Loading...
HomeMy WebLinkAboutPermit D15-0231 - CASCADE VIEW ELEMENTARY SCHOOL - ART AND INTERVENTION ROOMSCASCADE VIEW ELEMENTARY SCHOOL - ART ROOM 1360132 ND AVE s D15-0231 City of Tukwila ' Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT Parcel No: 1623049038 Permit Number: D15-0231 Address: 1360132ND AVE S Issue Date: 10/22/2015 Permit Expires On: 4/19/2016 Project Name: CASCADE VIEW ELEMENTARY SCHOOL - ART ROOM Owner: Name: TUKWILA SCHOOL DISTRICT Address: 4640 S 144TH ST, TUKWILA, WA, 98168 Contact Person: Name: JIM THOMAS Address: 5005 3RD AVE S, SEATTLE, WA, 98134 Contractor: Name: MCKINSTRY ESSENTION LLC Address: 5005 3RD AVE S, SEATTLE, WA, 98124 License No: MCKINEL874CL Lender: Name: HUB INTERNATIONAL NW Address: 12100 NE 195TH ST, STE 200, BOTHELL, WA, 98011 Phone: (206) 763-4819 Phone: (206) 762-3311 Expiration Date: 2/13/2017 DESCRIPTION OF WORK: DIVIDE EXISTING ROOM INTO TWO ROOMS. SEPARATE HVAC SYSTEM AND PROVIDE NEW CONTROLS. REBALANCE HVAC. RELOCATE LIGHTING FIXTURES AS REQUIRED DUE TO SEPARATION AND INSTALL SEPARATE CONTROLS FOR EACH ROOM. INSTALL NEW FIRE SPRINKLER AND FIRE ALARMS. Project Valuation: $98,000.00 Fees Collected: $2,540.98 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Occupancy per IBC: Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: 125 Sewer District: NONE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per i and agree to the conditio s att hed to this permit. Signature: � Date. Print Name. D l'-c AA,, This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 4: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 3: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 5: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 6: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 7: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 8: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 9: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 10: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.6) 11: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 12: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1011.6.3) 13: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 17: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 15: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 14: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 18: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 19: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72-17.5.3.1) 21: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 22: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 23: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 24: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 25: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 26: In occupancies of Groups A, E, I and R-1 and dormitories in Group R-2, curtains, draperies, hangings and other decorative materials suspended from walls or ceilings shall be flame resistant in accordance with NFPA 701 or be noncombustible. Where required to be flame resistant, decorative materials shall be tested by an approved agency and pass Test 1, as described in NFPA 701, or such materials shall be noncombustible. Reports of test results shall be prepared in accordance with NFPA 701 and furnished to the fire code official upon request. (IFC 807.1, 807.2) 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 27: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 28: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 29: 'BUILDING PERMIT CONDITIONS' 30: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 31: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 32: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 33: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 34: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 35: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 36: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 37: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 38: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 39: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 40: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 41: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 1400 FIRE FINAL 0409 FRAMING 0406 SUSPENDED CEILING CITY OF TUKW_ I Community Development Department • Public Works Department • Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:Hwww.TukwilaWA. Rov Building Permit No. Project No. Date Application Accepted: 0 Date Application Expires: _ use CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 1623049038 Site Address: 13601 32nd Ave S Suite Number: Floor: 1 Tenant Name: Cascade View Elementary School Art Room New Tenant: ❑ .....Yes No PROPERTY OWNER Name: Tukwila School District Address: 4640 S 144th St City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Jim Thomas w/ McKinstry Essention LLC Address: 5005 3rd Ave S City: Seattle State: WA Zip: 98134 Phone: (206) 763-4819 Fax: (206) 762-2624 Email: permits@mckinstry.com GENERAL CONTRACTOR INFORMATION Company Name: McKinstry Essention LLC Address: 5005 3rd Ave S City: Seattle State: WA Zip: 98134 Phone: (206) 762-3311 Fax: (206) 762-2624 Contr Reg No.: MCKINEL974CL Exp Date: 02/13/2017 Tukwila Business License No.: BUS-0994786 ARCHITECT OF RECORD Company Name: KMB Design Groups, Inc. Architect Name: Jeff Feeney Address: 828 7th Ave. SE City: Olympia State: WA Zip: 98501 Phone: (360) 528-2766 Fax: Email: JeffFeeney@KMBdesign.com ENGINEER OF RECORD Company Name: McKinstry Essention LLC Engineer Name: Kristina Sing Address: 5005 3rd Ave. South City: Seattle State: WA Zip: 98134 Phone: (206) 832-8054 Fax: Email: kristinas@McKinstry.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: HUB International NW Address: 12100 NE 195th St; Suite 200 City: Bothell State: WA Zip: 98011 H:,ApplicationslFor -Applications On Lin62011 ApplicationsTermit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATIO? 06-431-3670 - Valuation of Project (contractor's bid price) •: 111 Describe the scope of work (please provide detailed information): Existing Building Valuation: Divide existing room into two rooms. Separate HVAC system and provide new controls. Rebalance HVAC. Relocate lighting fixtures as required due to separation and install separate controls for each room. Install new Fire Sprinkler and Fire Alarms. Will there be new rack storage? ❑..... Yes JZ.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC IS` Floor 400 2nd Floor Yd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? El ....... Yes ....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0....... Sprinklers Z ....:..Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ....... Yes ❑ .......No If "yes, attach list of materials and storage locations on a separate 8-112 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑....... On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:NApplications�Forms-Applications On Line12011 ApplicationsTermit Application Revised - 8-9-1 l.docx Revised: August 2011 Page 2 of 4 bh PUBLIC WORKS"PERMIT INFOR PION — 206-433-0179 .�a. Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ... Water District #125 ❑ .. Highline ❑ .. Renton ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ... Valley View ❑ .. Renton ❑ .. Seattle ❑ ...Sewer Use Certificate ❑ ... Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ... Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ... Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ .. Right-of-way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut cubic yards ❑ .. Work in Flood Zone ❑ ...Total Fill cubic yards ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ .. Trench Excavation ❑ ...Traffic Control El.. Looped Fire Line ❑ .. Utility Undergrounding ❑ ...BackflOw Prevention - Fire Protection Irrigation " Domestic Water ❑ ...Permanent Water Meter Size... " ❑ ...Temporary Water Meter Size.. " ❑ ...Water Only Meter Size............ " ❑ ...Sewer Main Extension.............Public ❑ ❑ ...Water Main Extension.............Public ❑ FINANCE INFORMATION Fire Line Size at Property Line _ ❑ ...Water ❑ ...Sewer Monthly Service Billing to: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: WO# WO# WO# Private ❑ Private ❑ ❑ ...Deduct Water Meter Size " Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: City State Zip Day Telephone: City State Zip H:%Applications`,Forms-Applications On Lin62011 ApplicationsTermit Application Revised - 8-9-1 l.docx Revised: August 2011 Page 3 of 4 bh PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR PTHORIZED AGE T: Signatur?:Jilm�21Thomas Cf/ /Hel4i2x Print Na w/ McKinstry Essention LLC Mailing Address: 5005 3rd Ave S Date: 09/03/2015 Day Telephone: (206) 763-4819 Seattle City WA 98134 State Zip H:lApplications Forms -Applications On Line, 2011 ApplicationsTermit Application Revised - 8-9-11.docx Revised: August 2011 Page 4 of 4 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $2,540.98 D15-0231 Address: 1360132ND AVE S Apn: 1623049038 $2,540.98 DEVELOPMENT $2,466.38 PERMIT FEE R000.322.100.00.00 0.00 $1,492.05 PLAN CHECK FEE R000.345.830.00.00 0.00 $969.83 WASHINGTON STATE SURCHARGE 13640.237.114 0.00 $4.50 TECHNOLOGY FEE $74.60 TECHNOLOGY FEE �TOTAL FEES PAID ' . 1 • 1 R000.322.900.04.00 0.00 $74.60 $2,540.98 Date Paid: Friday, September 04, 2015 Paid By: MCKINSTRY Pay Method: CREDIT CARD 045856 Printed: Friday, September 04, 2015 8:38 AM 1 of 1 SYSTEMS ��Q INSPECTION RECORD. Retain a copy with permit 10 INS'P-KTION NO. PERMIT NO. CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 RIM is Projec sp Type OfA pe'C . o r-;r- Address: .3 S 2t,Z,�4e- Date Called: Special Instructions: Date Wanted: aj2L 211 Requester: Phone No: IRA-P—p-roved per applicable codes. Corrections required prior to approval. 0 Inspector: Date: HREINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECO 'RD. I ' Retain a copv with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISI ON 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type I ti n/ Address: Date Cilled: Special InItructions: AAA, Date Wanted: Requester: f Phone No: 0 Approved per applicable codes. El Corrections required prior to approval. spector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to.schedute reinspection. M NO INSPECTION RECORD Retain a copy with permit INSPECT PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspec 'on* C94 (At-aAk (&tp Addr6s: -30ta Date C91led: libel Special Instructions: Date Wanted: a.m. 10 - 4 — p.m. Re;Vster, Phone No: 2�0 (0 IV (o q ffef- IZA 8 Approved per applicable codes. rrections required prior to approval. 1:1 W. Co EMU,! 67AM0 a I I ME MA KATE WE J VA 9 M R I —w0- 000 - I -_ - N E MMINIff ANNUM FAM-1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedute reinspection. 01 (-X VA, a1Z INSPECTION RECORD Retain a copy with permit '0 INSPt%ZLDffNO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: citf e4A, Type or tion: Addres t72 �':O 3 Od eid, Date Called: Special Instructions: Date Wanted: a.m. / t) — (S— p.m. Req ber: q !IV Ph0jM , - _ -S '10-28- REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Z, INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: /� Type of Inspection: j;� A / /-//-A S P Address:- Contact Person: Suite #: _ .� g Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Ad Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:,,.�-__ f ''''� -;; Date: // f17 ��' Hrs.: f . $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. tsming Aaaress Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 RECEIVED CITY OF TWUKWILA OCT 2 8 2015 `3ERMIT CENTER �) � - �-llo I CITY OF TUKWILA OCT 2 8 2015 PERMIT CENTER bl6 02� 1 City of Tukwila Department of Community Development September 25, 2015 JIM THOMAS 5005 3RD AVE S SEATTLE, WA 98134 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D15-0231 CASCADE VIEW ELEMENTARY SCHOOL - ART ROOM - 13601 32ND AVE S Dear JIM THOMAS, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size l 1x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) All Structural Drawings and structural calculations sheets to be stamped (original signed wet stamp, not copied) by Washington State licensed architect, structural engineer or civil engineer. (BUILDING REVIEW NOTES) 1. Revise code notes on the plans to reference compliance with current 2012 codes. 2. All plan sheets shall be provided with wet stamp and wet signature on each sheet by the design professional in charge. Electronic copies shall not be approved. 3. Mechanical alterations shall be done with a separate mechanical permit and with mechanical plans and details. (Information only) Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)431-3655. Sincerely, Bill Rambo2 Permit Technician File No. D15-0231 6300 Southcenter Boulevard Suite #100 • Tukwila Washint; ton 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D 15-0231 DATE: 10/02/15 PROJECT NAME: CASCADE VIEW ELEMENTARY SCHOOL SITE ADDRESS: 1630132 AVE S Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Builb9ing Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 10/06/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/03/15 Approved ❑ Approved with Conditions d Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0231 DATE: 09/09/15 PROJECT NAME: CASCADE VIEW ELEM SCHOOL - ART RM SITE ADDRESS: 1360132ND AVE S X _ Original Plan Submittal Response to Correction Letter # DEPARTMENTS: Revision # before Permit Issued Revision # after Permit Issued BuildingDivision Fire Prevention Planning Divisio ® g a`ro Public WorkdN�s Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 09/10/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/08/15 Approved ❑ Approved with Conditions ❑ Corrections Required (corrections entered in Reviews) Notation: Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: hqp://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /0 _ F Plan ChecWPermit Number: D 15-0231 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued HEICEtd/Ep ❑ Revision requested by a City Building Inspector or Plans Examiner (-rry OF TUKWXp Project Name: Cascade View Elementary School PERMITCENTER Project Address: 1360132 Ave S Contact Person: d ArZKAr f 65"JtA �/Phone Number: aalo -103�- Cq`e Summary of Revision: 0Cf�Df 4l� s 61t' /'zdr4 S 14-P0471� j T s/d� r�Y 7, ��sr� l�ivsSfLf C 44a,!�jr, Ark r" L AC ,Z-mI T S M!.�- — de57 Sheet Number(s): A L L "Cloud" or highlight all areas of revision including d reVio C Received at the City of Tukwila Permit Center by: [Entered in TRAKiT on \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: MCKINSTRY ESSENTION LLC Page 1 of 2 Home Inicio en Espafiol Contact Safety Washington State Department of Labor & Industries MCKINSTRY ESSENTION LLC Owner or tradesperson ALLEN, DEAN CHARLES Principals ALLEN, DEAN CHARLES, MANAGER TEPLICKY, JOSEPH WILLIAM, MANAGER MOORE, DOUGLAS JAMES, MANAGER WA UBI No. 603 259 907 License Search L&I I $_? A-7 Index Help MY Secure L&I Claims & Insurance Workplace Rights Trades & Licensing PO BOX 24567 SEATTLE, WA98124 206-762-3311 KING County Business type Limited Liability Company Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ............................ _........................... _....... Meets current requirements. License specialties GENERAL License no. MCKINEL874CL Effective — expiration 02/13/2013— 02/13/2017 Bond ................. Western Surety Co $12,000.00 Bond account no. 929563205 Received by L&I Effective date 02/13/2013 01/22/2013 Expiration date Until Canceled Insurance .......... _ ....... _ .. Travelers Indemnity Company Th $2,000,000.00 Policy no. VTC2KC0564B9011ND14 Received by L&I Effective date 12/01/2014 01/31/2014 Expiration date 01/31/2016 Insurance history Savings ................. .. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts .............. No L&I.tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=603259907&LIC=MCKINEL874CL&SAW= 10/22/2015 MCKINSTRY ESSENTION LLC License Violations ............................................. _......... No license violations during the previous 6 year period. Page 2 of 2 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 706,165-00 ................................. Doing business as MCKINSTRY CO Estimated workers reported NIA L&I account representative (360)902-4817 Workplace safety and health Self Insured. This business is certified to cover its own workers' comp costs. No premiums due. Check for any past safety and health violations found on jobsites this business was responsible for. O Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603259907&LIC=MCKINEL874CL&SAW= 10/22/2015 f PROJECT INFORMATION DESIGN TEAM DRAWING INDEX DRAWING SYMBOLS DETAIL NUMBER OWNER ARCHITECT ARCHITECTURAL ac SHEET NUMBER WHERE DETAIL APPEARS A0.1 COVER SHEET TukWIa School District No. 406 KMB design groups, inc. p.s. A2.1 ENLARGED PLANS WALL SECTION DESIGNATION 4640 South 144th Street 828-7th Avenue S.E. Tukwila, WA 98168 Olympia, Washington 98501 SHEET NUMBER WHERE SECTION APPEARS Phone: (206) 901-7822 360.352.8883 Fax: 360.352.8853 Fax: (206) 901-8016 Craig McClelland BUILDING SECTION DESIGNATION craigmcclelland@kmbdesign.com Owner's Representative Elizabeth Glenn SHEET NUMBER WHERE SECTION APPEARS David Johnson, Maintenance & Operations Supervisor elizabethglenn@kmbdesign.com e-mail: Lohnsond@tukWIa.wednet.edu 1 ELEVATION NUMBER DESIGNATION PROJECT LOCATION 4 A71 :2—: DIRECTION IN ROOM SHEET NUMBER WHERE 3 ELEVATION APPEARS 13601 32nd Avenue South Tukwila, wa 98168 ® ROOM NUMBER FOR FINISH SCHEDULE ® DOOR NUMBER FOR DOOR SCHEDULE WINDOW TYPE WINDOW NUMBER xx CEILING DESIGNATION CEILING HEIGHT & AND BTWN BETWEEN (E) EXISTING FOS FACE OF STUD L ANGLE BUR BUILT-UP ROOF EA EACH FOW FACE OF WALL @ AT CAB CABINET EF EXHAUST FAN FP FIREPROOF ti CENTER LINE CFCI CONTRACTOR FURNISHED/ EIFS EXTERIOR INSULATION FR FIRE RESISTANT 0 DIAMETER CONTRACTOR INSTALLED AND FINISHING SYSTEM FRMG FRAMING FOOT (FEET) CJ CONSTRUCTION JOINT EJ EXPANSION JOINT FRT FIRE -RETARDANT -TREATED " INCH CL OR 4. CENTER LINE EL ELEVATION FS FAR SIDE d PENNY (NAILS) CLG CEILING ELEC ELECTRICAL FT FOOT(FEET) # POUNDS CLR CLEAR ELEV ELEVATION FTG FOOTING R PLATE or PROPERTY LINE CMU CONCRETE MASONRY UNIT EN EDGE NAIL GA GAUGE AB ANCHOR BOLT COL COLUMN . ENG ENGINEER GALV GALVANIZED A/C AIR CONDITIONING CONC CONCRETE EQ EQUAL GB GRAB BAR ACOUS ACOUSTIC(AL) CONN CONNECTION EQUIP EQUIPMENT GLB GLUE LAMINATED BEAM ACT ACOUSTICAL CEILING TILE CONST CONSTRUCTION ES EACH SIDE GWB GYPSUM WALLBOARD ACC ACCESSIBLE CONT CONTINUOUS EXP EXPANSION HB HOSE BIBB ADD ADDITIONAL CORR CORRIDOR EXIST, EXG EXISTING HC HOLLOW CORE / HANDICAP ADJ ADJACENT/ADJUSTABLE CTSK COUNTERSINK EXT EXTERIOR HD HOLD DOWN AFF ABOVE FINISH FLOOR CTR CENTER FA FIRE ALARM HDW HARDWARE ALUM ALUMINUM DBL DOUBLE FAB FABRICATE(ION) HDR HEADER ALT ALTERNATE DEPT DEPARTMENT FIN FINISH HGR HANGER APPROX APPROXIMATE DF DOUGLAS FIR / FDN FOUNDATION HORIZ OR H HORIZONTAL ARCH ARCHITECTURAL) DRINKING FOUNTAIN FE FIRE EXTINGUISHER HM HOLLOW METAL BD BOARD DIA OR 0 DIAMETER FEC FIRE EXTINGUISHER CABINET HR HOUR BLDG BUILDING DIAG DIAGONAL FF FINISH FLOOR HTG HEATING BLK BLOCK DN DOWN FHWS FLAT HEAD WOOD SCREW HTR HEATER BLKG BLOCKING DO DITTO (REPEAT) FLG FLASHING HWH HOT WATER HEATER BM BEAM DR DOOR FLR FLOOR HT HEIGHT BRG BEARING DHM DETENTION HOLLOW METAL FOC FACE OF CONCRETE ID INSIDE DIAMETER BTM BOTTOM DWG DRAWING FOM FACE OF MASONRY IF INSIDE FACE BUILDING CODE SUMMARY APPLICABLE CODES: INTERNATIONAL & NATIONAL CODES: 2012 INTERNATIONAL BUILDING CODE 2009 ICC / ANSI Al 17.1 2012 INTERNATIONAL MECHANICAL CODE 2012 INTERNATIONAL FIRE CODE 2012 UNIFORM PLUMBING CODE 2012 NATIONAL ELECTRICAL CODE WASHINGTON STATE CODES: 2012 WASHINGTON STATE ENERGY CODE CHAPTER 51-11 WAC WASHINGTON STATE CODES AMENDMENTS: WA STATE AMENDMENTS TO THE 2012 IBC CHAPTER 51-50 WAC WA STATE AMENDMENTS TO THE 2012 IMC CHAPTER 51-52 WAC WA STATE AMENDMENTS TO THE 2012 IFC CHAPTER 51-54 WAC WA STATE AMENDMENTS TO THE 2012 UPC CHAPTER 51-56 AND 51-57 WAC BUILDING CODE NOTES Code Note Placeholder APPROVALS (NAME) (NAME) (NAME) (NAME) permit No, V"amal Flan review approval is subled to errors and omissions. }approval of oonstu ion d=jlrnents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fiel and conditiv is owl d: Bir data:City of of Tula BUILDING DIVISION IN INCH NO NUMBER REQ'D INSUL INSULATION NS NEAR SIDE RHWS INT INTERIOR NTS NOT TO SCALE RM INT INTERIOR OC ON CENTER RO JAN JANITOR OD OUTSIDE DIAMETER SC JST JOIST OF OUTSIDE FACE SCH JT JOINT OFCI OWNER FURNISHED/ SF KIT KITCHEN CONTRACTOR INSTALLED SHT LAT LATERAL OF01 OWNER FURNISHED/ OWNER SHTG LB POUNDS INSTALLED SIM LF LINEAL FEET OH OVERHANG OR OVERHEAD SP L LENGTH/LONG OPNG OPENING SPS LOC LOCATION OPP OPPOSITE SPEC LT LIGHT ORNT ORIENTATE(ION) SQ M.C. METAL CHANNEL PAR PARALLEL SS MR MOISTURE RESISTANT P/C PRECAST CONCRETE SSK MATL MATERIAL PERP PERPENDICULAR STD MAX MAXIMUM PLAM PLASTIC LAMINATE STGR MB MACHINE BOLT PL PLATE OR PROPERTY LINE STL MECH MECHANICAL PSF POUNDS PER SQUARE FOOT STIR MEZZ MEZZANINE PWD PLYWOOD SUSP MFR MANUFACTURER PSI POUNDS PER SQUARE INCH SV MIN MINIMUM PT PRESSURE TREATED SYM MISC MISCELLANEOUS QTY QUANTITY T MR MOISTURE RESISTANT RAD OR R RADIUS T & B MTD MOUNTED REF REFERENCE T & G MTL METAL REFL REFLECTED TB (N) NEW REFR. REFRIGERATOR THK NIC NOT IN CONTRACT REINF REINFORCED TN REQUIRED TOC TOP OF CONCRETE ROUND HEAD WOOD SCREW TOP TOP OF PAVING ROOM TOM TOP OF MASONRY ROUGH OPENING TOJ TOP OF JOIST SOLID CORE TOS TOP OF SHEATHING SCHEDULE TOW TOP OF WALL SQUARE FOOT (FEET) TPD TOILET PAPER DISPENSER SHEET TSCD TOILET SEAT COVER SHEATHING DISPENSER SIMILAR TS TUBE STEEL SPACE(ING) TYP TYPICAL SPACES UBC UNIFORM BUILDING CODE SPECIFICATIONS LION UNLESS OTHERWISE NOTED SQUARE VCT VINYL COMPOSITION TILE STAINLESS STEEL VERT OR V VERTICAL SERVICE SINK VIF VERIFY IN FIELD STANDARD W WIDE (WIDTH) STAGGER W/ WITH STEEL W/o WITHOUT STRUCTURAL WB WHITE BOARD SUSPENDED(TION) WC WATER CLOSET SHEET VINYL WD WOOD SYMMETRICAL WIN WINDOW TOP WP WATER PROOF / WORK POINT TOP AND BOTTOM WWF WELDED WIRE FABRIC TONGUE AND GROOVE YD YARD TACK BOARD THICK TOE NAIL DATE: IH-141114 DATE: DATE: REVISIONS No d nges shall be made to the scope of work vtnthout prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PE'Ri" 11T REQUIRED FOR: I! hmeimanicaf rae� Ras City of Tukwila BU11MING DIVISION /O1 OXP�kG qoo� G PROJECT LOCATION PROJECT NORTH CASECA_DE VIEW ELEMENTARY SCHOOL PLAN SCALE: 1/64" =1'-0" AnrA R A A M CORRECT ION I :FIVE° rUKWILA �xr 7M MAW A. 6EAFM8&FL. SEAM W- WANTON KMB Project # E1314B ORIGINAL SHEET SIZE = 30 x 42 HALF SIZE REDUCTIONS =15 x 21 REVISIONS: DATE: 5-5-15 CONSTRUCTION DOCUMENTS SHEET NO. ti UNDERSIDE OF EXIST PLYWD DECK (+/-13'-0" AFF, FIELD VERIFY) EXISTING GLU-LAM BEAM 20 GA SLOTTED METAL SLIP TRACK WITH MIN. 34' ALLOWABLE DEFLECTION EXISTING DUCTWORK - WHERE IT PENETRATES THE NEW WALL, CLEANLY TRIM OUT/FINISH THE GWB AND SEAL WITH ACOUSTICAL SEALANT EXISTING SPRINKLER OR CONDUIT - WHERE IT PENETRATES THE NEW WALL, CLEANLY TRIM OUT/FINISH THE GWB AND SEAL WITH ACOUSTICAL SEALANT 20 GA MTL STUDS @ 24"O.C., 31/2" UNFACED BATT INSUL, TWO LAYERS 5/8" GWB ONE SIDE & ONE LAYER 5/8" GWB ON THE OTHER SIDE REMOVE/SELECTIVELY DEMO EXIST SUSPENDED ACOUST CLG SYSTEM FOR INSTALL OF NEW WALL - PATCH/ REPAIR SYSTEM BACK TO NEW WALL WITH NEW COMPONENTS TO MATCH EXISTING TOP OF WALL CONNECTION SCALE: 1 1/2" =1'-0" TOP OF WALL CONNECTION SCALE: 1/2" =1'-0" CONSTRUCT N WALL AT EDGE EXISTING RELIT EXISTING DECK - PROVIDE SLIP TRACK AND ALLOW FOR 3/4" DEFLECTION EXISTING CEILING JOIST PENETRATIONS - CLEANLY TRIM OUT/FINISH THE GWB AND SEAL WITH ACOUSTICAL SEALANT - ALLOW FOR 3/4" DEFLECTION EXISTING DUCT PENETRATIONS - CLEANLY TRIM OUT/FINISH THE GWB AND SEAL WITH ACOUSTICAL SEALANT APPROXIMATE LOCATION OF CEILING NEW WALL - EXTEND FROM SLAB ON GRADE FLOOR TO UNERSIDE OF EXISTING STRUCTURE, FRAME AROUND EXISTING OBSTACLES AND PENETRATIONS M/E/P NOTES FOR INTERVENTION ROOM: 1. CONTRACTOR TO PROVIDE NEW, SEPARATE, DESIGN/BL HVAC SYSTEM AND CONTROLS FOR THE NEW INTERVENTI ROOM SPACE. NEW SYSTEM SHALL BE DESIGNED TO MEE ALL APPLICABLE CODES, SHALL BE FULLY FUNCTIONAL k SHALL BE BALANCED/COMMISIONED AS PART OF THE CONTRACT WORK. SHOP/PERMIT DRAWINGS, CALCULATIONS, NREC FORMS AND PERMITTING COSTS. 2. CONTRACTOR TO PROVIDE DESIGN/ BUILD RECONFIGURATION OF THE LIGHTING AND LIGHTING CONTROLS SYSTEM TO SERVE THE NEW INTERVENTION SPACE. NEW SYSTEM SHALL BE DESIGNED TO MEET ALL APPLICABLE CODES, SHALL BE FULLY FUNCTIONAL AND SHALL BE COMMISSIONED AS PART OF THE CONTRACT W( CONTRACT WORK TO INCLUDE ALL ASSOCIATED SHOP/PERMIT DRAWINGS, CALCULATIONS, NREC FORMS / PERMITTING COSTS. 3. CONTRACTOR TO PROVIDE DESIGN/ BUILD RECONFIGURATION OF THE FIRE SPRINKLER SYSTEM TO SERVE THE NEW INTERVENTION SPACE. NEW SYSTEM SHj BE DESIGNED TO MEET ALL APPLICABLE CODES, SHALL BE FULLY FUNCTIONAL AND SHALL BE COMMISSIONED AS PAI OF THE CONTRACT WORK. CONTRACT WORK TO INCLUDE ALL ASSOCIATED SHOP/PERMIT DRAWINGS, CALCULAT0 AND PERMITTING COSTS. 4. CONTRACTOR TO PROVIDE DESIGN/ BUILD RECONFIGURATION OF THE FIRE ALARM SYSTEM TO SERA THE NEW INTERVENTION SPACE. NEW SYSTEM SHALL BE DESIGNED TO MEET ALL APPLICABLE CODES, SHALL BE FL FUNCTIONAL AND SHALL BE BALANCED/COMMISIONED AS PART OF THE CONTRACT WORK. CONTRACT WORK TO INCLUDE ALL ASSOCIATED SHOP/PERMIT DRAWINGS AND PERMITTING COSTS. PARTIAL FLOOR PLAN AT ART ROOM &INTERVENTION SCALE: 1/4" =1'-0" n PARTIAL CEILING PLAN AT ART ROOM & INTERVENTION FES FOR ART ROOM: 4CTOR SHALL MODIFY/ RECONFIGURE EXISTING 3TEM TO SERVE THE RECONFIGURED ART ROOM. SYSTEM SHALL BE DESIGNED TO MEET ALL ILE CODES, SHALL BE FULLY FUNCTIONAL AND BALANCED/COMMISIONED AS PART OF THE 7 WORK. CONTRACT WORK TO INCLUDE, ALL I-ED SHOP/PERMIT DRAWINGS, CALCULATIONS, NREC VD PERMITTING COSTS. ACTOR TO PROVIDE DESIGN/ BUILD 3URATION OF THE LIGHTING AND LIGHTING .S SYSTEM TO SERVE THE RECONFIGURED ART ACE. REVISED SYSTEM SHALL BE DESIGNED TO .APPLICABLE CODES, SHALL BE FULLY FUNCTIONAL -L BE COMMISSIONED AS PART OF THE CONTRACT ONTRACT WORK TO INCLUDE ALL ASSOCIATED RMIT DRAWINGS, CALCULATIONS, NREC FORMS AND NG COSTS. ACTOR TO PROVIDE DESIGN/ BUILD 3URATION OF THE FIRE SPRINKLER SYSTEM TO IE ART ROOM SPACE. NEW SYSTEM SHALL BE ) TO MEET ALL APPLICABLE CODES, SHALL BE FULLY 4AL AND SHALL BE COMMISSIONED AS PART OF THE ;T WORK. CONTRACT WORK TO INCLUDE ALL fED SHOP/PERMIT DRAWINGS, CALCULATIONS AND NG COSTS. ACTOR TO PROVIDE DESIGN/ BUILD 3URATION OF THE FIRE ALARM SYSTEM TO SERVE ROOM SPACE. NEW SYSTEM SHALL BE DESIGNED TO . APPLICABLE CODES, SHALL BE FULLY FUNCTIONAL -L BE COMMISSIONED AS PART OF THE CONTRACT ONTRACT WORK TO INCLUDE ALL ASSOCIATED RMIT DRAWINGS AND PERMITTING COSTS. GENERAL NOTES EXITING THE LARGER ART ROOM WILL BE APPROXIMATELY 1,024 SF WHEN SUBDIVIDED. WITH AN OCCUPANT LOAD FACTOR OF 20 SF/STUDENT, THE OCCUPANT LOAD WILL EXCEED 50 FOR THE SPACE. THEREFORE TWO EXISTS WILL BE REQUIRED, THE EXITS MUST BE SEPARATED BY AT LEAST ONE HALF OF THE DIAGONAL DISTANCE ACROSS THE ROOM AND THE DOORS SHALL SWING IN THE DIRECTION OF EGRESS. THE DIAGONAL DISTANCE ACROSS THE RESULTANT ROOM IS 57'-411. THE EXISTING EXIT DOORS ARE 31'-8" APART AND THE SWING OUTWARD IN THE DIRECTION OF EGRESS. THE SMALLER INTERVENTION ROOM WILL BE ABOUT 407 SF. WITH AN OCCUPANT LOAD FACTOR OF 20 SF/STUDENT, THE OCCUPANT LOAD WILL NOT EXCEED 50 FOR THE SPACE. THEREFORE ONLY ONE EXIT WILL BE REQUIRED AND IT DOES NOT HAVE TO SWING IN THE DIRECTION OF EGRESS. THIS NEW INTERVENTION ROOM WILL EXIT THROUGH THE LARGER ART ROOM, DIRECTLY TO THE CORRIDOR SYSTEM. IT IS ACCEPTABLE, PER CODE, TO EXIT THROUGH ONE INTERVENING SPACE ENROUTE TO THE BUILDINGS CORRIDOR SYSTEM. WALL CONSTRUCTION WALLS ARE TO BE FULL HEIGHT (FLOOR TO UNDERSIDE OF STRUCTURE), BE CONSTRUCTED OF 20GA METAL STUDS, SPACED 24"O.C. WITH ONE LAYER OF 5/8" GWB ON ONE SIDE, 3112" BATT INSULATION IN THE STUD CAVITIES AND TWO LAYERS OF 5/8" GWB ON THE OPPOSITE SIDE OF THE WALL. PROVIDE ACOUSTICAL SEALANT WHERE THE NEW WALL MEETS EXISTING FLOOR, WALL AND CEILING SURFACES. PROVIDE SLIP TRACK TO ALLOW MINIMUM OF 3l4" OF DEFLECTION AT THE TOP OF WALLS WHERE THEY MEET ROOF STRUCTURE/ROOF DECK. PENETRATIONS OF CONDUITS OR DUCTS THROUGH NEW WALLS SHALL BE CLEANLY TRIMMED OUT BY THE GWB AND SEALED WITH ACOUSTICAL SEALANT. TAPE/TEXTURE WALLS TO A LIGHT ORANGE PEEL FINISH, PRIME WALL AND PAINT WITH 2 COATS OF LATEX PAINT TO MATCH EXISTING ADJACENT. CEILING CONSTRUCTION CONSTRUCTION OF THE NEW FULL -HEIGHT WALLS WILL REQUIRE SELECTIVE DEMOLITION OF THE EXISTING SUSPENDED ACOUSTICAL CEILING SYSTEM, LIGHTS AND HVAC DIFFUSERS/GRILLES ALONG THE ROUTE OF THE NEW WALLS. UPON COMPLETION OF THE WALLS, CONTRACTOR SHALL PATCH/REPAIR THE EXISTING GRID AND TILES WITH NEW SYSTEM COMPONENTS AS REQUIRED TO EXTEND TO AND TERMINATE AT THE NEW WALL. NEW GRID AND TILES SHALL MATCH THE EXISTING IN COLOR, TEXTURE AND APPEARANCE. AT CONTRACTORS OPTION, THE SUSPENDED CEILING THROUGHOUT BOTH ROOMS MAY BE DEMOLISHED AND REPLACED, IN ITS ENTIRETY, WITH NEW SUSPENDED CEILING SYSTEM TO MATCH EXISTING. NEW SUSPENDED ACOUSTICAL CEILING SYSTEM SHALL BE INSTALLED TO COMPLY WITH SEISMIC DESIGN CRITERIA AS RECOMMENDED IN THE LATEST VERSION OF THE NORTHWEST WALL & CEILING BUREAU DOCUMENT 401. FLOOR TILES IT IS THE DESIGN INTENT THAT THE NEW WALL PLATES GET SHOT DOWN DIRECTLY TO THE EXISTING CONCRETE FLOOR SLAB AND THAT THE EXISTING FLOOR TILES WOULD REMAIN. IT IS UNCLEAR WHETHER THE EXISTING FLOOR TILES AND/OR THE FLOORING ADHESIVE IS ASBESTOS BEARING MATERIAL. CONTRACTOR TO CONFIRM WITH THE DISTRICT IF EXISTING TILE FLOORING AND/OR FLOOR ADHESIVE CONTAIN ASBESTOS FIBERS BY EITHER PAST DOCUMENTED EVIDENCE (AHERA REPORTS) OR ADDITIONAL SPECIAL TESTING. PROVIDE NEW FLOORING AND RUBBER BASE TO MATCH EXISTING ADJACENT WHERE THE CASEWORK IS REMOVED FROM THE NORTH WALL OF THE INTERVENTION ROOM. DOOR AT THE NEW INTERVENTION ROOM, PROVIDE A NEW 16 GA HOLLOW METAL DOOR FRAME, 3'-0" X T-0" SOLID CORE DOOR WITH HARDWOOD VENEER AND A 4"Wx24"H TEMPERED GLASS DOOR LITE, A CLASSROOM MORTISED LOCK, CLOSER, HINGES, SEALS AND KICK PLATE. DOOR PACKAGE SHALL MATCH THE EXISTING ADJACENT CLASSROOM DOOR. KEY TO DISTRICT STANDARD. CASEWORK REMOVE/SALVAGE THE EXISTING TALL CABINETS, BASE CABINETS AND UPPER CABINETS OFF OF THE NORTH WALL OF WHAT WILL BE THE INTERVENTION ROOM. DISPOSE OF EXISTING COUNTERTOP. INSTALL SALVAGED CABINETS ON NORTH WALL OF THE RECONFIGURED ART ROOM. SCRIBE TO WALLS AND PROVIDE NEW PLAM CLOSURE PANELS AS REQUIRED. PROVIDE NEW PLAM COUNTERTOP AND BACKSPLASH AT BASE CABINETS. PROVIDE NEW RUBBER BASE TO MATCH EXISTING ADJACENT. AT WALL OF INTERVENTION ROOM, WHERE CABINETS WERE REMOVED, PATCH/REPAIR WALL SURFACE TO MATCH EXISTING ADJACENT, PRIME AND PAINT WITH TWO COATS OF LATEX PAINT TO MATCH EXISTING. INSTALL RUBBER BASE TO MATCH EXISTING. MECHANICAL RELOCATE EXISTING DIFFUSERS/GRILLES TO THE EXISTING ART ROOM SIDE OF THE NEW WALL. PROVIDE A NEW HVAC SYSTEM AND CONTROLS FOR THE NEW INTERVENTION ROOM. INCLUDE ALL LABOR AND MATERIALS FOR A FULLY FUNCTIONING SYSTEM. REBALANCE/BALANCE BOTH THE EXISTING AND NEW HVAC SYSTEMS AT THESE ROOMS. ADJUST/EXPAND THE FIRE SPRINKLER SYSTEM AS REQUIRED TO MEET CODE WITH THE NEW CONFIGURATION. ELECTRICAL PROVIDE TWO (2) NEW DUPLEX OUTLETS AT EACH RUN OF THE NEW WALLS. (FOUR (4) OUTLETS TOTAL.) REWORK EXISTING LIGHT FIXTURES AND SWITCHING TO DIVIDE/SEPARATE LIGHTS BETWEEN THE TWO SPACES. RELOCATE LIGHTS AT BOTH ROOMS AS SHOWN IN THE DRAWINGS. PROVIDE A NEW SWITCH AT THE INTERVENTION ROOM DOOR AND REWIRE THE LIGHT IN THE INTERVENTION ROOM TO THAT SWITCH. ADD TWO NEW DATA OUTLETS AND PATHWAYS AT THE INTERVENTION ROOM. PROVIDE ADDITIONAL FIRE ALARM DEVICES AS REQUIRED TO MEET CODE. EQUIPMENT ON THE EAST SIDE OF THE NEW WALL, FACING THE ART ROOM, INSTALL A NEW 14'Wx6'H TACKBOARD. ON THE OPPOSITE SIDE OF THE SAME WALL, INSTALL A NEW 8'Wx4'H WHITEBOARD WITH PEN TRAY. LEGEND EXISTING SPRINKLER HEAD TO REMAIN O NEW SPRINKLER HEAD LOCATION EXISTING SUPPLY AIR GRILLE TO REMAIN NEW LOCATION OF RELOCATED SUPPLY AIR GRILLE EXISTING LIGHT FIXTURE TO REMAIN EXISTING LIGHT FIXTURE TO BE RELOCATED L� --R)J NEW LOCATION OF RELOCATED LIGHT FIXTURE PROJECT NORTH REVEWED FOR CODECOMPLIANCE APPROVED OCT 14 2015 Ciiy of Tukwila BUILDING DIVISION SCOPE OF WURK RECEIVED CITY OF TUKWI+ A OCT 0.2 2015 PERMIT CENTER - e�1110'.-1111-121 Ill N. design groups, inc. p.s. architecture education facilities group justice facilities group security design group 828-7th Avenue SE Olympia, WA 98501 360.352.8883 KMB Project# E1314B ORIGINAL SHEET SIZE = 30 x 42 HALF SIZE REDUCTIONS =15 x 21 REVISIONS: DATE: 5-5-15 CONSTRUCTION DOCUMENTS SHEET NO. SCALE: 1/4" =1'-0" KEYPLAN SCALE:.1/128" =1'-0"