Loading...
HomeMy WebLinkAboutPermit D15-0118 - GEORGETOWN HOME & GARDEN - STORAGE RACKSGEORGETOWN HOME & GARDEN 1224 ANDOVER PARK E D15-0118 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: httr)://www.TukwilaWA.Rov DEVELOPMENT PERMIT Parcel No: 3523049071 Permit Number: D15-0118 Address: 1224 ANDOVER PARK E Issue Date: 6/15/2015 Permit Expires On: 12/12/2015 Project Name: GEORGETOWN HOME & GARDEN Owner: Name: KLEIN HARRIS Address: 5360 LANSDOWNE LN , MERCER ISLAND, WA, 98040 Contact Person: Name: CAREY FERGUSON Address: 500 SW 16 ST, RENTON, WA, 98057 Contractor: Name: MR RACKS LLC Address: 2415 S 242 ST , DES MOINES, WA, 98198 License No: MRRACRL24BN Lender: Name: GEORGETOWN HOME & GARDEN Address: 1224 ANDOVER PARK E , TUKWILA, WA, 98188 DESCRIPTION OF WORK: Phone: (253) 569-9765 Phone: (206) 383-9742 Expiration Date: 1/17/2016 INSTALL 73 SECTIONS OF CUSTOMER SUPPLIED PALLET STORAGE RACK. EACH SECTION IS 441, DEEP X 16, HIGH AND 8' WIDE WITH 2 AND 4 BEAM LEVELS Project Valuation: $8,881.00 Fees Collected: $457.90 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Occupancy per IBC: S-2 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Chan neIization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know he same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit agree to the conditions attached to this permit. ` Signature: Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 11: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC906.5) 12: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 13: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 14: Maintain fire extinguisher coverage throughout. 16: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 17: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 18: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13-16.1.4) 19: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 23: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 w 1700 BUILDING FINAL" 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUKWILA Community Development Department • Public Works Department • Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httl2://www.TukwilaWA.P,ov SITE LOCATION Site Address: Tenant Name: Building Permit No. Project No. Date Application Accepted: Date Application Expires:` CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" a-/ PROPERTY OWNER Name: Ztl h Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: � y'1 Address: City: 42� State: W Zip: Phone: db 053 �d6 Email: GENERAL CONTRACTOR INFORMATION Company Name: / L G Address: ` 00 c• City: State: J r J Zip: 0 Phone: QV 016 Contr Reg No.: A. c(21 te: (? /„ ! 0 Tukwila Business License No.: M I (d King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: t9..... Yes ❑..No ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Engineer Name: %�! J p Address: // l 5-e City: State: W1 Zip: s/ V" Phone: .?65 ax: Email: , . Q fal r LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: t H:\Applicvions\Foms-Applications On Line\2011 ApplicationsWerntit Application Reused - 8.9-11.docx Revised: August 2011 Page 1 of 4 bh BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ O U V l vv Existing Building Valuation: $ Describe the scope of work (please provide detailed information): CS � - . n s xzy Will there be new rack storage? P..... Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I' Floor 2" Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑....... Yes El ....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ ....... Sprinklers ❑ .......Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ....... Yes ❑ .......No If "yes', attach list of materials and storage locations on a separate 8-112"x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ ....... On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications\Fo=-Applications On Line\2011 ApplicationsTerntit Application Revised - 8-9-11.docx Revised: August 2011 Page 2 of 4 bh DESCRIPTIONS PermitTRAK PAID $457.90 D15-0118 Address: 1224 ANDOVER PARK E Apn: 3523049071 $457.90 DEVELOPMENT $444.56 PERMIT FEE R000.322.100.00.00 0.00 $266.70 PLAN CHECK FEE R000.345.830.00.00 0.00 $173.36 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $13.34 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: 1 1 R000.322.900.04.00 0.00 $13.34 $457.90 Date Paid: Monday, June 01, 2015 Paid By: MR RACKS Pay Method: CHECK 4986 Printed: Monday, June 01, 2015 1:26 PM 1 of 1 /.]�' L^' ISY57EM5 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN R AUTH AGENT: Signature: Date: �� Print Name: Day Telephone:_Jv� Mailing City State WApplimtionsWorns-Applications On Linc\2011 ApplicationsWe mit Application Revised - 8-9-1Ldom Revised: August 2011 Page 4 of 4 bh INSPECTION RECORD Retain a copy with permit L PERMIT 0. CTION N0. PT NO. C� CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect: ,d �� � nsp ction: J f Type o6tdql Address; � p� IF, / Date Calte pecial Instructions: Date Wanted: ra.m. r S p.m. Requester: Phone No: Inspector Date .ry. u REINSPECTION FEE REQUIRED. Prior to next inspection, flee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. t INSPECTION RECORD 3 O Retain a copy with permit �(3 = ®(�0 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request line (206) 438-9350 Project: Type of�ingection, l Addro tl� ���' Date Called: Special Instructions: Date Wanted: a.m. ` 2— �S p.m. '.f l�iv i Requester: Phone No: A� _� F` 1*1 (Inspector: I Date-7_ 2—_ lS REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Catt to schedule reinspection. M INSPECTION RECORD �f� �f s Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF" TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro)',ect: t. co i% -P-'+wtA /� k l� Type. of,ln�pectioon-: r (( �a 1-( Address: Date Call . Special Instructions: Date Wanted: f a.m. p.m. � Requester:�`�,, t- /�ll� f �G �.Y Phone No. ,57 - A 1l� �/ - l � c_p- iV Approved per applicable codes. Corrections required prior to approval. • Inspector: Date: / _ r� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. kfk Inspector: Date: / _ r� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. kfk INSPECTION RECORD Retain a copy with permit ' D 1 ( 7 N-WSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of,p tion:. C Addres Date Called: Z G Special instructions: Date Wanted: a.m. I— p.m. Requ s Efm go, ,s"W t It��Fj Phone No: Approved per applicable codes. Corrections required prior to approval. • FEW Inspector: Date: { ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD � /�5—, 0 ► le' Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ��earc � � � ft� r►^e c �► r�c�e,c/ Type f Inspection: C� Address: jaa�%�E- Contact Person: Suite #: Special Instructions: Phone No.: C2-Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: kArl �f gjNa,--{� Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 46 S- — Date: --71, IZ N.-- I Hrs.: 1 ❑ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. timing Aaaress Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 6 MW INSPECTION RECORD Dl S - n 119 Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Pro'ect: nvr LowIJ 7Or4 Type of Inspection: 2 �� Address: 1 % P� Contact Person: Suite #: Special Instructions: Phone No.: 1-1 Approved per applicable codes. 51 Corrections required prior to approval. COMMENTS: ?Ac_%S r i tx �r-�-� J� p fnvf� � tvrv-. r ��u, ��t cif' ��•� >r� U+� r0 !0it tri I�AL�t Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: � Inspector: 4^ gl,,, I Date: 6/,� 3//�c— I Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Bming Aaaress Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORD D- 0 ! Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of In% Address: J g�i Contact Person: Suite #: Special Instructions: Phone No.: Approved per applicable codes. Vkorrections required prior to approval. COMMENTS: r C . to T r ^ Al ,�I- '1` lP r Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:' N1 �- Date: (�Z , /� Hrs.: ❑ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Fireproofing Aggregates S h o t c r e t e Concrete Masonry A s p h a l t Roofing P i I i n g S t e e l S o i l s W o o d July 2, 2015 File No. 15-409 Building Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Georgetown Home & Garden Address: 1224 Andover Park E. Permit: D15 0118 A.A.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTION AND MATERIAL TESTUr„ NATIONALLY ACCEPTED LABDRATORY This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and a copy of our inspection report is attached. 1. Proprietary anchor installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and/or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. Kimberle Anderson President CC: Mr. Racks — Carey Ferguson Georgetown USA -Mike Pack RECEIVED CITY OF TUKWILA JUL, 0 2 2015 PERMIT CENTER Tel: (425) 881-5812 Fax (425) 881-5441 • 7126 180th Ave. NE. P.O. Box 2523 • Redrnond, WA 98073 Field Report Report#: 62644 `T ___ . _.. t _._._ ._,.�.. , A:AR, Testing Laboratory, ine. 7126 18f)tfi: Ave:N.E., Park• 18(3 Suite C101,. Redmond, YVA $8052 i Pone42 81.58i2 5�$81 .1 Client: Mr. Racks Project Number: 15-409 500 S.W. 16th St. Permit #: D15-0118 Renton, WA 98057 Project Name: Georgetown Home & Garden Contact: Carey Ferguson Address: 1224 Andover Park E. Inspection Performed: Proprietary Anchors Date: 6/23/2015 Time: Temperature: All bolts for pallet racks. rified installation of Simpson Strongbolt 2 anchors, 1/2" x 4 1/4" with 3" embedment. Torqued to ft. lbs. RECEIVED CITY OF TUKWILA JUL 02.2015 PERMIT CENTER Distribution: © Distribute Client ❑ Distribute Contractor ❑ Distribute Engineer Distribute Owner Inspector: Trow, Michael g' Distribute Municipality ❑ Distribute Other Reviewed by: Michele Guerrini ❑ Distribute Architect ❑ Distribute Other d All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden ' r1" Field Report Report M 62631 AAR. Testing Laboratory, lnc. 7126 180tti,Ave.N':E., Park 180; Suite C101, Redmond, WA 98tf52 Phone 425.Ul.--R12 Fax 425.881.5441 Client: Mr. Racks Project Number: 15.409 500 S.W. 16th St. Permit#: D15-0118 Renton, WA 98057 Project Name: Georgetown Home &Garden Contact: Carey Ferguson Address: 1224 Andover Park E. Inspection Performed: Proprietary Anchors Date: 6/22/2015 Time: Temperature: Anchor bolts for pallet racks. t was noted that a majority of anchors were not torqued to 60 ft. lbs. Nill re -inspect when complete and torqued. RWENW IJUL O U0 2 Distribution: V�J Distribute Client ❑ Distribute Contractor Inspector: Trow, Michael ❑ Distribute Engineer ❑ Distribute Owner FVJ Distribute Municipality ❑ Distribute Other Reviewed by: Michele Guernni ❑ Distribute Architect ❑ Distribute Other All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden FILE PROJECT: 46004F. T D100 ROME 0 A bW DATE M Apt 20t S PAGE t QE I ENGINEER: S*nL To& go 1S©2"t SUBJECT: STtEt. RN' F*O'A TZAc.l+c. A#JALq sts �;&GluQ."aTgc- 10DW I. Lou— 4 $E-c 15. S. ?e at- ASS 7-to ustt4& Tge Avo mvrooD : V m .6-1 cs rp ids Ss, s 1.4t iv rvIL TUt IAAG►QT4 A0jDfifZjX. f / � rC • 12660 � '� � ` � o TI-AIJSV, ( 6AAC64)� SS�Oti.�L } �r ' o. Q4 ids . R = LoO&&r. (mag) ILL, VL Q.1v5C. ws . 1 s �- p, torl. PLW . 9L 4- ac + .Z,� I-L j Wsem LL = CODE COMP .ic.C>c l., �? 4.tsU.. C paoA. as<s is APPROVE (a) Omt VE A 3,caoo Lbs, Ustr tooW/trave- F&IL Mck. D JUN 0 9 2( (b) a" ITP E 'Z, co o Lot, fb& Kgc u L- I .o to 6" Bs ILc T 09 s . t~ A ►�� s Ws , . (.'Jt 1000 t t a c� - 2410 Hof T kv '"-- EIIRDING DIV Akjj r, 0- *0 2.1t L000 ant 7t? LtVe-L rs+Aicj t, + 4. t Ce 191" it 7' : ti.4Z � t%: 44,1 � #A C40m c.a 2000 + 1 as sew 3.0q k L*Av *Ai 7vp LE yet oAx., %/r; 33,3 tq "!!?v. -r 0. 47, � V: 0.jz /c.t`t AtAIL t-ompfc �."7S 3.c0q. b -1- tie 20 2- ISM 4A4 c Wt t RECEIVED %&, _ _ _ CITY OF TUKWII. JUN012015: 5 PERMIT CENTER i DATE._P- -- '4015' PAGE -2- OF � ENGINEER: I"oA da I soZy SUBJECT: PROJECT: A)n z 12-1015 W 1P�ccr Es{E-3o3-: w`� S i&L rWsP&CTIorJ VA =-04aLgi �nvmll-3wfh z2rlx}��.5'1 5,0 ep ",I Ca,=It. r. i s at; ,Ii -d, a 140 --'T MIS w. -r,, _ m4-v Lft ,uA* V. z t:8O (As �''`ldr►�n + Vtic*V, , 0.7r (,Nh w) — tok e- i . Z w r,le S6) 2 t:7.G8" T1#6 /�'/ ►"° ,� t. G2 �` =Y 0.75 i° = L. 22k /I. At vb. Zg[� ne.y ' cw v 101401 k`"i ,,3''c , owS 3 t� r p, C ) h • 167.40 4' Ile. Ac 65' 42.'E 00 G�t1c p _ : S. S Z. Agast= nthTes AYL& c�-`� 7 VIF' Ap v -Mao �z 4��+p�,tQ.t-0? *Si�/� ®kr► < A14,00 � T D.7F {cr = /• rb s '15 F-t z Z'l k�D: --'7 gal 0►2A(m" .. dPK { ACrdAt 4- sh A444W 'rt = e, ¢ C-F�'y'gf U = 9 per: (3ftRt jJ 6 Ab 7. (zQ F 5. o 4,a) (za f S`.o+ -7 . ©) /� .� z G.� �S ►�► �` Pa Abi, A koi s 4.92 -. vk 7 hI,o k' CoAtiq F'c Lbrl 1Dix 7Y,*C- A 046-ta �•u�� L k AOL vAIM 0 • oil & d PROJECT: DATE 05 -- 201 S'' PAGE OF 3 ENGINEER• !�ZA8Ao I50Z"7 SUBJECT: : PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0118 DATE: 06/01/15 PROJECT NAME: GEORGETOWN HOME & GARDEN SITE ADDRESS: 1224 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter #, DEPARTMENTS: aS AW ti Building Division Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) REVIEWER'S INITIALS: Revision # before Permit Issued Revision # after Permit Issued AM AW6 Fire Prevention Planning Division ❑ Structural ❑ Permit Coordinator 61 DATE: 06/02/15 Structural Review Required ❑ DATE: DUE DATE: Approved with Conditions i Denied ❑ (ie: Zoning Issues) 1l7:rIN Perinit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 06/30/15 12/18/2013 Page 1 of 2 Hone; Inicio en Espanol Contact Safety (0 Washington State Department of Labor & Industries MR RACKS LLC Owner or tradesperson Principals Ferguson, Carey Scott, PARTNER/MEMBER Ferguson, Julie Lynn, PARTNER/MEMBER Ferguson, Carey Scott, AGENT GONSER, BRETT, PARTNER/MEMBER (End: 04/30/2013) MCLENDON, ROBERT, PARTNER/MEMBER (End: 04/30/2013) Doing business as MR RACKS LLC Search L&II A-Z Index Help Tvty Secure I: Sri Claims & Insurance Workplace Rights Trades & Licensing 500 SW 16TH ST RENTON, WA98057-2625 425-207-0058 KING County WA UBI No. Business type 602 779 014 Limited Liability Company Governing persons CAREY FERGUSON JULIE FERGUSON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .................................... . Meets current requirements. License specialties GENERAL License no. MRRACRL9248N Effective — expiration 01/03/2008— 01/17/2016 Bond AMERICAN CONTRACTORS INDEM CO $12,000.00 Bond account no. 100031015 Received by L&I Effective date 01/03/2008 12/20/2007 Expiration date Until Canceled Insurance ........................... Ohio Security Ins Co $1,000,000.00 Policy no. BKS1654674031 Received by L&I Effective date 05/27/2015 06/29/2015 Expiration date https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602779014&LIC=MRRACRL924BN&SAW= 6/15/2015 ` - 661- 1�� 6 NOTES: 1. ALL PALLET RACK POSITIONED TO LEAVE A 6" FLUE SPACE MINIMUM ON ALL SIDES WHEN LOADED. 2. BUILDING COLUMNS ARE 3. SHELF SUPPORTS ARE WIRE DECK - NO SOLID SHELVES 4, 619 3 D SQ FT WAREHOUSE AREA - APPROX. 1 �.011 N1oo CO CIN M ,-4 811 44" X 96" 44" X 96" 44" X 96" 44" X 96" 44' X 96" 00 0 1 t-011 N 1 170 CA x x Q W a 1.011 2 a W a W 0. x tD x a a W HARTUNG UNLOAD AREA � 2p'-9" RA CK THIS SIDE INSTALLED UNDER SEPARATE PERMIT 0 0 N—� REV EWED FOR CODE COMPLIANCE APPROVED JUN 0 9 2015 Ci of Tu ila BUILDING DIVISION FILE COPY Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt Of approved Field Coy and conditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope Z of work without prior approval of LLJ Tukwila Building Division. NOTE: Revisions will require a new plan submittal M and may include additional plan review fees. �-- . oa iW a ��'� a l00 e-1gQ�vj Waco o RECEIVED CITY OF TUKWILA = W JUN012015 �030 0 in >- PERMIT CENTER � Q „ �. -- �` >: W c, C7 ce- 0 . 1 DRAWN BY: 12660 'fs,S/R�L �R .�� SI344�� CF N. C� SCALE: 3/32" = 1-0" DATE: 02-05-2015 DRAWING NO: CHECKED BY: s..,o B. KATTUTA SHEET NO. i OF 2 sHEFrs .531 SQUARE 8' 00 00 400 N d SIDE FRONT SIDE FRONT RACK TYPE A RACK TYPE B RACK ELEVATIONS .375 R 3" 14GA THK. LM20 14GA ASTM A572 GR50 Ve R11W TIP. SCALE: 3/8" = 1'-0" 1 IX-" 14 CIA THK, FE' 1"4 " COLUMN STRUT "IM A rVEr".T A CI ClIEr m BEAM SECTION 14 GA THK. ASTM A572 GR50 MeAl 8i 5/8" DIA. 2 HOLES 3/8" THK. — 3" 3/4" 7" �I 3/16" 1 1/2" BASE PLATE DETAM RACK AND SHELVING DETAILS SCALE: 3" _ 1' 0" STRUCTURAL NOTES. 1. RACKS ARE MANUFACTURED BY INTERLAKE OF MELROSE PARK, IL, OR EQUAL. 2. MINIMUM YIELD (Py) AND ULTIMATE (Fu) STEEL STRENGTHS FOR SELECTIVE RACKS SHALL BE AS FOLLOWS: (a) BEAMS AND COLUMNS Py=551si Fu=70ksi. (b) BRACING STRUTS Py=36ksl Fu=58ks1. (c) BASE PLATES FY=36ksi Fu=581si. 3. MAXIMUM RACK LOAD PER LEVEL PER PAIR OF BEAMS SHALL BE AS FOLLOWS; (a) RACKS TYPE A: 3,000LBS (b) RACKS TYPE B: 2,000 LBS 4. CONCRETE SLAB IS ASSUMED AS 5" THICK WITH fc'=UOO psi. 5. ALLOWABLE SOIL BEARING PRESSURE IS ASSUMED AS 1,000psf FOR GRAVITY LOADS. 6. TIE -DOWN ANCHORS SHALL BE SIMPSON STRONG BOLT 2 WEDGE ANCHORS. USE TWO (2) 1/2" 0 X 4-3/4" ANCHORS WITH A 3" EMBEDMENT PER BASEPLATE AS FOLLOWS: RACKS TYPE A & B USE TWO ANCHORS PER BASEPLATE SPECIAL INSPECTION IS REQUIRED. 7. POST LOAD SIGNS NOT LESS THAN 50 SQUARE INCHES IN AREA SPECIFYING THE DESIGN CAPACITY AT CONSPICUOUS LOCATIONS. 8. IF ANY DISCREPANCY OCCURS, CONTACT THE ENGINEER FOR CLARIFICATION. 9. ANALYSIS AND DESIGN OF RACK CONFORMS TO THE 2012 IBC SEC 2209, THE 2008 RMI CODE, AND SEC.15.5.3 OF SEVASCE 7-10 USING THE ASD METHOD WHERE: V = Cl Cs Ip Ws AND Ip 1.0 (RESTRICTED AREA - NO PUBLIC ALLOWED) Sg-- 1.426 Cs = 2.5 Cs/R AND Ca= 0.3803 FOR THE GIVEN ADDRESS AND SITE CLASS D R = 4.0 BRACED DIR. - TRANSVERSE (BRACED) DIR, S1 0.531 R = 6.0 UNBRACED DIE. - LONGITUDINAL (MOMENT) DUL Fa 1.0 FIRE PROTECTION NOTES: 1. SPRINIMM SYSTEM DENSITY IS 0.390PM/5,600FT Z 2. HEAD TEMPERATURE IS SET AT 286 ° f 3. TYPE OF PRODUCT: CLASS I METAL YARD DECORATIONS STORED IN CARDBOARD BOXES. 4. TOP OF STORED PRODUCT NOT TO EXCEED 18'-011. 5. APPROXIMATE CEILING HEIGHT 25'-0". EXITING NOTES: 1. EXTERIOR DOORS ARE 3' SWIIdO TYPE W1TH LOCKING KNOB VIRIIGH REQUIRES NO SPECIAL KNOWLEDGE OR EFFORT TO OPEN. 2. E7CfBRIORSIIIT DOORS TO BE MARRY PERA"LICABiB CODE UPRIGHT COLUMN 1" Qvm REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 9 2015 City of Tukwila BUILDING DIVISION DIAGONAL BRACE (TIP.) HORIZINTAL BRACE rYP.) BRACING CONNECTION DETAIL RECEIVE[ ks's�° CITY OF TUKWIL,A J U N 0 1 2015 ERMIT CENTER C4 ti a W 0 a� � W Z W 0000 Q _ O�'oo _0:�C" q Z LAJ �► Q J Q 0 H W Q LLJ N = W Q DRAWN BY.- CF SCALE. - AS SHOWN DATE.• 2-5-2015 DRAWING NO. CHECKED BY.• B. Kattula SHEET NO. 2 OF 2 SHEETS