Loading...
HomeMy WebLinkAboutPermit D15-0081 - COURTYARD BY MARRIOTT - BAR AND LOUNGE SEPARATION16038 W VALLEY EI\VY D15-0081 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 0005800005 Permit Number: D15-0081 Address: 16038 W VALLEY HWY Issue Date: 5/26/2015 Permit Expires On: 11/22/2015 Project Name: COURTYARD BY MARRIOTT Owner: Name: CSM CORP Address: 500 WASHINGTON AVE #3000 C/O STEFFEN TERRY, MINNELPOLIS, MN, 55415 Contact Person: Name: ROB GULNER Address: 500 WASHINGTON AVE, SUITE 3000, MINNEAPOLIS, MN, 55415 Contractor: Name: FURNITURE FIXTURE SERVICES INC Address: 1493 NE CLEVELAND, GRESHAM, OR, 97030 License No: FURNIFS871BT Lender: Name: N/A LESS THAN $5,000 Address: "I , DESCRIPTION OF WORK: Phone: (612) 395-7000 Phone: (503) 572-5458 Expiration Date: CONSTRUCT HALF WALL SEPARATING BAR AREA FROM LOUNGE. FILL IN HOT TUB. RELOCATE WINDOW WALL. Project Valuation: $4,800.00 Fees Collected: $324.62 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: Occupancy per IBC: R-1 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: ��cl .( X �C�l�- �� Date:_�`l�` I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development p it a g;Z7 tditi s attached to this permit. Signature: t I Date: � 6' oiC Print Nam a J�%l7 nkL �h@ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 12: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 22: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 18: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 16: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 15: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 20: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 21: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 23: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during demolition and construction. 17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 24: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at(206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 0301 CONCRETE SLAB 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 4046 SI-EPDXY/EXP CONC 0406 SUSPENDED CEILING CITY OF TUK"LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 " TuAnvila, WA 98188 http:/hN-�Ntiv.TukwilaWA.gov SITE LOCATION Building Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use oni}) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" j�L_�/J �l (/JKing Co Assessor's Tax No.: Site Address: / (C�� (/ � 1/iJ� / l ! W11 / Suite Number: Floor: Tenant Name: M) / , New Tenant: ❑ .....Yes PROPERTY OWNER Name: //)� l,, Address:/►G J(�Vl� City: /� / L State: / Zip' CONTACT PERSON — person receiving all project communication Name: Address:,_ �A�1/-,7PP 1� City//V pLSttate:4Ww) ZiT� Phone:(/2 _ 2vFax: Email: /U G /V /M, A GENERAL CONTRACTOR INFORMATION Company Name: �5 /N� Address: /L%c7lc City: " Sttlattee:-f�/ uv Zip Phone: �l�� -ax: Contr Reg No. L)Ke 1 l$7 Date: 3 30ZI 7 Tukwila Business License No.: ARCHITECT OF RECORD Company Name:Off Architect Name: Address�� City: �j� �State: /v Zip Phone:x? /_� Fax: Email IJ{�L'� ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 1.9.27.095) Name: Address: City: State: Zip: H:\ApplicalionsWorms-Applications On Line\2011 ApplicationsTermit Application Revised - 8.9.1 Ldocs Revised: August 2011 Page 1 of 4 hh BUILDING PERMIT INFORMATION — 206431-3670 Valuation of Project (contractor's bid price): Describe the scope of work (please provide detailed information): ' Existing Building Valuation: Will there be new rack storage? ❑..... Yes �.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l' Floor 2 Floor 3'd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:_ *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑....... Yes ❑....... No If "yes", explain:_ FIRE PROTECTIONMAZARDOUS MATERIALS: X...... Sprinklers A....... Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑....... Yes No If "yes, attach list of materials and storage locations on a separate 8-112 " x 11 "paper including quantities and MaterialAflolata Sheets. SEPTIC SYSTEM ❑ ....... On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Re% iced - 8-9-1 I.docx Revised: August 2011 Page 2 of 4 bh PUBLIC WORKS PERMIT INFORMATION - 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑... Water District #125 ❑ .. Highline ❑ . Renton ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑... Valley View ❑ . Renton ❑ .. Seattle ❑ ...Sewer Use Certificate El ... Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which anol ❑ ...Civil Plans (Maximum Paper Size — 22" x 34" ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ .. Right-of-way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection _ Irrigation Domestic Water ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size.. WO # ❑ ...Water Only Meter Size............ WO # ❑ ...Sewer Main Extension ............. Public ❑ Private ❑ ❑ ...Water Main Extension.............Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑... Deduct Water Meter Size " Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: City State Zip Day Telephone City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 Ldocx Revised: August 2011 Page 3 of 4 bh PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW E O AGENT: w � ; Signature: Date: Print Print Name: / "'F'/t'�/y�' !�"S`�/% Day Telephone:�/U3— Mailing Address: City State Zip H:\Applications\Forms-Applications On Line\2011 ApplicationsTermit Application Revised - 8.9-1 I.docx Revised: August 2011 Page 4 of 4 bh DESCRIPTIONS PermitTRAK PAID $202.22 D15-0081 Address: 16038 W VALLEY HWY Apn: 0005800005 $202.22 DEVELOPMENT $192.80 PERMIT FEE R000.322.100.00.00 0.00 $188.30 WASHINGTON STATE SURCHARGE 13640.237.114 0.00 $4.50 TECHNOLOGY FEE $9.42 TECHNOLOGY FEE TOTAL FEES ' 4' R000.322.900.04.00 0.00 $9.42 Date Paid: Tuesday, May 26, 2015 Paid By: CSM CORPORATION Pay Method: CREDIT CARD 065795 Printed: Tuesday, May 26, 2015 9:23 AM 1 of 1 Cf J�J w, srsrEMs Date Paid: Thursday, April 02, 2015 Paid By: ROBERT EVENSON Pay Method: CREDIT CARD 04648G Printed: Thursday, April 02, 2015 9:58 AM 1 of 1 II • L�SYS7EM5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projec � * j V-AJ Type of Inspe 'on: , 7 14z-- Address: 6 3 �v l�•e D t Called: Special Instructions: Date anted: a„ , p.m. Requester: Phone No: pproved per applicable codes. El Corrections required prior to approval. �C INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro' J �N�� A' /® Type of Insp ion: % Address: Date Called: Special Instructions: Date Wanted: / ni. 6 p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 1015 Retain a copy with permit 008'J INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projec : i Type of ins p coon- Address: 1603 �/ V�� /" Date Called: Special Instructions: Date Wanted: a.m ` .m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. lJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 46 INSPECTION RECORD ��� Q��r Retain a copy with permit (C3-) I' INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect: %'(o "Vc�� Type o spection: V-'s VqA Add s�s ®c��!/� C� Date Called: Special Instructions: F Date Wap ed: , ,`. a.m. (� p.m. Requester: Phone No: (inspector: IDat6 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. DO -0-1 INSPECTION RECORD OOE) 3 Retain a copy with permit INSPECTION NO. PERN41T NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project7-- Ll le Type o pection: - IAd ess: 1-1 Vq OT6 ( Ite coiled: Special Instructions. I Date Wanted: a.m. 6 p.m. k1eque 1�r-. VK( ( AA Phone No: _(6— REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. CaH to schedule reinspection, 31. INSPECTION RECORD Pfs-- cjdg Retain a copy with permit If4JUKTION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project. Pilo Type'af Inspec Ion, t' Ge( N"q Address- f Y ((, 0 3 b (et L/ 'j Date LallerJ: Special Instructions: /�j Date w e a.m. p.rn, Requester, P one No: 1:1 Approved per applicable codes. 1-1 Corrections required prior to approval, � 6( — (T- REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Catt to schedule reinspection. L10 INSPECTION RECORD �(�— Gd� l IQSPECT16N NO. lRetain a copy with permit PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 1 (206) 431-3670 Permit Inspection Request Line (206) 436-9350 � / — 4 7< '-/ PZo,ect,--- flom i 7 4 -1--( IAddress: U ( 6 6 3 F) Dim- Called: Special Instruc ions. DatFW—anted- a.m. --q p.m. Requester'. J54 C, ( & ELAM TC)O Phone No: A -Al , .11 .............. n 3 3-7 ZS - 0 Approved per applicable codes. Corrections. required prior to approval. COMMENTS. /Vol— ��-�,� � �� cam. � _ ,dam c' .......... 5�? 7 oE'er f-rd REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd- Suite 100, Catt to schedule reinspection. INSPECTION RECORD 1)1S- -yoeY l Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: CO U A v VV ('4 i— Type of Inspection: i +w Address: v(a Contact Person: Suite #: a Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 19 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: % „ �7 Date: I Hrs.: ❑ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: I State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORD /- S J 08i Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT %' 1 rh ),!`A-\r./J 1— 206-575-4407 Project: ` Type of Inspection: Address: Contact Person: Suite #: Special Instructions: Phone No.: Approved per applicable codes. COMMENTS: 4A-Eorrections required prior to approval. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: inspector:/5'�-- Date: Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. timing Aaaress Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0081 DATE: 04/02/15 PROJECT NAME: COURTYARD BY MARRIOTT SITE ADDRESS: 16038 W VALLEY HWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: I Auldig n Division 0 ; ,w ft P tO-K ow Works a PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: A* hv,N , Fire Prevention Structural ❑ CPL, P1lt- *-1-d Planning Division Permit Coordinator a DATE: 04/07/15 Structural Review Required ❑ DATE: DUE DATE: 05/05/15 Approved with Conditions Dd Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: I V18/2013 FURNITURE FIXTURE SERVICE"'IC Page 1 of 2 Washington State Department of Labor & Industries Hone Inicio en Espanol Contact Search L&I A-ZIndex Help My SecureI&I Safety Claims & Insurance Workplace Rights Trades & Licensing FURNITURE FIXTURE SERVICES INC Owner or tradesperson 1493 NE CLEVELAND HERRADA III, FELIX ANTONIO GRESHAM, OR97030 503-572-5458 Principals HERRADA III, FELIX ANTONIO, PRESIDENT WA UBI No. Business type 603 269 852 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ................................._...................................... Meets current requirements. License specialties GENERAL License no. FURNIFS871BT Effective — expiration 01/30/2013— 03/30/2017 Bond ... .............. Wesco Insurance Co $12,000.00 Bond account no. 46W BO14590 Received by L&I Effective date 01/30/2013 01/22/2013 Expiration date Until Canceled Insurance ...................._... West American Ins Co $1,000,000.00 Policy no. BKW53641591 Received by L&I Effective date 05/06/2014 05/31/2013 Expiration date 0513112015 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the 1.bond or savings accounts during the previous 6 year period. L&I Tax debts .. ... ............. No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations .............. ............. No license violations during the previous 6 year period. Workers' comp https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603269852&LIC=FURNIFS871BT&SAW= 5/26/2015 VICINITY MAP CODE REVIEW SHEET • INDEX PROJECT PARTICIPANTS C ,� }sota sc t . _ PROJECT DE5GRIPTIDN: M1.1iS ,.. fay i O 15 AN EXISTIN6 HOTEL DEVELOPMENT IN TUKWILA WA THAT NG, INC. pt �. x.... COLRTY,4RD BY MARRI TT , AO O OVER SHEET O GSM LODGI s � s�-E .-,,.00 ARCHITECTURAL 500 W,SHINGTON AVE.AYE 5., SUITE 3 , - ^••....rrn'rs' .,_�..� � .._ DE iNG THEIK BAR 4 SPA AREA CONVERTING THE SPA AREA INTO A LARGER :., �. ..._„., , ,. ,. _ MINNEAt OLIS MN 554.15 . „., ,. � , ..,.1�1,, z :�. � � .._. .,. ,., ,, 4F� �s AI O OVERALL FLOOR PLAN � , - yS f.. .. :...�: �;lui�rr ��„ . FITNESS ROOM. ,:, ,, .:...(NPf1 4.: 1 .. ,..f ,. �.. t .... _, :: �>.� d na ita� G�!%�.`�' �Ci/ i�%�'S �1' DEMOLITION PLAN PHONE• 612 3q5 7000 f 515ns1 fit... L J 7 t' �. r / `� ! + } t� _:- _..:.:,, C �...,..:. Corr: -ray , T,viatact;hild :. }. t / to M,.« it - '_:,, i, f}�, r - : L . r� .5--1002 �c.. • awia svv ��th SL AI.I FLUOR REFLECTED FAX: 61 3q :r..: •.'�', rl/r'.. .'... r.: ;,', '.. fiy ri��c.r5" _ :. _. �• y.Uai-d€r.,!I/.u._.... F.1,194,i. 1.•r 3 x.�_,�.= r P.tc enu. H n.�ns r, , r F , trs . APPLICABLE CODES r ... ' ' q ,... _ ran!1$j Fu r C• nt fa v CEILING PLAN PROJECT MANAGER: ROBE 6ULNER 500 Washlnaton Avenue South, Suite soon .._ i..r :,. •:.._ S. W (.�. - rj1 :.!.- nentrarz ''�... g 153rd St ..: , P w s .. : , , _ _ :. J�'� � �: 2 t� t 2� IBC W/STATE AMEtyDMENTS A2.0 I TERI A � ELECTRICAL GR CSM 8lnntbapolfe,MN55415 us: (812)$95 7000 Fax: (612) 395 7002 E; f� .;. :. •. 2d t2' IFG W/STATE AMENDMENTS FINISH PLAN ARCHITECT: DEVELOPING REA4ESTATE FOR PEOPLE, �'. P E IEWE J F I1 BUSINESS & COMMUMTTES t ti IECG (ENERGY CODE) _.. �. COtI�PLtANCE ! n a 2A 51 AI I'1.1 500 WASHINGTON AYE. 5. SUITE 3000,O®E q . w .. .• n d .' b m APPROVED n- a,.• M , ,, 1 :.. r ..., .. U .. Sfl b 5 V ��Jt St • ! 167 ��®� .rr.., gl '. ,',+� ,f••..: _. 'rPLYS'aftf¢ — - n,- .. .� J - _ .. ''jj MINNEAPOLI MN 55415 4,. r t. �� .,w. , r . r P ; ; `.'� -'� ,: •m":51 t rUl '� a .. �: '� - 00 �,: � ,.. ;w. ,r� z¢ . �cw .... �,.. � n� ..�'..:. -•<; . � k , � EXISTING- BUILDING DESCRIPTION:. PHONE: 612 3q5 70 . , �s }.,?r . er t Ir.. ... �_ G ` .}r h ,::"."'.`!..:-v........... _ ..',"tuAynle ftnry.... J _ 1 �,. ti ii,, 1e, ....... _ , ! R 4 2015 R ® I t . r a t ,1 ,o ' c... *^ ' r �. :. yt r : I. x... .. �.nr m.'.>. k4, r,J r1 na. t;: — $r . _- rr 'bey W.a . , Lon r r 1Jer. FAX: $12 3q5-'7002 �, "t ,; tr. EIGHT STORY 5TEEL FRAME. EXTERIOR SKIN 15 EIFS SYSTEM. THE STRUG'NRE 15 OF TWO HOUR �1P 9 9 . I itaesrr. Lrnoarws 1nd:v.'!:naJ Park. �t--44,'•p :.�. sauthconler r.,�u .:. ; . !� : rW.... I �_ �, PROJECT ARCHITECT: JOHN PERKIER t ,J ry PROTECTED CONSTRUCTION WITH AUTOMATIC FIRE SPRINKLE SYSTEM. STAIR ENCLOSURES ARE l r :, f - Std,.,OFI a Tukwila Qr tG t 1 ts� . ! LOCAL CONSULTING ARCHITECT: Cit ofi `�ukw s iits t4a,t.c.d v TWO HOUR RATED. (� ; :r i _ Sorrt cnYer H . i ROBERT EYEN50N ASSOCIATES BUILDING DIVISION mill I, : ' :: . ! �; t 624q SW CANYON COURT � � - a� .. � — — EXISTIN6. OCCUPANCY CLASSIFICATION: GROUP R I / A 3 I l PORTLAND, OR q-r221 ,:a, � rl:: f ;' > `; ! _ (MIXED SEPARATED) PUM C-03 PHONE: 503-221-08g0 sJ t- $Ul]tltGlnlQII41.9�I s!, rntere $tikJ: PRQJEr**Th ada.lgSY t "' P t _;r S. 'aai C :Y a t. ARCHITECT: ROBERT EVENSON �... a + Se ::_ � . a r� Strander 97 t} . ti P yr N PROTECTED Ji �iamiart tLC a SIT"E 5, +27tta 51 �' EXISTIN6 CONSTRUCTION TYPE: TYPE 2 PROTE ti t r a S�a.hcrnEer. F,hz� SPRINKLERED 51TE: r R®g. No.. COURTYARD BY , MARRI OTT - 5EATAC Date: jr r� ¢M Trt Cli t`r . • :: .. �0 r 16038 WEST VALLEY HIGHWAY u tt,kii rtn e n (?ark ':..: ' o W 291h St Drawn 5: % JASON 15RUHN �t EX BUILDING SQUARE FOOTAGE: A. FIRST FLOOR 20,2q'i 5F TUKWILA, WA g8188 s q .SECOND FLOOR 14,663 SF PHONE: v _ �. 9ii F } cc. Dollar {• I R I Cheaked By. JOHN FERRIER B r> y:y G. TYPICAL FLOOR 5,861 SF (X6 FLOORS) FAX: i ! z NE M TOTAL 5Q. FT. AREA 130,3461 GSF Pro eat .Mans era N Nar'dstrctn, J NER rLt Cardi m Ellen Cnlicpr.'o, Ctai_.. 6E RAL MANAGER: S ( ti3.�4igSlvd .Kehly 5•vtfortl-6co,�rn': �+ ROBE 6UL I t: GENERAL CONTRACTOR: Date:' ' DULY 23 2014 �i k t t 31 5 it PHONE:'-5`lZ, y..8 R e v I s ions -FM h �lIGI1�ITY MAP _ _ REVISIONS � • GOT , Mo changes shall be, made tot e .scope 1( f% / � } AO.O SCALE: NTS c f ��}orl<^Iithoi�t prior approval of NORTH ( Tulmiia Building Division. f I �?TE: Revisions will require a new p!an submittal and ma include additionGl plan roview fees: Y _I �. RECEIVED XX-XXXX 1' IT 1 i r?°t5 r. CITY OF TUKWILA IYi Mcci',al�icul APR. 0 2 2015 [� Be tr ical P r o f 'e a t N o. lumbing PERMIT CENTER Gas Piping 5 h e e t T I t l e city of Tukwila COVER HEFT �?,i�19� ING DIVISION 9haat No. LI6HTIN6 KEY EXISTING 2' X 4' LAY-1N LIGHT FIXTURE -MATCH EXISTING FIXTURE FOR ALTERNATE I EXISTING GAN LIGHTING TO REMAIN. @ NEW CAN LIGHTING TO MATCH EXISTING GENERAL NOTES I. CENTER OF SWITCHES TO ' BE AT 42" A.F.F. U.N.O. 2. LOCATION AND'GUANTITY OF EXIT SIGNS TO BE REVIEVIED BY FIRE MARSHALL AND APPROVED BY OWNER. 5. ALL SWITCHES AND DEVICE PLATE- GOVER5 SHALL MATCH EXISTING IN COLOR. 4. REFER TO MATERIAL SCHEDULE FOR CEILING TILE SPECIFICATION. 5. ELECTRICAL CONTRACTOR TO VERIFY VOLTAGE REQUIREMENTS FOR v SPECIFIED FIXTURES. 6. ELECTRICAL DESICWBUILD SUBCONTRACTOR 15 TO VERIFY LIGHTING LEVELS OAND COORDINATE LIGHTING LAYOUT WITH TENANT. a — REFLECTED OE I L I NG FL ,N . KEY NOTE5 O EXISTING CEILING GRID TO REMAIN. REPLACE CEILING TILE5. O PROVIDE NEW BULK HEAD TO TRANSITION BETWEEN ACT AND GYP. BD. CEILING: BULK HEAD TO BE 2��BELOW EXISTING GEILIN , AND 61, WIDE. O ALTERNATE I - GUT IN OPENINC79 FOR NEW 2' X 4' LAY IN LIGHTS TO MATCH EXISTING LIGHTING IN FITNESS ROOM. . O CAN LIGHTING SHOWN SHADED REPRESENT NEW LIGHTS TO MATCH EXISTING LIGHTS. O EXISTING CEILING 4 LIGHTING -•NO WORK SWI=AGE TO BE 2" WOOD. CAP HIGHER .THAN 00-1) : TABLETOP (MATCH EXI5TING LINE OF TABLETOP COMMUNAL TOP) YWG 5/8" GYPSUM BOARD. m "/6" METAL STU05 24" O.G. BASE / OFLOOR INSPECTION FOR VERIFICATION OF DRILLED HOLES AND HOLE PREPARATION �A PARTIAL HEIGHT PARTITION WALL FOR EPDXY SHALL BE REQUIRED PRIOR TO INSTALLATION OF EPDXY AND RE -BAR NALL 7'rFE5 (OR BOLTS IF- APPLICABLE). 2 INSPECTION SHALL BE INCLUDED WITH ALI SGALE:.1/2"=1'-O" FOUNDATION OR CONCRETE INSPECTION. PROVIDENEW 5" CONCRETE FLOaRIN6 OVER SAND SASE �DOWEL NEW GONGPETE . IN SPA. SLAB INTO. EXISTING POOL AS SHOWN. DOWEL NEW CONCRETE ' f •, SLAB INTO, EXISTIN6 POOL , "L•: ..,„ ; : ;p 1 t r AS SHOWN. FILL SPA NiTH COMPACTED SAND. 9 SFA INFILL 5ECTI ON AI.I SGAI_61/4"=1'-O" KEY NOTES O INFILL EXISTING SPA. SEE B/AI.I ,FOR TYPICAL DETAIL. O RELOCATE GLAZING SYSTEM TO ONE OF THESE LOCATIONS. VERIFY BEST FIT FOR.WINDOWS. O PROVIDE NEW RUBBER FLOORING: THR000HOUT FITNESS AREA. CENTER RELOCATED WINDOWS IN WALL I• M 1N I NDON TYFES ALI SCALE:1/4'*'-0" 5F A INFILL NOTE5 I. TERMINATE AND. GAP ALL GAS, ELECTRIC, WATER AND DRAIN LINES; SPA OVERFLOW TRENDES AND HVAG SYSTEM DUCTWORK AS APPROPRIATE. 2. FILL SPA DRAIN LINES AND OVERFLOW OUTLETS WITH HYDRO CEMENT. 5. SAWGUT AND REMOVE PRECAST CONCRETE PERIMETER COPING 4. REMOVE SPA WALL TO ONE FOOT BELOW NEW FINISHED FLOOR ELEVATION TO ALLOW CRUSHED STONE INFILL UNDER SLAB. Robert Evenson Associates A A T : A Architecture Planning Interior Space Planning 6249 SW Canyon Court Portland, Oregon 97221 503-221=0890 ' S. INSTALL 12" PEA STONE ABOVE SPA FLOOR SLAB. 6. INSTALL FILTER FABRIC (MARAFI 140) ABOVE CRUSHED STONE. �► jr 500 Washington Avenue South, Suite 3000 lvl Minneapoils, MN 56415 -1. INSTALL GAS CRUSHED STONE (APPROX. 2T PER CY) — BUS: (612)395-7060:'Fax: (612)395-7002 DEVELOPING REAL ESTATE FOR PEOPLE, COMPACTED TO 410% TO 6" BELOW FINISHED FLOOR BvslNEss & COMMUNITIES. SURFACE. 6. INSTALL 6 MIL. VAPOR BARRIER OVER COMPACTED ' �e g i .e .t r'd t i an PILL. a. INSTALL 16" LONG #4 REBAR DOWELS AT 4'-0" O.G. AT PERIMETER OF SPA (MIN..2 INTO CONCRETE FLOOR SLAB) .i 10. INSTALL 6X6 10/10 MF IN SLAB 11. INSTALL 4" - 3000# LIGHTWEIGHT- CONCRETE FLOOR SLAB WITH FLOAT FINISH. 12. LEVEL FULL FLOOR, INGLUDIN6 ADJACENT SLOPED Date: Reg. No.: A"tON WITH SELF LEVELING UNDER-LAYMENT (LEVELA5TIC) TO FINAL FFE. READY TO ACCEPT Drawn By: JASON 6RUHN FLOORING. Checked By: JOHN FERRIER OF, Project. Manager: ROBB &ULNER GQr�.� Date: JULY 25, 2014 _.., n R a v I a I o n s I. GENERAL CONTRACTOR 15 TO COORDINATE ALL TRADES FOR THEIR REQUIRED DEMOLITION WORK. 2. DASHED LINES INDICATE WALL5, DOORS AND OTHER ITEMS TO BE REMOVED, UNLESS NOTED OTHERWISE.. 5. WHERE PARTITION WALLS ARE INDICATED TO BE REMOVED, REMOVE WALL AND ALL ITEMS THAT ARE ON OR WITHIN THAT WALL UNLE55 NOTED OTHERWISE. THIS INCLUDES DOORS, FRAMES, HARDWARE, AND MECHANICAL AND ELECTRICAL EQUIPMENT. 4. PATCH AND REPAIR ALL EXISTING CEILING5, PARTITIONS, AND FLOORS DISTURBED FOR NEW WORK AND FINISH. 5. PROTECT EXISTING FIRE ALARM DEVICES, HORN, AND STROBES DURING DEMOLITION AND CONSTRUCTION ACTIVITY. RELOCATE EXISTING AS REQUIRED. 6. GENERAL CONTRACTOR TO VERIFY WALLS TO BE DEMOLISHED ARE NOT LOAD BEARING. 'I. MAINTAIN ADEQUATE STRUCTURAL SUPPORT, LIFE -SAFETY, SECURITY AND ALARMS FOR ALL ITEMS OR PARTS OF ITEMS WHICf I ARE TO REMAIN DURING CONSTRUCTION. & REMOVE FROM 51TE AS SOON AS PRACTICABLE DEMOL15HED MATERIALS,' DEBRIS, AND RUBBISH. DO' NOT ACCUMULATE DEBRIS ON THE FLOOR OR AT THE SITE. al. PATCH AND REPAIR HOLE5 IN EXISTINGG. PYP°BD PARTITIONS AFTER REMOVAL OF EoUUIPMENT, MECHANICAL AND ELECTRICAL' DEMCE5 AND OUTLETS, ATTACHMENTS, FURNISHINGS, ETC. 10. CAP ALL PLUMBING IN SPA AS REQUIRED. PEMOL I TION PLAN Di REMOVE WALL AND ALL ASSOCIATED. ITEMS WITHIN THAT WALL. SALVAGE EXISTING WINDOWS FOR RELOCATION. ® DEMO EXISTING SPA AND ALL ASSOCIATED ITEMS.'GAP ALL. PLUMBING AS REGUIRED.- <19> DEMO EXISTING COPING AROUND SPA AREA. PREPARE AREA FOR NEW FLOOR FINISH. <6> DEMO GYP. BOARD CEILING AND CAN LIGHITING IN THIS AREA (SPA). PREPARE' CEILING FOR NEW LAY IN CEILING. TIE INTO EXISTING. IA �EV���D �OFi �� p \!�D DE AP APR 14 2015 City of Tukwila BUILDING DIVISION BAR &. SPA REMODEL SEATAC .COURTYARD TUKKLA, NA5 1 N6TON PERMIT SET 03-20-2015 Robert Evenson Associates 'Architects AIA Architecture Planning Interior Space Planning 6249 SW Canyon Court Portland, Oregon 97221. 503-221-0890 s-csm 500 Washington' Avenue South, Sul43000Minneapolis, MN 55415 Bus: (612) 395.7000 Fax: (612) 395.7002 DEVELOPING REAL ESTATE FOR PEOPLE, BUSINESS & COMMUNITIES .Rog istr.atIo.n.:. Dote: Res No.: Drawn By: JASON GRUHN checked By: JOHN FERRIER POOL 102 BAR - WALE-. 3/16"=1t-O" Oi REUSE EXISTING 20A CIRCUIT FROM SPA FOR NEW WALL OUTLETS. O REUSE EXISTING 2OA-CIRCUIT FROM POOL FOR NEW FLOOR MOUNTED OUTLETS. ELEGTRIGAL KEY GENERAL NOTES I. ALL OUTLETS TO BE 12OV. UNLE55 OTHERWI5E NOTED. 2. CENTER OF OUTLETS TO BEAT la" A.F.F. UNLESS OTHERWISE NOTED. 5. CONTRACTOR TO REVIEW OUTLET AND POWER LOCATION/REOUIREMENT WITH TENANT. 4. ELECTRICAL CONTRACTOR TO CLEARLY MARK CIRCUITS'AND V/D PORTS BACK TO MECHANICAL ROOM AND NETWORK ROOM. S. . EXACT LOCATIONS OF ELECTRICAL AND DATA OUTLETS. ARE TO BE VERIFIED WITH TENANT AND COORDINATED WITH ELECTRICAL DESIGN/BUILD SUBCONTRACTOR: 6. FURNITURE VENDOR TO COORDINATE WITH TENANT POWER REQUIREMENTS. RIB CODE COMP EVWEULIP+N E APpRoVED APR City of-Tulwvl BUILDING D SiC)1� MATERIAL 50HEDULE KEY MATERIAL DESCRIPTION LOCATION VWC-1 VINYL WALLCOVERING ' MAR .145 CITRUS FITNESS ROOM OWNER - TO SITE VWG-2 VINYL WALLCOVERING EXISTING ON SITE BAR / LOUNGE ON SITE VWG-5 VINYL WALLGOVERING .FULTON FITNESS ROOM OWNER TO SITE PT-1 PAINT MATCH fXISTiNG POOL G.G. CTB-I CERAMIC TILE EXISTING - MATCH FLOOR` BAR`- BASE... -:'ON SITE AB-1 WOOD BASE EXISTING LOUNGE - BASE G.G. RB-I RUBBER FLOORING TUFF`ROLL - 6MM GREY FITNESS ROOM - FLOORING 670 S.F. OWNER - TO SITE ACT-1 ACOUSTICAL CEILING TILES FITNE55 ROOM G.G. WO-1 WOOD GAP MATCH EXISTING CHERRY BAR / LOUNGE G.G. T 500 Washington Avenue South, Suite 3000 c S 1\1�/11 Minneapolis, MN 55415 Bus: (612)395.7000 Fax: (612)395.7002 DEVELOPING REAL ESTATE FOR PEOPLE, BUSINESS & COMMUNITIES RegistratIah Date: Reg. No.: Drawn By: JA50N 6RUHN . Checked By: JOHN FERRIER Project. Manager:: ROBB 6ULNER`•