Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL15-0444 - WASHINGTON PLACE - TEMPORARY POWER
WASHINGTON PLACE TEMPORARYPOWER 223 ANDOVER PARK E EXPIRED 12111116 EL15-0444 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov ELECTRICAL PERMIT Parcel No: 0223100090 Permit Number: EL15-0444 Address: 223 ANDOVER PARK E Issue Date: 8/31/2015 Permit Expires On: 2/27/2016 Project Name: WASHINGTON PLACE - TEMP POWER Owner: Name: SOUTH CENTER WA L L C Address: 8448 N MERCER WAY, MERCER ISLAND, WA, 98040 Contact Person: Name: FRED JONES Phone: (503) 608-2264 Address: 6412 S 196TH ST, KENT, WA, 98032 Contractor: Name: E C COMPANY Phone: (503) 224-3511 Address: 6412 S 196TH ST, KENT, WA, 98032 License No: ECCOM**148BA Expiration Date: Lender: Name: Address: DESCRIPTION OF WORK: PROVIDE TEMPORARY POWER FOR CONSTRUCTION SITE, INCLUDING CONSTRUCTION TRAILERS. This permit is for temp power for construction (trialers, temp power poles, etc) of new building. Valuation of single family: $0.00 Fees Collected: $2,798.96 Valuation of mf/comm: $141,000.00 Type of Work: NEW Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit, Center Authorized Signature: "i ( �NO Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit aadla-aee to the conditions attached this permit. Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKW. Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov SITE LOCATION Site Address: Tenant Nam Electrical Permit No. X, V Project No. Date Application Accepted: Date Application Expires: _ use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" PROPERTY OWNER Name: I(1 LLL C rtyt� Address: E City: ate: C D CONTACT PERSON — person receiving all project communication Name: � Address: . City: YaevA� State: Zip: Phone��(ft zo Fax: Email: U King Co Assessor's Tax No.: Suite Number: New Tenant: Floor: ❑ ..... Yes ❑ .. No ELECTRICAL CONTRACTOR INFORMATION Company Name: 1:—� L cnn� n A Address: Vo ba I T) 1 w �U City: State: Zipr} -7 l 36 Phone: &Alc Fax: O Contr Reg No.: _ 1�Date:� Tukwila Business License '.; �O qLb Valuation of Project (contractor's bid price): $ J)COD Scope of Work (please provide detailed information): k 10 10 it PP,P 10 Will service be altered? Q' Yes ❑ No Type of Use: o KA, ` A.. e 4� Type of work: ER" New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: tg� Puget Sound Energy ❑ Seattle City Light HAApplications\Forms-Applications On Line\2014 ApplicalionsTlectrical Permit Application Revised 1-1-14.docx Revised: July 2013 bb Adding more than 50 amps? Yes ❑ No ❑ Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page I of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings...................................$152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat).................................$59.85 ea RESIDENTI_AL REMODEL AND SERVICE CHANGES ❑ Service change or alteration.......................................$81.90 (no added/altered circuits) ❑ Service change with added/altered circuits.................$81.90 number of added circuits .......................$11.55 ea ❑ Circuits added/altered without service change ............ $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ............ $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair........................................................$68.25 ❑ Low voltage systems.................................................$59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) .................................. $65.00 Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ................ $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Mailing Address: (Dq I � S. Lq V3 0V1 014, te: 3— (026 " RA0 i �A g9e3) State Zip H:\Applications\Forms-Applications On Line\2014 ApplicationsTlectrical Permit Application Revised 1-1-14.docx Revised: July 2013 bh Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $15,616.87 D15-0210 Address: 223 ANDOVER PARK E Apn: 0223100090 $12,817.91 DEVELOPMENT $12,207.75 PERMIT FEE R000.322.100.00.00 0.00 $12,203.25 WASHINGTON STATE SURCHARGE 6640.237.114 0.00 $4.50 TECHNOLOGY FEE $610.16 TECHNOLOGY FEE R000.322.900.04.00 0.00 $610.16 EL15-0444 Address: 223 ANDOVER PARK E Apn: 0223100090 $2,798.96 ELECTRICAL $2,691.31 PLAN CHECK FEE R000.345.832.00.00 0.00 $538.26 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $2,153.05 TECHNOLOGY FEE $107.65 TECHNOLOGY FEE TOTALBY R000.322.900.04.00 0.00 $107.65 Date Paid: Monday, August 31, 2015 Paid By: OMAR LEE Pay Method: CREDIT CARD 01350D Printed: Monday, August 31, 2015 3:20 PM 1 of 1 j!' �J' ISYS7EM5 f , INSPECTION RECORD Retain a copy with permit C�ic INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: f— Type of Inspection: ACIC Address. ® Date Called: Special Instruc ions: Date Wanted: ` a.m c l p.m. Requester: Phone No: d Approved per applicable codes. 11 Corrections required prior to approval. INSPECTION RECORD I / ��� R�' o Retain a copy with permit l��✓' INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 0A Type of inspection: Address: 2-2-30( Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: ❑ Approved per applicable codes. EJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD 164(4/� Retain a copy with permit INSPE TION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION f 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 ` Permit. Inspection Request Line (206) 438-9350 Project: PL4a rw Type of Inspection: Address: t r Date Called: Special Instructions: Date Wanted: a. p.m. Y.11 Requester: Phone No: 3)0� Approved per applicable codes. E Corrections required prior to approval. COMMENTS: t�LC REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectiori. INSPECTION RECORD Retain a copy with permit `�'�) INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 4 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: E-P Type of Inspection: Address: ') A--Pf- Date Called: Special Instructi s: Date Wanted: a.Ln. Q p.m Requester: Phone No: ❑ Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD1 7 Retain a copy with permit INSPECTION NO. PERMIT NU. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: (Al,,�- r Pt-�C& Type of Inspection: / Address: az C Date Called: Special Instru tions: Date Wanted: / / L/ %i p.m. Requester: r!77m " Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD ,�/, ✓®,f� Retain a copy with permit INSPECTION NO. PERMIT I CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: r --roe- Type of Inspection: Address: Date Called: Special Instruct' ns: Date Wanted: Requester: Phone No: ElApproved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD j ✓�F`' �l Retain a copy with permit INSPECTION NO. PERMIT NU. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: A � e (� Type of Inspection: Address: Date Called: Special Instructi ns: Date Wanted: a. /0 p.m. 07 Requester: Phone No: nApproved per applicable codes. Corrections required prior to approval. COMMENTS: e v' o 77 Inspector: � i A Date: l REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit tv '0 INSPECTION NO. YERMIT ND. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: i Wk- t P Type of Inspecti n: 17�DL-e6(wJ�f Address: 5 Date Called: Special Instructi ns: Date Wanted. a.m. �o d� p- Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: VA r `� t f !r --ZY,2 Co t Lo Inspector: j1 d6,o_ dK IDate: N102 15 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD/ Retain a copy with permit INSPEC ION N0. PERMIT NU. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd— #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � A� LCI)'e Type of Inspection: Address: 7,25 Date Called: Special Instructions: Date Wanted: a.m. Z' p.m. Requester: Phone No: 11 Approved per applicable codes. E Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaR to schedule reinspection. INSPECTION RECORD (N5 ,���1 -3 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � � t�r� Type of Inspection: �:�� ✓iC.t Address: ,t p� Date Called: Special Instructions: Date Wanted: ! r ap.m Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: ) . 06 Date Called: Special Instructions: Date Wanted: Qp a. P• Requester: Phone No: 3YY 3oc Approved per applicable codes. E Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. f INSPECTION RECORD ` Retain a copy with permit IM INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: P i Type of Inspe i n: r jN'P Address: 77 Date Called: Special Instructions: Date Wanted: a. !� L P•m• Requester: Zj kZl L Phone No: 36o 2— El COMMENTS: r nspector: WIE REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 11/1/2016 FRED JONES 6412 S 196TH ST KENT, WA 98032 RE: Permit No. EL15-0444 WASHINGTON PLACE - TEMP POWER 223 ANDOVER PARK E Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/1112016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/11/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: EL15-0444 6300 Southcenter Boulevard Suite #100 • Tukwila; Washington 98188 e Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director June 09, 2015 FRED JONES 6412 S 196TH ST KENT, WA 98032 RE: Correction Letter # 2 ELECTRICAL Permit Application Number EL15-0444 WASHINGTON PLACE - TEMP POWER - 223 ANDOVER PARK E Dear FRED JONES, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - E DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. • CORRECTIONS/ #1 SHEET TEMP PWR#2 -OCPD FOR "TEMP. HEAT" UNDERSIZED AT 30 AMP -CLARIFY WIRE SIZE FOR FEEDER CALLOUT #6 -TRAILER POWER TRANSFORMER PRIMARY APPEARS UNDERSIZED FOR LOAD. FEEDER CALLOUT #8 100 AMP Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-433-7165 . Sincerely, W,�Y Rachelle Ripley P y Permit Technician File No. EL15-0444 6300,Cnuthnantor Rnnlavnrd .Cuity #lnn • Tu" iln Wn.chinotnn 9RIRR a Phnnn ?nA-d31.3Fi7n • Fnr ?n6_d31_3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0444 DATE: 06/15/15 PROJECT NAME: WASHINGTON PLACE - TEMP POWER SITE ADDRESS: 223 ANDOVER PARK E Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: )Ii� ffifi:�. Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 06/16/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DUE DATE: Approved with Conditions Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 07/14/15 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0444 DATE: 06/03/15 PROJECT NAME: WASHINGTON PLACE - TEMP POWER SITE ADDRESS: 223 ANDOVER PARK E X Original Plan Submittal :Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: a (cvv, V t - is Building Division a Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 06/04/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required (corrections entered in Reviews) Notation: DUE DATE: 07/02/15 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: 9z 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: b.4p://www.TukwilaWA.jzov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, eta Date: June 15, 2015. Plan CheckTermit Number: EL 15-0444 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: WASHINGTON PLACE - TEMP POWER Project Address: 223 ANDOVER PARK E Contact Person: Fred Jones Phone Number: 503-680-2264 Summary of Revision: Re- design of Temp power and corrections to feeder sizes PFERM1T i304TEP Sheet Number(s): Temp Power #1 and Temp Power #2 "Cloud" or highlight all areas of revision including date of revision, c Received at the City of Tukwila Permit Center by: Entered in TRAKiT on ((2 —( '�- —('- T:\Shared_C\2014 Seattle lobs\81710 - Washington Place Precon\Submittals\Revision Submittal Form EL15-0444 City Of Tukwila.doc Revised: March 2014 E C COMPANY Pagel of 3 Home 1nicio en l;spanol Contact Safety Washington State Department of 41-abor & Industries E C COMPANY Search L&I I A-G Iudex Help Nly Secure. L&I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson ATTN K ROBERTSON PO BOX 10286 PORTLAND, OR97296-0286 Principals 503-224-3511 ADAMS, GEORGE HARRY SCROGGY, JOEL J JANIK, STEPHEN THOMAS, VICE PRESIDENT BOCK, JAMES ARTHUR, VICE PRESIDENT BUSINESS FILINGS INCORPORATED, AGENT GOLDSTONE-SCHULLER, LEAH, MEMBER TRAPP, STEVEN C, MEMBER SCHMITZ, STEVEN D, MEMBER BALL, ROBERT SPENCER, MEMBER DESHLER, WILLIAM K (End: 06/28/2010) KELLY, RAYMOND THEODORE (End: 06/28/2010) PRENTICE-HALL CORP, AGENT (End: 06/28/2010) Doing business as E C COMPANY WA UBI No. Business type 601 107 330 Corporation Governing persons MALERIN F HAW LEY ROBERT S BALL; STEPHEN T JANIK; WILLIAM K DESHLER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ........ _.................................................... Meets current requirements. License specialties GENERAL License no. ECCOM**148BA Effective — expiration 01/01/1986— 06/30/2016 Designated administrator BAKER, DON E Active. Meets current requirements. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601107330&LIC=ECCOM**148BA&SAW= 5/18/2015 v J t1 Z 0 Z_ to rM tM 00 O u7 O i 0 0 0 11-1 O rn O rn O O J 0_ Z O Z U) U U Z d- 0 N H Z Lv Y T O N z `1 0 0 E a I u7 0 N of 0 r� ITIONAL LIG POTELCO DESIGN AND '1 QUALITY ASSURANCE ❑ This design complies with PSE Design/Engineering Standards. Any/all variations have been pre-approved/documented by the appropriate PSE Representative. Signature Print Name Date I 1 4 A � �:It• I7•! I7• I�� �:It• Imo! I� Van_ ON V12AOE/ r OENE,,,ON ONEWAY '• •- - -• rc1:'���,�►�ar1�c����,�T�,'Zos�1d�,, _i"'��1'1r�"���:�>•r �31A EROSION & SEDIMENT CONTROL R'EQUIREMEN S 1 EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD RACTICE 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT ONTROL 1 &ANY ADDITIONAL LOCAL JURISDICTION REQUIREfyIENTS. (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS IN LUDING 1 JOB SITE NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRU TURES ARE TO BE INSTALLED, CROSS SECTION DETAILS OF\THE TYPICAL E OSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORD IN SENSITIVE REAS.) 11 SCALE: 1 " = 40' ROADSIDE 20" Min Final Grade 30' NEW 1-4" J02 36" Min NOTE: 48"\� 12" Min Cover Backfill, Bedding, and Max \; Separation �� Shading requirements are \� \/' contingent upon the soil type present on site, and shall be specified at the \� — \/, pre -construction meeting \% after composition of the native material has been determined. Communications Primary Power Cables or Conduit CUSTOMER SUPPLIED TRENCH FOR PRIMARY CABLE STD. PRACTICE 6790.0130 - SCALE: NONE 1 8' GROUND ROD'S 101 TEMPORARY CONCRETE PAD 81 _ OBI 30 PRIMARY CABLE r; IN 14" PVC CONDUIT TRANSFORMER CABINET FOOTPRINT 6" CRUSHED ROCK BEDDING TOP VIEW TRANSFORMER & PAD - DETAIL STD. PRACTICE 6315.1000 - SCALE. NONE 1' 0 0 0 0 o 0 0 4'-0" 7'-011 \ 4'-8" F.H. e RAMP UP 1 1 1 i IM■■■r■■■■■■■■■■■■■■■■■■■tl11 1■■■■■■■■■■■■■■■■■■■■■■■ER 1■■■■■■■■■■■■■■■■■■■■■■■■MI 1■■■■■■■■■■■■■■■■nllr■r.•■�a11 1■■■■■■■■■■■■■■■■r■■■■■■■011 1■■■■■■■■■■■■■■■■■■■■■■■■011 1■■■■■■■■■■■■■■■■■■■■■■■■w11 1■■■■■■■■■■■■■■■■rr■■rr■ra11 low ■S■■■rr■rr■■■■■rr■■■■■w11 1r■■■■■■■■■■■■■■■■■■■■■■w11 �� 1■■■■■■■■■■■■■■■■■OO■■■[■if911 is CL VAULT & EQUIPMENT TABLE Site Grid Vault Size Type & Size Primaty Bushings Transformer ASBUILT INFORMATION Number & Cover Equipment ID Numbers Foreman -Complete in Vault LB DC ID EXISTING EXISTING —(Company CHARGE TO 101 4'-8" x 7' x 5' -575 J01 * J-Box Matid:- NEW NEW CHARGE TO 101 J02 4'-8" x 7' x 5' -575 6 6 * J-Box Matid:- * 8' x 8' SQ Cover 750kVA 277 / 480V CHARGE TO 105 Vol W/ 24" x 60" Access Matid: 6259300 3 - Matid: 9996110 Remove 4'- " SQ Cover Remove CHARGE TO 108 V02 * Vault & Lid 250kVA 277 / 480V 3 _ Matid: **** Matid: **** ■■■r.•.»nu■■■r■■■■r■r■r■r■■■■■■rrall I • ������ i ■r�■vuii111■■woouu■u■u■u■■■■n • I � � • • • • • • • � • � � • ���� ! - i ■rr■�uiuoo■uu■uuuuo■■u■n • ��� � � I - �roi�,■nuuouuoo■orrururrli ■ .. . ♦��� .avrulmuuo■uu■ou■uo■ouni ♦��� ! i■■ ■ ■■, ■uMMU ii iiiiiiiiieiiii I - • C • - - • � � • � � ♦ nurunmu coca■■soli +}'a •, SEMI 1� � i � ���/ - uuuuuuu■urrororuuuuoo■ni ������ ^. �" M!!uuuurunuoroo■onuo■■■■n ,�t�t .. ���♦ 10000:1:001011 ■OMEN.■.■.■■■.`I��R ° ���♦ � muu■muul� � �4�w4� ____ _ �. - I�.uo■uu■■u •go +i■u■■■■earl 1 ������ 1 / / , / Not) ��� wd �q 1 • : • rn .. �No M ■■II (909082� '+' o € rUP J02 INSTALL NEW 575 JUNCTION BOX On Site Superintendent NONCOM cMM7S CANS . INSTALL 3 - 4 POS JUNCTION .•:+: ABSHE R o b o INSTALL 6 - 12KV ELBOW KIT INSTALL 6 - 12KV DUST CAP 1001 1001 Shaw Road Puyallup, WA 98372 :r,ce b ATTN: Joe Hoge - LEED GA 1-253-241-4114 office IP1 W IF'�I`OIWII _ Joe.Hoge@absherco.com '•° Vol INSTALL TEMPORARY TRANSFORMER ON PRIVATE PROPERTY INSTALL (2) GROUNDRODS Project Engineer — EXISTING 1-4" BUILDING ABOVE N 3 co►wuwc�noN c�r'1owTs � 10' UTILITY EASEMENT INSTALL 1 - 8' x 8' LID COVER W/ 20" x 60" ACCESS ABSHER 1001 Shaw Road �„�,,,�, 316 89-164980 _ _ z INSTALL 1 - 750kVA Trf 3Phase PM 2771480 Puyallup, WA 98372 c+ c+ e c+ c # — — :.. . . ........•,..•..••...•. _ INSTALL 3 12kV ELBOW KIT •Josh Beloit ATTN. 1-253-778-3117 office 5 4 W F" 0 316 1 4 8Q josh.beloit@absherco.com _ _ Connect &Tag Customer Ran UG Svc Lines Runs MCM AL. Conductor / MCM AL. Neutral - BLDG A - 1600AMP) 16'-0" 36'.0" 1a'-0" 36'-0" 16' 36'-0" 6'-0" 1v-0" �/2W„ 4 ' 1T-3 CIRCUIT LOADING TABLE 300KVA 316985 5 oa���" V02 REMOVE EXISTING 4'8 SQ VAULT & LID � sn c s - 30' 12 -dbV- , � ICI ""' T ""' V' ; :' REMOVE 225kVA Trf 3Phase PM 277/480 NEW 1-4 REMOVE EXISTING 3 - 12kV ELBOW KIT 0 50, 100, - & RELOCATE EXISTING CABLES 58981 589 2 58983 316987 J01 0 316984 164979 == CIRCUIT: AS OF A PHASE B PHASE C PHASE EXIST. PEAK LOAD EST. NEW LOAD TOTAL ' 164979 - 30 PRIMARY CABLES RELOCATE PRIMARY CABLE & CONDUIT TABLE TEMPORARY CONCRETE LID 6" CRUSHED ROCK BEDDING COMPACTED 36" MIN COVER i i BACKFILL 4" PVC CONDUIT- - — — — — CUSTOMER SUPPLIED SECONDARY PVC TEMPORARY TRANSFORMER INSTALLATION DETAIL STD. PRACTICE 6315.1000 - SCALE. NONE PSE PRIMARY C TERMINALS AT 1 CUSTOMER SECONI CONNECTIONS AT 27i TRANSFORMER & PAD - DETAIL STD. PRACTICE 6315.1000 - SCALE. NONE 11 2 SIDE VIEW .\ ., �\ ❑❑❑ ❑❑❑ 611 9' ❑❑❑ ❑❑❑ Crushed 411 000 000 51% Rock TOP VIEW Excavation - 19-1/2 cubic yards JUNCTION BOX PAD - DETAIL SCALE. NONE CONDUIT PRIMARY CABLE ASBUILT INFORMATION LOCATION Size Qty Design Length ft BENDS REV PULL' Ibs FWD PULL Ibs Cable Size Design Length ft Cable Numbers Please Record Foreman- Complete from to in 90° 45° 22° 11 ° A B C Manufacturer Year Actual Amount Conduit &Cable J01 J02 4 1 30' 2 - - 1/0 JKT 321 58981 J01 J02 - - 1/0 JKT _ 58982 J01 J02 I - 1/0 JKT _ 1 1 58983 PRIMARY CABLE & CONDUIT TABLE CONDUIT PRIMARY CABLE ASBUILT INFORMATION LOCATION Size Qty Design Length ft BENDS REV PULL' Ibs) FWD PULL I (Ibs Cable Size Design Len th MT Cable Numbers Please Record Foreman- Com lets from to in 9001450 22° 11 ° A B C Manufacturer Year c ua Amount Conduit & Cable J02 V01 4 1 30' 1 - - 1/0 JKT 40 AG1078 J02 V01 - - 1/0 JKT - AG1079 J02 I V01 I- - 110.IKTI AG1080 900 450 220 110 4" PVC (ft) & Bends = 601 3 REMOVE PRIMARY CABLE 40' = Total 1/0 AL JKT (3PH) (ft) 1.0 Qts 40' X 3 = 120' 1.0 Total Qts of Glue CONDUIT PRIMARY CABLE ASBUILT INFORMATION LOCATION Size Qty Design Length ft BENDS REV PULL Ibs FWD PULL Ibs Cable Size Design Length ft Cable Numbers Please Record Foreman- Complete from to in 900 450 220 110 A B C Manufacturer Year Actual Amountns a e Conduit &Cable IP1 V02 - - 1/0 JKT 403 58981 IP1 V02 - - 58982 IP1 V02 - - 58983 245' 225KVA 277/480V 403' =Total 1/0 AL JKT (3PH) (ft) JE P' RMIT I ';2UflRE D FOR: rlebl�anical Electrical lumbing as Piping City of Tukwila PilG DIVISION EXPOSED & EXCAVATE 71' FOR REROUTE REVISIONS vo1 Rita 01,1Rnpe^ Shn" bo made to the scope cf prier approval of 30' I `,I'.`1�' IQ CIliNEW 1-4"l. f` m: i 7. k%'310r13 r4l require a new plan submittal J gnd may include additionGl plan review fees. t FILE a9"°e^""'ro j•.' 1 �l7'1ii �. :if �1",rri lr.•4:6� ::.:tiJ AF ULl by atrors .. j and t7fCti6ir.�sls. /"•;=,,.,711t3' r; I. r,.�; IJGti^url documents does not authorize t„9%ia"aFion of any adopted code or ordinance. Receipt of alpprovod Field Copy and itio s i knowledged: By: Date: ?� City of Tukwila BUILDING DIVISION 1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by Potelco's Project Manager and NOTED on the Foremans' Copy. 2. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. 3. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. 4. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. 5. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. 6. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. 7. All work is to be done in accordance with local municipal and county permit requirements as applicable. 8. Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits and crossings from the individual unit's meter base to the designated connection point. 9. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. 10. TEMPORARY PADMOUNT TRANSFORMER AND SERVICE: The cable trench excavation beneath the transformer shall be backfilled and tamped to within 6 in. of finished grade. A minimum 6 in. layer of crushed rock shall be placed and leveled to accommodate the enitre footprint of the concrete pad. The concrete pad shall be placed, leveled, and oriented to allow access, adequate work space and safe operating space for the primary cable elbows, per Standard 0700.1500 Please refer page 2. FOREMAN (CHECK BOX WHEN COMPLETED) ❑ PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. ❑ Grid, Cable, and Switch numbers INSTALLED &VERIFIED. ❑ Field Changes RED -LINED on As -built. ❑ Material VERIFIED and CHANGES noted on Paperwork. ❑ Total PRIMARY Cable noted on As -built. ❑ Company ID#'s RECORDED in correct location on As -built. ❑ Indicate correct FUSE SIZE on As -built & VERIFY proper PHASE. ❑ Deviations noted on the As -built and their reason. ❑ I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. Foreman's Signature Print Name Date PROJECT PHASE NOTIF# ORDER# PWR Superior Perm. Service Relocation Removal Temporary Job Order 501646216 105078335 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A GAS Distribution HP Main HP Svc/MSA N/A N/A N/A N/A N/A N/A CABLE TVNEP 70 .. NEQ PHONE SCALE: NONE ty .:...�,1A C :A RJN 13 39�: • •. U3772 S• S �0 ,w so 3u ,• B'' L VD40 N "&A- 4f 30S 3505�, U752 .'30 S S RJN �• U2160 ... - 229 15 ...•::• ..•;::::::::::r :....... S ;• ; c30 U216•1 S 30 RJ N Q2 -40 � N � '• S U2158 S U363 S S 30 S S S S U2159 RJN 15 : U •3�'r • U3278 U3280 'i f....................� hD STRAMOER :30 & 10 p. S U433 c30 s U225 • S U2408 s U232 :30 : EE 4 RJN -'-: U749 Uc µ1P SEE UG 50U 14 ' 3 234- /O1 AfAP 234 22 .,. SOU 30•S RJN 0 0 v 00 011 w 24 U753 25 • 30 SEE UG SEE Project Manager Contact Information: JUN 2 2 2015 ,yqP 3��; '�....�.....:.• •,� C JNAP 234-104 234-99 Manager. Victor Ibarra ..30 Cell Phone: 253-606-5084 E-Mail. victor.ibarra@pse.com Clay Of Tullwila For contacts below dial 1-888-CALL PSE (225-5773) BUILDING DIVISION CALL (800) 424-5555 Developer Yes x Yes x PSE 2 BUSINESS DAYS BEFORE YOU DIG "Locates Required" NO NO THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES "Outages Required" Yes x No REAL ESTATE/EASEMENT PERMIT "Flagging Required" Yes x No PSE ROW N/A 3 FUNCTION CONTACT PHONE NO DATE 2 PROJECT MGR Victor Ibarra 1-253-606-5084 05-18-15 1 ENGR - POWER Victor Ibarra 1-253-606-5084 05-18-15 REV# DATE BY DESCRIPTION ENGR - POWER Daniel Gakin 1-253-720-4717 05-18-15 COUNTY KING COUNTY Emer Sect Gas Wk Ctr POWER WK CTR QCSOKE DRAWN BY Victor Ibarra 1-253-606-5084 05-19-15 CHECKED BY 1/4 SEC SEC - 18 SE T21 R04E OP MAP PLAT MAP APPROVED BY FOREMAN #1 U-MAP NO (POWER) 2304E101 OH CKT MAP 2305E124 UG CKT MAP 2304EI01 NE CIRCUIT NO RJN-12 / RJN-15 FOREMAN #2 MAPPING JOINT FACILITIES ARRANGEMENTS UTILITIES CONTACT PHONE# PUGE�T SOUND ENERGY DESIGNED BY POTELCO INC Washington Place Residence & Hotel UG Temp Power 223 Andover Park E, Tukwila WA 98108 INCIDENT MAOP Gas Order Elect Order 105078335 SCALE PAGE 01" - 40' 01 / 01 Ll Ll L4 RECEIVED CITY OF TUKWILA JUN032015 PERMIT CENTER •►,. Ilril�l� O0 EXISTING LIGHT FIXTURE TO BE USED FOR CONSTRUCTION n F.H. (D F.H. U r--- 7 I I I MAN LIFT #2 I .. � I 2 1 2"C, W/(4)250MCM AL & 1)#1 /0 AL GND. `�� O�� � . ,.. ^'^!►! awl r 4al , TRANSFORMERgip TEMP POWER JUNCTION:O •PSE - EXISTING LIGHT FIXTURE TO BE USED FOR CONSTRUCTION 400A PANEL CONSTRUCTION _ TRAILERS, SEE ONE -LINE EXISTING LIGHT FI TO BE USED FOR CONSTRUCTION 75KVA TRANSFORMER I77777 \ URE I EXISTING LIGHT FIXTURE TO BE USED FOR 1 CONSTRUCTION-� I� II II I II O II O II II O II I II I, 2 Y2-C, W 2 250 KCM AL &)#1/0 AL GND r-------------------------------, 1 0 -----------�I I CONCRETE PLACI N G BOOM /" W/(4)#B AL i i� i r I I 3 4 C, O � & (1)#5 AL GND. 1 1 4"C, W/(3)#2 AL & 1)#6 AL GND. - ---- _ __-___-_ - - EXISTING LIGHT FIXTURE • ' ^ ' , i TO BE USED FOR 800A i i CONSTRUCTION TOWER (CRANE SWITCHBOARD I �` �i I i i I - 0 • � L�J I 00 4)#S AL GND. --s CONCRETE PLACING BOOM GARAGE SKID C / 4"C, W/(4)500 KCM AL & (1)250 KCM AL (1)#1 /0 AL GND. i I I i I // / .000 2 1 2"C W 4 250MCM AL & 1 1 0 AL GND. i -TEMP 1600A GEAR (4) 4"C, EA. W/(3) AALO L.& (1)#4/0 GND. KCM Ito>I�I� N TEMP POWER ELECTRICAL SITE PLAN r' SCALE: 1/16" =1 4& F.H. MAN LIFT #1 0 75KVA EXISTING LIGHT FIXTURE TO BE USED FOR CONSTRUCTION (EXISTING) (EXISTIG) TRANSFORMER 15KV VAUNTS VAULT CORREC ION LTR# 1 1 1 /2"C, W/(2)#1 /0 I O AL & (1)#4 AL GND. Oo J� 400A PANEL CONSTRU TRAILERS, SEE ONE-LI 1 � s �A r 112016 REVIEWED )h COMPLIANCE VVITI"I NFPA 70 a NEC JUN 2 2 2015 City ofTukwila WILDING DIVISION RECEIVED CITY OF TUKWILA JUN 15 2015 PERMIT CENTER ISSUE 0 Date Description 06.12-2015 SCALE: 1/16" =V-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE DRAFT CD'S PROJECT NUMBER GWA NO. PROJECT uj 3: Ow Y z O � w >g o� V QF- z CIO N N N V , SULTANT REGISTRATION G. 4. 'Es �r c�` o AS /15 aj GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 314 SEATTLE, WA 98103 PHONE: (206) 826.1447 FAX: (206) 8264446 SHEET TITLE AND NUMBER TEMP POWER ELECTRICAL SITE PLAN TEMP PWR#1 TO PUGET POWER SERVICE POINT LOAD CALC 800A SWITCHBOARD LOAD CALC 1600A SERVICE TEMP HEAT PLACING BOOM #1 (15 HP) PLACING BOOM #1 (15 HP) TOWER SKID FEEDER #1 TOWER SKID FEEDER #2 GARAGE SKID LARGEST MOTOR 25% OF 15 HP tilelr.L 120 KVA 17.5 KVA 17.5 KVA 225 KVA 225 KVA 30 KVA 4.37 KVA 639.97 KVA 0 480V 30 769 AMPS 800 AMP SWITCHBOARD MAN LIFT #1 (3) 30HP MAN LIFT #1 (3) 30HP TOWER CRANE 147HP HOIST 11OKW 14HP TROLLEY 10.5KW (3} 10HP SWING 22.5KW (4) 10HP TRAVELLING 30KW LARGEST MOTOR 25% OF 147HP 635 KVA (WITHOUT THE 4.37KVA LARGEST MOTOR LOAD FROM THE 800A SWITCHBOARD LOAD CALCULATION) 115 KVA 115 KVA 173 KVA 27.5 KVA TOTAL 1065.5 KVA 0 480V 30 1282 AMPS 800A 1600A n» /Annv -7 niiAc�r PLAN NOTES O1 (2) 8' GROUND ROD 10' APART. U2 GROUND PER CODE. FEEDER CALLOUTS 1360A 4"C, EA. W/(3)#600 KCM AL & (1) 250 KCM AL & �4) 1)#4/0 AL GND. I 120A O 1 1 /2"C, W/(4)#1 /0 AL & (1)#4 AL GND. I TEMP POWER ONE —LINE DIAGRAM SCALE: NONE 205A 0 2 1 /2"C, W/(4)250 KCM AL & (1)01 /0 AL GND. 31 OA ® (2)2"C, EA. W/(3)#3/0 AL & (1)#2 AL GND. 120A 0 1 1 /4"C, W/(3)#1 /0 AL & (1)#4 AL GND. 31 OA ©(2)2 "C, EA. W/(3)3/0 KCM AL & (1)#2 AL GND. 40A 0 3/4"C, W/(4)#8 AL & (1)#6 AL GND. 205A ® 2 1 /2"C, W/(2)250 KCM AL & (1)#1 /0 AL GND. 81 OA 9 &4"C. EA. W/(3)#500 KCM AL (1)250 KCM AL &�3) 1)#33/0 AL GND 90A Q 1 1 /4"C., W/(3)#2 AL & (1)#6 AL GND LEVEL 1 (CONSTRUCTION RECEPTACLE AND LIGHTING CIRCUITS) LEVEL 2 (CONSTRUCTION RECEPTACLE AND LIGHTING CIRCUITS) LEVEL 5 (CONSTRUCTION RECEPTACLE AND LIGHTING CIRCUITS) LEVEL 8 (CONSTRUCTION RECEPTACLE AND LIGHTING CIRCUITS) LEVEL 12 (CONSTRUCTION RECEPTACLE AND LIGHTING CIRCUITS) LEVEL 17 (CONSTRUCTION RECEPTACLE AND LIGHTING CIRCUITS) GARAGE SKID REVIEWELr ,, . COMPLIANCE ®MP 70� �9 Er NF JUN 2 2 2015 CityOf •TUKWIlaa.. ' RECEIVED CITY OF TUKWILA JUN 15 2015 ISSUE A Date Desc—dpfion 06-12-2015 SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE DRAFT CD'S PROJECT NUMBER GWA NO. PROJECT 0. W 3: O W Y Z IL 3: w �� p� �./ Q N Z M N N �Z V J CONSULTANT REGISTRATION M.q' ES F� z A /05/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 626444T FAX: (206) 82641446 SHEET TITLE AND NUMBER TEMP POWER ONE -LINE DIAGRAM TEMP PWR#2 91 PERMIT CENTER