Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D15-0264 - HABITAT FOR HUMANITY - STORAGE RACKS
HABITAT FOR HUMANITY 1185 ANDOVER PARK W EXPIRED 07/05/16 D15-0264 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 3523049093 Permit Number: D15-0264 Address: 1185 ANDOVER PARK W Issue Date: 1/7/2016 Permit Expires On: 7/5/2016 Project Name: HABITAT FOR HUMANITY Owner: Name: ICON OWNER POOL 1 WEST LLC Address: 2 N RIVERSIDE STE 2350, CHICAGO, WA, 60606 Contact Person: Name: PAUL ENGERT Phone: (206) 720-7001 Address: 2505 THIRD AVE SUITE 324, SEATTLE, WA, 98121 Contractor: Name: WALSH CONSTRUCTION CO II LLC Phone: (312) 563-5400 Address: 929 W ADAMS ST ATTN: RYAN CULL, CHICAGO, IL, 60607 License No: WALSHCC907PR Expiration Date: 10/18/2016 Lender: Name: HABITAT FOR HUMANITY Address: 560 NATHES SE, RENTON, WA, 98057 DESCRIPTION OF WORK: INSTALL 107 BAYS OF SHELVING, 2 BAYS OF CANTILEVER RACKS AND 1 BAY OF HANGAR RACKING FOR TRIM Project Valuation: $1,500.00 Fees Collected: $188.10 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: Occupancy per IBC: Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Chan nelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: l )Ia I. - ��j Date: ` I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree �tootthe conditions attached to this permit. Signature: U Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 10: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 11: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC906.5) 12: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 14: Maintain fire extinguisher coverage throughout. 17: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 18: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 19: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 20: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 15: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUKWILA Community Development Department Public Works Department • Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.Rov Building Permit No. Project No. Date Application Accepted: Date Application Expires: CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 3523049093 Site Address: 1185 ANDOVER PARK WEST Tenant Name: HABITAT FOR HUMANITY PROPERTY OWNER Name: KIDDER MATHEWS Address: 631 STRANDER BLVD., SUITE 6 City: TUKWILA State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: PUAL ENGERT Address: 2505 THIRD AVENUE, SUITE 324 City: SEATTLE State: WA Zip: 98121 Phone: (206) 720-7001 Fax: (206) 720-2949 Email: pAUL@CRAFTARCHITECTS.COM GENERAL CONTRACTOR INFORMATION Company Name: WALSH PACIFIC Address: 16400 SOUTHCENTER PKWY, STE 501 City: SEATTLE State: WA Zip: 98188 Phone: (206) 394-7304 Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Suite Number: Floor: New Tenant: Q .....Yes ❑ ..No ARCHITECT OF RECORD Company Name: CRAFT ARCHITECTS Architect Name: CATHY M. CRAFT Address: 2505 THIRD AVENUE, SUITE 324 City: SEATTLE State: WA Zip: 98121 Phone: (206) 720-7001 Fax: (206) 720-2949 Email: pAUL@CRAFTARCHITECTS.COM ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: 11,4 iLwv ` Address: I . City: N State: �� Zip: q K\AppliadionsTorms-Applications On Line\2011 ApplicationsTermit Application Revised - 8-9-I l.docx Revised: August 2011 Page 1 of 4 bh BUILDING PERMIT INFORMATION — 1.06-431-3670 Valuation of Project (contractor's bid price): e Describe the scope of work (please provide detailed intormation): Existing Building Valuation: or WI-K �nS iv'� Will there be new rack storage? m.....Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor Q� C�J (00 2° Floor Yd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? El ....... Yes Z....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ...... Sprinklers \—q/.. Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? "X ....... Yes No If `yes', attach list of materials and storage locations on a separate 8-112"x II "paper including quantities and Material Sa ery ata Sheets. SEPTIC SYSTEM ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsTonns-Applications On Line\2011 ApplicationsTermit Application Revised - 8-9-1 Ldocx Revised: August 2011 Page 2 of 4 bh PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Paul Engert Date: 10/01 /2015 Print Name: PAUL ENGERT Day Telephone: (206) 720-7001 Mailing Address: 2505 THIRD AVENUE, SUITE 324 SEATTLE WA 98121 City State Zip H:\Applications\Forms-Applications On Line\2011 ApplicaticnsWemut Application Revised - 8-9-11.docx Revised: August 2011 Page 4 of 4 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $188.10 D15-0264 Address: 1185 ANDOVER PARK W Apn: 3523049093 $188.10 DEVELOPMENT $182.70 PERMIT FEE R000.322.100.00.00 0.00 $108.00 PLAN CHECK FEE R000.345.830.00.00 0.00 $70.20 WASHINGTON STATE SURCHARGE 13640.237.114 0.00 $4.50 TECHNOLOGY FEE $5.40 TECHNOLOGY FEE TOTAL FE S PAID BY RECEIPT: R6396 R000.322.900.04.00 0.00 $5.40 $188.10 Date Paid: Monday, October 12, 2015 Paid By: CYDNIE HORWAT Pay Method: CREDIT CARD 802579 Printed: Monday, October 12, 2015 1:43 PM 1 of 1 �A' !� SYSTEMS INSPECTION RECORD 71 S - r, b 3. IReta1iin a copy with permit / 1 INSPECTION NUMBER fJ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ve J � ENQ .� ,aw Type of Inspection: rCl, 4 L- Address: Contact Person: Suite #: Special Instructions: Phone No.: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: • v t r i -P `L�4i`� - ,CA Opt 0i } a r' Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: Hrs.: ❑ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Lsining Aaaress Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORD D 15-- Q Z(o Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:-C Type of Inspection: Address: � Z SC Contact Person: Suite #: #A d Special Instructions: Phone No.: k"Approved per applicable codes. Corrections required prior to approval. l COMMENTS: f Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:{ _ 9Z�?P Date: 3Z-7a�, Hrs.: . —7 ❑ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORDS J Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 4A +,AT, Type of In pection: Address: j /A Contact Person: Suite #: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: �" �}✓ (-e C/ L1%4 ,v n )i16-, e Ao �. ,i I �2 4 �l�c+4,c L nn r r3 & t / iJe ,r Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: /; Date: (/4 1 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 STRUCTURAL CALCULATIONS 15-152-01 Habitat Shelving Tukwila, WA for Habitat for Humanity September 11, 2015 rECEVED CITY OF TUKWILA OCT 0 6 2015 PERMIT CENTER • 1201 First Avenue South, Suite 310 1 Seattle, Washington 98134 11 06- 02- 156 1 %www.o ahl.co i UND -- P`SAHL Design Criteria Project Location Habitat for Humanity Tukwila, WA Project Scope Provide structural calculations for anchorage of steel storage racks to concrete flooring for Habitat for Humanity. Design Codes 2012 IBC, ASCE 7-10, ANSI/RMI Design Loads Dead Load = 15 psf (Steel framing) Product Load = 50#/2ft (Toilets, lumber, etc.) Seismic Load = V = CSSDSWS Sps= 0.912 [Per USGS] R= 4 Braced Direction, 6 Unbraced Direction Cs= 0.228 Ip= 1.5 Ws= Option 1: 67% rated load at each level + weight of rack Option 2: 100% rated load at top level + weight of rack COPYRIGHT The calculations, sketches and notations contained herein are not a part of the Contract Documents and any seal upon these documents only represents that they were prepared under the supervision of Lund Opsahl LLC. These calculations, sketches and notations are only an instrument for the sole use of Lund Opsahl LLC and are not to be used by any other party. If copies are provided to Building Regulation Agencies they are for the purpose of showing general criteria used for design. Copyright © 2015 Lund Opsahl LLC, All Rights Reserved. Pn�ject tt43i—TAT FUR ItUM/}N.!Y SHC-I-t�W,5i, 5met Subject STEEL STODGE' P*C-"S CNent HFt} Page No. Desinner CA IQ, I %w:%..IundopsahLcom Tel:206.402.5156 $i75Ra��' RA�c...1cg A16 , V2'1 01 .01 qe 2" Ne„ 32A Liar g FzAG�-5�^2ot�lC,T J SOS/2j O!= SFFCLV.r/li(, V z C,TP Ws CS a � 1� r `i F isRgr�E� Ai 2EG�� iJi2g �7 L5 =022`� Li (NS 0r-f-7UN 1 : 6-% RA rep LpoS AT t 4CN- LEVCL.. -;- wErbtrr t�F t�rl c 9-77a ('20a�/L scwL) = 0. INK/cet,rL -rRzavrAev AE,U-q = q to" x Y2" --,;, T�x = 2e *-r Z W5 oprr&r.. I = 0,IVkfG.flieU 4 0.yz x/4EVEN Ws o.rrvit, I = 0. S41t K/Le%'CL WS owrrzv j = /:.66Z K A=' � C.�rS ,- } C FopcES %F GEN�'ERCxN1s< t �aS� S!jc'LF r _ Vt�x�X �t rrgect t ASTTAr FOR- sheet Z Subject Sr -:EL STOCt46 K+f-r—S Clem 14r A Page Na u2stoner CA S wvw.lundopsahi.com I Tel:206.4025156 /"f^T -rC, t (CiQNT CAAe(Cb) oprxu� � Yo�Ld,,, = 0.56g K Cum F 1 FI=(o,56s K)(#.$W E60. S44 L F � O.t)95 K Sti-- -t= 2 , F^ 0 t4olc t-tELF 3: F3 DV�'R i �>(zlyZ/VG 'fRA ,,,,,,, = ©. S(o8 L., F, 5 . = / .5 RcQ L/recl S `/ Tamx:/4/VS = MR > M-0 MvMEA-r Ht3oue FOXMT A /Via F (32-11� 4 F,(6W") -F t=3(46') �30.94 �.e�'♦ � A4 43LeGSJF. S O ifs k� icon OA,� (22 k-.fv/ti-z mvt , F,4n, rnr�t - Pnject HkBZT'r4r pot- Hu AA► TTV SiicLyXfy4. Shen 3 Subject S rEEL S'rog'466— ND Client 14 Page Na Designer �� sDate NHL a ►��� S www.lundopsahl.com I Tel:206.402.5156 014z c YOPTsaAIZ = 01'3 k Ft F3-0.2a8K- M 0 = 31.4 k'�JV, O PZon/ t Gott/ T SEE- FfrL. -.�p PRo&--Lc. Mti•EnrT G�.FDU� I kwiY., MAC r T-�_;, - CS AIII of (2-t# A^zl , 1�!Y / �+ ND Project VAA6rr4—1 FOK f4uv.A-ka!'y Slitt—VZN&, Fheet q 5 Gf, WrC-Lctrc(t R c. S Client Ft+ Page No, Cesig rer `A S 0at_�/ S I. v-.v.lunJopsahl.com I Tel:206.402.515F C-AArT-r L X.,CfZ. SZ-4tP►a,46E Ha.. n tvu.1 171 K$" k� fi 6 C,'I WS = 0,6-4 (3 L.tt C.S) ,M5 /4EL:) ;+ 3 t_c'vcL( cps #=)(5 v7.)`W v-f',' WS= 0,C2r, -I-vr4,L ` = 0.21 K OVtE"t2,TtJRA! �!/�G. C" v.2 t Mb = F, C-t-", t Fi(sar) t r3CD6t t MD - t-4.s K-Xp•, M V,= (0 , fit k y K6'�Z/ s-� 40- = I'-t.98 !c t�5 t s _'> iqnt,H.•,^_ -sarw� �' °"�t � (�P-+C.kc� pus;: c� RE4Lt C-Hoos,C : � Kw,Z< S c>L-r T-- - GS Ye `1 o IF, ('a Pnoi2q RAP--CTRr i:o x. NAM oo Mr/ 5 ka subj-ct SrcIEL 14AN-AiL �D Client (-iFt* Page Na HL Demwe, c s CateQ111l i www.lundopsahl.com I Tel:206.402.5156 5T-GICL 14 "6A-r— Rkc s ?rzo�vcr a_fl4z-�. = so`Y2 ,MZ 7zfI C. = 0.12-> gyp_ 1. 5 (nJs �0.6'* (r5O%gvrLY2-GE✓t1.s� f W'S o i.36l-. CTorAt) OVIE z rVwvr►JG Mo = (-Lot') 4 F2 MO 2 c.E�,�zs('$ �s ��6 t=1 ;��s�..� x 2 •ems F = 0.3 R W, ? Fz— s 0. 09, K MR = (0, 6rsk )OZ01) + (v,&gk 6q `!) Mp -gv•a K-=N, P,e,, St 6 i Chem 11 � � P.- N. Designer CAR S Dare i .v!w.lundopsahl.com I Tek 206.402.5156 ALL 3 TYPES of vAc-sr- S 'y'D uSg-; 411-Tt K V-Ttr— IR-D l 7 --Z G5 y&" o w/ 2" �iC �JU k•� R. of.T �ONt E�It� 57D� } w/ Z,•�MIJ�, 111 4. C ArrZ LU V C K ?,4- C.i� NAA✓941Z RAL C o+rti E.4,5YD J ,,,,/ zu G-a6t. ost"o Kk=k RO%-T 6-keE-A, Sztx. ) wlzw6?KR6C:b, L"Mm www.hilti.us Profis Anchor 2.6.0 Company: Page: 1 Specifier: Project: Habitat for Humanity Address: Sub -Project I Pos. No.: Phone I Fax: Date: 9/11/2015 E-Mail: Specifier's comments: Steel Storage Racks Anchorage 1 Input data Anchor type and diameter: Kwik Bolt TZ - CS 318 (2) �mp Effective embedment depth: hef,acl = 2.000 in., hnom = 2.313 in. Material: Carbon Steel Evaluation Service Report: ESR-1917 Issued 1 Valid: 5/1/2013 1 5/1/2015 Proof: Design method ACI 318-11 / Mech. Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.250 in. Anchor plate: Ix x ly x t = 2.000 in. x 2.000 in. x 0.250 in.; (Recommended plate thickness: not calculated Profile: no profile Base material: cracked concrete, 4000, fr' = 4000 psi; h = 5.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Geometry [in.] & Loading [lb, in.lb] CO Y-- ,�� - - - o W - X Input data and results must be checked for agreement with the epsting conditions and for plausibilityl PROMS Anchor (c) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan www.hilti.us Company: Specifier: Address: Phone I Fax: E-Mail: 2 Proof I Utilization (Governing Cases) Profis Anchor 2.6.0 Page: 2 Project: Habitat for Humanity Sub -Project I Pos. No.: Date: 9/11/2015 Design values [Ib] Utilization Loading Proof Load Capacity CW / j3v [%] Status Tension Pullout Strength 780 1866 42 / - OK Shear Pryout Strength 284 2129 - / 14 OK Loading ON Pv C Utilization pN,v [%] Status Combined tension and shear loads 0.418 0.133 5/3 27 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and Geared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the ebsting conditions and for plausibility! PROFIS Anchor (c) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan I HABITAT FOR HUMANITY 1185 ANDOVER PARK WEST ` TUKWILA, WA �i1�� tOlt UPDATED, 6115/te J LEGEND: EXISTING PARTITION TO RCMAIN NEW PARTITION KEY NOTES: Q 1. NEW 'GUARDRAIL/HANDRAIL, THIS SIDE 2. RESTRIPE ADA STALL/ACCESS AISLE; ADD WHEELSTOP AND SIGN 3, NEW TULL-HEIGHT PARTITION WITH (2) 10'x14' OPENINGS NO TH FLOOR PLAN H�[ ilutnflnl(y' City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 6/1/2016 PAUL ENGERT 2505 THIRD AVE SUITE 324 SEATTLE, WA 98121 RE: Permit No. D15-0264 HABITAT FOR HUMANITY 1185 ANDOVER PARK W Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/5/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/5/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley Permit Technician File No: D15-0264 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development November 05, 2015 PAUL ENGERT 2505 THIRD AVE SUITE 324 SEATTLE, WA 98121 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D15-0264 HABITAT FOR HUMANITY - 1185 ANDOVER PARK W Dear PAUL ENGERT, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 2406; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" to be stamped and signed. [Electronic copies shall not be approved.] (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Since this permit is apparently a rack installation permit, revise the scope of work to indicate so on the plan cover sheet. Only provide sheets and details consistent with the rack installation. 2. All engineer and architectural documents and each plan sheet shall have wet stamp and signatures. (Please see General Note above) FIRE DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments. • 1) Please provide a list of the types of commodities to be stored in the racks/shelving. 2) What will be the total storage height? 3) What is the existing fire sprinkler density? 4) What is the temperature rating of existing fire sprinkler heads in the storage area? 5) Are there existing smoke vents? If so, please show them on the drawing. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington. 98188 • Phone 206-431-3670 • Fax 206-431-3665 If you have any questions, I can be reached at (206)431-3655. Sincerely, c Bill Rambo Permit Technician File No. D15-0264 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 �ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0264 DATE: 11/23/15 PROJECT NAME: HABITAT FOR HUMANITY SITE ADDRESS: 1185 ANDVER PARK W Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 DEPARTMENTS: AT, Building Division Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: *A PRO Fire Prevention Revision # after Permit Issued Structural ❑ Planning Division ❑ Permit Coordinator ❑ DATE: 11/24/15 Structural Review Required ❑ DATE: DUE DATE: 12/22/15 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: c5*4W'� REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COOPD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D 15-0264 DATE: 10/06/15 PROJECT NAME: HABITAT FOR HUMANITY SITE ADDRESS: 1185 ANDOVER PARK W X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: A-T CDwZ D')-o-ls- AK Building Division 0 Fire Prevention Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 10/13/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/10/15 Approved ❑ Approved with Conditions ❑ Corrections Required Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only j CORRECTION LETTER MAILED: 1 Departments issued corrections: Bldg— Fire Ping ❑ PW ❑ Staff Initials: 12/18/2013 pAr City of Tukwila Department of Comlnimity Development 6300 Southunter Boulevard, Suite 4 100 Tukwila, Mwrliington 98188 Mime: M6-43 1-3670 Fax: 206-43 1 -3665 Website.- REVISION SUBMITTAL "I Revision submiltatv must.he submitted in person at the Permit Omiter. Revisions will not he accepted through the mail, fax, etc. Date: Plan Check/Permit Number: D 15 -0264 F-1 Response to IFIC0111111CtC 1,CITCI- 4' Response to Correction Letter P, Ej Revision # after Permit is Issued RKEWO ❑ Revision requested by a City Building Inspcoor or Plans Examiner C ffv 04; IIJKWILA NOV I Project Name: Habitat for 1-1. i-'SP444T '-',ENTER Project Address: 1185 Andover Park W Contact Person- cjI'4.4e— J2LpLDj!5,vL Phone Number: Surnmary of Revision: 1. , -. -1, 1 Sliect Number(s): I "Cloud" or highlight all areas qf revision hicludillf, dat I of' Received at the CIIV ON'Lkwila Permit Center bar: W----VW - - - - -- ---- ---------- ---------- - - - - E] Entered in TRAKi,r on oil IiIIc\rcVkk)II Submittll Creitedi 8-1.3-2004 Re% ised. WALSH CONSTRUCTION CO III T C Page I of 2 Home Lnicua en I? pariol Contact Safety 401*4 Washington State Department of 4J Labor & Industries WALSH CONSTRUCTION CO II LLC Owner or tradesperson Principals WALSH, SEAN, MANAGER Doing business as WALSH CONSTRUCTION CO II LLC WA UBI No. 603 050 702 Parent company WALSH CONSTRUCTION GROUP LLC License Search L&I �j, A-"L Ind(w Help Nly Secure L&I Claims & Insurance Workplace Rights Trades & Licensing 929 W ADAMS ST ATTN: RYAN CULL CHICAGO, IL60607 312-563-5400 Business type Limited Liability Company Governing persons WALSH CONSTRUCTION G SEAN C WALSH; Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. WALSHCC907PR Effective — expiration 10/1812010-10/18/2016 Bond ................ TRAVELERS CAS & SURETY CO $12,000.00 Bond account no. 100900200201037 Received by L&I Effective date 10/18/2010 10/15/2010 Expiration date Until Canceled Insurance ............................. Arch Insurance Co $1,000,000.00 Policy no. 41 PKG8901909 Received by L&I Effective date 06101 /2015 06/01 /2015 Expiration date 06/01 /2016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=603050702&LIC=WALSHCC907PR&SAW= 1/7/2016 ABBREVIATIONS V ANGLE FLUOR FLUORESCENT PS PAINT SYSTEM t CENTER LINE FM FACTORY MUTUAL PSF POUNDS PER SQUARE FOOT 0 DIAMETER OR ROUND FOC FACE OF CONCRETE PSI POUNDS PER SQUARE INCH # NUMBER OR POUND FOF FACE OF FINISH PT PRESSURE TREATED PENNY FOIC FURNISHED BY OWNER PTD PAPER TOWEL DISPENSER -L PERPENDICULAR INSTALLED BY CONTRACTOR PTD/R PAPER TOWEL DISPENSER tt PLATE F010 FURNISHED BY OWNER AND RECEPTACLE INSTALLED BY OWNER PTN PARTITION AB ANCHOR BOLT FOS FACE OF STUD PTR PAPER TOWEL RECEPTACLE AC ACOUSTICAL FS FULL SIZE PVMT PAVEMENT A/C AIR CONDITIONING FT FEET ACP ACOUSTICAL CEILING PANEL FTG FOOTING QT QUARRY TILE ACT ACOUSTICAL TILE FTIC FURNISHED BY TENANT ADH ADHESIVE INSTALLED BY CONTRACTOR R RISER ADJ ADJACENT FTIO FURNISHED BY TENANT RA RETURN AIR AF ACCESS FLOOR INSTALLED BY OWNER RAD RADIUS AFF AT/ABOVE FINISH FLOOR FURR FURRING R&S ROD & SHELF AHJ AUTHORITY HAVING JURISDICTION PUT FUTURE RB RESILIENT BASE AL ALUMINUM FUTURE— FUTURE ROUGH IN ONLY RCP REFLECTED CEILING PLAN ALT ALTERNATE RIO RD ROOF DRAIN AP ACCESS PANEL RD/O ROOF DRAIN OVERFLOW APC ACOUSTICAL PANEL CEILING GA GAGE REBAR REINFORCING BAR APPROX APPROXIMATE GALV GALVANIZED REF REFERENCE ARCH ARCHITECTURAL GB GRAB BAR REFR REFRIGERATOR ASPH ASPHALT GC GENERAL CONTRACTOR REINF REINFORCED BD BOARD GL GLASS OR GLAZING REQ'D REQUIRED BETW BETWEEN GLB GLU-LAM BEAM REV REVISION BLK BLOCK GND GROUND RH RIGHT HAND OR ROBE HOOK BLDG BUILDING GR GRADE RESIL RESILIENT BM BEAM GWB GYPSUM WALL BOARD RM ROOM BRG BEARING RO ROUGH OPENING BOT BOTTOM HB HOSE BIB RT RESILIENT TILE BSMT BASEMENT HC HOLLOW CORE OR HANDICAP RUB RUBBER BUR BUILT UP ROOF HDR HEADER RW RAIN WATER HDWD HARDWOOD RWL RAIN WATER LEADER HDWE HARDWARE CAB CABINET HM HOLLOW METAL S SOUTH CB CATCH BASIN HORIZ HORIZONTAL SC SOLID CORE CBU CEMENTITIOUS BACKER UNIT HR HT HOUR HEIGHT SCD SEAT COVER DISPENSER CEM CEMENT HTG HEATING SCHD SD SCHEDULE SOAP DISPENSER CER CFM CERAMIC CUBIC FEET PER MINUTE HVAC HEATING/VENTILATION/ SECT SECTION CFT CONDUCTIVE FLOOR TILE HWH AIR CONDITIONING HOT WATER HEATER SF SHTG SQUARE FEET SHEATHING CG CORNER GUARD CHBD CHALK BOARD IBC INTERNATIONAL BUILDING CODE SIM SNK SIMILAR SINK CI CAST IRON ID INSIDE DIAMETER/ SLR SEALER CJT CLF CONTROL JOINT CHAIN LINK FENCE DIMENSION SND SANITARY NAPKIN IEC INTERNATIONAL ELECTRIC DISPENSER CLG CJ CEILING CONSTRUCTION JOINT IFC CODE COUNCIL INTERNATIONAL FIRE CODE SNR SANITARY NAPKIN CLK CAULKING IG INSULATED GLAZING SPEC RECEPTACLE SPECIFICATION CLO CLOSET IHM INSULATED HOLLOW METAL SQ SQUARE CLR CMU CLEAR CONCRETE MASONRY UNIT IN INCL INCH INCLUDE SST STAINLESS STEEL CNTR COUNTER INSUL INSULATION SSK ST SERVICE SINK STONETILE STONE CO CLEANOUT INT INTERIOR STA STATION COL CONC COLUMN CONCRETE IPC INTERNATIONAL PLUMBING CODE STC SOUND TRANSMISSION CONSTR CONSTRUCTION JAN JANITOR STD CLASS STANDARD CONT CONTINUOUS JT JOINT STL STEEL CORR CPT CORRIDOR CARPET STOR STORAGE CT CERAMIC TILE KIT KO KITCHEN KNOCK OUT STRL STRUCTURAL CTR CENTER KS KNEE SPACE SUSP SV SUSPENDED SHEET VINYL CY CUBIC YARD SYM SYMMETRICAL LAM LAMINATE DBL DOUBLE LAV LAVATORY T TREAD DEPT DEPARTMENT LB, LAG BOLT TB TOWEL BAR DF DRINKING FOUNTAIN(W/O COOLER) LF LINEAL FOOT T&B TOP & BOTTOM DIA DIAMETER LG LENGTH TG TEMPERED GLASS DIAG DIAGONAL LH LEFT HAND THK THICK DIM DIMENSION LINO LINOLEUM TIG TEMPERED INSULATED DISP DISPENSER LKR LOCKER GLAZING DN DOWN LT LIGHT TO TOP OF DR DOOR OR DRAIN TOC TOP OF CONCRETE DTL DETAIL MACH MACHINE TOP TOP OF PAVEMENT DWR DRAWER MATL MATERIAL TOS TOP OF STEEL DS DOWNSPOUT MAX MAXIMUM TOSL TOP OF SLAB DW DISHWASHER MECH MECHANICAL TOW TOP OF WALL DWG DRAWING MEZZ MEZZANINE TPD TOILET PAPER DISPENSER MFR MANUFACTURER TPH TOILET PAPER HOLDER E EAST MH MANHOLE TPTN TOILET PARTITION EA EACH MIN MINIMUM TS TUBULAR STEEL EB EXPANSION BOLT MIR MIRROR TV TELEVISION EJ EXPANSION JOINT MISC MISCELLANEOUS TYP TYPICAL EL ELEVATION MLD MOLDING ELEC ELECTRIC MRGWB MOISTURE RESISTANT GWB UL UNDERWRITERS LABORATORY ELEV ELEVATOR MTD MOUNTED UNF UNFINISHED EM ENTRY MAT MTL METAL UON UNLESS OTHERWISE NOTED EMER EMERGENCY MULL MULLION UR URINAL ENCL ENCLOSURE OR ENCLOSED EP ELECTRICAL PANEL N NORTH VAR VARIES EWC ELECTRIC WATER COOLER NIC NOT IN CONTRACT VCT VINYL COMPOSITION TILE EPX EPDXY NO/# NUMBER VERT VERTICAL EQ EQUAL NOM NOMINAL VEST VESTIBULE EQUIP EQUIPMENT NTS NOT TO SCALE VIN VINYL EST ESTIMATE OA OVERALL VWC VINYL WALL COVERING EX EXPANSION OC ON CENTER EXIST EXT EXISTING EXTERIOR OD OUTSIDE DIAMETER/ W W/ WEST WITH DIMENSION FA FIRE ALARM OFF OH OFFICE OVERHEAD W/O WC WITHOUT WATER CLOSET FBO FURNISHED BY OTHERS OPH OPPOSITE HAND WD WOOD FCIC FURNISHED BY CONTRACTOR OPNG OPENING WF WIDE FLANGE INSTALLED BY CONTRACTOR OPP OPPOSITE WG WIRE GLASS FCTY FACTORY WHSE WAREHOUSE FD FLOOR DRAIN PERP PERPENDICULAR WP WATER PROOF FDN FOUNDATION PFN PREFINISHED WR WATER RESISTANT FE FIRE EXTINGUISHER PL PLATE OR PROPERTY LINE WSCT WAINSCOT FEC FIRE EXTINGUISHER CABINET PLAM PLASTIC LAMINATE INT WEIGHT FF FACTORY FINISH PLYWD PLYWOOD FIN FINISH PNL PANEL XFMR TRANSFORMER FL FLOOR PNT PAINT YD YARD FLG FLASHING PR PAIR m J Q W w W af W 0 U ~I O E ca 1P SYMBOLS COLUMN LINE/GRID LINE DOOR/RELITE NUMBER CORRESPONDS TO ROOM ENTERING 1070 OKEY NOTE PARTITION TYPE X REVISION NUMBER REVISION CLOUD AROUND REVISION MATCH LINE — — SHADED PORTION IS THE SIDE CONSIDERED WORK POINT, CONTROL POINT 4� OR DATUM POINT 1492 EQUIPMENT NUMBER BUILDING SECTION SECTION IDENTIFICATION SHEET WHERE SECTION IS DRAWN DETAIL SECTION SECTION IDENTIFICATION SHEET WHERE SECTION IS DRAWN X DETAIL OR ENLARGED PLAN AU DETAIL IDENTIFICATION so; SHEET WHERE DETAIL IS DRAWN NDo WINDOW SYMBOL PROJECT DIRECTORY ARCHITECT/CONTACT: CRAFT ARCHITECTS, PLLC. CONTACT: GRACE ROBINSON A 2505 THIRD AVE, STE. 324 PHONE: (206) 720-7001 INTtRIOR ELEVATION(S) SEATTLE, WASHINGTON 98121 EMAIL: GRACE®CRAFTARCHITECTS.COM D AXA Br —ELEVATION IDENTIFICATION SHEET WHERE ELEVATION IS DRAWN OWNER: KIDDER MATHEWS CONTACT. ANDREA HACKER 631 STRANDER BLVD. SUITE 6 PHONE: (253) 893-1154 TITLE ROOM IDENTIFICATION TUKWILA, WASHINGTON 98188 EMAIL: AHACKER@KIDDERMATHEWS.COM TITLE TITLE3 ROOM NAME TENANT: HABITAT FOR HUMANITY CONTACT: CYDNIE HORWAT ROOM ROOM NO. PHONE: (425) 466-4499 EMAIL: CYDNIE.HORWAT®HABITATSKC.ORG FINSHED CEILING HEIGHT GENERAL CONTRACTOR: WALSH PACIFIC CONTACT: SCOTT LEE 16400 SOUTHCENTER PARKWAY PHONE: (206) 394-7304 — — PROPERTY LINE SUITE 501 EMAIL: SLEE®WLASHGROUP.COM SEATTLE, WASHINGTON 98188 78 NEW OR FINISHED CONTOURS 71 EXISTING CONTOURS TOP OF WALL 6� �G TOP OF CURB ,,5 TOP OF PAVEMENT �Q. T0065T N PRDJECT NORTH 9'-0" DENOTES CHANGE IN ELEVATION PT FIN13H SYMBOL 2 VICINITY MAP 3523049093 LEGAL DESCRIPTION NUN Ur NW 1/4 OF NE 1/4 OF SEC 35-23-04 TGW POR OF SW 1/4 OF SE 1/4 OF SEC 26-23-04 - BEG NE COR OF NW 1/4 OF NE 1/4 OF SEC 35-23-04 TH N 87-44-08 W ALG N LN OF SD SEC 30 FT TO W MGN OF ANDOVER PARK WEST & TPOB TH S 01-51-39 W ALG SD W MGN 681.34 FT TH N 87-55-02 W 270 FT TH N 01-51-39 E 682.19 FT TH N 01-51-39 E 114.81 FT TH S 87-55-02 E 270 FT TO W MGN OF ANDOVER PARK WEST TH S . 01-47-29 W ALG SD W MGN 115.66 FT TO TPOB LESS POR FOR ACCESS RD CODE/ZONING INFORMATION VUYCRI`IIIVV DUILUINki %AJUC.7: 2012 IBC 2012 UPC 2012 IFC 2009 ICC/ANSI A117.1 (ACCESSIBILITY) 2012 IECC REGULATIONS & ORDINANCES 2012 WASHINGTON STATE AMENDMENTS 2012 WASHINGTON STATE ENERGY CODE VENTILATION PER IMC ZONING DISTRICT: TUC EXISTING/NEW OCCUPANCY CLASSIFICATION: B (OFFICE)/M (MERCANTILE) TYPE OF CONSTRUCTION: III—B SPRINKLER SYSTEM: FULLY SPRINKLERED � OFFICE (EXISTING) (B) 928 SQ FT OFFICE (NEW) (B) 60 SQ FT MERCANTILE (EXISTING) (M) 17,733 SQ FT TOTAL FLOOR AREA: 18,720 SQ FT SITE/BUILDING PLAN NTS 19— •. •.:1. PROJECT DESCRIPTION THIS PERMIT IS FOR THE INSTALLATION OF A RACKING SYSTEM TO STORE BUILDING PRODUCTS. INDEX OF DRAWINGS T1.1 GENERAL INFORMATION & SITE PLAN A2.1 RACKING PLAN FILE CAP Permit No. M .1 - 02-VE Mali review approval is subject to errors and ornissions. Approval of construction documents does not authorize the violation of any adopted cede or ordinance. Recoipt of approvod Hold Copy and conditions is acknowledged: Date: City of Tukwila BUILDING DIVISION REVISIONS No changes &hest ho m 3de to the scr�pP of work t��itho,<� prior appra„;,l of �T'41±tw4a t--Uild!'ng I_�iV F i:r �;. �ti�ill require n P cubmitt.-r 1 �. n a� U rl-aY ►i ".' do additional Plan rev iT ;? 8L'iiicanicat Electrical 9 Piumbino J2'C_'as riping C,' y cf Tukvjila f31J!+.``'! a DIVISION V• K 1 �'. LI i i. A NOV 18 2015 PERMIT CENTER REVtEVVED FOR CODE COMPLIAW APPROVED City of Tukwila ILDING DIVISION www.craftarchitects.com CONSULTANT 705,2 IREGI I>gReIEr v }� YN M CRAFT STATE OF WASSHMIG ON ubmit als/Revisions: 0 11.118115 CITY COMMENTS Sheet Title: GENERAL INFORMATION & SITE PLAN Date: 09/30/15 Design: PE Drawn: TL Project No: 15-096 Approved: KCR Building No: Sheet No: T1.1 COPYRIGHT CRAFT ARCHITECTS 2015 z g Z Y (V E m s n RACKING PLAN SPECIAL INSPECTION FOR STORAGE RACKS (OVER S FEET) (IBC 1707.5.11.7) Periodic special inspection is required during the anchorage of storage racks S feet or greater in height in structures assigned to Seismic Design Category D, E or F. r id TABLE 1705.3 (#4) I1 pection of anchors post. installed in hardened c, _xete members. KEY NOTES O 1. (107) RELOCATED OPEN METAL RACKING T-6' DEEP X 8'-0" HIGH X 8'-0" LONG. SEE STRUCTURAL CALCULATIONS PREPARED BY LUND OPSAHL STRUCTURAL ENGINEERS DATED 9/11/15 FOR BASE ATTACHMENT TO CONCRETE FLOOR SLAB, TYP. 2. (2) CANTILEVER -TYPE RACKING 5'-C" DEEP X 4'-0" LONG. SEE STRUCTURAL CALCULATIONS PREPARED BY LUND OPSAHL STRUCTURAL ENGINEERS DATED 9/11/15 FOR BASE ATTACHMENT TO CONCRETE FLOOR SLAB, TYP. 3. (1) HANGAR -TYPE RACKING T-3" DEEP X 6'-0" LONG. SEE STRUCTURAL CALCULATIONS PREPARED BY LUND OPSAHL STRUCTURAL ENGINEERS DATED 9/11/15 FOR BASE ATTACHMENT TO CONCRETE FLOOR SLAB, TYP. 4. RACKING AREA=12,377 SF 5. TOTAL SHELF HEIGHT = 8. TOTAL STORED HEIGHT = 10' 6. TOTAL SHELF AND STORED HEIGHT = 8'-ld' 7. TOTAL SHELF HEIGHT AND STORED HEIGHT = 11'-6 Habitat for 1® 2505 Third Avenue Suite 324 Seattle, WA 98121 206.720.7001 phone 206.720.2949 fax www.craftarchitects.com CONWILTANT Of N 7052TARCHITEC.TISTERID N M. CRAFT s/ ltvisiorK: 11 /18/15 CITY COMMENTS 8. THE CLASS 4 COMMODITIES ITEMS TO BE STORED INCLUDE TIMBER, TOILETS, SINKS, HARDWARE, DOORS, TILE, FAUCETS AND WINDOWS. THE WINDOWS WILL ONLY BE STORED ON THE LOWEST LEVEL. 9. THE EXISTING SPRINKLER DENSITY IS .39/5600. 10. EXISTING TEMPERATURE RATING FOR FIRE SPRINKLER HEADS IS 160 DEGREES. 11. (2) 32SF SMOKE VENTS IN ROOF ABOVE FOR A TOTAL OF 64SF OF SMOKE VENTS FOR SPACE. • "� " "' °^*+ �� S t itl A ,°`SING PLAN Fj-.�.. ,. ��1' 70t�` Date: 09/30/15 NOV 1 a2015 Design: PE rA PERMIT CENTER Drawn: TL REVIEWED FOR CODE COMPLIANCE APPROVED,* DEC 0 9 2015 City of Tukwila BUILDING DIVISION Project No: Approved: Building No: 0 Sheet No: COPYRIGHT C