Loading...
HomeMy WebLinkAboutPermit D15-0316 - SEATTLE INTEGRATIVE CANCER CENTER - OFFICES AND STORAGE CLOSETSEATTLE INTEGRATIVE CANCER CENTER 200 ANDOVER PARK E 3 EXPIRED 01119117 D15-0316 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 0223100099 Permit Number: D15-0316 Address: 200 ANDOVER PARK E 3 Issue Date: j�V /29 2 �1 16 Permit Expires On: Project Name: SEATTLE INTEGRATIVE CANCER CENTER Owner: Name: ANDOVER PLAZA LLC Address: 1501 N 200TH ST, SHORELINE, WA, 98133 Contact Person: Name: LUCIA CHEN Address: 200 ANDOVER PARK E , TUKWILA, WA, 98188 Contractor: Name: WE HONEY DO.COM LLC Address: 10035 MAIN ST REAR OFFICE, BOTHELL, WA, 98011 License No: WEHONHD895C3 Lender: Name: LEXON INSURANCE COMPANY Address: BOND #9808771 $12k , LOUISVILLE, KY, DESCRIPTION OF WORK: Phone: (253) 205-6576 Phone: (425) 775-6123 Expiration Date: 3/17/2017 ADD 3 OFFICE SPACES AND ONE STORAGE CLOSET IN EXISTING STRUCTURE. CONSTRUCT NON BEARING PARTITION WALLS Project Valuation: $27,105.00 Fees Collected: $1,103.22 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No n Permit Center Authorized Signature: /f W�w �I r Date: 4� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development pe m' a d agree to the conditions attached to this permit. Signature:Dat P' (p Print Name: —U—al This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 4: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 3: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 17: Maintain fire extinguisher coverage throughout. 6: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 5: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 10: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 8: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 7: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 12: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 11: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 13: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 14: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 9: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 18: ***BUILDING PERMIT CONDITIONS*** 19: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 20: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 21: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 22: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 23: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 24: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 25: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 26: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 27: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 28: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 29: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 30: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 1400 FIRE FINAL 0409 FRAMING 0406 SUSPENDED CEILING CITY OF TUKr. . A Building Pek tit No. Community Development Department ' Public Works Department Project No. • Permit Center Date Application Accepted: 6300 Southcenter Blvd., Suite 100 ` Tukwila, WA 98188 Date Application Expires: hgpJ/www.TukwilaWA.gov (For office use SITE LOCATION CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" King Co Assessor's Tax No.:: Site Address: ZCV ANPa✓1 r ' ' t� Suite Number: JFloor: Tenant Name: �1 CAIJ %e C '�V� New Tenant: [I ..... Yes 0,3 PROPERTY OWNER Name: y ` Address: u i rLc�o ' C State: ,A.' Zip: CONTACT PERSON — person receiving all project communication Name: Address: �J�7pJeL City: �" V K� `-� State V) A• Zip: SE Phone:2� �(,�b''ax: r. __•r �aokoo• ao . GENERAL CONTRACTOR INFORMATION Company Name: Address: /06,00 City: eF-11rrl'eal- State: \\J Ac Zip• 5o It Phone 2s�J' 1� (�I Fax: W Contr Reg No.: & ate: 3 Tukwila Business License No.: le)G J -2- REI ARCHITECT OF RECORD Company Name: ,\ Architect Name: o WAA to Address: g V� 6 City: F.LZip Phone• ;7 _87l I Fax: P Email: Ana y ENGINEER OF RECORD Company Name: ^&C. Engineer Name: -e vs — Address: d0 b City-,t,0M ,1' State: Zip: p0 0 Phone: O. ax: Email: LV� (;'A LENDER/BOND ISSUED (required f greater per RCW 19.27.095) r projects $5,000 or Name: zff19 7/' , ✓ Cd� t Y Address: d fLZK City: l L State: : H:4Applications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Page 1 of 4 Revised: February 2012 0 BUILDING PERMIT INFORMATIt - 206-431-3670 Valuation of Project (contractor's bid price): $ 2:a t 0 ®� Describe the scope of work (please provide detailed information): A1217 --5 O r�r-1 �-FC7 AAP Existing Building Valuation: God-t'p-v<jr- Will there be new rack storage? ❑ ....Yes Et..No If yes, a separate permit and plan submittal will be required. I Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Constructio] IBC per Type of Occupancy per IBC 1st Floor 32- 2 Floor Yd Floor Floors thru ,_-- Basement Accessory Structure* Attached Garage --^� Detached Garage Attached Carport Detached Carport .......... Covered Deck — --, Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq f3): Floor area of principal dwelling: Floor area of accessoi y dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residej ice. Number of Parking Stalls Provided: Standard: Compact: Handica Will there be a change in use? ❑ ....... Yes ❑ ....... No If "yes", explain: FIRE PROTECTIONIHAZARDOUS MATERIALS: ❑ ....... Sprinklers ❑ .......Automatic Fire Alarm [I ....... None ❑....... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .......Yes ❑ ...... No If `yes', attach list of materials and storage locations on a separate 8-112" x I " paper including quantities and Mater al Safety Data Sheets. S SEPTIC SYSTEM ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by Ki g County Health Department. H:\Applications\Forms-Applications On Line12012 ApplicationsTennit Application Revised - 2-7-12.docx Revised: February 2012 Page 2 Of 4 I. PUBLIC WORKS PERMIT INFO .vIATION — 206-433-0179 Scope of Work (please provide detailed Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ... Water District # 125 ❑... Highline El ... Renton ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ ...Valley View ❑... Renton ❑... Seattle ❑ .. Sewer Use Certificate ❑ ...Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King Count) Submitted with Application (mark boxes which am ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑... Geotechnical Report ❑ .. Traffic Im] ❑ .. Bond ❑... Insurance ❑... Easement(s) ❑... Maintenance Agreement(s) ❑ .. Hold Ham ❑ .. Hold Ham Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑... Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑... Right-of-way Use — Potential Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ .. Total Cut cubic yards ❑ .. Total Fill cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑... Work in Flood Zone ❑... Storm Drainage ❑... Abandon Septic Tank ❑... Curb Cut ❑... Pavement Cut ❑... Looped Fire Line El ... Grease Interceptor ❑... Channelization ❑... Trench Excavation ❑... Utility Undergroun Department. Analysis — (SAO) — (ROW) ❑ .. Permanent Water Meter Size (1) WO # (2) WO # (3) WO # ❑ .. Temporary Water Meter Size (1) WO # (2) WO # (3) WO # ❑ .. Water Only Meter Size ........... WO # ❑ .. Deduct Water Meter Size " ❑ .. Sewer Main Extension ............ Public ❑ Private ❑ ❑ .. Water Main Extension ............ Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billina: Name: Day Telephone: Mailing Address: City State zip H:Wpplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page 3 of 4 PUtKrIr APPU, TION NOTRS — Yabu of — b all ems. a Was of con aucuoa atna = sbculd be catered by the applicaL This figure will bi reviewed and is subjM lb po nwe Imevidan the Pentair Cents to comply with cuncut foe sckdulciL B of PIau — Appliaatioas fur which no past is issued adthia 180 days Mewing the date of applicexpire by t oo. The Ofdal may gtsatone or mac aftwim oftiax: for additional periods not cueediag 90 dapThe ameosion shall be requested writing and jtatiSaMe Cause d raw& Section 10532 IrtandimW Code (biwa 15 • 1 HEREBY TWV THAT 1 HAVE READ AND EXARIMM TMS APPLICATION AND KNOW THE SATRUB UNDER PENALTY OF Y BY 111E LAWS OF TM STATE OF WASH@1GTON, AND i AM AUTROROM TOOR THIS PERMIT. S Pape 4 OU DESCRIPTIONS PermitTRAK QUANTITY PAID $683.12 D15-0316 Address: 200 ANDOVER PARK E 3 Apn: 0223100099 $683.12 DEVELOPMENT $650.80 PERMIT FEE R000.322.100.00.00 0.00 $646.30 WASHINGTON STATE SURCHARGE 13640.237.114 0.00 $4.50 TECHNOLOGY FEE $32.32 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R7445 R000.322.900.04.00 0.00 $32.32 $683.12 Date Paid: Thursday, January 21, 2016 Paid By: WE HONEY DO.COM Pay Method: CREDIT CARD H09910 Printed: Thursday, January 21, 2016 12:15 PM 1 of 1 - SYSTEMS Date Paid: Tuesday, December 29, 2015 Paid By: WEHONEYDO.COM Pay Method: CREDIT CARD H05714 Printed: Tuesday, December 29, 2015 2:36 PM 1 of 1 R SY57EM5 . City of Tukwila Jinn Haggerton, Mayor • Department of Community Development Jack Pace, Director February 22, 2017 Lucia Chen 200 Andover Park E 3 Tukwila, WA 98188 RE: Request for Extension/Reopen — D15-0316 Seattle Integrative Cancer Center Dear Ms. Chen, This letter is in response to your written request to extend permit D15-0316. The Building Official has reviewed your letter and determined that the City of Tukwila Building Division will not be extending the permit.. A notice was mailed to the designated contact for this permit a full month and a half ahead of expiration (letter was dated and mailed December 1, 2016) which provided two options to keep the permit in good standing. The first was to start construction and have an inspection and the second option was to submit a request for extension at least (7) days in advance of the expiration date. The request we did receive was received a month after the actual expiration of the permit. This is why your request for extension has been denied. In order for work to continue and inspections be conducted, a new permit will need to be issued. To do this, complete and submit a new application form along with four (4) sets of plans. As with the original issuance of the permit, this submittal will need to be made in person. Please note this new permit will not be issued over the counter, it will need to go through the complete plan review process If you should have any questions, please contact our office at (206) 433-7165. Sincerely, .1,.� Rachelle Ripley Permit Technician File: Permit No. D15-0316 W-Ternut CenterAExtension Letters\Denials\Permits\20151D15-0113 Extension Denial.dou 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 9 Phone 206-431-3670 • Fax 206-431-3665 Feb.20.2017 10:42AM 31ghtline Health No.8387 P. 2 tidy,• THR: Request for Extension # February 11, 2017 Current Expiration Date: I �� Extension Request: City of Tukwila ❑ Approved for days Code Enforcement ® Denied �rovide explanation) 6300 Southcenter Blvd. �Gf�dr�s Tukwila, WA 98188 z 60 F 00pe f 144� A Signature/Initials Re: File #CE15-0374 f Before the Hearing Officer of the City of Tukwila To whom It may concern, i I am requesting an appeal for falling to meet the deadline regarding the completion of offices. My Practice Manager was out of the clinic due to illness as we approached the deadline and unfortunately it was overlooked. As a solo Oncologist, I have recently encountered financial hardship due to insurance companies failing to pay for chemotherapy treatments, which has negatively affected the business cash flow. Unfortunately, we have not been able to proceed with completion of the offices. It Is my desire In the very near future to complete this permit as we need the space. I respectfully request leniency with our failure to comply and request an extension to the permit as well as an abatement of fines. RECEIVED CITY OF TUKWILA FEB 2 1 2017 PERMIT CENTER SOUTH SOUND ONCOLOGY SERVICES, P.C. DBA Seattle Integrathre Cancer Center 200 Andover park E Suite 3, Tukwila WA 98188 P: 206.588.1722 f: 206.242.2275 www.seattleintegranvecancercenter.com Feb- 20. 2017 10.42AM lights ine Health FAX No.8387 P. 1 X Seattre Integrative Cancer Center To: Ltt4From: Fax: aZa Phone: -X(a - Pa es: r �j Y, Re: CC: Urgent For review Please Comrnent F] Please Reply[] please Recycle -------------- Comments: Dr. Nick Chen & Dr. Mark Gignac Seattle lntergrative Cancer Cdnter 200 Andover Park East Suite 3 Seattle, Washington 98188 P: 206-588-1722 F: 206-2�42-2275 R ECtIVE FEB 212017 Community Development City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 12/1/2016 LUCIA CHEN 200 ANDOVER PARK E TUKWILA, WA 98188 RE: Permit No. D15-0316 SEATTLE INTEGRATIVE CANCER CENTER 200 ANDOVER PARK E Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/19/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/19/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, WVim/ y chelliple Permit Technician File No: D15-0316 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 9 Phone 206-431-3670 9 Fax 206-431-3665 City of Tukwila Jim Haggerton, Mayor • Department of Community Development Jack Pace, Director August 9, 2016 Deb Ellifritt 202 Andover Park E, Ste 3 Tukwila, WA 98188 RE: Request for Extension #1 Permit Number D15-0316 Dear Ms. Ellifritt, This letter is in response to your written request for an extension to Permit D15-0316. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through January 19, 2017. If you should have any questions, please contact our office at (206) 433-7165. Sincerely, Nhm�j Rachelle plll� Permit Technician File: Permit No. D15-0316 WAPermit Center\Extension Lettenr\Permits\2016\M16-0013 Permit Extension #I.docx 6300 Southcenter Boulevard, Suite #100 9 Tukwila, Washington 98188 0 Phone 206-431-3670 • Fax 206-431-3665 Rachelle Ripley From: Deb Ellifritt <debe@siccwa.com> Sent: Friday, July 15, 2016 11:14 AM To: Rachelle Ripley Subject: Permit D15-0316 Hello Rachelle, We are requesting an extension regarding permit D15-0316 due to the work being incomplete. Should you have any questions, please let me know. Thank you. Regards, Deb Ellifritt Practice Manager Seattle Integrative Cancer Center 202 Andover Park E. Suite #3 Tukwila, WA 98188 Ph: 206-588-1722 Fax: 206-242-2275 G Request for Extension # Current Expiration Date: t Extension Request: Approved for `�� days Denied (provide explanation) Sig/nature/Initials l 1 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 6/ 1 /2016 LUCIA CHEN 200 ANDOVER PARK E TUKWILA, WA 98188 RE: Permit No. D15-0316 SEATTLE INTEGRATIVE CANCER CENTER 200 ANDOVER PARK E Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/19/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/19/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 04 ift, d (Z I t bt/ Rachelle Ripley Permit Technician File No: D15-0316 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 9 Phone 206-431-3670 9 Fax 206-431-3665 Joanna Spencer i From: Joanna Spencer Sent: Tuesday, January 05, 2016 10:30 AM To: Todd Reedy Cc: David McPherson Subject: RE: Sea Interactive Cancer Center @ 200 APE D15-0313 Thanks for clarification. Joanna From: Todd Reedy Sent: Monday, January 04, 2016 3:55 PM To: Joanna Spencer Subject: RE: Sea Interactive Cancer Center @ 200 APE D15-0313 Hi Joanna, Along with the RPPA outside in a hotbox for domestic premise isolation, we are tracking three internal RPPA's at that property but since they are on private property we are not sure what they protect. All the information we have for them is: -1.5" RPPA located in the Suite 3 mechanical room that the initial test report stated was for the HVAC system. -1.5" RPPA located in the Suite 3 mechanical room that just says is for in -premise protection. -1" RPPA located in the mechanical room for Suite 4. Their plumber may have to do some investigation to determine if one of the existing backflow preventers isolates the space for the new clinic. Todd I am happy to report that 200 Andover Park East is current on backflow preventer installation and testing. Todd From: Joanna Spencer Sent: Monday, January 04, 2016 9:11 AM To: Todd Reedy <Todd.Reedy TukwilaWA.goy> Cc: Joanna Spencer <Joanna.Spencer TukwilaWA.gov>; David McPherson <David.McPherson@TukwilaWA.gov> Subject: Sea Interactive Cancer Center @ 200 APE D15-0313 Good Morning Todd, PERMANENT FILE COPY Happy New Year! Are their backflows current? Joanna 1J15-O313 PERMIT CooRa COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D154W CGI (a DATE: 12/30/15 PROJECT NAME: SEATTLE INTERACTIVE CANCER CENTER SITE ADDRESS: 200 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: AT AWC Building Division �� -P Public Works 9 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved El Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Revision # before Permit Issued Revision # after Permit Issued W MN(I 'u Fire Prevention Structural ❑ (,VL- k4w 11* Planning Division Permit Coordinator ❑ DATE: 12/31/15 Structural Review Required ❑ 111Ia DUE DATE: 01/28/16 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 WE HONEY DO.COM LLC Page 1 of 2 Home 13span"ol Contact Safety & Health Washington State Department of Labor & Industries WE HONEY DO.COM LLC Owner or tradesperson Principals METZGER, ERIC WALTER, PARTNER/MEMBER METZGER, ERIC WALTER, AGENT Doing business as WE HONEY DO.COM LLC Search L&I A-Z Index Help My Secure ]Xl Claims & Insurance Workplace Rights Trades & Licensing 10035 Main St Rear office BOTHELL, WA 98011 425-775-6123 KING County WA UBI No. Business type 603 063 451 Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. WEHONHD895C3 Effective — expiration 02/23/2011— 03/17/2017 Bond ................. American Contractors Indem CO $12,000.00 Bond account no. 100292429 Received by L&I Effective date 12/09/2015 12/09/2016 Expiration date Until Canceled Bond history Insurance Capitol Specialty Ins Corp $1,000,000.00 Policy no. EV20150693-01 Received by L&I Effective date 11/17/2015 11 /18/2015 Expiration date 11/18/2016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Cause no. 14-2-33040-5SEA Dismissed ............................. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603053451&LIC=WEHONHD895C3&SAW= 01/19/2016 i RIRnLMNU, WA uouab PHONE: • (425) 672-8719 TX: _(425) 672-7182 AA\ITA^'r- . 1�.� ....1.ww.w... _ . 200 ANDOVER PARK EAST W160 ROOM NUMBER + DATUM REFERENCE, OR WOkK PLACE ® DOORNUMBER* �,A MULTIPLE INTERIOR . �► 1 A-7.3 ELEVATIONS WINDOW RELITE, NUMBE DETAIL ---� -CONSTRUCTION NOTE s�--..�,� DEMO NOTE 6 WALL TYPE. ® IDENTIFICATION .�. BUILDING SECTION WALL SECTION • TUCKWILA; WAS HINGTON ci ZONING: TUC z SEISMIC ZONE: 3 PROJEff DESCRIFFION' OCCUPANCY: B CONSTRUCTION: V-B SPRINKLERS - YES FIRE ALARM SYSTEM - - YES MINOR REMODEL OF A 1-STORY EXISTING OFFICE BUILDING BUILDING IS 1 STORY TO ADD THREE OFFICES, ONE STORAGE CLOSET AND -A DOOR SUITE ' OCCUPANT LOAD TO . HALL 106. ( 9' AREA. OCCUPANTS NO.OTHER CHANGES: Lu o BUSINESS: 4,630. SF/100- = 46 AREA OF REMODEL: 385 SQ. FT.. N x w _ MECH%ELECT. `295 SF/500 = 1 � Q SHELLED -IN: •3,025 _2890 SF/100 = ' 30 COMMON AREAS SF . w TOTAL OCCUPANTS:. 77 o 0 TOTAL AREA OF SUITE: 10,840 SF: o TOTAL AREA OF BLDG.. 32,156 SF PROJECT MUST COMPLY WITH THE FOLLOWING CODES: INTERNATIONAL BUILDING CODE (2012) INTERNATIONAL, MECHANICAL CODE (2012) SITE P LAN UNIFORM PLUMBING CODE (2012) SCALE:. 1" - 40'• INTERNATIONAL. FUEL GAS CODE (2012) NORTH ; .NATIONAL. ELECTRIC C ELECTRICCODE ( ) ' EXISTING 'BUILDING CODE (2012) INTERNATIONAL ENERGY -CODE (2012), (CHAPT. 51-11 WAC) WASHINGTON 'STATE REGULATIONS FOR BARRIER -FREE GENEW NOTESFACILITIES (COHAP.T. 51.40.1100 WAC), ANSI 117.1 (2009) 1. THE CONTRACTOR IS REQUIRED TO COMPLY WITH ALL APPLICABLE REGULATIONS, CODES AND ORDINANCES. W 2. CONTRACTOR SHALL KEEP AREAS UNDER CONSTRUCTION CLEAR OF DIRT AND DEBRIS CAUSED. BYRA DEMOLITION AND SHALL STCRE CONSTRUCTION MATERIALS AND EQUIPMENT IN AREAS DESIGNATED. BY THE OWNER'S AUTHORIZED REPRESENTATIVE. 3.. -DIMENSIONS ARE TO FINISHED_ FACE OF PARTITION U.N.O. ARCHITECTURAL DRAWINGS E-+ 4. COORDINATE WITH OWNER ALL OPERATIONS SUCH AS AREAS USED FOR MATERIALS T1.0 TITLE SHEET W/ SITE PLAN, ' PARTIAL FLOOR PLAN, NOTES W w STORAGE, ACCESS TO AND FROM WORK, SPECIAL CONDITIONS OF NOISY OPERATIONS. A1.0 DEMOLITION PLAN, FLOORPLAN, REFLECTED CEILING PLAN V) 5. EXISTING CONDITIONS DAMAGED OR REMOVED AS A RESULT OF ALL WORK REQUIRED DETAILS, NOTES E , 0 4j w TO BE DONE UNDER THIS CONTRACT SHALL BE REPAIRED OR REPLACED TO ORIGINAL 4e .P CONDITION AND FINISHED TO MATCH ADJACENT FINISHES. Q, a, 1 .6. ALL PATCH . PAINTING SHALL BE. EXTENDED TO THE NEAREST WALL OR CEILING BREAK, ,o FROM FLOOR TOP OF. BASE TO CEILING ON WALLS AND FULL WIDTH OF CEILINGS EW Z UNLESS NOTED. OTHERWISE. • .. icy--• 7. FILL ALL .HOLES AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH RESULT FROM THE INSTALLATION OF NEW WORK AND REMOVAL OF w � • EXISTING MATERIALS AND EQUIPMENT ► 7 • REQUIRED BY THIS CONTRACT, INCLUDING MECHANICAL AND ELECTRICAL. PATCHED AREAS SHALL MATCH THE MATERIALS, FINISHES AND LEVELS ADJACENT. � : � � • O MCINo � 8. OWNER SHALL SELECT ALL FINISHES, ADHERING TO BUILDING STANDARDS WHERE APPLICABLE. .. 0 0 W•. 0 Ea PROJECT ' Permit ' EVANS BLACK DR. LOCATION EI Plan review apProuai is subject to errors and omissions.. :'JAN 04 2016 J J �11'�proval of €orf3tructinn documon#s does not authorize BAKER BLVD. the violati�an r.�f tw� z TUKV�►1►=►� � any adopted coda . r ordinance.Receipt PUBLIC WORK" ;�,� h� of approved Fiold � w PY c diti ns is acknowledged: - . °- _i- w 7n a c :c' Date: I a STRANDER BLVD. c'pE` r ! V ti o 'Nd' , - CI Of c�y�i C?i'°� O I LsY JVILA � h/ Tul��ii� � ' W . 5 { � � DEC0 5 BUILDING DIVISION. � EC 1 S 4 L6 91 PERMIT CE ER .�1. Z_IAArt O Dob of issue 1 REWIONS III 5t fe to the uvp V nutr,n Pnproval o3 PARTIAL FLOOR PLAN' ✓l�iIGYF1=Division. NOT TO SCALE ; . ` � will req ,fire a new plan suit l ..� rr,uy hi.dude adclitianal plan rovtaw less. NORTH � �'�t. ,3•t 7 't U .,, � P i',tY . k tl ;.@. .3 c � a� ��� t. F. ,r �$ t;; b # ar r3,•T 1. .ws. a�. }. ,�.2 �,r.t 9z"3 ^n. „xa,w ,•m:. ,,,. t x•u .`,}z t a *k ,. .�M „t:,ttit3r`, /..,�P.k.r�l 'iP�£h�aa�:!� �, �" •.• i S d, E hot r„s 3 c...., . '� YN µ:. 'r DEMOLITION PLAN N SCALE: 1 /8 = 1 -0 DEMOLITION NOTES 0 1. REMOVE NON -RATED WALL IN AREA OF NEW DOOR. CONSTRUCTION NOTES ❑ 1. NEW INTERIOR NON -RATED WALL. SEE 1 /A1.0 2. NEW 3'-0" SOLID CORE SLAB DOOR. FINISH PER BUILDING STANDARDS. DOOR HARDWARE (DOORS 101, 102, 103, 104): 3 EA. BUTTS 1 SET SILENCERS 1 EA. LOCKSET 1 EA. STOP DOOR HARDWARE (DOOR 106): 3 EA. BUTTS 1 SET SILENCERS 1 EA. LATCHSET 1 EA. CLOSER 1 EA. STOP NOTE; HARDWARE ON DOOR 106 MUST ALWAYS ALLOW PASSAGE INTO HALLWAY 108. DOOR HARDWARE TO MEET REQUIREMENTS OF A.D.A. AND WAC CHAPTER 51:40.1100 FOR ACCESSIBILITY. HARDWARE MANUF. AND FINISH PER BUILDING STANDARDS. 3. ROOM FINISHES (PAINT, CARPET, BASE, CEILING TILE) TO BE SELECTED BY OWNER. 4. SUPPLY DIFFUSER IN CEILING GRID. 5. 2 x 4 FLUORESCENT LIGHT FIXTURE. 6. MEDIUM DUTY SUSPENDED CEILING GRID. SEE 2/A1.0. 7. RETURN GRILLE IN CEILING GRID 8. ILLUMINATED :EXIT SIGN ABOVE DOOR. 3-5/8" x 20 GA STEEL STUDS ALTERNATING 48" O.C. ATTACH W/ (2) 1 /4" SM SCREWS INTO TOP ABOVE W/T(2) 1 /4"A S SCH TO OD FRAMING SCREWS CARRY GWB 6" ABOVE CEILING LINE. T-BAR CEILING 3-5/8" x 20 GA STEEL STUDS AT 16" O.C. 5/8" TYPE 'X' GWB EACH SIDE. 3-1/2" SOUND BATT INSULATION 1 /4" DIA. POWDER -DRIVEN PINS INTO CONCRETE SLAB AT 48" O.C. INTERIOR WALL SECTION I SCALE: 1" = V-0" UNISEX R RSEX HALL 10 O O HALL HALL ul [D-/OFFICE 0) 1o1 PHARMACY OFFICE OFFICE 10 2 UNISEX R.R. -31 FUTURE OFFICE i' INFUSION m 103 °) ROOM Ill BREAK ROOM STOR. STOR. 104 10 HALL 107 FLOOR PLAN i• NOTE NO. 5 45 SMAX TYP NOTES: WALL LEGEND: EXISTING WALL TO REMAIN NEW INTERIOR WALL NOTES NO. 3 & 6 4 TURNS MIN. WITHIN 1-1/2" NOTE NO. 5 TYP. 2" MAX TYP CROSS 'T' MAIN RUNNER 1 45 `MAX TYP REFLECTED CEILING PLAN SCALE: 1 /8" = V-0" 8" MAX -+�- 12 GA. WIRE 2" X 2" WALL ANGLE MAIN RUNNER ATTACHED TO (2) ADJACENT WALLS. GRID SHALL BE UNATTACHED TO THE REMAINING (2) WALLS. CEILING WALL INTERSECTION NOT TO SCALE 1. SECTION 808.1.1.1 OF THE INTERNATIONAL BUILDING CODE REQUIRES THAT SUSPENDED 6. SUSPENSION WIRE: 12 GA. GALV. SOFT -ANNEALED MILD STEEL WIRE ENCASED IN 1/2" DIAM. ACOUSTICAL CEILINGS BE INSTALLED IN ACCORDANCE WITH ASTM C 635 AND ASTM C 636. CONDUIT (FOR UPLIFT RESTRAINT); SECURE WIRE TO MAIN RUNNER WITHIN 2" OF CROSS 'T'. CONDUIT TO OCCUR AT EVERY LATERAL BRACING CLUSTER AND SUSPENSION WIRES TO OCCUR AT 2. COMPONENTS OF THE SUSPENDED CEILING SYSTEM SHALL MEET THE REQUIREMENTS OF ASTM E 580/E 580M, 4'-0" O.C. MAX. EACH WAY. . ASCE 7-05 AND CEILINGS AND INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION (CISCA). 7. SUSPENDED CEILINGS EXCEEDED 1,000 SQ. FT. IN AREA MUST BE SEISMICALLY BRACED 3. THE COMPRESSION STRUT SHALL BE VERTICAL, AND SHALL NOT BE MORE THAN 1 IN 6 OUT OF PLUMB. TO THE BUILDING STRUCTURAL SYSTEM. STRUTS MUST BE POSITIVELY ATTACHED TO THE CEILING GRID MAIN RUNNER AND THE STRUCTURE ABOVE. S. SUSPENDED CEILING GRID SHALL BE ATTACHED TO (2) ADJACENT WALLS. GRID SHALL BE UNATTACHED 4. EACH STRUT MUST BE ACCOMPANIED BY A SPLAY WIRE, LOCATED IMMEDIATELY ADJACENT TO AND TO THE REMAINING (2) WALLS. WITHIN 2" OF THE STRUT. 9. ALL WIRE TIES TO BE (3) TIGHT TURNS AROUND THE WIRE, WITHIN A SPACE OF 3'. VERTICAL WIRE TO BE SPACED MAXIMUM OF 4' ON CENTER. 5. LATERAL BRACING CLUSTER: (4) 12 GA. GALV SOFT -ANNEALED MILD STEEL WIRES SECURED TO MAIN RUNNER WITHIN 2" OF CROSS 'T' AND SPLAYED 90 DEGREES FROM EACH OTHER AT 10. REFERENCE THE NORTHWEST WALL AND CEILING BUREAU TECHNICAL BULLETIN 401, REVISED 10-09 45 DEGREES MAX. ABOVE HORIZONTAL. CLUSTERS PLACED 12'-0" O.C. MAXIMUM AND NO FURTHER THkN FOR ADDITIONAL INFORMATION. 6'-0" FROM EACH WALL. WIRES SHOULD BE TAUT WITHOUT CAUSING CEILING TO LIFT. r;--�_SIEISMIC BRACING AT CEILING GRID NOT TO SCALE FABRICATED STRUT ALLOWABLE LENGTH TABLE MATERIALS TRADE SIZE ALLOWABLE LENGTH EMT* IMC* OR RMC* PIPE 1/2" 5'-10" 4'-4" 3/4" 7'-8" _7" 50 1" 9'-9" _ 1I 71-0 METAL STUD SINGLE 1-5/8" x 20 GA 12'-0" DOUBLE BACK-TO-BACK 1-5/8" x 20 GA 15'-0" SINGLE 2-1/2" x 20 GA 13'-6" DOUBLE BACK-TO-BACK 2-1/2" x 25 GA. 15'-0" *EMT --ELECTRICAL METALLIC TUBING IMC--INTERMEDIATE METAL CONDUIT RMC--RIGID METAL CONDUIT -�— ¢#12 GAGE HANGER PROVIDE AT EACH CORNER GA. HANGEERSRS IF , ' `, OR (2) WIRES WITH f: LIGHT FIXTURE IS I !: HEAVY- DUTY GRID LESS THAN 56 I rr SYSTEM. LBS. AND 4-##12 I r .: .ff�• w.;�1 GA. IF LIGHT LIGHT FIXTURE EXCEEDS `" fr FIXTURE 56 LBS. �` /�f�� fr` LIGHT SHALL BE ATTACHED TO THE CEILING SYSTEM WITH POSITIVE CLAMP DEVICES. LIGHT FIXTURE BRACING NOT TO SCALE 0 uj ��z p uj zn 7 C¢,:x Lu Ix EW-+ 0 U � z C�J 0 W O ►-� ;� of .0 LL w z •p Q w Q J oa o :2F_ a z o 0 E-+ <C En N E-+ z 0 W Ix J J �n 0 N °f ao V / ao °0 I I w— z _ rn �� 0 a = ultn y V� �C0 V) a o. L_qq!!� IA LO 0 2