Loading...
HomeMy WebLinkAboutPermit EL15-0323 - DUONG RESIDENCE - SOLAR POWER SYSTEM ON ROOFTOPDUONG RESIDENCE 1423159 TH AVE s EL15-0323 City of Tukwila ' Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov Parcel No: 3365901155 Address: 1423159TH AVE S Project Name: DUONG RESIDENCE ELECTRICAL PERMIT Permit Number: EL15-0323 Issue Date: 4/23/2015 Permit Expires On: 10/20/2015 Owner: Name: DUONG NGOC-TRAM+THO XUAN Address: 1423159TH AVE 5, SEATTLE, WA, 98168 Contact Person: Name: JESSE ANDERSON Phone: (206) 317-4656 Address: 2444 FIRST AVE S , SEATTLE, WA, 98134 Contractor: Name: A & R SOLAR Phone: (206) 707-9937 Address: 2444 FIRST AVE S , SEATTLE, WA, 98134 License No: RSOLAS*903JM Expiration Date: 5/20/2016 Lender: Name: Address: DESCRIPTION OF WORK: INSTALL A 9.8 KW PHOTOVOLTAIC SYSTEM ON THE ROOF Valuation of single family: $17,965.00 Fees Collected: $70.98 Valuation of mf/comm: $0.00 Type of Work: REMODEL Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: c Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: p Date: L( Z �5 Print Name: `Z This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. ELI E— Os)-3 Project No. Date Application Accepted: —t,(T Date Application Expires: 11) ( U` (For o tce use on! ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: Site Address: 14231 59th Ave S Suite Number: Floor: Tenant Name: Tho Duong New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: Tho Duong Address: 14231 59th Ave S City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Jesse Anderson Address: 2444 1 st Ave S City: Seattle State: WA Zip: 98134 Phone: !7l1�'��_����5 Fax: Emai. Jesse@a-rsolar.com ELECTRICAL CONTRACTOR INFORMATION Company Name: A&R Solar Address: 2444 1 st Ave S City: Seattle State: WA Zip: 98134 Phone: (206) 707-9937 Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; '-2o6"31;7-V6 6 Valuation of Project (contractor's bid price): $ 17,965 Scope of Work (please provide detailed information): Installing a 9.8kW Photovoltaic System on the roof Will service be altered? ❑ Yes m No Type of Use: Back feeding PV Production to PSE Type of work: ❑ New m Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served bv: ® Puget Sound Energy ❑ Seattle City Light MApplicationsTorms-Applications On Line\2014 Applications0ectrical Permit Application Revised 1-1-14.docz Revised: January 2014 bh Adding more than 50 amps? ❑ Yes m No ❑ Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page] of 2 V 1 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings...................................$152.85 (including an attached garage) ❑ Garages. pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits.................$81.90 number of added circuits .......................$11.55 ea Circuits added/altered without service change ........... $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits)...............................................$7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH. .PERMIT WELL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 04/10/2015 Print Name: Jesse Anderson Day Telephone: (206) 317-4656 Mailing Address: 2444 1 st Ave S. Seattle, WA 98134 City H:\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $70.98 EL15-0323 Address: 14231 59TH AVE S Apn: 3365901155 $70.98 ELECTRICAL $68.25 PERMIT FEE SINGLE FAMILY R000.322.101.00.00 0.00 $54.60 PLAN CHECK FEE R000.345.832.00.00 0.00 $13.65 TECHNOLOGY FEE $2.73 TECHNOLOGY FEE TOTAL PAID BY ' R000.322.900.04.00 0.00 $2.73 $70.98 Date Paid: Friday, April 10, 2015 Paid By: JESSE ANDERSON A & R SOLAR Pay Method: CREDIT CARD 058605 Printed: Friday, April 10, 2015 1:15 PM 1 of 1 CSYS7EM5 INSPECTION RECORD / � Retain a copy with permit w: ,05z INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36i Permit Inspection Request Line (206) 438-9350 Project: _ 1 JI/t�/V Wes Type of Inspection, Address. 111z) 1 . / Date Called: Special instructions. V/ Date Wanted: ajn. p,rrs Requester: Pore No: FlApproved per applicable codes. ® Corrections required prior to approval. l� paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. I CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: D WA e of Inspection, TypeJ Address: i Date Called: Special Instructions. Date Wantea­ a,M. /0 Requester: I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Galt to schedule reinspection. No chant of wo Tt MOTE: Revi and may 9.8 kW Solar PV System Tho Duong 14231 59th Ave S. Tukwila, WA 98168 REVISI NS shall be made to the scope without prior approval of vita Buildi g Division. ns will requi e a new plan suhmitt�+ lode additio al plan rep,, ' \wf fees. 36` 8 K IT 10 sit, x # V V FILE COPY Pearmit f®, Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize I e violption of any adopted code or ordinance. Receipt f approvec Field Copy and conditions is acknowledged: Da e: / Z 1` 6" -)`10l 10 5!3'. City of Tukwila BUILDING DIVISION 3 11!16 r He'VI` CE W TH CO,M PA70 _ NEC NF APR 2 0 2015 11 a — city of_Tukwl _.181111 3- a w 0 Lnn 9.8 kW SOLAR PHOTOVOLTAIC SYSTEM PSE GENERATOR Solar PV Array Module: Itek ITE 280 Power Output: 280 Watts (DC) Qty: 35 Modules Total Max Output: 9.8 kW DC Location: Roof top 2 Strings of 11 modules 2 conductors, #10 in V4" EMT V(oc)= 43.4VDC ■ ■ ■ 11 modules 11 modules 13 modules (west (—L.auf) (—si w Q CENTRALINVERTER (1) Solectria PVI 5200TL* Max Output: 5200 W AC Output Voltage: 240VAC + Max Output Current: 21.6A String or 13 modules I 2 conductors, trio in 3/4" Ervrr qoc) = 561.8 V DC I I 1 lsoa I (1) Solectria PVI 3800TL* i Max Output: 3800 W AC Output Voltage: 240VAC #6 GEC Max Output Current: 15.8A I Location: Exterior *Made in WA by Itek I I (3 conductors) AC SUBPANEL/COMBINER i #10 in 3f4" EMT Rating: 100 A/ 240 V AC Solectria 5200 (1): 2p30 A l Solectria 3800 (1): 2p20 A Location: Exterior i I i I (3 conductors} SERVICE METER #6 in 3/4" EMT � i PRODUCTION METER Rating: A AC Line Location:: Cc) -located with Meter n *Meter polarity as shown* i M q = rn�7'[I7 z0�o 0 � O b �zy is AAA rz g rn m 0 0 � 0 rn mc�� 0rn0T O�r" COOn m? �rnN-]n ron f� nz0OTzz >0b D3N z 0zO3 n zv0� �WZ Prrnnz a0;0 rn T O #6 GEC i SUPPLY SIDE —� Load CONNECTION LOCKABLE FUSED l 1 AC DISCONNECT i MAIN SERVICE PANEL Service Rated / 2-Way Interlocking Rating: 60 A / 240 V AC I Type: Knife Switch #6 Fuse: 50 A I Location: Co -located with Meter l I I-- - — — — — — — — Total System Voltage Drop: 1.57% J_ Customer: Tho Duon Address: 14231 59th Ave S A&RSo'lar Tukwila, WA 90160 Phone Number: 206 335-1855 2444 1st Ave South, Seattle, WA 98134 ProjectMgr: EvanMand er ac Phone: (206)-743-4634 (800) 714-1834 3D Renderingof Proposed System & Single Line p Y 9 A &RS o 1 a r 24441st Ave S,Seat 8M714- Ph: 206707-9937 I Fax: 800.7141834 S'°N3 MM/Dn;SY HF:e.InItKS --/--/-- --/--/ _ Tho Duong PV System 9 ECEIVED OF TUKWILA 10 2015 RMIT CENTER Site Conditions Lowest Record Ambient Temp ('F) 19 Average High Ambient Temp ('F) N Record High Ambient Temp ('F) 91 Inverter Specs Sclectria PVI-52DOTL Solectria PVI-3B0GTL Inverter Output Voltage 240 240 Inverter Max Amps Out 21.6 15.8 Inverter OCD Size 30 20 N of Inverters 1 1 AC Comb. Max Amps Out 37.4 Equipment Solectria PVI-5200TL Solectria PVI-380OT1 Mppt Input 1 12 1 1 2 Module itek-280 itek-280 N Modules per String 11 1 11 13 N Parallel Strings 1 I 1 1 Number of Modules per Mppt 11 111 13 10 Total Number of Modules 22 13 Number of Inverters 1 1 Panel Specs itek-280 Temp Adj. itek-280 Temp Adj. Imp 1 8.6 1 1 8.6 Vmp 32.3 31.9 32.3 31.9 Voc 39.2 43Z 39.2 43.2 Isc 9.3 1 1 9.3 Vnom 0 1 10 Array Specs (Adjusted for Temperature) Inverter Solectria PVI-5200TL Solectria PVI.380OTL Mppt Input 1 2 1 1 2 Amperage (Imp) 8.6 8.6 8.6 0 Voltage (Vmp) 350.8 350.9 414.5 0.0 Voltage (Voc) 475.4 475.4 561.8 0.0 Max Amps (Isc) 9.3 9.3 9.3 0 Wire Ampacity Note Wire Type AL/CU Temp Rating Wire Gauge ft of Conductors Paralleled Conductors? Conduit Type Height above roof Conduit Fill Multiplier Temp Adder Ambient Temp Correction Base Wire Ampacity Derated Ampacity String 1 to Inverter 1 THHN, THWN, THWN-2 CU 90 30 2 No EMT 0 10096 0 1.05 40 42 String 2 to Inverter l THHN,THWN,THWN-2 CU 90 30 2 No EMT 0 10096 0 LOS 40 42 String 1 to Inverter 2 THHN, THWN, THWN-2 CU 75 10 3 No EMT 0 10096 0 1.07 35 37 Inverter 1 to AC Combiner THHN, THWN, THWN-2 CU 75 30 3 No EMT 0 100% 0 1.07 35 37 Inverter 2 to AC Combiner THHN, THWN, THWN-3 CU 75 10 3 No EMT 0 100% 0 1.07 35 37 AC Combiner to Production Meter THHN, THWN, THWN-4 CU 75 6 3 No EMT 1 0 1 100% f 0 1 1.07 1 65 1 69 Production Meter to AC Disconnect THHN, THWN, THWN-S CU 75 6 3 No EMT 0 100% 0 1.07 65 69 AC Disconnect to Splice box THHN, THWN, THWN-6 CU 75 6 3 No EMT 0 100% 0 1.07 65 69 Voltage Drop Note One Way Length (ft) Voltage Source Nominal Voltage Continuous Current Voltage Drop String 1 to Inverter 1 100 MPPT3_3 Subarray 351 11.63 0.82%. String 2 to Inverter 1 100 MPPT2_1_Subarray 415 11.63 0.70% String 1 to Inverter 2 100 MPP71_1_Subarray 351 11.63 0,82% Inverter 1 to AC Combiner 10 Inverterl 240 21.60 0.22% Inverter 2 to AC Combiner SO Inverterl 240 15.80 0.16% AC Combiner to Production Meter 5 Inverter Bank 240 37.40 0.08% Production Meter to AC Disconnect 5 Inverter Bank 240 37.40 0.08% AC Disconnect to Splice box 5 Inverter Bank 240 37.40 0.08% Total Voltage Drop: 1.28 Notes Grounding GEC Size 6 EGC protected? yes Largest DC Conductor Size 10 DC EGC Size 10 Ungrounded AC conductors (AWG) 8 Main Service Panel Main Breaker 200 Bus Bar 200 Max PV OCD Allowed 40 Max OCD per Inverter Specs 30 Combined Inverter OCD Size 5o Name: Tho Duong Address: 1423159th Ave S Tukwila, WA 98168 m DMPL �NfCE WI H WFPA 70 - fNE(; APR 2 0 2015 j i RECEiV D CITY OF TU WILA APR 10 PERMIT CENTER Engineering A&RSolar Ph: 206-707.99371 Fax: Wo-7198 1MA ALV192D.S reu/nn,»' xrauxxs Tho Duong PV System N O Solar Modules The high performance, high quality and affordable solar solution • Made -in -Washington using Cutting Edge High Efficiency Mono Crystalline Cells • 25-Year Power Output Warranty • 10-Year Workmanship Warranty • Exceptional Power Density (watts/m7) •00 �. •. CY wPe 60 x�lON ,E�Naw Y ��M wOlZ LV+,www ,I.:' •N11'%T .. • ._ .�.. _._ .- y-w'. e3 t11 GA.a ueocMtr bwYm Nrlp•rem s91o. 9k1•wan «u.•up p!arroke pArelxs lea'Ne - _ '�".•".�• Mllrww-FU,Mbyn'r•C fY/lA'.r_wn'p-:y1 •.y N.w. Sem.ptlW csa m'. °+^' •'°_ 1'^'�.r'1"• 0vf I ow l COrt'p0' a:2 w ^.. lYi^ 1l111-E7,7w'n [-.:a^.pt O10 con b0"arrt[Ylq mdm'"y •fAenwpa Ao,tirya r.ww�vey Iw.. m.r..e oaxr.� earw5 YM mVm Syf•m Va• 62'v 6 p•MpnrHSM �79PI .ASb .l3 asln _ • •.q r%ve++p5c•Sopey A+, w>err:;, u.,. ix+icon :.l ap..,,rm�w a.•wl«n••paca•on � anYP.•.en lreq mea - -.�tn1'I' .__.� . Ce91a .?"9�'2w WGN♦N-9 wasM rrr Aoawp iy. Ce•.rAw 6K• In.x ee•�w Cwem____�3A - 6wr-Jrq f-e fitM la Wp�aleyLEPyy-.p W iw- tXi'F: kaiG't:ru PCn'rocAAt ka r•OArt.OE 4. woo btl'0.9l wel�AP n.'1i0'9 16171- (6a 81 - . � la.,.•r awlrA,• CZ' utemA..ev.lr•OGq _ _.. __ 3 - lwne�,el c.ac«vr r. �i L/S[ y'j -' s.c7arne CerlmrrY Gas%/'C ` 50-,,(2-tMCk) 8acka,d• O1Sol- Modul* • a lMy L'..Rtl O• n•n.Y.a F^.o.,C mOdA•wn /9ww-I�IW►) _?55 M 76s ?20 275 ?DO aSnknVrn rover vrpr•V_IY131.5 31.7 31A 37D 32.1 321 Npda S+wsN.)fa S'.lf! . ti...:e1. u,ii a.i • e i 6� -s.a es - a.e " O DPw CacA Vebpr • Y_. IVI M.a 366 38-7 369 39.0 39.7 -&0 inrr CASH Gunlr-t 14 8.9 9109.1 9.2 93 r�w enlYl(w `')ISQa 111.9 16%.9 166D ma {.ACki� '`�rgy _•�--}•r�5-8 Yb.9511 56os M., 1 0.eWnaryyapn 4 25 Abwlule Ws - OPIn Cimh Vollate op-OnL Voaaae 9ana! we YOC 120-sSO VOC JAMMWIV0 82t Rana! 200.50(1 D MPPT.,k I 2 M M-. Op-fl.. Mput Current 20A ISAptr NPP-w 18Apm MPPUKaee 70Aper MPPUackm 5 Shn VOltaae INN 9 NgnIM10u1W1Y011aL! 203o1260VAC. I.. €' AC VoluLa Ilaaae -12N7.30% ? Conammus0utpul Power 20VAC 3NOw 52WW 6600W 6ww 210VK Unew 5200w 66o0W 7600W 208YAC 154A 25A 31.7A 31.7A ContllWWSOwput Current 21o.c IMA 71.6A 21.5A 11.7A Maximum eacklead Curtem oA Nominal0ut0ut rlaquan<y 60 Mr 0u1WI Frequency Rance 59.3d0.5 N1 Power Factor Un1ty,'059 Tra1 ammonk Dl-nlon (MD) • Rated IOad r Dr. PwxFAldanty 98.T5 CEC EMulncy 97.5% see Iws Ow AmNem Tempcnlwe Rante 0YR DOweO -13•Fto.122•F(-35•C M.5t1.O 5-4. Temperatwe Rance -e0•Fto.1R5•F(iOK to NS'Q Rtlallva NYnddilY Dm0'LOnOanSllrV O]0o% op rna Abkud! 6562fVMC)n, optional SobenVaw web-ba.e4 Mo0kolft E+lemal Opaonal Revenue Gmde N011tm101 E-1 Eatmntl Communk&fl nlmerram P-5<05 Safety Ustlnae a Clnifl-1 ns U11741/IEEE1547.UI16998.CSAC22.29101.1,FCCpanl5MB T,WU XAS-y ETI cm sllndlld loyem aptlonal - Ofixo llbeO Ruml uSd5A•I. OC Diacomttl Stan6ard, lulh InteDatH Oimenalona pAN'w D) 17.SA15.a+M. 26.6a15.6+6.SIn- ' (aa5+e01 a 216 m110 (6e01 a01 .216 mm) Welsbl 4316509.5 V) 65 IN 09.5 kg) Embawe Racir, rvp a. San Mal Cwmuon P1aecUon Enclowre 1w. Numinum SOLECTRIA AYAaKAWACOMPt" www,solectrla.com I Inverters®solectrlasom I 978.683.9700 KUP-L-Tape Insulation Piercing Connectors RoHS 9 SF7 Colnpn•nt USTED Dual Rated 4a9G TYPE •C�BuoQlnpvopiLLSdpndnUN han bupM1 reti1ett91�6Med rlrtal :Rundes*dapmrte�ta'yeprevstageremunooalWWVdepmdabk m IPC:T oaaa eab� s aaN(is:BsW on me ••3.6•e .Prettied wLh L"fLale Wiaa •Ravens oadxDn and rrl9emre bam ela•ilg dlemudafd •n •V•Sasa • Candltseda5ernalw hplprY•Ca •krmasedsalery •Coruirc no external ad Pane Can 6e irAUCed'har an all(rgbadcay • NorSmul i1n •FYmvdni55autgu�ide 'sFouCatierbad 'd1u015 •lampe2uuM 96•C W L Q. �_ ��U f ot. Fig. 1 Fig. 2 Fig, 3 Fig, 4 Catalog Numbar Figum Number Wile Ra Yau Correm CU RLting AL Dimansiom - Torgw PL Lbs. Bob (lead sae Main Tap L W N 1PC-W2 3 108 28 3DD=U 4WYSyW... 130 100 1.7132 1.1SM 2-06 16 112 KAU 2 40-4 04 e00 75 60 1.27ra 1 1-718 13 12 PC-R020 3 4.&2 7A6 BID 195 150 1=2 1.7E 2-7,8 25 17 PG2504J0 2 250ami*l 406 BID 26D 205 1-7/9 2-11M 311W 3D 58 K-35DAG 3 359X.1.6 4010 ZOVA C--W YSIM-. 20D M 14164 27,16 31S 25 se FC3%350 4 35%za41D 350ccrnd-o 3DDIWGKWMY 350 280 24364 2-23= 3LP 25 5e PC-5*12 1 SOX.1F2$01mi 1012 300880WNAWY$ls•e. 40 35 14W 2.716 3A% 25 56 PC-5*250 1 503vni aari 250Fc1iH 6DD 29D 230 2.27A4 2.2532 331 55 S&R16 VC-500500 1 50K.11. orii 50OWW-M-11 60D 430 350 3316 358 5 75 7,1&7,8 IPVW500 1 750Vomi50OWN SO onnl-Mcrlw 600 0 350 33no 36,8 5 75 7t8.7,8 Al wire sires. uIlen WA OthemiSe, are AmadonWnGauge (AN) Taxed 1017L 406A8, UL Fik EW 105 O 4730 Mad'Ism Road, Cincinnati, Ohio 45227-1426 Phone 513 5338200 Fax 513 871-4084 Web she vm Aisco.com Canada 10501akeahore Road EasL Mississauga, Ontario, Canada LSEIR Phone 905 274.2341 Fax 905 274 9763 eu COMPLIANCE�, %FPA?0 ppR 20 2015 tY o�To�la RECEED RU1LDG �Iv�S1 IVCITY OF TUKWIL. APR 10 2015 PERMIT CENTER Data Sheets A&RSolara 2444 1st Ave S, Seatdo, INA 98134 RI: 206-707.9937 i Fax: NO.714-1834 RGVI97O.9 N51/IlDJ11' NhllAll%a Tho Duong PV System 3 0 R. PERMIT COOR® COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0323 DATE: 04/10/15 PROJECT NAME: DUONG RESIDENCE SITE ADDRESS: 1423159 AVE S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: o6 Iry Building Division Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Fire Prevention ❑ Structural ❑ Planning Division ❑ Permit Coordinator a DATE: 04/14/15 Structural Review Required ❑ DATE: DUE DATE: 05/12/15 Approved with Conditions d Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 A&R Solar Page 1 of 2 Home Inicio en F.span"ol Contact Safety (0 Washington State Deparhnent of Labor & Industries A&R Solar Search L&I A-Z Index Help boy Secure L&I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 24441st ave s CLIPPARD, WILLIAM R SEATTLE, WA 98134 206-707-9937 Principals KING County CLIPPARD, WILLIAM R, PRESIDENT YATTEAU, ANDREW, VICE PRESIDENT CLIPPARD, WILLIAM R, AGENT Doing business as A&R Solar WA UBI No. Business type 602 707 872 Corporation Parent. company A AND R SOLAR CORP License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ............................................................... Meets current requirements. License specialties GENERAL License no. RSOLAS'903JM Effective — expiration 05/20/2010— 05/20/2016 Designated administrator Ci'ippard, William License type Electrical Administrator Bond ................ CBIC Bond account no. S16249 Received by L&I 05/20/2010 Savings No savings accounts during the previous 6 year period. License Violations ......................... _............................. No license violations during the previous 6 year period. Active. Meets current requirements. License no. CLIPPW'902JN $4,000.00 Effective date 05/17/2010 Expiration date Until Canceled I Workers' comp I Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602707872&LIC=RSOLAS*903JM&SAW= 04/23/2015