Loading...
HomeMy WebLinkAboutPermit EL15-0699 - BOEING EMPLOYEES CREDIT UNION (BECU) - SWITCHES, RECEPTACLES, PANELS, HOT WATER TANKS ETCBECU 12770 GATEWAY DR ELl 5=0699 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 2716000075 Permit Number: EL15-0699 Address: 12770 GATEWAY DR Issue Date: 9/15/2015 Permit Expires On: 3/13/2016 Project Name: BECU Owner: Name: BOEING EMPLOYEES CREDIT UNI Address: PO BOX 97050, SEATTLE, WA, 98124 Contact Person: Name: DARREN BROCKSMITH Phone: (206) 383-7010 Address: 12828 NORTH UP WAY, STE 205, BELLEVUE, WA, 98005 Contractor: Name: TITAN ELECTRIC INC Phone: (206) 633-2811 Address: 12828 NORTHUP WAY SUITE 205, BELLEVUE, WA, 98005 License No: TITANE19630B Expiration Date: 9/2/2016 Lender: Name: Address: DESCRIPTION OF WORK: TENANT IMPROVEMENT: LIGHTS SWITCHES, RECEPTACLES, PANELS, HOT WATER TANKS, MECHANICAL UNITS AND INTERIOR FURNITURE CONNECTIONS Valuation of single family: $0.00 Fees Collected: $24,322.02 Valuation of mf/comm: $2,653,710.00 Type of Work: TENANT IMP Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature:"I ( Date: / - I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other ng co ruction or the performance of work. I am authorized to sign and obtain this state or local laws regyl/i development permit d agW to the conditions attached to this permit. Date: Print This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKH Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httl2://www.TukwilaWA.gov Electrical Permit No. Project No. _ Date Application Accepted: --A Date Application Expires: !� For office use only ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 271600-0075 Site Address: 12770 Gateway Drive Tukwila, WA 98168 Suite Number: Floor: 1 thru 6 Tenant Name: BECU/Tukwila Financial Center New Tenant: ❑ .....Yes ®.. No PROPERTY OWNER Name: BECU/Tukwila Financial Center Address: 12770 Gateway Drive City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Darren Brocksmith Address: 12828 Northrup Way Suite 205 City: Bellevue State: WA Zip: 98005 Phone: (206) 383-7010 Fax: (206) 374-2128 Email: darrenb@titanelectric.net ELECTRICAL CONTRACTOR INFORMATION Company Name: Titan Electric Address: 12828 Northrup Way Suite 205 City: Bellevue State: WA Zip: 98005 Phone: (206) 633-2811 Fax: (206) 374-2128 Contr Reg No.: TitanEI9630B Exp Date: 09/02/2016 Tukwila Business License No.; BUS-0992893 Valuation of Project (contractor's bid price): $ 2,653,710 Scope of Work (please provide detailed information): Tenant Improvement, Lights,Switches, Receptacles,Panels Hot Water Tanks,Mechanical Units, Inter Furniture Connections Will service be altered? Type of Use: ❑ Yes m No Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy 0 Seattle City Light H: Applications Forms -Applications On Line 2014 Applicat ions Electrical Permit Application Revised I-I-14.docx Revised: January 2014 bh Adding more than 50 amps? Z Yes ❑ No ❑ Remodel ® Tenant Improvement ❑ Telecommunication ❑ Temporary Service Pagel of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings...................................$152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $1 1.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals....................................................................$80.60 Number of concessions ......................... $ l 0.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: -O&V / e4oy 23200444 Date: 08/12/2015 Print Name: Darren Brocksmith Day Telephone: (206) 633-2811 Mailing Address: 12828 Northrup Way Bellevue WA 98005 City State Zip HrApplications:Forms-Applications On Line:2014 Applications Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $19,644.71 EL15-0699 Address: 12770 GATEWAY DR Apn: 2716000075 $19,644.71 ELECTRICAL $18,709.25 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $18,709.25 TECHNOLOGY FEE $935.46 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6163 R000.322.900.04.00 0.00 $935.46 $19,644.71 Date Paid: Tuesday, September 15, 2015 Paid By: TITAN ELECTRIC INC Pay Method: CHECK 19588 Printed: Tuesday, September 15, 2015 1:01 PM 1 of 1 SYSTEMS DESCRIPTIONS PermitTRAK ACCOUNTQUANTITY PAID $4,781.68 EL15-0698 Address: 12770 GATEWAY DR Apn: 2716000075 $104.37 ELECTRICAL $99.40 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $99.40 TECHNOLOGY FEE $4.97 TECHNOLOGY FEE R000.322.900.04.00 0.00 $4.97 EL15-0699 Address: 12770 GATEWAY DR Apn: 2716000075 $4,677.31 ELECTRICAL $4,677.31 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R5929 R000.345.832.00.00 0.00 $4,677.31 $4,781.68 Date Paid: Wednesday, August 12, 2015 Paid By: TITAN ELECTRIC INC Pay Method: CHECK 19390 Printed: Wednesday, August 12, 2015 3:06 PM 1 of 1 SYSTEMS INSPECTION RECORD2-7- �( Retain a copy with permit INSPECTION NO. P MIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: _ Type of Inspection: Address: � �� Date Called: Special Instructions: Date Wanted: a.m. .m. Requester: Phone No: 1093671 ill Approved per applicable codes. LJ Corrections required prior to approval. Inspector:Date: (� 11d)J1` ( 0 REINSPECT104 FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedute reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 96W Type of Inspection: c r N �> Address: 2,770 L � Date Called: Special Instructions: Date Wanted: a.rrs. Requester: Phone No: 702 3671 ❑ Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: -- _ COO/N(T' `—' paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: ya 4 Date Called: Special In tructions: Date Wanted: f a.m l .m. Requester: Phone No: Z -1602 , Approved per applicable codes. E Corrections required prior to approval. COMMENTS: VA Inspector: t N Date: pr n 2 r� REINSPECTIONIrEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD � Retain a copy with permit I INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: a�� Type of Inspection:Ail-/ r Address: Z7 Date Called: Special Instructions: t Date Wanted: .m. Requester: Phone No: �t 2, 7T6 Z— Approved per applicable codes. 1:1 Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit Q INSPECTION NO. PER N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: , Address: / Ma Date Called: Special Instructions: Date Wanted: a.m. J07,1 Requester: Phone No: .. I r Approved per applicable codes. Corrections required prior to approval. U paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: S(C4) Type of Inspection: D �� � l Address:1Z7 Date Called: Special Instructions: Date Wanted: a.m. Requester: A� !� fr Phone No: 2�3 z2 Approved per applicable codes. Ll Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.; #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection:• Address: /LZ ® � Date Called: Special Instructions: Date Wanted: a. p.m. Requester: Phone No: Approved per applicable codes. 11 Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit fi4 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection&4024966) Address: ,,, 7701�1 Date Called: Special Instructions: r I Date Wanted: 1 � P.m. Requester: Phone No: ,`— Approved per applicable codes. El Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit b INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., 4100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection:M � Address: a 7 7 0 68 Date Called: -r�� Special Instructions: Date Wanted: a p- VJ10 Requester: Phone No: (L4 �( Approved per applicable codes. Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS PEFT-1 0N N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspectio cik N Address: �7�� C�� Date Called: Special Instructions: I 2,1� Date Wanted: ® a._. .m Requester: Phone No: YZ2-��� Approved per applicable codes. Corrections required prior to approval. u paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. # I INSPECTION RECORD Retain a copy with permit I r--069 fl INSPECTION NO. PERMIT NC CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: _ r Address: l2�77(2'. Date Called: Special Instructions: Date Wanted: a., 4 p.m. Requester: Phone No: ElApproved per applicable codes. LJ Corrections required prior to approval. " paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �Q INSPECTION RECORDj� v Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: F Type of Inspection: . Address:/2-710 CtolJm Date Called: Special Instructions: Date Wanted: ^ 7 a b p.m. Requester: Phone No: C � •.� Approved per applicable codes. Ll Corrections required prior to approval. lJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPEC ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: ^,770 14 Ftr Date Called: Special Instructions: Date Wanted: a.m M. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: el tn%1�t� if Fuoo L I ^l* Co kc1Cg-t0 "!) MD /°-1— I —I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD ` Retain a copy with permit 'a INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: &l./�' Type of Inspection: k/4 If (,A] Address: / �� 12,7764T t v" Date Called: Special Instructions: Date Wanted: a.m Z, p.m. Requester: Phone No: ❑ Approved per applicable codes. 11 Corrections required prior to approval. U paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD164 5�-L% fl 6 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: &{ Type of Inspection: Address: 2- o 6Jj[:6d14 Date Called: Special Instructions: Ow C' '- `I� �� Date Wanted: a.m Requester. Phone No: �-- t12- I Approved per applicable codes. Corrections required prior to approval. '-' paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Q Retain a copy with permit ` INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: fl JGu � Address: 1�719 Date Called: Special Instructions: Date Wanted: a.m p.m. Requester: L Phone No: / G� Approved per applicable codes. 11 Corrections required prior to approval. L __I paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit(P5�-06j� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request line (206) 438-9350 99 Project: G ) Type of Inspection: � Address: /L?? o Date Called: Special Instructions: D LID Date Wanted: 2 a.m Requester: Phone No: Approved per applicable codes. Corrections required prior to. approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD /lo Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:j1 CIL Type of inspection: Address: f® Date Called: Special Instr��uctions: Date Wanted: a.m. 5 �2,. Requester. Phone No: n U Approved per applicable codes. E Corrections required prior to approval: u paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. r INSPECTION RECORD l Retain a copy with permit INSPE TION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206 431-3670 Permit Inspection Request Line (206) 438-9350 efAt-- Project: / Type of Inspection:vo�fj �� Address: `']� Date Called: Special Instructions: Date Wanted: 3 a P.m Requester: Phone No: Approved per applicable codes. IX,I Corrections required prior to approval. COMMENTS: AL it - up �>Pkrlh-- 'SCl-E D J1, REINSPECTION PEE REQUIRED. Prior to next inspection, fee'must be paid at 6300 Southcenter Blvd.. Suite 100. Cal[ to schedule reinspection. Lo INSPECTION RECORD Retain a copy with permit`��� INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-93�p- Project: I Typ Irjsn: fY—Cd `+ Address: 2-770 Date Called: Special Instructions: I Date Wanted: a.m p.m. 7 Requester: ! Phone No: Z!�q —1 Approved per applicable codes. 1-1 Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit _ IQ INSPE ION N0. PFRMII NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: / Address: 7 v 44J j Date Called: Special Instructions: zFao-Zra 3 '1-to2 Date Wanted: a.m Requester: r Phone No: < Z�- Z5 y ❑ Approved per applicable codes. LJ Corrections required prior to approval. u REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � Type of lnspectio Address: ,� 770 Date Called: Special lnstructions: Date Wanted: a.m C P.M. Requester: Phone No: ^ (/ 2— Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD f 9q 7 etain a copy with permit Cam' I r INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � Type of Inspectio Address: 2- 0) 6 Date Called: Special Instructions: f Date Wanted: a.m. 9A Requester: Phone No: ElApproved per applicable codes. 1-1 Corrections required prior to approval_ u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �� � Type of Inspection: �10 Address: 12M) 6W,<LJA Date Called: Special Instructions: I Date Wanted: a.m p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: VA Inspector: Date: -iM V02�' I o(/'( � El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD��� Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., 4100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Mcd Type of Inspectio . v� G{- Address: 1Z77® Date Called: Special Instructions: 5. Pk Date Wanted: a Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD q Retain a copy with permit I INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 A Project: 6&lk/ Type of Inspection: _ I IN Address: 27 ® C5 Date Called: Special Instructions: - '� Mt'1/ ��f'�/�� �lCp� Oft- Date Wanted: © a.m. !� Requester: Phone No: �- 2s Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: W Mq i c7 LASISI REINSPECTI0N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD -3 Retain a copy with permit 164 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: 2771b Date Called: Special Instructions: I % p4j63 Date Wanted: a.m M. Requester: Phone No: r2- l` nApproved per applicable codes. LJ Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedute reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 w Project: Type of Inspection: Address: b 4ff Date Called: Special Instructions: Date Wanted: a.m It Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: / _ , Type of inspection: ®04 Address: Date Called: Special Instructions: Date Wanted: La�— a. M. Requester: Phone No: 2�—, Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 4/3/2017 DARREN BROCKSMITH 12828 NORTHUP WAY, STE 205 BELLEVUE, WA 98005 RE: Permit No. EL15-0699 BECU Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/22/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. if it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/22/2017. your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, W Rachelle Ripley Permit Technician File No: ELI5-0699 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 9 Phone 206-431-3670 • Fax 206-431-366.5 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0699 DATE: 08/17/15 PROJECT NAME: BECU SITE ADDRESS: 12770 GATEWAY DR X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued 10U.1.1'ANUT IDQU W im w- � ,i Building Division 12 Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 08/18/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/15/15 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 TITAN ELECTRIC INC Page 1 of 4 Home Inicio en rspanol Contact Safety Washington State Department of Labor & Industries TITAN ELECTRIC INC Owner or tradesperson Principals BURKE, PATRICK D, PRESIDENT CROOK, TRAVIS J, VICE PRESIDENT FUNG, LAWRENCE H, SECRETARY FUNG, LAWRENCE H, AGENT Doing business as TITAN ELECTRIC INC Search L&I A-Z Index Help :fly Secure L,&I Claims & Insurance Workplace Rights Trades & Licensing 12828 Northup Way Suite 205 BELLEVUE, WA 206-633-2811 KING County WA UBI No. Business type 602 250 925 Corporation Governing persons LAWRENCE M FUNG PATRICK DUNIVON BURKE; TRAVIS JAY CROOK; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. TITANE19630B Effective — expiration 09/02/2004— 09/02/2016 Designated administrator Active. CROOK, TRAVIS Meets current requirements. License type License no. Electrical Administrator CROOKT'011 PB Bond ................. Lexon Ins Co $4,000.00 Bond account no. 9808431 Received by L&I Effective date 08/08/2011 08/03/2011 Expiration date Until Canceled Bond history 1.Savings No savings accounts during the previous 6 year period. License Violations https:Hsecure.Ini.wa.gov/verifyIDetail.aspx?UBI=602250925&LIC=TITANEI963OB&SAW= 9/15/2015 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Nov 2013 Project Info Project Address BECU TUKWILA Date 7/22/2015 Compliance 12770 GATEWAY DR For Building Department Use forms do not require a TUKWILA, WA 98168 password to use. Applicant Name: CASE ENGINEERING Instructional and calculating cells Applicant Address: 19515 NORTH CREEK PKWAY, SUITE 302, BOTHELL WA Applicant Phone: 425-402-9400 are write- Project Description) New Building D Addition [1 Alteration ❑ Plans Included Lighting Compliance Path Lighting Power Density Calculations O Total Building Performance (1f Total Building Performance then only LGT-CHK is required.) Lighting Power Allowance O Building Area Method Q Space -By -Space Method Method Selection required to enable LPA forms Interior Lighting System Description Briefly describe lighting system type and features. Additions and Change of Space Use (C101.4.3 & C101.4.4) ❑ Addition area or Change of Space Use area complies with all applicable provisions as stand alone project Ei Addition area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions per C101.4.3 Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) [1] 60% or more of luminaires in space replaced Provide Building Area Method (LTG-INT BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Retrofit and non -retrofit spaces shall be documented separately using multiple forms. Less than 60% of luminaires in space replaced Provide a separate Space -By -Space Method (LTG-INT SPACE) Compliance Form for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage table. Lamp andror ballast replacement within existing luminaires only - existing total Interior building wattage not increased New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 ( New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2. I;, and commissioning of lighting controls per C405.13. C Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. No changes are being made to the interior lighting and space use not changed. Stnfa Fnarnv Coda r.mmnlianCe Forms for CnmmarriA Huddinos inrludinn R2 & R3 over 3 stories and all R1 Revised Nov 2013 Project Address BECU TUKWILA Date 7/22/2015 Lighting Alterations, Renovations & Building Additions O Less than 60% 0 60% or more O Stand alone 0 Addition fixtures replaced fixtures replaced bldg. addition Notes: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing bldg lighting to demonstrate compliance. Refer to C t 01.4.3. b. For retrofits and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall existing builidng, include ad applicable existing Space Types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 60% of existing fixtures will be replaced, provide total existing lighting wattage (prior to retrofit) in the space provided in the Maximum Allowed Lighting table. For Building Department Use Maximum Allowed Lighting Wattage Location (plan #,Allowedross room #, or ALL) Space Type` Watts per ft` n error Area in fe a s owe (watts/112 x area) Sates area 1.68 9285 15599 Office - Enclosed 1.11 35941 39895 Office - Open plan 0.98 61686 60452 Corridorltransition 0.66 5405 3567 Conference/meeting/multipurpose 1.23 8174 10054 Storage 0.63 613 386 Dining area: Badloungollolsure dining 1.31 3720 4873 Atrium"' Enter Height,' Existing Lighting ` Enter Exist. Watts: Retail Display Allowance from LGT-INT-DISPLAY ` Select Table C405.5.2(2) category from drop down menu. " For atriums, indicate height. Allowed wattage for first 40 feet is 0.03 Wlft. ht., above 40 feet is 0,02 Wlft. ht. Proposed Li- hting Wattage Area Allowed Watts Totall 124824 134826 Location (plan #, room #, or ALL) Fixture Description- Number of Fixtures Watts/ Fixture Watts Proposed A -CABLE MTD 8' LINEAR LED 209 94 19646 B-WALL MTD 8' LINEAR LED 60 84 5040 C1-CABLE MTD 19' LED 1 129 129 C2-CABLE MTD 27' LED 1 81 81 C3-CABLE MTD 20' LED 1 135 135 C4-CABLE MTD 16' LED 1 108 108 CS -CABLE MTD 24' LED 1 162 162 CT -CABLE MTD 8' LED 1 58 58 C8-CABLE MTD 16' LED 1 108 108 C9-CABLE MTD 23' LED 1 155 155 CIO -CABLE MTD 20' LED 1 135 135 C11-CABLE MTD 20' LED 1 135 135 C12-CABLE MTD 22' LED 1 148 148 D-CABLE MTD 12' LED 9 132 1188 E1-PENDANT MTD LED 43 11 473 E2.PENDANT MTD LED 91 11 1001 F-RECESSED 4" DIA LED DNLT 10 36 360 Fl-RECESSED 4" DIA LED WALL WASHER 4 36 144 "EMI RECESSED LED WALL WASHER 44 17 748 H-RECESSED LINEAR LED-76' 76 6 456 J-CABLE MTD MULTI LAMP LED ACCENT 12 87 1044 K1-CABLE MTD 8' LINEAR LED 43 98 4214 K4-CABLE MTD 4' LINEAR LED 6 49 294 L1-RECESSED 8' LINEAR LED 16 82 1312 1.2-RECESSED 6'LINEAR LED 9 31 279 1-3-RECESSED 4' LINEAR LED 17 40 680 L4•RECESSED I I' LINEAR LED 4 56 224 1.6-RECESSED 16' LINEAR LED 4 245 980 1.9-RECESSED 7' LED LINEAR SLOT 1 108 108 Lto-RECESSED 20' LINEAR LED 1 306 306 M-CABLE MTD 32" DIA DECORATIVE LED-3 LAMP 18 225 4050 P-CABLE MTD DECORATIVE iNCANCESCENT-1 LAMP 20 100 2000 R-RECESSED 2x2 LED TROFFER 36 37 1332 S-RECESSED 3.5" DIA DNLT LED 244 20 4880 U-WALL MTD LED ACCENT-1657' 1657 7 11599 U2A-CABLE MTD IT LINEAR LED 1 84 84 T-SURFACE MTD LiNEAR FLUOR COVE-1 LAMP 47 62 2914 VI -SURFACE MTD LINEAR LED 1 96 96 Y-SURFACE MTD FLUOR UNDER CABINET LT-1 LAMP 43 32 1376 W-CABLE MTD DECORATIVE LED CYLINDER LT 15 6 90 K2 -CABLE MTD 12' LINEAR LED 4 147 588 Retail Display Lighting frgrn LGT-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Wattl 688 bu I Include existing to remain lighting fixtures and exempt lighting equipment per notes below. Notes: 1. Include ALL proposed lighting fixtures. 2. For proposed Fixture Description, Indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 3. For proposed WattslFixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminafre wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. 4. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave WattslFixture blank. 5. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description. 6. if #NA appears in Retail Display cells, information on LTG-INT•DISPLAY is incomplete. (Interior Lighting Power Allowance CUMPLIES1 LIGHTING FIXTURE SCHEDULE WATTS/ TYPE DESCRIPTION LAMP FI XT INTERIOR A CABLE MOUNTED & LINEAR DIRECTIINDIRECT LED WITH 0-1OV DIMMING LED 94 DRIVER. B WALL MOUNTED 8' LINEAR DIRECTIINDIRECT LED WITH 0-1OV DIMMING LED 84 C1 CABLE MOUNTED 19' LINEAR DIRECTIINDIRECT LED WITH 90 DEGREE LED 129 CORNER. 0-10V DIMMING DRIVER. C2 CABLE MOUNTED 27' LINEAR DIRECTIINDIRECT LED WITH 90 DEGREE LED 81 CORNER. 0-10V DIMMING DRIVER. C3 CABLE MOUNTED 20' LINEAR DIRECTIINDIRECT LED WITH 90 DEGREE LED 135 CORNER. 0-10V DIMMING DRIVER. C4 CABLE MOUNTED 16' LINEAR DIRECTIINDIRECT LED WITH 90 DEGREE LED 108 CORNER. 0-10V DIMMING DRIVER. C5 CABLE MOUNTED 24' LINEAR DIRECTIINDIRECT LED WITH 90 DEGREE LED 162 CORNER. 0-10V DIMMING DRIVER. C6 CABLE MOUNTED 11'6" LINEAR DIRECTIINDIRECT LED WITH 90 DEGREE LED 78 CORNER. 0-10V DIMMING DRIVER. C7 CABLE MOUNTED 8' LINEAR DIRECT LED WITH 0-10V DIMMING DRIVER LED 58 C8 CABLE MOUNTED 16' LINEAR DIRECTIINDIRECT LED WITH 90 DEGREE LED 108 CORNER. 0-10V DIMMING DRIVER. C9 CABLE MOUNTED 23' LINEAR DIRECTIINDIRECT LED WITH 90 DEGREE LED 155 CORNER. 0-10V DIMMING DRIVER. C10 CABLE MOUNTED 20' LINEAR DIRECTIINDIRECT LED WITH 90 DEGREE LED 135 CORNER. 0-10V DIMMING DRIVER. C11 CABLE MOUNTED 20' LINEAR DIRECTIINDIRECT LED WITH 90 DEGREE LED 135 CORNER. 0-10V DIMMING DRIVER. C12 CABLE MOUNTED 22' LINEAR DIRECTIINDIRECT LED WITH 90 DEGREE LED 148 CORNER. 0-10V DIMMING DRIVER. D CABLE MOUNTED 12' LINEAR LED WITH 0-10V DIMMING DRIVER LED 132 E1 PENDANT MOUNTED LED WITH 0-10V DIMMING DRIVER LED 11 E2 PENDANT MOUNTED LED WITH 0-10V DIMMING DRIVER. LED 11 F RECESSED NOMINAL 4" DIAMETER DOWNLIGHT. LED. 0-10V DIMMING LED 36 DRIVER. F1 RECESSED NOMINAL 4" DIAMETER WALL WASHER. LED. 0-10V DIMMING LED 36 DRIVER. G SEMI RECESSED LED WALL WASHER, NOMINALLY 7-1I2" x 5" x 4-1I4". LED 17 0-10V DIMMING DRIVER. H RECESSED LINEAR PERIMETER SLOT LED WITH 0-10V DIMMING LED 6 DRIVER. PER FT J CABLE MOUNTED MULTI LAMP, ADJUSTABLE LED ACCENT LIGHT. LED 87 WiTH 0-10V DIMMING DRIVER. K1 CABLE MOUNTED & LINEAR LED WITH 0-10V 'DIMMING DRIVER. LED 98 K2 CABLE MOUNTED 12' LINEAR LED WITH 0-10V DIMMING DRIVER. LED 147 K4 CABLE MOUNTED 4' LINEAR LED WITH 0-1OV DIMMING DRIVER. LED 49 L1 RECESSED LINEAR 8' LENSED LED WITH 0-10V DIMMING DRIVER. LED 82 L2 RECESSED LINEAR 6' LENSED LED WITH 0-10V DIMMING DRIVER. LED 31 L3 RECESSED LINEAR W LENSED LED WITH 0-10V DIMMING DRIVER. LED 40 L4 RECESSED LINEAR 1 V LENSED LED WITH 0-10V DIMMING DRIVER. LED 56 L6 RECESSED LINEAR 16' LENSED LED WITH 0-10V DIMMING DRIVER. LED 245 L9 RECESSED LINEAR SLOT LIGHT 7' LED 108 L10 RECESSED LINEAR 20' LENSED LED WITH 0-10V DIMMING DRIVER. LED 306 M CABLE MOUNTED 32" DIAMETER DECORATIVE LED. 3-7W E26 225* P CABLE MOUNTED DECORATIVE INCANDESCENT PENDANT 1-10OW E26 100 NOMINALLY 13" HIGH BY 10" DIAMETER. R RECESSED 2x2 TROFFER WITH 0-1OV DIMMING DRIVER. LED 37 S RECESSED NOMINAL 3.5" LED DOWNLIGHT WITH 0-10V DIMMING LED 20 DRIVER. U WALL MOUNTED LED ACCENT LIGHT WITH 0-10V DIMMING DRIVER. LED 7 PER FT U2A CABLE MOUNTED 12' LINEAR SQUARE LED WITH 0-10V DIMMING DRIVER. LED 84 T SURFACE MOUNTED LINEAR FLUORESCENT COVE LIGHT. 1-54T51HO 62 PER 4'-0" V1 SURFACE MOUNTED LINEAR TRACK WITH LED MODULES 3" ON CENTER - 96 AND REMOTE 96W REMOTE DIMMING DRIVER PER 30'-0" Y SURFACE MOUNTED FLUORESCENT LINEAR UNDER CABINET LIGHT. 1-F28T5 32 PER 4'-0" W CABLE MOUNTED DECORATIVE CYLINDER LIGHT. NOMINALLY LED 6 3" DIAMTER BY 14" LONG. X1 UNIVERSAL MOUNT EDGELITE EXIT SIGN WITH GREEN STENCIL FACE. LED 5 *RATED WATTAGE OF FIXTURE ELECTRICAL SYMBOLS & ABBREVIATIONS LEGEND POWER RECEPTACLES & OUTLETS LIGHT FIXTURES & CONTROLS ABBREVIATIONS pO DUPLEX RECEPTACLE NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH, A (200A) (AFTER A NUMBER) = AMPS DOUBLE DUPLEX RECEPTACLE MOUNTING & EMERGENCY EGRESS INFORMATION ONLY. AF(200AF) (AFTER A NUMBER) = FUSE SIZE IN AMPS REFER TO FIXTURE DESIGNATIONS & LIGHTING FIXTURE RECEPTACLE WITH USB PORT SCHEDULE FOR LAMP TYPE & OTHER FIXTURE SPECIFICS. AFF ABOVE FINISHED FLOOR USB O SURFACE CEILING MOUNTED DOWNLIGHT AL ALUMINUM I� DUPLEX GFCI RECEPTACLE O RECESSED DOWNLIGHT (ROUND) ATS AUTOMATIC TRANSFER SWITCH DOUBLE DUPLEX GFCI RECEPTACLE BKR BREAKER 00 PENDANT MOUNTED FiXTURE OR CHANDELIER C CONDUIT Q DOUBLE DUPLEX RECEPTACLE MOUNTED IN CEILING SURFACE MOUNTED LINEAR FIXTURE CKT CIRCUIT DUPLEX RECEPTACLE MOUNTED +4"O.C. ABOVE COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) ® RECESSED LINEAR FIXTURE CL CENTERLINE DOUBLE DUPLEX RECEPTACLE MOUNTED +4"O.C. ABOVE ® PENDANT MOUNTED LINEAR FIXTURE CLG CEILING COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) WALL MOUNTED LINEAR FIXTURE C.Q. CONDUIT ONLY CU COPPER 1� DUPLEX GFCI RECEPTACLE MOUNTED +4*0.C. ABOVE LINEAR UNDERCOUNTER FIXTURE COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) -o COVE LIGHT (LENGTH AS SHOWN ON PLAN, DIA DIAMETER k® DOUBLE DUPLEX GFCI RECEPTACLE MOUNTED +4"O.C. ABOVE 0 TRANSFORMER(S) SHOWN AS REQUIRED) DISC DISCONNECT COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) DISP DISPOSER RECESSED WALLWASHER DF DRINKING FOUNTAIN SWITCHED (SPLIT) DUPLEX RECEPTACLE ® LINEAR EMERGENCY EGRESS FIXTURE - SPLIT BETWEEN DW DISHWASHER DOUBLE DUPLEX RECEPTACLE WITH 1/2 SWITCHED 2 R3 NORMAL AND EMERGENCY EGRESS WITH UL924 RELAY. HE1-5 DUAL CIRCUITS SHOWN ON PLANS. ECB ENCLOSED CIRCUIT BREAKER 10 GFCI RECEPTACLE WITH WEATHERPROOF WHILE -IN -USE COVER (E) EXISTING (USED AS SYMBOL DESIGNATION) WP Q RECESSED EMERGENCY EGRESS DOWNLIGHT EMT ELECTRICAL METALLIC TUBING 1-@ SINGLE SPECIAL PURPOSE RECEPTACLE EXTG EXISTING (USED AS ABBREVIATION IN TEXT) © JUNCTION BOX WITH BLANK COVER 33 PENDANT SURFACE EMERGENCY EGRESS DOWNLIGHT FLR FLOOR M1 UNIVERSAL/CEILING MOUNTED EXIT SIGN FAAP FIRE ALARM ANNUNCIATOR PANEL TELE/COMMUNICATIONS SYSTEM DEVICES WALL MOUNTED EXiT SIGN FRCP FIRE ALARM CONTROL PANEL TELEPHONE ® ® DIRECTIONAL EXIT SIGN (ARROWS INDICATE ONE OR TWO SIDES FSD FIRE SMOKE DAMPER W WALL MOUNTED TELEPHONE (VERIFY MOUNTING HEIGHT) AND DIRECTION INDICATED) FLIT FUTURE ® SINGLE GANG TELEPHONE/DATA OPENING FUTURE FURNITURE MOUNTED FIXTURE BY OWNER GEN GENERATOR TTB I TELEPHONE TERMINAL BOARD - 3/4" FIRE RESISTANT CONTROLS GFCI GROUND FAULT CIRCUIT INTERRUPTER PLYWOOD, 8' HIGH x LENGTH SHOWN ON PLAN GND GROUND QTV TELEVISION S DIMMER SWITCH HTR HEATER S VACANCY SENSOR LIGHT SWITCH HWT HOT WATER TANK SERVICE GEAR - AS SHOWN ON PLANS SP LIGHT SWITCH WITH PILOT LIGHT HOA HAND -OFF -AUTO CIRCUIT BREAKER PANELBOARD SK KEYED SWITCH kCMIL THOUSANDS OF CIRCULAR MILS S LV = LOW VOLTAGE, b = AREA TO BE CONTROLLED, KVA 1000 VOLT AMPERES LOAD CENTER R# = RELAY IN LIGHTING CONTROL PANEL G LIGHTING CONTROL PANEL S# = SENSOR ZONE KW 1000 WATTS LCP LIGHTING CONTROL PANEL o TERMINAL CABINET � CEILING MOUNTED VACANCY SENSOR LT LIGHT ® AS RONOPLANS OR CONTROL CENTER. SIZE Q SHOWN CEILING MOUNTED OCCUPANCY SENSOR LTS(LTG) LIGHTS (LIGHTING) FTI DRY TYPE TRANSFORMER (SEE NOTES & RISER ® PHOTOCELL LIGHT SENSOR LV LOW VOLTAGE DIAGRAM FOR SIZE) Q CEILING MOUNTED COMBINATION VACANCY MCB MAIN CIRCUIT BREAKER SENSOR/PHOTOCELL SENSOR MECH MECHANICAL CONDUITS AND CIRCUITING MLO MAIN LUGS ONLY NOTES AND MISCELLANEOUS SYMBOLS NIC NOT IN CONTRACT WIRING LOCATED IN CEILING OR WALL WIRING CONCEALED UNDER FLOOR OR UNDERGROUND "FLAGNOTE li:�> - IDENTIFIES A SPECIFIC ITEM ON A DRAWING. OC ON CENTER V✓ COORESPONDS TO A SCHEDULE IN THE ELECTRICAL SET THAT OH OVERHEAD -�- CONDUIT HOME -RUN EXPLAINS DETAILS OR FEATURES OF THAT ITEM. " "' /' /'' I'" SLASHES ACROSS CONDUIT INDICATE NUMBER OF WIRES OS OCCUPANCY SENSOR WITHIN - SHORT = HOT, LONG = NEUTRAL FF-3 MECHANICAL FLAG - DEFINES MECHANICAL EQUIPMENT AND PC PHOTOCELL COORESPONDS TO DESIGNATIONS IN MECHANICAL PLANS AND PNL PANELBOARD -s- ISOLATED GROUND WIRE SCHEDULES. COORESPONDS MECHANICAL CONNECTION SCHEDULE -i+ GROUND WIRE IN THE ELECTRICAL SET. REC RECEPTACLE(S) --� CONDUIT TURNS AND CHANGES ELEVATION AT THIS POINT <200> EQUIPMENTEQUIPMENT IPMENT REF REFRIGERATOR -� CONDUIT STUB -UP ONA PLAN AND COORESPONDS TO DESIGNATIONS IONSGIN (R) RELOCATED EXISTING �- CONDUIT BREAK EQUIPMENT SCHEDULE IN THE ELECTRICAL SET. RQMTS REQUIREMENTS i CONDUIT CONTINUES ELSEWHERE (NOTED ON PLAN) REVISION CLOUD AND FLAG - CLOUD SURROUNDS INFORMATION SQ SQUARE THAT HAS BEEN REVISED. FLAG IDENTIFIES THE REVISION IN SW SWITCH 1 WHICH THE CHANGES WERE MADE. EQUIPMENT CONNECTIONS & CONTROLS Teo TO BE DETERMINED ITDETAIL NUMBER - APPEARS IN FRONT OF A TITLE ON DRAWINGS. TTB TELEPHONE TERMINAL BOARD (9 EQUIPMENT CONNECTION TYP TYPICAL WALL MOUNTED EQUIPMENT CONNECTION /'3-'N IDENTIFICATION SYMBOL - CROSS REFERENCES INFORMATION IN E1.1 ONE AREA WITH A DETAIL (TOP #) AND SHEET (BOTTOM #) IN UC UNDER COUNTER MOTOR CONNECTION ANOTHER IN THE ELECTRICAL SET. UG UNDERGROUND g FAN CONNECTION NOTE: ALL FIXTURES AND EQUIPMENT SHOWN ON PLANS IN STANDARD UL UNDERWRITER'S LABORATORY DI DISCONNECT SWITCH (HEAVY) LINE WEIGHT ARE NEW OR RELOCATED WORK. FIXTURES AND U.O.N. UNLESS OTHERWISE NOTED OF I FUSED DISCONNECT SWITCH EQUIPMENT SHOWN IN LIGHT LINE WEIGHT WITH (E) NEXT TO THEM UT1L UTILITY INDICATE EXISTING TO REMAIN, SYMBOLS SHOWN AS DASHED INDICATE ® MAGNETIC MOTOR STARTER ITEMS TO BE REMOVED OR DEMOLISHED. THIS APPLIES UNLESS NOTED VA VOLT AMPERES COMBINATION STARTER AND DISCONNECT OTHERWISE ON PLANS. VFD VARIABLE FREQUENCY DRIVE ENCLOSED CIRCUIT BREAKER VS VACANCY SENSOR ••• HAND/OFF/AUTO SWITCH W WATTS •• START -STOP PUSHBUTTON SWITCH WAP WIRELESS ACCESS POINT WC WATER COOLER © PUSHBUTTON SWITCH W/D WASHER/DRYER S0 MOTOR RATED SWITCH W/o WITHOUT WP WEATHERPROOF XFMR TRANSFORMER FR �`tivl 13EtsUi t.:,D ,ZAechanical ❑ Electrical Plumbing Gas Piping Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any a e or rdinance. Receipt of approved F y i ' ns is acknowledged: i 9 By*, Date: City of Tulmild BUILDING DIVISION ad MIMI I ME Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 PERMIT SET 8-14-15 COMPLANC;L NFPA 70 - NEG J City of Tukwila BUILDING DIVISION Project Title: Tenant Improvem BECU TUKWILA LEGEND, N1 .AND SCHED REVISIONS NO es shall be made to the scope Of work Without prior approval of Tukvrriia Building Division. NOTIM: RevWorts drill require a nevv plan submittal and may in:;; de add°;ional plan reliew fees. --1 DRA►WI NG I N DEX EO.1 TITLE SHEET, LEGEND AND GENERAL NOTES EO.2 RISER DIAGRAM EO.3 1ST FLR PANEL SCHEDULES EO.4 2ND FLR PANEL SCHEDULES EO.5 3RD FLR PANEL SCHEDULES EO.6 4TH FLR PANEL SCHEDULES EO.7 5TH FLR PANEL SCHEDULES EO.8 6TH FLR PANEL SCHEDULES E1.1 1ST FLOOR POWER AND COMMUNITCATIONS PLAN E1.2 2ND FLOOR POWER AND COMMUNITCATIONS PLAN E1.3 3RD FLOOR POWER AND COMMUNMCATIONS PLAN E1.4 4TH FLOOR POWER AND COMMUNITCATIONS PLAN E1.5 5TH FLOOR POWER AND COMMUNITCATIONS PLAN E1.6 6TH FLOOR POWER AND COMMUNITCATIONS PLAN E2.1 1ST FLOOR LIGHTING PLAN E2.2 2ND FLOOR LIGHTING PLAN E2.3 3RD FLOOR.LIGHTING PLAN E2.4 4TH FLOOR LIGH'LN E2.5 5TH FLOOR LIGHTING'PLAN E2.6 6TH FLOOR ,LIGHTING'PLAN i EL2.1 1ST FLOOR EMERGENCY LIGHTING CALCULATIONS PLAN EL2.2 2nd FLOOR EMERGENCY LIGHTING CALCULATIONS PLAN EL2.3 3rd FLOOR EMERGENCY LIGHTING CALCULATIONS PLAN EL2.4 4th FLOOR EMER9ENCY LIGHTING CALCULATIONS PLAN EL2.5 5th FLOOR EMERGENCY LIGHTING CALCULATIONS PLAN EL2.6 6th FLOOR EMERGENCY LIGHTING CALCULATIONS PLAN RECEi+lED CITY OF TUKWILA AUG 12 2015 PERMIT CENTER 200 EXISTING FEEDER SIZE IN AMPS SOLID SHADING IN HEAVY LINES INDICATES NEW WORK IN THIS CONTRACT. ' PARTIAL SHADING IN LIGHT LINES INDICATES EXISTING EQUIPMENT THAT HAS BEEN MODIFIED IN THIS CONTRACT. N--Fi� AVAll AGE C reX XX T n 100CAIT iw AkA13Q% �ni..rnnv �_/ r v — �,.Jv mva, vv �rov��i. v, .w, ern � . ••• AUG 12 2015 PERMIT CENTER TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 c11 e 1. t�cta ;ar t n. END CASE r^f !f! EX ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 REVIEWED FOR COMPLIANCE WIIITF NFPA 70 - NEC SEP 0 4 2015 City of Tukwila BUILDING DIVISION Project Title: Tenant Improvement for: BECU TUKWI1-4TA 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: RISER DIAGRAM Designed By: RB Drawn By: MB Project No: 15110 Date: 08/05/2015 EXISTING RISER DIAGRAM NOT TO SCALE Sheet Number: PANEL: LE1 PROJECT NA ME BECU TUKVM LA PROJECT #. 15110 LOCATION: FLOOR 1 FED FROM 15 KVA XFMR TE1 NOTE CKT NO. CIRCUITNAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 0 AMP P R H I M L K O 1 TOTAL 1 1 SPARE A 20 1 PANEL AMPS : 80 2 3 LTS-OPEN OFFICEAND CORRIDORS-2ND B 20 1 0.5 0.5 FEEDER AMPS : 80 2 5 LTS-OPEN OFFICEAND OORRIDORS-3RD C 20 1 0.5 0.5 L - L VOLTS : 208 2 7 LTS-OPEN OFFICEAND CORRIDORS-411H A 20 1 0.5 0.5 L - N VOLTS : 120 2 9 LTS-OPEN OFFICEAND CORRIDORS-5TH B 20 1 0.5 0.5 PHASE: 3 2 11 LTS-OPEN OFFICEAND CORRIDORS-6TH C 20 1 0.5 0.5 WIRE : 4 13 SPARE A 20 1 15 SPA RE - - B 20 1 17 SPARE C 20 1 19 21 SPARE SPARE _ - -- - - A 20 ..._ __.. B 20 ._1 1 _ .._ .. . _-- _._ - ......-- ... M.L.O. MA IN CB FLUSH X 23 SPARE C 20 1 1 SPARE A 20 1 SURFACE X 27 SPARE B 20 1 ISO GND 125 29 SPARE C 20 1 FEED-lHRU 31 SPARE A 20 1 --3�3- SPARE B 20 1 35 SPARE C 20 1 37 SPARE A 20 1 LOADSUMMARY 39 SPARE B 20 1 ( TOTAL, ALL SECTIONS ) 41 SPARE C 20 1 REC KVA : 2 SPARE A 20 1 1 4 SPARE B 20 1 HEAT KVA : 6 SPARE C 20 1 1 1 1 1 MOTOR KVA : 8 SPARE A 20 1 LIGHTING KVA : 2.5 10 SPARE B 20 1 1 KITCHEN KVA : 12 SPARE C 20 1 OTHER KVA : 14 SPARE A 20 1 16 SPARE B 20 1 _ PHASEA KVA : 0.5 18 SPARE C 20 1 _ AMPS : 4.2 2 SPARE A 20 1 PHASE BKVA : 1.0 22 SPARE B 20 1 AMPS : 8.3 24 SPARE C 20 1 PHASE CKVA : 1.0 26 28 SPARE SPA RE A 20 B 20 1 1 AMPS : 8.3 30 SPA RE C 20 1 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE B 20 1 KVA : 2.5 36 SPARE --C -20 1 AMPS : 6.9 38 SPARE A 20 1 DEMAND LOAD 40 SPARE B 20 1 KVA : 3.1 42 SPARE C 20 1 AMPS : 8.7 NOT ESJREMARKS: I. EXISTINGCIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES- TO 10KVA 10010 = REVIANING OVER 10KVA 500/0 = H HEATING 100% = M MOTORS 100% = LM LARGESTMOTOR 125% = L LIGHTING 125% = 3.1 K KITCHEN 65% = O OTHER 100% _ PANEL: H1A (SECTION 1) PROJECT NA IVE BECU TUKVA LA PROJECT #: 15110 LOCATION: FLOOR 1 FED FROM 2ND FLR 400A DISCONNECT NOTE CKr1 NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 0 AM P R H M L K O TOTAL 2 1 LTS- ENCLOSED OFFICEAND SUPPORT A 20 1 2.6 2.6 PANEL AMPS : 400 2 3 LTS-BNCLOSEDOFFICE AND SUPPORT B 20 1 1.2 1.2 FEEDER AMPS : 400 5 SPARE C 20 1 L- LVOLTS: 480 7 SPARE A 20 1 L- NVOLTS: 277 R LASE : 3 WRE : 4 --" 8 11 13 -- SPARE - SPARE..-... - - -- _.....-- ------ ---- SUBFEEDTO GARAGEPANR HG - - B -- --. ,---- C - A 50 .... - --.. - - 3 15 --- B -- - 17 --- C -- - M.L.O. 3 19 FTPU 143,144,145 - T A 30 1 5.0 2.1 7.1 MAIN CB 2 21 FPTU 113 B 30 1 3.5 0.7 4.2 FLUSH 2 23 FPTU 140 C 30 1 4.0 0.7 4.7 SURFACE X 2 25 FPTU107,114,134 A 50 3 6.5 1.1 7.6 ISO GND B - - 6.5 1.1 7.6 FEED•THRU X C -- - 6.5 1.1 7.6 2 31 FPTU 1101111,112 A 50 3 6.5 1.0 7.5 B -- - 6.5 1.0 7.5 - 2 35 C - - 6.5 1.0 1 7.5 1 37 FTPU115,116,117 A 50 3 6.5 0.7 7.2 LOADSUMMARY 1 39, --- B -- 7.0 1.5 8.5 (TOTAL, ALL SECTIONS) 1 41 --- C -- - 7.0 1.1 8.1 REC KVA : 2 LTS•OPEN OFFICEAN D CORRIDORS A 20.1. 1 4.1 4.1 1 4 LIGHTS - PARKING B 20 11 1 3.7 3.7 HEAT KVA : 155.1 1 6 LIGHTS- PARKING C 20 1 3.7 3.7 MOTOR KVA : 26.7 1 8 LIGHTS - PARKING A 20 1 3.7 3.7 LIGHTING KVA : 30.0 1 10 LIGHTS - BLDG EXTERIOR B 20 1 2.3 2.3 KITCHEN KVA : 1 12 LIGHTS- BLDG EXTERIOR C 20 1 2.3 2.3 OTHER KVA : 3 14 FPTU 108 A 20 1 3.5 0.7 1 4.2 3 16 FPTU 135 B 20 1 3.0 0.7 3.7 PHASEA KVA : 72.6 2 18 FPTU 101 C 30 1 4.0 0.7 4.7 AMPS : 262.1 2 20 FPTU 119 A 30 1 4.0 0.7 4.7 R-ASE B KVA : 68.7 2 22 FPTU 102 B 30 1 4.0 0.7 4.7 AMPS : 248.0 2 24 FPTU 104 C 30 1 3.5 0.7 4.2 PFIASEC KVA : 70.5 2 26 FPTU 118 A 30 131 4.0 1.0 5.0 AMPS : 254.5 2 2 28 32 --- .... . ,. SPARE B -- -- A 50 - .- .--..._....--- .--- 3 4.0 4.0 ---- -- ---- ---- .----- --- -- -- ---. --- --- 4.0 ., 4.0 ---- CONNEr,TEDILOAD 2 34 B -- KVA : 211.8 C - - AMPS : 254.8 2 38 FPTU 138,139 A 50 3 6.0 0.7 6.7 ' DEMAND LOAD 2 40 --- B -- 6.0 6.0 ' KVA : 219.8 C -- - 6.0 1.5 7.5 AMPS : 264.4 NOTES(REMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKERAS INDICATED DEMAND / DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO IOKVA 100% = REMAINING OVER 10KVA 50% = H HEATING 100% = 155.1 M MOTORS 100% = 24.6 LM LA RGEST MOTOR 125% = 2.6 L LIGHTING 125% = 37.5 K KITCHEN 65% = O OTHER 100% = PANEL: HE (LIFE SAFETY) PROJECT NAME BECU TUFNULA PROJECT#: 15110 LOCATION: FLOOR 1 FED FROM: 600A ATS #2 NOTE CKT NO. CIRCUITNAME CB SIZE LOAD (KVA) PANEL DESCRIPTION 0 AMPI PI R H M I L K O TOTAL 1 XFMRTE1 A 80 3 1 0.5 0.5 PANEL AMPS : 800 3 - - - B - - - i -� 1.0 1.0 FEEDER AMPS : 600 5 - - C -- - - 1.0 1.0 L - L VOLTS : 480 7 PANEL HE1 A 100 3 , 5.5 5.5 L - N VOLTS : 277 9 --- B -- - ! 6.5 6.5 R-ASE: 3 11 - i C - - 15.3 5.3 WIRE : 4 13 15 PANEL HRE --- - A 200 B- 3 ( _ 17 --- C -- - 19 21 FREIGHT ELEVATOR SHUNT TRIP - --- -- ... A 80 --- ... g -- 3 - _ ..-..-__-.._- - 11.0 ...-. 11.0 _- 11.0 11.0 M.L.O. MAN CB FLUSH 23 - - - C - - - 11.0 11.0 25 SPARE A 20 1 SURFACE X 27 SPARE B 20 1 �F. ISO GND 29 SPARE C 20 1 FEED•THRU 31 SPARE - A 20 1 33 SPARE - B 20 1 -1 : 35 SPARE - C 20 1 37 SPARE - A 20 1 LOADSUMMARY 39 SPARE B 20 1 1; ( TOTAL, ALL. SECTIONS) 41 SPARE C 20 1 �-� REC KVA : 2 XFNR TE2 A 80 3 4 --- B -- HEAT KVA : 6 - - - C - - MOTOR KVA : 33.0 8 SPARE __ SPARE A 20 _._ B 20 1 1 ----- -- LIGHTING KVA : 19.8 KITCHEN KVA : 10 --- 12 SPARE C 20 1 OTHER KVA : 14 SPARE A 20 1 ~: __ 16 SPARE -- B 20 1 �( PHASEA KVA : 17.0 18 SPARE -. C 20 1 ^I AMPS : 61.4 20 AG1 A 40 3 €-_ PHASE B KVA : 18.5 22 --- B -- - i AMPS : 66.8 24 - - C - - f PHASE C KVA : 17.3 26 28 SPARE SPARE A 20 B 20 1 1 AMPS : 62.5 30 SPARE C 20 1 ) 32 SPARE A 20 1 a CONNECTEDLOAD 34 SPARE B 20 1 KVA : 52.8 L 36 SPARE C 20 1 1 1 AMPS : 63.5 38 SPARE A 20 1 DEMAND LOAD - 4D SPARE B 20 1 KVA : 60.5 42 SPARE C 20 1 ( AMPS : 72.8 NOTESIREMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEWCIRCUIT BREAKER AS INDICATED DEMAND! DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES- TO 10KVA 100% = RENIAININGOVER 10KVA 50% = H HEATING 100% = M MOTORS 100% = 22.0 LM LARGEST MOTOR 125% = 13.8 L LIGHTING 125% = 24.8 K KITCHEN 65% = O OTHER 100% _ PANEL: H1B (SECTION 2) PROJECT MICE BECU TUKWILA FROJECT#: 15110 LOCIATION: FLOOR i FED FROM FANEL H1A NOTE CKT CIRCUIT NAME CB SIZE LOAD (KVA) 0 ANOIP R I H M I L K I 0 TOTA 4 140. PANEL DESCRIPr10N 1 1 LTS - TELLER LJUE A 20 1 ? 1.0 1.0 PANEL A WS : 400 1 3 .....................................I................ LT5 -TELLER LINE B 20 i 1 ........ ................d.......... ....... ; 1,0 1.0 FEEDERAWS : 400 ..........................................•........•...:••.....:..:•......' 5 ..................................................... LTS - 5W PBRIfvErER 'E tTERr'iR .........•.•.•.P:..............•..0...........•.I........•.....o..............:........•................... C 20 ;1 ; I. 1.0 : .i 1.0 L- L V OLTS : 480 1...... I....... .........................................................................-....................................................................... 7 LTS - futA1L Rfut A 20 .I ;.... ;..............e.................. a ........ ....... ! 1.0 I 1.0 L- N VOLTS : 277 ...................................... 1 9 ..:...................................................................................._....:..................,....•.........;......:.......o..............;..............,.............................. LTS - CATW'ALK B 20 ;1 0,4 € i..............:............................:..............i....... 0:4 PHASE: 3 .............:................:..............I................ 1 11 _...............................................................................:.................. LTS - CORROCR C 20 ;1 ........... ; 1.0 . . 1:0 ............. tNIRE : 4 ..................•.••.•.............. 13 .............................................................................................:..................e...........................a..............,..............o............. LTS-GOREAREA p ; i I 1.0 I I............................... ................. 1.0 .1 1 �a FPrU 141.145 .:...::I.. B 3'0 11 ..............;..............I..............,.............. ': 3.5 ; 1.4 ; € •. 4.8 .....i...... 17 ....................................................................................,..................a............................,..............;..............a.......... SPACE C 20 11 s... ........... M.L.O. }( ............................................................................................................................................................... 19 SPACE A 20 >1 ... •.... ...... ...I.... ....... ?........... ....... ... i d........................... tu1� ItNCB .................................................................................................................................................:................................;..............:........... 21 SFkaCE B 20 11 .... ........... ; FLUSH ....-.........................................................................................................................................:..................:............I.d.......................... 23 SFARE C 20 :1 ........ ...... ; :.......... .......... SURFACE X .....................................................................................................................................-.........,................................:......................... 25 St3ACE A 20 ':,1 .... I .. ... ISO GND ...............................................................................................................................................I..•...........I................>........ 27 SPATE B 20 11 ....... ....... ....... d... .......... FEED-THRU' .................................................................................................................................................:..................o..............I.............•:........... 25 SPACE C 24l ;1 ... ....... ....... I [.............. a..............;............................... ........... ............... .................................................................................................................. 31 SPARE ....1.... A 20 (1 ..............:...............8.............. .................. 33 :..:.........................................................................................-.....................e..................e............_i..............b..............i..............p........ SFk`RE B :1 1. ........... ................. 35 .....•.............................................................................................................. SPARE . C 20 .1 ;.... I........................... ................................I.... ....... I € .......... 1 ............... 37 .............................. .............................. ......... AIRCURTAIPIQ WAREHOUSE . ......................:.............................:.......................................................... A 20 ,1 ; I 1.0 ; 1.0 LOADSUMMARY .............. 1 .......... 39 ......................................................................................................... ROLL UPDDOR .... ...........:.... @ 20 i2 ............................4.............. ..............u.............. .............. ; 0.$ i o...................... ................. 0.$ [T6TH: f€Eid T045) ...................2...................................................................................................... 1 41 :......:....................................................................... .........•.....;..................;............................ G - I s............................ I 0:8 ' : ....... . 0.8 REC WA : 1 2 SPARE .............. A 20 :1 I ; 1 4 SPARE !1 8 HEAT KVA : 31.1 ...............................................................I................. 1 8 SPARE .:20 .....:..................:..............o.............................o......................... C 20 :1 ; ............ ....I..... ...... MOTOR KVA : 8.2 ..................... 8 ......:.:.....:........................................................................................................+.................. SF"r> PE 2a .1 o..............;..............41.......... ....... ....... ?................ a............ o. ...........i. UGHTItNG KVA : 5.4 ...... 1 10 ................................................................................................... SPARE .:........................... B 20 i 1 ................. ...I.................. ? I ..................... KrTCHE14 KVA : .................................................................................................................................................N...............d.............:..............:..............:..............:.............................. 1 12 SFPtRE G ':1 ; ;................ OTHER WA : ......................- 1 14 ........................................................................................................................:..................;..............: WATER NEATER- FIRE PUMP ROOM A 60 13 .................. ........... ...... ........................ I 5.0 ; a... 5.0 ................. 1 .........:..:....:.........................:..........................:.........................................................:..................:...........................a..............¢........... 15 --- B -- I ; 5.0 I ......... PHASEA KVA : 12.2 ...... ...........................................................................................................................................................:..............,..............I.............•;........... 1 1$ - - - G - - ': - .......5.0.. ;.... ......5.0 ; 5.0 ': ; ; 5.0 A fv1PS, : 44.0 ........ ......... 20 .......................................................................................................................:.J FPIU 105 A ?0 ' ..............a..........................................................,............. ; 3.2 •...a... . ................ 3,2 PHASEB WA : 15.3 .............. 2 .......... 22 ............................................................................................................. --- ........... V... B -- .............. :.............:............................. ....... ;.... I 3.2 : 3,2 AMPS : 55.2 .................................................................................................................................................:..................:..............;..............,..............s.............. 2 24 --- C -- :... ....... ':, 3.2 i 1.5 ; .... 4.7 FFIASEGKVA : 15.2 ................................................................................................................................................'................;..............:.........I 2 25 SFYiRE A ?J 3 ....;........... ....... ....I .. ...p... ........ ...... ........... ... AMPS: 55.5 .................................................................................................................................................a..................;........................ 2 2$ --- B -- ;- ........ ....... ....... I ........... ................................................................................................................................................:................................:.............. I.... i ................ :........... ...I... .......... 2 30 - - C -- - .................................................................................................................................................:.......•..••••....;.............. 32 SF,GE A ; .............a..............a..............:.......... I CC1JhIECTED LOAD -2 .......................................................................................................................................:............... .I.............�........... ...... :. ..:.... 2 34 SFr. RE B 201 ;1 I s : KVA 43.7 ...... 2 ...............................................................................................•...•............... FPrU 135 .,..................:..............i..............:.............................;... C 20 ;1 .................... 3.0 10.7 3,7 AI&S : 52.5 ................................................................................................................................................:.................................:........... 2 SPARE A M ; 3 ........ ........ ....... .......... DE AND LOAD ............ 2 40 ....................................................................................................................a..................:...........................a..............1..............:. . - 8 - - : ............................. F - KVA : 45. r ...........38 .................................................................................................................................:..................:..............a........... 42 - - - G - - - ..........a........... ....... ..........i AMPS: 54.9 NOT E19REMARKS : DEMAND / DIVERSITY FACTORS 1. EKISTIf4GCtRCUfr LOAD DESCRPTION DEMAND 2. EKISTIh1G CIRCUrr MODIFIED BY THIS PROJECT R RECEPTACLES- TO 10K'JA 100% _ 3. PROVIDENEW CIRCUIT BREAKERAS INDICATED RE* ININGOVER 10KVA 50% = H HEATING 100% = 31.1 IA 191DTORS 100% = 4.7 LM LARGESTMOTOR 125% = 1.9 L LIGHTING 125% = 8.0 K KITCHEN 65% = O OTHER 100% = PANEL: HE1 (LIFE SAFETY) PROJECTNAME BECU TUKWILA PROJECT#: 15110 LOCATION: FLOOR 1 FED FROM PANEL HE NOTE CKT NO. CIRCUIT NAM E CB SIZE I LOAD(KVA) PANEL DESCRIPTION 0 AMP P R H M L K 0 TOTAL 2 1 LTS-OPEN OFFICEAND CORRIDORS -1ST FLR A 20 1 2.2 2.2 PANEL AMPS : 100 2 3 LTS-OPEN OFFICEAND CORRIDORS-2ND B 20 1 3.2 3.2 FEEDER AMPS : 100 2 5 LTS-OPEN OFFICEAND CORRIDORS-3RD C 20 1 3.3 3.3 L - L VOLTS : 480 2 7 LTS-OPEN OFFICEAND CORRIDORS-4TH A 20 1 3.3 3.3 L - N VOLTS : 277 2 9 LTS•OPEN OFACEAND CORRIDORS-5TH B 20 1 1 3.3 3.3 PHASE : 3 2 11 LTS-OPEN OFFICEAND CORRIDORS-6TH C 20 1 1 2.0 2.0 WIRE : 4 13 SPARE A 20 1 15 SPARE B 20 1 17 SPARE C 20 1 I 11 19 21B SPARE -----....----- .,.-....._ . SPARE A 20 20 1 ... 1 ---- ------ ------. M.L.O. MAN CB X 23 ISPARE C 20 1 FLUSH 25 SPARE A 20 1 SURFACE X 27 SPARE B 20 1 ISO GND 29 SPARE C 20 1 FEED-THRU 31 SPARE A 20 1 33 SPARE T B 20 1 35 SPARE C 20 1 37 SPARE A 20 1 LOADSUMMARY 39 SPARE - B 20 1 ( TOTAL, ALL SECTIONS ) 41 ISPARE C 20 1 REC KVA : 2 SPARE A 20 1 4 SPARE B 20 1 HEAT KVA : 6 SPARE C 20 1 MOTOR KVA : 8 SPARE SPARE A 20 B 20 1 LIGHTING KVA : 17.3 KITCHEN KVA : 10 11 12 SPARE C 20 1 - OTHER KVA : 14 SPARE A 20 1 16 SPARE B 20 1 1 1 R-IASEA KVA : 5.5 18 - SPARE C 20 1 AMPS : 19.9 20 SPARE A 20 1 PHASEBKVA : 6.5 22 -- SPARE B 20 1 AMPS : 23.5 24 SPARE C 20 1 1PHASECKVA : 5.3 . .., 26 28 SPARE -. .....,--- --- ....., . - SPARE A 20 - ..., ............ 20 1 . -.-- 1 _...... ..... AMPS : 19.1 30 SPARE C 20 1 32 SPARE A 20 1 CONNECTEDLOAD 34 SPARE B 20 1 KVA : 17.3 36 SPARE C 20 1 - AMPS : 20.8 38 SPARE -- - A 20 1 DEMAND LOAD 40 SPARE B 20 1 KVA : 21.6 42 SPARE - C 20 1 AMPS : 26.0 NOTES/REMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND / DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO IOKVA 100% = REVAINING OVER 10KVA 50% = H HEATING 100% = M MOTORS 1013% = LM LARGESTMOTOR 125% = L LIGHTING 125% = 21.6 K KITCHEN 65% = O OTHER 100% _ PANEL: LC6 (SECTION 2) PROJECT NAME BECU TUKWILA PROJ EC #: 15110 LOCATION: FLOOR 1 FED FROM PANEL LC8 NOTE CKT NO. CIRCUITNAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 0 Ti7q P R H M L K I O TOTAL 1 3 SPARE SPARE - ��-----_-...-._ A 20 B 20 1 1 -- PANEL AMPS : 225 FEEDERAMPS : 225 5 SPARE C 20 1 L- L VOLTS : 208 7 SPARE A 20 1 L - N VOLTS : 120 9 - SPARE B 20 1 PHASE : 3 11 SPARE C 20 1 WRE : 4 13 SPARE A 20 1 15 SPARE B 2011 17 SPARE C 20 1 M.L.O. X 19 SPARE - A 20 1 1 MAIN CB 21 SPARE B 20 1 1 FLUSH 23 SPARE C 20 1 SURFACE X 25 SPARE - A 20 1 ISO GND 27 I SPARE B 20 1 FEED-THRU X 29 SPARE C 20 1 31 SPARE A 20 1 33 SPARE - B 20 1 35 SPARE C 20 1 37 SPARE A 20 1 LOADSUMMARY 39 ISPARE B 20 Ill I I (TOTAL, ALL SECTIONS) 41 SPARE C 20 11 1 REC KVA : 2 SPARE A 20 11 I 4 SPARE B 20 1 HEAT KVA : 6 SPARE C 20 1 MOTOR INA : 8 SPARE A 20 1 LIGHTING KVA : 10 ISPARE B 20 1 1 KITCHEN KVA : OTHER KVA : 12 SPARE C 20 1 14 SPARE A 20111 16 SPARE B 20111 PHASEA KVA : 18 SPARE C 20 1 I AMPS : 20 SPARE A 20 1 PHASE B KVA : 22 I SPARE B 20 1 AMPS : 24 SPARE C 20 1 PHA SEC INA : 26 SPARE A 20 1 AMPS : 28 SPARE B 20 1 30 SPARE C 20 11 _ 1 32 SPARE A 20 1 CONNECTED LOAD 34 I SPARE B 20 1 INA : 36 SPARE C 20 1 AMPS : 38 SPARE A 20 1 DEMAND LOAD 40 SPARE B 20 1 ::� ]INA 42 SPARE ICI 20 ----� 1 AMPS : NOTES(REMARKS : 1. 2. 3. DEMAND / DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES -TO1DKVA 100% = REMAINING OVER IOKVA 50% = H HEATING 100% = M MOTORS 100% = LM LARGESTMOTOR 125% = L LIGHTING 125% = K KITCHEN 65% = O OTHER 100% _ PANEL: L1 (SECTION 1) PROJECT NAME BECU TUKWLA PROJECT #. 15110 LOCATION: FLOOR 1 FED FROM: 225 KVA XFMR T2 NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 0 AMP P R I H M L K O TOTAL 2 2 1 ___ 3 RECS - COPY RM 136 _ __ RECS - COPY RM 137 -- - - ---...__...._.. A 20 _ B 20 1 0.6 ' ..1.. 0.6 - - ...---- . __ ._ .... _-_..__.. 0.6 0.6 PANEL AMPS : 400 FEEDER AMPS : 400 2 5 RECS - COPY RM 114 C 20 1 0.6 '1 0.6 L- L VOLTS : 208 2 7 RECS - COPY RM 114 AI 20 1 0.4 i 0. L - N VOLTS : 120 9 SPARE B 20 1 i PHASE: 3 11 SPARE C 20 1 WIRE : 4 2 13 RECS - EXAMINER ROOM A 20 1 0.7 0.7 15 SPARE B 20 1 17 SPARE C 20 1 ML.O. 19 SPARE A 20 1 MAIN CB X 21 SPARE B 20 1 I FLUSH 23 SPARE C 2D 1 SURFACE X 25 SPARE A 20 1 I - ISO GND 27 SPARE 8 20 1 -� FEED-THRU X 29 SPARE C 20 1 31 SPARE A 20 1 33 SPARE B 20 1 35 SPA RE C 20 1 1 1 37 SPARE A 20 1 ! LOADSUMMARY 39 SPARE B 20 1 i ( TOTAL, ALL SECTIONS ) 41 SPARE Cl20 1 1 - REC KVA : 19.4 2 2 RECS - OPEN OFFICE 156 A 20 1 1 0.6 0.6 2 4 REFS - OPEN OFFICE 156 B 20 1 0.6 I 0.6 HEAT KVA : 2 6 RECS - OPEN OFF 156, STOR 157, OFF 158 C 20 1 0.7 I 0.7 MOTOR KVA : 1.4 2 8 VVORKSTATION - OPEN OFFICE 131- A 2D 1 0.7 1 0.7 LIGHTING KVA : 2 10 VVORKSTATION - OPEN OFFICE 132 B 20 1 0.7 1 0.7 KITCHEN KVA : 2 12 WORKSTAT10N - OPEN OFFICE 133 C 20 1 0.7 ; 0.7 OTHER KVA : 1.2 2 14 REFS- EXAMINER ROOM 170 A 20 1 0.8 i 0.8 2 16 RECS- EXAMINER ROOM 170 B 20 1 0.8 j 0.8 PHASEA KVA : 7.9 2 18 RECS - LG CCNF 159 C 20 1 0.7 1 0.7 AMPS: 65.8 2 20 COPY RM EXH FANS EF 101, EF 102 A 20 1 1 1.4 1.4 FHASE B KVA : 7.5 22 1 SPARE B 20 1 i AMPS: 62.5 24 SPARE C 20 1 i RiASEC KVA : 6.6 26 SPARE A 20 1 j AMPS: 55.0 28 SPARE B 20 11 30 SPARE C 20 1 32 SPARE A 20 1 CONNECTED LOAD 34 1 SPARE B 20 1 KVA : 22.0 AMPS: 61.1 36 SPARE C 20 1 I 38 SPARE A 20 1 1 DBVlANDLOAD 40 SPARE BI 20 1 1d- KVA : 17.7 42 SPARE Cl20 1 1 :' ��L A MPS : 49.0 NOTESMENIARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NBNCIRCUIT BREAKER AS INDICATED DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEVWND R RECEPTACLES- TO 10KVA 1000/0 = 10.0 REMAINING OVER 10KVA 50% = 4.7 H HEATING 1000/0 = M MOTORS 1000/0 = LM LARGEST MOTOR 125% = 1.8 L LIGHTING 125% = K KITCHEN 65% = O OTHER 100% = 1.2 PANEL: HGE PROJECT NAME BECU TUKWLA PROJECT #: 15110 LOCATION: FLOOR 1 FED FROM: 200A ATS $r3 NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 0 A P RI H M L K O TOTAL 2 1 75KVA XFMR TG1 A 20013 7.4 I 4.6 12.0 PANEL AMPS: 2DO 2 3 - - - B - - - 6.4 3.6 10.0 FEEDER AMPS : 200 2 5 --- C -- - 7.5 1 1.0 1.5 10.0 L- LVOLTS : 480 7 SPARE A 20 1 L- N VOLTS : 277 9 SPARE B 2D 11 PHASE: 3 11 - SPARE C 20 11 I VVIRE : 4 13 SPARE _ A 2011 15 SPARE B 20 1 17 SPARE C 20 1 I 19 21 SPARE SPARE A 20 11 B 20 i 1 I MA IN C M.L.O. B X 23 SPARE C 20 1 FLUSH 25 ISPARE Al20 11 j SURFACE X 27 SPARE B 20 11 j ISO GND 29 SPARE C 20 1 1 i FEED-THRU 31 SPARE A 20 j 1 i 33 SPARE B 2011 _ 35 SPARE C 2011 1 37 SPARE 011 _ LOADSUMMARY 39 SPARE 20 1 JB 1 (TOTAL, ALL SECTIONS ) 41 SPA RE 20111 I REC KVA : 21.3 2 SPARE A 20 1 i I 4 SPARE B 20 '1, 1 1 HEAT KVA : 6 SPARE C 20 1 MOTOR KVA 8 _ SPARE A 20 1 1 LIGHTING KVA : 10 SPARE B 20 ! 1 KITCHEN KVA : 9.2 12 SPARE A C 2011 1 OTHER KVA : 1.5 14 SPARE AV20 16 SPARE B PHASEA KVA : 12.0 18 SPARE C AMPS: 43.3 20 _ SPARE A PHASEBKVA : 10.0 22 SPARE B AMPS: 36.1 24 SPARE C 1 PHASEC KVA : 10.0 26 28. SPARE SPA1. RE 11 . 11_ _ A 20 11 B 20 1 - AMPS: 36.1 30 SPARE C 2011 ' 32 SPARE A 20 j 1 _ CONNECTED LOAD 34 SPARE B 20 1 _ KVA : 32.0 36 SPARE V Y C 2011 1 AMPS : 38.5 38 SPARE A 2011 DE]V1ANDLOAD 40 SPARE B 20 '.1 KVA : 23.1 42 SPARE C 20 1 i AMPS : 27.8 NOTESfREMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDENEWCIRCUIT BREAKERAS INDICATED DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 1000/0 = 10.0 REMIAINNG OVER 10KVA 50% = 5.7 H HEATNG 100% = M MOTORS 1000/0 = LM LARGEST MOTOR 125% = L LIGHTING 125% = K KITCHEN 65% = 6.0 O OTHER IOD% = 1.5 PANEL: LC8 (SECTION 1) PROJECT NAME BECU TUKVM LA PROJECT #: 15110 LOCATION: FLOOR 1 FED FROM: 225A FUSE NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 0 AM P R H M L K 0 TOTAL 2 1 WORKSTATION - OPEN OFFICE 131 A 20 1 1.2 1.2 PANEL AMPS : 225 2 3 WORKSTATION - OPEN OFFICE 132 B 20 1 1.2 1.2 FEEDER AMPS : 225 2 5 WORKSTATION - OPEN OFFICE 133 C 20 1 1.2 1.2 L - L VOLTS : 208 2 7 RECS- CASH RM 127 A 20 1 0.6 0.6 L - N VOLTS : 120 2 9 RECS- OFFICES 117,117,118,119 B 20 1 1 1.2 1.2 R-LASE: 3 2 11 RECS- OFFICES 120,121,122,123 C 20 1 1.2 1.2 WIRE : 4 1 13 EXIST VAULT CIRCUIT A 20 1 0.7 0.7- 2 15 RECS- OFFICES 112,113, SMCONF 174 B 20 1 1 0.2 0.6 0.8 2 1 17 WALL RECS- QUENG 150 C 20 11 0.6 0.6 M.L.O.2 2 19 21 RECS- OPEN OFFICE 156 _...-_-_ RECS- OPEN OFFICE 156, OFFICE 158 A 20 ... - - -- B 20 1 - 1 -- - - -- --- . - --- 0.9 1.2 0.9 1.2 MAN CB FLUSH X 2 23 RECS- LRG CONF 159 C 20 1 0.2 0.2 SURFACE X 2 25 REC- LG CONF 105 A 20 1 0.2 0.2 ISO GND 2 27 I REC- LG CONF 105 B 20 1 0.2 1 1 0.2 FEH}THRU X 29 SPARE C 20 1 31 SPARE A 20 1 33 SPARE B 20 1 35 SPARE C 20 1 37 PANEL LC14 A 100 3 1.4 5.7 _ 7.1 LOADSUMMARY 39 - - - B - - - 1.8 1 5.7 7.5 ( TOTAL, ALL SECTIONS) 41 --- C -- - 1.1 5.4 6.5 REC KVA : 6.5 2 2 RECS- OPEN OFFICE 124 A 20 1 1 0.9 0.9 2 4 RECS- OFFICES 108,209,131,132 B 20 Ill 1 1.2 1.2 HEAT KVA : 2 6 RECS- OFFICES 106,107,133 C 20 1 0.9 0.9 MOTOR KVA : S SPARE A 20 1 1 1 LIGHTING KVA : 2 10 RECS- SMCONF 134,135 B 20 1 0.4 1 0.4 1 KITCHEN KVA : 2 12 RECS- GREETING AREA 100 C 20 1 0.6 0.6 OTHER KVA: 35.2 2 14 KIOSK- QUBNG 150 A 20 1 0.3 0.3 2 16 KIOSK- QUBNG 150 B 20 1 0.3 0.3 PHASEA KVA : 13.3 2 18 KIOSK- QUBNG 150 C 20 1 0.3 0.3 AMPS : 110.8 2 20 RECS- TELLER LINE 153 A 20 1 1 0.6 0.6 PHASE B KVA : 15.4 2 22 RECS- TELLER LINE 153 B 20 1 I 1 0.6 0.6 AMPS : 128.3 2 24 RECS- TELLER LINE 153 C 20 1 0.6 0.6 PHASE C KVA : 13.0 2 2 26 28 RECS- TELLER LINE 153 RECS- TELLER LNE 153 A 20 B 20 1 1 _-- 0.6 ...... 0.6 0.6 ............. 0.6 AMPS : 108.3 2 30 RECS- VAULT 154,155 C 20 1 0.9 0.9 2 32 RECS- LG CONF 159 A 20 1 0.2 1 0.2 CONNECTED LOAD 2 34 RECS- LG CONF 159 B 20 1 0.2 0.2 KVA : 41.7 36 SPARE C 20 1 AMPS : 115.7 38 SPARE A 20 1 DBVIAND LOAD 40 SPARE B 20 1 KVA : 41.7 42 ISPARE C 20 1 AMPS : 115.7 NOTES/REMARKS : 1. EXISTINGCIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES- TO 1 OKVA 100% = 6.5 REVIAININGOVER 10KVA 50% = H HEATING 100% = M MOTORS 100% = LM LARGESTMOTOR 125% = L LIGHTING 125% = K KITCHEN 65% = O OTHER 100% = 35.2 PANEL: L1B (SECTION 2) PROJECT NAIVE BECU TUKWLA PROJECT#: 15110 LOCATION: FLOOR 1 FED FROM PANEL L1 NOTE CKT NO. CIRCUITNAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 01AMPIP1 R I H M L I K O 1 TOTAL 2 -- - 2 1 - ..._. 3 I REC - OPEN OFFICE 130, VESTIBULE 126 _ --- - --- -- -- -- ----------._- RECS - OFFICES 117,117,118,119 A 20 . -. _..--- B 20 1 0.7 -- --- 1 1.3 0.7 1.3 PANEL AMPS : 400 FEEDER AMPS : 400 L - L VOLTS : 208 2 5 RECS - OFFICES 120,121,122,123 C 20 1 1.3 1.3 2 7 RECS - HALL 125, COFFEE 115 A 20 1 0.4 0.4 L - N VOLTS : 120 2 9 RECS- OFFICES 112,113, CONF 111 B 20 1 0.7 0.7 PHASE: 3 2 11 RECS- CONF 111,174 C 20 1 0.6 0.6 WIRE : 4 13 SPARE A 20 1 15 SPARE B 20 1 17 SPARE C 20 1 M.L.O. X 19 SPARE A 20 1 MAIN CB 21 SPARE B 20 1 FLUSH 23 SPARE C 20 1 - SURFACE X 25 SPARE A 20 1 ISO GND 27 SPARE B 1 20 1 FEED•THRU X 29 SPARE C 20 1 _ 31 SPARE A 20 1 33 SPARE B 20 1 35 SPARE C 20 1 37 ,- SPARE A 20 1 LOAD SUMMARY 39 SPARE B 20 1 ( TOTAL, ALL SECTIONS ) 2 41 REC - COFFEE 115 C 20 1 0.2 0.2 REC KVA : 11.4 2 SPARE A 20 1 4 SPARE B 20 1 HEAT KVA : 6- SPARE C 20 1 _- MOTOR KVA : 8 SPARE A 20 1 LIGHTING KVA : 10 SPARE B 20 1 KITCHEN KVA : 12 SPARE C 20 1 OTHER KVA : 2 14 VWRKSTATIONS-OPEN OFFICE 124 A 20 1 0.6 0.6 2 16 RECS -OFFICE 108, 109, 131, 132 B 20 1 1.3 1.3 PHASEA KVA : 2.7 2 18 RECS - OFFICE 106,107,108,133 C 20 1 1.1 1.1 AMPS: 22.5 2 20 RECS - CONF 105 A 20 1 0.6 0.6 R-ASE B KVA : 4.8 2 22 RECS- CONF 134,135 B 20 1 1.1 I I 1.1 AMPS : 40.0 2 24 RECS - GREETING AREA 100 C 20 1 0.7 0.7 PHA SEC KVA : 3.9 2 26 RECS - GREETING AREA 100 A 20 1 0.4 0.4 AMPS : 32.5 2 28 RECS - GREETING AREA 100 B 20 1 0.4 0.4 30 SPARE C 20 1 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE B 20 1 KVA : 11.4 36 SPARE C 20 1 AMPS : 31.6 38 SPARE T A 20 1 DEMANDLOAD 40 SPARE B 20 1 KVA : 10.7 42 ISPARE C 20 1 1 1 AM: 29.7 NOTES(REMARKS : 1. EXISTINGCIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEWCI RCUIT BREAKERAS INDICATED DEMAND / DIV ERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES -TO10KVA 100% = 10.0 REMAINNGOVER 10KVA 50% = 0.7 H HEATING 100% = M MOTORS 100% = LM LARGEST MOTOR 125% = L LIGHTING 125% = K KITCHEN (35% = O OTHER 100% _ PANEL:LGE PROJECT NAME BECU TUKWLA PROJECT #: 15110 LOCATION: FLOOR 1 FED FROM 225A DISCONNECT NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 0 AM P R H M L K O TOTAL 2 1 REFER REC- PANTRY 207 A 20 1 1.0 1.0 PANEL AMPS : 200 2 3 - REFER REC - PANTRY 207 - B 20 1 1.0 1.0 FEEDER AMPS : 200 2 5 DED REC - COPY RM 137 C 20 1 1.5 1.5 L- L V OLTS : 208 7 REFRIGERATOR-KTTCHBV627 A 20 1 .8 0.8 L-NVOLTS:9 SPARE B 20 1 PHASE: 3 11 SPARE C 20 1 WIRE: 4 r2 13SPARE A 20 115 SPARE B 20 1 �- 17DED REC - COPY RM 114 C 20 1 1.5 1.5 -- 191 - 21 DED R.E.C. -COPY RM 212 --------- .----- - - - - SPARE A ZO _ _ B 20 1 1.5 . ....__.. 1 --.-.- ................... . ........ --- . 1.5 _--....---.-.. M.L.O. MAN CB X 23 SPARE C 20 1 FLUSH 2 25 RED- 3RD FLR PANTRY REFRIG A 20 11 1 0.8 0.8 SURFACE X 2 27 REC- 3RD FLR PANTRY REFRIG B 20 1 0.8 0.8 ISO GND 2 29 RED- 5TH FLR PANTRY REFRIG C 20 1 1 1.0 1.0 FEED•THRU 2 31 RED- 5TH FLR PANTRY ISLAND REFRIG A 20 1 1.0 1.0 2 33 RED- 5TH FLR PANTRY REFRIG B 20 1 0.8 0.8 2 35 _ DED REC -COPY RM 525 C 20 1 1.5 1.5 2 37 COPIER REC COPY RM 603 A 20 1 1.5 i 1.5 LOAD SUMMARY 39 SPARE B 20 1 ( TOTAL, ALL SECTIONS ) 41 SPARE - C 20 1 REC KVA : 21.3 HEAT KVA : 2 2 RECS - TELLER LINE BACK COUNTER A 20 1 1 0.4 1 0.4 2 4 DID REC - TELLER LINE COPIER B 20 1 1.5 1.5 2 6 DIED REC - OPEN OFFICE 156 COPIER C 20 1 1 1.5 kOTHER 1 1.5 MOTOR KVA : 2 8 DIED REC - 2ND FLR COPY 261 A 20 1 1.5 1.5 LIGHTING KVA IU srARF- B 20 1 KITCHEN KVA . 9.2 12 SPARE C 20 1 --- KVA : 1.5 14 SPARE A 20 1 0.4 0.4 2 16 DIED REC- 3RD FLR COPY 361 B 20 1 1.5 1.5 FHASEA KVA : 12.0 18 SPARE C 20 1 AMPS : 100.0 ZO SPARE A 20 1 PHA SEB KVA : 10.0 2 22 DED REC - 3RD FLR COPY 325 B 20 1 1.5 1.5 AMPS : 83.3 24• SPARE C 20 1 1 PHA SEC KVA : 10.0 2 26 DED REC - 4TH FLR COPY 453 A 20 1 1.5 - _ --- - - 1.5 - AMPS : 83.3 --- 28 - - - SPA RE - 0 -B 2 - 1 - - 2 30 DED REC - 5TH FLR NW OPEN OFFICE COPIER C 20 1 1.5 1.5 2 32 REFRIG- 4TH FLR PANTRY A 20 1 0.6 1.0 1.6 CCNNECTED LOAD 2 34 REFRIG- 4TH FLR PANTRY B 20 1 0.4 1.0 1.4 KVA : 32.0 2 36 DED REC - COPY RM 425 - C 20 1 1.5 1.5 AMPS : 88.8 38 SPA RE A 20 1 DEIVlAND LOA D 2 40 DIED REC - 3RD FLR COPY 649 B 20 1 1.5 1.5 KVA : 23.1 42 1 SPARE - C 20 1 1 AMPS : 64.2 NOTES/REMARKS : 1. EXISTINGCIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND / DIVERSITY FACTORS LOAD DESCRIPTION I DEMAND R REDEFTACLES - TO 10KVA 100% = 10.0 REVIANNGOVER1OKVA 50% = 5.7 H HEATING 100% = M MOTORS 100% = LM LARGEST MOTOR 125% = L LIGHTING 125% = K KITCHEN 65% = 6.0 O OTHER 100% = 1.5 PANEL: LC10 (SECTION 3) PROJECT NAME BECU TUKWLA PROJECT #: 15110 LOCATION: FLOOR 1 FED FROM PANEL LC9 NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 0 AMPI PI R I H7 M L K O TOTAL 85 SPARE A 20 1 PANEL AMPS : 225 87 SPARE B 20 1 1 FEEDER AMPS : 225 89 SPARE C 20 1 L- LVOLTS : 208 91 SPARE A 20 1 L- NVOLTS : 120 93 SPARE B 20 1 1 PHASE : 3 95 SPARE C 20 1 VMRE : 4 97 SPA RE A 1 20 1 99 I SPA RE B 1 20 1 101 SPARE C1 20 11 MIL.O. X 103 SPARE A 20 11 I I MAIN CB FLUSH 105 SPARE B 20 1 107 SPARE C 20 1 SURFACE X 109 SPA RE A 20 1 ISO GND Ill SPARE B 20 1 FEED THRULi 113 115 SPARE SPA RE C 20 A 20 1 _ 1 117 SPA RE B 20 1 119 SPA RE C 20 1 121 SPARE A 20 1 LOADSUMMARY 123 1 SPARE B 1 20 1 (TOTAL, ALL SECTIONS) 125 SPARE C 20 1 RW KVA : 86 SPARE A 20 1 88 SPARE B 20 1 1 1 HEAT KVA : 90 SPARE C 20 1 1 MOTOR KVA : 92 SPARE A 20 1 LIGHTING KVA : 94 SPARE B 1 20 1 KITCHEN KVA : 96 SPARE C 20 1 OTHER KVA : 98 SPARE A 20 1 ...----. 100 ----- 102 SPARE ---- E------ -------- SPARE B 20 b - C ZO 1 ._.... ------ 1 --- - ---- -._-..--...-_.._-.-.. R-IASEA KVA : AMPS 104 SPARE A 20 1 R-ASE B KVA : AMPS : 106 SPARE Ift B 20 1 108 SPARE C 20 1 FHASECKVA : 110 SPARE 1 112 SPARE SPARE SPARE 20 0 4AMPS 114 116 20 1U CONNECTEDLOAD 118 SPARE B 20 1--9--- KVA : 120 SPARE C 20 1 AMPS : 122 SPARE A 20 1 DEMAND LOAD 124 SPARE B 20 1 KVA : 126 SPARE C 20 1 AMPS : NOT ESIREMARKS : 1 1. 2. 3. DEMAND / DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R REDEPTACLES - TO 10KVA 1000/0 = REVIANING OVER 10KVA 50% = H HEATING 1000/0 = M MOTORS 1000/0 = LM LARGESTMOTOR 125% = L LIGHTING 125% _ K KITCHEN 65% R { ; C- L. i �, f O OTHER z , .. !D "WiLA Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 PERMIT SET 8-10-15 . . ..- . REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC SEP 0 4 2015 City of •Tul ila BUILDING DIVISION r---- Project Title: Improvement for: BECU I<WITA TU 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: 1 ST FLR PANEL SCHEDULES Designed By: RB Drawn By: MB Project No: 15110 Date: 08/05/2015 Sheet Number: AUG 1 2 2015 PERMIT CENTER E0.3 PANEL: H2 PROJECT NAME BECU TUKWI LA PROJECT #: 15110 LOCATION FLOOR 2 FED FROM: 225A DISCONNECT NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 9IAMJ P R H I M L K 0 TOTAL 2 1 LTS-ENCLOSED OFFICE AND SUPPORT A 20 1 3.0 3.0 PANEL AMPS : 225 2 3 LTS- ENCLOSED OFFICE AND SUPPORT B -- - 2.8 2.8 FEEDERAMPS : 225 5 - - - C - - - L - L VOLTS : 480 1 7 SPARE A 20 1 L- N VOLTS : 277 1 9 SPARE B 20 1 PHASE : 3 1 11 SPARE C 20 1 WIRE : 4 1 13 SPARE A 20 1 1 15 ISPARE B 20 1 1 17 SPARE C 20 1 1 19 SPARE A 20 1 - M.L.O. 1 21 SPARE B 20 1 MAIN CB X 1 23 SPARE C 20 1 FLUSH SURFACE X 2 25 FPTU 208 A 30 1 4.0 0.7 4.7 2 27 FPTU 206 B 20 1 2.5 1 0.7 3.2 ISO GND 2 29 FPTU 207 C 30 1 3.0 0.7 3.7 FEED-THRU 1 31 SPARE A 40 13 1 33 --- B -- - 1 35 --- C -- - -- 2 37 FTPU202,203,204,205 A 50 3 7.3 1.4 8.7 LOADSUMMARY 2 39 - - - B - - - 7.3 1.1 8.4 ( TOTAL, ALL SECTIONS) 2 41 --- C -- - 7.3 1.1 8.4 REC KVA 2 2 LTS-OPEN OFFICE AND CORRIDOR A 20 1 4.5 4.5 1 4 SPARE B 20 1 1 HEAT KVA : 78.5 MOTOR KVA : 16.8 LIGHTING KVA : 10.3 1 6 SPARE C 20 1 1 8 SPARE A 20 1 1 10 SPARE B 20 1 KITCHEN KVA 1 12 SPARE C 20 1 OTHER KVA 1 14 SPARE A 20 1 - PHASEA KVA : 34.7 2 16 FPTU 225 B 20 1 3.0 0.7 3.7 2 18 FPTU 232 C 20 1 3.0 0.7 3.7 AMPS : 125.3 2 20 FPTU 201 A 20 1 3.0 0.7 3.7 PHASE B KVA : 35.2 3 22 FPTU 231 B 30 1 - 5.0 1.1 6.1 AMPS : 126.9 2 24 FPTU 214 C 20 1 1 3.0 0.7 3.7 PHASE C KVA : 35.7 2 26 FPTU 215 A 20 1 3.0 0.7 3.7 AMPS : 128.9 2 28 FPTU 209 B 20 1 3.0 0.7 3.7 3 30 FPTU 210 Cl30 1 4.5 1.1 5.6 1 32 SPARE A 30 1 1 CONNECTED LOAD 2 34 FPTU 217 B 20 1 0.2 0.7 0.9 KVA : 105.6 2 36 FPTU 216 C 20 1 3.5 0.7 4.2 AMPS : 127.0 2 38 FPTU 211,212,213 A 50 3 5.3 1.1 6.4 DEMAND LOAD 2 40 - - - B - - - 5.3 1.1 6A KVA : 108.5 2 42 - - - C - - - 5.3 1 1.1 1 6.4 AMPS : 130.5 NOTES/REMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BYTHSPROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND! DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES-TO10K1/A 100% _ REMAINING OVER 10KVA 50% _ H HEATING 100% = 78.5 M MOTORS 100% = 15.4 LM LARGEST MOTOR 125% = 1.8 L LIGHTING 125% = 12.9 K KITCHEN 65% _ O OTHER 100% _ PANEL: L2B (SECTION 1) PROJECT NAME BECU TUKWILA PROJECT # 15110 LOCATION FLOOR 2 FED FROM: 225KVA XFMR T2 NOTE CKT NO. CIRCUIT NAME CBSIZE 0 AMP LOAD (KVA) PANEL DESCRIPTION P R H M L K 0 TOTAL 2 1 VENDING REC PANTRY A 20 1 1.0 1.0 PANEL AMPS : 225 2 3 VENDING REC PANTRY B 20 1 1.0 1.0 FEEDERAMPS : 225 L - L VOLTS : 208 2 5 V ENDING REC PANTRY C 20 1 1.0 1.0 2 7 GARBAGE DISPOSAL REC PANTRY A 20 1 1.0 1.0 L - N VOLTS : 120 2 9 DISHWASHER REC PANTRY B 20 11 1.2 1.2 PHASE: 3 2 11 DEDICATED GFCI REC PANTRY COUNTER TOF C 20 11 1.2 1.2 WIRE : 4 2 13 CONVENIENCE GFCI REC PANTRY COUNTER 1 A 20 1 0.5 0.5 2 15 MICROWAVE REC PANTRY B 20 1 1.2 1.2 M.L.O. 2 17 MICROWAVE REC PANTRY C 20 1 1.2 1.2 2 19 COUNTER RECS - COPY RM 212 A 20 1 0.4 0.4 MAIN CB X 2 21 COUNTER RECS - COPY RM 212 B 20 1 0.6 0.6 FLUSH 2 23 DEDICATED GFCI REC PANTRY COUNTER TOF C 20 1 1.2 1.2 SURFACE X 2 25 COWENENCE GFCI REC PANTRY COUNTER 1 A 20 1 0.5 0.5 ISO GND 2 27 DEDICATED GFCI REC PANTRY COUNTER TOF B 20 1 1 1.2 1.2 FEED-THRU X 2 29 CONVENIENCE REC PANTRY/BREAKOUT C 20 1 0.7 0.7 2 31 PROJECTOR A 20 1 0.3 0.3 33 SPARE B 20 1 35 SPARE C 20 1 3 37 NEW TVSS A 20 3 0.1 0.1 LOADSUMMARY 3 39 - - - B - - 0.1 0.1 ( TOTAL, ALL SECTIONS) 3 41 --- C -- - 0.1 0.1 REC KVA : 41.2 2 2 DEDICATE REC TRAINING RM SE A 20 1 1.2 1.2 2 4 DEDICATE REC TRAINING RM SE B 20 1 1.2 1.2 HEAT KVA : 2.0 2 6 COIW ENENCE REC TRAINING RM SE C 20 1 0.5 0.5 MOTOR KVA : 2.1 2 8 PROJECTOR/SCREEN TRAINING RM SE A 20 1 1.0 1.0 LIGHTING KVA : 1.3 10 SPARE B 20 1 KITCHEN K\/A : 11.2 OTHER KVA : 14.0 2 12 FLOOR BOX TRAINING RM SE C 20 11 0.7 0.7 2 14 FLOOR BOX TRAINING RM SE A 20 1 0.7 0.7 2 16 FLOOR BOX TRAINING RM SE B 20 1 0.7 0.7 PFASEA KVA : 24.0 2 18 FLOOR BOX TRAINING RM SE C 20 1 0.7 0.7 AMPS : 200.2 2 20 REC CONF 217 A 20 1 0.9 0.9 PHASE B KVA : 23.7 AMPS : 197.8 2 22 EXH FAN EF2-03 B 20 1 0.7 0.7 2 24 EXH FANS EF2-01,02 C 20 1 1.4 1.4 PI-ASEC KVA : 24.1 26 SPARE A 20 1 AMPS : 200.5 2 28 REC OFFICES 210,211 B 20 1 0.7 1 1 0.7 2 30 CONY RECHALLVVAY LOBBY,STORAGE218 C 20 1 0.5 1 0.5 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE B 20 1 KVA : 71.8 36 SPARE C 20 1 AMPS : 199.4 38 SPARE A 20 1 DEMANDLOAD 40 SPARE B 20 1 KVA : 53.0 42 SPARE C 20 11 1 AMPS : 147.0 NOTESIREMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIREDBYTHIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND! DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES -TO10KVA 100% = 10.0 REMAINING OVER 10KVA 50% = 15.6 H HEATING 100% = 2.0 M MOTORS 100% = 0.7 LM LARGEST MOTOR 125% = 1.8 L LIGHTING 125% = 1.6 K KITCHEN 65% = 7.3 0 OTHER 100% = 14.0 PANEL: L2A (SECTION 2) PROJECT NAME: BECU TUKWILA PROJECT#: 15110 LOCATION: FLOOR 2 FED FROM: PANEL L2B NOTE CKT NO. CIRCUIT NAME CB SIZE 9 AM LOAD (KVA) PANEL DESCRIPTION P R H M L K O TOTAL 2 1 WORK STATIONS NW A 20 11 0.6 0.9 1.5 PANEL AMPS : 225 2 3 WORK STATIONS NW B 20 1 1.2 1.2 FEEDER AMPS : 225 2 5 NW BREAKOUT C 20 1 0.4 0.4 L - L VOLTS : 208 2 7 WORK STATIONS NW A 20 1 1.2 1.2 L - N V OLTS : 120 2 9 1 WORK STATIONS NW B 20 1 1.2 1.2 PHASE: 3 2 11 WORK STATIONS NW C 20 1 1.2 1.2 WIRE: 4 13 SPARE A 20 111 2 15 COUNTER REC COPY RM 261 B 20 1 0.4 0.4 2 17 COUNTER REC COPY RM 261 C 20 1 0.6 0.6 M.L.O. X 19 SPARE A 20 1 MAIN CB 21 SPARE B 20 1 FLUSH SURFACE X 23 SPARE C 20 1 2 25 REC CONVENIENCE HALLWAYS NORTH A 20 1 0.9 0.9 ISO GND 2 27 RECS - COW RM 249 B 20 1 FEED•THRU X 2 29 WORK STATIONS NW C 20 1 0.9 0.9 2 31 WORK STATIONS NW A 20 1 0.9 0.9 2 33 WORK STATIONS NW B 20 1 0.9 0.9 2 35 WORK STATIONS NW C 20 1 0.9 0.9 2 37 WORK STATIONS NW A 20 1 0.9 0.9 LOADSUMMARY (TOTAL, ALL SECTIONS) 2 39 REC OFFICE253 B 20 1 0.4 0.4 41 SPARE C 20 1 REC KVA : 29.6 2 2 WORK STATIONS NE A 20 1 0.8 0.8 2 4 WORK STATIONS NE B 20 1 0.6 1 0.6 HEAT KVA : 2.0 MOTOR KVA 2 6 WORK STATIONS NE C 20 1 0.6 0.6 2 8 WORK STATIONS NE A 20 1 0.8 0.8 LIGHTING KVA : 1.3 2 10 WORK STATIONS NE B 20 1 0.6 0.6 KITCHEN KVA 2 12 WORK STATIONS NE C 20 1 0.6 0.6 OTHER KVA : 13.4 2 14 WORK STATONS NE A 20 1 0.6 0.6 2 16 FLOOR BOX REC, RECS CONF 273 B 20 1 0.7 0.7 PHASE A KVA : 16.4 2 18 RECS - ENC OFF 272, COW 273 C 20 1 0.6 0.6 AMPS : 136.7 20 SPARE A 20 1 PHASE B KVA : 15.1 22 SPARE B 20 1 AMPS : 126.0 2 24 WORK STATIONS NE C 20 1 0.6 1 0.6 PHASE C KVA : 14.8 2 26 WORK STATIONS NE A 20 1 0.6 0.6 AMPS : 123.3 2 28 WORKSTATIONS NE B 20 1 0.4 0.4 2 30 WORK STATIONS NE C 20 1 0.6 0.6 2 32 WORK STATIONS NE A 20 1 0.8 0.8 CONNECTED LOAD 2 34 WORK STATIONS NE B 20 1 0.8 0.8 KVA : 46.3 2 36 WORK STATIONS NE C 20 1 0.6 0.6 AMPS : 128.6 2 38 WORK STATIONS NE A 20 1 0.6 0.6 DEMAND LOAD 40 SPARE B 20 1 KVA : 36.8 2 1 42 1 RELOCATED EXISTING ATM CIRCUIT C 20 1 0.5 1 0.5 1 AMPS : 102.2 1` 0TESIREMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND! DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 10.0 REMAINING OVER 10KVA 50% = 9.8 H HEATING 100% = 2.0 M MOTORS 1000/0 _ LM LARGEST MOTOR 125% _ L LIGHTING 125% = 1.6 K KITCHEN 65% _ 0 OTHER 1000/0 = 13.4 PANEL: L2D (SECTION 4) PROJECT NAME: BECU TUKWILA PROJECT #: 15110 LOCATION FLOOR 2 FED FROM: PANE L2C NOTE CKT NO. CIRCUIT NAME CB SIZE 8 AMP LOAD(KVA) PANEL DESCRIPTION PI R I H M L K O TOTAL 2 1 LTS-OPEN OFFICE A 20 1 0.5 0.5 PANEL AMPS : 225 2 3 LTS-OPEN OFFICE B 20 1 0.5 0.5 FEEDERAMPS : 225 2 5 1 LTS- ENCLOSED OFFICE AND SUPPORT C 20 1 0.1 0.1 L - L VOLTS : 208 7 SPARE A 20 1 L- N VOLTS : 120 9 SPARE B 20 1 PHASE: 3 11 SPARE C 20 1 WIRE: 4 13 SPARE A 20 1 15 SPARE B 20 1 F 17 SPARE C 20 1 M.L.O. X 2 19 EXISTING REC2ND FL BATHROOMS A 20 1 0.4 0.4 MAIN CB 2 21 EXISTING MENS RESTROOM HAND DRYER B 20 1 1.0 1.0 FLUSH 2 23 EXISTING WOMENS RESTROOM HAND DRYE C 20 1 1.0 1.0 SURFACE X 25 SPARE Ar20 1 ISO GND 27 SPARE BF FEED-THRU 29 SPARE C 31 SPARE A33 SPARE B35 SPARE C 37 SPARE A 2011. LOAD SUM MARY ( TOTAL, ALL SECTIONS) 39 SPARE B 20 1 41 SPARE C 20 1 REC KVA : 0.4 2 SPARE A 20 1 4 SPARE B 20 1 HEAT KVA : 2.0 MOTOR KVA 6 SPARE C 20 1 8 SPARE A 20 1 LIGHTING KVA : 1.1 10 SPARE B 20 1 KITCHEN KVA 12 SPARE C 20 1 OTHER KVA 14 SPARE A 20 1 16 SPARE B 20 1 PHASEA KVA : 0.9 18 SPARE C 20 1 AMPS : 7.5 _ 20 SPARE A 20 1 PHASE KVA : 1.5 �- 22 SPARE B 20 1 AMPS : 12.5 24 SPARE C 20 1 PHASE C KVA : 1.1 26 SPARE A 20 1 AMPS : 9.2 28 SPARE B 20 1 30 SPARE C 20 1 32 SPARE A 20 1 CONNECT® LOAD 34 SPARE B 20 1 KVA : 3.5 36 SPARE C 20 1 AMPS : 9.7 38 SPARE A 20 1 DEMANDLOAD 40 SPARE B 20 1 KVA : 3.8 42 SPARE IC 20 1 AMPS : 10.5 NOTES/REMARKS: 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODRED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED LOAD DESCRIPTION DEMAND R RECEPTACLES- TO 10KVA 100% = 0.4 REMAINING OVER 10KVA 50% _ H HEATING 100% = 2.0 M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% = 1.4 K KITCHEN 65% _ 0 OTHER 100% _ PANEL: L2C (SECTION 3) PROJECT NAME BECU TUKWILA PROJECT #. 15110 LOCATION FLOOR FED FROM: PANEL L2A NOTE CKT NO. CIRCUIT NAME CBSIZE () AMPIPI LOAD(K/A) PANEL DESCRIPTION R H M I L K 0 TOTAL 2 1 RECS- OFFICES 235,236,237 A 20 111 0.9 1 0.9 PANEL AMPS : 225 2 3 REC -OFFICES 233,234,235 B 20 1 0.9 0.9 FEEDERAMPS : 225 2 5 REC-OFFICES 233,234,236 C 20 1 1.1 1.1 L - L VOLTS : 208 7 SPARE A 20 1 L- N VOLTS : 120 9 SPARE B 20 1 PHASE : 3 WIRE : 4 11 SPARE C 20 1 2 13 QUAD REC CONFRMSW A 20 1 0.4 0.4 2 15 DEDICATED QUA D REC COW RM SW B 20 1 1.2 1.2 2 17 REC COW RM SW C 20 1 0.7 1 0.7 M.L.O. X 2 19 FLOOR BOX REC COW RM SW A 20 1 0.4 0.4 MA IN CB 2 21 FLOOR BOX REC COW RM SW B 20 1 0.4 0.4 FLUSH 2 23 FLATSCREEN REC COW RM SW C 20 1 1 0.3 0.3 SURFACE X 2 25 RECOFFICES, 221,222,223 A 20 1 0.5 0.5 ISO GND 2 27 REC @ DESKS OFFICES 221,222,223 B 20 1 0.2 0.9 1.1 FEED-THRU X 2 29 REC OFFICE 220 C 20 1 0.2 1 0.3 0.5 31 SPARE A 20 1 33 SPARE B 20 1 35 SPARE C 20 1 37 SPARE A 20 1 LOAD SUM MARY 39 ISFARE B 20 1 ( TOTAL, ALL SECTIONS) 41 ISPARE C 20 1 REC KVA : 10.9 2 2 REC COW RM 252 A 20 1 0.5 0.5 2 4 FLOOR BOX REC, REC COW RM 252 B 20 1 0.4 0.4 HEAT KVA : 2.0 2 6 FLATSCREEN REC COW RM 252 C 20 1 0.3 0.3 MOTOR KVA 2 1 8 REC FILEMORK ROOM A 20 1 0.5 0.5 LIGHTING KVA : 1.3 2 10 WORK STATIONS SW B 20 1 0.9 0.9 KITCHEN KVA 2 12 WORK STATIONS SW C 20 1 0.9 0.9 OTHER KVA : 7.2 2 14 FLOORBOX REC COW RM 239 A 1 20 1 0.4 0.4 2 16 FLATSCREEN REC COW RM 239 B 20 11 0.3 0.3 PI-ASEA KVA : 6.8 2 18 REC COW RM 239 C 20 1 0.5 0.5 AMPS : 56.7 2 20 FLATSCREEN REC COW RM 240 A 20 1 0.3 0.3 PHASE B KVA : 7.9 2 22 FLOORBOX REC COW RM 240 B 20 1 0.4 0.4 AMPS : 66.0 PHASE C KVA : 6.7 2 24 REC COW RM 240 C 20 1 0.5 0.5 2 26 WORK STATIONS SW A 20 1 0.9 0.9 AMPS : 55.8 2 28 WORK STATIONS SW B 1 20 1 0.9 0.9 2 30 CONY REC HA LLVVAY S, OPEN OFFICE 241 CI 20 Ill 0.7 0.7 2 32 CONY REC OPEN OFFICE 24 1, BREA KOUT 215 A 20 Ill 0.9 0.9 CONNECTED LOAD 34 SPARE B 20 1 KVA : 21.4 36 SPARE C 20 1 AMPS : 59.5 38 RELOCATE EXISTING ATM SIGN ON WALKUP A 20 1 0.2 0.2 DEMAND LOAD 40 SPARE B 20 1 KVA : 21.3 AMPS : 59.1 42 ISPARE C 20 1 NOTESIREMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 10.0 REMAINING OVER 10KVA 50% = 0.5 H HEATING 100% = 2.0 M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% = 1.6 K KITCHEN 65% _ 0 OTHER 100% = 7.2 PANEL: LC14 PROJECT NA ME BECU TUKWILA PROJECT #: 15110 LOCATION: FLOOR 2 FED FROM PANEL LC8 NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 AMPI P R H M L K 0 TOTAL 2 1 RECS - OPEN OFFICE 214 A 20 1 1.2 1.2 PANEL AMPS : 100 3 SPARE B 20 1 FEEDERAMPS : 100 2 5 RECS - N OPEN OFFICE 275 C 20 1 0.9 0.9 L - L VOLTS : 208 2 7 RECS - N OPEN OFFICE 276 A 20 1 �1.2 1.2 L - N VOLTS : 120 PHASE: 3 2 9 RECS - N OPEN OFFICE 276 B 20 1 -1.2 1.2 2 11 RECS - N OPEN OFFICE 276 C 20 1 0.9 0.9 WIRE : 4 2 13 RECS - N OPEN OFFICE 276, OFFICE 272 A 20 1 0.9 0.9 2 15 RECS - N OPEN OFFICE 276 B 20 1 0.9 0.9 2 17 RECS - N OPEN OFFICE 276 C 20 Ill0.9 0.9 2 19 RECS - N OPEN OFFICE 276 AF20 1 0.6 0.6 M.L.O. 2 21 RECS - N OPEN OFFICE 276 B 1 �0.9 0.9 MAIN CB23 SPARE C1 FLUSH 25 SPARE A1 SURFACE X 27 SPARE B 1 ISO GND 2 29 RECS - SM CONE 273 C 20 1 0.2 0.2 FEED-THRU 2 31 RECS - OFFICE 253, S M CONF RM 252 A 20 1 0.2 0.3 0.5 2 33 RECS - OFFICES 233,234,235,236,237 B 20 1 1.2 1.2 2 35 RECS - OFFICES 230,231,232,233 C 20 1 0.9 0.9 2 __3T RECS - CONF RM 224 A 20 1 0.7 0.7 LOADSUMMARY 2 39 RECS - COW RM 224 B 20 1 0.7 0.7 ( TOTAL, ALL SECTIONS) 2 41 RECS - COW RM 224 C 20 1 0. 7 0.7 REC KVA : 4.3 2 2 RECS - SW OPEN OFFICE 250 A 20 1 0.9 0.9 2 4 RECS - SW OPEN OFFICE 250 B 20 1 0.9 0.9 HEAT KVA 2 6 RECS - OFFICES 220,221,222 C 20 1 1.2 1.2 MOTOR KVA 2 8 FLOOR BOX - TRANNIG ROOM A 20 1 0.5 0.5 LIGHTING KVA KITCHEN KVA 2 10 FLR BOX REC- CONE ROOM 217 B 20 1 0.4 0.4 2 12 RECS - ENC OFFICES 210,211 C 20 1 0.6 0.6 OTHER KVA : 16.8 2 14 RECS - OPEN OFFICE 241 A 20 1 0.6 0.6 2 16 RECS - FILE ROOM 213 B 20 1 0.7 0.7 PHASEA KVA : 7.1 AMPS : 59.2 18 SPARE C 20 1 20 SPARE A 20 1 PHASE B KVA : 7.5 22 SPARE B 20 1 AMPS : 62.5 24 SPARE C 20 1 PHASE C KVA : 6.5 26 SPARE A 20 1 AMPS : 54.2 2 28 RECS - SW OPEN OFFICE 250 B 20 1 0.6 0.6 2 30 RECS - COW RM 249 C 20 1 0.2 0.2 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE T B 20 1 KVA : 21.1 36 SPARE C 20 1 AMPS : 58.6 38 SPARE A 20 1 DEMAND LOAD 40 SPARE _ B 20 1 KVA : 21.1 42 SPARE C 20 1 AMPS : 58.6 NOTES/REMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED 13Y THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKERAS INDICATED DEMAND! DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES -TO10KVA 100% = 4.3 REMAINING OVER 10KVA 50% _ H HEATING 100% _ M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% _ 0 OTHER 100% = 16.8 RECE!VI-ED CITY OF TUY.WiL A AUG 12 2015 PERMIT CENTER CASE ENGINEERINI-F Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 PERMIT SET 8-10-15 SEP 0 4 2015 City of Tukwila I BUILDING DIVISION Project Title: Tenant Improvement for: BECU TUKWILA 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: 2ND FLR PANEL SCHEDULES Designed By: RB Drawn By: MB Project No: 15110 Date: 08/05/2015 Sheet Number: PANEL: H3 PROJECT NAME BECU TUKWILA PROJECT #: 15110 LOCATION: FLOOR 3 FED FROM: 225A DISCONNECT NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 AMP fP R M L K TOTAL 3 1 LTS-ENCLOSED OFFICES AND SUPPORT A 20 1 1.5 1.5 PANEL AMPS: 225 3 SPACE B JH PO FEEDER AMPS : 225 L- L VOLTS : 480 5 SPACE C 7 SPACE A L- N VOLTS : 277 9 SPACE -� B - - PHASE: 3 11 SPACE C WIRE : 4 13 SPACE A 15 SPACE B 17 SPACE C _ 19 SPACE AlM.L.O. 3 21 FPTU 337 B 1 30 1 4.0 0.7 4.7 MAIN CB X 1 23 EAH- 301 Cl50 1 7.5 7.6 FLUSH 2 25 FPTU 301 A 20 11 1 3.5 0.7 4.2 SURFACE X 2 27 FPTU 320 B 20 1 2.0 0.7 1 2.7 ISO GND 2 29 FPTU 319 C 20 1 3.0 0.7 3.7 FEED-TF RU 2 31 FPTU 318 A 20 1 3.0 0.7 3.7 2 33 FPTU 317 B 20 1 2.7 0.7 3.4 3 35 FPTU 316 C 30 1 4.0 0.7 1 4.7 2 37 FPTU 312,313,314.315 A 50 3 8.5 2.2 10.7 LOADSUMMARY 2 39 - - - B - - - 8.5 1.5 10.0 ( TOTAL, ALL SECTIONS) 2 41 --- C -- - 8.5 1.5 1 1 10,0 REC WA 2 2 LTS-OPEN OFFICE AND CORRIDORS A 20 1 2.1 2.1 2 4 LTS-OPEN OFFICE AND CORRIDORS BI 20 1 3.1 3.1 HEAT WA : 95.6 6 SPARE Cl20 1 MOTOR WA : 18.2 8 SPARE A 20 1 LIGHTING WA : 6.7 10 SPARE W B 20 1 KITCHEN WA 12 SPARE C 20 1 OTHER KVA 14 SPARE A 20 1 16 SPARE BI 20 1 PHASEA WA : 38.5 18 SPACE C AMPS : 139.0 20 SPACE A PHASE B WA : 38.5 22 SPACE B AMPS : 139.0 3 24 FPTU 335 C 20 1 2.0 0.7 1 1 2.7 PHASE C KVA : 43.5 2 26 FPTU 309 A 20 1 2.5 0.7 3.2 AMPS : 157.0 2 28 FPTU 310 B 20 1 2.5 1 0.7 3.2 2 30 FPTU 311 C 20 1 3.5 0.7 4.2 2 32 FPTU 306 A 30 1 5.0 1.1 1 6.1 1 CONNECTED LOAD 2 34 FPTU 338 B 20 1 3.0 0.7 3.7 WA : 120.5 2 36 FPTU 308 C 20 1 3.0 0.7 3.7 AMPS : 144.9 2 38 1 FPTU 302,303,304,305 A 50 3 6.3 0.7 7.0 DEMAND LOAD 2 40 - - - B - 6.3 1.4 7.7 WA : 122.7 2 1 42 - - - ICI 6.3 0.7 7.0 1 AMPS : 147.6 NOTESIREMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUT MODIFIED BY TFIS PROJECT 3. PROVIDE NEW CIRCUT BREAKER AS INDICATED DEMAND! DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES- TO 10KVA 100% _ REMAINING OVER 10KVA 50% _ H HEATING 100% = 95.6 M MOTORS 100% = 16.0 LM LARGEST MOTOR 125% = 2.8 L LIGHTING 125% = 8.4 K KITCHEN 65% _ 0 OTHER 100% _ PANEL: L31) (SECTION 4) PROJECT NAME BECU TUKWILA PROJECT #: 15110 LOCATION: FLOOR4 FED FROM: PANEL L3C NOTE CKT NO. CIRCUIT NAME ICBSIZE BIAMPI LOAD(KVA) PANEL DESCRIPTION PI R I H M I L K 0 TOTAL 1 SPARE A 20 11 PANEL AMPS : 225 3 SPARE B 20 1 FEEDERAMPS : 225 5 SPARE C 20 1 L- L VOLTS : 208 7 SPARE A 20 1 L- N VOLTS : 120 9 SPARE B 20 1 PHASE : 3 11 SPARE C 20 1 WIRE : 4 13 SPARE A 20 1 15 SPARE B 20 1 _ 17 SPARE C 20 1 M.L.O. X 19 SPARE A 20 1 MAIN CB 21 SPARE B 20 1 FLUSH 23 SPARE C 20 1 SURFACE ISO GND X 25 SPARE A 20 1 27 SPARE B 20 11 FEED-THRU 29 SPARE C 20 1 31 SPARE A 20 1 33 SPARE B 20 1 35 SPARE CI 20 1 37 SPARE Al20 1 LOADSUMMARY 39 SPARE B 20 1 ( TOTAL, ALL SECTIONS } 41 SPARE C 20 1 REC KVA 2 SPARE A 20 1 4 SPARE B 20 1 HEAT KVA MOTOR KVA 6 SPARE C 20 1 8 SPARE A 20 1 LIGHTING WA 10 SPARE B 20 1 KITCHEN KVA 12 SPARE C 20 1 OTHER WA 14 SPARE A 20 1 PHASEA KVA 16 SPARE B 20 1 18 SPARE C 20 1 AMPS 20 SPARE A 20 1 PHASE KVA 22 SPARE B 20 1 AMPS 24 SPARE C 20 1 PHASECKVA 26 SPARE A 20 1 AMPS 28 SPARE B 20 1 30 SPARE C 20 1 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE BI 20 1 KVA 36 SPARE C 20 1 AMPS 38 SPARE A 20 1 DEMAND LOAD 40 ISPARE B 20 1 KVA: 42 ISPARE C 20 1 AMPS NOTESIREMARKS : 1. 2. 3. DEMAND DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 1 OKVA 100% _ REMAINING OV ER 10KVA 50% _ H HEATING 100% _ M MOTORS 1000/0 _ LM LARGEST MOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% _ 0 OTHER 100% _ PANEL: L3 (SECTION 1) PROJECT NAME BECU TUKWILA PROJECT #. 15110 LOCATION FLOOR4 FED FROM: 150 KVA XFNIR T4 NOTE CKT NO. CIRCUIT NAME CBSIZE 8 AMP LOAD(KVA) PANEL DESCRIPTION PI R I H M I L K O TOTAL 2 1 LTS-OPEN OFFICES A 20 1 1.6 1.6 PANEL AMPS : 225 2 3 LTS- ENCLOSED SUPPORT B 20 11 1 0.5 0.5 FEEDERAMPS : 225 L - L VOLTS : 208 2 5 RECEPTS - N ROOM SCHEDULERS C 1 D.7 0.7 2 7 WORKSTATIONS WEST A 1 0.6 0.6 L - N VOLTS : 120 2 9 WORKSTATIONS WEST B r 1 0.6 0.6 PHASE : 3 2 11 WORKSTATIONS WEST C 1 0.9 0.9 WIRE : 4 2 13 WORKSTATIONS WEST A 1 0.9 0.9 2 15 WORKSTATIONS WEST B 20 1 0.9 0.9 M.L.O. 2 17 WORKSTATIONS WEST C 20 1 0.6 0.6 2 19 WORKSTATIONS WEST A 20 1 0.6 0.6 MAIN CB X 2 21 WORKSTATIONS SOUTH B 20 1 0.6 0.6 FLUSH 2 23 WORKSTATIONS SOUTH C 20 1 0.9 0.9 SURFACE X 2 25 FLOOR BOX REG CONF RM 304 A 20 11 0.5 0.5 ISO GND 2 27 FLATSCREEN REC CONF RM 304 B 20 1 0.3 0.3 FEED-THRU X 2 29 REC CONF RM 305 C 20 1 0.4 0.4 2 31 FLOOR BOX REC ODNF RM 305 A 20 1 0.4 0.4 2 33 FLATSCREEN REC CONE RM 305 B 20 1 0.3 0.3 2 35 FLOOR BOX REIC CONF RM 303 C 20 1 1 0.4 0.4 2 37 FLATSCREEN REC CONF RM 305 A 20 11 0.3 0.3 LOADSUMMARY 39 SPARE B 20 1 ( TOTAL, ALL SECTIONS) 41 ISPARE C 20 1 REC KVA : 17.4 2 2 1 REC - CONF RM 355 A 20 1 0.3 0.3 2 4 FLOOR BOX REC CONF RM 355 B 20 1 0.4 0.4 HEAT KVA : 8.8 2 6 REC CONF RM 355 Cl20111 0.4 0.4 MOTOR KVA 2 8 REC OFFICE 356 Al20 111 0.2 0.3 0.5 LIGHTING WA : 2.1 2 10 WORK STATION NW B 20 1 0.9 0.9 KITCHEN KVA OTHER WA : 41.4 2 12 WORK STATION NN C 20 1 0.9 0.9 2 14 WORK STATION NV11 A 20 1 0.6 1 0.6 2 16 WORK STATION NN B 20 1 0.6 0.6 PHASEA KVA : 23.9 2 18 WORK STATION NW C 20 1 1.2 1.2 AMPS : 199.2 2 20 WORK STATION NM A 20 1 0.9 0.9 PHASE B KVA : 26.3 2 22 WORK STATION NN B 20 1 1.2 1.2 AMPS : 210.8 2 24 WORK STATION NW C 20 1 0.9 0.9 PHASE C KVA : 20.5 2 26 WORK STATION NW A 20 1 0.9 0.9 AMPS : 170.8 2 28 WORK STATION NW B 20 1 1.2 1.2 2 30 WORK STATION M C 20 1 0.9 0.9 2 32 WORKSTATION NW A 20111 1.2 1.2 CONNECTED LOAD 2 34 WORK STATION NW B 20 1 1.2 1.2 WA : 69.7 2 36 WORK STATION NN C 20 1 1.2 1.2 AMPS : 193.5 3 38 NEW TVSS A 1 20 3 0.1 0.1 DEMAND LOAD 3 40 - - - B - - - 0.1 0.1 KVA : 66.5 3 42 1 - - - Cl - - - 0.1 0.1 AMPS : 184.7 NOTESIREMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 10.0 REMAINING OVER IOWA 50% = 3.7 H HEATING '100% = 8.8 M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% = 2.6 K KITCHEN 65% _ 0 OTHER '100% = 41.4 PANEL: L3E (SECTION 1) PROJECT NA ME BECU TUKWI LA PROJECT #: 15110 LOCATION: FLOOR 3 FED FROM: PANEL LG4 NOTE CKT NO. CIRCUIT NAME CBSIZE 9 AMP LOAD(KVA) PANEL DESCRIPTION P1 R H M L K O TOTAL 2 1 1 DEDICATED QUAD REC STORAGE 318 A 20 1 1.2 1.2 PANEL AMPS : 225 2 3 DEDICATED QUAD REC STORAGE 318 B 20 1 1.2 1.2 FEEDER A MPS : 225 2 5 REC TRAINING 317, STORAGE 308 C 20 1 0.5 0.5 L - L VOLTS : 208 2 7 PROJECTOR/SCREEN EAST TRAINING RM 317 A 20 1 1.0 1.0 L - N VOLTS : 120 2 9 PROJECTOR/SCREEN WEST TRAINING RM 3'17 B 20 1 1.0 1.0 PHASE : 3 WIRE : 4 2 11 FLOOR BOX WEST TRAINING RM 317 C 20 1 0.7 0.7 2 13 FLOOR BOX WEST TRAINING RM 317 A 20 1 0.7 0.7 2 15 COUNTER RECS - COPY 325 B 20 1 0.4 0.4 2 17 COUNTER RECS - COPY 325 C 20 1 0.6 - 0.6 M.L.O. 19 SPARE A 20 1 MAINCB X 21 SPARE B 20 1 FLUSH 23 SPARE C 20 1 SURFACE ISO GND X 25 SPARE A 20 1 27 SPARE B 20 1 FEED-THRU X 29 SPARE C 20 1 31 SPARE A 20 1 33 SPARE B 20 1 35 SPARE C 20 1 37 SPARE A 20 1 LOADSUMMARY 39 SPARE B 20 1 ( TOTAL, ALL SECTIONS ) 41 SPARE C 20 1 REC KVA : 14.9 2 2 DEDICATED COPIER REC COPY RM 325 A 20 1 1.2 1.2 2 4 REC COPY RM 325 B 20 1 0.4 1 0.4 HEAT KVA : MOTOR KVA : 2 6 REC COPY RM 325 C 20 1 0.5 0.5 2 8 FLOOR BOX REC CONF RM 321 A 20 1 0.4 0.4 LIGHTING KVA 2 10 FLATSCREEN REC CONF RM 321 B 20 1 0.3 0.3 KITCHEN WA : 8.2 2 12 REC CONF RM 321,PHONE RMS 319,320 C 20 1 0.9 1 1 0.9 OTHER KVA : 3.0 2 14 WORK STATIONS SE A 20 1 1 0.9 0.9 PI-ASEA KVA : 8.7 2 16 WORK STATIONS SE B 20 1 0.9 0.9 2 18 WORK STATIONS SE C 20 1 1.2 1 1.2 AMPS : 72.5 20 SPARE A 20 1 PHA SEB KVA : 8.0 22 SPARE B 20 1 AMPS : 66.7 24 SPARE C 20 1 PHASECKVA : 9.4 26 SPARE A 20 11 AMPS : 78.3 28 SPARE B 20 1 30 SPARE C 20 1 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE B 20 1 WA : 26.1 AMPS : 72.4 36 SPARE C 20 1 38 SPARE A 20 1 DEMAND LOAD 40 SPARE B 20 1 KVA : 20.8 42 SPARE C 20 1 AMPS : 57.7 NOTES/REMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND R RECEPTACLES - TO 10KVA 100% = 10.0 REMAINING OVER 10KVA 50% = 2.5 H HEATING 1000/0 _ M MOTORS 1000/0 _ LM LARGEST MOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% = 5.3 0 OTHER 100% = 3.0 L5�✓� PANEL: OB (SECTION 2) PROJECT NAME BECU TUKWI LA PROJECT #. 15110 LOCATION: FLOOR 4 FED FROM: PA NEL L3 NOTE CKT NO. CIRCUIT NAME CBSIZE 8 AMPl LOAD(KVA) PANEL DESCRIPTION PI R I H M L K O TOTAL 2 1 WORK STATIONS SOUTH A 20 1 0.9 0.9 PANEL AMPS : 225 2 3 WORK STATIONS SOUTH B 20 1 1.2 1.2 FEEDER AMPS : 225 L - L VOLTS : 208 2 5 WORK STATIONS SOUTH C 20 1 0.9 0.9 2 7 WORK STATIONS SOUTH A 20 1 0.9 0.9 L - N VOLTS : 120 2 9 WORK STATIONS SOUTH B 20 1 1.2 1.2 PHASE: 3 11 SPARE C 20 111 WIRE : 4 2 13 REC OFFICES 332,333 A 20 11 0.4 0.6 1.0 2 15 WORK STATIONS SE B 20 1 0.9 0.9 M.L.O. X 2 17 WORKSTATIONS SE C 20 1 0.9 0.9 19 SPARE A 20 1 MAIN CB 2 21 WORK STATIONS SE B 20 1 1.2 1.2 FLUSH 2 23 WORK STATIONS SE C 20 1 1.2 1.2 SURFACE X 2 25 WORK STATIONS SE A 20 1 1.2 1.2 ISO GND 2 27 WORK STATIONS SE B 20 1 1.2 1.2 FEED•THRU X 2 29 WORKSTATIONS SE C 20 1 1.2 1.2 2 31 WORK STATIONS SE A 20 1 0.9 0.9 2 r2 33 WORK STATIONS SE B �20 1 1.2 1.2 35 WORKSTATIONS SE C 2D 1 1.2 1.2 2 37 CONVENIENCE REC HALLWAYS NE,SE A 20 1 1.3 1.3 LOAD SUM MARY 2 39 WORK STATIONS NE B 20 1 0.9 0.9 ( TOTAL, ALL SECTIONS) 2 41 CONVENIENCE REC HALLWAYS NN,SW C 20 1 1.3 1.3 REC WA : 8.6 2 SPARE A 20 1 4 SPARE B 20 1 HEAT KVA : 8.8 6 SPARE C 2011. 1 1 MOTOR WA LIGHTING KVA 8 SPARE A 20 1 2 10 REC CONF RM 349, PHONE RMS 347,348 B 20 11 1.1 1.1 KITCHEN KVA 2 12 FLATSCREEN REC CONE RM 349 C 20 1 0.3 0.3 OTHER WA : 24.6 2 14 WORK STATIONS NW A 20 1 1.2 1.2 2 16 WORKSTATIONS NW, FLOOR BOX BREAKOUT B 20 1 0.4 0.6 1.0 PHASEA KVA : 14.5 2 18 WORKSTATIONS SW C 20 1 1.2 1.2 AMPS : 120.8 2 20 WORK STATIONS SW A 20 1 0.6 0.6 PHASE B KVA : 16.5 2 22 WORKSTATIONS SW B 20 1 0.9 0.9 AMPS : 137.5 2 24 WORK STATIONS SW C 20 1 0.9 0.9 PHASE C WA : 11.0 2 ^ 26 WORK STATIONS SW A 20 1 0.6 0.6 AMPS : 91.7 2 28 WORK STATIONS NW B 20 1 0.6 0.6 30 SPARE C 20 1 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE B 20 1 KVA : 42.0 36 SPARE C 20 1 AMPS : 116.6 2 38 WORK STATIONS SOUTH JA 20 1 0.9 0.9 DEMAND LOAD 2 40 REC CAT LAB 341 1 B 20 1 0.6 0.6 KVA : 42.0 42 ISPARE Ic 20 1 AMPS : 116.6 NOTES(REMARKS : 1, EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BYTHS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES- TO 10KVA 100% = 8,6 REMAINING OVER 10KVA 50% _ H HEATING 100% = 8.8 M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% _ O OTHER 100% = 24.6 PANEL: L3F (SECTION 2) PROJECT NAME: BECU TUKWI LA PROJECT #: 15110 LOCATION: FLOOR 3 FED FROM: PANEL L3E NOTE CKT NO. CIRCUIT NAM E 9 CB SIZE LOAD (KVA) PANEL DESCRIPTION NMI PI R H M L K 1 O TOTAL 1 SPARE A 20 1 PANEL AMPS: 225 3 SPARE B 20 1 FEEDERANPS : 225 2 5 DEDICATED REC PANTRY C 20 1 1.2 1.2 L - L VOLTS : 208 2 7 GARBAGE DISPOSAL REC PANTRY A 20 1 1.2 1.2 L- N VOLTS : 120 2 9 DISHJVASHER REC PANTRY B 20,1 1.2 1.2 PHASE: 3 2 11 DEDICATED GFCI REC PANTRY COUNTER TOP C 20 1 1.2 1 1.2 WIRE : 4 2 13 COW ENIENCEGFCI REC PANTRY COUNTERTOP A 20 1 0.7 0.7 2 15 MICROWAVE REC PANTRY B 20 1 1.2 1.2 2 17 MICROWAVE REC PANTRY - C 20 1 1.2 1.2 M.L.O. X 2 19 REC BREAKOUT 309,STORAGE 310,QUIET 308 A 20 1 0.9 0.9 MAIN CB 2 21 RECWELLNESS311 B 20 1 0.5 0.5 FLUSH 2 23 FLOOR BOX REC BREAKOUT 309 C 20 1 0.4 0.4 SURFACE ISO GND X 2 25 COUNTER REC PANTRY 307 A 20 1 0.5 0.5 27 SPARE B 20 1 FEED-THRU X 29 SPARE C 20 1 31 SPARE A 20 1 33 SPARE B 20 1 1 1 35 SPARE C 20 1 37 SPARE A 20 11 LOADSUMMARY 2 39 FLOOR BOX, WALL REC PANTRY B 20 1 0.9 0.9 ( TOTAL, ALL SECTIONS ) 2 41 REC U/C REFERS PANTRY? C 20 1 1.0 1.0 REC KVA : 3.9 2 SPARE A 20 1 4 SPARE B 20 1 HEAT KVA MOTOR KVA 6 SPARE C 20 1 8 SPARE A 20 1 LIGHTING WA 10 SPARE B 20 1 KITCHEN KVA : 8.2 12 SPARE C 20 1 OTHER WA 14 SPARE A 20 1 PHASEA KVA : 3.3 16 SPARE B 20 1 18 SPARE C 20 1 A MPS : 27.5 20 SPARE A 20 1 PHASE B KVA : 3.8 22 SPARE B 20 1 AMPS : 31.7 24 SPARE C 20 1 _ PHASE C WA : 5.0 26 SPARE A 20 1 AMPS : 41.7 28 SPARE B 20 1 30 SPARE C 20 1 32- SPARE A 20 1 CONNECTED LOAD 34 SPARE B 20 1 KVA : 12.1 36 SPARE C 20 1 AMPS : 33.6 38 SPARE A 20 1 DEMAND LOAD 40 SPARE B 20 1 WA : 9.2 42 SPARE C 20 1 AMPS : 25.6 NOTES/REMARKS: 1. EXISTINGCIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 3.9 REMAINNG OVER 10KVA 50% _ H HEATING 100% _ M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% = 5.3 0 OTHER 100% _ PANEL: L3C (SECTION 3) PROJECT NA ME BECU TUKWI LA PROJECT #: 15110 LOCATION: FLOOR4 FED FROM: PANEL L313 ATE CKT NO. CIRCUIT NAME CBSIZE 8 AMPAMPI LOAD(KVA) P1 R IH M L 1 1 EXISTING MENS RESTROOM HAND DRYER A 20 111 1 1.0 1 3 EXISTING WOMENS RESTROOM HA ND DRY ER B 20 1 5 EXISTING REC RESTROOM SINKS C 20 1 0.7 1 7 EXISTING DEDICATED REC SECURITY RISER A 20 1 1 9 EXISTING READER BOARD? B 20 1 2 11 EXISTING F/A STROBE POWER SUPPLY C 20 1 2 13 COUNTER RECS - COPY 361 A 20 Ill 0.4 15 OOUNTER REDS -COPY 361 B -20-11 0.6 K I 0 I TOTALI PANEL DESCRIPTION 1.0 PANEL AMPS : 225 FEEDER AMPS : 225 L - L VOLTS : 208 L - N VOLTS : 120 PHASE : 3 WIRE : 4 1.0 0.7 0.2 0.2 0.2 0.2 0.5 0.5 0.4 17 j SPARE Cj 20 111 ML.O. X 19 SPARE A 20 1 MAIN CB 21 SPARE B 20 11 FLUSH 23 SPARE C 20 1 SURFACE X 25 SPARE A 20 1 ISO GND 27 SPARE B 20 1 FEED-THRU X 29 ISPARE C 20 1 31 SPARE A 20 1 33 SPARE B 20 1 35 SPARE C 20 1 _ 37 SPARE A 20 1 1 LOADSUMMARY 39 SPARE B 20 1 (TOTAL. ALL SECTIONS) 41 SPARE C 20 1 REC WA : 1.7 2 2 EXH FANS EF3-01, 02 A 20 11 1.4 1.4 2 4 EXH FANS EF3-03 B 20 1 0.7 0.7 HEAT KVA : 8.8 2 6 EXH FANS EF3-04 C 20 1 0.7 0.7 MOTOR KVA 3 8 HEAT PUMP HR-301 A 30 2 2.0 2.0 LIGHTING KVA 3 10 - - - B - - - 2.0 2.0 KITCHEN WA OTHER KVA : 0.9 12 SPARE C 20 1 14 SPARE A 20 1 16 SPARE B 20 1 PHASEA WA : 5.0 18 SPARE C 20 1 AMPS : 41.7 20 SPARE A 20 1 PHASEB KVA : 4.5 22 SPARE B 20 1 AMPS : 37.5 24 SPARE iC 20 11 PHASECKVA : 1.9 ?F RPARF IA1 20 Ill AMPS : 15.8 28 1 SPARE B 20 11 1 1_ 30 SPARE C 20 1 3 32 SPARE A 20 1 CONNECTED LOAD 3p. b 34 SPARE B 20 1 KVA 36 SPARE C 20 1 AMPS : 31.6 38 SPARE A 20 1 DEMAND LOAD 40 SPARE B 20 1 KVA : 11.4 42 1 SPARE C 20 1 AMPS : 31.6 NOTES/REMARKS: 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = REMAINING OVER 10KVA 50% _ H HEATING 100% = M MOTORS 1000/0 _ LM LARGEST MOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% = 0 OTHER 1000/0 = 1.7 8.8 0.9 PROJECT NAME: BECU TUKWI LA LOCATION: FLOOR 3 NOTE CKT CIRCUIT NAME NO. I I -A - IVC V VV(V\J IH I IVI VJ 3 WORK STATION NE, OFFICE 356 5 RECS - NE WORKSTATIONS 7 RECS - NE WORKSTATIONS 9 RECS - NE WORKSTATIONS 11 RECS - NE WORKSTATIONS 13 RECS - NE WORKSTATIONS 15 RECS - NE WORKSTATIONS 17 RECS - NE WORKSTATIONS 19 SPARE 21 RECS - NW WORKSTATIONS 23 RECS - NW WORKSTATIONS 25 RECS - SE WORKSTATIONS 27 RECS - SEWORKSTATIONS 29 REDS - SEWORKSTATIONS 31 RECS-SE WORKSTATIONS 33 RECS - OFFICE 331,332 35 SPARE 37 SPARE 39 SPARE 41 SPARE 2 FLR/WALL RECS - TRAINING RM 4 FLRAtiNALL RECS - TRAINING RM 6 FLR REC- CONF 349 8 FLR REC- CONF 321 10 RECS - EAST WORKSTATIONS 12 RECS - EAST WORKSTATIONS 14 REDS - SW WORKSTATIONS 16 RECS - SW WORKSTATIONS 18 RECS - SW WORKSTATIONS 20 RECS - SOUTH WORKSTATIONS 22 RECS - SOUTH WORKSTATIONS 24 RECS --SOUTH WORKSTATIONS 26 RECS - SOUTH WORKSTATIONS 28 SPARE 30 SPARE 32 SPARE 34 SPARE 36 SPARE 38 SPARE 40 SPARE 42 SPARE NOTES/REMARKS : 1. 2. 3. PANEL: LC11 FED FROM: PA NEL LC7 (5TH FLOOR) CBSIZE LOAD(KVA) BIAMPIPI R I H I M I L K PROJECT #: 15110 O TOTALl PANEL DESCRIPTION 0.9 0.9 PANEL AMPS : 100 1.2 1.2 FEEDERAMPS : 100 0.9 0.9 L- L VOLTS : 208 A 20 111 1 0.9 0.9 L - N V OLTS : 120 PHASE : 3 WIRE : 4 M L.O. MAIN CB X FLUSH SURFACE X ISO GND FEED-THRU B 20 1 1.2 1.2 C 20 1 1.2 1.2 A 20 1 0.9 0.9 B 20 1 0.9 0.9 C 20 1 0.9 0.9 A 20 1 B 20 1 0.9 0.9 C 20 1 0.9 0.9 A 20 1 1.2 1.2 B 20 1 1.2 1.2 C 20 1 0.9 0.9 A 20 1 0.9 0.9 B 20 1 0.6 0.6 C 20 1 _ A 20 1 LOADSUMMARY ( TOTAL, ALL SECTIONS) B 20 1 C 20 1 REC KVA : 1.8 HEAT KVA MOTOR WA LIGHTING KVA KITCHEN KVA OTHER WA : 24.3 PHASEA KVA : 8.7 AMPS : 72.5 PHASE B KVA : 9.5 AMPS : 79.2 1 PHASE C WA : 7.9 I AMPS : 65.8 A 20 1 0.5 0.5 B 20 1 0.5 0.5 C 20 1 0.4 _ 0.4 A 20 1 0.4 0.4 B 20 1 1.2 1.2 C 20 1 1.2 1.2 A 20 1 1.2 1.2 B 20 1 0.9 0.9 C 20 1 0.9 0.9 A 20 1 0.9 0.9 B 20 1 0.9 0.9 C 20 1 0.6 0.6 A 20 1 0.9 0.9 B 20 1 _ C 20 1 A 20 1 B 20 1 _ C 20 1 A 20 1 B 20 1 C 20 1 DEMAND! DIVERSITY FACTORS LOAD DESCRIPTION R H M LM L K O RECEPTACLES - TO 10KVA REMAINING OVER 10KVA HEATING MOTORS LARGEST MOTOR LIGHTING KITCHEN OTHER KVA AMPS ND LOAD KVA AMPS 50% 100% 100% 125% 125% 65% 100% TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 la; "'A T-1 a ^a� toy^d ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 ID 26.1 72.4 SEP 0 4 2015 72.4 = 24.3 RECEIV D CITY OF TUKWILA AUG 12. 2015 PERMIT CENTER City Of Tukwila. BUILDING -DIMS)" Tenant Improvement for: BECU TUKWILA 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: 3RD FLR PANEL SCHEDULES Designed By: RB Drawn By: MB Project No: 15110 Date: 08/05/2015 Sheet Number: PANEL: H4 PROJECT NAME BECUTUKWILA PROJECT#: 15110 LOCATION: FLOOR 4 FED FROM: 225A DISCONNECT NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD (KVA) PANEL DESCRIPTION 8AM P R H M L K 0 TOTAL 2 1 LTS- ENCLOSED OFFICE AND SUPPORT A 20 1 1.7 1.7 PANEL AMPS : 225 2 3 LTS- ENCLOSED OFFICE AND SUPPORT B 20 1 1.5 1.5 FEEDER AMPS : 225 L- L VOLTS : 480 5 SPARE C 20 1 7 SPARE A 20 1 L- N VOLTS: 120 9 SPARE B 20 1 PHASE: 3 11 SPARE C 20 1 WIRE: 4 13 SPACE A 15 SPACE B 17 SPACE C 19 SPACE A M.L.O. 2 21 FPTU 409 B 20 11 2.5 0.7 3.2 MAIN CB X 2 23 FPTU 410 C 20 1 3.0 0.7 3.7 FLUSH 3 25 FPTU 407 A 30 1 4.0 0.7 4.7 SURFACE X 2 27 FPTU 408 B 20 1 3.5 0.7 4.2 ISO GND 2 29 FPTU 411 C 20 1 3.5 0.7 4.2 FEED-THRU 31 SPA RE A 30 3 33 --- B -- 35 --- C -- - 2 37 FPTU 402, 403, 404, 406 A 40 3 6.6 0.7 7.3 LOADSUMMARY 2 39 - - - B - - - 6.6 1.1 7.7 ( TOTAL, ALL SECTIONS) 2 41 --- C -- - 6.6 1.4 8.0 REC KVA 2 2 LTS•OPEN OFFICEAND CORRIDOR A 20 1 2.6 2.6 2 4 LTS-OPEN OFFICEAND CORRIDOR B 20 1 2.3 2.3 HEAT KVA : 82.6 6 SPARE C 20 1 MOTOR KVA : 15.5 8 SPARE A 20 1 LIGHTING KVA : 8.1 10 SPARE B 20 1 KITCHEN KVA 3 12 FPTU 412A C 30 1 4.0 0.7 4.7 OTHER KVA 2 14 FPTU 405 A 20 1 3.0 0.7 3.7 16 SPACE B PHASEA KVA : 35.7 18 SPACE C AMPS: 297.5 20 SPACE A I PHASE B KVA : 34.5 22 SPACE B AMPS : 287.5 24 SPACE C PHASE C KVA : 36.0 2 26 FPTU 401 A 20 1 3.5 0.7 4.2 AMPS: 300.0 2 28 FPTU 420 B 20 1 j 2.5 0.7 3.2 2 30 FPTU 419 C 20 1 3.0 0.7 3.7 2 32 FPTU 418 A 20 1 3.5 0.7 4.2 CONNECTED LOAD 3 34 FPTU 417 B 30 1 4.0 0.7 4.7 KVA : 106.2 2 36 FPTU 416 C 20 1 3.0 0.7 3.7 AMPS : 127.7 2 38 FPTU 412,413, 414, 415 A 50 3 6.6 0.7 7.3 DEMAND LOAD 2 40 --- B -- - 6.6 1.1 7.7 KVA : 108.6 2 42 - - - C - - -1 6.6 1.4 8.0 AMPS : 130.6 NOTES]REMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS I NDICATED DEMAND DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 101<VA 100% _ REMAINING OVER 10KVA 50% _ H HEATING 100% = 82.6 M MOTORS 100% = 14.1 LM LARGEST MOTOR 125% - 1.8 L LIGHTING 125% = 10.1 K KITCHEN 65% _ O OTHER 100% _ PANEL: L4G (SECTION 1) PROJ ECT NAME BEC U TUKWI LA PROJECT #: 15110 LOCATION: FLOOR 4 FED FROM: 75 KVA XFMR NOTE CKT NO. CIRCUIT NAME CB SIZE 8 AM P LOAD (KVA) PANEL DESCRIPTION R H M L K O TOTAL 2 1 DEDICATED QUAD REC STORAGE 418 A 20 1 1.2 1.2 PANEL AMPS : 225 2 3 DEDICATED QUAD REC STORAGE 418 B 20 1 1.2 1.2 FEEDER A MPS : 225 L - L VOLTS : 208 2 5 CONY REC STORAGE 418, TRAINING RM 417 C 20 1 0.5 0.5 2 7 REC PRONSCREEN TRAINING CONF RM 417 B A 20 1 1.0 1.0 L - N VOLTS : 120 2 9 REC PRONSCREEN TRAINING CONF RM 417W B 20 1 1,0 1.0 PHASE : 3 WIRE : 4 2 11 REC QUAD TRAINING CONF RM 417 EAST,WE C 20 11 0.7 0.7 2 13 FLOOR BOX REC TRAINING CONF RM WEST A 20 11 0.7 _ 0.7 2 15 FLOOR BOX REC TRAINING OONF RM WEST B 20 1 0.7 0.7 2 17 FLOOR BOX REC TRAINING CONF RM WEST C 20 1 0.7 0.7 M.L.O. 2 19 RECS - V IP CONF RM 410 A 20 1 0.7 0.7 MA IN CB X 2 21 VIDEO REC- VIP CONF RM 410 B 20 1 0.3 0.3 FLUSH 2 23 FLOOR BOX REC TRAINING CONF RM EAST C 20 1 0.7 0.7 SURFACE X 2 25 FLOOR BOX REC TRAINING OONF RM EAST A 20 11 0.7 0.7 ISO GND 2 27 FLOOR BOX REC TRAINING OONF RM EAST B 20 11 0.7 0.7 FEED-THRU X 29 C 20 1 31 A 20 1111 33 B 20 1 35 C 20 1 3 37 NEW IV SS A 20 3 0.1 0.1 LOADSUMMARY 3 39 -- - B - - - 0.1 0.1 ( TOTAL, ALL SECTIONS ) 3 41 - C -- - 0.1 0.1 REC KVA : 25.1 2 SPACE ONLY A 20 11 4 SPACE ONLY B 20 1 HEAT KVA 6 SPACE ONLY C 20 1 MOTOR KVA 8 SPACE ONLY A 20 1 LIGHTING KVA 10 SPACE ONLY B 20 1 KITCHEN KVA : 20.2 12 SPACE ONLY C 20 1 OTHER KVA : 17.3 2 14 WORK STATIONS SW A 20 1 1.2 1.2 2 16 WORK STATIONS SW B 20 1 0.9 0.9� PHASEA KVA : 21.8 2 18 WORK STATIONS SW C 20 1 1.2 1.2 AMPS : 181.7 2 20 WORKSTATIONS SW A 20 1 1.2 1.2 PHASE B KVA : 21.1 AMPS : 175.8 2 22 WORK STATIONS SW B 20 1 1.2 1.2 2 24 WORK STATIONS SW C 20 1 1.2 1.2 PHASEC KVA : 19.7 2 26 WORK STATIONS SW A 20 1 1.2 1.2 AMPS : 164.2 28 SPARE B 20 1 - 1.5 1.5 30 SPARE C 20 1 32 SPARE A 20 1 CONNECTED LOAD 2 34 REC CONF RM 421, PHONE RMS 419,420 B 20 1 0.9 0.9 KVA : 62.6 2 36 FLOOR BOX REC CONF 421 C 20 1 0.4 0.4 AMPS : 173.8 2 38 FLATSCREEN REC CONF 421 A 20 1 0.3 0.3 DEMAND LOAD 40 B 20 1 KVA : 48.0 42 C 20 1 AMPS : 133.2 NOTES/REMARKS: 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 1000/0 = 10.0 REMAINING OVER 1OKVA 50% = 7.6 H HEATING 1000/0 _ M MOTORS 1000/0 _ LM LARGEST MOTOR 125% _ L LIGHTING 125% _ K Krra-IEN 65% = 13.1 0 OTHER 1000/0 = 17.3 PANEL: L4 PROJECT NAME BECU TUKWILA PROJECT #: 15110 LOCATION: FLOOR 4 FED FROM: 225A DISCONNECT NOTE CKT NO. CI RCUIT NAM E CB SIZE LOAD (KVA) PANEL DESCRIPTION 6 AM P R H M L K O TOTAL 2 1 LTS- ENCLOSED SUPPORT A 20 1 0.5 0.5 PANEL AMPS : 225 2 3 LTS-OPEN OFFICE B 20 1 0.5 0.5 FEEDER AMPS : 225 L - L VOLTS : 208 2 5 COUNTER RECS - COPS( 425 C 20 1 0.4 0.4 2 7 COUNTER RECS - COPY 425 A 20 1 0.6 0.6 L - N VOLTS : 120 9 SPARE B 20 1 PHASE : 3 11 SPARE C 20 1 WRE : 4 13 SPARE A 20 1 15 SPARE B 20 1 17 SPARE C 20 1 19 SPARE A 20 1 M.L.O. 21 SPARE B 20 1 IVIAINCB X 23 SPARE C 20 1 FLUSH 25 SPARE A 20 1 SURFACE X 27 SPARE B 20 1 ISO GND FEED-THRU 29 SPARE C 20 1 31 SPARE A 20 1 33 SPARE B 20 1 35 SPARE C 20 1 37 NEW TVSS A 20 3 0.1 0.1 LOADSUMMARY 39 - - - B - - - 0.1 0.1 ( TOTAL, ALL SECTIONS) 41 --- C -- - 0.1 0.1 REC KVA : 13.8 2 2 REC CONF RM 440, OFFICE 445 Al20 1 0.9 0.9 2 4 FLOOR BOX REC CONF RM 410 B 20 1 0.4 0.4 HEAT I(VA 2 6 FLATSCREEN REC OONF RM 410 C 20 1 0.3 0.3 0.6 MOTOR KVA 2 8 REC BREAKOUT 406 A 20 1 0.5 0.5 LIGHTING KVA : 1.0 2 10 REC BREAKOUT 406 B 20 1 0.5 0.5 KITCHEN KVA : 0.3 OTHER KVA : 1.4 2 12 REC N OPEN OFF AREA, PHONE RMS 461,462 C 20 1 0.7 0.7 2 14 RECS - LG CONF RM 460 Al20 1 0.7 0.7 2 16 RECS - LG CONF RM 460 B 20 1 0.5 0.5 PHASE A KVA : 6.3 2 18 REC PROJECTORISCREEN CONF RM 460 C 20 1 0.8 0.8 AMPS : 52.5 2 20 RECS - SM CONF RM 458 A 20 1 0.9 0.9 PHASE B I(VA : 4.3 2 22 COUNTER RECS - COPY 453 B 20 1 0.4 0.4 A MPS : 35.8 2 24 COUNTER RECS - COPS' 453 C 20 1 0.6 0.6 PHASE C INA : 5.9 26 SPARE A 20 1 0.7 0.7 AMPS : 49.2 28 SPARE B 20 1 0.7 1 0.7 30 SPARE C 20 1 0.7 0.7 32 SPA RE A 20 1 0.7 0.7 CONNECTED LOAD 34 SPARE B 20 1 0.7 0.7 KVA : 16.5 36 SPARE C 20 1 0.7 0.7 AMPS : 45.8 38 SPARE A 20 1 0.7 0.7 DEMANDLOAD 40 SPARE B 20 1 0.5 j j 0.5 INA : 14.7 2 42 COW REC HALLWAYS EAST C 20111 1.3 1 11.3 AMPS : 40.9 NOTES/REMARKS: 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND] DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES- TO 1OKVA 100% = 10.0 REMAINING OVER 10KVA 50% = 1.9 H HEATING 100% _ M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% = 1.3 K KITCHEN 65% = 0.2 0 OTHER 100% = 1.4 PANEL: L4H (SECTION 2) PROJECT NA ME BECU TUKWI LA PROJECT #: 15110 LOCATION: FLOOR4 FED FROM: PANEL L4G NOTE CKT NO. CIRCUIT NAME CBSIZE 6 AMPI LOAD(KVA) PANEL DESCRIPTION R H M L K 1 0 TOTA L 2 1 REFER REC PANTRY A 20 1 1.0 1.0 PANEL AMPS : 225 2 3 REFER REC PANTRY B 20 1 1.0 1.0 FEEDERAMPS : 225 L - L VOLTS : 208 2 5 DEDICATED GFCI REC PANTRY COUNTER TOP C 20 1 1.2 1.2 2 7 GARBAGE DISPOSAL REC PANTRY A 20 1 1.2 1.2 L- NVOLTS : 120 2 9 DISHWASHER REC PANTRY B 20 1 1.2 1.2 PHASE : 3 WIRE : 4 2 11 OONVENIEIVCE GFCI REC PANTRY COUNTER I C 20 11 0.5 0.5 2 13 DEDICATED GFCI REC PANTRY COUNTER TOP A 20 1 1.2 1.2 2 15 MCROWAV E REC PANTRY B 20 1 1.2 1.2 2 17 MICROWAVE REC PANTRY C 20 1 1.2 1.2 M. L.O. X 2 19 FLOOR BOX REC CONF RM 415 A 20 1 MAIN CB 2 21 REC CONF RM 415 B 20 1 0.4 0.4 FLUSH 2 23 FLATSCREEN REC CONF RM 415 C 20 1 0.3 0.3 SURFACE X 2 25 REC OONF RM 414 A 20 1 0.4 0.4 ISO GND 2 27 FLOOR BOX REC CONF RM 414 B 20 1 0.4 0.4 FEED-THRU Ll 2 29 FLATSCREEN REC CONF 414 C 20 1 0.3 0.3 2 31 UNDER COUNTER REFERS ISLAND PANTRY? A 20 1 1.0 1.0 2 33 FLOOR BOX REC PANTRY B 20 1 0.4 0.4 2 35 REC NFC 411, RECORD 412,STORAGE 413 C1 20 1 0.4 0.9 1.3 37 ISPARE _A1 20 1 LOAD SUM MARY 39 SPARE B 20 1 ( TOTAL, ALL SECTIONS) 41 SPARE C 20 1 RECKVA : 17.4 2 PANEL L3E A 225 3 6.6 1.2 0.9 8.7 4 --- B -- - 4.7 2.4 0.9 8.0 HEATKVA 6 - - - C - - - 3.6 4.6 1.2 9.4 MOTOR KVA 8 SPARE A 20 1 LIGHTING KVA 10 SPARE B 20 1 KITCHEN KVA : 19.9 12 SPARE C 20 1 OTHER KVA : 3.0 14 SPARE A 20 1 16 SPARE B 20 1 PHASEA KVA : 13.5 18 SPARE C 20 1 AMPS : 112.6 20 SPARE A 20 1 PHASEB KVA : 12.6 AMPS : 105.0 22 SPARE B 20 1 24 SPARE C 20 1 PHASECKVA : 14.2 26 SPARE A 20 1 AMPS : 118.3 28 SPARE B 20 1 - 30 SPARE C 20 1 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE B 20 1 KVA : 40.3 36 SPARE C 20 1 AMPS : 111.9 38 SPARE A 20 1 DEMAND LOAD 40 ISPARE B 1 KVA : 29.6 42 SPARE C L20 1 AMPS : 82.3 NOTES/REMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 10.0 REM ININGOVER 10KVA 50% = 3.7 H HEATING 100% _ M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% = 12.9 0 OTHER 1000A = 3.0 PANEL: L4B PROJECT NAME BECU TUKWILA PROJECT #: 15110 LOCATION: FLOOR4 FED FROM: PANELL4 NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 9 AM P R H M L K O TOTAL 2 1 REC- OFFICES 456, 457,459 A 20 1 1.1 1 1.1 PANEL AMPS : 225 2 `3 WORK STATIONS NE B 20 1 �- 0.9 0.9 FEEDER AMPS : 225 2 5 WORK STATIONS NE C 20 1 0.9 0.9 L - L VOLTS : 208 2 7 WORK STATIONS NE A 20 1 1.2 1.2 L- N VOLTS : 120 2 9 WORK STATIONS NE B 20 1 0.9 0.9 PHASE: 3 2 11 WORK STATIONS NE C 20 1 1.2 1.2 WIRE: 4 2 13 WORK STATIONS NE A 20 1 1.2 1.2 2 15 WORKSTATIONS NE, NW B 20 1 ` 1.2 1.2 2 17 WORK STATIONS NW C 20 1 1.2 1.2 2 19 WORKSTATIONS NORTH A 20 1 0.9 0.9 M.L.O. 2 21 WORKSTATIONS NORTH B 20 1 0.6 0.6 MAIN CB X 2 23 WORKSTATIONS NORTH C 20 1 FLUSH 2 25 WORKSTATIONS NORTH A 20 1 SURFACE X 2 27 REC CONF RM 449, PHONE RMS 416,417 B 1 20 1 0.7 0.7 ISO GND 2 29 FLATSCREEN REC CONF RM 449 CI 20 1 0.7 0.3 1.0 FEED-THRU 2 31 WORK STATIONS NW A 20 1 1.2 1.2 2 33 WORK STATIONS NW B 20 1 1.2 1.2 2 35 WORK STATIONS NN C 20 1 0.9 0.9 2 37 WORK STATIONS NW A 20 1 0.9 0.9 LOADSUMMARY 39 SPARE B 20 1 ( TOTAL, ALL SECTIONS) -41 SPARE C 20 1 REC KVA : 6.1 2 2 REC OONF RM 440, OFFICE 445 A 20 1 1.1 1.1 2 4 RECS - EAST BREAKOUT B 20 1 0.5 0.5 HEAT KVA 6 SPARE C 20 1 0.4 0.4 MOTOR KVA 2 8 REC SW OPEN OFFICE, W BREA KOUT A 20 1 LIGHTING KVA 2 10 WORK STATIONS NW B 20 1 0.9 0.9 KITCHEN KVA OTHER KVA : 24.6 2 12 WORK STATIONS NW C 20 1 1.2 1.2 2 14 WORK STATIONS NN A 20 1 1.2 1.2 2 16 WORK STATIONS MN B 20 1 0.9 0.9 PHASE A KVA : 10.6 2 18 WORKSTATIONS NW C 20 1 1.2 1.2 AMPS : 88.3 2 20 REC @, OFFICE DESKS 434,435 A 20 1 0.6 0.6 PHASE B KVA : 9.4 2 22 REC OFFICES 433,434,435,436 B 20 1 0.7 0.7 AMPS : 78.3 2 24 REC g, OFFICE DESKS 433,436 C 20 1 0.6 0.6 PHASE C KVA : 10.7 2 26 WORK STATIONS NW A 20 1 1.2 1.2 AMPS : 89.2 2 28 WORK STATIONS NW B 20 1 0.9 0.9 2 30 WORK STATIONS NN C 20 1 1.2 1.2 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE B 20 1 KVA : 30.7 36 SPARE C 20 1 AMPS : 85.2 38 SPARE A 20 1 DEMAND LOAD 40 SPARE 1131 2TDOE KVA : 30.7 2 42 RECS - NORTH CORRIDORS C 2 0.9 0.9 AMPS : 85.2 NOTESIREMARKS : EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED MND! DIVERSITY FACTORS1. AD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 6.1 REMAINING OVER10KVA 50% _ H HEATING 100% _ M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% _ 0 OTHER 100% = 24.6 PANEL: L4C (SECTION 1) PROJECT NAME: BEC U TUKWI LA PROJECT #: 15110 LOCATION: FLOOR4 FED FROM: PANEL L413 NOTE CKT NO. CIRCUIT NAME CBSIZE 8AM P LOAD(KVA) PANEL DESCRIPTION R H M L K O TOTAL 1 1 EXISTING REC RESTROOM SINKS A 20 1 0.4 0.4 PANEL AMPS : 225 1 3 EXISTING MENS RESTROOM HAND DRY ER B 20 1 1.0 1.0 FEEDERAMPS : 225 L- L VOLTS : 208 1 5 EXISTING WOMENS RESTROOM HAND DRYER C 20 1 1.0 1.0 1 7 EXISTING STROB F/A POWER SUPPLY A 20 1 0.5 0.5 L - N VOLTS : 120 1 9 EXISTING CORE RECEPTS WATER COOLER B 20 1 0.7 0.7 PHASE: 3 1 11 EXISTING EAST PERIMETER REC C 20 1 0.7 0.7 WRE : 4 1 13 EXISTING WEST PERIMETER REC A 20 1 0.7 0.7 1 15 EXISTING FAN ELECTRICAL RM B 20 1 0.3 0.3 M.L.O. 2 17 WORKSTATIONS NW C 20 1 0.6 0.6 2 19 WORKSTATIONS NW A 20 1 0.6 0.6 MAIN CB X 3 21 HEAT PUMP HP-401 B 30 2 2.0 2.0 FLUSH 3 23 --- C -- - 2.0 2.0 SURFACE X 25 SPARE A 20 1 ISO GND 27 SPARE B 20 1 FEED-THRU X ll 29 SPARE C 20 1 31 SPARE A 20 1 33 SPARE B 20 1 35 SPARE C1 20111 37 SPARE A 20 1 LOADSUMMARY 39 SPARE B 20 1 (TOTAL, ALL SECTIONS) 41 SPARE C 20 1 REC KVA : 4.6 2 2 WORK STATIONS SE A 20 1 1.2 1.2 2 4 WORK STATIONS SE B 20 1 0.9 0.9 HEAT KVA : 2.0 2 6 WORK STATIONS SE C 20 1 1.2 1.2 MOTOR KVA : 6.4 2 8 WORK STATIONS SE A 20 1 1.2 1.2 LIGHTING KVA 2 10 WORK STATIONS SE B 20 1 1.2 1.2 KITCHEN KVA OTHER KVA : 14.0 2 12 WORK STATIONS SE, BREAKOUT C 20 1 0.6 0.6 2 14 WORK STATIONS SE A 20 1 0.9 0.9 2 16 WORKSTATIONS SE B 20 1 0.9 0.9 PHASEA KVA : 9.0 2 18 WORKSTATIONS EAST C 20 1 0.9 0.9 AMPS : 75.0 2 20 WORKSTATIONS EAST A 20 1 0.9 0.9 PHASE B KVA : 9.7 2 22 WORKSTATIONS FAST B 20 1 0.9 0.9 AMPS : 80.8 2 24 WORK STATIONS EAST C 20 1 0.9 0.9 PHASE C KVA : 9.3 2 26 WORK STATIONS EAST A 20 1 0.9 0.9 AMPS : 77.5 2 28 WORK STATIONS EAST B 20 1 0.9 0.9 20 EXH FANS EF 4-01, 02 C 20 1 1.4 1.4 32 EXH FAN EF 4-03 A 20 1 0.7 0.7 CONNECTED LOAD 34 SPARE B 20 1 KVA : 27.0 36 SPARE C 20 1 AMPS : 74.9 38 SPARE A 20 1 DEMAND LOAD 40 1 COW REC HALLWAYS SW B 20 IC 1 0.9 0.9 KVA : 27.5 42 ISPARE 20 1 1 AMPS : 76.3 NOTES/REM ARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT M001RED BYTHIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKERAS INDICATED LOAD DESCRIPTION DEMAND R RECEPTACLES-TO1OKVA 100% = 4.6 REMAINING OVER 101<VA 50% _ H HEATING 100% = 2.0 M MOTORS 100% = 4.4 LM LARGEST MOTOR 125% = 2.5 L LIGHTING 125% _ K KITCHEN 65% _ O OTHER 100% = 14.0 PANEL: LC12 PROJECT NAME BECU TUKWILA PROJECT #: 15110 LOCATION FLOOR 4 FED FROM: PA NEL LC5 NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 0 AMPI P R H M L K 0 TOTAL 1 REG OFFICES 456, 457,459 A 20 1 0.9 0.9 PANEL AMPS : 100 3 REC GONF RM 449 B 20 1 0.2 0.2 FEEDER AMPS : 100 L- L VOLTS : 208 5 SPARE C 20 1 7 REC OONF RM 414 A 20 11 0.2 0.2 L - N VOLTS : 120 PHASE : 3 WIRE : 4 9 SPARE B 20 1 11 REC CONF RM 460 C 20 1 0.2 0.2 13 VIDEO REC CONF RM 460 A 20 1 0.3 0.3 15 WORKSTATIONS NE B 20 1 0.9 0.9 17 WORKSTATIONS NE C 20 1 0.9 0.9 19 WORKSTATIONS NW A 20 1 0.9 0.9 M.L.O. X 21 WORKSTATIONS NW B 20 1 0.9 0.9 MAIN CB 23 SPARE C 20 1 FLUSH 25 REC- SM CONF RM 440, OFFICE 445 A 20 1 0.2 0.5 0.7 SURFACE X 27 RECS - CAT LAB 438 B 20 1 1.2 1.2 ISO GND 29 RECS - OFFICES 435,436 C 20 1 0.6 0.6 FEED-THRU 31 PODIUM FLR REC- TRAINING 417 A 20 1 0.4 0.4 33 PODIUM FLR REC- TRAINING 417 B 20 1 0.4 0.4 35 SPARE C 20 1 37 SPARE A 20 1 LOADSUMMARY 39 SPARE B 20 1 ( TOTAL, ALL SECTIONS) 41 jSPARE C 20 1 REC KVA : 1.9 2 WORKSTATIONS SW A 20 1 0.9 0.9 4 WORKSTATIONS SW B 20 1 0.9 0.9 HEAT KVA 6 WORKSTATIONS SW C 20 1 0.9 0.9 MOTOR KVA 8 WORKSTATIONS SW A 20 1 0.6 0.6 LIGHTING KVA 10 WORKSTATIONS SW B 20 1 0.9 0.9 KITCHEN KVA 12 WORKSTATIONS SW C 20 1 0.6 0.6 OTHER KVA : 18.9 14 WORKSTATIONS SOUTH A 20 1 0.9 0.9 167 WORKSTATIONS SOUTH B 20 1 0.6 0.6 PHASEA KVA : 7.1 18 WORKSTATIONS SOUTH C 20 1 0.9 0.9 AMPS : 59.2 PHASE B KVA : 7.6 AMPS : 63.3 20 WORKSTATIONS SOUTH A 20 11. 0.6 0.6 22 WORKSTATIONS EAST B 20 Ill 0.9 0.9 24 WORKSTATIONS EAST C 20 Ill 0.9 0.9 PHASE C KVA : 6.1 26 REC ATM LAB 441 A 20 1 0.7 0.7 AMPS : 50.8 28 REC ATM LAB 441 B 20 1 0.7 0.7 30 REC ATM LA B 441 C 20 1 1.1 1.1 32 ISPARE A 20 1 CONNECTED LOAD 34 ISPARE B 20 1 KVA : 20.8 36 ISPARE C 20 1 AMPS : 57.7 38 SPARE A 20 1 DEMAND LOAD 40 SPARE IB 20 1 KVA : 20.8 42 SPARE C 20 1 AMPS : 57.7 NOTESIREMARKS : 1. LOAD 2. 3. DEMAND/ DIVERSITY FACTORS DESCRIPTION DEMAND R RECEPTACLES- TO 10KVA 100% = 1.9 REMAINING OVER 10KVA 60% _ H HEATING 100% _ M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% _ 0 OTHER 100% = 18.9 RECEIVE-0 CITY OF TUKWILA AUG 12 2015 PERMIT CENTER ■ Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 REVIEWED WITHC®MPLI NFPA 70 - NEC SEP 0 4 2015 City of -Tukwila BUILDING DIVISI®N Tenant Improvement for: BECU TUKWITA 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: 4TH FLR PANEL SCHEDULES Designed By: Drawn By: Project No: Date: RB MB 15110 08/05/2015 Sheet Number: f PANEL: H5 PROJECT NA ME BECU TUKVWA LA PROJECT#: 15110 LOCATION: FLOOR 5 FED FROM: 225A DISCONNECT NOTE CKT NO. CIRCUITNAME CBSIZE LOAD(KVA) PANEL DESCRIPTION OAMPP R H M L K O TOTAL 3 1 LTS-BNCLOSED OFFICEAND SUPPORT A 20 1 1.3 1.3 PANEL AMPS : 225 3 SPACE B FEEDER AMPS : 225 5 SPACE C L - L VOLTS : 480 - 1 7 9 11 - 13 SPACE SPACE - SPACE SPARE -� A 8 C A 20 13 ..... ............ .............. L - N VOLTS : 277 RHASE : 3 WIRE : 4 1 15 --- B -- - 1 17 --- C -- - 1 19 SPARE A 20 1 M.L.O. MA IN CB X 2 21 FPTU 506 B 20 1 3.0 0.7 3.7 2 23 FPTU 508 C 20 1 3.5 0.7 4.2 FLUSH 2 25 FPT(U509 A 20 1 2.5 0.7 3.2 SURFACE X 2 27 FPTU 510 B 20 11 3.0 0.7 3.7 ISO GND FEEU•THRU 2 29 FPTU 511 C 20 1 3.5 0.7 4.2 1 31 SPARE A 40 3 1 33 --- B -- 1 35 --- C -- - 2 37 FPTU 504, 505, 507 A 1 5.0 0.7 5.7 LOADSUMMARY 2 39 - - - B - - 5.0 0.7 5.7 1 ( TOTAL, ALL SECTIONS } 2 41 --- C -- 5.0 1.1 1 6.1 REC KVA 2 2 LTS-OPEN OFFICES A 20 1 3.6 3.6 2 4 LTS-OPEN OFFICES B 20 1 1.7 1.7 HEAT KVA : 69.7 6 SPARE C 20 1 MOTOR KVA 13.6 8 SPARE Al20 1 LIGHTING KVA : 6.6 10 SPARE B 20 1 KITCHEN KVA 12 SPARE C 20 1 OTHER KVA 14 SPARE A 20 1 1 16 SPARE B 20 1 V R-ASEA KVA : 29.1 18 SPARE C 20 1 AMPS : 105.1 20 SPARE A 20 1 PHASE B KVA : 31.1 22 FPTU 516 B 30 1 4.0 0.7 4.7 AMPS : 112.3 3 24 FPTU 518 C 30 1 4.0 0.7 4.7 PHASE C KVA : 29.7 3 26 FPTIJ519 A 30 11 1 3.0 0.7 1 3.7 AMPS : 107.2 2 28 30 32 SPARE SPARE FPTU515,517 - -- B 20 -_. C 20 A 30 1 ------- 1 3 - -- 3.7 1.1 4.8 CONNECTED LOAD 2 34 - - B - - 3.7 1.1 4.8 KVA 89.9 2 36 - - C - - 3.7 3.7 AMPS : 108.1 2 38 FPTU 512,513,514 A 40 3 5.7 1.1 6.8 DEMAND LOAD 2 40 --- B -- - 5.7 1.1 6.8 KVA 91.8 2 42 --- C --]]]]]] 5.7 1.1 6.8 AMPS : 110.4 NOTES/REMARKS: 1. EISTINGCIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDENEIN CIRCUIT BREAKER AS INDICATED DEMAND / DIVERSITY FACTORS LOAD DESCRIPTION DEVIAND R RECEPTACLES- TO 10KVA 100% _ RBVEANINGOVER 10KVA 50% _ H HEATING 100% = 69.7 M MOTORS 100% = 12.5 LM LARGESTMOTOR 125% = 1.4 L LIGHTING 125% = 8.3 K KITCHEN 65% _ O OTHER 100% _ PANEL: L5 (SECTION 1) PROJECT NAME BECU TUKVWALA PROJECT#: 15110 LOCATION: FLOOR 5 FED FROM: 150 KVA XFMR T6 NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 A P R H M L K 0 TOTAL 2 1 FLOOR BOX - BREA KOUT 506 A 20 1 0.4 0.4 PANE_ AMPS : 225 2 3 FLOOR BOX - BREA KOUT 506 B 20 1 0.4 0.4 FEEDER AMPS : 225 2 5 DEDICATED GFCI REC PANTRY COUNTER TOP C 20 1 1.2 1.2 L- L VOLTS : 208 2 7 GARBAGE DISPOSAL REC PANTRY A 20 1 1.2 1.2 L- N VOLTS : 120 2 9 DISHWASHER REC PANTRY B 20 1 1.2 1.2 R-LASE: 3 2 11 CONVENIENCE GFCI REC PANTRY COUNTERI C 20 1 0.5 0.5 WIRE : 4 2 13 DEDICATED GFCI REC PANTRY COUNTER TOP A 20 11 1.2 1.2 2 15 MICROWAVE REC PANTRY B 20 1 1.2 1.2 2 17 MICROWAVE REC PANTRY C 20 1 1.2 1.2 M.L.O . 2 19 FLOOR BOX CONF RM 513 A 20 1 0.4 0.4 IVA N CB X 2 21 REC CONF RM 513 B 20 1 0.6 _ 0.6 FLUSH 2 23 FLATSCREEN REC CONF RM 513 C 20 1 0.3 0.3 SURFACE X 2 25 REC WELLNESS 512, STOR 511, SCHEDULER A 20 1 1.1 1.1 ISO GND 2 27 FLOOR BOX RED CONF RM 510 B 20 1 0.4 0.4 FEB}THRU X 2 29 FLAT SCREEN REC CONF RM 510 C 20 1 0.3 0.3 2 31 33 REC PANTRY U/C REFERS? FLOOR BOX REC PANTRY & COLUMN A 20 B 20 1 1 0.5 -- - 1.0 1.0 0.5 2 35 CONV REC SW HALL, BREA KOUT506 C 20 1 1.1 1.1 37 SPARE A 20 1 LOADSUMMARY 39 SPARE B 20 1 ( TOTAL, ALL SECTIONS ) 41 SPARE C 20 1 REC KVA : 24.1 HEAT KVA 5.0 2 2 2 4 WORK STATIONS NE WORK STATIONS NE A 20 B 20 1 1 0.6 0.6 0.6 0.6 2 6 WORK STATIONS NE C 20 1 0.8 0.8 MOTOR KVA : 2.7 2 8 REC CONF RM 503 A 20 1 0.6 0.6 LIGHTING KVA : 1.1 2 10 REC CONF RM 503 B 20 1 0.4 0.4 KITCHEN KVA 12.0 2 12 RECS - BREAKOUT 506 Cl20 Ill 0.7 0.7 OTHER KVA 32.1 2 14 WORK STATIONS NE A 20 1 0.8 1 0.8 2 1 16 IWORK STATIONS NE B 20 1 0.6 0.6 RMSEA KVA 23.6 AMPS : 196.7 2 18 WORK STATIONS NE C 20 1 0.6 0.6 2 20 WORK STATIONS NE A 20 1 0.8 0.8 R-ASE B KVA 22.9 2 22 WORK STATIONS NE B 20 1 0.6 0.6 AMPS : 190.8 2 24 WORK STATIONS NE C 2011 0.6 0.6 R-IASEC KVA : 27.6 2 26 WORK STATIONS NE A 20 1 0.6 0.6 AMPS: 230.0 2 28 IWORK STATIONS NE B 20 1 0.6 0.6 2 30 CONV RECHALLWAYS NE C 20 1 1.1 1.1 2 32 REC TEAMFM561 A 20 1 0.7 0.7 CONNECTED LOAD 2 34 FLATSCREEN REC TEAM RM 561 B 20 1 0.3 0.3 KVA 77.0 2 36 FLOOR BOX REC TEAM RM 561 C 20 11 0.4 1 0.4 AMPS : 213.7 1 38 NEWTVSS A 20 3 0.2 0.2 DEMAND LOAD 1 40 - - - B - - 0.2 0.2 KVA 66.0 1 42 1 - - - C - - 0.2 1 0.2 1 0.4 AMPS : 183.3 NOT ESIREr1ARKS : 1. IXISTINGCIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NBIVCIRCUIT BRFAKERAS INDICATED LOAD DESCRIPTION DEVEAND R RECEPTACLES - TO IOKVA 1000/0 = 10.0 REMAINING OVER 10KVA 50% = 7.1 H HEATING 1000/0 = 5.0 M MOTORS 100% = 2.7 LM LARGESTMOTOR 125% _ L LIGHTING 125% = 1.4 K KITCHEN 65% = 7.8 0 OTHER 1000/0 = 32.1 PANEL: LC1 (SECTION 1) PROJECT NAME BECU TUKW LA PROJECT #: 15110 LOCATION: FLOOR 5 FED FROM: MANT. BYPASS NOTE CKT NO. CIRCUIT NAME CB SIZE LOAD (KVA) PANEL DESCRIPTION 8 AMP P R H M L K O TOTAL 2 2 1 3 WORKSTATIONS NORTH VWIORKSTATIONS NOFRTH A 20 B 20 1 1 0.9 0.9 0.9 0.9 PANELAMPS : 400 F®EERAMPS : 400 2 5 WORKSTATIONS NORTH C 20 1 1.2 1.2 L - L VOLTS : 208 2 7 IWORKSTATIONS NORTH A 20 1 0.9 0.9 L- N VOLTS : 120 2 9 WORKSTATIONS NORTH B 20 1 1 0.9 0.9 PHASE: 3 2 11 WORKSTATIONS NORTH C 20 1 1.2 1.2 WIRE: 4 2 13 WORKSTATIONS NORTH _ A 20 1 1.2 1.2 2 15 WORKSTATIONS NORTH B 20 1 1.2 1.2 2 17 WORKSTATIONS NORTH C 20 1 y 0.9 0.9 ML.O. 2 19 WORKSTATIONS NORTH A 20 1 0.9 0.9 MAIN CB X 2 21 FLR RED- TEAM RM 561 B 20 1 0.2 0.2 FLUSH 2 23 FLR REC- CONE RM 504 C 20 1 0.2 0.2 1 SURFACE X 2 25 WORKSTATIONS SW A 20 1 0.9 0.9 ISO GND 2 27 WORKSTATIONS SW B 20 1 0.9 0.9 FE$THRU X 2 29 WORKSTATIONS SW C 20 1 0.9 0.9 2 31 WORKSTATIONS SW A 20 1 0.9 0.9 2 33 RE GS - OFFICES 532,533,534,535 B 20 1 1.2 1.2 35 SPA RE Cl20 11 1 3T PANEL LC9 A 10013 LOADSUMMARY 1 39 - - - B - - ( TOTAL. ALL, SECTIONS) 1 41 --- C - - REC KVA : 12.4 HEAT KVA 2 2 FLR, VIDEO REC- CCNF RM 513 A 20 1 0.4 1 0.4 2 1 4 WORKSTATIONS NE B 20 11 1 1 0.9 0.9 2 6 WORKSTATIONS NE C 20 1 0.9 0.9 MOTOR KVA 2 8 WORKSTATIONS NE A 20 1 0.9 0.9 LIGHTING KVA 2 10 VvoRKSTATIONS NE 8 20 1 0.0 0.9 KITCHEN KVA : 5.5 2 12 WORKSTATIONS NE C 20 1 0.9 0.9 OTHER INA : 105.3 2 14 WORKSTATIONS NE A 20 1 0.9 0.9 2 16 WORKSTATIONS SOUTH B 20 1 1.2 1.2 R-IASEA KVA : 42.9 2 18 VIIORKSTATIONS SOUTH C 20 1 0.9 0.9 AIVIPS: 357.5 2 20 WORKSTATIONS SOUTH A 20 1 0.9 0.9 R-IASE B KVA : 43.7 2 22 WORKSTATIONS SOUTH B 20 1 1 0.9 0.9 AMPS: 364.2 2 24 WORKSTATIONS SOUTH C 20 1 0.6 0.6 R-ASEC KVA : 36.6 2 26 WORKSTATIONS SOUTH A 20 1 0.9 0.9 AMPS: 305.0 2 28 WORKSTATIONS SOUTH B 20 1 0.9 0.9 2 30 WORKSTATIONS SW C 20 1 0.9 0.9 2 32 WORKSTATIONS SW A 20111 0.9 1 0.9 CONNECTED LOAD 2 34 WORKSTATIONS SW B 20 1 0.9 0.9 KVA : 123.2 2 36 WORKSTATIONS SW C 20 1 0.9 0.9 AMPS : 342.0 38 SPARE A 20 1 - DEVIAND LOAD 40 ISPARE B 20 1 KVA : 120.1 42 ISPARE Cl20 1 AMPS : 333.3 NOTESMEIARKS : 1. IXISTINGCIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 1000/0 = 10.0 RB 91NNG OVER 10KVA 50% = 1.2 H HEATING 1000/0 _ M MOTORS 1000/0 _ LM LA RGEST MOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% = 3.6 O OTHER 1000/0 = 105.3 PANEL: L513 (SECTION 2) PROJECT NAME BECU TUKVII LA PROJECT #: 15110 LOCATION: FLOOR 5 FED FROM: PANEL L5 NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 AMP PI R I M I L K O 1 TOTAL 2 1 COUNTER RECS - COPY 525 A 20 1 0.4 0.4 PANEL AMPS : 225 2 3 COUNTER RECS - COPY 525 B 20 1 0.4 0.4 FEEDER AMPS : 225 2 5 REC CONF RM 528 C 20 1 0.6 0.6 L- L VOLTS : 208 2 7 FLATSCREEN REC CONF RM 528 - A 20 1 0.3 0.3 L - N V OLTS : 120 2 9 REC CONF RM 527 B 20 1 0.6 0.6 PHASE: 3 2 11 FLATSCREEN REC CONF RM 527 C 20 1 0.3 0.3 WIRE : 4 2 13 REC CONF RM 517 A 20 1 0.5 0.5 2 15 FLATSCREEN REC OONF 517 B 20 1 2 17 FLOOR BOX RED CONF RM 517 C 20 1 0.4 0.4 M.L.O. X 2 2 19 21 REC CONF RM 521, PHONE RMS 519,520 FLOOR BOX REC CONF RM 521 A 20 B 20 1 0.9 1 0.4 0.9 0.4 IV A N CB FLUSH 2 23 FLATSCREEN REC CONF RM 521 C 20 1 0.3 0.3 SURFACE X 25 SPARE A 20 1 ISO GND 27 SPARE B 20 1 0.4 0.4 FEED•THRU X 29 SPARE C 20 1 0.4 1 0.4 2 31 WORK STATIONS SE A 20 1 0.9 0.9 2 33 WORK STATIONS SE B 20 1 0.9 0.9 2 35 REC HALLWAY EAST C 20 1 0.6 0.6 37 SPARE A 20 1 LOAD SUMMARY 39 SPARE B 20 1 (TOTAL, ALL SECTIONS) 41 SPARE C 20 1 REC KVA : 14.8 2 2 IWORKSTAT7ICNSNW A 20 1 0.9 0.9 2 4 WORKSTATIONS NW B 20 1 0.9 0.9 HEAT KVA : 5.0 2 6 WORK STATIONS NW C 20 1 0.4 0.6 1.0 MOTOR KVA : 2.7 2 8 WORKSTATIONSNW A 20 1 - 0.9 0.9 LIGHTNGKVA : 1.1 2 10 WORK STATIONS NW B 20 1 0.9 0.9 KITCHEN KVA : 3.0 2 12 WORK STATIONS NW C 20 1 0.9 0.9 OTHER KVA : 24.0 2 14 WORKSTATIONSNW A 20 1 0.9 1 0.9 2 16 WORKSTATIONSMN B 20 1 0.9 0.9 FHASEA KVA 14.0 2 18 WORK STATIONS NW C 20 11 0.9 0.9 AMPS : 116.7 2 20 WORK STATIONS NW A 20 11 1.2 1.2 PHASE B KVA 15.3 2 22 WORK STATIONS NW B 20 1 0.9 0.9 AMPS : 127.5 2 24 WORK STATIONS NW C 20 1 0.9 0.9 R-ASE C KVA 18.4 2 2 26 28 WORKSTATICNSNW WORK STATIC NS NW A 20 B 20 1 1 0.9 0.9 0.9 0.9 AMPS : 153.3 2 30 WORK STATIONS NW C 20 1 0.9 0.9 2 32 WORK STATIONS NW A 1 20 1 0.3 0.3 CONNECTED LOAD 2 34 WORK STATIONS NW B 20 1 0.6 0.6 KVA : 50.6 2 36 REC OFFICES 532,533 C 20 1 0.4 0.6 1.0 AMPS : 140.5 2 38 WORK STATIONS SW A 20 1 0.6 0.6 DEMANDLOAD 2 40 1 WORK STATIONS SW B 20 1 0.9 0.9 KVA 47.4 2 42 REC HALLWAYS WEST C 20 1 1.1 1.1 AMPS : 131.6 NOTESIREMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER ASINDICATED LOAD DESCRIPTION DEMAND R RECEPTACLES- TO 10KVA 100% = 10.0 RSVIAINNGOVER10KVA 50% = 2.4 H HEATING 100% = 5.0 M MOTORS 100% = 2.7 LM LARGESTMOTOR 125% _ L LIGHTING 125% = 1.4 K KITCHEN 65% = 2.0 O OTHER 100% = 24.0 PANEL: LC2 (SECTION 2) PROJECT NAME: BECU TUKWILA PROJECT;*. 15110 LOCATION: FLOOR 5 FED FROM: PANEL LC1 CKT NO. CIRCUIT NAME CBSIZE LOAD (KVA) PANEL DESCRIPTION 8 AIVIP P R H M L K O TOTAL [NOTE 2 2 1 3 RECS - CONF RM517 RECS- CONF RM527,528 A 20 B 20 1 0.4 1 0.4 0.4 0.4 PANEL AMPS: 400 FELDERANE'S : 400 5 SPARE C 20 1 L- LVOLTS : 208 7 SPARE A 20 1 L- NVOLTS: 120 9 SPARE B 20 1 1 1 1 PHASE: 3 11 SPARE C 20 1 WIRE : 4 13 SPA RE - A 20 1 15 SPA RE B 20 1 17 SPARE C 20 1 M.L.O. X 19 SPARE A 20 1 MA IN CB 21 SPARE B 20 1 1 1 1 FLUSH 23 SPARE C 20 1 SURFACE X 25 SPARE A 20 1 ISO GND 27 SPARE B 20 1 FEED-THRU X 29 SPARE C 20 1 31 SPARE A 20 1 33 SPARE B 20 1 35 SPARE C 20 1 37 SPARE - A 20 1 LOADSUMMARY 39 SPARE - -� B 20 1 (TOTAL. ALL SECTIONS) 41 SPARE C 20 1 REC KVA : 11.6 2 SPARE A 20 1 4 SPARE B 20 1 HEAT KVA 6 SPARE C ZO 1 MOTOR KVA 8 SPARE A 20 1 LIGHTING KVA 10 SPARE B 20 1 K rr-HEN KVA 5.5 12 SPARE C 20 1 OTHER KVA : 75.0 14 SPA RE A 20 1 16 SPARE B 20 1 R-ASEA KVA : 32.3 _ 18 SPARE C 20 1 AMPS : 269.2 20 SPARE A 20 1 PHASE KVA : 32.7 22 SPARE B 20 1 AIVIPS : 272.5 24 SPARE C 20 1 R{ASEC KVA : 27.1 26 SPARE A 20 1 AMPS : 225.8 28 SPARE B 20 1 30 SPARE C 20 1 32 SPARE A 20 11 1 CONNECTED LOAD 34 SPARE B 20 11 KVA : 92.1 36 SPARE C 20 1 AIVIPS : 255.6 38 SPARE A 20 1 DBVIAND LOAD _ 40 SPARE B 20 1 KVA : 89.4 42 SPARE C 20 1 AIVIPS : 248.1 NOTESIREMARKS: 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 1000/0 = 10.0 REMAINING OVER 10KVA 500/0 = 0.8 H HEATING 1000/0 _ M MOTORS 100% _ LM LA RGEST MOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% = 3.6 0 OTHER 1000/0 = 75.0 PANEL: LC5 (SECTION 1) PROJECT NAME BECUTUKWLA PROJECTA 15110 LOCATION: FLOOR 5 FED FROM: PANEL LC4 NOTE CKT NO. CIRCUIT NAME CB SIZE LOAD(KVA) PANEL DESCRIPTION 8 AM P R H M L K O TOTAL 1 3 SPARE SPARE _ A 20 B 20 1 1 - - PANELAMPS : 225 FEEDERAMPS : 225 5 SPARE C 20 1 L- L VOLTS : 208 7 SPARE A 20 1 L-NVOLTS : 120 9 SPARE B 20 1 1 1 1 PHASE: 3 11 SPARE i CI 20 1 WIRE : 4 13 SPARE A 20 1 15 SPARE B 20 1 17 SPARE C 20 1 M.L.O. 19 SPARE A 20 1 IVAINCB X 21 SPARE B 20 1 FLUSH 23 SPARE C 20 1 SURFACE _X 25 SPARE A 20 1 ISO GND 27 SPARE B 20 1 FEED-THRU X 29 SPARE C 20 1 31 SPARE A 20 1 33 SPARE B 20 1 35 SPARE C 1 2011 1 37 PANEL LC12 A 100 3 1.1 6.0 7.1 LOAD SUMMARY 39 - - - B - - 0.6 7.0 7.6 (TOTAL, ALL SECTIONS) 41 --- C - - 0.2 5.9 6.1 RED KVA : 6.5 HEAT KVA 2 SPARE A 20 1 4 SPARE B 20 1 6 SPARE C 20 1 MOTOR KVA 8 SPARE A 20 1 LIGHTING KVA 10 SPARE B 20 1 KITCHEN KVA : 5.5 12 SPARE C 20 1 OTHER KVA : 58.2 14 SPARE A 20 1 16 1 SPARE B 20111 1 1 RHASEA KVA : 24.8 18 SPARE C 20111 AMPS : 206.7 20 SPARE A 20111 RHASEBKVA : 24.8 22 SPARE B 20 11 AMPS : 206.7 24 SPARE C 20 11 RHASECKVA : 20.6 26 SPARE A 20 1 AMPS : 171.7 28 SPARE �i B 20 1 30 SPARE C 20 1 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE B 20 1 KVA : 70.2 36 SPARE _CI 20 1 AMPS : 194.9 38 SPARE A 20 1 DEMAND LOAD 40 SPARE B 20 1 KVA : 68.3 42 SPARE C1 20 1 AMPS : 189.5 NOTES/REMARKS: 1. PROVIDE NEW CIRCUIT BREAKER AS SHOWN 2. 3. DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 1000A = 6.5 R6MANING OVER 10KVA 50% _ H HEATING 100% _ M MOTORS 1000/0 = LM LARGESTMOTOR 125% _ L LIGHTING 125% _ K KITCHEN 650/0 = 3.6 0 OTHER 100% - 58.2 PANEL: L5C (SECTION 3) PROJECT NAME BECU TUKW LA PROJECTA. 15110 LOCATION: FLOOR 5 FED FROM: PANEL 1_513 NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 WqTPF-R-7 H M L K O TOTAL 2 1 LTS-OPEN OFFICE A 20 11 0.3 0.3 PANELAMPS : 225 2 3 LTS-OPEN OFFICE B 20 1 0.3 0.3 FEEDERAMPS : 225 2 5 LTS-OPEN OFFICE C 20 1 0.5 0.5 L- L VOLTS : 208 2 7 RECS - OFF 534, BREAKOUT 535, OPEN OFF A 20 1 1.1 1.1 1 L - N V OLTS : 120 2 9 RECS - OFF 533, 534, OPEN OFFICE B 20 1 1.1 1.1 PHASE: 3 2 11 EXH FANS EF5-01, 02 CI 20 11 11.4 1.4 WIRE : 4 2 13 EXH FAN EF5-04 Al20 1 0.7 0.7 15 SPARE B 20 1 17 SPARE C 20 1 ML.O. X 19 21 SPA RE SPARE A 20 B 20 1 1 .......... MA IN CB FLUSH 23 SPARE C 20 1 SURFACE X 25 SPARE A 20 1 ISO CND 27 SPARE BI 20 1 FEED-THRU X 29 SPARE C 20 1 31 SPARE A 20 1 33 SPARE B 20 1 35 SPARE C 20 1 37 SPARE A 20 1 LOADSUMMARY 39 SPARE B 20 1 (TOTAL, ALL SECTIONS) 41 ISPARE C 20111 RED KVA : 7.3 2 2 WORK STATIONS SE A 20 1 0.4 0.4 2 4 WORK STATIONS SE B 20 1 0.4 0.4 HEAT KVA : 5.0 2 6 WORK STATIONS SE C 20 1 0.4 0.4 MOTOR KVA : 2.7 2 8 WORKSTATIONSSE T A 20 1 0.4 0.4 LIGHTING KVA : 1.1 2 10 WORKSTATIONSSE B 20 1 0.4 0.4 KITCHEN KVA : 3.0 2 1 12 IWORK STATIONS SE C 20 1 1 1.2 1.2 OTHER KVA : 4.5 2 14 WORK STATIONS SE A 2D 1 1.2 1.2 2 16 WORK STATIONS SE B 20 1 1 0.9 1 0.9 R-ASEA KVA : 5.3 2 18 WORKSTATIONSSE C 20 1 1.2 1.2 AMPS: 44.2 2 20 WORK STATIONS EAST A 20 1 0.6 0.6 PHASE B KVA : 6.3 2 22 WORKSTATIONS EAST, BREAKOUT B 20 1 0.9 0.9 AMPS : 52.5 2 24 WORK STATIONS EAST C 20 1 0.6 0.6 RHASECKVA : 9.1 2 26 28 WORKSTATIONS EAST SPARE A 20 B 20 1 0.6 1 0.6 AMPS : 75.8 30 SPARE C 20 1 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE B 20 1 KVA : 23.6 36 SPARE C 20 1 AMPS: 65.5 38 SPARE A 20 1 DENIAND LOAD 40 SPARE B 20 1 KVA : 23.2 42 SPARE C 20 1 AMPS : 64.3 NOTES/REVIARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED LOAD DESCRIPTION DEMAND R RECEPTACLES- TO 10KVA 1000/0 = 7.3 RE IVAINNG OVER 10KVA 500/0 _ H HEATING 1000/0 = 5.0 M MOTORS 1000/0 = 1.3 LM LA RGEST MOTOR 125% = 1.8 L LIGHTING 125% = 1.4 K KITCHEN 65% = 2.0 O OTHER 100% = 4.5 PANEL: LC3 (SECTION 3) PROJECT NAME BECU TUKVMLA PROJECT #: 15110 LOCATION: FLOOR 5 FED FROM: PANEL LC2 NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 AMI PI R H M L K O TOTAL _---...--- 1 3 SPARE -- -- -- - -----. SPARE A 20 B 20 1 1 PANE -AMPS : 400 FEVER AMPS : 400 5 SPARE C 20 1 L- LVOLTS : 208 7 SPARE A 20 1 L-NVOLTS : 120 9 SPARE B 20 1 PHASE : 3 11 SPARE C ZO 1 WIRE : 4 13 SPARE A 20 1 15 SPARE B 20 1 17 SPARE C 20 1 M.L.O. X 19 SPARE A 20 1 MAN CB 21 SPARE B 20 1 FLUSH 23 SPARE C 20 1 SURFACE X 25 SPARE A 20 1 ISO GND 27 SPARE B 20 1 FEED-THRU I X 29 SPARE C 20 1 31 SPARE A 20 1 33 SPARE B 20 1 35 SPARE C 20 1 37 SPARE A 20 1 LOADSUMMARY 39 SPARE B 20 1 (TOTAL ALL. SECTIONS) 41 SPARE C 20 1 REC KVA : 10.8 2 SPARE A 20 1 4 SPARE B 20 1 HEAT KVA 6 SPARE C 20 1 MOTOR KVA 8 SPARE A 20 1 LIGHTING KVA 10 1 SPARE B 20 1 KITCHEN KVA 5.5 12 SPARE C 20 1 OTHER KVA 75.0 14 SPARE A 20 1 16 SPARE B 20 1 PHASEA KVA 31.9 18 SPARE C 20 1 AMPS : 265.8 20 SPARE A 20 1 PHASE B KVA 32.3 22 SPARE B 20 1 AMPS : 269.2 24 SPARE C 20 1 PHASE C KVA 27.1 26 SPARE A 20 1 AMPS : 225.8 28 SPARE B 20 1 30 SPARE C 20 1 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE B 20 1 _ KVA 91.3 36 ISPARE C 20 11 1 AMPS : 253.4 38 SPARE A 20 1 DEMAND LOAD 40 SPARE B 20 1 KVA : 89.0 42 SPARE C 20 1 AMPS : 247.0 NOTESIRBMARKS : 1. 2. 3. DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES- TO 10KVA 100% = 10.0 REMAINING OVER 10KVA 50% = 0.4 H HEATING 100% _ M MOTORS 100% _ LM LARGESTMOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% = 3.6 O OTHER 100% = 75.0 PANEL: LC7 (SECTION 2) PROJECT NAME BECU TUKVMLA PROJECTM 15110 LOCATION: FLOOR 5 FED FROM PANEL LC5 NOTE CKT� NO. CIRCUITNAM E CBSIZE LOAD(KVA) PAIJEL DESCRIPTION 8 AM P R H M L K O TOTAL 1 3 SPARE SPARE - A 20 B 20 1 1 - PANE -AMPS : 225 FEEDERAMPS : 225 5 SPARE C 20 1 L- L VOLTS : 208 7 SPARE A 20 1 L- NVOLTS : 120 9 SPARE BI 20 1 PHASE: 3 11 SPARE C1 20 1 WIRE : 4 13 SPARE Al20 11 15 SPARE B 2011 17 SPARE _ C 20 1 M.L.O. X 19 SPARE A 20 1 IVANCB 21 SPARE B 20 1 FLUSH 23 SPARE C 20 1 SURFACE X 25 SPARE - - A 20 1 ISO GND 27 SPA RE B 2011 FEED-THRU X 29 SPARE C 20 11 31 SPARE A 20 1 33 1 SPARE B 20 1 35 SPARE C 20 1 1 37 PANEL LC- I3(6THFLOOR) A 100 3 0.8 2.2 1 6.0 1 9.0 LOADSUMMARY 39 --- B -- - 0.8 1.8 5.1 7.7 (TOTAL, ALL SECTIONS) 41 --- Cl-- - 1.2 1.5 3.9 6.6 REC KVA : 4.6 1 2 PANEL LG11 (3RD FLOOR) A 100 3 0.9 7.8 8.7 4 --- B -- - 0.5 9.0 9.5 HEAT KVA 6 - - - C - - 0.4 7.5 7.9 MOTOR KVA 8 SPARE A 20 1 LIGHTING KVA 10 SPARE B 20 1 KITCHEN KVA : 5.5 12 SPARE CI 20 1 OTHER KVA : 39.3 14 SPARE A 20 11 16 SPARE B 20 1 RHASEA KVA : 17.7 18 SPARE C 20 1 AMPS : 147.5 20 SPARE A 20 1 R-ASEBKVA : 17.2 22 SPARE B 20 1 AMPS : 143.3 PHASE C KVA : 14.5 AMPS : 120.8 24 SPARE C 20 1 26 SPARE A 20 111 1 1 28 SPARE B 20 1 30 SPARE C 20 1 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE B 20 1 KVA 49.4 36 SPARE C 20 1 AMPS : 137.1 38 SPARE AI 20 1 DEVIANDLOAD 40 SPARE B 20 1 KVA : 47.5 42 SPARE C 20 1 4-1AMPS : 131.8 NOTESIREMARKS : 1. PROVIDE NESNCIRCUIT BREAKER AS SHOWN 2. 3. DEM AND / DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 4.6 RBVIANING OVER 10KVA 50% _ H HEATING 100% _ M MOTORS 100% _ LM LARGESTMOTOR 125% _ L LIG1iTNG 125% _ K KITCHEN 65% = 3.6 0 OTHER 100% = 39.3 PANEL: L5D (SECTION 4) PROJECTNAME BECUTUKWLA PROJECTA 15110 LOCATION: FLOOR 5 FED FROM: PANEL L5C NOTE CKT NO. CIRCUITNAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 ANIJ PI R H M L K 1 O TOTAL 1 1 1 3 EXISTING REC SERVER CONFIG RM EXISTING REC SERV ER OONFIG RM A 20 B 20 1 1 1.0 1.0 1.0 1.0 PANEL AMPS: 225 FEEDER AMPS : 225 1 5 EXISTING REC SERVER OONFIG RM C 20 1 1.0 1.0 L - L VOLTS : 208 7 SPARE A 20 1 L-NVOLTS: 120 9 SPARE B 20 1 PHASE: 3 11 SPARE C 20 1 WIRE : 4 13 SPARE A 20 1 15 SPARE B 20 1 17 SPARE C 20 1 M.L.O. X 1 19 EXISTING BATHROOM REC A 20 1 0.4 0.4 MAIN CB 1 21 MENS BATHROOM HAND DRYER B 20 Ill 1.0 1 1.0 FLUSH 1 23 WOMBNS BATHROOM HANND DRYER C 20 1 1.0 1.0 SURFACE X 25 SPARE A 20 1 ISO GND 27 SPARE B 20 1 1 1 FE> D-THRU 29 SPARE C 20 1 31 SPARE A 20 1 33 SPARE B1 20 1 35 SPARE C 20 1 37 SPARE A 20 1 LOADSUMMARY 1 39 EXISTING EFL 13 ELM RM B 20 1 - 0.3 (TOTAL, ALL SECTIONS) 1 41 EXISTING EFL14 ELEC RM C 20 1 0.3 0.3 RED KVA : 0.4 HEAT KVA : 5.0 2 SPARE A 20 1 4 SPARE B 20 1 6 SPARE C 20 1 MOTOR KVA : 0.6 8 SPARE A 20 11 LIGHTING KVA 10 SPARE B 20 1 KITCHEN KVA : 3.0 _ 12 SPARE C 20 1 OTHER KVA 14 SPA RE A 20 1 16 SPARE B 20 1 R-IASEA KVA 1 18 EXISTING HEAT RUMP SW NEA R CORE? C 20 ? 1.5 1.5 AMPS 1 20 EXISTING HEAT RUMP SW NEA R CORE? A 20 ? 11 1.5 1.5 1 RASE B KVA : 2.3 22 SPARE B 20 1 AMPS : 19.2 24 SPARE C 20 1 FHASECKVA : 3.8 26 SPARE A 20 1 AMPS 28 SPARE B 20 1 30 SPARE C 20 1 32 SPARE A 20 11, CONNECTED LOAD _ 34 SPARE B 20 1 KVA : 9.0 36 SPARE C 20 1 AMPS : 25.0 38 SPARE A 20 1 - DBVl4ND LOAD 4D SPARE IB 20 1 KVA : 8.0 42 SPARE C 20 1 AMPS: 22.3 NOTES(REMARKS: 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDENEW CIRCUIT BREAKER AS INDICATED DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEIVIAND R RECFFTACLES- TO 1DKVA 1000/0 = 0.4 REVIAINNG OVER 10KVA 500/0 _ H HEATING 1000/0 = 5.0 M MOTORS 100% = 0.3 LM LARGESTMOTOR 125% = 0.4 L LIGHTING 125% _ K KITCHEN 65% = 2.0 O OTHER 1000/0 _ PANEL: LC4 (SECTION 4) PROJECT NAME BECU TUKIMLA PROJECT #: 15110 LOCATION: FLOOR 5 FED FROM: PANEL LC3 NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 AM P R H M L K O TOTAL 1 3 SPARE SPARE A 20 B 20 1 1 PANEL AMPS : 400 FEEDER AM : 400 5 SPARE C 20 1 L- LVOLTS: 208 7 SPARE A 20 1 L- N VOLTS : 120 9 SPARE B 20 1 PHASE : 3 11 SPARE C 20 1 WIRE : 4 13 SPARE A 20 1 15 SPARE B 20 1 _ 17 SPARE C 20 1 M.L.O. X 19 SPARE A 20 1 MAN CB 21 SPARE B 20 1 FLUSH 23 SPARE C 20 1 SURFACE X W 25 SPARE A 20 1 ISO GND 27 SPA RE B 20 1 FEED•THRU 29 SPA RE C 20 1 31 SPARE A 20 1 33 SPA RE B 2011 35 SPARE C 20 1 37 PANEL LC5 - A 225 3 2.8 _ 2.2 19.8 24.8 LOADSUMMARY 39 --- B -- - 1.9 1.8 21.1 24.8 (TOTAL, ALL SECTIONS) - 41 --- C -- - 1.8 1.5 17.3 20.6 2 PANEL LC8 A 225 3 1.4 5.7 7.1 REC KVA 10.8 4 - - - B - - - 1.8 5.7 7.5 HEAT KVA 6 - - - C - - - 1.1 5.4 6.5 MOTOR KVA 8 SPARE A 20 1 LIGHTING KVA 10 SPARE B 20 1 KITCHEN KVA 5.5 12 SPARE C 20 1 OTHER KVA 75.0 14 SPARE A 20 1 16 SPARE B 20 1 PI-ASEA KVA 31.9 18 SPARE C 20 1 AMPS : 265.8 20 SPARE A 20 1 PHA SEBKVA 32.3 22 SPARE B 20 1 AMPS : 269.2 24 SPARE C 20 1 PHASECKVA 27.1 26 SPARE A 20 1 AMPS : 225.8 28 SPARE B 20 1 30 SPARE - C 20 1 32 SPARE A 20 1 CONNECTED LOAD - 34 SPARE B 20 1 KVA 91.3 36 SPARE C 20 1 _ AMPS : 253.4 _ 38 SPARE A 20 1 DEMAND LOAD 40 SPARE B 20 1 _ KVA 89.0 42 ISPARE C 20 1 AMPS : 247.0 NOTESMEMARKS: 1. 2. 3. DEUTANDI DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 1 OKVA 100% = 10.0 REIVANING OVER 10KVA 50% = 0.4 H HEATNG 100% _ M MOTORS 100% _ LM LARGESTMOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% = 3.6 0 OTHER 100% = 75.0 PANEL: LC9 PROJECT NAME BECU TUKVMLA PROJECTM 15110 LOCATION: FLOOR 5 FED FROM: PANEL LC1 NOTE CKT NO. CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 A P R H M L K O TOTAL 1 _3 SPARE SPARE A 20 B 20 1 1 PANEL AMPS : 100 FEEDER AMPS : 100 5 SPARE C 20 1 L- LVOLTS: 480 7 SPARE A 20 1 L- NVOLTS : 277 9 SPARE B 20 1 1 1 PHASE : 3 11 SPARE C 20 1 WIRE : 4 13 SPARE A 20 1 15 SPARE B 20 1 17 SPA RE C 20 1 19 SPARE A 20 Ill I M.L.O. 21 SPARE B 20 1 MAN CB X 23 SPARE C 20 1 FLUSH - 25 SPARE A 20 1 SURFACE X 27 SPARE B 20 1 ISO GND 29 SPARE C 20 1 FEED-THRU 31 SPARE Al20 1 33 SPARE B 20 1 35 SPARE C 20 1 37 SPARE A 20 1 - LOADSUMMARY 39 SPARE B 20 1 ( TOTAL, ALL SECTIONS ) 41 SPARE C 20 1 1 REC KVA 2 SPARE A 20 1 4 SPARE B 20 1 HEAT KVA 6 SPARE C 20 1 _ MOTOR KVA 8 SPARE A 20 1 LIGHTING KVA 10 SPARE B 20 1 KITCHEN KVA 12 SPARE C 20 1 OTHER KVA 14 SPARE A 20 11 16 SPARE B 20 1 FHASEA KVA 18 SPARE C 20 1 AMPS 20 ISPARE A 20 1 PHASEB KVA 22 SPARE B 20 1 AIViPS: 24 SPARE C 20 1 RiASEC KVA 26 SPARE Al20 1 AMPS 28 SPARE B 20 1 CONNECTED LOAD 30 S t 20 1 32 SPARE A 401 _)0f7 34 SPARE B 20 1 KVA AMPS 36 SPARE C 20 1 _I 38 SPARE A 20 1 DBVIANDLOAD 40 1 SPARE B 20 11 1 1 KVA 42 ISPARE C 20 11 1 1 AMPS NOTES(REBARKS : 1. LOAD 2. 3. DEMAND/ DIVERSITY FACTORS DESCRIPTION DEMAND R RECEPTACLES -TO 10KVA 100% _ RE3MAINNG OVER 10KVA 50% _ H HEATING 100% _ M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% _ 0 OTHER 100% _ TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 ENGINEERINGCASE Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 REVIEWED FUh COMPLIANCE WITh NFPA 70 - NFC SEP 0 4 2015 City of Tukwila BUILDING DIVISION Project Title: Tenant Improvement for: BECU TUI{�X'ILA 12770 Gateway Dr. Tukwila, WA 98168 PANEL: H6 PROJECT NAME BECU TUKWI LA PROJECT #: 15110 LOCATION: FLOOR 6 FED FROM: 400A DISCONNECT NOTE CKT NO. CIRCUIT NAME CB SIZE LOAD (KVA) PANEL DESCRIPTION 8 AM P R H M L K 0 TOTAL 2 1 LTS- ENCLOSED OFFICES A 20 3 2.8 2.8 PANE -AMPS : 225 3 SPARE B - - - FEEDER AMPS : 225 5 SPARE C -- - L- L VOLTS : 480 2 7 FPTU 625 A 20 1 3.0 0.7 3.7 L - N VOLTS : 277 2 9 FPTU 617 B 20 1 3.5 0.7 4.2 PHASE : 3 11 SPARE C 20 1 WIRE : 4 13 SPARE A 20 1 3 15 FPTU 615 B 30 1 5.0 0.7 5.7 2 17 VAV 602 C 30 1 4.5 0.7 5.2 2 19 FPTU 618 A 20 1 3.0 0.7 3.7 M.L.O. 2 21 FPTU 606 B 20 1 3.0 0.7 3.7 MAIN CB X 2 23 FPTU 607 C1 20 1 3.0 0.7 3.7 FLUSH 2 25 FPTU 604,623 A 30 3 4.0 4.0 SURFACE X 2 27 - - - B - - - 4.0 0.7 4.7 ISO GND FEED-THRU 2 29 - - - C - - - 4.0 0.7 4.7 2 31 FPTU 605,608 A 30 3 4.0 1 1 4.0 2 33 --- B -- 4.0 1.1 5.1 2 35 1 --- C - 4.0 1.1 5.1 2 37 FPTU601,603 A 40 3 5.6 0.7 6.3 LOADSUMMARY 2 39 - - - B - - - 5.6 0.7 6.3 ( TOTAL, ALL SECTIONS) 2 41 --- C -- - 5.6 1.1 6.7 REC KVA 2 2 LTS-OPEN OFFICE A 20 1 2.5 2.5 4 SPARE B 20 1 HEAT KNA : 102.7 6 SPARE C 20 1 MOTOR KVA : 18.1 8 SPARE A 20 1 LIGHTING KVA : 5.3 10 SPARE B 20 1 KITCHEN KVA OTHER KVA 12 SPARE C 20 1 1 14 EF 1,2,3 ON ROOF A 20 3 1.4 1.4 1 16 --- B -- - 1.4 1.4 PI-ASEA KVA : 38.7 1 18 --- C -- - 1.4 1.4 AMPS : 139.7 2 20 FPTU 629 A 20 1 2.0 0.7 2.7 PHASE B KVA : 45.5 2 22 FPTU 610 B 20 1 AMPS : 164.3 2 24 FPTU 626 C 20 1 2.0 1 0.7 2.7 PHASE C K VA : 41.9 AMPS : 151.3 2 26 FPTU614 A 20 1 3.0 0.7 3.7 2 28 FPTU 613 B 1 20 1 3.5 0.7 4.2 2 30 FPTU 622 C 20 1 3.0 0.7 3.7 32 IVAV 620 A 20 1 CONNECTED LOAD 3 34 FPTU 609 B 30 1 4.5 0.7 1 _ 5.2 KVA : 126.1 2 36 FPTU 619 C 20 1 3.0 0.7 3,7 AMPS : 151.7 3 38 FPTU 610, 612 A 30 3 3.9 3.9 DEMAND LOAD 3 40 - - - B - - - 3.9 1.1 5.0 INA : 127.7 3 42 --- C -- - 3.9 1.1 5.0 AMPS : 153.6 NOTES/REMARKS: 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER INDICATED DEMAN )I DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% _ REMAINING OVER 10K VA 50% _ H HEATING 100% = 102.7 M MOTORS 100% = 17.0 LM LARGEST MOTOR 125% = 1.4 L LIGHTING 125% = 6.6 K KITCHEN 65% _ 0 OTHER 100% _ PANEL: L6 (SECTION 1) PROJECT NAME BBCU TUKWILA PROJECT #: 15110 LOCATION: FLOOR 6 FED FROM: 150 KVA XFMR T6 NOTE CKT NO. CIRCUIT NAME CBSIZE 0 AMP LOAD(KVA) PANEL DESCRIPTION PI R H M L K 0 TOTAL 1 SPARE A 20 1 PANEL AMPS : 225 3 SPARE B 20 1 FEEDERAMPS : 225 L - L VOLTS : 208 2 5 REC @ DESKS OFFICES 617,618,619 -1 C 20 1 0.9 0.9 2 7 REC @ DESKS OFFICES 614,615,616,617 A 20 1 1.3 1 1.3 L - N VOLTS : 120 9 SPARE B 20 1 PHASE: 3 2 11 REC@ DESKS OFFICES 611,612,613 C 20 1 0.9 0.9 WIRE : 4 2 13 REC OFFICES 611,612,613 A 20 1 0.5 0.5 2 15 FLATSCREEN REC OONF RM 610 B 20 1 0.3 0.3 M. L.O. 2 17 FLOOR BOX REC CONF RM 610 C 20 1 j 0.4 0.4 2 19 REC CONF RM 610 A 20 1 0.7 0.7 MAIN CB X 2 21 CONY REC HALLWAY SE,SW, SCHEDULERS B 20 1 0.8 0.8 FLUSH 2 23 WDRK STATIONS SW C 20 1 0.6 0.6 SURFACE X 2 25 WDRK STATIONS SE A 20 1 0.6 0.6 ISO GND 2 27 EXH FAN EF6-03 B 20 1 1 0.7 0.7 FEED-THRU IIX 2 29 EXH FAN EF6-01, 02 C 20 1 1.7 1.7 31 SPARE A 20 1 33 SPARE B 20 1 35 SPARE C 20 1 37 SPARE A 20 1 LOADSUMMARY 1 39 EXISTING EF-15 B 20 1 0.3 0.3 ( TOTAL, ALL SECTIONS) 1 41 EXISTING EF-16 C 20 1 0.3 0.3 REC KVA : 20.5 2 2 GFCI CATERING KITCHEN A 20 1 0.4 0.4 2 4 DEDICATED GFCI CATERING KITCHEN B 20 1 1.2 1.2 HEAT KVA : 2.0 2 6 DEDICATED GFCI CATERING KITCHEN C 20 1 1.2 1.2 MOTOR KVA : 3.0 2 8 DEDICATED GFCI CATERING KITCHEN A 20 1 1.2 1.2 LIGHTING KVA : 4.6 2 10 GARBAGE DISPOSAL RECCATERING KITCHEI B 20 1 1.2 1.2 KITCHEN K \/A 2 12 DISHWASHER REC CATERING KITCHEN C 20 1 1.2 1.2 OTHER KVA : 39.1 2 14 DEDICATED GFCI CATERING KITCHEN A 20 1 1.2 1.2 2 16 MICROWAVE REC CATERING KITCHEN B 20 1 1.2 1.2 PHASEA KVA : 24.2 2 18 MICROWAVE REC CATERING KITCHEN C 20 1 1.2 1.2 AMPS : 201.7 2 20 REFER REC CATERING KITCHEN A 20 1 1.0 1.0 PHASE B KVA : 22.7 2 22 FLOOR BOX REC,COW REC LOUNGE B 20 1 0.9 0.9 AMPS : 189.2 2 24 FLATSCREEN REC LOUNGE C 20 1 0.3 0.3 PHASEC KVA : 23.3 2 26 FLATSCREEN REC LOUNGE A 20 1 0.3 0.3 AMPS : 194.2 1 28 EXISTING SECURITY CAMERAS, FIRE STROBE B 20 1 1 0.5 0.5 30 SPARE C 20 1 32 SPARE A 20 11 CONNECTED LOAD 34 SPARE B 20 1 KVA : 69.2 36 SPARE C 20 1 AMPS : 192.1 3 38 NEW TVSS A 20 3 0.1 0.1 DEMAND LOAD 3 40 - - - B - - 0.1 0.1 KVA : 65.5 3 42 --- C1 0.1 0.1 AMPS : 181.9 NOTESIREMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MOCIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER AS INDICATED DEMAND! DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 10.0 REMAINING OVER 10KVA 50% = 5.3 H HEATING 100% = 2.0 M MOTORS 100% = 1.3 LM LARGEST MOTOR 125% = 2.1 L LIGHTING 125% = 5.8 K KITCHEN 65% _ 0 OTHER 100% = 39.1 PANEL: 1-613 (SECTION 2) PROJECT NAME B6CU TUKWILA PROJECT #: 15110 LOCATION: FLOOR6 FED FROM: PANEL L6 NOTE CKT NO. CIRCUIT NAME CBSIZE 8 AMP LOAD (KVA) PANEL DESCRIPTION P R H I M I L I K 1 0 TOTAL 2 1 WORK STATIONS NW A 20 11 1 1 0.9 0.9 PANEL AMPS : 225 2 3 WORK STATIONS NW B 20 1 0.9 0.9 FEEDER AMPS : 225 2 5 WORK STATIONS NW C 20 1 0.9 0.9 L - L VOLTS : 208 2 7 WORK STATIONS NW A 20 1 0.9 0.9 L - N VOLTS : 120 2� 9 WORK STATIONS NW B 20 1 0.9 0.9 PHASE: 3 2 11 WORK STATIONS NW C 20 1 0.9 0.9 WIRE : 4 2 13 WORK STATIONS NW A 20 1 0.4 0.4 2 15 WORK STATIONS NW B 20 1 0.9 0.9 M.L.O. X 2 17 WORK STATIONS NW C 20 1 0.9 0.9 2 19 CONY REC NE MN A 20 1 0.9 0.9 MAIN CB 2 21 WORK STATION NE B 20 1 1.2 1.2 FLUSH 2 23 WORK STATION NE C 20 1 0.3 0.3 SURFACE X 2 25 REC OFFICES 647,648 A 1 20 11 0.7 0.7 ISO GND 27 SPARE B 20 1 FEED-THRU X 2 29 COUNTER RECS - COPY RM 649 C 20 1 0.2 0.2 2 31 COUNTER RECS - COPY RM 649 A 20 1 0.4 0.4 2 33 COUNTER RECS - COPY RM 603 B 20 1 0.4 0.4 2 35 COUNTER RECS - COPY RM 603 C 20 1 0.6 0.6 37 SPARE A 20 1 LOADSUMMARY 39 SPARE B 20 1 (TOTAL, ALL SECTIONS) 41 SPARE C 20 1 REC KVA : 13.7 2 2 GFCI REC PANTRY A 20 1 0.4 0.4 2 4 DEDICATED GFCI RECEPTACLE PANTRY B 20 1 1.2 1.2 HEAT KVA : 2.0 2 6 REC PANTRY, HALLWAY VVEST,BOARDROIC C 20 1 1.6 �1.2 1.6 MOTOR KCVA 8 SPARE A 20 1 1.2 LIGHTING KVA : 4.6 10 SPARE B 20 1 1.2 1.2 KITCHEN KVA OTHER KVA : 25.6 12 SPARE 20 1 1.2 1.2 14 SPARE A 20 1 0.4 0.4 16 SPARE B 20 1 0.4 1 0A PI-IASEA KVA : 16.9 18 SPARE C 20 1 0.4 1 0.4 AMPS : 140.8 20 SPARE A 20 1 0.4 0.4 PHASE KVA : 15.5 22 SPARE B 20 1 0.4 0.4 AMPS : 129.2 24 SPARE C 20 1 0.4 0.4 PHASE CKVA : 14.5 26 SPARE A 20 1 1.0 1.0 AMPS : 120.8 28 SPARE B 20 1 0.6 0.6 2 30 FLATSCREEN REC CONF RM 601 C 20 1 0.3 0.3 2 32 FLOOR BOX REC CONF RM 601 A 20 1 0.4 0.4 CONNECTED LOAD 2 34 REC CONF RM 601 B 20 1 0.7 0.7 KVA : 45.9 36 SPARE C 20 1 AMPS : 127.4 38 SPARE A 20 1 DEMANDLOAD 40 SPARE BJ 20 1 KVA : 45.2 42 SPARE C 20 1 AMPS : 125.5 NOTESIREMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT mounED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKER INDICATED LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 10.0 REMAINING OVER 10KVA 50% = 1.9 H HEATING 100% = 2.0 M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% = 5.8 K KITCHEN 65% _ 0 OTHER 100% = 25.6 PANEL: L6C (SECTION 3) PROJECT NAME BECU TUKWILA PROJECT #: 15110 LOCATION: FLOOR FED FROM: PANEL L6B NOTE CKT NO. CIRCUIT NAME CBSIZE 0 AMPI LOAD (KVA) PANEL DESCRIPTION PI R I H M L K 0 TOTAL 2 1 WORK STATIONS NE A 20 1 0.6 0.6 PANEL AMPS : 225 2 3 WORKSTATIONS NE B 20 1 0.6 0.6 FEEDER A MPS : 226 L - L VOLTS : 208 2 5 VVIORK STATIONS NE C 20 1 0.6 0.6 2 7 WORKSTATIONS NE A 20 1 0.6 0.6 L - N VOLTS : 120 2 9 VIORK STATIONS NE B 20 1 0.9 0.9 PHASE : 3 2 11 WORK STATIONS NE C 20 1 0.9 0.9 WIRE : 4 2 13 WORKSTATIONS NE A 20 1 0.9 0.9 2 15 WORK STATIONS NE B 20 1 0.9 0.9 M L.O. X 17 SPARE C 20 1 2 19 REC@ DESKS OFFICES655,666,667 A 20 1 1.1 1.1 MAIN CB 2 21 FLATSCREEN REC CONF RM 654 B 20 11 0.3 0.3 FLUSH 2 23 FLOOR BOX REC CONF RM 654 C 20 11 0.4 0.4 SURFACE X 2 25 REC CONF RM 654 A 20 1 0.6 0.5 ISO GND 2 27 CONY REC HALLWAYS B 20 1 1.1 1.1 FEED-THRU X 2 29 LTS-OPEN OFFICE C 20 1 0.5 0.5 2 31 LTS-LOUNGE A 20 1 0.5 0.5 33 SPARE B 20 1 35 SPARE C 20 1 37 SPARE A 20 1 LOADSUMMARY 39 SPARE B 20 1 ( TOTAL, ALL SECTIONS) 41 SPARE C 20 1 REC KVA : 4.6 2 2 COPIER REC COPY RM 603 Al20 1 1.5 1.5 2 4 REC COPY RM 603 BI 20 1 0.5 0.5 HEAT KVA : 2.0 2 6 REC DOPY RIN 603 C 20 1 0.4 0.4 MOTOR KCVA 8 SPARE A 20 1 LIGHTING KVA : 4.6 2 10 CONY REC LOUNGE B 20 1 0.2 0.2 KITCHEN KVA OTHER KVA : 10.2 12 SPARE C 20 1 2 14 EXISTING BATHROOM REC A 20 1 0.4 0.4 1 16 EXISTING MENS RM HAND DRYER B 20 1 1.0 1.0 PHASEA KVA : 8.9 1 18 EXISTING WOMENS RM HAND DRY ER C 20 1 1.0 - 1.0 AMPS : 74.2 1 20 EXISTING BECU SIGN A 20 1 1.8 1.8 PHASE B KVA : 6.7 1 22 EXISTING SPARE ROOF TOP B 20 1 AMPS : 55.8 1 24 EXISTING BECU SIGN C 20 1 1.8 1 1.8 PHA SEC KVA : 6.8 1 26 EXISTING SPARE ROOF TOP A 20 1 AMPS : 56.7 28 SPARE B 20 1 30 SPARE C 20 1 32 SPARE A 20 1 CONNECTED LOAD 1 34 EXISTING ROOF TOP REC B 30 2 11.2 1.2 KVA : 21.4 1 36 - - - C - - - 1.2 1.2 AMPS : 59.4 38 SPARE A 20 1 DEMAND LOAD 40 SPARE B 20 1 KVA : 22.6 42 SPARE 1C1 20 1 AMPS : 62.6 NOTES/REMARKS : 1. EXISTING CIRCUIT 2. EXISTING CIRCUIT MODIFIED BY THIS PROJECT 3. PROVIDE NEW CIRCUIT BREAKERAS INDICATED LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 1000/0 = 4.6 REMAINING OVER 10KVA 50% _ H HEATING 1000/0 = 2.0 M MOTORS 1000/0 _ LM LARGEST MOTOR 125% _ L LIGHTING 125% = 5.8 K KITCHEN 65% _ 0 OTHER 100% = 10.2 PANEL: LC13 PROJECT NAME BECU TUKWI LA PROJECT #: 15110 LOCATION: FLOOR 6 FED FROM LC7 (6TH FLOOR) NOTE CKT NO. CIRCUIT NAME CB SIZE LOAD (KVA) PANEL DESCRIPTION 9 AMq PI R H I M L K 1 0 TOTAL 1 SPARE A 20 11 1 1 PANEL AMPS : 100 FEEDER AMPS : 100 3 SPARE B 20 11 5 WORKSTATIONS V1LOPEN OFFICE 652 C 20 1 0.6 0.6 L - L VOLTS : 208 7 WORKSTATIONS SW- OPEN OFFICE 630 A 20 1 0.9 0.9 L - N VOLTS : 120 9 WORKSTATIONS SW- OPEN OFFICE 630 B 20 1 0.9 0.9 PHASE : 3 11 RECS - W OFFICES 645, 647 C 20 1 0.6 0.6 WIRE: 4 13 WORKSTATIONS W - OPEN OFFICE 650 A 20 1 1.2 1.2 15 WORKSTATIONS W - OPEN OFFICE 652 B 20 1 1.2 1.2 17 RECS - OFFICES 655,656,657 C 20 1 0.9 0.9 19 RECS - OPEN OFFICE N 652 A 20 1 0.9 0.9 M. L.O. 21 RECS - OPEN OFFICE N 652 B 20 1 0.9 0.9 MAIN CB FLUSH X 23 RECS- CONF RM 610 C 20 1 0.4 0.4 25 RECS- OFFICES 611,612,613 A 20 1 0.9 0.9 SURFACE X 27 RECS - OFFICES 614,615,616 B 20 1 0.9 0.9 ISO GND 29 RECS- OFFICES 617,618,619 C 20 1 0.9 0.9 FEED-THRU 31 SPARE A 20 1 33 SPARE B 20 1 35 SPARE C 20 1 37 SPARE A 20 1 LOADSUMMARY 39 SPARE B 20 1 ( TOTAL, ALL SECTIONS) 41 SPARE C 2D 1 REC KVA : 2.8 2-.DEDICATED QUAD REC BOARDROOM 629 A 20 1 1.2 1.2 4 DEDICATEDQUAD REC BOARDROOM 629 B 20 1 1.2 1.2 HEAT KVA 6 DEDICATED QUAD REC BOARDROOM 629 C 20 1 1.2 1.2 MOTOR KVA 8 FLOOR BOX REC BOARDROOM 629 i A 20 1 0.4 0.4 LIGHTING KVA 10 FLOOR BOX REC BOARDROOM 629 B 20 1 0.4 0.4 KITCHEN KVA : 5.5 12 FLOOR BOX REC BOARDROOM 629 C 20 1 0.4 0.4 OTHER KVA : 15.0 14 FLOOR BOX REC BOARDROOM 629 A 20 1 0.4 0.4 16 FLOOR BOX REC BOARDROOM 629 B 20 1 0.4 0.4 PHASEA KNA : 9.0 18 FLOOR BOX REC BOARDROOM 629 C 20 1 0.4 0.4 AMPS : 75.0 20 REC PROJ/SCREEN BOARDROOM 629 A 20 1 1.0 1.0 PHASE B KVA : 7.7 22 FLATSCREEN REC BOARDROOM 629 B 20 1 0.6 0.6 AMPS : 64.2 24 FLATSCREEN REC CONF RM 601 C 20 1 0.3 0.3 PHASE C KVA : 6.6 26 RECS - EAST OPEN OFFICES 6TH FLR A 20 1 1.2 1.2 AMPS : 55.0 28 RECS - EAST OPEN OFFICES 6TH FLR B 20 1 1.2 1.2 30 RECS - WEST OPEN OFFICES 630 C 20 1 0.9 0.9 32 RECS - WEST OPEN OFFICES 630 A 20 1 0.9 0.9 CONNECTED LOAD 34 SPARE B 20 1 KVA : 23.3 36 SPARE C 20 1 AMPS : 64.7 38 SPARE A 20 1 DEMAND LOAD 40 SPARE BI 20 1 KVA : 21.4 42 ISFARE Cl-20- 1 AMPS : 59.3 NOTES/REMARKS: 1. 2. 3. DEMAND DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 2.8 REMAINING OVER 10KVA 50% _ H HEATING 100% _ M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% _ K KITCHEN 65% = 3.6 0 OTHER 100% = 15.0 Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 PERMIT SET 8-10-15 REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC SEP 0 4 2015 City ofTuWla BUILDING DIVISION Project Title: Tenant Improvement for: BECU TUKWILA 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: 6TH FLR PANEL R E; t; V E oSCHEDULES CITY OF TUKWILA AUG 12. 2015 PERMIT CENTER Designed By: RB Drawn By: MB Project No: 15110 Date: 08/05/2015 Sheet Number: CONE 159 GENERAL NOTES CONNECT ALL 120/208V DEVICES TO INDICATED CIRCUIT IN EXISTING NORMAL POWER PANELS 'L1, 1-16' UPS PANELS 'LC6, LC8, LC10' OR STAND BY PANEL "LGE" UNLESS OTHERWISE NOTED. POWER/COMM DEVICES IN AREA ARE EXISTING TO RI NEW WORK. PERNUT SET 8-10-15 REVIEWED .FOR f COMPLIANCE WITH NFPA 70 - NEC SEP 0 4 2015 City of Tukwila i SUIT nING DIVISION Project Title: Tenant Improvement for: BECU TUKWILA 12770 Gateway Dr. 12 Tukwila, WA 98168 -T Sheet Title: 1ST FLOOR Ll S 0 6q, q POWER AND 1 ST FLOOR POWER/COMMUNICATION SCALE: 1/8" = 1'-0" A B (C D E (F tG H TJ I I I I I I I I I I I I I I I I I I I I I I I I I I I co , j CE) 0 0 CE) 0 0 CLDI CEP co 0 co C0 co co Co OPEN / I 02716E L2A �r6,38 L2A 32,34 -28,30 -24,26 LM-12,14 LC1 -15 CC)LC1 7,9 CD LC 4j11,13 C14-15,17— I I I i I I - - --- - -- - j--- - - - - - - - - - -- -- - --- - - - -- - f --6FF 12f - - j -L2A= i E: -T] 6 j - ---- - L-) 272 L2A-25 • A �2A cocoL- 3 L2A- 81 -16 I � _ coN� L2A- 16 LC14-5I 273 L2A-16 :L L2A-1 HALLWAY L2A-25 I I I 1275 I I I COPY To 0 _ j Ib1�1 i6L-261 E-8 UA-1 • j L2A-17 L2A 3 L2A-7BREAKOUT jOA� CAM 255] I I L2A-27 t` A-27 ; OPEN (tom-27 - -- - - - - - OFFICE - �T J] 254 j LUA42 I NF 2 9 L2A-27 �. L2A-2P 0 _ -7 j11117 PHONE PHONE 248 ?_47 I - L2 -9 LC1 8 CO 0 I 0 CICED L2C-30 co 01 co 11 M- ,31,33 I I I I 0 (� OPEN OFFICE [ 250 co co I I I I I 0 I I I I I FLAG NOTES [1>VERIFY LOCATION OF NEW PANEL 'LC14' PRIOR TO ROUGH —IN. L2D (E) (E) STORAGE [-2-TB- J L2C K LI- j I I I I I I I I I I I I I ► I I I I I I I I I I I I I I I I I I - co C�] B-16 26-12 `A-250i L26-10 I L2A 4,6 LC1d 32 B-16 B-12 - ® PROJECTOR 1­26-31- L26-29 B-14 B-18 BREAKOUT 2.06 co i B-14 9 62131-1861�� ,10 L2 2 L2B-10 LC14-3 j 0 04-8 OIN — SCREEN j — y 8 L26-29 LG T L j (RE )1 B-30 LG -3 HALLWAY I 208 I ( F) L28-29 I L26-30 �� L26-30 PANTRY QV- C NF L2B-20 STOR W L2 -17 II \ 7 21 7 M 17LC j 4-10 *L2B-30 218 I - ir L2B 23 �� I �VEND jVEND VEND [� LZU I I LYtf-J I LZb-� 4- A_ - LC14-10 . AV - B 2 Z�B�--L-2B---1-1 - j- STAIR DISP L2B-20 209 - - -- 0 - - - -- -- - I — - - - - - — - - -- -- - j-t26=t9 t2 -19- L20- COPY TD STORAGE ELEVATOR L B-21 ROOM LC u� 1 201 - I L� ��Y 4_82 LCB _ i 212 I HALLWAY C,-_- 244 T 0 L2B-28C26-28 / B-21 COP OPENO OFFICE L26-30 � - LGE. OFFICE OFFICE OFFICE � � � 1 220 I / 210 211 ; L B-21 I0 214 - ' (� L2C-29 j� I� HALLWAY L2C-30 251 I L2C-30 I L2C-30 L2C-32 / -- -- -- - - -- ram= --�- - -- �-� - = j OFFICE -- -L2c-2 - ---.---�- - - 1� 21 L 1 -31 L2C-8 - C 4 C -31 26 L2C 2 26 L2C_ 2 L2 -32 BREAKOUT A-39 L2C- L2C-2 1 I (/ L2C-25 q2C-4tFV L2C- VL2C-18 L2C 0 0F LZC � �- OFFICE CONE C-18 - - - - - - 39 - - - LC14 16 FILEL114-16S j - - - - - LC - 2_ OFFICE - -- -- - -- L2C-81 FILE/WORK I L2C- 4 I OPEN 213 222 L2C_8 ROOM L2C-24 OFFICE 238 C 22 (� 241 0 co 8L2C-30 C-V �C_2 2C- 2 LC14_16 L2 -32 37 C1 1-2 L101 F L2C-25 I I LC14-16 I 1 j 1 240 L2C-30 _ -- L -32 OFFICE L2C-30 2 2 3 L2C-32 -39-L2CT25- - - - OFF) OFF E OF 10E OFF CE OF ICE OFF CE CON 2��ENCE L 4-39 OFFICE OFFICE 0 _ E 0 237 236 235 4 23 3� 23`I 30 riM MM M = 1111 1 I L2C -1 - L2C-3 LC14-35 L2C-5 - 14_37 L2C-30 �C_1 L2C-1 4 3 LC1JC-3- L2C-5 14 37 L2C- L2C-3 L2C-5 L2C-5 L2C-5 �Ci 35 L 14-3-9 O L - 3 0 � '6 0 ICI S O Firl `:71 ri 1 71 GENERAL NOTES 1 • CONNECT ALL 120/208V DEVICES TO INDICATED CIRCUIT IN EXISTING PANELS 'L2A, L2B, L2C', STAND BY PANEL 'LGE' OR UPS PANEL 'LC14' UNLESS NOTED OTHERWISE. 2. PROVIDE 2" C.O. SLEEVE THRU FLOOR AT CONFERENCE ROOM A/V OUTLET AND FLOOR BOX —TYPICAL AT ALL CONFERENCE ROOMS. 2ND FLOOR POWER/COMMUNICATIO SCALE: 1 /8" = 1'-0" CASE ENGINEERINI Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 PERMIT SET 8-10-15 REVIEWED .FOR COMPLIANCE �IIThI NFPA 70 - NEC SEP 0 4 2015 — City ofTukWila BUILDING DIVISION Project Title: Tenant Improvement for: BECU TUKWILA 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: 2ND FLOOR POWER AND GENERAL NOTES 1. CONNECT ALL 120/208V DEVICES TO INDICATED CIRCUITS IN PANELS L3, L3B, L3C, L3E, L3F, OR LC11 UNLESS NOTED OTHERWISE. 3RD FLOOR POWER/COMMUNICATIONS PLAN SCALE: 1 /8" = V-0" E m RECE.1VIE- D CITY OF TUKWILA AUG 12 2015 PERMIT CENTER G� G � R l i E . Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 PERMIT SET 8-10-15 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC SEP 0 4 2015 City of Tukwila BUILDING DIVISION Project Title: Tenant Improvement for: BECU TUKWILA 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: 3RD FLOOR POWER AND COMMUNICATIONS PLAN Designed By: RB Drawn By: MB Project No: 15110 Date: 08/05/2015 2. PROVIDE 2" C.O. SLEEVE THRU FLOOR AT CONFERENCE ROOM A/V OUTLET AND FLOOR BOX — TYPICAL AT ALL CONFERENCE ROOMS. Sheet Number: E1.3 A) B C D ?E co 10 co 17,1.21 9 L4E -9,11 LC12 19 CD 0 01 C — --::P - kE 0 P I OFFJco 0 45 B L46-8 BREAKOU I I I I I L4B -33 CD ---------- -7­ _F_ TF G H i K L m N 0 p Q R S L4--1*0- -L4=1-0- BREAKOUT co co co co cm 406 BREAKOU 34 �L4-12 L4 0 0 CD 0 COD --L4H-21 461 PANTRY VL4 - 4P;NF REF E 0=7 L4H-§ IV4 L 415 Ld -12 12 1 L4H-31 L4 7 'A - MOUNT IN TOE KICK L41-1-21 0 Cm co co I co c0i co _" 5-L4-12 QA%/1 [E] CONE SPACE UNDER BENCH. 0_1 1_41H-33,604 1 -25 000 �ICRO- -DISP FT L'ItE L4b -1LC12-15,17 L4 8 L4H -1L4H-7 L4H-29 CO L4H- MICRO 23= nut HOTEL HO EL_ CON 1 4 L48 - L48-1 0 1_413-1 L4B_1 6)@L4"2 L4B-I, LC12-1 E 2LC12-1 Do L4B STg� �E (E) 4 _ (E) XFMR E)L4C (E) (E) 511 Qq E)L4D F 4 3, HALLWAY //W I IlAr-Af) 1 0 L l- L 41 H-1 5 L4H--'I I _-REE, L4-16 L4H-194 Hz;_ I GE�3VLGE, a 4 �-4 OFFICE A L4 1 _-QUAL 459 =h4C=19 *14 L4-20 %5 1_413-1, L4C- 1 (1 LC11 9 L4H-35 L4H- L4H-35 '51 SCREE 0 3 L4H-35 J I I I 1_414-35 I I F L4-42 I HALLWAY L4-�2 3-----: EN L4E 12 L4B­14,16 CE) 0 _C1 -6,E T_ co 1. FLAG NOTES [�> VERIFY LOCATION OF NEW PANELS LC11 AND LC12 PRIOR TO ROUGH -IN. [2�> VERIFY LOCATION OF EXISTING PANELS L4G AND L4H. 6 L 4 M=EE T_ EuT F 2=4 L • L4 -12 00 4B-. 16,18 L4B- 28 L4B-. 28,30 L4C 4,6 L4C-.6,8, L4C. 10 L4C- 14.1' CD 0 0 _C12 -1 0,1?0 0 C1 2­14,11 Q rah rah 0 _C12 -18,2 Q 0 0 ---=— - - - -- - - -OPEN - - I— - -- - --�--- - - - / �- -- -- ---- - -- 1 0 OFFICE co Cm 0 co 430 0 0 co 0 0 co co r_ 11 0 D 12-27 D Z - 10 VIR NFC RECORD STORAGE j14 k,4-16 CONF0 L4C -19 L _4Jlfl Vo�j* LC12+13 11 41Q I I .__ (I 61 L4q4&2 Lt. A 5I2 IDF LC12-�914, C LC12-2%g L4G- 11 ELEVATOR LOBBY 1 400 L4G- 11 DO L4C-40 0 HALLWAY L4C-40 E XFMR.,,. G_5PH NE -42 L4G-5 TORAGE %0 4klJN-, .......... L 418 L4G (E) tn ROJ 4,4H —L4G---S4- _t4G�­t_ 1OF tG 2-7 (A np _0 CWF=-3 � ce L4C-22,24, L4G L4G-n Q) LC12-22,24 A Z-V->i E,Z 0 I L4C-40 I V 29 CE Lj 36 GENERAL NOTES 1. CONNECT ALL 120/208V DEVICES TO INDICATED CIRCUIT IN EXISTING PANELS L4, L413, L4C, L4H, L4G STANDBY PANEL LGE AND UPS PANEL LC12 UNLESS NOTED OTHERWISE. 2. PROVIDE 2" C.O. SLEEVE THRU FLOOR AT CONFERENCE ROOM A/V OUTLET AND FLOOR BOX - TYPICAL AT ALL CONFERENCE ROOMS. HALLWAY ET=2 � po *)-40 7 B-4u OPE OFFI( 4TH FLOOR POWER/COMMUNICATIO SCALE: 1/8" = 1'-0" TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 Z-1:731 CASh .0 . = W ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 BECU TUKWII.A 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: G; ,H J; K' L FLAG NOTES [E:�> VERIFY LOCATION OF EXISTING PANEL LC9. M N 0 P Q R S r' I I � � r C 7 LO L Z'040)v �50 4D V LC1-33 EAKOUT OFFICE 534 OFFICE 33- OFFICE __ I — — � GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANELS 15, 1_513, L5C", STAND BY PANEL 'LGE' OR UPS PANELS 'LC1, LC2' UNLESS NOTED OTHERWISE. 2. PROVIDE 2" C.O. SLEEVE THRU FLOOR AT CONFERENCE ROOM A/V OUTLET AND FLOOR BOX —TYPICAL AT ALL CONFERENCE ROOMS. 5TH FLOOR POWER/COMMUNICATION SCALE: 1 /8" = 1'-0" -08 TITAN ELECTRIC FULL SERVICE ELECTRICAL. CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 Project Title: Tenant Improvement for: BECU TUKWILA 12770 Gateway Dr. Tukwila, WA 98168 A i B 1 C (D 'E tG .H i TJ Ki ��' 0 L6C-27 _ (� C� co L - 58 L1,13-23al5q; LC13-1 LC13-210��o L - I I I I I I I I I I 23AV1 • LC 1,3 LC- L6C 11 L6C-13 L6C-13 L6C-15 L6C-15 LC-1 LC -5 LCt - 6C 5,7 LC13-19 LC13-19 LC13-21 LC13-21 I T6 OPEN L6C-$7 CONF C1 15 OFFICE 652 - 1 �610 OFFICE _ OFFI E OFFICE ONF -- - - - - - - L66-19 - - - — -I=L6C-27 - 657 65 -m-m- -ri- 655 54 F- L6C L6-19 - s e LC- 9 -19 119 L I L6C 19 a L6C 25 U - L 13-1`/I -1i L6C-2 L6 -21 L69 A HALLWAY 1 I L6C-27 I 1 �� L6_ 21 649 - a - LGE-40 DISCON T - Lfi6- 1 - DIS AF L6C L6 LC13 ' f 7 TO PAI1EL- (E) (E) _ --- t B-340- XFMR (E) _25 _ 225AF L68 LC 11 DISCON qECT L6B- 1 O TO PAISEL-L5 LC13 13 / I I I j L6P-29 0 4 k` -- - - - - - - QF EN ICE. - - �FFirE - HA LWAY i I I L66-25 1 44 / 0 0 LC13-25 O I I I E (� (� O FF I C -/ // 2 I I I1_66-26 1_613-13 LC11 -24 R L6 -214-- O �IHill CO 1 6 1 ] / L�-34 __- L6 mw 1.6F3- — ]F T - -� L66-34 L68- .� LOUNGE I 66-28 STOR GE • / 641(DFI%' El 01 ......... .. / - / — / - HALLWAY I 6 I 31 L6C-6 Q n -- L6-24AV -1 LC13-24---®13-20 LC1�3-24 - -- I I I U U I U U I LJ W 0 Q 0 QA 00 Qt3D 0 Q L 12 I LOUNGE I I 10 LC 13-22 6 2.8 BREAI:OU _ -_-- L6-26 C 632 D -A&• e e - - - — - - - 6B-19 /� -- - - - - — - - - - - - - - - - - - 30 L6C-6 �� e �- FFICE - -tC13- co 630 Co BOARDROOM LC13-2094 LC13- I J 629 LC13- LC13-14 LC13-16 LC13-18 6C-6 L66 1,9 L66 5,7 LCB 130 39V • I • • LC13 o P Q R I I I I I I I I I I I I I I I I I I I I 6- L5-11 - 5 5 1 6 L02 I I I EJ� �Ed DE I OFFICE OFFICE OFFICE 611 - -612 -- 613 1 -- - El 27 OFF �n 614 I 1_66-21 L68-21 11-66-21 LC13-26 LC13-26 LC13-26 O 1L6-21 I I 7 L - 1 [ I L6-21 D L 26 q-� OFFICE IN Jam' 615_ Ca F C E —CI-- 6-7 // I OFFICE 7o '1 616 I -moo GENERAL NOTES 1. CONNECT ALL 120/208V DEVICES TO INDICATED CIRCUIT IN PANELS L6, LC13, LGE, LC, L6B, LC11, AND L6C UNLESS NOTED OTHERWISE. 2. PROVIDE 2" C.O. SLEEVE THRU FLOOR AT CONFERENCE ROOM A/V OUTLET AND FLOOR BOX - TYPICAL AT ALL CONFERENCE ROOMS. L6-21 O-- OFFICE 618 OFFICE 619 I O OFFICE 617 6TH FLOOR POWER/ COMM UNICATIO SCALE: 1 /8" = 1'-0" S I s4ft-0649 TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 CASh 'iM a ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 REVIEWED.F®R I COMPLIANCE WITH NFPA 7o - NEC sEP o 4 zo�5 City of TukW BUILDING DIVISION Project Title: Tenant Improvement for: BECU TUKWILA 12770 Gateway Dr. Tukwila, WA 98168 I I I G H J K L M N 0 P I I I I i I K�1K1 K ILFCE UFE OaFF4CE OFFICE® •------- - -..i FFICE _�.z�.. I „• �/dfdr:/./.:�ffddfG:�TfrS'.!7/dam: �I e 1 MAIN u I •0 s i%liddfdii7fsdfiTiddiddiddi//.3 �1 e GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H1A UNLESS OTHERWISE NOTED. O i. RECEIP' ED CITY OF TUKWILA AUG 12 2015 PERMIT CENTER 2 TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 C A S E ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 REVIEW.ED.FOH COMPLIANCE WITH NFPA 70 - NFC SEP 0 4 2015 City of-TUkWifa BUILDING DIVISION Project Title: Tenant Improvement for: BECU TUKWILA Sheet Title: 1ST FLOOR LIGHTING PLAN Designed By: RB Drawn By: MB Project No: 15110 Date: 08/05/2015 Sheet Number: E2.1 GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL XX UNLESS OTHERWISE NOTED. 2ND FLOOR LIGHTING PLAN SCALE: 1 /8" = 1'-0" �/l -08 i RECE;VC0 CITY OF TIJf'%WILA TITAN ELECTRIC FULL SERVICE ELECTRICAL. CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 "'MIV ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 REVIEWED .FOIE COMPLIANCE WITH NFPA 70 - NEC SEP 0 4 2015 City ofTukWila BUILDING DIVISION Project Title: Tenant Improvement for: BECU 'I'[JKWILA 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: 2ND FLOOR LIGHTING PLAN Designed By: RB Drawn By: MB Project No: 15110 Date: 08/05/2015 AUG 12 2015 PERMIT CENTER Sheet Number: E2.2 T- D E H; 'J1 K L M E49 GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H3 UNLESS OTHERWISE NOTED. 0 3RD FLOOR LIGHTING SCALE: 1/8" = 1'-0" RORTH PLAN S -06 � 70 -410) R E C E 0 CITY OF T'u"f"%WILA AUG 12 2015 PERMIT CENTER TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BEH EVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 REVIEWED 'IT FOR COMPLIANCE WI- NFPA 70 - NEC SEP 0 4 2015 - City of TuWla BUILDING DIVISIM Project Title: Tenant Improvement for: BECU TUKWILA Sheet Title: 3RD FLOOR LIGHTING PLAN Designed By: RB Drawn By: MB Project No: 15110 Date: 08/05/2015 Sheet Number: E2.3 tG TJ K, M•; N; 0 S 2 GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H4 UNLESS OTHERWISE NOTED. 4TH FLOOR LIGHT SCALE: 1/8" = 1'-0" NORTH ING PLAN W O ----(*10 R EC E 'V'C-- D CITY OF TUKWILA AUG 12 2015 PERMIT CENTER TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 Project Title: Tenant Improvement for: BECU TUKW'II.A Sheet Title: 4TH FLOOR LIGHTING PLAN Designed By: RB Drawn By: MB Project No: 15110 Date: 08/05/2015 Sheet Number: `A B C. - --T--- - - - D E ?FF G H J K, M N 0 p GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H5 UNLESS OTHERWISE NOTED. NORT 5TH FLOOR LIGHTING PLAN SCALE: 1/8" ---- C-3� O -08 RECEIVED CITY OF TUKWILA AUG 12 2015 PERMIT CENTER H Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 REVIEWED .Fb I COMPLIANCE WI NFPA 70 - NEC SEP 0 4 2015 City of TuWfla BUILDING DIVISH Project Title: Tenant Improvement for: BECU TUKWIL.A Sheet Title: 5TH FLOOR LIGHTING PLAN Sheet Number: GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H6 UNLESS OTHERWISE NOTED. 0 P 6TH FLOOR LIGHIT SCALE: 1 /8" = V-0" Q R S 0 4 O -08 --(10 r�e rE:CEI'JED CITY OF TUMI! A AUG 12 2015 PERMIT CENTER TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 $ s51 tt CASE ca ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 REVIEWED FOB-, COMPLIANCE WIT NFPA 70 - NFI SEP 0 4 7015 City Of 7ukwila BUILDING DIVI.,te,Rl E r. Project Title: Tenant Improvement for: BECU TUICWILA 12770 Gateway Dr. Tukwila, WA 98168 Sheet Number: GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H1A, H1B, OR L1 UNLESS OTHERWISE NOTED. FLAG NOTES EXISTING TO REMAIN MECHANICAL EQUIPMENT. SHOWN FOR CLARIFICATION —NO NEW WORK REQUIRED. R�> CONTROLS FOR EQUIPMENT FURNISHED BY DIVISION 23 CONTRACTOR. O � I l 1 ST FLOOR MECHANICAL CONNECTIONS PLAN SCALE: 1 /8" = 1'-0" RE.CE"lED CITY OF TUr*'%WIL A AUG 12 2015 PERMIT CENTER Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 PERMIT SET 8-10-15 Project Title: Tenant Improvement for: BECU TUI<WITa 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: 1ST FLOOR MECHANICAL CONNECTIONS PLAN Designed By: RB Drawn By: MB Project No: 15110 Date: 08/05/2015 Sheet Number: E3. 1 GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL XX UNLESS OTHERWISE NOTED. FLAG NOTES EXISTING TO REMAIN MECHANICAL EQUIPMENT. SHOWN FOR CLARIFICATION. —NO NEW WORK REQUIRED. CONTROLS FOR EQUIPMENT FURNISHED BY DIVISION 23 CONTRACTOR. 2 N D FLOOR MECHANICAL CONNECTIONS PLAN SCALE: 1/8" = 1'-0" AUG 12 2015 PERMIT CENTER 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 PERMIT SET 8-10-15 REVIEWED.FOR COMPLIANCE WITH NFPA 70 - NEC SEP 0 4 2015 Cify of-TuWla Project Title: Tenant Improvement for: BECU TUKWII.A 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: 2ND FLOOR MECHANICAL CONNECTIONS PLAN Designed By: RB Drawn By: MB Project No: 15110 Date: 08/05/2015 Sheet Number: E3.2 I i I I L � - — - - 38,40,42 F i I I I I I I i #8 _T I I I i I I - - - -- - �- - F - - -- - - - - - ®i FPTU-302 L -j 38,40.42 I I I I I I < ®. _ _.EP-JP-301 I I BREAKOUT 352 OPEN -- -� - - OFFtEe- - _-- H3-27 I I I rF F TIJ-320 - — - -- - --- - --- - - - - - --H3--2c i I I I r F ®� F TU-319 L _ J I I I I i CFPTU-318 r L_`_J F r ® FPTU-317 I I I L-_ I I - -1 - -- -r- - -- - ----T - - ,� - �- - -I - I I I I I (:K L M N R Li - 7— - - - =F- � L=1JJ III 1� ®, FPTU-338 -�- - - ---� - �— - - r---- - - - — - -I- -Fp - 04- --FPTU=305- -0 1 -- F 38,4042 38,40,42 ` -- F #10 H3-32 J I CONF ... L 3 44 OPEN #8 -- OFFICE 353 H3-38,40,42 _ - OFFICE CONE 356 355_j BREAKOU- T I I I I 309 I I-IALLWAY I I 354 I 1 F-9 '®n E- E I. 2 HP-301 3 � AL WAY E} IDF 3 4 - - 301 F — --- / =- - — / CONF 341 - -- - I Lac-8,10 ELEV _ LOBBY - \ 300 i (HALLWAY 331 I I HA-15 BREAKOUT H3-3�,39,41 334 #8 I J BREAKOUT 306 iFF F CONF I #1 305 -- ----- H3-3 STORAGE 310 r 2 EF3-01 /��i [2:>c Ili WELLNESS LC3 2 #8 1 1 #8 i I I I I i I OPEN OFFICE F1 330 F r - - I QUIET ROOM , 308 __ T 5 H3-36 r--� ®� FPTU-309 F I � I HI -26 OPEN OFFICE 323 ) i FPTU-310 F I i I L3d-6 % —HALLWAY 5-28 �..� 322 I I I BREAKOUT ®. EF3-03 2 324 I I I I I I r__-1 _ _ Fp�S�-314 - - i �_ 1 FPTU-313 --- - - - r - -TU-3-� - - - - — — - --- T_C---� 37,39,41 �— `'---J 7 39 41 �- `---_J 37 39 41 GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H3 UNLESS OTHERWISE NOTED. FLAG NOTES EXISTING TO REMAIN MECHANICAL EQUIPMENT. SHOWN FOR CLARIFICATION. —NO NEW WORK REQUIRED. R�> CONTROLS FOR EQUIPMENT FURNISHED BY DIVISION 23 CONTRACTOR. I I I PERMIT SET 8-10-15 REVIEWED FOR COMPLIANCE WITH NFPA70 M NEC SEP 0 4 2015 City of-TukWila BUILDING DIVISION Project Title: Tenant Improvement for: BECU TUKWII.A 12770 Gateway Dr. Tukwila, WA 98168 E3.3 M N 0 P Q R S 1 --U3, bM_ GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H4 UNLESS OTHERWISE NOTED. FLAG NOTES EXISTING TO REMAIN MECHANICAL EQUIPMENT. SHOWN FOR CLARIFICATION. —NO NEW WORK REQUIRED. CONTROLS FOR EQUIPMENT FURNISHED BY DIVISION 23 CONTRACTOR. -- — -- — H4-12 — -- — U FPTU-412A \ F V, # 10 FPTU-412 3 ,40.42 4TH FLOOR MECHANICAL CONNECTION SCALE: 1 /8" = 1'-0" TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 REVIEWED FOR I COMPLIANCE WITH NFPA 70 - NEC SEP 0 4 2015 City ofTukwila BUILDING DIVISION Project Title: Tenant Improvement for: BECU TUKWILA 12770 Gateway Dr. Tukwila, WA 98168 O OF Hi JKi Li (M N 0' I' II II III ---02 ----------------- (�3 I I I I I I 'I _T BR AKOUT 535 1 OFFICE L54 1 OFFICE H5_ _ OFFICE r4,2 532 GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H5 UNLESS OTHERWISE NOTED. FLAG NOTES EXISTING TO REMAIN MECHANICAL EQUIPMENT. SHOWN FOR CLARIFICATION. —NO NEW WORK REQUIRED. CONTROLS FOR EQUIPMENT FURNISHED BY DIVISION 23 CONTRACTOR. 5TH FLOOR MECHANICAL CONNECTION SCALE: 1 /8" = V-0" TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 REVIEWED .FOR i COMPLIANCE WITH I NFPA 70 - NEC SEP 0 4 2015 City ofTukWila BUILDING DIVISION Project Title: Tenant Improvement for: BECU TUKWILA Sheet Number: r,3.5 c D E F G M N �0 P Q R S BREAKOUT I I OFFICE OPEN 658 OFFICE OFFICE 1 613 OFFICE 611 612 652 03 - 610 FPTU-6 CFPTU-6 FPTU-604 0 CONF 37,39, IF I 1W�TFT�U_-6 116-19 — 0 F: C E -4m- - - - - �F --- � E-7 OFFICE 46F1 F CONIF 1#1 0 1 656 '5 F654:] W-9 H6-3 r3,3! H6-21 #10 146-17 #10 fill IF FPTU IFPTIJ-:6�0:7D 1 -618 F L - 0-- - tIF J OFFICE L FPTU-615 6-37,39.41 � FPTU-616 I F L 141 nF # 1 ot x'z L rl _)­7 �F ' __ 7 5�/ #10 10 37,39,41 IF HALLWAY F 10 #10 H6-15 H6 25,27,29 FPTU-62 11 M I _E 6-03 25,27,29 H6_ 63 COPY t L6-27 OFFICE648 F� I I � / I PTU-601 OPEN i (& c Lv/1 L___ 7,39,41 —QEFICE- F650 HALLWAY 7 OFFICE 647.. r H6-30 H6- 6 H6-38,40142 IF I FF, BREAKOUT IF FPTU-622 632 L 0 116-28 P Ll IF OE IF 63FFICF FPTU-613 CF L 3 1�� SM r 'I EF6-01 O L6-29 PANTRY L 62 7 1 LOUNGE OFFICE 615 OPEN OFFICE LqLo-j 4 FPTU-608 31,33,35 J1 OFFICE L_616 - 600 I / 7 H6-3 rsM L FPTU-626 / I ,=EF1E:0:2:< OFFICE 617 BOARDROOM FPTU-620 E 2=9 #10 � HP-61 a - I - - - � - - - - 146-34 #10 9 IF 61-8 L 0- 77 `7 619 r � T 10 LOUNGE L=8 L J I I F i r FPTU-610 38,40,42 GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H6 UNLESS OTHERWISE NOTED. 6TH FLOOR SCALE: 1/8" = V-0" MECHANICAL CONNECTIO 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 BECU TUKWILA 12770 Gateway Dr. Tukwila, WA 98168 FLAG NOTES - EXISTING TO REMAIN MECHANICAL EQUIPMENT. SHOWN FOR CLARIFICATION. —NO NEW WORK REQUIRED. 2 CONTROLS FOR EQUIPMENT FURNISHED BY DIVISION 23 CONTRACTOR. Sheet Number: E3.6 TE F G H J K -- ------- - - --d—VA, Ri L1_54 R T. I CASH iLl I LI T M N 0 P Q 7-- 'T1- - - - -i --i- r , --�^ 1- - - -- - ----i _._._T- _ 1 .._. ---r - ..I - - - -- -1 K 1 1 -- --I _. _ -K -- F 1701- J_ 2 �10F_11 rd PFFI�CEJ -4 J_ J_ d-1-1 ------ ------ -EMERGENCY EGRESS PATHWAY CALCULATIONS -1ST FLOOR RECEiVED CITY OF TUKWILA AUG 12 2015 PERMIT CENTER TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 H 9_4 CA S ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 REVIEWED -FOR COMPLIANCE WITH NFPA 70 - NEO SEP 0 4 2015 - City of TuWla BUILDING DIVISION Project Title: Tenant Improvement for: BECU T[JK\X/ILA 12770 Gateway Dr. Tukwila, WA 98168 Sheet Number: EMERGENCY EGRESS PATHWAY Illuminance (Fc) Average = 11.01 Maximum = 39.2 Minimum = 1.0 Avg/Min Ratio = 11.01 Max/Min Ratio = 39.20 EMERGENCY EGRESS PATHWAY CALCULATIONS PLAN - 2ND FLOOR SCALE: 1 /8" = V-0" --z 4., O RECEIVED CITY OF TUKWILA AUG 12 2015 PERMIT CENTER TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC SEP 0 4 2015 CitY of -Tulcw►ila BUILDING DIVISION Project Title: Tenant Improvement for: BECU TUICWII.A 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: 2ND FLOOR EMERGENCY EGRESS LIGHTING CALCULATIONS Designed By: RB Drawn By: MB Project No: 15110 Date: 08/05/2015 Sheet Number: EL2.2 fA B C D E F G H J K L M N 0 P Q R —T— EMERGENCY EGRESS PATHWAY 3RD FLOOR Illuminance (Fc) Average = 7.83 Maximum = 31.1 Minimum = 1.1 Avg/Min Ratio = 7.12 Max/Min Ratio = 28.27 NORTH EMERGENCY EGRESS LIGHTING CALCULATIONS PLAN - 3RD FLOOR dbl. EM SCALE: 1/8" = V-0" 1411W S 04 -0� -O 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 PERMIT SET 8-10-15 Project Title: Tenant Improvement for: BECU TUI{WILA E2.3 �C� D TE F 1 G EMERGENCY EGRESS PATHWAY -FLOOR 4 Illuminance (Fc) Average = 7.74 Maximum = 22.8 Minimum = 0.6 Avg/Min Ratio = 12.90 Max/Min Ratio = 38.00 H J M N 0 P EMERGENCY EGRESS LIGHTING CALCULATION PLAN - 4TH FLOOR SCALE: 1 /8" = V-0" C�3 4 �vJ -� 7 -�8 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 PERMIT SET 8-10-15 Project Title: Tenant Improvement for: BECU TUKW1LA 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: Ct 4TH FLOOR 0 bq EMERGENCY EGRESS LIGHTING PLAN RECE'SVE-D CITY OF T' ?%V1' l L A Designed By: RB Drawn By: MB AUG 12 2015 Project No: 15110 PERMIT CENTER Date: 08/05/2015 Sheet Number: A B C D TE F tG H TJ K L M N 0 P Q R S I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ► I I I I I I I I I I I I I I I I I I I I I I .7 1.4 .8 -t5. 7 T4.7 12.9 10.9 t.1 1.7 1.5 ti.0 t!. 3. 4.5 %.a 3.6 6.6 t.1 10.5 3.8 513 17. 17.6 16.8 14.7 12.3 10.2 tl.1 tl. t/.4 11.0 1.1 10.7 3.3 4.6 15.7 15.9 15.9 15.0 13.4 %.4 CONF 1.6 t1.5 (03. 4.7 j :3 t/.l 6.6 11.4 14. 17 19. 9.4 0.8 16.3 13.7 1.3 6. t. .4 1.6 11.4615.9 17 1 17.5 7.5 16.4 14.9 10.7 5V� L3 L3 L3 2 3. 3.9 4.5 fll.4 3.1 1f.1 10.1 13.6 17. t20 t! 2.0 11. 10.2 15.5 12.5 OA 5. tJ 0 tJ.2 tJ. 11.0 12.2 16. 10.3 19 .5 19.8 30.2 16.7 11. CONF is I I �y�J( / I T� t1.6 3. tJ.9 11 %0.9 17 4 12.7 1 7 18.5 13. I ® En t- ---� �3) El • • L G T AM 3.2 4. 6.2 t1.5 5 5 10.0 10. 11.2 12 0 15.4 19. '12 *1 J15.0 t24. t11.5 10 1 15.7 3.1 12 9 1 .. -113.00 7�13.3 14.1 1 .7 10. 10.6 t2 7 t11.7 1a 2 18.1 13. � � - 6 R M %.1 3.7 Q5 tJ. 0 1 "�'�"2.8 13.4 14.1 Q19 t21 t2 (" " �3.3o(tjRFI`y8.3 .4.4 14 1 IDS a 1�5.0 16.0 17.1 t' s 11.1 9.1 17.1 FFICE / 4.6 t/.3 tJ.7 12 2 4 15. 16.0 15.9 15.0 15.0 15.3 17 6 19 41, t21.3 tz0. ��p 1 .0 17.9 .6.4 17 0 10.1 18.9 10.7 17.8 17.5 18.0 10.5 10.6 18.4 17.8 16.7 19.9 12.0 L - - - - - - /A' / �- _ -3.2 11.4:T1 19.9 i9. 8.1 6 5 T6.1 6 18.2 �0-. 17,8 7 5 7.7 0 5 22.3 1�2.3 1�0.6 .1 8.2 17 8 5.1 �13.9 T12.6 .9 .8 6. -t3.3 .6 �5.1 t1.3 1.q - - +.1 1.7 -i.6 �0 tl. .4�4.1 4.2 4.4 �4.7 6.6 .5 ,2 4.3 tl 7 1.9 1.1 ff L.1, �- 1 6.5 1.6 13.0 16 7 9 t1 2.2 31.4 19.3 17.2 15.7 15 15 1 16.5 16.5 17.4 17.3 19.0 19.7 t12.4 t1 t24.9 t24.5 t11.9 19.6 17. 16.2 1! .0 1 13.3 12.4 11.2 tJ. .0 6. 4.2 .6 .3 1.9 1.6 t1.6 t1.6 q t1.1 1.7 1.9 1.7 b.T2 .6 10.0 13.0 12.5 i2.4 �g.4 14.0 14. 14.0 3.0 i E2 5.G t1.6 1.3 .8 5,8 10.9 18 1 1 t1 t�•�• �3.3 51.2 18.2 14 14 1 5.2 16.1 17,0 0.7 t13.5 ? 6.6 t13.6 t10.8 1 .7 1d.1 1 11,0 10.1 6, .1 6. .1 4.S 14.0 5.g .1 ,0 t1.9 i. 4 6.8 0.0 S4 7 pn� _.may 4 1. 4 4 ^ 'I t, LJ- Ll" S 9 .9 p+r 7 0.3 14' S 11 0 7.2 11._ .0 il,j2 1.9 / B (//t,0.912.3 12 1 4.8 7.1 {c0 1 3.3 2, t21117 0.6 10 0 6.5 5.$ 15 1 5.6 S. 16.2 17 1 8.4 0.2 32 6 11 5.8 5.7 t23.1 t1 .5 0. 6.0 14.6 1 2.6 1.6 10.5 5. 1.4 6. 3./ t 4.2 5.7 5. 5.2 5 3.5 t2.1 1.6 1.9 5.2 6.7 .9 17.1 122.0 3.1 00.1 t)3 ty1"1( tl 16.9 19.1 1 .7 t/.l t3t 1.9 I • 51 3 1 / .9 10.6 T0-i0.6 6.B 4--t2.0-1 0 .6 4.4 1.3 13.5 15.8 16.5 15 19.7 17 16Lai.0 17 5 t12.1 t2 g 11.a 3! .0 6. �i.7 4,d 3.9 t1.6 t2, ,6 .0 3.1 A R ._.i.9 5.1 1.9 10.6 16.5 7 15.7 11. B 4. 9 t1.7 1.5 4.0 6.0 13.6 10.2 110.4 t10. 8 15.9 14.9 14.1 5. 1 17.3 10.3 10.0 17.7 OPEN 17.3 17. 10 19.7 19.4 19. 17.9 17.7 16.8 7.7 18 t20.3 11.0 t11.3 t20.5 19.3 19. 10.2 17.0 17.0 16.3 14.0 13.4 10.0 . 6 t/. 6.2 .6 4.0 5.5 5.3 5.1 1.0 1.3 2 1.0 5.8 .0 10.1 13.1 14.7 14. p ��1 .0 16. 17.0 14. 5 6. 3 6.2 1.1 1.8 CONF ��•`+� E2 513 10.6 18.2 .7 �18.3 13.3 6.1 5.7 .7 .5 13.3 19.8 �'i.8 t22,8 17.8 14.3 13.0 9 14,3 15.1 1g.0 15. 7.5 19.2 tll 1'2. 2.2 1.8 19.8 10.2 C011.0 16 6 17. B.0 8.7 10.1 18.7 19.1 1 .7 1 .6 19.3 B.7 7.2 15.5 12.4 6.2 6.4 4.7 4.1 3.5 t3.3 t3.0 1'.4 t/.5 12.6 .4 13.4 10.2 4.7 t1.9 1.2 t1.5 4.8 1+.0 14.5 15.5 16.4 13.9 .5 10.3 0.1 11.3 2.3 1 .8 14.0 1" 3 18.1 t11.2 33 4.9 t14.2 $1.0 1.0.0 1.6.1 4 8 11 1 15.4 16.1 17.1 17.9 i0.4 31.7 t1 9 31.2 19.5 17.5 13.8 .2 6.4 t•.5 4.7 4. .2. - - - _- - ----_ ,g q t4,2 3.7 6.4 1.5 1.5 1.5 6.9 y tl 1T_ ►Jy 18.4 52. 1+5 1'6.7 3s, 122.5 19 2 16.5 4 2 13 8 1 14.1 14. 15.7 1.7,3 t10. t11.8 3. 6 32.6 t10 9 18.6 15.0 .8 ' 6.7 6.8 4.9 4. .2 STORAGE .8 '.6 6.6 6.3 10.2 11.4 11.8 11.7 10. gA t7.5 6.3 ti.0 14.0 il t TACONF O / / 6.2 .8 11.3 EA .0 .8 19.3 t13. 35 7.2 fi.0 32.6 19.3 6.8 4 5 14 ^ 1 1.5 5.1 16.0 17.6 .0. .1 .0 t1 0 1 .2..5 0.7 10.d 14.8 .0 6.9 6.0 6.1 4.3 3.7 0 T/ t1.0 51O 5I 1 .a•3 1f.6 11.6 16.3 16.7 16.3 1 T..1 1 .0 t7.6 6.7 t3.8 .1 4.5 QS 6,0 5 R ,7 _ 16 35.3 t12.5 19.2 4 9 16 1 16.8 17.3 17.5 3 ,6 t11 5 19.6 17.2 54.4 J5 t7.0 6.2 3 4.5 3.8 ,7m t2.0 R R / / 9 E2�• ® ® I WE E MESS 1 r.o 10.2 t3.a G%� 19.1 20.1 19.e 17. ta.e 1 .B b.o i.a *�4 4.4 6 /i nn rNI// 4� . 512 5 2 t4.7 1.7 6.7 0.9 13.6 7:\�7-�20.� t Y+��f, t17 t10. t11.5 10 .9 19 10. .1 19.9 1 .6 1 .1 19. .B 15.0 12.6 9 t7.0 6.2 6.4 U EA; 2 6 t1 CONF STORAGE .fi .B 11.1 15.0 18.2 17..4 52.5 32.1 19. 16.5 13.3 10.1 11.0 6.1 t 0 .1 6.3 .3 10.1 12.9 15.7 t10 1 4 1 56.8 59. 50 t18.2 54.7 t12. 30.2 10 I 19.5 .0.2 53.2 54,9 t15.8 55.0 33.2 t1 .7 19, 17.0 17,1 16.1 15.3 14.4 12,6 11.5 -. t1,3 6.s S,8 4.91 4.1 5.3 t1,6 t1,0 51 1 9 .9 11,1 14.8 18.2 A1.1.3 t22,7 52.3 t10. 17,2 14.3 11,0 6,9 6.9 6.B 4.8 --- J t - 6 1.1 1133�.0 15.6 10.0 13.2 t18. 6 31.1 13.0 50.9 t18.0 t1.4.1 t10.1 10.6 17.1 1.9.0 1.9 $..6. 6 t19.6 50.9 t30. 3 16.4 t13.2 19.0 16.0 14.5 13 A L12W A Y 4 10.4 4.6 .7 6.2 5.7 X t'.0 6.2 3.3 4.4 ti .5 t1.7 t-oMttiWAV.2 1.1 1.2. 1.2. 1.1 1.2 1.3 1.3 1.4 1.4 1.4 1.5 1.5 1.6 1.7 1.0 t1.4 ti.0 ti .5 .0 X 10. �14.1 t10.2 t 1 .6 1 q 19.7 14.2. 11.6 .9 6.7 ti.6 .4 17.z t9.e t11.9 47.1 t27.6 t19.1 t27.1 t23.s 1:0.3 15.e �.,14$/�$I S SSU74.8 13.G 15.7 8,5 t12.3 t16.1 t17,2 tz7,2 33.8 t10.3 16,4 13.6 �.W( 4 10.t 9 .g 0 6.4 t/ 8 6.7 8 t1.1 6.4 4 3.0 1.2 1.7 1 1.0 1.1 2 2 1.2 1.3 3 1.4 1.4 1.5 5 1.5 1.6 1.8 0 1.4 '.6 6.0 6 .2 4 11.3 18.9 18 9 1B.4 14.6 12.1 10. .0 1.7 6. _E2 E2 - - - 6 -16.7 0.2 0.6 .0.9 .0.4 1.9 3.4 3.>i .9 .OAT �.0 6 .9 .9.8 9.6 7.0 4.0 L . .7 .2 -.0 .d .0 4.9 ".B .1 6.3 '.3 .3 10.2 -12.3 14.0 15.3 15.7 5. 4.7 13.5 12.7 11.3 10.3 ti.9 7. / 16. ®. 7 30.7 19.3 18.1. 11.5 17.3 ,1 10.1 11.6 10.9 10.1 t. .2 6.8 1t.3 t3.9 11.4 12.9 13.6 14. 14.7 15.6 15.1 14.6 13.6 11.U1 / / C WIR- N E P I -I 7.7 gRy� 1.8 10.9 14.2 13.4 12.4 6. fpR20 �•2 3.6 6.7 3.0 10.2 11 5 13. 16.9 18.0 17. 7.4 15.2 1 8 .12.0 5.5 14.9 3.5 1i.7 V E I.7 q.9 i8.4 17.4 16.2 10 CONF STOF T�AAG .7 6.1 6.1 6.3 .B 11 4 13. 6. 19,1 t21,1 1 1.0 17.9 15.4 3.2 $ #1 E 517 --- ^c 6.2. 0 0.1 t1.5 .1 6.9 4.4 3.3 2.0 7.4 32.8 t..1.8 10.4 14 51 .fi 4.B 6.6 %.6 1.7 t1.2. 11.2. 14, 17.4 10.7 $4.0 t14.6 t14.6 Si.5 18.0 5.7 0.3 t3.2 14.0 11.0 t16.5 t15,5 t13.9 1 S / / 7 15,0 15.9 1.9 A 1.0 4.5 11.4 14.0 'OPEMO.3 'N.4 44.0 14.0 11.1 17.6 5.3 / t1.0 1t.4 L.9 / �' 15.7 12.9 3 7.3 0 I j.8 6.2 6.z 3.4 1.8 11 7 14. f ICE .8 t12.-1 3.1 t1.0.3 17.0 14.1 I i �eE�A1bR� 517 HA LWAY � t A 1' 7 14,1 5.3 13.1 �.3 4.3 1, 4 Cyll.•r�^' 5.2.7 t19 t27 W �p ,0 1_41,9 11.0 12 5 13. 7. 19.6 19. - 9.7 17.8 14ql... ..L4 Jl 1% LamT r- - -- CONFIG -� - - 116.4 12 69 1. .2E42.0t1B.9ttCONEA CWA. ,6.5 10.2 11.6 12.7 13.8 14. 15.6 1a.1 i^ + is o ic.3 14.7 121+.� F A L, AY15.4 sl.s �.9 4. EXIST �2.9 1851- q/S�T9QF t12.s 528 �j �7- p �_ 3 3 10.8 12.7 14,8 15.7 16.3 15. 15.5 14.8 14.6 13.9 13.2 12.3 10.6 0./ 6.9 t3.5 11.7 6,4 T f.9 f 0 4 544 LOBBY I II 1 - 1 BREAKOUT / 14.0 6.3 14.2 10.6 6.3 / 541 0.9 15.6 !� D9 9 18.6 1 CM F �A \V('�'}� _ .5$ 4.5 L 7,2 18,5 18 8 17. 14.6 13.1 11.7 4.8 .0 .2 y.2 10.3 10.951,f�4 .e 6.1 6.4 SM� I� IIpY,4 1t.e 16.1 15.5 14.3 10 ` E 11_J 2 �� -- -� .3 10.2 13.6 9.2 0.4 t10 5 19. 6. 14,5 12.3 10.7 ,/ 3,9 ,2 .3 t/.7 1 .0 13. 13. BREA T 1.9 544 ��((�y]� y / O$ I 15.0 7.1 14.5 4 ,0 / 71'3 .4 EL.1 12..2. 11.6 10.7 t/. tS�.y L2 .5 10. 14.3 1-1.5 t10.1 31 .7 '1.8 t10.1 17.5 14.7 12.0 10.1 t.6 6-0 .6 .7 �J.9 12.2 .2 6.9 .9 _ 6 --- 1 -1�7 U S A� / 1 A 1 17.6 � fJ`7 16.6 q. � �2 4,8 6.8 4.3 3.0 3.2 3, 7,9 11,2 14.7 17.9 /40.7 t12.1 t12.1 i0.4 17.6 14.7 11.8 71.9 6.3 1.7 .3 1.4 4.6 11 13. 3.4 11.1 6. COPY jI X 1 17.3 1.5 18.4 -( 3.4 t,l 6.3 4. 5 2 5 5.9 11.0 14.3 t10.1 11.6 t21 5 30. 14.8 11.8 6.9 1.5 l 1.8 10. 2 12.2 1.5 6.4 7777 $.2 rrp��1+.''1( t2,3 ?.2 1.8 1,7 1,5 1.5 s1. i 1. �^y1.fi 1.8 -t1.t ^-.4�^ t2.8 t3.2 y 3.6 3.8c�4.0 3t-.0 .3(+ .2 t1 9 .2�. .3 4..7 8.7 ^8.88 7-:6 '17 _ - / / / - c -. .6 4, 6c 1'. '.7 4.4 - -"'� I ""�� X1 -T- --.1 10,7 13.2 8.3 9.7 19 8 B. "14,3 �.0 10.i 1.G '.9 .0 t1.6 11.4 J.7 1't. 6.0 1 8 t�.2 t3.3 4.0 @3$ 1.0 3.6 ti.l @7 1.4 t1.2 1.2 @3 t1.4 1.8 1.1 (POJ 4.5 i'.5 6.0 tZCS 6.0 6.5 6.3I &4 3.0 4.5 4.5 @6J �.. i2!910f 6 �7.0 19.4 t10.0 t13.2 16.9 18.3 18.2 '24.4 t10.0 15.5 11.8 11.0 10.7 13.5 �6.4 t10.0 t22.9 t12.9 11.2 16.9 12.5 1.7 6.0 @2$ 3.0 1-3 i.0 @O t1.1 �.l -1.?S@ 14.2 3,6 �S �HAL HALLWAY. OS 1.3 1.3 1.3 &$ �.3 1.3 1.4 (®1 1.7 5.319t �/®��� S� 1 � J � I � �fi �1-/ �!7 6.3 6.5 6.4 6.2 6.3 6.9 2 11.9 13.9 15.9 17.5 17.6 17. 15.9 19.7 12.6 10.9 3.9 3.9 'I.0 5 6.7 6.9 '!.6 1.3 S.2 6.7 2 t'.2 1.3 6.4 t1.0 6.3 6.8 4.5 5.9 5.3 i.l 5.0 3.0 5.2 5.7 4.3 .3 1.5 t1.8 5.1 t3.8 10.4 1.9 to 6.0 tf,l 6.2 6.9 6.5 1'I.3 10.0 3.2 16.0 18.6 t13.3 t16.6 51.6 )3.0 53. 19.1 t14.0 19.2 14.7 13.6 13.0 15.8 6.7 12.'� 5.4 t15.4 t13.7 18.1 13. 2 6./ 5.9 t2.7 3.1 1.9 1.8 1.9 .3 t1.6 5.1 5.0 t2.8 t2.6 tl.l 1I1 :-3 .2 1.2 1.2 1.2 1.2 1.2 .2 1,2 1.2 1.4 1.6 5.4 6.g t7.6 ti.l t1.6 tJ.7 5.9 tJ.l 1t.3 3.2 .2 5.2 10.1 11.7 12.8 14.3 15.2 1S. 15.7 14.7 I4.0 12.2 10.6 1'I.8 t/.3 6.0 F.8 r'.9 S.g F.3 F. -� .5 5 1.3 .9 ti.7 1.8 t/.0 .1 4.9 4.2 .7 5.6 5.7 1. 9 4.6 6.3 0 %.3 0.6 12.2 13.5 1.3 13.4 12. 7 1 .5 1.1 .7 t7.0 t/,3 0 5.4 1.4 1 .2 17.4 2.0 16.1 51.2 13.4 53. 7 30.5 1 .1 10.6 5.6 14.1 13.3 14.7 7.3 19.7 1 .6 12.6 t21.4 .4 to 11.4 12.7 11.3 0.0 .6 6.0I 1.9 4.3CD .3 'A 5 v 3 6.3 1.1 10.3 12.tD 7.1 .A5 1 .3Q 13.3 11.1 t.IC �.y�� .8 2e 5 2 1. 13.5 16.6 Ia.Q) 7.9 .2 5 .�� 13.9 19.5 15.� 2.2 ./6 Ij .8'r1� 16.3 16.1 14.8 B6 10.0 12p. a 2.5 0.9 .6 6.7 1.7 1.1 1i.1 .2 62 t7.3 9.4 11.8 15.0 18.0 0.0 n 12 ).3 18.9 15.5 12.7 10.SSC.00lI .8 94 S8 13.4 16.1 19.5 12.8 6.4 .4 i.11 166.7U 12.8 18.8 19.6 12.9 1.5 Al 1.4 111J.6LJ 12.2 11.8 11.0 t L .3 6 16 0 I2.5 1.0 .8 1.0 6.3 .8 .0 .2 1 4 it.4 .6 13.3 6.6 0,3 2.3 .1 : .0 1. 5 14.2 1.8 0.0 .9 .0 11.6 1.8 .7 16.1 =is.i .9 tl5.6 .1 18.2 4.7 2.6 1.0 .3 B,9 .4 .2 11.6[3REA' '1/.B 5_2 b812 9 I1.6 I0.3 3.2 1.3 1_1 .1 5 .1 13.7 1.9 .8 t1 1 i4.7 1.8 .8 i .3 I5.03.3 .9 t1 t .0 18.5 2.1 .0a lk2.6 t1.9 t1.1 t 4-6- - .2I 1.7 1.2 5.4 la .2 I., 1 .3 11.6 �2.7 14.0 16.S 19.1 11.0 5 1 .6 10. 17.5 14.7 13.6 12.7 3.5 .1 1 14.9 15.4 16.4 17.5 19.4 1.3 .7 1 .� 12.1 19.8 17.5 1.5.1 14.3 3.6 .4 � .3 10.0 6.9 6.0 t/.0 6.4 10. 12.3 12.9 13.1 12.3 11.7 10.0 ti.l .7 6.8 .5 10.4 11.5 3.1 14.2 15. 16.3 16.6 6.1 14.3 12.7 .9 %.1 .5 3.7 1.2 i.9 4.5 4.2 11.40"" 16.1 6. 15.4 14.3 11.8 10 3.9 .0 .7 CJ 12.2 14.3 16 8.3 18.8 9.2 7. © 12.1 1.l tl. �J 4.9 .4 5.9 5.5 4 II1 17 7 11. o.a 13.3 16.3 13.9 4.3 a 77�� 1 :d' .8 10.7 12.4 14.6 17.3 19.6 50.9 try3 9.9 17.2 7 13.3 0.0 .5 .7 4.8 1 5 3.6 .2 14. 9. 10.0 18.2 14,9 2,2 0.9 10.0 .9 10,1 1.0 2.7 11.3 8. 11.2 12.6 3.5 1.6 18.9 4.9 10.7 1.1 *.8 4.8 9 1.5 14, t10.2 18.5 11.0 11.5 1.4 2.9 15.1 11.8 2.6 4.8 10,5 1,1 6.6 1.7 .8 .4 15.I � 19.5 10.44 10.9 19.6 18.2 16.0 14.1 3.6 13.2 3.1 3.0 12.9 13.7 15.2 17. 19,5 10.7 1.3 9.7 17.3 13.7 10.0 1.6 5.4 5. 2 l( .8 1.0 10.5 3.5 .3 1 .1� 3.2 14.1 14.6�'l 8.0 .5 11.2 16.9 14.5 15.� 6.8 1.4 1 .6 16.6 16.2 16.L41J 8.6 .6 4-18.2 18.5 16.314J 6.6 -.3 .0 10.7 4.3 13.2 6.7 6.5 4.8 4.6 4.9 6.2 */.3 11.3 10.5 11.6 2.0 10.7 10.2 t7.6 6.6 4.9 4.3 4.0 4.0 4.7 4.8 5,6 6,6 %-0 1.3 10.5 11.0 11.1 10.1 4.9 1.4 12.5 13. 17.8 18.1 18.6 18.3 17.2 17.1 15. .4 16.0 5.9 5.24 13.9 14.4 15 8 17.5 7.9 6,8 6 12.3 1.7 J.2 .0 .1 10.2 2.2 14.9 16.8 .9 17.8 16.8 '.6 14.3 4.4 14,7 15.4 .1 15.9 1s. 1 .6 13.9 5.4 16.9 15.4 .1 t11.1 �0.4 1 .7 17.3 6.0 15.1 16.0 .6 17. 16.9 4.. 17.0 7.0 16.8 19.9 .6 7.1 15.0 1 .9 11.2 ti.6 6.1 t/.0 1.5 6.6 '1.2 1.6 10.7 13.1 15.8 17.2 8.3 17.1 1.5.5 12.7 10.0 t.1 6.4 %.1 t.9 4.3 6.9 6.0 4.5 11.6 13.6 5.7 16.7 16.9 15.9 14.4 14.1 14.1 15. 15.9 16.1 16.2 16.0 15.9 16.3 16.9 8.1 18.9 8.5 18.2 16.7 5.4 14,5 14, 14.6 14.6 4.4 13.2 11.6�., t/.2 '11u�4 0 .4 11.5 4.2 17.5 19.6 f ,9 t10.2 18.8 .2 14.3 2.9 12.8 12.8 .4 1].7 13.9 1 .0 13.7 6.8 18.8 12.2 4 13.6 2.7 1 .6 17.2 1 4.9 13.8 13.6 14.3 15.1 1".0 17.5 8.6 121.3 12.5 19.8 17.1 1 .9 12.7 U.0 11.4 6.4 1.1 6,7 te.5 12.9 6.1 19.1 10.9 .1 t20.4 18.7 4.9 12.1 .6 t/.9 t1.6 .4 t1.8 6.5 .8 11.6 4.2 t16.7 119.2 .2 t20.4 18.8 6.9 14.0 4.4 13.8 14.5 14.6 15.3 5.4 17.4 18.3 0.5 11.4 64 10.2 17.9 5.7 13.7 12.6 12.2 11.8 .4 10.7 1.2 6.1 6.0 O. 12.6 15.6 2.] .8 t2 .2 _ :.a i4.6 i2. 0.8 .7 i .0 2.2 13.3 16. 4.1 .6 4 .2 1.2 17.9 4.� 1.6 .4 1 .7 7.9 16.2 9. 9.9 .7 2 6.9 14.6 2. .7 4.5 2,0 14,7 8. 9.0 .5 3.9 7.9 14.1 1. .l .8 .3 1.7 17.2 6 22.0 .4 J. 9.5 17,1 4 13.7 ,7 3. 4.7 16.9 9 8 t1 J.5 ].5 2. 6.7 13.8 11. 10.4 11.5 .7 /.B 6.9 S.8 9.8 �4.4 OPEN /1^'��1�^♦.7��I0. 12.2 19.9 18.6 1.2 .6 2.1 19.9 .9 I7.9 11.3 .7 .3 1 tj 6 4.9 11.1 12.2 15.7 19.2 2.7 .2 t1 .'1 3.2 I9.8 16.5 I7.2 1.1 0.0 8 1 11.0 12.0 14.9 18.1 t11.0 3.8 .1 .9 19.7 17.1 15.5 13.6 2.7 1.7 1.3 1.6 12.8 15.0 18.0 1.5 3.4 .8 ].5 1.4 IOf FII� 13.z 1.0 1. .00 R 1.4 12.1 13.0 16.1 18.8 1.4 .8 3.1 t11.7 19.3 17.2 15.1 14. 3.9 .8 3.8 14.1 14.0 16.6 10.8 1.0 t12.8 2.6 1.5 18.6 15.7 12.6 10. 5. 3.0 .1 .SL4" 4.6 4.3 53� OF ICE .8 11.7 14.2 17.8 0.2 .6 t1 .9 18.7 5.7 12.2 10.1 6.9 .9 6 6 1 6.6 5.7 11.2 14.7 18.1 1.5 .7 t2 .2 1.6 18.3 15.1 11.8 1.8 .7 3 6 9 5.3 10.5 13.4 2.3 .7 1.3 15.8 3.8 J.9 15.5 2.5 .8 8.1 15.1 3. .0 5 3.5 14.2 0.7 .9 8.8 17.2 14.6 .6 9.8 16.4 11.5 1.3 4.6 11.5 E.3�.7 1.6 .7 1.0 -- -- T -- -T- ---- - .2 ^ 0.8 13.3 16.5 18.6 19.8 9f 1 1 4.2 1.2 .2 t/.8 tl.] tl l.9 .1 10.4 13.7 16.'/ �11.8 2�1.J 9.8 16.8 17.8 10.9 5 1 11.0 i/.4 -iJ.9 T1.9 10.9 ].8 15.8 8.5 .5 f.9 17.9 1 .9 6.'1 6.0 '�1 6.9 7. 6.9 15.J 4.6 4.7 5.9 i8.0 9.2 0.2 9.7 8.1 7.7 �8 5.9 -�5.1 6. 6.2 J S.6 5.7 4.1 9.3 4.6 16. 7 18.7 7.3 7 - -- - r--'- _. 1 .5 8.7 9.0 -1 .2 6.7 16. 6.6 6.6 6.5 �5.7 5.8 15.1 16.9 6.9 18.2 7,7 6.0 14.7 2.2 10.0 .0 .7 �.7 9.9 9.2 UO .S t/.0 t7,4 t1.1 11.2 12.9 4.8 .9 .9 14.6 14.8 15.8 17.2 10.7 9.8 0. 17.8 15.9 14.0 14.7 15.7 6.3 6.9 6.4 15.5 15.2 14.6 16.1 17.7 8. 9,2 8.617.3 15.9 14.4 14.1 14.1 5.1 5.6 5.9 16.0 15.5 16.3 16.9 17. 18.4 B.5 8.4 17.4 16.4 15.4 14.7 5.0 15,0 4.S 3.6 11.6 10.0 %.1 6.6 4.8 1 5.�� J'4 �119.4 0 t 15 ��.J 3.6 6.0 t/.0 6.7 6 1.4 17.3 16.9 10.t11 2.q . 19. 16.6 13.9 17. 1] 3.] J. 13. 19.2 14.2 17. 19 1. 0. 19. 16.9 1q.6 12, 12 2.2 3. 13. 1q.2 16.1 17. 19 t10.1 0... 18. 17.7 14.4 13. 12.1 0. /.9 6.8 ,1.7 4.1 4 a 4.5 4,8 11.6 .7 t/.6 6,6 0 .5 10.6 1 .0 15.1 8.3 t11.5 t13.9 .7 t13.7 110.7 7.3 13.9 2.0 11.2 11.0 .0 11.0 11.0 2.4 13.7 7.1 t10.2 t12.2 .6 12.4 t10.6 7.S 14.5 12.2 10.7 0.4 9 10.7 11.5 2.5 14.9 7.7 19.5 i1.0 .1 il.l 19.7 7.S 14.5 11.9 0.7 tJ.'1 .8 6.1 t/.0 .0 6.1 .7 .2 I I I I I i I I110. I I .5 3.7 *J.9 4,4 ;.3 1.9 6.7 f 3 1.9 t1.3 1 .8 14.2 7.4 10.9 43.3 .1 13.1 10.1 16.6 12.9 1C.9 1.7 1.3 2 to 3.s 11.3 12.9 16.5 15.7 11.7 .1 11.8 t20.0 6.7 13.8 11.1 t3.5 .8 .8 tl.l 10.1 1.4 13.9 16.9 18.9 10.6 .7 10.7 10.7 16.7 13.4 10.7 .1 1<.D .2 6.9 %.7 4.-1 4.6 t.2 .9 303.6 .3 9 .4 12.6 1.4 31.% SB.7 15.7 12.0 .0 8 .B 11.7 14.8 18.2 t10. .4 5.6 12.9 .7 .s 0.0 12.2 15.4 17. 19.2 .3 19.3 17.5 15.4 5 3.5 f.9 6.9 .1 3.3 19:6 1.2 6 ��7•--'^-111��3.1 tJ.S .9 .9 .0 ,6 .l T1.J 10.5 17.9 .8 B.1 B. 18.1 16.0 1J.3 10.6 T1.6 '1.0 .8 t.0 6.5 10.2 12.5 15.4 16. 8.1 7,2 .8 13.5 10.9 t1.1 ,4 .8 .5 .7 .5 6.6 10.6 13.0 14. 16.5 16.7 16.7 15.1 10 �/.2 1.4 6 9 •7 t.l 3.5 b.6 .4 .9 6.1 'I.4 t.7 11.6 14.0 5.3 5.2 13.2 11.2 4.8 t1_6 6.6 .3 .0 �.2 6.5 t1.6 3_0 11.3 13.2 144. �5.7 4.5 13.4 11.2 tJ.4 1/.6 6.6 .0 .9 .1 6_8 t/.8 t1.5 11.4 2. 4.2 14.5 14.6 13.1 3. JiJ I I I I I I I I I I I I I EMERGENCY EGRESS 5TH FLOOR Illuminance (Fc) Average = 12.72 Maximum = 33.7 Minimum = 1.0 Avg/Min Ratio = 12.72 Max/Min Ratio = 33.70 IvI • � I.I �I • I■� 'c,�r,�_'i�■' I EMERGENCY EGRESS LIGHTING CALCULATIONS PLAN - 5TH FLOOR SCALE: 1/8" = V-0" PERMIT SET 8-10-15 REVIEWED .FC H COMPLIANCE WITH NFPA 70 - NEC SEP 04 2015 i City of'iukw�li a BUILDING DIVISION Project Title: Tenant Improvement for: BECU TUKWILA 12770 Gateway Dr. Tukwila, WA 98168 Sheet Title: 5TH FLOOR EMERGENCY EGRESS LIGHTING CALCULATIONS PLAN RECE1VED MOMEM CITY OF TUKWIL.A Designed By: RB AUG 12 2015 Drawn By: MB Project No: 15110 PERMIT CENTER Date: 08/05/2015 Sheet Number: I C' D, TE F, Gl H) J K i EMERGENCY PATHWAY 6TH FLOOR Illuminance (Fc) Average = 9.33 Maximum = 34.2 Minimum = 1.0 Avg/Min Ratio = 9.33 Max/Min Ratio = 34.20 0 P Q I I � � I I I I EMERGENCY EGRESS LIGHTING CALCULATIONS PLAN - 6TH FLOOR NORTH ofth IM9, 4`1 --�:7D -----CGO rECEIVED CITY OF TUKWILA AUG 12 2015 PERMIT CENTER 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402-9400 Fax:425-402-9402 PERMIT SET 8-10-15 REVIEWEu 6 uo COMPLIANCE WITH NFPA 70 - Ni r SEP 0 4 2015 r i City ®f.Tub*i BUILDING DIVIS;C ); Project Title: Tenant Improvement for: BECU TUKWII.A 12770 Gateway Dr. Tukwila, WA 98168 Sheet Number: EL2.6