Loading...
HomeMy WebLinkAboutPermit EL15-0224 - VERIZON WIRELESS / ROOFTOP - ELECTRICAL SERVICE, FEEDERS AND WIRINGVERIZON WIRELESS - ROOFTOP 16400 SOUTHCENTER PKWY EL15-0224 City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL OTC PERMIT Parcel No: 2623049021 Permit Number: EL15-0224 Address: 16400 SOUTHCENTER PKWY BLDG Issue Date: 3/11/2015 Permit Expires On: 9/7/2015 Project Name: VERIZON WIRELESS - ROOTOP Owner: Name: LEGACY PARTNERS COMMERCIAL Address: PO BOX 130639, CARLSBAD, wa, 92013 Contact Person: Name: ERIC DILORETO Phone: (253) 720-8569 Address: 10820 150 ST E , PUYallup, wa, 98374 Contractor: Name: SINE WAVE ELECTRIC INC Phone: (253) 770-9283 Address: 10820 150TH ST E , PUYALLUP, WA, 98374 License No: SINEWWE922JQ Expiration Date: Lender: Name: Address: DESCRIPTION OF WORK: PROVIDE 100 AMP 480 VOLT SERVICE FOR VERIAON WIRELESS. PROVIDE NEW 480 VOLT SINGLE PHASE FEEDER FROM NEW SERVICE IN FIRST FLOOR ELECTRICAL ROOM TO THE FIFTH FLOOR ELECTRICAL ROOM. TIE INTO EXISTING FEEDER (SETJ-BOX) IN THE FIFTH FLOOR ELECTRICAL ROOM. DISCONNECT EXISTING FEEDER CONDUIT AND WIRE FROM PANEL ON THE FIFTH FLOOR THAT IS CURRENTLY FEEDING THE CELLSITE. Valuation of single family: $0.00 Fees Collected: $659.73 Valuation of mf/comm: $13,875.00 Type of Work: SERV CHNG Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: " A- `s Date:��` -4 5— I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: L`10'� Date: ll l Zb 1 Print Name: ie7C IL \ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department ' Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hqp://www.Tukwi[aWA.gov SITE LOCATION Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" King Co Assessor's Tax No.: Site Address: 16400 Southcenter Parkway Suite Number: ROOF Floor: 1-R00f Tenant Name: Verizon Wireless New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: Legacy Partners I Tukwila Address: 10655 NE 4th ST Suite 812 City: Bellevue State: WA Zip: 98004 CONTACT PERSON — person receiving all project communication Name: Eric DiLoreto Sine Wave Electric, Inc. Address: 10820 150th ST E City: Puyallup State: WA Zip: 98374 Phone: (253) 720-8569 Fax: Email: ELECTRICAL CONTRACTOR INFORMATION Company Name: Sine Wave Electric, Inc. Address: 10820 150th ST E City: Puyallup State: WA Zip: 98374 Phone: (253) 720-8569 Fax: Contr Reg No.: sinewwe922jq Exp Date: 04/18/2015 Tukwila Business License No.; BUS-0993749 Valuation of Project (contractor's bid price): $ 13,875 Scope of Work (please provide detailed information): Provide 100-amp 480-V service for Verizon Wireless. Provide new 480-V 1PH feeder from new service in 1st floor electrical room to the 5th floor electrical room. Tie into existing feeder (set j-box)in the 5th floor electrical room. Disconnect existing feeder conduit and wire from panel on the 5th floor that is currently feeding the cellsite Will service be altered? 91 Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Commerical Already spoke with Jim Benner Tvne of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served bv: Puget Sound Energy ❑ Seattle City Light H:Wpplications\Forms-Applimtions On Line\2014 ApplicationsTlectrical Permit Application Revised 1-1-14.dom Revised: January 2014 bn Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings...................................$152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals .................................... .... ....... ......... - .... ..—$80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name Eric M. DiLoreto Mailing Address I OR20 150th ST E Date: 03/10/2015 Day Telephone: (253) 72U-8569 Puyallup City WA 98374 HAApplicatiom\Forms-Applications on Lind2014 Applications\Electrical Permit Application Revised Id-14.docx Revised: January 2014 bh Page 2 of 2 DESCRIPTIONS ACCOUNTQUANTITY PermitTRAK PAID $659.73 EL15-0224 Address: 16400 SOUTHCENTER PKWY BLDG Apn: 2623049021 $659.73 DEVELOPMENT $300.00 PERMIT REINSPECT FEE - AFTER HRS INSP FEE R000.322.800.00.00 0.00 $300.00 ELECTRICAL $342.60 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $342.60 TECHNOLOGY FEE $17.13 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTALPAID BY RECEIPT:' . $17.13 $659.73 Date Paid: Wednesday, March 11, 2015 Paid By: ERIC DILORETOSINE WAVE ELECTRI Pay Method: CREDIT CARD 076659 Printed: Wednesday, March 11, 2015 9:19 AM 1 Of 1 "j�[!, �J' 1SY57EM5 INSPECTION RECORD L 2, JRetain a copy with permit �''�. ---, I INSPECTION NO. PERMIT NO. 1 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inslapction Request Line (206) 438-9350 Project, Type ofinspection- 4 ate Called: Special Instructions: Date Wanted. a.m. Request r: Phone No: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Catt to schedule reinspection, INSPECTION RECORD 6� 9 Retain a copy with permit I INSPECTION NO, PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit lnsppction Request Line (206) 438-9350 Project: V, Type of Inspection: Address: IHOO Date Called: Special Instructions'. o L Date Wantea: 3 Requester'. 7 - I FRone No: 3 '16 7 F. z Approved per applicable codes. Corrections required prior to approval. COMMENTS. rZ Inspector. e 1 Date: AI ��Zz --o 4 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • OFF HOURS INSPECTION • Reimbursement authorization/approval to conduct inspection activities during off hours. Date: _%j Zo ke Permit Number: — V� Requested By: Ec' tc , Lc--, C� Firm/Company: Inspection Information Project Name: VaP-lam rim cots-AQ-Iat> M IkCL P-, Project Address/Location: goz/o U Requested Date for Inspection: 3/Z2 2-0 5 Requested Time: AM / PM Contact Name: ��Z,,c- l c Phone Number: 253 7� - S S !o Special Conditions for Consideration: !"�'��c- �`j�'� "'��►�� -hoc vv\�t So we W L \k }'�s -Vo I 15� fOGEM 11MOFTOKWILA "Contractor will be charged a minimum for three (3) hour inspection time for MAR I any off -hours inspection work at $100.00 per hour (minimum total of $300.00). This is to be paid at the time of request. ** `1R41T GEtTEA The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate invoice will be issued for all inspection time in excess of three (3) hours. Signature: �— 2 g Date: Printed Name: %rt c Z,!�:>r in City Use Only: Approved] Disapproved: Date of Approval/Disapproval: Authorized Reviewer: Paid: Receipt No: Remarks: W:\Permit Center\Templates\Forms\off hours inspection 1-2015.docx Revised: January 1, 2015 SINE WAVE ELECTRIC INC Washington State Department of Labor Industries SINE WAVE ELECTRIC INC Owner or tradesperson DILORETO, ERIC M Principals DILORETO, ERIC M, PRESIDENT DILORETO, CHRISTINE A, SECRETARY DILORETO, ERIC M, AGENT Doing business as SINE WAVE ELECTRIC INC WA UBI No. 602 811 909 License Home Inicio en. Espahof Contaci. Safety Claims & Insurance 10820 150TH ST E PUYALLUP, WA98374 253-770-9283 PIERCE County Business type Corporation Page 1 of 2 Search L&I A-'7.. Ind( Workplace Rights Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ............................................................... Meets current requirements. License specialties GENERAL License no. SINEWWE922JQ Effective — expiration 04/18/2008— 04/18/2016 Designated administrator DILORETO, ERIC MICHAEL License type Master Electrician Bond ................ CBIC Bond account no. SH8012 Active. Meets current requirements. License no. DILOREM922DR $4,000.00 https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602811909&LIC=SINEWWE922JQ&SAW= 3/11/2015