HomeMy WebLinkAboutPermit EL15-0528 - COMCAST - SERVICE, TRANSFORMER, PANEL, HVAC CIRCUITSCOMCAST
393 STRANDER BLVD
EL15-0528
City of Tukwila
Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.itov
ELECTRICAL OTC PERMIT
Parcel No: 2623049064
Permit Number: EL15-0528
Address: 393 STRANDER BLVD
Issue Date: 7/7/2015
Permit Expires On: 1/3/2016
Project Name: COMCAST
Owner:
Name: REGENCY CENTERS LP
Address: PO BOX 790830 C/O PROPERTY TAX
DEPT, SAN ANTONIO, WA, 78279
Contact Person:
Name: ROBBIE BURRILL
Phone: (253) 737-4367
Address: 206 FRONTAGE RD N SUITE A2 ,
PACIFIC, WA, 98047
Contractor:
Name: MASTERCRAFT ELECTRIC INC
Phone: (253) 737-4367
Address: 206 FRONTAGE RD N STE A2, PACIFIC,
WA, 98047-1051
License No: MASTEE112768
Expiration Date:
Lender:
Name:
Address:
DESCRIPTION OF WORK:
NEW 100AMP 480V SERVICE TO NEW RETAIL SPACE. METER, 100 AMP 480V FUSED DISCONNECT, 75KVA
120/208V TRANSFORMER, REUSE EXISTING 200AMP 120/208V PANEL, (3) HVAC ROOFTOP UNITS 208V 30AMP
CIRCUITS, RE -CONFIGURE EXISTING LIGHTING. CORE/SHELL WORK FOR FUTURE TENANT
Valuation of single family: $0.00
Fees Collected: $303.98
Valuation of mf/comm: $11,000.00
Type of Work: TENANT IMP
Electrical Service Provided by: PUGET SOUND ENERGY
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2012
National Electrical Code:
2014
International Residential Code Edition:
2012
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2012
WAC 296-46B:
2014
Uniform Plumbing Code Edition:
2012
WA State Energy Code:
2012
International Fuel Gas Code:
2012
Permit Center Authorized Sign
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to th conditions attached to this permit.
Signature: � Date: 7
Print Name: i� r)i1 l�w✓v i I i
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: 'ELECTRICAL PERMIT CONDITIONS'
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical
Inspector at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical
Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations,
Chapter 296-46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts
of the building, such equipment shall not be concealed until it has been inspected and approved by the
Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any
violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related
documentation that presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work
permits. Where approved plans have been issued, revisions to the plans and additional review may be
required.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2100
ELECTRICAL FINAL
7003
ROUGH -IN ELECTRICAL
7002
SERVICE
7001
UNDERGROUND/SLAB
CITY OF TUKWILA
Community Development Department
Permit Center
• 6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
hfp://www.Tukwi]aWA.gov
SITE LOCATION
Electrical Permit No. �N V
Project No.
Date Application Accepted: I
Date Application Expires: Vat I I 11
(For office use only
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the snail or by fax.
"Please Print"
King Co Assessor's Tax No.:
Site Address: 393 Strander Blvd ukwila, WA _ Suite Number: B Floor: 1
Tenant Name: Future TBD /�� New Tenant: m .....Yes ❑ ..No
PROPERTY OWNER
Name: Regency Centers
Address: 5335 Meadows Rd, Suite 295
City: Lake Oswego State: OR Zip: 97035
CONTACT PERSON — person receiving all project
communication
Name: Robbie Burrill
Address: 206 Frontage Rd N Suite A2
City: Pacific State: wa Zip: 98047
Phone: (253) 737-4367 Fax: (253) 737-4812
Email: robbieb@mastercraftinc.com
Valuation of Project (contractor's bid price): $ 11,000
Scope of Work (please provide detailed information):
ELECTRICAL CONTRACTOR INFORMATION
Company Name: Mastercraft Electric
Address: 206 Frontage Rd N Suite A2
City: pacific State: WA Zip: 98047
Phone: (253) 737-4367 Fax: (253) 737-4812
Contr Reg No.: MASTEEI1127138 Exp Date: 12/05/2016
Tukwila Business License No.: BUS-0993713
New 100amp 480v service to new retail space. Meter, 100amp 480v fused disconnect, 75kva 120/208v transformer, Reuse existing
200amp 120/208v panel, (3) HVAC rooftop units 208v 30amp circuits, Re -configure existing lighting. Core/shell work for future
tenant.
Will service be altered? ❑ Yes ❑ No
Type of Use: Retail Future use
Type of work:
❑ New ❑ Addition ❑ Service Change
❑ Low Voltage ❑ Generator ❑ Fire Alarm
Property Served by:
m Puget Sound Energy ❑ Seattle City Light
HAApplicationsTorms-Applications On Line\2011 Applications0ectrical Permit Application Revised 9-9-I I.doex
Revised. August 2011
bh
Adding more than 50 amps? )� Yes ❑ No
❑ Remodel m Tenant Improvement
❑ Telecommunication ❑ Temporary Service
Page I of 2
I'll Xy111D000MI
NEW RESIDENTIAL SERVICE
❑ New single family dwellings...................................$152.85
(including an attached garage)
❑ Garages, pools, spas and outbuildings ........................ $81.90 ea
❑ Low voltage systems
(alarm, furnace thermostat)................................$59.85 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑
Service change or alteration ......................................
$81.90
(no added/altered circuits)
❑
Service change with added/altered circuits .................
$81.90
number of added circuits .......................
$11.55 ea
❑
Circuits added/altered without service change ...........
$54.60
(up to 5 circuits)
❑
Circuits added/altered without service change ...........
$54.60
(6 or more circuits) ...............................................
$7.65 ea
❑
Meter/mast repair .......................................................
$68.25
❑
Low voltage systems .................................................
$59.85
(alarm, furnace thermostat)
PERMIT APPLICATION NOTES -
MULTI -FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑
Temporary service (residential) .................................
$63.00
❑
Temporary service (generator) ...................................
$78.75
❑
Manufactured/mobile home service ...........................
$84.00
(excluding garage or outbuilding)
❑
Carnivals....................................................................$78.75
Number of concessions .........................
$10.50 ea
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature: Date: ` / -
Print Name: Robbie Burrill
Mailing Address: 206 Frontage Rd N, Suite A2
Day Telephone: (253) 737-4367
Pacific Wa 98047
City State Zip
H:\Applications\Forms-Applications On Line\2011 Applications\Electrical Permit Application Revised 8-9-1 I.docx
Revised. August 2011
bh
Page 2 of 2
DESCRIPTIONS
PermitTRAK
PAID
$303.98
EL15-0528 Address: 393 STRANDER BLVD
Apn: 2623049064
$303.98
ELECTRICAL
$289.50
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$289.50
TECHNOLOGY FEE
$14.48
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: 14
R000.322.900.04.00 0.00
$14.48
$303.98
Date Paid: Thursday, June 11, 2015
Paid By: MASTERCRAFT ELECTRIC
Pay Method: CREDIT CARD 01806G
Printed: Thursday, June 11, 2015 8:37 AM 1 of 1 rp SYSTEMS
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO, PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:60`4 tvs
Type of Inspection:
Address: c
73
Date Called:
Special Instructions:
Date Wanted: a.m
Lt 3
Requester:
Phone No:
U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION N0. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
Type of Inspection:
Address:
'gjr
Date Called:
Special Instru tions:
Date Wanted:
7/0
a.m.
z m.
Requester:
Phone No: ���
�py
Approved per applicable codes. [" Corrections required prior to approval.
COMMENTS:
I-) C,0n0/It7 f / N C-1) t �"
IInspector: `/���( � I IDate: n)?10' /C<— I
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670
Project:
C
Type of Inspection:
SpV-V 1 C�Q,
Address: � �
Date Called: �
Y
Special Instructions:
Date Wanted:
Requester:
Phone N : y, _
a,�.7
V
u paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
ipt No.: I Date:
INSPECTION RECORD
Retain a copy with permit (�
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
Type of Inspection: Ko L/4 tpj
Address:
G
Date Called:
Special Instructions:
Date Wanted:
p.
Requester:
Phone No:
9 Approved per applicable codes. EI Corrections required prior to approval.
COMMENTS:
L-C�b
/Lt A b
nspector:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
r INSPECTION RECORD ,I L _ — L
Retain a copy with permit (
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project: -- -
Type of Inspection: l + r
V CT
Address: 375 1
Date Called:
Special Instructions:
Date Wanted:
`.6 p.m.
Requester:
Phone No: �'� V 5-1
❑ Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
M.M&MMAM,MR.A"M R, I.wi�
4
IInspector: 'C 'If elhfr`W62, IDate: 01II,G, It 4
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
ELECTRICAL TR70707 M
Existing
480v bus
izutter
1 1.5" C, 4#1 Alum,
#8CU grnd
t
1.5" C, 4#1 Alum,
#8CU grnd
JONELINE DIAGRAM
New 100a 480v
Meter
New 100a 480v
fused
disconnect with
90 amp fuses
1.5" C, 4#1 Alum,
#8CU grnd
REVIEWED FUH
COMPLIANCE WITH
NFPA 70 - NEC
JUN 2 4 2015
City of Tukwila
BUILDING DIVISION
TENANT SPACE 393E
REVISIONS
No changes shad ho made to thp scope
of work ivithouq prior approval of
S Ens ,l',61a Building Division_
.. ,'ss'.."iC trill rc quire a nett, plan submittal
an may i;
New
Transformer
75kva
120/208v
3ph
I T I
200amp
Disconnect
with
200amp
fuses
Reuse
existing MLO
200a Pnl
120/208v
3ph
2.5" C
4#250 Alum,
#6CU grnd
2.5" C
4#250 Alum,
#6CU grnd
Permit I io. EL f s' - D S,Lg
n rovie`;.y apprm al is subject to errors and orn'i mv.nsCITY OF T U K W I L A
,1A-'-ip-loval of C nstr coon documents does not authorize JUN 1 f 2015
Iliho Violation of any adopted code or ordinance. Receipt
f"
of pxpprovad field Copy and ditions is acknowledged:PERMIT CENTER
Date: -7 �7//S
City of Tukwila
BUILDING DIVISION
� u5-o52�
A
4
G STRANDER BLVD. J
SIDEWALK
I I
PLANTING STRIP
SIDEWALK - - -
1 I
RAISED SEATING
PLI TFORM TO BE
SIDEWALK
DEMO EXISTING
FLOORING
THROUGHOUT
(EXCEPT
RESTRooMs)
STRANDER BLVD, J Y •7
SIDEWALK
1WM AIIII
I I I
PLANTING STRIP
SIDEWALK IIIIIIM L
\/
I
EXISTIN
EXIT #
EXISTING COLUMNS REMOVE
COLUMN WRAP WHERE
OCCURS_ - - - -
I
PQo 1
np I
I
rltl
I u
I
EXIS ING
SEAJ11�II TO BE
DEMOLISHED, TYP. SIDEWALK
A"�14 —
REMOVE EXISTING 1
WALL TILE. PATCH _
REPAIR GWB. _ -_"V e �_
- - - PREPARE FOR PAINT F-t - - - -
�- -
a Sulle 393
o 8,015 S.F. m, MEN
OPEN CEILING 1 0
m 15'-7" AFF
BOT. OF JOIST
DEMO EXISTING WALLS
I ` .
COUNTERS, DOORS,
� � . I •
. -_____________ SOFFITS ETC
n \ yry��-------------
-----------11.------T
,'Irl
DEMO EXISTING (OFFICE
WALK-IN COOLER u n y
i
I I
i I
I ii I1 � WY
o AL
r EXISTING DEMISING WALL.
REPLACE DAMAGED GWB AND o SPRINKLER
SOUND BATT INSULATION, ROOM
FRAMING AS REQUIRED
(NO DEMO ORK)
_-_-_-
ADJACENT TENANT
(NO WORK)
I I I
DEMO PLAN
1/81, = I,_p„
DEMO NOTES:
• REMOVE ALL FLOORING DOWN TO EXPOSED CONCRETE. REMOVE RESIDUE, MORTAR, ETC.
FILL CRACKS IN SLAB......
• CEILINGS: REMOVE ALL T-BAR, ACT, & GWB. CEILING TO REMAIN OPEN TO STRUCTURE.
• LIGHTING: REMOVE ALL LIGHT FIXTURES EXCEPT AS REQUIRED TO MINIMAL ILLUMINATE
SPACE PER CODE. EXIT SIGNS TO REMAIN.
• SPRINKLER SYSTEM TO REMAIN UNTOUCHED: PROTECT ALL HEADS FROM DAMAGE DURING
DEMOLITION.
• BATHROOMS: REMOVE EXISTING TILE / PATCH AND REPAIR GWB AS NEEDED AND
PREPARE FOR PAINT.
• REMOVE ALL WAINSCOTING, FRP, WALL PAPER, WALL TILE, ETC, PATCH AND REPAIR GWB
AS NEEDED. PREPARE GWB FOR PAINT.
• ALL GWB TO BE PATCHED AND REPAIRED AS REQUIRED - TAPE, MUD AND SAND. GWB
TO BE READY FOR PAINT.
• CUT BACK AND CAP ALL PLUMBING / GAS.
• DEMO EXISTING DUCTS.
• DEMO EXISTING EXTERIOR SIGNS. DEMOLISH ANY EXISTING BUILT-IN CABINETS, FOOD
SERVING STATIONS, SEATING BOOTHS, COLUMN WRAPS, ETC.
• REMOVE ALL EXISTING FF & E / RESTAURANT EQUIPMENT
i
0
)200amp
LEGEND:
WALL TO BE DEMOLISHED
EXISTING WALL TO REMAIN
0 NEW WALL
DOOR TO BE DEMOLISHED
I DOOR TO REMAIN
-
(
EXISTING COLUMNS REMOVE
COLUMN WRAP WHERE
EXISTING SUITE 993e
i EDGE OF WALL ABOVE
EXIT #1 3,777 OLA
RIDGE OF SKYLIGHT ABOVE
Open Ceiling
15'-7" AFF
_
BOT. OF JOIST
EDGE OF SKYLIGHT ABOVE
tlIn
3" GREASE LINE
STUB TO CONNECT 3" IS STU
z
;
TO EXISTING GREASE (UNDER
a
s
INTERCEPTOR (UNDER (SEPARATE
a
a
3
SEPARATE PERMIT) PER
NEW DEMISING
NEW
QENM ItJG
NEW DEMISING
m
SIDEWALK WALL
WALL(
WALL SIDEWALK
0
2
2
3.
I
NEW ELEC.
PANELS
(UNDER
Y
5
E
i SEPARATE 5
PERMIT) A},1
w
E
r_
O
�p�
,
7-1/2" WATER L
E
STUB WITH SHUTOFF
VALVE SUSPEND
-
FROM
L
,.N�..
(V-t`
TJL'S ABOVE
e
r -
UNDER SEPARAT€
PERMIT _ _ - -
CITY
_
F 1
a
Y.
(�
3
N
2" GAS LINE
STUB WITH SHUT}OFF
VALVE SUSPENDE
FROM
`J�
N 1 -1 2015
SUITE 393E f
TJL'S ABOVE (UNDER
i°
MENS ,
_
0
JTINC �,238 DLA '
SEPARATE PERMI
)
p
#1
P
R
IT CENTER
BOT. OF JOIST
XISTING LADDER
FOR STORAGE
ACCESS
OFFICE
PA�QH REPAIR
J Z
J
0
EXISTING SERVICE
SINK TO REMAIN
WB AS
a
EQUIRED
�j
m
}
EXI
IT A
New T-ail Sf.rme:',
Dis
Z
((>
CONTROLS
LIGHTING /
connect, and
existing Panel
W Z W (�
T' PnT
may Q Q
S
*
I
FIRE
i Z 3
y
STORA
SPRINKLER
ROOM
W a
W
cc
Cz}
ADJACENT TENANT
(NO WORK)
L�
I
I
1
To main elects sal
'room
y LU F
I
, In adacert
FLOOR
PLAN
�502
REVIEW�D FU
1/8" - v-0.,
7
COMPLIANCE WITS
4BRUARY 4, 2015
NFPA 70 - NFt.
FLOOR PLAN
JUN 2 4 2015
I
^ %�
�_ 0 C)
A2.1
��'g�Li
I
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: EL15-0528
PROJECT NAME: COMCAST
SITE ADDRESS: 393 STRANDER BLVD
DATE: 06/17/15
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
�-$ )b4�j C,
Building Division Fire Prevention ❑ Planning Division ❑
Public Works ❑ Structural ❑ Permit Coordinator ❑
PRELIMINARY REVIEW: DATE: 06/18/15
Not Applicable ❑ Structural Review Required ❑
(no approval/review required)
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 07/16/15
Approved ❑ Approved with Conditions
Corrections Required ❑ Denied
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
MASTERCRAFT ELECTRIC INC
Home Inicio en Espauiol Contact
Page I of 3
Search L&I'�
Safety
Washington State Department of
Labor & Industries
MASTERCRAFT ELECTRIC INC
Owner or tradesperson
Principals
WALIOR, CHAD P, PRESIDENT
WALIOR, CHAD P, AGENT
DARLING, GARY, PRESIDENT
(End:04/01/2007)
Doing business as
MASTERCRAFT ELECTRIC INC
WA UBI No.
601 059 585
License
A-L 1:ndex Help My Secure L&I
Claims & Insurance Workplace Rights Trades & Licensing
206 FRONTAGE RD N STE A2
PACIFIC, WA98047-1051
253-737-4367
KING County
Business type
Corporation
Governing persons
CHAD
WALIOR
JAMES D UNGER;
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Electrical Contractor Active.
................ _............................................
Meets current requirements.
License specialties
GENERAL
License no.
MASTEEI127138
Effective — expiration
01/28/1988— 02/01/2016
Designated administrator
Active.
Walior, Chad
Meets current requirements.
License type
License no.
Electrical Administrator
WALIOC`896JD
Bond
...............
CBIC
$4,000.00
Bond account no.
SH4972
Received by L&I
Effective date
09/04/2007
08/29/2007
Expiration date
Until Canceled
Savings
No savings accounts during the previous 6 year period.
License Violations
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601059585&LIC=MASTEEI I27B8&SAW= 7/7/2015