Loading...
HomeMy WebLinkAboutPermit D15-0159 - ANDOVER EXECUTIVE PARK - 564 BUILDING REROOFANDOVER EXECUTIVE PARK - 564 564 INDUSTRY DR D15-0159 City of Tukwila ' Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov DEVELOPMENT PERMIT Parcel No: 0223400010 Permit Number: D15-0159 Address: 564 INDUSTRY DR Issue Date: 7/20/2015 Permit Expires On: 1/16/2016 Project Name: ANDOVER EXECUTIVE PARK - 564 Owner: Name: BLUE DOG PROPERTIES TRUST Address: PO BOX 847 C/O THOMSON REUTERS PTS, CARLSBAD, WA, 92018 Contact Person: Name: STEVE STONE Address: 9500 AURORA AVE N , SEATTLE, WA, 98103 Contractor: Name: TECTA AMERICA SEATTLE LLC Address: 9500 AURORA AVE N , SEATTLE, WA, 98103 License No: TECTAAS905DH Phone: (206) 522-5436 Phone: (425) 881-9190 Expiration Date: Lender: Name: NCPW ANDOVER EXECUTIVE PARK Address: 810 NW MARSHALL#300, PORTLAND, OR, 97209 DESCRIPTION OF WORK: OVER LAY THE EXISTING CAP SHEET ROOF WITH A SINGLE PLY TPO ROOF SYSTEM Project Valuation: $40,132.00 Fees Collected: $1,441.34 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Occupancy per IBC: Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No LVAPermit Center Authorized Signature: '' W Date: 1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:-64 Date: Print Name:P�/�. �4 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 0103 PRE-REROOF CITY OF TUKWILA Community Development Department ' Public Works Department • Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.Izov SITE LOCATION Site Address: 564 Tenant Name: Building Permit No. W1 J. Project No. Date Application Accepted: Date Application Expires: T� (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" Dr Tukwila WA PROPERTY OWNER Name: Blue Dog Properties Address: PO Box 847 C/O Thomson Reuters City: PTS, Carlsbad State: WA Zip: 92018 CONTACT PERSON — person receiving all project communication Name: Steve Stone Address: 9500 Aurora Ave N City: Seattle State: wA Zip: 98103 Phone: (206) 455-7459 Fax: (206) 522-5472 Email: sstone@tectaamerica.com GENERAL CONTRACTOR INFORMATION Company Name: Tecta America Seattle LLC Address: 9500 Aurora Ave N City: Seattle State: WA Zip: 98103 Phone: (206) 522-5436 Fa": (206) 522-5472 Contr Reg No.: TECTAAS905DH Exp Date: 07/01/2017 Tukwila Business License No.: 43,s —o 9 yS'3 King Co Assessor's Tax Suite Number: Floor: New Tenant: ❑ .....Yes m ..No ARCHITECT OF RECORD Company Name: N/A Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: N/A Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: NCPW Andover Executive Park LL Address: 810 NW Marshall #300 City: Portland State: OR Zip: 97209 H:\Applications\Forrtts-Applications On Line12011 ApplicationsTerntit Application Revised - 8-9-11.do" Revised: August 2011 Page ] of 4 bh BUILDING PERMIT INFORMATIO,. — 206-431-3670 Valuation of Project (contractor's bid price): $ 40,132 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Over -lay the existing cap sheet roof with a single -ply TPO roof system Will there be new rack storage? ❑..... Yes Z.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I' Floor 2nd Floor 3r Floor Floors thru Basement Accessory Structure" Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 'For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? El ....... Yes El ....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ ....... Sprinklers ❑ ....... Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ....... Yes ❑ .......No If "yes, attach list ofmaterials and storage locations on a separate 8-112"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplicetions\Forma-Applications On Line12011 ApplicationsTertnit Application Revised - 8-9-11.do« Revised: August 2011 Page 2 of 4 bh PUBLIC WORKS PERMIT INF074ATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ..: Water District # 125 ❑ .. Highline ❑ .. Renton []...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ... Valley View ❑ .. Renton ❑ .. Seattle ❑ ...Sewer Use Certificate ❑ ... Sewer Availability Provided Septic System: ❑ On -site Septic System —For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted.with Application (mark boxes which ap ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ .. Right-of-way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut cubic yards ❑ .. Work in Flood Zone ❑ ...Total Fill cubic yards ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped Fire Line ❑ .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection " Irrigation " Domestic Water " ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size.. WO # ❑ ...Water Only Meter Size............ WO # ❑... Deduct Water Meter Size " ❑ ...Sewer Main Extension.............Public ❑ Private ❑ ❑ ...Water Main Extension.............Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Day Telephone: Mailing Address: City State Zip H:WpplicatiomkForms-Applications On Line\2011 ApplicationsTermit Application Revised - 8-9-Il.docx Revised: August 2011 Page 3 of 4 bb PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: A e ;t zw e- Mailing Day Telephone: City Date: State Zip H: ApplicationsTom Applications On Line\2011 ApplicationsTermit Application Revised - 8-9-11.docx Revised: August 2011 Page 4 of 4 bh DESCRIPTIONS PermitTRAK $5,946.66 D15-0158 Address: 742 INDUSTRY DR Apn: 2523049008 $2,559.00 DEVELOPMENT $2,483.87 PERMIT FEE R000.322.100.00.00 0.00 $1,502.65 PLAN CHECK FEE R000.345.830.00.00 0.00 $976.72 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $75.13 TECHNOLOGY FEE R000.322.900.04.00 0.00 $75.13 D15-0159 Address: 564 INDUSTRY DR Apn: 0223400010 $1,441.34 DEVELOPMENT $1,399.08 PERMIT FEE R000.322.100.00.00 0.00 $845.20 PLAN CHECK FEE R000.345.830.00.00 0.00 $549.38 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $42.26 TECHNOLOGY FEE R000.322.900.04.00 0.00 $42.26 D15-0160 Address: 630 INDUSTRY DR Apn: 2523049008 $1,946.32 DEVELOPMENT $1,889.21 PERMIT FEE R000.322.100.00.00 0.00 $1,142.25 PLAN CHECK FEE R000.345.830.00.00 0.00 $742.46 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $57.11 TECHNOLOGY FEE R000.322.900.04.00 0.00 $57.11 �TOTAL FEES PAID BY RECEIPT: R5615 . . Date Paid: Friday, June 26, 2015 Paid By: STEVE GRINAKER Pay Method: CREDIT CARD 08327G Printed: Friday, June 26, 2015 9:06 AM 1 of 1 Ow" SYSTEMS WW— . INSPECTION RECORD ,his 6 1� Retain a copy with per INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect IC46' .� Type of Inection:: y& Address: Date Called: Special Instructions: ff Date Wanted: a.m. 7-ZS—%' p.m. Requester: Phone No: Approved per applicable codes. 1-1 Corrections required prior to approval. M ENTS: U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. SEPARATE PERMIT RE -SQUIRED FOR: I"lectr1w R mbing Gas Piping City of Tukwilai �i�Il..d~i'LG DIVISION REVISIONS No changes shall he made to the scope of work without prior approval of Tukwila Building Division. ROTE: Revisions will require a new plan submittal and may include additional plan review fees. COPY Z , Permit NO, 0 IS Plan review oM is sul*d to WV and ombsiam. APP of construction documents dM not auduwritte the violation of any adopted cob orondnm, Receipt Of approved Field ns is actmawledged: Date: Z5— City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JUL 15 2015 tTcity of Tukwila BUILDING DIVISION A a J cc w -Y Lr) N W ~ >� � w U U Lu N m t g W Q FOR )r:--- COII��hPLIANCE 'I I JUL 15 2015 i Co N Standard Reflectivfty. Emissivity. CRRC® Initial 0.77 0.87 3 Yr. Aged 0.70 0.86 CA Title 24 Pass 0.77 0.87 ENERGY STAR® Initial 0.78 0.87 3 Yr. Aged 0.68 Not Tested LEED® SRI 101 Recycled Content Post -consumer. 0% Post-industrial: 5 /o Results shown are for the initial reflectivity and emittance for white membranes unless otherwise indicated; emissivity values for California Tide 24 are tested per ASTM C 1371; LEED emissivity values are tested per ASTM E 408. Peak Advantage' Guarantee Information Product Guarantee Term JM TPO FB 115 15 or 20 years Codes and Approvals $ un P CII M aml-0ode Coty APPROVED Product C.ArM App—d FILE Fleece Backed Thermoplastic Meets or exceeds the requirements of ASTM D 6878 Features and Components Integral Polyester Fleece Backing: In -line application of fleece allows for stronger bond for polyester backing that gives more flexibility in varying substrates for mechanically fastened or adhered systems. One of the Widest Melt Windows: Promotes better welds over a wider variety of speeds and temperatures, and leads to a softer, more flexible and workable sheet JINl IN }8115. Polyolefin Membrane CORWIent x: M �— - TM REV16WED FOR Fg CODE COi1fiPLIANCE neece8ed APPROVED sne" 15 Reinforced fabric scrim layer and top -ply thickness: Lends to?<<; . '�—� durable physical properties including:` ' • Long-term weathering, LIV resistance and heat -aging properties ClCity of Tukwila • High breaking and tearing strength Colors I 111 I' —, T UI Grey" Iite �---Flan* Optimized TPO formulation: delivers high-performance ozone resistance, cool roof reflectivrty and overall weather resistance. *Grey and tan are special order only. System Compatibility This product maybe used as a component in the following systems. Please reference product application for specific installation methods and information. l} g Do not use with Multi -Ply systems H Compadble with the selected Single Ply systems above Key: HA = Hot Applied CA = Cold Applied HW = Heat Weldable SA = Self Adhered MF = Mechanically Fastened FA = Fully Adhered BA = Ballasted 17— Energy and the Environment Installation/Application HL('iiI ' CITY OF TUhV1lILA Refer to the Safety Data Sheet and product label prior to using this product The Safety Data Sheet is available by calling 18001922-5922 or on the Web at vwwuim.com/roofing. 1WHO JVN 2 6 2015 Fully Adhered Mechanically Hot Air Weld Fastened pE R iti i i CENTER Refer to JM TPO application guides and detail drawings for instructions. Packaging and Dimensions Roll Width 10' (3.05 m) Roll Length 100' (30.48 m) Roll Coverage 1000 ftz (92.9 mz) Rolls per Pellet 6 Pallet Weight 2,303 lb (1,045 kg) Pallets perTruck* 16 Producing Location Scottsboro, AL •Assumes48' flatbed truck and does not reflect pallets of accessories or impact of mixed sizes. RS-MM 1.15 (Replaces 10-14) I � gg mL\Vj Fleece Backed Thermoplastic Pol olefin Membrane P Y Meets or exceeds the requirements of ASTM D 6878 Tested Physical Properties Breaking Strength, min, IV (N) D 751 220 (976) 499 (ZM) 450 (2,002) Elongation at Break, min % D 751 15 29 27 Tearing Strength, min, IV (N) D 751 45 (200) 91(404) 146 (649) Factory Seam Strength, min, Ibf (N) D 751 66 (290) 171(761) Thickness, min, in. D 751 +/ 10% from Nominal 0.060 (Nominal) Thickness Over Scrim, min, in. (mm) D 7635 0.015 0.027 (0.686) Water Absorption, max, % D 471 3.0 0.08 Brittleness Point, max, -40'F D 2137 No Cracks Pass Properties after Heat Aging @ 240°F D 573 Pass/Fail Pass Breaking Strength, % (after aging) D 751 90 >90 >90 a Elongation, % (after aging) 0751 90 >90 >90 € Tearing Strength, % (after aging) D 751 60 >60 >60 d Weight Change, max, % (after aging) D 751 ±1.0 0.25 Linear Dimensional Change, max, % (after 6 hrs @ 158°F) D 1204 ±1.0 42 Accelerated Weathering, min G 151 & G 155 10,080 kj/mz•nm @ 340 nm (4,000 hrs @ 0.70 W) 10,080 kj/mz (4,000 hrs) Cracking (@7x magnification) G 155 No Cracks Pass 1. JM TPO FB 115 is comprised of a 60 Mil TPO membrane and an integral fleece backing. The given physical properties are based on the JM TPO 60 Mil membrane. MD=Machine Direction —XMD=Cross-Machine Direction Note: All data represents tested values. Supplemental Testing Dynamic Puncture D %35 N/A Pass @ 27.5 Joules Static Puncture D 5602 N/A Pass @ 44lb(20 kg) Reflectance C 1549 N/A 78% Emittance C 1371 N/A 0.87 Refer to the Safety Data Sheet and product label prior to using this product The Safety Data Sheet is available by calling (800) 922-5922 or on the Web at wwwjm.com/roofing. RS-8639 1-15 (Replaces 10.14) SM" !o►msMe MARKETING BULLETIN — Roofing Systems 71717th St tlenver,CO as raga)922.6922 -J--V*QOftg Bulletin Number: M10-004 Date: January 13, 2010 Distribution: External Johns Manville Introduces JM TPO FB 115 and JM TPO FB 135 Fleece -backed Membranes Single Ply Roofing Systems Johns Manville is proud to announce the introduction of fleece -backed TPO into the JM TPO product portfolio. The introduction of fleece -backed membranes enhances Johns Manville's premier TPO offering and confirms our commitment to our valued single ply customers. Membranes JM TPO FB 135 is a white, 80 mil membrane with an integral fleece backing. It is available in 10' wide by 50' long rolls. JM TPO FB 115 is a white, 60 mil membrane with an integral fleece backing. It is available in 10' wide by 100' long rolls. JM TPO FB 115 is an SPPI product with up to a six week lead time. Additionally, projects will be evaluated individually to ensure the performance and quality standards our customers have come to expect with our existing JM TPO line. Accessories Johns Manville also offers accessories for our fleece backed offering. Use the JM TPO Reinforced Cover Strip for stripping in end laps as well as the JM TPO Curb Flashing for vertical transitions. Stocking Fleece -backed products will be produced, stocked and shipped from our Scottsboro, Alabama manufacturing facility. In order to ensure the most consistent product and delivery possible, the Scottsboro facility will be the only location to stock and fill orders. Look for expanded product options and innovations in the coming months as we continue to make our fleece products another successful portion of our TPO portfolio. Thank you very much for your support and help as we continue to make the best TPO product on the market even better! TJ Stock Product Manager 1/7" Johns Manville Description JM TPO FB 115 thermoplastic polyolefin (TPO) membranes are rein- forced with a polyester fabric and integral polyester fleece backing. The membrane is designed for use in mechanically fastened and fully adhered roofing applications. Use Install JM TPO FB 115 Membranes in new, re -roof (tear -off) and re- cover roof constructions. In re-cover constructions, if the existing roof is sound, the single ply membrane can eliminate the cost of disposing the original roof. Colors White, Grey* and Tan* Standard Sizes Color White, Grey* and Tan* 10' x 100' (3.05 m x 30.48 m) * Grey and tan are special order only. Installation Since JM TPO FB 115 Membranes are thermoplastic, they can be rolled out onto the roof substrate and easily welded into one homo- geneous sheet using hot-air welding procedures. JM TPO FB 115 Membranes can be mechanically fastened or adhered to the structural roof deck. Application must be in accor- dance with JM Peak Advantage® Guarantee requirements, build- ing codes, published standard fastening patterns or adhesives recommendations. Install JM TPO FB 115 products in accordance with current JM TPO Applicator Guides or Detail Drawings. JM TPO FB 115"m Fleece Backed Roofing Membrane Approvals JM mechanically fastened and adhered TPO FB 115 roof systems are classified by UL® (Underwriters Laboratories Inc.) and FM Global (Factory Mutual). When searching in RoofNav for a specific approval, be sure to indicate the mil thickness desired, i.e., JM TPO FB. Energy and the Environment CRRC® Initial Reflectivity:0.77 Emissivity:0.87 California Pass Reflectivity:0.77 Emissivity:0.87 Title 24 ENERGY Initial Reflectivity:0.78 STAR® 3 Yr. Aged Reflectivity: 0.68 Cleaned 3 Yr. No LEED® SRI of 101 as tested by ASTM E 1980. Recycled Content: Postconsumer:0% Postindustrial:0% Producing Locations: Scottsboro, AL Results shown are for the initial reflectivity and emittance for white membranes unless indicated; emissivity values for California Title 24 are tested per ASTM C 1371; LEED emissivity values are tested per ASTM E 408. JM Peak Advantage Guarantees Enhanced guarantees are now available on certain systems for wind and puncture. Consult your local sales representative for more information aboutthe new Single Ply Guarantee Charges Requirements Guide for specific guarantee terms and costs. Product Mechanically Fastened or Fully Adhered JM TPO FB 115 15 or 20 year JM TPO FB 115 Membranes meet or exceed all of the requirements of ASTM D 6878? Tested Physical Properties Property ASTM ASTM Test Method Requirements Overall Sheet Thickness D 751 >0.039 in. 0.0 mm) Thickness of Coating Over Fabric Weather Side D 6878 >0.012 in. (.305 mm) Breaking Strength D 751 Elongation at Reinforcement Break D 751 Tearing Strength D 751 Brittleness Point D 2137 Ozone Resistance (no cracks) D 1149 Heat Aging (Pass/Fail) D 573 ** MD: Machine Direction XMD: Cross Machine Direction UM TPO FB 115 is comprised of a 60 Mil TPO membrane and an integral fleece backing The given physical properties are based on the JM TPO 60 Mil membrane. 60 Mil 0.060 in. (1.52 mm) 0.027 in. (.69 mm) MD** XMD** >220lbf (978 N) 325.83 Ibf (1,449.36 N) 335.73lbf (1,493.40 N) >15% 42.41% 34.93% >55 Ibf (245 N) 89.8 Ibf (339.45 N) 184.6 Ibf (821.14 N) -40*C (401) Pass @ -40°C (-40°F) 0 rating Pass Pass RS-8639 12-09 (Replaces 11-09) M117 Johns Manville JM TPO FB 115' (Cont'd) Fleece Backed Roofing Membrane JM TPO FB 115 Membranes meet or exceed all of the requirements of ASTM D 6878? Tested Physical Properties Property ASTM ASTM I Test Method Requirements 60 Mil MD** XMD** Post Heat Aged Breaking Strength D 751 >90% 328.14 Ibf (1,459.64 N) 334.16 Ibf (1,486.42 N) retained values I Post Heat Aged Elongation at Reinforcement Break D 751 >90% 39.10% 35.14% retained values Post Heat Aged Tearing Strength D 751 >60% 77.1 Ibf (342.96 N) 245.0 Ibf (1,089.81N) retained values Post Heat Aged Weight Change D 1204 ±1% max. <0.1 % Post Heat Aged Linear Dimension Change D 6878 ±1% max. <0.1%% Water Absorption 0471 ±3.0% max. I 02.20% Factory Seam Strength D 751 >66 Ibf (294 N) 140.48 Ibf (624.89 N) Post Xenon Visual Inspection D 6878 Pass Pass ** MD: Machine Direction XMD: Cross Machine Direction UM TPO FB 115 is comprised of a 60 Mil TPO membrane and an integral fleece backing. The given physical properties and supplemental testing are based on the JM TPO 60 Mil membrane. Supplemental Testina Property ASTM Test Method ASTM Requirements 60 Mil Dynamic Puncture D 5635 N/A 27.5 Joules Static Puncture D 5602 N/A Pass @ 44lb(20 kg) Reflectance C 1549 N/A 80.78% Emittance C 1371 N/A 0.86 Refer to the Material Safety Data Sheet prior to using JM TPO FB 115. Material Safety Data Sheet is available by calling (800) 922-5922 or on the Web at www.jm.com/roofing. RS-8639 12-09 (Replaces 11-09) 0 117" Johns Manville Description JM TPO FB 135 thermoplastic polyolefin (TPO) membranes are rein- forced with a polyester fabric and integral polyester fleece backing. The membrane is designed for use in mechanically fastened and fully adhered roofing applications. Use Install JM TPO FB 135 Membranes in new, re -roof (tear -off) and re- cover roof constructions. In re-cover constructions, if the existing roof is sound, the single ply membrane can eliminate the cost of disposing the original roof. Colors White, Grey* and Tan* Standard Sizes Color White, Grey* and Tan* 10' x 100' (3.05 m x 30.48 m) * Grey and tan are special order only. Installation Since JM TPO FB 135 Membranes are thermoplastic, they can be rolled out onto the roof substrate and easily welded into one homo- geneous sheet using hot-air welding procedures. JM TPO FB 135 Membranes can be mechanically fastened or adhered to the structural roof deck. Application must be in accor- dance with JM Peak Advantage® Guarantee requirements, build- ing codes, published standard fastening patterns or adhesives recommendations. Install JM TPO FB 135 products in accordance with current JM TPO Applicator Guides or Detail Drawings. JM TPO FB 135" Fleece Backed Roofing Membrane Approvals JM mechanically fastened and adhered TPO FB 135 roof systems are classified by UL® (Underwriters Laboratories Inc.) and FM Global (Factory Mutual). When searching in RoofNav for a specific approval, be sure to indicate the mil thickness desired, i.e., JM TPO FB. Energy and the Environment CRRC® Initial Reflectivity:0.77 Emissivity:0.87 California Pass Reflectivity:0.77 Emissivity:0.87 Title 24 ENERGY Initial Reflectivity:0.78 STAR® 3 Yr. Aged Reflectivity: 0.68 Cleaned 3 Yr. No LEED® SRI of 101 as tested by ASTM E 1980. Recycled Content: Postconsumer:0% Postindustrial:0% Producing Locations: Scottsboro, AL Results shown are for the initial reflectivity and emittance for white membranes unless indicated; emissivity values for California Title 24 are tested per ASTM C 1371; LEED emissivity values are tested per ASTM E 408. JM Peak Advantage Guarantees Enhanced guarantees are now available on certain systems for wind and puncture. Consult your local sales representative for more information aboutthe new Single Ply Guarantee Charges Requirements Guide for specific guarantee terms and costs. Product Mechanically Fastened or Fully Adhered JM TPO FB 135 15 or 20 year JM TPO FB 135 Membranes meet or exceed all of the requirements of ASTM D 6878.1 Tested Physical Properties Property ASTM ASTM Test Method Requirements 80 Mil Overall Sheet Thickness Thickness of Coating Over Fabric Weather Side Breaking Strength Elongation at Reinforcement Break Tearing Strength Brittleness Point Ozone Resistance (no cracks) Heat Aging (Pass/Fail) D 751 D 6878 D 751 D 751 D 751 D 2137 D 1149 D 573 >0.039 in. (1.0 mm) >0.012 in. (.305 mm) >220 Ibf (978 N) >15% >55 Ibf (245 N) -40°C (-40°F) Pass 0.081 in. (2.05 mm) 0.035 in. (.889 mm) ±10% MD** XMD** 372 Ibf (1,655 N) 374 Ibf (1,664 N) 38.53% 35.75% 81.9 Ibf (364 N) 214 Ibf (952 N) Pass Q -40*C (-40°F) 0 rating Pass ** MD: Machine Direction XMD: Cross Machine Direction tJM TPO FB 135 is comprised of a 80 Mil TPO membrane and an integral fleece backing. The given physical properties are based on the JM TPO 80 Mil membrane. RS-8644 11.09 (New) Johns Manville I . '117" JM TPO FB 135TM (Cont'd) Fleece Backed Roofing Membrane JM TPO FB 135 Membranes meet or exceed all of the requirements of ASTM D 6878? Tested Physical Properties Property ASTM ASTM 80 Mil Test Method Requirements MD** XMD** Post Heat Aged Breaking Strength D 751 >90% 361 Ibf (1,606 N) 378 Ibf (1,681 N) retained values j Post Heat Aged Elongation at Reinforcement Break D 751 >90% 1 36.67% 34.29% retained values Post Heat Aged Tearing Strength D 751 >60% 80.4 Ibf (357.64 N) 192.6 Ibf (856.73 N) retained values Post Heat Aged Weight Change D 1204 ±1% max. <1% Post Heat Aged Linear Dimension Change D 6878 ±1 % max. <0% Water Absorption D 471 ±3.0% max. 1.4% Factory Seam Strength D 751 >66 Ibf (294 N) 96.33 Ibf (428.50 N) Post Xenon Visual Inspection D 6878 Pass Pass ** MD: Machine Direction XMD: Cross Machine Direction UM TPO FB 135 is comprised of a 80 Mil TPO membrane and an integral fleece backing. The given physical properties and supplemental testing are based on the JM TPO 80 Mil membrane. Supplemental Testing Property ASTM Test Method ASTM Requirements 80 Mil Dynamic Puncture D 5635 N/A 35 Joules Static Puncture D 5602 N/A Pass @ 44 lb (20 kg) Reflectance C 1549 N/A 81.52% Emittance C 1371 N/A 0.86 Refer to the Material Safety Data Sheet prior to using JM TPO FB 135. Material Safety Data Sheet is available by calling (800) 922-5922 or on the Web at www.im.com/roofing. RS-8644 11-09 (New) PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0159 DATE: 06/26/15 PROJECT NAME: ANDOVER EXECUTIVE PARK - 630 SITE ADDRESS: 630 INDUSTRY DR X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: W FM G All /� - - Building Division INFirePrevention Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 06/30/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved x Corrections Required ❑ (corrections entered in Reviews) Notation: DUE DATE: 07/28/15 Approved with Conditions Denied n (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 TECTA AMERICA SEATTLE LLr Page 1 of 3 Washington State Department of Labor & Industries TECTA AMERICA SEATTLE LLC Home Inicio em Espanol Contact Search L&I A-'L Index Help N v Secure I&I Safety Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 9500 AURORA AVE N SEATTLE, WA98103 Principals 206-522-5436 KRUSE, ERIN JANEANE KING County GRINAKER, MANAGER REGINELLI, DAVID R, MANAGER GRINAKER, KEVIN R, MANAGER SMITH, BRYNNE E, MANAGER (End: 06/02/2015) GRINAKER, STEVEN LYLE, MANAGER (End: 06/02/2015) KRACHT, TODD N, PARTNER/MEMBER (End: 06/24/2013) SONTACRONE,MARK F, PARTNER/MEMBER (End: 06/24/2013) FORBES, STEPHEN A, MANAGER (End: 06/24/2013) Doing business as TECTA AMERICA SEATTLE LLC WA UBI No. Business type 602 730 183 Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. TECTAAS905DH Effective — expiration 03/08/2010— 07/01/2017 Bond ................ XL SPECIALTY INS CO $12,000.00 Bond account no. US00069035SU15A Received by L&I Effective date 05/13/2015 06/22/2015 Expiration date Until Canceled Bond history Insurance ............................... https:Hsecure.lni.wa.gov/verify/Detail.aspx?UBI=602730183&LIC=TECTAAS905DH&SAW= 7/20/2015