITING INDICATED. 4. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.G. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. REPORT EX15TINO CONDITIONS THAT DO NOT COMPLY WITH N.E.G. FOR PROPER FIELD CLEARANCES. 5. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. 6. CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE. -7. CONTRACTOR SHALL ENSURE EXI5TIN6 GROUND TO BUILDING STEEL IN TENANT'S SPACE AS PER LANDLORD'S CRITERIA AND N.E.G. 8. CONTRACTOR SHALL PROVIDE AN IDENTIFICATION NAMEPLATE ON TENANT'S MAIN DISCONNECT SWITCH IN LANDLORDS SWITCHBOARD. NAMEPLATES SHALL BE ONE-E16HT (I/M THICK PLASTIC, BLACK ON WHITE WITH ETCHED LETTERS. MINIMUM 51ZE SHALL BE ONE INCH (I") WITH TENANT'S NAME AND ADDRESS ENGRAVED ON SUCH, PERMANENTLY AFFIXED. 9. LANDLORD PROVIDED MASTER METERING EQUIPMENT IN LANDLORD'S ELECTRICAL ROOM. LANDLORD -OWNED NETWORK METERING SYSTEM SHALL METER TENANT POWER CONSUMPTION. 10. PRIOR TO BID, CONTRACTOR SHALL COORDINATE AND CONFIRM THE FOLLOWING WITH LANDLORD'S REPRESENTATIVE: 10.1. WORK BY LANDLORD AT LANDLORD'S EXPENSE 10.2. WORK BY LANDLORD AT TENANT'S EXPENSE 10.3. WORK BY TENANT AT LANDLORD'S EXPENSE 10.4. WORK BY TENANT AT TENANT'S EXPENSE LANDLORDS SPACE EXISTING FEEDERS TO REMAIN TO UTILITY LANDLORD'S MAIN SERVICE ELECTRICAL DISTRIBUTION SERVICE EQUIPMENT WITH EXISTING TENANT SERVICE BREAKER. COORDINATE ALL SHUTDOWNS WITH LANDLORD. LABEL BREAKER WITH TENANT NAME AND ADDRESS. TENANT SPACE E Gp � �Q VAV-I 00 t' 1 Zp�S ot EXISTING---'CA p1 TO -REMAIN P� I I I I IOOA, 600V FUSED SERVICE DISCONNECT SWITCH TO REMAIN ELECTRICAL SIN6LE LIN SCALE: NONE EXISTING 208/120V PANELBOARD TO -REMAIN RECEIVED CITY OF TUKWILA ? PANEL FEB 2 6 2015 - •LP' -3ERMiT CENTER EXISTING 45KVA TRANSFORMER TO REMAIN ` PP i '4 DA AM1. m m w QI p ry Z o Q m m p W O z z � W W W w O < p K � O H z CL OL W�a jLU 0 0 CS H 11.1 r Q 0 m ry ry W 0 Cl � W Q � Q � w Tin W � W 0 04 J Q N W W z Z LU N� I..L� ASSOCIATES II, L.L.C. 281 Farmington Avenue Farmington, CT. 06032 SHEET NO on .r 2012 Washington State Energy Code Compliance Forms for including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Info Project Address Southcenter Mail Space #1450 Date 1/22/2015 Compliance Seattle, Washington For Building Department Use forms do not require a password to Applicant Name: LEGO use. Instructional and calculating cells Applicant Address: Applicant Phone: are wite- Project Description 1[3Nevv Building 13Addition ® Alteration ® Plans Included Lighting Compliance Path `Lighting Power Density Calculations 0 Total Building Performance (If Total Building Performance then only LGT-CHKis Lighting Power Allowance 0 Building Area Method Space -By -Space Method Method Selection required to enable LPA farms Interior Lighting System Retail sales floor and display lighting utilizing L.E.D. fixtures and decorative fluorescent Description fixtures. Stockroom and toilet room lighting utilizing fluorescent fixtures. Sales floor and display lighting controlled via programmable timeclock/contactor With manual on/off and timer switch bypass. Briefly describe lighting system type and features. Stockroom and toilet room lighting control via manual/occupancy sensor controls. Additions and Change of Space Use (C101.4.3 & C101.4.4) ® Addition area or Change of Space Use area complies with all applicable provisions as stand alone project 0 Addition area is combined with existing building fighting systems to demonstrate compliance with all applicable provisions per C101.4.3 Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) ® 60% or more of luminaires in space replaced Provide Building Area Method (LTG-INT-BCD) or Space -By -Space Method (LTG-INT SPACE) Compliance Form. Document maximum allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Retrofit and non -retrofit spaces shall be documented separately using multiple forms. 0 Less than 60% of luminaires in space replaced Provide a separate Space -By -Space Method (LTG-INT-SPACE) Compliance Form for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage table. 0 Lamp and/or ballast replacement within existing luminaires only -existing total interior building wattage not increased Q New wiring installed to serve added fixtures andlor fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405 2.3), and commissioning of lighting controls per C405.13 0 Newor moved fighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. 13Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. 0 No changes are being made to the interior lighting and space use not changed. Lighting, Motor, and Transformer Permit Documents Checklist LTG-CHK' 2012 Washington State Energy Code Compliance Forms for Commercial Buildingsincluding R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address Southcenter Mail Space #1450 Date 1/22/2015 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Applicability Location in Building Department (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes LIGHTING CONTROLS (Section C405.2) C405.2.1.1 Manual interior Indicate on plans the manual control type & locations served; E2.1, Rm. 004 Indicate of plans the 50% lighting load reduction method Exception #3 Yea C4U5.2.1.2 lighting controls provided or identify exception faker Indicate lighting system automatic shut-off capability - identify E2.1, Sales F1002, lighting zone areas served on plans; timeswiich of override switches on plans and the areas locainclude __ Sw: Rm. 004; ryes E2.1, Sales Yes C405.2.2.1 Automatic time switch controls and override switching served, include area sq. ft ; served, Ff 002 Indicate locations where automatic shutoff is provided by other E2.1, 003 & 004 methods (occupancy sensor, daylight controls, etc Yes C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors E2.1, 003 & 004 Daylight zones - Indicate vertical fenestration primary and secondary daylight NA C40522.3 Vertical fenestration zone areas on plans, include sq. ft; and skylights indicate skylight daylight zone areas on plans, include sq. it Daylight zone indicate on plans the locations served by daylight zone controls; RA C405.2.2:3.2 controls Indicate in plans the lighting load reduction (dimming) method - stepped or continuous dimming Yes C405.2.3 Specific application lighting controls - Indicate on plans the locations served by specific application E2.1, 002 General lighting controls Indicate lighting control method for display and accent lighting, Manual & Time C405.2.3 - Display and accent and display case lighting; Switch Indicate these fixtures are controlled independently from both Yes items 1&2 lighting general area lighting and other lighting applications within the E2.1 same space C405.2.3 - Hotel/motel guest Provide a lighting control device at each guest room entry for all > n► Item 3 rooms permanently installed fixtures in guest room; Indicated whether lighting control is manual or automatic C405.2.3 - Supplemental task Provide automatic shut-off vacancy controls for supplemental tm Item 4 lighting task lighting, including under -shelf or under -cabinet lighting Identify eligible non -visual applications and method of lighting C405.2.3 - Lighting for non- control;ail► Indicate these fixtures are controlled independently from both Rem 5 visual applications general area lighting and other lighting applications within the same space Indicate lighting control method for lighting equipment for sale C405.2.3 - Lighting equipment or demonstration; Indicate these fixtures are controlled independently from both rm Rem 6 for sale or demonstration general area lighting and other lighting applications within the same space 9 egress lighting power density is greater than 0.05WIfe, C405.2.3 - Means of egress indicate method of automatic shut-off during unoccupied NA Rem 7 lighting cods; Identify on plans the egress fixtures that function as both normal and emergency means of egress illumination C405.10 Cooler and freezer Provide vacancy device or timer to turn off fixtures within 15 NA C405.11 lighting minutes ofunoccupancy for cooler and freezer lighting fixtures with lamp efficacy less than 40 lumens per waft Exterior lighting Indicate on exterior lighting plans the automatic lighting control NA C405.2.4 controls method and locations served Exterior building Provide motion sensor Controls for building grounds fixtures NA C405.6.1 grounds lighting rated at greater than 100 watts with lamp efficacy less than 60 controls lumens, or identify exception taken Identify applicable commissioning documentation requirements Exception Taken per Section C408 or eligibility for exception: Provide written procedures for functional testing of all automatic NIA Yes C408.3 Lighting system functional testing controls and describe the expected system response; Identify in construction documents the party responsible for NIA functional testing of automatic lighting controls INTERIOR LIGHTING POWER & EFFICACY Sections C405.5 C405.10, C405.11 Provide fixture schedule with fixture types, lamps, ballasts, and rated watts per fixture; T 2012 Washington State Energy Code Compliance Forms for Project Address' SouthcenterMail Space #1450 Date 1/22/2015 Lighting Alterations, Renovations & Building Additions For Building Department Use 0 Less than 60% 060% or more 0 Stand alone 0 Addition fixtures replaced fixtures bldg. addition combined Notes. a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. b. For retrofits and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting table. If a builidng addition will comply as combined mith the overall existing builidng, include all applicable existing Space Types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. ff less than 60% of existing fixtures mill be replaced, provide total existing lighting wettage (prior to retrofit) in the space provided in the Maximum Allowed Lighting table. Maximum Allowed Lighting Wattage Location (plan room #) Space Type* Watts per fe Area in fly (watts/f? x area) E2.1, Rm. 002 Retail: Sales area 1.68 1275 2142 E2.1, Rm. 003 Storage 0.63 548 345 E2.1, Rm. 004 Restroom 0.98 59 58 um n r ng a9 9 n , x77 e . DleplxryAllowarlcefrom ITGaNT-0ISPLi41f 1000 ' Select Table C405.5.2(2) category from drop down menu. ** For atriums, indicate height Allowed wattage for first 40 feet is 0.03 W!ft ht., above 40 feet is 0.02 Wlf . lit Proposed Lighting Wattage Area Allowed Watts Total 1882 3545 Location (plan # room #) Fixture Description- Number of Fixtures Watts/ Fixture Watts Proposed E2.1, Entry 001 Fixture Type B: LED recessed 1 28 28 E2.1, Sales Ft. 002 Fixture Type B: LED recessed 5 28 140 E2.1, Sales FI.002 Fixture Type C: LED recessed 16 56 896 E2.1, Sales FI.002 Fixture Type F: CFL Decorative Pendant; 7W CFL 4 112 448 E2.1, Sick Rm 003 Fixture Type M4: Fluorescent Strip; T 8, Electronic Ballast 12 56 672 E2.1, Toilet 084 Fixture Existing; 1'x1' recessed fluorescent 1 26 26 Reta)i Display Lighting from LTG-INT-DISPLAY,: „ 1000 Total Proposed Watts may not exceed Total Allowed Watts for Interior lighting Total Proposed Waq 3210 *`* Include existing to remain lighting fixtures and exemptlighting equipment pernotes below! Notes: 1. Include ALL proposed lighting fixtures. 2. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballastinfo►madon. 3. For proposed WattslFixtue, use manufacturer's listed maximum input weftage of the fixture (not simply the lamp wettage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wettage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices of the transformer. For low voltage track lighting list the transform errated wattage. 4. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 5. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description. 6. If #NA appears in Retail Displaycells, information on LTG4NT-DISPLAY is incomplete. Interior Lighting Power Allowance COMPLIES Lighting, Motor, and Transformer Permit Documents Checklist LTG-CHK1 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address SouthcenterMail Space #1450 Date 1/22/203.5 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commensal Provisions. Applicability Location in Building Department (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes Identify spaces eligible for lighting power exemption on plans C405.5.1.1 connected and in compliance forms; E2.1, Rm. 002 Yes C405.5.1.2 -Total C405.5.1.3 interior lighting power Identify lighting equipment eligible for exemption in fixture E2.1, Type EM C405.5.1.4 schedule and in compliance forms; Indicate that exempt lighting equipment is in addition to general E2.1, Sign Light area lighting and is controlled independently Yea C405.4 Exit signs Provide exit sign types and rated wafts per fixture in fixture LED Type: 3w schedule (maximum 5 watts per future) C405.10 Cooler and freezer For lighting in walk-in coolers and freezers, and refrigerated N►► C405.11 lighting warehouse coolers and freezers, provide rated lamp efficacy (in lumens per watt) in fixture schedule Lighting PowerCalculation -Indicate compliance path taken Building Area Complete required compliance forms- proposed wattage per No C405.5.2 Method building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans Complete required compliance forms- total proposed wattage Yes C405.5.2 Space -By -Space does not exceed maximum allowed wattage. Identify locations of E2.1-Ltg Plan Method space types on plans, including retail display areas as E3.2-Forms applicable EXTERIOR LIGHTING POWER & EFFICACY Section C405.6 Provide fixture schedule with fixture types, lamps, ballasts, and Total connected rated watts per fixture; -- Identify exterior applications eligible for lighting power - NA C405.6.2 exterior lighting exemption on plans and in compliance forms; power Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting Nor Table C405.6.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ Exterior building For building grounds fixtures rated at greater than 100 wafts, IRA C405.6.1 grounds lighting provide rated lamp efficacy (in lumens per watt) in fixture schedule Exterior lighting Complete required compliance forth - proposed wattage for NA C405.6.2 power calculations exterior lighting plus base site allowed does not exceed maximum allowed MOTORS & TRANSFORMERS (Sections C405.8, C405.9) tor► C405.8 Electric Motors For motors not part of an HVAC system, provide electric motor schedule on electrical plans with hp, rpm, and rated efficiency Yes C405.9 Transformers Provide distribution transformer schedule on electrical plans E3.1, Existing with transformer size and efficiency Transformer no Is SeleG[eu Y01 "No" selected for C405.5.2 Building Area Method because "Yes" selected for C405.5.2 Space -By -Space Method. State over 61Hl Project Info Project Address Southcenter Mail Space #1450 Date 1/22/2015 Seattle, Washington For Building Department Use Applicant Name: LEGO Maximum Allowed Display Lighting Wattage (plan # room #) Retail Display Area Type* o Watts per if ** rossnenLocation Area in if o e (wattsfif x area) E2.1, Rm. 002 Retail 1: All unclassified retail display 0.60 899 539 * Only retail sales areas that meet the requirements defined in Table Area Area Watts C405.5.2(2) footnote A maybe entered here. Select retail sales areas form drop Total 899 539 down menu. ** Wattages per Table C405.5.2(2) footnote A. Display Lighting Base Allowan S o o ++ Display light allowance per footnote A calculation. ++ Total Display Allowan 1039 Proposed Display Lighting Wattage il r)niv eannornfo/v ennfm►►crl rlicniw 6wh,rec indnnenrrnnf of nn-I - minhHnn her Tehin CAnt. , 0/01 f fnnf A m „ ha h...r. Display Area* Location (plan # room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Retail 1 E2.1, Rm. 002 Fixture Type A: LED recessed 16 40 640 Retail 1 E2.1, Rm. 002 Fixture Type Al: LED recessed 9 40 360 setect►etau sates disptayarea from crop down menu. DISPLAY WATTAGE ALLOWED - AS PROPOSED Total Proposed Watts 1000 Proposed Display Retail 1 Retail 2 Retail 3 Retail 4 Lighting Totals i000 Notes: 1. For proposed Display Fixture Description, indicate fixture type, lamp type (e.g. T-8), numberof lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast Fnthanation. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wettage. 3. List all display fixtures. �oE GQ P►QP� 6 Zp15 Mai 1 �ti {�U I \;\ON G OONc' 4 RECEIVED CITY OF TUKWILA FEB 2 6 2015 PERMIT CENTER SEPARATE PERMIT AND APPROVAL 'Jnon�l�ecucled EL d m W W W W O Z I3NEL oC jm OW tx W l_n v • � 43 LU Qq 0 d) 0 N hl N O Z H W COL L1. 0 4.4 J W N W W Z Z W I.L • 1.L ASSOCIATES II, L.L.C. 281 Farmington Avenue Farmington, CT. 06032 SHEET NO. T" ^ E32 ELECTRICAL SPECIFICATIONS GENERAL CONDITIONS: A. THE REQUIREMENTS ASSET FORTH UNDER GENERAL CONDITIONS, INSTRUCTIONS TO BIDDERS AND GENERAL REQUIREMENTS ARE A PART OF TH15 CONTRACT. B. B105 SHALL BE BASED ON A COMPLETE/FULL SET OF ORAWIN65. G. CONTRACTOR MUST READ THE ENTIRE SPECIFICATIONS GOVERIN& OTHER BRANCHES OF WORK AND 15 RESPONSIBLE FOR COORDINATION OF THE WORK WITH WORK PERFORMED BY OTHER TRADES. SCOPE OF WORK: A. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING. B105 SHALL SERVE A5 EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. ALL REQUIREMENTS INGLUDIN6 MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWIN695 AND SPECIFICATIONS ARE TO BE OBTAINED BY ELECTRICAL CONTRACTOR PRIOR TO AND INCLUDED IN BID PRICE. FIELD VERIFY ALL EXISTING ELECTRICAL AND TELEPHONE EQUIPMENT, LOCATIONS, CONDITIONS ETC. FAILURE TO VI51T THE SITE SHALL NOT RELIEVE THE CONTRACTOR FROM ANY RESPONSIBILITY IN THE PERFORMANCE OF THE ELECTRICAL WORK. B. FURNISH ALL LABOR, MATERIALS, TE5TIN6, EQUIPMENT, INCIDENTALS AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. I. MATERIALS, PRODUCTS AND EQUIPMENT, INGLUDIN6 ALL COMPONENTS THEREOF, SHALL BE NEW AND AS SUCH APPEAR ON THE UNDERWRITERS LABORATORIES L15T OF APPROVED ITEMS AND SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES, WHICHEVER ARE MORE STRINGENT. C. THE WORK 15 TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC, AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES. D. INCLUDE ANY LABOR AND MATERIALS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO PROVIDE A COMPLETE AND FULLY OPERATIVE ELECTRICAL SYSTEMS. PERMITS: A. SECURE AND PAY FOR ALL REQUIRED PERMITS, FEES, A55E55MENTS AND INSPECTION CERTIFICATES THAT RELATE TO THE ELECTRICAL CONTRACT. B. FURNISH APPROVED CERTIFICATE OF FINAL INSPECTION, AND TURN OVER TO OWNER AT COMPLETION OF PROJECT. DRAWINGS AND 5PECIFICATION5: A. THI5 ELECTRICAL PLANS ARE DIA&RAMMATIG, NOT SHOWING EVERY ITEM IN EXACT LOCATION OR DETAIL. MEASUREMENTS AND LOCATIONS MUST BE FIELD VERIFIED AND COORDINATED WITH ARCHITECTURAL, PLUMBING, HVAC, FIRE PROTECTION, FIRE ALARM, STRUCTURAL, AND OTHER BUILDING ORAWIN65. SHOP ORAWIN&5: A. 54JBMIT FIVE COPIES OF MATERIAL L15T5 AND SHOP DIRAWIN&5 FOR MAJOR EQUIPMENT TO THE OWNER'S CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS EARLY ENOUGH IN PROJECT TO ALLOW AMPLE TIME FOR OWNER'S -REVIEW WITHOUT CAUSIN& TIME DELAYS OR CONFLICTS IN THE JOB PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND THE MANUFACTURERS LISTED ON THE DRAWINGS AND SHALL BEAR THE STAMP OF THE CONTRACTOR 51­1014IN6 THAT HE HAS REVIEWED AND APPROVED THEM AND THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWIN&5. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR'REJEGTION WITHOUT -REVIEW BY THE OWNER. B. WHERE TRADE NAMES, BRANDS OF MANUFACTURERS OF EQUIPMENT OR MATERIALS ARE SHOWN ON THE DRAWIN6,5 OR SPECIFICATIONS THE EXACT EQUIPMENT SHALL BE USED ON THE PROJECT. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND -REPLACEMENT AT THE -REQUEST OF THE OWNER'S CONSTRUCTION MANAGER (AT THE ELECTRICAL CONTRACTORS EXPENSE). C. IN ORDER TO BE AUTHORIZED FOR U51N& EQUIVALENT / "OR EQUAL" EQUIPMENT THE CONTRACTOR MUST FIRST GET APPROVAL FROM THE GENERAL CONTRACTOR STATING IN WRITING THE EXACT REA50N WHY THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED. THEN THE GENERAL CONTRACTOR MUST FORWARD THE REA50N AND A GUT OF THE SUBSTITUTED EQUIPMENT TO THE ENGINEER AND THE OWNER FOR APPROVAL. D. IF THE CONTRACTOR WISHES TO SUBSTITUTE ANY SPECIFIED ITEMS A WRITTEN REQUEST SHALL BE SUBMITTED TO THE CONSTRUCTION MANAGER 5TATIN6 WHY THE SPECIFIED ITEM SHOULD BE REPLACED. SHOP DRAWINGS OF THE "OR EQUAL" ITEM AND THE WRITTEN SUBSTITUTE -REQUEST MUST BE SUBMITTED TO THE ENGINEER AND OWNER FOR APPROVAL PRIOR TO THE EQUIVALENT ITEM BEING PURCHASED AND DELIVERED TO THE SITE. CONDUITS: A. CONDUIT SHALL BE STANDARD STEEL -RI610, IMG OR EMT (THIN WALL) AC( OROIN6 TO LOCAL CODE AND LANDLORD REQUIREMENTS. CONDUIT SHALL BE CONGEALED IN FINISHED AREAS, EXCEPT A5 OTHERWISE APPROVED BY DE516NER. EMT CONNECTIONS SHALL BE COMPRESSION OR SET SCREW TYPE. B. FLEXIBLE CONDUIT OR TYPE MG GABLE SHALL BE USED FOR FINAL CONNECTIONS TO L16HT FIXTURES, MOTORS AND VIBRATING EQUIPMENT ONLY; AND WHERE 50 USED TO BE 6ROUNDEO WITH A SEPARATE FULL SIZED GREEN GROUNDING CONDUCTOR. FINAL TYPE MG/FLEX CONNECTIONS SHALL BE LIMITED TO 4'-0" IN LENGTH. (ARRANGE CIRCUITS 50 AS TO AVOID THE USE OF JUNCTION BOXES ABOVE DRYWALL GEILIN6 AREAS, JUNCTION BOXES LOCATED ABOVE LAY -IN CEILINGS ARE AGGEPTABLEJ I. MINIMUM 51ZE5 OF CONDUITS SHALL BE 3/4" FOR STANDARD CONDUIT, AND 1/2" FOR FLEX CONDUIT (1/2" STANDARD CONDUIT AND 3/8" MG GABLE MAY BE USED AS 5PEGIFIED ABOVE, IF ACCEPTABLE WITH LANDLORD AND LOCAL CODES, ELECTRICAL CONTRACTOR SHALL FIELD COORDINATE WITH LANDLORD d INSPECTION A6ENGIE5 PRIOR TO INSTALLATION). ELECTRIC, METALLIC TUBING (EMT) SHALL BE GALVANIZED OR ELECTRO-GALVANIZED. FITTIN&5 SHALL BE SET SCREW OR COMPRESSION TYPE, FITTING SHALL BE AS MANUFACTURED BY -REEL, STEEL CITY,-RACO, T 8 B, EFCOR OR EQUAL. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE SUSPENDED CEILINGS OR CONGEALED IN INTERIOR PARTITIONS. 2. PAINTING OF ELECTRICAL CONDUITS, ETC., IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. C. THE USE OF MC, ROMEX OR BX GABLE 15 NOT PERMITTED. D. MAXIMUM CONDUIT HANGER SPACIN& SHALL BE &'-0" FOR 3/4" THRU 1-1/4" AND 10'-O" FOR 1-1/2" THRU 4" CONDUITS. DO NOT SUPPORT CONDUIT FROM THE GEILIN6 SYSTEM. E. LEAVE A #10 A1,46 PULL WIRE OR NYLON PULL STRING IN ALL EMPTY CONDUITS. F. SECURE ALL RACEWAYS TO THE BUILDING STRUCTURE IN A RIGID AND SECURE MANNER, U51N6 FASTENERS SUCH AS "CADDY CLIPS" OR EQUAL. C. FLASH AND COUNTERFLA5H ALL RACEWAYS WHICH PENETRATE THE ROOF OR USE PITCH POCKETS. INSURE THAT PENETRATIONS ARE COMPLETELY WEATHERPROOF. ALL RACEWAY SYSTEMS EXPOSED TO THE WEATHER SHALL BE WEATHERPROOF. PRIOR APPROVAL BY LANDLORD 15 REQUIRED TO ADD ADDITIONAL EQUIPMENT LOADS TO 5TRUCTURE OR TO MAKE HOLES IN EXISTING ROOF. NOTIFY LANDLORD'S ROOFING CONTRACTOR AT LEAST 12 HOURS PRIOR TO ANY REQUIRED ROOF WORK. WIRE: A. WIRE SHALL BE SINGLE CONDUCTOR GOPPER WITH 600 VOLT INSULATION. MINIMUM WIRE H N H R SIZE SHALL BE 12 AW6, ALL WIRE AND GABLE SHALL BE NEW AND SHALL BE B OUCHTT O THE SITE IN UNBROKEN PAGKA6E5. ALL WIRING OF ANY TYPE SHALL BE IN CONDUIT. NO STRANDED WIRE ALLOWED FOR #10 AND #12 AW6 SIZES. (INCREASE CONDUCTOR BY ONE 51ZE FOR EVERY 150' INCREMENT OF 015TANCE FROM THE PANEL BOARD FOR 120 VOLT CIRGUITSJ I. GENERAL WIRING SHALL BE THIN OR THHN. (ALUMINUM CONDUCTORS ARE NOT PERMITTED) B. WIRE CONNECTORS SHALL BE EQUAL TO 5COTCHLOGK FOR #& AND SMALLER, AND EQUAL TO T sI B "LOCK-TITE" FOR #6 AND LARGER. G. THE USE OF SHARED NEUTRALS 15 ACCEPTABLE FOR LIGHTING AND RECEPTACLE CIRCUITS IF INSTALLED IN ACCORDANCE WITH N.E.G. #310, AND LOCAL CODES. D. ALL WIRIN6 TO BE COLOR CODED AS FOLLOWS: 120/208 VOLT SYSTEM 211/480 VOLT SYSTEM NEUTRAL - WHITE NEUTRAL - GREY PHASE A OR LI-BLACK PHASE A - 13ROWN PHASE B OR L2-RED PHASE B - ORANGE PHASE G OR L3-BLUE PHASE C - YELLOW &ROUND -GREEN GROUND - GREEN OR GREEN WITH YELLOW STRIPE LI6HTIN6: A. LIGHTING FIXTURES AND LAMPS SHALL BE FURNISHED AS SCHEDULED ON THE LIGHTING FIXTURE SCHEDULE. (THE MAJORITY OR THE FIXTURES AND LAMPS ARE FURNISHED BY THE TENANT) ELECTRICAL CONTRACTOR SHALL INSTALL ALL FIXTURES AND LAMPS. FLUORESCENT FIXTURES SHALL HAVE HPF BALLASTS WITH EFFICIENCY FACTORS IN ACCORDANCE WITH "INTERNATIONAL ENERGY CONSERVATION CODE 2001." B. LIGHT FIXTURES SHALL BE SUPPORTED FROM THE BUILDING STRUCTURAL VIA ALL THREAD AND UNI-STRUT, AND NOT SUPPORTED BY GEILIN6 SYSTEM. WIRED GROUND SYSTEM: A. FURNISH AND INSTALL A COMPLETE WIRED &ROUNDIN& SYSTEM FOR ELECTRICAL EQUIPMENT AND CIRCUITS AS SHOWN ON THE DRAWINGS AND DESCRIBED GENERALLY BELOW. B. ALL GROINDIN& CONDUCTORS SHALL BE GREEN, WHERE EXPOSED IN PANEL, SWITCHBOARD, OUTLET, BOXES, ETC. C. ALL ENCLOSURES AND NON -CURRENT GARRYIN6 METALS TO BE GROUNDED. CONDUIT SYSTEM TO BE ELECTRICALLY CONTINUOUS. ALL LOCK NUTS MUST GUT THROUGH ENAMELED OR PAINTED SURFA4,E5 ON ENCLOSURES. WHERE ENCLOSURES AND NON -CURRENT GARRYIN6 METALS ARE 150LATED FROM THE CONDUIT SYSTEM, U5E BONDING JUMPERS WITH APPROVED CLAMPS. D. RUN A SEPARATE &ROUNDING CONDUCTOR IN EACH CONDUIT, #12 MINIMUM, OR AS SHOWN ON ORAWIN&5. FOR PANEL FEEDERS BOND THE &ROUNDING CONDUCTOR TO THE CONDUIT, WHERE ENTERING AND LEAVING THE CONDUIT. ALL GROUND CLAMPS SHALL BE PENN-UNION OR EQUAL, 5lMILAR TO "6PL" TYPE. CONDUIT &ROUND BU5HIN65 SHALL BE THOMAS 8 BETTS OR EQUAL, SIMILAR TO #3800 SERIES WITH NYLON INSULATED THROAT. E. ALL DEVICES SHALL BE BONDED TO THE CONDUIT SYSTEM. USE A BONDING JUMPER BETWEEN THE OUTLET BOX AND THE DEVICE &ROUNDING TERMINAL. METAL -TO -METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX 15 NOT ACCEPTABLE AS A BOND FOR EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. ALL JUNCTION BOXES, OUTLET BOXES AND PULL BOXES SHALL BE BONDED TO THE CONDUIT SYSTEM. ALL FLEXIBLE CONDUIT SHALL BE JUMPERED WITH A GROUND CONDUCTOR. WIRE DEVICES - A. COLOR OF WIRING DEVICES AND COVERPLATES SHALL BE SELECTED BY DESIGNER. (SEE PLAN NOTES FOR ADDITIONAL INFORMATION). I. RECEPTACLES IN THE STOCK ROOMS AMC) BACK OF HOUSE AREAS SHALL BE 20 AMP, 3-WIRE &ROUNDING TYPE EQUAL TO HUBBELL 5362. 2. RECEPTACLES LOCATED ON THE WALLS OR AT THE RE&ISTER5 OF THE SALES FLOOR AREA SHALL BE 20 AMP 3-WIRE &ROUNDING TYPE WITH INDIVIDUAL CHILDPROOF SLIDING COVERS, EACH OUTLET. THE FACEPLATE5 SHALL BE WHITE TYPE EQUAL TO LEVITON #541000-1 OR ENGINEER APPROVED EQUAL. 3. SWITCHES SHALL BE 20 AMP SPECIFICATION GRADE, RATED AT 120 OR 211 VOLT, AS REQUIRED. 4. SPECIAL DEVICES SHALL BE SPECIFICATION &RAPE. 5. OCCUPANCY SENSOR SWITCHES SHALL BE SENSOR SWITCH #GM-PDT-10 MOTION AMC) SOUND DUAL TECHNOLO&Y. LINE VOLTAGE WALLBOX SEN50R SWITCH TYPE #W5X-WH RATED TO CONTROL UP TO 600 WATTS AT 211 VAG. UNITS SHALL HAVE ADJUSTABLE LIGHT LEVEL AND OFF -TIME. 6. FLUSH FLOOR MOUNTED POKE THROUGH OUTLET WITH 2 HOUR FIRE RATING. MOUNTS 4" DIAMETER HOLE. BLACK DEVICE WITH BRA55 CARPET FLANGE. PROVIDE MODIFIED LEXAN SLIDE HOLDER TO SUPPORT A DUPLEX ELECTRICAL OUTLET AND FOUR & PIN MODULAR TELECOMMUNICATION JACKS. COMPLETE WITH ALL NEGE55ARY HARDWARE FOR COMPLETE INSTALLATION. EQUAL TO WIREMOLD RC-4 SERIES. 1. RECE55ED FLUSH WITH FLOOR MOUNTED OUTLET FOUR COMPARTMENT STEEL BOX WITH 2 HOUR FIRE RATING. BLANK BRA55 COVER CARPET FLANGE. PROVIDE HOLDERS TO SUPPORT A TWO (2) DUPLEX ELECTRICAL OUTLETS AND FOUR 5 PIN MODULAR TELECOMMUNICATION JACKS. COMPLETE WITH ALL NEGE55ARY HARDWARE FOR COMPLETE INSTALLATION. EQUAL TO LE&RANO RFB4 SERIES. 8. EQUAL BY ARROW -HART, GENERAL ELECTRIC, BRYANT, PA55 a SEYMOUR, OR SIERRA. PANELBOARD5 AND SAFETY SWITCHES: A. PROVIDE BRANCH CIRCUIT PANELS WHICH SHALL BE OF THE BOLTED CIRCUIT BREAKER TYPE WITH SOLID COPPER BU551N& FULL SIZED NEUTRAL, 25% GROUND SU55INC, OVERALL HIN&ED/LOCKABLE DOOR, AND TYPEWRITTEN DIRECTORY IN51DE DOOR. ALL SERVICE ENTRANCE EQUIPMENT SHALL BEAR THE MANUFACTURER'S LABEL WHICH SHALL STATE THAT THE EQUIPMENT 15 RATED FOR SERVICE ENTRANCE APPLICATION IN ACCORDANCE WITH N.E.G. #230-10. LOAD BALANCE ALL ELECTRICAL PHASES AT PANELS AND SWITCHBOARDS. TWO AND THREE POLE BREAKERS SHALL BE COMMON TRIP TYPE. WHEN USED AS SWITCHES IN 12OV. AND 211V. LICHTIN& CIRCUITS, FURNISH TYPE "5WD" BREAKERS IN ACCORDANCE WITH N.E.G. #240-&35. SQUARE D OR EQUAL BY SIEMENS ITE, CUTLER -HAMMER, OR GENERAL ELECTRIC (OR APPROVED EQUAL. PROVIDE SAFETY AMC) 015CONNECT SWITCHES, FUSED OR NONFU5ED, B. AS GALLED FOR ON DRAWINGS AND AS-REQUIREO BY CODE. (FUSES AS MANUFACTURED BY BU%MAN, CHASE SHAWMUT, ECONOMY FUSE CO., OR LITTLE FUSE CO. ARE ACCEPTABLE). 015GONNECT SWITCHES THAT ARE INSTALLED AT AIR CONDITIONING EQUIPMENT, HEAT PUMPS, ETC SHALL BE FUSED IN ACCORDANCE WITH THE EQUIPMENT'S NAME PLATE REQUIREMENTS PER N.E.G. 440 21 d 110-313. SWITCHES SHALL BE HEAVY DUTY, QUICK MAKE/QUICK BREAK TYPE, FUSIBLE OR NON -FUSIBLE, WEATHERPROOF AS INDICATED ON THE DRAWIN65, OR A5-REQUIRED BY LOCAL CODES. LOAD AND HORSEPOWER RATED AS MANUFACTURED BY SQUARE D, SIEMENS ITE, CUTLER HAMMER, OR GENERAL ELECTRIC (OR APPROVED EQUAL). C. MANUAL MOTOR STARTERS WITH OVERLOAD PROTECTION MAY BE USED FOR FRACTIONAL HORSEPOWER MOTORS THAT DO NOT REQUIRE AUXILIARY CONTROL. 51N&LE PHASE STARTERS SHALL BE SQUARE D OR EQUAL. THREE PHASE STARTERS SHALL BE PROVIDED WITH OVERLOAD DEVICE IN EACH PHASE MATCHED TO MOTOR NAMEPLATE -RATING. MAGNETIC MOTOR STARTERS (MINIMUM SIZE #I) SHALL BE USED FOR ALL SINGLE PHASE AND THREE PHASE MOTORS RATED ABOVE 1/2 HP OR THAT REQUIRE AUXILIARY CONTROL. PROVIDE CONTROL DEVICES (CONTACTS, TRANSFORMERS, ETGJ IN STARTERS AS REQUIRED FOR INTERLOCKS, COORDINATE WITH MECHANICAL AND/OR TEMPERATURE CONTROL CONTRACTORS. COMBINATION STARTERS, WHEN USED, SHALL CONTAIN FUSIBLE SWITCHES. BOXES. - A. OUTLET BOXES AND COVERS SHALL BE GALVANIZED, ONE-PIECE PRESSED STEEL KNOCKOUT. B. JUNCTION, PULL BOXES AND GOVER5 SHALL BE GALVANIZED STEEL, CODE 6AU&E SIZE. G. INSTALL BOXES -RICIDLY ON BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. AL50 PROVIDE SUITABLE/PROPER BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF WALLS ETC. ALL OUTLET BOXES TO HAVE SUITABLE BLOCKING BEHIND THEM TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLU66IN6/UNPLU&&IN6 INTO THESE DEVIGE5. D. WHERE A 211 VOLT LIGHT SWITCH 15 GANGED WITH A 120 VOLT RECEPTACLE PROVIDE A SUITABLE DIVIDER OR SEPARATE JUNCTION BOXES IN ACCORDANCE WITH NEC AND LOCAL CODES. 5ERVIGE5: A. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE FROM LANDLORD'S DE516NATED LOCATION AND PROVIDE LIGHTING, POWER AND WIRING AS REQUIRED TO FACILITATE APPLICABLE TEMPORARY NEEDS, AND FURNISH EXTENSION CORDS. ANY TEMPORARY WIRIN6, FUSES, ETC., SHALL BE REMOVED UPON COMPLETION OF THE PROJECT. PROVIDE GROUND FAULT PROTECTION AS REQUIRED BY N.E.G. AND LOCAL CODES. B. PROVIDE ELECTRICAL SERVICE AS SHOWN ON THE DRAWINGS, FIELD VERIFY EXACT -REQUIREMENTS PRIOR TO BIDS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE ENTIRE INSTALLATION WITH LANDLORD AND POWER COMPANY AS REQUIRED. (PROVIDE EQUIPMENT THAT 15 COMPATIBLE WITH AVAILABLE FAULT CURRENT LEVELS, PROVIDE 'GABLE LIMITERS' IF NEGE55ARY FOR SYSTEM COORDINATION). FIELD VERIFY EXACT TYPE, SIZE, LOCATION, REQUIREMENTS, ETC. OF EXISTING POWER AND TELEPHONE FACILITIES PRIOR TO BIDDING PROJECT. G. MAKE PROVISIONS FOR NEW TELEPHONE SERVICE AS REQUIRED, AND AS INDICATED ON THE DRAWINGS. D. CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION WITHIN TENANT'S PREMISES SHALL BE PROVIDED AS REQUIRED FOR A COMPLETE TELEPHONE SYSTEM. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. CLOSELY FIELD COORDINATE WITH TENANTS CONSTRUCTION MANAGER TO AVOID CONFLIGT5. LI&HTIN& CONTACTOR AND TIMER SWITCHES: A. CONTACTORS FOR CONTROL OF LI&HTINC AND SIGNS SHALL BE SQUARE "D", CLASS bgO3, TYPE "L", ELECTRICALLY OPERATED AND ELECTRICALLY HELD. EQUIVALENT PRODUCTS BY OTHER MANUFACTURERS ARE PERMITTED. B. TIME SWITCHES SHALL BE USED FOR CONTROL OF SHOW WINDOW LIGHTING, 516NS, PICK-o-BRICK (DISPLAY) LI&HTINC, BRAND RIBBON (DISPLAY) LIGHTING, AND GENERAL SALES FLOOR LIGHTING AS INDICATED ON PLANS. THE TIMER SHALL BE A TORK MODEL 06100A OR EQUIVALENT WITH A MINIMUM7-DAY FORMAT AND CAPABLE OF l DIFFERENT DAY TYPES PER WEEK WITH AN AUTOMATIC HOLIDAY "SHUT-OFF" FEATURE. TIME CLOCK SHALL HAVE PROGRAM BACK-UP THAT SHALL MAINTAIN PR06RAM AND TIME SETTINGS FOR A MINIMUM OF 10 HOURS, WHEN POWERED 15 INTERRUPTED. TIME CLOCK SHALL AL50 BE POWERED BY A SELF-STARTING SYNCHRONOUS MOTOR, AND CAPABLE OF REIN& SET FOR DIFFERENT ON -OFF TIMES EACH DAY OF THE WEEK. SET TIMECLOGK AT OPENING FOR lAM ONAIPM OFF, OR AS OTHERWISE DIRECTED BY DESIGNER. FLOOR MOUNTED BOXES: A. FOR AREAS WHERE THERE IS ACCESS FROM THE FLOOR BELOW PROVIDE A WIREMOLD 6AT WITH A 6TRAC INSERT. COORDINATE EXACTION LOCATION OF THE OF THE POKE THROUGH WITH THE OWNER AND THE DE516NER. B. FOR AREAS WHERE THERE 15 NO ACCESS FROM THE FLOOR BELOW TRENCH THE FLOOR. FLOOR BOXES SHALL BE WIREMOLD RFB4 WITH TWO (2) RFB-DR DUPLEX POWER BRACKETS AND TWO (2) DTB 2 2RT COMMUNICATION BRACKETS. COORDINATE THE EXACT LOCATION OF THE FLOOR BOX WITH THE OWNER AND THE DE516NE.R. G. PATCH AND FINISH FLOOR AS REQUIRED. D. COORDINATE FLOOR CONSTRUCTION WITH OWNER AND THE NEI6HBORIN6 TENANTS INGLUDIN6 TENANT ON THE FLOOR BELOW. INSTALLATION: A. ALL ELECTRIC WORK SHALL BE INSTALLED 50 AS TO BE READILY ACGE551BLE FOR OPERATING, 5ERVIGINC, MAINTAINING AND REPAIRING. HANGERS SHALL INGLUDE ALL MISCELLANEOUS STEEL SUCH AS GHANNEL5,-ROOS, ETC., NEGE55ARY FOR THE INSTALLATION OF WORK AND SHALL BE FASTENED TO BUILDING STEEL, CONCRETE OR MASONRY, BUT NOT PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONGEALED WHEREVER POSSIBLE. EXP05ED CONDUITS SHALL BE IN STRAIGHT LINES PARALLEL WITH OR AT R16HT AN&LE5 TO COLUMN LINES OR BEAMS AND SEPARATED AT LEAST 3 INCHES FROM WATER LINES WHEREVER THEY RUN ALONGSIDE OR ACROSS SUCH LINES. ALL CONDUCTORS SHALL BE IN CONDUIT, DUCTS OR OTHER CODE APPROVED RACEWAYS. B. ALL LINE AND LOW VOLTAGE POWER AND CONTROL WIRING (EXCEPT HVAG LOW VOLTAGE WIRING) INCLUPINC GONNEGTION5 TO MOTORS, DAMPERS, INTERLOGKIN6, ETC., SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. (ALL LINE VOLTAGE WIRIN6, CONDUIT, AND FINAL CONNECTIONS FROM THE POWER SOURCE THRU THE 5TARTER/015GONNEGT ETC. TO THE MOTOR OR EQUIPMENT 15 THE RESPONSIBILITY OR THE ELECTRICAL CONTRACTOR. ALL HVAC -RELATED LOW VOLTAGE CONTROL WIRIN6, CONDUIT AND FINAL CONNECTIONS 15 THE RESPONSIBILITY OF THE MEGHANIGAL/TEMPERATURE CONTROL CONTRACTOR, UNLE55 OTHERWISE NOTED ON THE PLANS). C. THE ELECTRICAL CONTRACTOR SHALL DO ALL GUTTIN6, GHASINC OR GHANNELIN6 AND PATCHING REQUIRED FOR ANY WORK UNDER THE ELECTRICAL DIVISION, ANY GUTTING SHALL HAVE PRIOR APPROVAL OF THE LANDLORD. SLEEVES SHALL EXTEND AT LEAST TWO (2") INCHES ABOVE FINISHED FLOOR AND ALL SLEEVES, OPENINGS, ETC., THROUGH FIRE RATED WALLS AND FLOORS SHALL BE FIRE SEALED WITH CALCIUM 51LIGATE, 51LIGONE "RTV" FOAM, '3M" FIRE -RATED 5EALANT5 OR EQUAL BY HILTI AFTER CONDUIT/GABLES INSTALLATION 50 AS TO RETAIN THE FIRE RATING. D. THE ELECTRICAL CONTRACTORS, INSOFAR AS THE WORK IS GONGERNED, SHALL AT ALL TIMES KEEP THE PREM15E5 IN A NEAT AND ORDERLY CONDITION AND, AT THE COMPLETION OF THE WORK, SHALL PROPERLY GLEAN UP AND CART AWAY ANY DEBRIS AND EXCESS MATERIAL. E. THE FOLLOWING EQUIPMENT SHALL BE IDENTIFIED WITH ENGRAVED BAKELITE NAMEPLATES AS TO NAME AND/OR FUNCTION; 015TRIBUTION PANELS, LI&HTINC PANELS, MOTOR 5TARTER5 AND 015CONNECT SWITCHES. NAMEPLATES TO BE APPROXIMATELY I" x 2" IN 51ZE AND BE FASTENED WITH POP RIVETS OR SCREWS. F. THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE AND THE DE5167NER/TENANT CONSTRUCTION MANAGER SHALL HAVE THE RIGHT TO -RELOCATE ANY OUTLETS OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. C. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANCES IN THE WORK AS THE JOB PROC-)RE55E5, AND TURN THI5 "AS BUILT" INFORMATION OVER TO THE OWNER AT THE COMPLETION OF THE PROJECT. H. ELECTRICAL CONTRACTOR SHALL PROTECT ALL FIXTURES/EQUIPMENT AGAINST DAMAGE FROM LEAKS, ABUSE, ETC., AND PAY COST OF REPAIR OR -REPLACEMENT OF FIXTURES OR EQUIPMENT MADE NEGE55ARY BY FAILURE TO PROVIDE SUITABLE SAFEGUARDS OR PROTECTION. I. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELEGTRIGAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. AFTER ALL EQUIPMENT HAS BEEN INSPECTED AND APPROVED, THOROUGHLY GLEAN ALL EQUIPMENT PROVIDED UNDER THI5 WORK JUST PRIOR TO COMPLETION OF PROJECT. J. THE ELECTRICAL CONTRACTOR 15 RESPONSIBLE FOR ANY/ALL NEGE55ARY ELECTRICAL DEMOLITION WORK THAT 15 REQUIRED TO FACILITATE THE NEW INSTALLATION, FIELD COORDINATE PRIOR TO BIDS. REMOVE AND/OR MODIFY EQUIPMENT, ETC. AS -REQUIRED FOR A COMPLETE INSTALLATION. ANY EQUIPMENT OR DEVICE REMAINING IN USE AFTER PART OF THE EQUIPMENT OR DEVICES HAVE BEEN REMOVED ARE TO BE RECONNECTED TO EXISTING OR NEW CIRCUITS AND LEFT IN WORKING ORDER. FEEDERS TO PANELS AND WIRING TO OTHER EQUIPMENT TO BE -ROUTED CONGEALED IN FINISHED AREAS. COORDINATE ANY 015RUPTION OF ELECTRICAL OR TELEPHONE 5ERVIGE5 WITH LANDLORD AND TENANT CONSTRUCTION MANAGER TO AVOID CONFLICTS. GUARANTEE: A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE (I) YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THE ELECTRICAL CONTRACTOR'S EXPENSE. B. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND/OR INSTALLED BY THE ELECTRICAL CONTRACTOR. FINALLY: A. IT 15 THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR 5HOWN ON THE DRAWIN65, BUT NEGE55ARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. R p �pO�P►C,000 pR�y�� �► MAR 16 ti�15 NG Q�v1c,,0 RECEIVED CITY OF TUKWILA FEB 2 6 2015 -PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED Plotted on Recucled Pover ry � QI � z � ry In W O z < W W Q W 0 ZO Z tY m0 0 W13 W<mryry W Null V ryryry J W N N OL W W z_ U z w w ■ W.E ASSOCIATES II, L.L.C. 281 Farmington Avenue Farmington, CT. 06032 SHEET NO. FAI