Loading...
HomeMy WebLinkAboutPermit D15-0128 - ODIN BREWING - INFRASTRUCTURE MODIFICATIONSODIN BREWING 402 BAKER BLVD D15=0128 City of Tukwila • Department of Community Development + 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 0223100031 Permit Number: D15-0128 Address: 402 BAKER BLVD Issue Date: 6/30/2015 Permit Expires On: 12/27/2015 Project Name: ODIN BREWING Owner: Name: MRFH LLC Address: 2305 HUGHES AVE SW, SEATTLE, WA, 98116 Contact Person: Name: DAN LEE Address: 402 BAKER BLVD , TUKWILA, WA, 98188 Contractor: Name: AFFIDAVIT- DAN LEE Address: License No: Lender: Name: VALHALLA BREWING & BEV CO Address: 402 BAKER BLVD , TUKWILA, WA, 98188 Phone: (206) 953-1353 Phone: Expiration Date: DESCRIPTION OF WORK: INFRASTRUCTURE MODIFICATIONS TO MOVE BREWERY MANUFACTURING TO EXISTING MANUFACTURING SPACE ADJACENT TO EXISTING TASTING ROOM. EXPANSION OF EXISTING TASTING ROOM KITCHEN INTO FORMER OFFICE SPACE. KITCHEN EXPANSION APPROX 200 SF. Project Valuation: $30,000.00 Fees Collected: $1,155.24 Type of Fire Protection: Sprinklers: YES Fire Alarm: NO Type of Construction: IIIB Occupancy per IBC: F-2 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No 10f)l Permit Center Authorized Signature:w[L Date: I I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: / �- Date: O Print Name: %Ul� IZ C— I - c Ei5- This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 13: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Maintain fire extinguisher coverage throughout. 16: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 17: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 18: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 19: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 20: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 24: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 22: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 21: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 23: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 26: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 25: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 27: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 28: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 29: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 30: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 31: Equipment must comply with development agreement (1-13-0047) condition 4.3.3: "Utilizes an air treatment system and or other machinery so that the brewery meets Puget Sound Clean Air Agency Regulations regarding odors and that the brewing process does not cause off site impacts on neighboring properties or create a public nuisance." PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH & GYPSUM rW—V I CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hU://www.TukwilaWA.Rov Building Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 0223100031 Site Address: 402 BAKER BLVD, TUKWILA, WA 98188 Suite Number: Floor: Tenant Name: ODIN BREWING New Tenant: ❑ .....Yes O..No PROPERTY OWNER Name: MRFH LLC 399999 Address: 230514UGHES AVE SW City: SEATTLE State: wa Zip: 98166 CONTACT PERSON — person receiving all project communication Name: Dan Lee Address: 402 Baker Blvd City: Tukwila, State: WA Zip: 98188 Phone: (206) 953: J�` F Email: GENERAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: d a/1/L-eQ � ad r ki � R&-u i J ARCHITECT OF RECORD Company Name: Hinge Studio LLC Architect Name: Kate Cudney Address: 2346 16th Ave S City: Seattle State: WA Zip: 98144 Phone: (206) 948-9850 Fax: Email: kate@hingestudio.net ENGINEER OF RECORD Company Name: NA Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: VAtHt1 ,)q IXE-tt)lll� ,,,, JJ &V ' J CLe-, Address: 0 ,2-- 7S GLIP City: -fu ew' L A State: w v l Zip: oGe1N\ H:\Applications\Forms-Applications On Line\2011 ApplicationsTermit Application Revised - 8-9-1 Ldocx Revised: August 2011 bh Page 1 of 4 rwwlw It BUILDING PERMIT INFORMATI0r% — 206-431-3670 Valuation of Project (contractor's bid price): $ 30,000 Existing Building Valuation: $ 131,000 Describe the scope of work (please provide detailed information): &,D& aN l Infrastructure modifications to move Brewery Manufacturing to existing Manufacturing space adjacent to existing t�mg room. Expansion �� 17 Expansion of existing tasting room kitchen into former office space. Kitchen expansion approximately 200 sf. Will there be new rack storage? ❑..... Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC V Floor 12,825 9,566 0 0 1IIB B, F, A-2 2 Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 53,504 Floor area of principal dwelling: 0 Floor area of accessory dwelling: 0 *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 32 Compact: Handicap: 2 Will there be a change in use? El ....... Yes 91....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® ....... Sprinklers El ....... Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? El ....... Yes ❑ .......No If `yes', attach list of materials and storage locations on a separate 8-112"x I "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 ApplicationsTennrt Application Revised - 8.9.11.dom Revised: August 2011 Page 2 of 4 bh PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Kate Print Name: Mailing Address: 2346 16th Avenue South Date: 06/02/2015 Day Telephone: (206) 948-9850 Seattle WA 98144 City State Zip H:Wpplications\Forms-Appheations On Line\2011 ApplicationsTermit Application Revised - 8.9-1l.docx Revised: August 2011 nn Page 4 of 4 DESCRIPTIONS ACCOUNTQUANTITY PAID PermitTRAK $315.18 D15-0128 Address: 402 BAKER BLVD Apn: 0223100031 $315.18 Credit Card Fee $9.18 Credit Card Fee R000.369.908.00.00 0.00 $9.18 DEVELOPMENT $306.00 PERMIT REINSPECT FEE - AFTER HRS INSP R000.359.000.00.01 0.00 $306.00 FEE TOTAL FEES PAID BY RECEIPT: R11437 $315.18 Date Paid: Monday, May 08, 2017 Paid By: VALHALLA BREWING & BEV CO Pay Method: CREDIT CARD 030409 Printed: Monday, May 08, 2017 11:04 AM 1 of 1 SYSTEMS DE SCR I PTIONS PermitTRAK ACCOUNT QUANTITY $715.25 D15-0128 Address: 402 BAKER BLVD Apn: 0223100031 $715.25 DEVELOPMENT $681.40 PERMIT FEE R000.322.100.00.00 0.00 $676.90 WASHINGTON STATE SURCHARGE E1640.237.114 0.00 $4.50 TECHNOLOGY FEE $33.85 TECHNOLOGY FEE TOTALPA6i4 R000.322.900.04.00 0.00 $33.85 Date Paid: Tuesday, June 30, 2015 Paid By: ODIN BREWING Pay Method: CHECK 6667 Printed: Tuesday, June 30, 2015 12:27 PM 1 of 1 p"fSYSTEMS Date Paid: Thursday, June 04, 2015 Paid By: HINGE STUDIO LLC Pay Method: CREDIT CARD 092620 Printed: Thursday, June 04, 2015 8:33 AM 1 of 1 CfSY57EM5 INSPECTION RECORD Retain a copy with permit Dina ()-z8" INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: C>D/N Type of Inspection: AALP)N& F/X,4(-L Address: Date Called: z B zRLb�� Special Instructions: Date Wanted: a. . p.m. Requester: P)w Phone No: 210te-0(.53-13is Approved per applicable codes. Corrections required prior to approval. Inspector: % Date: j/ ,7—/ / L REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Catt to schedule reinspection. INSPECTION RECORD Retain a copy with perms INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ODD �1Wt�®A16- c o . Type of Inspection: _ �cCC "(940�7/k Address: 6A 4twR Date Called: Special Instructions: Date Wanted: a.m. 11-1 7 p.m. Requester: Phone No: ElApproved per applicable codes. jam' Corrections required prior to approval. COMMENTS: CeFZR,9C'_?7O1VS" Inspector: Date: 2!==�/C—/ 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORDn7 I �(�'-�f Retain a copy with permit IN 10N N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P6) 2 (A) Ty a o Inspection, < t4 Address: 4� 7. i Date Called/ Special Instructions: Date Wanted: a.m. ( 46 p.m. Requester: Phone No: DApproved per applicable codes. LJ Corrections required prior to approval. M ENTS: M Inspector: JDate';5_ (6 f REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD La % Retain a copy with permit i ECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (205) 431-3670 Permit Inspection Request Line (206) 488-9350 PM1Dt' Type of Insp ction:. ( r tdj Address: / 6k/ Date Called Special Instructions: Date,Wantte a.m. �3 p.m. Requester:— Phone No: EApproved per applicable codes. I X 1 Corrections required prior to approval. •� (OJi ��� 9 WMTA ' 9 f S_/616 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. INSPECTION RECORD Retain a copy with permit I SPEC NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 G rC( ( 1Aq �- Project: Type of Ins ection:( Address: �� '/mil I� Y Date Called: Special Instructions: Date WanteG a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. Inspector: Date1 ^� u REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. lij INSPECTION RECORD a Retain a copy with permit �� �� IN ION NO. PERMIT NO. CITY Of TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pei t:� Type of Inspection: Add,re v J d + Date C i d: Spee11cial Instructions: /9- Date Wanted: a.m. � (R _ � p.m. Requester: i Phone No: Approved per applicable codes. LJ Corrections required prior to approval. Q- &" Inspector: �/ fi �Date:� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. etc INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: a Type of Ins p ction:, --� Address: 4/0 2, Date Called: Special Instructions: Date Wanted: :m. Requester: Phone No: Approved per applicable codes. ' Corrections required prior to approval. u paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Q INSPECTION RECORD � Retain a copy with permit Q��pi � �l INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ko' P-:>Oze !.i� Type of Inspectio%� % Address: n� q6, kl - 1 Date Called: Special Instructions: Date Wanted: / ) I /J p•m Requester: / Phone No: Approved per applicable codes. El Corrections required prior to approval. L __1 paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of lnspectio Address: e �- '8'+ r 131 Date Called: // Special Instructions: Date Wanted: A a.m. Requester: Phone No: FlApproved per applicable codes. EI Corrections required prior to approval. COMMENTS: fi Inspector: pate: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projec�, Type of Ins ecti n: Address: e B Date Called: Special Instruction : 1 Date Wanted: a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. tJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. j� INSPECTION RECORD Retain a copy with permit 495 D% INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � ' � Type of In�pection: ,fit I � Address: Date Called: Special Instructions: ,op/�j Date Wanted: a.m. Requester: T Phone No: Approved per applicable codes. Corrections required prior to approval. Inspector: �``�� Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2— INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Inspection:je,ction: f Address: a YZ� n U Suite #: G� � � +7 Contact r'n: Special Instructions: Phone No.: � P-�<] Approved per applicable codes. COMMENTS: C e rZ --LT? G /,-j S_ Corrections required prior to approval. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: -W "/� 1 Date: l IIWI -j_ Hrs.: ❑ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department: Call to schedule a reinspection. tsming Aaaress Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORD 1 xI --n(_� Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: t , A,�•.� Type of Inspection: �, � 01< Address: Suite #: (DZ 7 4� _- Contact Person: Special Instructions: Phone No.: Approved per applicable codes. ❑ Corrections required prior to approval. r COMMENTS: i Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:..�,� _, Wl ( S I I Date: �G //5-)/ I(, I Hrs.: / _r, $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. isming Aaaress Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 9/29/2017 DAN LEE 402 BAKER BLVD TUKWILA, WA 98188 RE: Permit No. D15-0128 ODIN BREWING 402 BAKER BLVD Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on i in/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/7/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley1 Permit Technician File No: D15-0128 6300 Southcenter Boulevard Suite #100 9 Tukwila, Washington 98188 9 Phone 206-431-3670 • Fax 206-431-3665 • OFF HOURS INSPECTION • Reimbursement authorization/approval to conduct inspection activities during off hours. Date: Requested �A-/v 4(! Firm/Company: l Inspection Information Permit Number:2 [ S— - b ( ZR CID CITY OF TUKWILA MAY 0 8 M117 Project Name:_ �n V ��Z1/ iV a Project Address/Location: 402 SjL- UP PERMIT CENTER Requested Date for Inspection: Contact Name: I )IL (. Special Conditions for Consideration: Requested Time: AM / PM Phone Number: _p A_ -'? '3 -- /3 /�- ** Contractor will be charged a minimum for three (3) hour inspection time for any off -hours inspection work at $102.00 per hour (minimum total of $306.00). This is to be paid at the time of request. ** The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate invoice will be issued for all inspection time in excess of three (3) hours. Signature: Printed Name: City Use Only: Approved: Disapproved: Date of Approval/Disapproval: Authorized Reviewer: Date: Mrs] Remarks: Receipt No: W:\Permit Center\Applications-Handouts\Templates\Forms\Off Hours Inspection 1-2017.docx Revised: January 1, 2017 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 4/3/2017 DAN LEE 402 BAKER BLVD TUKWILA, WA 98188 RE: Permit No. D15-0128 ODIN BREWING 402 BAKER BLVD Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/14/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/14/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley Permit Technician File No: D15-0128 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development - Jack Pace, Director November 14, 2016 Dan Lee Odin Brewing Company 402 Baker Blvd Tukwila, WA 98188 RE: Request for Extension #4 . Permit Number D15-0128 Dear Mr. Lee, Allan Ekberg, Mayor This letter is in response to your written request for an extension to Permit D15-0128. The Building, Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through May 14, 2017. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File: Permit No. D15-0128 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: Tukwila WA.gov 11 aDM� 1- SRLWI NC COMPANY 'brwnr.aw www.odinbrevAng.com 0) qdticirds' WWW.AD.LIARDSBEERSOM City of Tukwila Dept. of Community Development RE: Permit No. D15-0128 Dear Bill Rambo 402 Baker Blvd. Tukwila WA 98188 October 26, 2016 Request for Extension # Current Expiration Date: —I L{— Extension Request: G Approved for 4D d days ❑ Denied (provide explanation) Signature/Initials J I would like to request one final extension on this permit. We are experiencing a longer than expected delay in our integration of the brewing system. If there are any questions, please feel free to contact me at the number below. Sincerely, Signature Dan Lee - Managing Member - Valhalla Brewing and Beverage Co. LLC. (206) 953-1315 gdanlee@odinbrewing.com CC: WBP Date RECEIVED NOV 0120% COMMUNITY DEVELOPMENT City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 10/3/2016 DAN LEE 402 BAKER BLVD TUKWILA, WA 98188 RE: Permit No. D15-0128 ODIN BREWING 402 BAKER BLVD Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/l4/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/14/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 7�'Co C'VJ� Bill Rambo Permit Technician File No: D15-0128 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 * Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 4/ 1 /2016 DAN LEE 402 BAKER BLVD TUKWILA, WA 98188 RE: Permit No. D15-0128 ODIN BREWING 402 BAKER BLVD Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/11/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. INTA 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/11/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D15-0128 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 11/2/2015 DAN LEE 402 BAKER BLVD TUKWILA, WA 98188 RE: Permit No. D15-0128 ODIN BREWING 402 BAKER BLVD Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/27/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/27/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D15-0128 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY . PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0128 DATE: 6/4/15 PROJECT NAME: ODIN BREWERY SITE ADDRESS: 402 BAKER BLVD X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: Buil ing Division Public Works PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Revision # before Permit Issued Revision # after Permit Issued A-K /0C, V L, OJo G 6vl5 Fire Prevention Planning Division Im Structural ❑ Permit Coordinator ❑ DATE: 6/9/15 Structural Review Required ❑ DATE: DUE DATE: 7/6/15 Approved with Conditions 1W Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/19/2013 "'""' CITY OF TUKWILA Permit Center/Building Division J� ........,Wq 43 3 7 ter.••"" �•.. sy 206 1- 6 0 01. Department of Community Development Public Works Department 41 0 63oo Southcenter Boulevard, Tukwila, WA 98188 2o6 433-0179 k = Telephone: (2o6) 431-367o FAX (2o6) 431-3665 Planning Division isosl E-mail: tukplanPci.tukwila.wa.us 2o6 431-3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO: DI ,�_ D 1 STATE OF WASHINGTON) ) ss. COUNTY OF KING ) y 4N t G ( (;- (, � , states as follows: [please print name] 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.ogo applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number L1, and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction w k. Owner/Owner's gent* LAURIE A. WERLE Signed and sworn to before me this NOTARY PUBLIC STATE OF WASHINGTON Q1' d of 9U � C , 20 . COMMISSION EXPIRES MAY 29, 2018 N P BLIC In and for the State of Washington Residing at , County Name as commissioned: My commission expires: llsL'll V 18.27.ogo Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.7o RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; io. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; ii. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who. holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household appliance orother small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. *Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. PROJECT NAME: ODIN ADDRESS: 402 BAKER BOULEVARD TUKWILA,WA 98188 PARCEL: 0223100031 LEGAL DESCRIPTION: ANDOVER INDUSTRIAL PARK #2 W 172 FT OF S 190 FT TOTAL BUILDING AREA = 12,825 SF PROJECT AREA: 9566 SF SITE AREA: 53,504 SF PROJECT DESCRIPTION: KITCHEN EXPANSION INTO EXISTING OFFICE SPACE AREA PROJECT OWNER/RESPONSIBLE PARTY: ODIN BREWING ATTN WES PETERSON WES.PETERSON@ODINBREWING.COM (206)-243-6346 ARCHITECT: KATE CUDNEY HINGE STUDIO LLC . 2346 16TH AVE S SEATTLE, WA 98144 OCCU PANT LOAD DESIGN CODES: 2012 INTERNATIONAL BUILDING CODE WASHINGTON STATE AMENDMENTS 2012 INTERNATIONAL FIRE CODE 2012 WASHINGTON STATE ENERGY CODE 2012 INTERNATIONAL MECHANICAL CODE 2012 UNIFORM PLUMBING CODE CONSTRUCTION TYPE: III B - SPRINKLERED ZONE: TUC OCCUPANCY TYPE: B & F & A-2 (NO CHANGE) SPACE EXISTING SQUARE FOOTAGE PROPOSED SQUARE FOOTAGE PROPOSED CHANGE OCCUPANT FACTOR EXISTING OCCUPANT LOAD PROPOSED OCCUPANT LOAD OFFICE 360 160 -200 100 3.6 1.6 KITCHEN/BACK BAR 450 650 200 200 2 3 TASTING/ RETAIL 950 950 0 15 63 63 MANUFACTURING 7,470 7,470 0 1000 7 7 STORAGE 2,140 2,030 -110 500 4 4 INTERIOR PATIO 735 735 0 15 49 49 CORRIDOR/RESTROOM 2401 3501 110 01 0 0 TOTAL* 12,3451 12,3451 0 1 1301 129 * SF DISCREPENCY FROM BUILDING TOTAL DUE TO WALL THICKNESSES. PLANNING APPROVED No changes can be made. to these plans without approval from the Planning Division of DCD Approved Py: Gate. KWILA PARKWAY• a BWE RL BLVD %% STRANDER BLVD 3 LJ 18 VICINTY PLAN N.T.S. 60' SETBACK LINE PER PLAT 71/68-69 480.00, CALC'O 27.3` LLI Z Z W o U m Lu O c W z U N W w o v N W 00 C 20 MECHANICAL: NO CHANGE TO HVAC SYSTEM. PROPOSED COLD ROOM FOR KEG STORAGE DESIGN BUILD PERMITTED SEPARATELY. ALL PROPOSED WORK MUST MEET CURRENT CODE REQUIREMENTS. ELECTRICAL: ALL ELECTRICAL WILL BE DESIGN BUILD, PERMITTED SEPARATELY. ALL PROPOSED WORK MUST MEET CURRENT CODE REQUIREMENTS. LIFE SAFETY SYSTEMS: EXISTING SPRINKLER SYSTEM TO REMAIN. MODIFICATIONS TO EXISTING SYSTEM TO ALLOW FOR COVERAGE OF PROPOSED LAYOUT MUST BE PERMITTED SEPARATELY. PROVIDE SHOP DRAWINGS TO JURISDICTION AND FIRE DEPARTMENT FOR REVIEW AND APPROVAL. PROVIDE EGRESS LIGHTING AND EXIT SIGNAGE AS REQUIRED BY CODE. ACTUAL NUMBER AND LOCATIONS OF SIGNAGE UP TO THE DISCRETION OF INSPECTOR. PROVIDE 1 EYE WASH AND 1 CHEMICAL SHOWER (SEE A1.02 EQUIPMENT PLAN FOR LOCATIONS. PLUMBING: ALL PLUMBING WILL BE DESIGN BUILD, PERMITTED SEPARATELY. ALL PROPOSED WORK MUST MEET CURRENT CODE REQUIREMENTS. SIGNAGE: PROVIDE SIGNAGE AS REQUIRED FOR SAFETY EQUIPMENT INCLUDING EYEWASH AND CHEMICAL SHOWER. FIRE EXTINGUISHERS: TYPE FE: 5 LB CAPACITY FIRE EXTINGUISHER UL RATING 2A-10B:C (LARSEN TYPE MP5). BRACKET MOUNTED. 1. PROVIDE FIRE EXTINGUISHERS WHICH COMPLY WITH ALL CODES INCLUDING ADA REQUIRED MOUNTING HEIGHTS. 2. VERIFY FIRE EXTINGUISHER TYPES COMPLY WITH LOCAL JURISDICTION REQUIREMENTS. 3. PROVIDE CODE REQUIRED SIGNAGE ABOVE ALL EXTINGUISHERS 4. FIELD VERIFY LOCATION OF EXTINGUISHERS TO ALLOW FOR A MINIMUM OF 50' DISTANCE BETWEEN EXTINGUISHERS REVISIONS �_l . FofNoanges shalt be made to the scope work without prior approval of Tukkvila Building Division. r 101TE: ReviG?ens will require a new plan submittal anJ nc!ude m�' � `� arational plan rep 'ewi ­', BUILDING �1P hY�t �.9E BUILDING SBB'25'27'E 250. 01' . EXIST. SCREEN FENCE 10 �NLLINE EA VE ® z 0_ EXIST. COVERED STORAGE RECYCL Q Q z CL g EXIST. WALL-PAK r ITYP. 5 PLACES) �W — 0 z MEDIUM ROOF IO'x30' LOADING AREA ------ --------- m . r- z ------------------� : 19' 35'-6" c GATE X w HIGH ROOF 11 a o PATLO : O )SCAP NJ. 3 I �4 z C .' — Q �% t` fl T M IL Z I J I J m� I G_ Lo x W R, N RAMP J1 23' - RAISED WALK 1�7� I 0' � EXIST. LS _..: CONC;'SPEWALK.:'' '. ;rt �: ,��:...: 7' NBB•'5.27°. :.:50, of '�! a .♦ 1 '•'d,'. I 0-W oo❑ M.H. 3 j o ❑ a , F.H. (� i o o I 250. Of'. CALC'0 - BASIS OF BEARING SB8'25'27'E 1086.95' MEAS. �•— (1087.00' PLAT) BAKER BOULEVARD 'PUBLIC ROADWAY' - GENEML NOTES 1. FIELD VERIFY ALL DIMENSIONS PRIOR TO COMMENCING WORK 2. DIMENSIONS ARE TO FACE OF GWB, UNO 3. USE WRITTEN DIMENSIONS; DO NOT SCALE OFF DRAWINGS; FOLLOW DETAIL DRAWINGS IN PREFERENCE TO GENERAL DRAWINGS. 4. DRAWINGS INDICATE INTENT OF CONSTRUCTION. THE METHOD OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL MAINTAIN THE BUILDING'S STRUCTURAL INTEGRITY AT ALL STAGES OF CONSTRUCTION. 5. PATCH AND REPAIR FLOOR, WALL AND CEILING SURFACES AS REQUIRED TO MATCH ADJACENT FINISH LEVEL. 6. VFY LOCATION AND MOUNTING OF PROPOSED EXIT/ EGRESS LIGHT TO PROVIDE EGRESS REQUIRED LIGHTING PER IBC. 7. INSTALL FIXTURES, SYSTEMS, APPLIANCES AND EQUIPMENT PER MANUFACTURERS RECOMMENDATION, AND INDUSTRY STANDARDS. UNLESS OTHERWISE NOTED, PROVIDE ALL MISCELLANEOUS FASTENERS, HARDWARE AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. EVEN THOUGH SUCH ITEMS MAY NOT HAVE BEEN SPECIFICALLY MENTIONED IN THE DRAWINGS AND SPECIFICATIONS, NOTIFY THE ARCHITECT OF ANY REVISIONS OR ADDITIONAL INFORMATION OBTAINED FROM THE MANUFACTURER OF SPECIFIED MATERIALS OR EQUIPMENT WHICH MAY AFFECT THE CONTRACT TIME, COST, OR QUALITY OF THE WORK. PARKING: NO PROPOSED CHANGE TO LOT UFA per space UFA spaces manufacturing and accessory storage 1000.00 9,500 9.5 kitchen (counted as manufacturing for parking) 1000.00 650 0.65 off i ce 333.33 160 0.48 tasting room 100.00 1,685 16.85 total required 27 total provided 33 GOCCUPANT LOAD G) TOTAL OCCUPANT LOAD EXITING AT DOOR �.. POINT IN EGRESS PATH WHERE 2 SEPARATE AND DISTINCT PATHS TO 2 EXITS ARE AVAILABLE FE FIRE EXTINGUISHER, SEE NOTES EXIT EXIT SIGN SSs ;1 ATE PERMIT !.;,'�7QU1RED FOR: r^alchanical lrElectrical lumbing as Piping City of Tukwila UILDING DIVISION FILE COP' W"%% _AI6_9 Me — Ran review approval is subject to errors and omissions. I.pprovai of construction documents does not authorize t;-,o violation of any adopted code or ordinance. Receipt of approved Field C and conditions is acknowledged: By: Date: l City of Tukwila BUILDING DIVISION --4HATCH INDICATES PROPOSED WORK AREA o------------ o-------------o------------- o--------------- o-----=--------=- o -- I I l I 130` STORAG ,��/, �/ I INTERIOR PATIO 450 SF 735 SF 49 0 35'-1° i �/� i E PE ------ / B CK 130 ROOM FUTURE BOILER / // /� 3 5 S l C2) j%KITI' 3 � FE 13'-311 32`-4" � 0 OFFICE OTASTING FEW-1 11601 G cv! 52' DIST TO COMMON PATH 54`-8111 REV EWED FOR CODE COMPLIANCE APPROVED JUN 18 2015 City of Tukwila BUILDING DIVISION 0 OCCUPANCY DIAGRAM �i y .. hi.rlge I► ARCH r+ 00 00 r oo rn ~ U) Z J W � m U W OLO � Y �o r m dN N 0 12f O d d O 10139 EGISTERED AR H TECT KATHERINE R CUDNE STATE OF WASHINGT REVISION RECEWED CITY OF TUKWILA JUN #4.2015 PERMIT CENTER SITE PLAN eW" I � 13' 16'-4" - }----------------- I --------------- I I I II , 15' I I I I 2020' -----I-----------------------------------------------------I--- I I I I I I I I 20' 20'-4" 20'-4" --------------------- i-------------------------- --------------------- -,I I it it I �I C°� 2 1. CONTRACTOR TO VFY POWER, GAS, AND EQUIPMENT REQUIREMENTS FOR ALL EQUIPMENT. SEE SCHEDULE ON A1.02 FOR INFORMATION. PROVIDE UTILITY OUTLETS ALONG PERIMETER OF SPACE AND ON CENTE COLUMNS IN ADDITION TO THOSE SHOWN. KEY NOTE TAG KEY NOTES 1 EXTERIOR EQUIPMENT SEE EQUIPMENT PLAN 2 OVERHEAD GLYCOL LINES AND HOT AND COLD WATER LINES DIRECT VENT STACK AT HOT WATER HEATER 3 REQUIRES ROOF PENETRATION. CONTRACTOR TO VERIFY FLASHING AND ROOFING FOR WEATHER TIGHT PENETRATION. 4 TRENCH DRAIN 5 DASHED LINE INDICATES WALL TO BE DEMOLISHED 6 HATCH INDICATES EXISTING WALLS TO REMAIN 44" HIGH RAIL TO SEPARATE EXISTING INTERIOR 7 PATIO FROM MANUFACTURING SPACE. PROVIDE GATE FOR ACCESS AND EGRESS 8 REMOVE EXISTING SINK - SEE ENLARGED PLAN FOR PROPOSED SINKS AND EQUIPMENT. COLD ROOM. CONTRACTOR TO PROPOSE 9 MECHANICAL UNIT AND COLD ROOM WALL ETC. AS REQUIRED. 10 BREW HOUSE CONTROL PANEL SEE EQUIPMENT PLAN AND SCHEDULE. 11 CURB 12 REPLACE EXISTING ELECTRICAL PANELS PROVIDE POWER, GAS, PLUMBING AND OTHER 13 INFRASTRUCTURE PER ENLARGED KITCHEN LAYOUT, SEE A2.00 14 EXISTING FIRE RATED DOOR TO REMAIN CLOSED. 15 HIGH (48" SILL VERIFY) PASS- THROUGH WINDOW WITH SS COUNTER AND SHELVES 16 BREWERY EQUIPMENT/TANKS. SEE EQUIPMENT PLAN AND SCHEDULE. PROPOSED FULL HEIGHT WALL. WALL CONSTRUCTION 3 - 5/8" LG METAL, 25 GAUGE AT 16" 17 OC W/ 5/8" TYPE X GWB EA SIDE. 3'X7' HM DOOR AND FRAME WITH CLOSER. ALL HARDWARE TO MEET ADA REQUIREMENTS. 18 ALL DOORS SHOWN EXISTING UNO REViEWED FOR CODE COMPLIANCE APPROVED JUN 18 2015 City of Tukwila BUILDING DIVISION STUDS MUST BE FULLY - SEATED AGAINST TRACK RUNNER TRACK 600T150-43 NOTES: • WHEN TRACK IS ATTACHED DIRECTLY TO STUD FLANGE, A STANDARD NO. 6 x 7/16" .PAN HEAD SHEET METAL SCREW SHALL BE USED, WHEN DRYWALL COVERING, TRACK AND STUD FLANGES ARE ATTACHED AT SAME TIME; A STANDARD (MI.N.) 1" LONG DRYWALL SCREW SHALL BE USED, ANY COMBINATION OF THE ABOVE MATHODS MAY BE USED IN THE ERECTION OF A COMPLETED WALL ASSEMBLY. NO PUNCHOUT SHALL OCCUR WITHIN 12" FROM END OF STUD CONN. BOT. TRACK TO FLOOR W/.145"0 DRIVE PINS 4'-0"oc U.O.N. SCREW ATTACHMENT SEE NOTE BELOW TYPICAL WALL TRACK CONNECTION DETAIL IN THIS CONDITION TOP AND BOTTOM TRACK MAY BE HANDLED WITH SAME METHOD. NTS E IF — IV 0 T I ---- I ------------- I L El El MI. Separate Mechanical Permit shall be required for: Coolers, freezers, walk-in coolers and freezers, i.e. assembled and hardwired. *Self-contained "plugin" coolers or freezers (appliance type) shall not require a mechanical permit. I I — TRENCH DRAIN TYP. TOP OF GR TE AT EXISTING FINISH FLOOR LEV. V+FY DRAIN OUTLET SIZE FOR ADMATE FLOW. CONNECT TO' ' I P OPOSED HIGH POINT OF S B�ILT UP SLAB U V SLOPE TO DRAIN, TYP! MIN 8" PER V-0" V G NOTE: PROVIDE POWER FOR FUTURE APPLIANCES. SHOULD PRICING ALLOW FOR THE INSTALLATION OF HOOD AT THIS TIME AN ADDENDUM TO THIS PERMIT WILL BE SUBMITTED TO DOCUMENT HOOD EXHAUST AND MECHANICAL REQUIREMENTS C A 2 FUTURE 9 FUTURE 3 4 5 [6]— n I T U V T 11 W E LII — ---T I II 13 2 I 00P0000000 n Fi PF] F1 IR r1l q P IEI[]Fl Fl R P F I EXISTIN C Lj UTI LITINK F EXIS DISI WASHE EXISTING: - CON PART ENT SINK EXIS HOWATER DTVHEA E A IEXIS NSINK GENEML NOTES 1. CONTRACTOR TO VFY POWER, GAS, AND EQUIPMENT REQUIREMENTS FOR ALL EQUIPMENT. SEE SCHEDULE FOR INFORMATION. PROVIDE UTILITY OUTLETS ALONG PERIMETER OF SPACE AND ON CENTER COLUMNS IN ADDITION TO THOSE SHOWN. 2. FIELD VERIFY LOCATION AND REQS FOR EGRESS LIGHTING; EXIT SIGNS; 3. PROVIDE GENERAL UTILITY OUTLETS AT KITCHEN FOR ADDITIONAL TABLE TOP EQUIPMENT. VFY LOCATIONS WITH ARCH OR OWNER 4. VFY ADDITIONAL SWITCHING AND POWER PER OWNER KEY EQUIPMENTTAG KEY EQUIPMENT MAKE/ MODEL POWER REQS PLUMBING/ GAS/ AIR REQ OTHER 1 DISHWASHER ADS / AFC 3DS 115V SINGLE PHASE 1/2" SUPPLY, 2" DRAIN CONNECTTO EXIST GREASE TRAP 2 SMOKER Cook Shack Smoker 208/24015 amps (VFY) 3 WARMER Alto Shaam Halo 208/240 28.8 amps 4 FREEZER (FUTURE) PROVIDE POWER FOR FUTURE 5 COOLER Kelvinator Commercial Refrigerator 115 volts / 5 amps 6 COOLER Kelvinator Commercial Refrigerator 115 volts / 5 amps 7 STEAM TABLES (2) Adcraft Steam Tables 120v / 15 amps 8 PREP TABLE Sandwich prep table 115v / 8.3 amps 9 FUTURE HOOD VENT PROVIDE PRICING FOR 8' HOOD AND MAKEUP AIR 10 SINK W/ DRAINBOARD CON NECTTO EXISTING GREASE INTERCEPTOR W/ AIR GAP 11 PREP SINK CON NECTTO EXISTING GREASE INTERCEPTOR W/ AIR GAP 12 HAND SINK [13 �HANDSINK PROVIDE INSTAHOT HEATER ATSINK KEY EQUIPMENT MAKE/ MODEL POWER REQS PLUMBING/ GAS/ AIR REQ OTHER A BREW HOUSE Ripley Stainless 15bbl Mash/Kettle 3-phase (two pumps), 120v to control panel Hot/Cold H2O, gas for burner B FERMENTER CONTROL PANELS 24VAC from panel to solinoid C FERMENTERTANKS (13TANKS) low voltage from thermometer on tank to fermenter control panel glycol lines D FERMENTER GLYCOL SOLINOIDS 24VAC from panel to solinoid ATEACHTANK E GLYCOLCHILLER Pro Chiller 3-phase glycol line F COMPRESSERS NAPA Pro 240v G KEG WASHER/ FILLER IDD Mini Kng Three phase cold water, air, CO2 H HOT WATER HEATER (SMALL) Mighty Therm 115v gas, hot water toHLT DIRECT VENT STACK REQUIRES ROOF PENETRATION. I HOT LIQUOR TANK VERIFY WITH OWNER cold water, hot water from water heater J HOT WATER PUMP goulds 3phase supplies hot water loop K GRAIN CRUSHER robix-q 180 240v L COLD ROOM TBD 240v for compressor/refrigeration, vfy vfy M not used N BOTTLER (future) 115v cold water, air, co2 0 LABELER (future) 115v none P SINK AS REQ Q CHEMICALSHOWER AS REQ R OVERHEAD LINES glycol lines, hot and cold water lines S ICOMPRESSEDAIR COMPRESSED AIR DROP/DISCONNECT T OUTLET THREE PHASE OUTLET OR DISCONNECT U CO2 CO2 DROP/DISCONNECT V HOSE BIB Hot/Cold H2O HOSE BIB WALL MOUNTED OR ON STAND IF IN MIDROOM W BREWERY EFFLUENT PIT SUMP PUMP (FUTURE) POWER PLUMB INLETAND OUTLET FOR EFFLUENT TO FUTURE 1HOLDINGTANK 4'X4'X6' DEEP PIT M MM ���,v»rY�(y�(.51�;�t3iiYit{%t.tt�{ts3$�t1G.Y�t�s?i. i ?y U REVIEWED FOR CODE COMPLIANCE APPROVED JUN 18 2015 City of Tul(wila BUILDING DIVISION h 'in'1-j stud i i. ARCH I TECTU C 00 00 T- 00 'S J Y ~ Z � W � m ® W O u7 0, ECD — 0 m 0N -i ry O 11t 0-0 10139 REGISTERED ARCHITECT REVISION EQUIPMENT PLAN ZHEN FINISHES IOR: PAINTED OR SEALED VCRETE ,LLS: FRP WAINSCOT TO 4' . WORK/STORAGE SURFACES: SINLESS STEEL OR PLAM LING: ACT LAYIN CEILING (STING) KITCHEN PLAN Scale: 1/4" = 1'0" 1. CONTRACTOR TO VFY POWER, GAS, AND EQUIPMENT REQUIREMENTS FOR ALL EQUIPMENT. SEE SCHEDULE FOR INFORMATION. PROVIDE UTILITY OUTLETS ALONG PERIMETER OF SPACE AND ON CENTER COLUMNS IN ADDITION TO THOSE SHOWN. 2. EXISTING LIGHTING LAYOUT TO BE RELOCATED AS NEEDED TO PROVIDE ADEQUATE COVERAGE IN KITCHEN. 3. PROVIDE EGRESS LIGHTING AS REQUIRED. 4. SEE EQUIPMENT PLAN FOR MORE INFORMATION ON EQUIPMENT, PLUMBING AND ELECTRICAL REQUIREMENTS --o EQUIPMENT TAG KEY Nut"NTES 1 DASHED LINES INDICATE EXISTING WALL TO BE DEMOLISHED, PATCH AND REPAIR AS NEEDED. 2 DOOR TO BE RELOCATED 3 FUR OUT WALL BEHIND SINK 4 EXISTING SINK TO BE REMOVED S EXISTING FIRE RATED DOOR AND CLOSER TO REMAIN CLOSED 401 t It REVIEWED FOR CODE: COMPLIANCE: APPROVED JUN 18 2015 City of Tukwila BUILDING DIVISION