Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL15-0690 - CENTURYLINK - WIRE FEEDER AND PANEL BOARD
CENTURYLINK 610IS180 TH ST 101 EL15-0690 City of Tukwila • Department of Community Development + 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 3523049120 Permit Number: EL15-0690 Address: 6101 S 180TH ST 101 Issue Date: 8/25/2015 Permit Expires On: 2/21/2016 Project Name: CENTURYLINK Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028, TUKWILA, WA, 98138 Contact Person: Name: JEFF JOHNSON Phone: (206) 276-6348 Address: 16134 TUKWILLA RD NE, POULSBO, WA, 98370 Contractor: Name: MCCOY ELECTRIC COMPANY INC Phone: (503) 234-7521 Address: 2014 SE 9TH AVE, PORTLAND, OR, 97214 License No: MCCOYEC381JT Expiration Date: 7/30/2017 Lender: Name: Address: DESCRIPTION OF WORK: INSTALL 400 AMP 480 VOLT 2 PHASE 3 WIRE FEEDER AND PANELBOARD FOR FUTURE RECTIFIERS Valuation of single family: $0.00 Fees Collected: $1,250.74 Valuation of mf/comm: $48,030.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit a agree to the conditions attached to this permit. Signature: Date: Print Name: S This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB f CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hgp://www.TukwilaWA.gov Electrical Permit No. 'LL- [ y — a �q o Project No. ) Date Application Accepted: Date Application Expires: 1' or office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION // Site Address: -TA 5e-t b� ` King Co Assessor's Tax No.: Suite Number: 1 b J Floor: Tenant Name: C'�-ter" I �lN New Tenant: ❑ .....Yes No PROPERTY OWNER Name: Cr -�..! tV Address: 6 i s. b O City: To lGt l� U State: W� ZipYt cJ r90 CONTACT PERSON - person receiving all project communication Name: e/ Ja MLA Address: �t0 %3 I UK M 114 WA A CityTlJ�-L&" State: V./l _ Zip 31-0 Phone:-z,t(p,n6 b3 G QFax: Email: k4 Ake CO C ELECTRICAL CONTRACTOR INFORMATION Company Name: W- Co S— (f r--m, C Co' I � . Address: ZO + li S1e:�- City: P© /Z+L State: Zip Ca}Zl Phone: '?,p(o_� G34g Fax: 5,,,.3>- 23 _ 9 L(} � ContrReg No.:jyC3gi Ex Date:. Tukwila Business License No.; Valuation of Project (contractor's bid price): $ T 8, 0 3 0 c 14 d , Scope of Work (please provide detailed information): 'I NS'IQ� 4 LIG o ALR q $ QVVI-,- '' `A.,�p�� 31,4\ ? 5 n� Will service be altered? ❑ Yes I] No Adding more than 50 amps? 10 Yes ❑ No Type of Use: Tvoe of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel [< Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Properiy Served bv: .jjr Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms-Applications On Line\2014 Applications\Glecirical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page t of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENT[AL.REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: ��c �>n& Ova Day Telephone: Mailing Address: I O' �I �U L ti �� �� "FtAs a ,04- 9 City State Zip H:Wpplications\Fom Applications On Line\2014ApplicationsTlectrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,010.21 EL15-0690 Address: 6101 S 180TH ST 101 Apn: 3523049120 $1,010.21 ELECTRICAL $962.10 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.0077 0.00 $962.10 TECHNOLOGY FEE $48.11 TECHNOLOGY FEE • '6111 R000.322.900.04.00 0.00 $48.11 $1,010.21 Date Paid: Tuesday, August 25, 2015 Paid By: JEFF JOHNSON Pay Method: CREDIT CARD 040099 Printed: Tuesday, August 25, 2015 11:32 AM 1 of 1 SYSTEMS Date Paid: Monday, August 10, 2015 Paid By: JEFF JOHNSON Pay Method: CREDIT CARD 014465 Printed: Monday, August 10, 2015 2:27 PM 1 of 1 • �srsreMs INSPECTION RECORD Retain a copy with permit ,' D INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: .. /I �V� Type of Inspection: 6LAle, Address: 5 Date Called: Special Instructions: Date Wanted: 1 a. i lW .m. Requester: Phone No: 2-�yg EJ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0690 DATE: 08/10/15 PROJECT NAME: CENTURYLINK SITE ADDRESS: 6101 S 180 ST X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: kFf qln �t Building Division a Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 08/11/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DUE DATE: 09/08/15 Approved with Conditions x Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 MCCOY ELECTRIC CO INC 11 Page 1 of 2 kiWashington State Department of Labor & Industries MCCOY ELECTRIC CO INC Home Inieio en Espanol Contact Safety Search L&I ilZilsJ A-Z Index .Help My Secure L&I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 2014 SE 9TH AVE PORTLAND,OR Principals 503-234-7521 Landon, Jason J, PRESIDENT Landon, Ryan M, TREASURER CT CORP SYSTEMS, AGENT LANDON, MAX N, PRESIDENT (End: 12/17/2012) LANDON, MARLENE A, TREASURER (End: 12/17/2012) Doing business as MCCOY ELECTRIC CO INC WA UBI No. Business type 600 089 036 Corporation Governing persons JASON J LANDON MARLENE A LANDON; MAX N LANDON; RYAN M LANDON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ................................._.........._............... Meets current requirements. License specialties GENERAL License no. MCCOYEC381JT Effective — expiration 04/30/1962— 07/30/2017 Designated administrator ................... Armstrong, Zachary D License type Master Electrician Bond ........_....... DEVELOPERS SURETY & INDEM CO Bond account no. 849755C Received by L&I 12/16/2005 Active. Meets current requirements. License no. ARMSTZD880P5 $4,000.00 Effective date 01 /07/2006 Expiration date Until Canceled https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=600089036&LIC=MCCOYEC381JT&SAW= 8/25/2015 SITE PLAN SOUTH 180TH STREET 9' uTILrnES EASEMENT A.F. 6405583 " R=50 L = 83.41 p = 95 35' 05" `e RECYCLING AREA o i P_ T U ILA CYBER CENTER cc W 3 I 1 l IS, 6101 SOUTH 180TH.-STREET b, to : % r �: ., !• ,: / ,/ :: F / ,' : ,•/ .: ,r ! / i ° ' ! f ! 'r• / ,/ / ,f / � ` : � , /' % ,` /,/ F ,// %+/ ,f ,a /'/ �' , , /. . %/. /, // J. //.'./ /; :' f J , , /, //. ;/. , .%' , • //i/.•••/. / f i'' . %, .'r':'•f,•� //% r. ;'lf , // / . .• .i ,%/. • , .• /, , /,•'' .: /. ./, / . . �/. i1,'/i�r, /•,', , , ,�• .• . , � � i!• %/, i;�•, I 0 ' . / 20' WATER ESMT --� Z - CL TUKWILA WASHINGTON 98188 1 ____:-_-__ fi GENERATOR AREA OF WORK W ------ COURTYARD CENTURYLINK _- BLDG ._.___.......__._._..__.,_ ' SEATTLE TRANSPORT SWITCH SITE ;r ENTRY C) - - - 0101 SOUTH 180TH STREET r -' 2170020 S.F. f 0 0 LOADING DOCK LOADING DOCK -'-il -�-__./ '� • ; ., ,/% ; j ' // /,••'• %.l: /r' � • • .:!; f , % o','.•••/,// i';%; ,�% j; • ; '/, , / , / ' %�f%'',�''�,. i:rFi%'f'�'. r, ;` . ', / ; ,, . , ; 'r'.'%' I /' �/" rf�• -� ••/ ;', %�%'� FJ' F/F% /J•l /%! ! !'`fi� /!'' ; f. ZL /1 // i //:i�/i•'� r' !; fFf' ' ,%i lri ,'1.. ./� /, /; `� -- / � i ddddl C / SST t�02t6 FILE COPY Permit No. S E G A L E PARK DRIVE D Plan review approval is subied to and omissions. pn�tal fif, constnxtion dotxt duos not authorize the ' 'on of adopted aWs ordinem. Receipt Of R txlrt s is acknowt PLAN NORTH REVISMS No changes shall be made to the scope SITE PLAN of work without prior approval! of Tukwila Building Division. City of Tukwila SCALE: �' = 40' : Revisions will require a new plan suWMal BUILDING DIVISION and may in ude additiorsat plan review fees � GENERAL NOTES ABBREVIATIONS GRAPHIC SYMBOLS VICINITY MAP SUMMARY OF WORK ISSUES REVISIONS A. THE ADDITION OF ONE 50-TON DX ROOF -TOP AIR N0. DESCRIPTION DATE BY ABV. ABOVE ___._._. ._ _._._ 1. DO NOT SCALE DRAWINGS: 7. WEATHERPROOFING: MAX. MAXIMUM _ _... 2 ....-._.................. THE CONTRACTORS SHALL DETAIL TWO EXHAUST _ USE DIMENSIONS SHOWN ON THE DRAWINGS ALL OPENINGS, FLASHING, COUNTERFLASHING AND A.F.F. ABOVE FINISH C A-4 HANDLER, TWO 20,000-CFM ROOF -TOP MECH. MECHANICAL - Y i w AND ACTUAL FIELD MEASUREMENT. NOTIFY THE ARCHITECT IF ANY EXPANSION JOINTS SHALL BE CONSTRUCTED IN SUCH A MANNER AS DRAWING FOUR r �00-CFM 1 60% OWNER REVIEW 04/07/15 RJJ TO MAKE IT WEATHERPROOF. FLOOR MFR. MANUFACTURE FANS (ECONOMIZER RELIEF), AND ONE 6,5 _ _- ____ _.------- DISCREPANCIES ARE FOUND. FO WEATHERPROOFING DURING THE ALUM. ALUMINUM MIN. MINIMUM: SITE = BATTERY ROOM EXHAUST FAN. 2 100% OWNER REVIEW =�':;' 5 15 15 RJJ B. PROVIDE FOR ALL TEMPORARY :_ , � �. �__:.._, � _ SEPARATE F,.. __ _.:... _ MISC. MISCELLANEOUS a ,; E B. ECONOMIZER CONVERSION OF TWO EXISTING 2. DIMENSIONS: COURSE OF WORK TO ASSURE PROTECTION AND FULL OPERATION OF WALL SECTION B A. TRO HLY REVIEW ALL PLANS. VERIFY ALL DIMENSIONS AND THE EXISTING FACILITY. BD. BOARD MTL. METAL A-6 DRAWING SIX Ff r:, ,�'a�"r ROOF -TOP UNITS. 3 BID SET REC UIR�,D L~C3R. 5/18/15 ;RJJ CONDITIONS BEFORE STARTING WORK. NOTIFY ARCHITECT OF ANY BLDG. BUILDING r , C. EXPANSION OF THE BATTERY ROOM INTO PORTIONfilteect�arncat DISCREPANCIES. 8. BUILDING AND EQUIPMENT: N.I.C. NOT IN CONTRACT a` , OF EXISTING LOADING DOCK, APPROXIMATELY 200 D Electrical 6 - B. VERIFY LOCATION AND DISPOSITION OF EXISTING AND PROPOSED F DEBRIS ACCUMULATION. KEEP WORK AREAS ELEVATION B _____ _ MECHANICAL ELECTRICAL AND DATA UTILITIES AFFECTED BEFORE NEAT AND ORDERLY AS MUCH AS REASONABLY POSSIBLE. CLG. CEILING N0. NUMBER _6 y...y SQ �, Plumbing DRAWING SIX ` CLR. CLEAR N.T.S. NOT TO SCALE s. STARTING WORK. B. PROVIDE DUST PROTECTION FOR AREAS THAT WILL REMAIN OCCUPIED D. DUCTWORK MODIFICATIONS.'GasPiping r _. C. DIMENSIONS ON PLANS ARE TO FINISH FACE OR CENTERLINE OF DURING CONSTRUCTION INCLUDING, BUT NOT LIMITED TO THE CONC. CONCRETE �� . COLUMNS UNLESS NOTED OTHERWISE. FOLLOWING: TEMPORARY SEALS ON DOORS TEMPORARY DUST CONT. CONTINUOUS O.A. OVERALL XXX DOOR NUMBER E. FIRE/SMOKE DAMPERS, Cjtj of Tukv.,ila REMOVAL AND ADDITIONAL F KE .DAMP RELOCATION OF HEAT DETECTORS FIRE ALARM D. DIMENSIONS TO DOOR OPENINGS ARE TO JAMB OPENING IN STUD PARTITIONS, AND TEMPORARY FILTRATION ON RETURN/SUPPLY CONTR. CONTRACTOR O.C. ON CENTER - " `'== " `= WALLS. GRILLES. OPNG. OPENING PROGRAMMING MODIFICATIONS. �,,, �b"sham,ot,, 1600 71H AVE, SEAM& WASFWIM drford b madwbd p.m R b moat for w C. CONTRACTOR TO REMOVE ALL MATERIALS NOT RELATED TO THE DBL. DOUBLE NORTH ARROW F. RELOCATION OF SPRINKLER PIPING AT ROOF WXEOFiFE�t.aROPF NMW. gma.bemp.wAber.aa�ut 3. COORDINATION: FINISHED PRODUCT FROM THE SITE ON A DAILY BASIS OR PER THE , ` PENETRATIONS. ACTOR SHALL BE RESPONSIBLE FOR VERIFICATION AND OWNER'S REQUIREMENTS . EACH . DET• DETAIL PLYWD. PLYWOOD0DRSULTANT FIRM COORDINATION WITH OTHER TRADES. MATERIALS TO B USED. DIA. DIAMETER PR. PAIR XXX ROOM NUMBER}, G. STRUCTURAL WORK FOR SUPPORT OF THE NEW RTU D. NO ASBESTOS OR ASBESTOS CONTAINING MATER L E U E DW 8 r SOS I E N B. CONTRACTORS SHALL VERIFY SIZES AND LOCATIONS OF ALL DIM. DIMENSION AND ECONOMIZER EXHAUST FANS. �:.:. . OPENINGS FOR MECHANICAL EQUIPMENT WITH MECHANICAL �; 10202FfthAvenueNE,Suite3oo 9. BLOCKING: DR. DOOR REINF. REINFORCING s..- H. SUPPORTING CONTROLS, ELECTRICAL WORK, �ti - Seattle, Washington 98125 CONTRACTOR AS WELL AS WITH APPROVED SHOP DRAWINGS, BEFORE PROVIDE SOLID BLOCKING FOR ALL WALL MOUNTED FIXTURES, REQD. REQUIRED " - STRUCTURAL STEEL, AND ROOFING WORK. p.2o6.547.1940 f.206.547.8212 PROCEEDING WITH THE WORK. C. WHERE INSTALLATION AND/OR CONNECTION OF EQUIPMENT IS NOT DEVICES &EQUIPMENT. COORD. W/ MECHANICAL &ELECTRICAL TO EA, EACH R.O. ROUGH OPENING WED.FOR SPECIFIED BUT SUCH CONNECTION AND/OR INSTALLATION IS VERIFY LOCATION REQ D. ELEC. ELECTRIC CODE NOTES LEGAL DESCRIPTION SHEETINDEX i -COMPLIANCE-- - _ - I RECEIVED REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM, THE 10.ASBESTOS: ELEV. ELEVATION SCH. SCHEDULE NFPA70 - NEC CITY OF TUKWILA CONTRACTOR SHALL BE HELD RESPONSIBLE FOR SUCH CONNECTION A. NO M ERIALS CONTAINING ASBESTOS ARE TO BE USED. EQ. EQUAL SHT. SHEET G0.1 COVER SHEET SITE PLAN &GENERAL INFO AND/OR INSTALLATION. B. IF MATERIALS ARE DISCOVERED ON SITE THAT APPEAR TO CONTAIN EXIST. EXISTING SIM. SIMILAR ZONE: TUKWILA URBAN CENTER PARCEL NO. 3523049120 AUG 14 2015 AUG 10 2015 ASBESTOS, WORK IN THAT AREA IS TO STOP IMMEDIATELY. OWNER IS EXT. EXTERIOR SPEC. SPECIFICATION 4. ABBREVIATIONS: TO BE NOTIFIED AT ONCE. WORK IS NOT TO RESUME UNTIL MATERIAL STL. STEEL OCCUPANCY: B DATA CENTER PORTION OF LOT 2 OF CITY OF TUKWILA SHORT PLAT A1.1 FLOOR PLAN PERMIT CENTER 0 HE PLAN ARE ABBREVIATIONS WHICH ARE OF COMMON HAS BEEN CONTAINED, REMOVED, AND/OR DETERMINED TO BE FREE ( ) A1.2 PARTIAL DEMO AND NEW FLOOR PLANS USE. THE LIST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE FROM ASBESTOS. F.F. FINISH FLOOR STD. STANDARD NO 86-45 SS RECORDING NO 8609081152 AS City of _Tukwila COMPLETE OR REPRESENTATIVE OF ALL CONDITIONS OR MATERIALS FLR. FLOOR SYS. SYSTEM BUILDING AREA: 89,250 SF AMENDED BY CITY OF TUKWILA LOT LINE ADJ NO A1.3 PARTIAL DEMO AND NEW CEILING PLANS UILDING DIVISION' ACTUALLY USED ON THE PROJECT. THE ARCHITECT WILL DEFINE THE 11.EXAMINATION OF BIDDING DOCUMENTS: F.T. FIRE TREATED 93-0085 RECORDING 'NO 9311301961 AS LOT 3 DAF A1.4 PARTIAL ROOF PLAN INTENT OF ANY IN QUESTION. A. EACH IDDERS BIDDING DOCUMENTS CAREFULLY THK. THICK BUILDING HEIGHT: ONE STORY - PORTION OF SW 1/4 OF NE 1/4 - BEGIN NW A4.1 DETAILS AND, NOT LATER THAN SEVEN DAYS PRIOR TO BID DUE DATE, SHALL GA. GAUGE TYP. TYPICAL A4.1 DETAILS 150241 CODES: MAKE REQUESTS FOR INFORMATIONVCLARIFICATION OF ANY CORNER OF SW 1/4 OF NE 1/4 TH S 87-50-09 E ACC�I�RK SHALL CONFORM TO APPLICABLE BUILDING CODES AND DISCREPENCIES, AMBIGUITY, INCONSISTENCY OR ERROR THEREIN GALV. GALVANIZED CONSTRUCTION TYPE: II-B 449.30 FT TH S 02-09-51 W 36 FT TO S MGN OF �ILaNc ID FlooR ORDINANCES. IN CASE OF ANY CONFLICT WHEREIN THE METHODS OR WHICH HE MAY DISCOVER UTILIZING THE CENTURYLINK MESSAGE U.N.O. UNLESS NOTED S1.1 STRUCTURAL NOTES &OVERALL ROOF PLAN ®® ®® STANDARDS OF INSTALLATION OR THE MATERIALS SPECIFIED DO NOT S 180TH ST & POB TH S 87-50-09 E 786.92 FT TH ®. ® BUILDING NAPE BOARD BIDMASTER. ANY INTERPRETATION OR CORRECTION WILL BE HT. HEIGHT OTHERWISE S2.1 PARTIAL ROOF FRAMING PLANS ® TUKWILA CYBER CENTER EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, ISSUED UITILIZING THE CENTURYLINK BIDMASTER MESSAGE BOARD. HVAC HEATING/VENTILATING CLIMATE ZONE: 1 (WASHINGTON STATE ENERGY CODE) ALONG CURVE TO RIGHT RADIUS OF 50 FT THRU C/A S3.1 DETAILS �® ®®T Aoo 6101 SOUTH 180TH STREET THE LAWS AND ORDINANCES WILL GOVERN. NOTIFY ARCHITECT OF ALL c NO BIDDER SHALL RELY UPON INTERPRETATIONS OR CORRECTIONS AIR CONDITIONING W/ WITH 4C (INTERNATIONAL ENERGY CODE) OF 95-35-05 ARC DISTANCE OF 83.41 FT TH S CONFLICTS. GIVEN BY ANY OTHER METHOD. IF DISCREPANCIES, AMBIGUITY, Centu Link «TM. sA� TUKWILA, WASHINGTON 98188 INCONSISTENCY OR ERROR ARE NOT COVERED BY ADDENDUM OR HORIZ. HORIZONTAL WT. WEIGHT 07-44-56 W 348.56 FT TH N 87-50-09 W 802.76 M0.1 MECHANICAL LEGEND AND NOTES 6. PROVIDE ALL REQUIRED PERMITS: WRITTEN DIRECTIVE CONTRACTOR SHALL INCLUDE IN HIS BID THE APPLICABLE CODES: 2012 INTERNATIONAL BUILDING CODE ** FT TH N 02-09-51 E 401.77 FT TO POB --- LOT M1.1 MECHANICAL DEMOLITION PARTIAL FLOOR PLAN �' A. T�GH�T-R/�S�/ APPLIED -FOR AND MADE DEPOSIT ON THE LABOR, MATERIALS, AND METHODS OF CONSTRUCTION RESULTING IN INSL. INSULATION CENTERLINE 2012 INTERNATIONAL EXISTING BUILDING CODE 3 OF CITY OF TUKWILA LOT LINE ADJ NO 93-0085 M2.1 MECHANICAL PARTIAL FLOOR PLAN COVER SHEET, SITE PLAN & GENERAL INFORMATION BUILDING AND MECHANICAL PERMIT. THE CONTRACTOR SHALL HIGHER COST. AFTER AWARD OF CONTRACT, NO ALLOWANCE OR R PROPERTY LINE 2012 INTERNATIONAL FIRE CODE ** RECORDING NO 9311301961 --- LESS RR R/W M2.2 MECHANICAL PARTIAL ROOF PLAN PROVIDE ALL ADDITIONAL PERMITS. EXTRA COMPENSATION WILL BE MADE ON BEHALF OF THE LOC. LOCATION 2012 INTERNATIONAL MECHANICAL CODE ** B. ALL POSSIBLE RIGHT-OF-WAY WORK TO BE PER LOCAL JURISDICTION CONTRACTOR DUE TO HIS FAILURE TO MAKE THE WRITTEN REQUESTS ESMT IN NE 1/4 & SE 1/4 (OPERATING PROPERTY) M5.1 MECHANICAL DETAILS AND DIAGRAMS NA 2012 UNIFORM PLUMBING CODE DEPARTMENT OF ENGINEERING STANDARDS. AS DESCRIBED ABOVE. ** coNsuLTANr NAPE coNsuLTANNAME C. WORKING HOURS FOR THE USE OF LOUD EQUIPMENT SHALL BE B. THE PERSON SUBMITTING THE REQUEST WILL BE RESPONSIBLE FOR 2011 NATIONAL ELECTRIC CODE ** EO.1 ELECTRICAL LEGEND AND NOTES KDW SAAAS O'BRIEN LIMITED TO TIMES ESTABLISHED BY THE LOCAL JURISDICTION AND ITS PROMPT DELIVERY. ` FAILURE TO SO REQUEST CLARIFICATION OF 2012 WASHINGTON ENERGY CODE E2.1 ELECTRICAL PARTIAL FLOOR PLANS ACCORDING TO THE OWNER'S REQUIREMENTS. THIS EQUIPMENT SHALL ANY INADEQUACY, OMISSION, OR CONFLICT WILL NOT RELIEVE THE FAA- A C nturyLink KW INCLUDE BUT IS NOT LIMITED TO GENERATORS, COMPRESSORS, CONTRACTOR OF RESPONSIBILITY. E2.2 ELECTRICAL PARTIAL ROOF PLAN W.4m Br JF USE NUMB JOB 140. DRILLS, RADIOS, AND OTHER SIMILAR EQUIPMENT. C. ** WITH STATE AND LOCAL AMENDMENTS 150241 CCONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND VERIFY THAT DATE 04/07/2015 CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN HIS DECM BID THE COSTS REQUIRED TO MAKE HIS WORK MEET EXISTING �' JO MA1RNG No SHEEr No CONDITIONS. REIAM Br MSK GO.1 SC&E ..... _. _,..._-.......- ... ......:....Y ,1..-u. FOR -1 =WITH NEC 1015 wila VISION