Loading...
HomeMy WebLinkAboutPermit D15-0262 - HABITAT FOR HUMANITY - TENANT IMPROVEMENTHABITAT FOR HUMANITY 1185 ANDOVER PARK W EXPIRED 07/06/I6 D15-0262 City of Tukwila ' Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 3523049093 Permit Number: D15-0262 Address: 1185 ANDOVER PARK W Issue Date: 10/30/2015 Permit Expires On: 4/27/2016 Project Name: HABITAT FOR HUMANITY Owner: Name: ICON OWNER POOL 1 WEST LLC Address: 2 N RIVERSIDE STE 2350, CHICAGO, WA, 60606 Contact Person: Name: PAUL ENGERT Phone: (206) 720-7001 Address: 2505 THIRD AVE SUITE 324, SEATTLE, WA, 98121 Contractor: Name: WALSH CONSTRUCTION CO II LLC Phone: (312) 563-5400 Address: 929 W ADAMS ST ATTN: RYAN CULL, CHICAGO, IL, 60607 License No: WALSHCC907PR Expiration Date: 10/18/2016 Lender: Name: HABITAT FOR HUMANITY Address: 560 NATCHES SE, RENTON, WA, 98057 DESCRIPTION OF WORK: TENANT ALTERATION CONSISTING OF NON-STRUCTURAL EXPANSION OF EXISTING OFFICE SPACE WITHIN EXISTING WAREHOUSE AND INFILL DOCK -HIGH DOOR WITH MATCHING STOREFRONT Project Valuation: $22,000.00 Fees Collected: $891.06 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Occupancy per IBC: M Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: Date: 0 `� J I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attache to this permit. Signature: Date: C� S Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 15: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 14: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 11: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 12: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC906.5) 13: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 16: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 17: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 18: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 19: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 20: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 24: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 22: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 21: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 25: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 26: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 27: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 28: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 23: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 29: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 30: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING V CITY OF TUKWILA Community Development Department • Public Works Department • Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.jzov Building Permit No. Project No. Date Application Accepted: Date Application Expires: use CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 3523049093 Site Tenant Name: 1185 ANDOVER PARK WEST HABITAT FOR HUMANITY PROPERTY OWNER Name: KIDDER MATHEWS Address: 631 STRANDER BLVD., SUITE 6 City: TUKWILA State: WA Z'p: 98188 CONTACT PERSON — person receiving all project communication Name: PUAL ENGERT Address: 2505 THIRD AVENUE, SUITE 324 City: SEATTLE State: WA Zip: 98121 Phone: (206) 720-7001 Fax: (206) 720-2949 Email: pAUL@CRAFTARCHITECTS.COM GENERAL CONTRACTOR INFORMATION Company Name: WALSH PACIFIC Address: 16400 SOUTHCENTER PKWY, STE 501 City: SEATTLE State: WA Zip: 98188 Phone: (206) 394-7304 Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line\2011 ApplicationsTermit Application Revised - 8-9-11.doea: Revised: August 2011 bh Suite Number: Floor: New Tenant: m .....Yes 0-No ARCHITECT OF RECORD Company Name: CRAFT ARCHITECTS Architect Name: CATHY M. CRAFT Address: 2505 THIRD AVENUE, SUITE 324 City: SEATTLE State: WA Zip: 98121 Phone: (206) 720-7001 Fax: (206) 720-2949 Email: pAUL@CRAFTARCHITECTS.COM ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: LIA Address: �. . City: PWVVtJ State: j Zip: G Page 1 of 4 I4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 22,000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): TENANT ALTERATION CONSISTING OF: NON-STRUCTURAL EXPANSION OF EXISTING OFFICE SPACE WITHIN EXISTING WAREHOUSE AND INFILL DOCK -HIGH DOOR WITH MATCHING STOREFRONT Will there be new rack storage? 0..... Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC Floor 18,661 60 2 Id Floor 3'd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? El ....... Yes Z....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ ....... Sprinklers ❑ ....... Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ID ....... Yes ❑ .......No If "yes, attach list of materials and storage locations on a separate 8-112"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑....... On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 ApplicationsTemit Application Revised - 8-9-1 Ldoav Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): N/A Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ... Water District # 125 ❑ .. Highline ❑ .. Renton ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑...Valley View ❑ .. Renton ❑ .. Seattle ❑ ...Sewer Use Certificate ❑... Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which an ❑ ...Civil Plans (Maximum Paper Size — 22" x 34" ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance El.. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ .. Right-of-way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ❑ ...Cap or Remove Utilities ❑ ❑ ...Frontage Improvements ❑ ❑ ...Traffic Control ❑ ❑ ...Backflow Prevention - Fire Protection Irrigation " Domestic Water ❑ .. Work in Flood Zone ❑ .. Storm Drainage Abandon Septic Tank Curb Cut Pavement Cut Looped Fire Line 11 ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size.. WO # ❑ ...Water Only Meter Size............ WO # ❑ ...Sewer Main Extension.............Public ❑ Private ❑ ❑ ...Water Main Extension.............Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer Monthly Service Billina to: ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Day Telephone: Mailing Address: City State Zip H:\Applications\Forte-Applications On Line\2011 ApplicationsWennit Application Revised - 8-9-1 Ldocc Revised: August 2011 Page 3 of 4 bh PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Paul Engert ii nnature� °^ °° Date: 10/01 /2015 Print Name: PAUL ENGERT Day Telephone: (206) 720-7001 Mailing Address: 2505 THIRD AVENUE, SUITE 324 SEATTLE WA 98121 City State Zip HAApplicationsWornts-Applications On Line1201 I ApplicationsTemdt Application Reused - 8-9.11.dom Revised: August 2011 Page 4 of 4 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $552.08 D15-0262 Address: 1185 ANDOVER PARK W Apn: 3523049093 $552.08 DEVELOPMENT $526.00 PERMIT FEE R000.322.100.00.00 0.00 $521.50 WASHINGTON STATE SURCHARGE 13640.237.114 0.00 $4.50 TECHNOLOGY FEE $26.08 TECHNOLOGY FEE TOTALR6547 R000.322.900.04.00 0.00 $26.08 $552.08 Date Paid: Friday, October 30, 2015 Paid By: HABITAT FOR HUMANITY Pay Method: CHECK 15161 Printed: Friday, October 30, 2015 3:15 PM 1 of 1 rwSYS7EM5 Date Paid: Monday, October 05, 2015 Paid By: CYDNIE HORWAT Pay Method: CREDIT CARD 06487A Printed: Monday, October 05, 2015 11:05 AM 1 of 1 CRSY57EM5 INSPECTION RECORD �� ���� Retain a copy with permit INSPECTION NO. PERM;T NO. CITY OI= TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 93188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project- A� Type of inspect" n: Address: ,v ve-�- Date Called: Special Instructions: Date Wanted: I. Requester: Phone ��No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: w44s o tl REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Catt to schedule reinspection. City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 6/1/2016 PAUL ENGERT 2505 THIRD AVE SUITE 324 SEATTLE, WA 98121 RE: Permit No. D 15-0262 HABITAT FOR HUMANITY 1185 ANDOVER PARK W Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/6/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. IBM 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/6/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, PAO& V Avit) Rachelle Ripley P Y Permit Technician File No: D15-0262 6300 Southcenter Boulevard Suite #100 0 Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0262 DATE: 10/05/15 PROJECT NAME: HABITAT FOR HUMANITY SITE ADDRESS: 1185 ANDOVER PARK W X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: (/ Id-1-10� /�'h� Awl lo-1-(6 CPL A)1A 10-6-/.S B ing Division ® Fire Prevention to Planning Division IN Public Works Structural ❑ Permit Coordinator 01 PRELIMINARY REVIEW: DATE: 10/06/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/03/15 Approved ❑ Approved with Conditions 1�r Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) 197.V41:1 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 WALSH CONSTRUCTION CO II ' Page 1 of 2 Home, Iriieio to .Espanol Contact Safety Washington State Department of Labor & Industries WALSH CONSTRUCTION CO II LLC Owner or tradesperson Principals WALSH, SEAN, MANAGER Doing business as WALSH CONSTRUCTION CO II LLC WA UBI No. 603 060 702 Parent company WALSH CONSTRUCTION GROUP LLC License A-! Index Help My Secure I.,&I Claims & Insurance Workplace Rights Trades & Licensing 929 W ADAMS ST ATTN: RYAN CULL CHICAGO, IL60607 312-563-5400 Business type Limited Liability Company Governing persons WALSH CONSTRUCTION G SEAN C WALSH; Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor. Active. ........................_......................................... _... _ Meets current requirements. License specialties GENERAL License no. WALSHCC907PR Effective — expiration 10/18/2010-1011812016 Bond ................ TRAVELERS CAS & SURETY CO $12,000.00 Bond account no. 100900200201037 Received by L&I Effective date 10/18/2010 10/15/2010 . Expiration date Until Canceled Insurance Arch Insurance Co $1,000,000.00 Policy no. 41 PKG8901909 Received by L&I Effective date 06/01 /2015 06101 /2015 Expiration date 06/01/2016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=603050702&LIC=WALSHCC907PR&SAW= 10/30/2015 ABBREVIATIONS V ANGLE FLUOR FLUORESCENT PS PAINT SYSTEM t CENTER LINE FM FACTORY MUTUAL PSF POUNDS PER SQUARE FOOT 0 DIAMETER OR ROUND FOC FACE OF CONCRETE PSI POUNDS PER SQUARE INCH # NUMBER OR POUND FOF FACE OF FINISH PT PRESSURE TREATED j PENNY FOIC FURNISHED BY OWNER PTD PAPER TOWEL DISPENSER 1 PERPENDICULAR INSTALLED BY CONTRACTOR PTD/R PAPER TOWEL DISPENSER It PLATE F010 FURNISHED BY OWNER AND RECEPTACLE INSTALLED BY OWNER PTN PARTITION AB ANCHOR BOLT FOS FACE OF STUD PTR PAPER TOWEL RECEPTACLE AC ACOUSTICAL FS FULL SIZE PVMT PAVEMENT A/C AIR CONDITIONING FT FEET ACP ACOUSTICAL CEILING PANEL FTG FOOTING QT QUARRY TILE ACT ACOUSTICAL TILE FTIC FURNISHED BY TENANT ADH ADHESIVE INSTALLED BY CONTRACTOR R RISER ADJ ADJACENT FTIO FURNISHED BY TENANT RA RETURN AIR AF ACCESS FLOOR INSTALLED BY OWNER RAD RADIUS AFF AT/ABOVE FINISH FLOOR FURR FURRING R&S ROD & SHELF AHJ AUTHORITY HAVING JURISDICTION FUT FUTURE RB RESILIENT BASE AL ALUMINUM FUTURE- FUTURE ROUGH IN ONLY RCP REFLECTED CEILING PLAN ALT ALTERNATE RIO RD ROOF DRAIN AP ACCESS PANEL RD/O ROOF DRAIN OVERFLOW APC ACOUSTICAL PANEL CEILING GA GAGE REBAR REINFORCING BAR APPROX APPROXIMATE GALV GALVANIZED REF REFERENCE ARCH ARCHITECTURAL GB GRAB BAR REFR REFRIGERATOR ASPH ASPHALT GC GENERAL CONTRACTOR REINF REINFORCED BD BOARD GL GLASS OR GLAZING REQ'D REQUIRED BETW BETWEEN GLB GLU-LAM BEAM REV REVISION BLK BLOCK GND GROUND RH RIGHT HAND OR ROBE HOOK BLDG BUILDING GR GRADE RESIL RESILIENT BM BEAM GWB GYPSUM WALL BOARD RM ROOM BRG BEARING RO ROUGH OPENING BOT BOTTOM HB HOSE 818 RT RESILIENT TILE BSMT BASEMENT HC HOLLOW CORE OR HANDICAP RUB RUBBER BUR BUILT UP ROOF HDR HEADER RW RAIN WATER HDWD HARDWOOD RWL RAIN WATER LEADER HDWE HARDWARE CAB CABINET HM HOLLOW METAL S SOUTH CB CATCH BASIN HORIZ HORIZONTAL SC SOLID CORE CBU CEMENTITIOUS BACKER UNIT HR HT HOUR HEIGHT SCD SEAT COVER DISPENSER CEM CEMENT HTG HEATING SCHD SD SCHEDULE SOAP DISPENSER CER CERAMIC HVAC HEATING/VENTILATION/ SECT SECTION CFM CUBIC FEET PER MINUTE AIR CONDITIONING SF SQUARE FEET CFT CONDUCTIVE FLOOR TILE HWH HOT WATER HEATER SHTG SHEATHING CG CORNER GUARD CHBD CHALK BOARD IBC INTERNATIONAL BUILDING CODE SIM SNK SIMILAR SINK Cl CAST IRON ID INSIDE DIAMETER/ SLR SEALER CJT CONTROL JOINT DIMENSION SND SANITARY NAPKIN CLF CHAIN LINK FENCE IEC INTERNATIONAL ELECTRIC DISPENSER CLG CJ CEILING CONSTRUCTION JOINT IFC CODE COUNCIL INTERNATIONAL FIRE CODE SNR SANITARY NAPKIN CLK CAULKING IG INSULATED GLAZING SPEC RECEPTACLE SPECIFICATION CLO CLOSET IHM INSULATED HOLLOW METAL SQ SQUARE CLR CMU CLEAR CONCRETE MASONRY UNIT IN INCL INCH INCLUDE SST STAINLESS STEEL CNTR COUNTER INSUL INSULATION SSK ST SERVICE SINK STONE/STONE TILE CO CLEANOUT INT INTERIOR STA STATION COL COLUMN IPC INTERNATIONAL PLUMBING CODE STC SOUND TRANSMISSION CONC CONCRETE CONSTR CONSTRUCTION JAN JANITOR STD CLASS STANDARD CONT CONTINUOUS JT JOINT STL STEEL CORR CORRIDOR CPT CARPET KIT KITCHEN STOR STORAGE CT CERAMIC TILE KO KNOCK OUT STRL SUSP STRUCTURAL SUSPENDED CTR CENTER KS KNEE SPACE SV SHEET VINYL CY CUBIC YARD SYM SYMMETRICAL LAM LAMINATE DBL DOUBLE LAV LAVATORY T TREAD DEPT DEPARTMENT LB LAG BOLT TB TOWEL BAR DF DRINKING FOUNTAIN(W/O COOLER) LF LINEAL FOOT T&B TOP & BOTTOM DIA DIAMETER LG LENGTH TG TEMPERED GLASS DIAG DIAGONAL LH LEFT HAND THK THICK DIM DIMENSION LINO LINOLEUM TIG TEMPERED INSULATED DISP DISPENSER LKR LOCKER GLAZING DN DOWN LT LIGHT TO TOP OF DR DOOR OR DRAIN TOC TOP OF CONCRETE DTL DETAIL MACH MACHINE TOP TOP OF PAVEMENT DWR DRAWER MATL MATERIAL TOS TOP OF STEEL DS DOWNSPOUT MAX MAXIMUM TOSL TOP OF SLAB DW DISHWASHER MECH MECHANICAL TOW TOP OF WALL DWG DRAWING MEZZ MEZZANINE TPD TOILET PAPER DISPENSER MFR MANUFACTURER TPH TOILET PAPER HOLDER E EAST MH MANHOLE TPTN TOILET PARTITION EA EACH MIN MINIMUM TS TUBULAR STEEL EB EXPANSION BOLT MIR MIRROR TV TELEVISION EJ EXPANSION JOINT MISC MISCELLANEOUS TYP TYPICAL EL ELEVATION MLD MOLDING ELEC ELECTRIC MRGWS MOISTURE RESISTANT GWB UL UNDERWRITERS LABORATORY ELEV ELEVATOR MTD MOUNTED UNF UNFINISHED EM ENTRY MAT MTL METAL UON UNLESS OTHERWISE NOTED EMER EMERGENCY MULL MULLION UR URINAL ENCL ENCLOSURE OR ENCLOSED EP ELECTRICAL PANEL N NORTH VAR VARIES EWC ELECTRIC WATER COOLER NIC NOT IN CONTRACT VCT VINYL COMPOSITION TILE EPX EPDXY NO/# NUMBER VERT VERTICAL EQ EQUAL NOM NOMINAL VEST VESTIBULE EQUIP EQUIPMENT NTS NOT TO SCALE VIN VINYL EST ESTIMATE OA OVERALL VWC VINYL WALL COVERING EX EXPANSION OC ON CENTER EXIST EXISTING OD OUTSIDE DIAMETER/ W WEST EXT EXTERIOR DIMENSION W/ WITH FA FIRE ALARM OFF OFFICE W/O WC WITHOUT WATER CLOSET FAO FURNISHED BY OTHERS OH OVERHEAD WD WOOD FCIC FURNISHED BY CONTRACTOR OPH OPNG OPPOSITE HAND OPENING WF WIDE FLANGE INSTALLED BY CONTRACTOR OPP OPPOSITE WG WIRE GLASS FCTY FACTORY WHSE WAREHOUSE FD FLOOR DRAIN PERP PERPENDICULAR WP WATER PROOF FDN FOUNDATION PFN PREFINISHED WR WATER RESISTANT FE FIRE EXTINGUISHER PL PLATE OR PROPERTY LINE WSCT WAINSCOT FEC FIRE EXTINGUISHER CABINET PLAM PLASTIC LAMINATE WEIGHT FF FACTORY FINISH PLYWD PLYWOOD FIN FINISH PNL PANEL XFMR TRANSFORMER FL FLOOR PNT PAINT YD YARD FLG FLASHING PR PAIR SYMBOLS COLUMN LINE/GRID LINE DOOR/RELITE NUMBER CORRESPONDS TO ROOM ENTERING 1078 OX KEY NOTE Wj PARTITION TYPE X REVISION NUMBER REVISION CLOUD AROUND REVISION MATCH LINE — — SHADED PORTION IS THE SIDE CONSIDERED WORK POINT, CONTROL POINT OR DATUM POINT 1492 EQUIPMENT NUMBER BUILDING SECTION SECTION IDENTIFICATION SHEET WHERE SECTION IS DRAWN DETAIL SECTION SECTION IDENTIFICATION SHEET WHERE SECTION IS DRAWN X DETAIL OR ENLARGED PLAN AU DETAIL IDENTIFICATION SHEET WHERE DETAIL IS DRAWN GENERAL NOTES NDO 'NINDOW SYMBOL A INTERIOR ELEVATION(S) D AX.X B--- ELEVATION IDENTIFICATION SHEET WHERE ELEVATION IS DRAWN TITLE ROOM IDENTIFICATION TITLE2 TITLE3 ROOM NAME' ROOM ROOM NO. FINISHED CEILING HEIGHT — — PROPERTY LINE j8 NEW OR FINISHED CONTOURS 71 EXISTING CONTOURS TOP OF WALL G 1 TOP OF CURB 15 k TOP OF PAVEMENT PNSTHT N PROJECT NORTH DENOTES CHANGE IN 7,-0" ELEVATION PT FINISH SYMBOL 2 1. THE GENERAL CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS ON THE JOB SITE, INCLUDING THE SAFETY OF ALL PERSONS, PROPERTY, AND FOR ALL NECESSARY INDEPENDENT ENGINEERING REVIEWS OF THESE CONDITIONS, AND FOR COMPLIANCE WITH O.S.H.A. SAFETY STANDARDS. ARCHITECTS AND THEIR CONSULTANTS' JOB SITE OBSERVATIONS ARE NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES. 2. EACH CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH ALL SPECIFIED PRODUCTS RELATING TO THEIR WORK. THE( ARE TO SUBMIT WRITTEN OBJECTIONS PRIOR TO BIDDING, IF THE CONTRACTOR HAS AN OBJECTION TO ANY PRODUCT AND/OR DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS. 3. THE GENERAL CONTRACTOR SHALL COORDINATE THEIR WORK WITH THAT OF OTHER SEPARATE CONTRACTS SUCH AS SIGNS, & OWNER FURNISHED ITEMS, WHICH ARE BEING DONE BY OTHERS. 4. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS. ALL WORK IN THAT AREA SHALL BE HELD UNTIL SUCH DISCREPANCIES ARE RESOLVED. 5. SEPARATE PERMITS, WHEN REQUIRED AND/OR WHEN WORK ITEMS ARE DESIGN/BUILD IN NATURE, SHALL BE OBTAINED BY THE CONTRACTOR FOR MECHANICAL, PLUMBING, FIRE SPRINKLERS, ELECTRICAL AND FIRE ALARM. DESCRIPTIVE, DETAILED DESIGN AND REGUIRED SUBMITTAL DOCUMENTS INFORMATION SHALL BE PROVIDED FOR REVIEW BY THE REGULATING AUTHORITIES AND BY THE OWNER/TENANT/ARC-IITECT FOR APPROVAL PRIOR TO ANY WORK BEING PERFORMED. SEE SPECIFICATIONS FOR REQUIREMENT FOR DESIGN/BUILD FIRE SPRINKLER SYSTEM. SUBMIT PLAN TO AND OBTAIN PERMIT FROM THE AUTHORITY HAVING JURISDICTION FOR FIRE SPRINKLER SYSTEM INSTALLATION OR MODIFICATION. ALL WORK SHALL COMPLY WITH CURRENT GOVERNING CODES. 6. SPECIAL INSPECTIONS WHERE REQUIRED BY THE BUILDING OFFICIAL SHALL BE PERFORMED BY INSPECTORS APPROVED BY THE BUILDING OFFICIAL. 7. ALL WORK DONE SHALL BE IN CONFORMANCE WITH THE APPROVED PLANS AND PROJECT SPECIFICATIONS. THE APPROVED, PERMITTED, STAMPED PLANS ARE TO REMAIN ON SITE AT ALL TIMES. ANY MODIFICATIONS TO WORK SHALL BE INDICATED ON FIELD "AS -BUILT„ SET OF DOCUMENTS. 8. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UON. 9. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. 10. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF QUESTIONS CAN NOT BE RESOLVED IN THIS MANNER, CONTACT THE ARCHITECT PRIOR TO PROCEEDING. 11. GENERAL CONTRACTOR SHALL PROVIDE OWNER AND ARCHITECT WITH DETAILED CRITICAL PATH SCHEDULE FOR REVIEW AND APPROVAL PRIOR TO START OF CONSTRUCTION. UPDATES OF SCHEDULE SHALL BE MADE AS NECESSARY WITH COPIES PROVIDED TO OWNER AND ARCHITECT. 12. ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH CURRENT GOVERNING CODES. NOTHING IN THESE DRAWINGS IS TO BE CONSTRUED AS TO PERMIT WORK WHICH IS NOT CONFORMING TO CURRENT GOVERNING CODES. 13. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ADJACENT PROPERTY AT ALL TIMES DURING CONSTRUCTION. 14. THE CONTRACTOR SHALL COMPLY WITH ALL CURRENT APPLICABLE LOCAL ORDINANCES FOR UTILITY SERVICE PROVIDERS, PUBLIC AND/OR PRIVATE. 15. FIRE BLOCKING SHALL BE PROVIDED AT ALL FRAMED WALLS AT 10'-0" O.C. AND ALSO AT ANY LOCATION WHERE WALL FRAMING PENETRATES CEILINGS. REFER TO IBC SEC. 708 FIRE BLOCKING AND DRAFT STOPS FOR CONSTRUCTION. 16. PATCH AND REPAIR ALL EXISTING WALLS, FLOORS AND CEILINGS THAT ARE ADJACENT TO AND AFFECTED BY NEW CONSTRUCTION. 17. ASBESTOS AND HAZARDOUS WASTE EXCLUSION: THE ARCHITECT HEREBY STATES, AND THE OWNER ACKNOWLEDGES, THAT THE ARCHITECT HAS NO PROFESSIONAL LABILITY OR OTHER INSURANCE, (AND IS UNABLE TO REASONABLY OBTAIN SUCH INSURANCE) FOR CLAIMS ARISING OUT OF THE PERFORMANCE OF DR THE FAILURE TO PERFORM PROFESSIONAL SERVICES, INCLUDING BUT NOT LIMITED TO, THE PREPARATION OF REPORTS, DESIGNS, DRAWINGS, AND SPECIFICATIONS, AND RELATED TO THE INVESTIGATION DETECTION. PLUMBING FIXTURE REQ'S NOTE: PLUMBING FIXTURES ARE EXISTING; SCOPE OF WORK DOES NOT INVOLVE OCCUPANCY CHANGES OR DOES NOT INCREASE FIXTURE REQUIREMENTS. SEPARATE PERMIT T REQUIRED FOR; Mechanical ff K ctdical mbing s Piping City of Tukwila BUIt-DING DIVISItim APPROVED BY: PROJECT DIRECTORY Datels Date ARCHITECT/CONTACT: CRAFT ARCHITECTS, PLLC. CONTACT: PAUL ENGERT €w ` 2505 THIRD AVE, STE. 324 PHONE: (206) 720-7001 Habitat SEATTLE, WASHINGTON 98121 EMAIL: PAUL@CRAFTARCHITECTS.COM for Humanity' ' OWNER: KIDDER MATHEWS CONTACT: ANDREA HACKER 631 STRANDER BLVD. SUITE 6 PHONE: (253) 893-1154 TUKWILA, WASHINGTON 98188 EMAIL: AHACKER®KIDDERMATHEWS.COM TENANT: HABITAT FOR HUMANITY CONTACT: CYDNIE HORWAT PHONE: (425) 466-4499 EMAIL: CYDNIE.HORWAT®HABITATSKC.ORG a >r c h 1 t e c t s GENERAL CONTRACTOR: WALSH PACIFIC CONTACT: SCOTT LEE 2505 Third Avenue 16400 SOUTHCENTER PARKWAY PHONE: (206) 394-7304 Suite 324 SUITE 501 EMAIL: SLEE®WLASHGROUP.COM Seattle, WA 98121 SEATTLE, WASHINGTON 98188 206.720.7001 phone 206.720.2949 fax VICINITY MAP TAX PARCEL # 3523049093 LEGAL DESCRIPTION POR OF NW 1/4 OF NE 1/4 OF SEC 35-23-04 TGW POR OF SW 1/4 OF SE 1/4 OF SEC 26-23-04 - BEG NE COR OF NW 1/4 OF NE 1/4 OF SEC 35-23-04 TH N 87-44-08 W ALG N LN OF SD SEC 30 FT TO W MGN OF ANDOVER PARK WEST & TPOB TH S 01-51-39 W ALG SD W MGN 681.34 FT TH N 87-55-02 W 270 FT TH N 01-51-39 E 682.19 FT TH N 01-51-39 E 114.81 FT TH S 87-55-02 E 270 FT TO W MGN OF ANDOVER PARK WEST TH S' 01-47-29 W ALG SD W MGN 115.66 FT TO TPOB LESS POR FOR ACCESS RD CODE/ZONING INFORMATION GOVERNING BUILDING CODES: 2012 IBC 2012 UPC 2012 IFC 2009 ICC/ANSI A117.1 (ACCESSIBILITY) 2012 IECC REGULATIONS & ORDINANCES 2012 WASHINGTON STATE AMENDMENTS 2012 WASHINGTON STATE ENERGY CODE VENTILATION PER IMC ZONING DISTRICT: TUC EXISTING/NEW OCCUPANCY CLASSIFICATION: B (OFFICE)/M (MERCANTILE) TYPE OF CONSTRUCTION: III-B SPRINKLER SYSTEM: FULLY SPRINKLERED FLOOR AREAS: OFFICE (EXISTING) (B) 928 SQ FT OFFICE (NEW) (B) 60 SQ FT MERCANTILE (EXISTING) (M) 17,733 SQ FT TOTAL FLOOR AREA: 18,720 SQ FT REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. j %#1ty uT ! umia BUILDING DIVISION SITE/BUILDING PLAN NTS 4 PROJECT DESCRIPTION TENANT ALTERATION CONSISTING OF: NON-STRUCTURAL EXPANSION OF EXISTING OFFICE SPACE WITHIN EXISTING WAREHOUSE AND INFILL DOCK -HIGH DOOR WITH MATCHING STOREFRONT INDEX OF DRAWINGS T1.1 GENERAL INFORMATION & SITE PLAN T1.2 ACCESSIBILITY GUIDELINES A2.1 FLOOR/EGRESS AND DEMOLITION PLANS A2.2 REFLECTED CEILING PLAN, DOOR SCHEDULE AND PARTITION TYPES PARKING REOUIRE ENTS NOTE: PARKING STALLS ARE EXISTING. SCOPE OF WORK DOES NOT INVOLVE OCCUPANCY CHANGES OR BUILDING SQUARE FOOTAGE INCREASES. REVt-WED FOR ODE COMPLIANCE Ano6n% r% www.craftarchitects.com 7052 REGISTVARCHITECT YN M. CRAFT STATE WASHiN(W Submittals/Revisions: Sheet No: T101 COPYRIGHT CRAFT ARCHITECTS 2015 M221M FLOOR SURFACES A CHANGES IN LEVEL ANSI/ICC A117.1 303 - CHANGES IN LEVEL (REFERENCE DETAIL) A. Changes in level up to 1/4" may be vertical and without edge treatment B. Changes in level between 1/4" and 1/2" shall be beveled with a slope no greater than 1:2. IN i 2 •:t •\ J E l --- .SAW ANSI/ ICC A117.1 302.2 CARPET A. Carpet provided on a floor surface shall be securely attached; have a firm pad or backing, or no pad; and have a level loop, textured loop, level cut pile, or level cut/uncut pile texture. Maximum pile thickness shall be 1/2". Exposed edges of carpet shall be fastened to floor surfaces and have trim along the exposed edges. ANSI/ICC A117.1 302.3 - GRATINGS A. If gratings are located in walking surfaces or along accessible routes, then they shall have spaces no greater than 1/2" wide in one direction. B. If gratings have elongated openings, then they shall be placed so that the long dimension is perpendicular to the dominant direction of travel. 305 GM FLOOR SPACE ANSI/ICC A117.1 305.2 - SIZE AND APPROACH A. Minimum clear floor space for a wheelchair and occupant shall be 3T wide x 48" long. Clear floor space shall be centered on the element it serves. 404 DOORS continued 502/503 PARKING AND PASSENGER LOADING ZONES continued 604 WATER CLOSETS do TOILS? WMIRAMEM conUn6W GRAB BARS ANSI/ICC A117.1 404.2.6 - DOOR HARDWARE ANSVICC A117.1 502.7 - SIGNAGE (REFERENCE DETAIL) ANSI/ICC A117.1 604.7 - DISPENSERS (REFERENCE DETAIL) ANSI/ICC A117.1 609.3.2 - SIZE AND SPACING A. Handles, pulls, latches, locks, and other operating devices shall have a shape that is A. Each accessible parking space must have individual vertically mounted or suspended A. Toilet paper dispensers shall comply with Section 309.4 and 609.3. Where the A. Diameter or width of gripping surface shall be 1-1 4" to 0 g pp g / 7', r the shape shall easy to grasp with one hand and does not require tight grasping, tight pinching, or sign. Required van accessible spaces must be designated. dispenser is located above the grab bar, the outlet of the dispenser shall be located provide an equivalent gripping surface. twisting of the wrist to operate. B. Characters and symbols on such signs shall be located 60" minimum above the 24 min-36" max from the rear wall. Where the dispenser is located below the grab 1. The space between grab bars and adjacent walls shall be 1-1/2" 1. Lever -operated mechanisms, push -type mechanisms, and U-shaped handles are ground. bar, the outlet of the dispenser shall be located 24" min-42" max from the rear acceptable designs. wall. The outlet of the dispenser shall be 18"-4T maximum A.F.F. ANSI/ICC A117.1 609.8 - STRUCTURAL STRENGTH 2. When sliding doors are fully open, operating hardware shall be exposed and usable ANSI/ICC A117.1 503.5 - VERTICAL CLEARANCE 1. Disp-nsers that control delivery or do not permit continuous paper flow shall not A. Grab bars and mounting devices shall meet the following requirements: from both sides. A. Provide minimum vertical clearance of 114" at accessible passenger loading zones be used. 609.8 Allowable stresses shall not be exceeded for materials used where a vertical 3. Hardware required for accessible door passage shall be mounted between 34 and and along at least one vehicle access route from site entrances and exits. or horizontal force of 250 lbs. is applied at any point on the grab bar, fastener 48" above finished floor. ANSI/ICC A117.1 604.9 WHEELCHAIR ACCESSIBLE COMPARTMENTS mounting device, or supporting structure: ANSI/ICC A117.1 503 -PASSENGER LOADING ZONE A. Wheelchair accessible compartments shall comply with Section 604.9. Toilet 1. Shear stress induced by application of 250 lb. shall be less than allowable shear ANSI ICC A117.1 404.2.7.1 - DOOR CLOSERS / A. Passenger loading zones shall provide an access aisle at least 60" wide and 20. ft compartments shall comply with Section 604.9.2.1 or 604.9.2.2 as applicable. stress for material used. If connection between grab bar and mounting bracket A. Door closers shall be adjusted so that from an open position of 90 degrees, the Ion adjacent and parallel to the vehicle ull-u space. If there are curbs between 9 J P P P P is considered to be fully restrained, then direct and torsional shear stresses shall time required to move the door to an open position of 12 degrees shall be 5 the access aisle and the vehicle pull-up space, then a curb ramp complying with 4.7 be totaled for the combined shear stress, which shall not exceed the allowable seconds minimum. shall be provided. Vehicle standing spaces and access aisles shall be level with __711 54 MIN shear stress. surface slopes not exceeding 1:48 in all directions. „ 2. Shear force induced in a fastener or mounting device from application of 250 lb. ANSI/ICC A117.1 404.hing -SPRING HINGES 39 -41 shall be less than allowable lateral load of either the fastener or mounting device A. Door spring hinges shall be adjusted so that from the open position of 70 degrees, GALVANIZED MOUNTING BOLTS or the supporting structure, whichever is the smaller allowable load. the door shall move to the closed position in 1.5 seconds minimum. - 12" MAX 42" MIN 36" MIN. 3. Tensile force induced in a fastener by a direct tension force of 250 lb. plus the I ]maximum moment from the application of 250 lb. shall be less than the ANSI/ICC A117.1 maximum and IBC with WA STATE AMENDMENTS o DOOR OPENING FORCE $0 12" 24 allowable withdrawal load between the fastener and the supporting structure. Locate flush controls A. The maximum force for pushing or pulling open a door shall be as follows: on wide aide 609.E Grab bars shall not rotate within their fittings. 1. Fire doors shall have the minimum opening force allowable by the appropriate STATE . " administrative authority. M ANSVICC A117.1 609.5 - ELIMINATING HAZARDS 2. Other doors - I b„ I A. Grab bars and adjacent wall surfaces shall be free of sharp or abrasive surfaces. a. Exterior hinged, sliding or folding door. 10.0 lb. max. REQUIRED , M M Edges shall be rounded. b. Interior hinged doors: 5.0 lb. max. o ACC E BLE11 c. Interior sliding or folding doors: 5.0 lb. max. z\__These forces do not apply to the force required to retract latch bolts or disengage M C) M _Tz other devices that may hold the door in a closed position. 'b o N PRE-MANUF. SIGN Side Wall Grab Bar for Water Closet Rear Wall Grab Bar for Water Closet I m 4 DIA. STEEL POST W/ CAP 702 Ln p FINISH GRADE ANSI/ICC A117.1 702.1 - GENERAL ".I SET Post IN CONIC. A. When required, visual alarms shall be provided in each of the following areas, as a 40$ CURB PS :. ;I I 36" MAX 36" MAX 1 I. minimum: rest rooms and any other general usage areas (e.g., meeting rooms), I yQff; INSTALL SIGN AT ALL ACCESSIBLE PARKING I I 24" MIN hallways, lobbies, and an other area for common use. ANSI/ICC A117.1 406 - SLOPE (REFERENCE DETAIL) , I F , STD• SPACES DESIGNATED FOR VAN PARKING Z Ys Y 307 MINDING OgJECjS (REFERENCE DETAILS) A. Slopes of curb rams shall comply with 406 d I SHALL HAVE ADDITIONAL SIGN "VAN ACCESSIBLE' P p py ",I, MOUNTED BELOW. MOUNT ON WALL OF BLDG WHEN Accessible audible and visible alarms and notification appliances shall be installed in B. Maximum slopes of adjoining gutters, road surface immediately adjacent to the curb POSSIBLE. accordance with NFPA 72. ANSVICC A117.1 307 -GENERAL ramp, or accessible route shall not exceed 1:20, A. Objects projecting from walls (for example, telephones) with their leading edges QgS4!! - - NFPA 72 - AUDIBLE ALARMS between 27"-80" above the finished floor shall protrude no more than 4" into walks, ANSI/ICC A117.1 406.4 - WIDTH (REFERENCE DETAIL) : 'b z A. If provided, audible alarms shall produce a sound that exceeds the prevailing halls, corridors, passageways, or aisles. Freestanding objects mounted on posts or A. The minimum width of a curb ramp shall be 36", exclusive of flared sides. 5g 5 equivalent sound level in the room or space by at least 15 dba or exceeds any pylons may overhang 12" maximum from 27"-80" above the ground or finished 1 L,,/, maximum sound level with a duration of 60 seconds by 5 dba, whichever is louder. floor. Protruding objects shall not reduce the clear width of an accessible route or ANSI/ICC A117.1 406.3 - SIDES OF CURB RAMPS (REFERENCE DETAIL) 602 Df NKING FDUNTAINS \ \ B. Sound levels for alarm signals shall not exceed 120 dba. maneuvering space. A. If a curb ramp is located where pedestrians must walk across the ramp or where it , ,ANSI/ICC A117.1 602.1 - GENERALNFPA 72 - VISUAL ALARMS is not protected by handrails or guardrails, it shall have flared sides; the maximum A. Accessible drinking fountains shall comply with Sections 602 and 307. 4" MIN 4" MIN slope of the flare shall be 1:10 47, 42" AX A. Visual alarm signal appliances shall be integrated into the building or facility alarm system. If single station audible alarms are provided then single station visual alarm ANSI/ICC A117.1 602.2 - CLEAR FLOOR SPACE signals shall be provided. . . ___.. 4" MAX. CLEAR WIDTI•I ANY AMOUNT 9 Ddd 3W & 309 REACH RANGES AND OPERABLE PARTS ANSI/ICC A117.1 308 - HEIGHT (REFERENCE DETAIL) A. Unobstructed front approach - 4T max. to 15' min. A.F.F. Controls located in an alcove >24" deep must have 3T clear floor width. B. Unobstructed side approach - 48" max. to 15" min, A.F.F. Controls located in an alcove >15' deep must have 60" clear floor width. C. Obstructed front approach, 20" max depth - 48" max. A.F.F. forward reach D. Obstructed front approach, >20"-25" max depth - 44" max. A.F.F. forward reach E. Obstructed side approach, 10" max depth and 34" max height obstruction, 4T max. A.F.F. side reach F. Obstructed side approach, >1O"-24" max depth and 34" max height obstruction, 46" max. A.F.F. side reach G. Electrical & communication system receptacles shall be mounted no less than 15' above the floor. ANSI/ ICC A117.1 309 - OPERABLE PARTS Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5.0lbs maximum. 403 ACCESSIBLE ROUTE - WALKING SURFACES IBC 1104 - LOCATION A. At least one accessible route shall be provided from public transportation stops, accessible parking and loading zones, and public streets or sidewalks to the accessible building entrance. B. Pedestrian route connections shall be clearly demarked where it crosses drive aisles. Method of demarkation shall match existing in shopping center painted str;ping. ANSI/ICC A117.1 403.5 - CLEAR WIDTH A. The minimum clear width shall be 32" at a point for a max. length of 24" and 36" continuously, per Table below. MINIMUM SEGMENT LENGTH SEGMENT WIDTH less than or 37 equal to: 24 greater than: 24 36r IBC with WA STATE AMENDMENTS 1101.2.2 - CLEAR WIDTH A. Clear width of an accessible route shall comply with Table above. For exterior routes of travel, the minimum clear width shall be 44". ANSI/ICC A117.1 403.5.2 - PASSING SPACE A. If an accessible route is less than 60" in width, then passing spaces of at least 60"x60" shall be provided at 200' max. spacing. B. The minimum clear width for two wheelchairs to pass is 60" ANSI/ICC A117.1 307.2 IBC 1009.2 and 1010.5.2 A. Accessible routes shall have 80" min. clear head room. ANSI/ICC A117.1 403.3 - SLOPE A. Running slope shall not exceed 1:20. B. Cross slope shall not exceed 1:48 404 000R~S ANSI/ICC A117.1 404.2.1 - DOUBLE - LEAF DOORWAYS A. Doorways with two independently operated leaves shall have at least one active leaf that meets the requirements in 404.2,2 and 404.2.3 ANSI/ICC A117.1 404.2.2 - CLEAR WIDTH A. Doorways shall provide a clear opening of 32" minimum, with the door open 99. 1. Clear opening shall be measured between the face of the door and opposite stop. 2. Openings more than 24" in depth shall provide a clear opening of 36' minimum. ANSI/ICC A117.1 404.2.3 - MANEUVERING CLEARANCES AT DOORS Provide level (1:48 max. slope) and clear maneuvering area at doors as follows: A. Front approach pull side - 60" min. width & 18" min. beside strike edge Front approach push side - 48" min width & 0" beside strike edge (12" 0 strike if door has both a closer and a latch) B. Hinge side approach pull side - 60" min. width; 36" min. beside strike edge or - 54" min. width; 42" min. beside strike edge Hinge side approach push side - 42" min. width & 22" min. beside hinge edge (48"min. width if door has both a closer and a latch) C. Latch side approach pull side - 48" min. width and 24" min. beside strike edge (54"min. width if door has a closer) Latch side approach push side - 42" min, width and 24" min. beside strike edge (0min. width if door has a closer) ANSI/ICC A117.1 404.2.4 - THRESHOLDS AT DOORWAYS A. Maximum threshold height: 1/2". Raised thresholds and floor level changes shall be beveled with a slope no greater than 1:2 If x Is less than 4Er Then The Slope Of The Fli Sides Shall Not Exceed 1: inn 110 Max. slope Standard Curb Ramo Adjoining Sloppe Shall Not Exceed 1:20 .l \ 1:12Max. slope Curb Ramp Parallel to Curb Ddd Adjoining Sloppe Shall A. A clear floor space complying w/ Section 305, positioned for a forward approach Protruding Dispenser Protruding Dispenser Recessed Dispenser Visual Alarm appliances shall have the following features: Not Exceed 1:20 to the drinking fountain, shall be provided. Knee & toe space complying with Below Grab Bar Above Grab Bar 1. The lamp shall be a xenon strobe type or equivalent. Section 306 shall be provided. The clear floor space shall be centered on the 2. The color shall be clear or nominal white (i.e. unfiltered or clear filtered white Flared side drinking fountain. EXCEPTIONS: 1. Drinking fountains for standing persons. - URINALS light). 3. The maximum pulse duration shall be two -tenths of one second with a maximum duty cycle of 40%. (The pulse duration is defined as the time interval between :; 2. Drinking fountains primarily for children's use. 3. In existing building, existing drinking fountains providing a parallel approach initial and final points of 10% of max signal) complying w/ Section centered on the drinking fountain shall be permitted. ANSI ICC A117.1 _ / 605 URINALS 4. The intensityshall be a minimum of 75 candela. 4. Where specifically ermitted b the administrative autho' a a permitted pe y p y authority, parallel approach A. Accessible urinals shall comply with Section 605. PY n 5. The flash rate shall be a minimum of 1 Hz and a maximum of 3 Hz 6. The appliance shall be placed 80" above the highest floor level within the space Ramp (1:12 Max. Slope) Shall Have Detectable shall be permitted that replace existing parallel approach drinking fountains. ANSI/ICC A117.1 605.2 - HEIGHT & DEPTH (REFERENCE DETAIL) or 6' below the ceiling, whichever is lower. amings and contrasting color. ANSI/ICC A117.1 602.3 - OPERABLE PARTS A. Urinals shall be stall -type or wall hung with a tapered, elongated rim at 17" a. In large rooms and spaces exceeding 100' across, without obstructions 6' A. Operable parts shall comply with Section 309. maximum above the finished floor. The rim shall extend a minimum of 1W from the wal. above the finished floor, such as auditoriums, devices may be place around the perimeter, spaced a maximum 100' apart, in lieu of suspending appliances from 6" Min. ANSI/ICC A117.1 602.4 - SPOUT OUTLET HEIGHT A. Wheelchair accessible spout outlets shall be 36 inches max. off. Standing person ANSI/ICC A117.1- 605.3 - CLEAR FLOOR SPACE (REFERENCE DETAIL) the ceiling. 7. In general, no place in any room or space shall be more than 50' from the spout outlets shall be 38 inches min. & 43 inches max. off. A. A clear floor space 30" wide by 48" deep minimum shall be provided in front of signal (measured in a horizontal plane). P-Locartlon ANSI/ICC A117.1 602.5 - SPOUT LOCATION urinal b allow forward approach. 1. This space shall adjoin or overlap an accessible route. 8. No place in common corridors or hallways shall be more than 50' from the signal. f Typical Parking A. Spout shall be located 15 inches min. from the vertical support and 5 inches max. 2. Urinal shields that do not extend beyond the front edge of the urinal rim may be 703 SIGNAGE Access Aisle from the front edge of the drinking fountain, including bumpers. provided with 29" clearance between them. /` 3. Urinals installed in alcoves deeper than 24 require a maneuvering area of at WHERE APPLICABLE ANSI/ICC A117.1 602.6 - WATER FLOW least 36' minimum wide, centered on fixture. A. Signs which designate permanent rooms and spaces shall comply with the Ramps (1:12 Max. Slope) Shall Have Detectable Wamings A. Spout shall provide a flow of water 4 inches min. in height. The angle of the water stream from spouts within 3 inches of the front of the drinking fountain shall be 30 ANSI/ICC A117.1 605.4 - FLUSH CONTROLS (REFERENCE DETAIL) requirements listed below for. 1. Raised and Braille Characters, and Pictograms and contrasting color. degrees max. and from spouts between 3 inches & 5 inches from the front of the Controls shall coin ply with ANSI/ICC A117.1 309 OPERABLE PARTS 2. Finish and Contrast Note : If Slope is 1:20 or less no drinking fountain shall be 15 degrees max., measured horizontally relative to the contrasting color or texture is required front face of the drinking fountain. Exception: Employee name signs are not required to comply. WHERE APPLICABLE TMAX 15"MIN A. Signs which provide direction to, or information about, functional spaces of the build;. shall co I 'th th t 1' ted b I f ANSI/ICC A117.1 406.10 - DIAGONAL CURB RAMPS A. If diagonal curb ramps have returned curbs or other well-defined edges, such edges shall be parallel to the direction of pedestrian flow. The bottom of diagonal curb ramps shall have 48" minimum clear space outside active traffic lanes of the roadway. If diagonal curb ramps are provided at marked crossings, the 48" clear space shall be within the markings. If diagonal curb ramps have flared sides, they shall also have at least a 24" long segment of straight curb located on each side of the curb ramp and within the marked crossing. ANSI/ICC A117.1 406.11 - ISLANDS A. Any raised islands in crossings shall be cut through level with the street or curb ramps at both sides and a level area at least 48" long and 36" minimum wide between the curb ramps in the part of the island intersected by the crossings. _____ ___ g mpy wi a -4- I---- s Is eow or. j 1. Character Proportion I a 2. Character Height 48" MIN. 8 Ilk3. Finish and Contrast u______----- Exception: Building directories, menus, and all other signs which are N I temporary are not required to comply. . ^b I :t >M I WHERE APPLICABLE (REFERENCE DETAIL) Forward proach 1` ci o '------44N A. Element and spaces of accessible facilities which shall be Identified by the E C International Symbol of Accessibility are: 0 0 1. Parking spaces designated as reserved for persons with disabilities. Ddd Ddd 2. Accessible passenger loading zones. W3 MET ROOMS 3. Accessible entrances when not all are accessible (inaccessible entrances shall have directional signage to indicate route to nearest accessible entrance) ego E N ,Is E r •.: - •• • . Letter & numbers on signs shall have a width to height ratio of between 3:5 & 1:1 and a stroke - width to height ratio between 1:5 & 1:10. Letters and numbers shall be raised 1/32", upper case, sans serif or simple serif type and shall be accompanied with grade 2 Braille, raised characters shall be at International Symbol least 51T - 3" high plus 1/6" per foot of viewing distance above 21 feet. of Accessibility Ddd 22id Light switch 8" MAX Thermostats, Etc. w -\\ - ? z w Wu zg am 0 U Q z ` , , 0 0 = • 9_ b(o I- Convenience Outlets Ddd Data, Tel., Etc. 707 AUMM11C TELLER MAMINES ANSI/ICC A117.1 707.2 CLEAR FLOOR SPACE A. Floor space shall comply with ANSI/ICC A117.1 305 to allow a forward, parallel approach or both. ANSI/ICC A117.1 707.3 OPERABLE PARTS A. Operable parts shall be placed within one or more of the reach ranges specified in ANSI/ICC A117.1 section 309, summarized earlier in this sheet. W4 KITCHENS AND KITCHENETTES ANSI/ICC A117.1 804.5.6 - REFRIGERATOR/FREEZER Combination refrigerators and freezers shall have at least 50% of the freezer compartment shelves, including the bottom of the freezer 54 inches (1370mm) maximum above the floor when the shelves are installed at the maximum heights possible in the compartment. A clear floor space, positioned for a parallel approach to the space dedicated to a refrigerator/freezer, shall be provided. The centerline of the clear floor space shall be offset 24 inches (610 mm) maximum from the centerline of the dedicated space. 902 DINING SURFACES & FORK SURFACES ANSI/ICC A117.1 902.2 - CLEAR FLOOR SPACE A. A clear floor space complying with Section 305, positioned for a forward approach, shall be provided. Knee and toe clearance complying with Section 306 shall be provided. ANSI/ICC A117.1 902.4- HEIGHT A. The tops of accessible tables and counters shall be 28" minimum, and 34" maximum, above the finished floor. 903 BENCHES ANSI/ICC A117.1 903.2 - CLEAR FLOOR SPACE A. a clear floor space complying with section 305, positioned for parallel approach to the bench seat shall be provided. ANSI/ICC A117.1 903.3- SIZE A. Benches shall have seats 42" minimum in length and 20" minimum and 24" maximum in depth. ANSI/ICC A117.1 903.4 - BACK SUPPORT A. The bench shall provide for back support or shall be fixed to a wall. Back support shall be 42" minimum in length and shall extend from a point 2" maximum above the seat surface to a point 18" above the seat surface. ANSI/ICC A117.1 603.2.2 - DOORS 6Q$ LAVATORIES 4. Accessible toilet and bathing facilities when not all are accessible. A. Doors shall not swing into the clear floor space or clearance for any fixture. goSTORAGE ANSIACC A117.1 606.3 & 606.2 - HEIGHT & CLEARANCES (REFERENCE DETAILS) ANSI/ICC A117.1 703.2.4 -CHARACTER HEIGHT (REFERENCE DETAIL) " 410 PLATFORM LIFTS ANSI/ICC A117.1 410.1 - GENERAL A. Platform lifts shall comply with Section 410 and ASME A18.1 listed in Section 105.2.6. Platform lifts shall not be attendant operated and shall provide unassisted entry and exit from the lift. ANSI/ICC A117.1 410.2 - LIFT ENTRY A. Lifts with doors or gates shall comply with Section 410.2.1. Lifts with ramps shall comply with Section 410.2.2. ANSI/ICC A117.1 410.2.1 - DOORS AND GATES A. Doors and gates shall be low energy power operated doors or gates complying with Section 404.3. Doors shall remain open for 20 seconds minimum. End door clear opening width shall be 32 inches minimum. Side door clear opening width shall be 42 inches minimum. Exception: Lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self closing manual doors or gates. ANSI/ICC A117.1 410.2.2 - RAMPS A. End ramps shall be 32 inches minimum in width. Side ramps shall be 42 inches minimum in width. ANSI/ICC A117.1 410.3 - FLOOR SURFACES A. Floor surfaces of platform lifts shall comply with Section 302 ANSI/ICC A117.1 410.4 - PLATFORM TO RUNWAY CLEARANCE A. The clearance between the platform sill and the edge of any runway landing shall be 1 1/4 inch maximum ANSI/ICC A117.1 410.5 - CLEAR FLOOR SPACE A. Clear floor space of platform lifts shall comply with Section 305. ANSI/]CC A117.1 410.6 - OPERABLE PARTS A. Controls for platform lifts shall comply with Section 309. 502M PARKING AND PASSENGER LAIADING ZONES ANSI/ICC A117.1 502 - PARKING SPACES A. Accessible car parking spaces shall be 96" minimum in width. Van parking spaces shall be 132" minimum in width. EXCEPTION: Van parking spaces shall be permitted to be 9C minimum in width where the adjacent access aisle is 96" minimum in width. B. Parking access aisles shall be 60" wide. Van accessible access aisles shall be 96" wide. C. Surface slope shall not exceed 1:48 in all directions (Note : no built up curb ramp may be located in an accessible parking access aisle.) ANSI/ICC A117.1 603.2 - CLEARANCES A. Lavatories shall be mounted with the rim or counter surface no higher than 34 „ Height: The uppecase letter r shall be used to determine the allowable height of all A. The accessible fixtures and controls required shall be on an accessible route. An characters of a font and shall be a minimum of r and 2" maximum. unobstructed turning space complying with 304 shall be provided within an accessible above the finished floor. 1. Lavatories shall extend 17" minimum from the wall. toilet room. The clear floor space at fixtures and controls, the accessible route, and EXCEPTION: Where separate tactile and visual characters with the some information are the turning space may overlap, however, the only turning space provided shall not be 2. Clearance of 27" minimum shall be provided from the finished floor to bottom „ „ 9 P Y P Y 9 P P provided, the height of the tactile upper case letter r shall be permitted to be r located within a stall. of apron. minimum. 3. Knee clearance of 27" high minimum shall extend 8" minimum under the edge ANSI/[CC A117.1 603.3 & 606 - LAVATORIES AND MIRRORS ANSI of the lavatory, , andeep minimum. 30" wide minimum, 19" dini / „ ANSI/ICC A117.1 703.2.5 -CHARACTER WIDTH A. If lavatories and mirrors are provided, then at least one of each shall comply 4. Toe clearance of 9 minimum shall be provided for the full depth of the A. Width: The uppercase letter "T shall be used to determine the allowable width of all with 603.3 & 606. Accessible lavatories and mirrors shall not be located within toilet lavatory. characters of a font, and shall be 55% min. and 110% max. of the height of the stalls unless other accessible lavatories and mirrors are provided in the toilet room. uppercase "r of the font. ANSI/ICC A117.1 606 -DEPTH ANSI/ICC A117.1 603.3 - MIRRORS (REFERENCE DETAIL) A. Each sink shall be a maximum of 6-1/2" deep. OVERHEAD SIGNS A. Mirrors shall be mounted with the bottom edge of the reflecting surface 4T - A. Characters and numbers on overhead signs shall be sized according to the viewing maximum A.F.F. Mirrors not located above lavatoreis, sinks or counters shall be t distance from which they are to be read. mounted with the bottom edge of the reflecting surface 35" maximum above the t I 1. For signs higher than 7T A.F.F., character size shall be T minimum plus r per floor. o 'E foot of viewing distance above 15 feet. o c 7" Mi \ 2. The minimum height is measured using an upper case letter "r. 5 _ _ 3. Lower case letters are permitted. 604 WATER CLOSET$ TOILET COMPARi IENTS 0 M rclear 1 ANSI/ICC A117.1 703.3-703.5 - RAISED CHARACTERS, BRAILLE, & PICTOGRAMS floor o v space A. Raised characters shall comply with section 703.3 and shall be duplicated in braille ANSI/ICC A117.1 604.3 - CLEARANCES 9 l." M L_ _ - complying with section 703.4. A Clear floor space for water closets not in stalls shall be provided as follows:qi 'rn N N 19" a B. Letter and numerals shall be raised 1/32", upper case, sans serif and shall be Clearance around a water closet shall be 60" minimum in width, measured accompanied by grade 2 Braille. perpendicular from the sidewall. Clearance around the water closet shall be 56" ax. 48" Min. 1. Raised character height: ' minimum to 3" plus " per foot of viewing distance minimum in depth, measured perpendicular from the rear wall. (Reference Detail)J2gfgil Detai above 21 feet. B. No door swings are allowed in clear floor area. 2. Braille shall be contracted (grade 2); shall be located below title corresponding text. 3. Pictograms shall be accompanied by the equivalent verbal description placed 56" MIN. 11 4T MIN. L, I 12" MAX 1 _ IN I •d- b N c0 ID L _ _ n ltd ANSI/ICC A117.1 604.4 - HEIGHT (REFERENCE DETAIL) A. The height to the top of the toilet seat shall be 17" - 1T above floor. 1. Seats shall not be sprung to return to a lifted position. ANSI ICC A17 4 604 5 GRAB BARS REFERENCE DETAIL / - ( S) A. For water closets not located in toilet stalls, the following grab bars shall be provided, 33" - 36" above the finish floor. 1. Side wall horizontal: 42" in length minimum, 12" max from rear wall, extending " 54 min. from rear wall 2. Side wall vertical: 18" in length minimum, bottom of bar located 3T min/41" max. above the floor, centerline V min/41" max from rear wall 3. Back wall: 36" in length minimum, extend from centerline of water closet 12" min. on side closest to the wall, 24" min. on transfer side. ANSI/ICC A117.1 604.6 - FLUSH CONTROLS A. Flush controls shall be hand operated or automatic, and located on the open side of the water closet. Hand operated flush controls shall comply with Section 309. IBC with WA STATE AMENDMENTS 1101.2.8 - FLUSH CONTROLS A. Hand operated flush controls shall comply with Section 309, except the maximum height above the floor shall be 44". ANSI/ICC A117,1 606.6 - EXPOSED PIPES AND SURFACES directly below the pictogram. A. Hot / cold water and drain pipes under lavatories shall be insulated or otherwise 4. The border dimension of the pictogram shall be 6" min. in height. configured to protect against contact. B. There shall be no sharp or abrasive surfaces under lavatories. ANSI/ICC A117.1 703.3.12 - FINISH AND CONTRAST A. Characters and their background shall have a nonglare finish. Characters shall ANSVICC A117.1 606.4 - FAUCETS contrast with their background, with either light characters on a dark background, or A. Controls shall be operable with one hand and shall not require tight grasping, dark characters on a light background. pinching, or twisting of the wrist. B. The force required to activate controls shall be no greater than 5 lb. ANSI ICC A117.1 703.3.10 & 703.3.11 - MOUNTING LOCATION AND HEIGHT REFERENCE DETAIL / ( ) C. Lever -operated, push -type, and electronically controlled mechanisms are examples of A. Characters and their background shall have a nonglare finish. Characters shall acceptable designs. contrast with their background, with either light characters on a dark background, or D. If self -closing valves are used the faucet shall remain open for 10 seconds dark characters on a light background. minimum. B. Where a tactile sign is mounted next to a door, it shall be placed to the latch side of the door wherever possible. Where a tactile sign is placed adjacent a double door, the sign shall be to the right hand door. If there is no wall space to the right, ANSI/ICC A117.1 603.6 - OPERABLE PARTS signs shall be placed on the nearest adjacent wall. Exception: Door mounted signs A. Operable parts on towel dispensers and hand dryers shall comply with Table below. shall be permitted on the push side on the doors with closers and without hold open devices. C. Raised characters shall be 4T minimum above the floor, measured to the baseline of the lowest raised character and 60" maximum above the floor, measured to the Maximum 0.5 2 5 6' 9' I" Reach Depth Maximum Ogg 4C 4f 4d 39' 34 Reach Height baseline of the highest raised character. D. Mounting location for such signage shall be so that a person may approach within 3" of signage without encountering protruding objects or standing within the swing of a door. IBC with WA STATE AMENDMENTS 1101.2.9 - INTERNATIONAL SYMBOL OF ACCESSIBILITY A. Where the International Symbol of Accessibility is required, it shall be proportioned complying with ANSI/ICC A117.1 Figure 703.6.3.1. All interior and exterior signs depicting the International Symbol of Accessibility shall be white on a blue background. ANSVICC A117.1 905.2 - CLEAR FLOOR SPACE A clear floor space complying with Section 305 shall be provided. ANSI/ICC A117.1 905.3 - HEIGHT Accessible storage elements shall comply with at least one of the reach ranges specified in Section 308. ANSI/ICC A117.1 905.4 - OPERABLE PARTS Operable parts of storage facilities shall comply with Section 309. . -, : . rp ` u` Habitat 1 for Humanity' 2505 Third Avenue Suite 324 Seattle, WA 98121 206.720.7001 phone 206.720.2949 fax www.craftarchitects.com -- CONSULTANT 7052 ____ REGISTERED ARCHITECT -KAT N M. CRAFT STATE OF WASHINGTC Submittals/Revisions: EAA)0t4'C'E EFOCif OCT ILE)JIVIla EXPIRE' " " I I 'nuls, O... wto Sheet Title: ACCESSIBILITY GUIDELINES .Yco, s V._ RECEIVED CITY OF TUKWIL A Date: 09.130.115 OCT 0 5 2015 Design: PE PERMIT CENTER Drawn: TL Project No: 15-096 THIS SHEET IS PROVIDED FOR YOUR CONVENIENCE. IT CONTAINS SELECTIONS FROM THE CURRENT ACCESSIBILITY REFERENCED STANDARDS (2012 IBC CHAPTER 11 WITH WA STATE AMENDMENTS AND ANSI/ICC A117.1), BUT IS NOT INTENDED TO BE A COMPLETE OR EXHAUSTIVE COPY OF THE CURRENT ACCESSIBILITY STANDARDS. Vvi- I I\IUI I I UI\MF I /ir\UnI I LU 13 LU I J DEMOLITION GENERAL NOTES: 1. ALL EXISTING BUILDING COLUMNS, EXTERIOR WALLS AND STRUCTURAL MEMBERS TO REMAIN, UON. PROJECT SPECIFIC DEMOLITION INTENT IS DEFINED AS: 1.1. DOORS, DOOR FRAMES & DOOR CASING TO BE REPLACED 1.2. DOOR HARDWARE TO BE REPLACED 1.3. LIGHT FIXTURES TO BE REPLACED 1.4. SUSPENDED CEILING GRID AND PANELS TO REMAIN 1.5. GWB CEILING TO REMAIN 2. CONTRACTORS SHALL BE RESPONSIBLE FOR PATCHING AND/OR REPAIRING ANY DAMAGE CAUSED BY HIM OR HIS SUBCONTRACTORS TO ALL SURFACES AFFECTED BY DEMOLITION. REFINISH TO MATCH ADJACENT FINISH, OR AS NOTED HEREIN. 3. WHERE INTERIOR PARTITIONS, COLUMN FURRING, FIXTURES, CABINETRY, DOORS AND DOOR FRAMES, ARE SCHEDULED FOR REMOVAL, DISPOSE OF ALL DEBRIS AND PATCH FLOOR AND WALLS AS REQUIRED. PREPARE SURFACES FOR NEW FINISHES UON TYPICAL THROUGHOUT ENTIRE SPACE. 4. IN AREAS WHERE CEILING SYSTEM IS SCHEDULED FOR REMOVAL, DISPOSE OF ALL DEBRIS AND PATCH WALLS AS REQUIRED. TYPICAL THROUGHOUT ENTIRE SPACE. 5. OBTAIN DEMOLITION PERMITS AND INCLUDE ALL COSTS OF SAME IN CONTRACT PRICE. 6. FURNISH ALL LABOR AND MATERIALS/EQUIPMENT TO COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED. CONTRACTOR IS RESPONSIBLE FOR DISPOSAL OF ALL DEBRIS. 7. CONTRACTOR SHALL KEEP CONSTRUCTION AREA FREE OF DUST AND DEBRIS FOR THE DURATION OF CONSTRUCTION. 8. IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL, CLARIFY THE POINT IN QUESTION WITH DESIGNER BEFORE PROCEEDING. 9. IN PARTITIONS TO BE REMOVED, REMOVE AND CAP ALL OUTLETS, SWITCHES, WIRES, THERMOSTATS, ETC., TO THEIR SOURCE. 10. REMOVE ALL ABANDONED ELECTRICAL CONDUIT, CABLING BACKBOARD AND EQUIPMENT, TYPICAL THROUGHOUT ENTIRE SPACE. 11. AT COMPLETION OF DEMOLITION WORK, THE CONSTRUCTION AREA(S) SHALL BE LEFT IN "BROOM CLEAN" CONDITION. ALL DEBRIS AND MISCELLANEOUS MATERIAL SHALL BE REMOVED. 12. IN ADDITION TO SPECIFIC DEMOLITION SCOPE IDENTIFIED, PERFORM MISCELLANEOUS DEMOLITION AS REQUIRED TO SUPPORT NEW CONSTRUCTION. COORDINATE EXTENT OF DEMOLITION WITH NEW WORK INDICATED ON THE FOLLOWING DRAWINGS. 13. NO EXISTING SMOKE DETECTOR, PUBLIC ADDRESS SPEAKER, FIRE ALARM BOX OR SIMILAR DEVICE, INCLUDING THE ASSOCIATED WIRING SHALL BE DAMAGED DURING DEMOLITION AND SUBSEQUENT CONSTRUCTION. RELOCATION OF SMOKE DETECTORS, PUBLIC ADDRESS SPEAKERS AND FIRE ALARM EQUIPMENT, NECESSITATED BY NEW CONSTRUCTION, SHALL BE ACCOMPLISHED AS A FIRST PRIORITY, AND PER THE PLANS, NO ACTIVE SMOKE DETECTOR SHALL BE PERMANENTLY COVERED OR OTHERWISE REMOVED OR USED FOR OTHER THAN ITS INTENDED PURPOSE. REMOVE TEMPORARY COVERS DAILY. 14. REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES, AND CONDUIT PERTAINING TO DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED WITH OWNER/TENANT AND DESIGNER. ONLY REUSED CABLING MAY REMAIN IN THE PLENUM. ALL OTHER CABLING MUST BE REMOVED. DEMOLITION KEY NOTES O 1. EXISTING DOOR AND PARTITION TO BE REMOVED 2. EXISTING TELEPHONE EQUIPMENT AND BOARD TO BE REMOVED 04 /, N 2 DEMOLITION 19) (18 24'-0" 24'-0" n 24'-0" 24'-0" L 24'-0" L"i 24'-0" 13 711-SIT I I I IA& DED 20A 4 p Iw D p I p p p EXIT TRAVEL DISTANCE: 125'-9" p a a a a a a a a a a a i a a a a a a a a a a a a K a a a a a a a a a a a a a a a i a p 2 p TYP. TYP. p 11 TYP. r I- 11 -1 I-" -I -1 f I- __1p I- I- I- r II I I I I p I p p l I I I II I I I I p I I p I I p p I I I I I I I I p I I p I I p p I I I I I I I I p I p l I I I II I I I I p l i p I I p pi I I I I I I I p I 240) 1 PH. 60 A p I I I I I I I I II I I I I II p I I I I I I I I I I p I p I I p i - -J I I I I I I I I I I p I I I I I I I I p p I I p I as=aa I I I I I I I I I I I I I I I I I I p p EXIST p I I I I I I I I I I I I I I I I I p K 00 p I I I I I I I I BREAK R M I I p 107 I I I I I I I I I I I I I RECEIV NG p p _ 4 _ Abl a== p EXIST p MEN'S 106 I I Q p p EXIST p WOMEN'S p l 105 2 5 3p __ p 240V 1 p DRYER - P 1 60 ¢ p s p EXIST WASHER 'ED 20 OFFICE UTILITY 103 WASHER dED 20A 104 I J pI I _ p p p I EXIST p ENTRY p 101 p p p TRAVEL DISTANCE: 114'-S' p I r=aa=aa=aaa F EXIST p ulJ ELECTRICAL N EXIT 102 0 0 by F p L - DN EXIST p STAIR ENCLOSED III 120 N - 5p p R o II I II I I I I p I I_o CRAATE STORAGE RACK PERMIT REQUIRED I I p k storage fixtures over 5'-9" high shall be I I I I I M under the provisions of a separate storage rack I M g permit. All rack storage fixtures greater than I I I I J igh shall have the method of anchorage/bracingd by a professional engineer. Periodic special on is required in all cases during the anchorageks over 8-feet in height. Special inspectionments shall be specified or, the rack permit plan. p p I ► I I I I p I II I I I I II I I I I I I I I I p I p L_ J L_ -1 L_ ._1 L_ -1 L_ _j 240V 1 PH. 60 A p SALES ROOM p 110 p I I I I p 4 p p p I I I p I 2 p p p I I I p i p p p p mn TRAVEL DISTANCE: 191'-2" I 00 r p RW aaaaaaaaaaaA W a=aaaa =aaaaaaa aaaaaaaa p p 7 p EXISTING I EXIT s OPENING _ &_ 9 0 0 Lel 12 r 2 DN A2.2 RE ItWED FOR (CODE COMPLIANCE APPROVED OCT 13 2015 City of Tukwila BUILDING DIVISION FLOOR EGRESS PLAN 1 /8" = 1'-0" U C FBI GENERAL NOTES: 1. WHERE NEW FLOOR FINISHES AND/OR WALL BASE ARE SCHEDULED, PREPARE FLOORS AND WALLS TO RECEIVE NEW FINISH. CONCRETE SLAB TO RECEIVE NEW SEAL WHERE SAW -CUT AND PATCHED. PATCH AND PAINT ALL OFFICE <.. WALLS. TYPICAL THROUGHOUT. 2. FINISHES MATCH EXISTING.Habitat 3 ALL NEW TO BE WALL TYPE 1 UON, SEE SHEET A2.2 FOR for Humanityo 4. FOR ACCESSIBILITY COMPLIANCE REFER TO SHEET T1.2. 5. THERE SHALL BE NO EXPOSED PIPE, CONDUIT, DUCTS, VENTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED AND FINISHED, UNLESS OTHERWISE NOTED AS EXPOSED CONSTRUCTION ON THE DRAWING. 6. OFFSET STUDS, WHERE REQUIRED, SO THAT FINISHED PARTITION SURFACE WILL BE FLUSH, UNLESS OTHERWISE NOTED. PROVIDE FURRING AT EXISTING PARTITIONS AS REQUIRED TO INSTALL ELECTRICAL ITEMS AS INDICATED ON THE DRAWINGS. 7. FINISHED FACES OF NEW PARTITIONS PARALLEL TO EXISTING FRAMING SHALL ALIGN. 8. GC SHALL BE RESPONSIBLE FOR PROVIDING ALL BLOCKING FOR ALL WALL a r C h I t@ C t s AND CEILING MOUNTED ITEMS, INCLUDING HARDWARE, LIGHT FIXTURES, GRAB BARS, CASEWORK, AND ALL OWNER PROVIDED ITEMS. PROVIDE SHEET METAL 2505 Third Avenue REINFORCING (8" HORIZONTALLY MOUNTED STRIP OF 20 GA. GALVANIZED Suite 324 SHEET METAL) CONCEALED IN PARTITIONS WHERE WALL OR CEILING MOUNTED Seattle, WA 98121 ITEM IS INDICATED ON DRAWINGS. 9. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DESIGNER PRIOR TO MANUFACTURE OF ANY CASEWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS 206.720.7001 phone REQUIRING CUSTOM SHOP FABRICATED WORK. 206.720.2949 fax www.craftarchitects.com LEGEND: EXISTING PARTITION TO REMAIN 4er U 0 NEW PARTITION 39 8 j I p WALL MOUNTED DUPLEX OUTLET: DED OR HATCH = DEDICATED 20A = 20 AMP CIRCUIT WALL MOUNTED FOURPLEX RECEPTACLE OUTLET DED OR HATCH = DEDICATED 20A = 20 AMP CIRCUIT Z Q T = 12 HOUR TIMER I- WALL MOUNTED VOICE/DATA PORT - (2) VOICE/(2) DATA IN SINGLE GANG O J BOX, UON 10 I$ SPECIAL OUTLET PER FLOOR PLAN < EXIT d EXIT INTERNALLY ILLUMINATED EXIT SIGNAGE W/ BATTERY BACKUP PER co IBC SECTION 1011, CONFIRM OPERATION OF EXISTING. ADD NEW WHERE NOT EXISTING. ARROW = DIRECTION INDICATOR, IF REQUIRED ao 0 r TACTILE EXIT SIGN, ADJACENT TO DOOR PER 703/T1.2. ADD NEW WHERE NOT EXISTING. DIRECTION OF TRAVEL PATH OF EGRESS START POINT COMMON PATH OF TRAVEL TERMINATION POINT CONSULTANT KEY NOTES: O 1. EXISTING STOREFRONT SYSTEM AND ACCESSIBLE ENTRY DOOR 2. EXISTING MOP SINK 3. EXISTING WATER HEATER 4. EXISTING CASEWORK AND SINK 5. NEW 4'X8'X3/4" TYPE 'X'/FIRE RESISTANT PLYWOOD BACKBOARD ON WALLS AS INDICATED, WITH FINISHED EDGES FOR TENANTS TELEPHONE AND SECURITY EQUIPMENT, TOP OF BACKBOARD MOUNTED AT CEILING, BOTTOM TO BE 26' AFF, MINIMUM. 6. LOCATION OF EXISTING ELECTRICAL TRANSFORMER AND PANELS 7. EXISTING DOCK LEVELER 8. OPEN EXISTING DOCK -HIGH OVERHEAD DOOR AND SECURE IN PLACE. INFILL WITH NEW CLEAR ANOD. 4-1/2" CENTER SET THERMALLY BROKEN ALUMINUM STOREFRONT IN EXISTING OPENING. GLAZING U FACTOR OF .40 AND SHGC OF .40 9. PERMANENT WASHER AND DRYER, PROVIDE IN -WALL DRAIN AND WATER CONNECTIONS 10. WASHER TESTING STATION, PROVIDE IN -WALL DRAIN AND WATER CONNECTIONS 11. RELOCATED OPEN METAL RACKING 3'-6" DEEP X 8'-0" HIGH X 8'-0" LONG. SEE STRUCTURAL CALCULATIONS PREPARED BY LUND OPSAHL STRUCTURAL ENGINEERS DATED 9/11/15 FOR BASE ATTACHMENT TO CONCRETE FLOOR SLAB, TYP. PIRED 12. EXISTING STAIRS, LANDING AND RAMP 13. EXISTING PARKING EX 14. EXISTING DRIVE -UP RAMP AJS Q1. 20 Sheet Title: FLOOR/EGRESS PLAN, DEMOLITION PLAN RECEIVED Date: 09.130.115 CITY OF TUMILA Design: PE OCT 0 5 205 Drawn: TL PERMIT CENTEF1.1 Project No: 15-096 Approved: KCR bh 1 UKAr I AKUH11 LU 15 1U 15 DOOR/RELITE SCHEDULE OPENINGS FRAMES DETAILS REMARKS NO. TYPE W x H THK MATL GL INSUL R nNG HDW FIN TYPE MATL FIN HD JAMB SILL 104 F PAIR T4 X 7'-0" 1 3/4" WD - YES - A CLEAR 1 WD* PAINT 7/A2.2 6/A2.2 5/A2.2 VERIFY AND MATCH EXIST DOOR HEIGHT AND TYPE AND FRAME TYPE DOOR SCHEDULE NOTES: 1. ALL DOOR HARDWARE SHALL BE FULLY ACCESSIBLE PER THE PROVISIONS OF ANSI A117.1 SECTION 404, AS SUMMARIZED ON T1.2. EXISTING HARDWARE IS ASSUMED TO BE ACCESSIBLE; LEVER STYLE HANDLE, CLEAR WIDTH, CLOSING SPEED, DOOR OPENING FORCE, ETC. GC TO REPLACE DOOR HARDWARE AS REQUIRED. 2. ALL DOORS TO BE READILY OPERABLE IN THE DIRECTION OF EGRESS TRAVEL WITHOUT THE USE OF A KEY OR SPECIAL EFFORT. 3. NEW DOORS (INTERIOR) TO BE BUILDING/OWNER STANDARD: SOLID CORE, WOOD, UNIFORM WHITE BIRCH, ROTARY CUT, NATURAL, CLEAR #00 FINISH. NEW INTERIOR DOOR FRAMES TO BE BUILDING/OWNER STANDARD: KNOCK DOWN (TIMELY, MITERED OR EQUIVALENT) STYLE, FACTORY FINISH, BLACK. 4. IG INDICATES INSULATED GLAZING, TYP. 5. TG INDICATES TEMPERED GLAZING, TYP. 6. TIG INDICATES TEMPERED, INSULATED GLAZING, TYP. 7. ALL EXTERIOR/BUILDING ENVELOPE AND INSULATED GLAZING SHALL BE CERTIFIED & LABELED WITH ITS MAX. U-FACTOR OF 0.38 & SOLAR HEAT GAIN, COEFFICIENT OF 0.40, PER WSEC SECTION C303.1.3 (RATING DETERMINED BY AN ACCREDITED, INDEPENDENT LABORATORY, LABELED AND CERTIFIED BY THE MANUFACTURER). 8. DOORS OPENING INTO SEMI -HEATED SPACE UNCONDITIONED SPACE OR TO THE EXTERIOR TO BE 0.37 MAX U-FACTOR. 9. GC TO COORDINATE WITH TENANT SUPPLIED AND INSTALLED SECURITY AND ALARM SYSTEM. DOOR HARDWARE NOTES: TYPE A: PASSAGE SET, FLUSH BOLT, SEALS AND DOOR BOTTOM 4- UUUM Hivu i Kim (L DOOR AND TRIM (L DOOR AND TRIM FLOOR FINISH MATL SAME ON BOTH SIDES OF OPENING RESILIENT FLOOR MATERIAL DOOR TRANSITION STRIP CPT REDUCER STRIP TO MATCH RUBBER BASE CARPET/CARPET TILE CONCRETE SLAB DOOR TRANSITION STRIP CPT REDUCER STRIP TO MATCH RUBBER BASE CARPET/CARPET TILE DOOR/RELITE TYPES PER DOOR SCHEDULE J 0 w U V) 0 0 0 w F (FLUSH) SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" FRAME TYPES c V a TYPE AS SCHEDULED RUNNER CASING 1 TO MATCH JAMB JAMB STOP DOOR AS SCHEDULED TYPE AS SCHEDULED 1 CASING I TO MATCH EXISTING PFR grHFnl11 F V: d d d HEAD )WINDOW 1 1 /2"=1'-0" d ° Q d a z _ a JAMB o R STOP R AS SCHEDULED CARPET OVER PAD. IF CARPET TILE (1 /4") OR WALK -OFF MAT (5/8" ) - FLOAT FLOOR AS REQUIRED FOR LEVEL TRANSITION - REFER ALSO TO GENERAL NOTES DOOR 3/8"xi-1/2" BRUSHED ALUM. ANGLE SECURED TO SLAB TILE CONCRETE SLAB OR RESILIENT FLOOR MATERIAL DOOR TRANSITION STRIP TILE CONC WALL BACKER ROD AND SEALANT BOTH SIDES DIM POINT KAWNEER 451-T OR EQUAL STOREFRONT SYSTEM TYP `1" TYP (: )WINDOW JAMB (13 1 SILL/FLOOR TRANSITION O WINDOW SILL GLAZING PER ELEVATIONS BACKER ROD AND SEALANT BOTH SIDES KAWNEER 451-T OR EQUAL STOREFRONT SYSTEM GLAZING 1" INSULATED GLASS, TYP. BACKER ROD AND SEALANT BOTH SIDES CONC TILT -UP WALL PANEL GLAZING PER ELEVATIONS KAWNEER 451-T OR EQUAL STOREFRONT SYSTEM DIM POINT SUBSILL AND END DAM SET IN BED OF MASTIC CONC TILT -UP WALL PANEL R-30 CONTINUOUS BATT INSULATION 5/8" 'TYPE X' GWB, FIRETAPED ONLY ON WAREHOUSE SIDE - FINISH AS SCHEDULED ON OFFICE SIDE, OVER 3-5/8" x 1-5/8", 20 GA MTL. STUD FRAMING ® 24" OC MAX 1/2" DEFLECTION (L240) W/ R-13 BATT INSULATION W/ R10 CONTINUOUS RIGID INSULATION AND FSK-25 VAPOR BARRIER WHERE EXPOSED AND AT WARM WALLS 6" 20 GA CEILING JOISTS @ 24" OC - MAX 1/2" DEFLECTION (L/240) CEILING PER PLAN METAL STUD RUNNER ATTACHED TO EXISTING CONC. SLAB W/ 5/32" DIA LOW -VELOCITY POWER -DRIVEN FASTENER W/ 1 1/4" PENETRATION MIN, 18" OC UTILITY/WHSE PARTITION N ALL GLAZING SHALL BE CERTIFIED AND LABELED WITH MAX U-FACTOR OF 0.40 & SHGC OF .40 8,-0" 3 EQ. IG IG IG 7 `- \ A2.2\ ZS IG IG IG X ! w TIG TIG TIG w /11NFILL ELEVATION REFLECTED CEILING PLAN 1'-0" CEILING GENERAL NOTES PER: 2012 INTERNATIONAL BUILDING CODE (IBC) SECTIONS 803.9, 808 AND 1613.1, AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) C635 AND ASTM C636 REFERENCED IN IBC 808). AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) 7-10 SECTION 13.5.6 (REFERENCED IN IBC 1613.1). GENERAL RECOMMENDATIONS `' ` Habitat A. REFERENCED SOURCES PER HIERARCHY. 2012 INTERNATIONAL BUILDING CODE (IBC), AMERICAN for Humanity' SOCIETY OF CIVIL ENGINEERS (ASCE 7-10), AMERICAN SOCIETY OF TESTING MATERIALS (ASTM C 635, ASTM C 636, ASTM E 580/E 580M), AND CEILINGS AND INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION (CISCA). B. PARTITIONS THAT ARE TIED TO THE CEILING AND ALL PARTITIONS GREATER THAN 6 FEET IN HEIGHT SHALL BE LATERALLY BRACED TO THE STRUCTURE. BRACING SHALL BE INDEPENDENT OF THE CEILING SPLAY BRACING SYSTEM. SOURCE: ASCE 7-10 SECTION 13.5.8.1 C. D. ALL MAIN BEAMS ARE TO BE HEAVY DUTY (HD). SOURCE: ASTM E580 SECTION 5.1.1 CEILINGS LESS THAN OR EQUAL TO 144 FT2 AND SURROUNDED BY WALLS CONNECTED TO THE STRUCTURE ABOVE ARE EXEMPT FROM THE SEISMIC DESIGN REQUIREMENTS. SOURCE ASTM E580 SECTION 1.4 Rff E. THESE RECOMMENDATIONS ARE INTENDED FOR SUSPENDED CEILINGS AND RELATED COMPONENTS IN AREAS THAT REQUIRE RESISTANCE TO THE EFFECTS OF EARTHQUAKE MOTIONS. SOURCE: ASTM E580 - C I t @ C . S SECTION 3.2 F. ALL WIRE TIES ARE TO BE THREE TIGHT TURNS AROUND ITSELF WITHIN THREE INCHES. TWELVE GAGE G. HANGER WIRE SPACED 4 FOOT ON CENTER. SOURCE: ASTM C636 SECTION 2.3.4 CHANGES IN CEILING PLANES WILL REQUIRE POSITIVE BRACING. SOURCE: ASTM E580 SEC11ON 5.2.8.6 2505 Third Avenue LATERAL FORCE BRACING Suite 324 H. CEILINGS CONSTRUCTED OF SCREW -OR -NAIL -ATTACHED GYPSUM BOARD ON ONE LEVEL THAT ARE Seattle, WA 98121 SURROUNDED BY AND CONNECTED TO WALLS OR SOFFITS THAT ARE LATERALLY BRACED TO THE STRUCTURE ABOVE ARE EXEMPT FROM SEISMIC DESIGN REQUIREMENTS. SOURCE: ASCE 7-10 SECTION 13.5.6.2.2 EXCEPTION 2, ASTM E580 SECTION 1.7 206.720.7001 phone I. CEILING AREAS OF 1000 FT2 OR LESS SHALL BE EXEMPT FROM LATER FORCE BRACING 206.720.2949 fax REQUIREMENTS. SOURCE: ASTM E580 SECTION 1.6 J. LATERAL FORCE BRACING SHALL BE 12 FEET ON CENTER (MAXIMUM) AND BEGIN NO FARTHER THAN 6 FEET FROM WALLS. SOURCE: ASTM E580 SECTION 5.2.8.2 www.craftarchitects.com K. SEISMIC SPLAY WIRES ARE TO BE FOUR 12 GAGE WIRES ATTACHED TO THE MAIN BEAM. WIRES ARE ARRAYED 90' FROM EACH OTHER AND AT AN ANGLE NOT EXCEEDING 45' FROM THE PLANE OF THE CEILING. SOURCE: ASTM E580 SECTION 5.2.8.2 L. SEISMIC SPLAY WIRES SHALL BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL DESIGN LOAD, WITH A SAFETY FACTOR OF 2, WHICHEVER IS GREATER. SOURCE: CISCA ZONES 3-4 M. SPLAY WIRES ARE TO BE WITHIN 2 INCHES OF THE CONNECTION OF THE VERTICAL STRUT TO SUSPENDED CEILING. SOURCE: ASTM E580 SECTION 5.2.8.2 N. RIGID BRACING MAY BE USED IN LIEU OF SPLAY WIRES. SOURCE: ASTM E580 SECTION 5.2.8.4 0. VERTICAL STRUTS MUST BE POSITIVELY ATTACHED TO THE SUSPENSION SYSTEMS AND THE STRUCTURE ABOVE. SOURCE: ASTM E580 SECTION 5.2.8.2 F P. WALL THE VERTICAL STRUT MAY BE EMT CONDUIT, METAL STUDS OR A PROPRIETARY COMPRESSION POST. MOLDINGS Q. WALL MOLDINGS (PERIMETER CLOSURE ANGLES) ARE REQUIRED TO HAVE A HORIZONTAL FLANGE 2 W 7% INCHES WIDE. ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE WALL MOLDING, THE OTHER END SHALL HAVE A % INCH CLEARANCE FROM THE WALL AND FREE TO SLIDE. SOURCE: v ASTM E580 SECTION 5.2.2, SECTION 5.2.3 SPREADER BARS R. TERMINAL ENDS OF MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED TOGETHER OR HAVE SOME OTHER APPROVED MEANS TO PREVENT THEIR SPREADING. STABILIZER BARS, CROSS TEES OR OTHER MEANS TO PREVENT SPREADING SHALL OCCUR WITHIN 8 IN. OF EACH WALL. SOURCE: ASTM E580 S. SECTION 5.2.4 SPREADER BARS ARE NOT REQUIRED AT PERIMETERS WHERE RUNNERS ARE ATTACHED DIRECTLY TO CLOSURE ANGLES. SPREADER BARS ARE NOT REQUIRED IF A 90 DEGREE INTERSECTING CROSS OR MAIN IS WITHIN 8 INCHES OF THE PERIMETER WALL HANGER (SUSPENSION) WIRES a: T. HANGER AND PERIMETER WIRES MUST BE PLUMB WITHIN 1 IN 6 UNLESS (FIGURE 5A) COUNTER U. SLOPING WIRES ARE PROVIDED. SOURCE: ASTM C636 SECTION 2.1.4 HANGER WIRES SHALL BE 12 GAGE AND SPACED 4 FEET ON CENTER OR 10 GAGE SPACED 5 FEET _,,^ 0 V. ON CENTER. SOURCE: ASTM C636 SECTION 2.1 ANY CONNECTION DEVICE AT THE SUPPORTING CONSTRUCTION SHALL BE CAPABLE OF CARRYING NOT W. LESS THAN 100 POUNDS. SOURCE: CISCA ZONES 3-4 TERMINAL ENDS OF EACH MAIN BEAM AND CROSS TEE MUST BE SUPPORTED WITHIN 8 INCHES OF EACH WALL WITH A PERIMETER WIRE. SOURCE: ASTM E580 SECTION 5.2.6 X. WIRES SHALL NOT ATTACH TO OR BEND AROUND INTERFERING MATERIAL OR EQUIPMENT. A TRAPEZE OR EQUIVALENT DEVICE SHALL BE USED WHERE OBSTRUCTIONS PRECLUDE DIRECT SUSPENSION. LO TRAPEZE SUSPENSIONS SHALL BE SIZED TO RESIST THE DEAD LOAD AND LATERAL FORCES 00 APPROPRIATE FOR THE SEISMIC CATEGORY. SOURCE: ASTM E580 SECTION 5.2.7.4 M ELECTRICAL FIXTURES Y. LIGHT FIXTURES WEIGHING LESS THAN 10 POUNDS SHALL HAVE ONE 12 GAGE HANGER WIRE CONNECTED FROM THE FIXTURE TO THE STRUCTURE ABOVE. THIS WIRE MAY BE SLACK. SOURCE: ASTM E580 SECTION 5.3.4 Z. LIGHT FIXTURES WEIGHING MORE THAN 10 POUNDS AND LESS THAN 56 LBS SHALL HAVE TWO 12 GAGE WIRES ATTACHED AT OPPOSING CORNERS OF THE LIGHT FIXTURE TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. SOURCE: ASTM E580 SECTION 5.3.5 AA. LIGHT FIXTURES WEIGHING MORE THAN 56 LBS. SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS. SOURCE: ASTM E580 SECTION 5.3.6 AB. PENDANT MOUNTED FIXTURES SHALL BE DIRECTLY SUPPORTED FROM THE STRUCTURE ABOVE USING A 9 GAGE WIRE OR AN APPROVED ALTERNATE SUPPORT WITHOUT USING THE CEILING SUSPENSION SYSTEM FOR DIRECT SUPPORT. SOURCE: ASTM E580 SECTION 5.3.7 CONSULTANT AC. TANDEM FIXTURES MAY UTILIZE COMMON WIRES. MECHANICAL SERVICES AD. TERMINALS OR SERVICES WEIGHING LESS THAN 20 LBS. SHALL BE POSITIVELY ATTACHED TO THE CEILING SUSPENSION MAIN RUNNERS OR TO CROSS RUNNERS THAT HAVE THE SAME CARRYING CAPACITY AS THE MAIN RUNNERS. SOURCE: ASTM E580 SECTION 5.4.1 AE. TERMINALS OR SERVICES WEIGHING 20 LBS. BUT NOT MORE THAN 56 LBS. SHALL HAVE, IN ADDITION TO 5.4.1. TWO 12 GAGE WIRES CONNECTING THEM TO THE CEILING SYSTEM HANGERS OR THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. SOURCE: ASTM E580 SECTION 5.4.2 AF. TERMINALS OR SERVICES WEIGHING MORE THAN 56 LBS. SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS. SOURCE: ASTM E580 SECTION 5.4.3 SEISMIC SEPARATION JOINTS AG. FOR CEILING AREAS EXCEEDING 2,500 SQUARE FEET, A SEISMIC SEPARATION JOINT OR FULL HEIGHT WALL PARTITION THAT BREAKS THE CEILING SHALL BE PROVIDED UNLESS ANALYSES ARE PERFORMED OF THE CEILINGS BRACING SYSTEM, CLOSURE ANGLES AND PENETRATIONS TO PROVIDE SUFFICIENT CLEARANCE. SOURCE: ASCE 7-10 SECTION 13.5.6.2.2 B SPRINKLERS AH. FOR CEILINGS WITHOUT RIGID BRACING, SPRINKLER HEAD PENETRATIONS SHALL HAVE A 2 INCH OVERSIZE RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FREE MOVEMENT OF AT 7052 LEAST 1 INCH IN ALL HORIZONTAL DIRECTIONS. FLEXIBLE HEAD DESIGN THAT CAN ACCOMMODATE 1 INCH FREE MOVEMENT SHALL BE PERMITTED AS AN ALTERNATE. SOURCE: ASTM E580 SECTION VARCEGISTERED HITECT 5.2.8.5 LEGEND' YWM HI AFT STATE 0 WAS GT N EXISTING PARTITION TO REMAIN Submittals/Revisions: PARTITION / ELEMENT TO BE DEMOLISHED NEW PARTITION 1X4 SURFACE MOUNTED FLUORESCENT FIXTURE W/ WRAP AROUND ACRYLIC LENS GWB GYPSUM BOARD CEILING CEILING KEY NOTES: O 1. LIGHT CENTERED IN ROOM, BOTH DIRECTIONS 2. INSTALL NEW 5/8" GWB CEILING IN UTILITY ROOM. Sheet Title: REFLECTED CEILING PLAN MATCH EXISTING CEILING HEIGHT Kl--V —VVED FOR ICOOE COMPLIANCE APPROVED OCT 13 2015 City of Tukwila BUILDING DIVISION DOOR SCHEDULE & PARTITION TYPES RECEIVED CITY OF TUMILA Date: 09.130.115 OCT 0 5 2015 Design: PE PERMIT CENT+ EP' Drawn: TL 15-096 X P..''! I E roved: KCR 120 Building No: