DEVELOPMENT PERMIT
Parcel No: 0223400010 Permit Number: D15-0159
Address: 564 INDUSTRY DR Issue Date: 7/20/2015
Permit Expires On: 1/16/2016
Project Name: ANDOVER EXECUTIVE PARK - 564
Owner:
Name:
BLUE DOG PROPERTIES TRUST
Address:
PO BOX 847 C/O THOMSON REUTERS
PTS, CARLSBAD, WA, 92018
Contact Person:
Name:
STEVE STONE
Address:
9500 AURORA AVE N , SEATTLE, WA,
98103
Contractor:
Name:
TECTA AMERICA SEATTLE LLC
Address:
9500 AURORA AVE N , SEATTLE, WA,
98103
License No:
TECTAAS905DH
Phone: (206) 522-5436
Phone: (425) 881-9190
Expiration Date:
Lender:
Name: NCPW ANDOVER EXECUTIVE PARK
Address: 810 NW MARSHALL#300, PORTLAND,
OR, 97209
DESCRIPTION OF WORK:
OVER LAY THE EXISTING CAP SHEET ROOF WITH A SINGLE PLY TPO ROOF SYSTEM
Project Valuation: $40,132.00 Fees Collected: $1,441.34
Type of Fire Protection: Sprinklers:
Fire Alarm:
Type of Construction: Occupancy per IBC:
Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2012
National Electrical Code:
2014
International Residential Code Edition:
2012
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2012
WAC 296-46B:
2014
Uniform Plumbing Code Edition:
2012
WA State Energy Code:
2012
International Fuel Gas Code:
2012
Public Works Activities:
Channelization/Striping:
Curb Cut/Access/Sidewalk:
Fire Loop Hydrant:
Flood Control Zone:
Hauling/Oversize Load:
Land Altering: Volumes: Cut: 0 Fill: 0
Landscape Irrigation:
Sanitary Side Sewer: Number: 0
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter: No
LVAPermit Center Authorized Signature: '' W Date: 1
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:-64 Date:
Print Name:P�/�. �4
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: 'BUILDING PERMIT CONDITIONS'
2: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL"
0103 PRE-REROOF
CITY OF TUKWILA
Community Development Department
' Public Works Department
• Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.Izov
SITE LOCATION
Site Address: 564
Tenant Name:
Building Permit No. W1 J.
Project No.
Date Application Accepted:
Date Application Expires:
T�
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
"Please Print"
Dr Tukwila WA
PROPERTY OWNER
Name: Blue Dog Properties
Address: PO Box 847 C/O Thomson Reuters
City: PTS, Carlsbad State: WA Zip: 92018
CONTACT PERSON — person receiving all project
communication
Name: Steve Stone
Address: 9500 Aurora Ave N
City: Seattle State: wA Zip: 98103
Phone: (206) 455-7459 Fax: (206) 522-5472
Email: sstone@tectaamerica.com
GENERAL CONTRACTOR INFORMATION
Company Name: Tecta America Seattle LLC
Address: 9500 Aurora Ave N
City: Seattle State: WA Zip: 98103
Phone: (206) 522-5436 Fa": (206) 522-5472
Contr Reg No.: TECTAAS905DH Exp Date: 07/01/2017
Tukwila Business License No.: 43,s —o 9 yS'3
King Co Assessor's Tax
Suite Number: Floor:
New Tenant: ❑ .....Yes m ..No
ARCHITECT OF RECORD
Company Name: N/A
Architect Name:
Address:
City: State: Zip:
Phone: Fax:
Email:
ENGINEER OF RECORD
Company Name: N/A
Engineer Name:
Address:
City: State: Zip:
Phone: Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name: NCPW Andover Executive Park LL
Address: 810 NW Marshall #300
City: Portland State: OR Zip: 97209
H:\Applications\Forrtts-Applications On Line12011 ApplicationsTerntit Application Revised - 8-9-11.do"
Revised: August 2011 Page ] of 4
bh
BUILDING PERMIT INFORMATIO,. — 206-431-3670
Valuation of Project (contractor's bid price): $ 40,132 Existing Building Valuation: $
Describe the scope of work (please provide detailed information):
Over -lay the existing cap sheet roof with a single -ply TPO roof system
Will there be new rack storage? ❑..... Yes Z.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
I' Floor
2nd Floor
3r Floor
Floors thru
Basement
Accessory Structure"
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
'For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? El ....... Yes El ....... No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ ....... Sprinklers ❑ ....... Automatic Fire Alarm ❑ .......None ❑ .......Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ....... Yes ❑ .......No
If "yes, attach list ofmaterials and storage locations on a separate 8-112"x 11 "paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Wpplicetions\Forma-Applications On Line12011 ApplicationsTertnit Application Revised - 8-9-11.do«
Revised: August 2011 Page 2 of 4
bh
PUBLIC WORKS PERMIT INF074ATION — 206-433-0179
Scope of Work (please provide detailed information):
Call before you Dig: 811
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
❑ ...Tukwila ❑ ..: Water District # 125 ❑ .. Highline ❑ .. Renton
[]...Water Availability Provided
Sewer District
❑ ...Tukwila ❑ ... Valley View ❑ .. Renton ❑ .. Seattle
❑ ...Sewer Use Certificate ❑ ... Sewer Availability Provided
Septic System:
❑ On -site Septic System —For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted.with Application (mark boxes which ap
❑ ...Civil Plans (Maximum Paper Size — 22" x 34")
❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis
❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO)
❑ ...Hold Harmless — (ROW)
Proposed Activities (mark boxes that apply):
❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - Profit for less than 72 hours
❑ ...Right-of-way Use - No Disturbance ❑ .. Right-of-way Use — Potential Disturbance
❑ ...Construction/Excavation/Fill - Right-of-way ❑
Non Right-of-way ❑
❑ ...Total Cut cubic yards
❑ .. Work in Flood Zone
❑ ...Total Fill cubic yards
❑ .. Storm Drainage
❑ ...Sanitary Side Sewer
❑ .. Abandon Septic Tank
❑ .. Grease Interceptor
❑ ...Cap or Remove Utilities
❑ .. Curb Cut
❑ .. Channelization
❑ ...Frontage Improvements
❑ .. Pavement Cut
❑ .. Trench Excavation
❑ ...Traffic Control
❑ .. Looped Fire Line
❑ .. Utility Undergrounding
❑ ...Backflow Prevention - Fire Protection
"
Irrigation
"
Domestic Water
"
❑ ...Permanent Water Meter Size...
WO #
❑ ...Temporary Water Meter Size..
WO #
❑ ...Water Only Meter Size............
WO # ❑... Deduct
Water Meter Size "
❑ ...Sewer Main Extension.............Public
❑ Private ❑
❑ ...Water Main Extension.............Public
❑ Private ❑
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment
Monthly Service Billing to:
Name: Day Telephone:
Mailing Address:
City State Zip
Water Meter Refund/Billing:
Name: Day Telephone:
Mailing Address:
City State Zip
H:WpplicatiomkForms-Applications On Line\2011 ApplicationsTermit Application Revised - 8-9-Il.docx
Revised: August 2011 Page 3 of 4
bb
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Print Name: A e ;t zw e-
Mailing
Day Telephone:
City
Date:
State Zip
H: ApplicationsTom Applications On Line\2011 ApplicationsTermit Application Revised - 8-9-11.docx
Revised: August 2011 Page 4 of 4
bh
DESCRIPTIONS
PermitTRAK $5,946.66
D15-0158 Address: 742 INDUSTRY DR Apn: 2523049008 $2,559.00
DEVELOPMENT $2,483.87
PERMIT FEE
R000.322.100.00.00
0.00
$1,502.65
PLAN CHECK FEE
R000.345.830.00.00
0.00
$976.72
WASHINGTON STATE SURCHARGE
B640.237.114
0.00
$4.50
TECHNOLOGY FEE $75.13
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$75.13
D15-0159 Address: 564 INDUSTRY DR Apn: 0223400010 $1,441.34
DEVELOPMENT $1,399.08
PERMIT FEE
R000.322.100.00.00
0.00
$845.20
PLAN CHECK FEE
R000.345.830.00.00
0.00
$549.38
WASHINGTON STATE SURCHARGE
B640.237.114
0.00
$4.50
TECHNOLOGY FEE $42.26
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$42.26
D15-0160 Address: 630 INDUSTRY DR Apn: 2523049008 $1,946.32
DEVELOPMENT $1,889.21
PERMIT FEE
R000.322.100.00.00
0.00
$1,142.25
PLAN CHECK FEE
R000.345.830.00.00
0.00
$742.46
WASHINGTON STATE SURCHARGE
B640.237.114
0.00
$4.50
TECHNOLOGY FEE $57.11
TECHNOLOGY FEE R000.322.900.04.00 0.00 $57.11
�TOTAL FEES PAID BY RECEIPT: R5615 . .
Date Paid: Friday, June 26, 2015
Paid By: STEVE GRINAKER
Pay Method: CREDIT CARD 08327G
Printed: Friday, June 26, 2015 9:06 AM 1 of 1 Ow" SYSTEMS
WW—
.
INSPECTION RECORD ,his 6 1� Retain a copy with per
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Pro'ect
IC46' .�
Type of Inection::
y&
Address:
Date Called:
Special Instructions: ff
Date Wanted: a.m.
7-ZS—%' p.m.
Requester:
Phone No:
Approved per applicable codes. 1-1 Corrections required prior to approval.
M ENTS:
U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
SEPARATE PERMIT
RE -SQUIRED FOR:
I"lectr1w
R mbing
Gas Piping
City of Tukwilai
�i�Il..d~i'LG DIVISION
REVISIONS
No changes shall he made to the scope
of work without prior approval of
Tukwila Building Division.
ROTE: Revisions will require a new plan submittal
and may include additional plan review fees.
COPY
Z ,
Permit NO, 0 IS
Plan review oM is sul*d to WV and ombsiam.
APP of construction documents dM not auduwritte
the violation of any adopted cob orondnm, Receipt
Of approved Field ns is actmawledged:
Date: Z5—
City of Tukwila
BUILDING DIVISION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUL 15 2015
tTcity of Tukwila
BUILDING DIVISION
A
a
J
cc
w -Y
Lr)
N
W
~
>�
�
w
U
U
Lu
N
m
t
g
W
Q
FOR
)r:--- COII��hPLIANCE
'I I
JUL 15 2015
i
Co
N
Standard
Reflectivfty.
Emissivity.
CRRC®
Initial
0.77
0.87
3 Yr. Aged
0.70
0.86
CA Title 24
Pass
0.77
0.87
ENERGY STAR®
Initial
0.78
0.87
3 Yr. Aged
0.68
Not Tested
LEED®
SRI
101
Recycled Content
Post -consumer. 0%
Post-industrial: 5 /o
Results shown are for the initial reflectivity and emittance for white membranes unless
otherwise indicated; emissivity values for California Tide 24 are tested per ASTM C 1371;
LEED emissivity values are tested per ASTM E 408.
Peak Advantage' Guarantee Information
Product Guarantee Term
JM TPO FB 115 15 or 20 years
Codes and Approvals
$ un
P
CII M aml-0ode Coty APPROVED Product C.ArM App—d
FILE
Fleece Backed Thermoplastic
Meets or exceeds the requirements of ASTM D 6878
Features and Components
Integral Polyester Fleece Backing: In -line application of fleece
allows for stronger bond for polyester backing that gives more
flexibility in varying substrates for mechanically fastened or
adhered systems.
One of the Widest Melt Windows: Promotes better welds over a
wider variety of speeds and temperatures, and leads to a softer,
more flexible and workable sheet
JINl IN }8115.
Polyolefin Membrane
CORWIent
x: M
�— - TM
REV16WED FOR Fg
CODE COi1fiPLIANCE neece8ed
APPROVED sne"
15
Reinforced fabric scrim layer and top -ply thickness: Lends to?<<; . '�—�
durable physical properties including:` '
• Long-term weathering, LIV resistance and heat -aging properties ClCity of Tukwila
• High breaking and tearing strength Colors I 111 I' —, T UI
Grey" Iite �---Flan*
Optimized TPO formulation: delivers high-performance ozone
resistance, cool roof reflectivrty and overall weather resistance. *Grey and tan are special order only.
System Compatibility This product maybe used as a component in the following systems. Please reference product application for specific installation methods and information.
l}
g Do not use with Multi -Ply systems H Compadble with the selected Single Ply systems above
Key: HA = Hot Applied CA = Cold Applied HW = Heat Weldable SA = Self Adhered MF = Mechanically Fastened FA = Fully Adhered BA = Ballasted
17—
Energy and the Environment Installation/Application HL('iiI '
CITY OF TUhV1lILA
Refer to the Safety Data Sheet and product label prior to using this product
The Safety Data Sheet is available by calling 18001922-5922 or on the Web at
vwwuim.com/roofing.
1WHO JVN 2 6 2015
Fully Adhered Mechanically Hot Air Weld Fastened pE R iti i i CENTER
Refer to JM TPO application guides and detail drawings
for instructions.
Packaging and Dimensions
Roll Width
10' (3.05 m)
Roll Length
100' (30.48 m)
Roll Coverage
1000 ftz (92.9 mz)
Rolls per Pellet
6
Pallet Weight
2,303 lb (1,045 kg)
Pallets perTruck*
16
Producing Location
Scottsboro, AL
•Assumes48' flatbed truck and does not reflect pallets of accessories or impact of mixed sizes.
RS-MM 1.15 (Replaces 10-14)
I �
gg mL\Vj Fleece Backed Thermoplastic Pol olefin Membrane
P Y
Meets or exceeds the requirements of ASTM D 6878
Tested Physical Properties
Breaking Strength, min, IV (N)
D 751
220 (976)
499 (ZM)
450 (2,002)
Elongation at Break, min %
D 751
15
29
27
Tearing Strength, min, IV (N)
D 751
45 (200)
91(404)
146 (649)
Factory Seam Strength, min, Ibf (N)
D 751
66 (290)
171(761)
Thickness, min, in.
D 751
+/ 10% from Nominal
0.060 (Nominal)
Thickness Over Scrim, min, in. (mm)
D 7635
0.015
0.027 (0.686)
Water Absorption, max, %
D 471
3.0
0.08
Brittleness Point, max, -40'F
D 2137
No Cracks
Pass
Properties after Heat Aging @ 240°F
D 573
Pass/Fail
Pass
Breaking Strength, % (after aging)
D 751
90
>90
>90
a
Elongation, % (after aging)
0751
90
>90
>90
€
Tearing Strength, % (after aging)
D 751
60
>60
>60
d
Weight Change, max, % (after aging)
D 751
±1.0
0.25
Linear Dimensional Change, max, % (after 6 hrs @ 158°F)
D 1204
±1.0
42
Accelerated Weathering, min
G 151 & G 155
10,080 kj/mz•nm @ 340 nm
(4,000 hrs @ 0.70 W)
10,080 kj/mz
(4,000 hrs)
Cracking (@7x magnification)
G 155
No Cracks
Pass
1. JM TPO FB 115 is comprised of a 60 Mil TPO membrane and an integral fleece backing.
The given physical properties are based on the JM TPO 60 Mil membrane.
MD=Machine Direction
—XMD=Cross-Machine Direction
Note: All data represents tested values.
Supplemental Testing
Dynamic Puncture
D %35
N/A
Pass @ 27.5 Joules
Static Puncture
D 5602
N/A
Pass @ 44lb(20 kg)
Reflectance
C 1549
N/A
78%
Emittance
C 1371
N/A
0.87
Refer to the Safety Data Sheet and product label prior to using this product
The Safety Data Sheet is available by calling (800) 922-5922 or on the Web at
wwwjm.com/roofing. RS-8639 1-15 (Replaces 10.14)
SM"
!o►msMe
MARKETING BULLETIN — Roofing Systems
71717th St
tlenver,CO as
raga)922.6922
-J--V*QOftg
Bulletin Number: M10-004
Date: January 13, 2010
Distribution: External
Johns Manville Introduces JM TPO FB 115 and JM TPO FB 135
Fleece -backed Membranes
Single Ply Roofing Systems
Johns Manville is proud to announce the introduction of fleece -backed TPO into the
JM TPO product portfolio. The introduction of fleece -backed membranes enhances
Johns Manville's premier TPO offering and confirms our commitment to our valued
single ply customers.
Membranes
JM TPO FB 135 is a white, 80 mil membrane with an integral fleece backing. It is
available in 10' wide by 50' long rolls.
JM TPO FB 115 is a white, 60 mil membrane with an integral fleece backing. It is
available in 10' wide by 100' long rolls.
JM TPO FB 115 is an SPPI product with up to a six week lead time. Additionally,
projects will be evaluated individually to ensure the performance and quality
standards our customers have come to expect with our existing JM TPO line.
Accessories
Johns Manville also offers accessories for our fleece backed offering. Use the JM
TPO Reinforced Cover Strip for stripping in end laps as well as the JM TPO Curb
Flashing for vertical transitions.
Stocking
Fleece -backed products will be produced, stocked and shipped from our Scottsboro,
Alabama manufacturing facility. In order to ensure the most consistent product and
delivery possible, the Scottsboro facility will be the only location to stock and fill
orders.
Look for expanded product options and innovations in the coming months as we
continue to make our fleece products another successful portion of our TPO portfolio.
Thank you very much for your support and help as we continue to make the best TPO
product on the market even better!
TJ Stock
Product Manager
1/7"
Johns Manville
Description
JM TPO FB 115 thermoplastic polyolefin (TPO) membranes are rein-
forced with a polyester fabric and integral polyester fleece backing.
The membrane is designed for use in mechanically fastened and
fully adhered roofing applications.
Use
Install JM TPO FB 115 Membranes in new, re -roof (tear -off) and re-
cover roof constructions. In re-cover constructions, if the existing
roof is sound, the single ply membrane can eliminate the cost of
disposing the original roof.
Colors
White, Grey* and Tan*
Standard Sizes
Color
White, Grey* and Tan* 10' x 100' (3.05 m x 30.48 m)
* Grey and tan are special order only.
Installation
Since JM TPO FB 115 Membranes are thermoplastic, they can be
rolled out onto the roof substrate and easily welded into one homo-
geneous sheet using hot-air welding procedures.
JM TPO FB 115 Membranes can be mechanically fastened or
adhered to the structural roof deck. Application must be in accor-
dance with JM Peak Advantage® Guarantee requirements, build-
ing codes, published standard fastening patterns or adhesives
recommendations. Install JM TPO FB 115 products in accordance
with current JM TPO Applicator Guides or Detail Drawings.
JM TPO FB 115"m
Fleece Backed Roofing Membrane
Approvals
JM mechanically fastened and adhered TPO FB 115 roof systems are
classified by UL® (Underwriters Laboratories Inc.) and FM Global
(Factory Mutual). When searching in RoofNav for a specific approval,
be sure to indicate the mil thickness desired, i.e., JM TPO FB.
Energy and the Environment
CRRC®
Initial Reflectivity:0.77 Emissivity:0.87
California
Pass Reflectivity:0.77 Emissivity:0.87
Title 24
ENERGY
Initial Reflectivity:0.78
STAR®
3 Yr. Aged Reflectivity: 0.68
Cleaned 3 Yr. No
LEED®
SRI of 101 as tested by ASTM E 1980.
Recycled Content:
Postconsumer:0% Postindustrial:0%
Producing Locations: Scottsboro, AL
Results shown are for the initial reflectivity and emittance for white membranes unless
indicated; emissivity values for California Title 24 are tested per ASTM C 1371; LEED
emissivity values are tested per ASTM E 408.
JM Peak Advantage Guarantees
Enhanced guarantees are now available on certain systems for
wind and puncture. Consult your local sales representative for
more information aboutthe new Single Ply Guarantee Charges
Requirements Guide for specific guarantee terms and costs.
Product Mechanically Fastened or Fully Adhered
JM TPO FB 115 15 or 20 year
JM TPO FB 115 Membranes meet or exceed all of the requirements of ASTM D 6878?
Tested Physical Properties
Property ASTM ASTM
Test Method Requirements
Overall Sheet Thickness D 751 >0.039 in. 0.0 mm)
Thickness of Coating Over Fabric Weather Side D 6878 >0.012 in. (.305 mm)
Breaking Strength
D 751
Elongation at Reinforcement Break
D 751
Tearing Strength
D 751
Brittleness Point
D 2137
Ozone Resistance (no cracks)
D 1149
Heat Aging (Pass/Fail)
D 573
** MD: Machine Direction
XMD: Cross Machine Direction
UM TPO FB 115 is comprised of a 60 Mil TPO membrane and an integral fleece backing
The given physical properties are based on the JM TPO 60 Mil membrane.
60 Mil
0.060 in. (1.52 mm)
0.027 in. (.69 mm)
MD** XMD**
>220lbf (978 N) 325.83 Ibf (1,449.36 N) 335.73lbf (1,493.40 N)
>15% 42.41% 34.93%
>55 Ibf (245 N) 89.8 Ibf (339.45 N) 184.6 Ibf (821.14 N)
-40*C (401) Pass @ -40°C (-40°F)
0 rating
Pass Pass
RS-8639 12-09 (Replaces 11-09)
M117
Johns Manville
JM TPO FB 115' (Cont'd)
Fleece Backed Roofing Membrane
JM TPO FB 115 Membranes meet or exceed all of the requirements of ASTM D 6878?
Tested Physical Properties
Property
ASTM
ASTM
I
Test Method
Requirements
60 Mil
MD**
XMD**
Post Heat Aged Breaking Strength
D 751
>90%
328.14 Ibf (1,459.64 N)
334.16 Ibf (1,486.42 N)
retained values
I
Post Heat Aged Elongation at Reinforcement Break
D 751
>90%
39.10%
35.14%
retained values
Post Heat Aged Tearing Strength
D 751
>60%
77.1 Ibf (342.96 N)
245.0 Ibf (1,089.81N)
retained values
Post Heat Aged Weight Change
D 1204
±1% max.
<0.1 %
Post Heat Aged Linear Dimension Change
D 6878
±1% max.
<0.1%%
Water Absorption
0471
±3.0% max.
I 02.20%
Factory Seam Strength
D 751
>66 Ibf (294 N)
140.48 Ibf (624.89 N)
Post Xenon Visual Inspection
D 6878
Pass
Pass
** MD: Machine Direction
XMD: Cross Machine Direction
UM TPO FB 115 is comprised of a 60 Mil TPO membrane and an integral
fleece backing. The
given physical properties and supplemental testing are based on the JM TPO 60 Mil
membrane.
Supplemental Testina
Property
ASTM
Test Method
ASTM
Requirements
60 Mil
Dynamic Puncture
D 5635
N/A
27.5 Joules
Static Puncture
D 5602
N/A
Pass @ 44lb(20 kg)
Reflectance
C 1549
N/A
80.78%
Emittance
C 1371
N/A
0.86
Refer to the Material Safety Data Sheet prior to using JM TPO
FB 115. Material Safety Data Sheet is available by calling
(800) 922-5922 or on the Web at www.jm.com/roofing.
RS-8639 12-09 (Replaces 11-09)
0
117"
Johns Manville
Description
JM TPO FB 135 thermoplastic polyolefin (TPO) membranes are rein-
forced with a polyester fabric and integral polyester fleece backing.
The membrane is designed for use in mechanically fastened and
fully adhered roofing applications.
Use
Install JM TPO FB 135 Membranes in new, re -roof (tear -off) and re-
cover roof constructions. In re-cover constructions, if the existing
roof is sound, the single ply membrane can eliminate the cost of
disposing the original roof.
Colors
White, Grey* and Tan*
Standard Sizes
Color
White, Grey* and Tan* 10' x 100' (3.05 m x 30.48 m)
* Grey and tan are special order only.
Installation
Since JM TPO FB 135 Membranes are thermoplastic, they can be
rolled out onto the roof substrate and easily welded into one homo-
geneous sheet using hot-air welding procedures.
JM TPO FB 135 Membranes can be mechanically fastened or
adhered to the structural roof deck. Application must be in accor-
dance with JM Peak Advantage® Guarantee requirements, build-
ing codes, published standard fastening patterns or adhesives
recommendations. Install JM TPO FB 135 products in accordance
with current JM TPO Applicator Guides or Detail Drawings.
JM TPO FB 135"
Fleece Backed Roofing Membrane
Approvals
JM mechanically fastened and adhered TPO FB 135 roof systems are
classified by UL® (Underwriters Laboratories Inc.) and FM Global
(Factory Mutual). When searching in RoofNav for a specific approval,
be sure to indicate the mil thickness desired, i.e., JM TPO FB.
Energy and the Environment
CRRC®
Initial Reflectivity:0.77 Emissivity:0.87
California
Pass Reflectivity:0.77 Emissivity:0.87
Title 24
ENERGY
Initial Reflectivity:0.78
STAR®
3 Yr. Aged Reflectivity: 0.68
Cleaned 3 Yr. No
LEED®
SRI of 101 as tested by ASTM E 1980.
Recycled Content:
Postconsumer:0% Postindustrial:0%
Producing Locations: Scottsboro, AL
Results shown are for the initial reflectivity and emittance for white membranes unless
indicated; emissivity values for California Title 24 are tested per ASTM C 1371; LEED
emissivity values are tested per ASTM E 408.
JM Peak Advantage Guarantees
Enhanced guarantees are now available on certain systems for
wind and puncture. Consult your local sales representative for
more information aboutthe new Single Ply Guarantee Charges
Requirements Guide for specific guarantee terms and costs.
Product Mechanically Fastened or Fully Adhered
JM TPO FB 135 15 or 20 year
JM TPO FB 135 Membranes meet or exceed all of the requirements of ASTM D 6878.1
Tested Physical Properties
Property ASTM ASTM
Test Method Requirements
80 Mil
Overall Sheet Thickness
Thickness of Coating Over Fabric Weather Side
Breaking Strength
Elongation at Reinforcement Break
Tearing Strength
Brittleness Point
Ozone Resistance (no cracks)
Heat Aging (Pass/Fail)
D 751
D 6878
D 751
D 751
D 751
D 2137
D 1149
D 573
>0.039 in. (1.0 mm)
>0.012 in. (.305 mm)
>220 Ibf (978 N)
>15%
>55 Ibf (245 N)
-40°C (-40°F)
Pass
0.081 in. (2.05 mm)
0.035 in. (.889 mm) ±10%
MD**
XMD**
372 Ibf (1,655 N)
374 Ibf (1,664 N)
38.53%
35.75%
81.9 Ibf (364 N)
214 Ibf (952 N)
Pass Q -40*C (-40°F)
0 rating
Pass
** MD: Machine Direction
XMD: Cross Machine Direction
tJM TPO FB 135 is comprised of a 80 Mil TPO membrane and an integral fleece backing.
The given physical properties are based on the JM TPO 80 Mil membrane.
RS-8644 11.09 (New)
Johns Manville
I . '117"
JM TPO FB 135TM (Cont'd)
Fleece Backed Roofing Membrane
JM TPO FB 135 Membranes meet or exceed all of the requirements of ASTM D 6878?
Tested Physical Properties
Property
ASTM
ASTM
80 Mil
Test Method
Requirements
MD**
XMD**
Post Heat Aged Breaking Strength
D 751
>90%
361 Ibf (1,606 N)
378 Ibf (1,681 N)
retained values j
Post Heat Aged Elongation at Reinforcement Break
D 751
>90% 1
36.67%
34.29%
retained values
Post Heat Aged Tearing Strength
D 751
>60%
80.4 Ibf (357.64 N)
192.6 Ibf (856.73 N)
retained values
Post Heat Aged Weight Change
D 1204
±1% max.
<1%
Post Heat Aged Linear Dimension Change
D 6878
±1 % max.
<0%
Water Absorption
D 471
±3.0% max.
1.4%
Factory Seam Strength
D 751
>66 Ibf (294 N)
96.33 Ibf (428.50 N)
Post Xenon Visual Inspection
D 6878
Pass
Pass
** MD: Machine Direction
XMD: Cross Machine Direction
UM TPO FB 135 is comprised of a 80 Mil TPO membrane and an integral
fleece backing. The
given physical properties
and supplemental testing are based on the JM TPO 80 Mil
membrane.
Supplemental Testing
Property
ASTM
Test Method
ASTM
Requirements
80 Mil
Dynamic Puncture
D 5635
N/A
35 Joules
Static Puncture
D 5602
N/A
Pass @ 44 lb (20 kg)
Reflectance
C 1549
N/A
81.52%
Emittance
C 1371
N/A
0.86
Refer to the Material Safety Data Sheet prior to using JM TPO
FB 135. Material Safety Data Sheet is available by calling
(800) 922-5922 or on the Web at www.im.com/roofing.
RS-8644 11-09 (New)
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D15-0159
DATE: 06/26/15
PROJECT NAME: ANDOVER EXECUTIVE PARK - 630
SITE ADDRESS: 630 INDUSTRY DR
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
W FM G All /� - -
Building Division INFirePrevention Planning Division ❑
Public Works ❑ Structural ❑ Permit Coordinator ❑
PRELIMINARY REVIEW: DATE: 06/30/15
Not Applicable ❑ Structural Review Required ❑
(no approval/review required)
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
x
Corrections Required ❑
(corrections entered in Reviews)
Notation:
DUE DATE: 07/28/15
Approved with Conditions
Denied n
(ie: Zoning Issues)
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
TECTA AMERICA SEATTLE LLr
Page 1 of 3
Washington State Department of
Labor & Industries
TECTA AMERICA SEATTLE LLC
Home Inicio em Espanol Contact Search L&I
A-'L Index Help N v Secure I&I
Safety Claims & Insurance Workplace Rights Trades & Licensing
Owner or tradesperson 9500 AURORA AVE N
SEATTLE, WA98103
Principals 206-522-5436
KRUSE, ERIN JANEANE KING County
GRINAKER, MANAGER
REGINELLI, DAVID R, MANAGER
GRINAKER, KEVIN R, MANAGER
SMITH, BRYNNE E, MANAGER
(End: 06/02/2015)
GRINAKER, STEVEN LYLE, MANAGER
(End: 06/02/2015)
KRACHT, TODD N, PARTNER/MEMBER
(End: 06/24/2013)
SONTACRONE,MARK
F, PARTNER/MEMBER
(End: 06/24/2013)
FORBES, STEPHEN A, MANAGER
(End: 06/24/2013)
Doing business as
TECTA AMERICA SEATTLE LLC
WA UBI No. Business type
602 730 183 Limited Liability Company
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
TECTAAS905DH
Effective — expiration
03/08/2010— 07/01/2017
Bond
................
XL SPECIALTY INS CO
$12,000.00
Bond account no.
US00069035SU15A
Received by L&I
Effective date
05/13/2015
06/22/2015
Expiration date
Until Canceled
Bond history
Insurance
...............................
https:Hsecure.lni.wa.gov/verify/Detail.aspx?UBI=602730183&LIC=TECTAAS905DH&SAW= 7/20/2015