Loading...
HomeMy WebLinkAboutPermit D15-0281 - RED ROBIN - FACADERED ROBIN - FACADE 17300 SOUTHCENTER PKWY EXPIRED 07130116 D15-0281 City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 " Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT Parcel No: 2623049110 Permit Number: D15-0281 Address: 17300 SOUTHCENTER PKWY Issue Date: 2/1/2016 Permit Expires On: 7/30/2016 Project Name: RED ROBIN - FACADE Owner: Name: KIR TUKWILA 050 LLC Address: 3333 NEW HYDE PARK RD #100 C/O KIMCO REALTY CORP, PO BOX 5020 NEW HYDE PK, WA, 11042 Contact Person: Name: ROCKWELL WARD Address: 3701 S NORFOLK ST #300 , SEATTLE, WA, 98118 Contractor: Name: ALEGIS CONSTRUCTION INC Address: 6900 SW ATLANTA ST #300, PORTLAND, OR, 97223 License No: ALEGIC1894CN Lender: Name: RED ROBIN INT'L Address: 6312 S FIDDLERS GREEN CIRCLE, GREENWOOD VILLAGE, CO, 80111 Phone: (206) 549-1373 Phone: (503) 970-8312 Expiration Date: 2/19/2017 DESCRIPTION OF WORK: GLAZING SYSTEM Project Valuation: $20,000.00 Fees Collected: $824.42 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Occupancy per IBC: Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: HIGHLINE,TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and gree to the conditions attached to this permit. Signature.1E _ date: Z^ Print This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 0409 FRAMING 0606 GLAZING 4046 SI-EPDXY/EXP CONC -V CITY OF TUK6...,A Community Development Department ,• Building Permit No. I Public Works Department Project No. • Permit Center 6300 Southcenter Blvd., Suite 100 Date Application Accepted: _ Tukwila, WA 98188 Date Application Expires: bttp://www.TukwilaWA.Izov For office 1 CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: Site Address: 1�}3t�v Sov 3�k.�.��t ,ZyyvJL� w , 1;� Suite Number: Floor: Tenant Name: 'LG-k� Vsrbzaa New Tenant: ❑..... Yes El.. No PROPERTY OWNER Name: Address: rr State: Zip: q0i CONTACT PERSON — person receiving all project communication Name: Address. City: State: Zip: b on: : Fax: Email: GENERAL CONTRACTOR INFORMATION Company Name: Address: City: 5613NI State: W� Zip: Phone: �. Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: ARCHITECT OF RECORD Company Name:���� V Architect Name: Address: L �.�� L • �4i0 ciA� S T City: UQ-fCS _ State: Zip:..�bc�4 Phone: 17,L. 1�100 Fax: Email: ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 14 19.27.095) Name: , /1 � l Address: rf !/ G City: Zip:iDO J H:Wpplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page I of 4 BUILDING PERMIT INFORMATI - 206-431-3670 If Valuation of Project (contractor's bid price): $ A [!Q Y-_ 'W r- Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Will there be new rack storage? ❑ .... Yes ❑ ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I` Floor 2 nd Floor 3 rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ ....... Yes ❑ ....... No FIRE PROTECTION/HAZARDOUS MATERIALS: Compact: Handicap: If "yes", explain: ❑ .......Sprinklers ' ❑ .......AvtonlatiE Fire Alai rn El ....... None El ....... Other (specify) • : }. i Will there be storage or use of Mfiitnable corrabusl{{ ible or hazardous materials in the building? ❑ ....... Yes ❑ ...... No If yes', attach list of rnatarials'and storage locations on a separate 8-112" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM '• ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page 2 of 4 PUBLIC WORKS PERMIT INFO__:iATION — 206-433-0179 Scope of Work (please provide detailed information Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ... Water District # 125 El ... Highline ❑. Renton ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑...Valley View ❑... Renton ❑... Seattle ❑ .. Sewer Use Certificate ❑ ...Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which ap ❑ .. Civil Plans (Maximum Paper Size — 22" x 34" ❑ .. Technical Information Report (Storm Drainage) El ... Geotechnical Report El.. Traffic Impact Analysis ❑ .. Bond ❑... Insurance El ... Easement(s) ❑... Maintenance Agreement(s) El.. Hold Harmless — (SAO) El.. Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours El ... Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance El ... Right-of-way Use — Potential Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ .. Total Cut cubic yards ❑ .. Total Fill cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑... Work in Flood Zone El ... Storm Drainage El ... Abandon Septic Tank El ... Curb Cut El ... Pavement Cut ❑... Looped Fire Line ❑ .. Permanent Water Meter Size (1) " ❑ .. Temporary Water Meter Size (1) " ❑ .. Water Only Meter Size ........... " ❑ .. Sewer Main Extension............ Public ❑ ❑ .. Water Main Extension............ Public ❑ FINANCE INFORMATION Fire Line Size at Property Line _ ❑ .. Water ❑ .. Sewer Monthly Service Billing to: Name: Mailing Water Meter Refund/Billine: Name: Mailing Address: 1087:1 WO# WO# Private ❑ Private ❑ (2) (2) ❑... Grease Interceptor ❑ ... Channelization ❑ ... Trench Excavation ❑... Utility Undergrounding WO # (3) WO # WO # (3) WO # El.. Deduct Water Meter Size " Number of Public Fire Hydrant(s) ❑ .. Sewage Treatment Day Telephone: City Day Telephone: State Zip City State Zip H:Wpplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: Febmary 2012 Page 3 of 4 PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. OR AUTHORIZED AGENT: Date: Print Name: -Z�® Day Telephone: 7M0 • \A -1(1-J5 Mailing Address: WIDN 5. )4.zT-®vV-5T. *-SOO W4j �i�11� City State Zip H:4lpplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page 4 of 4 DESCRIPTIONS PermitTRAK QUANTITY PAID $510.92 D15-0281 Address: 17300 SOUTHCENTER PKWY Apn: 2623049110 $510.92 DEVELOPMENT $486.80 PERMIT FEE R000.322.100.00.00 0.00 $482.30 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $24.12 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: .: R000.322.900.04.00 0.00 $24.12 $510.92 Date Paid: Monday, February 01, 2016 Paid By: ROCKWELL WARD Pay Method: CREDIT CARD A57194 Printed: Monday, February 01, 2016 1:53 PM 1 of 1 CI?W SYSTEMS Date Paid: Wednesday, October 28, 2015 Paid By: JON UMBAUGH Pay Method: CREDIT CARD A66774 Printed: Wednesday, October 28, 2015 4:33 PM 1 of 1 (CN? SYSTEMS Structural Analysis January 12, 2016 Red Robin Glazing 17300 Southcenter Parkway Tukwila, Washington 98133 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 8 2016 City of Tukwila BUILDING DIVISION JAN 15 2016 PERMIT CENTER eoRREcTM LTR#- Ie, 019 do oTfpl Ryan Ross, P.E. Andree Yen, E.I.T. Job No. Y-15-071 Table of Contents 1.1 Project Criteria 2.1- 2.5 Wind Analysis 3.1- 3.2 Seismic Analysis 4.1- 4.7 Mullion Design 5.1- 5.2 Section Properties 6.1- 6.7 Connection Design 7.1 Glass Analysis Project: Date: Page: Project Criteria Y-15-071 Red Robin 1/11/2016 1.1 Code References: 2012 Internation Building Code 2012 IBC American Society of Civil Engineers Standards 7-05 ASCE 7-10 2010 Aluminum Design Manual 2010 ADM American Institute of Steel Construction Manual, 13th Edition AISC 13 ACI Building Code Requirements for Structural Concrete 318-08 ACI 318-08 National Design Specification for Wood Construction 2005 NDS USGS 2003 NEHRP Seismic Design Provisions USGS Project Information: Project Name Red Robin Street Address 17300 Southcenter Parkway City Tukwila State Washington Zip Code 98133 Building Criteria: Risk Category = II Type 2012 IBC Table 1604.5 Latitude = 47.448461 Longitude =-122.26182 Project: Date: Page: _ xei:—,J c..,• ^A Annivicic 1:1 CPrnnrl Gusts) Ultimate Design Wind Speed Vult= 110.0 mph Y-15-071 Red Robin 1/11/2016 2.1 2012 Internation Building Code (64) 1(�{SY�) t! O(63) 2012 IBC Figure 1609A %Al: .A Gartnr V V II I%A L., v.......-7 Wind Directionality Factor Structure Type From Table Below Project: Y-15-071 Red Robin Date: Page: 1/11/2016 2.2 ASCE7-10, Table 26.6-1, p250 Kd = 0.85 Factor ASCE 07-05, Table 6-4, p80 Building Components & Cladding Structurte Type Kd Building Main Wind Force Resisting System 0.85 Building Components & Cladding 0.85 Arched Roofs 0.85 Chimneys, Tanks & Similar Structures (Square) 0.9 Chimneys, Tanks & Similar Structures (Hexagonal) 0.95 Chimneys, Tanks & Similar Structures (Round) 0.95 Solid Signs & freestanding Walls 0.85 Open Signs & Lattice Frameworks 0.85 Trussed Towers (Triangle, Square, Rectangle) 0.85 Trussed Towers (All Other Cross Sections) 0.95 *Directionality Factor Kd has been calibrated with combinations of loads specified in Chapter 2. This factor shall only be applied when used in conjunction with load combinations specified in Sections 2.3 and 2.4. vai.,ritii DrocciirP Fxnnsure Coefficient Project: Y-15-071 Red Robin Date: 1/11/2016 Page: 2.3 ASCE7-10, Section 2E ..r....._z . ---- - Velocity Pres. Expos. Coef. Kz = 0.70 Factor Kz = 2.01 (30/1200)A(2/7) Mean Roof Height Z= 14 ft Building Specific Surface Roughness Category = B type Urban and suburban areas, wooded areas, or other terrain with numerous closely spaced B obstructions having the size of single-family dwellings or larger. C Open terrain with scattered obstructions having heights generally less than 30 ft (9.1 m). This category includes fi at open country and grasslands. Flat, unobstructed areas and water surfaces. This category includes smooth mud fl ats, salt fl D ats, and unbroken ice. C t a type -iv, J- N. Exposure a ego.y For buildings with a mean roof height of less than or equal to 30 ft (9.1 m), Exposure B shall apply where the ground surface roughness, as defi ned by Surface Roughness B, prevails in the upwind direction for a Exposure B distance greater than 1,500 ft (457 m). For buildings with a mean roof height greater than 30 ft (9.1 m), Exposure B shall apply where Surface Roughness B prevails in the upwind direction for a distance greater than 2,600 ft (792 m) or 20 times the height of the building, whichever is greater. Exposure C Exposure C shall apply for all cases where Exposures B or D do not apply. Exposure D: Exposure D shall apply where the ground surface roughness, as deft ned by Surface Roughness D, prevails in the upwind direction for a distance greater than 5,000 ft (1,524 m) or 20 times the building height, whichever is greater. Exposure D shall also apply where the ground surface roughness immediately Exposure D upwind of the site is B or C, and the site is within a distance of 600 ft (183 m) or 20 times the building height, whichever is greater, from an Exposure D condition as defi ned in the previous sentence. For a site located in the transition zone between exposure categories, the category resulting in the largest wind forces shall be used. EXCEPTION: An intermediate exposure between the preceding categories is permitted in a transition zone provided that it is determined by a rational analysis method defi ned in the recognized literature. Exposure Case Type Case Table 26.9-1,p256 Terrain Exposure Constants All Componets and Cladding 1 Exposure a zg (ft) Zmin (ft) B 7 1200 30 MWFRS in Low -Rise Buildings 1 MWFRS in All Other Buildings 2 C 9.5 900 15 MWFRS in Other Structures 2 D 11.5 700 7 Exposure Case Type ease = 1 Type ICUM ^uv° REV2 Height AGL Z = 30 ft z 2 30ft for Case 1 in Exposure B Exposure Const. a = 7 Factor Table Above Exposure Const. Zg = 1200 ft Table Above Minimum Height Zmin = 30 ft max of Zmin front TdbleAbove or 0.6 Height REV3 Height AGL Z = 30 ft maximum of Zmin and REV2 Z If: 15ft <_ z <_ zg Then: Kz = 2.01 (Z/Zg)A(2/a) Type 1 Else: z < 15ft Then: Kz = 2.01 (15/zg)A(2/a) Type 2 And: z=30 >_ 15ft So: Kz = 2.01 (30/zg)A(2/a) Type 1 Project: Date: Page: .trn rllltl'� 1-nd-trnr AnnivCIC Y-15-071 Red Robin 1/12/2016 2.4 From Google Earth & ASCE 7-10 Fig. 26.8-1 Topographical Factor Kzt = 1.00 factor Must meet all the following conditions: Meets Conditions 1 THE HIIL, RIDGE OR ESCARPMENT IS ISOLATED AND UNOBSTRUCTED UPWIND BY OTHER SIMILAR NO TOPOGRAPHICAL FEATURES OF COMPERABLE HEIGHT FOR 100 TIMES THE HEIGHT OF THE TOPOGRAPHIC FEATURE (100H) OR 2 MI, WHICHEVER IS LESS. THIS DISTANCE SHALL BE MEASURED HOIZONTALLY FROM THE POINT AT WHICH THE HEIGHT H OF THE HILL, RIDGE, OR ESCARPMENT IS DETERMINED. 2 THE HILL, RIDGE, OR ESCARPMENT PROTRUDES ABOVE THE HEIGHT OF UPWIND TERRAIN NO FEATURES WITHIN A 2 MILE RADIUS IN ANY QUADRANT BY A FACTOR OF TWO OR MORE. 3 THE STRUCTURE IS LOCATED AS SHOWN IN FIG 6-4 IN THE UPPER ONE-HALF OF THE HILL OR NO RIDGE OR NEAR THE CREST OF AN ESCARPMENT 4 H/Lh >=0.2 NO 5 H>15' AT EXPOSURE C&D and H>60' AT EXPOSURE B NO R►!—r I --'J1 f^„rv,r%nnontc and C'liriding Velocity Pressure Project: Y-15-071 Red Robin Date: 1/12/2016 Page: 2.5 ASCE 7-10 Chapter 30 qz = 18.4 psf = 0.00256*(Kz=0.7)*(Kzt=1)*(Kd=0.85)((V=110)^2) V = 110.00 mph From Previous Analysis Basic Wind Speed From Previous Analysis Wind Directionality Factor Kd = 0.85 Factor Velocity Pres. Expos. Coef. Kz = 0.70 Factor From Prevoius Analysis Topographic Factor Kzt = 1.00 Factor From Previous Analysis Wind Analysis C&C Internal Pressure Coef. (+/-) Gcpi = 0.18 factor ASCE 07-10 Table 26.11-1 p257 Enclosure Classification GCpi Open Building +/- 0 Partially Enclosed Building +/- 0.55 Enclosed Building +/- 0.18 Table 26.11-1 Notes: 1. Plus and minus signs signify pressures acting toward and away from the internal surfaces, respectively. 2. Values of (GC ) pi shall be used with qz or qh as specified. 3. Two cases shall be considered to determine the critical load requirements for the appropriate condition: (i) a positive value of (GC ) pi applied to all internal surfaces (ii) a negative value of (GC )pi applied to all internal surfaces Design Pressure Pw = max of qz(+Gcp + Gcpi) & qz(-Gcp + -Gcpi) Min Design Pressure Zone Area (+) Gcp (-) Gcp Ultimate Allowable 10 1 -1.1 23.6 14.2 Field 500 0.7 -0.8 18.1 10.8 10 1 -1.4 29.1 17.5 Corner 500 1 0.7 -0.8 18.1 10.8 ASCE 07-05 - Fig. 6-11 tnru b-i i Pmin = 16 PSf (Ultimate) 9.6 PSf (Allowable) Seismic Analysis (Glass Per SF) Seismic Design Force Seismic Ground Motion: Project: Y-15-071 Red Robin Date: 1/12/2016 Page: Fpa = 4.0 lbs = 0.695 Wp / 1.4 3.1 Maximum Considered Earthquake Ground Motion Specteral Response (5%of Critical Damping), Site Class B 0.2 Second Short Period Ss = 1.448 g USGS 1 Second Period S1= 0.539 g USGS Site Class = D Type ASCE Table 20.3-1 Risk Category = II Type From Project Criteria Calculated Values Site Coefficient per Ss Fa = 1.000 Factor ASCE Table 11.4-1 Site Coefficient per S1 Fv - 1.500 Factor ASCE Table 11.4-2 Maximum Considered Earthquake (MCE) Specteral Response Acceleration Parameters 0.2 Second Short Per Sms = 1.448 g = Fa Ss ASCE Eqn 11.4-1 1 Second Period Sml = 0.809 g = Fv Sl ASCE Eqn 11.4-2 Design Specteral Acceleration Parameters Short Period Sds = 0.965 g = (2/3) Sms ASCE Eqn 11.4-3 1 Second Period Sdi = 0.539 g = (2/3) Sml ASCE Eqn 11.4-3 Seismic Design Category per SDS = D Type ASCE Table 11.6-1 Seismic Design Requirements for Nonstructural Components: Component Attachment Height z = 14.00 Component Operating Weight Wp = 8 Comp. Amplification Factor ap = 1.00 Comp. Response Mod. Factor Rp = 2.50 Component Importance Factor Ip = 1.50 Mean Roof Height h = 14.00 Seismic Design Force Fp = 0.695 Max Seismic Design Force Fpmax = 2.317 Min Seismic Design Force Fpmin = 0.434 Ultimate Seismic Design Force Fpu = 5.56 ft From Project Criteria lb Project Specific Factor ASCE Table 13.5-1 or 13.6-1 Factor ASCE Table 13.5-1 or 13.6-1 Factor ASCE Sec 13.1.3 ft From Project Criteria *Wp = [(0.4 a SDS Wp)/(Rp Ip)][(1 + 2z)/h] Eqn 13.3-1 • Wp = 1.6 SDS Ip Wp ASCE Eqn 13.3-2 * Wp = 0.3 SDS Ip Wp ASCE Eqn 13.3-3 Ibs = 0.695 Wp onni"cic. 1C h4czc PPr SF1 (Continued) Ss = 1.448 g Interpolated Values 0.80 1.00 1.00 1.00 0.90 Project: Date: Page: 14 A cITC rncccll9cNT f n Y-15-071 Red Robin 1/12/2016 3.2 Site Class S, 0.25 0.50 0.75 1.00 1.25 A 0.8 0.8 0.8 0.8 0.8 B 1.0 1.0 1.0 1.0 1.0 C 1.2 1.2 1.1 1.0 1.0 D 1.6 1.4 1.2 1.1 1.0 E 2.5 1.7 1.2 0.9 0.9 F b b I b I b I b NOTE: Use Straight -Line Interpolation for Intermeame values or �s b = site specific values per geotechnicai investigation for T>0.5 sec. (See Section 11.4.7) S1= 0.539 g Interpolated Values 0.80 1.00 1.30 1.50 2.40 . 9 etrc PnrCC1r1c1UT cv Site Class Sl 0.10 0.20 0.30 0.40 0.50 A 0.8 0.8 0.8 0.8 0.8 B 1.0 1.0 1.0 1.0 1.0 C 1.7 1.6 1.5 1.4 1.3 D 2.4 2.0 1.8 1.6 1.5 E 3.5 3.2 2.8 2.4 2.4 F b b I b I b I b NOTE: Use Straight -Line Interpolation for intermemate values ui -N1 b = site specific values per geotechnicai investigation for T>0.5 sec. (See Section 11.4.7) Project: Date: / {� Page: ..........:.....:........................... ... :.....:.....:.......:.......... ' ........:.. ..�... .:.. ... �� .4..... :.. O w A :.. .. ... ................_ ...........,......:............ Sroke FR :. ................ ... ...... _ _.. ..... .. ................... _ ..:....... ..... .. it Via ve, r3i Simole Suaaorted Mullion Design Loading Load Type Zone Type Tributary Width Effective Area Pressure Distributed Load Aluuminum Alloy Mechanical Properties Thickness Range Alloy and Temper Product Types = Wind = Corner = 1.58 feet = 12 sf = 10.9 psf w = 17.22 pif = All = 6063-T6 - C -,-inne A Dinae Project: Date: Page: Y-15-071 Red Robin 1/12/2016 4.2 in Frame Bay Width Bay Width Span Left Right Feet 6.0 0.0 0.0 Inches 0.0 38.0 0.0 Eighths 0.0 0.0 0.0 Total 6.0 3.2 0.0 Selected Eff. Area Field Corner 17.5 10 14.2 17.5 10.8 1 500.00 10.8 10.8 Basic Mechanical Properties Safety Factors Allowable Bending Stress Table 3.3-1 Table 3.4-1 Table 3.4-3 Ftu = 30000 psi nu = 1.95 factor Fty/ny = 15152 psi Fty = 25000 psi na = 1.2 factor Ftu/(Kt nu) 15385 psi Fcy = 25000 psi ny = 1.65 factor Fcy/ny = 15152 psi Fsu = 19000 psi Coefficients Fb = 15152 psi E = 10100000 psi Table 3.4-2 EA = 10000000 psi Kt = 1 Mullion Properties Alum Modulus of Elasticity Yield Strength of Aluminum E = 10000000 PSI C., - )rnnn DU Part No. Part Description Ix Sx Ax 1 OLD CASTLE BE -SERIES CW250 (CW-1) 8.26 2.43 1.75 2 Not Used 0.00 0.00 0.00 3 Not Used 0.00 0.00 0.00 4 Not Used 0.00 0.00 0.00 5 Not Used 1 0.00 0.00 0.00 Design Resi*c 1= S= A= A_ M= V= WProvided From Section Required CapacityY Moment of Inertia 8.26 inA4 Moment of Inertia 0.12 inA4 1.5 Section Modulus 2.43 inA3 Section Modulus 0.10 inA3 4.2 Area 1.75 inA2 Area 0.01 inA2 0.3 Allowable Provided Capacity/o L/175 Deflection 0.41 in Deflection 0.01 in 1.5 Flexure Capacity 1862 Ibs-ft Flexure 77 Ibs-ft 4.2 Shear Capacity 15927 Ibs Shear 52 Ibs 0.3 Upper Jamb Elevation C Satisfactory Additional Moment of Inertia in Aluminum 0.00 Additional Moment of Inertia in Steel 0.00 c,imnlP Sunnorted Mullion Desi.Rn Loading Load Type Zone Type Tributary Width Effective Area Pressure Distributed Load Alluminum Alloy Mechanical Properties Thickness Range Alloy and Temper Product Types = Wind = Corner = 2.50 feet = 15 sf = 10.9 psf w = 27.29 plf = All = 6063-T6 r.,a. t- O. Din Project: Date: Page: Y-15-071 Red Robin 1/12/2016 4.3 In Frame Bay Width Bay Width Span Left Right Feet 6.0 0.0 0.0 Inches 0.0 30.0 30.0 Eighths 0.0 0.0 0.0 Total 6.0 2.5 2.5 Selected Eff. Area Field Corner 17.5 10 14.2 17.5 10.8 1 500.00 10.8 10.8 Basic Mechanical Properties Safety Factors Allowable Bending Stress Table 3.3-1 Table 3.4-1 Table 3.4-3 Ftu = 30000 psi nu = 1.95 factor Fty/ny = 15152 psi Fty = 25000 psi na = 1.2 factor Ftu/(Kt nu) 15385 psi Fcy = 25000 psi ny = 1.65 factor Fcy/ny = 15152 psi Fsu = 19000 psi Coefficients Fb = 15152 psi E = 10100000 psi Table 3.4-2 EA = 10000000 psi Kt = 1 Mullion Properties Alum Modulus of Elasticity Yield Strength of Aluminum E = 10000000 PSI r.. - 'ICnnn DCI Part No. Part Description Ix Sx Ax 1 OLD CASTLE BE -SERIES CW250 (CW-1) 8.26 2.43 1.75 2 Not Used 0.00 0.00 0.00 3 Not Used 0.00 0.00 0.00 4 Not Used 0.00 0.00 0.00 5 Not Used. 0.00 0.00 0.00 Design Rest 1= S= A= A= M= V= �L3 Provided From Section Required Capacity% Moment of Inertia 8.26 in^4 Moment of Inertia 0.19 in^4 2.3 Section Modulus 2.43 in^3 Section Modulus 0.16 in^3 6.6 Area 1.75 in^2 Area 0.01 in^2 0.5 Allowable Provided Capacity% L/175 Deflection 0.41 in Deflection 0.01 in 2.3 Flexure Capacity 1862 Ibs-ft Flexure 123 Ibs-ft 6.6 Shear Capacity 15927 Ibs Shear 82 Ibs 0.5 Upper Jamb Elevation C Satisfactory Additional Moment of Inertia in Aluminum 0.00 Additional Moment of Inertia in Steel 0.00 -I- c... v%,+pfl nniduirin nPCI¢n . IJIJ ✓Jc .J%AVI,.v......... ... ......- Loading Zone Type Tributary Width Effective Area Pressure Distributed Load Alluminum Alloy Mechanical Properties Thickness Range Alloy and Temper Product Types v ■ Corner = 2.50 feet = 18 sf = 33.0 psf w = 82.50 plf = All = 6063-T6 Project: Y-15-071 Red Robin Date: 1/12/2016 Page: 4.5 in Frame Bay Width Bay Width Span Left Right Feet 7.0 0.0 0.0 Inches 0.0 30.0 30.0 Eighths 0.0 0.0 0.0 Total 7.0 2.5 2.5 Selected Eff. Area Field Corner 17.5 10 14.2 17.5 10.8 500.00 10.8 10.8 Basic Mechanical Properties Safety Factors Allowable Bending Stress Table 3.3-1 Table 3.4-1 Table 3.4-3 Ftu = 30000 psi nu = 1.95 factor Fty/ny = 15152 psi Fty - 25000 psi na = 1.2 factor Ftu/(Kt nu) 15385 psi Fcy = 25000 psi ny = 1.65 factor Fcy/ny = 15152 psi Fsu = 19000 psi Coefficients Fb = 15152 psi E = 10100000 psi Table 3.4-2 EA = 10000000 psi I Kt = 1 Mullion Properties Alum Modulus of Elasticity Yield Str th of Aluminun E = 10000000 PSI eng r - Part No. Part Description Ix Sx Ax 1 OLD CASTLE BE -SERIES CW250 (CW-1) 8.26 2.43 1.7S 2 Not Used 0.00 0.00 0.00 3 Not Used 0.00 0.00 0.00 4 Not Used 0.00 0.00 0.00 5 Not Used 0.00 0.00 0.00 Design Res, 1= S= A= A= M= V= Its Provided From Section Required Capacity Moment of Inertia 8.26 in^4 Moment of Inertia 0.93 in^4 11.2 Section Modulus 2.43 in^3 Section Modulus 0.66 in^3 27.1 Area 1.75 in^2 Area 0.03 in^2 1.8 Allowable Provided Capacity90 L/175 Deflection 0.48 in Deflection 0.05 in 11.2 Flexure Capacity 1862 Ibs-ft Flexure 505 Ibs-ft 27.1 Shear Capacity 15927 lbs Shear 289 Ibs 1.8 Upper Jamb Elevation C Satisfactory Additional Moment of Inertia in Aluminum 0.00 Additional Moment of Inertia in Steel 0.00 Design Res, 1= S= A= A= M= V= Its Provided From Section Required Capacity Moment of Inertia 8.26 in^4 Moment of Inertia 0.93 in^4 11.2 Section Modulus 2.43 in^3 Section Modulus 0.66 in^3 27.1 Area 1.75 in^2 Area 0.03 in^2 1.8 Allowable Provided Capacity90 L/175 Deflection 0.48 in Deflection 0.05 in 11.2 Flexure Capacity 1862 Ibs-ft Flexure 505 Ibs-ft 27.1 Shear Capacity 15927 lbs Shear 289 Ibs 1.8 Upper Jamb Elevation C Satisfactory Additional Moment of Inertia in Aluminum 0.00 Additional Moment of Inertia in Steel 0.00 Upper Jamb Elevation C Satisfactory Additional Moment of Inertia in Aluminum 0.00 Additional Moment of Inertia in Steel 0.00 .,.Ir. cs tr%r%^rtarl hAi Blinn npCign Loading Zone Type Tributary Width Effective Area Pressure Distributed Load Alluminum Alloy Mechanical Properties Thickness Range Alloy and Temper Product T Corner = 1.50 feet = 56 sf = 11.5 psf w = 17.21 plf = All = 6063-T6 Project: Y-15-071 Red Robin Date: 1/12/2016 Page: 4.6 "Ell Frame Bay Width Bay Width Span Left Right Feet 13.0 0.0 0.0 inches 0.0 36.0 0.0 Eighths 0.0 0.0 0.0 Total 13.0 3.0 0.0 Selected Eff. Area Field Corner 17.5 10 14.2 17.5 10.8 500.00 10.8 10.8 Types - LAU UJI VI 10 .a, 1+ Basic Mechanical Properties Safety Factors Allowable Bending Stress Table 3.3-1 Table 3.4-1 Table 3.4-3 Ftu = 30000 psi nu = 1.95 factor Fty/ny = 15152 psi Fty = 25000 psi na = 1.2 factor Ftu/(Kt nu) 15385 psi Fcy = 25000 psi ny = 1.65 factor Fcy/ny = 15152 psi Fsu = 19000 psi Coefficients Fb = 15152 psi E = 10100000 psi Table 3.4-2 EA = 10000000 psi I Kt = 1 Mullion Properties Alum Modulus of Elasticity Yield Str th of Aluminun E = 10000000 PSI n- net eng y Part No. Part Description Ix Sx Ax 1 OLD CASTLE BE -SERIES 3000 THERMAL 2.83 1.26 1.07 2 Not Used 0.00 0.00 0.00 3 Not Used 0.00 0.00 0.00 4 Not Used 0.00 0.00 0.00 5 Not Used 0.00 0.00 0.00 Design Resi 1= S= A= J Its Provided From Section Required Capacity% Moment of Inertia 2.83 in^4 Moment of Inertia 1.24 in^4 43.9 Section Modulus 1.26 in^3 Section Modulus 0.48 in^3 37.8 Area 1.07 in^2 Area 0.01 inA2 1.1 Allowable Provided Capacity/ L/175 Deflection 0.89 in Deflection 0.39 in 43.9 Flexure Capacity 962 Ibs-ft Flexure 364 Ibs-ft 37.8 Shear Capacity 9729 Ibs Shear 112 Ibs 1.1 )per Jamb Elevation C Satisfacto Additional Moment of Inertia in Aluminum W Additional Moment of Inertia in Steel 0.1 Mullion Properties Alum Modulus of Elasticity Yield Str th of Aluminun E = 10000000 PSI n- net eng y Part No. Part Description Ix Sx Ax 1 OLD CASTLE BE -SERIES 3000 THERMAL 2.83 1.26 1.07 2 Not Used 0.00 0.00 0.00 3 Not Used 0.00 0.00 0.00 4 Not Used 0.00 0.00 0.00 5 Not Used 0.00 0.00 0.00 Design Resi 1= S= A= J Its Provided From Section Required Capacity% Moment of Inertia 2.83 in^4 Moment of Inertia 1.24 in^4 43.9 Section Modulus 1.26 in^3 Section Modulus 0.48 in^3 37.8 Area 1.07 in^2 Area 0.01 inA2 1.1 Allowable Provided Capacity/ L/175 Deflection 0.89 in Deflection 0.39 in 43.9 Flexure Capacity 962 Ibs-ft Flexure 364 Ibs-ft 37.8 Shear Capacity 9729 Ibs Shear 112 Ibs 1.1 )per Jamb Elevation C Satisfacto Additional Moment of Inertia in Aluminum W Additional Moment of Inertia in Steel 0.1 Design Resi 1= S= A= J Its Provided From Section Required Capacity% Moment of Inertia 2.83 in^4 Moment of Inertia 1.24 in^4 43.9 Section Modulus 1.26 in^3 Section Modulus 0.48 in^3 37.8 Area 1.07 in^2 Area 0.01 inA2 1.1 Allowable Provided Capacity/ L/175 Deflection 0.89 in Deflection 0.39 in 43.9 Flexure Capacity 962 Ibs-ft Flexure 364 Ibs-ft 37.8 Shear Capacity 9729 Ibs Shear 112 Ibs 1.1 )per Jamb Elevation C Satisfacto Additional Moment of Inertia in Aluminum W Additional Moment of Inertia in Steel 0.1 Allowable Provided Capacity/ L/175 Deflection 0.89 in Deflection 0.39 in 43.9 Flexure Capacity 962 Ibs-ft Flexure 364 Ibs-ft 37.8 Shear Capacity 9729 Ibs Shear 112 Ibs 1.1 )per Jamb Elevation C Satisfacto Additional Moment of Inertia in Aluminum W Additional Moment of Inertia in Steel 0.1 )per Jamb Elevation C Satisfacto Additional Moment of Inertia in Aluminum W Additional Moment of Inertia in Steel 0.1 ;rr,r,la CIlnr%nrtPrl Milllinn np_sien .......I -.... --[- I- -- --- Loading Zone Type = Corner Tributary Width = 3.25 feet Effective Area = 48 sf Pressure = 11.4 psf Distributed Load w = 36.92 plf Alluminum Alloy Mechanical Properties Thickness Range = All Alloy and Temper = 6063-T6 Product T es = Extrusions & Pipes Project. Y-15-071 Red Robin Date: 1/12/2016 Page: 4.7 'IF" Frame Bay Width Bay Width Span Left Right Feet 12.0 0.0 0.0 inches 0.0 36.0 42.0 Eighths 0.0 0.0 0.0 Total 12.0 3.0 3.5 Selected Eff. Area Field Corner 17.5 10 14.2 17.5 10.8 500.00 10.8 10.8 Yp Basic Mechanical Properties Safety Factors Allowable Bending Stress Table 3.3-1 Table 3.4-1 Table 3.4-3 Ftu = 30000 psi nu = 1.95 factor Fty/ny = 15152 psi Fty = 25000 psi na = 1.2 factor Ftu/(Kt nu) 15385 psi Fcy = 25000 psi ny = 1.65 factor Fcy/ny = 15152 psi Fsu = 19000 psi Coefficients Fb = 15152 psi E = 10100000 psi Table 3.4-2 EA = 10000000 psi Kt = 1 Mullion Properties Alum Modulus of Elasticity Yield Stren th of Aluminun E = 10000000 PSI .rnnn nci g Part No. r- Part Description Ix Sx Ax 1 OLD CASTLE BE -SERIES 3000 THERMAL 2.83 1.26 1.07 2 Not Used 0.00 0.00 0.00 3 Not Used 0.00 0.00 0.00 4 Not Used 0.00 0.00 0.00 5 Not Used 1 0.00 0.00 0.00 Design Res, 1= S= A= A= M= V= acts Provided From Section Required Capacity/o Moment of Inertia 2.83 inA4 Moment of Inertia 2.09 inA4 74.0 Section Modulus 1.26 inA3 Section Modulus 0.87 inA3 69.1 Area 1.07 inA2 Area 0.02 inA2 2.3 Allowable Provided Capacity/o L/175 Deflection 0.82 in Deflection 0.61 in 74.0 Flexure Capacity 962 Ibs-ft Flexure 665 Ibs-ft 69.1 Shear Capacity 9729 Ibs Shear 222 lbs 2.3 Upper Jamb Elevation C Satisfactory Additional Moment of Inertia in Aluminum 0.00 Additional Moment of Inertia in Steel 0.00 Old Castle BE Project: Date: Page: Y-15-071 Red Robin 1/12/2016 5.1 CW-1 _ nrPa- 1.7520 in^2 I Section Modulus: 2.4332 in^3 I Moment of Inertia: 8.2563 in14 Old Castle BE Project: Date: Y15-071 Red Robin 1/12/2016 Page: 5.2 CW-1 Ara:;- 1 0702 inA2 1 Section Modulus: 1.2572 inA31 Moment of Inertia: 2.8286 inA4 Project: I ��� ��� kO RIB Date: Page: ............. ..... .,...... ..:.....:....:....: ........... ... . :. .... _. _ 4 .. .... . .... ... ..... .......................... . ................ .......... .......... _........ ...:. ; . :. ... ...... ......... .... a..... ... ..... ...... ;...:..............:.. ....... ..... ............ ..... ti ... ...:. :. .:. .....: /—� ... ... .. . .... ,s 1 A...:. Project: Rni T GRnUP ANALYSIS Input Data Number of Bolts #1: #2: #3: #4: Nb 4 Bolt Coordinates Xo (in.) Yo (in.) 1.750 0.000 4.750 . ...:.�.-, ..._,.,,...,_ 0.000 __ . 1,_ ........ 1.750 3.000 4.750 3.000 No. of Load Points N =L-. f J Dn;»t l Load Point Data X-Coordinate (in.) _ Y-Coordinate (in.) _ Z-Coordinate (in.) _ Axial Load Pz (k) = Shear Load Px (k) = Shear Load Py (k) = Moment Mx (in-k) = Moment My (in-k) = Moment Mz (in-k) Project: Y-15-071 Red Robin Date: 1/12/2016 Page: 6.3 Using the Elastic Method for up to 25 Total Bolt: ,esults Bolt Reactions N Axial Rz Shear Rh 0.00 169.51 0.00 78.43 0.00 169.514: 0.00 .......... .. 78.43 . 0.000 0.000 0.000 0.00 0.00 288.75 0.00 0.00 0.00 30 - BOLT GROUP PLOT 2: 2( X - AXIS (in.) Xc = 3.250 in. Yc = 1.500 in. Ix = 9.00 in.A2 ly = 9.00 in.A2 1- 18.00 in.A2 Ixy = 0.00 in.A2 q = 0 .0 00 deg. S Loaos L.G. of tson Grou S Pz = 0.00 kips S Px = 0.00 kips S Py = 288.75 kips S Mx = 0.00 in-k S My = 0.00 in-k S Mz = -938.44 in-k Bolt Reaction Summary: Rz(max) = 0.06 kips Rz(min) = 0.00 kips Rh(max) =1 169.51 Ikips Project: Date: Project: Y-15-071 Red Robin Date: 1/12/2016 Page: Anrhnr flacian 6.5 Design Results Capacity is 1.99 kips Bolt Shear Controls Steel Grade Selection is A36 (M,S,C,MC,L,Plate,Bar) Bolt Shear (�Rn = 1.988 kips = (t n Fn Ab = 0.75*1*24*0.11 Number of Bolts n = 1 Bolts Bolt Yield Strength Fn = 24 ksi Diameter of Bolt Db = 0.375 in Area of Bolt Ab = 0.11 sq in = n(Db^2)/4 = 3.14(0.375^2)/4 Strength Reduction 4) = 0.75 Factor Perpendicular Movement d = 0.5 in Total Allowable Movment = 1 in Bolt Bearing i�Rn = 6.12 kips = (� n 1.0 Fu Lc t = 0.75*1*1.0*58*0.75*0.188 Ultimate Strength Fu = 58 ksi Bearing Type Factor FA1= 0.5 Factor Bearing Type Selection is Bolt to Edge Bolt Hole Clearance Dc = 1/16 in Bolt Hole Diameter Dh = 0.50 in = Db+2*Dc = 0.375 + 2*0.063 Gross Bearing Length S1= 1 in Net Bearing Length Lc = 0.75 in = S1-FA1*Dh = 1-0.5*0.5 Max Bearing Length Lc = 1.00 in = 2*Dh = 2*0.5 Thickness t = 3/16 in Strength Reduction 4) = 0.75 Factor Plate Tension Yielding c�Rn = 18.23 kips = Fy Ag = 0.9*36*0.563 Yield Strength Fy = 36 ksi Plate Perp. Dim. W = 3 in Gross Area Ag= 0.56 sq in = W*t = 3*0.188 Strength Reduction ep = 0.9 Factor Plate Tension Rupture On = 12.23 kips = (P Fu Ae = 0.75*58*0.281 Number of Bolt Holes nbt = 1 qty. Plate Perp. Dim. W = 3 in Net Area Ae = 0.28 sq in = W*t-nbt*(Dh+2A)*t = 3*0.188-1*(0.5+2*0.5)*0.188 Strength Reduction (� = 0.75 Factor Block Shear Strength (�Rn = 15.27 kips = �Rn <_ (�Rn(max) = 0.75*21.206 <_ 0.75*20.363 Block Shear Strength Rn = 21.21 kips = 0.6 Fu Anv + Ubs Fu Ant = 0.6*58*0.141+1*58*0.281 Block Shear Str. Max Rn(max) = 20.36 kips = 0.6 Fy Agv + Ubs Fu Ant = 0.6*36*0.188+1*58*0.281 Gross Length in Tension Ltg = 3 in Bolt(s) Crossing Ltg Bct = 1 qty. Gross Length in Shear Lvg = 1 in Bolt(s) Crossing Lvg Bcv = 0.5 qty. Nominal Area Tension Ant = 0.28 sq in = (Ltg-Bct*(Dh+2A))t = (3-1*(0.5+2*0.5))*0.188 Nominal Area Shear Anv = 0.14 sq in = (Lvg-Bcv*Dh)t = (1-0.5*0.5)*0.188 Gross Area Shear Agv = 0.19 sq in = Lvg*t = 1*0.188 Uniform Stress Coef. Ubs = 1.0 Factor Strength Reduction (� = 0.75 Factor Project: Y-15-071 Red Robin Date: 1/12/16 Page: 6.6 4-.1 re%rhortinn Clip to Steel Structure Shear Connection Capacity AISI E4.3.1 Member 1 Steel Steel Clip Thickness t1= 0.1875 in Ultimate Tensile Strength Ftu1= 45000 psi Member 2 Steel Steel Tube Thickness t2 = 0.25 in Ultimate Tensile Strength Ftu2 = 45000 psi Fastener #10 TEKS Diameter 0.188 in t2/t1 1.33 If t2/t151.0 PnsO 10230 Lbs = 4.2 d(t2A3 d) Ftu2 Pns1 4271 Lbs = 2.7 t1 d Ftul Pns2 5695 Lbs = 2.7 t2 d Ftu2 Pmin1 4271 Lbs Min. Controls If t2/t1 >_ 2.5 Pns1 4271 Lbs = 2.7 t1 d Ftu1 Pns2 5695 Lbs = 2.7 t2 d Ftu2 Pmin2 4271 Lbs Min. Controls If1.0<t2/t1<2.5 Linear Interpolation Pinterp 4271 Lbs = Pmin1+(Pmin2-Pmin1)((t2/t1- 1)/(2.5-1)} Controling Capacity Pns 4271 Lbs Allowable Capacity Pallow = 1424 Lbs = Pns/3 Therfore: Provide (4) #10 TEKS Screws @ EA Clip I;tnrPfrnnt Connection Shear Connection Capacity AISI E4.3.1 Member 1 Aluminum Storefront Mulion Thickness t1= 0.125 in Ultimate Tensile Strength Ftu1= 24000 psi Member 2 Steel Steel Tube Thickness t2 = 0.25 in Ultimate Tensile Strength Ftu2 = 45000 psi Fastener #10 TEKS Diameter 0.188 in t2/t1 2.00 If t2/t1 <_ 1.0 PnsO 10230 Lbs Pns1 1519 Lbs Pns2 5695 Lbs Pmin1 1519 Lbs If t2/t1 z 2.5 Pnsl 1519 Lbs Pns2 5695 Lbs Pm1n2 1519 Lbs if 1.0 < t2/t1 < 2.5 Linear Interpolation Pinterp 1519 Lbs Controling Capacity Pns 1519 Lbs Allowable Capacity Pallow = 506 Lbs Therfore: Provide #10 TEKS Screws @ 18"o/c Project: Y-15-071 Red Robin Date: 1/12/16 Page: 6.7 Storefront to Steel Structure = 4.2 V(t2A3 d) Ftu2 = 2.7 t1 d Ftu1 2.7 t2 d Ftu2 Min. Controls = 2.7 tl d Ftu1 = 2.7 t2 d Ftu2 Min. Controls = Pmin1+(Pmin2-Pmin1)((t2/t1-1)/(2.5-1)) = Pns/3 Project: Y-15-071 Red Robin Date: 1/13/2016 Page: 7.1 Canopy Glass Analysis Fully Tempered 2 Layer Laminated Safety Glass Conforming to the specifications of ANSI Z97.1, ASTM C 3048-97b & CPSC 16 CFR 1201 Glass Properties b Glass Young's Modulus E = 10399000 PSI interlayer Shear Modulus G = 63.8 PSI Long Length b = 94 in a Short Length a = 50.125 in Interlayer Thickness hv= 0.06 in Ply 1 Thickness h1= 0.25 in Ply 2 Thickness h2 = 0.375 in ASTM E1300, X9 - Determining Effective Thickness of Laminated Glass Height Coef. hs = 0.3725 in = 0.5(hi +h2)+hv Ply 1 Height Coef. hs:1= 0.149 in =h5h1/(hl+h2) Ply 2 Height Coef. hs:2 = 0.2235 in =hSh2/(hl+h2) Moment of Inertia Is = 0.0208 inA4 = hl hs:2A2 + h2 hs:1A2 Shear Transfer Coef. R = 0.151 Factor = 1 / (1+9.6 ((E Is hv)/(G hsA2 aA2))) Deflection Laminate Effective Thickness hef:w = 0.47 in = (h1A3 + h2A3+12 R Is)A(1/3) Bending Stress Laminate Effective Thickness hlef = 0.578 in = (hef:wA3/(hl+2 R hs2))A(1/2) Laminate Effective Thickness h2ef = 0.503 in = (hef:wA3/(h2+2 R hs:l))A(1/2) ASTM E3300, Xl.l - Alternate Procedure for Calculating the Approximate Center of Glass Deflection Maximum Glass Deflection as a function of plate geometry and load may be calculated from the following polynomial equations by Dalgliesh. Distributed Load (PSF) q = 31 psf Distributed Load (PSI) q = 0.22 psi = w/144 Polynomial Coef. r0 = -3.36 Factor = 0.553-3.83(b/a) + 1.11(b/a)A2 - 0.0969 (b/a)A3 Polynomial Coef. rl= 2.37 Factor = -2.29 + 5.83(b/a) - 2.17(b/a)A2 + 0.2067(b/a)A3 Polynomial Coef. r2 = 0.23 Factor = 1.485 - 1.908(b/a) + 0.815(b/a)A2 - 0.0822(b/a)A3 Polynomial Coef. x = 0.79 = In(ln(q (ab)A2 / E hef:wA4)) Assumed Deflection S = 0.12 in = hef:w exp(r0+ rl x + r2 xA2) Allowable Deflection Sa = 0.29 in = a/175 0.125 < 0.286 Satisfactory Bending Stress Design Modulas of Rupture Fr = 24000 PSI Safety Factor SF = 2.5 non -guardrail per ASTM E1300 Section Modulas S = 0.011 inA3 = (1/12)(1")hA3 Allowable Bending Moment Mg = 102 Ibs-in =(Fr S)/SF Actual Center of Glass Moment M = 68 Lbs-in = (q aA2)/8 68 < 102 Satisfactory City of Tukwila Allan Ekbere, Mavor Department of Community Development Jack Pace, Director 6/ 1 /2016 ROCKWELL WARD 3701 S NORFOLK ST #300 SEATTLE, WA 98118 RE: Permit No. D15-0281 RED ROBIN - FACADE 17300 SOUTHCENTER PKWY Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/30/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/30/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Riple Permit Technician File No: D15-0281 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development November 16, 2015 ROCKWELL WARD 3701 S NORFOLK ST #300 SEATTLE, WA 968118 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D15-0281 RED ROBIN - FACADE - 17300 SOUTHCENTER PKWY Dear ROCKWELL WARD, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size l 1x17 to maximum size of 2406; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" to be stamped and signed. [Electronic copies shall not be approved.] (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. I could not find any clear details for attaching the solarium at the walls and top of the roof to the existing building. Show positive connections to the existing building to prevent possible seal separation or damage to the building's exterior from pounding affect resulting from a potential seismic event. 2. The plan was not quite clear for the roof. One elevation indicates what appears to be a metal standing/seam roof and the details shows window panels for the roof. Also the bottom edge of the windows (roof glazing) appear to be held by the under seal. Provide clarity for the roof system. Specify supporting members for design snow load of this area, and how the glazed panels shall be attached to resist up lift while allowing rain runoff to prevent puddling at the horizontal seams which could potentially freeze in colder temperatures and cause damage to the roof system. Also show flashing at the top and how it shall be attached and sealed. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)431-3655. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Sincerely, 1r� Bill Rambo Permit Technician File No. D15-0281 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 e Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0281 DATE: 01/20/16 PROJECT NAME: RED ROBIN SITE ADDRESS: 17300 SOUTHCENTER PKWY Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: R3 NN G 1iw Building Division M Fire Prevention Planning Division Public Works Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 01/21/16 Not Applicable Structural Review Required ❑ (no approvallreview required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/18/16 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Plug ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0281 DATE: 11/03/15 PROJECT NAME: RED ROBIN SITE ADDRESS: 17300 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter #, DEPARTMENTS: Revision # before Permit Issued Revision # after Permit Issued At Gp-$- U K M IAA dU Np 11�5 Building Division Fire Prevention No Planning Division �� A'i —0 Ir Public Works ® Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 12/01/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/01/15 Approved ❑ Approved with Conditions ❑ Corrections Required (corrections entered in Reviews) Notation: Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only 1 CORRECTION LETTER MAILED: t'`1"1 Departments issued corrections: Bldg. Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukAilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 01/15/2016 Response to Incomplete Letter # _ Response to Correction Letter # Plan Check/Permit Number: - 01- bN Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Red Robin Project Address: 17300 Southcenter Pkwy Contact Person: Rockwell Ward Summary of Revision: - Stamp and signatures added to noted plan sheets - Details of solarium attachment to roof and building - Clarification of roof system and calculations Phone Number: (206) 549-1373 RECEIVED CITY OF TUKWILA JAN 15 2016 PERMIT CENTER Sheet Number(s): A0.1, 100, 101, 200, 300, 301, 302, 303, 400, 401, Glazing Structural Calm "Cloud" or highlight all areas of revision including date of revision � Received at the City of Tukwila Permit Center by: / 1 I l ❑ Entered in Permits Plus on H:\Applications\Forms-Applications On Line\2010 Applications\7-2010 -Revision SubndttaLdoc Revised: May2011 ALEGIS CONSTRUCTION INC Page 1 of 2 Home FSpaiiol Ccnitact Safety & Health Washington State Department of Labor & Industries ALEGIS CONSTRUCTION INC Owner or tradesperson Principals JONES, BARRIE GLYN, PRESIDENT PRICE, MICHAEL RAY, VICE PRESIDENT PRICE, MARK ALLAN, SECRETARY EVERTON, ROBERT K, TREASURER Doing business as ALEGIS CONSTRUCTION INC Search L&I A-Z Index Help My Secure I: &I Claims & Insurance Workplace Rights Trades & Licensing 6900 SW Atlanta St. Bldg 2, suite 110 PORTLAND, OR97223 503-970-8312 WA UBI No. Business type 603 073 077 Corporation Governing persons BARRIE GLYN JONES DANIEL ANTHONY FINNEGAN; JASON WYNECOOP; MICHAEL RAY PRICE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. ALEGIC1894CN Effective — expiration 02110/2011— 02/19/2017 Bond ................. Travelers Cas and Surety Co of America $12,000.00 Bond account no. 106017187 Received by L&I Effective date 02/1212014 01/12/2014 Expiration date Until Canceled Bond history Insurance Valley Forge Ins Co $1,000,000.00 Policy no. 5086230808 Received by L&I Effective date 06/30/2015 06/28/2015 Expiration date https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603073077&LIC=ALEGICI894CN&SAW= 2/1 /2016 INSTALLATION NOTES: t, THESE DRAWINGS ARE SOLE PROPERTY OF SUPERIOR GLAZING SOLUTION HEREAFTER REFERRED TO INSTALLER. 2. DRAWINGS MAY NOT BE USED OR DUPLICATED WITHOUT WRITTEN CONSENT FROM INSTALLER. 3. APPROVAL BY THE ARCHITECT SHALL CONSTITUTE DESIGN ACCEPTANCE OF THESE DRAWINGS. 4. ALL RECOMMENDED SEALANT TOE BEADS, CAP BEADS AND HEEL BEADS SHOWN ON THESE DRAWINGS SHOULD BE APPLIED AND TOOLED WATER TIGHT ACCORDING TO THE DETAILS AND SEALANT MANUFACTURER'S RECOMMENDATIONS, 5. ALL STEEL ANCHOR CLIPS REINFORCING, ETC. SHALL BE FINISHED WITH RED OXIDE PRIMER. 6, ALL STEEL FASTENERS SHALL BE STAINLESS STEEL U.N.O. 7. INSTALLER IS NOT RESPONSIBLE FOR ALIGNMENT OF VERTICAL & HORIZONTAL FRAMING MEMBERS FROM ONE WINDOW OPENING TO ANOTHER, EXCEPT TWO FRAMES ABUT EACH OTHER. OMIT FROM INSTALLATION FABRICATION NOTES: ROUGH OPENINGS ALL FRAMES & GLASS WILL BE ORDERED BASED ON APPROVED ROUGH OPENINGS (RO). G.C. MUST CONFIRM & APPROVE ALL'RO' DIMENSIONS ON ALL SHOPDRAWINGS, FABRICATION TOLERANCES WINDOW NET FRAME +/- 0.0625 @ 144' CURTAINWALL WALL PLUM +b 0.0625" rQ 144' APPROVALSTAMPS APPROVAL OF SHOPDRAWINGS IS BASED ON PROJECT BEING REVIEWED BY ALL PARTIES AND RELEASED TO FABRICATION AT ONE TIME. ANY CHANGES THEREAFTER MAY REQUIRE A CHANGE ORDER, THESE SHOPDRAWINGS ARE BASED ON OUR GENERAL CONTRACTORS GUARANTEED DIMENSIONS AND ARCHITECTURAL DRAWINGS, DOOR HARDWARE DOOR HARDWARE THAT IS BY OTHERS, WHICH IS TO BE PREPARE FOR BY FABRICATOR, MUST BE RECEIVED AT THE FACTORY BEFORE FABRICATION CAN BEGIN DUE TO VARIATION OF PHYSICAL HARDWARE FROM TEMPLATES. ACCESSORIES GLASS, SETTING BLOCKS, GLAZING, PERIMETER ANCHORS, SHIMS, PERIMETER CAULKING AND INSTALLATION ARE NOT BY FABRICATOR, UNLESS SPECIFICALLY IDENTIFIED ON THESE DRAWINGS. REQUIRED APPROVALS 1, INTERIOR APPLIED CAULKING BY OTHERS. 1. GLAZING SYSTEM SELECTION 2. FINISHES 2. FLASHING BY OTHERS. 3. CAULKING TYPE & COLOR 4. GLASS TYPE 5, FINAL DIMENSIONS CAULKING DOW CORNING 7n BLACK FILE WPY ..j. Nov D )� - Otis 1 r ° I of cogs*(, 3 ­%i-,u t documy.!, t` ^ `:cn of vl y adopted codti ;;e. Receipt cCm�", .,. .: _ �..L,'mowledged: By: Date: City & T BUILDIN' -- . iSION GLAZING SYSTEMS MANUFACTURER ##1 D8 ALUMINUM, LLC LOCATION WOODENVILLE, WASHINGTON WINDOW SERIES NONE CURTAINWALL SERIES NONE DOOR SERIES NONE EXT. STOREFRONT SERIES THERMAL STOREFRONT -SERIES 3000 OLDCASTLE CW 250 INT. STOREFRONT SERIES NONE SHEET LIST o J C COVER SHEET 100 O KEY PLAN 101 N SCHEDULE 200 j SECTION DETAILS 30D= O PLAN DETAILS 400-401 DRAWING VERSION LAST SAVE: 10325015 11'00PM LAST PLOT: 10i1MIS 11.30PM CONTACT INFORMATION 2221 180 PL NE REDMOND, WA 95052 P 425 742 5197 M (425) 830 9912 ALUMINUM FINISH PROJECT RED ROBIN GOURMET BURGERS 17300 SOUTHCENTER PARKWAY ALL EXPOSED ALUMINUM FRAMING AND FORMEDAWMINUM SHAPES FURNISHED BY TUKI ILA WA98188 INSTALLER SHALL BE FINISHED AS NOTED: FRAME FINISH BLACK ANODIZED ARCHITECT BENJAMIN R. URUETA ALL OTHER UNEXPOSED MATERIALS SHALL BE MANUFACTURERS STANDARD SATIN 211 EAST BROAD ST. ALUMINUM COLOR FINISH OR AS NOTED ON DETAILS. GREENVILLE, SC 29MI T. B64232AM F. 864232.7567 GLASS SCHEDULE 1' OVERALL THICKNESS SILICONE SEALED UNITS V LU 1W CLEAR TEMPERED LAMINATED GLASS WITH LOW E ON #2 1CPAIRSPACE WITHBLACKSPACER o_ 11V CLEAR TEMPERED GLASS ZO 1' OVERALL THICKNESS SILICONE SEALED UNITS Q 1/4' CLEAR TEMPERED LAMINATED GLASS WITH LOW E ON #2 Z 1W AIRSPACE WITH BLACK SPACER IN CLEAR TEMPERED GLASS Z DESIGN CRITERIA DESIGNED IN ACCORDANCE WITH 2012INTERNATIONAL BUILDING CODE EXPOSURE NOT USED WINDZONE NOT USED DESIGN WINDLOAD NOT USED CALCULATION NOT USED INCORPORATED NO ENERGY PERFORMANCE RATING NOT USED U-VALUE NOT SPECIFIED SHGC NOT SPECIFIED No changes h-" ; to tho scope of ,York v, t; I' or ;,, co/- I of vviil a r_ .i p:cn submittal %^ may 1'.' L,ud`� acd tionair pan (e`r,e:+1 fees. 'S I,:- PA ril,,71 t PF_:_-i �vl IT M'FIEFOR: Mechanical EI cl ical h Rumbing Gas Piping Clif Cf T,,_Av ;Ia REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 8 2016 City of Tukwila BUILDING DIVISION W L1J U) W LLJ O U DRAWN BY_ JUNED FULL SCALE NTS HALF SCALE NTS JOB NO. SHEET SIZE imir SHEET 1 OF 9 100 08 O J � O U N w a o w 2221 180 PL NE REDMOND, WA 95052 P 425 742 5197 M (425) 830 9912 c o 0 ��Vff 0 0 a a }Q 1 \ 7 W MM � W a O g Q Z z W Av z r i' aQ at 2t '� .�t4 t-4#0 or -lit a REVIEWED FOR � 0 CODE COMPLIANCE F Q APPROVED LAYOUT JAN 2 8 2016 1STOREFRONT/CURTAINWALL Are 1/�2.0 City Of Tukwila DRAWN BY: JUNED FULL SCALE NTS BUILDING DIVISION HALF SCALE NTS JOB NO. SHEET SIZE 111X17" SHEET 2 OF 9 101 0 _j > r 4* 4* Jr 4r r 4r 4* 4* PH I I I I r 'g- REDMOND, WA 95052 P �25 519 425� 742 M 83099172 c 3 300 4\ 4�\ r4 t4 N 2 300 r2 I 300 400 I r— ----------- EVIEWED F6—R CODE COMPLIANCE APPROVED z SOUTH ELEVATION �N NORTH ELEVATION Lij \,IJARCHT-L REF-- I/A3.0 ARCHM W_ 3/A3.0 a JAN 2 8 2016 cr z 0 CitY of Tukwila LBUILDING DIVISION W ---- ---------- ---------- --------------- . . . . . . . . . . .... ........ ........ ........ ....... ........ ... ... ....... ........ ........ - -- --- - - ------- - ------- ...... ...... ..... ....... ....... *.7 . . . . . . . . . . . . ------ ........ .. ....... . ........ . ....... .. ....... 0 ...... ....... ........ I ...... ...... * ...... ....... ....... ........ Lij . ... ....... ........ ......... U) ........ ........ ......... ........ ....... ............. . ...... ...... 06 z 302 _ �31 L�L EL ---------- ------------------ L11 L ------ ------ ----- --- -- ------ - ------ ----- --- - ---- -- ---- ----- ------ ---- ----- - --- DRAWN BY: JUNED 3t at 3t 2t 2t at It FULL SCALE 118*Y-W HALF SCALE 1116'Y-W JOB NO. 01E T E EV S—ECTIaN SHEET SVE 11'X17* S H/MPON (�>Amn L FE _REF SHEET 30F9 200 PRIMARY SEAL & BACKING ROD, MARRY W/ VERRCAL SEAL (BY INSTALLER; D3HEAD DETAIL mcxr, REF.: c c n c C C2TRANSOM DET. W- PRIMARY SEAL BACKING W MARRY W/ VERTIC SEAL (BY INSTALLS SILL DETJ AR ' REF. INTERIOR SEAL do BACKING ROD, BY OTHERS DOUBLE GLAZED ITf GLASS GLAZING GASKET EACH SIDE GLASS SETTING BLOCK DOUBLE GLAZED IIT GLASS SEMBLY SCREWS CH SIDE INTERIOR SEAL do BACKING ROD, BY OTHERS sl DOOR HEAD DETAIL 4 L REF.: GLAZING GASKET EACH SIDE 1" DOUBLE GLAZED UNIT GLASS DOOR SILL DETAIL'' 5 L REF.: i REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 8 2016 City of Tukwila BUILDING DIVISION cm J c 0 .T 2221 180 PL NE REDMOND, WA 95052 P 425 742 5197 M �425 8309912 Q U w O maw a of OO�// W z CD J Q H Lu 0 Z O H U LLI cn DRAWN BY: JUNED FULL SCALE 1= 2 HALF SCALE 1= 4 JOB N0. 11 A11 SHEET SIZE ISHEET 4 OF 9 300 cz 7& 1 •`il Ila I' DOUBLE GLAZED II UNIT GLASS II GLASS SETTING II BLOCK II jPRIMARY SEAL &BACKING ROD I 18RRY W/ VERTICAL SEAL ' v (BY INSTALLER) ° I v - .• Ia .Q • � a 1 I Q - ° A SILL DETAIL . 00 II '-__ II 11181tlAlUllllil - I 1/ <THK PVC SPACER ° I • I • I • v I I . v I �� II II II II II: II 1i. 2' X 4' X 1/8' 7HK II I !I STEEL. HOLLOW SECTION ,I1 i II 9 ! ( 1 1 it 11 ' EXPANSION BOLT, I I I I L=2 II it II ii II Z II. !I ;!g 01 jl II J II _ 18 � II 1L--01 ---- IL SILL ANCHOR � � RW� REVIEWED FOR CODE COMPLIANCE' APPROVED JAN 2 8 2016 City Of Tukwila BUILDING DIVISION_ +m O J C O �ta7 N LL' 2221 180 PL NE REDMOND, WA 95052 P 425) 742 5197 M (425) 830 9912 J H LU 0 z 0 U LU 00 DRAWN BY: JUNED FULL SCALE 1= 2 HALF SCALE 1= 4 JOB NO. 11717' SHEET SIZE SHEET 5 OF 9 301 0.070' THK PAINTED CLADDING EAVES DETAIL 1 ARcH1'l.. R6: 7�� —(4) Or TEKSCREW, L. = 1 1' 3- X 3- X 3/16- THK STEEL ANGLE 0) 0 FLASHING AND o SEALANT BY OTHERS da - Ui y J W t7 W O Q K 2221 180 PL NE REDMOND, WA 95052 P 425) 742 5197 M (425) 830 9912 0 0 ;o FORyE FREVIEWED COMRLIANC APPROVED JAN "2 8 " 2 16 O16 CitY Of Tukwila z� BUILDING DIVISIONmad \ 0 (4) 0&' TEKSCREW, L = 1 J' Z W m W 3- X 3- X 3/16- THK STEEL ANGLE IT THRU BOLT STEEL BEAM SUPPORT BY OTHERS RIDGE DETAIL 2 ARCWI— REF» J_ Q UJ 0 Z O H U LU U) DRAWN BY: JUNED FULL SCALE 1= 2 HALF SCALE 1= 4 JOB NO. 11"X17' SHEET SIZE SHEET 6 OF 9 302 S J C O Z w 2221 180 PL NE REDMOND, WA 95052 ' P (425) 742 5197 M (425) 8309912 N .4 dw�.__ REVIEWED FOR CODE COMPLIANCE 3 X 3" X 3/16- 1HK STEEP. ANGLE APPROVED � z mad a �- - O 01" THRU BOLT JAN 2 8 2016 g City of Tukwila Z �� BUILDING DIVISION (4) 0&" TEKSCREW, L = 1 EOM p4 EOM g0 Z O 0� Ci V LU 07 1 DETAIL @ MIDSPAN SUPPORT ARCM'L REF: DRAWN BY: JUNED FULL SCALE 1= 2 HALF SCALE 1= 4 JOB NO. 11717' SH SHEET 7 OF 9 303 -------------- ------------- --------------- PRIMARY SEAL & BACKING ROD, MARRY W/ HORIZONTAL SEAL—/ (BY INSTALLER) INTERIOR SEAL & ASSEMBLY SCREWS EACH SIDE i JAMB DETAIL `ARCHM REF.: ASSEMBLY SCREWS EACH SIDE GLAZING GASKET EACH SIDE 1" DOUBLE GLAZED UNIT GLASS ASSEMBLY cnnnarc� INTERMEDIATE VERTICAL DETAIL 4 ARCHrL REF.: GLAZING GASKET EACH SIDE 1' DOUBLE GLAZED UNIT' GLASS 7� aaoo INTERIOR SEAL & nanvaan nnn -JAMB DETAIL ASSEMBLY i� `j DLO DLO 41 DLO t4 2 DOOR CLEAR OPENING DOOR CLEAR OPENING 2 DOOR JAMB DETAIL 1 A cmm REF: DOOR JAMB DETAIL 2ARCHM REF: 0) J c 0 .U) ----------- '> — — — — — — — — — — — N� I.L 2221 180 PL NE REDMOND, WA 95052 P 425 742 5197 M (425) 830 9912 c 0 j >0 c IN ----------- ----------- -0 PRIMARY SEAL & BACKING ROD, e MARRY W/ HORIZONTAL SEAL (BY VIEWED FOR CODE COMPLIANCE a APPROVED w z� JAN 2 8 2016 Z 0a o J QV� City of Tukwila ZING DIVISION F WQ� DLO DRAWN BY: JUNED FULL SCALE 1= 2 HALF SCALE 1=4 JOB NO. 11717' SHEET SIZE SHEET 8 OF 9 400 h PAINTED STEEL HOLLOW SECTION, BY OTHERS -\ JAMB DETAIL 1 ARCM*L eff: GLAZING GASKET EACH SIDE 1' DOUBLE GLAZED UNIT GLASS I I I 1 I 1 I I I I 1 I I I I I I I I I I I I II II I cm J C O .N REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 8 2616 2221180 PL NE REDMOND, WA 95052 P 425 742 5197 �425 M 8309912 = o City of Tukwila N(3 DIVISION _r-1 1 I I I I �� � ' � �, o I I a I I I Q I I I I 1 I 11 I F 7 w Z o I I I ma00 CL 0) I I p O rn 5 W c� n/ t7j LL DLO DLO INTERMEDIATE VERTICAL DETAIL 2 Leff: DRAWN BY: JUNED FULL SCALE 1= 2 HALF SCALE 1= 4 JOB NO. 11717' SHEET SRE SHEET 9 OF 9 401 NEW ROOF SYSTEM UNDER SEPARATE PERMIT GLAZING SYSTEM TOP MULLION 2 ^-1 A0.1 1 EXTERIOR ELEVATION - GREENHOUSE SCALE: 1 /8"=1 '-0" G.C. TO PROVIDE CONTI METAL FLASHING TO EC GLAZING SYSTEM TOP tt DRIP EDGE; SLOPE TO HORIZONTAL NOT TO BE THAN 1/8" PER FOOT G.C. TO PROVIDE CONT SEALANT UNDER FLASK VERIFY COMPATIBILTY GLAZING SYSTEM FINIS EXTERIOR GLAZING SY'S COMPONENTS; REFER I GLAZING MANUFACTURI DRAWINGS. 2 WATER PENETRATION DETAIL SCALE: 1 /8"= V-0" REVIEWED FOR )DE COMPLIANCE City of Tukwila ILDING DIVISI NEW STANDING SEA*%E SYSTEM (RIDGE FLASHING PER MANUFACTURER INSTRUCTIONS) UNDER SEPARATE PERMIT LAP CONTINUOUS METAL FLASHING UNDERNEATH NEW ROOF PER ROOF MANUFACTURER INSTRUCTIONS G.C. TO PROVIDE PRESSURE TREATED BLOCKING AS REQUIRED. EXISTING UNDERLYING STRUCTURE; REFER TO STRUCTURAL REtECTWN LTR# I� !7 CI'ry 6F T1 L A JAN 15 2016 PERMIT CENTER �, REGISTERED AARCHITECT BE WASHI DEC 0 O O N 1.. J a) W +- t� 0 L C: a) -c W Qi "~ D 0 V) to m -, Q O N W W W W 0 U W Z m O O , 2 LU Z)0- O C�00W z m p 0 LLJY W 3 �, o O ^ 00 a Q ,? W� Z a W W Q 'S m C� z Q 0 Benjamin R. Urueta Architect 211 East Broad Street Greenville, SC 29601 T.864.232.8200 F.864.232.7587 Draw Checked By DAW BST NTED Date Job No. 14225 Sheet No.