Loading...
HomeMy WebLinkAboutPermit D15-0255 - ENTERPRISE INSTALLATION - GARAGE DOORENTERPRISE INSTALI.AT'ION INC 4457 S 134 PL D15-0255 .R City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 2613200084 Permit Number: D15-0255 Address: 4457 S 134TH PL BLDG C Issue Date: 11/10/2015 Permit Expires On: 5/8/2016 Project Name: ENTERPRISE INSTALLATION INC Owner: Name: REALTY ASSOCIATES FUND X LP Address: 1301 DOVE ST#860, NEWPORT BEACH, WA, 92660 Contact Person: Name: STEPHEN SNEE Address: 4459 S 134 PL, TUKWILA, WA, 98168 Contractor: Name: CRESSY DOOR CO INC Address: PO BOX 55549, SHORELINE, WA, 98155 License No: CRESSDC370NT Lender: Name: SELF FUNDED - STEPHEN SNEE Phone: (206) 730-6648 Phone: (206) 632-0533 Expiration Date: 11/25/2016 Address: , , , DESCRIPTION OF WORK: CHANGE EXISTING GARAGE DOOR FROM 9' X 9' TO 14' X 10'. CUT OUT 5 FT OF CONCRETE PANELING ABOVE EXISTING OPENING, CUT OUT 1 FT TO THE SIDE OF THE OPENING. REINFORCE WITH STEEL CHANNEL Project Valuation: $8,250.00 Fees Collected: $457.90 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: Occupancy per IBC: Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: 125 Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Chan neIization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature:I 1�l�lw Date: I �� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this per does not presume to give authority to violate or cancel the provisions of any other state or local laws reg ating,5c9 struc or the performance of work. I am authorized to sign and obtain this development permi n ag e to th nditions tached to this permit. Signature: Dat el/— Print Name:i`i"- This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 4046 SI-EPDXY/EXP CONC CITY OF TM, .L A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hitp://www.TukwilaWA.jzov Building Permit No. —0; �_7S Project No. Date Application Accepted: '7nn -'10-1 S_ -1S_ Date Application Expires: 0 use CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION A/A/' .,/ S 1,3 King Co Assessor's Tax No.: Site Address: y �4. %2ts�fCo� Suite Number: Floor: Tenant Name:�`�f�✓ ��✓ New Tenant: ❑ .....Yes No PROPERTY OWNER Name: Address: Ar S City: (�`r�C� State: W/4 Zip: %Gl�a�1 CONTACT PERSON — person receiving all project communication Name S� 16 Address. �` l�9 X / Sy City: .1Wz.e,1L1q- Stater Zip:lof Phone:2,>6 .3c, �6Zg Fax:_1114, W 0 Email: 0^177f, pMJC INJTX t.0 A4 GENERAL CONTRACTOR INFORMATION Company Name: Ess t?t)2 Address: -z �T City: �firj_ State: w,4 Zip: 0�03 Phone: Z5-� A _ ,1 F x: Z513 ! O Contr Reg No.: X 7-3 F 01 C P, r Exp Date: 96 Tukwila Business License No.: ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Engineer Name: Address: /80 �i��G�✓ :S'� �//r City: <�% T2� State A ' Zip: 5;1 Phone: Zc>6 /Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: It XSY ii City: A v4e, State: A), Zip: 8oz/ i nm H:Wpplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page 1 of 4 BUILDING PERMIT INFORMATI( . 206-431-3670 Valuation of Project (contractor's bid price): $ 8Z66- s Existing Building Valuation: $ Describe the scope of work (please provide detailed information): � r ovf 5r 6� C�/✓L� %-�-i.,.� /��'y✓� �act.�7��G G��i/i�c/�, !/ /1J ! &,�O /V fr (.y i/�% .. �F IV �L CC- A)1 / � Will there be new rack storage? ❑ .... Yes [9/No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor 2 nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....... Yes ❑ .......No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ...... Sprinklers ❑ .......Automatic Fire Alarm El ....... None ❑....... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .......Yes ❑ ...... No If "yes, attach list of materials and storage locations on a separate 8-112" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:IApplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page 2 of 4 WORKS PERMIT INFC .ATION — 206-433-0179 Scope of Work (please provide detailed information): LAzAn.6E" iX '� 67'w�'�5- V"o /Ge�l'v�C 4J17W ,f'.rps'(_ Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. W r District 9.. Tukwila ❑ ... Water District # 125 ❑ ... Highline ❑. Renton ❑ .. Water Availability Provided Sewer District . Tukwila ❑ ...Valley View El ... Renton ❑... Seattle ❑ .. Sewer Use Certificate ❑ ...Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apr ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) El ... Geotechnical Report El.. Traffic Impact Analysis ❑ .. Bond ❑... Insurance ❑... Easement(s) El ... Maintenance Agreement(s) El.. Hold Harmless — (SAO) .. Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑... Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑... Right-of-way Use — Potential Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ .. Total Cut cubic yards ❑ .. Total Fill cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water El ... Work in Flood Zone El ... Storm Drainage El ... Abandon Septic Tank El ... Curb Cut El ... Pavement Cut El ... Looped Fire Line ❑ .. Permanent Water Meter Size (1) WO # (2) ❑ .. Temporary Water Meter Size (1) WO # (2) ❑ .. Water Only Meter Size........... WO # ❑ .. Sewer Main Extension............ Public ❑ Private ❑ ❑ .. Water Main Extension............ Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line _ ❑ .. Water ❑ .. Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billinc: Mailing ❑... Grease Interceptor ❑... Channelization ❑ ... Trench Excavation El ... Utility Undergrounding WO # (3) " WO # WO # (3) WO # El.. Deduct Water Meter Size " Number of Public Fire Hydrant(s) ❑ .. Sewage Treatment Day Telephone: City Day Telephone: State Zip City State Zip H:\Applications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJYRY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Date: Print Name: `� � � /� Jam✓ �1 � Day Telephone: �b 7-3O Mailing Address: -�7 Yv IS, 13�1 "14 �C✓( g City State Zip H:Wpplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page 4 of 4 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $457.90 D15-0255 Address: 4457 S 134TH PL BLDG C Apn: 2613200084 $457.90 DEVELOPMENT $444.56 PERMIT FEE R000.322.100.00.00 0.00 $266.70 PLAN CHECK FEE R000.345.830.00.00 0.00 $173.36 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $13.34 TECHNOLOGY FEE TOTAL'. •. R000.322.900.04.00 0.00 $13.34 $457.90 Date Paid: Wednesday, September 30, 2015 Paid By: STEPHEN SNEE SR Pay Method: CREDIT CARD 05824G Printed: Wednesday, September 30, 2015 1:16 1 of 1 CR?w SY57EM5 PM INSPECTION RECORD Retain a copy with permit ✓/� I CTION NO. PERM NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 4 Pro"ect: -� " T of Insp tion:I r Z laz!!5 Date Called: pe ial Instructions: Date Wanted: / a.m .m. Requester: Phone No: ppraved per applicable codes. Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RE Retain a copy with IN CTION NO. permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 SOuthcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Proj - jam' Is n` .> Type of I spe do Address: `y� � Date Called: Special Instructions: Date Wanted: L1,6 P.M. Requester: Phone No: proved per applicable codes. L]Corrections required prior to approval. u paid at 6300 Southcenter Blvd.. Suite 100. Cali to schedule reinspection. - 180 Nickerson St. INC. Suite 302 Seattle, WA 98109 (206)285-4512(V) (206) 285-0618(F) AIL STRUCTURAL CALCULATIONS Expand Door Opening in Existing Tilt Up Building Enterprise Installation Fostoria Park Building C 4457 S 134' Place Tukwila, WA REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 6 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 3 0 201.5 PERMIT CENTER V Structural Engineers �7 180 Nickerson St. �C TE N G I N E E R I N G Suite 302 i N C. Seattle, WA Project; Piz � 5, //VS7 �/f r`7o�✓ gate: �// �' 1/ 201 S' 98109 (zo o 285•4512 rnx: Client: Page Number: (206) 285.0618 / T" /NGIt, ve- ro-noj e�g-6 7 S . r 3 91N o0G w 6-0-Y&P014d i ram ✓fug 5e-om6 Structural Engineers Project: �1"I%&t01 - �S Client: •ey emAtl oven #4"j/ ogtmon i or- eq w-9-CO,1ve, 180 Nickerson St. Suite 302 J O Seattle, WA 98109 Date: ( 6 (206) 285-4512 PAX: Page Number: (206) 285.0618 G�X 3• S' w/ sly" T)mw i �.s L ~ 0 (��r 2,� (1 s0 idly) 4C, 3 3'� I z 3 ►R: hJINY> !$ P5P- ( I Z, f-►, ) 2 C b j Po-i . Structural Engineers Title,Block Line 1 Project Title: You can change this area Engineer: Project ID: using the "Settings" menu item Project Descr: and then using the "Printing & Title Block" selection. Title Block Line 6 Pdnted: 15 SEP 2015. 8:31AM Steel Beam File = R:It52xx Enterprise InstallationslENGRIExpress.eo6 ENERCALC, INC.1983.2015, Build:6.15.7.8, Ver:6.15.7.8 r,rr Description : beam at top of opening CODE REFERENCES Calculations per AISC 360-10, IBC 2012, ASCE 7-10 Load Combination Set: ASCE 7-10 Material Properties Analysis Method: Allowable Strength Design Beam Bracing : Completely Unbraced Bending Axis: Major Axis Bending Load Combination ASCE 7-10 D 0.804 S 0.3 I Span = 10.0 ft M13.75 Fy : Steel Yield : 50.0 ksi E: Modulus: 29,000.0 ksi Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.8040, S = 0.30 k/ft, Tributary Width =1.0 ft DESIGN SUMMARY ' • Maximum Bending Stress Ratio = _ 0.931 : 1 Maximum Shear Stress Ratio = 0.128 : 1 iSection used for this span C8x13.75 Section used for this span C8x13.75 Ma : Applied 13.972 k-ft Va : Applied 5.589 k Mn / Omega: Allowable 15.011 k-ft Vn/Omega : Allowable 43.545 k Load Combination +D+S+H Load Combination +D+S+H Location of maximum on span 5.000ft Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.065 in Ratio = 1,846 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.in Ratio = 49 Max Upward Total Deflection 0.000000 in Ratio = 0 0 <240 ' - -- -- - ` Maximum Forces & Stresses for Load Combinations - Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega +D+H Dsgn. L = 10.00 ft 1 0.681 0.094 10.22 10.22 25.07 15.01 1.14 1.00 4.09 72.72 43.54 +D+L+H Dsgn. L = 10.00 ft 1 0.681 0.094 10.22 10.22 25.07 15.01 1.14 1.00 4.09 72.72 43.54 +D+Lr+H Dsgn. L = 10.00 ft 1 0.681 0.094 10.22 10.22 25.07 15.01 1.14 1.00 4.09 72.72 43.54 +D+S+H Dsgn. L = 10.00 ft 1 0.931 0.128 13.97 13.97 25.07 15.01 1.14 1.00 5.59 72.72 43.54 +D+0.750Lr+0.750L+H Dsgn. L = 10.00 ft 1 0.681 0.094 10.22 10.22 25.07 15.01 1.14 1.00 4.09 72.72 43.54 +D+0.750L+0.750S+H Dsgn. L = 10.00 ft 1 0.868 0.120 13.03 13.03 25.07 15.01 1.14 1.00 5.21 72.72 43.54 +D+0.60W+H Dsgn. L = 10.00 ft 1 0.681 0.094 10.22 10.22 25.07 15.01 1.14 1.00 4.09 72.72 43.54 +D+0.70E+H Dsgn. L = 10.00 ft 1 0.681 0.094 10.22 10.22 25.07 15.01 1.14 1.00 4.09 72.72 43.54 +D+0.750Lr+0.750L+0.450W+H Dsgn. L = 10.00 ft 1 0.681 0.094 10.22 10.22 25.07 15.01 1.14 1.00 4.09 72.72 43.54 +D+0.750L+0.750S+0.450W+H Dsgn. L = 10.00 ft 1 0.868 0.120 13.03 13.03 25.07 15.01 1.14 1.00 5.21 72.72 43.54 +D+0.750L+0.750S+0.5250E+H Dsgn. L = 10.00 ft 1 0.868 0.120 13.03 13.03 25.07 15.01 1.14 1.00 5.21 72.72 43.54 +0.60D+0.60W+0.60H Dsgn. L = 10.00 ft 1 0.409 0.056 6.13 6.13 25.07 15.01 1.14 1.00 2.45 72.72 43.54 Title Block Line 1 Project Title: You can change this area Engineer: Project ID: using the "Settings" menu item Project Descr: and then using the "Printing & Title Block" selection. Title Block Line 6 Printed:15 SEP 2015, 8:31AM Steel Beam File=R:1152xxEnterprise lnstallationslENGRIExpress.ec6 ENERCALC, INC.1983.2015, Build:6.15.7.8, Ver.6.15.7.8 •• IMIN�.rr Description : beam at top of opening Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V Mmax + Mmax - Ma - Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega +0.60D+0.70E+0.60H Dsgn. L = 10.00 ft 1 0.409 0.056 6.13 6.13 25.07 15.01 1.14 1.00 2.45 72.72 43.54 Overall Maximum Deflections Load Combination Span Max. "" Defl _ Location in Span Load Combination Max. "+" Defl Location in Span +D+S+H 1 0.2421 5.050 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 5.589 5.589 Overall MINimum 1.500 1.500 +D+H 4.089 4.089 +D+L+H 4.089 4.089 +D+Lr+H 4.089 4.089 +D+S+H 5.589 5.589 +D+0.750Lr+0.750L+H 4.089 4.089 +D+0.750L+0.750S+H 5.214 5.214 +D+0.60W+H 4.089 4.089 +D+0.70E+H 4.089 4.089 +D+0.750Lr+0.750L+0.450W+H 4.089 4.089 +D+0.750L+0.750S+0.450W+H 5.214 5.214 +D+0.750L+0.750S+0.5250E+H 5.214 5.214 +0.60D+0.60W+0.60H 2.453 2.453 +0.60D+0.70E+0.60H 2,453 2.453 D Only 4.089 4.089 Lr Only L Only S Only 1.500 1.500 W Only E Only H Only Title Block Line 1 Project Title: You can change this area Engineer: Project ID: using the "Settings" menu item Project Descr: and then using the "Printing & Title Block" selection. Title Block Line 6 Printed:15 SEP 2015, 2:29PM Steel Column File = R:1152xx Enterprise InstallationsTNGRIExpress.ec6 ENERCALC, INC.1983-2015, Build:6.15.7.8, Ver.6.15.7.8 Description : strongback Code References Calculations per AISC 360-10, IBC 2012, CBC 2013, ASCE 7-10 Load Combinations Used : ASCE 7-10 General Information Steel Section Name Analysis Method : Steel Stress Grade Fy : Steel Yield E : Elastic Bending Modulus Load Combination : HSS5x2-1/2x1/4 Overall Column Height 22.0 ft Allowable Strength Top & Bottom Fixity Top & Bottom Pinned Brace condition for deflection (buckling) along columns 42.0 ksi X-X (width) axis: 29,000.0 ksi Fully braced against buckling along X-X Axis ASCE 7-10 Y-Y (depth) axis: Fully braced against buckling along Y-Y Axis Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weight included : 249.262 Ibs' Dead Load Factor BENDING LOADS ... Lat. Uniform Load creating Mx-x, W = 0.110 k/ft Lat. Uniform Load from 0.0-->14.0 ft creating Mx-x, E = 0.0250 k/ft Lat. Uniform Load from 12.0-->22.0 ft creating Mx-x, E = 0.1250 k/ft DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio = 0.3960 : 1 Maximum SERVICE Load Reactions . . Load Combination +D+0.60W+H Top along X-X 0.0 k Location of max.above base 10.926 ft Bottom along X-X 0.0 k At maximum location values are ... Top along Y-Y 1.210 k Pa: Axial 0.2493 k Bottom along Y-Y 1.210 k Pn / Omega: Allowable 78.970 k Ma-x : Applied 3.993 k-ft Maximum SERVICE Load Deflections ... Mn-x / Omega : Allowable 10.123 k-ft Along Y-Y 2.150 in at 11.074 ft above base for load combination: W Only Ma-y :Applied 0.0 k-ft Mn-y / Omega: Allowable 6.183 k-ft Along X-X 0.0 in at 0.0ft above base for load combination PASS Maximum Shear Stress Ratio = 0.02493 : 1 Load Combination +D+0.70E+H Location of max.above base 22.0 ft At maximum location values are ... Va : Applied 0.7541 k Vn / Omega: Allowable 30.244 k Load Combination Results Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination Stress Ratio Status Location Stress Ratio Status Location +D+H 0.003 PASS 0.00 ft 0.000 PASS 0.00 ft +D+L+H 0.003 PASS 0.00 ft 0.000 PASS 0.00 ft +D+Lr+H 0.003 PASS 0.00 ft 0.000 PASS 0.00 ft +D+S+H 0.003 PASS 0.00 ft 0.000 PASS 0.00 ft +D+0.750Lr+0.750L+H 0.003 PASS 0.00 ft 0.000 PASS 0.00 ft +D+0.750L+0.750S+H 0.003 PASS 0.00 ft 0.000 PASS 0.00 ft +D+0.60W+H 0.396 PASS 10.93 ft 0.024 PASS 0.00 ft +D+0.70E+H 0.322 PASS 13.44 ft 0.025 PASS 22.00 ft +D+0.750Lr+0.750L+0.450W+H 0.297 PASS 10.93 ft 0.018 PASS 0.00 ft +D+0.750L+0.750S+0.450W+H 0,297 PASS 10.93 ft 0.018 PASS 0.00 ft +D+0.750L+0.750S+0.5250E+H 0.242 PASS 13.44 ft 0.019 PASS 22.00 ft +0.60D+0.60W+0.60H 0.395 PASS 10.93 ft 0.024 PASS 0.00 ft +0.60D+0.70E+0.60H 0.322 PASS 13.44 ft 0.025 PASS 22.00 ft Title,Block Line 1 Project Title: You can change this area Engineer: Project ID: using the "Settings" menu item Protect Descr: and then using the "Printing & Title Block" selection. Title Block Line 6 Printed: 15 SEP 2015, 2:29PM Stee I Column File = R:1152xx Enterprise Installatlons\ENGRIExpress.ec6 ENERCALC, INC.1902015, Build:6.15.7.8, Ver:6.15.7.8 r.rr Description : strongback Maximum Reactions Note: Only non -zero reactions are listed. X-X Axis Reaction Y-Y Axis Reaction Axial Reaction Load Combination @ Base @ Top @ Base @ Top @ Base +D+H k k 0.249 k +D+L+H k k 0.249 k +D+Lr+H k k 0.249 k +D+S+H k k 0.249 k +D+0.750Lr+0.750L+H k k 0.249 k +D+0.750L+0.750S+H k k 0.249 k +D+0.60W+H k -0.726 0.726 k 0.249 k +D+0.70E+H k -0.366 0.754 k 0.249 k +D+0.750Lr+0.750L+0.450W+H k -0.545 0.544 k 0.249 k +D+0.750L+0.750S+0.450W+H k -0,545 0.544 k 0.249 k +D+0.750L+0.750S+0.5250E+H k -0.274 0.566 k 0.249 k +0.60D+0.60W+0.60H k -0.726 0.726 k 0.150 k +0.60D+0.70E+0.60H k -0.366 0.754 k 0.150 k D Only k k 0.249 k Lr Only k k k L Only k k k S Only k k k W Only k -1.210 1.210 k k E Only k -0.523 1.077 k k H Only k k k Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance +D+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+L+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+Lr+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+S+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.750Lr+0.750L+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.750L+0.750S+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.60W+H 0.0000 in 0.000 ft 1.290 in 11.074 ft +D+0.70E+H 0.0000 in 0.000 ft 0.977 in 11.664 ft +D+0.750Lr+0.750L+0.450W+H 0.0000 in 0.000 ft 0.967 in 11.074 ft +D+0.750L+0.750S+0.450W+H 0.0000 in 0.000 ft 0.967 in 11.074 ft +D+0.750L+0.750S+0.5250E+H 0.0000 in 0.000 ft 0.733 in 11.664 It +0.60D+0.60W+0.60H 0.0000 in 0.000 ft 1.290 in 11.074 ft +0.60D+0.70E+0.60H 0.0000 in 0.000 ft 0.977 in 11.664 It D Only 0.0000 in 0.000 ft 0.000 in 0.000 ft Lr Only 0.0000 in 0.000 ft 0.000 in 0.000 ft L Only 0.0000 in 0.000 ft 0.000 in 0.000 ft S Only 0.0000 in 0.000 ft 0.000 in 0.000 ft W Only 0.0000 in 0.000 It 2.150 in 11.074 ft E Only 0.0000 in 0.000 ft 1.396 in 11.664 ft H Only 0.0000 in 0.000 ft 0.000 in 0.000 ft Steel Section Properties : HSS5x2-112x114 Title, Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Steel Column Description : strongback Steel Section Properties : HSS5x2-112x114 Depth = 5.000 in I xx S xx Width = 2.500 in R xx Wall Thick = 0.250 in Zx Area = 3.140 in12 Iyy Weight = 11.330 plf S yy R yy Zy Ycg = 0.000 in o o -- x Y 2.50in Project Title: Engineer: Project ID: Project Descr: Printed:15 SEP 2015, 229PM File = R:1152xx Enterprise InstallationsIENGR1Express.e06 ENERCALC, INC.1983-2015, Build:6.15.7.8, Ver:6.15.7.8 = 9.40 in^4 J = 7.930inA4 = 3.76 inA3 Cw = 4.99 inA6 1.730 in = 4.830 inA3 = 3.130 in"4 C = 4.990 inA3 = 2.500 in^3 0.999 in = 2.950 inA3 M-x Loads i i i i N' b.t]klf Ni II —� .I —y L� N _' I �I I i Iae n'nmliu '�_.� Loads are total entered value. Arrows do not reflect absolute direction. PERMIT COOK® COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0255 DATE: 09/30/15 PROJECT NAME: ENTERPRISE INSTALLATION INC SITE ADDRESS: 4457 S 134 PL X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: A-T Building Division Public Wo IA PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Revision # before Permit Issued Revision # after Permit Issued MA �k III Fire Prevention Structural ❑ VL- A11A 10-1-1s Planning Division a Permit Coordinator DATE: 10/01/15 Structural Review Required ❑ f97:v4Iis DUE DATE: 10/29/15 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 CRESSY DOOR CO INC Page 1 of 2 OnWashington State Department of Labor & Industries CRESSY DOOR CO INC Owner or tradesperson Principals WITTERS, RICHARD W FERRER, R GEORGE Doing business as CRESSY DOOR CO INC WA UBI No. 578 049 740 License Home lnicio en Espanol Contact Search L&I L A Index Help My Secure L,&I Safety Claims & Insurance Workplace Rights Trades & Licensing PO BOX 55549 SHORELINE, WA 98155 206-632-0533 KING County Business type Corporation Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .................................................. _............ Meets current requirements. License specialties GENERAL License no. CRESSDC370NT Effective — expiration 08/30/1963-11/2512016 Bond ..............._ OLD REPUBLIC SURETY CO $12,000.00 Bond account no. YLI244969 Received by L&I Effective date 11/21/2007 01/01/2003 Expiration date Until Canceled Insurance ......... _ ................. American Fire & Casualty Co $1,000,000.00 Policy no. BKA56806656 Received by L&I Effective date 09/11/2015 09/12/2016 Expiration date 09/1212016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. htti)s:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=578049740&LIC=CRESSDC37ONT&SAW= 11/10/2015 __.�.�✓ I VI\ CODE COMPLIANCE pj hanicat E6�:ricai 9 Plumbing P Gus Piping at of T0,,wila PIVISION NEW C8x13.7 NEW SIMPSON TITEN—HD AT 24"OC EMBEDMENT 4' 0 N NEW OPENING SCALE: 3/4' = 1'-0" TYPICAL CHANNEL SCALE:1"=60' 1� AT TOP OF OPENING 2� REVISIONS the scope 4 F rric, approvt 1 of 10 11j"ding Qivision1 rco p':!n submittal adifionei F �:n 1,01;ew fcss. l INC. Structural Engineers 180 Nickerson Street Suite 302 Seattle, NA 98109 206.285.4512 (V) 206.285.0618 (F) NSTALLATIONS ZK BUILDING 'C" i PL 98168 AREA OF WORK. TER BUILDING PLAN GOOSIC ea&E feet SCALE: NONE Permit No. nk - lld_�� F�lIan review approval is subject to errors an+��TE"iePtAN 9pproval of construad.. 'documents does not authorize the violation of anyd r ordinance. Receipt of approved Field itions is acknowledged: City of 'is� BUILDING I IkNt� �. PROJECT NAME Enterprise Installation —Fostoria Park Bldg. "C" 4459 S 134th PI Tukwila, WA 98168 DATE 09/24/15 Id PROJECT NO. SCALE PAGE: NOV 0 6 2015 iT City of Tukwila m2000 '600 RECEIVED? CITY OF TUKWIL/ SEP 3 0 2015 CENTER 15241 AS NOTED S1.0 STRUCTURAL NOTES 01000. GENERAL REQUIREMENTS THE STRUCTURAL NOTES SUPPLEMENT THE PLANS AND SPECIFICATIONS. ANY DISCREPANCY FOUND BETWEEN THE DRAWINGS, NOTES, SPECIFICATIONS, SITE CONDITIONS, AND ARCHITECTURAL PLANS SHALL BE REPORTED TO THE ARCHITECT WHO SHALL CORRECT THE DISCREPANCY IN WRITING. ANY WORK COMPLETED AFTER DISCOVERY OF THE DISCREPANCY SHALL BE DONE AT THE CONTRACTOR'S RISK. REFER TO ARCHITECTURAL PLANS FOR OPENINGS, ARCHITECTURAL TREATMENTS, AND DIMENSIONS NOT SHOWN. CONSULT MECHANICAL PLANS FOR DUCTS AND PIPES ETC. NOT SHOWN. THE CONTRACTOR SHALL PROVIDE BRACING AND SUPPORT REQUIRED FOR TEMPORARY CONSTRUCTION LOADS AND FOR STRUCTURAL COMPONENTS AS REQUIRED DURING ERECTION. BACKFILL BEHIND WALLS SHALL NOT BE PLACED UNTIL THE WALLS ARE PROPERLY SUPPORTED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE EXCAVATION, SHORING, AND OTHER WORK WITH ALL UTILITIES AND ADJACENT PROPERTIES. CALL THE UTILITY LOCATE SERVICE PRIOR TO ANY WORK AT 1-800-424-5555. 011M. CODE REQUIREMENTS ALL DESIGN AND CONSTRUCTION SHALL CONFORM TO THE 2012 INTERNATIONAL BUILDING CODE AS ADOPTED BY THE CITY OF TUKWILA, WASHINGTON. 01200: DESIGN LOADS ROOF LIVE LOADS ROOF (SNOW) 25 PSF SNOW LOAD DESIGN DATA: Pg = 25 PSF, Pf= 16 PSF, Ce = 0.9, Is = 1.0, Ct = 1.0, WIND DESIGN DATA: BASIC WIND SPEED: WIND IMPORTANCE FACTOR: WIND EXPOSURE: TOPOGRAPHIC FACTOR INTERNAL PRESSURE COEFFICIENT. COMPONENT/CLADDING WIND PRESSURE: EARTHQUAKE DESIGN DATA: SEISMIC IMPORTANCE FACTOR: RICK CATEGORY: SPECTRAL RESPONSE ACCELERATIONS: SITE CLASS: SPECTRAL RESPONSE COEFFICIENTS SEISMIC DESIGN CATEGORY: BASIC FORCE RESISTING SYSTEM: WOOD LEVELS ANALYSIS PROCEDURE: i t 110 MPH (LRFD) (3-SECOND GUST) 1W = 1.0 EXPOSURE B KT = 1.00 GCPI = +/- 0.18 05120: STRUCTURAL STEEL DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION "AISC SPECIFICATION FOR DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". MATERIALS SHALL BE IN ACCORDANCE WITH THE FOLLOWING: STRUCTURAL W SHAPES S, M, AND C SHAPES STEEL ANGLES PLATE MATERIAL STRUCTURAL PIPE STRUCTURAL TUBE HEADED STUDS WELDING ELECTRODES HIGH STRENGTH BOLTS ANCHOR BOLTS WOOD CONNECTION BOLTS ASTM A-992 Fy = 50 KSI ASTM A-36 Fy = 36 KSI ASTM A-36 Fy = 36 KSI ASTM A-36 Fy = 36 KSI ASTM A-53 GRADE B Fy = 35 KSI ASTM A-500 GRADE B Fy = 46 KSI ASTM A-108 E70-XX ASTM A-325N BEARING TYPE (SNUG TIGHT) ASTM A-307 OR ASTM A-36 ASTM A-307 ALL WELDING SHALL CONFORM TO THE AWS D1-1 "STRUCTURAL WELDING CODE". ALL WELDING SHALL BE PERFORMED BY A WASHINGTON ASSOCIATION OF BUILDING OFFICIALS (WABO) AND AMERICAN WELDING SOCIETY (AWS) CERTIFIED WELDERS. ALL COMPLETE PENETRATION (CP) WELDS SHALL BE ULTRASONICALLY TESTED. ALL FILLET WELDS SHALL BE VISUALLY INSPECTED. STRUCTURAL STEEL AND CONNECTIONS EXPOSED TO WEATHER SHALL BE HOT DIPPED GALVANIZED AFTER FABRICATION IN COMPLIANCE WITH ASTM A-123. ALL FIELD WELDS EXPOSED TO WEATHER SHALL BE COATED WITH BRUSH APPLIED ZINC -RICH PAINT COMPLYING WITH ASTM A-780. 03162. ADHESIVE ANCHORS IN CONCRETE ALL ADHESIVE ANCHORS SHALL BE ICC APPROVED AND INSTALLED PER ICC EVALUATION REPORT REQUIREMENTS. BOLT SPACING AND EMBEDMENTS SHALL BE AS DESIGNATED ON THE DRAWINGS TYPICAL, UNLESS NOTED OTHERWISE. ALL ADHESIVE ANCHORS SHALL BE INSTALLED WITH CONTINUOUS INSPECTION PER THE INSPECTION SCHEDULE ON SHEET S1.01, U.N.O.. P(C) = 40 PSF (LRFD) ADHESIVE -ANCHORS IN CONCRETE -SHALL BE THE FOLLOWING TYPES OR A PREAPPROVED EQUAL; POWERS PURE 110+ (ICC ESR-3298) le = 1.0 POWERS PE 1000+ (ICC ESR 2583) II POWERS AC 100+ GOLD (ICC ESR-2582) Ss = 1.49 S1 = 0.56 BOLT SIZE MINIMUM EFFECTIVE EMBEDMENT U.N.O. SITE CLASS D 1/2' DIA. OR #4 REBAR 4" SDS = 0.995 SD1 = 0.56 5/8" DIA. OR #5 REBAR 5" SEISMIC DESIGN CATEGORY D 3/4' DIA. OR #6 REBAR 6" BEARING WALL SYSTEM EQUIVALENT LATERAL FORCE INC. Structural Engineers 180 Nickerson Street Suite 302 Seattle, WA 98109 206.285.4512 (V) 206.285.0618 (F) i" SCALE: 3/4" = 1'-0' ' 1SS STRONG -BACK ATE PLATE 1/45 1/2 x -8• I/(2) 5/8' DIAMETER IMPSON TITEN-HD MINIMUM 4' EMBED) _) CONCRETE FLOOR RECEIVED CITY OF TUKWILA BASE PLATE SEP 30 2045 1 1/2' 5° VC71 1 6' PANEL � . o 0 - � - -- SCALE: 3/4' = 1'-0' BACK PLATE 1/44 x 0'-8" W/(2) 5/8' DIAMETER SIMPSON 11TEN-HD 0 24'OC (MINIMUM EMBEDMENT 4") HSS 5x2x1/4 STRONG -BACK REVIEWED FOR CODE COMPLIANCE EACH SIDE NOV 0 6 2015 City of Tukwila BUILDING DIVISION U STRONG -BACK CONNECTION V., PROJECT NAME Enterprise Installation —Fostoria Park Bldg. "C" PROJECT NO. 15241 4459 S 134th PI Tukwila, WA 98168 SCALE AS NOTED DATE 09/24/15 PAGE: S2.0