Permit D15-0291 - WASHINGTON PLACE / HOTEL INTERURBAN - MANLIFT
WASHINGTON PLACE MAN YIF D15-0291 City of Tukwila ' Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 0223100090 Permit Number: D15-0291 Address: 223 ANDOVER PARK E Issue Date: 12/4/2015 Permit Expires On: 6/1/2016 Project Name: WASHINGTON PLACE - MANLIFT Owner: Name: WASHINGTON TOWERS LP Address: 18230 E VALLEY HIGHWAY #195 , KENT, WA, 98032 Contact Person: Name: OMAR LEE Address: 18230 E VALLEY HWY, STE 195, KENT, WA, 98032 Contractor: Name: ABSHER CONSTRUCTION CO Address: 1001 SHAW RD , PUYALLUP, WA, 98372 License No: ABSHEC*345PS Lender: Name: WASHINGTON TOWERS LP Address: 18230 E VALLEY HIGHWAY #195 , KENT, WA, 98032 DESCRIPTION OF WORK: Phone: (425) 251-1600 Phone: (253) 845-9544 Expiration Date: 1/8/2017 ERECT & MAINTAIN A MAN & MATERIAL HOIST FOR USE ON THE PROJECT Project Valuation: $15,000.00 Fees Collected: $657.82 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: VB Occupancy per IBC: U Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signatur • Date: Z I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development perryit prrogree to the conditions attached this) permit. Signature:. Da Date:/ Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Applicant shall obtain FAA approval/permit if the subject manlift structure exceeds 200 ft heights above the site ground level. 2: 'BUILDING PERMIT CONDITIONS' 3: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 4: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 5: The special inspections and verifications for concrete construction shall be as required by IBC Chapter 17, Table 1705.3. 6: Installation of high -strength bolts shall be periodically inspected in accordance with AISC specifications. 7: The special inspection of bolts to be installed in concrete prior to and during placement of concrete. 8: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 9: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 10: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 11: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 0201 FOOTING 4000 SI-CONCRETE CONST 4046 SI-EPDXY/EXP CONC 4028 SI-REINF STEEL -WELD CITY OF TUKR A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hLtp://www.TukwilaWA.gov SITE LOCATION Building Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the snail or by fax. "Please Print" Site Address: 223 Andover Park E Tenant Name: PROPERTY OWNER Name: Washington Towers, LP. Address: 1.8230 E Valley HWY #195 City: Kent State: WA Zip: 98032 CONTACT PERSON — person receiving all project communication Narne: Omar Lee Address: 18230 E Valley HWY #195 City: Kent State: WA Zip: 98032 Phone: (425) 251-1600 Fax: (425) 251-1900 Email: omarplee@gmail.com GENERAL CONTRACTOR INFORMATION Company Name: Absher Construction Company, INC. Address: 1001 Shaw Road Croy' Puyallup State: WA Zip: 98371 Phone- (253) 841-9544 Fax: (253) 841-0925 Contr Reg No.: Exp Date: Tukwila Business License No.: King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ .....Yes ❑..No ARCHITECT OF RECORD Company Name: Group West Architects Architect Name: Paul Soldwedel Address: 3601 Fremont Ave N. City: Seattle State: WA Zip: 98103 Phone: (260) 826-4447 Fax: Ernail: psoldwedel@groupwestcompanies.com ENGINEER OF RECORD Company Name: Brienen Structural Engineers, P.S. Engineer Name: Paul J. Brienen , S.E. Address: 596 Industry Drive, Suite 221 City: Tukwila State: WA Zip: 98188 Phone: (206) 397-0000 Fax: Email: pbrienen@bse-ps.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: w�6 I-l) ipl� 1 Address: IV 30 V" M jK;�p� City: W State: W4 Zip: 9SO32 H:\Applications\Forms-Applications On Line\2011 ApplicalionsTermit Application Revised - 8-9-1 I.docx Revised: August2011 Pagel of4 bh BUILDING PERMIT INFORMATIOi 06-431-3670 i Valuation of Project (contractor's bid price): $ 15,000 Describe the scope of work (please provide detailed information): Erect and maintain a man & material hoist for use on the project Existing Building Valuation: L Will there be new rack storage? ❑..... Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per LBC I` Floor 168 3005 2 ad Floor 168 3005 3'd Floor 168 3005 Floors 4 thru 20 2,856 3005 Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑....... Yes 0....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ ....... Sprinklers ❑ ....... Automatic Fire Alarm 0 .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .......Yes © .......No If `yes', attach list of materials and storage locations on a separate 8-112"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 5-9-1 I.docx Revised: August 2011 Page 2 of 4 bh r PUBLIC WORKS PERMIT INFO] ATION — 206-433-0179 4 Scope of Work (please provide detailed infonnation): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ... Water District #125 ❑ .. Highline El.. Renton ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ... Valley View ❑ .. Renton El.. Seattle ❑ ...Sewer Use Certificate ❑... Sewer Availability Provided Septic system: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which aunlv): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Stone Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ .. Right-of-way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ ..Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size.. WO # ❑ ...Water Only Meter Size............ WO # ❑ ...Deduct Water Meter Size " ❑ ...Sewer Main Extension.............Public ❑ Private ❑ ❑ ...Water Main Extension.............Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billine: Name: Day Telephone: Mailing Address: City State Zip H:\Applications\Forms-Applications On Line\201 1 ApplicationsTermit Application Revised - 8-9-1 l.docx Revised: August 2011 Page 3 of 4 bh PERMIT APPLICATION NOTES— i 1, Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Print Namq,�ake Peavler AGENT: Date: 11/18/2015 Day Telephone: (253) 845-9544 Mailing Address: 1001 Shaw Rd. Puyallup WA 98372 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 4 of 4 DESCRIPTIONS• PermitTRAK QUANTITY $408.02 D15-0291 Address: 223 ANDOVER PARK E Apn: 0223100090 $408.02 DEVELOPMENT $388.80 PERMIT FEE R000.322.100.00.00 0.00 $384.30 WASHINGTON STATE SURCHARGE 13640.237.114 0.00 $4.50 TECHNOLOGY FEE $19.22 TECHNOLOGY FEE TOTAL' .$408.02 R000.322.900.04.00 0.00 $19.22 Date Paid: Friday, December 04, 2015 Paid By: OMAR P LEE Pay Method: CREDIT CARD 03843D Printed: Friday, December 04, 2015 10:32 AM 1 of 1 . CRSY57EM5 Date Paid: Wednesday, November 18, 2015 Paid By: JACOB PEAVLER Pay Method: CREDIT CARD 018907 Printed: Wednesday, November 18, 2015 2:14 PM 1 of 1 101 INSPECTION RECORD D�5'0Z L2�,) Retain a copy with permit PECTION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 PA 1ecjS l W Type �I section: Address: GV Date Cafled'. Special Instructions: "t `-t Date Wanted: a.m. _ C p.m. Requester: Phone No: Approved per applicable codes. I—J Corrections required prior to approval. . COMMENTS: Inspector: Date: ! fi REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 73 INSPECTION RECORD Retain a copy with permit 105-nCTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request line (206) 438-9350 Project: i ^ lam'/G�/✓ %)pp Typ of spectior:, Address: e Called: V-4 K, Special Instructions: �Jvt Date Wanted: r �p mj l� p.m. Requester: Phone No: ❑ Approved per applicable codes. El Corrections required prior to approval. Inspector: Date: 12,-7—IS-- F-1 Materials Testing & Consulting, Inc. MTc Geotechnical Engineering & Consulting • Special Inspection • Materials Testing • Environmental Consulting May 17, 2016 Omar Lee Washington Towers LP 18230 East Valley Hwy Suite 195 Kent, WA 98032 Sent via email: omarplee@gmail.com Re: Final Letter RECEIVED Washington Towers LP - Manlift CITY Of TUKWILA 233 Andover Park East Tukwila, WA MTC Project#15BO87 MAY 11 2016 BLDG Permit #D15-0291 PERMIT CENTER Dear Mr. Lee: Materials Testing & Consulting, Inc. (MTC) provided materials testing and special inspection services during construction of the above -referenced project. This letter is a statement declaring the actual work inspected by MTC itemized below was found to be, to the best of the inspector's knowledge, in accordance with project plans, specifications, engineer approved revisions, and the International Building Code. The following is the scope of inspections performed on this project: ♦ Reinforcing Steel ♦ Reinforced Concrete In addition, Moisture -Density Relationship testing and In -Place Densities by Nuclear Method testing were conducted. MTC found the earthwork inspected to be in accordance with project plans, specifications, and engineer revisions or approval. MTC accepts responsibility only for the specific work we inspected, and where an MTC report was generated. The results of our services were provided to the local building department for review. Only WABO Certified special inspectors were utilized to perform those specific inspections as required by the Special Inspection Agreement. Any items that were found to be in noncompliance with the approved construction documents were repaired or replaced, and re -inspected for acceptance. To the best of our knowledge, items that were observed by Materials Testing & Consulting, Inc. during continuous or part time inspections for the noted project are compliant with approved plans and specifications. Page 1 of 2 Corporate • 777 Chrysler Drive • Burlington, WA 98233 • Phone 360.755.1990 • Fax 360.755.1980 SW Region 2118 Black Lake Blvd. S.W.• Olympia, WA 98512 • Phone 360.534.9777 Fax 360.534.9779 NW Region 805 Dupont St, Suite 5 • Bellingham, WA 98226 • Phone 360.647.6061 Fax 360.647.8111 Kitsap Region • 5451 N.W. Newberry Hill Road, Suite 101 • Silverdale, WA 98383 • Phone 360.,698.6787 • Fax 360.692.1919 Visit our website: www.mte-inc.net Materials Testing & Consulting, Inc.AM Geotechnical Engineering & Consulting • Special Inspection • Materials Testing • Environmental Consulting LIMITATIONS The services provided as described in this report include professional opinions and judgment based on the data collected and our field observations. These services have been performed according to the specified codes, industry standards, and generally accepted engineering practices. No warranty, express or implied, is provided. Representatives of Materials Testing & Consulting, Inc. did not supervise, direct, alter, amend or change project specifications or contractor activity. Our statement of conformance pertains to only those items inspected and tested by Materials Testing & Consulting, Inc. for the subject project during the time period when we were on -site. This report may be used only by the client and only for the purposes stated, within a reasonable time from its issuance. Any party other than the client who wishes to use this report shall notify Materials Testing & Consulting, Inc. of such intended use. Based on the intended use of the report, Materials Testing & Consulting, Inc. may require that additional work be performed and that an updated report be issued. Non-compliance with any of these requirements by the client or anyone else will release Materials Testing & Consulting, Inc. from any liability resulting from the use of this report by any unauthorized party. We sincerely appreciate the opportunity to be of service to you on this project and look forward to offering our services again. If you should have any questions concerning this report, please contact the undersigned at your convenience. Respectfully Submitted, MATERIALS TESTING & CONSULTING, INC. Ross Bichel WABO Technical Director Page 2 or 2 RECIr O- ._ CITY OF TU'�%.A MAY 17 zu b PERMIT CEN`l EP Corporate • 777 Chrysler Drive • Burlington, WA 98233 • Phone 360.755.1990 • Fax 360.755.1980 SW Region 2118 Black Lake Blvd. S.W.• Olympia, WA 98512 • Phone 360.534.9777 • Fax 360.534.9779 NW Region 805 Dupont St, Suite 5 • Bellingham, WA 99226 Phone 360.647.6061 Fax 360.647.8111 Kitsap Region • 5451 N.W. Newberry Hill Road, Suite 101 • Silverdale, WA 98383 • Phone 360,698.6787 • Fax 360.692.1919 Visit our website: www.mte-inc.net Materials, Testing & Cons l in Inc.l � �r+�I[ 6nIsa11 E lnsuiitin �psgtEl l� ps itm 141itl�i 17ft*R * En+ runm 10 Qa>1 111be� Washington Towers LP - 15BO87 - Compression Test: Concrete: Report #C42234 CLIENT AM Wealth .DATE 12/02/2015 PROJECT :LOCATION 233 Andover Park East PERMIT # D15-44-tfi Tukwila WA 98188 ° z1 Cl Inspection Information: ��s' _ ov--? I Inspection Date: 12/02/2015 Time Onsite: 08:00 a1n Weather Conditions: Overcast. 40's F Inspection Performed: Compression Test: Concrete Field Data (ASTM C-31): Location of Placement: Man and materialJillfoundation grade beams Sample Location: Man and material lift llxmdation north grade beam Contractor Absher Construction Subcontractor: Conco Cement Comp Supplier/Plant: Mites - 203 Qty Placed, Cu. Yd.: 9 of 15 Slump, Inches (ASTM C-143) or W/C Ratio: 0.42 Concrete Temp, OF(ASTM C-]064): 61 Delivery Ticket #: 155498 Job Spec. Slump: 0.44 Ambient Temp, °F: 45 Truck #: M074 Air Content, 0/6 (ATSM C-231): NA Min Temp, IF: Batch Time: 0,916 Job Spec. Air: NA Max Temp, IF: Sample Time: 0920 Mix # and Proportions: 124001= Cement, lbs.: 4055 Coarse Agg, lbs.: 13960 (#57) Admixture, oz./cwt: Flyash, lbs.: 1010 Coarse Agg, lbs.: 3240 08) Admixture, oz./cwt: Water, gals.: 251.5 Coarse Agg, lbs.: Admixture, oz./cwt: Fine Agg, lbs.: 13220 Coarse Agg, lbs.: Admixture, oz./cwt: Sample Type & Compression Test Results: Received 12/03/2015 Sample Set 1 of] Type of Compression Test: Concrete (ASTM C-39) Lab Tests: Test Total Sample. Comp. Sample Dim. Break ASTM ASTM New Log # Age Date of Test Load Area (Sq. Strength Tested By Days (Days) Lbs. (In') 1n ( ) ) (PSI) Type C-617 C-123I 8126 7 12/09/2015 40.470 4.00 12.57 1220 .Jordan Ulrich 5 0 8127 28 12/30/2015 55.385 4.00 12.57 4.410 .Jordan Ulrich 5 0 8128 56 01/27/2016 68.020 4.00 12.57 5A10 Jordan Ulrich 5 0 8129 56 01/27/2016 67.490 4.00 12.57 5.370 Jordan Ulrich 5 0 8130 56 01/27/2016 68.090 4.00 12.57 5A20 .Jordan Ulrich 5 ❑ REQ'D 28 5000 Remarks: RECEIVED Please reference field report. CITY OF TUKWILA Sample Ps 8128. 8129. 8130 have been moved to 56 day test due to low 28 day result. FEB 0 2 2016 PERMIT CENTER �l �cnrrt!a�@1rR!+.�h+l llr�'�hR�ll�l.:��44�AM1.,:. �6� R4fI1R�1��l4h+r�+i+��F.1r4'(4Mk191i!RRh'�+.111A.45�F R'I�Mr44'9L.Lkt.:,���dp�'Ott'i#'�7!'±°k��R1r+Rhr4t'L+...r<.1�f'4t?�:1�� oa rrrr :rs; aa�.anabecEmad .pa e4raatRq�mri'.:n 3401 - 3;113 mawla.f■ rearing i. C visulpinl. 1r4 A11 r11.1cr reasrrrl. Carparate * 777 Cbryxler Drive * &li¢rlingtan, WA 982,11.1 f Firode 360.73S.1090 1?rs 364:73S.:1480 4b K, Materials Testing m Consulting, Inc. Gfoleft1twi FAVM*nft & 00fluiffing I driz 0 ED nm - RI rin ,F4wkwrrJAovn-umg R.J."PORTED BY: Jordan Ulrich REVIEWED BY: Cheryl Meredith, Lab Manager RECEIVED CITY OF TUKWILO FEB 0 2 20"I'S PERMIT CENTER *'map PW,4"*'q "f1%rvt*-tk rwk AH -m"wr PPOO-" m I Pool at **w"*. -N~" w 4mwwwmw:wm m ty4w""n:bua sirraMcl wins wrwnf,,0 3401 - 3,113 H star Isis ra at in I is co-* a uma, I. Nro, A 11 r I It at mcrrv,4 . Carpairmit * 777 Chrysler nFrIVe Burfingtom, WA -99233 * ltharj2e JOH) -733-,1990,* Fox 360.7,95,,1980 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 5/3/2016 OMAR LEE 18230 E VALLEY HWY, STE 195 KENT, WA 98032 RE: Permit No. D15-0291 WASHINGTON PLACE - MANLIFT Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/4/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/4/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely,-11' W- "-Inn __ 44 Bill Rambo Permit Technician File No: D15-0291 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0291 DATE: 11/18/15 PROJECT NAME: WASHINGTON PLACE - MANLIFT SITE ADDRESS: 223 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter #, DEPARTMENTS: �& PD 110) Building Division Public Works Non -Structural ❑ APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections BBenttered in QReevviews) j, n Notation:NUI_ "/ REVIEWER'S INITIALS: Revision # before Permit Issued Revision # after Permit Issued �Ftnevention Planning Division Structural ❑ Permit Coordinator a Energy Code ❑ DUE DATE: 12/17/15 Approved with Conditions Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 ABSHER CONSTRUCTION CO Home tnicio en l;spanol Contact. Page I of 4 Search L&1 ' a* Safety Washington State Department of Labor & Industries ABSHER CONSTRUCTION CO A-Z.Index Help My Secure IkU Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson PO BOX 280 PUYALLUP, WA98371 Principals 253-845-9544 ABSHER, DANIEL RHEA, PRESIDENT PIERCE County ABSHER, THOMAS LOWELL, VICE PRESIDENT TANSBE, LANE STUART, TREASURER WEHRY, JOSEPH R, AGENT SAYRE, BRADLEY C, SECRETARY (End:01/18/2006) HELLE, GREGORY A, VICE PRESIDENT (End: 12/26/2014) SAYRE, BRADLEY C, VICE PRESIDENT (End: 12/26/2014) HELLE, CLARK E, VICE PRESIDENT (End: 12/26/2014) Doing business as ABSHER CONSTRUCTION CO WA UBI No. Business type 275 003 716 Corporation Governing persons BRADLEY C SAYRE DANIEL R ABSHER; GREG A HELLE; THOMAS L ABSHER; THOMAS R ABSHER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .........._.............................................................. Meets current requirements. License specialties GENERAL License no. ABSHEC"345PS Effective — expiration 10/10/1966— 01/08/2017 Bond ................. Safeco Ins Cc of America $12,000.00 Bond account no. 69s009838 Received by L&I Effective date 05/11/2012 04/20/2012 Expiration date https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=275003716&LIC=ABSHEC*345PS&SAW= 12/4/2015 GENERAL REQUIREMENTS SUMMARY OF WORK Project consists of new construction as shown on these Contract Documents used in coordination with the building structural drawings and other discipline's documents. DEFINITIONS The following definitions are used throughout these structural notes: IBC - Governing code, including local amendments SER -Structural Engineer of Record per these Contract Documents LINO - unless noted otherwise GOVERNING CODE All design and construction shall conform to the 2012 International Building Code and local jurisdiction amendments. Reference to ASTM and other standards shall refer to the latest edition designated by IBC Chapter 35. Refer to the specifications for Information in addition to that covered by these structural notes and drawings. DOCUMENTS Structural Documents shall be used in conjunction with building structural drawings and Architectural Documents for all bidding and construction. Drawings indicate general and typical details of construction. Typical details and general notes shall apply even if not specifically denoted on plans, LINO. Where conditions are not specifically indicated similar details of construction shall be used, subject to review and approval by the Architect and the SER. These Contract Documents and any materials used in preparation of them, including calculations, are the exclusive property of the SER and can be reproduced only with the permission of the SER, WARRANTY The SER has used that degree of care and skill ordinarily exercised under similar circumstances by members of the profession in this locale and no other warranty, either expressed or implied, is made in connection with rendering professional services. OWNER RESPONSIBILITY The owner shall retain a Special Inspector to perform the special inspection requirements required by the building official and as outlined in the Special Inspection section below. DESIGN CRITERIA The foundation has been designed to support the following manlift reactions provided by Morrow: STATIC LOADS BASE ENCLOSURE: 4.7 KIP HOIST CAR: 11.1 KIP PAYLOAD: 14.1 KIP MAST SECTIONS: 11.3 KP SUB TOTAL OF STATIC LOADS: 41.2 KIP MAST TIES & CABLE GUIDES: 4.1 KIP TOTAL STATIC LOADS: 45.3 KIP DYNAMIC LOADS IMPACT ON MOVING PARTS: HOIST CAR: 11.1 KIP PAYLOAD: 14.1 KIP TOTAL DYNAMIC LOAD: 25.2 KIP FOOTING LOADS TOTAL LOAD ON FOOTING (STATIC + DYNAMIC): 70.5 KIP LOAD PER MAST LEG (CASE 1) - EMERGENCY STOP ON MAST: 16.5 KIP LOAD PER MAST LEG (CASE 11) - EMERGENCY STOP ON BUFFER: 3.9 KIP LOAD PER BUFFER (MAX.): 8.4 KIP The Manlift Tie -In anchorage has been designed for the following reactions provided by Morrow: MAXIMUM REACTION FORCES SHOWN No io r Chan 9es shall to th be made e Of wort( t�ythcLrt prr a scope Ttat<t��ila But PPProval of i fC�' : ;�li�;- R • �► Division. ''� e✓Itt require a new plan submittal and mayb"c,'uda addi#ional Plan review fees PLANNING APPROVED No Chan es 'can be � made. to ti7eBe plans without approval from the Planning Division of DCD i Approved I3r vlmaen REINFORCING BAR LAP SPLICE & DEVELOPMENT LENGTH DIAGRAMS The following conditions must be met In order to use the Reinforcing Bar Lap Splice & Development Length Tables CONTRACTOR PERFORMANCE REQUIREMENTS DESIGN DOCUMENTS Contractor shall verify all dimensions and all conditions at the job site, including building and site conditions before commencing work, and be responsible for same. All discrepancies shall be reported to the Engineer before proceeding with work. Any errors, ambiguities and/or omissions in the contract documents shall be reported Immediately, in writing. No work is to be started before correction is made. Contractor shall verify and/or coordinate all dimensioned openings and slab edges shown on the contract documents. Some dimensions, openings and embedded items are shown on the structural drawings. Others may be required. Refer to architectural drawings for size and location of curbs, equipment pads, wall and floor openings, architectural treatment, embeds required for architectural items and dimensions. Refer to mechanical, plumbing, electrical and fire protection drawings for size and location of all openings for ducts, piping, conduits, etc. Submit openings to architect for review. Do not scale drawings. Use only field verified dimensions. When electronic plan files are provided for the contractor's detailing convenience, it shall be noted that the electronic files are not guaranteed to be dimensionally accurate. The contractor uses them at his own risk. The published paper documents are the controlling Contract Documents. Electronic files of detail sheets and notes will not be provided. CONTRACTOR -INITIATED CHANGES Contractor -initiated changes shall be submitted in writing to the Engineer for review and acceptance prior to fabrication or construction. Changes shown on shop drawings only will not satisfy this requirement. INSPECTIONS The contractor shall coordinate with the building department for all building department required permits and inspections. SAFETY PROCEDURES Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the contractor's work. The Structural Engineer has no overall supervisory authority or actual and/or direct responsibility for the specificworking conditions at the site and/or for any hazards resulting from the actions of any trade contractor. The Structural Engineer has no duty to inspect, supervise, note, correct, or report any health or safety deficiencies to the owner, contractors, or other entities or persons at the project Uo vi'�Q� L �-t Pe-v*_4 r• � Q 111Kr eX,1�, o rA Vq ( j� /A 1io �- �v sN(Se�v SHOP DRAWINGS AND SUBMITTALS See building structural drawings for all shop drawings and submittal requirements. INSPECTIONS See building structural drawings for all inspection requirements, i Pro v; cue 5�-«e i (far e t ok a rv" F roc! comic -e� aK d Co KCr� e.X �cx S r a �cG�o rr o ct . GEOTECHNICAL Manlift foundation is supported by building foundation. See building structural drawings for all geotechnical information. CONCRETE STRENGTH REQUIREMENTS Concrete shall be mixed, proportioned, conveyed and placed In accordance with IBC Section 1904, 1905, 1906 and ACI 301, including testing procedures. Concrete shall attain a 28-day strength of f c = 5,000 psi, see building structural drawings for all addition concrete mix requirements and information. REINFORCEMENT IN CONCRETE REINFORCING STEEL Reinforcing steel shall conform to ASTM A615 (including supplement Si), Grade 60, Fy = 60,000 psi, except any bars specifically so noted on the drawings shall be Grade 40, Fy=40,000 psi. See building structural drawings for additional information. CONCRETE COVER FOR REINFORCING STEEL Reinforcing Bar Location Min Concrete Cover UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#6 BARS AND LARGER) 2" FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#5 BARS AND SMALLER) 1 1/2" COLUMNS AND BEAMS w/ BARS ENCLOSED IN STIRRUPS, TIES OR SPIRAL REINF 1 1/2" (TO PRIMARY REINF) SLABS, JOISTS AND INTERIOR FACES OF WALLS (#6 BARS AND LARGER) db+ 5/8" SLABS, JOISTS AND INTERIOR FACES OF WALLS (#5 BARS AND SMALLER) 3/4" 2-HOUR AND 3-HOUR SLABS (REFER TO PLAN NOTES) CLEAR SPACING BETWEEN PARALLEL BARS IN A LAYER (BARS ENCLOSED IN STIRRUPS/TIES) 1" CLEAR SPACING BETWEEN PARALLEL BARS IN A LAYER (NO STIRRUPS/TIES) 2db CLEAR SPACING BETWEEN (2) OR MORE PARALLEL LAYERS 1" NOTES: 1. WHERE ATHICKNESS OF COVER REQUIRED FOR FIRE PROTECTION IS GREATER THAN THAT SPECIFIED IN THIS TABLE, THE GREATER THICKNESS SHALL BE USED. Concrete Cover Scale: 3/4" = V-0" Lap Splices Straight Bar Development Hooked Bar Development CLASS 1: Bars enclosed by db CLR. (MIN) db CL column ties or � �I beam stirrups o• • EDGE OF CONC. REINF. BAR EDGE OF CONC, REINF. BAR COL. TIES OR SPLICED BAR COL. TIES OR 2 1/2" BM STIRRUPS BM STIRRUPS CLR (MIN.) c z iv CLASS 2: No enclosure 2db CLR. (MIN) 2db CLR. (MIN) v Q• • S D. HOOK EDGE OF CONC. REINF. BAR EDGE OF CONC. REINF. BAR ry u SPLICED BAR Where conditions for Classes 1 & 2 MULTIPLY LENGTHS SHOWN IN SCHEDULE BY 1.5 MULTIPLY LENGTHS SHOWN IN SCHEDULE BY 1.5 are not met Reinforcing Bar Lap Splice & Development Le Scale: NTS Tables NOTES: 1. ALL BARS SHALL BE DEVELOPED & ALL SPLICES LAPPED PER ACE 318 FOR TENSION, LINO. TABLE MAY BE USED WHERE CONDITIONS MEET CRITERIA NOTED IN DIAGRAMS. 2. TABLES ARE APPLICABLE FOR NORMAL WEIGHT CONCRETE, ONLY. 3. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12" DEPTH OF CONRETE CAST BELOW THEM. (WALL HORIZONTAL REINFORCEMENT IS EXEMPT) 4. WHERE BARS OF DIFFERENT SIZE ARE LAP SPLICED, SPLICE LENGTH SHALL BE THE LARGER OF: -DEVELOPED LENGTH OF LARGER BAR -SPLICE LENGTH OF SMALLER BAR 5. WHERE MINIMUM STRAIGHT BAR DEVELOPMENT LENGTH CONNOT BE ACHIEVED, USE Ldh WITH STANDARD HOOK. 6. REFER TO CONCRETE COVER TABLE FOR MINIMUM CONCRETE COVER REQUIREMENTS. GRADE BEAM REINF PER ELEVA" DOWELS TO M/ GRADE BEAM V GRADE BEAM HORIZON' PER ELEVA' DOWELS TO M/ GRADE BEAM V' Detail Scale: 1" = V-0" REINFORCING BAR LAP SPLICE & DEVELOPMENT LENGTH TABLE f'c = 5,000 psi Grade 60 Reinforcing SLAB PER BUILDING DRAWINGS 1ST FLOOR 0'-0" )E BEAM PER PLAN )E BEAM VERTS ELEVATION l�l�lu�»lll�_V. CAP PER DING DRAWINGS BO Elevator Pit -5' - 6" Bar Size Min Lap Splice Lengths (�) Min Straight Bar Development Lengths (Ld) Min Hooked Bar Embedment Lengths (Ldh) Top Bars Other Bars Top Bars Other Bars #3 22" 17" 17" 13" 7" #4 29" 22" 22" 17" 9" #5 36" 28" 28" 22" 11.1 #6 44" 34" 34" 26" 13" #7 63" 49" 49" 38" 15" #8 72" 56" 56" 43" 17" #9 81" 63" 63" 48" 20" #10 91" 70" 70" 54" 22" #11 102" 78" 78" 60" 24" P�t ►i SIT f'6Z0UIP,} l=%Xft: P001cbsnical ectrical �fiJmbing Gas Piping U; Y of Tukwila ?I�� DIVISION I QnMUC DIVI I I I I I 18" MANLIFT SLAB, PLACE I I I INTEGRAL W/ BUILDING SLAB I I I I I I I I I SAWCUT LOCATION AFTER MANLIFT REMOVAL I I I I l i I I I I I i I I I I -------1-- 1 ----— i --- —------- - 1 -,- -----4------- T9 LEVEL 1 SLAB, SEE BUILDING STRUCTURAL DRAWINGS I FOR INFORMATION FIL COPY L — — —---------..... I a hr Permfit �■ L I I I Plan raview approval is subject to errors and omissions. TB TA.6 TA ,ppmval of construction documents does not authorize l f ti Manlift Foundation Plan Scale: 1/4" = V-0" BUILDING SLAB BUILDING WALL DOWELS EA FACE TC MATCH GRADE BM, DRILL AND EPDXY INTC DRAG WALL 6" MIN Section 4 Scale: 1/4" = V-0" TOP REINF ELEVA" DOWELS TO M/ GRADE BEAM V GRADE BEAM HORIZON PER ELEVA' Detail Scale: 1" = 1'-0" ur I xAD ren VAN 1 ST FLOOR 0' )E BEAM PER PLAN )E BEAM VERTS LEVATION #4 @ 16" OC MAX, DRILL & EPDXY INTO MANLIFT SLAB 6" EMBED LEVEL 1 SLAB NOTES: SEE 5/S3.202 & 9/S3.202 OF THE BUILDING STRUCTURAL DRAWINGS FOR REINF AT SLAB STEPS ,'� Detail Lu Scale: 1 1/2" = V-0" e vIt] a#Ion oany Adopte ode rdlnance. Receipt of approved Hold Cop Ion is n wledged: By: Date: `w..Iwrwr City of Tuila BUILDIItIG DIVISION MANLIFT SLAB 1st FLOOR 0'-0.. (4) #9 AT GRADE BEAM REN)(EWED FOR CODE COMPLiANCE APPROVED DEC o 2 2015 CIS of Tukwlia BUILDING DIVISIOi� OTE: OTALL REBAR SHOWN FOR CLARITY O O O O O O RECEIVED CITY OF TIJKWILA NOV 18 2015 PERMIT CENTER CURB TO BE PLACED AFTER MANLIFT REMOVAL (2) #4x CONT MANLIFT SLAB Lst FLOOR 0' -- 0" GRADE BEAM REINF PER ELEVATION GRADE BEAM ISSUE A Date Description 11/05/15 Construction Set SCALE: As indicated CHECKED BY: M. LUND APPROVED BY: DRAWN BY: KEYPLAN PHASE Construction Set PROJECT NUMBER LO NO. 14-050-02 PROJECT W LLJ I— W U Z IZ a- w Y �� 0 Q a� I- 0 > � rn V = o -0 � V) I— Z N co I--- LL QO� =Z Q CONSULTANT ` 4 SAIL 1201 First Avenue South, Suite 310 Seattle, Washin.gtori.98134 2W402-5156 www.lundopsahl.com REGISTRATION SHEET TITLE AND NUMBER MANLIFT FOUNDATION & TIE-INS S6 raL a�JL;t��„ n�sEtiu PLOTTED: 11/5/2015 2:10:44 PM NOTES: (� 1. SEE S1.0 FOR MANLIFT LOCATION Manlift Tie -In Plan - Levels 3. 6. 9. 12. 14. 17 and Lounge Level Scale: 1/4" = 1'-0" EMBED BRACKET BY OTHERS MAST BRACE BY OTHERS WALL BRACKET BY OTHERS NOTES: 1. LUND OPSAHL HAS ONLY DESIGNED THE SLAB TO RESIST LOADS PROVIDED BY MORROW. ALL PLATES, BOLTS, AND BRACKETS ARE DESIGNED BY OTHERS. Manlift Tie -In Reinf Scale: 1 1/2" = V-0" PT SLAB PER BUILDING STRUCTURAL DRAWINGS #4 U-BAR HOOKED AROUND EMBED BRACKET — T9 BUILDING STRUCTURAL DRAWINGS SECTION ----"-'"-- "3Y OTHERS) OTHERS) ;ACE _RS) T1 I ®18th FLOOR _ 167' - 0" ®17th_FLOOR _ 156'-4" 16th FLOOR ®15th FLOOR _ 138'-0" ®14th FLOOR _ 128' -10" ®13th FLOOR 119'-8" — ®12th FLOOR _ ®llth_FLOOR _ 101' - 4" ®loth FLOOR 92'_2-- ®9th FLOOR 83' _ 0" — ®8th FLOOR _ 73' -10" 7th FLOOR ®6th FLOOR _ 55' - 6' ®FLO Sth OR _ 46'-4' ®4th FLOOR 37' - 2'— — ®3rd FLOOR 28'-0" ®2nd FLOOR 14'_p"— ®1st FLOOR _ 61-- 01. I Manlift Elevation MANLIFT (BY OTHERS) MAST BRACE 7 (BY OTHERS) MAST BRACE 6 (BY OTHERS) MANLIFT MAST (BY OTHERS) MAST BRACE 5 (BY OTHERS) MAST BRACE 4 (BY OTHERS) MAST BRACE 3 (BY OTHERS) MAST BRACE 2 (BY OTHERS) MAST BRACE 1 (BY OTHERS) �ro>„ to � REV WED FOR 013E COMPLIANCE K ' APPROVED DEC 0 2 2015 city Of TuwlIa BUILDING DIVISION RECEIVED CITY OF IrVKWILA NOV 18 2015 PERMIT CENTER ISSUE A Date Description AN PHASE Construction Set PROJECT NUMBER FONO, 14-050-02 PROJECT W LIJ�_ (1) UZz <�w0 CL p W Z�� a� O<z L (� ` 0 -0 = z� LL N vJ LL QO� = z LTANT P :�ND SAHL 12111 First Avenue South, Sulle 310 Seattle, Washin.gton.98134 20G40M156. www.liindopsahl.c. om 'RATION SHEETTITLE AND NUMBER MANLIFT TIE-IN S7 PLOTTED: 11/5/2015 2:10:45 PM LTANT P :�ND SAHL 12111 First Avenue South, Sulle 310 Seattle, Washin.gton.98134 20G40M156. www.liindopsahl.c. om 'RATION SHEETTITLE AND NUMBER MANLIFT TIE-IN S7 PLOTTED: 11/5/2015 2:10:45 PM GENERAL NOTES CONTRACTS 1. ALL CONTRACTS SUPERCEDE ANY DEVIATIONS BETWEEN THIS DRAWING SET AND THE CONTRACT. 2. MORROW EQUIPMENT CO. L.L.C. REQUIRES A FULL REVIEW BY THE CONTRACTOR OF THE EQUIPMENT APPLICATION DETAILS AND PROCEDURES OUTLINED HEREIN TO DETERMINE IF ADJUSTMENTS ARE NEEDED TO ADHERE TO THE PROJECTS CONSTRUCTION METHODS, SCHEDULES, AND SITE CONDITIONS. VERIFICATIONS SHOULD BE MADE WELL IN ADVANCE OF THE ERECTION OF EQUIPMENT IN ORDER TO PREVENT ERECTION AND ANY RESULTING CONSTRUCTION DELAYS. MORROW EQUIPMENT CO. L.L.C. IS "NOT" RESPONSIBLE FOR PROJECT DELAYS DUE TO AN INABILITY TO ERECT CONSTRUCTION EQUIPMENT RESULTING FROM AN INCOMPLETE REVIEW OF THE EQUIPMENT APPLICATION. 3. CONFIRMATION IN WRITING TO MORROW EQUIPMENT CO. L.L.C.'S ENGINEERING DEPARTMENT IS REQUIRED FOR DRAWING SETS TO BE ISSUED "FOR CONSTRUCTION". UPON ERECTION OF EQUIPMENT, OR IF NO CONFIRMATION IS RECEIVED WITHIN 30 DAYS FROM THE ISSUE DATE, PRELIMINARY DRAWING SETS ARE ASSUMED TO BE CORRECT AND MAY BE ISSUED "FOR CONSTRUCTION". REQUESTS FOR REVISIONS TO THE DRAWING SETS MUST BE MADE IN WRITING TO MORROW EQUIPMENT COMPANY, L.L.C.'S ENGINEERING DEPARTMENT. REQUESTS FOR REVISIONS TO "FOR CONSTRUCTION" DRAWING SETS MAY BE BILLED AT CURRENT ENGINEERING RATES. 4. THESE DRAWINGS CONTAIN IDEAS, DESIGNS, ARRANGEMENTS, AND PLANS THAT WERE CREATED AND ARE TO BE USED ONLY FOR THE SPECIFIED PROJECT AND SITE, AND ARE OWNED BY AND THE PROPERTY OF MORROW EQUIPMENT COMPANY, L.L.C. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS, AND PLANS CONTAINED HEREIN ARE TO BE REPRODUCED OR COPIED IN WHOLE OR PART OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT EXPRESS WRITTEN PERMISSION. THESE DRAWINGS ARE TO BE RETURNED UPON REQUEST. 5. ALL PRELIMINARY DRAWINGS ARE FOR ILLUSTRATIVE PURPOSES ONLY. THEY ARE NOT INTENDED TO BE REPRESENTATIVE OF FINAL WORKING DRAWINGS. ALL HOOK HEIGHTS, NUMBER OF CLIMBS, CONFIGURATIONS, AND INVENTORY OF COMPONENT PIECES AND THEIR ACCESSORIES ARE SUBJECT TO CHANGE WITHOUT NOTICE. FOOTING 1. REFER TO THE HOIST BROCHURE PROVIDED BY MORROW EQUIPMENT COMPANY L.L.C. FOR DETAILS REGARDING THE FOOTING REQUIREMENTS AND RECOMMENDATIONS PROVIDED BY THE HOIST MANUFACTURER. REFER TO THE HOIST'S TECHNICAL DESCRIPTION MANUAL FOR INFORMATION NOT SHOWN IN THE BROCHURE OR IN THIS DRAWING SET. 2. WHEN ANCHORING THE BASE FRAME TO THE CONCRETE FOOTING WITH EXPANSION TYPE ANCHORS, THE FOLLOWING RESTRICTIONS APPLY: - THE MAXIMUM HEIGHT OF FIRST MAST BRACE IS 30 ft. (9m) PROVIDED THAT THE REDUCED ALLOWABLE ERECTION PAYLOAD OF 2,560 lb. (1 160kg) IS NOT EXCEEDED. - INSTALLATION IS PROHIBITED WHEN WIND SPEED IS IN EXCESS OF 12.5m/s (28mph). 3. THE EXPANSION ANCHORS MUST BE CAPABLE OF WITHSTANDING THE PULL OUT FORCE NOTED UNDER THE FOLLOWING CONDITIONS: - FREESTANDING IN SERVICE PULL OUT FORCE = 15,060 lb. (67kN) RECOMMENDED ANCHOR: 3/4" WILLIAMS R1S SPIN -LOCK ANCHOR PART NO. R1S06C14 HEAD ASSEMBLY WITH ASTM A1081C1045 BOLT AND NUT, DRILL HOLE 1 3/4" DIA. 11" MINIMUM EMBEDMENT. - FREESTANDING DURING ERECTION WITH ERECTION PAYLOAD NOT EXCEEDING 2,560 lb. (1 160kg) PULL OUT FORCE = 11,465 lb. (51kN) RECOMMENDED ANCHOR: 5/8" WILLIAMS R1 S SPIN -LOCK ANCHOR PART NO. R1 S05A10 HEAD ASSEMBLY WITH ASTM A108/C1045 BOLT AND NUT, DRILL HOLE 1 1/4" DIA. 8" MINIMUM EMBEDMENT. 4. THE ANCHOR PULL OUT REQUIREMENTS MAY BE REDUCED TO 8,450 lb. (37.6kN) IF THE FOLLOWING ERECTION PROCEDURE IS USED: - INCREASE THE COMPRESSIVE STRENGTH OF CONCRETE (f'c) FROM 3,625 psi TO 4,000 psi MINIMUM. - REDUCE THE ALLOWABLE ERECTION PAYLOAD TO 700 lb. (320kg). ERECTION PAYLOAD ASSUMES A PAYLOAD OF TWO PEOPLE AND ONE MAST BRACE WHILE THE MAST BRACE IS INSTALLED. - HOIST MAST MUST BE ASSEMBLED ON THE GROUND AND LIFTED IN PLACE WITH AN AUXILIARY CRANE. - AS A PRECAUTION, THE AUXILIARY CRANE MUST REMAIN ATTACHED TO THE HOIST MAST WHILE THE FIRST MAST BRACE IS INSTALLED. - ONE HOIST CAR MAY BE RAISED TO THE FIRST MAST BRACE ELEVATION WHILE THE HOIST MAST IS STILL ATTACHED TO THE AUXILIARY CRANE TO PROVIDE A WORK PLATFORM FOR THE MAST BRACE INSTALLATION. - RECOMMENDED ANCHOR: 1" x 12" HILTI KWIK BOLT 3. 7" MINIMUM EMBEDMENT. 5. THE ANCHOR RECOMMENDATIONS ARE NOT INTENDED FOR HOIST APPLICATIONS IN EXTREME COLD TEMPERATURES. PLEASE CONSULT MEC'S ENGINEERING DEPARTMENT FOR ANCHOR RECOMMENDATIONS FOR USE IN EXTREME COLD TEMPERATURES. 6. INSTALL EXPANSION ANCHORS ACCORDING TO BOLT MANUFACTURER'S REQUIREMENTS. ALIMAK BRAC MAST BRACT PIVOT POIN" ALIMAK 650 MAST SECTION POSITION 3 POSITION 2 POSITION 1 ALIMAK TYPE I, III, AND S3A MAST BRACE ATTACHMENT POSITIONS MAST BRACES 1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THAT THE STRUCTURE IS ADEQUATE TO RESIST THE HOIST'S REACTION FORCES PRIOR TO INSTALLATION OF THE MAST BRACES. 2. THE CONTRACTOR SHALL SUPPLY THE SPECIFIED BOLTS TO SECURE THE MAST BRACES TO THE STRUCTURE. a. DEFINITIONS: i SNUG -TIGHT - THE TIGHTNESS THAT IS ATTAINED WITH A FEW HITS OF AN IMPACT WRENCH OR THE FULL EFFORT OF AN IRONWORKER USING AN ORDINARY SPUD WRENCH TO BRING THE CONNECTED PLIES INTO FIRM CONTACT. ii FIRM CONTACT - THE CONNECTION THAT EXISTS ON A FAYING SURFACE WHEN THE PLIES ARE SOLIDLY SEATED AGAINST EACH OTHER, AT THE BOLTHOLE, BUT NOT NECESSARILY IN CONTINUOUS CONTACT ELSEWHERE. iii SLAB MOUNT - CONNECTING THE MAST BRACE WALL BRACKET TO A HORIZONTAL SURFACE. TYPICALLY A CONCRETE FLOOR SLAB. IV WALL MOUNT - CONNECTING THE MAST BRACE WALL BRACKET TO A VERTICALSURFACE. TYPICALLY THE FACE OF A CONCRETE FLOOR SLAB, WALL, OR BEAM. b. CONNECTION RECOMMENDATIONS: i SLAB MOUNT - BOLTS ARE TO BE INSTALLED SNUG -TIGHT THROUGH CONCRETE FLOORS IN STEEL SLEEVES OR WITH NON -SHRINK GROUT. ii WALL MOUNT - EMBEDMENT BRACKETS ARE RECOMMENDED FOR USE IN NEW CONSTRUCTION. EMBEDMENT BRACKETS ARE AVAILABLE FROM MEC OR MAY BE DESIGNED BY A PROFESSIONAL ENGINEER REGISTERED WITH THE LOCAL JURISDICTION. FOR EXISTING STRUCTURES, EXPANSION ANCHORS DESIGNED FOR USE IN CRACKED CONCRETE, SUCH AS THE HILTI HSL-3 HEAVY DUTY SLEEVE ANCHOR, ARE RECOMMENDED WITH CONSIDERATION OF SPACING AND EDGE DISTANCE BY USE OF STEEL MOUNTING PLATES. iii STRUCTURAL - INSTALL BOLTS PER TURN -OF -NUT PRETENSIONING METHOD STEEL PER "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS". C. INSPECTION: BOLTS ARE TO BE INSPECTED WEEKLY TO CHECK THAT THEY REMAIN SNUG TIGHT. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MAST BRACES BEING CORRECTLY AND SAFELY SECURED TO THE STRUCTURE. 4. MORROW EQUIPMENT COMPANY, L.L.C. SUPPLIES THE FOLLOWING EQUIPMENT: - WALL BRACKET - MAST BRACE COMPONENTS - MAST BRACKET - PINS & CIRCLIPS TO CONNECT MAST BRACE COMPONENTS - BOLTS TO CONNECT MAST BRACE COMPONENTS TO HOIST MAST 5. ALL OTHER EQUIPMENT AND MATERIALS REQUIRED FOR THE MAST BRACE INSTALLATION ARE TO BE SUPPLIED BY CONTRACTOR. 6. THE HOIST MAST MUST BE PLUMB WITHIN L/750 DURING THE INSTALLATION AND DISMANTLEMENT OF THE MAST BRACE. 7. THE CONTRACTOR MUST FIELD VERIFY THE DISTANCE FROM CENTERLINE OF THE HOIST MAST TO THE WALL BRACKET AT THE EXACT POINT OF CONNECTION PRIOR TO INSTALLING THE MAST BRACE. 8. THE CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF THE EQUIPMENT. 9. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THE EQUIPMENT INSTALLATION CONFORMS TO THIS DRAWING SET. 10. MAST BRACE FORCES RESULTING FROM HOIST OPERATION WITH WIND LOADING AND OUT OF SERVICE WIND LOADS ARE GIVEN IN THE DETAILS CONTAINED IN THE DRAWING SET. 11. MAST BRACE FORCES RESULTING FROM SEISMIC LOADING ARE TO BE EVALUATED BY THE ENGINEER OF RECORD FOR THE TIE-IN TO THE BUILDING STRUCTURE. SEISMIC COEFFICIENTS PER ASCE 7-05 ARE AS FOLLOWS: a. BASE SHEAR V=CsW (12.8-1) b. EFFECTIVE WEIGHT (W) PER EQUIPMENT BROCHURE. C. SEISMIC RESPONSE COEFFICIENT (Cs) IS FOR DESIGN SPECTRAL RESPONSE ACCELERATION IN THE SHORT PERIOD RANGE FOR MAXIMUM CONSIDERED EARTHQUAKE DETERMINED FROM SITE SPECIFIC GEOTECHNICAL REPORT AND SECTION 11.4. d. RESPONSE MODIFICATION FACTOR (R=3) TABLE (15.4.2) e. OCCUPANCY IMPORTANCE FACTOR (1=1) TABLE (11.5-1) f. SEISMIC LOAD EFFECT (E) PER SECTION 12.4.2. PLEASE NOTE THAT SEISMIC LOADS ARE AT THE STRENGTH LEVELS IN ASCE 7-05. BASIC LOAD COMBINATIONS FOR ALLOWABLE STRESS DESIGN ARE TO BE USED IN ORDER TO BE CONSISTENT WITH THE HOIST MANUFACTURER'S DESIGN STRESS LEVELS. g. THE MAST TIE-IN HORIZONTAL REACTION FORCES DERIVED FROM THE SEISMIC LOAD EFFECT SHOULD NOT EXCEED THE MAXIMUM VALUE GIVEN IN THE CONNECTION REACTION FORCES DIAGRAM CONTAINED IN THE DRAWING SET. IF THE HORIZONTAL REACTION FORCES ARE EXCEEDED THEN THE MAST'S CONFIGURATION WILL NEED TO BE EVALUATED BY MORROW'S ENGINEERING DEPARTMENT. ALIMAK FC 7100-12D SERIAL NUMBER: TBD DUAL CAR COMPONENTS QUANTITY 650 BASE MAST SECTION 1 650 MAST SECTION 39 TYPE S2A MAST BRACE 7 TYPE S3A ADAPTER PLATE 7 " UPPER CABLE GUIDE 6 MIDDLE CABLE GUIDE 1 LOWER CABLE GUIDE 6 CABLE TROLLEY GUIDE RAIL 6 0 3m CABLE TROLLEY GUIDE RAIL 1 COMPONENT CHART 1 ALIMAK FC 7100-12D EVIEWED FOR )E COMPLIANCE APPROVED DEC 0 2 2015 ® . .City OfTuw(lla BUILDING DIVISION 39 ROOF PLAN - EL. = 190'-0" LEVEL 20 - EL. = 187'-0" a� LAST LANDING 36 LOUNGE LEVEL - EL. = 177'-8" L = 7'-8" I 35 3/16" SHIM 34 18TH FLOOR - EL. = 167'-0" 33 32 17TH FLOOR - EL. = 156'-4" L = 7'-8 1/8 " 1/16" SHIM 30 16TH FLOOR - EL. = 147'-2" 29 28 15TH FLOOR - EL. = 138'-0" 27 A A-P 1_1 r-I f%-%M 1_ i _ A nnl A All 26 L = 7'-7 3/4 " 7/16" SHIM -' 13TH FLOOR - EL. = 119'-8" 24 23 12TH FLOOR - EL. = 110'-6" 22 L = 7'-7 5/8 " 5/8" SHIM 2T 11TH FLOOR - EL. = 101'-4" 20 19 10TH FLOOR - EL. = 92'-2" 18 17 9TH FLOOR - EL. = 83'-0" L = 7'-7 3/4 " I 7/16" SHIM 15 8TH FLOOR - EL. = 73'-10" 14 3m CABLE TROLLEY GUIDE RAIL----- 7TH FLOOR - EL. = 64'-8" 13 12 6TH FLOOR - EL. = 55'-6" 11 L = 7'-8 118 1/16" SHIM 5TH FLOOR - EL. = 46'-4" g 8 4TH FLOOR - EL. = 37'-2" 7 6 RD FLOOR - EL. = 28'-0" L = 7'-8 1/8 " 1/16" SHIM 2ND FLOOR - EL. = 14'-0" - FI = W_0" I MAST BRACE 7 ,L MAX. OVERHANG = 20'-3" 'r UP TO MAST SECTION 39 HOIST ACCESS UP TO LOUNGE LEVEL ATTACHMENT POSITION 3 MAST BRACE 6 MAX. OVERHANG = 17'-1 Y UP TO MAST SECTION 34 HOIST ACCESS UP TO 17TH FLOOR ATTACHMENT POSITION 2 2x UPPER ,, CABLE GUIDE (TYP) IT, G%a_0:L[f7A W, MAX. OVERHANG = 19'4" IV UP TO MAST SECTION 29 HOIST ACCESS UP TO 14TH FLOOR ATTACHMENT POSITION 1 MIDDLE CABLE GUIDE MAST BRACE 4 MAX. OVERHANG = 19'-4" UP TO MAST SECTION 25 HOIST ACCESS UP TO 12TH FLOOR ATTACHMENT POSITION 1 MAST BRACE 3 MAX. OVERHANG = 17'-l" UP TO MAST SECTION 19 HOIST ACCESS UP TO 9TH FLOOR ATTACHMENT POSITION 2 SEE DETAIL A (TYP. U.N.O.) 3 MAST BRACE 2 .L MAX. OVERHANG = 19'-4" 'r UP TO MAST SECTION 14 HOIST ACCESS UP TO 6TH FLOOR ATTACHMENT POSITION 1 LOWER CABLE GUIDE MAX. OVERHANG = 17'-1" 4 UP TO MAST SECTION 8 HOIST ACCESS UP TO 3RD FLOOR 3 ATTACHMENT POSITION 2 _ 2 1 1 ti ENTRY LEVEL M w 0 ti N r` N 0 N T ti N $tif.�s�:fd ��dfd kiu"�as'}5"�i�S Ss{st t f AY '���ittlto� N zfa� 42�J�f �� vL fs�sz�r� 3> d��zfd�ld� �GnVxtaxr, ,«z 10 0 co 0 W CV cn 0 a n o° 0 o m a, o a a� m C O Xa 0 Q Ocy a- a.V)0n0 O U O 0 E 0, rn N I� I� N C L 0� o t to c cry ch C 0 o N i- U_ W 0 U Z zW0 O 0 E- V -J Z vJ O vJ Z v O Z _ Ur=� vJ W` Y V) in m 0 v ir. sy: i cg. r GJS EB Title: GENERAL NOTES HOIST ELEVATION Issue Purpose: NOT FOR CONSTRUCTION PRELIMINARY ALT. "B" ti Date: N 10-16-15 Rev. Rev. Rev. Ck. No: I Date: I By: I By: STATIC LOADS BASE ENCLOSURE: 4.7 KIP HOIST CAR: 11.1 KIP PAYLOAD: 14.1 KIP MAST SECTIONS: 11.3 KIP SUB TOTAL OF STATIC LOADS: 41.2 KIP MAST TIES & CABLE GUIDES: 4.1 KIP TOTAL STATIC LOADS: 45.3 KIP DYNAMIC LOADS IMPACT ON MOVING PARTS: HOIST CAR: 11.1 KIP PAYLOAD: 14.1 KIP TOTAL DYNAMIC LOAD: 25.2 KIP FOOTING LOADS TOTAL LOAD ON FOOTING (STATIC + DYNAMIC): 70.5 KIP LOAD PER MAST LEG (CASE 1) - EMERGENCY STOP ON MAST: 16.5 KIP LOAD PER MAST LEG (CASE 11) - EMERGENCY STOP ON BUFFER: 3.9 KIP LOAD PER BUFFER (MAX.): 8.4 KIP I( IO z z IF IFy LL!a-la 0,m 0 U) Coiw c-Vjw L.L LL ILL I LL in iD m j �m I I 356mm I I I 711j I 178mm I IOF I I I � I I BUFFER SPRING _ _OF SPRING --------------- � I I � i ---------I -I- L OF_ BUF_FER _-------- ------------------- _- _--- I I o MAST LEG ---- ------------------- I j I ---- --1----I---- ---- ---- --- ----- ------- O_F ----- MAST OF ® I I I I - L-t-1 -- -- --_ ---_----------- _q _O_F_ _ ----- - c c- MAST LEG---- EE E N E w E C M E j I O E -- N �� E .- O N� O d W - rrn QO p T - I I I _ M CO L 04 I I CV U,__ N I -- -------------- -______ __�OF BUFFER SPRING � I I D 1'-0 3/4 �F v 325mm I D Q� I j 2'-1 5/8 " I j I_ 650mm I I I I I I I I I C7 I0 I IW W LLIJ LLLLI-J ,w j�- 0jIQ �I2 ula 12 1 I2 ALIMAK FC 7100-12D 9 PLAN VIEW OF BASE ENCLOS FIRST FLOOR SHOWN { 8 PtEVIEWED FOR - f DE COMPLIANCE n ; APP11OVED DEC 0 2 2015 !City of Tuhvila 'BUILDING DIVISION W O U Z ZWO p U I- CD 0 J o. Z Z ��M vJ O v, Z v O Z v=-J ry C/) 3: W < V i 3::D U) W Q 0 W v ur. by: / Get. by: GJS EB Title: FOOTING DETAILS Issue Purpose: NOT FOR CONSTRUCTION PRELIMINARY ALT. "B" Date: 10-16-15 Rev. Rev. Rev. Ck. No: Date: I By: I By: ANSI A' TO 2 1/ HOTS' SEE DI REBAR & ( (TO BE AF ENGINEER (BY COIN (BY CONTRACTOR) A ALIMAK TYPE S3A MAST BRACE CONN. 3 EDGE OF SLAB MOUNT EXAMPLE - SIDE VIEW CO �- REBAR & CONNECTION a M I— (TO BE APPROVED BY —� ENGINEER OF RECORD) (BY CONTRACTOR) SIDE VIEW 111 II. M 1 I. IZ IZ IZ IZ O O Oi0 10 10 c� Ica 1m -- ------------------------------------- -- -- TOP VIEW cV I I T 1 1/2" DIA. 3 13/16" 3'-3" (TYP.) 3'-11" (TYP.) EMBED BRACKE ALIMAK TYPE III NTS 3'-2 1/4" AFie= 1 -5 1/2 �� 890mm MAST BRACE FORCES CALCULATED ACCORDING TO EUROPEAN NORM EN 12159, 445mm WIND ZONE D ACCORDING TO THE METHODS z z DESCRIBED IN THE TECHNICAL DESCRIPTION MANUAL u- O U- O FOR THE ALIMAK FC 7100-12 DUAL CAR HOIST. c-0 E Ov � Ov �' � ill 4) SLOT026mm X M (TYP. 56m1m THE EQUIVALENT STATIC OUT -OF -SERVICE WIND VELOCITY = 100 mph (44.8 m/s) IE O O OF N � m CD _ _ ____ BOLT CONN _ _ _ I OF Rx 'C OF _ _ _ _� BOLT GROUP MAST BRACE FORCES B_ OLT —ONN. _ ---- ------ — -- ---- 7--- — --- — MAY ACT IN OPPOSITE & PIN CONN. - E P DIRECTION FROM M of Iw = OF 2-11 THAT SHOWN. jQ co E R MAST Y O I m �iQ r, co 00 P 0¢ Rx 12 rA1 1/4 ° (TYP. 2) 32mm C�2 Rx Ry P PLAN VIEW IN SERVICE 5.6 KIP 2.3 KIP 16.6 KIP OUT OF SERVICE 3.2 KIP 2.9 KIP 10.1 KIP MAXIMUM REACTION FORCES SHOWN = E E 1 C MAST BRACE FORCES N N 3 ALIMAK FC 7100-12D Z 'E S3A LL Z O OU .ACE C) z a 2 15/16 " 75mm SIDE VIEW B MOUNTING BRACKET 3 ALIMAK TYPE S3A ANSI A10.4 1 TO 2 1/2" (M HOIST CAI WALL (B) SEE FIRST FLOOR SHOWN I VtKll-Y ALL 1JIMtN51UN5� NORTH SCALE 0 1 2 4 8 R11 REWEWED FOR CODE COMPLIANCE APPROVED DEC 0 2 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 18 2�"5 PERMIT CENTER O C..) z zw0 OCUI- -<(D F -J C- z Dz= SOU) I- Q z (D O Z v=� O� U) W Q V U) W m a FA v Ir. ny: ux. ny: GJS EB Title: MAST BRACE DETAILS Issue Purpose: NOT FOR CONSTRUCTION PRELIMINARY ALT. "B" Date: 10-16-15 Rev. Rev. Rev. Ck. No: Date: By: I By: