Permit EL15-0216 - SCHOOL EMPLOYEES CREDIT UNION - BRANCH CIRCUIT PANELS
SCHOOL EMPLOYEES CREDIT UNION 5200 SOUTHCENTER BLVD SUITE 100 EL15-0216 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov ELECTRICAL PERMIT Parcel No: 1157200013 Permit Number: EL15-0216 Address: 5200 SOUTHCENTER BLVD 100 Issue Date: 5/15/2015 Permit Expires On: 11/11/2015 Project Name: SCHOOL EMPLOYEES CREDIT UNION Owner: Name: GROW INVESTMENTS LLC Address: 5200 SOUTHCENTER BLVD #140 , TUKWILA, WA, 98188 Contact Person: Name: CHE FORTALEZA Phone: (206) 682-0884 Address: 502 SECOND AVE, SUITE 2800, SEATTLE, WA, 98104 Contractor: Name: MERIT ELECTRIC INC Phone: (425) 315-8840 Address: 12201 CYRUS WAY STE 105, MUKILTEO, WA, 98275 License No: MERITE1044BQ Expiration Date: 1/20/2014 Lender: Name: Address: DESCRIPTION OF WORK: APPROXIMATELY 16,000 SQ FT OF TENANT IMPROVEMENT ON PARTIAL FIRST AND SECOND FLOORS. EXISTING ELECTRICAL SERVICE TO REMAIN. NEW DISTRIBUTION AND BRANCH CIRCUIT PANELS BEING ADDED Valuation of single family: $0.00 Fees Collected: $1,407.06 Valuation of mf/comm: $58,000.00 Type of Work: TENANT IMP Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature:1�q!� W t'I [ +WV I Da I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. CC Signature:Z� Date:S f�1 rs Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKW._ Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htlp:/hvww.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 11572000130020 Site Address: 5200 Southcenter Blvd. Tukwila WA, 98188 Suite Number: 100, Floor: 1,2 Tenant Name: School Employees Credit Union New Tenant: ® .....Yes ❑..No PROPERTY OWNER Name: School Employees Credit Union Address: 5200 Southcenter Blvd. City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Che Fortaleza, CR architecture + design Address: 506 Second Avenue Suite 2800 City: Seattle State: WA Zip: 98104 Phone: (206) 682-0884 Fax: (800) 469-4949 Email: c-PH a1GZa a Gr- a &W t ec.+s eon, ELECTRICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): S 58,000 Scope of Work (please provide detailed information): Approximately 1.6,000 SF of Tenant Improvements on partial I st and 2nd floors. Existing electrical service to remain. New distribution and branch circuit panels being added. Will service be altered? ❑ Yes ® No Adding more than 50 amps? Yes ❑ No Type of Use: Office Tyne of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ® Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served bv- ❑ Puget Sound Energy ® Seattle City Light H: W pplications\Forts-Applications On Linet2014 ApplicationsmCctrical Pcrtnit Application Rc%iscd 1.1.14.doex Revised: January 2014 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat)................................$59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration......................................$81.90 (no added/altered circuits) ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $ 68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals....................................................................$80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Che Fortaleza, CR architecture (authorized agent) Date: 03/09/2015 Day Telephone: (206) 682-0884 Mailing Address: 506 Second Avenue Suite 2800, Seattle, WA 98104 City H:VApplicalio \Foima-Applications On LincQ014 ApplicationmElecdical Permit Application Revised 1-1-14.docx Revised: January 2014 bh State Zip Page 2 of 2 DESCRIPTIONS ACCOUNTQUANTITY PermitTRAK PAID $261.50 D15-0062 Address: 5200 SOUTHCENTER BLVD 100 Apn: 1157200013 $66.50 DEVELOPMENT $66.50 ADDITIONAL PLAN REVIEW R000.345.830.00.00 1.00 $66.50 EL15-0216 Address: 5200 SOUTHCENTER BLVD 100 Apn: 1157200013 $65.00 ELECTRICAL $65.00 ADDITIONAL PLAN REVIEW R000.345.830.00.00 1.00 $65.00 M15-0025 Address: 5200 SOUTHCENTER BLVD 100 Apn: 1157200013 $65.00 MECHANICAL $65.00 ADDITIONAL PLAN REVIEW R000.345.830.00.00 1.00 $65.00 PG15-0029 Address: 5200 SOUTHCENTER BLVD 100 Apn: 1157200013 $65.00 PLUMBING $65.00 ADDITIONAL PLAN REVIEW R000.345.830.00.00 1.00 TOTAL FEES • . $65.00 1 Date Paid: Thursday, June 04, 2015 Paid By: SCHOOL EMPLOYEES CREDIT UNION Pay Method: ACCOUNT Printed: Thursday, June 04, 2015 1:11 PM 1 of 1 rpFf f SYSTEMS DESCRIPTIONS PermitTRAK ACCOUNTQUANTITY PAID $1,156.47 EL15-0216Address: 5200 SOUTHCENTER BLVD 100 Apn: 1157200013 $1,156.47 ELECTRICAL $1,102.35 PLAN CHECK FEE R000.345.832.00.00 0.00 $20.00 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,082.35 TECHNOLOGY FEE $54.12 TECHNOLOGY FEE TOTALPAID R000.322.900.04.00 0.00 $54.12 6.4 Date Paid: Friday, May 08, 2015 Paid By: SCHOOL EMPLOYEES CREDIT UNION Pay Method: CHECK 0002184881 Printed: Friday, May 08, 2015 11:42 AM 1 of 1_,o: ,n �,r srsrtMs Date Paid: Monday, March 09, 2015 Paid By: SCHOOL EMPLOYEES CREDIT UNION Pay Method: CHECK 2180207 Printed: Monday, March 09, 2015 3:47 PM 1 of 1 Cr-SYSTEMS i INSPECTION RECORD l Retain a copy with permit INSPECTION NO. PERIMIT N0. CITY OF TUKWILR BUILDING DIVISION 6300 Southcenter Blvd., 4100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request line (206) 438-9350 Project: y Type of Inspection: Address: [late Called: ' Special Instructions: Date Wanted: a.m. m. Requester. Phone No: Approved per applicable codes. Corrections required prior to approval. IInspector: L-7 Alm IDate: a 3 /(` /(( I REINSPECTIMA FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD INSPECTION N0. Retain a copy p PERMIT O. with permit � NO. CITY CITY OF TUKWILA BUILDING; DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 1"ype of Inspection: M Address: Date Called: Special Instructions: Date Wanted: ' a.m.. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. W INSPECTION RECORD ��lS �(p Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Project: Type of Inspection: Address: 5)00 Date Called: Special Instructions: Date Wanted: 1 a.rn Requester: Phone No: r, —7_ V—, Approved per applicable codes. Corrections required prior to approval. t___I paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. pt No.: I Date: 'Q INSPECTION RECORD // (� Retain a copy with permit I tt�7 INSPECTION NO. PERMIT NU. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: p Gi-Fr� f CY-607 Type of Inspection: Address: , l_ , Date Called: Special Instructions: Date Wanted:#-�y a. p.m. Requester: Phone No: � Q 3�Q F16 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION -RECORD Retain a copy with permit�"` 7 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proje 344=--6L Type of Inspection: ��� L I Address: Date Called: Special Instructions: Date Wanted: 7 P Requester: Phone No: c o Approved per applicable codes. LJ Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit��� INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:5 Type of Inspection: p to Address: Date Called: Special Instructions: Date Wanted: 7 a p.m. Requester: Phone No: p Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: ru �, ✓' s�- �� k4 9 2_ 6,z Inspector: ( Date: 0 7 2 �S REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 50, Retain a copy with permit 'Q INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: ' �^ Date Called: Special Instructions: Date Wanted: Z p.m Requester. Phone No: ❑ Approved per applicable codes. LJ Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. j INSPECTION RECORD Retain a copy with permit r INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: f � Type of Inspection: a ✓�l Address: Date Called: Special Instructions: Date Wanted: a �7-7i p.m. Requester: Phone No: ElApproved per applicable codes. E Corrections required prior to approval. COMMENTS: a r` r--Z-o © -114 % Inspector: _ /111 /ti �� (uace: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �° cJGI i� f7L LD Type of Inspection: hD'l4 f i Address: S�pc7 S. : gL aI100 Date Called: Special Instructions: Date Wanted: a.m. P.M.. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: OL LJ c—t r" o Inspector: 44 Date: 06Lf I �pN REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: i4 Address: (R Q Date Called: Special Instructions: Date Wanted: a.m. Requester: H� Phone No: ❑ Approved per applicable codes. LJ Corrections required prior to approval. El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD L/ ,� 6 Retain a copy with permit i� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: / Type of Inspection: JLI (av Address: Date Called: Special Instructions: Date Wanted: (� a. P.M. Requester: Phone No: Approved per applicable codes. V) Corrections required prior to approval. nspector: REINSPECTION FEE REQUIRED. Prior to next inspection. #ee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit o D� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: 2'oc3 6� e ., L- " 100 Date Called: Special Instructions: Date Wanted: a. p.m. Requester: Phone No: 11 Approved per applicable codes. Corrections required prior to approval. COMMENTS: (� oolz, C� Z0 -c inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 1 /4/2016 CHE FORTALEZA 502 SECOND AVE, SUITE 2800 SEATTLE, WA 98104 RE: Permit No. EL15-0216 SCHOOL EMPLOYEES CREDIT UNION 5200 SOUTHCENTER BLVD, STE 100 Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/1/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/l/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician Fite No: EL15-0216 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 CASE ENGINEERING Consulting Electrical Engineers May 15, 2015 Electrical Plans Reviewer City of Tukwila Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 Project: SECU Tenant Improvements Electrical Permit #EL15-0216 Subject: Permit Resubmittals As a result of the bid process, the following revisions have been made to the SECU Tenant Improvement Permit Set dated 03/06/15: Choot imn1 • Updated energy code compliance form with new fixture types and quantities • Revised lighting fixture schedule • Added lighting control schedule • Added General Note for all sheets • Added symbols to legend Sheet E201 • Revised outlet layout to match architectural changes Sheet E202 .• Revised outlet layout to match architectural changes Sheet E301 • Minor lighting revisions to align with RCP changes • Added dimming fixtures to comply with Washington State Energy Code Sheet E302 • Added dimming fixtures to comply with Washington State Energy Code RECEIVED CITY OF TUKWILA PERMIT CENTER Sheet EL401 • Updated emergency egress lighting level calculations to match with revisions to lighting plan Sheet EL402 • Updated emergency egress lighting level calculations to match with revisions to lighting plan 19515 North Creek Parkway, Suite 302, Bothell, WA 98011 Phone:425-402-9400 Fax:425-402-9402 SECU Permit Resubmittal May 15, 201S Page 2 of 2 Sheet FAni • Partial Basement Electrical Plan — Corrected name of Panel PD • Existing Riser Diagram — Corrected ground size to Panel PD • Updated Load Summary for 1200 amp Bussed Gutter Sheet E901 • Updated panel schedules Please let me know if you have any questions or need additional information. Thank you, Michael Case, P.E. file name PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0216 DATE: 03/09/15 PROJECT NAME: SCHOOL EMPLOYEES CREDIT UNION SITE ADDRESS: 5200 SOUTHCENTER BLVD - SUITE 100 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 3� A4c 3-1�- K Building Division 0 Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Fire Prevention ❑ Planning Division ❑ Structural ❑ Permit Coordinator r DATE: 03/12/15 Structural Review Required ❑ DATE: DUE DATE: 04/09/15 Approved with Conditions Z Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 'aERMIT CORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0216 DATE: 05/19/15 PROJECT NAME: SCHOOL EMPLOYEES CREDIT UNION SITE ADDRESS: 5200 SOUTHCENTER BLVD Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: if; 04 9? Building Division Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approvaUreview required) REVIEWER'S INITIALS: Fire Prevention ❑ Structural ❑ Planning Division ❑ Permit Coordinator ❑ DATE: 5/21/2015 Structural Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 6/18/2015 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PROJECT NAME: V • . PERMIT NO: V ©�F SITE ADDRESS: 7r S el('a��%S ORIGINAL ISSUE DATE: 15; liff REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DA j STAFF JNITIALS 1 9 � Summary of Revision: MA0 6�� 6 k�� V2 -- I A/ Received b . II V REVISION NO. DATE RECEIVED STAFF INITIALS ISSUEb DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: hq://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 05/18/2015 Plan Check/Permit Number: EL15-021.6 Response to Incomplete Letter # Response to Correction Letter # ✓ Revision # 1 after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: SECU Tenant Improvements Project Address: 5200 Southcenter Blvd. Tukwila, WA 98188 Contact Person. Che Fortaleza Summary of Revision: Revisions as a result of the bidding process. See attached narrative. Phone Number: (206) 682-0884 MAY 19 2015 PERarcEmm Sheet Number(s)• Listed on attached narrative. "Cloud" or highlight all areas of revision including date of revision P Received at the City of Tukwila Permit Center by: 3:1 '--Entered in Permits Plus on �C H:\Applications\Forms-Applications On Line\2010 Applications\7-2010- Revision Submittal.doc Revised: May 2011 MERIT ELECTRIC INC Pagel of 3 Home Inicio en Espanol Contact Safety (rWashington State Department of .� Lab©r & Industries MERIT ELECTRIC INC Search L&I A-'L .Index Help Mp Secure 1 &I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 12201 CYRUS WAY STE 105 MUKILTEO, WA98275-5735 Principals 425-315-8840 LANUM, JACK D, PRESIDENT SNOHOMISH County LANUM, LAURA C, VICE PRESIDENT EVERSON, CHRISTINA M, SECRETARY RONALD G HOUSH, AGENT DEFAYE, PHILIPPE MARC, PRESIDENT (End: 01/11/2010) WILSON, CHRISTINA, SECRETARY (End: 01/11/2010) DEFAYE, PHILIPPE MARC, TREASURER (End: 01/11/2010) Doing business as MERIT ELECTRIC INC WA UBI No. Business type 601 680 785 Corporation Governing persons JACK D LANUM PHILLIPPE M DE FAYE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ........._.................................................... Meets current requirements. License specialties GENERAL License no. MERITE1044BQ Effective — expiration 01118/1996— 01 /20/2016 Designated administrator LANUM, JACK D License type Master Electrician Bond ................. CBIC Bond account no. SH3803 Received by L&I 08/27/2007 Active. Meets current requirements. License no. LANUMJD978D4 $4,000.00 Effective date 06/14/2007 Expiration date https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601680785&LIC=MERITEI044BQ&SAW= 5/15/2015 Q M U (f)Z Z- aU) �_ �_ ZU 0 W U - U Z W' Oa J J 2U) X(1) on zo+ W J �_ 0 00 ZF_ �_Z Z W W Z �0 U U O �_0 U W � �_X = W W W �� W �- ZZ) 0 z H U�: � ¢ =n- o W I _ Qa J W 5 U)- Z)= Er U + - W = J 3 OX U 0 LL LL 0�_ U 11 W W EL 0 oof nfa av W' >U !n W Z)a J U) UW W H 2 IL z Q m Q= o U Of�; D W O= ; z0 O d X N W 0 ui F-o fA W I Z Z) T W o: v 2O - �0 U W 0. 0a W 00 �- U U ~O = W 0, F-m a LIGHTING FIXTURE SCHEDULE WATTS1 TYPE DESCRIPTION LAMP FIXT ......... ......:.. ......... . ....................................... .....:. INTERIOR! ... .. _ .: ... .. ..,......................................................_.................................. 2x4 RECESSED DIRECTIINDIRECT TROFF€R, NOMINALLY 2' x 4' ........ ......................... ........:__ ................... .. .. .........C.....1I. . .. ..........:...... WITH EXTRUDED ACRYLIC LENS. .:.. ........................................ :. .:.. .. ....... ...-:........... .. ....... .:..... .. ..... ......... ....... DAY BRITE' SOFT TRACE' 2STG228 SERIES .......... .................... ......... ..._.... ...... .............. ... ........... _..................................... .......: ......... ............... ...;.. ......... _............................. _ FINELITE HPR 2 2x4 SERIES _..... ....................... ::..:;... .... ................................ LITECONTROL GDLHE SERIES , ........ :. . ......... ... AXIS WA24'SERIES HE WILLIAMS SPX SERIES .. C1 D .. ... ............... SIMILAR TO C1 EXCEPT WITH o- 0V DIMMING BALLAST_ 2-F20T� .... 64 ............................... C1X .... ............ .................................................................. ...................................................... ........... ......... SIMILAR TO C1' EXCEPT WITH EMERGENCY BACKUP BALLAST. .... E ........................................... F28T5 2.........................64.......... .. ..................... C1DX ... .. ..:_........................................................................................ SIMILAR TO C1 EXCEPT WITH 0 10V DIMMING BALLAST AND EMERGENCY .... ........... ...... ................ 2-F28T5 .............................. 64 ...................................................... ......... ......... . BACK UP BALLAST. ........................ F1 _..........................................................................................................................................................................._........................................................................................_................._.............__.........._............I.._..............-..... RECESSED 6" LED DOWNLIGHT WITH SELF FLANGED MATT .. ...... .................. .. LED ....... ... .... ...... ... 28 .... ........................ .. ......... DIFFUSE REFLECTOR AND 1800 LUMENS MINIMUM AND WITH .......... ....................... ........ ------- ...................... .............. .............. ............... .............................. ............... ............. ...... .... ........................... -........ ...... .... ...... ......... ...... ........................ .................................... ................ ..................... ......... ...... MEDIUM DISTRIBUTIONi 3500K COLOR TEMPERATURE WITH ,....................... ......... ........... ...................... ..........................:... ......................................................................................................................... CRi MIN NIMUM I_1_11111.1111111 I— -MUM. GOTHAM 35186ARMDMDLD SERIES ....................... ................................................................................. :.............: .:.................. .......... .................. .............................................. HE WILLIAMS LED60PH2O835 SERIES ............................ ................. .............: ... .... :.............. .. ... .. ....................... PATHWAY 6VLBV2035KM SERIES .................... ._....... ......... .._ ............. ..... ..:.... .......... _.......... ....._..........: .............. PORTFO RIES .........................UO..LD6A20' SE.....:.. ....... ... ... ... .............. .... F1 D ..................................................................:::................................................................................................:::. ..... .. _.......:_ ,......::.::::...: ... .... _. ...... ........ .......................... ..................... SIMILAR TO F1 EXCEPT WITH 0-10V DIMMING DRIVER. ........................................................... LED .............................. 28 ...................................................................................................................... F1X _...........................................::...................................................................._..................................-.................... SIMILAR TO F1 EXCEPT WITH INTEGRAL EMERGENCY BACKUP. ...........:................................................. .. ......... .............. ........... ................ ..... .... ........................ ......... ........................................... ........... 1-CFTR32 ............................ ................................ .... I ........................ ....... F1 DX ............................................... SIMILAR TO F1 EXCEPT WITH 0 10V'DIMMING DRIVER AND INTEGRAL .. .. ,........ ......... ......... .................................................. ......................................... 1-CFTR32 ... .......-...................................... 36 ................ EMERGENCY BACK UP BALLAST. ... ...... ......... ......... ......... ..... .. ....... .. ............ .................................................. .............................................................. ........................................... -F2..........DECORATIVE ... PENDANT WITH' ROUND SHADE. SHADE 'NOMINALLY .: _ .. ..............................................-....... LED _ ....;.. 30 .:..:: . .:... .......... .. ... .. . :.:.. .. ...; .::..., ..:.... WITH 20" DIAMETER BY 6" HIGH SHADE WITH 6' CORD. .... .. - ....:. .......:. .:.: ....... : ............. ... .:: .:..- . ....... ........ . _ .. ......... .:.... _ TECH LIGHTING ZHANE 70OLSZHN38SLED NO ALTERNATE .... ... ... ».... ......1.. F2D .-: .... :......::....."",..:... ..........:....:...:...:..::.::............:...... ... SIMILAR TO F2 EXCEPT WITH 0-10V DIMMING BALLAST_ ,.,,..........:.:.:.....:...:::.....::::, 1-CF18D GU24 ....::. 18 F3 .... _ ...... .. , ......... ......._ .. .... ..... .... ........: ........................... MONO POINT DECORATIVE LOW VOLTAGE PENDANT WITH 6OW REMOTELY ............................................................... 1-8W LED BI PIN 50 ................................................................................................................................................................................................................................................................................................................................................................................................. MOUNTED TRANSFORMER. 2-1/2" DIAMETER x 10" HIGH .:..... .....: .. .:.... CYLINDER._ FIXTURE AND HARDWARE TO BE SATIN NICKEL. ......: ....... ...... ., .. ...:::.:::.. .. ",.." , .:.... ..... .. , ........ .. TECH LIGHTING 70OMPPPRSS-LEDS830 SERIES NO ALTERNATE „ .:.:. .:. , ..:.:.: . .... . .......... . F4 ... .. »....... : .. ,-» ... . ... RECESSED ADJUSTABLE 4" LOW VOLTAGE ACCENT.LIGHT. TOOL LESS 1-50W MR16 ..:. 50 .......... .. . " ... ",,., 0-40 VERTICAL AND-355 HORIZONTAL LAMP ADJUSTMENTS., INTERNAL ,... ..... _ ...... I-- ... ..... .. . ........ ... .., ...- ........: .. .:.....:...................... .:.. ......_ HOUSING PAINTED BLACK. COORDINATE LAMP DISTRIBUTION ..:: ..::..::. :..: : ... ..:::..:.. ...:, ....... :.-1-1...:.. :. .... ........ ..,:.. ......... :::. .: WITH OWNER PROVIDE ART WORK PRIOR TO ROUGH IN -::. ... ....: :::..1... .> .. .- .:: . ... ..:: .. :. .. _: .. ...- .::.::....: .:........... GOTHAM DLVADJ4ACLS SERIES .... ... ................. .......... ,.:.:. .::.:: ..........................:.... ........... ........ .:. ...............................................:. .................... ...............:.................................... JUNO LV4MR SERIES ... .:.. ... :.:.... ..:. ...::::., �1.11,11,111,111-11.......:..:... ..:: PRESCOLITE A4SMR`SERIES .:.:. ...:—.1..... ».. .::.....:::. ..... .:. .:» ,... » . ...:: . :::. ::.:-,,.. :......... ,....:.. ....... . .::. PORTFOLIOH7493TSFRIES F5 ._ . .. . ...:::::: ...:::::. .....:::.................... MONO POINT DECORATIVE LOW VOLTAGE PENDANT WITH 6OW REMOTELY ::...... -,:... _... ..... ,., ... ::::.::: LED ...;: .. -..::;. 8' -.:.."I. .,...:.. I ................1..1.........................::: .. .. .. . .:..;;; .:_ .:::. .,. ..1-1-........ MOUNTED TRANSFORMER. 2.6" DIAMETER x 10.1" HIGH CYLINDER _ ..... ... .:..: ... .. ..... .:.: .. .. ......... ........:...: ..... .::...... .::..::.. ............ GLOSS BLACK FINISH WITH V SILVER CORD , ..... ...:...:.. ........ ... ........... ......:.. ...:.. .: ..... ...... ... ..: ...::::....................................... TECH LIGHTING 70OMPRVLBS-LEDS830 SERIES NO ALTERNATE ........ ............................................... .................... .......... F6 DECORATIVE PENDANT RU N D S WITH OHADE. SHADE NOMINALLY ;.::. ..... 1-CF18D GU24 18 WITH 20" DIAMETER BY 6' HIGH SHADE WITH 6' CORD. ... :;..... ..... :: :::: ..:....::::: .::... .:... ....:...:........:::.. .::. .. .:::. ........ ... .. ....... ........... ....:................ .. ..... ..... ...... . . TECH LIGHTIN1-1.11111.11-1.1111G 700TDMULPWS-CF NO ALTERNATE ...... ......... .....: ....... F6D .:::... .. ......... .. ..:: .................... ...............:. ... ..... .... SIMILAR TO I -1F6' EXCE1111--1111-1-PT WITH DIMMING LAMP ....................... 'I-CF18D GU24 .... 18 . X1 ..... .,,, ... .:..: :. :.::. :.:.. .. .. .. ....... ,. ,I..","..,...,.-"......,...,..-,--,. EMIT SIGN' WITH INTEGRAL BATTERY PACK GREEN STENCIL FACE :::.::::. :::::.:::_ .... _ :::...._ LED 5 ......... .....:::. .... ... ...._ ... ... ... .....:::. ......... ....... .::..:..: AND POLYCARBONATE HOUSING. UNIVERSAL OUNTING .:::.:::............ ...;......... ..I. ........ ......... ......... ......... ........ _......... ......... _... ............................ _............ ......... ......... ................. HARDWARE. _:. ::::........::...... _.. _ ......._ ................ ....... _ ................ -,-.....::. -.WHITE ..M.... .:... :.:. .. SURE LITE APX SERIES .. . . .::......... CHLORIDE SLU'' PEN 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Nov 2013 Project Info Project Address SECU Date 2/27/2015 Compliance 5200 SOUTHCENTER BLVD For Building Department Use forms do not require a TUKWILA, WA 98188 password to use. Applicant Name: CASE ENGINEERING Instructional and calculaSng cells Applicant Address: 19515 NORTH CREEK PKWAY SUITE 302 BOTHELL, WA Applicant Phone: 425-402-9400 are wite- Project Description 113NewBuilding Q Addition ® Alteration Q Plans Included Lighting Compliance Path Lighting Power Density Calculations 0 Total Building Performance (If Total Building Performance then only LGT-CHKis Lighting Power Allowance 0 Building Area Method 0 Space -By -Space Method Method Selection required to enable LPA forms Interior Lighting System Description Briefly describe lighting system type and features. Additions and Change of Space Use (C101.4.3 & C101.4.4) 13 Addition area or Change of Space Use area complies with all applicable provisions as stand alone project 0 Addition area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions per CI01.4.3 Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) ® 60% or more of luminaires in space replaced Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Retrofit and non -retrofit spaces shall be documented separately using multiple forms. 0 Less than 60% of luminaires in space replaced Provide a separate Space -By -Space Method (LTG-INT-SPACE) Compliance Form for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage table. 0 Lamp and/or ballast replacement within existing luminaires only - existing total interior building wattage not increased ® New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 0 New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. 0 Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. Q No changes are being made to the interior lighting and space use not changed. 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Nov 2013 Project Address SECU Date 2/27/2015 ' Alterations Renovations & Building Additions Lighting g o ® o O O 0 than 60 0 60 0 or ore 0 alone Addition Less / / m Stand Notes: . a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. its and building additions provide S s and gross interior areas in the . For retrofits ace Types b o 9 .p A YP Allowed Lighting t 1 71 comply Maximum A g table. a f a builidng addition w� p y as combined with the overall existing builidng, include all applicable existing Space Types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 60% of existing fixtures will be replaced. provide total existing lighting wattage (prior to retrofit in the space provided in the Maximum Allowed Lighting table. For Building Department Use _ Maximum Allowed Lighting Wattage Location (plan #, room #, or ALL) Space Type* oweGross Watts per ft2 Interior Area in ft2 Watts Allowed (watts/ft2 x area) Office Enclosed 1.11 879 976 Office - Open plan 0.98 9624 9432 Bank/office - Banking activity area 1.38 2615 3609 Food preparation 0.99 1582 1566 Electrical/mechanical 0.95 171 162 Storage 0.63 111 70 Conference/meeting/multipurpose 1.23 998 1228 Atrium** Fitter Height ,:: Ex sttn Li ilttn Enter Exist. Sf,..'a I 9 9 I2V-11etafI t7�splajr AIIo>nrarrce from i.GT IttT UISrt AY ..... * Select Table C405.5.2(2) category from drop down menu. Area Allowed Watts ** For atriums, indicate height. Allowed wattage for first 40 feet is 0.03 Wlft. ht., Total 15980 17042 above 40 feet is 0.02 Wlft. ht. Proposed Lighting Wattage Location (plan #, room #, or ALL) Fixture Description*** Number of Fixtures Watts/ Fixture Watts Proposed C1-RECESSED 2x4 TROFFER 126 64 8064 F1-RECESSED DNLT-1 LAMP 78 36 2808 F2-DECORTIVECFL-1 LAMP 5 1 36 1 180 F3-LOW VOLTAGE MONO POINT PENDANT 3 1 60 180 174-RECESSED LOW VOLTAGE ADJUSTABLE ACCENT I 5 1 75 1 375 Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Wattj 11607 *** include existing to remain lighting fixtures and exempt lighting equipment per notes below. Notes: . 1. Include ALL proposed lighting fixtures. 2. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 3. For proposed WattslFixture use manufacturer's listed maximum input wattage of the fixture not simply the lam wattage) and other criteria p p p 9 ( pY p 9) as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. 4. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 5. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description. 6. If #NA appears in Retail Display cells, information on LTG-INT-DISPLAY is incomplete. Interior Lighting Power Allowance COMPLIES c C C ELECTRICAL SYMBOLS & ABBREVIATIONS LEGEND POWER RECEPTACLES & OUTLETS LIGHT FIXTURES & CONTROLS ABBREVIATIONS IO DUPLEX RECEPTACLE O SURFACE CEILING MOUNTED DOWNLIGHT A (200A) (AFTER A NUMBER) = AMPS 0 DOUBLE DUPLEX RECEPTACLE O RECESSED DOWNLIGHT (ROUND) AF(200AF) (AFTER A NUMBER) = FUSE SIZE IN AMPS F01 RECESSED DOWNLIGHT (SQUARE) AFF ABOVE FINISHED FLOOR f@ DUPLEX GFCI RECEPTACLE C) ! PENDANT MOUNTED FIXTURE OR CHANDELIER AL ALUMINUM I@ DOUBLE DUPLEX GFCI RECEPTACLE ATS AUTOMATIC TRANSFER SWITCH Q SINGLE POINT SOURCE WALL MOUNTED FIXTURE 0 DOUBLE DUPLEX RECEPTACLE MOUNTED IN CEILING BKR BREAKER ® SURFACE MOUNTED LINEAR FIXTURE C CONDUIT - M DUPLEX RECEPTACLE MOUNTED +4" TO CENTER OF DEVICE ABOVE COUNTER OR TOP OF BACKSPLASH, WHEN ® RECESSED LINEAR FIXTURE CKT CIRCUIT PRESENT (U.O.N.). COORDINATE EXACT LOCATION WITH © PENDANT MOUNTED LINEAR FIXTURE CL CENTERLINE MILLWORK DETAILS PRIOR TO ROUGH -IN. PENDANT MOUNTED LINEAR WALLWASHER CLG CEILING 10 DOUBLE DUPLEX RECEPTACLE MOUNTED +4" TO CENTER OF - DEVICE ABOVE COUNTER OR TOP OF BACKSPLASH, WHEN =__a LINEAR UNDERCOUNTER FIXTURE C.O. CONDUIT ONLY PRESENT (U.O.N.) COORDINATE EXACT LOCATION WITH MILLWORK --o LINEAR LED COVE, TRACK OR TAPE LIGHT (LENGTH AS CU COPPER DETAILS PRIOR TO ROUGH -IN. i D SHOWN ON PLAN, TRANSFORMER(S) SHOWN AS DIA DIAMETER � DUPLEX GFCI RECEPTACLE MOUNTED +4" TO CENTER OF REQUIRED) DISC DISCONNECT DEVICE ABOVE COUNTER OR BACKSPLASH, WHEN PRESENT -V--Z❑ TRACK LIGHT (LENGTH AS SHOWN ON PLAN) (U.O.N.) COORDINATE EXACT LOCATION WITH MILLWORK DISP DISPENSER DETAILS PRIOR TO ROUGH -IN. 0 RECESSED WALLWASHER DF DRINKING FOUNTAIN 0 DOUBLE DUPLEX GFCI RECEPTACLE MOUNTED +4" TO CENTER OF ® RECESSED EMERGENCY EGRESS 2'x4' FIXTURE DW DISHWASHER DEVICE ABOVE COUNTER OR TOP OF BACKSPLASH, WHEN PRESENT ECB ENCLOSED CIRCUIT BREAKER (U.O.N.) COORDINATE EXACT LOCATION WITH MILLWORK DETAILS ® SURFACE LINEAR EMERGENCY EGRESS FIXTURE (E) EXISTING (USED AS SYMBOL DESIGNATION) PRIOR TO ROUGH -IN. ❑® �o RECESSED EMERGENCY EGRESS DOWNLIGHT EMT ELECTRICAL METALLIC TUBING 1A SWITCHED (SPLIT) DUPLEX RECEPTACLE El 0 SURFACE EMERGENCY EGRESS DOWNLIGHT EXTG EXISTING (USED AS ABBREVIATION IN TEXT) 0 DOUBLE DUPLEX RECEPTACLE WITH 1/2 SWITCHED FLR FLOOR GM MOUNTED EXIT SIGN * GFCI RECEPTACLE WITH WEATHERPROOF WHILE -IN -USE COVER WALL MOUNTED EXIT SIGN FAAP FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL i® SPECIAL PURPOSE RECEPTACLE ® QM DIRECTIONAL EXIT SIGN (ARROWS INDICATE ONE OR TWO SIDES FSD FIRE SMOKE DAMPER SINGLE AND DIRECTION INDICATED) OJ JUNCTION BOX WITH BLANK COVER FUT FUTURE io FURNITURE SYSTEM POWER FEED. MAKE FINAL CONNECTION NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH, MOUNTING & EMERGENCY GEN GENERATOR EGRESS INFORMATION ONLY. REFER TO FIXTURE DESIGNATIONS & LIGHTING TO FURNITURE SYSTEM FLEX CONDUIT (PROVIDED BY OTHERS). FIXTURE SCHEDULE FOR LAMP TYPE & OTHER FIXTURE SPECIFICS. GFCI GROUND FAULT CIRCUIT INTERRUPTER VERIFY REQUIREMENTS. GND GROUND TELE/COMMUNICATIONS SYSTEM DEVICES LIGHTING CONTROLS HTR HEATER ® SINGLE POLE LIGHT SWITCH HWT HOT WATER TANK . TELEPHONE s (LOWER CASE SUBSCRIPT DEFINES LIGHTS THAT ARE TO BE HOA HAND -OFF -AUTO W WALL MOUNTED TELEPHONE (VERIFY MOUNTING HEIGHT) SWITCHED -MATCH WITH LETTERS AT FIXTURE) kCMIL THOUSANDS OF CIRCULAR MILS ® SINGLE GANG TELEPHONE/DATA OPENING. PROVIDE 2-GANG- S3 THREE POLE LIGHT SWITCH KVA 1000 VOLT AMPERES CJUNCTION BOX WITH SINGLE -GANG MUD RING & 3/4-C.O. S DIMMER SWITCH KW 1000 WATTS TO ACCESSIBLE CEILING SPACE. S OCCUPANCY SENSOR LIGHT SWITCH (NUMBER DEFINES RELAY LCP LIGHTING CONTROL PANEL TELEPHONE TERMINAL BOAR - /4 FlR R NUMBER IN LIGHTING CONTROL PANEL -SEE SCHEDULE) LT LIGHT PLYWOOD, 8' HIGH x LENGTH SHOWN ON PLAN S VACANCY SENSOR LIGHT SWITCH LTS(LTG) LIGHTS (LIGHTING) I@ JUNCTION BOX & CONDUIT TO ACCESSIBLE CEILING SPACE S? LIGHT SWITCH WiTH PILOT LIGHT LV LOW VOLTAGE . FOR FURNITURE SYSTEM TELE/DATA CONNECTIONS. PROVIDE CONDUIT REQUIRED FOR QUANTITY OF DATA CABLES. VERIFY S K KEYED SWITCH MCB MAIN CIRCUIT BREAKER QUANTITY OF DATA CABLES WITH OWNER PRIOR TO ROUGH -IN. S LV = LOW VOLTAGE, b = AREA TO BE CONTROLLED BY PHOTOCELL MECH MECHANICAL AV AUDIO/VISUAL OUTLET b R1 R# =RELAY IN LIGHTING CONTROL PANEL MLO MAIN LUGS ONLY S# =SENSOR ZONE N3R NEMA 3R SERVICE GEAR - AS SHOWN ON PLANS Q CEILING MOUNTED VACANCY SENSOR NIC NOT IN CONTRACT CIRCUIT BREAKER PANELBOARD os CEILING MOUNTED OCCUPANCY SENSOR OC ON CENTER G LOAD CENTER oS WALL MOUNTED OCCUPANCY SENSOR OH OVERHEAD G LIGHTING CONTROL PANEL PHOTOCELL LIGHT SENSOR OS OCCUPANCY SENSOR o TERMINAL CABINET PC PHOTOCELL ® SWITCHBOARD OR MOTOR CONTROL CENTER, SIZE PNL PANELBOARD AS SHOWN ON PLANS NOTES AND MISCELLANEOUS SYMBOLS REC RECEPTACLE(S) El DRY TYPE TRANSFORMER (SEE NOTES & RISER 1��> FLAGNOTE - IDENTIFIES A SPECIFIC ITEM ON A DRAWING. REF REFRIGERATOR DIAGRAM FOR SIZE) COORESPONDS TO A SCHEDULE IN THE ELECTRICAL SET THAT (R) RELOCATED EXISTING EXPLAINS DETAILS OR FEATURES OF THAT ITEM. CONDUITS AND CIRCUITING RQMTS REQUIREMENTS - FF 3 - FINES MECHANICAL AND MECHANICAL FLAG DE HANICAL EQUIPMENT SCL SEATTL E CiTY LIGHT WIRING LOCATED IN CEILING OR WALL DESIGNATIONS IN PLANS AND COORESPONDS TO DES MECHANICAL _ _ _ _ WIRING CONCEALED UNDER FLOOR OR UNDERGROUND SCHEDULES. COORESPONDS MECHANICAL CONNECTION SCHEDULE SPD SURGE PROTECTIVE DEVICE IN THE ELECTRICAL SET. SQ SQUARE an CONDUIT HOME -RUN IT INDICATE WIRES -FF-HIFN U TE W ES SLASHES ACROSS COND NUMBER OF- i'- 200 EQUIPMENT FLAG - DEFINES SPECIAL IE: COOKING EQUIPMENT SW SWITCH _ _ = WITHIN SHORT HOT, LONG NEUTRAL ON A PLAN AND COORESPONDS TO DESIGNATIONS IN AN TBD TO BE DETERMINED EQUIPMENT SCHEDULE IN THE ELECTRICAL SET. TTB BOARD TELEPHONE TERMINAL B ---- a ISOLATED GROUND WIRE {� GROUND WIRE 1;1 _ REVISION CLOUD AND FLAG CLOUD SURROUNDS INFORMATION TYP TYPICAL THAT HAS BEEN REVISED. FLAG IDENTIFIES THE REVISION IN UC UNDER COUNTER o CONDUIT IUHNS ANU CHANGES ELEVATION AT [HIS POINT WHICH IHL CHANGES WERE MADE. CONDUIT STUB -UP UG UNDERGROUND 3O DETAIL NUMBER - APPEARS IN FRONT OF A TITLE ON DRAWINGS. UL UNDERWRITER'S LABORATORY —4 �-- CONDUIT BREAK -3 CONDUIT CONTINUES ELSEWHEREON PLAN NOTED ( ) 3 _ SYMBOL CROSS REFE IN IDENTIFICATIONS REFERENCES INFORMATION U.O.N.UNLESS O.N. U OTHERWISE NOTED El.l e ONE AREA WITH SHEET B A DETAIL TOP AND (BOTTOM IN ( UTIL UTILITY EQUIPMENT CONNECTIONS & CONTROLS ANOTHER IN THE ELECTRICAL SET. VA VOLT AMPERES ® EQUIPMENT CONNECTION NOTE: ALL FIXTURES AND EQUIPMENT SHOWN ON PLANS IN STANDARD VS VACANCY SENSOR . (HEAVY) LINE WEIGHT ARE NEW OR RELOCATED WORK. FIXTURES AND i® WALL MOUNTED EQUIPMENT CONNECTION EQUIPMENT SHOWN IN LIGHT LINE WEIGHT WITH (E) NEXT TO THEM W WATTS MOTOR CONNECTION INDICATE EXISTING TO REMAIN. SYMBOLS SHOWN AS DASHED INDICATE ITEMS WAP WIRELESS ACCESS POINT TO BE REMOVED OR DEMOLISHED. SUNLESS NOT 1 E THIS APPLIE ED OTHERW S WC WATER COOLER 4 FAN CONNECTION ON PLANS. W/o WITHOUT D DISCONNECT SWITCH WP WEATHERPROOF I� FUSED DISCONNECT SWITCH XFMR TRANSFORME ---- - - . _ ® MAGNETIC MOTOR STARTER REVIEWED FOR ED COMBINATION STARTER AND DISCONNECT COMPLIANCE WITH i� ENCLOSED CIRCUIT BREAKER NFPA ?Q - NEC . 'I HAND/OFF/AUTO SWITCH - 2 8 2015 •• START —STOP PUSHBUTTON SWITCH ` 4, [7 PUSHBUTTON SWITCH City of -Tukwila' SM MOTOR RATED SWITCH BUILDING DIVISION EN ERA N - AL SHEETS. GENERAL NOTE O L SH S PROVIDE AL EQUIPMENT, CONDUIT A CONDUCTORS FOR CIRCUITING AN 1. L EQU AND C ORS 0 G D CONNECTIONS SHOWN ON PLANS. DRAWING INDEX E001 ELECTRICAL LEGEND, LIGHTING SCHEDULES E002 ELECTRICAL SPECIFICATIONS E D101DEMOLITION 1ST FLOOR ELECTRICAL'PLAN ED102 2ND FLOOR ELECTRICAL DEMOLITION PLAN E201 1ST FLOOR POWER/COMMUNICATIONS PLAN E202' 2ND FLOOR POWERICOMMUNICATIONS PLAN E301 1ST FLOOR LIGHTING PLAN E302' 2ND FLOOR LIGHTING PLAN EL401 1 ST FLOOR LIGHTING CALCULATIONS EL402 2ND FLOOR LIGHTING CALCULATIONS E801' RISER DIAGRAM' CALCULATIONS E901 PANEL SCHEDULES F41 0 0 0 o00 co U'l o ti CIS N 00 � m r- co M CD o n C� a N a o N �t N ti M 0 = -� 0 m � C j 0 ca � .0 = COO 0 0 v 0 o a> o N00 CO a, N N > > 2 fN W h >' �2 d afO a v - o C 2(n U '> ,cam° z W C:, r o co o cD �n o — LU z 0: CD Z w ¢ w 0 0 0 fn C 0) ^� W a) a) 4-i CU . creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS e - 1-1 CASE 0 ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Permitwo. G V 10 ♦ L/�1 Plan review oval is subject aW b ect to er 1 s an d omissions. Ss^l0 ns Approval of canstructia theocum s snot authorize 'OIa violation on Of tl �Y opt 8 Or finance. Rec ei opt 1 approved Field d n P c s is acknowledged: CRY Of Tukwila BU ILDING DIVISION ISSUE/REVISION 03/06/2015 i PERMIT ISSUE -- - --- ` - - _ _-_ -_ _ _ _ 04/10/2015 "__ - BID ISSUE 05/18/2015 1 PERMIT RESUBMITTAL REVISIONS - -' No changes shall be made to th, ,,.nnr, of U'Ork without prior •- : ; P r apprc; . � , , Tukwila Building - ��; r t31vr ,-. NO TE. ' TE. R8V1310riS d'JiII - re ..., and and quire a ne . r _ , , ,�.- n - t;l u Y de additional ' dl tI on al plan an r.-:-.• E P ATl fir- r11,MIT3 IE CUIRFD FOR 111e6hanical Electrical Plumbing Gas Piping i Cs of Tukwila ILi't' _.',P.PIVISION REVISIO'Nk' NO.1- RECEIVED CITY OF TUKWILA MAY 1 9 2015 PERMIT CENTER PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6.2015 -Sk1EET TITLE 'RICAL LEGEND, NG SCHEDULES SHEET NO. E001 © 2015 Cole+Russell Architects, Inc. OB- - - - - ----------------- OC ---------------------- ------ ------ OD a � U (/Q z z - Q U ~U z W O U= F- U zOf Oa LU � J Q J U) XU) oof Z W W J �0 X W O O z�_ Z W W U) jz 0 00 O I- � U W J I- X W W W W W H ZZ) 0 Z F=- F 0 wW �a =a U W IfX Q o. J W D_ � U W 2 J WO 0� r~ � U W 0 W O a0- oa d U W > U U5 W U W W 0z a Q= o F F M U W 0 W 0 2 F- X O 0 R a. N W0 xw �W rn w � Z = T W K v 20 0 p LL U W p Oa W 00 H U U ~ = W O m ii 1 3 ' ` 5 7 08 i i NORTH 1 ST FLOOR POWER/COMMUNICATIONS PLAN IV SCALE: 1 /8" = 1'-0" ------------ - --- __0B ----------------- ------- ------0 FLAG NOTES VERIFY EXACT LOCATION OF POKE—THRU WITH ARCHITECT PRIOR TO ROUGH —IN. VERIFY ELECTRICAL REQUIREMENTS WITH FURNITURE/EQUIPMENT VENDOR. R�> OUTLETS FOR TV'S. COORDINATE LOCATIONS WITH MILLWORK DETAILS. 13 > VERIFY MOUNTING HEIGHT. PRIOR TO ROUGH —IN. R�:> MOUNT RECEPTACLES HORIZONTALLY IN BACKSPASH PER ARCHITECTURAL ELEVATIONS. VERIFY EXACT LOCATION OUTLETS WITH ARCHITECT PRIOR TO ROUGH —IN. [�>WATER HEATER MOUNTED IN CABINETRY — REFER TO MECHANICAL DRAWINGS. GENERAL NOTES 1. OUTLETS SHOWN WITH LIGHT LINEWEIGHT ARE EXISTING TO REMAIN. MAINTAIN CIRCUIT & ACCURACY MARK ON AS—BUILTS. REVIEWED FOR COMPLIANCE WITH NFPA 70 P NEC tA, 23 2015 City ofTukwila BUILDING DIVISION � s t 190 h CO�M R O 0 n N - M � O in m rn o c0�7 l N a CD rn NO O V- N ti Gp = co x O t— O O W N U 0 LOCD c O O CD 0 o co N .a. N N N � N � (6 N 3 � (O ^ C O` C/% tj � Z O 1D O CD O CM O - CD .--� 1` O H W Z It(n J Z Uj Q W M 4 4 creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUE/REVISION 03/06/201, PERMIT ISSUI 04/10/20t BID ISSUI 05/18/20t 01 PERMIT RESUBMITTAI RECEIVED CITY OF TUKWILA �%Y 19 2015 PERMIT CENTER PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6.2015 SHEET TITLE 1ST FLOOR POWER/ COMMUNICATIONS PLAN SHEET NO. E20 1 © 2015 Cole+Russell Architects, Inc. ( B--------- ------ ------ o- ----------------- �U coZ Z ZL) ZU O W U= ~U Z� 0¢ � J �� m CO o� Z+ —w W J 20 HU W LL O O Z� - Z Z W W Z j0 UU 0 F �U W J ~X W W W F-F- W H Zo U= z F- UW W� F- ¢ =W U W <IL ¢ LL J W W m J 0 Cr U0 LL LL O � U W0 W 0 a0- 00 av wLL >w �a �m J W h- 2 a zQ N ¢ = N ~ ~ M U� W r m0 0 a. X N W 0 vi S LL Cn W Z � T W �[) Z>0 LL W U W oa W W op U U O 2 W J rm a 2 ��A T r� 6 ------------------------------- -------------------- -----------------------------A C VERIFY EXACT LOCATION OF POKE—THRU WITH ARCHITECT PRIOR TO ROUGH —IN. VERIFY ELECTRICAL REQUIREMENTS WITH FURNITURE/EQUIPMENT VENDOR. 2� COORDINATE OUTLET LOCATIONS WITH INTERIOR DESIGNER. 13 VERIFY MOUNTING HEIGHT. PRIOR TO ROUGH —IN. 4� MOUNT RECEPTACLES HORIZONTALLY IN BACKSPLASH PER ARCHITECTURAL ELEVATIONS. VERIFY EXACT LOCATION OF OUTLETS WITH ARCHITECT PRIOR TO ROUGH —IN. 5� WATER HEATER MOUNTED IN CABINETRY — REFER TO MECHANICAL DRAWINGS. PROVIDE POWER & DATA CONNECTIONS TO CONFERENCE ROOM TABLE. COORDINATE REQUIREMENTS WITH TABLE SPECIFICATIONS. GENERAL NOTES 1. OUTLETS SHOWN WITH LIGHT LINEWEIGHT ARE EXISTING TO REMAIN. MAINTAIN CIRCUIT & ACCURACY MARK ON AS—BUILTS. REVIEWED FOR COMPLIANCE WITH NFPA70-NEC 2 8 2015 City of -Tukwila BUILDING DIVISIO a O U"> p N CD O r. 'ri N C C6 CSj CD Ch W CD O d P07 d N d D. O O 'a7 p O � H O m j CO C > U U C CU CU ID v p C CDa> CD N N N N N CU 47 -� ? U) j 3: co fn -0 a C O C O` ro U Z Cn O ti O CD CD Co CD CD Co a— I'_ U'� creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUE/REVISION 03/06/2015 PERMIT ISSUE 04/10/2015 BID ISSUE 05/18/2015 Al PERMIT RESUBMITTAL RECEIVED CITY OF TUKWILA MAY 19 2015 PERMIT CENTER PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6.2015 SHEET TITLE 2ND FLOOR POWER/ COMMUNICATIONS PLAN SHEET NO. © 2015 Cole+Russell Architects, Inc. Al) CB � -------_- OC- ------- ----------- ----- - OD — ¢ � U U Z Z - Q� ZU O W U= ~U Z 0 .Q J J 0U ofr z + WLU 20 1-0 0� LL 00 z ,- z Z W W U z 0 UU OH DU W � =a Erx Er W W W W zn z H co ~a =W U� <LL ¢Cn J W 5 �U W mJ LL0 0 oLL �U � W W LL0 0cr crLL LLv LL >0 �W �a J V% U W W H 2 0z a ¢ = u? U 0 W W 0 F= X 0 O LLX N W 0 L fn W U _ W O v li U W p 00 a W U)0 0 S W J F- In a REFER TO I REFER TO PANEL PA5 PANEL PA4 PANEL PA1 PANEL PA4 T T T T NORTH FLOOR PLAN e SCALE: 1/8" = 1'-0" IV -------------- --- =0 -_----_--o ------------------- ---------- t� REVIEWED .FORD COMPLIANCE WITH NFPA 70 - NEC M-4 2 8 2015 City of TUIWIa BUILDING DIVISION m. CD o N W O m C J C5 M a a IN o o pp _ co x rn O �— U m aS C m CD U 0 U 0 o a; CD N � CO fi CV N N ..r _CL) 7 W N N y y � co d C '0 cn Z CO CDf` O Co O Cp In CDCo r- U'3 creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS CASE --=_ ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUE/REVISION 03/06/201 PERMIT ISSU 04/10/201 BID ISSU 05/18/201 A PERMIT RESUBMITTA RECEIVED CITY OF TUKWILA tAY 19 2015 PERMIT CENTER PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 90051 ISSUE DATE MARCH 6.201 SHEET TITLE 1ST FLOOR LIGHTING PLAN SHEET NO. E301 © 2015 Cole+Russell Architects, Inc. 0"' — ODD- -------------------------- - - - -- Q � U Z_ Z Q U ~U Z w 0 U �= U Z o Q LLI � J U) o X Z+ - W W J 20 I- U 2' W 00 Z F- F- Z Z W wm Z 0 U U OF 0U W j =a rx Of WW wr Z Z) 0 z �o Uw W tr I- Q =W UW Qa 0 J w Q� + U W 2 0 U of ' w of U (if �� W0 a- Of � a av wLL > U W �a J � U W W F=-- a z Q M ¢_ F F- Cl) U W 0 W 0 S N O 0 d LL. N W 0 ui = LL H 0 9 f- W U Z T W It 20 :3O LL U W p 0 a W 00 U U 0 2 W J rm a --------------- ------------- g � 8 NORTH 2ND FLOOR LIGHTING PLAN SCALE: 1 /8" = 1'-0" IV GENERAL NOTES 1, CIRCUIT NUMBERS SHOWN REFER TO PANEL F, UNLESS OTHERWISE NOTED. REVIEWED -FOR COMPLIANCE WITH NFPA70 - NEC �.kj 2.8 2015 City ®#TuWla BUILDING DIVISION EL�s-04o6 a Q C> 10 O CD W N W W O C' W M o a C> N to ON O u= N a0 O W Q C C �ca 'V tC U 0 � co v o 0 o m o W co N N N N m N En f/J +.+ �+ > m a o Cn cg '3 Z rmn O O W O W W O W .- t- O creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS -r= CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUE/REVISION 03/06/201 PERMIT ISSUE 04/10/201; BID ISSUE 05/18/201; 01 PERMIT RESUBMITTAL RECEIVED CITY OF TUKWILA t4AY 19 2015 PERMIT CENTER PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6.2015 2ND FLOOR LIGHTING PLAN SHEET NO. E302 © 2015 Cole+Russell Architects, Inc. CD-------------------- - --------- ---- - -- - ------------------- ------ OD - Q � U (n z z - aF- U z Z W 0 U= �- U Z W Q J 0 U o W Z+ — W W J �0 W LL 00 Z �- H Z Z W WZ U O F 0 U W J �WMw W W F-F- w�- zD O Z F=- 1-o U W wIr EL �a =W U W Elf °• rn J W U� Z_ X U + — W ? J > O0 Of O LL oLL f �U � W W- am OM of (L_ w I'- >U �w �a J U) LU W H 2 a z Q V) Q 2 v H H 02 F- nr O o n. W ry W O uS = LL '; F-0 m U) W 2 U)Z :) T W Of v O LL 0 U W W 00 o F O U U = W J r- m a ) r) tr4 j r61 PANEL PA1 PANEL PA4 T T REFER TO I REFER TO PANEL PA5 PANEL PA4 1 ST FLOOR EMERGENCY SCALE: 1/8" = 1'-0" O. ■ EGRESS CALCULATIONe IV Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min BANKING RM EMERGENCY EGRESS Illuminance Fc 3.85 6.1 1.3 2.96 4.69 BREAK RM EMERGENCY EGRESS Illuminance Fc 12.41 23.9 2.1 5.91 11.38 LENDING EMERGENCY EGRESS Floor Illuminance Fc 16.94 26.3 4.1 4.13 6.41 OPEN OFFICE EMERGENCY EGRESS Illuminance Fc 13.39 26.4 1.1 12.17 24.00 _:� ------ - --------- ------------- - ----------- ---- OB �o OD) REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC I j,y 2 8 2015 City of.Tukwila BUILDING DIVISION K-a ON M T- " co CR Q co N O O ti CM N aND M tD U'3 (rI O O '=' a N co O O o o O co ~ Q c N C � •U C � N U O S o co 0 o aj o CO N N h N N N � a � > t6 � 3 N d o C $ > U, z v� o r- o co o co LO o (0 r.- Ln creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUE/REVISION 03/06/201 PERMIT ISSUE 04/10/201 r. BID ISSUE 05/18/2015 01 PERMIT RESUBMITTAL RECEll ` E-L0 CITY OF TUKWILA MAY 19 2015 PERMIT CENTER PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6,2015 SHEET TITLE 1ST FLOOR EMERGENCY EGRESS CALCULATION 0B— 101, --- — — r U)Z Z- �F- Z0 Z U OW U ~U ZW � J J co co �co 0Z) LL zw �0 Ctf LL 00 Z�- �Z Z W W (0 Z �o U O 1- O U W J =a X W W W W H ZZ) .0 U= Z F U W F- =a U W q Qa J W U� D + U J 00 of U � W W ' a� Wa av W LL > U F0W :a J � X 2 W �- a z¢ m Q = N U 0 W W 0 H � O o LL of N W 0 L = LL �W (A W Z W T WO a �O U- U W p oa W 00 F U) U 0 = W J �m a T 2 T ,! TI ;� 8 T! 2ND FLOOR EMERGENCY EGRESS CALCULATIO SCALE: 1/8" = 1'-0" Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min BOARD RM EMERGENCY EGRESS Illuminance Fc 4.13 8.7 1.1 3.75 7.91 OPEN OFFICE EMERGENCY EGRESS Illuminance Fc 15.47 34.8 2.3 6.73 15.13 REVIEWED -;FOR COMPLIANCE WITH NFPA 70 - NEC y2 8 2015 Cify of-T!!tkWila BUILDINr ntvlleinm 5 r.- ov�"' �47' M-1 � S, ii, t v W C CD co N m LM O ti �rj N C M CD " cD �C;m11 0 d M d N a n o N �t t? p � N �W O o F co C > U 0 co v a o CO CO N N N N G) T co j CnCUC o C ,0°r, z o I— o M o c2 LO CDco ti U'3 CD CU creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS -�_ CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUE/REVISION 03/06/201, PERMIT ISSUI 04/10/201 BID ISSUI 05/18/201 Al PERMIT RESUBMITTAI RECEIVED CITY OF TUKWILA MAY 19 2015 PERMIT CENTER PROJECT TITLE SECU TENANT IMPROVEMENT l 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6.2015 SHEET TITLE 2ND FLOOR EMERGENCY EGRESS PLAN SHEET NO. © 2015 Cole+Russell Architects, Inc. Q � U U)z z- F- U 0 OW U= ~U z� Oa J J 0U oZ) LL � ZW W J x0 F- U Of LL 00 zF- �-z z W WU) �z O UU OH 00 W , F- X OfW W W �F- W �- zD 0 zF= �� �o U W W Of H Q =W U W Qa U) J W 5 V� W= J U O 0 LL OF U Q: WU LLQ- oa � U a_ wLL >U � W 0a J � UW W F=- oz LL z Q o ¢_ ? F- m ir UW � W 02 F- O o LLDf N WO 2 LL F- C N tU W U W 20 v U W p O d W 00 F- m U = W 0. F-m a EXISTING RISER DIAGRAM_ NOT TO SCALE t SHORT CIRCUIT CALCULATIONS CIRCUIT DEFINITION CONDUCTOR CIRCUIT IMPEDANCE AVAILABLE MINIMUM DESCRIPTION CONDUIT # IN OHMS/MFT OHMS FAULT PANEL LENGTH MAIL SIZE PARALLEL R. X R X Z CURRENT RATING AVAILABLE FAULT CURRENT @ SCL 300 kVA XFMR 0,00000 0.00216 0.00216 55,560 FEEDER TO 1200A BUSSED GUTTE 145 N 500 kCMIL CU 3 0.027 0.039 0.00131 0.00189 0.00229 (AIC SHOWN AT END OF FEEDER) 0.00131 0.00404 0.00425 28,234 FEEDER TO PANEL PD 15 M 250 kCMIL AL 2 0.086 0.052 0,00065 0.00039 0:00075 (AIC SHOWN AT END OF FEEDER) 0.00195 0.00443 0.00484 24,770 FEEDER TO PANEL. PA1 DISC 5 M 250 kCMIL AL. 1 0.086 0.052 0.00043 0.00026 0.00050 (AIC SHOWN AT END OF FEEDER) 0.00238 0.00469 0.00526 22,798 FEEDER TO PANEL PA1 80 M 3/0 CU 1 0.079 0.052 0.00632 0.00416 0.00757 (AIC SHOWN AT END OF FEEDER) 0.00870 0.00885 0.01241 9,667 FEEDER TO PANEL PA4 95 M 6 CU 1 0.490 0.064 0.04655 0.00608 0Q4695. (AIC SHOWN AT END OF FEEDER) 0.05525 0.01493 0.05723 2,097 FEEDER TO PANEL PA5 50 M 250 kCMIL AL 1 0.086 0.052 0.00430 0.00260 0.00502 (AIC SHOWN AT END OF FEEDER) 0.00625 0.00703 0.00941 12,752 FEEDER TO PANEL PA6 115 M 1 AL 1 0.250 0.057 0.02875 0.00656 0.02949 (AIC SHOWN AT END OF FEEDER) 0.03500 0.01359 0-03755 3,196 FEEDER TO PANEL B DISC 5 M 310 Cu 1 0.079 0.052 0.00040 0,00026 0.00047 (AIC SHOWN AT END OF FEEDER) 0.00170 0.00430 0.00463 25,927 FEEDER TO PANEL 90 M 3/0 CU 1 0.079 0.052 0.00711 0.00468 0.00851 (AIC SHOWN AT END OF FEEDER) 0.00881 0.00898 0.01258 9,536 FEEDER TO PANEL F 95 M 3 CU 1 0250 '0,059 0.02375 000561 0.02440 (AIC SHOWN AT END OF FEEDER) 0.03256 0.01459 0.03568 3,363 NOTES TO CALCULATIONS: 1. CALCULATIONS ARE BASED ON OHMIC METHOD, 120 VOLTS LINE TO GROUND FAULT. 2. CONDUCTOR IMPEDANCE IS BASED ON NATIONAL ELECTRICAL CODE TABLE 9. 3_ CONDUIT MATERIAL: M=MAG, N=NON-MAG x-4-32,5661 AVAILABLE FAULT CURRENT (IN AMPS) LOAD SUMMARY 1200 AMP BUSSED CUTTER 480Y/277V, 3-PHASE, 4-WIRE CONNECTED DEMAND DEMAND LOAD DESCRIPTION LOAD -WA FACTOR kVA AMPS EESTING LOAD MAX DEMAND PER SCL METER 100.6 1.25 125.8 349 (95.6 kW @ 0,95 PF) ADDITIONAL LOAD (PANEL PA4): RECEPTACLES - GENERAL USE** 1.8 1.8 5 HEATING 0.0 1.00 0.0 0 MOTORS 0.0 1.00 0.0 0 LIGHTING 1.8 1.25 2.3 6 KITCHEN 0.0 0-65 0.0 0 OTHER 3.9 1.00 3.9 11 ADDITIONAL LOAD (PANEL PA5): RECEPTACLES - GENERAL USE** 6.4 6.4 18 HEATING 31.4 1.00 31.4 87 MOTORS 0.0 1.00 0.0 0 LIGHTING 2.7 1.25 3.,4 9 KITCHEN 0.0 0.65 0..0', 0 OTHER 28.9 1.00 28.9 80 ADDITIONAL LOAD (PANEL F): RECEPTACLES - GENERAL USE** 6.7 6.7 19 HEATING 0.0 1.00 0.0 0 MOTORS 0.1 1.00 0.1 0 LIGHTING 5.5 1.25 6.9 19 KITCHEN 0.0 0.65 0.0 0 OTHER 20.3 1.00 .20.3 56 TOTAL - 1200A BUSSED GUTTER 210.1 237,8 661 @ 208Y1120V 3PH, 4W *50% DEMAND ON GENERAL USE RECEPTACLES OVER 10 kVA **DOES NOT INCLUDE RECEPTACLES FOR SPECIFIC EQUIPMENT s ,� �LO � v aoo_ o 60 N ; 2 O ti C6 N 0 C J � CD (7 W O d M CL N a a 0CD 0 ,N C=) O -Ir N ti ap = W X O 1- (O ca _ N C > N U m C N U 0 v CD CDa� o W 00 N N y N N N 41 N � T � j d 3 f6 Q p d c (9 _ C O` > ,m Z to o r o � o cc rn o 0) ^O W CD U CD CU creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUE/REVISION 03/06/201 PERMIT ISSUI 04/10/201 BID ISSUI 05/18/201 2!2PERMIT RESUBMITTA REVIEWED.FOR COMPLIANCE WITH Nl*PA70,C,NEC . 28 2915 -- -- City ofTukWila BUILDING DIVISION RECEIVED CITY OF TUKWILA I11AY 19 2015 PERMIT CENTER PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6.2015 SHEET TITLE RISER DIAGRAM SHEET NO. E ff 11 ?45'4'0 1 © 2015 Cole+Russell Architects, Inc. it: NEW PANEL: PA6 PROJECT NAME SECU PROJECT #: 15055 LOCATION: IT ROOM 130 FED FROM: PANEL PA5 NOTE CKT NO CIRCUIT NAME CB SIZE LQAD(KVA) PANEL DESCRPTION _61-AMP P R H M L K 0 TOTAL 1 REC- BREAK ROOM 125 A 20 1 0.2 0-5 0.7 PANEL A MPS : 100 3 REC- BREAK ROOM 125 B 20 1 0.4 0A FEEDER AMPS : 100 L - L VOLTS : 208. 5 REC- BREAK ROOM 125 ISLAND C 20 1 1.0 1.0 7 DISHWASHER A 20 1 1.2 1.2 L- NVOLTS 120 9 COFFEE B 20 1 1.5 1.5 PHASE : 3 11 DISPOSAL C 20 1 0.2 0.8 1.0 WIRE : 4 13 ICEMAKER A 20 1 1.1 IA AIC : 1QkA 15 REFRIGERTOR B 20 1 1 1.1 1.1 17 REFRIGERTOR C 20 1 1.1 1.1 M.L.O. X 19 REC - SERVER 130 A 20 1 1.5 1.5 21 REC - SERVER 130 B 20 1 1.5 1.5 MA IN CB 23 REC-SERVERI30 C 20 1 1.5 1.5 FLUSH 25 SPARE A 20 1 SURFACE X 27 SPARE B 20 1 ISO GND 29 SPARE C 20 1 FEED•THRU 31 SPACE A 33 SPACE B 35 SPACE G 37 SPACE: A LOADSUMMARY' 39 SPACE B ( TOTAL, ALL SECTIONS) 41 SPACE C REC KVA : 2>2 2 1 REC-BREAK ROOM 125 A 20 1 06 0.6 4 REC- LOUNGE 126 B .20 1 0.8 0,5 1:3 HEAT KVA 14.6 MOTOR KVA 6 EWH-2 C 50 2 4.2 4.2 8 - A - - 4.2' 4.2 LIGHTING KVA '> 10 EWH-3 B 40 2 3.1 3.1 KITCHEN KVA OTHER KVA 16.9 12 - C _ _ 3.1 31 14 REC - MICROWAVE A 20 1 1.2 1.2 16 REC-MICROWAVE B 20 1 1.2 1.2 PHASEA KVA; : 10.5 18 REC-MICROWAVE C 20 1 1.2 1.2 AMPS : 87-5 20 SPARE A 20 1 PHASE B KVA : 10.1 22 SPARE B 20 1 AMPS : 84-2 24 SPARE C 20 1 PHASE C KVA : 13-1 AMPS: 109.2 26 SPARE A 20 1 28 SPARE, B 20 1 30 SPACE C 32 SPACE A CONNECTEDLOAD 34 SPACE B KVA : 33.7 36 SPACE C AMPS '. 93-5 38 SPACE_ A DEMANDLOAD 40 SPACE B KVA < 333 42 SPACE Ici :AMPS : 93.5'. NOTESIREIViARKS : 1, 2. 3. DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES -TO IOKVA 100% _ 2.2 REMAINING, OVER 10KVA 506/0 = H HEATING 100% _ 14.6 M MOTORS 100% = LM LARGESTMOTOR 125% L LIGHTING 125% _ K KITCHEN 65% _ O' OTHER 100% = 16.9 NEW PANEL: F PROJECT NAME SECU PROJECT #. 15055 LOCATION: IT ROOM 290 FED FROM PANEL B NOTE CKT NO. CIRCUIT NAM E CIS SIZE LOAD (KVA) PANEL DESCRIPTION OFAMP P R H M L K O TOTAL 1: REC COW ERENCE200 A 20 1 1'.Q 1_'0' PANEL AMPS 100 3 REC - CONFERENCE 241 B 20 1 0.6 0.6 FEEDER AM 100 5 REC - OFFICE 240 C __2T 1 O.2 0.3 O.5 L - L VOLTS : 208 7 REG- OFFICE 240 A 20 1 0.9. 0.9 L - NVOLTS : 120 9 REC - OFFICE 240 BI 20 1 0.9 0.9 PHASE'; 3 11 REC - OFFICE 245 C 20 1 0.9 0.9 WRE : 4 13 REC - CONFERENCE 242 A 20 1 0.9 0.9 AIC : I OkA 15 REC - OFFICE 245 B 20 1 0.8 0.8 17 REC-OFFlCE246 C 20 1 0.6 0.6 19 REC - OFFICE 246' A '20 1 0.9 a M.L.O. X 21 REc- orncc 246 0 20 1 0.9 a.a MAIN CB 23 REC - OFFICE 246 C 20 1 0.6 0.6 FLUSH 25 REC - OFFICE 246 A 20 1 0.9 0.9 SURFACE X 27 REC - OFFICE:246 B 20 1 1 1 0.9 0.9 00 GN0 29 REC - OFFICE 246 C 20 1 1.2 1.2' FEED-THRU 31 REC - OFFICE 246 A 2Q 1 0.6 0.6'. 33 REC - OFFICE 246 B 20 1 0.9 0.9 35 LTS - CONFERENCE ROOM C 20 1 1.2 1.2 37 REC-AV RACK A 20 1 0.5 0.5' LOADSUMMARY 39 REC - CONFERENCE ROOM TABLE B 20 1 0A 0.4 ( TOTAL, ALL SECTI ONS ) 41 SPARE C 20 '1 REG KVA : 6.7 2 LTS - SECU 2ND FLOOR A 20 1 1.3 1.3 4 LTS - SECU 2ND FLOOR B 20 1 1 1.3 1.3 HEAT KVA MOTOR KVA : 0.1 6 LTS - SECU 2ND FLOOR C 20 1 1 1.0 1 1.0 8 LTS - SECU 2ND FLOOR A 20 T 0.7 0.7 LIGHTING KVA : 5.5 10 REC- OFFICE 240 B 20 1 0.9 0.9 KITCHEN KVA 12 REC - OFFICE 240 C 20 1 0.9 0.9 OTHER KVA : 20.3. 14 REC - WORKROOM 243 A 20 1 Q:8 0.8 16 REC - OFFICE 240 6 20 1 O.6 0.6. PHASE A KVA : 11.8 AMPS : 98.3 18 REC - MAIL ROOM 244 C 20 1 0.6 0.6 20 REG - SERVER 290 A 20 1 1.5 1.5 PHASE B KVA : 10.5 22 REC - SERVER 290 61 20 1 1:5 1.5 AMPS: 87:5 24 REC-SERVER290 C 20 1 1.5 1.5 PHASECKVA : 1o.3 26 REC-OFFICE240 A 20' 1 0.9 0:9 AMPS : 85.8 28 REC - OFACE245 B 20 1 0.6 0.6 30 REC - OFFICE247 C 20 1 1.2 1.2 32 REC - OFFICE 246 A 20 1 0.9 O.9 CONNECTED LOAD 34 REC - CONFERENCE ROOM B 20 1 0.2 0.2 KVA : 32..6 36 EF-1 C 20 1 0.1 0.1 AMPS:: 90.5 38 SPARE A 20 1 DEMAND LOAD. 40 ISFARE B 20 1 KVA : 34.0 42 ISPARE C 20 1 A MPS : 94.4 NOTES/REMARKS: 1. 2. 3. DEMAND DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 6.7 REMAINING OVER 10KVA 50016 = H' HEATING 100% _ M MOTORS 100% = LM LARGEST MOTOR 125% = 0.1 L LIGHTING 125% 6.9 K KITCHEN 65% _ 0 OTHER 100% = 20.3 Q rn Z Z- QU) ZU OW U= ~U Z O Q � J �W 0U oM Z W W J 2 O H U �LL 00 Z�_ �-Z Z W W CO 0 U U O H Do W f WW W W W W F-- Z=1 0 z� U� 0 W W M H Q =a U W LL. � Qa 0 J a W CO.. I_ Ir U + - W 2 J 00 LL LL oF- U m � W0 IL Er oa- m U IL_ W LL > U W �W J � UW wr 2 0 Z d _ (0� FF UUl 1z W O= W E- LL' 0 N a Wo L F-. W Z) Z> > W W v 20 LL 0 U W W W 0EL- W 0 H U U ~ = W O r- m a NEW PANEL: PA5 PROJECT NAME SECU PROJECT #: 15055 LOCATION: SUPPLIES 105 FED FROM: PANEL PD NOTE CKT NO CIRCUTNAME CB SIZE LOAD(KVA) PANEL'. DESCRIPTION 9 AM P P R H M L K 0 TOTAL 1 REC - OFFICE 103 A 20 .1 0.9 0.9 PANEL AMPS:: 200 3 REC- OFFICE. 103 B 20 1 0.9 0.9 FEEDERA MPS : 200 5 REC - OFFICE. 103 C 20 1 0.9 0.9 L.- L VOLTS :. 208 L - NVOLTS : 120 7 REC- OFFICE 103 A 20 1 0.6 0.6 9 LTS - OFFICE 103 B 20 1 0.8 0.8. PHASE: 3 11 LTS - BANKING C 20 1 1.2 1.2 WIRE : 4 13 LTS - COhFERNECE_ A 20 1 0-7 0.7 AC : 22kA 15 REG - BANKING TV WALL B 20 1 1.0 . 1.0 17 REC- BANKING TV WALL Cl20 111 1;0 1..0 19 REC-BANKING TV WALL A 20 f1 1.0 1.0 RL..O. MAIN CB X 21 REG- OFFICE 103 B 20 1 1.2 1.2 23. REC- OFFICE 10 1, 102 C 20 i1 1.2 1.2. FLUSH 25 REC - CONFERENCE 'ROOM .FLOORBOX A 20 1 0.2 ; 0.2 SURFACE X 27 SPARE B 20. 1 ..._ ISO GND 29 SPARE C 20 1 FEED•THRULj 31 SPACE A 20 1 33 SPACE H -35 SPACE C 37 SPACE A LOADSUVIMARY 39 SPACE B (TOTAL ALL SECTIONS) 41 SPACE G REC KVA : 6.4 2 REC- CONFERENCE 104 A 20 1 0.8 0.8 4 REG - WORKROOM.105 B 20 ' 1 1.0 1.0 HEAT KVA : 31.4 MOTORKVA: 6 REC - KITCHEN 106 C 20 1 1.5 1!5' 8 REC - KITCHEN 106: A 20 1 1:5 1.5 LIGHTING-KVA : 2.7 10 REC- BANKING 100 B 20 1 0.4 0.4 KITCHEN KVA 1.2 REC- BANKING IOGRECEPTION DESK C 20 '1 0-2 0.2 OTHERKVA': 28:9. 14 REC - BANKING 100 FLOOR BOXES A 20 1 0.4 O.4' PHASEA KVA : 25,0 AMPS `: 208.3 16 REC- BANKING 100 ATM S 20: 1 0,5 0.5 1.8 REC - BA NKING 100: ATM C 20 1 1.0 1.0 20 EVVH-1 A 50..2 4.2, 42 PHASEBKVA 20.1 22 - B - - 4.2 4.2' AMPS:: 167.5 24 EWF 1-4 G 50 2 4.2 4.2 PHASE C KVA : 24.3 26: - A - - 4.2 4.2 AMPS':: 202.5 28. SPARE B 20 1 30 SPARE C 20 1 32 SPACE A CONNECTED LOA D 34 SPAN B KVA : 69.4 36 SPACE C AMPS 192.6 38 SUBFEED -PANIELPA6' A 100 3 0.8 4.2 5.5 10,5 DEMANDLOAD 40: - B - - 1.2 3.1 5.8 10.1 KVA:: 70.1 :42 - C - - 0.2 73 5:6 °13.1 AMPS :: 194.5 NOTESIREMARKS : 1, 2. 3. DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 6.4 REMAINING OVER 10KVA 50% _ H HEATING 100% = 31.4 M MOTORS 1.00%, _ LM LARGESTMOTOR 12M,,o = .L _LIGHTING 125% = 3A K KITCHEN 65% - O OTHER 100% = 28.9 EXISTING PANEL: D PROJECT NAME SECU PROJECT#: 15055 LOCATION: 21\11D FLOOR ELECTRICAL ROOM FED FROM. PANELS. NOTE CKT NO CIRCUTNAME CBSIZE LOAD(KVA) PANEL' DESCRIPTION 8 AM P R H M L K 0 TOTAL 1 REC'- DEDICATED A 20 1 0.4 0.4 PANEL A MPS' . 100 3 REC- OFFICES. B 20 1 0.6 O.6' FEEDERAM)PS : 70 5 LTS - OFFICES C 20 1 0.7 0.7 L - L V OLTS : 208 L - N V OLTS : 120 7 LTS - LA NGUAGE DY NAMICS A 20 1 1.1 1.1 9 LTS - OFFICES BI 20 1 0.9 0.9 PHASE : 3 11 LTS - OFFICES Cl20 1 0.8 0.8 WIRE : 4 ML.O. MAIN 00 X FLUSH SURFACE X ISO GND FEED-THRU LOAD SUMMARY (TOTAL, ALL SECTI ON S ) REC KVA : 1.0 2 WA MORTGAGE COMPUTER A 1513 0.8 O.8 4 B - - 0.8 0.8 HEAT KVA MOTOR KVA = 6 C - - 0.8 0.8 8 WA MORTGAGE COMPUTER A 20 2 1.0 1.0 LIGHTING KVA : 3.5 10 B - 1.0 1.0 KITCHEN KVA 12 REC - WA MORTGAGE C 20 1 0.4 0.4 OTHER KVA : 4.8 PHASEA KVA 3.3 A KIPS : 27.5 PHASE B KVA : 3.3 AM'S : 27.5 PHASE C KVA : 2.7 AMPS : 22.5 CONNECTED LOAD KVA : 9.3 AMPS.: 25.8 DEMAND LOAD KVA . 10.2 AMPS : 28.2 NOTESIREMARKS 1. NO NEW WORK -SHOWN FOR REFERENCE ONLY 2. 3. DEMAND I DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 1.0 REMAINING OVER 10KVA 50% = H HEATING 100% M MOTORS 100% = LM LARGEST MOTOR 125% _ L LIGHTING 125% = 4A IC KITCHEN 65% = 0 OTHER: 100% = 4.8 NEW PANEL: PA4 PROJECT NAME SECU PROJECT ##: 15055 LOCATIOR IT ROOM 130 FED FROM: PA NEL PA 1 NOTE CKT NO. CIRCUT NAME CB SIZE LOAD(KVA) PANEL DESCRIPTION 9 AM P P R H M L K O TOTAL 1 REC- OFFICE 110 A 20 1 0.8 0,8 PANEL AMPS : 60 3 REC - OFFICE 110 B 20 1 0.6 0.6 FEEDER AMPS °_ 60' 5 REC - OFFICE 110 C 20 '1 1.2 1.2 L - L VOLTS': 208 L - NVOLTS ` 120 7 REC- OFFICE 110 A 20 1 09 0.9 9 REC- OFFICE 110 B 20 1 0.9 0.9 PHASE : 3 11 REC - OFFICE 110 C 20 1 0.2 0.2 WIRE : 4 13 REC - OFFICE 110 A 20 1 0.6 0.6 AIC : I OkA 15 REC - OFFICE 110 B 20 1 0.3 0.3 17 SPARE C 20 1 19 SPARE A 20 1 ML;O. MAIN CB X 21 SPARE B 20 1 23 SPARE G 20 1 FLUSH 25 SPACE A SURFACE X 27 ISPACE B I I ISO GND FEED-THRU 29 SPACE C LOADSUMM.ARY (TOTAL, ALL SECTIONS) REC KVA : 1.8 2 LTS - SECU 1ST FLOOR A 20 '1 1 1.0 1.0 4 LTS - SECU 1 ST FLOOR B 20 1 0.6 1 0.6 HEAT KVA = MOTOR KVA 6 LTS - SECU 1ST FLOOR C 20 1 0.2 1 0.2 8 SPARE A 2011 LIGHTING KVA : 1-8 10 REC - OFFICE 110 FLOORBOX B 20 1 0.2 0.2 KITCHEN KVA : OTHER KVA : 3.9 12 SPARE G 20 1 14 SPARE A 20 1 16. SPARE B 20' 1 PHASEA KVA ; 3.3 AMPS : 2T5 18 SPARE C '20 1 20 SPARE Aj 20 1 PHASES KVA : 2.6 22 SPARE- B 20 1' AMPS : 21.7 24 SPARE C 20 1 PHASEC.KVA : 1-6 26 SPACE A AMPS : 13.3 28 SPACE B 30 SPACE C CONNECTED LOAD KVA : T5 AMPS : 20.8 DEMAND LOAD KVA : 8.0 AMPS : 22.1 NOTESIREMARKS : 1. 2. 3. DEMAND DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES -TO 10KVA 100% = 1.8 REMAINING OVER'10KVA' 50% = H HEATING 100% = M MOTORS 100%u = LM LA RGEST MOTOR 125%Q = L LIGHTING 125% = 2.3 K KITCHEN 65% _ 0 OTHER 100% = 3.9 EXISTING PANEL: B PROJECT NAME SECU PROJECT # 15055 LOCATION 2ND FLOOR ELECTRICAL ROOM FED FROM 1200A BUSSED GUTTER NOTE CKT NO. CIRCUIT NAME CB SIZE LOAD(KVA) PANEL DESCRIPTION 0 AMP P R H M L K O TOTAL 1 REC-OFFICE A 20 1 1.0 1.0 PANELAMPS : 200 3 REC-OFFICE B 20 1 1.2 1.2 FEEDERAMFS: 200 5 1 REC-OFFICE C 20 1 0.8 &8 L- LVOLTS : 208 L- NVOLTS : 120 7 LTS - WA MORTGAGE A 20 1 1.1 1.1 9 LTS - WA MORTGAGE. B 20 1 0.6 0,6 PHASE : 3 11 LTS - WA MORTGAGE' C 20 1 0.7 0.7 WIRE : 4 13 LTS - WA. MORTGAGE A 20 1 0.9_ _ 0.9 15 LTS - WA MORTGAGE B 20.1 0.4 0.4 17 REC - WA MORTGAGE CE20 1 0.8 0.8 19 REC - WA MORTGAGE A 1 0; 6 0.6 M LO, X 27 rt[C- WA MCRTCACG D 0.6 0.6 MAIN CD 23 REC- WA MORTGAGE C1 1.0 1.0 FLUSH 25 LTS - 230 A 1 Q.8 0.8 SURFACE X 27 LTS - 230 B 20 1 0.7 0.7 ISO GND 29 REC - HA H C 20 Ill 0.4 0.4 FEED-THRU 31 REC - WA MORTGAGE A 20 1 1.0 1.0 33 REC - WA MORTGAGE B 20 1 0.8 0.8 35 REC- SUPPLY ROOM C 20 1 0.4 0A 37 REC- SUPPLY ROOM A 20 1 0.4 0.4 LOADSUMMARY (TOTAL, ALL SECTIONS) 39 REC- TENANT OFFICES B 20 1 1,0 1.0 41 REC - TENANT OFFICES C 20 1 1.2 1.2 REC KVA : 21.7 2 REC - OFFICES A 20 1 0.4 1 0.4 4 REC - OFFICES B 20 1 0.6 0.6 HEAT KVA MOTOR KVA : 3.8 6 REC - INTERNATIONAL SHIP C 20 1 0.8 0.8 8 LTS - RESTROOM A 2O 1 0.5 0.5 LIGHTING KVA : 16.0 10 LTS - OUTDOOR SOFFIT B 20 1 0.9 0.9 KITCHEN KVA 12 LTS - LOBBY C 20 1 0.4 0.4 OTHER KVA : 26.0 14 WATER COOLER A 20 1 0.6 0.6 16 REC - PHONES B 20 1 0.2 0.2 PHASE A KVA : 24.2 18 RESTROOM EXHAUST FANS C 15 1 0.7 0.7 1AMPS : 201.7 PHASES KVA : 21.7 1 20 SUBFEED- PANEL F A 100 3 2.7 2.0 7.1 11.8 22 - B - - 2.0 1.3 7.2 10.5 AMPS : 180.8 24 - C - - 2.0 0.1 2.2 6.0 10.3 PHASE C KVA : 21.6 AMPS : 180.0 26 SPRINKLER COMPRESSOR A 15 3 0.8 0.8 28 - B - - 0.8 0.8 30 - C - - 0.8 0.8 32 REC- OFFICES A 20 1 1.0 1.0 CONNECTED LOAD 34 LTG CONTROL B 20 1 0.1 0.1 KVA : 67.5 36 REC - OPEN OFFICE C 20 1 0.6 0.6 AMPS : 187.4 38 SUBFEED- PANEL D A 70 3 1.1 2.2 3.3 DEMAND LOAD 40 - B - - 0.6+_ 0.9 1.8 3.3 KVA : 65.9 42 - Cl- - 0.4 1.5 Q.8 2.7 AMPS : 182.8 NOTESIREMARKS : 1. PROVIDE NEW BREAKER AS SHOWN. REPLACEEXTG SPARE. RELOCATEC1RCUTS IF REQUIRED. 2. 3. DEMAND DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES -TO IOKVA 100%' = 10.0 REMAININGOVERIOKVA 509% = 5.9 H HEATING 100% _ M MOTORS 100% = 3.0 LM LA RGEST MOTOR 125% = 1.0 L LIGHTING 125% = 20.0 K KITCHEN 65% = 0 OTHER 100% = 26.0 EXISTING PANEL: PA'I PROJECT NAME SECU PROJECT # 15055 LOCATION: 1ST FLOOR ELECTRICAL ROOM FED FROM: PANEL PD NOTECKT NO. CIRCUIT NAME CB SIZE LOAD(KVA) PANEL DESCRIPTION GIAIVF P R H M' L K O TOTAL 1 REC- TTB Al20 1 0.2 0.2 PANEL AMPS : 200 3 COPY MACHINE BI 20 1 1.2 1.2 FEEDER AMPS : 200 L - L V OLTS : 208 L - N VOLTS : 12Q 5 COFFEE C 20 1 1.0 1.0 7 REC- OFFICE A 20 1 0.6 Q:6 9 LTS - CLASSROOM B 20 1 0.5 0.5 PHASE: 3 11 REC-OFFICE C 20 1 0.8 0.8 WIRE 4 13 REC - DOW A 20 1 1.0 1.0 15 REC - DOW B 2011 0 1 0.6 0.6 17 REC- DOW C 20 1 0.6 0.6 19 REC-TA 18 A 20 1 0.8 .0.8 ML.O. MAIN CB X 21 REC - TA 18 B 20 1 1.2 1.2 23 REC -TA18 C 20 1 0.6 0,6 FLUSH 25 REC - PRIVATE OFFICES A 20 1 0.8 0.8 SURFACE X 27 REC -PRIVATE OFFICES B 20 1 0.6 0.6 ISO GND 29 REC -PRIVATE OFFICES C 20 1 0.6 0.6 FEED-THRU 31 REC - PRIVATE OFFICES A 20 1 0.4 0.4 33 REC-PRIVATE OFFICES B 20 1 0.8 0.8 35 REC - PRIVATE OFFICES C 20 1 0.6 0.6 37 FLOAT SWITCH A 20 1 0.1 O.i LOADSUMMARY 39 HEAT - SPRINKLER ROOM B 20 ' 2 1.0 1:0 (TOTAL, ALL SECTIONS) 41 - C - - 1.0 1.0 REC KVA : 18.4 2 REC - OFFICES A 20 1 0.6 .0.6 4 REC- OFFICES B 20 1 0.8 0.8 FEAT KVA ` 26.0 MOTOR KVA : 6 REC- OFFICES C 20 1 0.8 0.8 8 WATER HEATER A 100 3 8.0' 8.0 LIGHTING KVA 10 - B - - &0' 8.0 KITCHEN KVA = 12 -_ C - - 8-0 8.0 OTHER KVA ._' 8.8 14 REC- PRIVATE OFFICES A 20 1 1.2 1.2 PHASEA KVA, : 18:0 AMPS : 150.0 16 REC- PRIVATE OFFICES B 20 1 1:0 1.0 18 REC - PRIVATE OFFICES _ C `20 1 0.6 0.6 20 REC- PRIVATE OFFICES A 20 1 0.6 0.6 PHASE B KVA-: 20.0 AMPS : 166.7 22 REC-DEDICATED B 20 1 0.8 O.8 24 REC - FLOOR PLUGS C 20 1 0.4 0.4 PHASE C KVA : I T 5 26 REC- FLOOR PLUGS A 20 1 0.4 0.4 AMPS : 1453 28 REG - OPEN OFFICE B 20 1 0.9 0.9 30 REC- OPEN OFFICE C 20 '1 0.9 0.9 1 32 SUBFEEI?=PANEL PA4 A 60 3 1.4 1.0 0.9 3:3 CONNECTED LOAD 34 - B - 1-1 0.2 0.6 1 1-8 2.6 KVA : 55.5 36 - C - - 0.2 0.2 12 1.6 AMPS - 154.1' 38 SPARE A 20 '1 DEMAND LOAD 40 SPARE, B 20 1 _ KVA : 51.9 42 SPARE C 20 1 I AMPS : 144.0 NOTESIREMARKS : 1. PROVIDE NEW BREAKERAS'SHOWN. REPLACEEXTG SPARE. RELOCATECIRCUTS IF REQURED. 2. 3. DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES -TO 1OKVA 100% = 10.0 REMAINING OVER 10KVA 50% = 4.2 H HEATING 100% = 26.0 M MOTORS 100% -. LM LARGEST MOTOR 125% = L LIGHTING 125% = 2.9 K KITCHEN 65%Q 0 OTHER 100% = 8.8 NEW PANEL: PI) PROJECT NA ME SECU PROJECT #: 15055 LOCATION: BASEMENT MAIN Ef.ECTRICALROOM FED FROM 1200A BUSSEDGUTTER NOTE CKT NO. CIRCUT NAME CBSIZE LOAD(KVA) PANEL DESCRiPTI(Nd 8 AMi' P R H M L K O TOTAL 1 SUBFEED- PANEL PA1 A 200 31 &0 8_0' 1.0 1.O 18.0 PANELAMPS 400 3 - B = - ;5.2 9.0 1.1 : 4:7 20.0 'FEEDERAMPS : 400 5 - C - - 5.2 9.0 0.2 : 3.1 17.5 1 L - L V OLTS : 208 7 SPACE A- 3 L- N VOLTS : 120 9 - B - - PHASE: 3 11 - C - - WIRE : 4 13 SPACE A - 3 'AIC : 42kA 15 - B - - 17 - C - - M.L.O. MA INCe X FLUSH SURFACE X ISO GND FEED-THRU LOAD SUMMARY ( TOTAL, ALL SE071 ON S } REC KVA : 24.8 2 PANEL PA 5 A 200 31 2.2 12.6 0.7 9.5 25.0 4 - B - - 2.6 T3 0.8 ! 9.4 20A FEAT KVA : 57A MOTOR KVA 6 - C - - 1.6 11.5 1-2 10.0 24.3 8 SPACE A - 3 LIGHTING KVA.- 5.0 10 - B - - KITCHEN KVA : 12 - C - - OTHER KVA : 37.7 14 SPACE A - 3 PHASEA KVA = 43.0 16 - B - - 18 - C - - AMPS : 358.3 PHASE B KVA : 40.1 AMPS : 334:2 PHASE C KVA : 41.8 AMPS : 348.3 CONNECTED LOAD KVA : 124.9 AMPS.: 346.7 DEMAND LOAD KVA : 118.8 AMPS : 329.6 NOTESIREMARKS : 1. 2. 3. DEMAND DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% 10.0 REMAINING OVER 10KVA 50% = 7_-4 H HEATING 100% = 67.4 M MOTORS 100% = LM LARGEST MOTOR 125% _ L LIGHTING 125% _ 6.3 K KITCHEN' 65% _ 0 OTHER 100% = 37.7 CHANGES TO PERMIT SET 1. CIRCUIT LOADS CHANGED PER REVISIONS TO POWER & LIGHTING PLANS n Lo co 0 o m 00 co m � o r- Crj N co C6 co n ;n C'6 rn 8 0 d m ❑. N CN N o N N r W o c Ca > o CJ C3 U v 0 o o N � N N N N y � T � j 3 N m a C O U LO Z fn o r o CO o co m o m r U') 0) U L CU creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUE/REVISION 03/06/201 PERMIT ISSUE 04/10/2011 BID ISSUE 05/18/201 01 PERMIT RESUBMITTAI REVIEWED.FOR COMPLIANCE WITH NFPA 70 - NEC �4412 8 2015 City Of Tu wl BUILDING DIVISION RECEIVED CITY OF TUKWILA SAY 19 2015 PERMIT CENTER PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6.2015 SHEET TITLE PANEL SCHEDULES sa SHEET NO. E901 © 2015 Cole+Russell Architects, Inc. id wz z- a� rU zw 0 U= F U zQ OJ J W o� W FU LL z° 1- z Wz UU of -- cc.) is W W �F- M o z~ (6 WOE F o<. =W it 0. Qrn N J W V)~ U W = O� U� LL o LLL- �W W� aX a. aLL LL >W �a. = a r zZ a Fr o Q N a0 0 =0 ro ca Cn W z LLIo • �O U U W p oa W yU = W J rm a 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Nov 2013 Project Info Project Address SECU Date 2/27/2015 Compliance 5200 SOUTHCENTER BLVD For Building Department Use forms do not ............... ...... .. TUKWILA, WA 98188 require a password to use. Applicant Name: CASE ENGINEERING instructional and calculating cells Applicant Address: 19515 NORTH CREEK PKWAY SUITE 302 BOTHELL, WA Applicant Phone: 425-402-9400 are wite- Project Description ❑ New Building ❑ Addition ® Alteration ❑ Plans Included Lighting Compliance Path Lighting Power Density Calculations 0 Total Building Performance (If Total Building Performance then only LGT-CNKis Lighting Power Allowance 0 Building Area Method Space -By -Space Method Method Selection required to enable LPA forms Interior Lighting System Description Briefly describe lighting system type and features. Additions and Change of Space Use (C101.4.3 & C101.4.4) ❑ Addition area or Change of Space Use area complies with all applicable provisions as stand alone project ❑ Additionarea is combined with existing building lighting systems to demonstrate compliance with all applicable provisions per C101.4.3 Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) ® 60% or more of luminaires in space replaced Provide Building Area Method (LTG-iNT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Retrofit and non -retrofit spaces shall be documented separately using multiple forms. ❑ Less than 60% of luminaires in space replaced Provide a separate Space -By -Space Method (LTG-INT-SPACE) Compliance Form for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage table. ❑ Lamp and/or ballast replacement within existing luminaires only -existing total interior building wattage not increased New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.23), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 ❑ New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of fighting controls per C405.13. ❑ Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. ❑ No changes are being made to the interior lighting and space use not changed. 2012 Washinaton State Enerov Code including R2 S R3 over 3 stories and all R1 RAVICpd Kim Project Address SECU Date 2/27/2015 Lighting Alterations, Renovations & Building Additions For Building Department Use 0 Less than 60% 60% or more 0 Stand alone 0 Addition fixtures replaced fixtures replaced bldg. addition combined w/exist Notes: a. Lighting fixtures in a building addition may comply as a stand alone project or they may be combined with the overall existing bldg fighting to demonstrate compliance. Refer to C101.4.3. b. For retrofits and building additions, provide Space Types and gross interior areas in the Maximum Allowed lighting table. If a budidng addition will comply as combined with the overall existing builidng, include all applicable existing Space Types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 60% of existing fixtures will be replaced, provide total existing fighting wattage (prior to retrofit) in the space provided in the Maximum Allowed Lighting table. Maximum Allowed Lighting Wattage Location (plan #, Allowec Gross Interior Watts Allowed room #, or ALL) Space Type* Watts per ff Area in ff (watts/fe x area) Office - Enclosed 1.11 879 976 Office -Open plan 0.98 9624 9432 Bankloffice - Banking activity area 1.38 2 615 3609 Food preparation 0.99 1582 1566 Electricallmechanical 0.95 171 162 Storage 0.63 ill 70 Conference/meeting/multipurpose 1.23 998 1228 Atrium- Enter Height - Existing Lighting:' Enter Exist: Watts: Retail Display Allowance from LGT-INT-DISPLAY Select Table C405.5.2(2) category from drop down menu. Area Allowed Watts " For atriums, indicate Neigh[ Allowed wattage for first 40 feet is 0.03 W/R. ht., Total 15980 1 17042 above 40 feet is 0,02 W11 ht. Proposed Lighting Wattage Location (plan #, room #, or ALL) Fixture Description— Number of Fixtures Watts/ Fixture Warts Proposed CI -RECESSED 2x4TROFFER 124 64 7936 F1-RECESSEDDNLT-1 LAMP 87 36 3132 F2-DECORTIVE CFL-1 LAMP 6 36 216 Retail Display Lighting from LGT=INT-DISPLAY - Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watq 11284 —Include existing to remain lighting fixtures and exempt lighting equipment per notes below. Notes: 1. Include ALL proposed lighting fixtures. 2 For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length ' f i g g, gth of the track (in feet) n addition to the fixture, lamp, and ballast information. 3. For proposed WattslFixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.a 1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices of the transformer. For low voltage track fighting list the transformer rated wattage. 4. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave WattsiFixture blank. 5. Document existing to remain frxtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description. 6. If #NA appears in Retail Display cells, information on LTG-INT-DISPLAY is incomplete. Interior Lighting Power Allowance COMPLIES ELECTRICAL SYMBOLS & ABBREVIATIONS LEGEND NOTE: ALL FIXTURES AND EQUIPMENT SHOWN ON PLANS IN STANDARD NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH, ABBREVIATIONS (HEAVY) LINE WEIGHT ARE NEW OR RELOCATED WORK. FIXTURES AND MOUNTING & EMERGENCY EGRESS INFORMATION ONLY. EQUIPMENT SHOWN IN LIGHT LINE WEIGHT WiTH (E) NEXT TO THEM REFER TO FIXTURE DESIGNATIONS & LIGHTING FIXTURE A (200A) (AFTER A NUMBER) = AMPS INDICATE EXISTING TO REMAIN. SYMBOLS SHOWN AS DASHED INDICATE SCHEDULE FOR LAMP TYPE & OTHER FIXTURE SPECIFICS. AF(200AF ) (AFTER A NUMBER) = FUSE SIZE IN AMPS ITEMS TO BE REMOVED OR DEMOLISHED. THIS APPLIES UNLESS NOTED OTHERWISE ON PLANS. AFF ABOVE FINISHED FLOOR AL ALUMINUM POWER RECEPTACLES & OUTLETS LIGHT FIXTURES & CONTROLS AL AUTOMATIC TRANSFER SWITCH 14D DUPLEX RECEPTACLE O SURFACE CEILING MOUNTED DOWNLIGHT BKR BREAKER DOUBLE DUPLEX RECEPTACLE O RECESSED DOWNLIGHT (ROUND) C CONDUIT k9 DUPLEX GFCI RECEPTACLE 0 RECESSED DOWNLIGHT (SQUARE) CKT CIRCUIT DOUBLE DUPLEX GFCI RECEPTACLE 0 0- PENDANT MOUNTED FIXTURE OR CHANDELIER CL CENTERLINE DOUBLE DUPLEX RECEPTACLE MOUNTED IN CEILING Q Q SINGLE POINT SOURCE WALL MOUNTED FIXTURE CLG CEILING C.O. CONDUIT ONLY k� DUPLEX RECEPTACLE MOUNTED +4"O.C. ABOVE COUNTER ® SURFACE MOUNTED LINEAR FIXTURE OR BACKSPLASH, WHEN PRESENT (U.O.N.) ® RECESSED LINEAR FIXTURE CU COPPER DOUBLE DUPLEX RECEPTACLE MOUNTED +4"O.C. ABOVE © PENDANT MOUNTED LINEAR FIXTURE DIA DIAMETER COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) PENDANT MOUNTED LINEAR WALLWASHER DISC DISCONNECT DISC DISPENSER k® DUPLEX GFCI RECEPTACLE MOUNTED +4"O.C. ABOVE== -=a LINEAR UNDERCOUNTER FIXTURE DF DRINKING FOUNTAIN COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) —o LINEAR LED COVE, TRACK OR TAPE LIGHT (LENGTH AS DW DISHWASHER f� DOUBLE DUPLEX GFCI RECEPTACLE MOUNTED +4"O.C. ABOVE SHOWN ON PLAN, TRANSFORMER(S) SHOWN AS COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) REQUIRED) ECB ENCLOSED CIRCUIT BREAKER -Z-SZp TRACK LIGHT (LENGTH AS SHOWN ON PLAN) (E) EXISTING (USED AS SYMBOL DESIGNATION) t(n SWITCHED (SPLIT) DUPLEX RECEPTACLE EMT ELECTRICAL METALLIC TUBING (� DOUBLE DUPLEX RECEPTACLE WITH 1/2 SWITCHED RECESSED WALLWASHER EXTG EXISTING (USED AS ABBREVIATION IN TEXT) l GFCI RECEPTACLE WITH WEATHERPROOF WHILE -IN -USE COVER ® RECESSED EMERGENCY EGRESS 2'x4' FIXTURE FLR FLOOR WID FAAP FIRE ALARM ANNUNCIATOR PANEL l® SINGLE SPECIAL PURPOSE RECEPTACLE ® SURFACE LINEAR EMERGENCY EGRESS FIXTURE FACP FIRE ALARM CONTROL PANEL ® FIXTURE SPLIT BETWEEN NORMAL AND EMERGENCY EGRESS QJ JUNCTION BOX WITH BLANK COVER WITH UL924 RELAY. DUAL CIRCUITS SHOWN ON PLANS. FSD FIRE SMOKE DAMPER H-3/X-23 FLIT FUTURE TELE/COMMUNICATIONS SYSTEM DEVICES RECESSED EMERGENCY EGRESS DOWNLIGHT GEN GENERATOR ® TELEPHONE 130 SURFACE EMERGENCY EGRESS DOWNLIGHT GFCI GROUND FAULT CIRCUIT INTERRUPTER ®W WALL MOUNTED TELEPHONE (VERIFY MOUNTING HEIGHT) ® UNIVERSAL/CEILING MOUNTED EXIT SIGN GND GROUND ® SINGLE GANG TELEPHONE/DATA OPENING Q1 WALL MOUNTED EXIT SIGN HTR HEATER TTB ®® DIRECTIONAL EXIT SIGN (ARROWS INDICATE ONE OR TWO SIDES HWT HOT WATER TANK TELEPHONE TERMINAL BOARD - 3/4" FIRE RESISTANT AND DIRECTION INDICATED) HOA HAND -OFF -AUTO PLYWOOD, 8' HIGH x LENGTH SHOWN ON PLAN AV LIGHTING CONTROLS kCMIL THOUSANDS OF CIRCULAR MILS AUDIO/VISUAL OUTLET KVA 1000 VOLT AMPERES SERVICE GEAR - AS SHOWN ON PLANS S SINGLE POLE LIGHT SWITCH (LOWER CASE SUBSCRIPT DEFINES LIGHTS THAT ARE TO BE KW 1000 WATTS SWITCHED -MATCH WITH LETTERS AT FIXTURE) LCP LIGHTING CONTROL PANEL CIRCUIT BREAKER PANELBOARD LT LIGHT 6 LOAD CENTER THREE POLE LIGHT SWITCH LTS(LTG) LIGHTS (LIGHTING) G LIGHTING CONTROL PANEL S DIMMER SWITCH LV LOW VOLTAGE I� TERMINAL CABINET S OCCUPANCY SENSOR LIGHT SWITCH (NUMBER DEFINES RELAY NUMBER IN LIGHTING CONTROL PANEL -SEE SCHEDULE) MCB MAIN CIRCUIT BREAKER SWITCHBOARD OR MOTOR CONTROL CENTER, SIZE MECH MECHANICAL AS SHOWN ON PLANS S VACANCY SENSOR LIGHT SWITCH JDRY TYPE TRANSFORMER (SEE NOTES & RISER Sp LIGHT SWITCH WITH PILOT LIGHT MLO MAIN LUGS ONLY DIAGRAM FOR SIZE) SK KEYED SWITCH N3R NEMA 3R S LV =LOW VOLTAGE, b =AREA TO BE CONTROLLED, NIC NOT IN CONTRACT CONDUITS AND CIRCUITING bR1 R# = RELAY IN LIGHTING CONTROL PANEL OC ON CENTER = S# SENSOR ZONE OH OVERHEAD WIRING LOCATED IN CEILING OR WALL - — — - WIRING CONCEALED UNDER FLOOR OR UNDERGROUND vs CEILING MOUNTED.VACANCY SENSOR OS OCCUPANCY SENSOR ► CONDUIT HOME -RUN os CEILING MOUNTED OCCUPANCY SENSOR PC PHOTOCELL 11 !1! A A �SLASHES ACROSS CONDUIT INDICATE NUMBER OF WIRES os WALL_ MOUNTED OCCUPANCY SENSOR PNL PANELBOARD WITHIN - SHORT = HOT, LONG = NEUTRAL PHOTOCELL LIGHT SENSOR REC RECEPTACLE(S) —e— ISOLATED GROUND WIRE REF REFRIGERATOR i+ GROUND WIRE (R) RELOCATED EXISTING NOTES AND MISCELLANEOUS SYMBOLS =� CONDUIT TURNS AND CHANGES ELEVATION AT THIS POINT RQMTS REQUIREMENTS CONDUIT STUB -UP > B FLAGNOTE - IDENTIFIES A SPECIFIC ITEM ON A DRAWING. SCL SEATTLE CITY LIGHT —� �-- CONDUIT BREAK COORESPONDS TO A SCHEDULE IN THE ELECTRICAL SET THAT SPD SURGE PROTECTIVE DEVICE --yi CONDUIT CONTINUES ELSEWHERE (NOTED ON PLAN) EXPLAINS DETAILS OR FEATURES OF THAT ITEM. SQ SQUARE FF-3 MECHANICAL FLAG - DEFINES MECHANICAL EQUIPMENT AND SW SWITCH EQUIPMENT CONNECTIONS & CONTROLS COORESPONDS TO DESIGNATIONS IN MECHANICAL PLANS AND TBD TO BE DETERMINED SCHEDULES. COORESPONDS MECHANICAL CONNECTION SCHEDULE ® EQUIPMENT CONNECTION IN THE ELECTRICAL SET. TTB TELEPHONE TERMINAL BOARD l® WALL MOUNTED EQUIPMENT CONNECTION 200 EQUIPMENT FLAG - DEFINES SPECIAL (IE: COOKING) EQUIPMENT TYP TYPICAL MOTOR CONNECTION ON A PLAN AND COORESPONDS TO DESIGNATIONS IN AN UC UNDER COUNTER FAN CONNECTION EQUIPMENT SCHEDULE IN THE ELECTRICAL SET. UG UNDERGROUND UL UNDERWRITER'S LABORATORY DISCONNECT SWITCH REVISION CLOUD' AND FLAG - CLOUD SURROUNDS INFORMATION THAT HAS BEEN REVISED. FLAG IDENTIFIES THE REVISION IN U.O.N. UNLESS OTHERWISE NOTED IZIJ FUSED DISCONNECT SWITCH 1 WHICH THE CHANGES WERE MADE. UTIL UTILITY ® MAGNETIC MOTOR STARTER O DETAIL NUMBER -APPEARS IN FRONT OF A TITLE ON DRAWINGS. VA VOLT AMPERES EP COMBINATION STARTER AND DISCONNECT FL'] ENCLOSED CIRCUIT BREAKER 3 IDENTIFICATION SYMBOL - CROSS REFERENCES INFORMATION IN VS VACANCY SENSOR El.l ONE AREA WITH A DETAIL (TOP #) AND SHEET (BOTTOM #) IN W WATTS [Hil HAND/OFF/AUTO SWITCH ANOTHER IN THE ELECTRICAL SET. WAP WIRELESS ACCESS POINT •E START -STOP PUSHBUTTON SWITCH WC WATER COOLER 0 PUSHBUTTON SWITCH W/o WITHOUT Ski MOTOR RATED SWITCH WP WEATHERPROOF XFMR TRANSFORMER LIGHTING FIXTURE SCHEDULE TYPE I DESCRIPTION I LAMP I WA XTS() I INTERIOR. C1 RECESSED 2x4 TROFFER 2-F28T5 64 .C1D RECESSED 2x4TROFFER WITH 0-10V DIMMING BALLAST. 2-F28T5 64 C1X - SIMILAR TO C1 rvEXCEPT WITH EMERGENCY BACKUP BALLAST. 2 -F28T5 64 F1 RECESSED DOWNLiGHT COMPACT FLUORESCENT 1-CFTR32 36 F1 D (SIMILAR TO F1 EXCEPT WITH 0-10V DIMMING BALLAST. 1-CFTR32 1 36 F1X ISIMiALRTO F1 EXCEPTWITH EMERGENCY BACK UP BALLAST. F2 DECORTIVE PENDANT MOUNTED COMPACT FLUORESCENT 1-CFTR32 36 =2D SIMILAR TO F2 EXCEPT WITH 0-10V DIMMING BALLAST. 1-CFTR32 36 X1 — EMERGENCY EXIT SIGN WITH.. BATTERY BACK. UP. LED - W- 20 REVISIONS No changes shall be made to the scope of v,, rk ivithout prior approval of Tukwila Building Division. 140 i E: �;ee sions will require a new plan submittal and may include additional plan review fees. I DRAWING INDEX E001 ELECTRICAL LEGEND, LIGHTING SCHEDULES E002 ELECTRICAL SPECIFICATIONS ED101 1 ST FLOOR ELECTRICAL DEMOLITION PLAN ED102 2ND FLOOR ELECTRICAL DEMOLITION PLAN E201 1ST FLOOR POWER/COMMUNICATiONS PLAN E202 2ND FLOOR POWER/COMMUNICATIONS PLAN E301 1ST FLOOR LIGHTING PLAN E302 2ND FLOOR LIGHTING PLAN EL401 1 ST FLOOR LIGHTING CALCULATIONS EL402 2ND FLOOR LIGHTING CALCULATIONS E801 RISER DIAGRAM CALCULATIONS E901 PANEL SCHEDULES FILE COPS' Permm imo. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is ackno,idedged: By: Llj� LAA&�tn�_ Date: S t'(;I u1 s if r s BUILDING DIVISION CO W co '=co N LO ti C6 N co U, M p d C:) O CL o- 0 0 L0 o C N ti a7 O o CU O v 0 o at o N co = cc) N N w � N N > > d h N N V7 _0 0- c ca 8o C P (n U Z W r- o CD ti LO Z ul t,j � U :> :5 r— U U3 0 0 v 4_0 i L CU creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS CASE IF ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 ISSUE/REVISION BEVIE SCE FOB H COMPLIA NFPA70: NEC MAR 17 2015 J� City of_Tuk 11aL .. •2r%1^KI RECEIVED CITY OF TUKWILA MAR. 0 9 2015 PERMIT CENTER PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6,2015 SHEET TITLE ELECTRICAL LEGEND, LIGHTING SCHEDULES SHEET NO. E001 © 2015 Cole+Russell Architects, Inc. a 0)z Z� Z0 ZU OLLI U= ~U Z 0¢ LLI � J J N Q � Z W W J x0 0:LL 00 Z F. F Z ZW W 01 Z UU OF 0 U W J F X F r zo z� �3 �W W ~¢a =W =it ¢a co W C� �_ + U J 13001 3: LL LL OF U LLI W � a0 cc CL n. 0 LL 65W ma �x ¢ z N z c 0 N ii = o 2 L �-o Cl) W z 20 U W p oa W 0U � 2 W J �m a DIVISION 16 - ELECTRICAL WORK 16000.0 GENERAL ELECTRICAL CONDITIONS .1 CONFORM TO THE GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS AND RELATED WORK IN OTHER DIVISIONS FOR ALL WORK IN DIVISION 16. SEE DIVISION 1 FOR SEQUENCE OF WORK. .2 WORK INCLUDED: IT IS THE INTENT OF THIS DIVISION OF THE SPECIFICA1ONS AND ACCOMPANYING DRAWINGS TO DESCRIBE AND PROVIDE FOR THE FURNISHINGS, INSTALLING, TESTING AND PLACING IN SATISFACTORY AND SUCCESSFUL OPERATION ALL EQUIPMENT, MATERIALS, DEVICES AND NECESSARY APPURTENANCES TO PROVIDE A COMPLETE ELECTRICAL SYSTEM, TOGETHER WITH SUCH OTHER MISCELLANEOUS INSTALLATIONS AND EQUIPMENT HEREINAFTER SPECIFIED AND/OR SHOWN IN THE PLANS. THE WORK SHALL INCLUDE ALL MATERIALS, APPLIANCES AND APPARATUS NOT SPECIFICALLY MENTIONED HEREIN OR NOTED ON THE PLANS, BUT WHICH ARE NECESSARY TO MAKE A COMPLETE WORKING INSTALLATION OF ALL ELECTRICAL SYSTEMS SHOWN ON THE PLANS OR DESCRIBED HEREIN. EQUIPMENT AND DEVICES FURNISHED AND INSTALLED UNDER OTHER DIVISIONS OF THIS SPECIFICATION (OR BY THE OWNER) SHALL BE COLLECTED UNDER THIS DIVISION. THE DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY AND WHAT IS CALLED FOR IN EITHER IS BINDING AS IF CALLED FOR IN BOTH. BY SUBMITTING A BID THE CONTRACTOR IS ACKNOWLEDGING THAT HE/SHE HAS MADE A THOROUGH EXAMINATION OF THE CONTRACT DOCUMENTS, EXISTING SITE AND BUILDING CONDITIONS, AND HAS DETERMINED THAT THESE DOCUMENTS DO SUFFICIENTLY DESCRIBE THE SCOPE OF CONSTRUCTION WORK REQUIRED UNDER THIS CONTRACT. .3 SCOPE OF BASIC BID: INCLUDED IN DIVISION 16 IS ALL WORK AND RELATED ITEMS NECESSARY TO PROVIDE ALL ELECTRICAL INSTALLATIONS EXCEPT AS SPECIFICALLY EXCLUDED. IN GENERAL, THIS INCLUDES ALL LABOR, EQUIPMENT, TOOLS, SUB -CONTRACTORS (SKILLED TRADES, LICENSES, PERMITS, PROGRAMMERS, ETC), REQUIRED TO COMPLETE THE ELECTRICAL WORK. .4 DEFINITIONS: A. PROVIDE SHALL BE INTERPRETED AS TO FURNISH AND INSTALL. B. FURNISH SHALL BE INTERPRETED AS TO PURCHASE AND DELIVER TO THE SITE READY FOR INSTALLATION, PROTECTED FROM THE ELEMENTS AND FROM VANDALISM AND THEFT. C. INSTALL SHALL BE INTERPRETED AS TO MAKE READY FOR USE AND TO MAKE COMPLETE AND OPERATIONAL. .5 PROTECTION THE CONTRACTOR SHALL STORE AND GUARD ALL EQUIPMENT BEFORE INSTALLATION AND SHALL PROTECT SAME AND SHALL REPLACE ANY EQUIPMENT THAT HAS BEEN DAMAGED PRIOR TO FINAL ACCEPTANCE. 16010.0 GENERAL PROVISIONS: PROVIDE COMPLETE AND FULLY OPERATIONAL ALL ELECTRICAL SYSTEMS SPECIFIED AND/OR SHOWN ON THE PLANS, ALONG WITH POWER CONNECTIONS TO EQUIPMENT, FURNISHED UNDER OTHER DIVISIONS OF THE SPECIFICATIONS. .1 CODES: CONFORM AND COMPLY WITH THE FOLLOWING CODES AND STANDARDS AS PRESENTLY APPLICABLE: D. 2014 NATIONAL ELECTRICAL CODE E. 2012 WASHINGTON STATE ENERGY CODE F. 2012 SEATTLE ENERGY CODE G. NFPA 72 H. ANSI/BICSI/TIA/EIT CABLING & COMMUNICATIONS STANDARDS. I. ALL STATE AND LOCAL CODES, ORDINANCES AND REGULATIONS .2 PERMITS AND FEES: OBTAIN AND PAY FOR ALL REQUIRED LICENSES, PERMITS AND INSPECTIONS. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS AND INSPECTIONS REQUIRED BY LAWS, ORDINANCES AND RULES GOVERNING WORK SPECIFIED HEREIN. THE CONTRACTOR SHALL ARRANGE FOR INSPECTION OF THE WORK BY THE INSPECTORS AND SHALL GIVE THE INSPECTORS ALL NECESSARY ASSISTANCE IN THEIR WORK OF INSPECTION. THE CONTRACTOR SHALL CONSULT WITH AND FOLLOW THE REQUIREMENTS OF THE LOCAL FIRE, POWER, TELEPHONE/DATA AND TELEVISION UTILITIES SERVING THE AREA AND SHALL COORDINATE HIS WORK WITH THEM. UTILITY CONNECTION AND HOOK-UP CHARGES FOR POWER, TELEPHONE/DATA AND TELEVISION SHALL BE PAID BY THE OWNER DIRECTLY TO THE UTILITY. THE ELECTRICAL CONTRACTOR IS REQUIRED TO PROVIDE ANY AND ALL COORDINATION NECESSARY TO SUPPORT THE UTILITY CONNECTION, FILE FOR APPLICATION OF SERVICE (OR ASSIST THE OWNER IN FILING FOR APPLICATION OF SERVICE) AND COORDINATE DATES FOR SERVICE WITH THE UTILITIES. .3 MATERIALS: SHALL BE NEW AND EACH TYPE OF MATERIAL FURNISHED SHALL BE OF THE SAME MAKE AND SHALL BE THE STANDARD PRODUCTS OF MANUFACTURERS, REGULARLY ENGAGED IN THE PRODUCTION OF SUCH MATERIALS AND SHALL BE THE MANUFACTURER'S LATEST STANDARD DESIGN. ALL MATERIALS AND EQUIPMENT INSTALLED, INCLUDING LIGHT FIXTURES SHALL HAVE BEEN TESTED AND LISTED BY UNDERWRITERS LABORATORIES OR OTHER NATIONALLY RECOGNIZED TESTING LABORATORY AND SHALL BE SO LABELED IN ACCORDANCE WITH OSHPD CODE APPLICATION NOTICE 3-110-2. .4 WARRANTY: PROVIDE A WRITTEN WARRANTY THAT THE DIVISION 16 WORK IS FREE FROM MECHANICAL AND ELECTRICAL DEFECTS. CONTRACTOR SHALL REPLACE AND REPAIR, TO THE SATISFACTION OF THE ENGINEER, ANY PART OF THE INSTALLATION WHICH MAY FAIL WITHIN A PERIOD OF TWELVE MONTHS AFTER THE CERTIFICATE OF FINAL ACCEPTANCE. .5 CONTRACT DRAWINGS: THE ELECTRICAL DRAWINGS ARE INTENDED TO SERVE AS WORKING DRAWINGS FOR GENERAL LAYOUT. THE EQUIPMENT LAYOUT IS DIAGRAMMATIC AND UNLESS SPECIFICALLY DIMENSIONED OR DETAILED, DOES NOT INDICATE ALL FITTINGS, HARDWARE OR APPURTENANCES REQUIRED FOR A COMPLETE OPERATING INSTALLATION. ANYTHING SHOWN ON THE DRAWINGS BUT NOT COVERED IN THE SPECIFICATIONS, OR ANYTHING SHOW IN THE SPECIFICATIONS BUT NOT COVERED ON THE DRAWINGS SHALL BE AS IF COVERED AND SHOWN IN BOTH. IN CASE OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS, THE ENGINEER SHALL SELECT THE METHOD/PRODUCT AND INSTALLATION THEREOF. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS BEFORE PROCEEDING WITH THE WORK. WIRING DIAGRAMS ARE NOT INTENDED TO INDICATE THE EXACT COURSE OF RACEWAYS OR EXACT LOCATION OF EQUIPMENT. RACEWAY AND OUTLET/DEVICE LOCATIONS ARE APPROXIMATELY CORRECT AND ARE SUBJECT TO REVISION AS MAY BE NECESSARY OR DESIRABLE AT THE TIME OF INSTALLATION. PRECISE LOCATION IN EVERY CASE SHALL BE SUBJECT TO THE ENGINEER'S APPROVAL. .6 RECORD DRAWINGS: ONE (1) FULL PRINT SET AT THE JOB SITE, KEPT CONTINUALLY UPDATED. SUBMIT TO ARCHITECT AT COMPLETION OF PROJECT. .7 MAINTENANCE MANUALS: COMPLETE FOR EVERY SYSTEM. HARDBOARD COVERS WITH 3 RING BINDERS. 16050.0 EXISTING SYSTEMS .1 EXISTING SYSTEMS MAINTAINED: MAINTAIN EXISTING SYSTEMS IN OPERATION DURING CONSTRUCTION. VISIT THE SITE PRIOR TO BID TO VERIFY EXISTING CONDITIONS, DEMOLITION WORK AND NEW WORK REQUIRED. ANY EXISTING WIRING SERVING DEVICES TO REMAIN IN SERVICE AND WHICH IS INTERRUPTED BY WORK PERFORMED UNDER THIS CONTRACT SHALL BE REROUTED TO MAINTAIN CIRCUIT CONTINUITY. INCLUDE ALL COSTS IN BID. .2 EXISTING SYSTEMS CONCEALED: THE ELECTRICAL DRAWINGS SHOW PORTIONS OF THE EXISTING ELECTRICAL SYSTEMS WHICH ARE TO REMAIN, BE REMOVED OR BE MODIFIED AS A PART OF THE CONTRACTOR'S WORK. CONCEALED FEATURES OF THE EXISTING SYSTEMS ARE DERIVED FROM RECORD DRAWINGS AND THE ENGINEER'S BEST JUDGMENT OF THE CONFIGURATION, BUT NO GUARANTEE IS MADE AS TO THEIR CORRECTNESS. THE CONTRACTOR SHALL INSPECT THE EXISTING INSTALLATION PRIOR TO BIDDING AND SHALL MAKE HIS OWN JUDGMENT AS TO THE WORK REQUIRED TO PROVIDE A COMPLETE INSTALLATION AND DEMOLITION WITHIN THE INTENT OF THE CONTRACT DOCUMENTS. .3 EXISTING CIRCUITS: THE DRAWINGS SHOW PORTIONS OF THE EXISTING ELECTRICAL SYSTEM DERIVED FROM THE EXISTING RECORD DRAWINGS WHICH ARE INCOMPLETE AND. NO GUARANTEE IS MADE TO THEIR CORRECTNESS. PRIOR TO THE START OF CONSTRUCTION THE CONTRACTOR SHALL PERFORM A CIRCUIT VERIFICATION TEST OF THE EXISTING RECEPTACLES SHOWN ON THE ELECTRICAL DRAWINGS UTILIZING A CIRCUIT TRACER. THIS INFORMATION SHALL BE MARKED UP ON A COPY OF THE CONTRACT DRAWINGS AND FORWARDED TO THE ENGINEER SO THAT THE CONTRACT DRAWINGS CAN BE CORRECTED TO SHOW THE ACTUAL CIRCUIT NUMBERS TO BE UTILIZED. AT THE SAME TIME THE CIRCUITS LISTED AS "EXISTING CIRCUIT" ON THE PANEL SCHEDULES SHALL BE TRACED OUT AND THE ACTUAL ROOM NUMBER AND LOAD NAME AND WATTAGE IDENTIFIED ON A MARKED UP COPY OF THE PANEL SCHEDULE AND FORWARDED TO THE ENGINEER. .4 MATERIALS: EXISTING MATERIALS AND EQUIPMENT REMOVED AS PART OF THIS WORK MAY NOT BE REINSTALLED UNLESS SPECIFICALLY NOTED ON THE DRAWINGS. EXISTING MATERIALS NOT TO BE REINSTALLED UNLESS SELECTED FOR RETENTION BY THE OWNER, WHICH THEN SHALL BE DELIVERED TO A LOCATION ON THE PREMISES SELECTED BY THE OWNER. .5 DEMOLITION: ELECTRICAL DEVICES, LIGHTING FIXTURES, AND RACEWAY SYSTEMS WITHIN THE PROJECT AREA THAT ARE NO LONGER IN USE AS A RESULT OF THIS CONTRACT SHALL BE REMOVED UNLESS OTHERWISE NOTED TO REMAIN OR BE REINSTALLED. .6 POWER OUTAGES: SCHEDULE ELECTRICAL SYSTEM(S) OUTAGES WITH THE OWNER AT LEAST 48 HOURS PRIOR TO PROPOSED OUTAGE.. ELECTRICAL SYSTEM(S) OUTAGE TO OWNER OCCUPIED AREAS SHALL NOT BE PERMITTED FROM 7:OOA.M. TO 6:OOP.M. ON ANY DAY OF THE WEEK. PREMIUM TIME SHALL BE INCLUDED IN THE BASE BID FOR ELECTRICAL SYSTEM(S) OUTAGES AND FOR OTHER WORK AS REQUIRED BY THE SCHEDULE OR OTHER DIVISIONS OF THE SPECIFICATIONS. 16100.0 BASIC MATERIALS AND METHODS: INCLUDES GENERAL REQUIREMENTS FOR MATERIALS AND INSTALLATION METHODS, CUTTING BUILDING CONSTRUCTION, PAINTING, CLEAN-UP, AND WORKMANSHIP. .1 SUBSTITUTIONS: SHALL BE REVIEWED BY THE ENGINEER FOR APPROVAL/REJECTION PRIOR TO BID. .2 WORKMANSHIP: SHALL BE OF THE BEST QUALITY AND PERFORMED BY EXPERIENCED ELECTRICIANS UNDER SUPERVISION OF AN EXPERIENCED FOREMAN. .3 SUBMITTALS: AFTER AWARD OF CONTRACT SUBMIT THREE COMMON BOUND BROCHURES (ONE COPY RETURNED TO CONTRACTOR) CONTAINING CATALOG CUTS AND/OR SHOP DRAWINGS FOR THE FOLLOWING ITEMS: WIRING DEVICES MOTOR STARTERS DISCONNECTS AND FUSED SWITCHES LIGHTING FIXTURES AND BALLASTS .4 CUTTING AND PATCHING: -DO NOT CUT STRUCTURAL MEMBERS. ALL CONSTRUCTION MATERIALS DAMAGED OR CUT INTO DURING THE INSTALLATION OF THIS WORK MUST BE REPAIRED OR REPLACED WITH MATERIALS BY SKILLED LABOR EXPERIENCED IN THAT PARTICULAR BUILDING TRADE. .5 PAINTING: REPAINT ANY ELECTRICAL ITEMS SCRATCHED OR MARRED IN SHIPMENT OR INSTALLATION. .6 CLEAN UP: CONTINUALLY REMOVE DEBRIS, CUTTINGS, CRATES, CARTONS, ETC. CAREFULLY CLEAN WIRING DEVICES, COVER PLATES, LIGHT FIXTURES, ETC., TO REMOVE PAINT AND PLASTER, ETC. 16110.0 RACEWAYS: PROVIDE RACEWAY SYSTEM COMPLETE AND IN CONFORMANCE WITH CODE. INSTALL RACEWAYS CONCEALED IN CONSTRUCTION FOR ALL AREAS UNLESS EXPOSED RACEWAYS ARE SPECIFICALLY SHOWN. .1 INTERIOR RACEWAYS: ELECTRICAL METALLIC TUBING (EMT) WITH STEEL COMPRESSION OR SET SCREW FITTINGS. INDENTOR, DRIVE -ON AND PRESSURE CAST ON DIE CAST TYPE SET SCREW FITTINGS ARE NOT ACCEPTABLE.. UNLESS OTHERWISE NOTED 1 /2" MINIMUM. FLEXIBLE RACEWAYS: GALVANIZED FLEXIBLE STEEL CONDUIT FOR DRY LOCATIONS. MAXIMUM LENGTH 6 FEET IN ANY GROUND RETURN PATH. NOT PERMITTED FOR EMERGENCY SYSTEM WIRING. .2 SURFACE METAL RACEWAY: FORMED STEEL TYPE. STANDARD FACTORY PAINTED FINISH. PROVIDE FOR ALL EXPOSED RACEWAYS IN FINISHED AREAS, INSTALL PARALLEL TO A BUILDING SURFACE (I.E. WALL, CEILING, FLOOR). .3 RACEWAY PENETRATIONS: PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M CP-2: FIRE BARRIER CAULK UL LISTED SYSTEM NO. WL1001 16120.0 CONDUCTORS AND TERMINATIONS: PROVIDE ALL WIRE AND CABLE COMPLETE. .1 COPPER, INSULATED FOR 60OV. ALUMINUM OR COPPER CLAD ALUMINUM CONDUCTORS NOT PERMITTED. TYPE THW, THHN/THWN OR XHHW. NUMBER 12 AWG MINIMUM FOR POWER AND LIGHTING CIRCUITS. .2 SPLICES: SOLDERLESS TYPE ONLY. PREINSULATED "TWIST -ON" TYPE (LIMITED TO SIZE #10 AND SMALLER). BOLT OR COMPRESSION SET TYPE WITH APPLICATION OF PREFORMED INSULATED COVER, HEAT SHRINKABLE TUBING OR PLASTIC INSULATED TAPE ACCEPTABLE FOR ALL SIZES. .3 TERMINATIONS: COMPRESSION SET, BOLTED OR SCREW TERMINAL. CONDUCTORS #12 AND SMALLER SHALL UTILIZE EYE OR FORKED TONGUE TYPE COMPRESSION SET TERMINATOR WHEN TERMINATION IS TO A BOLTED SCREW SET TYPE TERMINAL BLOCK OR TERMINAL CABINET. 16122.0 METAL CLAD CABLE: NOT PERMITTED UNLESS SPECIFICALLY AUTHORIZED IN WRITING BY PROJECT MANAGER. 16130.0 OUTLET AND PULL BOXES: PROVIDE OUTLET BOXES FOR DEVICES SUCH AS RECEPTACLES, SWITCHES AND LIGHT FIXTURES AND PULL BOXES AS REQUIRED IN THE CONDUIT SYSTEM PER THE NATIONAL ELECTRICAL CODE. .1 INTERIOR WIRING: PRESSED STEEL, ZINC COATED WITH BRACKETS AND PLASTER RING WHERE APPLICABLE. OUTLET BOXES SHALL BE FIRMLY ANCHORED TO WALL STUDS, CUT IN BOXES ARE NOT PERMITTED. MOUNT OUTLET BOXES FOR RECEPTACLES AND OTHER DEVICES AT 18", OR MATCH EXISTING OUTLET HEIGHTS. 16140.0 SWITCHES AND RECEPTACLES: PROVIDE ALL WIRING DEVICES AND COVERPLATES. A COLOR: REFER TO GENERAL NOTES AND FLAG NOTES ON PLANS. COORDINATE WITH ARCHITECT PRIOR TO ORDERIN( THE STANDARD DEVICE & FACEPLATE COLOR FOR TISHMAN-SPEYER, 520 PIKE BUILDING IS IVORY, CONFIRM ALL DEVICE/FACEPLATE COLORS WITH ARCHITECT/OWNER PRIOR TO ORDERING EQUIPMENT. .2 SWITCHES: SPECIFICATION GRADE, FEDERAL SPECIFICATION WS-896, BACK AND SIDE WIRED, RATED 277 VOLT, 20 AMP. PROVIDE SINGLE POLE, DOUBLE POLE, KEYED, 3-WAY, 4-WAY, PILOT LIGHT, LOCKING TYPE OR AS REQUIRED. ARROW HART 1991-I, BRYANT 4901-I, EAGLE 2221V, GENERAL ELECTRIC GE 5951-2G, HUBBELL 1221-I, LEVITON 1221-I, PASS & SEYMOUR 20AC1-1. .3 OCCUPANCY 5EN50R SVVITCIIES: SPECIFICATION GRADE, INFRARED OCCUPANCY 5EN5UK RATED 1800 VA ® 120 VOLTS, 4000 VA @ 277 VOLTS WITH SELF ADAPTIVE TECHNOLOGY. 180 DEGREE FIELD OF VIEW, 2100 SF OF COVERAGE. LEVITON ODS15-ID-I. .4 RECEPTACLES OFFICE AREAS: SPECIFICATION GRADE, FEDERAL SPECIFICATION WC-596F, BACK AND SIDE WIRED, DUPLEX NEMA 5-15R CONFIGURA11ON (15 AMP, 120V), NYLON FACE, UNLESS SHOWN OTHERWISE. ARROW HART 5252-I, BRYANT 5252-I, EAGLE 5252V, GENERAL ELECTRIC GE 5252-2, HUBBELL 5252-I, LEVITON 5252-I, OR PASS & SEYMOUI 5252-I. .5 GROUND FAULT RECEPTACLES: SPECIFICATION GRADE .DUPLEX RECEPTACLE WITH 4 - 6 MILLIAMPS LEAKAGE CURRENT TRIP LEVEL. IVORY COLOR. HUBBELL GF-5262, PASS & SEYMOUR 1591-SI. .6 INTERIOR DEVICE PLATES: REFER TO SECTION 16140.1 .7 MULTIOUTLET ASSEMBLY: OUTLET SPACING SHALL BE 12" ON CENTER EXCEPT SHALL BE LOCATED WITHIN 0'-8" OF EACH END AND NO RECEPTACLES SHALL BE INSTALLED OVER SINKS. ALL ASSEMBLIES SHALL CONTAIN GREEN GROUND WIRE. PROVIDE .040" THICK STEEL ASSEMBLY WITH STANDARD FACTORY BUFF PAINTED FINISH. WIREMOLD 20GBA-12 SERIES OR EQUIVALENT BY WALKER. 16500.0 LIGHTING: PROVIDE A LIGHTING SYSTEM AS SHOWN ON THE CONTRACT DRAWINGS COMPLETE AND FULLY OPERATIONAL AND IN CONFORMANCE WITH CODE AND U.L. LISTING REQUIREMENTS. .1 CATALOG NUMBERS: ARE A DESIGN SERIES REFERENCE ONLY AND THE SIZE OF THE FIXTURE PROVIDED SHALL CORRESPOND WITH THE NUMBER OF LAMPS, WATTAGE CEILING TYPE AND/OR SIZE SHOWN. VERIFY ACTUAL REQUIREMEN- PRIOR TO ORDERING FIXTURES. .2 LAMPS: FLUORESCENT TYPE: BI-PIN, T-8 RAPID START, 32 WATT, 3500 K COLOR TEMPERATURE UNLESS OTHERWISE NOTED. COMPACT TRT(TRIPLE-TUBE) AND DTT(DOUBLE-TUBE), 3500 K COLOR TEMPERATURE UNLESS OTHERWISE NOTED. FOR FLUORESCENT LAMPS OPERATED ON DIMMING BALLASTS, OPERATE LAMPS AT FULL OUTPUT FOR 100 HOURS (CONTINUOUS BURN) BEFORE DIMMING. .3 ELECTRONIC BALLASTS: SHALL BE U.L AND CMB (WHERE APPLICABLE) LISTED, NON -PCB, HIGH POWER FACTOR TYF MEETING THE REQUIREMENTS OF IEEE PUBLICATION 587, CATEGORY A (TRANSIENTS) AND FCC PART 18. TOTAL HARMONI DISTORTION SHALL BE LESS THAN 20% OF THE INPUT CURRENT. CURRENT CREST FACTOR SHALL NOT BE GREATER THAI 1.6. OPERATION FREQUENCY SHALL BE BETWEEN 20 AND 60 KHZ. BALLASTS SHALL BE WARRANTED BY THE MANUFACTURER FOR A PERIOD OF NOT LESS THAN THREE YEARS. EBT SSB1/LH SERIES, MOTOROLA MRN SERIES, VALMONT SR/GO1 SERIES OR AS SPECIFICALLY NOTED IN THE LIGHT FIXTURE SCHEDULE. .4 FIXTURE SUPPORT. PROVIDE TWO #14 EARTHQUAKE CHAINS OR #9 WIRE SECURED (AT DIAGONALLY OPPOSITE FIXTURE CORNERS) TO STRUCTURAL MEMBERS ABOVE SUSPENDED CEILING FOR EACH RECESSED FLUORESCENT FIXTURE. .5 PROVIDE LIGHTING SYSTEM(S) COMMISIONING PER THE 2012 WASHINGTON STATE ENERGY CODE (WSEC) PROVIDE LIGHTING CONTROL (TIMECLOCKS, OCCUPANCY SENSORS, PHOTOCELLS, ETC.) ADJUSTMENTS AND TRAINING TO THE OWNER PER WSEC AS REQUIRED, REFER TO WSEC 408.3 FOR REQUIREMENTS. 16721.0 FIRE ALARM SYSTEM: PROVIDE A ZONED, NON -CODED, ANNUNCIATED FIRE DETECTION AND ALARM SYSTEM THAT FULLY COMPLIES WITH FEDERAL, STATE AND LOCAL FIRE CODES. THE SYSTEM SHALL BE AN EXTENSION OF THE CORE AND SHELL BUILDING SYSTEM WHICH IS AN ADDRESSABLE SYSTEM. IF ANY CONFLICT OCCURS BETWEEN GOVERNMENT ADOPTED CODE RULES AND THESE CONTRACT DOCUMENTS, THE CODES ARE TO GOVERN. .1 OPERATION: ACTIVATION OF ANY INITIATION DEVICE SHALL IMMEDIATELY CAUSE ALL FIRE ALARM SPEAKERS TO SOUND A CONTINUOUS CHIME TONE SIGNAL, VISUAL ALARM LIGHTS TO FLASH, RELEASE SMOKE BARRIER DOORS, ILLUMINATE THE ZONE ANNUNCIATOR LIGHT, TRANSMIT AN ALARM TO THE FIRE DEPARTMENT. AIR HANDLING EQUIPMENT AFFECTING THE ZONE OF THE FIRE TO BE AUTOMATICALLY SHUTDOWN ONLY WHEN ACTIVATED BY THE SMOKE DETECTOR LOCATED IN THE SUPPLY AIR DUCT DOWNSTREAM OF THE FILTERS. .2 SUPERVISION: THE SYSTEM SHALL BE SUPERVISED TO SOUND AN AUDIBLE AND VISUAL TROUBLE SIGNAL UPON THE OCCURRENCE OF ANY OPEN OR GROUNDED CIRCUITS. PROVIDE A SEPARATE INDICATOR. LAMP FOR EACH ZONE. .3 SPRINKLER SYSTEM MONITORING: COORDINATE WITH THE SPRINKLER SYSTEM SUBCONTRACTOR AND PROVIDE CIRCUITS AND ANNUNCIATION AS REQUIRED BY THE AHJ TO SUPERVISE PIV, OSY GATE VALVE POSITIONS AND WATER FLOW SWITCHES. .4 CONTRACTOR DESIGN: RACEWAYS, ROUTING AND SYSTEM WIRING IS NOT SHOWN ON THE PLANS AND IT SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM SYSTEM SUPPLIER TO DESIGN CONDUIT ROUTING AND WIRING AND TO SHOW THE SAME ON THE SHOP DRAWINGS. CIRCUITS SHALL BE CLASS B. .5 SHOP DRAWINGS: PREPARE FLOOR PLAN BACKGROUNDS AND SHOW CONDUIT ROUTING, DEVICE LOCATIONS, END OF LINE RESISTORS, AND WIRE COUNT BETWEEN DEVICES. SHOW FIRE ALARM ZONES. UPDATED DRAWINGS OF THE ORIGINAL FIRE ALARM SHOP DRAWINGS ARE ACCEPTABLE. SUBMIT DRAWINGS AND OBTAIN APPROVAL OF THE "AUTHORITY HAVING JURISDICTION" (AHJ). .6 APPROVED MANUFACTURERS: MATCH EXISTING EQUIPMENT (PYROTONICS EQUIPMENT SHOWN FOR REFERENCE ONLY). .7 COMPONENTS: SHALL BE MANUFACTURERS STANDARD. MANUAL STATIONS: BREAK GLASS, NON -CODED, SEMI -FLUSH MOUNTED WITH FIRE RED ENAMEL FINISH. PYROTRONICS MSI-1 OB. SMOKE DETECTORS: PHOTOELECTRIC TYPE, LOW PROFILE, SEMI -FLUSH MOUNTED WITH VISUAL INDICATION OF TROUBLE/ALARM CONDITION. PYROTRONICS FP-11 WITH DB-11 BASE. HEAT DETECTORS: COMBINATION SPOT/RATE OF RISE TYPE, NON SELF RESTORING WITH INDICATION OF ACTUATED CONDITION. CHEMTRONICS #6031356. DUCT SMOKE DETECTORS: PHOTOELECTRIC TYPE WITH REMOTE TEST STATION AND ALARM INDICATOR. IN DUCT TYPE: SUITABLE FOR 0-600 FT/ MIN AIR VELOCITY. PYROTRONICS AD-11XPR. SAMPLING TUBE TYPE: DESIGN AND DIMENSIONS AS RECOMMENDED BY THE MANUFACTURER FOR THE SPECIFIC DUCT SIZE, AIR VELOCITY, AND INSTALLATION CONDITIONS WHERE APPLIED. PROVIDE AUXILIARY RELAY PROGRAMMED TO CLOSE THE ASSOCIATED SMOKE DAMPER UPON AC11VA-AON OF DUCT SMOKE DETECTOR AND FUTURE INDEPENDENT CONTROL FROM THE BUILDING AUTOMATION SYSTEM. PROVIDE A REMOTE INDICATOR LIGHT AND TEST STATION WHEN THE SMOKE DETECTOR IS NOT READILY VISIBLE WHEN STANDING IN THE ROOM. SIMILAR TO SIMPLEX 2098-9648. VISUAL ALARM LIGHTS: VISUAL ALARM LIGHTS: LED STROBE LIGHTS, UL LISTED TO STANDARD 1971. WALL MOUNTED WHITE HOUSING WITH RED "FIRE" LETTERING. WHEELOCK EXCEDER SERIES (15/30/75/95 CD); STROBE ONLY #LSTWC. SPEAKER ONLY: MULTI -TAPPED SPEAKER WITH LINE MATCHING TRANSFORMER FOR 1/4, 1/2, 1 OR 2 WATT OUTPUT ON A 25 VOLT LINE. FREQUENCY RANGE 400-4000 HZ PRODUCING 84DB AT 10 FEET AT 1 WATT INPUT. UL LISTED TO STANDARD 1480. WHITE HOUSING WITH RED `FIRE" LETTERING WHEELOCK EXCEDER SERIES ; #LSPKWC COMBINATION SPEAKER/ VISUAL ALARM LIGHT: MUL11-TAPPED SPEAKER WITH LINE MATCHING TRANSFORMER FOR 1 /4, 1 /2, 1 OR 2 WATT OUTPUT ON A 25 VOLT LINE. FREQUENCY RANGE 400-4000 HZ PRODUCING 84DB AT 10 FEET AT 1 WATT INPUT. UL LISTED TO STANDARD 1480. VISUAL ALARM LIGHT 110 CANDELA, U.L LISTED TO STANDARD 1971. WHITE HOUSING WITH RED "FIRE" LETTERING. WHEELOCK EXCEDER SERIES ; SPEAKER/STROBE CEILING #LSPSTWC .8 INSTALLATION: OBTAIN A PERMIT AND APPROVED SHOP DRAWINGS FROM THE AHJ PRIOR TO INSTALLING EQUIPMENT. ALL WIRING SHALL BE CONTAINED IN STEEL RACEWAYS. AFFIX PERMANENT WIRE MARKERS TO ALL CONDUCTORS AT TERMINATIONS. NUMBER 16 GAUGE WIRE SHALL HAVE A MAXIMUM OF 7 STRANDS. .9 TESTING: TESTING SHALL BE IN COMPLIANCE WITH NFPA 72, CHAPTER 7. IN ADDITION, TEST EACH DEVICE, ALL FEATURES OF THE SYSTEM ON NORMAL AND BATTERY POWER AND DEMONSTRATE SATISFACTORY OPERATION TO THE ENGINEER AND THE AUTHORITY HAVING JURISDICTION. OBTAIN APPROVAL OF THE AHJ IN WRITING. .10 RECORD DOCUMENTS: PROVIDE OPERATION AND MAINTENANCE MANUALS AND RECORD DRAWINGS TO SHOW ACTUAL ROUTING OF RACEWAYS, CABLE TYPES AND NUMBERS AND WIRING DIAGRAMS. .11 INSTRUCTION: DESCRIBE AND DEMONSTRATE ALL MAINTENANCE AND OPERATIONAL ASPECTS OF THE SYSTEM TO PERSONNEL SELECTED BY THE OWNER. 16740.0 TELEPHONE, COMPUTER SYSTEMS: PROVIDE RACEWAY AND OUTLET BOXES READY FOR THE INSTALLA11ON OF CABLES BY OTHERS. .1 WALL OUTLETS: PROVIDE A 4" SQUARE, 2-1/8" DEEP OUTLET BOX AND SINGLE GANG PLASTER RING. .2 RACEWAYS: PROVIDE A 3/4" RACEWAY FROM EACH TELEPHONE/ COMPUTER OUTLET TO THE CEILING SPACE. MULTIPLE OUTLET BOXES SHALL NOT BE CONNECTED TOGETHER BY A COMMON RACEWAY HOWEVER, THE VERTICAL RACEWAYS MAY BE ROUTED TO AN ACCESSIBLE J-BOX ABOVE THE CEILING AND THEN HOME RUN TO THE CORRIDOR CEILING WITH A SINGLE RACEWAY. PROVIDE PLASTIC BUSHING ON ALL RACEWAY ENDS. .3 CONDUCTORS, OUTLETS, AND COVERPLATES: BY LOW -VOLTAGE CONTRACTOR. .4 PULL CORDS: PROVIDE A NYLON TYPE PULL CORD IN EACH RACEWAY AND SECTION OF CABLE TRAY BACK TO THE TELEPHONE TERMINAL BOARD. FOR WPA70 NEC MAR 17 W5 C►ty ®� �rietP�il1 RECEIVED CITY OF TUKWILA. MAR. 0 9 2015 PERMIT CEi-4TEf oco m N C Csi t, cn N coM to ti o p- M a N a a LO o o 4t N ^ pp Oco 1X"' ¢ CU C i 0 � .0 C CU U 0 U-) o o Co cD N N NLO N cc m :u o L°in >-Zc CDoCO o LO o in 0) Cn W 70 U V CU creating extraordinary spaces www.cr-architects.com 800.469A949 CONSULTANTS CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone; 425-402-9400 Fax: 425-402-9402 ISSUE/REVISION PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6.2015 SHEET TITLE ELECTRICAL SPECIFICATIONS SHEET NO. E002 © 2015 Cole+Russell Architects, Inc. v\l — a � U z Z Z F � Z W 0, F= U Z Oa F J J w m �n O� zW W J FU Z OF W N Z U U O F- -U =a W� . 0 Z W W- t= a =W d° a. a j WJ M_ U W 2 J '0 0 LL �w W a0 =a aV LL >U Fn W a 0i oz a� W� 0= Z;0 F N ii 0 0 K w to W _ SO Z: 2O to U W oW a �v O = W J t- m a j I ' NORTH 1 ST FLOOR ELECTRICAL DEMOLITION PLAN SCALE: 1/8" = 1'-0" , — -�\ P 1 LEGEND - DEMOLITION PLAN DEVICES SHOWN BOLD & DASHED ARE TO BE REMOVED. DEVICES SHOWN IN LIGHT LINEWEIGHT ARE EXISTING TO REMAIN — MAINTAIN I:Q CIRCUIT. GENERAL NOTES - DEMOLITION PLAN 1, REMOVE ALL DEVICES & ACCESSOCIATED CIRCUITRY SHOWN ON DEMOLITION PLAN. 2. EXISTING ELECTRICAL DEVICES ARE BASED ON RECORD DRAWINGS. NOT ALL DEVICES TO BE REMOVED MAY BESHOWN. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. 3. MAINTAIN CIRCUITS TO ALL EXISTING ELECTRICAL DEVICES TO REMAIN. 4. VERIFY EXISTING CIRCUITS. f REVIEWED WR �:: C®PLI �®C NEC Nf PA BAR 1 °� �015 CO• .-fu dila 11 t ity _ _ RECEIVED CITY OF TUKWILA MAR. 0 9 2015 PERMIT CENTER CO o � co N � m O Cvj N co M C W '5 0 Cq a a o N to OCn o �t N C" co 0 ~ Q o a� o U 0 con o o_ oco m o N yco � d N y .co N T j d 3 ca Q co a C N O C 2 N N 7 Z (n o t- CD co o co LO o co t-- U') creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUEIREVISION PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6.2015 SHEET TITLE 1ST FLOOR ELECTRICAL DEMOLITION PLAN SHEET NO. ED1 01 © 2015 Cole+Russell Architects, Inc. \ a m CU zZ a� ~U Z W O U= 1= U Z of 0¢ J LU Cr 0 W ? W =o F U 00 ZH LU Z UU 0� DU W J CL WW . 0 z H �o W� ~ a =n. W Wcc Qa w Cn- it U W 2 J 0 ' 0 roL r LL W� n. 0 0. a0 >W �a 0 Z •! ¢� 0 =3W o1- s 0 F N .m o _ 0 U � 0 N CoW z� n Cn o oa w to U 0O 2 LU J rm a. i SECOND FLOOR ELECTRICAL DEMOLITION PLAN SCALE: 1/8" = 1'-0" ---................... 1 LEGEND — DEMOLITION PLAN DEVICES SHOWN BOLD & DASHED ARE TO BE REMOVED. 14 Q DEVICES SHOWN IN LIGHT LINEWEIGHT ARE EXISTING TO REMAIN — MAINTAIN �D CIRCUIT. GENERAL NOTES — DEMOLITION PLAN 1. REMOVE ALL DEVICES & ACCESSOCIATED CIRCUITRY SHOWN ON DEMOLITION PLAN. 2. EXISTING ELECTRICAL DEVICES ARE BASED ON RECORD DRAWINGS. NOT ALL DEVICES TO BE REMOVED MAY BESHOWN. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. 3. MAINTAIN CIRCUITS TO ALL EXISTING ELECTRICAL DEVICES TO REMAIN. 4. VERIFY EXISTING CIRCUITS. RECEIVED CITY OF TUKWILA MAR. 0 9 2015 PERMIT CENTER CD LO co m coo, o_ co N Z�; m O I--f+9 N co C+1 � co d M d N a CL N N N O o N ti aD 0 0 Q _ 0 N C > 0 N U 0 uoi � v o o 9r o N N N N N � N � . InN U) Ln Cn 70 d c O c > tm Z Cn CDr. o cD a)cfl Un o CD ti LO H Z z w Q u U 0 0 Cn creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS � CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone; 425-402-9400 Fax: 425-402-9402 ISSUE/REVISION PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6.2015 SHEET TITLE 2ND FLOOR ELECTRICAL DEMOLITION PLAN SHEET NO. E uffm4'1 02 © 2015 Cole+Russell Architects, Inc. r— pall } — co Z- ¢F ~U zw O U= ~U J J oUj LL re, zW =o F U 00 ZF W CO Z UU 0� 00 W —, Fa zo z� U ~a =w a� Qa J W co- it = U W 2 00 w 0 F �U W n. Oa X n. 0 W V- > W 0- CO %U� W oZ Q� o 7 W in s 08 N ai o W 0 r H0 m co W Z= Wo oa w 0U 0 Hm d l ST FLOOR POWER/COMMUNICATIONS PLAN SCALE: 1 /8" = V-70" i I o� NORTH 0 „\ FLAG NOTES VERIFY EXACT LOCATION OF POKE—THRU. WITH ARCHITECT PRIOR TO ROUGH —IN. VERIFY ELECTRICAL REQUIREMENTS WITH FURNITURE/EQUIPMENT VENDOR. 2� COORDINATE OUTLET LOCATIONS WITH INTERIOR DESIGNER. 3� VERIFY MOUNTING HEIGHT. GENERAL NOTES 1. OUTLETS SHOWN WITH LIGHT LINEWEIGHT ARE EXISTING TO REMAIN. MAINTAIN CIRCUIT & ACCURACY MARK ON AS—BUILTS. - REVIEW17 FOR COPLIANC NEC�H NFPA 7O MAR 17 2015 C'Ity of_Tu�vl►il��� RECEIVED CITY OF TUKWILA MAR. 0.9 2015 PERMIT CENTER N C � ti M N CD CC-4 CD U.)m rn cri d =0 Cl)d N IL a co,O L V N ti op O O F Q 0 R N C > ' •U C C' d v o C3 a' v o 0 o m o 00 �-' co m N N N qD y N to .--. Tca j Cn c 0- .0 0 o �. Z CnU O 1O CO O Lp LO CD O . I-- L0 creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS CASE - ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUEIREVISION PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6.2015 SHEET TITLE 1ST FLOOR POWER/ COMMUNICATIONS PLAN SHEET NO. © 2015 Cole+Russell Architects, Inc. /I—N I ` U)Z Z < IN Z U UW U= t_ U za 0 aW ccV) o� =W LL =0 FU Z° �-z zW wZ Z UU O F 00 = a. W� .0 z� w ~a =W a J co j W co- U W3 LL 0 00 OF �LL W n. 0 � o. a� in LL >U y W a %0 W N 13 M Q � G U 0 W W O2 0 N as � a W O L 2 LL H 0 m y W Z' v >O U W p oa k(A U O 2 W J r- m a NORTH 2ND FLOOR POWER/COMMUNICATIONS PLAN SCALE: 1 /8" = 1'-0" / FLAG NOTES VERIFY EXACT LOCATION OF POKE—THRU WITH ARCHITECT PRIOR TO ROUGH —IN. VERIFY ELECTRICAL REQUIREMENTS WITH FURNITURE/EQUIPMENT VENDOR. R:> COORDINATE OUTLET LOCATIONS WITH INTERIOR DESIGNER. [�>VERIFY MOUNTING HEIGHT. GENERAL NOTES 1. OUTLETS SHOWN WITH LIGHT LINEWEIGHT ARE EXISTING TO REMAIN. MAINTAIN CIRCUIT & ACCURACY MARK ON AS—BUILTS. 1 FIEV1EWED FOD COMPLIANCE WITH t4fP.A70 MAR 17 2015 a-fty Of Tuh _. a.. mikin n1V9SvQ RECEIVED CITY OF TUKWILA MAR• 0 9 2015 PERMIT CENTER co co o co � (0 N ei ti W Cq CO rn o p CDCq d N a °- N C O C) r• CO 0) co O ~ Q 0 (U9 N C C (D ( •U � U 0 � Cl) � o 0 0 o N C CO m > ca fII u d C CD O co Z Cn o ti o to coo r- LO f= z CO w > � K Z w a creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS Consulting Electrical Engineers 9515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone; 425-402-9400 Fax: 425-402-9402 ISSUE/REVISION PROJECT TITLE SE.CU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6,2015 SHEET TITLE 2ND FLOOR POWER/ COMMUNICATIONS PLAN SHEET NO. © 2015 Cole+Russell Architects, Inc. i B \} — cf)Z Z a� Z W 0 U= F- U ZQ OW W m � oW zW =o F- U U. 00 Z {- F Z Z W W N Z UU 0 F- C1U WJ F- a. X � F- lL F_ .0 z� �g W K Wa =W it Qa j W + U W 2 W Up 5 LL of �w W� n. 0 LLOa av LL >W �a F- �F- o U W 0 = 0 0 F- N aCC o W 0 L V F 0 `m U W Z� v 20 U oa W (A U 0 2 W W rm a 7 I 1 ! ' t PANEL PA1 PANEL PA4 I I \ter/ I i I ! PANEL PA1 PANEL PA4 I I I I I I 1 ST FLOOR LIGHTING PLAN SCALE: 1/8" = 1'-0" I I I ( 6 7) C FIEVIEVEC FOR CO PLJAN � EC H HpA70 I MAR 17 2015 City RECEIVED CITY OF TUKWILA MAR. 0 9 2015 PERMIT CENTER o co N O O co 1� C7 N ib M ti co O M O OO M 0 N O N tN NO O O � N r- a0 O O ~ Q ( O ca ?y m aS c 0 U C V 0 O N o O O N O COO N N in N Q) a)m C ._ N to M ... Co > co vco a m c o "> o � CD co o co Ln o to ti LO F- LU LU Cl)J V > 1- U 0 2§ creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUE/REVISION PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6,2015 SHEET TITLE 1ST FLOOR LIGHTING PLAN SHEET NO. E301 © 2015 Cole+Russell Architects, Inc. C. — — a �U fA Z Z ZW 0, ~U Z� OLU J co co LL W Z W W J x0 1-0 ix U- 00 Z F- F- Z W CO Z UU O F- 00 WWW FF W F- Z .0 U2 ZF N W� ~a =W � a as Nm F +_ + U O� LL LL 0 U W W a� 0: av > CJ 65 W a J CO XUW W F 0 F- o �W N 0 S 0 H N ajX o WO c F p m mW z W0 �o w UW p oa W 00 SW J rm a I r (5) 6') 7) GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL F, UNLESS OTHERWISE NOTED. ---- —---------- —.jam -� r,\ CONSULTANTS CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUE/REVISION REVIEWS E FOR H NFR MAR 1 � 2015 city 0 - e%i nm► I RECEIVED I UKwILA, WA 98188 CITY OF TUKWILA COMMISSION NO. 900515 MAR 0 9 2015 ISSUE DATE MARCH 6,2015 SHEET TITLE PERMIT CENTER 2ND FLOOR LIGHTING PLAN SHEET NO. E302 0 2015 Cole+Russell Architects, Inc. i co aN ~U Z W 0= H 0 Z Q O_j Z W W J =0 F 0 Of LL 00 Z �— Z W W to z 00 of-- 0 0 =a W� Z� 0 z� WC, ~a =W it IL QLL J j -Wri I co_ + U W = 0 0 O 0 OLL F W W� n. 0 Wa av WLL W �LL W Uj 0 In Z N Q � 7 W N � = O N a� o WO = = LL Ho l0 cn W z D m 0 c U W p 0 n. W � Q Fm a I `r i PANEL PA1 ` PANEL PA4 I ! PANEL PAII PANEL PA4 I I I I I L \2 I I I ('4,, 1 ST FLOOR EMERGENCY EGRESS CALCULATION SCALE: 1 /8" = 1'-0' Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min BANKING RM EMERGENCY EGRESS Illuminance Fc 2.96 4.6 1.1 2.69 4.18 BREAK RM EMERGENCY EGRESS Illuminance Fc 3.54 5.8 1.0 3.54 5.80 LENDING EMERGENCY EGRESS Floor Illuminance Fc 6.79 1 8.3 2.6 2.61 3.19 OPEN OFFICE EMERGENCY EGRESS Illuminance Fc 3.44 1 5.7 1 1.0 3.44 5.70 �DJ CbP�--� a NEC - �EE' ?J r`� J MAR 1 � 2015 of TulkwIlaatty t, RECEIVED CITY OF TUKWILA MAR. 0 9 2015 PERMIT CENTEci 00 ti Co 00 o "*: m N � O t6 cN iD ri co C6 Lo M M O d M d N a a 0 o H > o U C N V 0 C U) cz O 0 p 00 N N fn N N _N N d 7 � N y � N w N cc = a in as a c m_ U) '> ,n z o r.- o to o co Ln o to ti LO t= Z N � U > U O 0 creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS _ CASE - ENGINEERING Consulting Electrical Engineers. 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUE/REVISION PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6.2015 SHEET TITLE 1ST FLOOR LIGHTING PLAN SHEET NO. . EL401 © 2015 Cole+Russell Architects, Inc. n^1 C a � U N Z Z Cn �F- Z w 0 U= ~U Z 2 f J J LU CA o � =W W J IU -- 00 Z f- WZ V U O I- C U is �� Zn 0 zi- W LU ~a =w a. a J j w � - D= + U W 2 J 00 a a 0 I- �w W a. 0 0a aV III U- >W �a Z � N Z O Q O W 0O 8 N a0 0 W OLL L ~0 s m W Z� 2O �o m U W p oa w y 0 2 LLl J t- m a PANEL E PANEL F 1 � PANEL E I PANEL F I i i I ! i I i j C6 1 NORTH 2ND FLOOR EMERGENCY EGRESS CALCULATION SCALE: 1 /8" = V-0" Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min BOARD RM EMERGENCY EGRESS Illuminance Fc 4.44 9.0 1.2 3.70 7.50 OPEN OFFICE EMERGENCY EGRESS Illuminance Fc 4.42 5.9 1.2 3.68 4.92 i p�EV1�V®�� � Wt �� :. ® �'/ NG- WA70 NEC MAR 1 2015 �Illf- n►VIS1 ' .. RECEIVED CITY OF TUKWILA MAR. 0 9 2015 PERMIT CENTER CO CO C' c o N O M CD C6 N cli C'7 b CO G C+i rn o a-M tl N a a. No v � c � o o o ru U C (U U O .4 o o CD CD m CDN C -O N N N rn d Cn 'n a C O a O` CO U CD Cm Z rn O � O CO F- Z of Uj Lu Z Z Q U o 0 to C D co W W L creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUE/REVISION PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6,2015 SHEET TITLE 2ND FLOOR LIGHTING PLAN SHEET NO. EL402 © 2015 Cole+Russell Architects, Inc. 0 a zd rnz a U ZW 0, = U Z Oa F J J �LU U) 0� U) zW �0 00 Z F- z ZW W N UU O F- of) W j F X zo Z F=- c I-o WW �a =a U W a: ¢co w CCC_ U WS J 00 a LL r0 F W W' a0 Cfa o. v W L- -W m n. oZ Q xq c 0 N 0 N CL 0 K WO r 2a ca � m W z j v 20 U W p o a: WF to U ~O = W J rm a. NORTH PARTIAL BASEMENT ELECTRICAL PLAN xe. z /p. EXISTING RISER DIAGRAM. NOT TO SCALE SHORT CIRCUIT CALCULATIONS CIRCUIT DEFINITION CONDUCTOR CIRCUIT IMPEDANCE AVAILABLE MINIMUM DESCRPTION CONDUIT # IN OHMSIMFT OHMS FAULT PANEL LENGTH MATL SIZE PARALLEL R X R X Z CURRENT RATING AVAILABLE FAULT CURRENT @ SCL 300 kVA XFMR 0.00000 0.00216 0.00216 55,560 FEEDER TO 1200A BUSSED GUTTE 145 N 500 kCMIL CU 3 0.027 0.039 0.00131 0.00189 0.00229 (AIC SHOWN AT END OF FEEDER) 0.00131 0.00404 0.00425 28,234 FEEDER TO PANEL PD 15 M 250 kCMIL AL 2 0.086 0.052 0.00065 0.00039 0.00075 (AIC SHOWN AT END OF FEEDER) 0.00195 0.00443 0.00484 24,770 FEEDER TO PANEL PA1 DISC 5 M 250 kCMIL AL 1 0.086 0.052 0.00043 0.00026 0.00050 (AIC SHOWN AT END OF FEEDER) 0.00238 0.00469 0.00526 22,798 FEEDER TO PANEL PA1 80 M 3/0 CU 1 0.079 0.052 0.00632 0.00416 0.00757 (AIC SHOWN AT END OF FEEDER) 0.00870 0.00885 0.01241 9,667 FEEDER TO PANEL PA4 95 M 6 CU 1 0.490 0.064 0.04655 0.00608 0.04695 (AIC SHOWN AT END OF,FEEDER) 0.05525 0.01493 0.05723 2,097 FEEDER TO PANEL PA5 50 M 250 kCMIL AL 1 0.086 0.052 0.00430 0.00260 0:00502 (AIC SHOWN AT END OF FEEDER) 0.00625 0.00703 0.00941 12,752 FEEDER TO PANEL PA6 115 M 1 AL 1 .0.250 0.057 0.02875 0.00656 0.02949 (AIC SHOWN AT END OF FEEDER) 0.03500 0.01359 0.03755 3,196 FEEDER TO PANEL B DISC 5 M 310 CU 1 0.079 0.052 0.00040 0.00026 0,00047 (AIC SHOWN AT END OF FEEDER) 0.00170 0.00430 0.00463 25,927 FEEDER TO PANEL B 90 M NO CU1 0.079 0.052 0.00711 0.00468 0.00851 (AIC SHOWN AT END OF FEEDER) 0.00881 0.00898 0.01258 9,536 FEEDER TO PANEL F 95 M 3 CU 1 0.250 0.059 0.02375 0.00561 0.02440 (AIC SHOWN AT END OF FEEDER) 0.03256 0.01459 0.03568 3,363 NOTES TO CALCULATIONS: 1. CALCULATIONS ARE BASED ON OHMIC METHOD, 120 VOLTS LINE TO GROUND FAULT. 2. CONDUCTOR IMPEDANCE IS BASED ON NATIONAL ELECTRICAL CODE TABLE 9. 3. CONDUIT MATERIAL: M=MAG, N=NON-MAG SOLID SHADING IN HEAVY LINES INDICATES NEW WORK IN THIS CONTRACT. 32,500 AVAILABLE FAULT CURRENT (IN AMPS) LOAD SUMMARY 1200 AMP BUSSED GUTTER 480Yt277V, 3-PHASE, 4-WIRE CONNECTED DEMAND DEMAND LOAD DESCRIPTION I LOAD-kVA FACTOR kVA AMPS EXISTING LOAD MAX DEMAND PER SCL METER (95.6 kW @ 0.95 PF) ADDITIONAL LOAD (PANEL PA4): RECEPTACLES - GENERAL USE** HEATING MOTORS LIGHTING KITCHEN OTHER )ITIONAL LOAD. (PANEL PA5): RECEPTACLES - GENERAL USE** HEATING MOTORS LIGHTING KITCHEN OTHER )ITIONAL LOAD (PANEL F): RECEPTACLES - GENERAL USE** HEATING MOTORS LIGHTING KITCHEN OTHER AL - 1200A BUSSED GUTTER 100.6 1 1.25 1 125.8 1 349 1.8 1.8 5 0.0 1.00 0.0 0 0.0 1.00 0.0 0 1.8 1.25 2.3 6 0.0 0.65 0.0 0 3.9 1.00 3.9 11 6.4 6.4 18 31.4 1.00 31.4 87 0.0 1.00 0.0 0 .0.0 1.25 0.0 0 0.0 0.65 0.0 0 223 1.00 22.3 62 6.3 * 6.3 18 0.0' 1.00 0.0 0 0.1' 1.00 0.1 0 5.5 1.25 6.9 19 0.0 065 0.0 0 19.8 1.00 19.8 55 199.9 226.9 630 *50% DEMAND ON GENERAL USE RECEPTACLES OVER 10 kVA "DOES NOT INCLUDE RECEPTACLES FOR SPECIFIC EQUIPMENT @ 208Y/120V 3PH, 4W REVIEWEDGWPLIAN�FOR t` tIFPA70 MAR 1 � 2015 k city ��ntila G� gUILDIN� DIVISION - RECEIVED CITY OF TUKWILA MAR. 0 9 2015 PERMIT CENTER CD LO 00 o co cn N O LO O M N m M Cq 04 CR p co O- 11 a a 0 N N C U > C d o 0 o a� o 0 0 N N N N � N � N >+ ca CO > N 3 M5 Q N A d m o C `O U L CD Z W o r- O CO O p O CD(� � � creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSUE/REVISION PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6,2015 SHEET TITLE RISER DIAGRAM SHEET NO. E801 © 2015 Cole+Russell Architects, Inc. III a 2U Cl) Z Z- a� ~U z LL O U= F- U ZOf 0¢ L_ J J W co K U_ v ZW _0 �LL 00 Z I_ WZ UU O 1- 00 =a z M z= Wa =a UW as m J W X_ + U W 2 J Up 0 Ly � U W a � �a n. v W LL >U V5 W >a CO co oz a�0 F � o U a n 00 F N as 0 0 K WO t U. �a fA W U, Op � UW p oa W UU 0 2 W J t- m a NEW PANEL: PA6 PROJECT NAME SECU PROJECT#: 15055 LOCATION: IT ROOM 130 FED FROM: PANEL PA5 NOTE CKT NO. CIRCUIT NAME CB SIZE LOAD (KVA) PANEL DESCRIPTION 0AMPP R H M L K O TOTAL 1 REC- BREAK ROOM 125 A 20 1 0.2 I 0.5 0.7 PANEL AMPS : 100 3 RED- BREAK ROOM 125 B 20 1 0.4 0.4 FEEDERAMPS : 100 5 REC- BREAK ROOM 125 ISLAND C 20 1 1.0 1.0 L - L VOLTS : 208 7 DISHWASHER A 20 1 ! 1.2 1.2 L - N VOLTS : 120 9 COFFEE B 20 1 1.5 1.5 PHASE: 3 11 DISPOSAL C 20 1 0.2 0.8 1.0 WRE : 4 13 ICEMAKER A 20 1 1.1 1.1 AIC : 10kA 15 REFRIGERTOR B 20 1 ! 1.1 1.1 17 REFRIGERTOR C 20 1 I 1.1 1.1 M.L0. )C 19 REC- SERVER 130 Al2011 i 1.5 1.5 1 21 REC- SERVER 130 B 20 1 1.5 1.5 MAIN CB 23 REC- SERVER 130 C 20 1 1.5 1.5 FLUSH 25 SPARE A 20 1 SURFACE X 27 SPARE B 20 1 ISO GND 29 SPARE C 20 1 FEED-TFRU 31 SPACE A 33 SPACE B 35 SPACE C 37 SPACE A LOAD SUMMARY 39 SPACE B ITO TAL.ALL SECTIONS 1 41 SPACE C REC KVA : 2.2 2 REC- BREAK ROOM 125 A 20 1 0.6 1 0.6 4 REC - LOUNGE 126 B 20 1 0.8 0.5 1.3 HEAT KVA : 14.6 MOTOR KVA : 6 EWH-2 C 50 2 4.2 4.2 8 - A - - 4.2 4.2 LIGHTING KVA 10 EWH-3 B 40 2 3.1 3.1 KITCHEN KVA OTHER KVA : 13.3 12 - C - - 3.1 3.1 14 SPARE A 20 1 16 SPARE B 20 1 PHASEA KVA : 9.3 18 SPARE C 20 1 AMPS : 77.5 20 SPARE A 20 1 PHASE B KVA : 8.9 22 SPARE B 20 1 AMPS : 74.2 24 SPARE C 20 1 PHASECKVA : 11.9 26 SPARE A 20 1 AMPS : 99-2 28 SPARE B 20 1 30 SPACE. G 32 SPACE A CONNECTEDLOAD 34 SPACE B KVA : 30.1 36 SPACE C AMPS : 83.5 38 SPACE A DEMA ND LOA D 4d SPACE B KVA : 30.1 42 1 SPACE C AMPS : 83.5 NOTESIREMARKS : 1. 2. 3. DEMANDI CIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 2.2 REMAINING OVER 10KVA 50% _ H HEATING 100% = 14-6 M MOTORS 100% _ LM LARGESTMOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% = 0 OTHER 100% _ 13.3 NEW PANEL: F PROJECT NAME SECU PROJECT # 15055 LOCATION: IT ROOM 290 FED FROM PANEL B NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 AMP P R H M L K 0 TOTAL 1 REC - CONFERENCE 200 A 20 1 1.0 1.0 PANEL AMPS : 100 3 REC - CONFERENCE 241 B 20 1 0.6 0.6 FEEDER AMPS : 100 L - L V OLTS : 208 L - N VOLTS : 120 PHASE: 3 5 REC - OFFICE 240 C 20 1 0.2 0.3 0.5 11 7 REC - OFFICE 240 A 20 1 1 0.9 0.9 9 REC - OFFICE 240 B 20 1 0.9 0.9 11 REC - OFFICE 245 C 20 1 0.9 0.9 WIRE : 4 13 REC - CONFERENCE 242 A 20 1 0.9 0.9 AIC : 10kA 15 REC - OFFICE 245 B 20 1 0.8 0.8 17 REC - OFFICE 246 G 20 1 1 0.6 0.6 19 REC - OFFICE 246 A 20 1 0.9 0.9 M L.O. MAIN CB FLUSH X 21 REC - OFFICE 246 B 20 1 0.9 0.9 23 REC - OFFICE 246 C 20 1 0.6 0.6 25 REC - OFFICE 246 A 20 1 0.9 0.9 SURFACE X 27 REG - OFFICE 246 B 20 1 0.9 0.9 ISO GND 29 REC -OFFICE 246 1 1.2 1.2 FEED THRU 31 REC - OFFICE 246 1 0.6 0.6 33 REC - OFFICE 246 1 0.9 0.9 35 LTS - CONFERENCE ROOM 41A 1 1.2 1.2 37 SPACE LOADSUMMARY 39 SPACE ITO TAL,ALL SECTIONS 1 41 SPACE REC KVA : 6.3 2 LTS - SECU 2ND FLOOR A 20 1 1.3 1.3 4 LTS - SECU 2ND FLOOR B 20 1 1.3 1.3 HEAT KVA MOTOR KVA : 0.1 LIGHTING KVA : 5.5 6 LTS - SECU 2ND FLOOR C 20 1 1.0 1.0 8 LTS - SECU 2ND FLOOR A 20 1 0.7 0.7 10 REC - OFFICE 240 B 20 1 0.9 0.9 KITCHEN KVA 12 REC - OFFICE 240 C 20 1 0.9 0.9 OTHER KVA : 19.8 14 REC - WORKROOM 243 A 20 1 0.8 0.8 PHASEA KVA : 11.3' 16 REC - OFFICE 240 B 20 1 0.6 0.6 18 REC-MAIL ROOM244 C 20 1 0.6 0.6 AMPS : 94.2 20 REC- SERVER 290 A 20 1 1.5 1.5 PHASE B KVA : 10.1 22 REC - SERVER 290 B 20 1 1.5 1.5 AMPS : 84.2 24 REC - SERVER 290 C 20 1 1.5 1.5 PHASE C KVA : 10.3 26 REC - OFFICE 240 A 20 1 0.9 0.9 AMPS : 85.8 28 REC - OFFICE 245 B 20 1 0.6 0.6 30 REC - OFFICE 247 C 20 1 1.2 1.2 32 REC - OFFICE 246 A 20 1 0.9 0.9 CONNECTED LOAD 34 RED -CONFERENCE ROOM: B 1 2011 0.2 1 1 0.2 KVA : 31.7 36 EF 1 C 20 1 0.1 0.1 AMPS.: 88.0 38 SPACE A DEMAND LOAD 40 SPACE B KVA ; 33.1 42 SPACE C AMPS : 91.9 NOTES/REMARKS: 1. 2. 3. D6UTANDI DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R. RECEPTACLES -TO10KVA 100% = 6.3 REMAININGOVER 10KVA 50% = H HEATING. 1000% _ M MOTORS 100%. - LM LARGESTMOTOR 1256/o _ 0.1 L LIGHTING 125% = 6.9 K KITCHEN 65% _ O OTHER 100% = 19.8 NEW PANEL: PA5 PROJECT NAME SECU PROJECT r#: 15055 LOCATION: SUPPLIES 105 FED FROM: PANELPD NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANE. DESCRIPTION 8 AM P P R H PM L K 0 TOTAL 1 REC - OFFICE 103 A 20 1 0.9 0.9 PANEL AMPS : 200 3 REC - OFFICE 103 B 20 1 0.9 0.9 FEEDER A MPS : 200 5 REC - OFFICE 103 C 20 1 0.9 0.9 L - L VOLTS : 208 7 REC - OFFICE 103 A 20 1 0.6 0.6 L - N VOLTS : 120 9 REC- OFFICE 103 B 20 1 1.2 1.2 PHASE: 3 11 REC - OFFICE 1011 102 C 20 1 1.2 1.2 WIRE : 4 13 REC- CONFERENCE ROOM FLOORBOX A 20 1 0.2 0.2 AIC: 22kA 15 SPA RE B 20 1 17 SPARE C 20 1 19 SPARE Al20,1 M.L.O. MAIN CB X 21 SPARE B 20 1 I 23 SPARE C 20 1 FLUSH 25 SPARE A 20 1 SURFACE X 27 SPARE B 20 1 ISO GND 29 SPARE C 20,1 FEED-THRU 31 SPACE A 20 1 33 SPACE B 35 SPACE C 37 SPACE A LOADSUMMARY 39 SPACE B I L TOT AL. A L L S E C T IO N SI 41 SPACE C REC KVA : 6.4 2 REC- CONFERENCE 104 A 20 1 0.8 0.8 4 REC- WORKROOM 105 B 20 1 1-0 1.0 HEAT KVA : 31.4 MOTOR KVA 6 REC - KITCHEN 106 C 20 1 1.5 1.5 8 REC- KITCHEN 106 A 20 1 I 1.5 1.5 LIGHTING KVA 10 REC - BA LACING 100 B 20 1 0.4 I I 0.4 KITCHEN KVA 12 REC- BANKING 100 RECEPTION DESK C 20 1 0.2 0.2 OTHER KVA : 223 14 REC- BANKING100 FLOOR BOXES A 20 1 0.4 0.4 16 REG- BANKING 100 ATM B 20 11 10.5 0.5 PHASEA KVA : 22.1 AMPS : 184.2 18 REC- BANKING 100 ATM C 2011 I I 1.0 1.0 20 EWH-1 A 50 2 4.2 4.2 PHASE B KVA ': 17.1 22 - B - - 1 4.21 4.2 A MPS : 142.5 PHASE C KVA : 20.9 24 EWH-4 C 50 21 1 42 4.2 26 - A - - I 4.2 4.2 A MPS _ 174.2 28 SPARE B 20 1 30 SPARE C 20 1 32 SPACE A CONNECTED LOAD 34 SPACE B KVA : 60.1 36 SPACE C AMPS : 166.8 38 SUBFEED- PANEL PA6 A 100 3 0.8 4-2 4.3 9.3 DEMAND LOAD 40 - B - - 1.2 3.1 4.6 8.9 KVA : 60.1 42 - C - -1 0.2 1 7.3 4.4 11.91 A MPS : 166.8 NOTESIREMARKS : 1. 2. 3. DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES -TO 10KVA 100% = 6.4 REMAINING OVER 10KVA 50% _ H HEATING 100% = 31.4 M MOTORS 100% _ LM LARGESTMOTOR 125% _ L LIGHTING 125% K KITCHEN 65% = O OTHER 100% = 22.3 PROJECT-s LOCATION: 2ND FLOOR ELECTRICAL ROOM FEDFROM PANEL B W_ MMMM=I=�M- • 1: ■■© • ©WSMMMMMM■ ■■■ ■■■■■■■■■■■ ■■ ■■■■■■■■■■ ■■ ■■■■■■■■■■ MAIN CB ■■■ ■■■�■■■■■■■�■ FLUSH■ ■■■■ ■■■i■■■■■■■■■ _ISO GNID ■■ ■■�■■■■■■■_ • ■ SUMMARY mm (TO TAL. ALL SECTIONS I REC KVA : 1.0 =='WA MORTGAGE COMPUTER -Q Q■��■■■�� H • • •- LIGHTING KVA : 3.5 ■Q Q■■�■■■■�� ■� Q■�■■■■-��KITCHEN KVA OTHER KVA 4.8 PHASE A KVA 33 R-ASE B KVA 3.3 ■■ 1M■ - . ■■ m■ ■■■■■■■■■■ AMPS 25.8 ■■ ■■■ ■■_---- KVA 4 1 ■■ I NOTESIREMARKS: NO NEW WORK• •- REFERENCE ONLY 2. DEMAND/ DIVERSITY FACTORS •• s DESCRIPTION RECEPTACLES - T• 10KVA 100%iff- REMAININGOVER 1 /, /- MOTORS 100% LM LARGEST MOTOR 125% L LIGHTING 125% 4.4 K KrT• - 0 OTHER 100% 4.8 NEW PANEL: PA4 PROJECT NAME SECU PROJECT#: 15055 LOCATION: IT ROOM 130 FED FROM PANEL PA NOTE CKT NO. CIRCUIT NAME CB SIZE LOAD(KVA) PANEL DESCRIPTION elAMP P R H M L K 0 TOTAL 1 REC- OFFICE 110 A 20 1 0.8 0.8 PANEL AMPS : 60 3 REC - OFFICE 110 B 20 1 0.6 0.6 FE®ER A M?S : 60 5 REC - OFFICE 110 C 20 1 1.2 1.2 L- L VOLTS : 208 L - N VOLTS. 120 7 REC - OFFICE 110 A 20 1 0.9 0.9 9 REC- OFFICE 110 B 20 1 0.9 0.9 PHASE : 3 11 REC- OFFICE 110 C 20 1 0.2 0.2 WIRE: 4 13 REC - OFFICE 110 A 20 1 0.6 0.6 AIC : 10kA 15 REC - OFFICE 110 B 20 1 0.3 0.3 17 SPARE C 20 1 19 SPARE A 20 1 M.L.O. MAIN CS X 21 ISPARE B 20 1 23 SPARE C 20 1 FLUSH 25 SPACE A SURFACE X 27 SPACE B ISO GND 29 SPACE C FEED-Tf RU LOAD SUMMARY I TOTAL. ALL SECTIONS I REC KVA : 1.8 2 LTS - SECU 1ST FLOOR A 20 1 1.0 1.0 4 LTS - SECU 1ST FLOOR B 20 1 0.6 1 0.6 HEAT KVA MOTOR KVA 6 LTS - SECU 1ST FLOOR C 20 1 0.2 0.2 8 SPARE A 20 1 LIGHTING KVA : 1.8 10 REG - OFFICE 110 FLOORBOX B 20 1 0.2 0.2 KITCHEN KVA 12 SPARE C 20 1 OTHER KVA : 3-9 14 SPARE A 20 1 16 SPARE B 20 1 PHASEA KVA : 3.3 AMPS : 27.5 18 SPARE C 20 1 20 SPARE A 20 1 PHASE B KVA : 2.6 22 SPARE B 20 1 AMPS : 21-7 24 SPARE C .20 1 PHASECKVA : 1.6 26 SPACE A AMPS : 13.3 28 SPACE B 30 SPACE C CONNECTED LOAD KVA : 7.5 AMPS : 20.8 DEMAND LOAD KVA : 8.0 A MPS : 22.1 NOTES/REMARKS: 1. 2. 3. DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES-TOIOKVA 100% = 1.8 REMAINING OVER 10KVA 50% _ H HEATING 100% _ M MOTORS 100% _ LM LARGEST MOTOR 1256% _ L LIGHTING 125% = 2.3 K KITCHEN 65% _ 0 OTHER 100% = 3.9 EXISTING PANEL: B PROJECT NAME SECU PROJECT#: 15055 LOCATION: 2ND FLOOR ELECTRICAL ROOM FED FROM 1200A BUSSED GUTTER NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD (KVA) PANEL DESCRIPTION 8 A P R H M L K 0 TOTAL 1 RED -OFFICE A 20 1 1.0 1.0 PANELAMPS : 200 3 REC - OFFICE B 20 1 1.2 1.2 FEEDER A NIPS : 200 L- L VOLTS : 208 L - N VOLTS : 120 PHASE: 3 5 REC- OFFICE C 20 1 0.8 08 7 LTS - WA MORTGAGE A 20 1 1.1 1.1 9 LTS - WA MORTGAGE B 20 1 0.6 0.6 11 LTS - WA MORTGAGE C 20 1 1 0.7 0.7 WIRE: 4 13 LTS - WA MORTGAGE A 20 1 0.9 0.9 15 LTS - WA MORTGAGE B 20 1 0.4 0.4 17 REC - WA MORTGAGE C 20 1 0.8 0.8 19 REC-WA MORTGAGE A 20 1 0.6 0.6 MLO. MAIN CB FLUSH X 21 REC - WA MORTGAGE B 20 11 0.6 0.6 23 REC- WA MORTGAGE C 20 11 1.0 1-0 25 LTS - 230 A 20 11 0.8 0.8 SURFACE X 27 LTS - 230 B 20 11, 0.7 0.7 ISO GND 29 REC - HALL C 20 Ill 0.4 0.4 FEED-THRU 31 RIB; - WA MORTGAGE A 20 1 1.0 1.0 33 REC- WA MORTGAGE B 20 1 0.8 0.8 35 REC- SUPPLY ROOM C 20 1 0.4 0.4 37 REC-SUPPLY ROOM A 20 1 0.4 0.4 LOADSUMMARY 39 REC - TENA NT OFFICES B 20 1 1.0 1.0 (TOTAL . A L L S E C T I O N s I 41 REC- TENANT OFFICES C 20 1 .1.2 1.2 REC KVA : 21.3 2 REC - OFFICES A 20 1 0.4 0.4 4 REC - OFFICES B 20 1 0.6 0.6 HEAT KVA : MOTOR KVA : 3.8 6 REC - INTERNATIONAL SHIP C 20 11 0.8 0.8 8 LTS - RESTROOM A 20 1 0.5 0.5 LIGHTING KVA : 16-0 10 LTS - OUTDOOR SOFFIT B 20 1 0.9 0.9 KITCHEN KVA 12 LTS - LOBBY C 20 1 0.4 0.4 OTHER KVA : 25.5 14 WATER COOLER A 20 1 0.6 0.6 16 REC- PHONES B 20 1 0.2 0.2 PHASE A KVA : 23.7 AMPS : 197.5 18 RESTROOM EXHAUST FANS C 15 0.7 0.7 1 20 SUBFEED- PANEL F A 100 #32�. 2.0 6.6 11.3 PHASE B KVA : 21.3 22 - B - 1.3 7.2 10.1 ANDS : 177.5 24 - C - - 2.0 0.1 2.2 6.0 10.3 PHASECKVA : 21.6 26 SPRRINKLERCOMPRESSOR A 15 3 0.8 0-8 AMPS : 180.0 28 - B I - - 0.8 0.8 30 - Cl- - 0.8 0.8 32 REC-OFFICES A 1 20.1 10 1.0 CONNECTED LOAD 34 LTG CONTROL BI 20 11 0.1 0.1 KVA : 66.6 36 REC-OPEN OFFICE C 20 1 0.6 0.6 AMPS : 184.9 38 SUBFEED-: PANEL D A 70 3 1.1 2.2 3.3 DEMAND LOAD 40 - B - - 0.6 0.9 1.8 3.3 KVA AMPS : 180.8 42 - C - -1 0.4 1.5 1 0.8 2.7 NOTFFSIREMARKS : 1. PROVIDE NEW EREAKERAS SHOWN. REPLACEEXTG SPARE RELOCATE CIRCUITSIFREQUIRE3. 2. 3. DEMAND DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES -TO 1 0KVA 100% = 10.0 REMAININGOVER.10KVA 50% = 5.7 H HEATING 100% = MMOTORS 100% = 3.0 LM LARGEST MOTOR 125% = 1.0 L LIGHTING 125% = 20.0 K KITCHEN 65% _ 0 OTHER 100% = 25.5 EXISTING PANEL: PA1 PROJECT NAME: SECU PROJECT It 15055 LOCATION: 1 ST FLOOR ELECTRICAL ROOM FED FROM: PANEL PD NOTECKT NO. CIRCUTNAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 AMP P R H M L K O 1 TOTAL 1 REC - TTB A 20 1 0.2 0.2 PANEL AMPS : 200 3 COPY MACHINE B 20 1 i 1.2 1.2 FEEDERAMPS : 200 5 COFFEE C 20 1 1.0 To L - L VOLTS : 208 L - N V OLTS : 120 7 REC - OFFICE A 20 1 0.6 I 0.6 9 LTS - CLASSROOM B 20 1 0.5 0.5 PHASE : 3 11 REC - OFFICE C 20 1 0.8 0.8 WIRE : 4 13 REC - DOW A 20 1 1.0 1.0 15 REC - DOW B 20 1 0.6 0.6 17 REC - DOW C 20 11 0.6 0.6 19 REC - TA 18 A 20 1 0.8 0.8 M L.O- MA IN CB X 21 REC - TA 18 B 20 1 1.2 1.2 23 REC - TA 18 C 20 1 0.6 0.6 FLUSH 25 REC-PRIVATE OFFICES A 20 1 0.8 0.8 SURFACE X 27 REC - PRVATE OFFICES B 20 1 0.6 0.6 ISO GND 29 REC-PRIVATE OFFICES C 20 1 0.6 0.6 FEED-THRU 31 REC- PRIVATE OFFICES A 20 1 0.4 0.4 33 REC- PRIVATE OFFICES B 20 1 0.8 0.3 35 RED- PRIVATE OFFICES C 20 1 0.6 0.6 37 FLOAT SWITCH A 2011 1 0.1 1 0.1 1 LOADSUMMARY 39 HEAT- SPRINKLER ROOM B 20 2 1.0 1.0 ITO TA L. ALL SECTIONS ] 41 - C - - 1.0 1.0 REC KVA : 18.4 2 REC - OFFICES A 20 1 0.6 0.6 4 REC - OFFICES B 20 1 0.8 0.8 FEAT KVA : 26.0 MOTORKVA 6 REC-OFFICES C 20 1 0.8 0.8 8 WATER HEATER A 100 3 8.0 8-0 LIGHTING KVA : 2.3 10 - B - - 8.0 8.0 KITCHEN KVA 12 - C - - 8.0 8.0 OTHER KVA : 8.8 14 REC-PRIVATE OFFICES A 20 1 1.2 1.2 16 REC- PRIVATE OFFICES. B 20 1 1.0 1.0 PHASEA KVA : 18.0 ANPS : 150.0 18 REC- PRIVATE OFFICES C 20 1 0.6 0.6 20 REC- PRIVATE OFFICES A 20 1 0.6 0.6 PHASE KVA : 20.0 22 REC - DEDICATED B 20 1 0.8 0.8 AMPS : 166.7 24 REC - FLOOR PLUGS C 20 1 0.4 0.4 PHASE C KVA : 17.5 26 REC- FLOOR PLUGS A 20 1 0.4 0.4 AMPS : 145.8 28 REC - OPEN OFFICE B 20 1 0.9 0.9 30 REC - OPEN OFFICE C 20 1 0.9 0.9 1 32 SUBFEED- PANEL PA4 A 60 3 1.4 1.0 0.9 3.3 CONNECTED LOAD 34 - B - - 0.2 0.6 1.8 2.6 KVA : 55.5 AMPS : 154.1 36 - C - - 0.2 0 22 1.2 1.6 38 SPARE A 20 1 DEMAND LOAD 40 ISPARE B 20 1 KVA : 51.9 42 SPARE C 20 1 1 1 1 AMPS : 144.0 NOTESIREMARKS : 1. PROVIDENEWBRE4KERASSHOWN. REPLACEEXTG SPARE RELOCATECIRCUTSIFREQUIRED. 2. 3. DEMAND / DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES -TO10KVA 100% = 10.0 REMAINING OVER 10KVA 50% = 4.2 H HEATING 100% = 26.0 M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% = 2.9 K KITCHEN 65% _ 0 OTHER 100% = 8.8 NEW PANEL: PD PROJECT NAME: SECU PROJECT#: 15055` LOCATION: BASEMENT MAIN ELECTRICAL ROOM FED FROM: 1200A BUSSED GUTTER NOTE C NO. CIRCUTNAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 AMP P R H M L K 0 TOTAL 1 SUBFEED-PANELPA1 A 200 3 8.0 8.0 1A 1.0 18.0 PANFIAMPS : 400 3 - B - - 5.2 9.0 1.1 4.7 20.0 FEEDERAMPS : 400 L - L VOLTS : 208 5 - C - - 5.2 9.0 0.2 3.1 17.5 7 SPACE A- 3 L- N VOLTS : 120 9 - B - - PHASE : 3 11 - C - - WIRE: 4 13 SPACE A - 3 AIC : 42kA 15 - B - - 17- MLA- MAIN CB X FLUSH SURFACE X ISO GND FEEaTHRRU LOADSUMMARY (TOTAL.ALL SECTIONS ] REC KVA : 24.8 HEAT KVA : 57.4 MOTOR KVA 2 PANEL PA5 A 200 3 2.2 12.6 7.3 22.1 4 - B - - 2.6 7.3 7.2 17.1 6 - C - - 1 1.6 11-5 7.8 20.9 8 SPACE A - 3 LIGHTING KVA : 2-3 10 - B - I - I KITCHEN KVA 12 - C - - OTHER KVA : 31.1 14 SPACE A - 13 I PHASEA KVA : 40.1 AMPS : 334.2 16 - B - - 18 - C - - PHASE 8 KVA : 37-1 I AMPS : 309.2 PHASE C KVA : 38.4 AMPS : 320.0 CONNECTED LOAD KVA : 116.6 AMPS : 320.9 DEMAND LOAD KVA : 108.8 AMPS : 301.9 NOTESIREMARKS : 1. 2 3. DEMAND I DIVERSITY FACTORS LOAD DESCRIPTION' DEMAND R RECEPTACLES - TO 10KVA 100% = 10.0 REMAINING OVER 10KVA 50% = 7.4 H HEATING 100% = 57.4 M MOTORS 100%0 = LM LARGEST MOTOR 125% = L LIGHTING 125% _ 2.9 K KITCHEN 65% = 0 OTHER. 100% 31.1 FOR W1MPUA Y NfFPXt7 f MAR 1 � 2015Ow RECEIVED CITY OF TUKWIL A MAR. 0 9 2015 PERMIT CENTER om, o v co C'iN CO o co to N M 00 ti IR U') cri rn CM a M a N a °- CD N N LO ,n o V N n m o 0ca a 1= > U o cu � <J ) C) U) Cn 0 CDm o 0 o N N N N a) a) N N ? cn > m Cn v.a c cas 8 2in Lz cn o I� o to o cc u� o '.0 � H (n J > g KK Z w U 0 0 to creating extraordinary spaces www.cr-architects.com 800.469.4949 CONSULTANTS � CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 ISSU&REVISION PROJECT TITLE SECU TENANT IMPROVEMENT 5200 SOUTHCENTER BLVD . TUKWILA, WA 98188 COMMISSION NO. 900515 ISSUE DATE MARCH 6,2015 SHEET TITLE PANELSCHEDULES SHEET NO. . E901 © 2015 Cole+Russell Architects, Inc.