Loading...
HomeMy WebLinkAboutPermit D15-0308 - T-MOBILE - WIRELESS COMMUNICATIONS FACILITY MODIFICATIONT=MOBILE 16400 SOUTHCENTER PKWY EXPIRED 04122117 Dl 5=0308 City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http;//www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 2623049021 Permit Number: D15-0308 Address: 16400 SOUTHCENTER PKWY BLDG Issue Date: 5/26/2016 Permit Expires On: 11/22/2016 Project Name: T-MOBILE Owner: Name: LEGACY PARTNERS COMMERCIAL Address: PO BOX 130639, CARLSBAD, WA, 92013 Contact Person: Name: COLIN ROBINSON Address: 8210154TH AVE NE, REDMOND, WA, 98052 Contractor: Name: LEGACY TELECOMMUNICATIONS INC Address: PO BOX 360, BURLEY, WA, 98322 License No: LEGACTIO05KD Lender: Name: Address: Phone: (425) 533-2665 Phone: (253) 858-0214 Expiration Date: 6/1/2017 DESCRIPTION OF WORK: MODIFY EXISTING WIRELESS COMMUNICATIONS FACILITY ON ROOFTOP. REMOVE 2 PANEL ANTENNAS, ADD 3 NEW PANEL ANTENNAS, ADD 1 FRIG RRU, ADD 1 FXFC RRU, ADD 6 DIPLEXERS, ADD 2 FSMF, 2 FBBC AND 2 ESMB WITHIN EXISTING CABINET. Project Valuation: $20,000.00 Fees Collected: $824.42 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Occupancy per IBC: U Electrical Service Provided by: TUKWILA Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channel ization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No/ - Permit Center Authorized Signature: - Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to a onditions attached to this permit. Signature: Date: Print Name: % l This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: Confirm the presence of a readily visible, labeled, accessible Emergency Power Off Switch for fire department emergency shutdown use. Install the EPO switch if not already existing. 8: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 9: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 10: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 1400 FIRE FINAL CITY OF TUKWILA Community Development Deparhnent • Public Works Department • Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. , ` 0 506 v Project No. Date Application Accepted: Date Application Expires: use CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 2623049021 Site Address: 16400 South Center PRICY Tukwila, WA 98188 Suite Number: roof Floor: roof Tenant Name: T-Mobile New Tenant: ❑ .....Yes L ..No PROPERTY OWNER Name: Radovich Properties, LLC Address: 2835 82nd Ave SE Suite S-1 City: Mercer Island State: WA Zip: 98040 CONTACT PERSON — person receiving all project communication Name: Colin Robinson Address: 8210 154th Ave NE City: Redmond State: WA Zip: 98052 Phone: (425) 533-2665 Fax: Email: Robinson@centerlinesolutions.com GENERAL CONTRACTOR INFORMATION Company Name: TBA Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: ARCHITECT OF RECORD Company Name: Vector Structural Engineers Architect Name: Roger Alworth, SE Address: 9138 S State Street Suite 101 City: Sandy State: UT Zip: 84070 Phone: (801) 990-1775 Fax: Email: ENGINEER OF RECORD Company Name: Vector Structural Engineers Engineer Name: Roger Alworth, SE Address: 9138 S State Street Suite 101 City: Sandy State: UT Zip: 84070 Phone: (801) 990-1775 Fax. Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: N/A Address: City: State: Zip: H:Wpplicatiots\Forns-Applications On Line\2011 ApplicationsTertnh Application Revised - 8-9-1I.docx Revised: August 2011 bh Pagel of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 20,000 Existing Building Valuation: Describe the scope of work (please provide detailed information): 20,000 Modify existing wireless communications facility on rooftop. Remove 2 panel antennas, add 3 new panel antennas, add 1 FRIG RRU, add 1 FXFC RRU, add 6 diplexers, add 2 FSMF, 2 FBBC and 1 ESMB within existing cabinet. Will there be new rack storage? ❑..... Yes O.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I' Floor 2 Floor P Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DMSION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? El ....... Yes m....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: El ....... Sprinklers ❑....... Automatic Fire Alarm .......None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ....... Yes Z .......No If "yes, attach list of materials and storage locations on a separate 8-112 " x II "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ ....... On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applicatiorts\Fomts-Applications On Line12011 Applications\P=it Application Revised - 8-9-11.do Revised: August 2011 Page 2 of 4 bh PUBLIC WORKS PERMIT INFOFcMATION — 206-433-0179 Scope of Work (please provide detailed information): Modify existing wireless communications facility on rooftop. Remove 2 panel antennas, add 3 new panel antennas, add 1 FRIG RRU, add 1 FXFC RRU, add 6 diplexers, add 2 FSMF, 2 FBBC and 1 ESMB within existing cabinet. Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila El...Water District #125 ❑ .. Highline El.. Renton ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila [:]...Valley View ❑ .. Renton ❑ .. Seattle ❑ ...Sewer Use Certificate ❑ ... Sewer Availability Provided Septic System: ❑ On -site Septic System —For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with ADDlication (mark boxes which RDE ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ ..Maintenance Agreement(s) ❑ ... Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ .. Right-of-way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection _ Irrigation Domestic Water ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line I ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size.. WO # ❑ ...Water Only Meter Size............ WO # ❑ ...Deduct Water Meter Size ❑ ...Sewer Main Extension.............Public ❑ Private ❑ ❑ ...Water Main Extension.............Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer Monthly Service Billing to: Name: Mailing Water Meter Refund/Billing: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: City State Zip Name: Day Telephone: Mailing Address: City State zip H:\Applicatiore\Fomis-Applications On Line\201 l ApplicationsTertnit Application Revised- 8-9-I l.docx Revised: August 2011 Page 3 of 4 bh PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNN R OR AUTHORIZED AGENT: Date: 12/11/2015 Print Name: Colin Robinson for T-Mobile Day Telephone: (425) 533-2665 Mailing Address: 8210 154th Ave NE Suite 120 Redmond WA 98052 City State Zip H:\Applicatioris\Fonrks-Applicafiorts On Une\2011 ApplicationsTemit Appliption Revised - 8-9-1 I.docx Revised: August 2011 bh Page 4 of 4 DESCRIPTIONS• PermitTRAK QUANTITY PAID $824.42 D15-0308 Address: 16400 SOUTHCENTER PKWY BLDG Apn: 2623049021 $824.42 DEVELOPMENT $800.30 PERMIT FEE R000.322.100.00.00 0.00 $482.30 PLAN CHECK FEE R000.345.830.00.00 0.00 $313.50 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $24.12 TECHNOLOGY FEE TOTALR6841 R000.322.900.04.00 0.00 $24.12 $824.42 Date Paid: Friday, December 11, 2015 Paid By: T-MOBILE Pay Method: CHECK 3213285 Printed: Friday, December 11, 2015 1:29 PM 1 of 1 rRWSYS7EM S INSPECTION RECORDK Retain a copy with permit Ibly--0 �� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: T e of Inspection: Address: Date Called: mveq Special Instructions: Date Wante a.m. !� Acp z c;;�-:s- Requeste ) / 1 Phone No: Approved per applicable codes. t� Corrections required prior to approval. IInspector: /�,4u, Iuate: 1'e belA I ❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fed must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit[�iS -D3�f� INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: asfLe- Ty of Inspection: / L Address: eyd —<w_f FW) Date Called: Special Instructions: a ted: a.m. iRl� O p kRequ ster. Phone No: Approved per applicable codes. W Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. - PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: T e of Inspection: Address: �` PYLH Date Called: Special Instructions: Date Wanted: / la g 'j p.m. Requester: Phone No: Approved per applicable codes. 11 Corrections required prior to approval. Inspector: Date: /� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD -7- _ c>3 l Retain a copy with permit 1 INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project;,.. rye O7 V, Type of Inspection: T ► A'J 11 L Address: D S , C Contact Person: Suite #: Special Instructions: Phone No.: proved per applicable codes. �� -Corrections required prior to approval. f COMMENTS: 41 D „ p0 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 4S- �} Date: Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. tsming Aaaress Attn: Company Name: Address: City: State: Zip: Word/Inspection-Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 ECTO E n G in E E R S Project Number: U1194-844-151 November 12, 2015 Cascadia PM, LLC 3320 South Bay Road NE Olympia, WA 98506 ATTENTION: Bryan Underhill REFERENCE Dear Bryan, REVIEWED FOR CODE COMPLIANCE APPROVED JAM 11 2016 City of Tukwila BUILDING DIVISION SE04000B — South Center Place Sector Split 16400 Southcenter Parkway — Tukwila, WA 98188 Structural Review of Proposed Antenna and Equipment Installation Per your request, we have reviewed the construction drawings prepared by your office for the proposed removal of (2) existing panel antennas and the installation of (3) new panel antennas, (2) RRUs, and (6) diplexers attached to new or existing antenna mounts on the wall of the existing penthouse. We have also reviewed a previous structural mount analysis by our office (Job No. U1194-582-151, Dated: March 27, 2015) and previous as -built antenna mount construction drawings prepared by PB Architects Seattle (Site Name: Southcenter Place; Dated June 14, 1998). In addition, we have reviewed the site walk photographs provided to us by your office. Please be advised as follows: Based upon our calculations and review of the documents noted above, we conclude that the antenna mounts, as shown on the attached construction drawings, are adequate to support the loads associated with the proposed antennas. Supporting calculations for the loading on the proposed equipment and an analysis of the antenna mounts and their connection to the existing building are attached. The loading associated with the proposed antennas and equipment is minor compared to the original loading on the existing structure and will not significantly affect the existing structure. The recommendations above are provided based upon calculations prepared by our office and information the client provided. A representative from Vector has not visited the site. The analysis and conclusions described above are based on the assumption that the structure was properly designed and constructed. Vector Structural Engineering makes no claim as to the correctness of the original design or the current condition of the structure, which is assumed to be in good condition, free of damage or deterioration. The contractor shall notify Vector immediately should any damage, deterioration or discrepancies between the as -built condition of the existing structure and the assume condition described in this report and on the construction drawings be found. We hope this meets your needs. If you have any further questions regarding this matter, please call this office at your convenience. n A--'& r.. T Very truly yours, VECTOR STRUCTURAL ENGINEERING Roger T. Alworth, S.E. RECEIVED Principal CITY OF TUKWILA w RTA/Irg DEC � � 2015 11/11/15 EXP.1/27/16 Enclosures PERMIT CENTER 9138 S. State St., Suite 101 / Sandy, UT 84070 / T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com D [S7,-w 0 3PO 0 Page 2 of 18 CT® JOB N : 14-151 DESIGNED: LRG EDATE: 1 : 1/12/1512/15 CHECKED: BDV E rl G I fl E E R S PROJECT: SE04000B SOUTH CENTER PLACE - SECTOR SPLIT Design Criteria: Code: Structural design is based on the International Building Code, 2012 Edition Wind: Basic wind speed = 110 mph (3-second gust) per the ASCE 7-10 standard Risk category: II Wind exposure: C Seismic: Seismic loads are based on the International Building Code, 2012 Edition Seismic importance factor, I = 1 Risk category: II Mapped spectral response accelerations: Ss = 1.455g S, = 0.542g Site class: D Spectral response coefficients: Sps = 0.97g Sol = 0.542g Seismic design category: D Basic seismic -force -resisting -system: Appendages and Ornamentations Seismic response coefficient, Cs = 0.388 Response modification factor, R = 2.5 Analysis procedure: Equivalent lateral force General Notes: 1 The contractor shall verify dimensions, conditions and elevations before starting work. The engineer shall be notified immediately if any discrepancies are found. 2 The typical notes and details shall apply in all cases unless specifically detailed elsewhere. Where no detail is shown, the construction shall be as shown for other similar work and as required by the building code. 3 These calculations are limited to the structural members shown in these calculations only. 4 The contractor shall be responsible for compliance with local construction safety orders. Approval of shop drawings by the architect or structural engineer shall not be construed as accepting this responsibility. 5 All structural framing members shall be adequately shored and braced during erection and until full lateral and vertical support is provided by adjoining members. Structural Steel: 1 All structural steel code checks based on the AISC, 13th Edition per the ASCE 7 standard 2 All steel pipe to be per ASTM A53 GR. B (35 KSI), U.N.O. 3 All other structural steel shapes & plates shall be per ASTM A36, U.N.O. 4 All bolts for steel -to -steel connections shall be per ASTM A325N, U.N.O. 5 All bolted connections shall be tightened per the "turn -of -nut" method as defined by AISC. 6 All welding shall be performed by certified welders in accordance with the latest edition of the American Welding Society (AWS) D1.1 7 All steel surfaces shall be galvanized in accordance with the ASTM A123 and ASTM A153 standards, U.N.O. 0 Page 3 of 18 OJOB NO.: U119 151 DESIGNED: LRG 0 DATE: 11/12/1/12/15 CHECKED: BDV E n G I n E E R S PROJECT: SE04000B SOUTH CENTER PLACE - SECTOR SPLIT SUBJECT: Wind Calculations Com onents and Cladding Wind Calculations Label: Antenna Wind Load Note: Calculations per ASCE 7-10 SITE -SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]: 110 Notes: Exposure Category: C Importance Factor, I: 1.00 ADDITIONAL INPUT & CALCULATIONS: Height of roof, h [ft]: 78.8 Comp/Cladding Location: h > 60 ft: Enclosure Classification: Enclosed Buildings GCP: 1.8 Figure 30.6-1 a: 9.5 Table 26.9-1 z9 [ft]: 900 Table 26.9-1 Kh: 1.204 Table 27.3-1 KI: Figure 26.8-1 K2: Figure 26.8-1 K3: Figure 26.8-1 Krt: 1 Equation 26.8-1 Kd: 0.85 Table 26.6-1 Velocity Pressure, qh [psf]: 31.69 Equation 30.3-1 GCP;: 0.18 Table 26.11-1 (enter largest abs. value) (leave blank for negligible topographic effects) (leave blank for negligible topographic effects) (leave blank for negligible topographic effects) (largest abs. value) OUTPUT: Full Wind Pressure (1.0), p [psf]: 62.75 psf GCGCP p = q,, P - Design Wind Pressure (0.6), p [psf]: 37.65 psf Page 4 of 18 Label: JOB NO.: 1 1 12/2014-151 DESIGNED: LRG DATE: 11/12/2015 CHECKED: BDV ECTOR PROJECT: SE04000B South Center Place - Sector Split SUBJECT: LOADS Single Antenna Mount Antenna Equipment: Point Loads Weight Front Side Wind Forces 1.0 Seismic Forces 1.0 Front load Side load Lateral Vertical Quantity Ibs area(ft) area ft') (Ibs) (Ibs) (Ibs) (Ibs (N) DBXNH-6565E-A2M 46.3 1 6.01 3.58 377 225 53.9 9.0 (N) FRIG 59.9 1 2.85 1.24 179 78 69.7 11.6 (N) Diplexers (3 together) 23.7 1 0.41 0.39 26 24 27.6 4.6 Line Loads Weight Ibs Length ft Dia or Width in Weight I Wind Forces 1.0 I Seismic Forces 1.0 I 2" STD Steel Pipe 47 13.0 2.38 3.65 7.5 7.5 4.3 0.7 Dead Load, D: Total Weight of Components: Wp = 177 lb Wind Load, W: Design Wind Pressure: p = 62.8 psf (1.0W) Vtrans = 608 lb 0.6 * Vtrans_ 365 lb Viong = 424 lb 0.6 * Viong - 254 lb Seismic Load, E: Consider Seismic: Yes Occupancy Category: II Fa = 1.0 Seismic Design Category: D Fv = 1.5 Ip = 1.00 SMS = 1.455 Site Class: D SMi = 0.813 RP = 2.5 SDS = 0.970 SS = 1.455 SDI = 0.542 St ap = 2.5 0.7 * Fp,min = 36 Ib Z = 1.0 ft 0.7 * Fp,max = 193 Ib h = 1.0 ft z/h = 1.0 0.7 * Fp,aans =1 145 Ilb 0.7 * Fpjong = 145 lb Fp, lateral = 1.164 Fp, vertical = 0.194 0.7 * Fp,vert = 24 lb Wind Controls Wind Controls Page 5 of 18 Y Z X Vector Structural Engineers SK - 1 LRG Antenna Mount Nov 11, 2015 at 4:41 PM U1194-844-151 Antenna Pipe.r3d Page 6 of 18 Y A� Z X 7 L 4 5 6 3 Cl) 2 >TA? 2 1 0 Vector Structural Engineers SK - 2 LRG Antenna Mount Nov 11, 2015 at 4:41 PM U1194-844-151 Antenna Pipe.r3d Page 7 of 18 Loads: BLC 1, Dead Vector Structural Engineers LRG U 1194-844-151 -23.1 -59. -23. -23.1 Antenna Mount SK-3 Nov 11, 2015 at 4:42 PM Antenna Pipe.r3d Page 8 of 18 Y Z X 188.51b 178.91b 188.51b 25.81b 10 7.51b/ft Loads: BLC 2, WLx Vector Structural Engineers SK - 4 LRG Antenna Mount Nov 11, 2015 at 4:42 PM U1194-844-151 Antenna Pipe.r3d Page 9 of 18 Y Z X 112.51b i 77.81b i .21b 112.51b i 2�07. i i i 51b/ft Loads: BLC 3, WLz Vector Structural Engineers SK - 5 LRG Antenna Mount Nov 11, 2015 at 4:42 PM U1194-844-151 Antenna Pipe.r3d Page 10 of 18 Y Code Check ( Env) No Calc > 1.0 Z X .90-1.0 .75-.90 .50-.75 0-50 0 v Member Code Checks Displayed (Enveloped) Results for LC 1, DL Vector Structural Engineers SK - 6 LRG Antenna Mount Nov 11, 2015 at 4:42 PM U1194-844-151 Antenna Pipe.r3d Page 11 of 18 Company Vector Structural Engineers Nov 11, 2015 Designer LRG Job Number U1 94-844-151 Checked By: BDV IIIRISAModel Name Antenna Mount Hot Rolled Steel Properties 1 . KM C UL ;l r] nL ;l Aln Therm A4 nene;f..fL /pAZI V;e1dfL..;l M, G.nL ;l 06 1 A36 Gr.36 29000 11154 .3 .65 .49 36 1.5 58 1.2 2 A572 Gr.50 29000 11154 .3 .65 .49 50 1.1 65 1.1 3 A992 29000 11154 .3 .65 .49 50 1.1 65 1.1 4 A500 Gr.42 29000 11154 .3 .65 .49 42 1.4 58 1.3 5 A500 Gr.46 29000 11154 .3 .65 .49 46 1.4 58 1.3 6 A53 Gr. B 29000 1 11154 1 .3 .65 .49 35 1.5 1 60 1.2 Hot Rolled Steel Section Sets I hn1 Chinn Tune nec;nn I rl-;nn A r;n91 1- r;nAl h. r;nAl 1 r;nAt 1 MountPi a PIPE 3.0 IBearn Pie I A53 Gr. B I TvDlcal 1 2.07 1 2.85 2.85 5.69 2 Outrigger Bracket Igeaml RECT I A500 Gr.46 I Typical 12.938 14.507 110.5751 .061 3 Angle L4x4x4 I Beam I RECT I A36 Gr.36 ITypicall 1.93 1 3 1 3 1 .044 Member Primary Data I Ohel I _Inint I .Ininf K _Ininf Rntnfe/rl T.mo rl-inn 1 ie4 11A.fnrinl nncinn Rnl 1 M1 N9 N2 Outrigger I Be- -am I RECT IA500 Gr.461 TvDical 2 M2 N8 I N1 Outrigger IQearnI RECT 1650OGr.461 Typical 3 M3 NO I N7 MountPi a I Beam I Pie I A53 Gr. B I Tvnical Joint Coordinates and Temperatures 1 �hnl Y rffl v rai 7 U41 T­ rm nnf-h Crnm rl Basic Load Cases BLC Description Cate o X Gravitv Y Gravitv Z Gravitv Joint Point Distribut..Area M... Surface... Dead I DL -1 4 3 1 WLz I WLZ 4 1 1 1 Load Combinations nnenrinfinn C RISA-3D Version 13.0.1 [NA ... \...\...\... \ENG\Antenna Pipe.r3d] Page 1 Page 12 of 18 Company Vector Structural Engineers Nov 11, 2015 Designer IIIRISAMod Job Number : U1 94-844-151 Checked By: BDV el NameAntenna Mount Load Combinations (Continued) f�e�...;..ti.... C Dr%c14 � C Q C� IN MORIBIRTIMM, M. Envelope RISC 14th(360-10) LRFD Steel Code Checks 1111—k— ek— PA. Pk—t, I n I Izk.— (`Ln I n I nL.;*On nLi*Dn nl.;*nnn ., nLi*nnn Cnn 1 M1 I Bracket 1 .160 .5 12 .060 0 5 57701 ... 2161 ... 8072.461 6550.2..1. H1-lb 2 M2 Bracket .159 .5 13 .059 0 4 57701... 12161... 8072.461 6550.2.. 1..H1-1b 3 M3 PIPE 3.0 .405 .8814 .052 .74 6 58506... 65205 5748.755748.751..H1-1b Envelope Joint Reactions WM Y rlhl I (: V rlhl I (` 7 nhl I (` MY rlh-Al I (: MV nh-Rl I (` M7 rn%-m I f` 1_ N8 max 978.825 4 2213.776 4 588.675 1 2 0 1 259.345 3 0 1 2 min -903.54 13 -2028.352 13 -588.675 3 0 1-259.345 2 0 1 3 N9 max 1284.06 13 2221.325 5 844.5 3 0 1 387,252 2 0 1_ 4_ min -1359.345 4 -2022.803 12 -844.5 2 0 1-387.252 3 0 1 5 Totals: max 380.52 5 233.225 5 255.825 11 6 min -380.52 1 12 139.935 1 12 -255.825 10 RISA-31D Version 13.0.1 [NA ... \...\...\... \ENGWntenna Pipe.r3d] Page 2 r Page 13 of 18 ��il'ii1-z•�►� Anchor Designer TM .�; Software `- Version 2.3.5365.0 1.Proiect information Customer company: Cascadia Customer contact name: Customer e-mail: Comment: 2. Input Data & Anchor Parameters General Design method:ACI 318-11 Units: Imperial units Anchor Information: Anchor type: Bonded anchor Material: F1554 Grade 36 Diameter (inch): 0.500 Effective Embedment depth, her (inch): 4.000 Code report: ICC-ES ESR-3372 Anchor category: - Anchor ductility: Yes hmin (Inch): 6.50 cagy (inch): 3.65 Cmin (inch): 1.75 Smin (inch): 3.00 Load and Geometry Load factor source: ACI 318 Section 9.2 Load combination: not set Seismic design: No Anchors subjected to sustained tension: No Apply entire shear load at front row: No Anchors only resisting wind and/or seismic loads: No <Figure 1> Company: VSE Date: 11/11/2015 Engineer: LRG Page: 1/4 Project: South Center Place Address: Phone: E-mail: 1360 Ib Project description: Location: Fastening description: Base Material Concrete: Normal -weight Concrete thickness, h (inch): 10.00 State: Cracked Compressive strength, fc (psi): 3000 qj<,v: 1.0 Reinforcement condition: B tension, B shear Supplemental reinforcement: Not applicable Do not evaluate concrete breakout in tension: No Do not evaluate concrete breakout in shear: No Hole condition: Dry concrete Inspection: Continuous Temperature range: 2 Ignore Edo requirement: Not applicable Build-up grout pad: No Base Plate Length x Width x Thickness (inch): 8.00 x 8.00 x 0.44 22221b � _'-Y 260 ft-lb Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongbe.com Page 14 of 18 -7i►�ir�.�•�c■ Anchor Designer TM Software Version 2.3.5365.0 <Figure 2> Recommended Anchor Anchor Name: ET-HPTm - ET -HP w/ 1/2"0 F1554 Gr. 36 Code Report Listing: ICC-ES ESR-3372 Company: VSE Date: 11/11/2015 Engineer: LRG Page: 2/4 Project: South Center Place Address: Phone: E-mail: Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Page 15 of 18 E7iI'ii:�.�•�►� Anchor DesignerT"' Software Version 2.3.5365.0 Company: VSE Date: 11/11/2015 Engineer: LRG Page: 1314 Project: South Center Place Address: Phone: E-mail: 3._Resultina Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, Nua (lb) Vuax (lb) Vuay (lb) J(Vuaz)2+(Vuay)2 (lb) 1 599.4 147.3 555.5 574.7 2 599.4 147.3 555.5 574.7 3 81.1 147.3 555.5 574.7 4 81.1 147.3 555.5 574.7 Sum 1361.2 589.0 2222.0 2298.7 Maximum concrete compression strain (%o): 0.00 <Figure 3> Maximum concrete compression stress (psi): 5 Resultant tension force (lb): 1361 Resultant compression force (lb): 1 Eccentricity of resultant tension forces in x-axis, e'NX (inch): 2.28 Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00 Eccentricity of resultant shear forces in x-axis, e'vx (inch): 0.00 Eccentricity of resultant shear forces in y-axis, e'vy (inch): 0.00 01 02 Y X 04 03 4. Steel Strenath_of Anchor in Tension(Sec, D.5.11 Nse (lb) 0 ON.. (lb) 8235 0.75 6176 ,5._Concrete- Breakout Strencith of Anchor in Tension (Sec, D.5.21 Nb = kcAaJfchet'-`' (Eq. D-6) kc Aa f. (psi) het (in) Nb (lb) 17.0 1.00 3000 4.000 7449 ONcbg =O (ANcIANm)VecN'Fed,NWc,NWcp,NNb (Sec. D.4.1 & Eq. D-4) ANc (in2) AN- (InZ) 'Fe c,N %d,N Tc,N Vcp,N Nb (lb) 0 ONcbg (lb) 288.00 144.00 0.724 0.900 1.00 1.000 7449 0.65 6312 S. Adhesive Streni skcr = tkafshort-te=Ksat Zk,a (psi) fshorRtemr Ksat Zk,a (psi) 200 1.00 1.00 200 Nba = A azamiahet(Eq. D-22) A a Za (psi) da (in) het (in) Nb. (lb) 1.00 200 0.50 4.000 1257 ONag = 0 (ANalANaO)TecNBWedNa'Fcp,NeNba (Sec. D.4.1 & Eq. D-19) ANa (in2) ANao (InZ) Iec Ne 'Ped,Na Tcp,Na Nba(Ib) 0 ONag (lb) 140.00 35.00 0.564 1.000 1.000 1257 0.65 1843 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Page 16 of 18 Itti7n�n�.z��►� Anchor Designer TM Software Version 2.3.5365.0 8. Steel Strength of Anchor in Shear (Sec. D.6,11 Vsa (lb) Ogrout 0 QgroutoVsa (lb) 4940 1.0 0.65 3211 Company: VSE Date: 11/11/2015 Engineer: LRG Page: 4/4 Project: South Center Place Address: Phone: E-mail: 9. Concrete Breakout Strength of Anchor in Shear (Sec. D.6.21 Shear parallel to edge in x-direction: Vby = minl7(/e/da)024daA.4fcca11-5; 9Aa4fccal"51 (Eq. D-33 & Eq. D-34) la (in) da (in) ,ta fc (psi) cal (in) Vby (lb) 4.00 0.50 1.00 3000 4.00 3287 OWbgx = 0 (2)(Avc/Avco)Tec,vY'edvVc,v'Yb,vVby (Sec. D.4.1 & Eq. D-31) Avc (in2) Avco (in2) 'Yec,v Y'ed,v Y'c,v Y'b,v Vby (lb) 0 r6Vcbgx (lb) 108.00 72.00 1.000 1.000 1.000 1.000 3287 0.70 6904 10. Concrete Prvout Strength of Anchor in Shear (Sec. D.6.31 OVcpg = O minikc^g ; kcpNcbgl = o mmlkcp(ANa/AN.0)�'ec,NaYued,NaYop,NaNba; kcp(ANc/ANco)V'e ,NYyedNPc,NTcp,NNbl (Eq. D-41) kcp AN. (in2) ANao (in') WedNa P-,Na Yop,Na Nba (lb) Na (I b) 2.0 140.00 35.00 1.000 1.000 1.000 1257 5027 ANc (in') AN- (in2) %.,N Yxed,N KN Yucp,N Nb (lb) Ncb (lb) 0 288.00 144.00 1.000 0.900 1.000 1.000 7449 13408 0.70 OVcpg (lb) 7037 11. Results Interaction of -Tensile and Shear Forces (Sec, DM Tension Factored Load, Nua (lb) Design Strength, oNn (lb) Ratio Status Steel 599 6176 0.10 Pass Concrete breakout 1361 6312 0.22 Pass Adhesive 1361 1843 0.74 Pass (Governs) Shear Factored Load, Vua (lb) Design Strength, oW (lb) Ratio Status Steel 575 3211 0.18 Pass 11 Concrete breakout y- 294 6904 0.04 Pass Pryout 2299 7037 0.33 Pass (Governs) Interaction check N.WOM Vua/Oyb Combined Ratio Permissible Status Sec. D.7.3 0.74 0.33 106.5 % 1.2 Pass ET -HP w/ 1/2"0 F1564 Gr. 36 with hef = 4.000 inch meets the selected design criteria. 12, Warninas - Designer must exercise own judgement to determine if this design is suitable. - Refer to manufacturer's product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Page 17 of 18 L%TC IIVIIN DSPEED BY LOCATION Applied Technology Council Search Results Latitude: 47.4555 Longitude:-122.2615 ASCE 7-10 Wind Speeds (3-sec peak gust MPH*): Risk Category I: 100 Risk Category II: 110 Risk Category III -IV: 115 MRI** 10 Year: 72 MRI** 25 Year: 79 MRI** 50 Year: 85 MRI** 100 Year: 91 ASCE 7-05: 85 ASCE 7-93: 70 eMPH(Miles per hour) "MRI Mean Recurrence Interval (years) Users should consuIVAth local building officials to determine if there are community -specific wind speed requirements that govern. .4 \ ! Iv white Center Cw WMoun_ Nepionll w, -d P!r! Last ften,rn r't� N_' Renton Ihghle,Mc 0 Veehon � s<nre� Nome, . Or,ll,a Perk J ,slend -P,irtnpe OnM.— r o eland North Caxedermnwod tact r.,� ` I1,11•Mmd,en ` ' o ` LMe Morton-ee„vda: . Map Otte SOow/e WIND SPEED WEB SITE DISCLAIMER: While the information presented on this web site is believed to be correct, ATC assumes no responsibility or liability for its accuracy. The material presented in the wind speed report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the wind speed report provided by this web site. Users of the information from this web site assume all liability arising from such use. Use of the output of this web site does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site(s) described by latitude/longitude location in the wind speed report. Sponsored by the ATC Endowment Fund Applied Technology Council 201 Redwood Shores Parkway, Suite 240 Redwood City, California 94065 (650) 595-1542 Design Maps Summary Report Page 1 of 1 Page 18 of 18 -MW Design Maps Summary Report User —Specified Input Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.455380N, 122.26153°W Site Soil Classification Site Class D — "Stiff Soil" Risk Category I/II/III P mapquest USGS—Provided Output c < t°n De Moines 00 �02 S MvQuest S nton 7_NORTH A M E R I C A 0201541)p '1 ® MapQuest Ss = 1.455 g SMs = 1.455 g Sus = 0.970 g S, = 0.542 g SM, = 0.814 g So, = 0.542 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCEa Response Spectrum 1.55 1.s0 1 i5 1,20 1 OS w C� 0 TO (AA 0 75 0 c0 0 45 0-20 0-15 0 00 00 0.20 0.40 0.90 0.0 1.00 1.20 1.40 1.60 1.80 2.00 Period, i (sac) Design Response Spectrum 1.10 1.00 050 0-20 070 o so 0_.0 w 0-40 0 20 0 20 0 10 0 ao 0.02 0.20 0.40 0.60 0.V3 Leo 1.20 1.40 1-90 1.s0 2.00 Period, T (sec) Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. http://ehp4-earthquake.cr.usgs.gov/designmaps/us/summary. php?template=minimal& latitu... 5/27/2015 DocuSign Envelope ID: FFFB7C8C-9AA7-47A6-BD66-96B3A057323D .#4 4: T-Mobile USA, Inc. T m aM b i2920 , Street O 1le 0 Bellevue, WA 98006 Attn: Lease Compliance/SE03999A & SE04000B October 13 ,2017 City of Tukwila 6300 Southcenter Boulevard, Suite 9100 Tukwila, WA 98188 Re: Wireless Telecommunication Facilities Permit: L15-0059 Address: 16400 Southcenter Parkway, Tukwila, WA 98188 ("South Center Place") Wireless Telecommunication Facilities Permit: L16-0053 Address: 15215 52°d Avenue South, Tukwila, WA 98188 ("Parkridge") Dear City of Tukwila, in � E VED- ACT 14 2017 Community Development This letter is in reference to two wireless permits obtained by Centerline Solutions ("Centerline") on behalf of T-Mobile West LLC ("T-Mobile"). Centerline applied for wireless telecommunication facilities permits ("Wireless Permits") to modify existing cell sites at South Center Place and Parkridge. A Type 11 Wireless Telecommunications Facilities Permit was approved by the Department of Community Development (the "Department") on January 21, 2016 under the project number L15-0059 for South Center Place. The corresponding building permit number, D15-0308, was issued on May 26, 2016. A Type I Wireless Telecommunications Facilities Permit was approved by the Department on November 22, 2016 under the project number L16-0053 for Parkridge. The corresponding building permit number, D16-0251, was issued on April 17, 2017. The Wireless Permits and the building permit for South Center Place contained a condition that an emergency power off ("EPO") switch must be installed at the site. The Wireless Permit for Parkridge also indicated that "an emergency power shut down switch is required for antennae system for fire department use in event of a building fire." The initial interpretation of the requirement of an EPO switch by the Department and Tukwila Fire Department (collectively, "Tukwila") was the ability to sever the local AC commercial power to prevent electrical hazards in the event of a fire. After completion of the modification to South Center Place, T-Mobile contractors scheduled an inspection with the City of Tukwila to close D15-0308. When the Tukwila Fire Department inspected the site on October 24, 2016, the inspection failed because an EPO switch was not installed. At that time, the contractors and Centerline learned that the Tukwila Fire Department requires the installation of a "readily visible, labeled, accessible" EPO switch shutting down all power and communication at a cell site, and not solely AC commercial power, due to concerns over emergency responder exposure to radiofrequency electromagnetic radiation ("RF Exposure"). The Federal Communications Commission ("FCC") established guidelines for RF exposure and published OET Bulletin No. 65 ("OET-65") which provides guidance on evaluating compliance with FCC policies and guidelines related to RF Exposure. The FCC's guidelines for RF exposure incorporate two tiers of limits, one for general public exposure and one for situations usually involving workers, termed "occupational/controlled" exposure. Antenna installations on building rooftops fall into the latter limit when members outside the general DocuSign Envelope ID: FFFB7CBC-9AA7-47A6-BD66-96B3A057323D -9 public enter the rooftop space. T-Mobile regularly conducts testing and takes measurements to ensure compliance with FCC guidelines as described in OET-65. T-Mobile, along with other communications providers, play an essential role in the delivery of public safety services, particularly 911 services, and that role is especially prominent during emergencies that lead to power outages. 80 Fed. Reg. 62470. Pursuant to federal regulations promulgated by the FCC, certain communications providers, such as T-Mobile, must reliably provide 911 callers the ability to connect to a Public Safety Answering Point ("PSAP") or appropriate local emergency authority. 47 C.F.R. §20.18. Furthermore, providers of 911 services must have the ability to provide the location of the caller. id. T-Mobile's South Center Place and Parkridge sites are equipped with enhanced 911 capabilities. The reliability of this public safety service is dependent on the ability of these sites to transmit and receive information from mobile devices at all times, including commercial power outages. T-Mobile, being a covered 911 service provider, is required to "certify whether it ... provisions backup power through fixed generators, portable generators, batteries [emphasis added], fuel cells, or a combination of these or other such sources to maintain full -service functionality, including network monitoring capabilities, for at least 24 hours at full office load...," 47 C.F.R. §12.4. T-Mobile has installed batteries at these sites to ensure its compliance with federal regulations. Furthermore, providers of "facilities -based, fixed voice service" are required to offer new voice subscribers the option to purchase standby backup power solutions. 47 C.F.R. § 12.5. Collectively, these federal regulations underscore the importance of an uninterruptible power supply to ensure 911 services will continue to operate during power outages. Tukwila's requirement to install an EPO switch enables the Tukwila Fire Department, or any other person having access to the EPO switch, to power down T-Mobile's equipment, including its antennas, thereby compromising T-Mobile's ability to ensure delivery of reliable 911 services in emergencies, as required by federal regulation. Additionally, a more immediate need exists to connect individuals to a PSAP during emergencies, including building fires, and shutting down T-Mobile's equipment would undoubtedly impair T-Mobile's ability to meet the need of the Tukwila community during such emergencies. T-Mobile has reviewed the Tukwila Zoning Ordinance, Tukwila's Fire Code (adopted from the International Fire Code), the Washington State Building Code, and the Washington State Energy Code, and T- Mobile is unable to locate a section that requires an EPO switch be installed at wireless communication facilities. Therefore, it does not appear that State or local law require the installation of an EPO switch for wireless communications equipment. It is T-Mobile's position that Tukwila's requirement to install an EPO switch in order to power down T- Mobile's antennas and associated equipment during building fires is inconsistent with federal laws and regulations governing covered 911 service providers. T-Mobile, as a covered 911 service provider, respectfully requests the removal of this requirement from the Wireless Permits and/or building permits for the South Center Place and Parkridge cell sites. The safety of the members of Tukwila's Fire Department and the public are important to T- Mobile, as are T-Mobile's compliance with federal laws/regulations and its role in maintaining network reliability and public safety communications. T-Mobile welcomes the opportunity to further discuss this requirement and its prevalence on all Tukwila Wireless Permits and building permits for these facilities. T-Mobile appreciates the continued dialogue on finding a resolution to this permit condition. Please utilize the below contact information to further discuss this matter. Respectfully, 'cu'on''Y' BDOACDA3402249E... Print Name: Maria Emig Title: Development Manager , T-Mobile West LLC Email: maria.emig@t-mobile.com �;L Phone Number: F� . 425-398-7614 �wo1u tit c m, -US Date: 2017.10.12 O B3656 -WW City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 3/1/2017 COLIN ROBINSON 8210 154TH AVE NE - SUITE 120 REDMOND, WA 98052 RE: Permit No. D 15-0308 T-MOBILE 16400 SOUTHCENTER PKWY Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit.will expire on 4/22/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/22/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D15-0308 6300 Southcenter Boulevard Suite #100 e Tukwila, Washington 98188 • Phone 206-431-3670 9 Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 10/3/2016 COLIN ROBINSON 8210 154TH AVE NE REDMOND, WA 98052 RE: Permit No. D 15-0308 T-MOBILE 16400 SOUTHCENTER PKWY Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/22/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/22/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D15-0308 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 QDCity of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 5/13/2016 COLIN ROBINSON 8210 154TH AVE NE REDMOND, WA 98052 RE: Permit Application No. D15-0308 T-MOBILE 16400 SOUTHCENTER PKWY Dear COLIN ROBINSON, In reviewing our current application files, it appears that your permit applied for on 12/11/2015, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 6/11/2016. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D15-0308 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-0308 PROJECT NAME: T-MOBILE DATE: 12/11/15 SITE ADDRESS: 16400 SOUTHCENTER PKWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Fire Prevention Planning Division Public Work9 Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 12/15/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/12/16 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S .INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 LEGACY TELECOMMUNICATION INC Page 1 of 3 Home Espanol Contact Safety & Health Claims & Insurance 0054 Washington State Department of kj Labor & Industries Search L&I — I ,4 A-Z Index Help R1y L&I Workplace Rights Trades & Licensing LEGACY TELECOMMUNICATIONS INC Owner or tradesperson PO BOX 360 Principals BURLEY, WA 98322 253-858-0214 TRACY, JAMES M KITSAP County TRACY, RYAN J TRACY, SARAH J Doing business as LEGACY TELECOMMUNICATIONS INC WA UBI No. Business type 602 018 360 Corporation Governing persons JAMES M TRACY JAM IE A TRACY; RYAN J TRACY; SARAH J TRACY; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. CConstruction Contractor .o.n.st.r.u..c.t.i.on Cqn—t..rac.t.or Active. Meets current requirements. License specialties GENERAL License no. LEGACTIO05KD Effective — expiration 05/04/2000— 06/01/2017 Bond ................ International Fidelity Ins Co $12,000.00 Bond account no. 0606557 Received by L&I Effective date 03/06/2013 04/20/2013 Expiration date Until Canceled Bond history Insurance Alaska National Insurance Co $1,000,000.00 Policy no. 15HPS31070 Received by L&I Effective date 08/03/2015 08/01 /2015 Expiration date 08/01 /2016 https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602018360&LIC=LEGACTIO05KD&SAW= 5/26/2016 . r SOUTH CENTER PLACE - 16400 SOUTHCENTER PARKWAY Vj TUKWILA, WA 98188 SITE ID: SE04000B RElfii SIONS %eS Sha!I b-i to the SCOpe of worktvkth^ 'Zrr€orLr:-:on C . NSTRUCTION DRAWINGS f ` PROJECT SUMMARY THIS PROJECT INCLUDES THE FOLLOWING SCOPE OF WORK: 1. PROPOSED MODIFICATION OF AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY. MODIFICATIONS TO INCLUDE": " REMOVAL OF (2) EXISTING PANEL ANTENNAS (TMBXX-6516-R2M, GAMMA SECTOR ONLY) ' ADDITION OF (1) NEW PANEL ANTENNAS (DBXNH-6565B-A2M, GAMMA SECTOR ONLY) ADDITION OF (2) NEW PANEL ANTENNAS (HBXX-3319DS-A2M, GAMMA SECTOR ONLY) ADDITION OF (1) FRIG AND (1) FXFC (GAMMA SECTOR ONLY) ADDITION OF (6) DIPLEXERS (ECC1920-VPUB, GAMMA SECTOR ONLY) ADDITION OF (2) FSMF, (2) FBBC, & (1) ESMB IN (E) CABINET ALL OTHER EXISTING EQUIPMENT TO REMAIN, SEE FBdAL EQUIPMENT ]INVENTORY TABLE ON A4.0 FOR COMPLETE SPECIRCAT1ONS. r _------ PROJECT VICINITY & AERIAL MAPS .^r 4f , PROJECT a LOCATION 1 DRIVING DIRECTIONS FROM T-MOBILE BOTHELL OFFICE: 1. TAKE RAMP LEFT FOR 1-405 SOUTH TOWARD RENTON (24.2 MI) 2. TAKE RAMP RIGHT FOR 1-5 NORTH TOWARD SOUTHCENTER BLVD & MALL (0.3 MI) 3. TURN RIGHT ONTO SOUTHCENTER BLVD (0.3 MI) 4. TURN RIGHT ONTO 61 ST AVE S (0.1 MI) 5. TURN RIGHT ONTO SOUTHCENTER PKWY (0.6 MI) 6. ARRIVE AT 16400 SOUTHCENTER PKWY, TUKWILA, WA 98188 ESTIMATED DISTANCE: 26.0 MILES ESTIMATED TIME: 30 MINUTES SITE INFORMATION PROJEdT CONTACTS DRAWING INDE - Wffff SITE NAME: SOUTHCENTER PLACE APPLICANT SHEET DESCRIPTION REVIE SITE ID: SITE ADDRESS: SE04000B 16400 PARKWAY T-MOBILE T1.0 TITLE SHEET CODE COMPLIANCE SOUTHCENTER TUKWILA, WA 98188 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 GN1.0 GENERAL NOTE I�/ 1n(. �O V E0 �r , LATITUDE: 47-27'19.0- N (47.455278) PROPERTY OWNER A1.0 OVERALL SITE P i N LONGITUDE: 122°15'42.0- W (122.261667) LEGACY PARTNERS COMMERCIAL A1.1 ENLARGED RO :PLAN ee� 1 1 2016 SOURCE: I 4000 E THIRD AVE, SUITE 600 A2.0 ENLARGED EQU MENT PJ� PARCEL NUMBER: 2623049021 FOSTER CITY, CA 94404 A3.0 ELEVATIONS ZONING CLASSIFICATION: TUC PROJECT CONSULTANT A4.0 ANTENNA DETAI S 8 PLANS JURISDICTION: TOP OF (E) PENTHOUSE: CITY OF TUKWILA 73.0' AGL CENTERLINE SOLUTIONS 8218 154TH AVE NE A5.0 ANTENNA & EQL PMENT eitrof Tukwila OCCUPANCY GROUP: U REDMOND, WA 98052 RICK STOCKMANN A6.0 CONSTRUCTIONMLDING ��J DIVISION �: S ' b'ef ON TYPE: --- B PH: 425.890.1437 RF1.0 RF DETAILS SITE ACQUISITION CONSULTANT C:Dnr -' the se<30 CENTERLINE SOLUTIONS V -I j `t- 1 111 c `^`� `' 8218 154TH AVE NE 1' ' y L,J ��" t 'I Q� REDMOND, WA 98052 F[+- Jlr .' ✓' I�Ct1. RECEIVED p . ., RICK STOCKMANN chanical CITY OF TUKWILA PH: 425.890.1437 v and rr- , f - CEN ERLINPE PERMITTING SOLUTIONS E ec.S ical DEC 1 1 2015 • 8218 154TH AVE NE 1PIumbing REDMOND, WA 98052 y RICK STOCKMANN a�._. PH:� . 425.890.1437 Gas Piping ERNJIT CENTER k' Q ... CONSTRUCTION MANAGER * , CENTERLINE SOLUTIONS Cttf of f 1 +y� LIxwila 16. F a 8218 154TH AVE NE 1I R OS° Al1I / REDMOND, WA 98052 Intl 1 ! ivi :_+ION NX� RICK YOUNG TN MN r11 PH: 425.954.8613 RF ENGINEER W E $F= T-MOBILE Know what's below. PROJECT z 19807 NORTH CREEK PKWY N Call before you dig. LOCATION GLENN S 98011 ) „ GLENN DIME STRUCTURAL ENGINEER THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY �{ y� !'tYECXF RUCTURAL ENGINEERS L:<YY ATE STREET, SUITE 101 NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO T-MOBILE SANDY, UT 84070 SERVICES IS STRICTLY PROHIBITED. ROGER T. ALWORTH, S.E. 'v tix F P : .990 1775 GOVERNING CODES �� IBC-2012, INTERNATIONAL BUILDING CODE W/ LOCAL Plan review apprnvel is suect to errors and omi'3sions. AMENDMENTS NEC-2008, NATIONAL ELECTRICAL CODE Approval of Consiructiun documents does not aulf lorize A.DJL COMPUANCE the violatinn rt ,ny adopsod coda or Ordinances. Rsecc pt INSTALLATION IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAP ACCESS IS NOT REQUIRED of approLvoi:I 1 iold CopyyAnd Conditiof is is acknowledged: PER A.DA. Y1 ' � i/�il�ifiL IMA 1 Cit`j of T ukwi;a SIGN OFF OF FINAL CONSTRUCTION DRAWINGS REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED CONSULTANT SIGNATURE DATE SITE ACQUISITION PERMITTING CONSULTANT RF ENGINEER: CONST. MNGR. OPS MGR. PROD M GU ORY V. M IV S -low CENTERLINE "t JTIONT Adiw,6v ifS�rrfiaAhtm* *ECTOR n • 1 n ! ! R • It AtttP.- - i 11/12/15 EXP.1/27/16 CPM PROJECT NO.: 8856 PRELIMINARY NO. DATE D/C DESCRIPTION 0 10722715 MS/MS 90%CDREVIEW 1 11-11-15 MS/MS CLIENT COMMENT SUBMITTAL INOI DATE I D/C DESCRIPTION 1 11-11-15 MS/MS BP SUBMITTAL SITE NAME: SOUTHCENTER PLACE SITE ID: SE04000B SITE ADDRESS: 16400 SOUTHCENTER PARKWAY TUKWILA, WA 98188 SHEET TITLE TITLE SHEET SHEET NO. T1.0 GENERALNOTES 1. THE FACILITY IS AN UNOCCUPIED SPECIALIZED MOBILE RADIO FACILITY. 2. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A GRAPHIC REPRESENTATION OF THE FINAL INSTALLATION. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, AND DIMENSIONS AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE PROJECT MANAGER. 4. THE CONTRACTOR SHALL RECEIVE, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK. 5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 6. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY BEARING ON THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL AND STATE JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS. 7. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE PROJECT MANAGER AND WITH LANDLORD'S AUTHORIZED REPRESENTATIVE. 8. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 5 FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA DURING CONSTRUCTION. 9. THE CONTRACTOR SHALL PROVIDE SITE FOREMAN WITH A CELLULAR PHONE, AND KEEP SAME ON SITE WHENEVER ANY PERSONNEL ARE ON SITE. 10. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 11. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, PAVING, CURBS, GALVANIZED SURFACES, ETC., AND UPON COMPLETION OF WORK, REPAIR ANY DAMAGE THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF THE PROJECT MANAGER AND/OR LANDLORD. 12. ON A DAILY BASIS: KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH, AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST OR SMUDGES OF ANY NATURE. 13. CONTRACTOR TO PROVIDE COMPLETE SET OF AS -BUILT DRAWINGS WITHIN 10 WORKING DAYS OF PROJECT COMPLETION. 14 WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED, THE DETAIL SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 15. ASTM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION. 16 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE EXECUTION OF THIS WORK. 17. ALL ITEMS REMOVED OR DAMAGED DURING CONSTRUCTION WORK WILL BE REPLACED OR REPAIRED TO MATCH EXISTING. 18. ALL ELEMENTS OF EXISITNG STRUCTURE TO REMAIN INDISTURBED, LINO. EXISTING STRUCTURE IS ASSUMED TO BE IN GOOD CONDITION, FREE OF DAMAGE OR DETEREORATION. CONTRACTOR TO VERIFY ALL ELEMENTS OF EXISTING STRUCTURE AFFECTED BY THIS MODIFICATION AND NOTIFY FOR IF ANY DAMAGE, DETEREORATION, OR DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THOSE DEPICTED ON THESE CONSTRUCTION DRAWINGS ARE FOUND. SPECIAL INSPECTION 1. IF REQUIRED, SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT SPECIAL INSPECTOR. 2. THE SPECIAL INSPECTOR SHALL PROVIDE A COPY OF THEIR REPORT TO THE OWNER, ARCHITECT, STRUCTURAL ENGINEER, CONTRACTOR, AND BUILDING OFFICIAL AS EACH TEST IS COMPLETED. 3. ANY MATERIAL WHICH FAILS TO MEET THE PROJECT SPECIFICATIONS SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER. SPECIAL INSPECTION TESTING REQUIREMENTS APPLY EQUALLY TO ALL BIDDER DESIGNED COMPONENTS. 4. INSPECTION FOR PREFABRICATED CONSTRUCTION SHALL BE THE SAME AS FOR THE MATERIAL USED IF THE CONSTRUCTION TOOK PLACE ON SITE. CONTINUOUS INSPECTION WILL NOT BE REQUIRED DURING PREFABRICATION IF THE APPROVED AGENCY CERTIFIES THE CONSTRUCTION AND FURNISHES EVIDENCE OF COMPLIANCE. 5. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT CERTIFYING THAT ALL WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF THE SPECIAL INSPECTOR'S KNOWLEDGE IN CONFORMANCE WITH THE APPROVED PERMIT PLANS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS. STRUCTURAL NOTES GENERAL STRUCTURAL NOTES: 1. WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED, THE DETAIL SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 2. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES. 3. NO PIPES, DUCTS, SLEEVES, CHASES, ETC., SHALL BE PLACED IN SLABS, BEAMS, OR WALLS UNLESS SPECIFICALLY SHOWN OR NOTED, NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC., UNLESS OTHERWISE NOTED. CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC. 4. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD T-MOBILE AND THE ARCHITECT/ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF T-MOBILE OR THE ARCHITECT/ENGINEER. 5. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKERS, AND PEDESTRIANS DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, TEMPORARY STRUCTURES, AND PARTIALLY COMPLETED WORK, ETC. OBSERVATION VISITS TO THE SITE BY THE ARCHITECT/ENGINEER SHALL NOT INCLUDE INSPECTION OF SUCH ITEMS. 6. ASTM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION. 7. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOOR OR ROOF. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. PROVIDE ADEQUATE SHORING/BRACING WHERE STRUCTURE HAS NOT ATTAINED DESIGN STRENGTH. 8. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE PROSECUTION OF THIS WORK. 9. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS. 10. THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS. 11. ALL ITEMS REMOVED DURING CONSTRUCTION WORK (I.E., DRYWALL, PLYWOOD, CEILING PANELS, ETC.) SHALL BE REPLACED TO MATCH EXISTING. THE FOLLOWING REQUIREMENTS SHALL BE MET FOR SPECIAL INSPECTION: A. THE SPECIAL INSPECTOR SHALL BE UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER. B. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE ARCHITECT/ENGINEER, AND OTHER DESIGNATED PERSONS. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION; THEN, IF UNCORRECTED, TO THE PROPER DESIGN AUTHORITY AND THE BUILDING OFFICIAL. C. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT SIGNED BY BOTH HE AND HIS SUPERVISOR STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS IN CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE. D. COMPLY WITH ALL CITY SPECIAL INSPECTION REQUIREMENTS. STANDARD STRUCTURAL STEEL NOTES: 1. ALL METAL WORK SHALL BE IN ACCORDANCE WITH THE SPECIFICATION GALVANIZED ASTM A123-A123M-02 UNLESS NOTED OTHERWISE. 2. STRUCTURAL TUBING MEMBERS SHALL CONFORM TO ASTM A500, GRADE A OR A501. 3. ALL WELDING SHALL BE DONE USING E70XX ELECTRODES AND WELDING SHALL CONFORM TO AISC AND AWS D1.1 WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM SIZE PER TABLE J2.4 IN THE AISC'MANUAL OF STEEL CONSTRUCTION-,14TH EDITION. 4. BOLTED CONNECTIONS SHALL USE BEARING TYPE GALV. ASTM A307 BOLTS (5/8- DIA. UNO) AND SHALL HAVE A MINIMUM OF TWO BOLTS U.N.O AND SHALL INCLUDE HEAVY -HEX NUTS AND STANDARD CUT WASHERS. 5. NON-STRUCTURAL CONNECTIONS FOR HANDRAIL, LADDERS AND STEEL GRATING MAY USE 5/8- DIA GALVANIZED ASTM A307 BOLTS U.N.O. 6. ALL STRUCTURAL PIPE ASTM A53, TYPE E OR S, GRADE B. SPECIAL INSPECTION: 1. IF REQUIRED, SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT SPECIAL INSPECTOR PER CODE FOR THE FOLLOWING ITEMS: A. CONTINUOUS DURING THE INSTALLATION OF EXPANSION AND/OR ADHESIVE ANCHORS: INSPECT HOLE SIZE, DEPTH, CLEANLINESS, AND INSTALLATION PER [CC REPORT. B. PERIODIC FOR HIGH STRENGTH BOLT INSTALLATIONS (A325). DRAWING ABBREVIATIONS AFF ABOVE FINISH FLOOR LF LINEAR FEET AGL ABOVE GRADE LEVEL MAX MAXIMUM AWG AMERICAN WIRE GAUGE MECH MECHANICAL AC AIR CONDITIONING MFR MANUFACTURER ADJ ADJUSTABLE MGR MANAGER APPROX APPROXIMATELY MIN MINIMUM AZ AZIMUTH MISC MISCELLANEOUS BLDG BUILDING MTL METAL CM CONSTRUCTION MANAGER MTZL METALIZE(D) CAB CABINET MW MICROWAVE CL CENTERLINE NEC NATIONAL ELECTRICAL CODE CLG CEILING NIC NOT IN CONTRACT CLR CLEAR NTS NOT TO SCALE CO COPPER N/A NOT APPLICABLE CONC CONCRETE OC ON CENTER COND CONDUIT OD OUTSIDE DIAMETER CONST CONSTRUCTION OP OVERHEAD POWER CONT CONTINUOUS OT OVERHEAD FIBER CPM CASCADIA PM OPP OPPOSITE D/C DRAFTERICHECKER PL PROPERTY LINE DEMO DEMOLISH PLYWD PLYWOOD DIA DIAMETER PM PROJECT MANAGER DIM DIMENSION PROJ PROJECT ON DOWN PROP PROPERTY DTL DETAIL PT PRESSURE TREATED DWG DRAWING UGH OPENING EA EACH WED RI HT OF WAY ELECT ELECTRICIL MP OTE RADIO UNIT ELEV ELEVATIO Ej R UIRED EQ EQUAL SBT SO ID BARE TINNED COPPER EQUIP EQUIPMEN JAN I W1 13 SO ARE FEET EXT EXTERIOR SHT SH T FIN FINISH SPEp SPE IFICATION FLR FLOOR CI 0 U RE FT FOOT, FEET ILDIN LESS STEEL GA GAUGE STL STEEL GALV GALVANIZED STRUCT STRUCTURE, STRUCTURAL GC GENERAL CONTRACTOR TOC TOP OF CONCRETE GWB GYPSUM WALL BOARD TOM TOP OF MASONRY GR GRADE THRU THROUGH GRND GROUND TNND TINNED HVAC HEATING, VENTING & AIR CONDITIONING UBC UNIFORM BUILDING CODE HORIZ HORIZONTAL UG UNDERGROUND HT HEIGHT LINO UNLESS NOTED OTHERWISE IBC INTERNATIONAL BUILDING CODE UP UNDERGROUND POWER ID INSIDE DIAMETER RECEIVED UNDERGROUND FIBER IN INCH TY Ot- VERIFY IN FIELD INSUL INSULATION VERT VERTICAL INT INTERIOR DEC 11 24�5 WATERPROOF JBOX JUNCTION BOX W/ WITH LB(S) POUND(S) PERMIT CIEWER I WITHOUT *CENTERLINE SOIJTIONS AO 1dV W*WwAWAvft VECTOR`\/\ t I 11/12/15 EXP.1/27/16 CPM PROJECT NO.: 8856 PRELIMINARY NO DATE 1 D/C DESCRIPTION 0 10-22-15 MS/MS 90%CD REVIEW 1 11-11-15 IMS/MSI CLIENT COMMENT SUBMITTAL 1NO.1 DATE D/C DESCRIPTION 1 111-11-151MS/MSI BP SUBMITTAL SITE NAME: SOUTHCENTER PLACE SITE ID: SE04000B 8ITE ADDRESS: 16400 SOUTHCENTER PARKWAY TUKWILA, WA98188 SHEET TITLE GENERAL NOTES SHEET NO. GN1.0 I t 1 I I t I it I I I I I I I I I i I ' I 1 I I i I I I t l I I j I t G I w I I I I I I W � 1 II I r 1 0 w I I I I i I I I � I I I I i I I i ) , I I I I I I I I 1 li I I I I I I i I I 1 it I I i ! I I I I I I 1 I OVERALL SITE PLAN I I I I I I I I I I IBUILDING (' I I I 1 I I I I 1 STRANDER BLVD 1 1 1 A3.0 1 %711 IPARCEL #: 2623049021 1 I I 1 I I I I 1 1 INGRESS/EGRESS FROM STRANDER BLVD (E) ADJACENT PROPERTY LINE (TYP) (E) SUBJECT PROPERTY LINE (TYP) DRAWING LEGEND - - - - - - SUBJECT PROPERTY LINE - - - - - ADJACENT PROPERTY LINE COAX COAX ROUTE HYBRID HYBRID CABLE ROUTE z x EXISTING FENCE X XX.X ELEVATION MARKER X XX.X DETAIL REFERENCE X XX.X SECTION MARKER COMMON ABBREVIATIONS (E) EXISTING (N) NEW ABBREVIATIONS CONTINUED (TYP) TYPICAL ON SHEETGNI.0 NOTE: SITE PLAN DERIVED FROM; EXISTING DRAWINGS, GIS, AERIAL IMAGES AND SITE PHOTOS. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 11 2016 city of Tukwila BUILDING DIVISION RECEIVED 4*CENTERLINE SOLUTIONS AdkW,d,gNZ 1WA4fimzb *rECTO� II ■ 1 n ■ ■ R ■ CPM PROJECT NO.: 8856 PRELIMINARY NO DATE D/C DESCRIPTION 0 10-22-15 MS/MS 90 % CD REVIEW 1 11-11-15 MS/MS CLIENT COMMENT suBMmAL NO DATE 1 D/C DESCRIPTION 1 11-11-15 MS/MS BP SUBMITTAL SfTE NAME' SOUTHCENTER PLACE SITE 10: SE04000B SITE ADDRESS: 16400 SOUTHCENTER PARKWAY TUKWILA, WA98188 CITY OF TUKWILA SHEET TITLE DEC 1 1 2015 16.05" ENLARGED " ROOF PLAN PERMIT CENTER TN MN W E SHEET NO. SCALE: 1"=40'-0"(11X17) 0' 20' 40' S 80' A1.1 SCALE: 1"= 20'-0" (22X34) (E) T-MOBILE ANTENNAS, TYP OF (2) IN GAMMA SECTOR ONLY, TO BE REMOVED (E) T-MOBILE DIPLEXER (TYP OF 2 PER SECTOR, 6 TOTAL) TO REMAIN (E) PENTHOUSE GAMMASECTOR / . cm 7 7 � i (E) T-MOBILE FXFB (RRU) (TYP OF 1 PER SECTOR, 3 TOTAL) TO REMAIN (E) T-MOBILE TMA (TYP OF 2 PER SECTOR, 6 TOTAL) TO REMAIN (E) ROOFTOP VENT, TYP. ALPHA SECTOR \\ tp ,y0 P O z 5� 0 BETA SECTOR (E) T-MOBILE FRLB MOUNTED BEHIND ANTENNA ON (E) PIPE MOUNT (TYP OF 1 PER SECTOR, 3 TOTAL) SCALE: 1/8" = V-0" (11X17) ENLARGED ROOF PLAN - EXISTING SCALE: 1/4" = V-0" (22X34) (E) T-MOBILE ROOFTOP MOUNTED EQUIPMENT BELOW (E) T-MOBILE FRIG (RRU) (TYP OF 1 PER SECTOR, 3 TOTAL)TO BE RELOCATED (E) PENTHOUSE VENT, TYP. (E) T-MOBILE COVP (TYP OF 1 PER SECTOR, 3 TOTAL) TO REMAIN (E) T-MOBILE PANEL ANTENNAS, TYP OF (4) TO REMAIN 16.05° N TN MN W E S DRAWING LEGEND — — — — — — SUBJECT PROPERTY LINE — — — — — ADJACENT PROPERTY LINE COAX COAX ROUTE HYBRID HYBRID CABLE ROUTE x—--x EXISTING FENCE X XX.X ELEVATION MARKER X XX.X DETAIL REFERENCE X XX.X SECTION MARKER COMMON ABBREVIATIONS (E) EXISTING IN) NEW ABBREVIATIONS CONTINUED (TYP) TYPICAL ON SHEET GN1.0 GAMMA SECTOR ti (N) T-MOBILE PANEL ANTENNAS (TYP OF 2) MOUNTED ON (E) WALL PIPE MOUNTS; SUITABILITY OF MOUNT FOR FINAL LOADING CONFIGURATION TO BE VERIFIED BY OTHERS PRIOR TO INSTALLATION (N) T-MOBILE DIPLEXERS, TYP OF (3),(6 TOTAL), TO BE MOUNTED BEHIND (N) HBXX MODEL ANTENNAS (N) T-MOBILE FXFC, MOUNTED ON (E) PLATFORM W/ (E) FXFB UNIT Q- 0+}rphryry0 P F' BETA SECTOR ENLARGED ROOF PLAN - FINAL (N) T-MOBILE PANEL ANTENNAS (TYP OF 1) MOUNTED ON (N) WALL PIPE MOUNT, SEE 1/A6.0 (N) T-MOBILE FRIG (RRU) MOUNTED BEHIND (N) ANTENNA ON IN) PIPE MOUNT BELOW (E) FRIG (E) T-MOBILE FXFB (RRU) (TYP OF 1 PER SECTOR, 3 TOTAL) TO REMAIN (E) T-MOBILE TMA (TYP OF 2 PER SECTOR, 6 TOTAL) TO REMAIN IN) T-MOBILE DIPLEXERS, TYP OF (3), (6 TOTAL), TO BE MOUNTED BEHIND (N) HBXX MODEL ANTENNAS (E) T-MOBILE COVP (TYP OF 1 PER SECTOR, 3 TOTAL) TO REMAIN VED FOR APPROW ,,; 1 1 20 / (E'T-MOBILE PANEL A TEAIN NASC POv fF�4 TQ.AIla m R t q�y�e BUILDI&% DIVISION RECEIVED CITY OF TUKWILA (E) PENTHOUSE; CAPACITY TO SUPPORT THE PROPOSED LOADING CONFIGURATION TO BE ANALYZED BY OTHERS (E) T-MOBILE FRLB MOUNTED BEHIND ANTENNA ON (E) PIPE MOUNT (TYP OF 1 PER SECTOR, 3 TOTAL) DEC 1 1 2015 PERMIT CEN16.0 R TN MN W E S SCALE: 1/8" = V-0" (11X17) 0' 4' 8' 16' SCALE: 1 /4" = V-0" (22X34) *CENTERLINE SOLUTIONS AaYaadrg l4l04u'A4n-ft �vrEcTOR a n a I n■ a R a CPM PROJECT NO.: 8856 PREUMINARY NO DATE D/C i DESCRIPTION 0 10-22-15 MS/MS 90 % CD REVIEW 1 11-11-15 IMSIMSI CLIENT COMMENT SUBMML NO DATE D/C DESCRIPTION 1 11-11-15 MS/MS BP SUBMITTAL SITE NAME: SOUTHCENTER PLACE SITE ID: SE04000B SITE ADDRESS: 16400 SOUTH CENTER PARKWAY TUKWILA, WA98188 SHEETTRLE OVERALL SITE PLAN SHEET NO. A1.0 (E) T-MOBILE HI -CAP HYBRID FIBER ROUTED W/ (E) COAX (50 LF, 50 LF & 75 LF) HYBRID HYBRID HYBRID ROUTE OF (12) (E) T-MOBILE (7/8') COAX \ (E) T-MOBILE ANTENNAS & / ANCILLARY EQUIPMENT; \ \\� SEE SHEET A4.0 (E) T-MOBILE PURCELL CABINET TO REMAIN (1) (E) RECTIFIER IN (E) PDU (E) T-MOBILE COVP AT EQUIP. (TYP. OF 3) TO REMAIN 16.05- N TN MN W E S 1 I (E) ENLARGED EQUIPMENT PLAN SCALE: /2"=1'-0"(„X,7) 0' ,' 2' 4' I SCALE: 1' =1'-0' (22X34) 2 COAX 7 ROUTE OF (12) � (E) T-MOBILE (7/8") COAX FIT (N) T-MOBILE ANTENNAS & ANCILLARY EQUIPMENT; SEE SHEET A4.0 (N) ENLARGED EQUIPMENT PLAN L I J HYBRID (E) T-MOBILE HI -CAP HYBRID FIBER ROUTED W/ (E) COAX (50 LF, 50 LF & 75 LF) HYBRID HYBRID , — (E) T-MOBILE PURCELL CABINET TO REMAIN — (1) (E) RECTIFIER IN (E) PDU (E) T-MOBILE COVP AT EQUIP. (TYP. OF 3) TO REMAIN WITHIN (E) T-MOBILE CABINET, INSTALL THE FOLLOWING EQUIPMENT: • (2) FSMF FBBC REVIEWED FOR (1) SM • (2) ESMB CODE COMPUANCF. • REPLACE U190 SYSTEM �QPRROV ED '(1)FSMF ' (1) FBBC I BAN 11 2016 City of Tukwila BUILDING DIVISION ECEIVED CITY OF TUKWILA 16.05- DEC 1 1 2L-z5 TN N MN W E PERMIT CENTER S SCALE: 1/2"= V-0" (11X17) 0' 1' 2' 4' SCALE: 1" = V-0" (22X34) T • -Mobile •° CENTERLINE SOLUTIONS A"xsg I*a*W A%ft** >WECTOR ■ n a m e e n e 11/12/15 EXP.1/27/16 CPM PROJECT NO.: 8856 PRELJMINARY NO DATE D/C DESCRIPTION 0 10-22-15 MS/MS 90% CD REVIEW 1 11-11-15 MSIMSI CLIENT COMMENT SUSNIMAL NO. DATE D/C DESCRIPTION 1 11-11-15 MS/MS BPSUBMITTAL SITE NAME: SOUTHCENTER PLACE SITE ID: SE04000B SITE ADDRESS: 16400SOUTHCENTER PARKWAY TUKWILA, WA 98188 SHEET TITLE ENLARGED EQUIPMENT PLAN SHEET W. A2.0 T"E YT-MOBIL &78.8'E ANTENNA RAD CNTR. \ h (E) TOP OF PENTHOUSE 73.0' (E) TOP OF ROOF 62.8' (E) T-MOBILE FRIG (RRU) (TYP OF 1 PER SECTOR, 3 TOTAL) TO REMAIN (E) T-MOBILE COVP (TYP OF 1 PER SECTOR, 3 TOTAL) TO REMAIN (E) T-MOBILE DIPLEXER (TYP OF 2 PER SECTOR, 6 TOTAL) TO REMAIN (E) T-MOBILE TMA (TYP OF 2 PER SECTOR, 6 TOTAL) TO REMAIN (E) T-MOBILE FXFB (RRU) (TYP OF 1 PER SECTOR, 3 TOTAL) TO REMAIN (E) T-MOBILE PANEL ANTENNAS IN GAMMA SECTOR, TOTAL OF (2), TO BE REMOVED (E) T-MOBILE PANEL ANTENNAS IN ALPHA AND BETA SECTOR, TOTAL OF (4), TO REMAIN (E) T-MOBILE FRLB MOUNTED BEHIND ANTENNA ON (E) PIPE MOUNT (TYP OF 1 PER SECTOR, 3 TOTAL) (E) BUILDING SCALE: 1" = 20'-0" (11X17) 0' 10, 20' 40' I 1 EXISTING NE ELEVATION SCALE: 1'=10'-0'(22X34) (N) T-MOBILE PANEL ANTENNAS IN GAMMA SECTOR ONLY (TYP OF 3) MOUNTED ON (E) & (N) WALL PIPE MOUNTS -MOBILE ANTENNA RAD CNTR. \ 7N& 78.5' 73.0' NOP OF ROOF ' (N) T-MOBILE FRIG (RRU) MOUNTED BEHIND (N) ANTENNA ON (N) PIPE MOUNT (E) T-MOBILE BTS EQUIPMENT TO REMAIN (N) T-MOBILE FXFC, MOUNTED ON (E) PLATFORM W/ (E) FXFB UNIT (N) T-MOBILE DIPLEXERS, TYP OF (6),(8 TOTAL), TO BE MOUNTED BEHIND (N) HBXX MODEL ANTENNAS (3 NEW & 1 EXISTING PER ANTENNA) (E) T-MOBILE FRIG (RRU) (TYP OF 1 PER SECTOR, 3 TOTAL) TO REMAIN (E) T-MOBILE COVP (TYP OF 1 PER SECTOR, 3 TOTAL) TO REMAIN (E) T-MOBILE DIPLEXER (TYP OF 2 PER SECTOR, 6 TOTAL) TO REMAIN (E) T-MOBILE TMA (TYP OF 2 PER SECTOR, 6 TOTAL) TO REMAIN 2 1 FINAL NE ELEVATION NOTES: E T-MOBILE ANTENNA TIP HEIGHT 81.33 IF REQUIRED, PAINT TO MATCH ANTENNAS AND ANCILLARY EQUIPMENT TO MATCH E T-MOBILE ANTENNA RAD CNTR. THE EXISTING STRUCTURE WITH NON -REFLECTIVE PAINT AS REQ'D. CONTRACTOR 78 3' & 78 8' TO VERIFY COLOR AND FINISH WITH LANDLORD AND/OR JURISDICTION. PRIOR TO MATERIALS PROCUREMENT CONTRACTOR SHALL FIELD VERIFY CONDITION OF STRUCTURE AT PROPOSED MOUNTING LOCATION TO ENSURE (E) T-MOBILE PANEL ANTENNAS IN ALPHA AND EXISTING CONDITIONS ARE SUITABLE AT SPECIFIED ELEVATION. BETA SECTOR, TOTAL OF (4). TO REMAIN • NEW ANTENNAS SHALL NOT EXCEED EXISTING TIP HEIGHT U.N.O. • RETURN ALL USED EQUIPMENT AND HARDWARE TO T-MOBILE WAREHOUSE. ALL CLIMBING PATHS ON TOWER/MON OLE fQtgo-M fit F MOUNTS, EQUIPMENT, ETC. (E) T-MOBILE FRLB MOUNTED BEHIND _ ANTENNA ON (E) PIPE MOUNT (TYP OF 1� PER SECTOR, 3 TOTAL) i � (E) T-MOBILE FXFB (RRU)� (TYP OF 1 PER SECTOR, 3 TOTAL) TO REMAIN APPROVED JAN 11 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 1 1 2015 PERMIT CENTER SCALE: 1' = 20'-0" (11 X17) 010, 20' 40 SCALE: 1" =10'-0" (22X34) ■ ■ -Mobile •v *CENTERLINE SOLUTIONS AdwjdV 11117nfMAWWOOS >veCTOR a n a i n a■ R a i 11/12/15 EXP.1/27/16 CPM PROJECT NO.: 8856 PREL11IIINARY NO DATE D/C DESCRIPTION 0 10-22-15 MS/MS 90% CD REVIEW 1 11-11-15 IMS/MSI CLIENT COMMENT SUBMTTAL NO. DATE D/C DESCRIPTION 1 ,1-11-15 MS/MS BPSUBMITTAL SITE NAME: SOUTHCENTER PLACE --_ SITE ID: SE04000B STTE ADDRESS- 16400 SOUTHCENTER PARKWAY TUKWILA, WA98188 SHEET TITLE ELEVATIONS SHEET NO. A3.0 ANTENNA SCHEDULE - FINAL CONFIGURATION SECTOR POS. EXIST. / NEW MNFR. ANTENNA MODEL PORT DIMENSIONS (L x W x D) WEIGHT (LBS) Al EXISTING ANDREW TMBXX-6516-R2M QUAD 59.0" x 11.9" x 6.3" 34.6 ALPHA A2 EXISTING COMMSCOPE SBNHH-1 D65B HEX 72.6" x 11.9" x 7.1" 40.6 B1 EXISTING ANDREW TMBXX-6516-R2M QUAD 59.0" x 11.9" x 6.3" 34.6 BETA B2 EXISTING COMMSCOPE SBNHH-1 D65B HEX 72.6" x 11.9" x 7.1" 40.6 C1 NEW COMMSCOPE HBXX-3319DS-A2M QUAD 57.0" x 22.2" x 4.9" 38.1 GAMMA C2 NEW COMMSCOPE DBXNH-6565B-A2M QUAD 72.7" x 11.9" x 7.1" 46.3 DELTA D3 NEW COMMSCOPE HBXX-3319DS-A2M QUAD 57.0" x 22.2" x 4.9" 38.1 *TOWER - FINAL EQUIPMENT INVENTORY SCOPE QTY. TECHNOLOGY MNFR. MODEL DIMENSIONS (L X W X D) WEIGHT (LBS) (E) TO REMAIN (2) ANTENNA ANDREW TMBXX-6516-R2M 59.0" x 11.9" x 6.3' 34.6 REMOVE (E) (1) ANTENNA ANDREW TMBXX-6516-R2M 59.0" x 11.9" x 6.3" (34.6) (E) TO REMAIN (2) ANTENNA COMMSCOPE SBNHH-1 D65B 72.6" x 11.9" x 7.1" 40.6 REMOVE (E) (1) ANTENNA COMMSCOPE SBNHH-1D65B 72.6" x 11.9" x 7.1" (40.6) ADD (N) (1) ANTENNA COMMSCOPE DBXNH-6565B-A2M 72.7" x 11.9" x 7.1" 46.3 ADD (N) (2) ANTENNA COMMSCOPE HBXX-3319DS-A2M 57.0" x 22.2" x 4.9" 38.1 (E) TO REMAIN (3) RRU NOKIA FXFB 19.3" x 22.0" x 5.2" 55.0 (E) TO REMAIN (3) RRU NOKIA FRIG 23.8" x 17.2" x 7.5" 59.9 ADD (N) (1) RRU NOKIA FRIG 23.8" x 17.2" x 7.5" 59.9 ADD (N) (1) RRU NOKIA FXFC 19.3" x 22.0" x 5.2" 55.0 (E) TO REMAIN (3) COVP RAYCAP CR100-1076R06 20.2" x 19.0" x 7.0" 15.0 (E) TO REMAIN (6) TMA ANDREW ETT19V2S12UB (DUAL AWS/PCS) 9,4" x 7.3" x 3.5" 13.9 (E) TO REMAIN (6) DIPLEXER COMMSCOPE ECC1920-VPUB 7.6" x 7.3" x 2.6" 7.9 ADD (N) (6) DIPLEXER COMMSCOPE ECC1920-VPUB 7.6" x 7.3' x 2.6" 7.9 *GROUND - FINAL EQUIPMENT INVENTORY DIMENSIONS WEIGHT SCOPE QTY. TECHNOLOGY MNFR. MODEL (L X W X D) (LBS) (E) TO REMAIN (3) COVP RAYCAP RNSNDC-7771-PF-48 18.85" x 16.08" x 5.83" 19.0 THE "TOWER" AND "GROUND" REFERENCES REFER TO NOMENCLATURE REFLECTED IN THE PLUMBING DIAGRAM ON THE RF1.0 SHEET AND DO NOT NECESSARILY REFER TO ACTUAL LOCATION OF EQUIPMENT. GROUND EQUIPMENT NOTE: • NEW FBBC TO BE INSTALLED IN EXISTING FCOA CABINET (QUANTITIES MAY VARY). ALL OTHER BASEBAND MODULES ARE ASSUMED TO BE EXISTING. ANTENNA NOTES: • REFERENCE OWNERS MANUAL FOR CONNECTION AND MOUNTING INFORMATION FOR AMPLIFIER IF REQUIRED. • CONTRACTOR SHALL VERIFY FINAL ANTENNA AZIMUTHS W/ CLIENT REPRESENTATIVE PRIOR TO COMMENCING INSTALLATION. • PRIOR TO MATERIALS PROCUREMENT CONTRACTOR SHALL FIELD VERIFY SUITABILITY OF ANTENNA MOUNT AT SPECIFIED ELEVATION. • IF REQUIRED, PAINT TO MATCH ANTENNAS AND ANCILLARY EQUIPMENT TO MATCH THE EXISTING STRUCTURE WITH NON -REFLECTIVE PAINT AS REQ'D. CONTRACTOR TO VERIFY COLOR AND FINISH WITH LANDLORD AND/OR JURISDICTION. • RETURN ALL UNUSED EQUIPMENT TO T-MOBILE WAREHOUSE. ANTENNA AND ANCILLARY EQUIPMENT GAMMA SECTOR Y� a Y y Q (E) T-MOBILE FRIG (RRU) (TYP OF 1 �? PER SECTOR, 3 TOTAL) TO BE " RELOCATED o, �7 (E) T-MOBILE ANTENNAS, TYP OF (2) IN GAMMA SECTOR ONLY, TO BE REMOVED i (E) T-MOBILE DIPLEXER (TYP OF 2 PER (E) T-MOBILE FXFB (RRU) (TYP OF 1 SECTOR, 6 TOTAL) TO REMAIN PER SECTOR, 3 TOTAL) TO REMAIN BETA SECTOR 2 1 EXISTING ANTENNA PLAN GAMMA SECTOR by (N) T-MOBILE PANEL ANTENNAS (TYP OF 2) MOUNTED ON (E) WALL PIPE MOUNTS; SUITABILITY OF MOUNT FOR FINAL LOADING \\\\ CONFIGURATION TO BE VERIFIED BY OTHERS PRIOR TO INSTALLATION (N) T-MOBILE DIPLEXERS, TYP OF (3),(6 TOTAL), TO BE MOUNTED BEHIND (N) HBXX MODEL ANTENNAS (N) T-MOBILE FXFC, MOUNTED ON (E) PLATFORM W/ (E) FXFB UNIT BETA SECTOR SCALE: NTS (11X17) 3 ( FINAL ANTENNA PLAN SCALE: NTS (22X34) (E) T-MOBILE TMA (TYP OF 2 PER SECTOR, 6 TOTAL) TO REMAIN (E) PENTHOUSE; CAPACITY TO SUPPORT THE PROPOSED LOADING CONFIGURATION TO BE ANALYZED BY OTHERS (E) T-MOBILE FRLB MOUNTED BEHIND ANTENNA ON (E) PIPE MOUNT (TYP OF 1 PER SECTOR, 3 TOTAL) (E) T-MOBILE PANEL ANTENNAS, TYP OF (4) TO REMAIN (N) T-MOBILE PANEL ANTENNAS (TYP OF 1) Q y MOUNTED ON (N) WALL PIPE MOUNT, SEE 1/A6.0 (N) T-MOBILE FRIG (RRU) MOUNTED BEHIND (N) ANTENNA y xy ON (N) PIPE MOUNT BELOW (E) RELOCATED FRIG �y (E) T-MOBILE FXFB (RRU) (TYP OF 1 PER SECTOR, 3 TOTAL) TO REMAIN (E) T-MOBILE TMA (TYP OF 2 PER SECTOR, 6 TOTAL) TO REMAIN (E) PENTHOUSE; CAPACITY TO SUPPORT THE PROPOSED LOADING CONFIGURATION TO BE ANALYZED BY OTHERS (E) T-MOBILE FRLB MOUNTED BEHIND ANTENNA ON (E) PIPE MOUNT (TYP OF 1 PER SECTOR, 3 TOTAL) (E) T-MOBILE PAI ANTENNAS, TYP REMAIN (E) T-MOBILE COVP (TYP OF 1 PER SECTOR, 3 TOTAL) TO REMAIN ALPHA SECTOR 16.05" N TN MN W E S SCALE: NTS (11X17) SCALE: NTS (22X34) RECEIVED CITY OF TUKWILA DEC 1 12015 PERMIT CENTER T-MOBILE COVP (TYP 1 PER SECTOR, 3 ;ODE COMPLIANCE �Atie,�PPR0VED �1y1 0 el 1 2016 City of Tukwila WILDING DIVISI TN MN ALPHA SECTOR W E S SCALE: NTS (11 X1 7) SCALE: NTS (22X34) T 0 -Mobile-, CENTERLINE 50l UTION5 Ad W,dV "*I-AYtaS T WrECTOR ■ n• I n e e R• 4 - 11/12/15 EXP.1/27/16 CPM PROJECT NO.: 8856 PRELIMINARY NO DATE D/C DESCRIPTION 0 10-22-15 MS/MS 90%CD REVIEW 1 11-11-15 IMS/MSI CLIENT COMMENT SUBMITTAL NO DATE D/C DESCRIPTION 1 11-11-15 MS/MS BP SUBMITTAL 8(TE NAME: SOUTHCENTER PLACE SITE ID: SE04000B SITE ADDRESS: 16400 SOUTHCENTER PARKWAY TUKWILA, WA 98188 SHEET TITLE ANTENNA DETAILS & PLANS SHEET NO. A4.0 ANTENNA DATA MECHANICAL SPECIFICATIONS MANUFACTURER HEIGHT WIDTH DEPTH WEIGHT COMMSCOPE 72.7 IN 11.9 IN 7.1 IN 46.3 LBS PART # CONNECTORS STANDARD MOUNTING HARDWARE DBXNH-6565E-A2M (4) 7-16 DIN FEMALE INCLUDED TOP ® TOP ® TOP _ ■ ■ '� -Mobile-* "WIDTH "WIDTH EPT EPTH nWIDTH CENTERLINE DEPTH SOLVTION4 Mhaafig N?r�lmA4Mar#s i i 3 *rECTO� H 2 F FRONT SIDE x x w FRONT 0 SIDE FRONT 0 SIDE 2 w w 2 x NSN FRLB LTE 7�! BAND 14 (REMOTE RADIO UNm HEIGHT: 15.75" WIDTH: 15.75" DEPTH 5.9' WEIGHT: 59.52 LBS t SCALE: NTS (11X17) SCALE: NTS (11X17) SCALE: NTS (11X17) 1 ANTENNA DETAIL 2 ANTENNA DETAIL 3 FRIG (RRU) DETAIL' SCALE: NTS (22X34) SCALE: NTS (22X34) SCALE: NTS (22X34) 11/12/15 EXP.1/27/16 CPM PROJECT NO.: 8856 TOP -- PRELIMINARY NO DATE D/C DESCRIPTION 0 10-22-15 MS/MS 90%CD REVIEW 1 11-11-15 MS/MS CLIENT COMMENT TOP WIDTH SUBMITTAL Q EVIEYYCD FOR NO DATE D/C DESCRIPTION EPTH CODE COMPLIANCE 1 11-11-15 MS/MS BP SUBMITTAL WIDTH PEP APPROVED SITE NAME: JAN 1 1 2016 SOUTHCENTER = 31DE PLACE FRONT c� FRONT w SIDE SITE ID: x City of Tukwila SE04000B BUILDING DIVISION SITEADDRES& 16400 SOUTHCENTER PARKWAY RECEIVEQ TUKWILA, WA98186 CITY OF TUKWILA 3HEETTITLE ECC1Y2aVPUB MU`IIj 70cR1 DEC 1 201 ANTENNA AND NOIw FXFc (REMOTE RADIO uNm EQUIPMENT HEIGHT: 7.6" DETAILS HEIGHT: 19.3' WIDTH: 7.3" PERMIT CENTER WIDTH: 22.0" DEPTH 2.6' DEPTH 5.2" WEIGHT: 7.9 LBS WEIGHT: 55.0 LBS SHEET NO, SCALE: NTS (11X17) SCALE: NTS (11X17) SCALE: NTS (11X17) A5.0 4 FXFC (RRU) DETAIL SCALE: NTS (22X34) 6 DIPLEXER DETAIL SCALE: NTS (22X34) 7 NOT USED scALE:NTs(22X3a) ANTENNA DATA MECHANICAL SPECIFICATIONS MANUFACTURER HEIGHT WIDTH DEPTH WEIGHT COMMSCOPE 57.0 IN 22.2 IN 4.91N 38.1 LBS PART# CONNECTORS STANDARD MOUNTING HARDWARE HBXX-3319DS-A2M (4) 7-16 DIN FEMALE INCLUDED NOTES: - SUITABILITY OF PLATFORM / MOUNT(S) FOR FINAL LOADING CONFIGURATION TO BE VERIFIED BY OTHERS PRIOR TO INSTALLATION. NO WORK SHALL COMMENCE WITHOUT THE APPROVED STRUCTURAL TOWER / ANTENNA / MOUNT ANALYSIS REPORT (SIGNED AND SEALED) TO BE PROVIDED UNDER SEPARATE COVER. CONTRACTOR PRIOR TO CONSTRUCTION SHALL REVIEW THE APPROVED TOWER / ANTENNA / MOUNT ANALYSIS REPORT SUPPLIED BY T-MOBILE AND MODIFY, IF REQUIRED, ALL APPLICABLE MEMBERS AS INDICATED IN CERTIFIED STRUCTURAL REPORT PRIOR TO INSTALLATION ON STRUCTURE. (N) T-MOBILE FRIG MOUNTED BEHIND ANTENNA ON (E) PIPE MOUNT (TYP OF 1 PER SECTOR, 3 TOTAL) (N) T-MOBILE PANEL ANTENNA (TYP OF 1) MOUNTED ON (N) WALL PIPE MOUNTS (N) T-MOBILE DIPLEXER (TYP OF 3) TO BE MOUNTED BEHIND (N) ANTENNA (N) 3" STD. MIN. ANTENNA PIPE (2) (N) VALMONT PART #WWM01 OR APPROVED EQUAL STANDOFF BRACKETS OR (E) MICROWAVE TOWER SERVICE PART #M222 ADJUSTABLE WALL MOUNTS WITH (4) 1/2" ALL -THREAD RODS W/ 4" MIN. EMBED., W/ SIMPSON "EPDXY -TIE" GROUT, TYP. TOP AND BOTTOM (E) MIN. 10" THICK CONCRETE WALL (VERIFY) ANTENNA MOUNTING DETAIL 2 1 NOT USED SCALE: NTS (11 X1 7) 3 I NOT USED SCALE: NTS (22X34) SCALE: NTS (11X17) SCALE: NTS (22X34) REVIEWED FOR CODE COMPLIANCE APPROVED JAN 11 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC I I ?' jj PERMIT CENTER SCALE: NTS (11X17) SCALE: NTS (22X34) rn CENTERLINE AO�/rtUTONS, ,VECTOR e n a in a e w e CPM PROJECT NO.: 8856 PRELIMINARY NO DATE D/C DESCRIPTION 0 10-22-15 MS/MS 90% CD REVIEW 1 11-11-15 MS/MS CLIENT COMMENT SUBMITTAL NO. DATE D/C DESCRIPTION 1 11-115 M -1S/MS BP SUBMITTAL SOUTHCENTER PLACE SITE ID: SE04000B SITE ADDRESS: 16400 SOUTHCENTER PARKWAY TUKWILA, WA98188 SHEET TITLE CONSTRUCTION DETAILS SHEET NO. A6.0 RFDS V. 7 - SECTOR SPLIT Alpha & Beta (Only Alpha Is shcwn) NSN Configuration 705J (N_T05JRUSh_4split_012) umo voi sWlt — 2015 4-Secto- Sins Kith +toot lop Hi7u ::om 9mu= pus Spool n ' Mar :ats 91,110 9.181 Split to Support LTESpxtntm• IS MHZ ' 1 Fad. Modae�te pm - W•wn ,. wu �aadn a' .a Du:t �o at.«. :n A145 a-nn rnta N. -O k. Ye �' 1 1 RF DETAILS - ANTENNA & ANCILLARY EQUIPMENT PLUMBING DIAGRAM NOTES: 1. ALL COAXIAL CABLE CONNECTIONS TO BE WEATHERPROOFED. 2. CONTRACTOR TO DIP CABLES AND JUMPERS WHERE NECESSARY. 3. TAGGING: ' ALL COAXIAL CABLES TO BE MARKED WITH COLOR CODED TAPE TO INDICATE THE ANTENNA SECTOR. COLORED ELECTRICAL TAPE SHALL MARK EACH END OF CABLE AND EACH END OF JUMPERS AS CLOSE TO EACH END AS POSSIBLE. (NOT TO INTERFERE WITH WATERPROOFING.) 4. COAXIAL CABLE SPECIFICATIONS REQUIRE CABLE SUPPORT EVERY T-0" ON CENTER. CONTRACTOR SHALL SUPPLY SUPPORTS AS REQUIRED TO MEET THIS REQUIREMENT. 5. VERTICAL CONNECTIONS SHALL BE TAPED FROM THE BOTTOM UP SO OVERLAP MOVES WATER AWAY FROM CONNECTION (SEE STEP 4). 6. PROVIDE HEAT SHRINK IN PLACE OF TAPE FOR QUAD POLES & TMAS. 7. ALL ANTENNAS & COAXIAL ANTENNA CABLE TO BE FURNISHED BY T-MOBILE AND INSTALLED BY CONTRACTOR. 8. COAX SHALL BE TAGGED WITH COLOR CODING AT (2) PLACES USING 1" WIDE WEATHERPROOF COLORED VINYL TAPE AT THE FOLLOWING LOCATIONS: #1 -AT ANTENNA CONNECTION #2 - AT ENTRY TO EQUIPMENT CABINET 9. RUN COAXIAL CABLE WITH MINIMUM 12" SLACK & 12" FROM EDGE OF EQUIPMENT CABINETS, ACROSS WAVE GUIDE BRIDGE (IF APPLICABLE), UP TO TOWER LEG (IF APPLICABLE), AND DISTRIBUTE TO EACH ANTENNA DEVICE. FURNISH AND INSTALL A MINIMUM OF (3) GROUND KITS PER COAXIAL CABLE. VERIFY NUMBER OF ANTENNAS, CABLE, AND CABLE DIAMETER WITH T-MOBILE CONSTRUCTION MANAGER. REVIEWED FORS CODE COMPLIANCE APPROVED JAN 11 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 1 1 2015 PERMIT CENTER Oje u -Mobile-, CENTERLINE SOLJTtONS AaWoa6p WYedetsA6lwcvAs LVEC Y ®R It n• t n a N R e _ 1 '4112SL 11/12/15 EXP.1/27/16 CPM PROJECT NO.: 8856 PRELIMINARY NO DATE 1 D/C I DESCRIPTION 0 10-22-15 MS/MS 90% CD REVIEW 1 11-11-15 IMS/MSI CLIENT COMMENT SUBMITTAL NOT DATE D/C DESCRIPTION 1 11-11-15 MS /MS BP SUBMITTAL SITE NAME: SOUTHCENTER PLACE SITE ID: SE04000B SITE ADDRESS: 16400 SOUTHCENTER PARKWAY TUKWILA, WA98188 SHEET TITLE RF DETAILS SHEET NO. RF1.0