Loading...
HomeMy WebLinkAboutPermit D15-0230 - NC MACHINERY - BUILDING 3 - SHOP AND OFFICENC MACHINERY BLDG 3 17025 W VALLEY Fl\VY D15-0230 City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Q, Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 2523049046 Permit Number: D15-0230 Address: 17025 W VALLEY HWY 3 Issue Date: 10/14/2015 Permit Expires On: 4/11/2016 Project Name: NC MACHINERY - BLDG 3 Owner: Name: HARNISH GROUP INC Address: 17035 W VALLEY HWY , TUKWILA, WA, 98188 Contact Person: Name: TANYA JOHNSON Phone: (253) 922-4168 Address: 601 ST HELENS AVE, TACOMA, WA, 98402 Contractor: Name: HHJ INC Phone: (253) 380-3801 Address: PO BOX 27451, FEDERAL WAY, WA, 98093 License No: HHJINI*890D5 Expiration Date: 3/25/2017 Lender: Name: PROPEL INSURANCE Address: 1201 PACIFIC AVE #100 , TACOMA, WA, 98402 DESCRIPTION OF WORK: EXISTING INSULATED METAL PANEL BUILDING CONSTRUCTION. EXPAND EXISTING WEST END OFFICE AREA INTO SHOP AREA ON EAST END OF BLDG. ADD INSULATED FURRED WALLS TO EXTERIOR WALLS, ADD OFFICE ROOMS AND OPEN OFFICE AREA. Project Valuation: $100,000.00 Fees Collected: $2,577.02 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: VB Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: ChanneIization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Volumes: Cut: 0 Fill: 0 Number: 0 Water Meter: No Permit Center Authorized Signature: Date:IA_15� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting state or local development Signature: Print Name: permit does not presume to give authority to violate or cancel the provisions of any other �gulating construction or the performance of work. I am authorized to sign and obtain this and agree to the conditions attached to this permit. Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 18: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 3: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 4: Maintain fire extinguisher coverage throughout. 5: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 6: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 7: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 8: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 9: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 10: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.6) 11: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 12: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1011.6.3) 13: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 15: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 16: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72-17.5.3.1) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 20: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 21: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 24: 'BUILDING PERMIT CONDITIONS' 25: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 26: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 27: 'BUILDING PERMIT CONDITIONS' 28: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 29: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 30: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 31: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 32: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 33: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 34: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 35: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 36: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 37: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 38: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 39: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH & GYPSUM 0406 SUSPENDED CEILING 0601 WALL INSULATION t CITY OF TM -A Community Development Department • Public Works Department • Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwi]aWA.gov SITE LOCATION Building Pet-mait No. _ Project No. Date Application Accepted: Date Application Expires: tj 11 (For o tce use onl CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" King Co Assessor's Tax No.: 2,572 30 + —9O Site Address: (� O � U«�w I Suite Number: Floor: Tenant Name: 0(, MA-ChUU6wl (DWIW 0FA7uSWJ) ('65P- PROPERTY OWNER Name: P (�J G povs P Jac Address: 0635 Wk Vp.ta, ,O1 OY ��rE'T �IState: �i� Zipq (fig CONTACT PERSON - person receiving all project communication Name: AID uS`� Address: 6b V- ►i t G {� s p,06" City: bw State: t �.�J Zip:( ,0 Phone: m 9ZZ il Fax:.? Email: n CAL-3m GENERAL CONTRACTOR INFORMATION Company Name: H-) JAS C Address: 661 5 eU" ,5 E City: (e" State: w Zip: J Phone: -z 22- 16 a Fax: Contr Reg No.: N I t `t W Exp Date: 7 Tukwila Business License No.: i New Tenant: ❑ .....Yes 00..No ARCHITECT OF RECORD Company Name: Architect Name: Address: 6® 49LO-) S 40 �! City: ,� State: w Zip984PO2 Phon25 3 _9Z2_4/6 v Fax?S3e 9,22'*73-91 Email: G Q . ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: rooeL,- , W rj00-(/k1-) Address: ) Zt i PA , (ICMft # I �3t� City: � �1 State: k./j Zip:Q H:\Applications\Forms-Applications On Line\2011 Applications\Fermit Application Revised - 8-9-1I.docx Revised: August 2011 Page 1 of 4 hh BUILDING PERMIT INFORMATIC 206-431-3670 I Valuation of Project (contractor's bid price): $ f o-0, -00 0 Existing Building,,Valuation: � 00 C3 Describe the scope of work (please provide detailed information): �drl t GPI v � J e)((5,n PG 1 N S v vn t'' t, PAIL �3� LON 6 � % 1 C; 14PA1,49 6)(ISTVJ6 W6 a_f' eNo 01�6 c.6�"� 1t"5-TO SOCe /ttW'Q' 6xrnWM0TL, w+,k,5,14W opfc,(cE- -J :k cqa u of-fec-,F-AIW4 Will there be new rack storage? ❑..... Yes 9.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC la'Floor <f 0'? , s- V-13 51 2nd Floor L (0 3r Floor Floors 1 thru M eL lv Basement Accessory Structure* Attached Garage ✓ Detached Garage v Attached Carport J Detached Carport Covered Deck r Uncovered Deck / PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑....... Yes ❑....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ ....... Sprinklers ❑ ....... Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ....... Yes ❑ .......No If ` yes ', attach list of materials and storage locations on a separate 8-112 " x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ ....... On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 ApplicationsTermit Application Revised - 8-9.1l.docx Revised: August 2011 Page 2 of 4 bh PUBLIC WORKS PERMIT INFC [ATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ... Water District # 125 ❑ .. Highline El.. Renton ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ... Valley View ❑ .. Renton ❑ .. Seattle ❑ ...Sewer Use Certificate ❑ ... Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which am ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ... Hold Harmless — (SAO) ❑... Hold Harmless — (ROW) Proposed Activities (mark boxes that applv): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ .. Right-of-way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection _ Irrigation Domestic Water ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size.. " ❑ ... Water Only Meter Size............ " ❑ ...Sewer Main Extension .............Public ❑ ❑ ...Water Main Extension.............Public ❑ FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer Monthly Service Billing to: Mailing Water Meter Refund/Billing: Mailing WO# WO# WO# Private ❑ Private ❑ ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑... Deduct Water Meter Size '' Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: City Day Telephone: State Zip City State Zip H:\Applications\Forms-Applications On Line\201 1 ApplicationsTermit Application Revised - 8-9-1 t.docx Revised: August 2011 Page 3 of 4 bh APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNFR QR AUTHORIZED AGENT: Signature: Date: 1< 3 /2,o Print Name: v p �i� c.7b n Day Telephone: 06—� d 9 ZL --9'f 6 5 Mailing Address: G ST O R&vS 4 6- 17FCOMA- five - U —V0 2 City state Zip H:\Applications\Forms-Applications On Line12011 Applications\Fermit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,593.39 D15-0230 Address: 17025 W VALLEY HWY 3 Apn: 2523049046 $1,593.39 DEVELOPMENT $1,517.75 PERMIT FEE R000.322.100.00.00 0.00 $1,513.25 WASHINGTON STATE SURCHARGE 13640.237.114 0.00 $4.50 TECHNOLOGY FEE $75.64 TECHNOLOGY FEE TOTAL'AR6425 R000.322.900.04.00 0.00 $75.64 $1,593.39 Date Paid: Wednesday, October 14, 2015 Paid By: HARNISH GROUP INC Pay Method: CHECK 586654 Printed: Wednesday, October 14, 2015 12:24 PM 1 of 1 RWY57EM5 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $983.63 D15-0230 Address: 17025 W VALLEY HWY 3 Apn: 2523049046 $983.63 DEVELOPMENT $983.61 PLAN CHECK FEE R000.345.830.00.00 0.00 $983.61 TECHNOLOGY FEE $0.02 TECHNOLOGY FEE TOTAL1 '61: R000.322.900.04.00 0.00 $0.02 $983.63 Date Paid: Thursday, September 03, 2015 Paid By: HARNISH GROUP INC Pay Method: CHECK 584685 Printed: Thursday, September 03, 2015 3:11 PM 1 of 1 RWSYS7EM5 INSPECTION RECORD Di5--02-3�) INSPKTION NO. i Retain a copy with permit I PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206)431 _367�t Permit Inspection Request Line (206) 438-9350 Project- �Vc Type of I ectiv: Mf I Address: 17,eV�� VV Vf&'v � — te a e -,(/ Special Instructions: Dat0f Wanted: qZ-9 p.m. Requestep, Pho e N 2—Approved per applicable codes. El Corrections required prior to approval. I paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection, INSPECTION RECORD Retain a copy with permitl D 15':-0 �73V 19ZWION NO. , PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project* VC Type oLlpspection: 4;oeev-4w,<�V Address: ate Ca led: ;a tt Special Instructions: W nte —e a' a. rn,,, Requester: If P one No: M Approved per applicable codes. r4,to5<rections required prior to approva COMMENTS: PAM, w X �V,6;FOIWA, RON— A F-� REINSPECTION FEE REQUIRED. Prior to next inspection./ee must be paid at 6300 Southcenter Blvd., Suite 100. Catt to schedule rei nspection. INS ECTION RECORD Retain a copy with 'permitID1,5-0,z�6 I I I ECIION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 EProject�/ & ld Type of Insp �9*�De ress Date Called: S"pecial Instructions: Date Wanted* Requester: f Phone No: UaA--pproved per applicable codes. E I Corrections required prior to approval. paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permitP15�301 I"PECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P �w Type of In.Wction: d�:gm� AdIress: W V "20AS � - Date, , M: .00 Special Instructions: Dati-Wanted: p.m. Requester- -1/ PFo-neNo- 094-p;'roved per applicable codes. 0 Corrections required prior to approval. I I paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. W11 :0 INSPECTION RECORD. Retain a copy with permit INSPECTION NO. P E R M IT CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro ect: /1,11 A( A-1 Type of Inspection - Address: 0!5>A�57 k/ V,441cv Mov Date Called: 3 — Special Instructions: Date Wanted: a. P.M. Requester: Phone No: MA-5--p-m—I'd per applicable codes. E, I Corrections required prior to approval. p - aid at - 6300 Southcenter Blvd., Suite 100. CalL to s-chedule reinspection INSPECTION RECORD Retain a copy with permit J-D 376 INSPECTION NO. PERMIT NO. CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj ek/c/—' Type of Inspe I n: Address: /-70,)�,45- U) VA�lev /4 Called: 4-� ;/?- 2 Special Instructions: Date Wanted: a.ro, Requester: Ph No: A "'-7 E�fApproved per applicable codes. El I Corrections required prior to approva;. spector: F] REINSPECTION FEE REQUIRED. Prior to next inspection, f fle must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECOI RD. Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projec Type of InspWn: LCAjI4 Address: j:z0"'-Az;- k'-, Dat lied: / Y Special Instructions: Date Wanted: M Reque t Phone No: Corrections required prior to approval, Dgp-proved per applicable codes. E MENTS: I I - paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director September 25, 2015 TANYAJOHNSON 601 ST HELENS AVE TACOMA, WA 98402 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D15-0230 NC MACHINERY - BLDG 3 - 17025 WEST VALLEY HWY Dear TANYA JOHNSON, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size I Ix17 to maximum size of 2406; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) All Structural Drawings and structural calculations sheets to be stamped (original signed wet stamp, not copied) by Washington State licensed architect, structural engineer or civil engineer. (BUILDING REVIEW NOTES) 1. Provide a life safety plan that identifies means of egress. Dimension egress paths. Identify the specific common paths of egress that shall be provided with emergency illumination. Emergency illumination shall have at least an average 1 foot-candle and a minimum at any point of 0.1 foot candle measured along the path of egress at the floor level. Emergency lighting shall also be required for exit discharge doorways. Egress paths shall be continuous to each exit. Include the second floor mezzanine in the egress plan. Designed egress paths shall be those inspected for egress illumination requirements. (IBC Section 107.2.3, 1006 & 1008.1.6) 2. Exiting plan shows the means of egress passing through the storage and shop area. The means of egress shall not pass through storage rooms. Show a method of separation (wall) to allow for egress out that door. (IBC 1014.2 #4.) 3. Please provide an occupant load calculations in a table for this tenant. 4. Provide plan sets where all sheets shall have wet stamp and signature on each sheet by the design professional in charge. Electronic copies shall not be approved. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accented through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 If you have any questions, I can be reached at (206)431-3655. Sincerely, c Bill Rambo2 Permit Technician File No. D15-0230 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0230 DATE: 10/02/15 PROJECT NAME: NC MACHINERY - BLDG 3 SITE ADDRESS: 17025 W VALLEY HWY Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: k--S bffi G [0-b-c�— Building Division Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Fire Prevention ❑ Structural ❑ Planning Division ❑ Permit Coordinator ❑ DATE: 10/06/15 Structural Review Required ❑ 1MEN11:9 DUE DATE: 11/03/15 Approved with Conditions Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0230 DATE: 09/09/15 PROJECT NAME: NC MACHINERY SITE ADDRESS: 17025 WEST VALLEY HWY X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: Revision # before Permit Issued Revision # after Permit Issued 004 AJ 0111 AV\ Awc � 13�� ho. al `lo VV g Division Building ) � Fire Prevention e ention � Planning Division p M a�to �tOr Public Wo ks Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 09/10/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/08/15 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg fr Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION' S A MYTTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 0" --30 Plan CheckTermit Number: D 15 -0230 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 CITY OF T u ►: W I L A ❑ Revision # after Permit is Issued LC I 0 12015 ❑ Revision requested by a City Building Inspector or Plans Examiner PERMIT CENTER Project Name: NC Machinery. — P 5 5 a Project Address: 17025 W Valley Hwy Contact Person: 1 O W 30 hN50P Phone Number: 2n` S 22'416 s Summary of Revision: 441— CVvJYv $WVb'f -- Veywr UnAw cony- eu pmp 0 You �> L4W FM I t_w IM . Sty 0 LV 6 4, f:.11W b W7- "TS 4-2 E6",6s J')J 1) SKO? l�I' V/VQ !9 4-3 p Lc w,V S cy eVVW ?KDV 11).F0 U4-- was- 3mo,r eft vinno Sheet Number(s): A-w "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ❑ Entered in TRAKiT on \anplications\forms-applications on lineVevision submittal HHJ Inc Page I of 2 Homc Inicio en Ispariol Contact Safety AC� Washington State Department of kh Labor & Industries HHJ Inc Owner or tradesperson Principals Hansen, Garth Roger, PRESIDENT Doing business as HHJ Inc WA UBI No. 603 093 299 License Search L&I A-% Index Help My Secure L&I Claims & Insurance Workplace Rights Trades & Licensing P.O. Box 27451 FEDERAL WAY, WA 98093 253-380-3801 KING County Business type Corporation Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor .................................. Active. Meets current requirements. License specialties GENERAL License no. HHJINI'890D5 Effective — expiration 03/25/2011— 03/25/2017 Bond ................ Western Surety Co $12,000.00 Bond account no. 71083925 Received by L&I Effective date 03/25/2011 03/25/2011 Expiration date Until Canceled Insurance ............... _ ........... Associated Industries Ins Co 1 $1,000,000.00 Policy no. AES103360100 Received by L&I Effective date 12/31/2014 01/01/2015 Expiration date 01/01/2016 Insurance history Savings ...................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ............ _......................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ....................................................... No license violations during the previous 6 year period. ARCHITECTS PLLC 601 St. Helens �i Tacoma, Washington 98402 W to Phone: (253) 922-4168 O w ZONE: C/LI - Commercial Light Industrial �_ z j 1 2014 N TIONAL ELECTRICAL CODE NFPA 70 SEE DEPT. OF L& I i O�3 _O Project Title AND ER Q\DUSTRIAL Z � I ( )- N �' �° 4 r.,- .� raR,�R,� PARCEL NUMBER: 2523049046 ADOPTION/AMENDMENTS ~ Tot�� SgpAn- ►T P�R�11i' l ll n review a al is D v I `L PA NO. a g t SEISMIC DESIGN CATAGORY: D ICC / ANSI A.117-2009 CCESSIBLE AND USABLE BUILDINGS AND FACILITIES InEQUIRED FOR: IaP et►b ep errors end ornissian$. WITH STATE AME DMENTS (4-1-08) JJ Approval of, con on Z I�C, MACHINERY �,�, P documents does not authorize o I SITE AREA: 523,156 SF (Ndctn '` 19 violation of an ordinance. R R OFFICE a �J'= ted tide or Ordin PSS 0 C • -$: 4 � ` � a _ IBC OCCUPANCY CLASS: B - OFFICE (enlarged) SEPARATE PERMITS Of proved Field a Rd COnditi�l8 iS aCltno je 0 fit' r, le "eQ Govtkot �- Is ' S1 - SHOP (reduced) " kK" THE FOLLOWING SEPARATE PERMIT SUBMITTALS TO BE PROVIDED BY THE O srcok,tt ';;.< 4.IG Arcs a x +>,y IBC 406.8 -Table 508.4 -non-rated between B & S1 FWDto z SELECTED DESIGN -BUILD SUBCONTRACTOR: By: IBC CONSTRUCTION TYPE: V-B ,per wglllM we y w 1. O titi}CZMECHANICAL DRAWINGS D�®: FIRE SPRINKLER: NON SPRINKLERED'•1' ,�,,'• c 2. PLUMBING DRAWINGS City {-I-uwa FLOOR AREAS: OVERALL BLDG: p - t, - _ BUiLDI�G DIViSt® I uovl°� s • 4 FIRST FLOOR: 5,647 3. ELECTRICAL DRAWINGS 23.65 Acres � � 4 I' tv. z �j MEZZANINE: 682 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE: W f TOTAL BLDG: 6,329 SF 17025 West Valley HWY I PROJECT THE REGISTERED DESIGN PROFESSIONAL IN CHARGE ARCHITECT OR ENGINEER Increase office area - B: 1,522 SF B U I LD I � F I E D E PT■ OTES ( Tukwila WA 98188 �y. LOCATION Decrease shop area - S1: 1,522 SF SEALING THE DRAWING) SHALL BE RESPONSIBLE FOR REVIEWING AND COORDINATING O THE SUBMITTAL DOCUMENTS PREPARED BY OTHERS, INCLUDING PHASED AND U DEFERRED SUBMITTAL ITEMS FOR COMPATIBILITY WITH THE DESIGN OF THE BUILDING 1. PROVIDE FIRE EXTINQUISHERS WITH A MINIMUM RATING OF 2A-10B:C IN ACCESSIBLE I "�� "�• � � � PER IBC 107.3.4 (2012) � Sheet Title j�._ Ii i •K;; AREAS AT THE EXIT DOORS OR IN THE PATHS OF EXIT TRAVEL. TOP OF FIRE EXTINGUISHER E1514ERGY S ARY CABINETS SHALL EE 48". DOCUMENTS FOR DEFERRED SUBMITALLS SHALL BE SUBMITTED TO THE DESIGN o COVER2. PROVIDE MEANS OF EGRESS ILLUMINATION PURSUANT TO IBC 2012 SECTION 1006 AND PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD I ` WSEC 2012 EXIT SIGNS PURSUANT TO IBC 1011. ILLUMINATION OF THE EXIT PATHWAYS SHALL BE THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED Z j a - C101.4.3 ADDITIONS, ALTERATIONS, RENOVATIONS OR REPAIRS PROVIDED WITH AMINIMUM OF ONE FOOT-CANDLE AT THE FLOOR LEVEL. EXIT SIGNS SHALL SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND HAVE BEEN FOUND TO BE IN O I f4: i i ADDITIONS, ALTERATIONS, RENOVATIONS OR REPAIRS TO AN EXISTING BUILDING, BUILDING BE INSTALLED WHEREVER NECESSARY TO CLEARLY INDICATE THE DIRECTION OF EGRESS GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. THE DEFERRED 1 SYSTEM OR PORTION THEREOF SHALL CONFORM TO THE PROVISIONS OF THIS CODE AS FROM ANY PORTION OF THE BUILDING. THESE REQUIREMENTS ARE SUBJECT TO FIELD SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE DESIGN AND THE SUBMITTAL W � INSPECTION AND APPROVAL PRIOR TO OCCUPANCY. Y RELATE TO NEW CONSTRUCTION WITHOUT REQUIRING THE UNALTERED PORTION OF DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. � � THEo - --- - r� THE EXISTING BUILDING OR BUILDING SYSTEM TO COMPLY WITH THIS CODE. 0 ; • r. ''`t SN • n C_a iy.rK,ylLUI { t CgRfigbRAwl'F_ M: �_.. ...... ....__•__ ...,--,,..i...__.. __.. (�n 'Rlrit fO+Y <..!! i. C�N!'t�Aif'• Gu0 Ufa` Z 31 A Acres 1 p �F E 44.1' Lot s EXISTING BUILDING SHELL: (metal building construction) � ( 44,t0 Acres Q ROOF R-30 BATT I r T H• WALLS R-19 BATT C®®E I E/S TY PLAIMco p EXTERIOR WALL FILL IN: (wood construction) WALLS R-21 BATT a DOORS U = 0.37 MAX Lu WINDOWS U = 0.38 MAX OCCUPANT LOAD m Project Number: , r«; >° `�� AREAS ALTERED AT EXTERIOR ENVELOPE WILL COMPLY WITH 2O12 WASHINGTON STATE NAME OCC TYPE AREA OCC F OCC L _ __.__________.. �y Q . �„u r tI e r T a fr �P e*°t'` v - :. __.._ - t � 2 ENERGY CODE. (UNALTERED AREAS NOT REQUIRED TO COMPLY) R ryY�GiJ FOR pq,r V .,n•+ . .ratn I} ....... U \ T . _ � 1 srl' U) , . 4r/ CWf{tl IVCE CD Date: 08/30/15 AT NEW EXTERIOR JOINTS AROUND NEW WINDOWS AND NEW DOOR FRAMES, NEW OPENINGS FIRST FLR P z BETWEEN WALLS AND FOUNDATION, BETWEEN WALLS, ROOF AND WALL PANELS: NEW OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS AND ROOFS; AND ALL OTHER NEW OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED OR WEATHERSTRIPPED TO LIMIT AIR LEAKAGE. NEW FIXED WINDOWS SHALL BE TIGHT FITTING WITH GLASS RETAINED BY STOPS WITH SEALANT OR CAULKING ALL AROUND. ABBIREVIATIONS SY BOL LEGS D A-- H -- R -- ACM ALUMINUM COMPOSITE HC HOLLOW CORE RB^ RUBBER BASE ^ • ^^ l N J WINDOW TYPE LEGAL DESCRIPTION PROJECT NAME: NC -OFFICE AREA EXPANSION 2012 INTERNATIONAL EXISTING BUILDING CODE AT PSSR BUILDING 2012 INTERNATIONAL BUILDING CODE WITH STATE AMENDMENTS (7-1-13) PARCEL # 2523049046 PROJECT DESCRIPTIOWEXISTING INSULATED METAL BUILDING CONSTRUCTION. PORTION OF GOV LOT 6 IN SW 1/4 OF SECTION 25-23-04 LY WLY OF STATE EXPAND EXISTING WEST END OFFICE AREA INTO SHOP 2012 INTERNATIONAL MECHANICAL CODE WITH STATE AMENDMENTS (7-1-13) HIGHWAY NO 5-M LESS N 200 FT AREA ON EAST END OF BUILDING. ADD INSULATED FURRED WALLS TO EXTERIOR WALLS, ADD OFFICE ROOMS AND OPEN 2012 INTERNATIONAL FIRE CODE WITH STATE AMENDMENTS (7-1-13) VIC11111111ITY MAP OFFICE AREA, REVISE STAIR TO STORAGE ABOVE. 2012 NFPA 30 -FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE ADDRESS: 17025 WEST VALLEY HWY, TUKWILA, WA 98188 2012 UNIFORM PLUMBING CODE WITH STATE AMENDMENTS (7-1-13) ' JURISDICTION: CITY OF TUKWILA van-W map 2012 WASHINGTON STATE ENERGY CODE (WAC 51-11 C) (e)CONF A (e) 203 SF 15 13.5 (e)ELEC S-1 (e) 75 SF 300 0.2 (e)OFF. B (e) 148 SF 100 1.5 (e)OFF. B (e) 146 SF 100 1.5 (e)OFF. B (e) 146 SF 100 1.5 (e)OFF. B (e) 146 SF 100 1.5 (e)OFF. B (e) 239 SF 100 2.4 (e)OPEN OFF. B (e) 1161 SF 100 11.6 (e)SHOP S-1 (e) 743 SF 300 2.5 OFF. B 139 SF 100 1.4 OFF. B 140 SF 100 1.4 OFF. B 157 SF 100 1.6 OPEN OFF. B 767 SF 100 7.7 SHEETINDEX COVER COVER D201 FIRST FLOOR DEMO & CLEAN-UP PLAN A101 SITE PLAN A201 FIRST FLOOR PLAN A211 SECTIONS & ENLARGED STAIR PLANS A301 DOOR/ROOM SCHEDULE & DETAILS Opy w z OCT 0 % 201� � Drawn: Author !I w 48" 45 3/4" (e) HM City of TUkWlla Q Checked: _ RATED BUILDING DIVISION c� DOOR &�, Z F:\Job#\2015\NC-PSBR Bldg EMERGENCY' k y Remodel\REVIT\NC PSSR.rvt LIGHT fi I File: `1 W 3 occupant load ��" Z Scale: As indicated 00 I Id �" x ......... �U­Ea�__­_=_.._.... .'.... : :h._.0 ,,' .. _ ._ .... O -_. ____�- Tonti-c nccTie� quo %nie1 I_. ___. - n REVISIONS: INSTALL F -- TPD TOILET PAPER DISPENSER P -- F/GL FIBERGLASS TRWL TROWEL FINISH ENT CONCRETE FF FACTORY FINISH PCC PORTLAND CEMENT TSCD TOILET SEAT COVER DISPENSER �� 1 DETAIL CALLOUTLo� �,rt man. mg Uivislon of DGD iovec VVW�VII�f� N� >3. �� 6 r2 x x .,.,. : ����� ��3 �€ ... OF _.. OF _ � OFF.. � r i .,. W OFF, � ;;.-. e ©FF. :, .,�. e OFF � . e O :_� e ,:; < _.. (JFF B E: ..'� W U A SE FRP FIBERGLASS REINFORCED PLAM PLASTIC LAMINATE TTP TAPE, TEXTURE & PAINT A1.014-1 „< 144SF _ M. O � STATEF WASHINGTON PANEL PLYWD PLYWOOD UW. FT FIRE TAPE ONLY ON brts" I Y -r- A rUL rUL10nw UL UNUERVVRRERS LAC3UYV- WRY Q GWB PR PAIR V -- G -- PRE-FAB PRE -FABRICATED VCT VINYL COMPOSITION TILE PROVIDE NEW O IITT A1.01 1 ELEVATION CALLOUT EXIT SIGN XIT SIGNS GBU GLASS BLOCK UNIT PRE -FIN PRE -FINISHED VWC VINYL WALL COVERING FABRIC GL GLASS PPATCH, REPAIR &PAINT w -- CODE - FIRST FLOOR FIRE / LIFE SAFETY GLB GLU-LAM BEAM PT PRE -PRIME &PAINT WD WOOD W GRP GROUP PTD PAPER TOWEL DISPENSER 1/16" = V-0" W w GWB GYPSUM WALL BOARD PW 1-1/8" PLYWOOD WAINSCOT W COVER BIDl?�1M. - ?eIT 5e-r -- 4 Dt s- 0 23 z0 [A211 REMOVE — WALL FOR RELOCATED DOOR DEMO — ASPHALT I A211 I 5 r FIRST FLOOR DEMO & CLEAN-UP PLAN 1/8" = 1 1-011 T T 5 8 7 6T T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DEMO (E) 1-HR WALL TO BTM OF BEAM (E) 1 -HR WALL RELOCATE (E) TO REMAIN UNIT HEATER (E) UPPER STAIR RUN AND LANDING TO REMAIN (E) STAIR RUN FRAMING TO BE RELOCATED 11 T 1­ 1 l T 6 A DEMO OH DOOR & TRACK DEMO OH TRACK (no door) An ... REVIEWED FOR ' bObF. COMPLIANCE APMOVED OCT 0 7 2015 City of TuWIa MIJILOING DIVISION -I 0 I TI AREA i r ,> I /f i f F 111 = 40'-011 1 F.: F-VEWEED FOR i,�IE.COMPLIANCE , APPROVED OCT 0 7 2015 CRY of TuWAIa UIWING DIVISION 0.1t.5 6 ARCHITECTS PLLC 601 St. Helens Tacoma, Washington 98402 Phone: (253) 922-4168 Project Title NC MACHINERY - PSSR OFFICE 117025 West Valley HWY Tukwila, WA 98188 Sheet Title c SITE PLAN Project Number: Date: 08/30/15 Drawn: Author Checked: Checker F:\Job#\2015\NC-PSSR Bldg Remodel\REV IT\NC-PSS R.rvt File: Scale: V. = 40'-0" REVISIONS: Rev# Rev Date Description C,"T"Y COI' Tuf.Vti'ILA UCT 0 12015 PERMIT CENTER STA1 E Oi= VVASF;Ii�lGTON ■ I 1 PR91,1DE — 4'x5ONC _ STO P z 2 ,TED SLOPE ASHPALT TO STOOP, 1:12 MAX :8.� � ��i� j 6 i�5i '�4 i� '\3.1 i�2 ,; 10 4 14U' - U.. 20'-0" 20'-0" 20'-0" t 20'-0" 20-0" 20'-0" 20'-0" PROVIDE 8" REINF. DRY CMU WALL BEHIND DIESIEL EQ EO PUMP/TANK (FIELD VERIFY LENGTH & HEIGHT) ......................R-21 NEW SIDING TO ............ _..,> MATCH EXISTING I »., BELOW 2 A211 9' - 10 1 /4" 10, - 0" FIRST FLOOR PLAN 1 /8" = 1'-0" FIRST FLOOR REFLECTED PLAN 1 /8" = 1 t-Ott A211 C A211 1V-13/4" 9'-0"+/- 0 O T GENERAL NOTES 1 DIMENSIONS ARE TO GRID, FACE OF STUD, OR FACE OF (E) WALL 2 RUN NEW WALLS TO 6" ABOVE ACT CEILING, BRACE TO STRUCTURE 3 (E) ACT CEILING AND LIGHTS TO REMAIN, DO NOT DAMAGE 4 CONTRACTOR IS RESPONSIBLE FOR ADJUSTMENT AND RELOCATION OF ALL CEILING FIXTURES, WHEREVER THERE IS A CONFLICT WITH NEW WALLS, INCLUDING AIR VENTS AND SPRINKLER / SENSOR HEADS. 5 FOR WALL ASSEMBLY TYPES, SEE A301 10 FOR FIRE SPRINKLER LAYOUT, SEE FIRE SPRINKLER DRAWINGS 11 FOR ELECTRICAL LAYOUT, SEE ELECTRICAL DRAWINGS 12 FOR MECHANICAL LAYOUT, SEE MECHANICAL DRAWINGS -------------- B - ... PLAN & CEILING LEGEND (E) WALL EXTEND NEW WALLS TO 6" ABOVE ACT CEILING, BRACE TO UNDERSIDE OF DECK o NEW WALL, FOR ASSEMBLIE SEE A301 GWB NEW ACT CEILING match (e) act and layout (E) ACT CEILING ._._.._ ........................... (E) RECESSED 2x4 LIGHT FIXTURE UZINEW RECESSED 2x4 LIGHT FIXTURE similar to existing NEW PENDANT 2-LAMP LIGHT FIXTURE 0 RELOCATE (E) LIGHT FIXTURE REVtWEDFOR ODE COMPLIANCE APP OVED OCT 0 7 2015 City of Tukwila BUILDING DIVISION BID SET � •r' r •, I _ WA LL�BRAC_E� /1 " PER 3A2 1 >: -t— W4 R-21 I .r •a �N EW ACT CEILING :UV3� - -- M :O �R-11_ �r I i \ iS 9 - W3 el (E) 5" CONCRETE .............. _ . _ .................................................. ......... _ ER CAPS i SECTION N/S (assulmed) 5 (E) ROOF R-30 BATT - (E) WALLS R-19 BATT WALL FILL IN: METAL SIDING, WOOD FRAME w/ R-21 BATT INSUL, NORTH ELEVATION 1 /8" = 1'-0" A 7 A211 I R-21 BLANKET INSUL, ' ! AROUND BEAM, SEAL l TO (e) BLANKET INSUL WALL TYPE PER PER PLAN I' f NOTE: WALUCEILING AND WALL/FLOOR ATTACHMENTS SHALL ACCOMODATE A MIN. OF 5 PSF APPLIED PERPENDICULAR TO WALL )�ALL STEEL BEAM2 - 1-0 16 GA. CONT. DEFLECTION TRACK FASTENED TO BEAM @ 24" oc MAX ATTACH EACH SIDE OF STUD 8" CMU WALL PROTECTION (E) SLANTED - COLUMN EXTEND GWB TO EXTERIOR METAL SIDING, BOTH SIDES COLUMN WRAP 1 1 /2" = 1'-0" _ ROOF PLT 16' -10" (E) WALLS METAL SIDING 8" PURLINS R-19 BLANKET INSULATION MEZZANINE 10 - 0 5/8 O E GAS PUMP & ARM BEYOND NEW CMU WALL BEYOND E BOLLARDS BEYOND i FIRST FLR 0 -0 grade beam =2'-0" _ ROOF -LT 16' - 10" _ MEZZANINE 10, - 0 5/8" _ FIRST FLR 0'-0" C 9 CT . ...... .... I Y` PROVIDE 2x4 42 ' i' HI HALF WALL :�.• . GWB ONE SIDE I F W3 I N I , , I W 3 i- - •M e - I N • i N V I r , N oo , - - t , 1.5" "OOD RELOCATED WOOD HANDRAIL STAIR RUN STAIR SECTION 1 /4" = 1'-0" PROVIDE NEW CONC STOOP 0'- 4 1 /8" 4'-03/8" 4'-0" VERIFY DIM FOR (E) STAIRS (V .. �05I YPI II ROOF PLT - -16' La -10" I) (E) POSTS FOR UPPER 1.5" DIA WOOD STAIR RUN E STAIR & HANDRAIL HANDRAILS BOTH „ aU BEYOND SIDES, 36 HI . u 1/2 PLYWOOD, ATTACH TO — C PURLINS OR PROVIDE 1.5 RELOCATE Ery jcl� LOWER STAIR RUN . MEZZANINE 10 - 0 5/8 PROVIDE NEW ...:... _ LANDING & POSTS (match existing) _ — — GWB WALL FIRST FLR of -Oil 7 T T - I J I I I I I i I I - I I I I I I I I I I i I � I I R, .,.:..h..,:».:.»..».....�.».,.,.•,::.�:»:., :..»mow»».».,»:..........,I«,».,..:�»«.�,:ro.�,,,,:,»:. .,,:wF.,. — -. ADD NEW POSTS & LANDING B A211 5 ENLARGED STAIR PLA ROOF PLT 16' -1Oil JIEZZANINE 10'-05/8" FIRST FLR Au 0'-0" 1 /4" = 1'-011 . WEST ELEVATION E 1 /8" = 1'-0" R-21 ,i Z J METAL DECK STRUCTURE CONC. STRUCTURE Q 2 1/2" 20 GA. STUD (MIN.) O 4' - 0" O.C. ALT. SIDES W (FROM BELOW) �'- W U W3 (2) #10 S.N.S. AT EACH BRACE USE (2) APPROVED HILTI CONC. MECHANICAL FASTENERS R-11 RE WED FOR OD'E COMPLIANC APPROVED (2) #10 S.M.S. AT EACH BRACE x` 2 1/2" 20 GA.STUD (MIN.) OCT Q 7 20�5 j 4' - 0" O.C. ALT. SIDES TO STRUCTURE ABOVE DBL 2x4 PLATE Cif ofTukMIa CEILING HT. BUILDING DIVISION - %`"` REFER TO REFLECTED 9f WALL TYPE PER PLAN NOTE: ' WALLS TO RESIST 5LBS. PERPENDICULAR LATERAL LOAD 7 (REFER TO SPECS.) 30 PARTITION BRACE TO STRUCTURE 1 1 /2" = T-0" � 'I 1 *14 1 u 5/8" TYPE'X' GWB VAPOR BARRIER (office side) 2x6 STUDS @ 16" OC R-21 BATT INSULATION 5/8" TYPE'X' GWB - — — — — — — — — — — — — — — — — — — — — —.— — — — ,...... _....., .-._........., 2x6 STUDS w/GWB 3" = 1'-0" 5/8" TYPE'X' GWB 2x4 STUDS @ 16" OC 3" SOUND BATT INSULATION 5/8" TYPE 'X GWB Y t ......... . . .. ....its ,k., I 1, i� , ) 1A10 2x4 STUDS w/GWB EACH SIDE V V L I 3" = 1'-0" IAIQ 2x FURRING w/GWB ONE SIDE V V V 1 3" = 1'-0" METAL SIDING - MATCH (E) WRB 1/2" PLYWOOD SHEATHING 2x6 OR 2x8 STUDS @ 16" oc R-21 BATT INSULATION W4 EXT - METAL SIDING w/2x WOOD STUD WALL 311 -1-0 11 L HEADER REINFOR( ANGLE EXT-HM DOOR @ MTL SIDING 3" = 1'-0" EXT HM DOOR THRESHOLD 3" = 1'-0" (E) GIRT DOOR GUTTER TRIM DOOR ANCHOR PLATE DBL RABBET HM 4 3/4" X 2" DOOR FRAME DOOR NOT SHOWN WALL TYPE I PER PLAN CONT SEALANT, BOTH SIDES FILL FRAME WITH SOUND INSULATION RATED OR NON -RATED DOOR & FRAME PER SCHEDUL WD STUD - WOOD DOOR HEAD / JAMB SIM 3" = 1'-0" YPE AN ,OR & FRAME PER HEDULE WD DR @ WD STUD WALL JAMB/HEAD SIM 3" = 1'-0" DOOR SCHEDULE DOOR ROOM �DOOR#iWIDTH DOOR I FRAME DETAILS FIRE I RATING HARDWAR E COMMENTS I HEIGHT THICKNESS I TYPE I MATERIAL FINISH GLASS I TYPE IMATERIALI FINISH I HEAD I JAMB I SILL FIRST FLR Existing OPEN OFFICE (e)12 3'- 6" 7'- 0" 0'- 1 3/4" A HM --- --- 1 HM --- --- --- --- RELOCATE (E) SHOP (e)l 5a 10' - 0" 12' - 0" 0'- 2" NO WORK OPEN OFFICE (e)l5b 10' - 0" 12' - 0" 0' - 2" DEMO OPEN OFFICE (e)15c 3' - 0" 7' - 0" 0'- 1 3/4" A HM --- --- 1 HM --- --- --- --- RELOCATE OPEN OFFICE (e)16 3'- 0" 6' - 8" 0' - 1 3/8" DEMO New Construction (E) SHOP 15d 3' - 0" 7' - 0" 0'- 1 3/4" A HM PT --- 1 HM PT 4/A301 ---. 3/A301 --- 4 RELOCATED / INSUL CLOSET 16 3'- 0" 6' - 8" 0'- 1 3/8" A SCWD S&V --- 2 WD S&V 1/A301 ' 1/A301 --- --- 3 OPEN OFFICE 101 T - 6" 7' - 0" 0'- 1 3/4" A HM PT --- 1 HM PT 2/A301 2/A301 3/A301 SIM --- 4 RELOCATED / INSUL OFFICE 1 105 3'- 0" 6' - 8" 0'- 1 3/8" A SCWD S&V --- 2 WD S&V 1/A301 1/A301 --- --- 2 OFFICE 2 106 3' - 0" 6' - 8" 0'- 1 3/8" A SCWD S&V --- 2 WD S&V 1/A301 1/A301 --- --- 2 OFFICE 3 107 T - 0" 6' - 8" 0'- 1 3/8" A SCWD S&V --- 2 WD S&V I 1/A301 1/A301 --- --- 2 DOOR SCHEDULE GENERAL NOTES 1 INTERIOR COMMERCIAL WOOD DOORS SHALL BE SOLID CORE, WITH WOOD FRAME 3 PROVIDE ACCESSIBLE LEVER HANDLES AT ALL NEW DOORS 4 PROVIDE BLOCKING FOR DOOR STOPS. 5 VERIFY HARDWARE & KEYING WITH OWNER. 6 FORCE FOR INTERIOR SWINGING EGRESS DOORS NOT TO EXCEED 5 POUNDS (22N). 7 FORCE FOR OTHER DOORS: DOOR LATCH SHALL RELEASE WHEN SUBJECTED TO 15 POUND FORCE (67N). 8 FORCE FOR OTHER DOORS: 30 POUNDS (133N) TO SET DOOR IN MOTION. 15 POUNDS (67N) TO SWING DOOR TO FULL OPEN POSITION. 9 SEE HARDWARE SCHEDULE. DOOR TYPES FRAME TYPES 0' 0' - 8" GLAZING PER vv v / SCHEDULE — u, C� 10" KICKPLATE @ ACCESSIBLE O ROUTE DOORS O O O WINDOW & RELITE TYPES 2'-0" VERIFY — VERIFY GL-3 GL-1 cr M > v w > ih > tY (V ; LEVEL Ot R01 LEGEND - OPENING TYPES 1/4" = 1'-0" 0'-2" GLASS TYPES GL-1 INTERIOR DOORS AND RELITES: SINGLE PANE OF CLEAR SAFETY GLASS. GL-2 EXTERIOR STOREFRONTS: INSULATING GLASS UNIT WITH CLEAR FLOAT GLASS EXTERIOR PANE AND CLEAR FLOAT GLASS INTERIOR PANE. GL-3 EXTERIOR DOORS AND WINDOWS: INSULATING GLASS UNIT WITH CLEAR SAFETY GLASS EXTERIOR PANE AND CLEAR SAFETY GLASS INTERIOR PANE. HM WD FRAME O FRAME O DOOR HARDWARE GROUPS DOOR SCHEDULE ABBREVIATIONS ALUM ALUMINUM FF FACTORY FINISH HM HOLLOW METAL INSUL INSULATED MNFR MANUFACTURER PT PAINT S&V STAIN & VARNISH (match existing) SCWD SOLID CORE WOOD (match existing) STL STEEL WD WD GROUP HARDWARE 1 LEVER LATCH SET (NO LOCKS), CLOSER 2 LEVER LOCKSET 3 LEVER LATCH SET (NO LOCKS) 4 LEVER LOCKSET, CLOSER 5 PUSH/PULL HARDWARE, KEY LOCK, CLOSURE, ACCESSIBLE THRESHOLD, WEATHERSTRIPPING FINISH SCHEDULE... (E), (e) EXISTING MATERIAL OR FINISH ACT ACOUSTIC CEILING TILE CONC CONCRETE CPT CARPET CT CERAMIC TILE CTCB CERAMIC TILE COVE BASE DEMO DEMOLISH FF FACTORY FINISH GWB GYPSUM WALL BOARD MNFR MANUFACTURER PLAM PLASTIC LAMINATE PREP PREP FOR PAINT, GWB-REPAIR HOLES AND CRACKS PT PAINT RB-4 RUBBER BASE, 4" RB-6 RUBBER BASE, 6" STN STAIN SV SHEET VINYL SVCB SHEET VINYL COVE BASE VCT VINYL COMPOSITION TILE WB WOOD BASE ROOM SCHEDULE - EXISTING ROOM # ROOM NAME FLOOR BASE NORTH EAST SOUTH WEST CEILING COMMENTS MAT FIN MAT FIN MAT FIN MAT FIN MAT FIN MAT FIN MAT FIN FIRST FLR (e)01 EN1RY VP MNFR RB-4 VP OPTIONAL (e)02 COIJF CPT MNFR RB-4 (e)03 ELEC CPT MNFR RB-4 (e)04 OFFICE 1 CPT MNFR RB-4 (e)05 MEWS SV MNFR RB-4 (e)06 WOMENS SV MNFR RB-4 (e)07 COFFEE VP MNFR RB-4 VP OPTIONAL (e)08 OFFICE 2 CPT MNFR RB-4 (e)09 OFFICE 3 CPT MNFR RB-4 (e)10 OFFICE 4 CPT MNFR RB-4 (e)l1 OFFICE 5 CPT MNFR RB-4 (e)12 OPEN OFFICE CPT/VP MNFR RB-4 VP OPTIONAL (e)13 CLOSET VP MNFR RB-4 VP OPTIONAL (e)15 SHOP (e)CONC --- --- 5 DOAECb (e)16 CLOSET (e)CONC --- RB-4 c; rr MEZZANINE (e)21 MEZZ STOR (e)PLY --- --- NO WORK H ROOM SCHEDULE - NEW CONSTRUCTION U i BDII ROOM # ROOM NAME FLOOR BASE NORTH EAST SOUTH WEST CEILING COMMENTS MAT FIN MAT FIN MAT FIN MAT FIN MAT FIN MAT FIN MAT FIN FIRST FLR 101 OPEN OFFICE CPT/VP MNFR RB-4 MNFR (e)GWB/GWB PT/PT --- --- GWB PT GWB PT ACT MNFR 105 OFFICE 1 CPT MNFR RB-4 MNFR GWB PT GWB PT GWB PT GWB PT ACT MNFR 106 OFFICE 2 CPT MNFR RB-4 MNFR GWB PT GWB PT GWB PT GWB PT ACT MNFR 107 OFFICE 2 CPT I MNFR I RB-4 I MNFR GWB PT GWB PT GWB PT I GWB I PT ACT MNFR WED FOR COMPLIANCE )kOVED 07 2015 of Tukwila IG DIVISION