Loading...
HomeMy WebLinkAboutPermit EL15-0525 - EDDIE BAUER - TENANT IMPROVEMENTEDDIE BAUER 660 SOUTHCENTER MALL EL15-0525 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 9202470010 Permit Number: EL15-0525 Address: 660 SOUTHCENTER MALL Issue Date: 2/19/2016 Permit Expires On: 8/17/2016 Project Name: EDDIE BAUER Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940, CARLSBAD, MI, 92013 Contact Person: Name: AMY DIEKEVERS Phone: (616) 493-9334 Address: 75 - 60TH ST SW, WYOMING, MI, 49548 Contractor: Name: CORRIDOR ELECTRIC INC Phone: (360) 862-8062 Address: 408 MAPLE AVE, SNOHOMISH, WA, 98290 License No: CORRIEI993117 Expiration Date: 12/27/2017 Lender: Name: Address: DESCRIPTION OF WORK: TENANT IMPROVEMENT Valuation of single family: $0.00 Fees Collected: $892.62 Valuation of mf/comm: $31,121.00 Type of Work: Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: v Arm( Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per 'i4-agree to the conditions attached to this permit. Signature. Date: -lam Print Name: ---,'L 1-i-C This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB iLA, why CITY OF TUKWILA o� Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 1908 f Tukwila, WA 98188 htto://www. ci. tukwila. wa. us Electrical Permit No. v M Project No. (For office use only) Wr�l ELECTRICAL PERMIT APPLICATIONXP V 5 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION I �O King Co Assessor's Tax No.: Site Address: M Suite Number: Z Floor: Tenant Name: eta New Tenant: ❑ .....Yes ❑ .. No Property Owners Name: Mailing Address: City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Mailin E-Mail Address: Q=" r " 1 a 9 U& i �'NU �. (0YV%_ Fax Number: to I La —V 9& '9_�24 ELECTRICAL CONTRACTOR INFORMATION --� Company Name: Mailing Address: �t7 J' City State Zip Contact Person: Day Telephone: E-Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ —?-,\ 4 Scope of Work (please provide detailed information):.S(�ck1.� M�Ci bi Will service be altered? ❑ Yes No Adding more than 50 amps? ❑ Yes No ellm "" Type of Use:(Qr C 1�11�T1 Type of work: ❑ New ❑ Addition ❑ Service Change Remodel W Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication l ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H9Applicalions\F-'otms-Applications On llneU-2009 - Electrical Permit Application.dec Page l of 2 bh RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $145.60 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $78.00 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $57.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $78.00 (no added/altered circuits) ❑ Service change with added/altered circuits.................$78.00 number of added circuits .......................$11.00 ea ❑ Circuits added/altered without service change ........... $52.00 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $52.00 (6 or more circuits) ............................................... $7.30 ea ❑ Meter/mast repair ....................................................... $65.00 ❑ Low voltage systems ................................................. $57.00 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $60.00 ❑ Temporary service (generator) ................................... $75.00 ❑ Manufactured/mobile home service ........................... $80.00 (excluding garage or outbuilding) ❑ Carnivals....................................................................$75.00 Number of concessions ......................... $10.00 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER R ELECTRICAL CONTRACTOR: Date: 6, -LA - — City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:\Applications\Fortes-Applications On Line\I-2009 - Electrical Permit Application.doc Page 2 of 2 bh DESCRIPTIONS PermitTRAK ACCOUNTQUANTITY PAID $727.32 EL15-0525 Address: 660 SOUTHCENTER MALL Apn: 9202470010 $727.32 ELECTRICAL $661.20 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $661.20 TECHNOLOGY FEE $66.12 TECHNOLOGY FEE R000.322.900.04.00 0.00 $33.06 TECHNOLOGY FEE TOTAL6.. R000.322.900.04.00 0.00 $33.06 Date Paid: Tuesday, February 16, 2016 Paid By: CASSNIK CONTRACTING LLC Pay Method: CHECK 003131 Printed: Tuesday, February 16, 2016 10:55 AM 1 of 1 p"fSYSTEMS DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,948.77 D15-0132 Address: 660 SOUTHCENTER MALL Apn: 9202470010 $1,678.69 DEVELOPMENT $1,678.69 PLAN CHECK FEE 11000.345.830.00.00 0.00 $1,678.69 EL15-0525 Address: 660 SOUTHCENTER MALL Apn: 9202470010 $165.30 ELECTRICAL $165.30 PLAN CHECK FEE R000.345.832.00.00 0.00 $165.30 M15-0071 Address: 660 SOUTHCENTER MALL Apn: 9202470010 $69.90 MECHANICAL $69.90 PLAN CHECK FEE R000.322.102.00.00 0.00 $69.90 PG15-0069 Address: 660 SOUTHCENTER MALL Apn: 9202470010 $34.88 PLUMBING $34.88 PLAN CHECK FEE TOTAL R000.322.103.00.00 0.00 $34.88 Date Paid: Tuesday, June 09, 2015 Paid By: PRECISION PERMIT Pay Method: CHECK 13465 Printed: Tuesday, June 09, 2015 1:03 PM 1 of 1 07W SY57EMS INSPECTION RECORD Retain a copy with permit ��� INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: !! �%b &A tG Type of Inspection: Address: 67, NZ Date Called: Special Instructions: t Date Wanted: a. .m. Requester: L Phone No: Z 7o �Z N./ Approved per applicable codes. E Corrections required prior to approval. Ur-qS I Aj� nspector: ate: El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 3 Retain a copy with permiejit ) INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection:, Address: Date Called: Special Instructions: Date Wanted: p• Requester: Phone No: Approved per applicable codes. 1-1 Corrections required prior to approval. COMMENTS: I �� (> 2-0 IInspector: � lj1-1 P Kb /f-V IDate: oio(o / j& REINSPECTION FEE REQUIRVD. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD / , Retain a copy with permits INSPECTION NO. PERMIT NO. , CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Ab1C � &� Type of Inspection: Address: 6 70 Date Called: Special Instructions Date Wanted: p.m Requester: Approved per applicable codes. E Corrections required prior, to approval. U paid at 6300 Southcenter Blvd.. Suite 100. Catt to schedule reinspection. INSPECTION RECORD Retain a copy with permit�� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: , 1 (WK Type of Inspectio .a Address: 6(0 q4v Date Called: Special Instructions: I Date Wanted: Requester: Phone No: r o u EDApproved per applicable codes. E Corrections required prior to approval. I Kn Ad- (r� �flflci� 03 REINSPECTION FEE REQUIRED. Prior to next inspection; fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD,--t Retain a copy with permit INSPEC11ON NO. PERMIT N0. CITY O TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line(206) 438-935 ProjectType L�'If" .I� ft�r.w a In on: Address, Date Called: ` Special Instructions. Date ante : a.m. p.m. quester: PhoneA; If NA w roved per applicable codes.Carrectians required prior to approval. r5aiRENTS. WHSPC t N FEIr �€�IRM. Prior to next inspection, fee must be perld # tout#icont+er Blvd. Suite 100. Cali, to schedule reinsrpection ►FA- RE %OV 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Info Project Address EDDIE BAUER Date 5/5/2015 Compliance forms do not SOUTHCENTER MALL For Building Department Use SEATLE, WA. require a password to use. Applicant Name: CALVIN.T CHHUOR Instructional and calculating cells Applicant Address: 1750 COMMERCE COURT WHITE BEAR LAKE MN.55110 are write- � Applicant Phone: 661-748-1100 Project Description ElNew Building ElAddition Alteration El Plans Included Lighting Compliance Path O Lighting Power Density Calculations Q Total Building Performance (if Total Building Performance then only LGT-CHK is required.) Lighting Power Allowance Method Selection required to Q Building Area Method QQ Space -By -Space Method enable LPA forms Interior Lighting System R EC E i'; E D Description CITY OF TUKWILA Briefly describe lighting 012015 ,JUN system type and features. PERMIT CENTER Additions and Change of Space Use•(C101.4.3 & C101.4.4) 121 Addition area or Change of Space Use area complies with all applicable provisions as stand alone project ❑ Addition area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions per C101.4.3 Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13,, Alterations, Renovations and Repairs (C101.4.3.1) ❑✓ 60% or more of luminaires in space replaced Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (L TG- INT-SPACE) CompQance Form. Document maximum allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Retrofit and non -retrofit spaces shall be documented separatdly using multiple forms. ❑ Less than 60% of luminaires in space replaced Provide a separate Space -By -Space Method (LTG-INT-SPACE) Compliance Form for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage table. :. ❑ Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased New wiring installed to serve added fixtures and/or fixtures relocated to new circuit w . Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2,3), and commissioning of lighting controls per C405.13 ❑ New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting 1"MSP%9405.13. S e- luminaires unchanged or moved only PLCM§ft 00Hb/ lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. A -96 o chVjFraire bein made to the interior lighting and space use not changed. JUN 2 4 2015 City of Tukwila BUILDING DIVISION_' t"l 0 W)C/ !1, 2012 Washington State Energy Code Compliance Forms for Commercial Buildinas inch,dinn R9 x Rs nvar a ttAriac —i �u o1 Project Address EDDIE BAUER Date 5/5/2015 Lighting Alterations, Renovations & Building Additions For Building Department Use O Less than 60% 60% or more O Stand alone O Addition ote . L-- hti g fix' re s i a wilding a diti0n may comply as a stand alone project, or they maybe combs ad h tip oerall ezis ng b/dg lighting to demonstrate compliance. Refer to C101.4.3. b. or re fits aat) sliding addit%One, provide Space Types and gross interior areas in the aximum (lowed Lighting table. if a builidng addition will comply as combined with the overall existing builidng, include all applicable existing Space Types and gross interior areas c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 60% of existing fixtures will be replaced, provide total existing lighting wattage (prior to retrofit) in the space provided in the Maximum Allowed Lighting table. Specify Compliance .Method on LGT-SUM Location (plan #, owe rose Interior WAs owe room #) Space Type* Watts per ft2 Area in ft2 (watts/ft2 x area) SALES AREA Retail: Sales area 1.68 3205 5384 STOCKROOM, Storage , — 0.63 588 370 TOILET ROOM Restioom 0.98 62 61 Atrium" Enter Height: Existing Lighting Enter Exist Watts: DISPLAY Retail Display Allowance from LTG-iNT-DISPLAY 552 " Select Table C405.5.2(2) category from drop down menu. ** For atriums, indicate height. Allowed wattage for first 40 feet is 0.03 W/Yt. ht , above 40 feet is 0.02 W/ft. ht. Specify Compliance Method on LGT-SUM Area Allowed Watts Total 3855 6368 Location (plan #, room #) Fixture Description``* Number of Fixtures Watts/ Fixture Watts Proposed SALES AREA TYPE F2 TRACK WITH 2A CURRENT LIMITING 192 SALES AREA TYPE F2 TRACK WITH 4A CURRENT LIMITING 1 384 384 SALES AREA TYPE F2 TRACK WITH 10A CURRENT LIMITING 3 960 2880 SALES AREA TYPE F2 TRACK WITH 12A CURRENT LIMITING 1 1152 1152 SALES AREA TYPE E 90 STOCKROOM TYPEDIDD 14 58 812 TOILET ROOM TYPE J 1 120 120 Retail Display Lighting from LTG-INT-DISPLAY 552 Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Wattl 5 900 *" Include existing to remain lighting fixtures and exempt lighting equipment per notes below. Notes: 1, Include ALL proposed lighting fixtures, 2. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type 0f included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 3. For proposed Watts✓Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. 4. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 5. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description 6, If #NA appears in Retail Display cells, information on L TG-INT-DISPLA Y is incomplete. (Interior Lighting Power Allowance Building Area Method Selected. Use LTG-INT-BLD, t 2012 Washington State Energy Code Compliance Forms for Commercial Buildlnns includinn R9 R Rs nvAr q c,nric nn l "u rs, o Project ITlfO � .Project Address EDDIE BAUER Date 5/5/2015 SOUTHCENTER MALL For Building Department Use SEATLE, WA. Applicant Name: CALVIN.T CHHUOR Specify Compliance Method on LGT-SUM Location (plan #, room #) Retail Display Area Type* owe _ Watts per ftz ** Gross n enor Area in ft2 Wat s owe (watts/ft2 x area) DISPLAY Retail 3: Furniture, clothing, cosmetics, artwork 1.40 500 700 * Only retail sales areas that meet the requirements defined in Table C405.5.2(2) Area Area Watts footnote A may be entered here. Select retail sales areas form drop down menu. Total 500 700 Wattages per Table C405,5,2(2) footnote A. ++ Display light allowance per footnote A calculation. Display Lighting Base Allowance 500 ++ Total Display Allowance 1200 Specify Compliance Method on l...GT-SUM Oi)lir SEpafatelit controlled disnlav fixtures indr npnrfnnt of nnnraral anon rtni,ti,,,, „— T.M. rangy n . ..... _._ Display Area* Location (plan #, room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Retail 3 SALES AREA TRACK 2A CURRENT LIMITING 1 192 192 Retail 3 SALES AREA TYPE "E" 4 90 360 . —u- icier sates urspiay area from drop down menu. Total Proposed WattsL 552 r-- Proposed Display Retail t Retail Retail 3 Retail Lighting Totals 552 Notes: 1. Forproposed Display Fixture Description, indicate fixture type, lamp type (e.g. T-B), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5,1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all display fixtures. • City of Tukwila Jim Haggerton, Mayor • Department of Community Development Jack Pace, Director December 1, 2015 Amy Diekevers Precision Permit Services 75 60`h St SW Wyoming, MI 49548 RE: Request for Application Extension Eddie Bauer— 660 Southcenter Mall Dear Ms. Diekevers, This letter is in response to your written request for an extension to Application Number EL15-0525. The Building Official has reviewed your letter and considered your request to extend the above referenced application. It has been determined that the City of Tukwila Building Division will be extending your permit application an additional 180 days, through June 9, 2016. If you should have any questions, please contact our office at (206) 431-3670 extension 1. Sincerely, Bill Rambo Permit Technician File: Permit EL15-0525 WAPertnit CenteAExtension Letters\Applications\2015\EL15-0525App Extension Letter. docx 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Bill Rambo From: Amy Diekevers <amyd@precisionpermits.com> Sent: Friday, November 20, 2015 11:05 AM To: Bill Rambo Subject: Request for Plan Review Extensions EDDIE BAUER SOUTHCENTER Attachments: EL15-0525.pdf; PG15-0069.pdf; M15-0071.pdf; D15-0132.pdf Importance: High Per the attached notices, I am requesting plan review approval extensions on all of them. We are scheduled to start construction on 2/ 1/ 16. Let me know if this is enough to extend the approvals or if there is something additional I need to do. Thant? you, Precision Permit Services 75 60th St SW V✓yoniing MI 49548 616-493-9334 ph 616-493-9351 fax Request for Extension # Current Expiration bate: Extension Request: Approved for ORO days Y ❑ Denied (provide explanation) Signature/Initials f 1 City of Tukwila � Jim Haggerton, Mayor Department of Community Development Jack Pace, Director November 4, 2015 AMY DIEKEVERS 75 60TH ST SW WYOMING, MI 49548 RE: Application No. EL15-0525 EDDIE BAUER 660 SOUTHCENTER MALL Dear AMY DIEKEVERS: Permit application EL15-0525 for the work proposed at EDDIE BAUER (660 SOUTHCENTER MALL) has not been issued by the City of Tukwila Permit Center. Per the International Building, Residential, and Mechanical Codes as well as the Uniform Plumbing Code and/or the National Electric Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire 12/09/2015. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is completed for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that your permit is not issued, we do not receive your written request for extension, or your request is denied your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, � I Bill Rambo Permit Technician File No: ELI5-0525 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 * Phone 206-431-3670 • Fax 206-431-3665 . s'RMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0525 DATE: 06/15/15 PROJECT NAME: EDDIE BAUER SITE ADDRESS: 660 SOUTHCENTER MALL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: �! .W (- - �-� s- Building Division Fire Prevention Planning Division Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 06/16/15 Not Applicable ❑ Structural Review Required ❑ (no approval review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/14/2015 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 CORRIDOR ELECTRIC INC Page 1 of 3 Home Espanol Contact. Safety & Health (3 Washington State Department of Labor & Industries CORRIDOR ELECTRIC INC Search L&I � ��rr A-'L IndeA Help My Secure I,&I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 408 MAPLE AVENUE SNOHOMISH, WA98290 Principals 360-862-8062 BERGMAN, STEVEN P, PRESIDENT SNOHOMISH County Bergman, Terri A, VICE PRESIDENT BERGMAN, STEVEN P, AGENT BERGMAN, STEVEN P, VICE PRESIDENT (End: 02/25/2011) Doing business as CORRIDOR ELECTRIC INC WA UBI No. Business type 602 165 975 Corporation Governing persons STEVEN PETER BERGMAN TERRI ANN BERGMAN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. .......................................................... . Meets current requirements. License specialties GENERAL License no. CORRIE1993R7 Effective — expiration 12/27/2001-12/27/2017 Designated administrator BERGMAN, STEVEN P License type Master Electrician Bond American Contractors Indem CO Bond account no. 100170133 Received by L&I 09/21/2011 Bond history Savings Savings history Active. Meets current requirements. License no. BERGMSP965DD $4,000.00 Effective date 07/18/2011 Expiration date Until Canceled 'Ms-oR9)- la-1-7 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602165975&LIC=CORRIE1993R7&SAW= 2/19/2016 U # O25 24 J s 27 1�IKP z1 1z PANEL LA - OPANEL 0 P LA-24 32 ® F( ACP� LB-13 El LA-33 LA-39 LA-35 N DO NOT PLACE ANYTHING ON THE BACKWRAP WALL EXCEPT BACKWRAP EQUIPMENT. 83- 1 /4" = 1'-0" 40-1" 72—i" 1 60-1j" NITS LA-37 LA-33 40—J' :, e ;, is gl 1, • GENERAL NOTES A. CONTRACTOR SHALL COMPLETELY REMOVE ALL EQUIPMENT, PANELBOARDS, DEVICES, FIXTURES, WIRING, CONDUIT, ETC. AND ALL ASSOCIATED SUPPORTS, BRACING, PADS, ETC. NOT BEING REUSED OR SHOWN TO REMAIN WHETHER IN THE DEMISED SPACE, ON THE ROOF OR OTHERWISE LOCATED OUTSIDE OF THE DEMISED SPACE. DO NOT ABANDON IN PLACE. B. ALL 120 VOLT BRANCH CIRCUITS IN EXCESS OF 75' SHALL HAVE CONDUCTOR SIZE INCREASED A MINIMUM OF 1 CONDUCTOR SIZE. INSTALLING CONTRACTOR SHALL DETERMINE ACTUAL CONDUCTOR SIZE TO BE INSTALLED TO ADHERE TO VOLTAGE DROP REQUIREMENTS. C. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR ALL DEVICE LOCATIONS PRIOR TO ROUGH -IN. FIELD COORDINATE WITH OWNERS REPRESENTATIVE. D. REFER TO SHEET E4 FOR ELECTRICAL SYMBOL LEGEND. E. PAINT ALL EXPOSED ELECTRICAL CONDUIT, JUNCTION BOXES, CONNECTORS, WIRE, LIGHT FIXTURE SUPPORT RODS/CHAINS, EQUIPMENT SUPPORT ROD/CHAINS, PLATFORMS, ETC. COLORS AS INDICATED ON ARCHITECTURAL REFLECTED CEILING PLAN TO MATCH CEILING. F. ADD A BLANK COVER PLATE TO ALL OPEN J-BOXES AFTER A/V AND COMMUNICATION SYSTEMS INSTALLATION IS COMPLETE. LA-39 .......... _... _....... _. ................ 28 ii -- I A.F.F. LA-10-\ LA-10-, Kf•1 :r-i;vsiT �a �12ZED FOR: l F.I b.lia lical 0-Electrical IfPiumbing [Zocas PVmg of Tukwffa ; .3 DfVDS30'Ni FILE CORI Permit Me. _h S_ ft. 0 S�Ar Plan review approval is subject to c. rors and orni:;&71ons. Appiraval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy d conditions is acknowledged: B. . Date: City of Tukwila BUILDING DIVISION REV►Sl4NS No changes shall be made to the scope t71 Wvork f' 11ou€t prior to of }"� Division. �� rila Building stun. ;a;;uire a near El to may inc'::de d �' plan submittal2,�d?banal plan r2�ri^t}r fuss. KEY NOTES THIS DRAWING REVIEWED.FOR COMPLIANCE WITH NFPA 70 - NEC JUN 2 4 2015 City oflulwila BUILDING DIVISION O1 ELECTRICAL EQUIPMENT LOCATION. REFER TO ELECTRICAL PANEL SCHEDULES 18 AT PROCESSING COUNTER IN STOCK ROOM PROVIDE:. AND POWER RISER DIAGRAM ON SHEET E3 FOR FURTHER INFORMATION. 2)DUPLEX RECEPTACLES AT 49" A.F.F., EACH WITH ITS OWN DEDICATED CIRCUIT. 1 FOURPLEX CONVENIENCE RECEPTACLE AT 49" A.F.F. O2 FOR VIDEO ARRAY AT FOCAL WALL, PROVIDE (2) RECESSED QUAD RECEPTACLES 1PHONE ROUGH —IN FOR MODEM AT 49" A.F.F. — EXTEND 3/4" CONDUIT FROM AND (1) 4x4x2 BOX WITH SINGLE GANG MUD RING FOR LOW VOLTAGE CABLING. ROUGH —IN TO HIGH ON WALL. PROVIDE A SEPARATE DEDICATED 120V CIRCUIT FOR EACH QUAD RECEPTACLE (2 (1)ROUGH—IN FOR WALL PHONE AT 60" A.F.F. — EXTEND 3/4" CONDUIT FROM TOTAL). REFER TO DETAIL 3 THIS SHEET FOR MOUNTING HEIGHTS. ROUGH —IN TO HIGH ON WALL. O3 PROVIDE 1 1/4" EMPTY CONDUIT WITH PULLSTRING TO BACKBOARD AT 19 PROVIDE ROUGH —IN AND FINAL CONNECTION TO 120V HAND DRYER. COORDINATE DATA/EQUIPMENT RACK FOR DATA LINE. EXACT LOCATION PRIOR TO ROUGH —IN. O4 ELECTRICAL CONTRACTOR TO PROVIDE 1" EMPTY CONDUIT AND PULLSTRING TO 20 EXISTING 120V, 1.5 KW WATER HEATER LOCATED ABOVE TOILET ROOM TO REMAIN. BACKBOARD AT DATA/EQUIPMENT RACK FOR CASH WRAP TELEPHONE AND VERIFY EXACT LOCATION. DATACOMM. 21 CONTRACTOR SHALL MAKE ARRANGEMENTS WITH LANDLORD FOR INSTALLATION OF O5 CHANNEL FLOOR FOR NEW CONDUITS, STUB UP BENEATH CASH WRAP DESK. TELEPHONE BOARD. CONTACT LOCAL UTILITY FOR SERVICE. TELEPHONE ROUTING SHOWN FOR REFERENCE ONLY. ROUTE CONDUITS VIA THE SHORTEST EQUIPMENT SHALL BE INSTALLED BY COMMUNICATIONS SUB —CONTRACTOR. REUSE PATH POSSIBLE. EXISTING IF APPLICABLE. O6 AT EACH LOCATION NOTED AT CASH WRAP DESK PROVIDE: 9> PROVIDE NEW TIME CLOCK AND CONTACTORS. REFER TO SHEET E2 FOR (1)DEDICATED GROUND DUPLEX RECEPTACLE FOR P.O.S. TERMINALS, CIRCUIT AS FURTHER INFORMATION AND DETAIL 5/E3. INDICATED. �1�CONVENIENCE DUPLEX RECEPTACLE, CIRCUIT AS INDICATED. INSTALL DOOR BUZZER SIGNALING DEVICE AND LV TRANSFORMER AT 7'-6" 123SINGLE GANG BOX FOR TELEPHONE AND DATACOMM. ABOVE STOCK FLOOR. CONNECT TO STOCK RECEPTACLE CIRCUIT. INSTALL DOOR CONDUIT FOR POWER AND COMMUNICATION CABLING TO RECEPTACLES AND BUZZER RECESSED IN WALL NEAR REAR DOOR. TECHNOLOGY DEVICES TO BE ROUTED ON FLOOR BENEATH CASH WRAP DESK. <24> PROVIDE DOOR BUZZER PUSH BUTTON AT 48" A.F.F.. EXTEND BELL WIRE IN O7 INSTALL DOOR BUZZER 11'-6" OFF CASH WRAP CABINET FACE AND EXTEND BELL 3/4" CONDUIT TO SIGNALING TRANSFORMER IN STOCKROOM. SEE DETAIL 2 ON WIRE TO SIGNALING TRANSFORMER CALLED OUT IN KEY NOTE #26. SEE DETAIL SHEET E3. 2 ON SHEET E3. 25 LOCATION OF BATTERY POWERED DETEX. FURNISHED BY OWNER, INSTALLED BY < PROVIDE ROUGH —IN FOR SECURITY CONTACT AT BASE OF DOOR. EXTEND 3/4" CONTRACTOR. CONDUIT FROM CONTACTOR LOCATION AND STUB OUT HIGH ON WALL. VERIFY EXACT ROUGH —IN REQUIREMENTS PRIOR TO COMMENCING ANY WORK. 26 PROVIDE ROUGH —IN FOR SECURITY DOOR SWITCH CONNECTION AT HEAD OF DOOR ON STRIKE SIDE OF DOOR AND STUB OUT HIGH ON WALL. VERIFY EXACT O9 FOR SHOPPERTRAK: LOCATE J—BOX 1'—O" FROM ENTRY CENTERED ON DOOR ROUGH —IN REQUIREMENTS PRIOR TO COMMENCING ANY WORK. WITH A CAT 5, 4 PAIR PLENUM RATED CABLE FROM J—BOX TO THE EQUIPMENT RACK WITH 20" OF CABLE COILED AT BOTH ENDS. 27 PROVIDE ROUGH —IN AT 48" A.F.F. FOR SECURITY SYSTEM KEYPAD. EXTEND 3/4" CONDUIT HIGH ON WALL. KEYPAD SHALL BE INSTALLED BY SECURITY SYSTEM 10 LOCATION OF SECURITY ALARM HORN — FURNISHED AND INSTALLED BY OWNERS SUB —CONTRACTOR. VERIFY EXACT ROUGH —IN REQUIREMENTS PRIOR TO SUB —CONTRACTOR. INDICATED HERE FOR REFERENCE ONLY. COMMENCING ANY WORK. 11 LOCATION OF DIRECTIONAL INFRARED MOTION DETECTOR FURNISHED AND <0>PROVIDE PHONE JACK AND SINGLE GANG BOX AT 50-1/2" A.F.F.. INSTALLED BY OWNERS SUB —CONTRACTOR. PROVIDE SINGLE GANG BOX WITH COVERPLATE AND EXTEND 3/4" CONDUIT TO VICINITY OF DATA EQUIPMENT IN 29 EXISTING HVAC UNITS (FCU—EX-1 & HP—EX-1), 480V/30, TO REMAIN. MAINTAIN OFFICE. VERIFY EXACT ROUGH —IN REQUIREMENTS PRIOR TO COMMENCING ANY EXISTING FEEDERS AND CIRCUITING. VERIFY EXACT LOCATION WITH MECHANICAL WORK * 12 PROVIDE WALL MOUNTED DUPLEX RECEPTACLE 6" ABOVE SHOW WINDOW. COLOR CONTRACTOR. RE:;EiVED TO MATCH ADJACENT SURFACE. ROUTE CIRCUIT VIA CONTACTOR C3. 30 NOT USED. Ci T Y OF TUKW LA 13 EQUIPMENT RACK LOCATION. REFER TO 1/E3 FOR FURTHER INFORMATION. JUN -9-9 201 31 NOT USED. 14 PROVIDE FLUSH MOUNTED SINGLE GANG BOX WITH COVER AT 9'-0" A.F.F. FOR PERMIT CENTER OWNER SUPPLIED STOCKROOM SPEAKER. PROVIDE SINGLE GANG BOX WITH 32 PROVIDE FIRE ALARM DEVICES AS INDICATED AND CONNECT TO LANDLORDS FIRE COVER AT 48" A.F.F. FOR OWNER SUPPLIED VOLUME CONTROL FOR STOCKROOM ALARM SYSTEM. COORDINATE EXACT REQUIREMENTS WITH LANDLORD FIRE ALARM SPEAKER. PROVIDE 3/4" CONDUIT FOR CONTROL WIRE FROM VOLUME CONTROL CONTRACTOR PRIOR TO BID AND INSTALLATION. REUSE/RELOCATE EXISTING LOCATION TO WALL MOUNTED SPEAKER. DEVICES IF APPLICABLE. FIRE ALARM DEVICE LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL LOCATIONS NEED TO BE INSTALLED PER CODE AND 15 NOT USED. ARE THE RESPONSIBILITY OF THE CONTRACTOR INSTALLING IT. 16 NOT USED. 17 AT BREAK COUNTER PROVIDE: (1)DUPLEX RECEPTACLE AT 15" A.F.F. FOR REFRIGERATOR. 1 DUPLEX RECEPTACLE AT 40" A.F.F. FOR MICROWAVE. REFER TO BREAK COUNTER DETAIL ON SHEET A11 FOR EXACT LOCATION OF DEVICES. 61 I:II�I�7� PANEL LB PANEL LB I91 1 ic. W.oIll— D [ LA-23cI I LA- LA-13 F2 14) LA-13 LA-5 / ��j is wLA-1I I " EM " 5 LA-1 O F LS) 1� F L7) LA-11 LA-11 w w u TYP. LA-5 F2L0, - 10A 5 F L8) LA-5 t,-n F?L6) LA-11 G 11 LA-15 0 LA-7 FZL7) 10A V FLA 8) LA-7 -...__....... (PLEASE DON' T FORGET TO INCLUDE THIS REV70 LAYER WITH NEXT REVISION) w 11Y �tf LA-9 F L8) F L8) LA-11 LA-11 TYP. DO NOT PLACE ANYTHING ON THE BACKWRAP WALL EXCEPT BACKWRAP EQUIPMENT. NOTE: FEEDER CONDUCTORS SHALL BE SIZED FOR A MAXIMUM VOLTAGE DROP OF 2 PERCENT AT DESIGN LOAD. BRANCH CIRCUIT CONDUCTORS MUST BE SIZED FOR A MAXIMUM VOLTAGE DROP OF 3 PERCENT AT DESIGN LOAD. CIRCUIT IDENTIFICATION XX FIXTURE TYPE R-5c PANEL & CIRCUIT NUMBER C2f CONTACTOR NUMBER SWITCH CONTROL CURRENT LIMITING DEVICE SCHEDULE TAG LIGHTOLIER CATALOG # DESCRIPTION WATT RATING 80% MAX LOAD 2A PLD240WH 2A CURRENT LIMITING DEVICE 240W 192W 4A PLD480WH 4A CURRENT LIMITING DEVICE 48OW 384W 10A I PLD1200WH 10A CURRENT LIMITING DEVICE 120OW 960W INSTALLED FIXTURE WATTAGE IS NOT TO EXCEED 80% OF CURRENT LIMITER RATING. CONTACTOR SCHEDULE MARK AREA CONTROL COIL LINE POLE AMP CIRCUITS CONTROLLED C1 PERIMETER SWITCH a 120 120 8 20 LA-5,7,13,29 TRACK C2 SALES AREA SWITCH b 120 120 6 20 LA-9,11 GENERAL C3 I STOREFRONT TIME CLOCK 120 120 6 20 LA-3,17,25,27 1 /4„ = 1'-011 F�8) LA-9 F�8) LA-9 1 F2L8) F L8) LA-9 rF�6) LA-9 A-9ir G 0 <8> LA-15 I F L7) v-7 LA-7 LA-3 Y `'� I� .2A' OV EM V LA-1 F2C10) I LA-5 3 l a F L8) 3: •a LA-9 d F25) I -.. .... XRLA-1 j LA-17 , CJ �. 0 • LA �3 I ...._l ................. LA-3 LK 1 F�8) LA-7 I OEM LA-1 _...................._._...................-......._........................ __.__......... __ ........ ,, LIGHTFIXTURE SCHEDULE PLAN MARK LOCATION' DESCRIPTION MANUFACTURER CATALOG# VOLTAGE PHILIPS LAMP DATA MOUNTING. REMARKS FURN. BY TYPE WATT NO. MODEL NO. LOCATION TYPE CHAIN HUNG W FLUOR WLM 76-4-232-QS-EB2- CHAIN D STOCKROOM WILLIAMS 12a, FLUOR 32 2 F32T8/TL830 CEILING EB WITH SOLID REFECTORS AD-BD-UNV HUNG -- CHAIN HUNG W FLUOR WITH SOLID REFECTORS CHAIN. DD STOCKROOM WILLIAMS 120 FLUOR 32 2 F32T8/TL830 CEILING EB AND EMERGENCY WLM76-4-232-EB2-AD HUNG BATTERY BALLAST BD-UNV-EM1400 -- RETAIL/3WAY CALCULITE8242HU- COMPACT PLT42W/830/ E RECESSED CAN LIGHT LIGHTOLIER 120 CEILING RECESSED EB MIRROR ADV/8038 CLWCCLW FLUOR 42 2 4P -- GIMBAL RING TRACK TRACK HUNG F2 RETAIL LIGHTOLIER 9022 BLACK 120 LED 19 1 PAR38 FROM, TRACK EB HEAD CEILING -- G RETAIL PENDANT CYLI NDER WILLIAMS PVC90-142T-BLK-CS- 120 COMPACT 42 1 CEILING STEM EB PM-EB9-UNV FLUOR -- TP-U-R-B-EM-EXIT, X THRU OUT EXITSIGN ASTRALITE UNIVERSAL 120 LED WITH UNIT SURFACE EB STORE W/CANOPY, 2 CEILING/ DIFFUSERS WALL -- 1 OFFICEAND 2X2 SURFACE MOUNTED LIGHTOLIER PNB2SRAVA3FT 120 -- 40 3 PLL40W/30/R5 CEILING- SURFACE EB TOILET 120X3CU L -- EM SALES THERMOPLASTIC LITHONIA ELM2 120 INCAND; 5.4 2 WITH UNIT CEILING PENDANT' EB; EMERGENCY LIGHT -- GENERAL NOTES A. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LIGHT FIXTURE LOCATIONS AND HEIGHTS. B. SEE SHEET E-1 FOR PANELBOARD LOCATIONS. C. SEE SHEET E-3 FOR PANELBOARD SCHEDULES. D. REFER TO CONTACTOR SCHEDULE FOR CIRCUITS BEING CONTROLLED. E. EXPOSED FLUORESCENT LAMPS SHALL HAVE TUBE GUARDS TS81252 4' T8 TUBE GUARD, FOIC. F. ALL LINEAR FLUORESCENT LIGHT FIXTURES SHALL BE INSTALLED TO MEET THE REQUIREMENTS OF NEC SECTION 410-13OG REGARDING LOCAL DISCONNECTING MEANS. G. ALL 120 VOLT BRANCH CIRCUITS IN EXCESS OF 75' SHALL HAVE CONDUCTOR SIZE INCREASED A MINIMUM OF 1 CONDUCTOR SIZE. INSTALLING CONTRACTOR SHALL DETERMINE ACTUAL CONDUCTOR SIZE TO BE INSTALLED TO ADHERE TO VOLTAGE DROP REQUIREMENTS. H. TO MAINTAIN POLARITY, STARTER TRACK IS TO BE DISASSEMBLED AND COMPONENT END FEED AND/OR DEAD END COVERS ARE TO BE INSTALLED ELSEWHERE ALONG RUN OF TRACK. UNUSED COMPONENTS ARE TO BE DISCARDED. MINIMUM EMERGENCY ILLUMINATION SHALL BE PROVIDED FOR A PERIOD OF 1.5 HOURS IN THE EVENT OF FAILURE OF NORMAL LIGHTING, WITHIN THE WORK AREAS. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOTCANDLE MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. FBC2007 1006, I. T1006 EXISTING FBC2007 705.7.1. J. ELECTRICAL OUTLETS OR BOXES SHALL NOT REDUCE THE FIRE RESISTANCE RATING OF FIRE RESISTANCE RATED WALL(S) AND SHALL COMPLY WITH FBC2007 712.3.2.. K. PLANS MUST BE DESIGNED IN ACCORDANCE WITH THE 2011 NATIONAL ELECTRIC CODE. L. PROVIDE SEISMIC BRACING AS REQUIRED FOR ALL SUSPENDED/LAY-IN LIGHT FIXTURES. M. PAINT ALL EXPOSED ELECTRICAL CONDUIT, JUNCTION BOXES, CONNECTORS, WIRE, LIGHT FIXTURE SUPPORT RODS/CHAINS, EQUIPMENT SUPPORT ROD/CHAINS, PLATFORMS, ETC. COLORS AS INDICATED ON ARCHITECTURAL REFLECTED CEILING PLAN TO MATCH CEILING. N. ADD A BLANK COVER PLATE TO ALL OPEN J-BOXES AFTER A/V AND COMMUNICATION SYSTEMS INSTALLATION IS COMPLETE. KEY NOTES THIS DRAWING O1 ELECTRICAL EQUIPMENT LOCATION. REFER TO ELECTRICAL PANEL SCHEDULES AND POWER RISER DIAGRAM ON SHEET E3 FOR FURTHER INFORMATION. O2 PROVIDE J-BOX. AND DISCONNECTING MEANS FOR STOREFRONT SIGNAGE. ROUTE SIGN CIRCUIT VIA THE TIME CLOCK. COORDINATE SCHEDULING WITH LANDLORD. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH ARCHITECTURAL SHEETS. 3O CIRCUIT SHOW WINDOW DOWNLIGHTS VIA TIME CLOCK LOCATED ADJACENT TO PANELS IN STOCK ROOM. COORDINATE SCHEDULING WITH LANDLORD. REVIEWED FOR OCURRENT LIMITING END FEED. NUMBER REPRESENTS AMP RATING OF DEVICE. COMPLIANCE WITH REFER TO CURRENT LIMITING DEVICE SCHEDULE FOR MORE INFORMATION. N PA 70 ® NEC O MOUNT THE BOTTOM OF THIS FIXTURE 4" ABOVE ADJACENT LIGHT FIXTURES. JUN 24 2015 OPROVIDE MULTIPOLE LIGHTING CONTACTORS (C1, C2 AND C3) FOR SALES AREA LIGHTING AND STOREFRONT LIGHTING AND RECEPTACLES. CONTACTORS C1 AND C2 SHALL BE CONTROLLED BY WALL SWITCHES (a & b) LOCATED ADJACENT TO City ®f llukWfl� SALES/STOCK DOOR. SWITCHES SHALL BE APPROPRIATELY LABELED "PERIMETER TRACK" AND "SALES TRACK", AND BE GANGED UNDER ONE COVERPLATE. BUILDING DIVISION CONTACTOR C3 SHALL BE CONTROLLED BY THE TIME CLOCK. REFER TO CONTACTOR SCHEDULE THIS SHEET AND LIGHTING CONTROL DIAGRAM ON SHEET E3 FOR FURTHER INFORMATION. O7 PROVIDE TIMECLOCK FOR MASTER CONTROL OF CONTACTORS C1, C2 AND C3. RECEIVED COORDINATE SETTINGS WITH STORE OPERATIONS. CITY OF TUKWILA 8O PROVIDE MANUAL OVERRIDE SWITCH (OR) FOR MASTER CONTROL OF TIME CLOCK SUN (g 2015 AND CONTACTORS. SWITCH SHALL BE A TIMED OVERRIDE TYPE. MAXIMUM TIME SETTING OF FOUR (4) HOURS. PERMIT CENTER O9 PROVIDE CEILING MOUNTED OCCUPANCY SENSOR APPROPRIATE FOR CIRCUITING AND SPACE USE. PROVIDE REQUIRED POWER SUPPLIES, RELAYS, ETC. FOR A COMPLETE INSTALLATION. IN TOILET ROOMS, SENSOR SHALL CONTROL LIGHTING AND EXHAUST FANS. 10 CONNECT EXIT ;AND EMERGENCY FIXTURES IN STOCK AREA TO SAME CIRCUIT AS GENERAL LIGHTING AHEAD OF LOCAL SWITCHING.IN ACCORDANCE WITH $THE N.E.C. 11 MOUNT THE BOTTOM OF THIS FIXTURE 13'-0" ABO 917SHED OOR Af \Gw 77 HEI Project No: R 1 5-2 1 24.01 3 (ARCHITECT'................. f� Z N L Q m Y M �J Of W O m p, dl n 0 0 t 0 n,,z-�L2 W ry CO 6. coj W Z W O1 J J �v E 00 C C.. U LO 2W FET T t, 0- NVAS�l� a4Q50 f�'o�, �clsT>✓fi�� �w� (0, A11,, 1 EXPIRES LL Review Set Issued: 05/OG/201 5 Permit Set Issued: 05/2G/201 5 Bid Set Issued: 05/2G/201 5 Construction Set Issued: Revisions No.: Date: A 0 drawn by: CTC Sheet Title LIGHTING PLAN Sheet No. ELECTRICAL SPECIFICATIONS NOTE: MANUFACTURER'S NAMES ON WHICH THIS SPECIFICATION IS BASED INDICATE THE MINIMUM QUALITY OF PRODUCT REQUIRED. SUBSTITUTION MAY BE MADE TO THOSE SPECIFIED IF DEEMED EQUIVALENT BY THE OWNER'S REPRESENTATIVE. ALL WORK AND PRODUCTS SHALL MEET THE REQUIREMENTS OF THE LANDLORD. 1. THE GENERAL CONDITIONS AND SUPPLEMENTARY GENERAL CONDITIONS SHALL BE CONSIDERED AS PART OF THIS SPECIFICATION. 2. ALL WORK TO BE IN ACCORDANCE WITH THE RULES AND REGULATION OF THE LOCAL AUTHORITIES HAVING JURISDICTION AND THE MOST RECENT EDITION OF NATIONAL ELECTRIC CODE. 3. CONTRACTOR SHALL FILE PLANS WITH AND OBTAIN APPROVALS FROM MUNICIPAL AGENCIES. ALL PERMITS AND CERTIFICATES OF INSPECTION SHALL BE OBTAINED AND PAID FOR BY THE CONTRACTOR. PERTINENT CERTIFICATES. SHALL BE DELIVERED TO THE OWNER'S REPRESENTATIVE, PRIOR TO FINAL BILLING. 4. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. HE SHALL CAREFULLY EXAMINE THE EXISTING CONDITIONS AND LIMITATIONS THEREOF. HE SHALL ASCERTAIN CONDITIONS UNDER WHICH THE WORK `, MUST BE PERFORMED, INCLUDING THE HANDLING OF MATERIALS, SECURITY AND LIMITING FIELD DIMENSIONS. FURTHER, THIS CONTRACTOR SHALL PROVIDE FIELD VERIFICATION OF LOCATION OF THE POINTS OF CONNECTION TO LANDLORD'S ELECTRICAL AND TELEPHONE EQUIPMENT AND DISTANCE FROM LEASED SPACE. ANY DISCREPANCIES WITH THE CONSTRUCTION DOCUMENTS DISCOVERED AS A RESULT OF THE AFOREMENTIONED FIELD SURVEY, SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE, PRIOR TO COMMENCING ANY WORK. ANY ADDITIONAL COSTS RESULTING FROM CONTRACTOR'S FAILURE TO DO SO SHALL BE THIS RESPONSIBILITY AND SHALL BE BORNE BY HIM. 5. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS THE JOB PROGRESSES; AN ACCURATE RECORD OF ALL WORK AS ACTUALLY INSTALLED. UPON COMPLETION OF THE WORK AND BEFORE FINAL PAYMENT IS AUTHORIZED, SHALL TURN OVER TO THE OWNER'S REPRESENTATIVE A RECORD SET OF PRINTS SHOWING THESE CHANGES. 6. SUBMIT MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE OWNER'S REPRESENTATIVE FOR REVIEW. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND SHALL BEAR THE STAMP OF THE ELECTRICAL CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE OWNER. 7. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING PATCHING REQUIRED FOR ANY WORK HEREIN SPECIFIED. ANY CUTTING SHALL HAVE PRIOR APPROVAL BY THE LANDLORD. ALL OPENINGS THROUGH STRUCTURALLY SUPPORTED SLABS MUST BE CORE BORED, SLEEVED, GROUTED, SEALED AND MADE WATERPROOF. SLEEVES MUST EXTEND AT LEAST 2" AFF. WATER PROOFING MUST BE INSPECTED AND APPROVED BY THE LANDLORD BEFORE ANY FLOORING MATERIAL IS INSTALLED. CONTRACTOR IS RESPONSIBLE TO TAKE WHATEVER MEASURES ARE NECESSARY, INCLUDING BUT NOT LIMITED TO THOSE MEASURES PRESCRIBED BY THE LANDLORD IN THE EXERCISE OF ITS REASONABLE JUDGMENT TO ASSURE THAT CORE BORING WILL NOT DAMAGE LANDLORD'S STRUCTURE, CONDUITS, ETC. OR THE WORK OF OTHER TENANTS BELOW. THE COST OF SUCH TESTS OR REPAIR OF ANY DAMAGE WILL BE BORNE BY THIS CONTRACTOR. ALL SLEEVES, OPENINGS, ETC, THROUGH FIRE RATED WALLS AND FLOORS SHALL BE. SEALED AFTER CONDUIT INSTALLATION TO RETAIN FIRE RATING. 8. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIR. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL, SUCH AS CHANNEL, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE SECURED TO THE BUILDING STRUCTURE, NOT TO PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHERE POSSIBLE. EXPOSED CONDUIT SHALL BE RUN IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES AND SEPARATED AT LEAST 3" FROM WATER LINES WHEREVER THEY RUN ALONG SIDE OR ACROSS SUCH LINES. 9. EVERY PART OF THE INSTALLATION SHALL BE TESTED, OPERATED AND LEFT IN PERFECT WORKING ORDER. TEST ALL WIRES AND CABLES INSTALLED UNDER THIS CONTRACT WITH A 1,000 VOLT MEGOHM METER. IF ANY READINGS ARE FOUND LOWER THAN REQUIRED BY GOOD PRACTICE OR APPLICABLE CODES, THE EQUIPMENT OR MATERIALS INVOLVED SHALL BE PROMPTLY REPLACED. SHOULD TESTING REVEAL ANY OTHER DEFECTS, PROMPTLY CORRECT ANY SUCH DEFECTS AND RERUN TESTS UN11L THE ENTIRE INSTALLATION IS SATISFACTORY IN ALL RESPECTS. 10. GUARANTEE: CONTRACTOR IS TO GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE PROJECT BY THE OWNER. IT IS UNDERSTOOD BY HIS ACCEPTANCE OF THE CONTRACT THAT THIS CONTRACTOR WILL MAKE GOOD ANY AND ALL WORK WHICH IN ANY WAY HAS BECOME DEFECTIVE AS TO THE QUALITY OF MATERIALS AND WORKMANSHIP FOR ANY CAUSE OTHER THAN ORDINARY WEAR AND TEAR. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND/OR INSTALLED BY HIM. i 11. THE CONTRACTOR, BEFORE FINAL ACCEPTANCE BY THE OWNER WILL BE GRANTED, SHALL CLEAN ALL LIGHTING FIXTURES, DEVICE PLATES, SERVICE FITTINGS AND OTHER ITEMS FURNISHED UNDER THIS CONTRACT. HE SHALL INSURE THAT ALL DIRECTORIES ARE IN PLACE WITH COMPLETED OR REVISED SCHEDULES AND ALL IDENTIFICATIONS AND MARKINGS OF EQUIPMENT, CABLES AND OTHER ITEMS ARE COMPLETED. 12. THIS CONTRACTOR SHALL COORDINATE SEQUENCE OF WORK WITH ALL OTHER TRADES. CONTRACTOR SHALL VERIFY VOLTAGE OF MECHANICAL EQUIPMENT AND FLUORESCENT FIXTURE BALLASTS, PRIOR TO COMMENCING ANY WORK. NO REMOVALS SHALL BE MADE WITHOUT OWNER'S APPROVAL. ALL EXISTING EQUIPMENT, MATERIALS, ETC.. THAT ARE NOT TO BE REUSED SHALL BE REMOVED COMPLETELY AND DISPOSED OF BY THIS CONTRACTOR. 13. THIS CONTRACTOR SHALL MAKE ARRANGEMENTS FOR TEMPORARY POWER AND SHALL PAY THE COST FOR THE UTILITY CONNECTION AND SHALL BE RESPONSIBLE FOR THE PROPER MAINTENANCE OF THE TEMPORARY WORK AND FOR THE REMOVAL OF SAME. CONTRACTOR SHALL PAY ALL UTILITY CHARGES IN CONNECTION WITH THE TEMPORARY POWER. CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL POWER EQUIPMENT USED ON THE PREMISES DURING CONSTRUCTION. 14. CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, SUPPLIES, EQUIPMENT AND FEES REQUIRED TO COMPLETELY INSTALL, TEST AND PLACE THE HEREIN SPECIFIED EQUIPMENT, COMPONENTS, CONTROLS, AND SYSTEMS IN SERVICE. SCOPE OF WORK: INSTALLATION OF ELECTRICAL SERVICE INCLUDING: WORK IN THE LANDLORD'S MAIN DISTRIBUTION EQUIPMENT SHALL BE AS INDICATED AND/OR REQUIRED. COMPLETE POWER AND LIGHTING DISTRIBUTION SYSTEMS INCLUDING ALL PANELS AND STEP DOWN TRANSFORMER. COMPLETE BRANCH CIRCUIT WIRING SYSTEM. PROVISIONS FOR OWNER SUPPLIED SECURITY SYSTEM. PROVISIONS FOR OWNER SUPPLIED DATA COMMUNICATIONS SYSTEM. PROVISIONS FOR OWNER SUPPLIED SOUND SYSTEM. PROVISIONS FOR OWNER SUPPLIED CLOSED CIRCUIT SURVEILLANCE SYSTEM. PROVISIONS FOR COMPLETE TELEPHONE SYSTEM. COMPLETE UTILITY MOTOR WIRING SYSTEMS, (EXCEPT AS NOTED) FOR ALL AIR CONDITIONING AND/OR HEATING EQUIPMENT, EXHAUST EQUIPMENT AND CONTROLS. ELECTRIC HEATING EQUIPMENT, CONTROLS AND INSTALLATION OF SAME. COMPLETE LIGHTING FIXTURE INSTALLATION FIXTURES ARE FURNISHED BY THE OWNER. COMPLETE TELEPHONE CONDUIT SYSTEM, INCLUDING SERVICE CONDUIT FROM POINT OF CONNECTION TO LANDLORD'S SYSTEM AND ALL TERMINAL DEVICES, BOXES, CONDUIT, PLATES, ETC. COMPLETE FIRE ALARM SYSTEM, INCLUDING INTERFACE WITH LANDLORD'S SYSTEM. TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR CONSTRUCTION. TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION. TESTING OF ALL ELECTRICAL EQUIPMENT WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF PROJECT CLOSE-OUT. 15. ELECTRICAL SERVICE: LANDLORD PROVIDES 208/120V, 3-PHASE, 4 WIRE SERVICE FOR THE LEASED SPACE. PROVIDE ELECTRICAL AS INDICATED ON THE DRAWING. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE ENTIRE INSTALLATION WITH THE LANDLORD. CONTRACTOR SHALL MAKE ARRANGEMENTS. WITH THE LANDLORD FOR INSTALLATION OF CHECK METER AT TENANT'S EXPENSE. 16. CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL TELEPHONE UTILITY FOR INSTALLATION OF SERVICE TO THE SPACE. LANDLORD HAS PROVIDED CONDUIT FROM LANDLORD'S TELEPHONE EQUIPMENT ROOM TO THE LEASED SPACE, FOR USE BY THIS CONTRACTOR. COORDINATE INSTALLATION OF TELEPHONE WORK AND INSTALL ALL CONDUIT FOR TELEPHONE SYSTEM WITHIN LEASED SPACE WITH OWNER'S TELEPHONE EQUIPMENT SUPPLIER. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM (UNLESS OTHERWISE NOTED) WITH SINGLE DEVICE AND COVER AND TELEPHONE PLATE. THIS CONTRACTOR PROVIDES ROUGH-IN'S ONLY. TELEPHONE EQUIPMENT, DEVICES AND ALL CABLING ARE PROVIDED BY OTHERS: CONTACT: MICHELLE BRODERICK PHONE: (206)882-6214 ELECTRICAL CONTRACTOR SHALL VERIFY ALL ROUGH -IN REQUIREMENTS PRIOR TO COMMENCING ANY WORK. ALL TELEPHONE ROUGH -INS SHALL BE INSPECTED BY TELECOMMUNICATIONS SUBCONTRACTOR PRIOR TO CLOSING OF WALLS AND CEILINGS. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO MAKE ARRANGEMENTS WITH THIS SUBCONTRACTOR FOR SUCH AN INSPECTION. 17. SOUND SYSTEM THIS CONTRACTOR SHALL PROVIDE ROUGH-IN'S ONLY (INCLUDING CONDUIT FOR WIRING AS INDICATED ON THE PLANS) FOR ALL SOUND SYSTEM COMPONENTS. ALL EQUIPMENT, DEVICES, ACCESSORIES, AND WIRING SHALL BE PROVIDED BY: PLAY NETWORK, INC. CONTACT: CORY NAHOOPII PH:(425) 629-1835 ELECTRICAL CONTRACTOR SHALL VERIFY ALL ROUGH -IN REQUIREMENTS PRIOR TO COMMENCING ANY WORK. ALL SOUND SYSTEM ROUGH -INS SHALL BE INSPECTED BY AUDIO SYSTEM SUBCONTRACTOR PRIOR TO CLOSING OF WALLS AND CEILINGS. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO MAKE ARRANGEMENTS WITH THIS SUBCONTRACTOR FOR SUCH AN INSPECTION. 18. DATA COMMUNICATION SYSTEM THIS CONTRACTOR SHALL PROVIDE ROUGH-IN'S ONLY (INCLUDING CONDUIT FOR CABLE AS INDICATED ON THE PLANS) FOR ALL DATA COMMUNICATIONS SYSTEM COMPONENTS. ALL EQUIPMENT, DEVICES, ACCESSORIES, AND CABLE SHALL BE PROVIDED BY: CONTACT: CELESTE BUSCONI PH: (508) 635-2006 ELECTRICAL CONTRACTOR SHALL VERIFY ALL ROUGH -IN REQUIREMENTS PRIOR TO COMMENCING ANY WORK. ALL DATA COMMUNICATIONS SYSTEM ROUGH-IN'S SHALL BE INSPECTED BY BY DATA COMMUNICATIONS SYSTEM SUBCONTRACTOR PRIOR TO CLOSING OF WALLS AND CEILINGS. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO MAKE ARRANGEMENTS WITH THIS SUBCONTRACTOR FOR SUCH AN INSPECTION. 19. SECURITY SYSTEM AND CLOSED CIRCUIT TELEVISION SYSTEM THIS CONTRACTOR SHALL PROVIDE ROUGH-IN'S ONLY (INCLUDING CONDUIT FOR CABLE AS INDICATED ON THE PLANS) FOR ALL SECURITY COMPONENTS. ALL EQUIPMENT, DEVICES, ACCESSORIES, CABLE SHALL BE PROVIDED BY: ADT CONTACT - MIKE LOTTES PH: (206) 391-5428 ELECTRICAL CONTRACTOR SHALL VERIFY ALL ROUGH -IN REQUIREMENTS PRIOR TO COMMENCING ANY WORK. ALL SECURITY SYSTEM ROUGH-IN'S SHALL BE INSPECTED BY SECURITY SYSTEM SUBCONTRACTOR PRIOR TO CLOSING OF WALLS AND CEILINGS. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO MAKE ARRANGEMENTS WITH THIS SUBCONTRACTOR FOR SUCH AN INSPECTION. 20. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. 20.1. THE WORD "PROVIDE" AS USED HEREIN MEANS TO FURNISH AND INSTALL COMPLETE. 20.2. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING COMPONENTS THEREOF, SHALL BE NEW AND SUCH AS APPEARS ON THE UNDERWRITER'S LABORATORY LIST OF APPROVED ITEMS AND SHALL MEET THE REQUIREMENTS OF RECOGNIZED STANDARDS. 20.3. EQUIPMENT SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES. 21. CONDUIT SHALL BE STANDARD STEEL, RIGID, IMC OR EMT (THIN WALL) ACCORDING TO CODE REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS, EXCEPT AS OTHERWISE APPROVED BY OWNER'S REPRESENTATIVE. EMT CONNECTIONS SHALL BE COMPRESSION TYPE. 21.1. MINIMUM SIZES OF CONDUIT SHALL BE 3/4", EXCEPT 1 /2" FOR SWITCH LEGS. EMT SHALL BE GALVANIZED OR ELECTRO-GALVANIZED. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE SUSPENDED CEILINGS OR CONCEALED IN INTERIOR PARTITIONS. EMT SHALL NOT BE CONCEALED IN POURED CONCRETE FLOOR OR WALLS. 21.2. USE HEAVY WALL CONDUIT OR IMC FOR UNDER SLAB INSTALLATIONS. IMC IS PERMITTED WITH SCREW CONNECTIONS. 21.3. FLEXIBLE METALLIC TUBING MAY BE USED IN LIEU OF EMT FOR CONCEALED BRANCH CIRCUIT WIRING ONLY, WHERE PERMITTED BY LOCAL AUTHORITIES. 22. ALL CONDUCTORS SHALL BE SOFT DRAWN, ANNEALED COPPER, WITH 600V INSULATION: 22.1. #10 AND SMALLER - SOLID WITH SINGLE BRAID. #8 AND LARGER - STRANDED WITH AT LEAST DOUBLE BRAID. MINIMUM WIRE SIZE SHALL BE #12, EXCEPT #14 MAY BE USED FOR CONTROL APPLICATIONS. 22.2. ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. 22.3. GENERAL WIRING SHALL HAVE THW, THHN OR THWN INSULATION. 22.4. ALUMINUM CONDUCTORS ARE NOT PERMITTED. 22.5. WIRE CONNECTORS SHALL BE EQUAL TO SCOTCHLOCK FOR #8 AND SMALLER, AND T & B "LOCK-TITE" FOR #6 AND LARGER. 22.6. WIRES SHALL BE COLOR CODED IN KEEPING WITH LANDLORD'S CONVENTION. 23. OUTLET BOXES AND COVERS SHALL BE ONE PIECE, GALVANIZED OR SHERARDIZED STEEL; 4" X 4-11 /16", KNOCKOUT TYPE WITH FIXTURE STUDS AS REQUIRED. JUNCTION BOXES, PULL BOXES AND COVERS SHALL BE GALVANIZED STEEL, CODE GAUGE AND SIZE. 24. WIRING DEVICES: WALL SWITCHES, SINGLE POLE, DOUBLE POLE, AND THREE WAY SHALL BE GENERAL DUTY, FLUSH, TOGGLE SWITCHES; SPECIFICATION GRADE, 20A 120/277V, WITH SCREW TERMINALS, MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. SEE DEVICES COLOR BELOW FOR MORE INFORMATION. GENERAL DUTY DUPLEX RECEPTACLES SHALL BE 2-POLE, 3-WIRE GROUNDING TYPE, SPECIFICATION GRADE, 20A, 125V, NEMA 5-20R UNLESS OTHERWISE INDICATED. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. SEE DEVICES COLOR BELOW FOR MORE INFORMATION. GROUND FAULT INTERRUPTER RECEPTACLE SHALL BE GENERAL DUTY, DUPLEX RECEPTACLES, GROUND FAULT CIRCUIT INTERRUPTER, FEED -THROUGH TYPE, CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES ON A SINGLE CIRCUIT, GROUNDING TYPE UL-RATED CLASS A, GROUP 1, 20A 120V, 60HZ; WITH SOLID-STATE GROUND -FAULT SENSING AND SIGNALING; WITH 5 MILLIAMPERES GROUND -FAULT TRIP LEVEL; IN NEMA 5-15R CONFIGURATION. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMOUR, OR LEVITON. DUPLEX ISOLATED GROUND TYPE RECEPTACLE SHALL BE 2-POLE, 4-WIRE, 15A STRAIGHT BLADE DEVICE WITH SEPARATE ISOLATED GROUND AND BUILDING GROUND CONNECTIONS, IN NEMA 5-20R CONFIGURATION, AS MANUFACTURED BY HUBBELL IG-5362. DEVICES COLOR: DEVICES INSTALLED ON GREY WALLS SHALL BE GREY. DEVICES INSTALLED ON BLACK WALLS SHALL BE BLACK. DEVICES INSTALLED ON KHAKI WALLS SHALL BE WHITE. ALL DEVICES INSTALLED AT THE BACK OF THE HOUSE SHALL BE WHITE. WIRING DEVICE ACCESSORIES INCLUDING ALL WALL PLATES SHALL BE PROVIDED AT EACH DEVICE. WALL PLATES SHALL BE SAME COLOR AS DEVICE AND MANUFACTURED AS A COMPANION TO THE DEVICE, EXCEPT IN COVER PLATES FOR DEVICES INSTALLED IN THE SALES AREA SHALL HAVE WHITE FINISH. MOUNTING HEIGHTS OF DEVICES SHALL BE TO THE FOLLOWING CENTERLINES (UNLESS NOTED OTHERWISE): TOGGLE SWITCHES 48" RECEPTACLES 15" WALL TELEPHONE OUTLETS 48" DISCONNECT SWITCHES 66" PANELBOARDS 60" 25. THIS CONTRACTOR SHALL PROVIDE, INSTALL AND CONNECT A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. A GOOD MECHANICAL AND ELECTRICAL CONNECTION SHALL BE MADE WITH APPROVED GROUNDING CONNECTORS. ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY WITH ALL LOCAL, STATE AND NEC CODES AND REGULATIONS. PANELS, CONDUIT SYSTEMS, MOTOR FRAMES, LIGHTING FIXTURES AND OTHER EQUIPMENT THAT ARE A PART OF THIS INSTALLATION SHALL BE SECURELY GROUNDED BOTH MECHANICALLY AND ELECTRICALLY IN ACCORDANCE WITH ALL CODES. MAIN GROUNDING SYSTEM SHALL BE SIZED TO CONFORM WITH SECTION 250, TABLE 250-94 OF THE NATIONAL ELECTRICAL CODE, PROVIDE CONDUIT TO PROTECT GROUND WIRE FROM DAMAGE TO AN AREA 6' ABOVE FLOOR. MAKE ALL JOINTS AND CONNECTIONS OF THE CONDUIT SYSTEM TIGHT TO CONTINUITY OF MECHANICAL AND ELECTRICAL GROUND THROUGHOUT SYSTEM. GROUND ALL 3 WIRE RECEPTACLES TO THE OUTLET BOXES. GROUND NEUTRAL FROM THE TRANSFORMER CONNECTED TO WATER LINE. PROVIDE NEUTRAL TO GROUND BOND AT TRANSFORMER SECONDARY. GROUND CONDUCTOR SHALL BE SUPPLIED IN ALL NONMETALLIC CONDUIT. A DEDICATED INSULATED GROUND CONDUCTOR SHALL BE INSTALLED FOR ELECTRONIC CASH REGISTERS, AND OTHER DEVICES INDICATED ON THE PLANS. 26. EXISTING TO BE RE -USED. REPLACE AS REQUIRED WITH THE FOLLOWING. LIGHTING PANEL BOARD SHALL BE 3-PHASE, 4-WIRE DISTRIBUTED PHASE TYPE WITH SOLID NEUTRAL, GROUND LUG, GROUND BUS AND NUMBER OF CIRCUIT BREAKERS AS SHOWN ON THE PANEL SCHEDULE. BUSBARS SHALL BE HARD DRAWN COPPER OR AL. CABINET SHALL BE CONSTRUCTED OF CODE. GAUGE STEEL WITH HINGED DOOR HAVING DIRECTORY CARD, NEATLY AND PROPERLY INSCRIBED AND SET IN FRAME WITH TRANSPARENT COVER. ELECTRICAL CONTRACTOR SHALL PERMANENTLY LABEL PANELBOARD BY MEANS OF LAMINATED BLOCK AND WHITE PHENONIC LABEL. ALL BREAKERS SHALL BE BOLTED TYPE, THERMAL MAGNETIC WITH ALL TWO OR THREE POLE BREAKERS HAVING COMMON TRIP. CIRCUIT BREAKERS SHALL DERATED FOR MINIMUM 10,000 AMP SYMMETRICAL SHORT CIRCUIT CURRENT AT 120/208V. CIRCUIT BREAKERS SERVING LIGHTING CIRCUITS SHALL BE RATED FOR SWITCH SERVICE. PANELBOARDS AND BREAKERS SHALL BE AS MANUFACTURED BY SQUARE-D EQUAL. PROVIDE "LOCK -ON" DEVICE AT BREAKERS SERVING NIGHT -LIGHT / EMERGENCY CIRCUIT, CASH REGISTER, AND TIME SWITCH CIRCUIT. PANEL SHALL BE CIRCUITED SO THAT THE LOAD IS DISTRIBUTED EVENLY ACROSS ALL THREE PHASES.; 27. PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NON -FUSED, AS CALLED FOR ON DRAWING AND AS REQUIRED BY CODE. SWITCHES SHALL BE HEAVY DUTY, LOAD AND HORSEPOWER RATED AS MANUFACTURED BY SQUARE-D, GENERAL ELECTRIC, OR EQUAL. SWITCH ENCLOSURE TO BE SUITABLE FOR APPLICATION. FURNISH AND INSTALL DUAL ELEMENT CURRENT LIMITING FUSES, OF TYPE AND AMPACITY DESIGNED TO PROTECT SYSTEM AGAINST AVAILABLE SHORT CIRCUIT FAULT CURRENT. 28. PROVIDE DRY -TYPE TRANSFORMER WHICH SHALL BE ENCLOSED, VENTILATED TYPE WITH KVA AND VOLTAGE RATINGS AS CALLED, FOR ON THE DRAWING AS MANUFACTURED BY SQUARE-D. TRANSFORMER SHALL HAVE A MINIMUM OF 150 DEGREE, CLASS H INSULATION AND A MINIMUM OF (4) 2-1 /2% TAPS BELOW ANAD (2)2-1/2% TAPS ABOVE RATED PRIMARY VOLTAGE. SOUND LEVEL SHALL BE LOW AND INSTALLATION SHALL INCLUDE VIBRATION DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY CONNECTIONS TO MINIMIZE SOUND TRANSMISSION. MOUNT TRANSFORMER ON VIBRATION ISOLATORS. 29. HEATING AND COOLING MOTORS AND CONTROLS ALL LINE AND LOW VOLTAGE POWER AND CONTROL WIRING INCLUDING TEMPERATURE CONTROL WIRING, CONNECTION TO DAMPERS, INSTALLATION OF THERMOSTATS, INTERLOCKING, ETC. EXCEPT AS SPECIFICALLY NOTED AS BEING BY MECHANICAL CONTRACTOR, SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CONTROLS, EXCEPT AS NOTED, WILL BE SUPPLIED BY THE MECHANICAL CONTRACTOR TO THIS CONTRACTOR WHO SHALL DO ALL INSTALLATION AND AND WIRING. ELECTRICAL CONTRACTOR SHALL CONNECT ALL MOTORS, SUPPLIED BY THE MECHANICAL CONTRACTOR, WHICH DO NOT COME FACTORY WIRED IN THE EQUIPMENT. ELECTRICAL CONTRACTOR SHALL PERMANENTLY LABEL ALL DISCONNECT SWITCHES, CONTACTORS, CONTROLS AND BOXES IN THE SYSTEMS. IDENTIFY EACH AS TO USE, ON THE FACE OF CABINETS OR COVERS BY MEANS OF A LAMINATED BLACK AND WHITE PHENOLIC LABEL. 30. LIGHTING FIXTURES: THE CONTRACTOR SHALL PROVIDE A NEW LIGHTING FIXTURE OF THE TYPE SPECIFIED FOR EACH LIGHTING OUTLET SHOWN WITH COMPLETE LAMPS OR TUBES. ALL FIXTURES SHALL BE HUNG AND MOUNTED IN PLACE, PROPERLY WIRED, TESTED AND LEFT READY FOR OPERATION. THE OWNER SELECTS AND PROVIDES THE LIGHTING FIXTURES, COMPLETE WITH ACCESSORIES AND LAMPS. SEE LIGHTING FIXTURE SCHEDULE ON PLANS. THIS CONTRACTOR PROVIDES INSTALLATION ONLY. FIXTURES, LAMPS AND ACCESSORIES ARE PROVIDED BY: WESTERN EXTRALITE CONTACT. KATHY HENRY PH: (888) 939-4399 FIXTURES PROVIDED BY THE OWNER SHALL BE SHIPPED TO THE SITE FOR INSTALLATION BY THE CONTRACTOR. THE CONTRACTOR SHALL SURVEY THE SHIPMENT TO VERIFY FIXTURE QUANTITIES AND DAMAGES. IN THE EVENT THAT SHIPMENT IS INCOMPLETE OR DAMAGED, CONTRACTOR SHALL INFORM THE OWNER. AFTER THE SHIPMENT IS VERIFIED AND ACCEPTED, CONTRACTOR SHALL MOVE FIXTURE TO AN AREA OF SAFETY FOR STORAGE UNTIL THEY MAY BE INSTALLED. HE ASSUMES RESPONSIBILITY FOR THE FIXTURES UNTIL THE PROJECT IS TURNED OVER TO THE OWNER. 31. LIGHTING CONTROLS (EXISTING TO BE REUSED, MODIFY IN FIELD AS REQUIRED). CIRCUITS FOR STORE FRONT LIGHTING SHALL BE CONTROLLED BY A PROGRAMMABLE TIME SWITCH. SWITCH SHALL BE EQUAL TO TORK SERIES 1100, SYNCHRONOUS MOTOR -DRIVEN 40-AMPERE, 24 HOUR, 7 DAYS -A HOUR, 7-DAYS-A-WEEK, WITH SKIP -A -DAY FEATURE. UNIT SHALL BE FURNISHED WITH NEMA 1 ENCLOSURE. ALL OTHER CIRCUITS OF SALES AREA LIGHTING SHALL BE CONTROLLED BY MUL11POLE MECHANICALLY HELD LIGHTING CONTACTORS. PROVIDE SEPARATE CONTACTORS FOR FLUORESCENT LIGHTING CIRCUITS AND TRACK LIGHTING CIRCUITS. CONTACTORS ARE, IN TURN, CONTROLLED BY MOMENTARY CONTACT SWITCHES. MULTIPOLE LIGHTING CONTACTORS SHALL BE MAGNETIC LIGHTING CONTACTOR, MECHANICALLY HELD AND ELECTRICALLY OPERATED WITH ENCAPSULATED COILS. STANDARD COIL CLEARING CONTACTS ARE TO BE PROVIDED SO THAT THE CONTACTOR COILS SHALL BE ENERGIZED ONLY DURING THE INSTANCE OF OPERATION. COIL VOLTAGE: 120V AC NUMBER OF POLES SHALL BE AS SCHEDULED. CONTACT RATING: 20 AMPERES FOR ALL TYPES OF BALLAST AND TUNGSTEN LIGHTING, RESISTIVE HEATING, AND MOTOR LOADS. CONTACT: TOTALLY ENCLOSED, DOUBLE -BREAK SILVER -CADMIUM -OXIDE POWER CONTACTS. CONTACT INSPECTION AND REPLACEMENT SHALL BE POSSIBLE WITHOUT DISTURBING LINE OR LOAD WIRING. ALL CONTACTS SHALL HAVE CLEARLY VISIBLE N.O. AND N.C. CONTACT STATUS INDICATORS. LIGHTING CONTACTORS SHALL BE EQUAL TO SQUARE D SERIES 8903 MODEL LGX 1200-V02-Y1002. CONTACTOR SHALL BE CONTROLLED BY PASS AND SEYMORE #1251 MOMENTARY CONTACT SWITCH. 32. PAINTING OF ELECTRICAL CONDUITS, ETC.. IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. 33. DOORBUZZER SYSTEM (EXISTING TO BE REUSED, MODIFY IN FIELD AS REQUIRED). THE PUSHBUTTON SHALL BE MOUNTED IN THE WALL NEXT TO THE DOOR AT 4' -6" A.F.F. THE BUZZER SHALL BE MOUNTED IN THE STOCK ROOM AT 10'-0" (OR JUST BELOW ANY STOCK ROOM CEILING) IN A POSITION LOCATED CLOSE TO THE ENTRY TO THE SALES AREA. BUZZER: EDWARDS - 725 OR EQUAL CHIME: EDWARDS - 55 - 6G5 - OR EQUAL PUSHBUTTON: EDWARDS - 632 - OR EQUAL TRANSFORMER: 1OV, 5VA SECONDARY EDWARDS - 590 OR EQUAL WIRE: #20 AWG STRANDED BELL WIRE 34. FINALLY. IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. THE LOCATION OF RECEPTACLES AND FIXTURES SHOWN ON THE DRAWING IS APPROXIMATE AND THE OWNER SHALL HAVE THE RIGHT TO RELOCATE ANY RECEPTACLES OR FIXTURES BEFORE, THEY ARE INSTALLED WITHOUT ANY ADDITIONAL COST. I 35. CABLE TYPES AC AND NM ARE NOT ALLOWED. IF USED, FLEXIBLE TYPE MC CABLE SHALL HAVE A BLUE STRIP. 36. PROVIDE FIRE ALARM SHUTDOWN REQUIREMENT FOR INTERCONNECTION TO TENANT'S AIR HANDLING UNITS. 37. TENANT SHALL CONNECT TO MALL FIRE ALARM SYSTEM FOR COMPLETE MONITORING. ELECTRICAL SYMBOL LEGEND POWER SYMBOL DESCRIPTION qp DUPLEX RECEPTACLE MOUNTED AT 15"AFF UNLESS NOTED OTHERWISE QUAD PLEX RECEPTACLE MOUNTED AT 15"AFF UNLESS NOTED OTHERWISE �DG DUPLEX DEDICATED GROUND TYPE RECEPTACLE MOUNTED AT 15"AFF UNLESS NOTED OTHERWISE �,.DG �` QUAD PLEX ISOLATED GROUND TYPE RECEPTACLE MOUNTED AT 15"AFF UNLESS NOTED OTHERWISE �GFi DUPLEX GROUND FAULT INTERRUPTING TYPE RECEPTACLE JUNCTION BOX MOTOR CONNECTION DISCONNECT SWITCH ® 480/277 VOLT, SURFACE MOUNT SINGLE SECTION PANELBOARD 208/120 VOLT, SURFACE MOUNT SINGLE SECTION PANELBOARD COMMUNICATIONS ROUGH -IN FOR TELEPHONE VOICE LINE MOUNTED AT 15"AFF UNLESS NOTED OTHERWISE sz ROUGH -IN FOR TELEPHONE VOICE / DATACOM MOUNTED AT 15"AFF UNLESS NOTED OTHERWISE EMPTY CONDUIT FOR TELEPHONE CABLES TO BE INSTALLED BY COMMUNICATIONS SUB CONTRACTOR EMPTY CONDUIT FOR DATA CABLES TO BE INSTALLED BY DATA COM SUB CONTRACTOR DOOR BUZZER SIGNALING Q DOOR BUZZER PUSHBUTTON - LOCATED AT REAR DOOR ri REMOTE DOOR BUZZER DOOR BUZZER AND SIGNALING TRANSFORMER SECURITY SYSTEM ❑KP S KEY PAD LOCATION - PROVIDE ROUGH -IN ONLY [EMD INFRARED MOTION DETECTOR LOCATION - PROVIDE ROUGH -IN ONLY sB SHATTER BOX - PROVIDE ROUGH -IN ONLY ALARM HORN ON CEILING - PROVIDE ROUGH -IN ONLY ADC DOOR CONTACT SWITCH - PROVIDE ROUGH -IN ONLY SOUND SYSTEM CEILING SPEAKER LOCATION - PROVIDE ROUGH -IN ONLY Q WALL SPEAKER LOCATION - PROVIDE ROUGH -IN ONLY Q VOLUME CONTROL DEVICE (WALL MOUNTED) - PROVIDE ROUGH -IN ONLY FIRE ALARM SYSTEM FA�CP FIRE ALARM CONTROL PANEL OH HEAT DETECTOR F FIRE ALARM HORN ODs DUCT MOUNTED SMOKE DETECTOR P CEILING MOUNTED SMOKE DETECTOR F HORN STROBE -NUMBER INDICATES CANDELLA OF STROBE F STROBE - NUMBER INDICATES CANDELLA OF STROBE Q PULL STATION LIGHTING CONTROL I WALL MOUNTED TOGGLE SWITCH 3 I 3-WAY WALL MOUNTED TOGGLE SWITCH PROGRAMMABLE TIME CLOCK (TO CONTROL STOREFRONT LIGHTING CIRCUITS) Q CONTACTOR (MULTI -POLE) City ®f-TukW a ' BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN T9 2015 PERMIT CENTER HE Project No: R 1 5- 2 1 24.01 3 ARcH[TEcr 0 ul z m M W O m (D (D ca c3� �-�/ =19 W LL v W OOW m �O JZ E i �Z58 Darn = CU n z 2ul� = W =Eto to �.FETTI;,, o. iWAS s��! 44050 O' ISTE�� �0' SIONALG1 EXPIRESJZ�j/ZO�� LL Review Set Issued: 05/OG/201 5 Permit Set Issued: 05/2G/201 5 51d Set Issued: 05/2G/201 5 Construction Set Issued: Revisions No.: Date: drawn by: CTC reviewed by: KLS/PJF scale: AS NOTED Sheet Title ELECTRICAL SPECIFICA'nONS AND SYMBOL LEGEND Sheet No.