Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D15-0268 - DONUT CHAMP - KIOSK
DONUT CHAMP 2800 SOUTHCENTER MALL K-2628 D15-0268 City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 9202470010 Permit Number: D15-0268 Address: 2800 SOUTHCENTER MALL K2628 Issue Date: 11/9/2015 Permit Expires On: 5/7/2016 Project Name: DONUT CHAMP Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940, CARLSBAD, OR, 92013 Contact Person: Name: GUY GIBSON Address: 12369 S NEW ERA RD , OREGON CITY, OR, 97045 Contractor: Name: DIRTY WORK Address: 12369 S NEW ERA RD , OREGON CITY, OR, 97045 License No: DIRTYW*91661 Lender: Name: EMILAGAYEV Address: 9821 NE 122 ST, KIRKLAND, WA, 98034 DESCRIPTION OF WORK: Phone: (503) 720-7558 Phone: (503) 720-7558 Expiration Date: 2/4/2017 UNLOAD KIOSK, ASSEMBLE IN PLACE, EQUIP WITH EQUIPMENT. PLUMBING AND ELECTRICAL UNDER SEPARATE PERMIT Project Valuation: $20,000.00 Fees Collected: $824.42 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: 1116 Occupancy per IBC: M Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No C Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perf mance of work. I am authorized to sign and obtain this development permit a agree to the co i a ched to this permit. Signature- Date:�� J Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All food preparation establishments must have Seattle/King County Department of Public Health sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle/King County Department of Public Health, (206/296-4928), at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 15: Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 13: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 14: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 17: Post address of K-2628 on kiosk per approved Westfield standards. 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING CITY OF TUKh 1LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hitp://www.TukwilaWA.gov SITE LOCATION Building Permit No. Project No. Date Application Accepted: Date Application Expires: or oltice use CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" King Co Assessor's Tax No.: Site Address: IBC y > fs `� Y` C�q J NbFloor: / rte umer:-- Tenant Name: n >^ +ba C. ,/a New Tenant: ....Yes El.. No a PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: C -,-� L Address: f 2. 6 _/ S City: 01 C r ` � State: o j_ Zip: Phone: f63,7t®~ Sf Email: � GENERAL CONTRACTOR INFORMATION Company Name: Address: • a 1 City: State: Zip' . k Phone: v 70 ax: Contr Reg No.: i �/Exp Date: Tukwila Business Lic nse No.: ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: �\ Iv State:1Zip: H:Wpplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page 1 of 4 BUILDING PERMIT INFORMATI( . 206-431-3670 , Valuation of Project (contractor's bid price): $ , Z Q , 00 / Existing Building Valuation: $ Describe the scope of work (please provide detailed information): G1 v� �rr �/ /l' ;, c.�i yj<l'Fy.. w >� Will there be new rack storage? ❑ .... Yes No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 151 Floor %/) . j / A / (/ 2" Floor P Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....... Yes ❑ ....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers .......Automatic Fire Alarm El ....... None El ....... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? � , ....Yes El...... No If "yes, attach list of materials and storage locations on a separate 8-112" x 11 " paper including quanti if es and Material Safety Data Sheets. SEPTIC SYSTEM ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 - Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 4R AU ORI-�' E Signature:Date: �� �`" Print Name: Mailing Address: VhCa Day Telephone: ,SCE 3 0 Pie I,,-(F t? 6 2 City f State H:Wpplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page 4 of 4 � I PUBLIC WORKS PERMIT INFO NATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ... Water District #125 El ... Highline El ... Renton ❑ .. Water Availability Provided Sewer District El.. Tukwila ❑...Valley View ❑... Renton ❑... Seattle ❑ .. Sewer Use Certificate ❑ ...Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which all) ❑ .. Civil Plans (Maximum Paper Size — 22" x 34" ❑ .. Technical Information Report (Storm Drainage) El ... Geotechnical Report ❑ .. Traffic Impact Analysis ❑ .. Bond ❑... Insurance ❑... Easement(s) ❑... Maintenance Agreement(s) ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ ... Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ ... Right-of-way Use — Potential Disturbance ❑ .. Con struction/Excavation/Fi I I - Right-of-way ❑ Non Right-of-way ❑ ❑ .. Total Cut cubic yards ❑ .. Total Fill cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑... Work in Flood Zone El ... Storm Drainage El ... Abandon Septic Tank ❑... Curb Cut El ... Pavement Cut ... Looped Looped Fire Line ❑ .. Permanent Water Meter Size (1) " ❑ .. Temporary Water Meter Size (1) " ❑ .. Water Only Meter Size........... " ❑ .. Sewer Main Extension............ Public ❑ ❑ .. Water Main Extension............ Public ❑ FINANCE INFORMATION Fire Line Size at Property Line ❑ .. Water ❑ .. Sewer Monthly Service Billing to: Mailing Water Meter Refund/Billine: Mailing WO# WO# WO# Private ❑ Private ❑ (2) (2) ❑ ... Grease Interceptor ❑ ... Channelization ❑... Trench Excavation El ... Utility Undergrounding WO # (3) WO # WO # (3) WO # ❑ .. Deduct Water Meter Size " Number of Public Fire Hydrant(s) ❑ .. Sewage Treatment Day Telephone: City Day Telephone: State Zip City State Zip H:\Applications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page 3 of 4 DESCRIPTIONS PermitTRAK PAID $824.42 D15-0268 Address: 2800 SOUITHCENTER MALL Apn: 9202470010 $824.42 DEVELOPMENT $800.30 PERMIT FEE R000.322.100.00.00 0.00 $482.30 PLAN CHECK FEE R000.345.830.00.00 0.00 $313.50 WASHINGTON STATE SURCHARGE 13640.237.114 0.00 $4.50 TECHNOLOGY FEE $24.12 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: ' . . R000.322.900.04.00 0.00 $24.12 $824.42 Date Paid: Thursday, October 08, 2015 Paid By: GUY GIBSON Pay Method: CHECK 1560 Printed: Thursday, October 08, 2015 3:13 PM 1 of 1 -SYSTEMS 1•L INSPECTION RECORD _ Retain a copy with permit IN N N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431--3670 Permit Inspection Request Line (206) 438-9350 P oject: pb�.",f- c Type in�ction: Address: Date Calledj Special Instructions: Date Wan a.m. lRequestet: Phone No: jtnspector: � juatL5 v REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 1 D 2-(g7 INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: j?�� to Type of Inspection: Address: /-, �C ` �- Contact Person: Suite #: Special Instructions: Phone No.: /��) Z Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: -Occupancy Type: Inspector-., { Date: ��3��� Hrs.: /_ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. tsming Aaaress Attn: F Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 We've sold more than 20,000 donut machines since we opened in 1974, and we've never had a single case of accidental fire. Regardless, some local fire codes require the use of automatic fire suppression with our machines. We've got one of the best systems available, already tested to meet current certifications. The automatic Pyro-Chem PCL-300 System is incorporated into our - Odor -Free Down -Draft Filtration System. This system is ANSUUL- 73, CAN/CSA C22.2, N.F.P.A-96, ANSUUL-710B and NSF-59 listed. Shown is our F60-12DDF system for our model SS1200 Donut Machine, mounted in a Formica® clad cabinet with stainless steel counter top. The unit is mounted on 6 casters for easy mobility. Add the custom lighted marquee (as shown) for a real eye catching profit maker. Custom chrome "blow off' caps seal the fire suppression discharge nozzles from contamination. All of our carts are available with custom color or vinyl wrap options. Ask your sales advisor about customizing your cart. 1411141. DONUTS Two chrome discharge nozzles are mounted directly over the cooking area, for fast reliable extinguishing of flames generates in the donut fryer. The Fire Suppressi n 5 1 it (Op the electrical system of the cart and D�+p_�[t�f the unlikely event of a fire, the power to the Pqie an the Down -Draft Filtration Systems ar 'shut down as required b most fire safety codes. mnv 0 5 nj� 5 The built in Fire Suppression System �ous �� al�lUjpv i a container of Potassium Carbonate Solu�\'rait- of-the-art, wet chemical distribution technique is combined with an Automatic Heat Detector as well as a Manual Release Pull Station to provide efficient and reliable protection the moment a fire is detected. This same system is available for either the SS 120 (use F60-12DDF)or the SS2400 (use F60-24DD WeNVEDMachine. Also available in our Vendor Carts, o 200 use FSC-12DDF and for the SS2400 use FSC-24DWT 201,5 t), S " 01 be PERMIT ceraTEr Toy View PCL-300 Control Head Main Power Control Internal View L Plenum Manual Pull Station 0 Discharge Nozzles P Flame Sensor 100 i ) Back View Discharge Nozzles ontrol Head N Discharge Nozzles i 0 PCL-300 Chemical Tank Overall cart dimensions: 24" W x 75" L x 34" H (to countertop -- 72" L without marquee mounting system) �dlitonal Safety Features of the Time Proven SS�I`ZOit Machine UL listed, "Robert Shaw ®" Wain Thermostat adjustable From 200' F to 425° F. UL listed, "Robert Shaw ®" , High Limit Thermostat automatically shuts down the Donut Machine should the shortening temperature reach 425° F. 9 Only 2 quarts of cooking oil are exposed, the balance is under the Automatic Tray assembly 3M '/ Only 7 basic components, allows simple tool free assembly and disassembly 4o! j Heating Control Head includes a safety micro switch which turns off the Donut Machine should the Control Head be lifted out of the shortening while energized. Lill Orbits, Inc. 8900 109`h Ave, Ste 100 • Minneapolis, MN 55316 USA Tel: 763-559-7505 Toll Free: 800-228-8305 Fax: 763-559-7545 www.lilorbits.com . contact@lilorbits.com Lill orbits Model SSw2400 Features: Produces people pleasing profits in no time! • The SS2400 is designed for high traffic locati • Makes all popular size donuts with quick than • Over $800.00 per hour profits possible • 2400 Mini donuts per hour • 360 Large donuts per hour • 480 Medium size donuts per hour • 560 Small donuts per hour • The action, aroma and taste does all the selling • User Friendly... easy to operate i map REVIEWED FOR ?R&COMPLIAW APPROVED NOV 0 5 2015 or yCAty of Tukwila BUILDING DIVISION The SS2400 uses innovations proven in the field by Lil' Orbits over the past 40 years ... a new operator can become skilled in minutes! Variable Speed.. solid state speed control varies output from a Cash Control... tamper -proof digital counter keeps track of every donut made. tantalizing I donut per minute up to full speed. You can pace output to sales demand and always get action attraction. Universal Voltage... Heating Element Easy To Clean .... only 7 basic components. Chain, Sprockets and operates on 208, 220 or 240 volts AC. Motors require conveyors flights have been eliminated. A breeze to clean. 110 volts@ 2.5 amps. Li etame Guarantee... under our extended warranty, all Sets Up In Minutes & Requires components will be repaired or exchanged for a small fee for as long as you Minimum Maintenance ... All components own the machine! FOB Minneapolis, MN. (must purchase mix & shortening can be interchanged at your location without tools. from UP Orbits, Inc.). Additional Safety Features of the SS2400 Machine UL listed, "Robert Shaw C� ' Main Thermostat adjustat from 200' F to 425° F. 0, UL listed, "Robert Shaw C High Limit Thermostat automatically shuts down t Machine should the shorte temperature reach 425° F. G quarts of cooking oil are exposed, lance is under the Automatic Tray bly Only 7 basic components, allows simple tool -free asseml,Zly ( tsa rnbly CITY OF'tUKWII— OCT 0 8 2015 Heating Control Head includes a safety micro switch which turns off the Donut Machine should the Control Head be lifted out of the shortening while energized. Specifications: Dimensions: 42.5" long, 19" wide x 23" high, with all components attached. 4992 watts @ 208 volts, or 5760 watts @ 240 volts AC. Motor controls 110 volts @ 2.5 amps AC. molded plug with ground. All enclosures ETL listed to the following standards: NSF4, UL197, CAN/CSA C22.2 No. 109 Construction: All food grade Aluminum or Stainless Steel. Empty weight approx. 70 lbs. btS*--00Z69 11 1 0 aµ you c@n opente the WNW ff 2224N DORM iNhint• in thO opOn MUM oj t rhmd ti t ntiktion heads' The Downdraft System was designed for use in sites where odor control is required: malls, convention centers, retail stores, etc.. The system includes our built- in Automatic Fire Suppression System. The entire system is self-contained and compactly mounted in a Formica® clad cabinet with stainless steel top. Whether you choose our F60-Series Cabinet (left), or our FSC-Series cabinet (above), you will have a proven profit maker. The system is also available in our popular kiosk package. All of the above includes our patented Downdraft Filtration System and Fire Suppression System. Close-up view shows how the Downdraft housings fit around the Donut Machine. You can hardly tell it's there! And when it's running, it's whisper quiet. All of our Downdraft systems include a comprehensive Fire Suppression System with a total of 4 discharge nozzles, two mounted directly over the Donut Fryer and two more hidden within the sv�stem ; MnQ pull 111 station is also included for added�S'afct t) I !� %___ 0 01 to 6 OCT 0.8 2015 PERMIT CENTER 4 Donut b Machine rl- End Linear Air Plenum �► - - - - Linear Manifold*--PO. II Flexible Conduit Blower 4-Final Filter Pads (6) Activated Carbon Bed Automatic Fire Damper Exhaust Every 8-10 hours, lift out baffled grease filters. Wash, dry and replace. Takes only minutes aVI f l _ r ! ,3 N Every 1000 hours of operation, empty and refill the activated carbon in the final filter bed with our special granulated carbon. Lill Orbits, Inc. 8900 109`h Ave, Ste 100 a Minneapolis, MN 55316 USA Tel: 763-559-7505 Toll Free: 800-228-8305 Fax: 763-559-7545 www.lilorbits.com a contact@filorbits.com Cooking odors are drawn into the Intake Manifold and pass through two Baffle Filter #1 Galvanized Baffled Filters. Any excess oil is collected by the Oil Collector Intake Housing located at the bottom of the Intake Manifold. Next the air passes through Baffle Filter #2 two special Carbonized Filter Pads Filter #3 (filters #3 & #4) which remove any oil vapor and 30 % of cooking odors. The Filter #4 next purification step is the Final Filter Oil Collector Bed, where the air is passed through 4 stages of Activated Carbon Pads. Finally, any trace odors are removed with an Activated Carbon Bed before being exhausted to the floor (see illustration). Every 40 hours of operation, place a new carbonized pad on the bottom, remove and dispose of the top carbonized pad. pr �l f'a 7� ��i�1��L`���i]�vas��c�: �Nc�� �� U�3.11�• ��_ol�+];�'�1 a tia Specifications: Model #F60-12DF, Shipping weight with 6' Formica cabinet (crate included): 435 lbs. (197kg.). Complete unit without crate weighs 320 lbs. (145 kg.) Blower motor is a split -capacitor type, UL recognized #E47479 and #E374403. Rated at 745 CFM. Available in 120V, 60 Hz or 220V-240V, 50 Hz. A�9 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0268 DATE: 10/08/15 PROJECT NAME: DONUT CHAMP SITE ADDRESS: 2800 SOUTHCENTER MALL - K-XX-XX X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 0 k*& IA11 tI MA kW U 11 �? �- P L- N/�% f0-13 lS Building Division Fire Prevention Planning Division Public AV Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 10/13/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: ' DATE: APPROVALS OR CORRECTIONS: Approved n Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DUE DATE: 11/10/15 Approved with Conditions • Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 DIRTY WORK Page I of 2 ]-lone Inido en Espanol Contact Safety (rWashington State Department of ,h Laker & Industries DIRTY WORK Owner or tradesperson GIBSON, GUY DALE Principals GIBSON, GUY DALE, OWNER WA UBI No. 602 374 732 License Search L&I:i=_,;; A-Z Index Help My Secure L".0 Claims & Insurance Workplace Rights Trades & Licensing 12369 S NEW ERA RD OREGON CITY, OR97045 503-720-7558 Business type Individual Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ...._....._._..._..._.............._..._........................ Meets current requirements. License specialties GENERAL License no. DIRTYW*916B1 Effective — expiration 01/21/2009— 02/04/2017 Bond ................. Wesco Insurance Co $12,000.00 Bond account no. 46wb011167 Received by L&I Effective date 12/06/2012 01/21/2013 Expiration date Until Canceled Bond history Insurance Security National Insurance $1,000,000.00 Policy no. NA104222603 Received by L&I Effective date 01/27/2015 01121 /2015 Expiration date 01/21/2016 Insurance history Savings N .......... ... o savings accounts during the previous 6 year period. Lawsuits againstthe bond or savings ws No lauits against the bond or savings accounts during the previous 6 year period. L&I Tax debts, No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ......_............................................... No license violations during the previous 6 year period. https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602374732&LIC=DIRTYW*916B1&SAW= 11/9/2015 C7 : 7 " iT ti3. anicai El r -cal HPIun Bing JO C.:; iping U-' aFn Plan review i� F.ppreval of No chs3 shall b^ —� # of work rrithe) Tlil.... to the smpq f �o��ai of t -- thmittal BT. . Da2z: SCOPE OF WORK: INSTALL A NEW 10' x 1T KIOSK 6s� �.. N EXISTING MALL SPACE. �i�.b TH NEW ELECTRICAL AND P UMBING C NNECTIONS wd is cubject to errors and orn ssivra documents does not authorize V t?eu code or ordinance Czy; c:? d condit 9 Iotyladpr3ti. ��!j ��rCity - � . • ..'a MALL MAP .ice•' IT Working Drawing Review Approved p Approved as Noted p Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is required to be kept on the job site at all times. Signed Date 1 CODE ANALYSIS EXISITING PROPOSED IBC OCCUPANCY CLASSIFICATION B. BUSINESS "B" BUSINESS NFPA OCCUPANCY CLASSIFICATION "B" BUSINESS "B" BUSINESS TYPE OF CONSTRUCTION IIB 116 NO.OF STORIES ABOVE GRADE 2 2 HIGH RISE NO NO COVERED MALL YES YES SPRINKLED YES YES FIRE ALARM YES YES FLOOR AREA OF RENOVATION 170 sq. ft. 170 sq. ft. WALL LEGEND O NEW wALL — — — � C_AC49N wALL ewsnNG wAu ® FIRE PALED wAu STORE LOCATOR o� _ mS $x ��^ o_a +oo r� <� zi3o �`- <r ztoo 2t 25 qT-e ,H•_t• 210 2n0 21, 120 5 zi- iOiALLY CNI ' ��?o' �� � 9 EI 9220 bNf 4 PRE '�13'-10 A G • v't 9 30 w _,• 122 U0,180s1 X CGCA-COLA IDIR . id® kf— - IIp g _1.O. �� T 4R m C:\Users\equintero\Desktop\SCR2-9225-OVERALL-20150616.dwg, 6/16/2015 4:43:29 JOB NUMBER ��_ 1059 t, C_ . SHEET INDEX T-1 COVER SHEET F-1 FINISHES AND MATERIALS A-1 A2 SITE PLAN F-2 FINISHES AND MATERIALS A-2FLOOR PLAN K-1 KITCHEN PLAN A-3 EXT.ELEVATION A S-1 SIGNAGE AND PYLONS A-4EXT.ELEVATION B A-5 EXT.ELEVATION C A-6 EXT.ELEVATION D A-7 INT. ELEVATION A A-8 INT. ELEVATION B A-9 INT. ELEVATION C A-10 INT. ELEVATION D PROJECT DATA MALL: SOUTHCENTER MALL LOCATION: 2800 SOUTHCENTER MAI�j@,F�17'kk%�NaArpi188 n��VVCC�� VV CC11JJ SPACE: 9225 SIZE: 10'X17' CITY OF TUKWILA FLOOR AREA 170 SQ. FT. OCCUPANCY GROUP: BUSINESS BUILDING TYPE: OCT 0.8 2015 SPRINKLED: YES PROJECT DIRECTORY DESIGNER: CONTR6Q1OR_ GRACIE MARASCO REVIEM E04(RORRK WIDE ANGLE MARK 19GODE C 27D OLD COLONY R . Ah E�g-5400 HUBBARDSTON, MAi11452 FAX: (978) 928-5450 TEL: (978) 928-5400 11 FAX: (978) 928-5450 ,i NOV A'O,/ O 2015,'f^L City of Tukwila BUILDING DIVISION 1 �y i IL,W.4 fV LO 0 Ci< 0ZC)o J OOL�n� U D 00 co 0xrna) pO m M rn CV 2: - J J a Q 2 W of LO N Q W � rn a X F- c W W W O E- c Cl) U in O DATE:9.4.2015 SHEET: T-1 JOB NUMBER 1059 x _ Z � Q - - C-o o J w 0 LK-C) N 0 c) T.O _I _ �-m 0C� OZo CD Es 06 C6 U U U� U) 0QO0 pmmo0 (/� `— i W N Q°O �� OO N 1 a _ x _ _W cn _� x �0 '-'',�, �� �O 0� 2150 <� = 2100 Q� �� Qd 2105 � � N 2125 2107 120 21 „ = 2i10 2,15 " 2G -g 2 1 -8 ez F / 37'-5„ 35' 0" 38'-9 / 30 �w � ZE[ 9220 0 9240 FRET ZjfTOTALLY CHI � 180sf y ANGE 110'*-0�' 180sf �a 9 15 WET � � � � © CO 22 E COMPLIANCE:'D FOR 3G°_4„ 3 1 '_ � G„ 18 0 s f 2310 22'-3" of 17os� APPROVED OV 0 5 2015 2305 v, ~ Ln V) `i co �i COCA —COLA DIR �' C-�$ 19 - `C 9227 1* 4 ty of Tukwila ING DIVISION p �, 801 sf�� 20osf ;' _r U, 0 DN TO L1 � 599sf P�NTR _ O " O --- RECEIVED J 4�d bd a N J N N 24' 1" �� SFC11 OF ILIKWILA OCT 0$ 2015 _ = w a �X z W ~ U Z a N 00sf����� PE g�Q - ^ --n �. MIT CENTER o . C:\Users\equintero\Desktop\SCR2-9225-OVERALL-20150616.dwg, 6/16/2015 4:43:29 co DATE:9.4.2015 SHEET: A-1 JOB NUMBER t1 00 LO ti W o o, ao ti FOOD COURT M N CV I== CUT OI TRASH 17'-0" 2'-5" , 3-2" GATE , 5'-6 3/8" 2'-10" , 2'-9 3/4" '+ - I U 110 2'-5" 1 3'-7" 1 1'-11" 1 4' 2 7/8" 1 4'-7 1/8" FLOOR PLAN EQUIPMENT Scale: 3/8" = 1'-0" IiVA on RUSTIC SUNSET SOLID SURFACE ALL COUNTERTOPS AND PYLON N © POS STATION o 0 CAL -MIL PC300-39 THREE TIER PLATINUM PASTRY DISPLAY CASE 16" X 23"X 20" © TRUE TCGD 50 50" BLACK DRY BAKERY CASE ® TOPPINGS PREP. AREA o w m ® SERVER HOT TOPPINGS Zo Q FOOD WARMER ED FOR MPLIANCE 0 SS2400 Donut MachineAPPROVED ®3 BAY COMP. SINK 0 HAND SINK 5 2015 L BUNN 12 CUP AUTOMAT N COFFEE BREWER ANDukwila PREP.AREA DIVISION BEVERAGE AIR BB48G G N — NERATOR RUBBE 57 WASTEBASKET LARGE DEPARTMENT OF PUBLIC HEALTH PERMIT REQUIRED All food preparation establishments must have Seattle/King County Department of Public Health (KCDPH) sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle/King County Department of Public Health, (206/296-4928), at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. Final approval from KCDPH shall be required prior to final approval of building the permit. 1059 a RECEIVED �TY OF TUKWILA ? o z� OCT 0.8 2015 o CENTER N U) po �Q JZOo J OC/)tnln U 0 ao ap Jofrnrn Q0606 C EO N = -LL J J Q U) Z W 0)i J * a W U O _CL 0 N _J 0 0 DATE:9.4.2015 SHEET: A-2 AFFINITY RUSTIC SUNSET SL-143 SOLID SURFACE � CN STAINLESS STEEL -- SPRAYED ON' MDF FINISH TO MATCH TOEKICK MENU TO BE PROVIDED BY CLIENT /3/8" TEMPERED GLASS 4'-10 1/8" V-11 3/4" 1 1'-11 3/4" '1 V-11 3/4" '1 V-11 3/4" 4'-2 7/8." 2'-5 1/8" 2'-5 1/8" 17'-0" n EXT. ELEVATION A Scale: 1/2" = 1'-0" O 04 O 04 if ) l N CV � = RE IEWEP FOR ODE�OM4LIANCE APPROVED NOV 0 5 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF 1'UKWILA OCT 082015 PERMIT CENTER JOB NUMBER 1059 N 0 O Of Q }2 OZ O O J O_cn Ui U? Upcoao �ofrnrn Om0000 pmo:� - N = a 4) �ry H W a a a � J Q Q i- w O H ?� z w w W U Za W 0 X O W DATE:9.4.2015 SHEET: A-3 AFFINITY RUSTIC SUNSET SL-143 SOLID SURFACE 0 N r ' Ri r tf) N CV r � &0 (V STAINLESS STEEL- 3/8" TEMPERED GLASS \WHITE WASH ASH FINISH SPRAYED ON MDF I i I, I, -6" 21-6" 21-611 21-611 11 I, � v I'll 9'-811 2 10'-0" n EXT. ELEVATION B Scale: 1/2" = 1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 5 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 0.8 2015 PERMIT CENTER JOB NUMBER 1059 N LO It ci O Q z O O 000,0 cj O11)� U p oo ao W �rnrn ppmrnrn N 2 I■ J m a a z N a > FU- x z w. Uj W Z� U Q W O ? 0 X O W co DATE:9.4.2015 SHEET: A-4 AFFINITY RUSTIC SUN -SET SL-143 SOLID SURFACE O 3/8" TEMPERED G 3/8" TEMPERED GLASS C) r o iO 1= CN CV 1 coco WHITE WASH ASH FINISH) SPRAYED ON MDF STAINLESS STEEL � 2'-9 3/4" � Z-10" 11 � 2'-9 1 /8" � 2'-9 1 /8" � 3'-2"GATE � 2'-5" i 17'-0" n EXT. ELEVATION C Scale: 1 /2" = 1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 5 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 082015 PERMIT CENTER JOB NUMBER 1059 N d' � Q O Z O O j0Otn OU)InLq C)� 00 00 �C=�rn O m °0 '10 c)maa �� N 2 a J _j U Q ,n O 'ram N x W Z rn Q Zo w Z U Q W O =a co j_: 0O W U) DATE:9.4.2015 SHEET: A-5 JOB NUMBER 0 r- o � CV of N CV M CV 00 STAINLESS STEEL 5 3/8" TEMPERED GLASS WHITE WASH ASH FINISH SPRAYED ON- MDF 9'-8" _2'-3 7/8" 1 2'-3 7/8" 10'-0" n EXT. ELEVATION D Scale: 1 /2" = 1'-0" AFFINITY RUSTIC SUNSET SL-143 SOLID SURFACE l W 2 O W (V Z " D O ~ o N Q 3'-2 7/8" ' 1 2'-1 1 /2" REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 5 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF 1'UKWILA OCT 0.8 2015 PERMIT CENTER 1059 N L0 Q O Q 0 Z O O J 0�LgLq Up00Oo O��rn ppmrnrn N = d m J J 0 Q N O ~ = r LU X Z LLI F.. Z� U W d o O w U) DATE:9.4.2015 SHEET: A-6 0 r � N CN t0 r v- 04 N O7 ce) cy) i N 00 Donut Machine Cart 311 2'-0" DONUT DISPLAY CAS 2'-7 1 /8" INT. ELEVATION A Scale: 1 /2" = 1'-0" 3PEN BACK FOR STO 4'-2 7/8" / 2DOOR UNDERCOUNTER REFRIGERATOR i o N 3E `f>�eli 00 N AL ri N -- 5" 11 " " 1 1 -11 3 -0 '7 ' 1 -11 8/8" ,. -REVIEWED FOR COMPLIANCE PROVED NOV 0 5 2015 v City Of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA, OCT 0.8 2015 PERMIT CENTER JOB NUMBER 1059 (N U) It Q 0 z O O J O�-.Lqa U p 00 00 ��rnrn Omcr)M N 2 J J Q Q a z N 0 _ LJ rn 1- �X Z � > w z� _ 0- W j U) ~ 0 z O DATE:9.4.2015 SHEET: A-7 JOB NUMBER 1059 N O Q O Z O O O LO O O � u Up00OD <rnrn pmrnrn N=a.Lly vz O p N T T QJ W o _ o 10 N CV In T i T CV ' Donut Machine — N N Cart N cM � 71 0O REVIEWED FOR CODE COMPLIANCE APPROVED 61-011 y 101-011 NOV 0 5 2015 n INT. ELEVATION B City of Tukwila a Q m Scale: 1/2" = 1'=0" BUILDING DIVISION Z a- � N LU rn a RECEIVED o W 5 Uj CITY OF TLIKWILA z = a w o z OCT 0.8 2015 ° PERMIT CENTER DATE:9.4.2015 SHEET: A-8 "< �r W g ' _ o _5 A C=— I - - _ o CD N (� I I C.0 i C) N i Donut Machine Cart Ch ;° REVIEWED FOR _jCOC E COMPLIANCE 1 1 /2" '2�' APPROVED f NOV 0 5 2015 2'-3" 3'-211 1'-11 5/8" T-6 3/4" 3'-4 3/4" 2'-01' 3"- 17'-0" City of Tukwila n INT. ELEVATION C BUILDING DIVISION Scale: 1/2" = 1'-0" RECEIVED CITY OP TUKWILA OCT 0 8 2015 PERMIT CENTER JOB NUMBER 1059 N U) � O LZ' Q 0 Z O O JQOLp O~LnLLq Upapo0 0 � 0 m 00 Co r- rn N 2 CC LL Z w x. a I i p d � U a z O Qti ElfN w � .X ZO U T V W ♦J z O U) DATE:9.4.2015 SHEET: A-9 JOB NUMBER 1059 N Ln _NT 0 O } OZ O O J O CD Lq Lq Up0000 j<�rn 0m 000000 p m o- N = aLL 4) o - w i 00 - o o N co co co �o REVIEWED FOR = ODE COMPLIANCE APPROVED 1/2" 3'-2 7/8" 4'-4 5/8" 3" NOV 0 5 2015 10'-0" n INT. ELEVATION D Ci Of Tukwila a < z Scale: 1/2" = 1'-0" E3UiLDING DIVISION _ w N VX Z > W LL; W RECEIVED z = Q W CITY OF TUKWILA o cn z o — OCT 082015 PERMIT CENTER DATE:9.4.2015 SHEET: A-10 I 0 "I S-1WHITE WASH ASH FINISH SPRAYED -ON MDF- FLAME STOP 11 FIRE RETARDANT O SS-1 SOLID SURPACE AFFINITY RUSTIC SUNSET SL-143 COUNTERTOP & PYLONS O L-1 ALLIMASTEEL KICK WILSONART #6277 (419) O G-1 GLASS 3/8"TEMPERED GLASS L-2 WHITE LAMINATE- INTERIOR CABINETS WILSONART DESIGNER WHITE LAMINATE D354-60 G-1 GRAPHIC FOR PYLON O L-3 FRP LINTERIOR WALL PANELS FOOD COURT REVS l',:_AflAlD FOR �7' 0 i3" E C 0 P,,l P-L I A KI C E 11 L 4 .7 Ulf of Tuk-vfila 0UILDIi,,,'G DIVISION RECEIVED CITY OF'rUKWILA OCT 0 18 2015 PERMIT CENTER JOB NUMBER 1059 co _j _j < z jo w LLJ Z (.) L) < Z M < U) 0 a- F- cl) Ill 0 X 0 LL DATE:9.4.2015 SHEET: F-1 JOB NUMBER AALL FIRE RETARDANT TREATED WOOD COMPLIES WITH IBC SECTION 23.03.2 K� \\ _ l" FLAME STOP- II PRODUCT DATA SHEET \ FLAME' STOP INC. 1-877-397-7867 APPLICABLE STANDARDS: A•-•�• a= -� �.aa-P�.a..F�.�.. �w ,�..w,ru. ,. •• ," «... �� nrY�rPP�Pr•�'.w.dr�t�•PI®� APPLLICATIICATIP'^0""rm.sys�a,<"..y APON 'Vehr�•as.a•auaro ur�»P. •x.•v.a DESCRIPTION: _ TECHNICAL SUPPORT _'°•w'�..." wup, avrwawaaa e.�.rw„r'w m•arA.mcw.rwaa.wsa Pwwaa•P Pww• -T,`-1 WI Wr Y.bn: .� n•vr..,Pw �mmx.` am rw...ew.r,••c law. -Mwuamw••.iwu vw.o.q Pwcaa ^•�enob•riM- ro.aa wdumw.nvw ' j -i -7�': M: GNf4aIla MArt taa.YlR'oW PkvAo> r�P�wV from vr�wN'P•..wPwG•W�-a wnmmw•ny� .e �^�•.• TESTING; r. �_.r._.n•r_ ,a wl�uwr c.wm.: __ � a "'" _ _ _ ..._ •» •-. �• •,.ronbaw�.wm, �...• �.m. .� �twPPw.�.�. ma.+.ioawP �"w°' .a.w.xww �>nw..a.....e xa.a.•.. a�•.mw.w .e wrP �.a �.�a... i"wa...�: w�. � o�..�a Kam. was APs><M.acon: ciiw,w�mmr roxiP o? may ue..samm.ammm er � ^w�mww�c..awwa.wx�..w. �w.oa� FIASIC USES. ® rutuwrwo a.nowo�osv.�.eo s.m.s*.u.r n. ww OS P.PP•m. Drli.v. wcprtrax Pwaa,• MY :Jo!Wmrtya.. U'yw Y•xMYw.n'm•Dt kd Ts uo99r8T.tJtT. � e � �- wr awn waoo �`T°PI'ouas enY.mipa P•cm0.aw vluaua UIIM. Nar y�rP1F51M COaMnv OwlP.v 0.6!iW CWKNO4.ISGirnrOn�u�FAC/J �; � .� ADVANTAGES: sm.rba� r O14 .w.Pam wrP. .wR,•apv: wr NOTES: O0•""""°.0i�'•••'-' a• CONTACT US AT: !o�FAX PYRO-GUARD` TREATED PLYWOOD - HOOVER- 17PO R7003 T1L41L-0 WOOD ww� �,,,,a am�cwbwc �• 92481-Mouse Rd. R. WPM, TX 76131 PRODUCTS V., �,,,, Eoarc•:; SPECIES '1O °a'� •-"o -•me"' 0173D6-1222 M 06.1733 6UPiACE rAXSk:G:fURHU17P5K5 ESR.ti6t KU ! RMESPRENf LIMITATIONS: IMo(Memeaapsan 12TklrtOR806YTL1Lv; Su01:i. DE1=:OR?D. .1. rmY61N5PF.CIXX: sln nlnP ARIR)6 J1bRRUTE 1Es; •R•Aa•.'•s-roogw•Fwwv., A-•sc,muw Sw. uv dwya...•Yvwa muP..wip, ��.wau•r.o�..Pn� S.xe.w�aw.e. _ o..iP... """"„ .SIT US AT: wlaun,mo:loP.Pom WARRANTY: ...,n.o..r.mnaa.m ww o.u�aw a,a w•wr>�a wmaw. �ub..m�•n N.�a�.m,o�:.pm. Pw...w.Pw •.�w.P a.. ww _ ..P•.. a a, ww.ria,.�.a.w w mw.oa. Ym�a iww.am«..�.. m.w>xaw�w+r a..cw> w..w,ai.Y.P.=+•r "• Pa..w. ra.....,...�awa. ■SE ON X O'H:R REGuIATOR" x. b S v �'+� s � �+ .s -Ti ,yam ' • .a i'.• 1 ,� = .._�.:eL.�.. i.`„-..�a'�rr,.i....i..i�.'fi..1+.'34L ■SEC ION VI ■ SECT -'AN VPE5ECTION I% PRECAIPIONS FOR CONTROL MEASURES TOXI^,,,)' IOGI-At 'AND.NG 8 USE IN'ORMA':ON a, t � ♦ • P a ■ SE: ON IV ■ SECI'.ON V ■ SECTION vt FIRE AND EXPLOSION REAC'NnY DATA IEAII- +A7ARD:W.A DATA "arvra•rr a- A� ■ SECI:ON ■ SEC'ION I' ■ SEC OK R C,M:CAI PRODLC COMPOST:ON AND P-SICAI AND AND .0 M-- IDENI7Y C•TEM:CAI .FORMATION b wro IWORAW;ON ivay..r Cn ARACIFRST:CS ••wws4»a: ..am ea:i TrPa mot. rrx. oPo1 .wslira,n.mi••a.+r _b.ma.baam.r•. r be.-Lws Mil l,a�n it rma a uv ma. W. •ow• b er . MwvwPaPli,a1•e_•vrwai.aaar� �.a W�'.Nx.r�vr swod•=wOi �w_.bb.r �b mr�a�=m. •aa. w.a..oa ra. rb.bry.`�"-�'°�-a w•N RECEIVED CITY OF TUKWILA OCT 0 8 2015 PERMIT CENTER Ara vw.. •rnav,oavnicauuw. a+Wawa sv w ®®r-��•�a�i.�iw N•re.nnwo•.+m•.�vs. w.. e vv�W lYaa P�.m.P a ea•,a._,.._ a,._b.a..,w.a.�,P...,w.w.wr._ aYae Ya r�orm�br n. x.r. r�r .r�i.w:.�a•s.". �nw.o,. vwnaaw lrt,w.,awwa w-.aeurw,bxvwra.w PaarA'aua •'.:.ww�Pr'P".�'.imr o�m �.a::.,."""a,"'.wx �...� v,Pi.u.w,a0� �-•6ux'Mre.%r..r..••.v.r...'•e�e ve av,er_alw,i„.EIMYarr u..r Pwagrawia.,0l wu. •a.wmrarow.,a,.�aR.�.wa �.';p �.��a�.:ud:o�.,� " ..• -m�a��..�OVKvn •••^•^ww ,maw,.mr• mnr�.wr wry o..•v_v_ .,...,..raa.,.a..eao... ••••aaa•�"•�••e"••�• aYinrww •wu 6s MCl.mso.mr• x LLo �.�n"gym r p'rrwrae. ol�_y�..�i.."�"io�- m.+'m�i Am�nwwr .>ma...am.. • uow�r."v v4AGw 6fOVFmnnila 4y+)n••iea�w wF�naie.m�ia� , �., w.a_aarw,�...�r ... ..yr.a..w....., u�lw.eora, ."o � �wPueAwuw."rin or - RI.nlrlo"ror,Rxe.mo"nex+men wMR11p`'�"uawrrai�emra��1D C i. un uv uwtE io irF �6uYOI- � fMYCfiK ewn.m�rv.c m.r�ro�-". a�rer-�-.n aa,..R. •a..a ,r,a, ww r- ma •ea a.m.w, _ m vn.rww.bm.ar �..wra,.,....m..>ro�,�.�,....w., o�s.uwop.a..�.�...•w�•f.w..iw•sau.vA�P'.++rv�n.m-i1` r,o •'•"aim wnan.r•V v-owrinxs.�r.n.rsw ` ; �.�..�- "- "'° �..a. xf.nmw .n.nwv� r.......ar..w�w.aw.wn.msa.. w«w .z_er��rYmraID¢�e tlP�w��w..�awas .w wm=w,.a..,ww l.aa.aww..w Rv.-nwavracvaaw.�.l.a.l- � ��,P lw_aemra•arw-.mrs-w ba.� °-�-N ,nru.• � wwlxhl.xm,r mv- s..l a....r wa+h .� aulxw�.aar�+wr•iri!P. ia. , b_. :�n�,. e""..::�+ o-'�r.:.`�`.mPa•., ,w.... 1059 N LC) ci O Q Z Z O O J O 0 Ln LLQ U0cocm o<�� Q m � � N = d :ZEVIE F )DE CO 'LI APPROVE- NOV 0 2"15 J J a Q City Of Ill iFA�llacf iL► DiNG 1-'mid N aJ Q w Ca C 0 z Q cn W N z_ LL DATE:9.4.2015 SHEET: F-2 EQUIPMENT SCHEDULE O ITEM MAKER MODEL MEASUREMENTS AMPS VOLTS H2O O POS N/A; N/A N/A N/A N/A 'NiA O PASTRY DISPLAY CASE CAL -MIL PC300-39 THREE TIER W=16"X D=23" H=20" N/A N/A N/A BAKERY CASE TRUE TCGD 5050" W=50 7/8" X D= 35 1/2" X H= 47 7/8" 6 115 N/A 0 TOPPING PANS N/A O SERVER HOT TOPPINGS N/A © FOOD WARMER HATCO GLO-RAY PORTABLEGRFF W=12.4" X D=24" X H= 15.8" 5 N/A 7O DONUT MACHINE LITTLE ORBITS SS2400 W=42 1/2" X D=19" XH= 23„ 2.5 220-240 N/A ® 3 COMP. DROP IN SINK ADVANCE DI-3-10 38 W=" X D=19" X " N/A N/A TABCO H= 10 9O DROP IN HAND SINK ADVANCE DI-1-10SP W=13" X D=19" X N/A. N/A TABCO H= 10" 10 COFFEE BREWER BUNN OW15 -AP' W=9" X D=18.5" X H= 23.6" 11.4 120 N/A JGLASS DOOR KINGS BOTTLE KBU-56-SS W=35.4" X D=21.5" X N/A 115 N/A REFRIGERATOR H= 33.9" WASTE BASKET 2957 W=15.2" X D=11" X 12 RUBBERMAID WAS BASKET H= 19 9„ N/A I N/A N/A TRASH BIN E TOTAL: 4 1. 2'-5" 1[. T-2" GATE 1 L 5'-6 3/8" 1 2'-10" I 2'-9 3/4" 1 v � ' FOOD COURT 00 DONUT °I LI DISPLAY -PASTRY CV Serving Area DISPLAY CUT OUT TRASH 2'-5" 3'-7" "1 1'-111, 4'-2 7/8" 17'-0" KITCHEN PLAN Scale: 1 /4" = 1'-0" 0 0 ❑ ❑ Toppings/Donut N REVIEWED FOR ❑ ❑ Pfep _QDE COMPLIANCE " APPROVED 1 r - 4'-101 " NOV 0 5 2015 4'-7 1 /8' City of Tukwila BUILDING DIVISION RECEIVED CITY OF !'UKWILA OCT 0.8 2015 PERMIT CENTER JOB NUMBER 10591 N It CD �< } Z 0 0 00It� 0-U)LOLo U _LD 06 Dp �Qrnrn 0 co N 2 a J Q W d = ti N _ r x LU W :)c U U = Q o� p U Y 0 co DATE:9.4.2015 SHEET: K-1 ELEVATION B JOB NUMBER CO� ELEVATION A PLAN VIEW Scale: 3/4" = 1'-0" T PYLON - GRAPHIC AND MONITOR o ELEVATION A Scale: 3/4" = V-0" CV CV L 21-4 3/8" 2" 32" MONITOR --MENU BOARD 14 1 6 n SECTION Al-1 Scale: 3/4" = 1 `-011 2'-31' RAPHIO RAP OVER PYLON Co + N 2'-1011 n ELEVATION B Scale: 3/4" = 1'-0" REVIEWED F CODEAPB MPLIANCE ROVED Nov os2015 BUILp /V f Tukwila G DIVISION RECEIVED CITY OF TUKWILA OCT 0 8 2015 PERMIT CENTER 1059 N If) a' Ci O w- Zoo J- 0ut)n U�0000 o<�� oma� N2:— J < U) w a W �X 0 � o w U U Z. Q 0 J C o a O DATE:9.4.2015 SHEET: S-1