Loading...
HomeMy WebLinkAboutPermit D15-0099 - FIRST CHOICE - GARAGEFIRST CHOICE 4471S134 TH PL EXPIRED D15-0099 City of Tukwila (DPhone: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.Tukwi[aWA.eov DEVELOPMENT PERMIT Parcel No: 2613200084 Permit Number: D15-0099 Address: 4471 S 134TH PL BLDG C Issue Date: 6/5/2015 Permit Expires On: 12/2/2015 Project Name: FIRST CHOICE Owner: Name: NORTH STREAM DEVELOPMENT Address: 720 4TH AVE STE 102, KIRKLAND, WA, 98033 Contact Person: Name: JAN GREENS Phone: (253) 893-1156 Address: 631 STRANDER BLVD, STE 860, TUKWILA, WA, 98188 Contractor: Name: CRESSY DOOR Phone: Address: PO BOX 55549, SHORELINE, WA, 98155 License No: Expiration Date: Lender: Name: Address: DESCRIPTION OF WORK: CHANGE EXISTING GARAGE FROM 9' X 9' TO 14' TALL X 9' WIDE. CUT OUT 5'-0" OF CONCRETE PANEL ABOVE EXISTING OPENING AND REINFORCE WITH STEEL CHANNEL. Project Valuation: $7,600.00 Fees Collected: $424.58 Type of Fire Protection: Sprinklers: Fire Alarm: NO Type of Construction: VB Occupancy per IBC: S-2 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: 125 Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE ` Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature Date: rl I hearby certify that I have read and examined this pip6t and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating cons ucti r the performance of work. I am authorized to sign and obtain this development permit anti agr a cc ditions attached to this permit. Signature: Print Name: r Date: �4 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 4046 SI-EPDXY/EXP CONC 4004 SI-WELDING CITY OF TM, .LA Community Development Department '* Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, %V'A 98188 Lftp://www.TukwilaWA.gov SITE LOCATION Building Permit No. j%M Project No. Date Application Accepted: 5 Date Application Expires: (! or office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. RECEIVED Applications will not be accepted through the mail or by fax. CITY OF T.V K WILA "Please Print" King Co Assessor's Tax No.: Site Address: f47/ S 13gH PG Suite Number: /3La9lrr � G.r Floor: I or Tenant Name: �/�STGH"O/L� New Tenant: Q..... Yes 2..No PROPERTY OWNER Name: _.... _ Address City: CONTACT PERSON - person receiving all project communication Name: 3�-Q (S. Address- 3t 5�-�SirL V Su Ci Zip Stated W. Phone2Z Fax. C7 2-1 Email: GENERAL CONTRACTOR INFORMATION dress: Z r7 , '2-72-ZNb `JT F City: _ Stated Zip- Phone: Z- . Fax: 10S 3 Contr Reg No.: -, Exp Date: t Tukwila Business License No. :1 - ARCHITECT OF RECORD Company Name: N Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: GT !rlvlt�b7Zt/✓!� Engineer Name: C�rt�et,�S T �a�iS Address: /g. Nl�/J ,�T s v/fig 3v z City: 50rTGE State: z.R Zip: 98log Phone: ZC&. Zg5 _#S-1 Z Fax. Email: Cham6C, Ge /N LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: H:Wpplications\Forms-Applications On Line'Q012 ApplicationAPermit Application Revised - 2-7-12 doc Revised: February 2012 Page I of 4 BUILDING PERMIT INFORMATIC 206-431-3670 Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Describe the scope of work (please provide detailed information): C fi/+1/Gs / 9Tii✓G / �c� G��!'�1 �I ` ?� 9' -'D ler t rA-u. x of !ti / me, ca 7- pv r S "O � 6G Gd1l G�GT� �/�j✓EL A-�oy6 G' �iTl�'C� 010�pv/NC• 00-11/p 2F1ffr-V 1e6 N' l rp a MCRI G/fi4-N/✓SL, Will there be new rack storage? ❑ .... Yes ,�o If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC IType of Occupancy per IBC ls` Floor 2 "d Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: — Will there be a change in use? ❑ ....... Yes Compact: Handicap: ❑ ....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ ....... Sprinklers ❑ ....... Automatic Fire Alarm /.. None ❑....... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .......Yes ❑ ...... No If "yes', attach list of materials and storage locations on a separate 8-112" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ .......On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. HAApplicationsWorms-Applications On Line\.0; 2 AppkaftnsTermit Application Revised - 2-7-12 doex Revised: February 20)2 Page 2 of 4 PUBLIC WORKS PERMIT INFO IATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ... Water District # 125 ❑... Highline El ... Renton ❑ .. Water Availability Provided C� Sewer District /) ❑ .. Tukwila ❑ ...Valley View ❑... Renton ❑... Seattle ❑ .. Sewer Use Certificate ❑ ...Sewer Availability Provided Septic System: ❑ On -site Septic System —For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application finark boxes which nor ❑ - Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑... Geotechnical Report El.. Traffic Impact Analysis ❑ .. Bond ❑... insurance ❑... Easement(s) ❑... Maintenance Agreement(s) ❑ .. Hold Harmless — (SAO) El.. Hold Harmless — (ROW) Proposed Activities (mirk boxes that imply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑... Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑... Right-of-way Use — Potential Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ .. Total Cut cubic yards ❑ ..Total Fill u cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water El ... Work in Flood Zone El ... Storm Drainage El ... Abandon Septic Tank ❑... Curb Cut ❑... Pavement Cut ❑... Looped Fire Line El ... Grease Interceptor El ... Channelization ❑... Trench Excavation ❑... Utility Undergrounding ❑ .. Permanent Water Meter Size (1) WO # (2) WO # (3) WO # ❑ .. Temporary Water Meter Size (1) WO # (2) WO # (3) WO # ❑ .. Water Only Meter Size ........... _ " Wo # ❑ .. Deduct Water Meter Size " ❑ .. Sewer Main Extension............ Public ❑ ❑ Private ❑ .. Water Main Extension............ Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billine: Name: Mailing Address: Day Telephone: City State Zip H:\Applications\Forms-Applications On Line\2012 ApplicationsTurnit Application, Revised - 2.7-12 docx Revised: Febiary 2012 Page 3 of 4 PERMIT APPLICATION NOTES — ' Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. OR AUTHORIZAD jKGENT: Print Mailing Address: Date: Day Telephone: State Zip Fi:\Applications\Forms-Applicaiinns On Une\2012 ApphcaliansTermit Application Revised - 2.7-12 docx Revised: Febmary 2012 Page 4 of 4 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $424.58 D15-0099 Address: 4471 S 134TH PL BLDG C Apn: 2613200084 $424.58 DEVELOPMENT $412.22 PERMIT FEE R000.322.100.00.00 0.00 $247.10 PLAN CHECK FEE R000.345.830.00.00 0.00 $160.62 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $12.36 TECHNOLOGY FEE TOTAL1 R000.322.900.04.00 0.00 $12.36 Date Paid: Monday, May 04, 2015 Paid By: KIDDER MATHEWS Pay Method: CREDIT CARD 030729 Printed: Monday, May 04, 2015 12:34 PM 1 of 1 p?WSY57EM5 OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing 6747 M. L. King Way South, Seattle, Washington 98118-3216 USA Tel: (206) 725-4600 • Toll Free: (888) OTTO-4-US • Fax: (206) 723-2221 WBE W2F5913684 • WABO Registered Agency • Website: www.ottorosenau.com August 3, 2015 Recetv SEP - i FINAL REPORT -t 2v1 City of Tukwila 6300 So thcen erlB Blvd, Suite 100 ing Department poo� pme� Tukwila, Washington 98188-2544 Project: First Choice Address: 4471 S. 134`h Place, Tukwila Permit Number: D15-0099 Job Number: 15-0496 We state that the work requiring special inspection was, to the best of our knowledge, in conformance with the approved plans and specifications and the applicable workmanship provision of the building code. Our knowledge is limited to our reports. All typewritten reports have been mailed to your office or are enclosed. All reports appear to be complete. This report should not be considered as a warranty for conditions and/or details of the building. Items inspected are: 1. Mechanical anchor bolt installation 2. Structural steel erection Sincerely, OTTO ROSENAU & ASSOCIATES, INC. Crista Moser Report Manager - r* C 180 Nickerson St. INC. FILE 777 Suite 302 Seattle, WA 98109 (206)285-4512(V) (206) 285-0618(F) STRUCTURAL CALCULATIONS Expand Door Opening in Existing Tilt Up Building First Choice Fostoria Park Building C 4471 S 1341h Place Tukwila, WA Structural Engineers 'FtEVtWED FOR CODE COMPLIANCE APPROVED MAY 18 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 0 4 2015 PERMIT CENTER N DI5•p0%�1 '-,,jj .1271 Z(v INC. Project: Gt CKe/-11F, — 1101+;eli Date: Client Page Number: o Gosr��r ��n � �"k/�!�i/1� I�ravi2.. a/lo�v,M�► � �� �/G,fir/<.r PtYNEUS. + z21= IZt" 6*L- �Ivv p �'i��r✓S - / N y �vt� tt / v � !?� / h� . d �07rI r�lYy o � NO eit'171W/V - W = �Zj '+I"T IAS�, 2t7(� +����C ► Sb sb21a iota _� � � 13 , �i.s' `k, / mil% � l� �Tb?v H� /3GJLe'i`S• . e, b� 115' 180 Nickerson St, Suite 302 Seattle, WA 98109 (206)285-4512 PAX: (206)285-0618 Structural Engineers s I C T INC. Project: 'O/eSr''M--Vee Client: �p - &4^ 1"aP S� W� i 180 Nickerson St. Suite 302 Seattle, WA 2�y/20/ s 98109 Date: (206)285-9512 PAX: 1'af a Number (206) 285-0618 l�►�L = 5ro Apo Oo Structural Enaineers Title Block Line 1 Project Title: Yid can change this area En ineer: Project ID: using the "Settings" menu item Pro�ect Descr: and then using the "Printing & Title Block" selection. Title Block Line 6 Printed: 3 FEB 2015. 9:24AM File = r.115023 Fostoria Park - TukwilaVostoda.ec6 Steel BeamENERCA LC, INC. 1963.2015,Bulld:6,15.1.19,Ver.6.14.6.31 Description : beam at top of opening _CODE REFERENCES Calculations per AISC 360-10, IBC 2012, ASCE 7-10 Load Combination Set: ASCE 7-10 Material Properties Analysis Method: Allowable Strength Design Beam Bracing: Completely Unbraced Bending Axis: Major Axis Bending Load Combination ASCE 7-10 D 0.77 S 0.25 Span =10.0 ft MUM Fy : Steel Yield: 50.0 ksl E: Modulus: 29,000.0 ksi Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weiqht calculated and added to loadinq Uniform Load : D = 0.770, S = 0.250 k/ft, Tributary Width =1.0 ft DESIGN SUMMARY ' Maximum Bending Stress Ratio = 6.861 : 1 Maximum Shear Stress Ratio = 0.119 : 1 Section used for this span C8x13.75 Section used for this span C8x13.75 Ma: Applied 12.922 k-ft Va : Applied 5.169 k Mn / Omega: Allowable 15.011 k-ft Vn/Omega : Allowable 43.545 k Load Combination +D+S+H Load Combination +D+S+H Location of maximum on span 5.000ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.054 in Ratio = 2,215 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.224 in Ratio = 536 Max Upward Total Deflection 0.000 in Ratio = 0 <240 Maximum Forces& Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Me - Max Mnx Mnx10mega Cb Rm Va Max Vnx Vnx/Omega +D+H Dsgn. L = 10.00 ft 1 0.653 0.090 9.80 9.80 25.07 15.01 1.14 1.00 3.92 72.72 43.54 +D+L+H Dsgn. L = 10.00 ft 1 0.653 0.090 9.80 9.80 25.07 15.01 1.14 1.00 3.92 72.72 43.54 +D+Lr+H Dsgn. L = 10.00 ft 1 0.653 0.090 9.80 9.80 25.07 15.01 1.14 1.00 3.92 72.72 43.54 +D+S+H Dsgn. L = 10.00 ft 1 0.861 0.119 12.92 12.92 25.07 15.01 1.14 1.00 5.17 72.72 43.54 +D+0.7501-r+0.7501-+1­1 Dsgn. L = 10,00 ft 1 0.653 0.090 9.80 9,80 25.07 15.01 1.14 1.00 3.92 72.72 43.54 +D+0.750L+0.750S+H Dsgn. L = 10.00 ft 1 0.809 0.112 12.14 12.14 25.07 15.01 1.14 1.00 4.86 72.72 43.54 +D+0.60W+H Dsgn. L = 10.00 ft 1 0.653 0.090 9.80 9.80 25.07 15.01 1.14 1.00 3.92 72.72 43.54 +D+0.70E+H Dsgn. L = 10.00 ft 1 0.653 0.090 9.80 9.80 25.07 15,01 1.14 1.00 3.92 72.72 43.54 +D+0.750 L r+0.750 L+0.450 W+H Dsgn, L = 10.00 ft 1 0.653 0.090 9.80 9.80 25.07 15.01 1.14 1.00 3.92 72.72 43.54 +D+0.750L+0.750S+0.450W+H Dsgn. L = 10.00 ft 1 0.809 0.112 12.14 12.14 25.07 15.01 1.14 1.00 4.86 72.72 43.54 +D+0, 750 L+0.750 S+0.5250 E+H Dsgn. L = 10.00 ft 1 0.809 0.112 12.14 12.14 25.07 15.01 1.14 1.00 4.86 72.72 43.54 +0,60D+0.60W+0.60H Dsgn. L = 10.00 ft 1 0.392 0.054 5.88 5.88 25.07 15.01 1.14 1.00 2.35 72.72 43.54 T he Block Line 1 Project Title; ' i ou can change this area En sneer: Project ID. using the "Settings" menu item Pro�ect Descr; and then using the "Printing & Title Block" selection, Title Block Line 6 NOW: 3 FEB 2015, 9:24AM He = r:116023 Fostoria Park-TukwilaVostoria.ec6 Steel Beam ENERCALC, INC. 1983.2015,Bulld:6.15.1.19,Vec6.14.5,31 Description : beam at top of opening Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega +0.60D+0.70E+0.60H Dsgn, L = 10.00 ft 1 0.392 0,054 5.88 5.88 25.07 15.01 1.14 1.00 2.35 72.72 43.54 Overall Maximum Deflections Load Combination Span Max. "" Deft Location in Span Load Combination Max. "+" Deft Location In Span +D+S+H 1 0.2240 5.050 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 5.169 5.169 Overall MINimum 1.250 1.250 +D+H 3.919 3.919 +D+L+H 3.919 3.919 +D+Lr+H 3.919 3.919 +D+S+H 5.169 5,169 +D+0.750Lr+0.750L+H 3.919 3.919 +D+0.750L40.750S+H 4,856 4.856 +D+0.60W+H 3.919 3.919 +D+0.70E+H 3.919 3.919 +D+0.750Lr+0,750L+0.450W+H 3.919 3.919 +0+0.750L+0.750S+0.450W+H 4.856 4.856 +D+0.750L+0.750S+0.5250E+H 4,856 4.856 +0.60D+0.60W+0.60H 2.351 2.351 +0,60D+0.70E+0.60H 2.351 2.351 D Only 3.919 3.919 Lr Only L Only S Only 1.250 1.250 W Only E Only H Only Bite Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Steel Column Description : strongback Code References Calculations per AISC 360-10, IBC 2012, CBC 2013, ASCE 7-10 Load Combinations Used : ASCE 7-10 General Information Project Title: En in eer: Proect Descr: File = Project ID: Printed: 3 FEB 2015, 9:37AM 'ark - Tukwilalfostoda.ec6 d:6.15.1.19, Ver:6.14.5,31 Steel Section Name: HSS5x2-112x1/4 Overall Column Height 22.0 ft Analysis Method: Allowable Strength Top & Bottom Fixity Top & Bottom Pinned Steel Stress Grade Brace condition for deflection (buckling) along columns: Fy : Steel Yield 42.0 ksi X-X (width) axis: E : Elastic Bending Modulus 29,000.0 ksi Fully braced against buckling along X-X Axis Load Combination : ASCE 7-10 Y-Y (depth) axis: Fully braced against buckling along Y-Y Axis Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weight included : 249.262 Ibs " Dead Load Factor BENDING LOADS , . . Lat, Uniform Load creating Mx-x, W = 0.2250 k/ft Lat. Uniform Load from 0.0-->14,0 ft creating Mx-x, E = 0.0850 k/ft Lat. Uniform Load from 12.0-->22.0 ft creating Mx-x, E = 0.350 k/ft DESIGN SUMMARY Bending & Shear Check Results PASS Max, Axial+Bending Stress Ratio = 0.9390 :1 . Maximum SERVICE Load Reactions - Load Combination Load +D+0.70E+H Top along X-X 0.0 k Location of max,above base 13,289 ft Bottom along X-X 0.0 k At maximum location values are ... Top along Y-Y 3.083 k Pa: Axial 0.2493 k Bottom along Y-Y 2.475 k Pn / Omega: Allowable 78.970 k Ma-x : Applied 9.490 k-ft Maximum SERVICE Load Deflections ... Mn-x / Omega: Allowable 10.123 k-ft Along Y-Y 4.397 in at 11.074ft above base for load combination: W Only Ma-y :Applied 0.0 k-ft Mn-y / Omega: Allowable 6.183 k-ft Along X-X 0.0 in at O.Oft above base for load combination PASS Maximum Shear Stress Ratio = 0.07136 :1 Load Combination +D+0.70E+H Location of max.above base 22.0 ft At maximum location values are ... Va : Applied 2.158 k Vn / Omega: Allowable 30.244 k Load Combination Results Load Combination Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Stress Ratio Status Location Stress Ratio Status Location +D+H 0.003 PASS 0.00 ft 0.000 PASS 0.00 ft +D+L+H 0.003 PASS 0.00 ft 0.000 PASS 0.00 ft +D+Lr+H 0.003 PASS 0.00 ft 0.000 PASS 0.00 ft +D+S+H 0.003 PASS 0.00 ft 0.000 PASS 0.00 ft +D+0.750Lr+0.750L+H 0.003 PASS 0.00 ft 0.000 PASS 0.00 ft +D+0.750L+0.750S+H 0.003 PASS 0.00 ft 0.000 PASS 0.00 It +D+0.60W+H 0.808 PASS 11.07 ft 0.049 PASS 0.00 ft +D+0.70E+H 0.939 PASS 13.29 ft 0.071 PASS 22.00 ft +D+0.750Lr+0.750L+0.450W+H 0.607 PASS 10.93 ft 0.037 PASS 0.00 ft +D+0.750L+0,750S+0,450W+H 0.607 PASS 10.93 ft 0.037 PASS 0.00 ft +D+0.750L+0.750S+0.5250E+H 0.705 PASS 13.29 ft 0.054 PASS 22.00 ft +0,60D+0.60W+0.60H 0.808 PASS 11.07 ft 0.049 PASS 0.00 ft +0,60D+0.70E+0.60H 0.938 PASS 13.29 ft 0.071 PASS 22.00 ft Title Block Line 1 IAu can change this area using the "Setiings" menu item and then using the "Printing & Title Block" selection, Steel Column Description : strongback Maximum Reactions Load Combination Project Title: Engineer: Project Descr: X-X Axis Reaction Y-Y Axis Reaction @ Base @ Top @ Base @ Top Project ID: Printed: 3 FEB 2015, 9:37AM File = rM5023 Fostoria Perk - TukwllaVbstode.ec6 RCALC, INC.1963-2015, Bulld:6.161.%Ver:6.14,6.31 Note: Only non -zero reactions are listed. Axial Reaction @ Base +D+H k k U24V K +D+L+H k k 0,249 k +D+Lr+H k k 0.249 k +D+S+H k k 0.249 k +D+0.750Lr+0.750L+H k k 0.249 k +D+0.750L+0,750S+H k k 0.249 k +D+0.60W+H k -1,485 1.485 k 0,249 k +D+0,70E+H k -1.125 2.158 k 0.249 k +D+0,750Lr+0,750L+0.450W+H k -1.114 1,114 k 0.249 k +D+0.750L+0.750S+0.450W+H k -1.114 1.114 k 0,249 k +D+0.750L+0,750S+0,5250E+H k -0.844 1.619 k 0.249 k +0.60D+0,60W+0.60H k -1.485 1.485 k 0.150 k +0.60D+0.70E+0.60H k -1.125 2.158 k 0.150 k D Only k k 0.249 k Lr Only k k k L Only k k k S Only k k k W Only k -2.475 2.475 k k E Only k -1.607 3.083 k k H Only k k k Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance +D+H 0.0000 in 0.000 ft 0.000 in 0.000 It +D+L+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+Lr+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+S+H 0.0000 in 0.000 It 0.000 in 0.000 ft +D+0.750Lr+0.750L+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.750L+0.750S+H 0.0000 in 0.000 It 0.000 in 0.000 It +D+0.60W+H 0.0000 in 0,000 ft 2.638 in 11.074 ft +D+0.70E+H 0.0000 in 0.000 it 2.881 In 11.664 It +D+0.750Lr+0.750L+0.450W+H 0.0000 in 0.000 ft 1.979 in 11.074 ft +D+0,750L+0.750S+0.450W+H 0.0000 in 0,000 ft 1,979 in 11.074 ft +D+0.750L+0.750S+0.5250E+H 0.0000 in 0.000 ft 2.161 in 11.664 ft +0.60D+0.60W+0.60H 0.0000 in 0.000 ft 2.638 in 11.074 ft +0.60D-470E4601-1 0.0000 in 0.000 ft 2.881 in 11.664 ft D Only 0.0000 in 0.000 ft 0.000 In 0.000 ft Lr Only 0.0000 in 0.000 ft 0.000 in 0.000 ft L Only 0.0000 in 0.000 ft 0,000 In 0.000 ft S Only 0.0000 in 0.000 It 0.000 in 0.000 ft W Only 0.0000 in 0.000 ft 4.397 in 11.074 ft E Only 0.0000 in 0.000 It 4,116 in 11.664 ft H Only 0.0000 in 0.000 ft 0,000 in 0.000 It Steel Section Properties : HSS5x2.112x114 Tale Block Line 1 Project Title: You can change this area En ineer: Project ID: using the "Settings" menu item Pro�ect Descr: and then using the "Printing & Title Block" selection, Title Block Line 6 Printed: 3 FED 2015, 9:37AM He = r.115023 Fostoria Park- TukwllaVbslorla,ec6 Steel Column ENERCALC.INC. 1983-2015.Build:6.15.1.19.Ver.6.14.5,31. Description : strongback Steel Section Properties : HSS5x2-112x114 Depth = 5.000 in I xx = 9.40 InA4 J = 7.930 InA4 S xx = 3,76 In"3 Cw = 4.99 inA6 Width = 2.500 in R xx = 1.730 In Wall Thick = 0.250 in Zx = 4.830 inA3 Area = 3.140 inA2 1 yy = 3.130 in"4 C = 4,990 In^3 Weight = 11.330 plf S yy = 2.500 in^3 R yy = 0,999 in Zy = 2.950In"3 Ycg = 0.000 in M-x Loads N "SNI II L Loads are total entered value. Arrows do not reflect absolute direction. ` Anchor Designer TM }�'I Software t'�Y Version 2.3.5365.7 au 1.Proiect Information Customer company: Customer contact name: Customer e-mail: Comment: 2. Input Data & Anchor Parameters General Design method:ACI 318-11 Units: Imperial units Anchor Information: Anchor type: Concrete screw Material: Carbon Steel Diameter (inch): 0.625 Nominal Embedment depth (inch): 4.000 Effective Embedment depth, her (inch): 2.970 Code report: ICC-ES ESR-2713 Anchor category: 1 Anchor ductility: No hmrn (inch): 6.00 cac (inch): 4.50 Cmrn (inch): 1.75 Smrn (inch): 3.00 Load and Geometry Load factor source: ACI 318 Section 9.2 Load combination: not set Seismic design: No Anchors subjected to sustained tension: Not applicable Apply entire shear load at front row: No Company: Date: 2/312015 Engineer: Page: 1 /4 Project: Address: Phone: E-mail: Anchors only resisting wind and/or seismic loads: No Z <Figure 1> 490 lb Project description: canopy supports Location: Fastening description: Base Material Concrete: Normal -weight Concrete thickness, h (inch): 6.00 State: Cracked Compressive strength, fc (psi): 4000 LP..v: 1.0 Reinforcement condition: A tension, A shear Supplemental reinforcement: Not applicable Do not evaluate concrete breakout in tension: No Do not evaluate concrete breakout in shear: No Ignore 6do requirement: Not applicable Build-up grout pad: No Base Plate Length x Width x Thickness (inch): 4.00 x 12.00 x 0.50 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines imust be checked for plausibility. Simpson Strong-Ti., !', ,: n; „ !: - . 5955 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Design Maps Summary Report Page 1 of 2 ELMS Design Maps Summary Report User -Specified Input Report Title Fosteria Tue February 3, 2015 17:27:27 UTC Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available In 2008) Site Coordinates 47.48°N, 122.281W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III 51111 r1�1 I ' Ii ' :I I: Vashon a. mapquest USGS-Provided Output Ss = 1.492 g S, = 0.559 g 'I I� �00, � EASE lientl �� _ HlgNlands itQtl `. B �l S,, = 1.492 g Sos = 0.995 g Sm, = 0.838 g Sol = 0.559 g @ MapQuest.. For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCC, lesponse Spectrum 1.ss 1.50 1,3 1.Z0 - 1.05 0.90 [A 0.75 0.r,0 0`5 T 0.30 gp 0.15 0.00-1 O.Oo 0.2o n �ip rt cn -] 69 1 OU 1.'20 1.Ao 1.co L.So z.00 1,04!rifod, r (srsc) Design Response Spectrum 1.10 1.Oo 0-90 OM 0.70 Q� 0.60 to 0_50 0.4p 0. 3o 0.20 0.10 0.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.0 1.90 2.00 Perlod. T (gecl 1,�-t,•,•//Al„•,1 ...o�,-th.,,,�1.�..., „��.�(.,,.,/ranoirt,�n�o,�olne/�m•nmarc� r,l•�r�7tan�r�lafa-minimalR��atifiu� 7/'�/7(11 5 C T 180 Nickerson St. Suite 302 � ��/ZGJr' Gf{TJ/L� G. Seattle, WA Project: Date: Z�Z Z!i/ S 98109 (206)285-4512 Client: rAX: Page Number: (2061 2as.nAi a t C T 1 N 0. Project: �ll�iJD�2/If ��fujT Gf{v/L� Client: A/AW N-4 S CX,?k/a 57-A w1/.. Date: Z� Page Number: Zvi S Olt il0/J B rLe)j'o4'✓ GLr*I/JCS Oxwo i //JS/Vd m O.di; /ye l N _ / ,t 180 Nickerson St. Suite 302 Seattle, WA 98109 (206)285-4512 FAX: (206)285-0618 Structural Engineers INC. Project: ,ot:2%)5ro&/A— r/ A S% e lA914!'��C Date: Client: .. !-ems rye ram+ sip$ zf ZIZo/s Page Number: 180 Nickerson St. Sulte 302 Seattle, WA 98109 (206) 285-4512 FAX: (206)285-0618 T/ r-&7Q AV s. M '6W1 VP1 STnrive, P3�v, to ` A&C eavlve-e-noiJ . ♦ � T7oN i Structural Engineers 180 Nickerson St. A C T Suite 302 Seattle, WA cos_.5r' G oic c� 41) Zap 206) ( 8109 Project: Date: 20G) 2854512 PAX: Client: Page Number: (206) 285.0618 i nralff/05-,�„�a gig. �11 GatVL r-1.b0 9 -- ) nb ��aa12 GaiJi►�G2TJr�N 3-r RtAx rh 47mvm - fiyrj'+'1 et34 �=� _ �& e,0 2-, R7V4#VrL .130t-13 151,4- ;r7nmf IS m w m tea yr = ,al ca1c rx*,T-rv7e.- rno owwr /j,#T" >io 'ova>L ewr ll ,o Vv" WA 00 6W Aw S ee*r1 owil 0?21 Strurtural Engineers of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 2/2/2016 JAN GREENS 631 STRANDER BLVD, STE 860 TUKWILA, WA 98188 RE: Permit No. D15-0099 FIRST CHOICE 4471 S 134TH PL Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 3/14/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 3/14/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 0" ,�1�4 Rachelle Rip�ey Permit Technician File No: D15-0099 6300 Southcenter Boulevard Suite #100 0 Tukwila, Washington 98188 e Phone 206-431-3670 e Fax 206-431-3665 PERMIT COORD COP`, PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0099 PROJECT NAME: FIRST CHOICE SITE ADDRESS: 4471 S 134TH PL X Original Plan Submittal Response to Correction Letter # 1 DEPARTMENTS: As NG�-- Building Division .u4 ww �1� DATE: 05/04/15 Revision # before Permit Issued Revision # after Permit Issued Nhn kyp 0 Fire Prevention E3 cL 14 � g Plannin Division Public Works M Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 5/5/2015 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 6/2/2015 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 CRESSY DOOR CO INC Page 1 of 2 Home lnicio en Espanol Contact. Safety Washington State Department of Labor & Industries CRESSY DOOR CO INC Owner or tradesperson Principals WITTERS, RICHARD W FERRER, R GEORGE Doing business as CRESSY DOOR CO INC WA UBI No. 578 049 740 License Search L&I r A-Z Index Help Nly Secure l &l Claims & Insurance Workplace Rights Trades & Licensing PO BOX 55649 SHORELINE, WA98155-0549 206-632-0533 KING County Business type Corporation Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .......................................................................... Meets current requirements. License specialties GENERAL License no. CRESSDC370NT Effective — expiration 08/30/1963-11/25/2016 Bond ................ OLD REPUBLIC SURETY CO $12,000.00 Bond account no. YLI244969 Received by L&I Effective date 11/21/2007 01/01/2003 Expiration date Until Canceled Insurance ........................... Ohio Security Ins Co $1,000,000.00 Policy no. BKS55811544 Received by L&I Effective date 09/09/2014 09/12/2013 Expiration date 09/1212015 Insurance history Savngs ........i......... No savings accounts during the previous 6 year period. Lawsuits ag_ainstthe„bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No&tax de..b. ts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=578049740&LIC=CRESSDC37ONT&SAW= 6/1/2015 RE\&WED FOR )DE COMPLIANCE SCALE: 1*=60' RK BUILDING wC* i PL 98168 AREA OF WORK PLANTER BUILDING PLAN , 6' NEW C8x13.7 PANEL NEW SIMPSON TITEN-HD AT 24*OC EMBEDMENT 4* a. A SCALE: 3/4' = l'-O* vCL NEW OPENING TYPICAL CHANNEL ❑1 AT TOP OF OPENING MAY 18 2015 R OPIumbina n )nnn i GoogI� feet'wth Wu feet! No changes shall be made to the scope SCALE: Nllermit No. of ivork without prior approval of Iding Division. i n review approval is subject to enirs and o*%. PLAN r r,'-submittE!I oval of construction documents does not authorize -Q the violation of any ad ed or ordinance. Receipt of approved Field ditions, is acknowledged: R E I V E 0 By: CITY OF TUKWILA Date: MAY G 4 2015 City of Tukwila PERMIT CENTER 4VP BUILDING DIVISION I CT PROJECT NAME First Choice— Fostoria Park Bldg. "C" PROJECT NO. 15023 INC. Structural Engineers 4471 S 134th PI Tukwila, WA 98168 SCALE AS NOTED 180 Nickerson Street Suite 302 Seattle, WA 98109 206.285.4512 (V) 206.285.0618 (F) DATE 04/30/15 PACE: S1.0_ a _A. STRUCTURAL NOTES 01000: GENERAL REQUIREMENTS THE STRUCTURAL NOTES SUPPLEMENT THE PLANS AND SPECIFICATIONS. ANY DISCREPANCY FOUND BETWEEN THE -DRAWINGS, NOTES, SPECIFICATIONS, SITE CONDITIONS, AND ARCHITECTURAL PLANS SHALL BE REPORTED TO THE ARCHITECT WHO SHALL CORRECT THE DISCREPANCY IN WRITING. ANY WORK COMPLETED AFTER DISCOVERY OF THE DISCREPANCY SHALL BE DONE AT THE CONTRACTOR'S RISK. REFER TO ARCHITECTURAL PLANS FOR OPENINGS, ARCHITECTURAL TREATMENTS, AND DIMENSIONS NOT SHOWN. CONSULT MECHANICAL PLANS FOR DUCTS AND PIPES ETC. NOT SHOWN. THE CONTRACTOR SHALL PROVIDE BRACING AND SUPPORT REQUIRED FOR TEMPORARY CONSTRUCTION LOADS AND FOR STRUCTURAL COMPONENTS AS REQUIRED DURING ERECTION. BACKFILL BEHIND WALLS SHALL NOT BE PLACED UNTIL THE WALLS ARE PROPERLY SUPPORTED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL WORK. THE CONTRACTOR SHALL -BE RESPONSIBLE FOR THE COORDINATION OF THE EXCAVATION, SHORING, AND OTHER WORK WITH ALL UTILITIES AND ADJACENT PROPERTIES. CALL THE UTILITY LOCATE SERVICE PRIOR TO ANY WORK AT 1-800-424-5555. 01100: CODE REQUIREMENTS ALL DESIGN AND CONSTRUCTION SHALL CONFORM TO THE 2012 INTERNATIONAL BUILDING CODE AS ADOPTED BY THE CITY OF SEATTLE, WASHINGTON. 01200: DESIGN LOADS ROOF LIVE LOADS ROOF (SNOW) 25 PSF SNOW LOAD DESIGN DATA: Pg = 25 PSF, Pf = 16 PSF, Ce = 0.9, Is = 1.0, Ct = 1.0, WIND DESIGN DATA: BASIC WIND SPEED: WIND IMPORTANCE FACTOR: WIND EXPOSURE: TOPOGRAPHIC FACTOR INTERNAL PRESSURE COEFFICIENT: COMPONENT/CLADDING WIND PRESSURE: EARTHQUAKE DESIGN DATA: SEISMIC IMPORTANCE FACTOR: RICK CATEGORY: SPECTRAL RESPONSE ACCELERATIONS: SITE CLASS: SPECTRAL RESPONSE COEFFICIENTS SEISMIC DESIGN CATEGORY: I14 BASIC FORCE RESISTING SYSTEM: WOOD LEVELS ANALYSIS PROCEDURE: CT — MRINC. Structural Engineers 180 Nickerson Street Suite 302 Seattle, WA 98109 206.285.4512 (V) 206.285.0618 (F) 110 MPH (LRFD) (3—SECOND GUST) IW = 1.0 EXPOSURE B KT = 1.00 GCPI = +/— 0.18 P(C) = 40 PSF (LRFD) le = 1.0 Ss = 1.49 S1 = 0.56 SITE CLASS D SDS = 0.995 SD1 = 0.56 SEISMIC DESIGN CATEGORY D BEARING WALL SYSTEM EQUIVALENT LATERAL FORCE PROJECT NAME Iwo APPROVED MAY 18 2015 RAL STEEL DESIGN, SFABRI CAT ON, AND ERECTION OF STRU TURae44T(A IL�BE I N ACCORDANCE WITH THE LATEST EDITION OF THE G. GIO TEEL CONSTRUCTION "AISC SPECIFICATION FOR DESIGN, F I ,!�ECTION OF STRUCTURAL STEEL FOR BUILDINGS". MATERIALS SHALL BE IN ACCORDANCE WITH THE FOLLOWING: STRUCTURAL W SHAPES S, M, AND C SHAPES STEEL ANGLES PLATE MATERIAL STRUCTURAL PIPE STRUCTURAL TUBE HEADED STUDS WELDING ELECTRODES HIGH STRENGTH BOLTS ANCHOR BOLTS WOOD CONNECTION BOLTS ASTM A-992 Fy = 50 KSI ASTM A-36 Fy = 36 KSI ASTM A-36 Fy = 36 KSI ASTM A-36 Fy = 36 KSI ASTM A-53 GRADE B Fy = 35 KSI ASTM A-500 GRADE B Fy = 46 KSI ASTM A-108 E70—XX ASTM A-325N BEARING TYPE (SNUG TIGHT) ASTM A-307 OR ASTM A-36 ASTM A-307 ALL WELDING SHALL CONFORM TO THE AWS D1-1 "STRUCTURAL WELDING CODE". ALL WELDING SHALL BE PERFORMED BY A WASHINGTON ASSOCIATION OF BUILDING OFFICIALS (WABO) AND AMERICAN WELDING SOCIETY (AWS) CERTIFIED WELDERS. ALL COMPLETE PENETRATION (CP) WELDS SHALL BE ULTRASONICALLY TESTED. ALL FILLET WELDS SHALL BE VISUALLY INSPECTED. STRUCTURAL STEEL AND CONNECTIONS EXPOSED TO WEATHER SHALL BE HOT DIPPED GALVANIZED AFTER FABRICATION IN COMPLIANCE WITH ASTM A-123. ALL FIELD WELDS EXPOSED TO WEATHER SHALL BE COATED WITH BRUSH APPLIED ZINC —RICH PAINT COMPLYING WITH ASTM A-780. 03162: ADHESIVE ANCHORS IN CONCRETE ALL ADHESIVE ANCHORS SHALL BE ICC APPROVED AND INSTALLED PER ICC EVALUATION REPORT REQUIREMENTS. BOLT SPACING AND EMBEDMENTS SHALL BE AS DESIGNATED ON THE DRAWINGS TYPICAL, UNLESS NOTED OTHERWISE. ALL ADHESIVE ANCHORS SHALL BE INSTALLED WITH CONTINUOUS INSPECTION PER THE INSPECTION SCHEDULE ON SHEET S1.01, U.N.O.. ADHESIVE ANCHORS IN CONCRETE SHALL BE THE FOLLOWING TYPES OR A PREAPPROVED EQUAL; POWERS PURE 110+ (ICC ESR-3298) POWERS PE 1000+ (ICC ESR 2583) POWERS AC 100+ GOLD (ICC ESR-2582) BOLT SIZE MI NI MUM EFFECT VE EMBEDFj,,).0. 1/2" DIA. OR #4 REBAR 4" CITY OF TUJJKWILA ED 5/8" DIA. OR #5 REBAR 5" 3/4" DI A. OR #6 REBAR 6" MAY 0 4 2015 PERMIT CENTER First Choice— Fostoria Park Bldg. "C" PROJECT NO. 15023 4471 S 134th PI Tukwila, WA 98168 SCALE AS NOTED 04/30/15 1.,P4G-F,: _ � A ,,, S2,0