HomeMy WebLinkAboutPermit D15-0216 - COTTAGE CREEK CONDOS - ROOF AND STRUCTURE REPAIRCOTTAGE CREEK CONDOS AA, -90MA'I'Ll 15344 62 AVE S D15-0216 City of Tukwila • Department of Community Development « 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT Parcel No: 1770500000 Permit Number: D15-0216 Address: 15344 62ND AVE S Issue Date: 1/7/2016 Permit Expires On: 7/5/2016 Project Name: COTTAGE CREEK CONDOS - CARPORT Owner: Name: Address: WA, Contact Person: Name: STEPHEN TAPP Address: 2330 E MADISON ST, SEATTLE, WA, 98112 Contractor: Name: D & J CUSTOM METAL FAB INC Address: 11615 12TH AVE S , SEATTLE, WA, 98168 License No: DJCUSMF011MH Lender: Name: COTTAGE CREEK CONDOMINIUM ASSO Address: PO BOX 88344, TUKWILA, WA, 98138 DESCRIPTION OF WORK: Phone: (206) 459-5151 Phone: (206) 242-3238 Expiration Date: 5/1/2016 REPLACE DAMAGED ROOF AND STRUCTURE ON EXISTING CARPORT Project Valuation: $15,000.00 Fees Collected: $657.82 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: VB Occupancy per IBC: U Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: cAAA Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Sign Prirr Date: — 1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: The special inspections and verifications for concrete construction shall be as required by IBC Chapter 17, Table 1705.3. S: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 6: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 7: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 8: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 9: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 10: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 11: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 12: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 14: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. 15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 0201 FOOTING 0409 FRAMING 0401 ROOF SHEATHING 4027 SI-COLD-FORM WELD 4000 SI-CONCRETE CONST 4034 SI-METAL PLATE CONN 4028 SI-REINF STEEL -WELD 4025 SI-STEEL CONST 4026 SI-STRUCT STEEL 4004 SI-WELDING CITY OF TUKWILA • ,i �� Community Development Department Public Works Department ' Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httv://ivww.TukwilaWA.gov Building Permit No.�_� Project No. Date Application Accepted: Date Application Expires: use CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION 15372,15374,15376,15378 62nd. Ave. South, Tukwila, Wa. 98188 1770500000 UNITS 15372,15374,15376,15378 King Co Assessor's Tax No.: Site Address: 62nd. AVENUE SOUTH Suite Number: Floor: Tenant Name: Cottage Creek Condo Association New Tenant: ❑ ..... Yes ®.. No PROPERTY OWNER Name: Board President - Shana Kirby Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Stephen Tapp Address: 2330 East Madison Street City: Seattle State: Wa. Zip: 98112 Phone: 206-459-5151 Fax: Email: archeng2330@gmaii.com GENERAL CONTRACTOR INFORMATION Company Name: D&J Custom Metal Fabricators Address: 11615 - 12th Avenue South City: Seattle State: Wa. Zip: 98168 Phone: 206-242-3238 Fax: Contr Reg No.: DJCUSMF11 Exp Date: 4/16/16 Tukwila Business License No.: ARCHITECT OF RECORD Company Name: Stephen Tapp Architect/P.E. Architect Name: Stephen Tapp Address: 2330 East Madison Street City: Seattle State: Wa. Zip: 98112 Phone: 206-459-5151 Fax: Email: archeng2330@gmaii.com ENGINEER OF RECORD Company Name: Stephen Tapp Architect/P.E. Engineer Name: Stephen Tapp Address: 2330 East Madison Street City: Seattle State: Wa. Zip: 98112 Phone: 206459-5151 Fax: Email: archeng2330@gmail.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: /' O Address: ca ,3 ,j"t- 5 S r o City: State: Zip: P1 • H:\Applications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page I of 4 BUILDING PERMIT INFORMATII - 206-431-3670 Valuation of Project (contractor's bid price): $ 15,000 Existing Building Valuation: $ 250 Describe the scope of work (please provide detailed information): REPLACE DAMAGED ROOF AND STRUCTURE ON EXISTING CARPORT Will there be new rack storage? ❑ .... Yes O ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I' Floor 2" Floor P Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage 720 SQ.FT. to be 720 SQ.FT. lIB U Attached Carport demolished Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: NIA Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 2 Compact: Handicap: Will there be a change in use? ❑....... Yes ®.......No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ .......Sprinklers El Automatic Fire Alarm ®....... None - El ....... Other (specify) Will there be storage or use of flammable; combustible or hazardous materials in the building? ❑ .......Yes ❑ ...... No .If `yes', attach list of materials and storage locations on a separate 8-112"x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. li:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised . 2-7-12.doex Revised: February 2012 Page 2 of 4 - I PUBLIC WORKS PERMIT INFGjL ATION — 206-433-0179 Scope of Work (please provide detailed information): N/A Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ®..Tukwila ❑... Water District #125 ❑... Highline El ... Renton ❑ .. Water Availability Provided Sewer District ® ..Tukwila El ...Valley View ❑... Renton El ... Seattle ❑ .. Sewer Use Certificate ❑ ...Sewer Availability Provided N/A Septic System: El On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. N/A Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 2211 x 34") ❑ .. Technical Information Report (Storm Drainage) El ... Geotechnical Report ❑ .. Traffic Impact Analysis ❑ .. Bond El ... Insurance El ... Easement(s) El ... Maintenance Agreement(s) El.. Hold Harmless — (SAO) .. Hold Harmless — (ROW) N/A Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑... Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance El ... Right-of-way Use — Potential Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ N/A ❑ .. Total Cut cubic yards ❑ .. Total Fill cubic yards ❑ .. Sanitary Side Sewer ❑ .- Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑... Work in Flood Zone El ... Storm Drainage El ... Abandon Septic Tank ❑... Curb Cut El ... Pavement Cut ... Looped Looped Fire Line ❑ ... Grease Interceptor El ... Channelization ❑... Trench Excavation El ... Utility Undergrounding ❑ .. Permanent Water Meter Size (1) WO # (2) " WO # (3) ❑ .. Temporary Water Meter Size (1) WO # (2) " WO # (3) ❑ .. Water Only Meter Size........... WO # ❑ .. Deduct Water Meter Size _ ❑ .. Sewer Main Extension............ Public ❑ Private ❑ ❑ .. Water Main Extension............ Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Mailing Water Meter Refund/Billing: Day Telephone: City Day Telephone: WO# WO# State Zip Mailing City State Zip H:Wpplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx ReviwA Felm— 2017 Pape 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR Signature: Stephen Print Name: Mailing Address: 2330 East Madison Street 8/21 /15 Day Telephone: 206-459-5151 Seattle, Wa. 98122 City State Zip H:1Applications\Forms-Applications On Line12012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page 4 of 4 DESCRIPTIONS PermitTRAK ACCOUNTQUANTITY PAID $716.08 D15-0216 Address: 15344 62ND AVE S Apn: 1770500000 $408.02 DEVELOPMENT $388.80 PERMIT FEE R000.322.100.00.00 0.00 $384.30 WASHINGTON STATE SURCHARGE 13640.237.114 0.00 $4.50 TECHNOLOGY FEE $19.22 TECHNOLOGY FEE R000.322.900.04.00 0.00 $19.22 D15-0275 Address: 15344 62ND AVE S BLDG A Apn: 1770500000 $308.06 DEVELOPMENT $308.06 PERMIT FEE TOTAL PAID RECEIPT: • R000.322.100.00.00 0.00 $308.06 $716.08 Date Paid: Thursday, January 07, 2016 Paid By: D & J CUSTOM METAL FABRICATION Pay Method: CHECK 1834 Printed: Thursday, January 07, 2016 1:43 PM 1 of 1 OR SYSTEMS Date Paid: Tuesday, August 25, 2015 Paid By: COTTAGE CREEK CONDOMINIUM ASSO Pay Method: CHECK 2963 Printed: Thursday, January 07, 2016 2:11 PM 1 of 1 CRW SY57EMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36771 Permit Inspection Request Line (206) 438-9350 Pro„(ect� � f'��� V�d l Type ofln ection f, � v' A dress: 12 q 4 6 r of e Date Call .. Speciaall Instructions: �1 e 4/0'�'° Date Wanted: a.m. p.m. Requester: - Phone No: � - -7 3 Inspector: 4L- I Date .>-6 114 El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. M INSPECTION RECORD Retain a copy with permit �S �vI l ECTION NO. PERMIT NO. CITY OE TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: l o el � Type of Inspection: c r Address. Date Called: S—Pecigl Instructions: Y Date anted: a.m. Requester: ---F--'— Phone No: jInspector: V li / IDate—, REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Stephen Tapp Architect / P.E. 2330 East Madison Street Seattle, Washington 98112 (206)320-0534 Cell (206) 459-5151 April 22, 2016 Bill Rambo Department of Community Development 6300 Southcenter BLVD, Suite #100 Tukwila, Washington 98188 Project: Cottage Creek Condos Carport Replacement 15372,15374,15376,15378 62"" Avenue South Tukwila, Washington 98188 Building Permit Number: DI5-0216 Final Review of Installation: 4/22/16 Bill, My office has reviewed the final installation of the replacement structure for the above mentioned damaged carport rebuild. The installation of new materials, connections, and workmanship is in conformance with my structural design intent and the parameters 2012 IBC and is therefore approved as installed. Sincerely, Stephen Tapp RE V tV-W—ED FQR CODE APPROVED SEP 2 4 2015 CifyofTubft BUILDING DNqBMN Job Number: T15H3 August 2015 Code: 2012 IBC Stephen Tapp Architect/P.E. 2330 East Madison Street Seattle, Washington 98112 Office (206) 320-0534 Cell (206) 459-5151 FIL Engineering Calculations Steel Beam and Column Calculations Lateral Engineering Analysis for Seismic Loading for Damaged Carport Replacement Cottage Creek Condominiums 15372,15374,15376,15378 62nd. Avenue South Tukwila, Washington 98188 REVIEWED FOR COMPLIANCE RECEIVED WITH REQUIREMENTS OF THE CITY OF TUKWILA 2012 CODE CORRECTOW LTR# SEP 10 2015 PER 8/21/2015 1:52 PM - 1 -C2 • to T CENTER Loading Requirements ASCE 7-10 Codes 2012 IBC AISC/ASD Ninth Edition .ACI 11 NDS 2007 SEAW Rapid Solutions Methodology for Wind Design Wind Design Wind Speed = 90 mph Wind Exposure = `B' Soil Loads (assumed) No soils report available Assumed Soil Density =120 pcf Assumed Soil Bearing Pressure =1500 psf Building Loads Snow Load (SN) = 25 psf Roof (DL) =15 psf, Earthquake Design Data 1) Occupancy Category = I ASCE 7-05 Table 1- Occupancy Importance Factor Ie =1 ASCE 7-05 Table 11.5-1 Seismic Use Group = I 2) Mapped Spectral Response Accelerations ASCE 7-05 Fig 22-1, 22- 2 Latitude = 47.47 deg North Longitude =-122.26 deg West Location = Tukwila, Washington, 98188 Maximum Ground Motions, 5% Damnina, from USGS Mans Ss = 1.342 g, 0.2 sec response S1= .462 g,1.0 sec response 3) Site Classification ASCE 7-05 Table 20-3.1 Assumed D 4) Site Coefficients ASCE Table 7-05114.1. Fa = 1.00 Table 114.2' F,, = 1.54 5) Maximum Considered Earthquake Acceleration ASCE 7-0511.43 SMs = Fa * S, =1.34 SM1=Fv*Si= .711 6) Design Spectral Acceleration SDs = SMs * 2/3 = .894 SDI = SM! * 2/3 = .474 7) Seismic Design Category D 8) Basic Seismic Force Resisting System Force Resisting System Ordinary steel moment frames Response Modification Factor (R) =3.5 System Over Strength Factor `Wo" = 3.00 Deflection Amplification factor `Cd" = 3.00 9) Analysis Procedure The Equivalent Lateral Force Procedure ASCE 7-0511.4.4 ASCE 7-05 Tablell-6.1, Table 11-6.2 ASCE 7-05 Table 12-2.1 ASCE 7-0512.6 ASCE 7-0512.8 10) Building Period ASCE 7-0512.8.2 Structure Tvpe for Building Period Calculation All Other Structural Systems "Ct" value = .028 ASCE 7-05 Table 12.8-2 "x" value = .80 `ho' = 7.5' "Ta" = Ct*(hn^x) Approx. Fundamental Period ASCE 7-05 Eq. 12.8-7 .133 "Cu" =1.4 ASCE 7-05 Table 12.8-1 Per ASCE 7-0512.8.2 True Fundamental Period < (1.4)*(.224) = .313 11) "Cs" Response Coefficient ASCE 7-0512.8.1.1 SDs = .894 SDI = .474 SI = .462 g `R' = 3.5 "I" = 1.00 `TL" = 6 ASCE 7-05 Figure 22-15 (Eq.12.8.2) CS = SDs/(R/1) =155 Preliminary CS (Eq.12.8-3) C. = SDl/Ta(R/1) = .99 Need Not Exceed (Eq,12.8-5) C9 = .04 Shall no be less than (Eq.12.8-6) CS = .5 Sl/(R/1) = .066 Shall not be less than Therefore C, .26 12) Building Weight "W" = 26.6 K 13) Base Shear ASCE 7-0512.8-1 V=Cs*W (.26) * 26.6 = 6.92 K 14) Vertical Distribution of Seismic Forces See Spread Sheet REVIEWED FOR COMPLIANCE WITH REQUIREMENTS OF THE 2012 CO E Carport Replacement Title: Job # Cottage Creek Condominiums Dsgnr. Date: 4:33PM, 27 SEP 12 Description . Tukwila, Washington 98188 Scope: (� ) iN" . R.a0n13, Vw5.9.0, 1.oeo-= Earthquake Load Calculations Page 1 -(c)1983 4 ENtK-W- Cn-Saft+er wRaos creek condos.eawCelalalions Description Lateral forces Occupancy Category ASCE 7-02 Table 1-1, 2003 IBC Table 1604.5 "I" : Buildings and other structures that represent a low hazard to human life in the event of failu Occupancy Importance Factor = 1.00 ASCE 7-02 9.1.4 Seismic Use Group = I ASCE 7-02 Table 9.1.3 Ground Motion ASCE 7-02 9.4.1.1, 2003 IBC 1615.1 Latitude = 47.443 deg North Longitude = 122.270 deg West Location: SEATTLE, KING County, WA 98188 Max. Ground Motions, 5% Damping, from USGS 1996 maps: S S = 1.342 g, 0.2 sec response S, = 0.462 g,1.0 sec response Site Classification ASCE 7-02 Table 9.4.1.2, 2003 IBC Table 16.15.1.1 "D" : Shear Wave Velocity 600 to 1,200 ft/sec - D Site Coefficients Fa & Fv ASCE 7-02 9.4.1.2.4, 2003 IBC 1615.1.2 (using straight-line interpolation from table values) Fa = 1.00 Fv = 1.64 Maximum Considered Eartguake Acceleration ASCE 7-02 Equation 9.4.1.2.4-1 & 2, 2003 IBC Equations 16-38 & 16-39 S MS = Fa ' Ss = 1.342 SM1 = Fv' S1 = 0.711 Design Spectral Acceleration ASCE 7-02 9.4.1.2.5, 2-31BC 1615.1.3 S DS = S MS* 213 — 0.894 SDI =SMI*213 = 0.474 Seismic Design Category Basic Seismic Force Resisting System Moment Resisting Frame Systems Ordinary steel moment frames Response Modification Coefficient " R System Overstrength Factor " Wo Deflection Amplification Factor " Cd D ASCE 7-02 9.4.2.1, 2003 /BC 1616.3 (SDS is most severe) ASCE 7-02 Table 9.5.2.2, 2003 IBC Table1617.6.2 NOTE! See ASCE 7-02 for all applicable footnotes. 3.50 Building height Limits: 3.00 Category "A & B" Limit: No Limit 3.00 Category "C" Limit: No Limit Category"D" Limit: Not PermittedP-hi Category "E" Limit: Not PermittedP-hi Category "F" Limit: Not PermittedP-hi REVIEWED FOR COMPLIANCE WITH REQUIREMENTS OF THE 2012 CODE Carport Replacement Title : Job # Cottage Creek Condominiums Dsgnr. Date: 4:33PM, 27 SEP 12 Description Tukwila, Washington 98188 Scope: Q Revs 580016 User. KW-",r?83, Ver6.8.0,1-oec�z003 Earthquake Load Calculations Page 2 --(c)4W3-2003-ENERGAL-G-Engineering-Soft-- cortege creek condos.eav:Calculffikms Description Lateral forces Average Floor Area per Level = 702 ft2 User defined Shear Carrying % Ratio = 1.000 Reliability Factor " p " = 1.245 Equivalent Lateral Force Procedure ASCE 7-02 9.5.2.5, 2003 !BC 1617.4 The "Equivalent Lateral Force Procedure" is being used according to the provisions of ASCE7-02 9.5.5 Determine Building Period Use ASCE 9.5.5.3.2 -1 Structure Type for Building Period Calculation: STEEL 100% Moment Resisting Frame " Ct "value — 0.028 " hn " : Height from base to highest level = 7.00 " x "value = 0.80 " Ta " Approximate fundemental period using Eq. 9.5.5.3.2 -1 : Ta = Ct ` (hn ^ x) = 0.133 " Cu " factor from Table 9.5.5.3.1 = 1.40 Per ASCE 9.5.5.3.1 the true fundamental Building Period shall not exceed: = 0.186 sec Building Period " Ta " Calculated from Approximate Method selected = 0.133 sec " Cs " Response Coefficient ASCE 7-02 9.5.5.2.1 SDS: Short Period Design Spectral Response per 9.4.1.2 = 0.894 " R " : Response Modification Factor from 9.5.2.2 = 3.50 " I " : Occupancy Importance Factor from 9.1.4 = 1.00 From Eq. 9.5.5.2.1-1 : Preliminary Cs = 0.26 From Eq. 9.5.5.2.1-2 Cs need not exceed = 0.00 From Eq. 9.5.5.2.1-3 & 4 Cs shall not be less than = 0.04 9.5.5.2.1 : Seismic Response Coefficient 0.26 Seismic Base Shear ASCE 7-02 9.5.5.2 Cs = 0.2555 from 9.5.5.2.1 W ( see Sum Wi below) = 26.60 k Seismic Base Shear V = Cs " W = 6.80 k Vertical Distribution of Seismic Forces ASCE 7-02 9.5.5.4 " k " : hx exponent based on Ta = 1.00 Table of building Weights by Floor Level... Level # WI: Weight HI: Height Wi ' Hi"k Cvx Fx=Cvx' V Sum Story Shear Sum Story Moment 1 26.60 7.50 199.50 1.00 6.80 6.80 0.00 Sum Wi = 26.60 k Total Base Shear = 6.80 k Sum (Wi • MIA k) = 199.5 k-ft Base Moment = 51.0 k-ft Dlaphraam Forces: Seismic Desian Category " D ". " E " & " F " ASCE 7-02 9.5.2.6.4.4 Level # Wi Fi Sum Fi Sum Wi Fpx 1 26.60 6.80 6.80 26.60 6.80 REVIEWED FOR COMPLIANCE WITH REQUIREMENTS OF THE t2012 CODE Carport Replacement Title Cottage Creek Condominiums Dsgnr. Description Tukwila, Washington 98188 Scepe : Job # Date: 4:33PM, 27 SEP 12 0 Rev: 580016 User. KW-=7783, ver 5.8.0, 143ec2003 Earthquake Load Calculations Page 3 ic)1983-20M-ENERGAL$f�ofiware cdtega creek cados.W-W..Ca1VJWi0M Description Lateral forces Wpx .................... Weight at level of diaphragm and other structure elements attached to it. Fi ...................... Design Lateral Force applied at the level. Sum Fi .................. Sum of "Lat. Force" of current level plus all levels above MIN Req'd Force @ Level ... 0.20 * S DS* I * Wpx MAX Req'd Force @ Level .. 0.40 * S DS* I * Wpx Fpx : Design Force @ Level. Wpx * SUM(x->n) Fi / SUM(x->n) wi, x = Current level, n = Top Level Combination of Load Effects ASCE 7-02 9.5.2.7, 2003 IBC 1617.1.1 D Qe H & V Load Effect Load Description Dead Load Seismic Load 0.000 0.000 E = p * Qe + 0.20' SDS * D = 0.000 0.000 0.000 E = p . Qe + 0.20 * SDS * D = 0.000 0.000 0,000 t = p - ue + u.zu ' Sus ' u = 0.000 0.000 0.000 E = p * Qe + 0.20 * SDS * D = 0.000 0.000 0.000 E = p * Qe + 0.20 ' SDS * D = 0.000 0.000 0.000 E = p * Qe + 0.20 * SDS * D = 0.000 0.000 0.000 E = p * Qe + 0.20 • SDS * D = 0.000 0.000 0.000 E = p * Qe + 0.20 ` SDS ' D = 0.000 E STEPHEN TAPP JOB- co C44Zec. ARCHITECT/P.E. 2330 East Madison Street SEATTLE, WA 98112 (206) 320-0534 SHEET NO. 9 OF �j CALCULATED BY DATE_ 8/21/15 CHECKED BY DATE SCALE rLf- 41 �, �► L D PRODUCT207 REVIEWED FOR COMPLIANCE WITH REQUIREMENTS OF THE 2012 C D Carport Replacement Title: Job # Cottage Creek Condominiums Dsgnr: Date: 1:47PM, 29 SEP 12 Description: Tukwila, Washington 98188 Scope Re v: KW-0607783, ver 5.e.0, 1-Deo-2003 Page 1 fc)9883.2UO3f RGAL-�BinBarino-software Multi -Span Steel Beam ttage creek condos.ecw.Calcuiations Description RB-100 General Information Code Ref. AISC 9th ASD, 1997 UBC, 20031BC, 2003 NFPA 5000 Fy - Yield Stress 50.00 ksi Load Duration Factor 1.15 Spans Considered Continuous Over Supports Span Information Description spare I span 2 ww3 Span it 9.00 18.00 9.00 Steel Section HMX3x3/1e N959x3x3/1e /ie End Fibty Free -Pin Pin -Pin Pin -Free Unbraced Length ft 9.00 18.00 9.00 Loads Live Load Used This Span 7 Yes Yes Yes Dead Load k/ft 0.050 0.050 0.050 Live Load k/ft 0.250 0.250 0.250 Results Mmax @ Cntr k-ft 0.00 0.00 0.00 @ X = it 0.00 9.00 0.00 Max @ Left End k-ft 0.00 -12.15 -12.15 Max @ Right End k-ft -12.15 -12.15 0.00 fb : Actual psi 17,449.5 17,449.5 17,449.5 Fb : Allowable psi 34,500.0 34,500.0 34,500.0 Sending OK Sending OK Sending OK tv : Actual psi 862.1 862.1 862.1 Fv : Allowable psi 20,000.0 20,000.0 20,000.0 Reactions & Deflections Shear @ Left k 0.00 2.70 2.70 Shear @ Right k 2.70 2.70 0.00 Reactions... DL @ Left k 0.00 0.90 0.90 LL @ Left k 0.00 4.50 4.50 Total @ Left k 0.00 5.40 5.40 DL @ Right k 0.90 0.90 0.00 LL @ Right k 4.50 4.50 0.00 Total @ Right k 5.40 5.40 0.00 Max. Deflection in -0.910 0.130 -0.910 . @ X = it 0.00 9.00 9.00 Span/Deflection Ratio 237.4 1,661.4 237.4 Query Values Location ft 0.00 0.00 0,00 0.00 0.00 0.00 0.00 0.00 Shear k 0.00 2.70 2.70 0.00 0.00 0.00 0.00 0.00 Moment k-ft 0.00 -12.15 -12.15 0.00 0.00 0.00 0.00 0.00 Max. Deflection in -0.9098 0.0000 0.0000 0.0000 O.0000 0.0000 0.0000 0.0000 REVIEWED FOR COMPLIANCE WITH REQUIREMENTS OF THE 2012 CODE Carport Replacement Tide: Job # Cottage Creek Condominiums Dsgnr. Date: 2:42PM, 29 SEP 12 Description : tt Tukwila, Washington 98188 Scope: .f Rev: 580007 a User: Kw-0607783,vers.e.0, 1-DeU2003 Multi Steel Beam Page 1 _jc)1983.2003 E E-AX--8fnginearing-Sonware-- cottage creek condos.ecw:Caiwtaiions Description Steel Roofing General Infonnation Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00 Spans Considered Continuous Over Supports Span Information Description span 1 span 2 span 3 Span ft 4.00 12.00 4.00 Steel Section TSM=116 T52x2E3/16 TSM=116 End Fbity Free -Pin PirnPin Pin -Free Unbraced Length ft 4.00 12.00 4.00 Loads Live Load Used This Span 7 Yes Yes Yes Dead Load Wit 0.010 0.010 0.010 Live Load k/ft 0.025 0.025 0.025 Results Mmax @ Cntr k-ft 0.00 0.35 0.00 @ X = ft 0.00 6.00 4.00 Max @ Left End k-ft 0.00 -0.28 -0.28 Max @ Right End k-ft -0.28 -0.28 0.00 fb : Actual psi 5,029.9 6,287.4 5,029.9 Fb : Allowable psi 30,000.0 33,000.0 30,000.0 Bending OK Bending OK Bending OK fv : Actual psi 186.7 280.0 186.7 Fv : Allowable psi 20,000.0 20,000.0 20,000.0 Reactions & Deflections Shear @ Left k 0.00 0.21 0.14 Shear @ Right k 0.14 0.21 0.00 Reactions... DL @ Left k 0.00 0.10 0.10 LL @ Left k 0.00 0.25 0.25 Total @ Left k 0.00 0.35 0.35 DL @ Right k 0.10 0.10 0.00 L.L @ Right k 0.25 0.25 0.00 Total @ Right k 0.35 0.35 0.00 Max. Deflection in 0.200 -0.393 0.200 @ X = ft 0.00 6.00 4.00 Span/Deflection Ratio 480.4 366.1 480.4 Query Values Location ft 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Shear k 0.00 0.21 0.14 0.00 0.00 0.00 0.00 0.00 Moment k-ft 0.00 -0.28 -0.28 0.00 0.00 0.00. 0.00 0.00 Max. Deflection in 0.1998 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Carport Replacement Cottage Creek Condominiums Tukwila, Washington 98188 Description C-100 REVIEWED FOR COMPLIANCE WITH REQUIREMENTS OF THE 2012 CODE Title : Dsgnr. Description: Scope : Steel Column Job # Date: 2:23PM, 29 SEP 12 12 General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Steel Section HSS3X3X114 Fy 45.00 ksi X-X Sidesway : Restrained Duration Factor 1.330 Y-Y Sidesway : Restrained Column Height 7.600 ft Elastic Modulus 29,000.00 ksi End Fixity Pin -Pin X-X Unbraced 7.500 ft Kxx 1.000 Live & Short Term Loads Combined Y-Y Unbraced 7.500 ft Kyy 1.000 Loads Axial Load... Dead Load 1.80 k Ecc. for X-X Axis Moments 0.000 in Live Load 4.50 k Ecc. for Y-Y Axis Moments 0.000 in Short Tern Load k Point lateral Loads... DL LL ST Height Along Y-Y (strong axis moments) 1.700 k 7.500 ft Along X-X (y moments) k ft vnui�air s Column Design OK Section: HSS3X3X1 /4, Height = 7.60ft, Axial Loads: DL = 1.80, LL = 4.50, ST = O.00k, Ecc. = 0.000in Unbraced Lengths: X-X = 7.50ft, Y-Y = 7.50ft Combined Stress Ratios Dead Live_ DL + Lt. DL + ST + (LL if Chosen) AISC Formula H1 -1 AISC Formula H1 - 2 AISC Formula H7 - 3 O.D417 0.1043 0.1460 0.1376 XX Axis : Fa calc'd Per Eq. E2-1, Mr < Cc YY Axis : Fa calc'd Per Eq. E2.1. K*Ur < Cc Stresses Allowable & Actual Stresses Dead iv DL + LL DL + Short Fa: Allowable 17.69 ksi 17.69 ksi 17.69 ksi 23.53 ksi fa : Actual 0.74 ksi 1.84 ksi 2.58 ksi 2.58 ksi Fb:xx : Allow [F3.1 ] 27.00 ksi 27.00 ksi 27.00 ksi 35.91 ksi fb : xx Actual 0.00 ksi 0.00 ksi 0.00 ksi 1.00 ksi Fb:yy : Allow [F3.1] 27.DO ksi 27.00 ksi 27.00 ksi 35.91 ksi fb : yy Actual 0.00 ksi 0.00 ksi 0.00 ksi 0.00 ksi Analysis Values F'ex : DL+LL 22,818 psi Cm:x DL+LL 0.60 Cb:x DL+LL 1.00 Fey: DL+LL 22,818 psi Cm:y DL+LL 0.60 Cb:y DL+LL 1.00 Fex: DL+LL+ST 30,348 psi Cm:x DL+LL+ST 1.00 Cb:x DL+LL+ST 1.00 Fey: DL+LL+ST 30,348 psi Cm:y DL+LL+ST 0.60 Cb:y DL+LL+ST 1.00 Max X-X Axis Deflection -0.012 in at 4.408 ft Max Y-Y Axis Deflection 0.000 in at 0.000 It REVIEWED FOR COMPLIANCE WITH REQUIREMENTS OF THE 2012 CODE Carport Replacement Title-: Job # Cottage Creek Condominiums Dsgnr: Date: 2:23PM, 29 SEP 12 Description Tukwila, Washington 98188 Scope : C3) Rer. 580009 User. KW-%07783, Ver5.8.0,1-Deo2w3 Steel Column Page 2 tc)1983=2003£NERM--GEngineenngsaftwere- cone" creek condmvar.Celculations Description C-100 Section Properties HSS3X3X1/4 Depth 3.000 in Weight 8.29 Nit Values for LRFD Design.... Web Thick 0.233 in boc 3.020 in4 J 5.080 in4 Width 3.000 in lyy 3.020 in4 Cw 3.52 in6 Flange Thick 0.233 in Sxa 2.010 in3 Zx 2.480 in3 Area 2.44 in2 Syy 2.010 in3 Zy 2.480 in3 Rt 0.000 in Roc 1.110 in 0.000 Ryy 1.110 in Section Type = HSS-Square Axial DL = 1.80k Axial LL = 4.50k Axial ST = 0,00k 7.60 ft O3 X-X Axis Point Load: DL=0.0, LL=0.0, ST=1.7 k @ 7.50ft e Carport Replacement Title : Job # Cottage Creek Condominiums Dsgnr. Date: 2:19PM, 29 SEP 12 Description: Tukwila, Washington 98188 Scope : 15 Rev: 580002 User. KW-0807783, Ver5.8.0, 1-Dec-2003 Pole Embedment -in Soil Page 1 _(c)t983=30M-ENERC-ALe—E-VneerirpSoRware- cottage creek condos.eav:CalculaUom Description rectalgular pole with Point & Unfform Loads General Information Code Ref: 1997 UBC 1806.8.2.1, 2003 IBC 1805.7.2, 2003 NFPA 5000 36.4.3 Allow Passive 300.00 pcf Applied Loads... Max Passive 1,500.00 Psf Point Load 1,700.00 Ibs Load duration factor 1.330 distance from base 7.500 ft Pole is Circular Diameter 18.000 in Distributed Load 0.00 #1ft Restrained @ Surface distance to top 0.000 It distance to bottom 0.000 ft Summary Moments @ Surface... Point load 12,750.00 ft-# Total Moment 12,750.00 ft-# Distributed load 0.00 Total lateral 1,700.00 ►bs With Surface Restrain... Req'd Depth 4.500 ft Pressure @ Base... Actual 1,791.64 psf Allowable 1,791.64 psf Surface Restraint Force 5,880.28 Ibs REVIEWED FOR COMPLIANCE WITH REQUIREMENTS OF THE 2012 CODE STEPHEN TAPP ARCHITECT/P.E. 2330 East Madison Street SEATTLE, WA 98112 (206) 320-0534 16 SHEET NO. OF CALCULATED BY DATE- 8/21 /1 5 _ CHECKED BY DATE SCALE f,9L J7L' 14"y�� #hh yv:�'t- I C/119 H ft� 2��1 1:701 L. y� D PRODWr207 Carport Replacement Title: Job # Cottage Creek Condominiums Dsgnr: Date: 2:56PM, 29 SEP 12 Description Tukwila, Washington 98188 Scope: 17 Rev. 58= uses uwo5onea,vers.a.o, oe�-zoo3 Pole Embedment in Soi{ Page 1 �c)'W3-2883fNERC1Lf:En81 �9-SofMare--- cottage creels corKlos.ecw:Calwli.. Description rectaigular pole with point & uniform loads I General Information Code Ref: 1997 UBC 1806.8.2.1, 2003 IBC 1805.7.2, 2003 NFPA 5000 36.4.3 it Max Passive 1,500.00 psf Point Load 1,650.00 Ibs Load duration factor 1.330 distance from base 7.500 it Pole is Circular Diameter 20.000 in Distributed Load 0.00 #Jft Restrained @ Surface distance to top 0.000 ft distance to bottom 0.000 ft Summary Moments @ Surface... Point load 12,375.00 ft-# Total Moment 12,375.00 ft-# Distributed load 0.00 Total Lateral 1,650.00 Ibs With Surface Restraint.. Req'd Depth 4.126 ft Pressure @ Base... Actual 1,898.05 psf Allowable 1,898.05 psf Surface Restraint Force 5,974.85 Ibs REVIEWED FOR COMPLIANCE WITH REQUIREMENTS OF THE 2012 CODE STEPHEN TAPP J013 ARCHITECT/P.E. 18 2330 East Madison Street SHEET No. oP SEATTLE, WA 98112 CALCULATED BY (206) 320-0534 °ArE_" CHECKED BY DATE - SCALE Nj 1-21h.44-7 M = 4-� y� = C�r)Ciz) f�l V- i,I N f ( 2z &JA) Ael hXf4+4Et. 1 1 Z/32 1 " 0 pf 1j Z- • ! 01 i�3 T4�-T of lz.. � �. F LN Z+/N4- 2 4- 1V1= ,z1 \\ FilH 14) o, A � D PRODUCT 0 a. Profile Type (dimensions in inches) WeighU�) Section Properties per ft (m) of width GaIv Painted I +S -S psf psf in. 4 in.3 in. 3 Gage NIM2 NIM2 MM4 MM3 MM 22 1.9 1.8 0.175 0.187 0.198 I Y2' 21/2 • 2.3 862 ........... 2.2 2.38,978 0.216 10.054 0.235 10.645 0.248 20 110.1 105.3 294,967 12,634 13,333 13%, 2.9 2.8 0.302 0.322 0.335 2 36' 18 138.9 134.1 412,408 17,312 18.011 3.5 3.4 0.377 0.411 0.417 16 167.6 162.6 514,827 22.097 22.419 2.2 2.1 0.655 0.394 0.454 22 CY z 5%* et C? 3* U z 24'_� 105.3 100.5 894,460 21,183 24.408. 2.6 2.5 0.837 0.508 0.562 20 124.5 119.7 1,142,997 27,312 30.215 3.5 3.4 1.223 0,731 0,776 167.6 162.8 1,670,114 39,301 41.720 16 4.2 4.1 1.647 0.950 1.005 201.1 196.3 2,249,123 51,075 54.032 26 1.1 0.073 0.099 0.103 iyw" V, 3A* 4Y2' I. ..52,_7 - .991,6.88 ------ 5,323 5.538 24 1.4 0.098 0.138 0.140 UA 0 67.0 133,826 7,419 7.527 W L) 36' 22 1.7 0.123 0.175 0.174 Ui > 81.4 167,967 9,409 9.355 20 2.1 0.143 0.207 0.206 100.5 195,279 11,129 11,075 1. Section properties have been computed in accordance with the "Specification for the Design of Cold -Formed Steel Structural Members" published by AISL The section properties are based on the following steel strengths: Profile i Minimum Yield Strength (Fy) PLBTm-36/HS8@-36 PLNTm-24/N-24 Deep VERCORTm 38 ksi (262,000 kPa) 33 ksi (227,527 kPa) 80 ksi (551,581 kPa) Bending Strength (Fb) 22.8 ksi (157,200 kPa) 20.0 ksi (137, 895 kPa) 36.0 ksi (248,211 kPa) 2. Section properties and values shown apply to all available widths. 3. Material thickness is subject to AISI tolerances. See ICBO ES Report ER-2078P for decimal thickness of material. 4. Weights shown are approximations for design purposes. 5. All dimensions are nominal and are subject to manufacturing tolerances. Metric Conversions in. RIM in. Ulm in. MM in. MM in. MM 1 25 13/, 44 2% 67 4 Y2 114 8 203 15/16 33 1 48 3 76 5% 137 24 610 ...... .... 1 Y2 38 2 Y2 64 3Y2 89 fol 152 36 914 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director January 4, 2016 STEPHEN TAPP 2330 MADISON ST SEATTLE, WA 98112 RE: Application No. D15-0216 COTTAGE CREEK CONDOS - CARPORT 15344 62ND AVE S Dear STEPHEN TAPP: Permit application D15-0216 for the work proposed at COTTAGE CREEK CONDOS - CARPORT (15344 62ND AVE S) has not been issued by the City of Tukwila Permit Center. Per the International Building, Residential, and Mechanical Codes as well as the Uniform Plumbing Code and/or the National Electric Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire D15-0216. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is completed for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that your permit is not issued, we do not receive your written request for extension, or your request is denied your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D15-0216 6300 Southcenter Boulevard Suite #100 • Tukwila. Washington 98188 • Phone 206-431-3670 • Fax 206-4.31-3665 City of Tukwila Department of Community Development September 03, 2015 STEPHEN TAPP 2330 E MADISON ST SEATTLE, WA 98112 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D15-0216 COTTAGE CREEK CONDOS - CARPORT — 15344 62ND AVE S Dear STEPHEN TAPP, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size l 1x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) All Structural Drawings and structural calculations sheets to be stamped (original signed wet stamp, not copied) by Washington State licensed architect, structural engineer or civil engineer. (BUILDING REVIEW NOTES) 1. Structural calculations make reference to compliance with outdated codes 2003 IBC and 1997 UBC. Provide revised calculations that show design criteria complies with current 2012 codes. 2. Provide quality control special inspection recommendations for the steel construction, reinforcing steel and concrete placement as it applies. Inspection table or note references shall be on the plan sheet. (IBC Section 17) Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your, convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-433-7165. Sincerely, wv�?Rachelle Ripley Permit Technician File No. D15-0216 6300.Southrenter Boulevard ,Suite #100 • Tukwila Washington 9R1RR • Ph.nne 206-437-3670 o Fnx 206-437-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0216 DATE: 09/17/15 PROJECT NAME: COTTAGE CREEK CONDOS CARPORT SITE ADDRESS: 15344 621D AVE S Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: 1 AS nc. Building Division IN Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 09/17/15 Not Applicable ❑ Structural Review Required ❑ (no approval review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/15/15 Approved ❑ Approved with Conditions NIT Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0216 DATE: 08/25/15 PROJECT NAME: COTTAGE CREEK CONDOS - CARPORT SITE ADDRESS: 15344 62 AVE S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: W vc, RK 01 gitdinhgD)ivisi�oneb Fire Preventiorl Planning Division Public Works Structural Permit Coordinator PRELIMINARY REVIEW: DATE: 08/27/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DUE DATE: Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: All� Departments issued corrections: BligN Fire ❑ Ping ❑ PW ❑ Staff Initials: 09/24/15 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.Tukwi]aWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: I /► a 4,01 Plan Check/Permit Number: D15-0216 ❑ Response to Incomplete Letter # ® Response to Correction Letter # I ❑ Revision # after Permit is Issued �r OF� ILA ❑ Revision requested by a City Building Inspector or Plans Examiner 10 2015 ❑ Deferred Submittal # PEPAPT CFNTFR Project Name: COTTAGE CREEK CONDOS CARPORT Project Address: 15344 621D AVE S Contact Person: f5m� Summary of Revision: 3 Phone Number: 4,99 - 5j 115 1 ter. •� i�� � :. Sheet Number(s): I "Cloud" or highlight Received at the City of Tukwila Permit Center by: ❑ Entered in TRAKiT on W:\Permit Center\Templates\forms\Revision Submittal Porm.doc Revised: August 2015 D & J CUSTOM METAL FAB INC Page 1 of 2 Home Inicio en Espanol Contact Safety Washington State Department of Labor & Industries D & J CUSTOM METAL FAB INC Search L&I A-7 Index Help :sty Secure 1: `�I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 11615 12TH AVE S Principals SEATTLE, WA98168 p 206-242-3238 WILCOX, DAVID J KING County WILCOX. JUDY L Doing business as D & J CUSTOM METAL FAB INC WA UBI No. Business type 601 944 022 Corporation Governing persons DAVI D JOHN WILCOX JUDY LYN WILCOX; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .................................................._........_........... Meets current requirements. License specialties GENERAL License no. DJCUSMF011 MH Effective — expiration 07/0811999— 05/01 /2016 Bond ................. Lexon Ins Co $12,000.00 Bond account no. 9805210 Received by L&I Effective date 03/31/2011 05/01/2011 Expiration date Until Canceled Bond history Insurance Charter Oak Fire Ins Co $1,000,000.00 Policy no. 6803021M726 Received by L&I Effective date 04/29/2015 04/29/2011 Expiration date 04/29/2016 Insurance history Savings No savings accounts during the previous 6 year period. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601944022&LIC=DJCUSMFOIIMH&SAW= 1/7/2016 A.SCE 75 General Conditions %s'.t;�c. .:.`.''�.':Oxap.' 2 i. ..5z rS.e ..ask'$'...* >ii.. u.,%.a ... Damaged Carport Code 2012 IBC AISCIASII Ninth Edition AC:I: 3.18-05 iD.S 20 SEAW Rapid Solutions Methodoloff for Wind Design WLnd..Desigm, Wind Speed = 85 MPH Wind Exposure - ,B' Soil Loads (assumed) No sails report availably Active Equivalent fluid pressure. =35 psf (U:nrestralned Wall) Passive pressure = 300 psf Assaulted Soil density @ 115 pct Assumed :soli. Bearing Pressure: = 2M psf ug dinn Loads Snow Load = 25 psi' 3of (DL) —1 psf, (l FL) =25 psf Exterior Wall tDl,l =1.5 p8f Concrete/Foundation Notes > Foundation design is in accordance with chapter 19 of the 2012 IBC. All work shall be performed in accordance with all current building and safety codes. > Concrete strengths shall be verified by standard 28-day cylinder tests, unless approved otherwise. > Anchor bolts to be 5/811diameter with 10" embedment @ 48" o.c. (see shear wall schedule for anchor bolt size and spacing at other than P1-6" shearwalls). All anchor bolts to be ASTM A-307. > Assumed soil bearing pressure = 2000psf. > Backfill behind unbraced retaining walls prior to attaching floor diaphragm. > Ezterior footings to be entrenched a minimum of 18" below existing grade and bear on firm undisturbed soil. > All reinforcing bars to be Grade 40 deformed bars. The tie wire is to be 16 Ga. double annealed wire. Lap all reinforcing 36 diameters. At corners of walls extend horizontal bars 2" from outside face of wall and lap with elbow bars of 30 diameters at the same size and spacing. Provide 245 bars around all wall openings. Provide footing dowels to match vertical reinforcing. Concrete cover 3" concrete poured against earth 2" formed concrete with earth backfill 1 1/2" outside face of walls exposed to weather, slabs on a moisture barrier 1" walls, outside face > Provide 4"diameter perforated PVC drain in granular fill at the base of all new exterior footings (existing and new). Concrete mix Mix design shall be in conformance with ACI-318-99. Submit mix designs jo engineer of record 2 weeks prior to placement indicating where each concrete mix is used and the maximum aggregate size. type fle max.water/cem.ratio min. non -air ent. air ent. sks/cu.yd. ftgs 3000 .65 .42 6 found.walls slab on grade 3000 .65 .50 5'/2 > Water reducing mixtures may be incorporated into the mix designs in accordance with ASTM C 494 and manufacturer's recommendations. >VVater/Cement ratio shall be measured by weight and shall be based on the total cementious material. Water/Cement ration shall be determined by the supplier based on the strength requirements and shall no exceed the maximum water/cement ratio shown above. > Contractor will call for inspection prior to placing any footing and foundation wall concrete. > Provide rigid insulation around the perimeter of all slabs within heated spaces. > Permanent cut and fill slopes should not exceed 2:1(MV). > All reinforcing shall be detailed in accordance with ACI detailers manual. > All excavations shall be adequately barricaded and marked. All work area and surfaces shall be cleaned upon completion of the project. All debris and waste materials shall be removed off the site to an approved disposal area by the contractor. -Use air -entrained (3%-6%) in all flat work exposed to weather. - Master flow 928 or equal. > Provide minimum of 1/2" air space between non -pressure, treated wood and concrete, or provide waterproofing membrane between concrete and non -pressure treated wood. > Top of concrete to be field verified by contractor. > Contractor to field verify existing grade cut and soil conditions . with before proceeding with concrete retaining wall forming and reinforcing steel placement. > Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the work. >In the case of discrepancies between the drawings and the anticipated field conditions the contractor shall notify the architect before proceeding with construction. >DO NOT SCALE the architects or engineer's drawings — noted dimensions take precedence over scaled dimensions. Structural tee eldin Steel design, fabrication and erection shall conform to the requirements of chapter 22 of the 2012IBC. Substitution of member sizes or steel grade will not be allowed without prior approval of the engineer of :record. > The contractor shall be responsible for all erection aids and joint preparations that include but are not limited to erection angles, lift holes and other aids, welding procedures required root openings, root face dimensions, groove angles, backing bars, scopes, surface roughness values and unequal parts. > Expaansion bolts shall be ICBO approved and installed per the manufacturer's recommendations. >Unless otherwise specked on drawings or details, size and embedment depths shall be approved by the engineer of record. Materials structural steel .ATM A 992Grade50 connection material,-ASTM'A 36 G embedded items, channels, angles, base plates structural tubes -ASTM A 500, grade B structural bolts -.ASTM A 325-N wood connection bolts -ASTM A 307 anchor bolts -ASTM A 307 threaded rods -.ASTM A 36 welding electrodes 70ksi, LowHydrogen >Beam camber noted on drawings is. the upward. camber required in the beam as delivered to the job site. The Contractor shall consider camber loss due to shipping and handling. > Structural steel and connections exposed to weather ,shall be hot dipped galvanized after fabrication in compliance with ASTM A 123. All field welds on galvanized material, shall be coated with brush applied zinc -rich paint complying with ASTM A 780 (Galvacon or equivalent). Note: All welding to be performed by a WABO certified welder and special inspection to be performed by the structural engineer of record. SPECIAL INSPECTIONS SUBMITTALS SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD ..PRIOR TO ANY FABRICATION OR CONSTRUCTION FOR ALL STRUCTURAL ITEMS. INSPECTIONS NX SPECIAL INSPECTION FOR ALL AREAS OF THE STRUCTURE AND SUPPORTING FOUNDATION PER CHAPTER 17, 2012 IBC SHALL BE PERFORMED BY AN APPROVED TESTING AGENCY, ITEMS TO BE TESTED FOR WELDED COMPONENTS, WELDS MEET VISUAL INSPECTION CRITERIA. FOR WELDED COMPONENTS, VERIFY WELDING PROCEDURES (WPS) AND CONSUMABLE CERTIFICATES. FOR WELDED COMPONENTS, VERIFY WELDERS ARE APPROPRIATELY QUALIFIED. FOR BOLTED CONNECTIONS VERIFY FASTENERS HAVE BEEN MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS. FOR BOLTED CONNECTIONS, VERIFY GRADE, TYPE, AND BOLT LENGTH IF THE THREADS ARE EXCLUDED FROM THE SHEAR PLANE. FOR STRUCTURAL STEEL, ALL FABRICATED STEEL SHALL BE INSPECTED TO VERIFY COMPLIANCE WITH THE DETAILS SHOWN IN THE CONSTRUCTION DOCUMENTS. FOR STEEL ROOF, CONFIRM THAT IDENTIFICATION MARKINGS ARE PROVIDED TO CONFORM TO ASTM STANDARDS SPECIFIED ON CONSTRUCTION DOCUMENTS. FOR CONCRETE, VERIFY PRIOR TO PLACING CONCRETE THAT REINFORCING IS OF SPECIFIED TYPE, GRADE, AND SIZE; THAT IT IS LOCATED AND SPACED PROPERLY; THAT HOOKS, BENDS, TIES, STIRRUPS AND SUPPLEMENTAL REINFROCEMENT ARE PLACED CORRECTLY vEr`Al"iriTC !-�RMI! REO UIRED FOR: MMechaniaw CWlectrical 1L�Plumbing 45as Piping y of Tukwila Na changes shall of beivimo made to the scope work without prior approval of Tt"'wila Building Division. NIO ± is Fev!s'0ns will require a new plan submittal and may include additional plan review fees. FILE COPY Permito, Plan review approval is .subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt Of approved Field Copy and conditions is acknowledged: Date: City of Tukwila BUILDING DIVISION Sheet Index S-1 STRUCTURAL NOTES, SITE PLAN, CODE REFERENCES S-2 FRAMING PLANS AND STRUCTURAL DETAILS Project Description REPLACE DAMAGED ROOF AND STRUCTURE ON EXISTING CARPORT Occupancy/Use Group U, carport `wilding Area 20' x 36' = 720 sq.ft. REV'k : ®F4 CODE C A SEP 2 4 2015 ity �t1tLQiNG DI ISI revisions 9/9/15