Permit EL15-0731 - TEAVANA - PANEL, TRANSFORMER AND LIGHTING
TEAVANA 856 SOUTHCENTER MAIL EL15-0731 i City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 9202470010 Address: 856 SOUTHCENTER MALL Project Name: TEAVANA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940, CARLSBAD, WA, 92013 Contact Person: Name: ANDY PAROLINE Address: 3617 SW CHARLESTOWN ST, SEATTLE, WA, 98126 Contractor: Name: ORCA ELECTRICAL CONTRACTORS Address: 2704171 ST SE, BOTHELL, WA, 98012 License No: ORCAEEC944NU Lender: Name: Address: DESCRIPTION OF WORK: Permit Number: EL15-0731 Issue Date: 9/21/2015 Permit Expires On: 3/19/2016 Phone: (206) 719-0339 Phone: (425) 487-2636 Expiration Date: 9/16/2016 ADDING PANEL, TRANSFORMER, TIME CLOCK AND LIGHTING CONTACTORS WITH OCCUPANCY SENSORS, LOW VOLTAGE TRACK LIGHTING, LED LIGHTS AND EQUIPMENT Valuation of single family: $0.00 Fees Collected: $537.42 Valuation of mf/comm: $18,000.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 C Permit Center Authorized Signature: Date: —� i I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signat Print r Date: �i / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB t CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htti)://www.TukwilaWA.IZov Electrical Permit No. F i, 1, 6Z I Project No. Date Application Accepted: — e/ Date Application Expires: if ELECTRICAL PERMIT APPLICATION use Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: Site Address: 856 Southcenter Mall Suite Number: 1155 Floor: Tenant Name: Teavana New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: Westfield Address: 2800 Southcenter Mall City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Andy Paroline Address: 617 SW CHARLESTOWN ST City: Seattle State: WA Zip: 98126 Phone: (206) 719-0339 Fax: Email: ELECTRICAL CONTRACTOR INFORMATION Company Name: Orca Electrical Contractors LLC Address: 2704 171 ST ST City: SE BOTHELL State: WA Zip: 98012 Phone: (425) 248-8726 Fax: Contr Reg No.: ORCAEEC944N1 Exp Date: Tukwila Business License No.; 602-644-540 Valuation of Project (contractor's bid price): $�i Scope of Work (please provide detailed information): Adding panel, transformer, timeclock and lighting contactors with occupancy sensors, low voltage track, LED lights and equipment. Will service be altered? ❑ Yes m No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change m Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H:Wpplications\Fort Applications On Line\2014 ApplicationsTlectrical Permit Application Revised 1-1-14.do" Revised: January 2014 bh Adding more than 50 amps? Z Remodel ❑ Telecommunication ❑ Yes m No ❑ Tenant Improvement ❑ Temporary Service Page I of 2 4 I i RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator)...................................$80.90 ❑ Manufactured/mobile home service...........................$86.25 (excluding garage or outbuilding) ❑ Carnivals....................................................................$80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print N Mailing S Ii'l O�A /X. L H:ApplicationsWorms-Applications On Line\2014 ApplicationsUmtrical Permit Application Revised 1-1-14.6oa Revised: January 2014 bh Date: Day Telephone: Z 6 City State Zip Page 2 of 2 DESCRIPTIONS• PermitTRAK QUANTITY PAID $196.50 D15-0204 Address: 856 SOUTHCENTER MALL Apn: 9202470010 $66.50 DEVELOPMENT $66.50 ADDITIONAL PLAN REVIEW R000.345.830.00.00 1.00 $66.50 EL15-0731 Address: 856 SOUTHCENTER MALL Apn: 9202470010 $65.00 ELECTRICAL $65.00 ADDITIONAL PLAN REVIEW R000.345.830.00.00 1.00 $65.00 PG15-0096 Address: 856 SOUTHCENTER MALL Apn: 9202470010 $65.00 PLUMBING $65.00 ADDITIONAL PLAN REVIEW TOTAL'. R000.345.830.00.00 1.00 $65.00 '. 1 Date Paid: Monday, October 05, 2015 Paid By: ROBERT HAISLETT Pay Method: CREDIT CARD 005973 Printed: Monday, October 05, 2015 3:55 PM 1 of 1 rp SY57EM5 DESCRIPTIONS• QUANTITY PAID PermitTRAK $2,920.57 D15-0204 Address: 856 SOUTHCENTER MALL Apn: 9202470010 $2,171.81 DEVELOPMENT $2,068.60 PERMIT FEE R000.322.100.00.00 0.00 $2,064.10 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $103.21 TECHNOLOGY FEE R000.322.900.04.00 0.00 $103.21 EL15-0731 Address: 856 SOUTHCENTER MALL Apn: 9202470010 $434.07 ELECTRICAL $413.40 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $413.40 TECHNOLOGY FEE $20.67 TECHNOLOGY FEE R000.322.900.04.00 0.00 $20.67 M15-0106 Address: 856 SOUTHCENTER MALL Apn: 9202470010 $314.69 MECHANICAL $299.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $267.20 TECHNOLOGY FEE $14.99 TECHNOLOGY FEE R000.322.900.04.00 0.00 $14.99 TOTAL1$2,920.57 Date Paid: Monday, September 21, 2015 Paid By: TAD EDWARDS Pay Method: CREDIT CARD 011260 Printed: Monday, September 21, 2015 8:07 AM 1 of 1 r1 � SYSTEMS Date Paid: Monday, August 24, 2015 Paid By: ARCVISION INC Pay Method: CHECK 33362 Printed: Monday, August 24, 2015 2:59 PM 1 of 1 RWSYS7EM5 INSPECTION RECORD7 ��� Retain a copy with permit ' INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: U Date Called: Special Instructions: Date Wanted: a. ( 0 3 p.m. Requester:'` Phone No: AJApproved per applicable codes. Corrections required prior to approval. `—' paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. 73/ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: A- Type of Inspection: A -[-- Address: ,^ W pate Called: Special Instructions: Date Wanted: 1 Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: //n �'^e�-y�[� t� (,a a � .. L� � 6-7f(� 1— /� ��T W _ ©til© � � �aIZ -- V Ltd c Af C'o J I c LJ paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. INSPECTION RECORD M0�07 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: , AAA - Type of Inspection: ' Address: y Date Called: Special Instructions: Date Wanted: / / I 1 a. 0� Requester: Phone No�& u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 1 / �: Retain a copy with permit INSPEqHON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: ov f�✓ Address: 1 rVV Date Called: Special Instructions: Date Wanted: n� a.m G� p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 1 -3 Retain a copy with permit5�-d731 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: / Address: Date Called: Special Instructions: Date Wanted: /D D� a p.m Requester: Phone No: �0 70 75 Z n Approved per applicable codes. LJ Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD"PERMITNO. Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: � � , Date Called: Special Instructions: Date Wanted: /0 0/ a. 5 p.m. Requester: Phone No: -36o ZY 2 % 9 F Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: A� r D� JSE. L (�S I -50urit. CAIr t.J Inspector: / Date: El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD �v��I Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: lkf� �§— Type of I��ction: - 1 Address: Y5 Date Called: Special Instructions: Date Wanted: a. . p.m Requester: Phone No: 76c) V 75-ZE V3Approved per applicable codes. LJ Corrections required prior to approval. ME IInspector: 4J111 / IDate: '9 / /z-?/ % I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. FREDERICKA. GOGLIA ARCHITECT, NCARB, ISP PROJECT REVISION NO. t Teavana-Southcenter 856 Southcenter Mall Space #1155 Tukwila, WA 98188 Below is a Summary of Changes to the plans per Owner Comments. The changes below are addressed in Revision 3 on the plans. DRAWING REVISIONS: A000 — Revised Index of Sheets to show sheet S201— Structural Details. D100 — Sheet note 25 added to indicate existing metro shelving to be located in space. Sheet note 26 added to indicate to salvage sales area flooring for BOH patching. A100 — Revised Penetration Plan at center table. Revised Stub -up details 2 & 3. Revised sheet note 5. A101— Removed partial wall at center of sales area in plan. Revised wall type 4 to be Not Used and revised wall type 6 to indicate full height plywood on sales floor side in Wall Type Legend. Revised sheet note 5 to indicate correct bottom rail size and note 6 to indicate electrical equipment versus naming specific equipment. Sheet note 11 added to indicate existing in floor grease trap. Sheet note 12 added to indicate existing floor sink. Sheet note 13 added to indicate break metal soffit at storefront. A102 — Revised lighting layout at back of sales area and added track lighting in plan. Removed a total of 4 can lights from front sales area and storefront in plan. Revised soffit finishes at storefront. Revised Ceiling Treatment Schedule — "U". A103 — Revised back wall of sales area in plan per new wall fixtures. Sheet note 1 revised to indicate relocated metro shelving. Revised Furniture Schedule — "F", Data Device Schedule — "A", and Specialty Equipment Schedule — "E". A104— Revised back wall of sales area in plan per new wall casework. Added casework tags to 2 fixtures in plan. Revised Casework Schedule — "C". A105 — Revised detail 3 to be Not Used. Revised cove base and flooring callouts in details 2, 5, 6, 7, and 8. Revised sales area the grid start point in plan. Sheet note 7 added to indicate existing floor sink. Sheet note 8 added to indicate existing in floor grease trap. Sheet note 9 added to indicate BOH floor patching to be done with salvaged sales area flooring. Revised Floor Treatment Schedule — "T" and Wall Base Schedule — "B". RECEIVED A106 — Removed partial height wall at center table in plan. Revised floor finish callout in deVIT2Y OF TUKWIILA Revised wall treatment 3 to be Not Used in Wall Treatment Legend. Revised Wall Treatment (Ar�� Schedule — "Q". PIL15- P 2 8 2015 0-73 1 PERMIT CENTER 1950 Craig Road Suite 300 • St. Louis, MO 63146-4106 • Phone (314) 415-2400 • Fax (314) 415-2300 v4 A200 — Signage Schedule updated. Storefront elevation 1 updated to show extended sign eyebrow, monitor location updated, embossed metal panel on right column of storefront, 6" max dimension added, %Z" tempered glass note added to doors for clarification. Storefront elevation 2 updated to show graphic on right side, glazing and storefront finish tags updated, tile dimension added, embossed metal panel on left side added, %Z" tempered glass note added to doors for clarification. Sheet notes updated. Monitor Detail added to show gyp board framing detail/ leave out at storefront monitor. Door Pocket details revised for clarification. Metal panel/ finish details updated and dimensioned for clarification. A201— Sections updated to show revised eyebrow detailing and framing to allow light recess and 6" max dimension added. Storefront display window section updated to show updated design and heights, embossed metal panel details. Eyebrow construction detail revised per updated design. Sheet notes updated. Staple detail updated per revised design. A202 — Revised neon sign, wet bar casework, and mounting location information on elevation 1. Revised digital monitors and added floating shelve casework on elevation 2. Revised mounting location information on elevation 3. A203 — Revised manager's station layout and added second Fetco on elevation 3. A500 — Revised detail 1 to match revised manager's station layout on sheet A203. M100—Revised the loads to include a higher server load and a lower load for the screen wall which caused the System Load Summary to be changed. Added 75 cfm to the existing VAV. Added a notation that the slats in the staple fixture are W wide at 10'-0" AFF. P100 — Revised Sanitary Plan to show adjusted location of the floor sink under the center table in sales area and revised sheet note 21 to indicate the water heaters under the center table should be installed in the same cabinet that the floor sink is located under. E100— Revised Lighting Plan to sh-6rAd'ditional'track at back portion of sales, removed down lights in front of show window, extended the length of the led at the storefront, and j-boxes were moved. Revised Power Plan to show trenching has been split up to two locations to island, monitor arrangement changed and added two quadplex's for charging portable POS. More dimmers added to switch bank, manager's station shifted upward changing all dimensions. E200 — Light fixture schedule was updated per lighting changes which affected panel schedules and timeclock and lighting contactor control diagram.�.- ''�"'�'1?�e3'fxd`�>`"o-..,. S100 — Re-laid out bracing at staple feature. S200 — Revised details 08 and 09 to match existing beam spacing. S201— Added sheet to drawing set. Moved 100 and 200 series details to this sheet. Added/modified details 102-105 for the staple feature bracing details. Modified detail 204 to show built up beam attachment in lieu of Unistrut. END OF REVISIONS 1950 Craig Road, Suite 300 9 St. Louis, MO 63146 • Phone (314) 415-2400 9 Fax (314) 415-2399 FREDERICA. GOGLIA ARCHITECT, NCARB, ISP PROJECT REVISION NO. 2 Teavana-Southcenter 856 Southcenter Mall Space #1155 Tukwila, WA 98188 Below is a Summary of Changes to the plans, including Landlord Comments, Health Department, and Owner Comments. The changes below are addressed in Revision 2 on the plans. DRAWING REVISIONS: a I O..L "Store # and Project # added to every sheet. REVISIO I A000— Health department notes added. Revised Index of Sheets to show MEP sheets. D100 — Note 24 added to indicate existing grease trap to remain. A100 — Dimensions to locate electrical and plumbing stub -ups have been revised. Details 2 and 3 revised to align with engineering drawings. Stub -up for POS removed. Flooring in detail 4 revised to show tile. Plan Note E revised to show Not Used. A101— Updated dimensions and location of knee wall in center of store. Updated dimensions of staple fixture at storefront and glazing, updated dimensions of corner build -out. Updated sheet notes to specify finish. Revised Wall blocking legend for Retail Blocking's height. A102 — Revised Reflected Ceiling Plan per new lighting layout. Revised Sheet Note #5 and added Reflected Ceiling Plan Note "M". Revised Ceiling Treatment Schedule — "U" to show SW Repose Gray. A103 — Central table updated per Store Design. Additional Fetco added to plan in Stockroom. Lockers and coat hook added to stockroom per Health Department comments. Ice Machine spec revised. Plan notes E and F revised. Sheet note 2 shown as Not Used. Sheet note 12 removed. A104—Casework schedule revised A105 — Floor finish at corner column revised to "C" — N/A. Floor penetration locations updated. Retail area tile pattern added to plan. Location of finish transition from Retail to Stockroom revised. Detail 2 revised to correct finishes and dimensions. Details 3 & 4 revised to show cove height. Detail 5 revised to show stockroom flooring and the correct size of retail flooring. Details 6, 7 & 8 added to the sheet. Floor and Wall Base schedules revised to include more information. Sheet note 6 added to sheet. A106 — Wall finish revised at corner column. Finishes added to storefront/staple feature. Sheet note 8 added to wet bar location. Flooring and cove base size revised in detail 2. Detail 3 removed sheet. Sheet note 8 revised for location at Wet Bar. Wall treatments 1, 2, 5, 6 and 10 revised. IN D schedule revised to include more detail. — Of RMTKWILA LL 15 0731 SEP 28 2015 1950 Craig Road Suite 300 • St. Louis, MO 63146-4106 • Phone (314) 415-2400. Fax141�1]�5�2 0ENTEI % , 1 A200 — Notes added for tile base to align with base of door/glazing system. Digital tile removed from design. Large format tile pattern revised. Note to align seams in glazing with vertical members of Staple fixture. Protective window box added to digital tile at corner. Closure doors added to pocket doors at storefront. Detail 3 revised to show pocket door cover. Detail 4 revised to show pocket door cover, window box at corner and dimensions adjusted on build -out. Signage schedule updated. Sheet notes 1, 2, 3, 4, 6 and 9 revised. A201— Detail 9 added for Staple Fixture Detail. Finishes and eyebrow details updated on sections 1, 2, 3, 4 & 5. Digital tile removed from sections above the eyebrow. Details 9 & 10 added to sheet. Sheet note 7 revised. A202 — General notes added to coordinate locations with Teavana PM. Backsplash removed from wet bar in elevation 1. Fixture X9401 revised in elevation 1. Rear wall digital display revised in elevation 2. Note added to elevation 3 to show blank space as "open to mall". M100 —Added sprinkler head to HVAC Symbol Legend and revised the last Mechanical General Note. P100 — Revised Plumbing Fixture Schedule, New Plumbing Fixture Calculations, Water Plan, Sanitary Plan, and Plumbing Keyed Notes #1, 9, 12, 21-25. P200 — Revised Waste Riser with removal of floor sink and Water Riser with addition of new hot water machine. E100-Revised Lighting Plan per new lighting layout. Revised Power Plan, Switch Bank, Symbol Legend, Manager's Station Detail, and Manager's Station Keyed Note #6. Revised Electrical Keyed Notes #6-15 & 24-31. E200 — Revised Light Fixture Schedule, Lamp Schedule, Panel LP Demand, Service Demand, Panel LP Breaker Schedule, & Timeclock and Lighting Contractor Control Diagram. S100 —Soffit support on the ng t side ofth'e space .�as been . aLd.justed'to remove t e mi a a le co The beam sizes have been modified to accommodate the longer spans. S200 — The beams in detail 10 have been spread out to match the new soffit size. Detail 11 has been added to accommodate the new beam configuration END OF REVISIONS 1950 Craig Road, Suite 300 . St. Louis, MO 63146 9 Phone (314) 415-2400 • Fax (314) 415-2399 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0731 DATE: 09/28/15 PROJECT NAME: TEAVANA SITE ADDRESS: 856 SOUTHCENTER MALL Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: .f Ate' AV Building Division is Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 09/29/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/27/15 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 eERMOT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0731 DATE: 08/24/15 PROJECT NAME: TEAVANA SITE ADDRESS: 856 SOUTHCENTER MALL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Gj1 �0 4 Bull ing Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 08/25/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/22/15 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PROJECT NAME: 7,f'A Qa .11" 4fA SITE ADDRESS: &aj !e" .- 1')1-d1 PERMIT NO: I� 1,,., I S = V 3 ORIGINAL ISSUE DATE: -)I — ( -,;--- REVISION NO. f DATE DECEIVED I STAFF INITIALS ISSUED DATE STAFF INITIA Summary of Revision: t ` S Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila Department of Conmusnity Development 6300 Southcenter Boulevard- Suite 4100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://NNwANr.'TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, eta Date: 09/28/2015 Plan Checic/Permit Number: EL15-0731 Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Teavana South Center Project Address: 856 South Center Mall Contact Person: Andy Paroline Summary of Revision: see attached revision narrative Sheet Number(s): see attached revision narrative "Cloud" or highlight all areas of revision including date of C Received at the City of Tukwila Permit Center by: _ Entered in Penuits Plus on 4 r� S Phone Number: (206) 719-0339 SEP 2 8 2#19, H:\Applintions\Forms-ApplicatimL On Line\2010 AppheatiomgW-2010 - Revision Snlmittaldoc Revised: May2011 ORCA ELECTRICAL CONTRACTORS Page 1 of 2 Home Inicio en Espanol Contact Safety Washington State Department of Labor & industries ORCA ELECTRICAL CONTRACTORS (Search L&I A -'I. Index Help Xly Secure I &I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 2704 171 ST ST SE BOTHELL, WA Princi als p 425-585-0101 CABUAG, JOHANNA M, PARTNER/MEMBER SNOHOMISH County CABUAG , JACOB K M SR, PARTNER/MEMBER Doing business as ORCA ELECTRICAL CONTRACTORS WA UBI No. Business type 602 644 540 Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. .............................................................. Meets current requirements. License specialties GENERAL License no. ORCAEEC944NU Effective — expiration 08/31 /2006— 09/16/2016 Designated administrator Active. CABUAd,BARNEY Meets current requirements. License type License no. Master Electrician CABUAB'966MB Bond ..........._.... Wesco Insurance Co $4,000.00 Bond account no. 46WBO34916 Received by L&I Effective date 09/16/2013 10/09/2013 Expiration date Until Canceled Bond history Savings No savings accounts during the previous 6 year period. License Violations Infraction no. EDUNY00316 Satisfied .................... Issue date RCW/WAC 01/30/2014 19.28.101 RCW Violation city Violation amount BOTHELL $250.00 https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602644540&LIC=ORCAEEC944NU&SAW= 9/21/2015 fE ':......................... TYPE "R2A" TYPICAL TYPE "TIC" N LP-9r TYPE "L1" TYPICAL LP-9 TYPE '7C" LP-9g TYPE "L1 " TYPICAL 2}k a TYPE "R4A" TYPICAL / 1 LP-7 LP-1 a .1-.-n 1 ALP TYPE "CA" TYPICAL 0 aL�(�I11MG PLAN williLB yr • ,-W 1 PP-8,10 PP-2 LP-9r LP-9 ICAL LP-14,16 LP-12 PP-1 PP-3 s MAKING PROVISION FOR ANY ADDITIONAL CAPACITY IS TENANT'S G.C. "RESPONSIBILITY. A MANAGER'S STATION KEYED NOTES �1 JUNCTION BOX FOR DT TIMER OJUNCTION BOX FOR HIGH SPEED INTERNET AT 101" A.F.F. O3 JUNCTION BOX FOR DEMARC EXTENSION AT 101" A.F.F. LP-12 O4 EMS DATA CONCENTRATOR AT 101" A.F.F. O5 JUNCTION BOX FOR SECURITY PANEL AT 101" A.F.F. AND 15" CLEAR LP-12 FROM ADJACENT BOX ODUPLEX RECEPTACLE WITH TWO DEDICATED OUTLET CIRCUITS FOR MOSAIC POWER SUPPLY MODULE 1,2. E.C. TO BREAK TAB BETWEEN PP-5 UPPER/LOWER OUTLET TO ALLOW FOR SEPARATE CIRCUITS. FIELD VERIFY EXACT LOCATION WITH TEAVANA REP. O7 DUPLEX RECEPTACLE FOR SECURITY AT 51" A.F.F. ODEDICATED QUAD RECEPTACLE FOR DATA RACK EQUIPMENT AT 38" A.F.F. PP-4 O DATA OUTLET FOR PRINTER. FIELD VERIFY EXACT LOCATION WITH TEAVANA REP. 10 DUPLEX RECEPTACLE FOR PRINTER. FIELD VERIFY EXACT LOCATION PP-9 WITH TEAVANA REP. 11 DUPLEX RECEPTACLE FOR SECURITY PANEL AT 101" A.F.F. 12 QUADPLEX RECEPTACLE FOR SECURITY CAMERA POWER SUPPLIES AT 101" A.F.F. CDCONVENIENCE DUPLEX RECEPTACLE AT 97" A.F.F. 14 DUPLEX RECEPTACLE FOR MUSIC SYSTEM AT 48" A.F.F. PP-5 15 DEDICATED DUPLEX RECEPTACLES FOR WORKSTATION AT 42" A.F.F. LP-22 16 PHONE OUTLET AT 42" A.F.F. CDQUADPLEX CONVENIENCE RECEPTACLE AT 12" A.F.F. 18 DUPLEX RECEPTACLE WITH DEDICATED GROUND AND ONE PHONE OUTLET FLUSH MOUNTED VERTICAL AT 12" A.F.F. IN WALL FOR DIGITAL SAFE. FIELD VERIFY EXACT LOCATION. rREVISIONSi ELECTRICAL KEYED TES , sion11q Ue u im L.w,: plan L NOTE.: Revisions will require a new plan submittal cid 'ude additional pian review floes. :pG6p8lnrs0UN39 Sr suoltipuoo pue Adop ple! pi►oiddti"fo 0 E.C. SHALL INSTALL DISCONNECT SWITCH FOR SIGNAGE CIRCUITS) AS 17 EXISTING RECEPTACLE AND SWITCHED TO REMAIN. RECIRCUIT AS INDICATED. ld;aoea •eoueUlp10 ao Gpoo peldops Aua jo uoIjvIoIA etit Revision schedule µ , REQUIRED BY N.E.C. 600. REFER TO PLANS FOR NUMBER OF CIRCUITS ezuorltne;ou seop stuewnaop uol n�tsuoo;u Isnaddb REQUIRED. E.C. TO MAKE ALL CONNECTIONS TO SIGN. 18 TABLE TOP G.F.C.I. RECEPTACLE POPUP. E.C. TO FIELD VERIFY EXACT Rev Date �By Description M a,� n •suai:�s;wo pua s1oJ,a of efgns sr 113nadde n�eine� us31 �® LOCATION WITH TEAVANA REP. AND LOCATION WITH FIXTURE INSTALLER. 2 09,15�1 CW g�OWNER .'X.-HEALTH C� ENT 2 ........,15 . R PLAIN'O E.C. SHALL FIELD VERIFY EXACT REQUIREMENTS FOR SMOKE/FIRE ALARM 3 09 23 1 CW -O tNER, ICGMMENTS�- SYSTEM. REUSE ANY EXISTING DETECTION SYSTEM. REPLACE ANY DEFECTIVE 19 FIELD VERIFY EXACT LOCATION OF LANDLORD TELEPHONE SERVICE STUB -IN .. 3 w u ION 41WJ9 SCAM �� ®'r.� DEVICES. IF THERE IS NOT AN EXISTING SYSTEM, E.C. SHALL SUPPLY AND AND EXTEND AS REQUIRED FOR CONNECTION TO TENANT TELEPHONE •-•�.ww• •�•�••��• •••••�•••• I••• p' ••••••-�••-••• •�• ••• �•-•-• INSTALL ALL NECESSARY EQUIPMENT (SMOKE DETECTORS, AUDIO/VISUAL EQUIPMENT. ENSURE EXISTING SERVICE WIRE IS CAT5 OR BETTER. IF NOT, I .�`"' P'wchar.:c;l _...........................__.......... _...........>._......................_........................................_............. E.C. SHALL PULL NEW CABLE (AND CONDUIT IF REQUIRED) FROM LANDLORD _ Li C'2c2ricwt AdO:) , ALARMS, FIRE ALARM PANEL, CONDUIT, WIRE, ETC.) FOR A NEW SYSTEM AS EQUIPMENT TO TENANT SPACE SERVICE CABLE SHALL TERMINATE WITH RJ11 2401 Utah Avenue South Seattle, Washington 98134 (206) 318-1575 THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORP. WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FORA PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THEOTHER (EXCEPTASSTATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. a,,,,, ,, FILE e Permit �.�o. �� Ian review approw'' ; .' jr,j':,; ; b errors and om ysions. PProval nF construction du - mnts doc:: riot a horize e violation of any adopter: C; a or ordnance. I leceipt Approved Field Copy and conditions is ackn edged: Y: __.. . Dater t 0 -I S =� City of T;kkwila BUILDING DIVISION THIS DRAWING PREPARED UNDER MY SUPERVISION, AND I DISCLAIM ANY RESPONSIBILITY FOR THE EXISTING BUILDING, CONSTRUCTION ELEMENTS, SITE CONDITIONS, OR ANY DOCUMENT WHICH DOES NOT BEAR MY SEAL. 97 REGISTERE ARC ITEC FREDERICK J. GOGLIA STATE OF WASHINGTON NOTE: LIGHT NSILFIXTURES WASHING (AREAS DARE TOABETIOF, OPEN SHATTER -OD PROOF STORAGE PR00 S B ND CONSTRUCTION OR PROTECTED AGAINST BREAKAGE THROUGH THE USE OF PLASTIC LIGHT SHIELDS OR OTHER APPROVED DEVICES. a b C d LP-1 LP-1 LP-5 LP-5 GENERAL GENERAL SALES SALES DOWN TRACK RACK TRACK DIMMER DIMMER DIMMER DIMMER a o a o I_P-5 LP-9 LP-9 LP-13 SALES UNDER WET FRONT TRACK SELF LED DISPENCER COLOR LED DIMMER DIMMER DIMMER DIMMER J GENERAL LTG 0 SPRING WOUND MANUAL BYPASS TIMER WITH 0-2 HOUR RANGE WITHOUT HOLD DEDICATED FEATURE FOR GENERAL LIGHTING CONTACTOR DUPLEX RI PARAGON #ETPD/120 2450 FOR POS CONTRACTOR TO VERIFY EXACT CONFIGURATION SEE PLAN REQUIRED WITH SPACE AVAILABLE. PROVIDE FOR LOCK LABELS AS DIRECTED BY OWNER. SWITCHES SHALL NOT BE MOUNTED HIGHER THAN 48" ® SURFACE MOUNTED RECEPTACLE UNIPLEX RECEPTACLE (SINGLE) DUPLEX RECEPTACLE DUPLEX ISOLATED GROUND QUADPLEX RECEPTACLE QUADPLEX ISOLATED GROUND ® SPECIAL VOLTAGE OR AMPERAGE ® TELEPHONE OUTLET JQ JUNCTION BOX Q DATA OUTLET G1 DOORBELL PUSHBUTTON a DOORBELL ® DOORBELL LOW -VOLT TRANS © LOW -VOLTAGE TRANSFORMER ❑ I DISCONNECT SWITCH Q-I TRAFFIC COUNTER TELEPHONE BOARD ELECTRICAL PANEL KVA TRANSFORMER T/C 24HR 7 DAY -TIME CLOCK $ WALL SWITCH J-BOX os CEILING OCCUPANCY SENSOR FOR DATA sP 1 SPEAKER J-BOX FOR PHONE 3 #12, 3/4"C (2 CKT WIRES, 1 NEUTRAL, 1 GROUND) CIRCUIT HOME RUN CONDUIT THRU/BELOW FLOOR IL 0 SW1r1r%C%.H9Z K TYP OS STATION a— CONDUIT STUBBED UP/DOWN SCALB Nam BOA Z 3/4! - r-W N.L. NIGHT LIGHT VIA T/C TIMECLOCK CONTROLED CIRCUIT Architect: Frederick Goglia ARC VISION, INC. 1960 CRAIG RD. SUITE 300 • ST. LOUIS, MO 63146 • I mbir. u MAY BE U �........�....i.,_,.......�.,,�...............�.......,. ,..,............. �....,,.,,._,.....•....3.,,.,,...,,..,,r..�..........,. REQ (RED BY LANDLORD AND/OR LOCAL FIRE MARSHALL. INSTALL JACK ON BACKBOARD. PROVIDE 3 4" PLYWOOD BACKBOARD FOR MOUNTING I P"s� SMOKE DETECTORS IN SUPPLY OR RETURN DUCTWORK AS REQUIRED BY OF NEW ELECTRICAL AND TELEPHONE EQUIPMENT. SIZE AND SECURE AS -,.,..,. _,,,,,,,.�.....�._{_ LOCAL AUTHORITY. FIELD VERIFY AND COORDINATE. E.C. TO USE SIMPLEX REQUIRED. PROVIDE DEDICATED GROUND DUPLEX RECEPTAC EOI)T GRINNEL FOR THE FIRE ALARM SYSTEM. , CWE_ TELEPHONE EQUIPMENT. COMPLIANCE: �f'M MY _ rUG D`:'.+ E10IN O3 6-30R RECEPTACLE MOUNTED HORIZONTALLY AT 48" A.F.F. FOR FETCO HOT 20 PANEL "LP". REFER TO PANEL SCHEDULE. 1uVPA70 - NEC WATER MACHINE. .I RECEIVED ® ROUTE 1" CONDUIT IN WALL. CONDUIT TO EXTEND 6" ABOVE CLG. AND 21 PANEL "PP". REFER TO PANEL SCHEDULE. OCT 0 5 2015 CITY OF TUKWILA STUBUP IN WET BAR. E.C. SHALL RUN IN BASE OF WET BAR TELE./DATA 22 DISCONNECT.. REFER TO ONE -LINE DIAGRAM. SEP 2 8 2015 THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE ENTIRE LINES (5 CAT 5) FROM T.B.B. TO EQUIPMENT WITH 6' COILED CABLE (4) -.._ �- SPECIFlCATION AND REVIEW DRAWINGS FOR ALL OTHER TRADES, FOR OUTLETS IN COUNTER WITH THE CABLE NEEDS TO HAVE 2 ENDS. E.C. TO 23 TRANSFORMER. REFER TO ONE -LINE DIAGRAM. 2BUI�LDING Ofi-TUkwtla, A COMPLm ONDERSTANDING OF THIS PROJECTS ELECTRICAL REQUIREMENTS. TERMINATE AT WET BAR. PHONE COMPANY TO TERMINATE AT PHONEBOARD. DIVIBIO PERMIT CENTER PROVIDE `CONDUIT AND_ WIRE FOR POWER AND DATA/PE 50 DUPLEX W/DEDICATED GROUND AND DATA CONNECTION FLUSH MOUNTED IN CONDUITS AS SHOWN ON PLAN`"DOWN-WALL OR COLUMN AND BY SAW W CASH WRAP AT 24" A.F.F. FOR LABEL PRINTER. FIELD VERIFY EXACT CUTTING OR CORE DRILLING FLOOR AS"REQUIRED BY LANDLORD. PATCH ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR TERMINATING ALONG WITH LOCATION. FLOOR AS REQUIRED. COORDINATE EXACT CONFIGURATION WITH TENANT REP. PULLING THE CAT 5 CABLE. AND LOCATION WITH FIXTURE INSTALLER. z 00 © J-BOX FOR CONNECTION OF ALION LED DRIVER FOR POWERING COLOR IF A PHONE SERVICE IS REQUIRED TO BE PULLED FROM THE L.L. TELEPHONE W T_ ROOM (USUALLY NEW CONSTRUCTION) THEN THE E.C. WILL NEED TO CHANGING LED TAPE LIGHTING AT STORE FRONT. E.C. TO FIELD VERIFY EXACT 25 PROVIDE HOT, UNSWITCHED CONDUCTOR TO EMERGENCY/EXIT LIGHT TO o0 TERMINATE THE STORE SIDE OF THE CABLE (4 RJ1 1 CONNECTIONS) LOCATION WITH TENANTS PROJECT MANAGER. RENDER FIXTURE OPERATIONAL 24HRS A DAY. 0 LO THE E.C. WILL NEED TO TERMINATE THE FAX MACHINE LINE. " � Z D U � Q O DUPLEX RECEPTACLE FLUSH MOUNTED VERTICAL IN WALL AT 18 A.F.F. FOR 26 DUPLEX RECEPTACLE FLUSH MOUNTED VERTICAL IN CABINET AT 26" A.F.F.. E � -C -o THE E.C. WILL NEED TO TERMINATE THE CABLE UNDER THE CASHVIRAP BY GENERAL USE. co Z Q O � � SUPPLYING AND INSTALLING A SURFACE MOUNT UTILITY BOX AND A 27 GENERAL LIGHT FIXTURE TO BE CONTROLLED BY LOCAL OCCUPANCY SENSOR ,& , Z) 4 PORT COVER PLATE. O8 DUPLEX RECEPTACLE FLUSH MOUNTED IN CEILING PER N.E.C. 210-62. 3 AFTER UNOCCUPIED HOURS. � U BONE/IVORY IN COLOR. O o 'o tri Y 28 J-BOX CONCEALED UNDER COUNTER FOR CONNECTION OF ALION LED 0-10 2 t0 � O9 FIELD VERIFY EXACT LOCATION OF J-BOX FOR ICE MAKER. DIMMABLE LED DRIVER (D100-Z-24) FOR POWERING LED TAPE LIGHTING. I4EI- AJ. EL.I I M1CA1. r4U I r.S 10 E.C. TO RUN SPEAKER WIRE FROM SPEAKER LOCATIONS AND ROUTE DOWN E.C. TO FIELD VERIFY EXACT LOCATION WITH TENANT REP. AND LOCATION INSIDE WALL TO DATA OUTLET LOCATION FOR CONNECTION OF AMPLIFIER. WITH FIXTURE INSTALLER. MAKE FINAL CONNECTIONS. 29 J-BOX FOR CONNECTION OF ALUMA-PAK ELECTRONIC NEON POWER SUPPLY 1. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND SHALL IMMEDIATELY NOTIFY THE OWNER'S PROJECT MANAGER OF ANY SS9350X) FOR POWERING NEON SIGN LIGHTING. E.C. TO FIELD VERIFY 1 1 E.C. TO FIELD VERIFY AND SUPPLY CONNECTION OF (1) 55" MONITOR FROM DISCREPANCIES. EXACT LOCATION WITH TENANT REP. J-BOX BACK TO MOSAIC POWER SUPPLY MODULE #2. E.C. TO INSTALL ONE 2. ALL CONDUITS ARE TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. DUPLEX RECEPTACLE BEHIND EACH MONITOR. 30 J-BOX FOR CONNECTION OF COOLEDGE LED 0-10V DIMMABLE LED DRIVER CONDUITS IN EXPOSED CEILING AREAS SHALL EXIT WALLS AS CLOSE TO (EDRV-030W-UNV-058-010-0606-4-SM) FOR POWERING LED SHEET ROOF/FLOOR STRUCTURAL DECK AS POSSIBLE. 12 E.C. TO FIELD VERIFY AND SUPPLY CONNECTION OF (1) 22" MONITORS, (1) LIGHTING. E.C. TO FIELD VERIFY EXACT LOCATION WITH TENANT REP. AND 46" MONITOR AND (1) 55" MONITOR FROM J-BOX BACK TO MOSAIC POWER LOCATION WITH FIXTURE INSTALLER. 3. ANY EXISTING MATERIALS OR EQUIPMENT NOT TO BE REUSED MUST BE SUPPLY MODULE #1. E.C. TO INSTALL ONE DUPLEX RECEPTACLE BEHIND COMPLETELY REMOVED AND DISPOSED OF PROPERLY THROUGH THE EACH MONITOR. 31 DUPLEX RECEPTACLE AT 12" A.F.F. FOR UNDER COUNTER INSTANTANEOUS LANDLORD'S DESIGNATED AND APPROVED HAULER. NO EQUIPMENT OR WATER HEATER. FIELD VERIFY EXACT LOCATION. COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION OF THE 13 E.C. TO FIELD VERIFY AND SUPPLY CONNECTION OF (1) 22" MONITORS, AND LANDLORD. (1) 55" MONITOR FROM J-BOX BACK TO MOSAIC POWER SUPPLY MODULE #2. 0 QUADPLEX RECEPTACLE FOR PORTABLE POS CHARGING STATION. FIELD VERI Sheet Title: 4. ANY PENETRATIONS THROUGH FIRE RATED WALLS NEED TO BE APPROPRIATELY E.C. TO INSTALL ONE DUPLEX RECEPTACLE BEHIND EACH MONITOR. EXACT LOCATION WITH TEAVANA REP. !LIGHTING AND FIRE STOPPED TO RETAIN THE WALLS RATING. 14 E.C. TO INSTALL NEMA 6-50R RECEPTACLE AT 18" A.F.F. AND A NEMA 6-50P FOR DISHWASHER. FIELD VERIFY EXACT LOCATION. REVISIUNIN0. POWER PLAN 5. CONTRACTOR SHALL ENSURE LOADS BETWEEN PHASES ON PANEL BOARDS t .1 ARE BALANCED WITHIN 10%. 15 DUPLEX RECEPTACLE FLUSH MOUNTED VERTICAL IN WALL AT 84" A.F.F. FOR 3 Scale: As noted REFRIGERATOR/FREEZER. 6. ALL LOW VOLTAGE WIRING IN CEILING PLENUM (INCLUDING TELEPHONE. DATA, Sheet Number: ALARM AND TEMP. CONTROL, SPEAKER WIRING, AND ETC.) SHALL BE 16 NON -FUSED DISCONNECT SWITCH FOR CONNECTION OF TANK TYPE WATER15 -am, 013 UL LISTED TEFLON PLENUM CABLE. H�• EL E-� 00 REFER TO SPEC'S FOR TIMECLOCK. COORDINATE TIME SETTINGS WITH OWNER AND LANDLORD. OVERRIDE TIMER. SEE SWITCH BANK DETAIL - CIRCUIT BRKR DESCRIPTION SIGN -STOREFRONT LTG -EXTERIOR LED/ DOWN REC-STOREFRONT SPARE CIRCUIT BRKR DESCRIPTION LT G-SALES TRACK EM EXIT LTG-S SPARE SPARE SPARE CIRCUIT BRKR DESCRIPTION LTG -TRACK LTG -SALES LED LTG -SALES NEON SIGNS SPARE SPARE SPARE LP-4 N.C. - - .I - I IV.V. I -� N.C. I -7 N.C. N.C. 1. H STOREFRONT CONTACTOR GENERAL LTG CONTACTOR (ELECTRICALLY HELD) 1 DISPLAY LTG CONTACTOR K=Mc; TIMECLOCK AND LlGlullnING CO TACTOR CONTROL DIAGam"AM 810MB NOW * - UNSWITCHED LEG TO FIXTURES REQUIRING 24HR. OPERATION. N.C. = NORMALLY CLOSED N.O. = NORMALLY OPEN TIMECLOCK AND CONTACTOR FOR AUTOMATIC SHUT OFF OF ALL SPACE LIGHTING AS REQUIRED BY ENERGY CODE PANELBOARD DESIGNATION __ -1201205 VOLTS 3 PHAASE TOP FED __ BOTTOM FED X 4 WIRE, FLUSH NEW INSTALL ___ EXIST SOLID NEUTRAL _1 AMPERE BUS MTD -_ SURFACE MTD LOCATION ___ RELOCATED EXIST ___ _-AMPERE MAIN EFEA ER ____ CKT # DESCRIPTION WATTS LOAD TYPE WIRE SIZE BRKR SIZE A B C 37122 2088#I-,z 27561 900 J C BRKR SIZE WIRE SIZE LOAD TYPE WATTS DESCRIPTION CKT # 1 REC-DATA RACK 360 R 12 20 1 1 15 12 R 1728 REC-ICE MAKER 2 3 REC-PRINTER 1200 R 12120 1 1 20 12 R 300 REC-IPODS & AMP 4 5 REC-GEN. MANGER DESK 540 R 12 20 11 20 12 R 1020 REC-REFRIG/FREEZER 6 7 REC-POS CHARGE STATION 540 R 12 20 1 40 8 M 3172 DISHWASHER 8 9 REC-WORKSTATION 360 R 12 20 1 3172 10 11 AHU-1, CU-1 1456 M 112115 21 20 12 M 1300 INSTANT. WATER HEATER 12 13 1456 20 12 M 1300 INSTANT. WATER HEATER 14 15 FETCO WATER MACHINE 1950 M 10 30 2 2 30 10 M 1950 FETCO WATER MACHINE 16 17 1950 1950 18 8556 8932 8216 SUB TOTALS CONNECTED LOAD 2570_4 PHASE BALANCE ___ 8.OX L = LTG OR SIGNAGE R = RECEPTACLE M = MISCELLANEOUS H = H.V.A.C. K = KITCHEN NOTE: ALL BREAKERS SHALL BE BOLT -ON UNLESS OTHERWISE NOTED. ® - INDICATES THIS CIRCUIT TO RECIEVE HANDLE LOCK -ON CLIP � 0 ONE -LINE DIAGRAM FOR WIRE SIZE TO THIS k REFER T EQUIPMENT SERVICE DEMAND LOAD CONNECTED DEMAND PANEL LP DEMAND LOAD CONNECTED DEMAND TRACK (6) TRANS. X 240W PER LOW VOLTAGE TRANSFORMER 1440W 180OW ROOF LINE EXISTING 120V, 10, 30A.S., 7A.F. FOR EXISTING FPVAV EXISTING 5.5 F.L.A. RECEPTACLE AND SWITCHED NEW BY _ - EBY LIGHT 1N.F. FOR NEWG.C.AHU� 1,OCU 14 M.C.A. NEW BY E.C. NEW BY E.C. 2 12, 3/4"C 2 12, 3/4"C 1 12 GND 1 12 GND UNISTRUT CROSS BRACING FOR MOUNTING PANEL TO BE MOUNTED NO TRANSFORMER REFER TO HIGHER THAN 6'7" TO THE ARCHITECTURAL DRAWINGS TOP OF THE HIGHEST FOR ADDITIONAL BREAKER PER N.E.C. 240.24 EXIST. (MIN) INFORMATION. E NEW BY E.C. 1 8 GND NEW 30KVA, 30 PANEL T/ TORK DTS400B TRANSFORMER TIMECLOCK FOR EXIST. (MIN) NEW BY E.C. 480/120/208V LP STOREFRONT 4 13, 1-1 /4"C 1 3 8, 1 1 "C 1 8 GND 1 IO GND REFER TO NEW BY E.C. PANEL RECEPTACLE FOR E.C. TO EXIST 200AS r ---- SCHEDULE TELEPHONE. VERIFY FIELD VERIFY EXACT M 1 NEW 100AF ¢ i i I EXACT LOCATION METER REQUIREMENTS 1 i i i PANEL EXIST. 100A.S. WITH 100A.F. -•- 1-__- 1 i 1 PP SERVICE FROM LANDLORD I II I 30, 4W ELEC. REFER TO 277/48OV, I i II I PANEL DISTRIBUTION EQUIPMENT z SCHEDULE- (0--------LEASE LINE--_I_NEW 60AS, 45A.F. - _ - - - FLOOR LINE EXIST 30KVA, 30 1 #6 - - NEW BY E.C. TRANSFORMER GND TO 4 1-1 /4"C 480/120/208V BLDG STEEL $3, 1 8 GND t1 a� CLECTRICAL Oim E-LI E DIAGRA , SCAM. 1. ALL WIRE SHALL BE COPPER ONLY, THW, THWN, 3. ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMER, THHW, OR NEC APPROVED EQUAL OR BETTER. ALL LIGHTS, DEVICES, CONDUIT, WIRE, ETC.) NOT BEING a- WIRING SHALL BE IN CONDUIT. WIRE AMPACITY BASED USED SHALL BE REMOVED FROM THE SITE. E (-0 ON NEC 110-14c AND TABLE 310-16. DO NOT ABANDON IN PLACE. cu 0) 2. E.C. SHALL FURNISH ALL NEW ELECTRICAL EQUIP. 4. E.C. SHALL FIELD VERIFY ALL EXISTING ELECTRICAL aD E (PANELS, TRANSFORMER, CONDUIT, ETC.) AS EQUIPMENT. ALSO FIELD VERIFY THAT ANY EXISTING REQUIRED, UNLESS NOTED OTHERWISE. ELEC. EQUIPMENT TO BE REUSED IS OF ADEQUATE SIZE AND CONDITION TO MAINTAIN SAFE OPERATION. IF DISCREPANCIES ARISE CONTACT PROJECT REP. CU 0.... PANEL PP DEMAND LOAD CONNECTED DEMAND RECEPTACLESW 3300 3300 W EQUIPMENT 9092W 9092W WATER HEATER 1040OW 1040OW HVAC 2912W 2912W TOTAL 251 704W 25. 704W 25,704W _ (208 X1.73) 71.4 AMPS DESIGN THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE ENTIRE SPECIFICATION AND REVIEW DRAWINGS FOR ALL OTHER TRADES, FOR A COMPLETE (1NDERSTANDING OF THIS PROJECTS ELECTRICAL REQUIREMENTS. CONTRACTOR'S MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. ANY DISCREPANCIES IN EXISTING CONDITIONS AS SHOWN SHOULD BE BROUGHT TO THE ATTENTION OF TEAVANA CONSTRUCTION DEPARTMENT AND CLARIFIED BEFORE SUBMITTING BIDS. CHANGE ORDERS WILL NOT BE ALLOWED FOR ANY WORK REQUIRED DUE TO EXISTING CONDITIONS NOT BEING FIELD VERIFIED BY CONTRACTOR PRIOR TO SUBMITTING BID. 1. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND SHALL IMMEDIATELY NOTIFY THE OWNER'S PROJECT MANAGER OF ANY DISCREPANCIES. 2. ALL CONDUITS ARE TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. CONDUITS IN EXPOSED CEILING AREAS SHALL EXIT WALLS AS CLOSE TO ROOF/FLOOR STRUCTURAL DECK AS POSSIBLE. 3. ANY EXISTING MATERIALS OR EQUIPMENT NOT TO BE REUSED MUST BE COMPLETELY REMOVED AND DISPOSED OF PROPERLY THROUGH THE LANDLORD'S DESIGNATED AND APPROVED HAULER. NO EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION OF THE LANDLORD. 4. ANY PENETRATIONS THROUGH FIRE RATED WALLS NEED TO BE APPROPRIATELY FIRE STOPPED TO RETAIN THE WALL'S RATING. 5. CONTRACTOR SHALL ENSURE LOADS BETWEEN PHASES ON PANEL BOARDS ARE BALANCED WITHIN 10%. 6. ALL LOW VOLTAGE WIRING IN CEILING PLENUM (INCLUDING TELEPHONE. DATA, ALARM AND TEMP. CONTROL WIRING) SHALL BE ULC LISTED FT6 RATED CABLE. WHEN REUSING EXISTING PANELS, E.C. SHALL VERIFY THE CONDITION AND QUANTRY OF ALL EXISTING CIRCUIT BREAKERS. REPLACE DAMAGED BREAKERS WITH NEW. PROVIDE ANY ADDITIONAL OR BREAKERS OF DIFFERENT AMPERAGE OR POLE AS REQUIRED TO MEET THE END RESULT INDICATED IN THE PANEL SCHEDULE. NEW BREAKERS SHALL BE OF THE SAME MFG AND CHARACTERISTICS OF THE EXISTING. THE SUBMISSION OF THE BID PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED TO THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE SITE. PANELBOARD DESIGNATION _wLF NEW INSTALL _M EXIST LOCATION N_ RELOCATED EXIST X 120 2Q8_VOLTS _3 PHASE A WIRE, SOLID NEUTRAL 12J_AMPERE BUS 100_AMPERE MAIN BREAKER TOP FED --- BOTTOM FED X FLUSH MTD --- SURFACE MTD X CKT DESCRIPTION WATTS LOAD TYPE WIRE SIZE BRKR SIZE o a A B C 663 1380 838 669 1716 1080 458 1313 -- -- 3000 3000 -- 660 -- o a BRKR SIZE WIRE SIZE LOAD TYPE WATTS DESCRIPTION 1 LTG -SALES/TRACK/EM/EXIT 433 L 12 20 1 1 20 12 R 230 REC-P.O.S. 2 3 SIGN -STOREFRONT LTG -TRACK 1200 598 L L 12 12 20 20 1 1 1 20 12 R 180 REC-STOREFRONT 4 5 1 20 12 R 240 REC-SCALES 6 7 LTG-STOCK/EM/EX 129 L 12 20 1 1 20 12 R 540 REC-GEN. CASH DRY BAR 8 9 LTG -SALES LED NEON SIGNS 756 L 12 20 1 1 20 12 R 960 REC-GENERAL HVAC 10 11 SPARE -- - - 20 1 1 20 12 M 1080 REC-PH. CLOCK SECURITY 12 13 SPARE -- - - 20 1 1 20 12 R 458 MOSAIC PW. SUPPLY 1 14 15 LTG -EXTERIOR LED DOWN 411 L 12 20 1 1 20 12 R 902 MOSAIC PW. SUPPLY #2 16 17 19 21 SPARE / B LA 14 -- ,.,. /», - 3 3:33.::.3:::.::33.3:,..;,::; - 20 1 1 20 - - -- SPARE 18 1 2 0 SPAR E 20 1 20 - SPARE 22 23 25 :; :3%Y: Jf:'�'l%3�� ::`%, �.:fr.. ,/». �'B :�:'''.33%33: ;,3, 3333'3 ,:-:- ..,5.!�'.++Y•., f43'/:3�3 ».; '��.`f%:.u.53�'�..f.. ';'% <.,:: MENEM :3;33i!µ+/.9 ':::if4i: 2 40 8 M 3000 WATER HEATER 24 3000 26 27 29 31 ..,.,.:,,,::.,.,.,:,,:,•:.::::::,,.:?t+','#`"'``zs`:>> :,..:..::;.;.::;;,.:::»:.:;.::::•::.::::.:..::.:::::::<..::.:.::::;.:.:. >�_ :;';',>':;::<.: r+r+'3:+:; ,:: 1 20 SPARE 28 - - - SPARE 30 1 20 - - -- SPARE 32 33 5 3; :f»•,.,»,•».»»».»»»,»»,.»,,++++::!+.w:333x::�x;::3 <;3:, s:'<f%k:%:: ;�:c3. .. `s's"'':` :i's>::++t:;::� sf?:µ`R, <;'s's?ui!::;�::::>:':.'ww:�<::'ei:+;: i�a;j"i i<'>3iii!i# � 1 20 12 M 660 FPVAV 34 1 20 - - - SPARE 36 37 <s3:�: ,..<. ;%»:.::. ,!<s'syc::.<. 3:3�%„3' <>4�y s>''3ss 3's's%'%'s' !'1.+.Y!�+f+i`•: J'; :iA+n+.':.: :3:•'.Y,y�3.++�Y • :rFh :�'.+4'i �`: : ,,:t..<f,ry ' ,,. :,» 3;;:3•:::i;3:;:»3;,;333#; ,';r?>;'s: <3#3!': 38 3%... {( ..��yy�� :::.i.'.:. »» .: ,..f,:.'s!fY..: ...»: f », :tfA4: ::ufY!:: k::;vi4:.3'/.: 3: �33,3,�/.3�: 33.::iYy::l:; /f 3 ::f3l3Y.if'f.- ::...�}✓f ',Y/.. r ':' ^% �: f.•r� t:3:»,/'•33'..'3333333"r:�:'4:33::5'.�:' �tl%1....../ , 4 41 MIMI -33 42 4790 5069 4918 SUB TOTALS L = LTG OR SIGNAGE R = RECEPTACLE CONNECTED LOAD 14777 M = MISCELLANEOUS H = H.V.A.C. PHASE BALANCE ___ 5.5X K = KITCHEN NOTE: ALL BREAKERS SHALL BE BOLT -ON, UNLESS OTHERWISE NOTED. 0 - INDICATES THIS CIRCUIT TO RECIEVE HANDLE LOCK -ON CLIP �k - REFER TO ONE -LINE DIAGRAM FOR WIRE SIZE TO THIS EQUIPMENT mik fR rm-. SCHEDULE LAMP SCHEDULE QTY SYMBOL TYPE MANUFACTURER CATALOG NO. DESCRIPTION NOTES VOLTS REC SUR PEN WAL LAMP/ LAMP/ FIXTURE MANUFACTURER/ ow 12 ® CA JUNO 2 ICIALEDG4-6-1 4" DOWN LIGHT W/WHITE TRIM 1 120 X 1 10.2 11 L.E.D. 4 OLEDG43OK6WH 3 ® E4 LIGHTOLIER MIGN-25-LC-UN RECESSED EMERGENCY WITH 90 4,7 120 X 2 25 50 MINUTE LEAD CALCIUM BATTERY -- 36ft L1 AION LED 4024-92-LE 4000 SERIES LED LIGHTING WITH 1 120 X 2 2'8W 126 -- D100-Z-24 0-10V DIMMABLE LED DRIVER /FT -- SPPLS600K3OU1212 LED SQ CORNER LIGHTING SHEETS 5W --f L2 COOLEDGE EDRV030WUNV- 4n 0-10 D MMABL LED DRIVER 1 120 X 2 FTSQ 48ft L3 AION LED 8924-RGBW 8924 RGBW SERIES LED LIGHTING 1 120 X 2 5.8W 126 SERIES WITH LED DRIVER /FT -- 4 o R1A JUNO TLR2WH MINIATURE SINGLE CIRCUIT 1 12 X NOT APPLICABLE 24 TRACK 2 R2A JUNO TLR4WH MINIATURE SINGLE CIRCUIT 1 12 X NOT APPLICABLE 48 TRACK 4 R4A JUNO TLR8WH MINIATURE SINGLE CIRCUIT 1 12 X NOT APPLICABLE 96 TRACK 6 - S1A JUNO TLR38WH LIVE END POWER FEED WHITE FINISH 1 120 X NOT APPLICABLE 4 S2A JUNO TLR50WH CENTER "MINI -CONNECTOR 1 120 X NOT APPLICABLE WHITE FINISH 6 ® S3A JUNO TL549N-BL 12V REMOTE MOUNT 1 120 X NOT APPLICABLE MAGNETIC TRANSFORMER 30 ® TA JUNO TL252L-3-S-WH TRAC 12" LED 1 12 X 1 13 13 L.E.D. CYLINDRA SPOTLIGHT TRAC 12 LED 15 ® TB JUNO TL252L-3-F-WH CYLINDRA SPOTLIGHT 1 12 X 1 13 13 L.E.D. 16 (III TC JUNO TL252L-3-NF-WH TRAC 12" LED 1 12 X 1 13 13 L.E.D. CYLIN RA SPOT IGHT -- T1 JUNO TL114G2-3-S-WH TRAC 12" LED 1 12 X 1 6.6 7 L.E.D. MINI -CYLINDER SPOTLIGHT -- T2 JUNO TL114132-3-F-WH TRAC 12" LED 1 12 X 1 6.6 7 L.E.D. MINI -CYLINDER FLOODLIGHT 2 ® X1A JUNO NXECRBA2RBA UNIVERSAL EDGE -LIT EXIT SIGN q�7 120 X -- -- 4 L.E.D. WITH 90MIN. INTERNAL BATTERY 1 ® X2A JUNO NXPCL3GWH UNIVERSAL MOUNT L.E.D. EXIT 4,7 120 X -- -- 5 L.E.D. SIGN W/90MIN. INTERNAL BATTERY 1. FIXTURES AND LAMPS SUPPLIED BY TENANT AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. EVI S lhllo 2. EQUIP NEW FLUORESCENT LIGHT FIXTURES WITH ELECTRONIC BALLASTS. t. 3. FIXTURES SHOWN WITH CROSS -HATCH ARE TO BE NIGHT LIGHTS WITH EMERGENCY BATTERY BALLAST. RECEIVED 4. FIXTURES USED FOR EXIT, EMERGENCY, OR NIGHT LIGHTING TO BE ON LOCKOUT CIRCUIT. CITY OF TUKWILA 5. GENERAL CONTRACTOR SHALL CLEAN AND RELAMP EXISTING FIXTURES TO REMAIN TO LIKE -NEW CONDITION. FIELD VERIFY LAMP TYPE. SEP 2.8 .2015 6. MOUNT TIGHT AS POSSIBLE TO CEILING. PERMIT CENTER 7. E.C. TO SUPPLY AND INSTALL ALL EXIT SIGNS. E.C. TO INSTALL ALL EMERGENCY LIGHTS. 8. E.C. TO INSTALL 90 MINUTE BATTERY BACKUP EMERGENCY BALLAST MODEL NUMBER B50 ON EMERGENCY FIXTURES. 2401 Utah Avenue South Seattle, Washington 98134 (206) 318-1575 THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORP. WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT I THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE(WHICH IS SUBJECT TO CHANGE AT ME AN D ND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER EX CE PTASSTATED ( ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. THIS DRAWING PREPARED UNDER MY SUPERVISION, AND I DISCLAIM ANY RESPONSIBILITY FOR THE EXISTING BUILDING, CONSTRUCTION ELEMENTS, SITE CONDITIONS, OR ANY DOCUMENT WHICH DOES NOT BEAR MY SEAL. 60897 REGISTE A HIT . tFREDERICK J. GOGUA WASHINGTON Architect: Frederick Goglia ARC VISION, INC. 1950 CRAIG RD. SUITE 300 - ST. LOUIS, MO 63146 Revision Schedule Rev Date By Descriptio 2 t09/15/15£ C ILL, OWNER, & HEALTH OCT 0 5 7.9 City tit t kwiia IL®lNG DIVISION ttf 00 00 rrW oo V C LO E ca S Z Q p /-1 a) CO U .tt7 a tjSd a 00 Cn cn Project #: 150384 Store #: 28357 Project M. 67553-002 Issue Date: 08/07/15 Design Manager: LISA DOYLE LEED ® AP: N/A Construction Documents: wsr>r Checked by: <; Sheet Title: �,�.,,�. ' �,,,. <;. „,, 5..,% '_FP ''*`tea $g; Y'c. �s,>,<, „». ,»,,. a,u9 .. �. � � % E ,'c -%.1 :.,. S �` yak 9 {,,,� Scale: As noted RAI 01,,Z, AX SECTION 16100 1. GEN A. APPLICABLE PROVISIONS OF AIA DOCUMENT A201, "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION", AND DIVISION 1 GENERAL CONDITIONS GOVERN WORK UNDER THIS SECTION AND ALL OTHER SECTIONS OF DIVISION 16. B. APPLICABLE PROVISIONS OF THIS SECTION GOVERN WORK UNDER ALL OTHER SECTIONS OF DIVISION 16. WORK COVERED BY THIS SECTION SHALL CONSIST OF PROVIDING ALL MATERIAL; LABOR, EQUIPMENT AND SERVICES NECESSARY FOR A COMPLETE, TESTED AND ADJUSTABLE ELECTRICAL INSTALLATION READY FOR OPERATION AS SPECIFIED HEREIN AND AS SHOWN ON THE DRAWINGS. C. THE TERM CONTRACTOR AS USED IN THIS SECTION SHALL MEAN ANY CONTRACTOR OR SUBCONTRACTOR WHO HAS CONTRACTED TO PERFORM WORK INCLUDED IN AND DEFINED BY THIS SECTION AND ALL OTHER SECTIONS OF DIVISION 16. 2. CONTRACTOR'S RESPONSIBILITY A. PRIOR TO SUBMITTING HIS BID, CONTRACTOR SHALL CAREFULLY EXAMINE THESE CONSTRUCTION DOCUMENTS, THE DEVELOPER'S EXHIBITS, AND THE SITE, TO INQUIRE FULLY INTO DIFFICULTIES AND COSTS OF WORK, AND TO DETERMINE THE SCOPE AND CHARACTER OF WORK TO BE DONE. CONTRACTOR SHALL INCLUDE ALL NECESSARY COSTS TO LOCATE AND/OR EXTEND ALL UTILITIES INCLUDING LIGHTING PANELS, POWER PANELS, ELECTRICAL SERVICE, PHONE SERVICE AND/OR MODIFY EQUIPMENT TO MEET THE INTENT OF THE CONTRACT DOCUMENTS. THE OWNER, OWNER'S AGENT, ARCHITECT, ENGINEER OR DESIGNER SHALL NOT BE RESPONSIBLE FOR FAILURE OF THE CONTRACTOR TO DETERMINE DIFFICULTIES AND COSTS IN THE PROJECT OR FOR HIS OVERLOOKING OF THE REQUIREMENTS. B. IF THIS CONTRACTOR DOES NOT CLEARLY UNDERSTAND THE PLANS AND SPECIFICATIONS, OR IF THERE ARE ANY REQUIREMENTS WHICH ARE AMBIGUOUS IN THE CONTRACTOR'S OPINION, HE SHOULD CALL THIS TO THE ATTENTION OF THE ARCHITECT PRIOR TO BIDDING, SINCE THIS CONTRACTOR WILL BE HELD RIGIDLY TO THE INTERPRETATIONS OF THE ARCHITECT AND ENGINEER. C. CONTRACTOR SHALL SCHEDULE HIS WORK IN COOPERATION WITH OTHER TRADES INSTALLING INTERRELATED WORK. ALL WORK SHALL BE SCHEDULED TO MAINTAIN SERVICE TO ALL REQUIRED AREAS DURING THE COURSE OF THE CONSTRUCTION EXCEPT FOR SHORT TERM PLANNED SHUTDOWNS, ANY OF WHICH SHALL BE PRE -SCHEDULED WITH THE OWNERS AGENT AND THE LANDLORD. 3. WORKMANSHIP AND GUARANTEE A. IN ENTERING INTO A CONTRACT COVERING THIS WORK, THE CONTRACTOR ACCEPTS THE SPECIFICATIONS, AND GUARANTEES THAT THE WORK WILL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. CONTRACTOR FURTHER GUARANTEES THAT THE WORKMANSHIP AND MATERIAL WILL BE OF THE BEST PROCURABLE AND THAT NONE BUT EXPERIENCED WORKMEN EXPERIENCED IN EACH PARTICULAR CLASS OF WORK WILL BE EMPLOYED. CONTRACTOR FURTHER GUARANTEES TO REPLACE AND MAKE GOOD AT HIS OWN EXPENSE ANY DEFECTS DUE TO FAULTY WORKMANSHIP OR MATERIAL WHICH MAY DEVELOP WITHIN ONE (1) YEAR AFTER FINAL PAYMENT AND ACCEPTANCE BY THE ARCHITECT. 4. CODES AND STANDARDS A. CONTRACTOR WILL COMPLY IN ALL RESPECTS WITH THE ADOPTED BUILDING CODES, APPLICABLE LAWS, ORDINANCES, AND REGULATIONS AS MAY APPLY ACCORDING TO THE RULING OF THE CONTROLLING PUBLIC OFFICIAL SHOULD THE CONTRACTOR PERFORM ANY WORK THAT DOES NOT COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE LAWS, ORDINANCES AND REGULATIONS, OR WHICH DOES NOT RECEIVE THE APPROVAL OF THE CONTROLLING PUBLIC OFFICIAL, HE SHALL BEAR ALL COSTS ARISING IN CORRECTING THE DEFICIENCIES. ALL ELECTRICAL EQUIPMENT SHALL BEAR THE UNDERWRITER'S LABORATORY LABEL. 5. FEES ON PERMITS A. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND MAKING PAYMENT FOR ALL FEES, PERMITS AND INSPECTIONS RELATING TO HIS WORK. 6. CONTRACT DRAWINGS A. THE DRAWINGS SHOW THE GENERAL ARRANGEMENT AND INTENT OF THE DESIGN AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONDITIONS AND THE WORK OF OTHER TRADES WILL PERMIT. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS, AND ACCESSORIES WHICH MAY BE REQUIRED, NOR IS IT IMPLIED THAT ALL CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE SYSTEMS OR BUILDING COMPONENTS HAVE BEEN INDICATED. THE CONTRACTOR SHALL INVESTIGATE ALL EXISTING CONDITIONS AFFECTING THE WORK AND ARRANGE HIS WORK ACCORDINGLY, PROVIDING SUCH FITTINGS, OFFSETS, ACCESSORIES AND DEVICES AS MAY BE REQUIRED. THE DRAWINGS AND SPECIFICATIONS ARE MUTUALLY COMPLEMENTARY, AND ANY WORK REQUIRED BY ONE BUT NOT BY THE OTHER SHALL BE PERFORMED BY BOTH. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL MATERIALS AND SERVICES REQUIRED FOR A COMPLETE AND WORKING PROJECT AT NO ADDITIONAL COST EVEN THOUGH EACH AND EVERY NECESSARY ELEMENT THEREOF IS NOT SPECIFICALLY IDENTIFIED HEREIN EACH AND EVERY NECESSARY ELEMENT THEREOF IS NOT SPECIFICALLY IDENTIFIED HEREIN. B. CONTRACTOR SHALL NOT SCALE FROM THE DRAWINGS BUT SHALL FOLLOW THE ARCHITECTURAL DRAWINGS OR EXISTING BUILDING CONDITIONS WHERE APPLICABLE, IN ESTABLISHING DIMENSIONS AND LINES OF RUN, SINCE DIMENSIONS ON THE FINAL ARCHITECTURAL DRAWINGS OR AT THE SITE MAY NOT COINCIDE WITH THOSE SHOWN ON THE ELECTRICAL DRAWINGS, THE CONTRACTORS SHALL VERIFY WITH THE DIMENSIONED ARCHITECTURAL DRAWINGS OR THE SITE CONDITIONS THE EXACT MATERIAL QUANTITIES AND LENGTHS NECESSARY. C. SIGNIFICANT DEVIATIONS OR CHANGES FROM THE DRAWINGS WHICH ARE REQUIRED TO ACCOMPLISH THE INTENT OF THE CONTRACT DOCUMENTS MUST BE REVIEWED WITH THE ARCHITECT AND APPROVED BEFORE PROCEEDING. 7. SHOP DRAWINGS A. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, FOUR (4) COPIES MINIMUM, FOR ALL MANUFACTURED PRODUCTS. EACH SHOP DRAWING SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO ASSURE THAT ALL DIMENSIONS, QUANTITIES, CONNECTIONS, CAPACITATES AND ACCESSORIES SHOWN ARE IN CONFORMANCE WITH THE CONTRACT DOCUMENTS, AND SHALL BE MARKED OR STAMPED TO CONFIRM THAT SUCH REVIEW WAS MADE AND COMPLIANCE WAS CONFIRMED. B. APPROVAL OF SHOP DRAWINGS BY THE OWNER, OWNER'S AGENT, ARCHITECT, ENGINEER OR DESIGNER, WILL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF COMPLYING WITH ALL TERMS OF THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR PERFORMANCE OF ALL EQUIPMENT PURCHASED, FOR PROPER FIT, AND OTHER DIMENSIONAL REQUIREMENTS. 8. RECORD DRAWINGS A. CONTRACTOR SHALL MAINTAIN AT THE JOB SITE ONE SET OF DOCUMENTS AS "RECORD DRAWINGS" FOR THE PURPOSE OF DAILY MARKING OF ALL SUBSTANTIAL REVISIONS TO THE DOCUMENTS INCLUDING BUT NOT LIMITED TO ELECTRICAL CHANGES, AND LOCATIONS OF UTILITIES, PANELBOARDS, DISCONNECTS, STARTERS AND OTHER DEVICES REQUIRING PERIODIC OPERATIONAL ATTENTION, ADJUSTMENT, OR SERVICE INCLUDING ACCESS THERETO, AT THE COMPLETION OF THE PROJECT, THIS SET SHALL BE RETURNED TO THE ARCHITECT FOR THE PURPOSE OF MAKING FINAL "AS -BUILT DRAWINGS". 9. EQUIPMENT SUBSTITUTION A. SPECIFIC MANUFACTURERS AND MODELS OF EQUIPMENT HAVE BEEN USED IN THE DEVELOPMENT OF THE DRAWINGS AND DESIGNS. THIS CONTRACTOR MUST SUBMIT TO THE OWNER ANY CHANGES AND/OR SUBSTITUTIONS FOR APPROVAL PRIOR TO INSTALLATION OR EXECUTION. ANY CHANGES WHICH DO NOT RECEIVE THE OWNER'S APPROVAL MAY BE SUBJECT TO REMOVAL OR REPLACEMENT AS ORIGINALLY SPECIFIED, AND WILL BE AT THE CONTRACTOR'S EXPENSE. B. IF THIS CONTRACTOR SUBSTITUTES FOR SPECIFIED EQUIPMENT ANY OTHER EQUIPMENT WHICH REQUIRES ANY CHANGES TO THE DESIGN, ALL COST OF REDESIGN AND RECONFIGURATION RESULTING FROM SAID SUBSTITUTION SHALL BE BORNE BY THE SUBMITTING CONTRACTOR. 10. EQUIPMENT INSTALLATION AND SUPPORT A. CONTRACTOR SHALL SUPPORT PLUMB, RIGID AND TRUE -TO -LINE ALL WORK AND EQUIPMENT INSTALLED. THIS CONTRACTOR SHALL DETERMINE HOW EQUIPMENT, FIXTURES, ETC., ARE TO BE SUPPORTED, MOUNTED, OR SUSPENDED AND SHALL PROVIDE ACCESSORIES REQUIRED FOR PROPER SUPPORT WHETHER SHOWN ON THE DRAWINGS OR NOT. IF SUPPORTS..ARE REQUIRED, CONTRACTOR SHALL SUBMIT DRAWINGS TO THE ARCHITECT FOR APPROVAL. B. PRODUCTS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS PRINTED INSTALLATION AND MAINTENANCE LITERATURE. COMPONENTS REQUIRING PERIODIC MAINTENANCE OR ADJUSTMENTS SHALL BE LOCATED OR INSTALLED AS TO PERMIT ACCESS WITHOUT DAMAGE TO STRUCTURE, FINISHES OR OTHER EQUIPMENT. C. ALL CONDUIT CONNECTING TO SWITCHGEAR, PANELS, MOTORS, AND OTHER EQUIPMENT SHALL BE INSTALLED WITHOUT STRAIN AT THE CONNECTIONS. THE CONTRACTOR MAY BE REQUIRED, AS DIRECTED, TO DISCONNECT CONDUITS TO DEMONSTRATE THAT THEY HAVE BEEN SO CONNECTED 11. DEMOLITION A. ALL EXISTING EQUIPMENT, NOT INDICATED TO BE INCORPORATED INTO THE NEW SYSTEM SHALL BE DISCONNECTED BY THIS CONTRACTOR FOR REMOVAL BY OTHERS FROM THE JOB SITE. CARE SHALL BE USED SO THAT NO DAMAGE IS DONE TO EXISTING BUILDING, PIPING, DUCTWORK, AND/OR ELECTRICAL EQUIPMENT. ANY DAMAGE ATTRIBUTED TO THIS CONTRACTOR SHALL BE REPAIRED OR REPLACED BY THIS CONTRACTOR. 12. CUTTING AND PATCHING A. ALL CUTTING THAT MAY BE NECESSARY FOR THE INSTALLATION OF THE WORK OR ANY REQUIRED PATCHING THAT RESULTS THEREFROM SHALL BE DONE BY THE PROPER TRADE INVOLVED AND SHALL BE INCLUDED AS PART OF THIS CONTRACT. PATCH TO DUPLICATE UNDISTURBED ADJACENT FINISHES, COLORS, TEXTURES AND PROFILES. COLUMNS, BEAMS, GIRDERS OR JOISTS SHALL NOT BE CUT. B. ALL WORK AFFECTING ROOF OR STRUCTURES SHALL BE PERFORMED BY LANDLORD'S CONTRACTOR AT TENANT'S EXPENSE. 13. CLEANING A. COMPLETION AS IT PERTAINS TO THE CONTRACT COMPLETION DATE IS DEFINED AS THE DAY THE PROJECT IS TURNED OVER TO THE OWNER IN THOROUGHLY CLEAN CONDITION. READY FOR THE OWNER TO TAKE POSSESSION. ALL FIXTURES, MOTORS, EQUIPMENT AND ALL OTHER ELECTRICAL EQUIPMENT FURNISHED OR INSTALLED BY THE CONTRACTOR SHALL BE THOROUGHLY CLEANED. 14. IE:sT.S A. PROVIDE THE TESTS AS OUTLINED HEREINAFTER AND OTHER TESTS NECESSARY TO ESTABLISH THE ADEQUACY, QUALITY, SAFETY, COMPLETED STATUS AND SUITABLE OPERATION OF EACH SYSTEM. CORRECT PROMPTLY ANY FAILURE OR DEFECTS REVEALED BY THESE TESTS AND RECONDUCT TEST ON THE CORRECTED ITEMS. B. TEST THE GROUNDS WITH A GROUND RESISTANCE DIRECT READING SINGLE -TEST MEGGER. C. INSULATION RESISTANCE BETWEEN PHASE CONDUCTORS AND GROUND NOT LESS THAN 1,000,000 OHMS. D. THE PANELBOARDS SHALL HAVE PHASE CURRENTS BALANCED TO WITHIN +/- 10% VARIATION BETWEEN AVERAGE PHASE CURRENT AND MEASURED INDIVIDUAL PHASE. E. AN OPERATIONAL TEST OF THE EMERGENCY LIGHTS AND THE EXIT LIGHTS SHALL BE PERFORMED FOR THE OWNER TO DEMONSTRATE CONFORMANCE TO THE SPECIFICATIONS. 15. TEMPORARY ELECTRICAL SERVICE BY E.C. A. TEMPORARY ELECTRICAL SERVICE SHALL BE IN ACCORDANCE WITH THE BUILDING CODE. TEMPORARY LIGHTING SHALL BE PROVIDED BY A LAMP LOCATED FOR EVERY 625 SQUARE FEET OF BUILDING AREA WITH A MINIMUM OF ONE PER ROOM. THE LAMP TO BE 100 WATT AND SHALL BE MAINTAINED BY THE GENERAL CONTRACTOR. B. TEMPORARY POWER DISTRIBUTION SHALL BE SUFFICIENT TO ACCOMMODATE THE TEMPORARY LIGHTING AND CONSTRUCTION OPERATIONS, INCLUDING THE USE OF POWER TOOLS (BUT NOT INCLUDING HEAVY-DUTY ELECTRICAL WELDING UNITS), ELECTRICAL HEATING UNITS, AND START-UP OF SPECIFIED BUILDING EQUIPMENT, WHICH IS TO BE TESTED, STARTED OR PLACED INTO OUR USE PRIOR TO COMPLETION OF ITS PERMANENT POWER CONNECTIONS. 16. EXCAVATION AND BACKEI A. CONTRACTOR SHALL DO ALL EXCAVATION REQUIRED AS SHOWN ON PLANS OR REQUIRED FOR PROPER OPERATION. EXCESS EXCAVATION BELOW THE REQUIRED LEVEL SHALL BE BACKFILLED WITH EARTH AND THOROUGHLY TAMPED. UTILITY SERVICES, SHALL BE INSPECTED AND APPROVED BY THE PROPER INSPECTION AUTHORITY BEFORE BACKFILLING. 1 150 ELECTRICAL POWER AND 1. RELATED DOCUMENTS A. APPLICABLE PROVISIONS OF AIA DOCUMENT A201, "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION", DIVISION 1 GENERAL CONDITIONS AND SECTION 16100 ELECTRICAL SPECIAL CONDITIONS GOVERN WORK UNDER THIS SECTION. B. REFER TO SECTION 16100 ELECTRICAL SPECIAL CONDITIONS REGARDING REGULATIONS AND REQUIREMENTS AFFECTING ALL WORK DESCRIBED IN THIS SECTION. 2. POWER SERVICE - REFER TO ONE-UNE DIAGRAM. A. POWER SERVICE FOR THIS PROJECT SHALL BE PROVIDED FROM THE EXISTING MALL DISTRIBUTION SYSTEM. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MALL MANAGEMENT TO INSURE THAT ALL WORK AND MATERIALS ARE IN CONFORMANCE WITH THE LANDLORD'S STANDARDS. 3. NAMEPI ATFS A. ELECTRICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO, PANELBOARDS, DISCONNECTS TRANSFORMERS, CONTROLS, ETC., SHALL BE IDENTIFIED WITH THREE PLY LAMINATED PLASTIC. THE OUTSIDE LAMINATIONS SHALL BE BLACK. ENGRAVING SHALL EXTEND THROUGH THE FRONT LAMINATION SO THAT THE BLACK LETTERS APPEAR ON A WHITE BACKGROUND. NAMEPLATES SHALL BE PERMANENTLY ATTACHED WITH SCREWS. B. CIRCUIT DIRECTORY SHALL BE TYPEWRITTEN (HANDWRITTEN IS NOT ACCEPTABLE) AND SHALL IDENTIFY CIRCUIT AS TO TYPE AND LOCATION AS FOLLOWS: "LTG" - FOR LIGHTING CIRCUIT FOLLOWED BY AREA IN WHICH CIRCUIT APPEARS, I.E., "STOCKROOM", "CASH WRAP",, ETC. "RECEPT" - FOR RECEPTACLE CIRCUIT FOLLOWED BY AREA IN WHICH RECEPTACLE APPEARS, "STOREFRONT", "CASH REGISTER", ETC. "MOTOR" - FOR MOTOR FOLLOWED BY THE EQUIPMENT IDENTIFICATION AND AREA IN WHICH MOTOR IS LOCATED, I.E. "EXH FAN TOILET", "AHU-ROOF", ETC. 4. .CONDl1T A. ALL WIRING SHALL BE RUN IN CONDUIT. THIN WALL EMT CONDUIT SHALL BE FOR SIZES 1 /2" THROUGH 2-1/2". ALL CONDUITS LARGER THAN 2-1/2" SHALL BE HEAVYWALL. CONDUITS INSTALLED UNDERGROUND OR IN CONCRETE SLABS SHALL BE PVC JACKETED FLEXIBLE STEEL CONDUIT (SEALTITE) SHALL BE USED IN WET AREAS AND ON ALL MOTORIZED EQUIPMENT. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS, AT A MAXIMUM LENGTH OF 6 FEET. NO BX, ROMEX, ARMORED CABLE, ETC. SHALL BE ALLOWED. B. ALL OPENINGS IN FIRE AND SMOKE WALLS, PARTITIONS, FLOORS AND OTHER SIMILAR PENETRATIONS FOR ELECTRICAL CONDUITS, CABLE OR EQUIPMENT, WHETHER CUT OR IN PLACE, SHALL EE CLOSED WITH A UL APPROVED FIRE RESISTANT SILICONE FOAM SEALANT TO MAINTAIN THE FULL RATING AND INTEGRITY OF THE PARTITIONS, WALLS OR FLOOR. C. CONDUIT BENDS FOR POWER AND LIGHTING CIRCUITS SHALL NOT BE LESS THAN STANDARD RADIUS BENDS. CONDUIT BENDS FOR FEEDERS, TELEPHONE AND COMMUNICATION CIRCUITS SHALL NOT BE LESS THAN LONG RADIUS BENDS. D. O.Z. TYPE DX, TX, OR AX CONDUIT EXPANSION DEFLECTION FITTINGS ARE REQUIRED IN ALL CONDUIT RUNS WHERE MOVEMENT MAY BE ENCOUNTERED. ALL EMT COUPLINGS SHALL BE COMPRESSION TYPE. E. EXPOSED CONDUIT SHALL BE SECURELY SUPPORTED IN PLACE PER CODE BUT ON A MAXIMUM OF 10 FOOT INTERVALS, WITHIN THREE FEET OF EACH BEND, AT EVERY OUTLET OR JUNCTION BOX AND AT THE END OF EACH STRAIGHT RUN TERMINATING AT A BOX OR CABINET. CONDUIT SHALL NOT BE SUPPORTED FROM DUCTWORK OR PIPE WORK. CONDUITS SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO THE BUILDING LINES. GENERALLY, CONDUIT SHALL BE RUN IN CONTACT WITH STRUCTURAL PARTS OF THE BUILDING SO AS TO AVOID SUSPENDED LENGTHS OF CONDUIT. CONDUIT SHALL BE INSTALLED AS TO BE ACCESSIBLE FOR REPLACEMENT AND MAINTENANCE AND GENERALLY CONDUIT SHALL BE INSTALLED TO PERMIT DRAINAGE. 5. WIRE AND CABLE (COPPER ONLY) A. ALL WIRE AND CABLE SHALL BE RUN IN CONDUIT. ALL WIRE AND CABLE FEEDERS AND BRANCH CIRCUITS SHALL CONFORM TO THE LATEST REQUIREMENTS OF THE CURRENT EDITION OF THE N.E.C. AND SHALL MEET ALL ASTM SPECIFICATIONS. WIRE AND CABLE SHALL BE NEW, SHALL HAVE SIZE, GRADE OF INSULATION VOLTAGE AND MANUFACTURER'S NAME PERMANENTLY MARKED ON OUTER COVERING AT REGULAR INTERVAL AND SHALL BE DELIVERED IN COMPLETE COILS OR REELS WITH IDENTIFYING SIZE AND INSULATION TAGS. B. THE ELECTRICAL CONTRACTOR SHALL CALCULATE VOLTAGE DROP ON CONDUCTORS WITH LENGTHS GREATER THAN 75 FEET FROM THE PANELBOARD AND PROPERLY SIZE THE CONDUCTORS PER N.E.C. C. POWER CONDUCTORS: NO WIRE LESS THAN NO. 12 SHALL BE USED EXCEPT FOR CONTROL CIRCUITS OR LOW VOLTAGE WIRING. WIRE SIZES NO. 12 TO NO. 10 SHALL BE SOLID EXCEPT WHERE OTHERWISE INDICATED. WIRE SIZES NO. 8 AND LARGER SHALL BE STRANDED. ALL WIRE SIZES SHOWN ARE AMERICAN WIRE GAUGE SIZES. SIZES NO. 12 AWG THROUGH NO. 8 AWG SHALL BE "THHN." SIZE 4 AWG AND LARGER SHALL BE "THW." D. CONTINUITY: ALL WIRES SHALL BE CONTINUOUS FROM OUTLET TO OUTLET. E. ACCEPTABLE MANUFACTURERS: CABLE AND WIRE SHALL BE STANDARD TYPE AS MANUFACTURED BY GENERAL CABLE COMPANY, CAROL, ANACONDA, ROM OR ITT ROYAL. F. E.C. TO PROVIDE & INSTALL CAT 5 CABLE TO FAX MACHINE & CASHWRAP LOCATION CABLE TO TERMINATE AT PHONE PANEL BOARD LOCATION IN STOCKROOM. 6. COLOR CODING A. A COLOR CODING SYSTEM AS LISTED BELOW SHALL BE FOLLOWED THROUGHOUT FOR FEEDERS AND BRANCH CIRCUITS AND USED AS A BASIS FOR BALANCING LOAD. --120/208V: PHASE A --BLACK, PHASE B--RED, PHASE C--BLUE, NEUTRAL --WHITE, GROUND--GREEN --277/48OV: PHASE A --BROWN, PHASE B--ORANGE, PHASE C--YELLOW, NEUTRAL --GRAY, GROUND --GREEN 7. BOXES AND FITTINGS A. ALL OUTLETS SHALL BE PROVIDED WITH GALVANIZED OR SHERARDIZED BOXES SUITABLE IN DESIGN TO THE SPACE THEY OCCUPY AND THE PURPOSE THEY SERVE. WALL MOUNTED OUTLET BOXES, EXCEPT FOR 2" PARTITIONS SHALL BE AT LEAST 1 1 /2" DEEP AND/OR DEEPER IF REQUIRED BY THE DEVICE THE( HOLD OR THE NATIONAL ELECTRICAL CODE. B. ALL PULLBOXES SHALL BE MADE OF GALVANIZED STEEL, OF METAL GAUGE AND PHYSICAL SIZE AS REQUIRED BY ThE NEC FOR THE NUMBER AND SIZE OF RACEWAYS AND CONDUCTORS INVOLVED. C. FIXTURE OUTLET BOXES IN OR ON CEILINGS SHALL NOT BE LESS THAN 1-1/2" DEEP OR LESS THAN 4" SQUARE. ALL OUTLET BOXES INTENDED TO SUPPORT FIXTURES SHALL BE EQUIPPED WITH 3/8" FIXTURE STUDS FASTENED THROUGH THE BOTTOM OF THE BOX WITH FOUR BOLTS. 8. CIRCUIT BREAKER PANELBOARDS A. PANELS SHALL BE DEAD FRONT, SAFETY TYPE, FURNISHED WITH BRANCH CIRCUIT PROTECTING DEVICES, EQUIPMENT GROUNDING BOX, MAIN BUS AND CABLE LUGS FACTORY ASSEMBLED, WITH ALL COMPONENTS IN PLACE, READY FOR INSTALLATION. PROVIDE 20% SPARE BREAKER CAPACITY AND 25% EXCESS AMPACITY IN EACH PANEL. B. CURRENT CARRYING CONTACT SURFACES SHALL BE SILVER OR TIN PLATED. THE CIRCUIT BREAKERS SHALL BE OF THE MOLDED CASE, BOLT -ON TYPE SUITABLE FOR VOLTAGE AND AMPERE RATINGS INDICATED ON DRAWINGS AND IN SCHEDULES AND SHALL HAVE A MINIMUM INTERRUPTING CAPACITY OF 10,000 AMPERES FOR 120/208V AND 14,000 AMPERES AT 277/48OV. C. MAIN BUSES AND CONNECTORS SHALL BE HARD DRAWN COPPER OF 98% CONDUCTIVITY, WITH CURRENT CARRYING CAPACITY TO MAINTAIN ESTABLISHED RISE TESTS AS DEFINED IN UL STANDARD UL 67. D. CABINET SIZES ARE BASED UPON A 20" WIDE BY 6" DEEP PANEL UNLESS OTHERWISE NOTED. PANELBOARDS SHALL BE EQUIPPED WITH FLUSH TYPE LOCK AND CATCH. ALL LOCKS SHALL BE KEYED ALIKE, AND TWO KEYS ARE TO BE SUPPLIED WITH EACH LOCK. E. PANELBOARDS TO BE BY SQUARE D CORPORATION, GENERAL ELECTRIC, OR WESTINGHOUSE. 9. TRANSFORMERS A. DRY -TYPE TRANSFORMERS SHALL BE OF THE ENCLOSED VENTILATED TYPE WITH KVA AND VOLTAGE RATING AS CALLED FOR ON THE DRAWINGS AND WITH 150' CLASS H INSULATION AND MINIMUM OF SIX STANDARD FULL CAPACITY TAPS. SOUND LEVEL SHALL BE LOW AND INSTALLATION SHALL INCLUDE KORFUND OR EQUAL VIBRATION DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY. (MOUNT TRANSFORMER ON VIBRATION ISOLATORS). LOCATE TRANSFORMER AS NOT TO CAUSE SERVICING OR CLEARANCE DIFFICULTIES OF VIOLATIONS WITH OTHER EQUIPMENT. B. COMPARABLE EQUIPMENT AS MANUFACTURED BY SQUARE D CORPORATION OR GENERAL ELECTRIC 10. TOGGLE SWITCHES A. TOGGLE SWITCHES SHALL BE WHITE AND SHALL BE RATED 20 AMPERES 120/277 VOLT AC TYPE AS MANUFACTURED BY HUBBELL AND SHALL BE AS FOLLOWS: SINGLE POLE--1221--1 THREE WAY--1223--1 B. TOGGLE SWITCHES SHALL BE MOUNTED 4'-0" ABOVE FINISHED FLOOR TO MOUNTING PLATE AND, AT DOORS, INSTALLED ADJACENT TO THE TRIM ON THE STRIKING SIDE OF THE DOOR, REGARDLESS OF THE LOCATION INDICATED ON THE DRAWINGS; THEREFORE, CHECK ALL DOOR SWINGS BEFORE INSTALLATION OF CONDUIT OUTLETS. C. COMPARABLE EQJIPMENT AS MANUFACTURED BY SLATER, LEVITON, AND BRYANT WILL BE ACCEPTABLE. 11. RECEPTAC U A. RECEPTACLES Sl-ALL BE WHITE. UNLESS OTHERWISE NOTED AS MANUFACTURED BY HUBBELL AND SHALL BE AS FOLLOWS: DUPLEX RECEPTACLE--20A-120 VOLT 5362 B. RECEPTACLES SHALL BE MOUNTED 15" ABOVE THE FINISHED FLOOR UNLESS OTHERWISE NOTED. C. COMPARABLE EQUIPMENT AS MANUFACTURED BY SIERRA ELECTRIC CORPORATION, SLATER, BRYANT AND LEVITON WILL BE ACCEPTABLE. 12. DEVISE PLATES A. DEVICE PLATES SHALL BE WHITE UNLESS OTHERWISE NOTED. COMPARABLE EQUIPMENT AS MANUFACTURED BY SIERRA ELECTRIC CORPORATION, HARVEY HUBBELL INC., BRYANT AND LEVITON WILL BE ACCEPTABLE. PAINT MATCH ADJACENT FINISH COLOR. 13. DISCONNECT SWITCHES A. FURNISH AND INSTALL DISCONNECT SWITCHES AS REQUIRED BY CODE. DISCONNECT SWITCHES SHALL BE NEMA HEAVY DUTY TYPE AND UNDERWRITERS LABORATORIES LISTED, MANUFACTURED BY SQUARE D CORPORATION, ITE, GENERAL ELECTRIC, OR WESTINGHOUSE. 14. GROUNDING A. CONTRACTOR SHALL INSTALL A SYSTEM GROUNDING SYSTEM AND AN EQUIPMENT GROUNDING SYSTEM AND SHALL USE ONLY APPROVED GROUNDING CLAMPS AND CONNECTORS AS MANUFACTURED BY PENN-UNION, BURNDY, OR O-Z MFG. COMPANY. B. THE SYSTEM GROUNDING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND THE UTILITY COMPANY REGULATIONS. CONTRACTOR SHALL CONNECT THE GROUNDING ELECTRODE CONDUCTORS TO THE NEUTRAL BAR INSIDE THE MAIN PANEL. WHEN TRANSFORMERS ARE USED TO PROVIDE A SEPARATELY DERIVED SYSTEM, THE CONTRACTOR SHALL CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE NEUTRAL BAR INSIDE THE SECONDARY SYSTEM PANEL OR SERVICE RATED DISCONNECT SWITCH, DO NOT CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE NEUTRAL LUG INSIDE THE TRANSFORMER. C. THE EQUIPMENT GROUNDING SYSTEM SHALL CONSIST OF A CONTINUOUS CONDUIT INSTALLATION AND A GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR. THIS GROUNDING CONDUCTOR SHALL BE INSTALLED IN EVERY CONDUIT OR RACEWAY WITH THE FEEDER OR BRANCH CIRCUIT CONDUCTORS. THIS GROUNDING SHALL BE EXTENDED FROM THE HOUSING OF EVERY ELECTRICAL LOAD, THROUGH PANELBOARD STATIC GROUNDING BUSSES, TO THE STATIC GROUNDING BUS IN THE MAIN PANEL. THE GROUNDING BUS SHALL BE BONDED TO THE GROUNDING NEUTRAL BAR INSIDE THE MAIN PANEL. 15. LIGHTING FIXTURES A. ALL LIGHTING FIXTURES AND LAMPS SHALL BE FURNISHED BY OWNER, UNLESS NOTED OTHERWISE. THIS CONTRACTOR SHALL INSTALL LIGHTING FIXTURES AND LAMPS AS INDICATED ON THE DRAWINGS AND AS SPECIFIED BELOW, COMPLETE WITH HANGERS, PLASTER FRAMES AND ALL OTHER NECESSARY ACCESSORIES. B. ALL BALLAST, STARTERS AND LAMPHOLDERS IN FLUORESCENT LIGHTING EQUIPMENT ARE TO BE ELECTRICAL TESTING LABORATORIES, UNDERWRITERS LABORATORIES AND CERTIFIED BALLAST MANUFACTURERS APPROVED. ALL BALLAST FOR FLUORESCENT FIXTURES SHALL BE OF THE HIGH POWER FACTOR TYPE AND SHALL BE GENERAL ELECTRIC MAXI MISER II OR ADVANCED MARK III. WHERE OCTRON LAMPS ARE SPECIFIED PROVIDE APPROPRIATE BALLASTS. C. THIS CONTRACTOR SHALL VERIFY THE FINAL CEILING AND FINISH SCHEDULES TO INSURE THE PROPER INSTALLATION AND MOUNTING OF FIXTURES AND SHALL COORDINATE BEFORE MAKING SUBMITTALS. 16. TIMECLOCKS f CONTACTORS A. TIMECLOCKS SHALL BE CALIFORNIA ENERGY COMMISSION APPROVED TORK DIGITAL DTS400B 4 CHANNEL WITHOUT ASTRONOMIC APPLICATIONS OR EQUAL .IN ALL STATES. B. LIGHTING CONTACTORS SHALL BE SQUARE D "TYPE L" C. OPERATING HOURS SHALL BE SET AS FOLLOWS: 1. FOR STRIP CENTERS: SET INTERIOR TIMECLOCKS TO 7:OOAM TO 11:00PM AND STOREFRONT EXTERIOR SIGNAGE TO 5:OOPM TO 11:OOPM 2. FOR MALLS: SET ALL TIMERS TO 8:OOAM TO 11:OOPM. COORDINATE WITH MALL REQUIREMENTS 17. TELEPHONE SERVICE A. THIS CONTRACTOR SHALL INSTALL A TELEPHONE SERVICE CONDUIT AS SHOWN ON THE DRAWINGS AND FURNISH AND INSTALL (1) 2' X 2' X 3/4" PLYWOOD PANEL MOUNTED ON THE WALL AT LOCATION SHOWN ON PLANS. CONTRACTOR SHALL ALSO FURNISH AND INSTALL CAT 5 CABLE END OF DIVISION 16 RECEIVED CITY OF TUKWILA SEP 2.8 2015 PERMIT CENTER 2401 Utah Avenue South Seattle, Washington 98134 (206) 318-1575 THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORP. WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FORA PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THEOTHER (EXCEPTASSTATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. THIS DRAWING PREPARED UNDER MY SUPERVISION, AND I DISCLAIM ANY RESPONSIBILITY FOR THE EXISTING BUILDING, CONSTRUCTION ELEMENTS, SITE CONDITIONS, OR ANY DOCUMENT WHICH DOES NOT BEAR MY SEAL. 6897 R GiST D' AyHI E FREDERICK J. GOGLIA STATE OF WASHINGTON Architect: Frederick Goglia ARC VISION, INC. 1950 CRAIG RD. SUITE 3D0 - ST. LOUIS, MO 63M Revision Schedule Rev Date By ' Description ! .....� ...._...........__, m.. , r...,... _..., _ ._.._. 3 „09�23/1,51 CW 1OWNER COMMENTS ................................... ..... ..,............................... ..._....... ...... .._............,................. __.........s......_........................................ . a ....... � _.......,m ...., a.............. ..... �....�.... �........�...µ........... 5.. ..........................= .......m..mwx..i...xmx. �..�..� -RE--VI' W'EIY ..... __.. ........ ................ vMiM OF C®IUIPLIANCE WITH NFPA 70 - N1=C OCT 0 5 2015 City of �TUkWila BUI G DIVISION W Z co 00 W U CD oo 0) N = (,DU C Q Z Q c .3 v v O U) (0 U co Cl- Xi 000 to I - Project #: 150384 Store #: 28357 Project #: 67553-002 Issue Date: 08/07/15 Design Manager: LISA DOYLE LEED®AP: N/A Construction Documents: CW Checked by: TJ Sheet Title: ELECTRICAL SPECIFICATIONS N rIz W ca 0 THE CONTRACTOR FOR THIS WORK IS REQUIRED SPECIFICATION AND REVIEW DRAWINGS FOR ALL A COMPLETE ONDERSTANDING OF THIS PROJECT 0 Scale: As noted L C_ ro a> n a b c d ❑ ❑ o a LP-1 LP-5 LP-9 LP-9 SALES SALES UNDER SALES GENERAL TRACK SELF LED UP/DOWN LIGHTING LIGHTING DIMMER DIMMER McC)I>ftOt�e, C3 Electrical AXPlum Bing as Pipings LiGNGPLAN Ct*7 of Tukwila 1 u4! ►' tN1N-0 DIVISION SCALB - r-0 NOTE: LIGHT FIXTURES IN FOOD PREPARATION, OPEN FOOD STORAGE AND UTENSIL WASHING AREAS ARE TO BE OF SHATTER -PROOF PROTECTED AGAINST BREAKAGE THROUGH THE SE OF PLASTIC IGHT SHIELDS OR OTHER APPROVED DEVICES. Nv Z # be m to the scope+af wet` �01 it prior M.4 r t of`Tiik� ►''#�i g,.;ldi" ign. i FILE COPY e Permit No..i Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the v1da Lion of any adopted Code or ordinance. Receipt Of approved Field Copy and conditions its acknowledged: Date: 7 _12 �/ 5� (City of Tuk%vila BUILDING DIVISION e f 9 Q❑ GENERAL LTG LP LP-9 01 TABLE TABLE LED TAPE LGT BOX DIMMER DIMMER SPRING WOUND MANUAL BYPASS DEDICATED TIMER WITH 0-2 HOUR RANGE WITHOUT HOLD FEATURE FOR GENERAL LIGHTING CONTACTOR DUPLEX RI PARAGON #ETPD/120 2450 FOR POS CONTRACTOR TO VERIFY EXACT CONFIGURATION SEE PLAN REQUIRED WITH SPACE AVAILABLE. PROVIDE FOR LOCK LABELS AS DIRECTED BY OWNER. SWITCHES SHALL NOT BE MOUNTED HIGHER THAN 48" :XISTING YPICAL LP-9c YPE "T1" YPICAL YPE '72" YPICAL LP-9 TYPICAL TYPE "CA" (YPICAL J-BOX FOR DATA J-BOX FOR PHONE ., fiNt ;,. LP-9e,f LP-6,10� HE SURFACE MOUNTED RECEPTACLE C) UNIPLEX RECEPTACLE (SINGLE) 6 DUPLEX RECEPTACLE DUPLEX ISOLATED GROUND QUADPLEX RECEPTACLE QUADPLEX ISOLATED GROUND ® SPECIAL VOLTAGE OR AMPERAGE ® TELEPHONE OUTLET JQ JUNCTION BOX DATA OUTLET EI DOORBELL PUSHBUTTON a DOORBELL ® DOORBELL LOW -VOLT TRANS © LOW -VOLTAGE TRANSFORMER ❑I DISCONNECT SWITCH ©i TRAFFIC COUNTER TELEPHONE BOARD ELECTRICAL PANEL KVA TRANSFORMER N 24HR 7 DAY —TIME CLOCK $ WALL SWITCH os CEILING OCCUPANCY SENSOR 3 #12, 3/4"C (2 CKT WIRES, 1 NEUTRAL, 1 GROUND) CIRCUIT HOME RUN - - - - CONDUIT THRU/BELOW FLOOR o— CONDUIT STUBBED UP/DOWN N.L. NIGHT LIGHT VIA T/C TIMECLOCK CONTROLED CIRCUIT PP-8,10 PP-2 -12 LP-14, LP-22 LP-12 PP-1 PP-3 LP-4 THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE ENTIRE SPECIFICATION AND REVIEW DRAWINGS FOR ALL OTHER TRADES, FOR A COMPLETE ONDERSTANDING OF THIS PROJECTS ELECTRICAL REQUIREMENTS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR TERMINATING ALONG WITH PULLING THE CAT 5 CABLE. IF A PHONE SERVICE IS REQUIRED TO BE PULLED FROM THE L.L. TELEPHONE ROOM TO TERMINATE THEYSTORE NEWCSIDE TOFCTHE THEN)CABLE (4 R 1 1 COINNECTION ) THE E.C. WILL NEED TO TERMINATE THE FAX MACHINE LINE. THE E.C. WILL NEED TO TERMINATE THE CABLE UNDER THE CASHWRAP BY SUPPLYING AND INSTALLING A SURFACE MOUNT UTILITY BOX AND A 4 PORT COVER PLATE. Lll�l #■ UPI 1►P 1. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND SHALL IMMEDIATELY NOTIFY THE OWNER'S PROJECT MANAGER OF ANY DISCREPANCIES. 2. ALL CONDUITS ARE TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. CONDUITS IN EXPOSED CEILING AREAS SHALL EXIT WALLS AS CLOSE TO ROOF/FLOOR STRUCTURAL DECK AS POSSIBLE. 3. ANY EXISTING MATERIALS OR EQUIPMENT NOT TO BE REUSED MUST BE COMPLETELY REMOVED AND DISPOSED OF PROPERLY THROUGH THE LANDLORD'S DESIGNATED AND APPROVED HAULER. NO EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION OF THE LANDLORD. 4. ANY PENETRATIONS THROUGH FIRE RATED WALLS NEED TO BE APPROPRIATELY FIRE STOPPED TO RETAIN THE WALL'S RATING. 5. CONTRACTOR SHALL ENSURE LOADS BETWEEN PHASES ON PANEL BOARDS ARE BALANCED WITHIN 10%. 6. ALL LOW VOLTAGE WIRING IN CEILING PLENUM (INCLUDING TELEPHONE. DATA, ALARM AND TEMP. CONTROL, SPEAKER WIRING, AND ETC.) SHALL BE ILL LISTED TEFLON PLENUM CABLE. OJUNCTION BOX FOR DT TIMER OJUNCTION BOX FOR HIGH SPEED INTERNET AT 92" A.F.F. LP-12 O3 JUNCTION BOX FOR DEMARC EXTENSION AT 92" A.F.F. O4 EMS DATA CONCENTRATOR AT 92" A.F.F. LP-12 O JUNCTION BOX FOR SECURITY .PANEL AT 92" A.F.F. AND 15" CLEAR FROM ADJACENT BOX PP-5 O QUAD RECEPTACLE WITH FOUR DEDICATED OUTLET CIRCUITS FOR MOSAIC POWER SUPPLY MODULE 1,2,3,4. E.C. TO BREAK TAB BETWEEN UPPER/LOWER OUTLET TO ALLOW FOR SEPARATE CIRCUITS. FIELD VERIFY EXACT LOCATION WITH TEAVANA REP. OUNIPLEX RECEPTACLE WITH A DEDICATED OUTLET CIRCUIT FOR PP-4 MOSAIC POWER SUPPLY MODULE 5. FIELD VERIFY EXACT LOCATION WITH TEAVANA REP. ODUPLEX RECEPTACLE FOR SECURITY AT 46" A.F.F. PP-9 CDDEDICATED QUAD RECEPTACLE FOR DATA RACK EQUIPMENT AT 36" A.F.F. 10 DATA OUTLET FOR PRINTER. FIELD VERIFY EXACT LOCATION WITH TEAVANA REP. 11 DUPLEX RECEPTACLE FOR PRINTER. FIELD VERIFY EXACT LOCATION PP-7 WITH TEAVANA REP. PP-7 12 DUPLEX RECEPTACLE FOR SECURITY PANEL AT 92" A.F.F. PP-5 GDQUADPLEX RECEPTACLE FOR SECURITY CAMERA POWER SUPPLIES AT 92" A.F.F. 14 CONVENIENCE DUPLEX RECEPTACLE AT 88" A.F.F. 15 DUPLEX RECEPTACLE FOR MUSIC SYSTEM AT 48" A.F.F. 16 DEDICATED DUPLEX RECEPTACLES FOR WORKSTATION AT 42" A.F.F. 17 PHONE OUTLET AT 42" A.F.F. 18 DUPLEX RECEPTACLE FOR PORTABLE POS CHARGING STATION. FIELD VERIFY EXACT LOCATION WITH TEAVANA REP. 19 QUADPLEX RECEPTACLE PORTABLE POS CHARGING STATION. FIELD VERIFY EXACT LOCATION WITH TEAVANA REP. 20 QUADPLEX CONVENIENCE RECEPTACLE AT 12" A.F.F. ELECTRICAL KEYED NOTES O1 E.C. SHALL INSTALL DISCONNECT SWITCH FOR SIGNAGE CIRCUITS) AS 18 TABLE TOP G.F.C.I. RECEPTACLE POPUP. E.C. TO FIELD VERIFY EXACT REQUIRED BY N.E.C. 600. REFER TO PLANS FOR NUMBER OF CIRCUITS LOCATION WITH TEAVANA REP. AND LOCATION WITH FIXTURE INSTALLER. REQUIRED. E.C. TO MAKE ALL CONNECTIONS TO SIGN. 19 FIELD VERIFY EXACT LOCATION OF LANDLORD TELEPHONE SERVICE STUB —IN OE.C. SHALL FIELD VERIFY EXACT REQUIREMENTS FOR SMOKE/FIRE ALARM AND EXTEND AS REQUIRED FOR CONNECTION TO TENANT TELEPHONE SYSTEM. REUSE ANY EXISTING DETECTION SYSTEM. REPLACE ANY DEFECTIVE EQUIPMENT. ENSURE EXISTING SERVICE WIRE IS CAT5 OR BETTER. IF NOT, DEVICES. IF THERE IS NOT AN EXISTING SYSTEM, E.C. SHALL SUPPLY AND E.C. SHALL PULL NEW CABLE (AND CONDUIT IF REQUIRED) FROM LANDLORD INSTALL ALL NECESSARY EQUIPMENT (SMOKE DETECTORS, AUDIO/VISUAL EQUIPMENT TO TENANT SPACE. SERVICE CABLE SHALL TERMINATE WITH RJ11 ALARMS, FIRE ALARM PANEL, CONDUIT, WIRE, ETC.) FOR A NEW SYSTEM AS JACK 0 BACKBOARD. PROVIDE 3 4 PLYWOOD BACKBOARD FOR MOUNTING K N / MAY BE REQUIRED BY LANDLORD AND/OR LOCAL FIRE MARSHALL. INSTALL OF NEW ELECTRICAL AND TELEPHONE EQUIPMENT. SIZE AND SECURE AS SMOKE DETECTORS IN SUPPLY OR RETURN DUCTWORK AS REQUIRED BY REQUIRED. PROVIDE DEDICATED GROUND DUPLEX RECEPTACLE FOR POWER TO LOCAL AUTHORITY. FIELD VERIFY AND COORDINATE. E.C. TO USE SIMPLEX TELEPHONE EQUIPMENT. GRINNEL FOR THE FIRE ALARM SYSTEM. 20 PANEL "LP". REFER TO PANEL SCHEDULE. O3 6-30R RECEPTACLE MOUNTED HORIZONTALLY AT 48" A.F.F. FOR FETCO HOT "PP". WATER MACHINE. 21 PANEL REFER TO PANEL SCHEDULE. ® ROUTE 1" CONDUIT IN WALL. CONDUIT TO EXTEND 6" ABOVE CLG. AND 22 DISCONNECT. REFER TO ONE —LINE DIAGRAM. STUBUP IN WET BAR. E.C. SHALL RUN IN BASE OF WET BAR TELE./DATA 23 TRANSFORMER. REFER TO ONE —LINE DIAGRAM. LINES (5 CAT 5) FROM T.B.B. TO EQUIPMENT WITH 6' COILED CABLE (4) OUTLETS IN COUNTER WITH THE CABLE NEEDS TO HAVE 2 ENDS. E.C. TO 24 E.C. TO INSTALL NEMA 6-50R RECEPTACLE AT 18" A.F.F. AND A NEMA 6-50P TERMINATE AT WET BAR. PHONE COMPANY TO TERMINATE AT PHONEBOARD. FOR DISHWASHER. FIELD VERIFY EXACT LOCATION. O5 QUADPLEX W/DEDICATED GROUND AND DATA CONNECTION FLUSH MOUNTED IN 25 DUPLEX RECEPTACLE FLUSH MOUNTED VERTICAL IN WALL AT 84" A.F.F. FOR CASH WRAP FOR LABEL PRINTER. FIELD VERIFY EXACT LOCATION AND REFRIGERATOR/FREEZER. MOUNTING HEIGHT. © E.C. TO SUPPLY CONNECTION FOR FUTURE FETCO HOT WATER MACHINE. 26 PROVIDE CONDUIT AND WIRE FOR POWER AND DATA/PHONE. ROUTE (6-30R) RECEPTACLE MOUNTED HORIZONTALLY AT 48" A.F.F. CONDUITS AS SHOWN ON PLAN DOWN WALL OR COLUMN AND BY SAW CUTTING OR CORE DRILLING FLOOR AS REQUIRED BY LANDLORD. PATCH O7 DUPLEX RECEPTACLE FLUSH MOUNTED VERTICAL IN WALL AT 18" A.F.F. FOR FLOOR AS REQUIRED. COORDINATE EXACT CONFIGURATION WITH TENANT REP. AND LOCATION WITH FIXTURE INSTALLER. GENERAL USE. ® DUPLEX RECEPTACLE FLUSH MOUNTED IN CEILING PER N.E.C. 210-62. 27 PROVIDE HOT, UNSWITCHED CONDUCTOR TO EMERGENCY/EXIT LIGHT TO BONE/IVORY IN COLOR. RENDER FIXTURE OPERATIONAL 24HRS A DAY. O9 FIELD VERIFY EXACT LOCATION OF J—BOX FOR ICE MAKER. 28 LIGHT FIXTURE TO BE CONTROLLED BY LOCAL OCCUPANCY SENSOR. E.C. TO CONNECT EMERGENCY BATTERY PACK TO AN UNSWITCHED LEG OF CIRCUIT 10 E.C. TO RUN SPEAKER WIRE FROM SPEAKER LOCATIONS AND ROUTE DOWN FOR 24 HOUR OPERATION. INSIDE WALL TO DATA OUTLET LOCATION FOR CONNECTION OF AMPLIFIER. 29 GENERAL LIGHT FIXTURE TO BE CONTROLLED BY LOCAL OCCUPANCY SENSOR MAKE FINAL CONNECTIONS. AFTER UNOCCUPIED HOURS. 11 E.C. TO FIELD VERIFY AND SUPPLY CONNECTION OF (11) 22" MONITORS FROM 30 J-BOX FOR CONNECTION OF ALION LED 0-10V DIMMABLE LED DRIVER J-BOX BACK TO MOSAIC POWER SUPPLY MODULE #1. (D100-Z-24) FOR POWERING LED TAPE LIGHTING. E.C. TO FIELD VERIFY EXACT LOCATION WITH TENANT REP. AND LOCATION WITH FIXTURE INSTALLER. 12 E.C. TO FIELD VERIFY AND SUPPLY CONNECTION OF (8) 22" MONITORS AND (1) 55" MONITOR FROM J-BOX BACK TO MOSAIC POWER SUPPLY MODULE #2. 31 J-BOX FOR CONNECTION OF ALUMA-PAK ELECTRONIC NEON POWER SUPPLY (SS9350X) FOR POWERING NEON SIGN LIGHTING. E.C. TO FIELD VERIFY 13 E.C. TO FIELD VERIFY AND SUPPLY CONNECTION OF (10) 22" MONITORS FROM EXACT LOCATION WITH TENANT REP. J-BOX BACK TO MOSAIC POWER SUPPLY MODULE #3. 30 J-BOX FOR CONNECTION OF COOLEDGE LED 0-10V DIMMABLE LED DRIVER 14 E.C. TO FIELD VERIFY AND SUPPLY CONNECTION OF (1) 22" MONITORS, (1) (EDRV-030W-UNV-058-010-0606-4-SM) FOR POWERING LED SHEET 46" MONITOR AND (1) 55" MONITOR FROM J-BOX BACK TO MOSAIC POWER LIGHTING. E.C. TO FIELD VERIFY EXACT LOCATION WITH TENANT REP. AND SUPPLY MODULE #4. LOCATION WITH FIXTURE INSTALLER. 15 E.C. TO FIELD VERIFY AND SUPPLY CONNECTION OF (1) 22" MONITORS, (1) 33 LED LIGHTS TO BE POWERED BY LED DRIVERS UNDER TABLE. REFER TO 46" MONITOR AND (2) 55" MONITOR FROM J-BOX BACK TO MOSAIC POWER POWER PLAN FOR LOCATIONS OF J-BOXS AND LED DRIVERS. SUPPLY MODULE #5. 34 DUPLEX RECEPTACLE FLUSH MOUNTED VERTICAL IN CABINET AT 26" A.F.F.. 16 NON -FUSED DISCONNECT SWITCH FOR CONNECTION OF TANK TYPE WATER 35 DUPLEX RECEPTACLE FOR UNDER COUNTER INSTANTANEOUS WATER HEATER. HEATER. FIELD VERIFY EXACT LOCATION. 17 EXISTING RECEPTACLE AND SWITCHED TO REMAIN. RECIRCUIT AS INDICATED. A 2401 Utah Avenue South Seattle, Washington 98134 (206) 318-1575 THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORP. WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THEOTHER (EXCEPTASSTATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. SEP 15 2015 J� �� My of Tukirvila BUILDING DIVISION THIS DRAWING PREPARED UNDER MY SUPERVISION, AND I DISCLAIM ANY RESPONSIBILITY FOR THE EXISTING BUILDING, CONSTRUCTION ELEMENTS, SITE CONDITIONS, OR ANY DOCUMENT WHICH DOES NOT BEAR MY SEAL. 6897 REGIST D ARCHIT c FREDERICK J. GLIA STATE OF WAS GTON Architect: Frederick Goglia ARC VISION, INC. 1950 CRAIG RD. SUITE 300 • ST. LOUIS, MO 63146 Revision Schedule Rev Date By Description 1 ............................................. ...... ..........................� ................ CITY OF TUI<� VI/li' ,A AUG 2 4 20115 PER'Wtr CENTER UJ z 00 W 00 L r U a C LO N = (ID U Lo z ~ Q o cy N N CD0 co cc V .� a V J CL 00 Cl) f— Project #: 150384 Store #: XxUUC-)= Project #: Issue Date: 08/07/15 Design Manager: LISA DOYLE LEED ®AP: N/A Construction Documents: Checked by: Sheet Title: LIGHTING AND POWER PLAN h 6 Scale: As noted Sheet Number: _12 REFER TO SPEC'S FOR TIMECLOCK. COORDINATE TIME SETTINGS WITH OWNER AND LANDLORD. n OVERRIDE TIMER. SEE SWITCH BANK DETAIL - CIRCUIT BRKR DESCRIPTION SIGN —STOREFRONT REC—STOREFRONT SPARE SPARE CIRCUIT BRKR DESCRIPTION LTG —SALES TRACK EM EXIT LTG —STOCK EM EX SPARE SPARE SPARE CIRCUIT BRKR DESCRIPTION LTG -TRACK LTG -SALES LED LTG -SALES NEON SIGNS SPARE SPARE SPARE LP-4 L� I LP-9 1 1►11115011 STOREFRONT CONTACTOR dw _J z H 9 15- U) W U O W I— 0' GENERAL LTG CONTACTOR ELECTRICALLY HELD) TO STOCK OCC. DISPLAY LTG CONTACTOR S * - UNSWITCHED LEG TO FIXTURES REQUIRING 24HR. OPERATION. N.C. = NORMALLY CLOSED N.O. = NORMALLY OPEN TIMECLOCK AND CONTACTOR FOR AUTOMATIC SHUT OFF OF ALL SPACE LIGHTING AS REQUIRED BY ENERGY CODE EXIST. 1-1 /4" 4C 1 V GND EXIST. (MIN) NEW BY E.C. /4 C 13 8, 1 "C 1 8, GND 1 10 GND E.C. TO I EXACT EXIST 200AS r FIELD VERIFY M METER REQUIREMENTS NEW 100AF EXIST. 100A.S. WITH 100A.F. —•- SERVICE FROM LANDLORD 277/48OV, 30, 4W ELEC. DISTRIBUTION EQUIPMENT Z LEASE LINE �1 _NEW 60AS, 45A. F. EXIST 30KVA, 30 TRANSFORMER 480/120/208V PANELBOARD DESIGNATION _ _>AM__ NEW INSTALL X EXIST 120/208 VOLTS PHASE A WIRE, SOLID NEUTRAL 100 AMPERE BUS TOP FED ___ BOTTOM FED X FLUSH MTD SURFACE MTD X LOCATION ___ RELOCATED EXIST ___ _= AMPERE MAIN _ AKER CKT # DESCRIPTION WATTS LOAD TYPE WIRE SIZE BRKR SIZE o a A B C 2088 1500 1560 3712 3532 2756 2756 3900 3900 o a BRKR SIZE WIRE SIZE LOAD TYPE WATTS DESCRIPTION CKT # 1 REC-DATA RACK 360 R 12 20 1 1 15 12 R 1728 REC-ICE MAKER 2 3 REC-PRINTER 1200 R 12 20 1 1 20,12 R 300 REC-IPODS & AMP 4 5 REC-GEN. MANGER DESK 540 R 12 20 1 1 20 12 R 1020 REC-REFRIG/FREEZER 6 7 REC-POS CHARGE STATION 540 R 12 20 1 2 40 8 M 3172 DISHWASHER 8 9 REC-WORKSTATION 360 R 12 20 1 3172 10 11 AHU-1, CU-1 1456 M 12 15 2 1120112 M 1300 INSTANT. WATER HEATER 12 13 15 FETCO WATER MACHINE 1456 1 20 12 M 1300 INSTANT. WATER HEATER 14 1950 M 10 30 2 2 30 10 M 1950 FETCO WATER MACHINE 16 17 1950 1950 18 8556J SUB TOTALS CONNECTED LOAD 25704_ PHASE BALANCE 8.OX L = LTG OR SIGNAGE R = RECEPTACLE M = MISCELLANEOUS H = K = KITCHEN NOTE: ALL BREAKERS SHALL BE BOLT -ON, UNLESS OTHERWISE NOTED. 0 - INDICATES THIS CIRCUIT TO RECIEVE HANDLE LOCK -ON CLIP * REFER TO ONE -LINE DIAGRAM FOR WIRE SIZE TO THIS EQUIPMENT SERVICE D LOAD CONNECTED DEMAND TRANSFORMER FOR LP 16774W 18598W TRANSFORMER FOR PP 25704W 25704W TOTAL 42,478W 44,302W 44,302W = (480 X1.73) - 53.3 AMPS DESIGN ROOF LINE EXISTING 120V, 10, 30A.S., 7A.F. FOR EXISTING FPVAV EXISTING 5.5 F.L.A. RECEPTACLE AND SWITCHED NEW BY E.C. 208V, 10, 30A.S., N.F. LIGHT FOR NEW BY G.C. AHU-1, CU-1 14 M.C.A. NEW BY E.C. NEW BY E.C. 2 #12,, 3/4"C ' 2 #12, 3/4"C 1 12 GND 1 12 GND UNISTRUT CROSS BRACING FOR MOUNTING PANEL TO BE MOUNTED NO TRANSFORMER REFER TO HIGHER THAN 6'7" TO THE ARCHITECTURAL DRAWINGS TOP OF THE HIGHEST FOR ADDITIONAL BREAKER PER N.E.C. 240.24 INFORMATION. NEW BY E.C. NEW 30KVA, 30 PANEL T/ TORK DTS4008 TRANSFORMER TIMECLOCK FOR 480/120/208V LP STOREFRONT REFER TO NEW BY E.C. PANEL RECEPTACLE FOR SCHEDULE TELEPHONE. VERIFY 11 I EXACT LOCATION PANEL II PPII REFER TO I I I PANEL I SCHEDULE C° FLOOR LINE 1 #6 - - NEW BY E.C. GND TO 4 1-1/4"C BLDG STEEL 13, 1 8 GND ELE CTR CAL ONE—LUNE D1Ar%.zM SCALE NONE- 1. ALL WIRE SHALL BE COPPER ONLY, THW, THWN, CL THHW, OR NEC APPROVED EQUAL OR BETTER. ALL E WIRING SHALL BE IN CONDUIT. WIRE AMPACITY BASED CU ON NEC 110-14c AND TABLE 310-16. U) 2. E.C. SHALL FURNISH ALL NEW ELECTRICAL EQUIP. a) (PANELS, TRANSFORMER, CONDUIT, ETC.) AS E REQUIRED, UNLESS NOTED OTHERWISE. It a) ICU 0.... 3. ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMER, LIGHTS, DEVICES, CONDUIT, WIRE, ETC.) NOT BEING USED SHALL BE REMOVED FROM THE SITE. DO NOT ABANDON IN PLACE. 4. E.C. SHALL FIELD VERIFY ALL EXISTING ELECTRICAL EQUIPMENT. ALSO FIELD VERIFY THAT ANY EXISTING ELEC. EQUIPMENT TO BE REUSED IS OF ADEQUATE SIZE AND CONDITION TO MAINTAIN SAFE OPERATION. IF DISCREPANCIES ARISE CONTACT PROJECT REP. PANEL PP DEMAND LOAD CONNECTED DEMAND RECEPTACLES 330OW 3300W EQUIPMENT 9092W 9092W WATER HEATER 1040OW 10400 W HVAC 2912W 2912W TOTAL 251 7 04W 25, 704W 25,704W _ (208 X1.73) 71.4 AMPS DESIGN PANEL LP DEMAND LOAD CONNECTED DEMAND 1 TRACK (6) TRANS. X 24OW PER LOW VOLTAGE TRANSFORMER 1440W 180OW LIGHTING & SIGN 2520W 315OW RECEPTACLES 5743W 5743W MISC 1080W 1080W WATER HEATER 6000W 6000W FPVAV 66OW 660W +25% LARGEST MOTOR 165W TOTAL 16,774W 18,598W 18,598W _ (208 X1.73) 51.7 AMPS DESIGN THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE ENTIRE SPECIFICATION AND REVIEW DRAWINGS FOR ALL OTHER TRADES, FOR A COMPLETE (1NDERSTANDING OF THIS PROJECTS ELECTRICAL REQUIREMENTS. CONTRACTOR'S MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. ANY DISCREPANCIES IN EXISTING CONDITIONS AS SHOWN SHOULD BE BROUGHT TO THE ATTENTION OF TEAVANA CONSTRUCTION DEPARTMENT AND CLARIFIED BEFORE SUBMITTING BIDS. CHANGE ORDERS WILL NOT BE ALLOWED FOR ANY WORK REQUIRED DUE TO EXISTING CONDITIONS NOT BEING FIELD VERIFIED BY CONTRACTOR PRIOR TO SUBMITTING BID. 1. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND SHALL IMMEDIATELY NOTIFY THE OWNER'S PROJECT MANAGER OF ANY DISCREPANCIES. 2. ALL CONDUITS ARE TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. CONDUITS IN EXPOSED CEILING AREAS SHALL EXIT WALLS AS CLOSE TO ROOF/FLOOR STRUCTURAL DECK AS POSSIBLE. 3. ANY EXISTING MATERIALS OR EQUIPMENT NOT TO BE REUSED MUST BE COMPLETELY REMOVED AND DISPOSED OF PROPERLY THROUGH THE LANDLORD'S DESIGNATED AND APPROVED HAULER. NO EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION OF THE LANDLORD. 4. ANY PENETRATIONS THROUGH FIRE RATED WALLS NEED TO BE APPROPRIATELY FIRE STOPPED TO RETAIN THE WALL'S RATING. 5. CONTRACTOR SHALL ENSURE LOADS BETWEEN PHASES ON PANEL BOARDS ARE BALANCED WITHIN 10%. 6. ALL LOW VOLTAGE WIRING IN CEILING PLENUM (INCLUDING TELEPHONE. DATA, ALARM AND TEMP. CONTROL WIRING) SHALL BE ULC LISTED FT6 RATED CABLE. WHEN REUSING EXISTING PANELS, E.C. SHALL VERIFY THE CONDITION AND QUANTITY OF ALL EXISTING CIRCUIT BREAKERS. REPLACE DAMAGED BREAKERS WITH NEW. PROVIDE ANY ADDITIONAL OR BREAKERS OF DIFFERENT AMPERAGE OR POLE AS REQUIRED TO MEET THE END RESULT INDICATED IN THE PANEL SCHEDULE. NEW BREAKERS SHALL BE OF THE SAME MFG AND CHARACTERISTICS OF THE EXISTING. THE SUBMISSION OF THE BID PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED TO THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE SITE. PANELBOARD DESIGNATION RLP' X —_ NEW INSTALL EXIST LOCATION RELOCATED EXIST 120/208_VOLTS A BREAKER PHASE WIRE, SOLID NEUTRAL AMPERE BUS _100_AMPERE MAIN TOP FED ___ BOTTOM FED X FLUSH MTD ___ SURFACE MTD X CKT DESCRIPTION WATTS LOAD WIRE BRKR a A B C J a BRKR WIRE LOAD WATTS DESCRIPTION # TYPE SIZE SIZE 12 20 1 652 12 20 1 1380 12 20 1 868 12 20 1 669 12 20 1 1872 - 20 1 1080 - 20 1 847 - 20 1 838 - 20 1 770 SIZE SIZE TYPE 1 LTG- SALES/TRAC K/EM/EX IT 422 L 1 20 12 R 230 REC-P.O.S. 2 3 SIGN -STOREFRONT 1200 L 1 20 12 R 180 REC-STOREFRONT 4 5 LTG -TRACK 628 L 1 20112 R 240 1 REC-SCALES 6 7 LTG-STOCK/EM/EX 129 L 1 20 12 R 540 REC-GEN. CASH DRY BAR 8 9 LTG -SALES LED NEON SIGNS 912 L 1 20 12 R 960 REC-GENERAL HVAC 10 11 SPARE -- - 1 20 12 M 1080 REC-PH. CLOCK SECURITY 12 13 SPARE -- - 1 20 12 R 847 MOSAIC PW. SUPPLY #1 14 15 SPARE -- - 1 20 12 R 838 MOSAIC PW. SUPPLY #2 16 17 SPARE -- - 1 20 12 R 770 MOSAIC PW. SUPPLY #3 18 19 :::, , :�:::::ii;:::; <::::;<;'ss;£%.., , > " :<.£:.>»«;:£:««:.:::..:..:...::..:....:......::.:,...,....:........:.:.:...:::..:..::..._....,;£££££££;££' +I.I..::..:...,.:::::::.::::::.:.....:..:.::.....:::..,,:::,.::::::::::.::::::::,:..:.:.::..:.:.:..:..:...,,:,,.,..::,.::.:..::...::.::,...:....::::... E::»1.".'.'.£9:.:...... f.`";..`:: /.:,::::»:;,^:<:::.:�..»:::.::�:::::>.;..,,1,:ifn,'i<fiifi/.,£:j:::::::,.iiii:%.:/.' ££�.. � '6801NAl::;::».»,..,.,.,.::...:..<.:::....::..::.:..:...:..:.....<.t.:.,,..:.r,::::::::.:»::......... .....................:,:...................................s................................. ..S.:!law..../� ::.:::..,:.::::..,::»::».,..::..<:.. 458 :,�iw�:21 <....:;<<.: <.:: 1 20 12 R 458 MOSAIC PW. SUPPLY 20 12 R 680 MOSAIC PW. SUPPLY 5 22 23 2 40 8 M 3000 WATER HEATER 24 ,........... 25 ::£ F<B' LIII'II> ` � >:, F 3000 30 00 26 N. -- 27 >' 1 20 — — S ARE 28 29 s'> ... :..,.:%:,:<:.,;:: ,<;<:<.,,:.<..:%, .;;.., - SPARE 30 31 <�. � ;%,:.:.. 20 - SPARE 32 ,::<,...:.. .. 2 12 M 660 FPVAV 35 zsy': "':1,......<;i';'/,£:';;/::i£':'££^.:£%£'l:£%:/£`>;;: %£££::>n: •:: ,.....:::. > K>A. ,,,'i;££££��,r.£:S:£�'ff,::u"`r.:£^;,':::;"�:;'1,i:°r.i:;£>..r..ai!?„1:::...:%£:./:h'nSi;�:: .,.... s£%r i£ »:'/.:..:../£:5':':::::£';'.:'/»:irk:';.'::: PARE 36 37 .......................:..:::..::. 38 39 „. NO N Nal 40 41 ,7.?y: ., Sim J.!y,"i:42 ,. 5626 5430 5718 SUB TOTALS L = LTG OR SIGNAGE R = RECEPTACLE CONNECTED LOAD 16774 M = MISCELLANEOUS H = PHASE BALANCE 5.OX K = KITCHEN NOTE: ALL BREAKERS SHALL BE BOLT -ON, UNLESS OTHERWISE NOTED. 0 - INDICATES THIS CIRCUIT TO RECIEVE HANDLE LOCK -ON CLIP �c - REFER TO ONE -LINE DIAGRAM FOR WIRE SIZE TO THIS EQUIPMENT UGW FiMRE SCHEDULE LAMP SCHEDULE QTY SYMBOL TYPE MANUFACTURER CATALOG NO. DESCRIPTION NOTES VOLTS REC SUR PEN WAL FIXTURE IX TR MANUFACTURER/ LAM/ LAMP/ 11 ® CA JUNO ICIALEDG4-6-1 4" DOWN LIGHT W/WHITE TRIM 1 120 X 1 10.2 11 L.E.D. 440LEDG427K6WH 3 ® E4 LIGHTOLIER MIGN-25-LC-UN RECESSED EMERGENCY WITH 90 4,7 120 X 2 25 50 -- MINUTE LEAD CALCIUM BATTERY -- 73ft L1 AION LED 4024-92-LE 4000 SERIES LED LIGHTING WITH 1 120 X 2 2.8W 126 -- D100-Z-24 0-10V DIMMABLE LED DRIVER /FT -- 3ft L2 COOLEDGE SPPLS600K30U1212 EDRV030WUNV- LED SQ CORNER LIGHTING SHEETS 1 120 X 2 5W 30 05801006064SM 0-10V DIMMABLE LED DRIVER / FTSQ -- 4 o R1A JUNO TLR2WH MINIATURE SINGLE CIRCUIT 24 TRACK 1 12 X NOT APPLICABLE 2 R2A JUNO TLR4WH MINIATURE SINGLE CIRCUIT 48 TRACK 1 12 X NOT APPLICABLE 4 R4A JUNO TLR8WH MINIATURE SINGLE CIRCUIT 96 TRACK 1 12 X NOT APPLICABLE 6 - S1A JUNO TLR38WH LIVE END POWER FEED WHITE FINISH 1 120 X NOT APPLICABLE 4 S2A JUNO TLR50WH CENTER "MINI -CONNECTOR" WHITE FINISH 1 120 X NOT APPLICABLE 6 ® S3A JUNO TL549N-13L 12V REMOTE MOUNT MAGNETIC TRANSFORMER 1 120 X NOT APPLICABLE 27 ® TA JUNO TL252L-3-S-WH TRAC 12" LED 1 12 X 1 13 13 L.E.D. CYLINDRA SPOTLIGHT 30 T1 JUNO TL114G2-3-S-WH TRAC 12" LED 1 12 X 1 6.6 7 L.E.D. MINI -CYLINDER SPOTLIGHT 30 cad T2 JUNO TL114G2-3-F-WH TRAC 12" LED 1 12 X 1 6.6 7 L.E.D. MINI -CYLINDER FLOODLIGHT 2 ® X1A COMPASS CELR2NEG UNIVERSAL EDGE -LIT EXIT SIGN 4.7 120 X -- -- 4 L.E.D. WITH 90MIN. INTERNAL BATTERY 1 ® X2A LITHONIA LHQM-LED-G UNIVERSAL MOUNT L.E.D. EXIT SIGN W/90MIN. INTERNAL BATTERY 4.7 120 X -- -- 5 L.E.D. 1. FIXTURES AND LAMPS SUPPLIED BY TENANT AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. 2. EQUIP NEW FLUORESCENT LIGHT FIXTURES WITH ELECTRONIC BALLASTS. 3. FIXTURES SHOWN WITH CROSS -HATCH ARE TO BE NIGHT LIGHTS WITH EMERGENCY BATTERY BALLAST. RECEIVED CITY OF T.UKWILA 4. FIXTURES USED FOR EXIT, EMERGENCY, OR NIGHT LIGHTING TO BE ON LOCKOUT CIRCUIT. 5. GENERAL CONTRACTOR SHALL CLEAN AND RELAMP EXISTING FIXTURES TO REMAIN TO LIKE -NEW CONDITION. FIELD VERIFY LAMP TYPE. AUG 2 4 2015 6. MOUNT TIGHT AS POSSIBLE TO CEILING. PERMIT CENTER 7. E.C. TO SUPPLY AND INSTALL ALL EXIT SIGNS. E.C. TO INSTALL ALL EMERGENCY LIGHTS. 8. E.C. TO INSTALL 90 MINUTE BATTERY BACKUP EMERGENCY BALLAST MODEL NUMBER 650 ON EMERGENCY FIXTURES. 't 'e, V� a a e 2401 Utah Avenue South Seattle, Washington 98134 (206) 318-1575 THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORP. WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SP ECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION O N R LIABILITY TO THEOTHE C R EX EPT AS STATED ( ABOVE UNTIL A W RITTEN AGREEMENT IS FULLY EXE CUTED BY BOTH PARTIES THIS DRAWING PREPARED UNDER MY SUPERVISION, AND I DISCLAIM ANY RESPONSIBILITY FOR THE EXISTING BUILDING, CONSTRUCTION ELEMENTS, SITE CONDITIONS, OR ANY DOCUMENT WHICH DOES NOT BEAR MY SEAL. 6897 REGIST ED ARCHI E r REDERICK J. G GLIA TATE OF WASHI GTON S -2).):5 Architect: Frederick Goglia ARC VISION, INC. 1950 CRAIG RD. SUITE 300 • ST. LOUIS, MO 63146 Revision Schedule Rev = Date µBv £ Descri C. W z co 00 00 LLJ U Cn c LO 0) N = N U � Q Z Q p .N 0 0 fl . D_ W 0- 0D U) F- Project #: 1150384 Store #: xxxxx_XXX Project #: Issue Date: 08/07/15 Design Manager: LISA DOYLE LEED ®AP: N/A Construction Documents: Checked by: i <; Sheet Title: SCHEDULES Scale: As noted Sheet ber: 1t114 16 - ELECTRICAL 1. GE:NEBAh A. APPLICABLE PROVISIONS OF AIA DOCUMENT A201, "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION", AND DIVISION 1 GENERAL CONDITIONS GOVERN WORK UNDER THIS SECTION AND ALL OTHER SECTIONS OF DIVISION 16. B. APPLICABLE PROVISIONS OF THIS SECTION GOVERN WORK UNDER ALL OTHER SECTIONS OF DIVISION 16. WORK COVERED BY THIS SECTION SHALL CONSIST OF PROVIDING ALL MATERIAL, LABOR, EQUIPMENT AND SERVICES NECESSARY FOR A COMPLETE, TESTED AND ADJUSTABLE ELECTRICAL INSTALLATION READY FOR OPERATION AS SPECIFIED HEREIN AND AS SHOWN ON THE DRAWINGS. C. THE TERM CONTRACTOR AS USED IN THIS SECTION SHALL MEAN ANY CONTRACTOR OR SUBCONTRACTOR WHO HAS CONTRACTED TO PERFORM WORK INCLUDED IN AND DEFINED BY THIS SECTION AND ALL OTHER SECTIONS OF DIVISION 16. 2. CONTRACTOR'S RESPONSIBILITY A. PRIOR TO SUBMITTING HIS BID, CONTRACTOR SHALL CAREFULLY EXAMINE THESE CONSTRUCTION DOCUMENTS, THE DEVELOPER'S EXHIBITS, AND THE SITE, TO INQUIRE FULLY INTO DIFFICULTIES AND COSTS OF WORK, AND TO DETERMINE THE SCOPE AND CHARACTER OF WORK TO BE DONE. CONTRACTOR SHALL INCLUDE ALL NECESSARY COSTS TO LOCATE AND/OR EXTEND ALL UTILITIES INCLUDING LIGHTING PANELS, POWER PANELS, ELECTRICAL SERVICE, PHONE SERVICE AND/OR MODIFY EQUIPMENT TO MEET THE INTENT OF THE CONTRACT DOCUMENTS. THE OWNER, OWNER'S AGENT, ARCHITECT, ENGINEER OR DESIGNER SHALL NOT BE RESPONSIBLE FOR FAILURE OF THE CONTRACTOR TO DETERMINE DIFFICULTIES AND COSTS IN THE PROJECT OR FOR HIS OVERLOOKING OF THE REQUIREMENTS. B. IF THIS CONTRACTOR DOES NOT CLEARLY UNDERSTAND THE PLANS AND SPECIFICATIONS, OR IF THERE ARE ANY REQUIREMENTS WHICH ARE AMBIGUOUS IN THE CONTRACTOR'S OPINION, HE SHOULD CALL THIS TO THE ATTENTION OF THE ARCHITECT PRIOR TO BIDDING, SINCE THIS CONTRACTOR WILL BE HELD RIGIDLY TO THE INTERPRETATIONS OF THE ARCHITECT AND ENGINEER. C. CONTRACTOR SHALL SCHEDULE HIS WORK IN COOPERATION WITH OTHER TRADES INSTALLING INTERRELATED WORK. ALL WORK SHALL BE SCHEDULED TO MAINTAIN SERVICE TO ALL REQUIRED AREAS DURING THE COURSE OF THE CONSTRUCTION EXCEPT FOR SHORT TERM PLANNED SHUTDOWNS, ANY OF WHICH SHALL BE PRE -SCHEDULED WITH THE OWNERS AGENT AND THE LANDLORD. 3. WORKMANSHIP AND GUARANTEE A. IN ENTERING INTO A CONTRACT COVERING THIS WORK, THE CONTRACTOR ACCEPTS THE SPECIFICATIONS, AND GUARANTEES THAT THE WORK WILL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. CONTRACTOR FURTHER GUARANTEES THAT THE WORKMANSHIP AND MATERIAL WILL BE OF THE BEST PROCURABLE AND THAT NONE BUT EXPERIENCED WORKMEN EXPERIENCED IN EACH PARTICULAR CLASS OF WORK WILL BE EMPLOYED. CONTRACTOR FURTHER GUARANTEES TO REPLACE AND MAKE GOOD AT HIS OWN EXPENSE ANY DEFECTS DUE TO FAULTY WORKMANSHIP OR MATERIAL WHICH MAY DEVELOP WITHIN ONE (1) YEAR AFTER FINAL PAYMENT AND ACCEPTANCE BY THE ARCHITECT. 4. CODES AND STANDARDS A. CONTRACTOR WILL COMPLY IN ALL RESPECTS WITH THE ADOPTED BUILDING CODES, APPLICABLE LAWS, ORDINANCES, AND REGULATIONS AS MAY APPLY ACCORDING TO THE RULING OF THE CONTROLLING PUBLIC OFFICIAL SHOULD THE CONTRACTOR PERFORM ANY WORK THAT DOES NOT COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE LAWS, ORDINANCES AND REGULATIONS, OR WHICH DOES NOT RECEIVE THE APPROVAL OF THE CONTROLLING PUBLIC OFFICIAL, HE SHALL BEAR ALL COSTS ARISING IN CORRECTING THE DEFICIENCIES. ALL ELECTRICAL EQUIPMENT SHALL BEAR THE UNDERWRITER'S LABORATORY LABEL. 5. FEES ON PERMITS A. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND MAKING PAYMENT FOR ALL FEES, PERMITS AND INSPECTIONS RELATING TO HIS WORK. 6. CONTRACT DRAWINGS A. THE DRAWINGS SHOW THE GENERAL ARRANGEMENT AND INTENT OF THE DESIGN AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONDITIONS AND THE WORK OF OTHER TRADES WILL PERMIT. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS, AND ACCESSORIES WHICH MAY BE REQUIRED, NOR IS IT IMPLIED THAT ALL CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE SYSTEMS OR BUILDING COMPONENTS HAVE BEEN INDICATED. THE CONTRACTOR SHALL INVESTIGATE ALL EXISTING CONDITIONS AFFECTING THE WORK AND ARRANGE HIS WORK ACCORDINGLY, PROVIDING SUCH FITTINGS, OFFSETS, ACCESSORIES AND DEVICES AS MAY BE REQUIRED. THE DRAWINGS AND SPECIFICATIONS ARE MUTUALLY COMPLEMENTARY, AND ANY WORK REQUIRED BY ONE BUT NOT BY THE OTHER SHALL BE PERFORMED BY BOTH. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL MATERIALS AND SERVICES REQUIRED FOR A COMPLETE AND WORKING PROJECT AT NO ADDITIONAL COST EVEN THOUGH EACH AND EVERY NECESSARY ELEMENT THEREOF IS NOT SPECIFICALLY IDENTIFIED HEREIN EACH AND EVERY NECESSARY ELEMENT THEREOF IS NOT SPECIFICALLY IDENTIFIED HEREIN. B. CONTRACTOR SHALL NOT SCALE FROM THE DRAWINGS BUT SHALL FOLLOW THE ARCHITECTURAL DRAWINGS OR EXISTING BUILDING CONDITIONS WHERE APPLICABLE, IN ESTABLISHING DIMENSIONS AND LINES OF RUN, SINCE DIMENSIONS ON THE FINAL ARCHITECTURAL DRAWINGS OR AT THE SITE MAY NOT COINCIDE WITH THOSE SHOWN ON THE ELECTRICAL DRAWINGS, THE CONTRACTORS SHALL VERIFY WITH THE DIMENSIONED ARCHITECTURAL DRAWINGS OR THE SITE CONDITIONS THE EXACT MATERIAL QUANTITIES AND LENGTHS NECESSARY. C. SIGNIFICANT DEVIATIONS OR CHANGES FROM THE DRAWINGS WHICH ARE REQUIRED TO ACCOMPLISH THE INTENT OF THE CONTRACT DOCUMENTS MUST BE REVIEWED WITH THE ARCHITECT AND APPROVED BEFORE PROCEEDING. 7. SHOP DRAWINGS A. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, FOUR (4) COPIES MINIMUM, FOR ALL MANUFACTURED PRODUCTS. EACH SHOP DRAWING SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO ASSURE THAT ALL DIMENSIONS, QUANTITIES, CONNECTIONS, CAPACITATES AND ACCESSORIES SHOWN ARE IN CONFORMANCE WITH THE CONTRACT DOCUMENTS, AND SHALL BE MARKED OR STAMPED TO CONFIRM THAT SUCH REVIEW WAS MADE AND COMPLIANCE WAS CONFIRMED. B. APPROVAL OF SHOP DRAWINGS BY THE OWNER, OWNER'S AGENT, ARCHITECT, ENGINEER OR DESIGNER, WILL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF COMPLYING WITH ALL TERMS OF THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR PERFORMANCE OF ALL EQUIPMENT PURCHASED, FOR PROPER FIT, AND OTHER DIMENSIONAL REQUIREMENTS. 8. RECORD DRAWINGS A. CONTRACTOR SHALL MAINTAIN AT THE JOB SITE ONE SET OF DOCUMENTS AS "RECORD DRAWINGS" FOR THE PURPOSE OF DAILY MARKING OF ALL SUBSTANTIAL REVISIONS TO THE DOCUMENTS INCLUDING BUT NOT LIMITED TO ELECTRICAL CHANGES, AND LOCATIONS OF UTILITIES, PANELBOARDS, DISCONNECTS, STARTERS AND OTHER DEVICES REQUIRING PERIODIC OPERATIONAL ATTENTION, ADJUSTMENT, OR SERVICE INCLUDING ACCESS THERETO, AT THE COMPLETION OF THE PROJECT, THIS SET SHALL BE RETURNED TO THE ARCHITECT FOR THE PURPOSE OF MAKING FINAL "AS -BUILT DRAWINGS". 9. EQUIPMENT SUBSTITUTION A. SPECIFIC MANUFACTURERS AND MODELS OF EQUIPMENT HAVE BEEN USED IN THE DEVELOPMENT OF THE DRAWINGS AND DESIGNS. THIS CONTRACTOR MUST SUBMIT TO THE OWNER ANY CHANGES AND/OR SUBSTITUTIONS FOR APPROVAL PRIOR TO INSTALLATION OR EXECUTION. ANY CHANGES WHICH DO NOT RECEIVE THE OWNER'S APPROVAL MAY BE SUBJECT TO REMOVAL OR REPLACEMENT AS ORIGINALLY SPECIFIED, AND WILL BE AT THE CONTRACTOR'S EXPENSE. B. IF THIS CONTRACTOR SUBSTITUTES FOR SPECIFIED EQUIPMENT ANY OTHER EQUIPMENT WHICH REQUIRES ANY CHANGES TO THE DESIGN, ALL COST OF REDESIGN AND RECONFIGURATION RESULTING FROM SAID SUBSTITUTION SHALL BE BORNE BY THE SUBMITTING CONTRACTOR. 10. EQUIPMENT INSTALLATION AND SUPPORT A. CONTRACTOR SHALL SUPPORT PLUMB, RIGID AND TRUE -TO -LINE ALL WORK AND EQUIPMENT INSTALLED. THIS CONTRACTOR SHALL DETERMINE HOW EQUIPMENT, FIXTURES, ETC., ARE TO BE SUPPORTED, MOUNTED, OR SUSPENDED AND SHALL PROVIDE ACCESSORIES REQUIRED FOR PROPER SUPPORT WHETHER SHOWN ON THE DRAWINGS OR NOT. IF SUPPORTS ARE REQUIRED, CONTRACTOR SHALL SUBMIT DRAWINGS TO THE ARCHITECT FOR APPROVAL. B. PRODUCTS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS PRINTED INSTALLATION AND MAINTENANCE LITERATURE. COMPONENTS REQUIRING PERIODIC MAINTENANCE OR ADJUSTMENTS SHALL BE LOCATED OR INSTALLED AS TO PERMIT ACCESS WITHOUT DAMAGE TO STRUCTURE, FINISHES OR OTHER EQUIPMENT. C. ALL CONDUIT CONNECTING TO SWITCHGEAR, PANELS, MOTORS, AND OTHER EQUIPMENT SHALL BE INSTALLED WITHOUT STRAIN AT THE CONNECTIONS. THE CONTRACTOR MAY BE REQUIRED, AS DIRECTED, TO DISCONNECT CONDUITS TO DEMONSTRATE THAT THEY HAVE BEEN SO CONNECTED 11. DEMOLMON A. ALL EXISTING EQUIPMENT, NOT INDICATED TO BE INCORPORATED INTO THE NEW SYSTEM SHALL BE DISCONNECTED BY THIS CONTRACTOR FOR REMOVAL BY OTHERS FROM THE JOB SITE. CARE SHALL BE USED SO THAT NO DAMAGE IS DONE TO EXISTING BUILDING, PIPING, DUCTWORK, AND/OR ELECTRICAL EQUIPMENT. ANY DAMAGE ATTRIBUTED TO THIS CONTRACTOR SHALL BE REPAIRED OR REPLACED BY THIS CONTRACTOR. 12. CUTTING AND PATCHING A. ALL CUTTING THAT MAY BE NECESSARY FOR THE INSTALLATION OF THE WORK OR ANY REQUIRED PATCHING THAT RESULTS THEREFROM SHALL BE DONE BY THE PROPER TRADE INVOLVED AND SHALL BE INCLUDED AS PART OF THIS CONTRACT. PATCH TO DUPLICATE UNDISTURBED ADJACENT FINISHES, COLORS, TEXTURES AND PROFILES. COLUMNS, BEAMS, GIRDERS OR JOISTS SHALL NOT BE CUT. B. ALL WORK AFFECTING ROOF OR STRUCTURES SHALL BE PERFORMED BY LANDLORD'S CONTRACTOR AT TENANT'S EXPENSE. 13. CLEANING A. COMPLETION AS IT PERTAINS TO THE CONTRACT COMPLETION DATE IS DEFINED AS THE DAY THE PROJECT IS TURNED OVER TO THE OWNER IN THOROUGHLY CLEAN CONDITION. READY FOR THE OWNER TO TAKE POSSESSION. ALL FIXTURES, MOTORS, EQUIPMENT AND ALL OTHER ELECTRICAL EQUIPMENT FURNISHED OR INSTALLED BY THE CONTRACTOR SHALL BE THOROUGHLY CLEANED. 14. A. PROVIDE THE TESTS AS OUTLINED HEREINAFTER AND OTHER TESTS NECESSARY TO ESTABLISH THE ADEQUACY, QUALITY, SAFETY, COMPLETED STATUS AND SUITABLE OPERATION OF EACH SYSTEM. CORRECT PROMPTLY ANY FAILURE OR DEFECTS REVEALED BY THESE TESTS AND RECONDUCT TEST ON THE CORRECTED ITEMS. B. TEST THE GROUNDS WITH A GROUND RESISTANCE DIRECT READING SINGLE -TEST MEGGER. C. INSULATION RESISTANCE BETWEEN PHASE CONDUCTORS AND GROUND NOT LESS THAN 1,000,000 OHMS. D. THE PANELBOARDS SHALL HAVE PHASE CURRENTS BALANCED TO WITHIN +/- 10% VARIATION BETWEEN AVERAGE PHASE CURRENT AND MEASURED INDIVIDUAL PHASE. E. AN OPERATIONAL TEST OF THE EMERGENCY LIGHTS AND THE EXIT LIGHTS SHALL BE PERFORMED FOR THE OWNER TO DEMONSTRATE CONFORMANCE TO THE SPECIFICATIONS. 15. TEMPORARY ELECTRICAL SERVICE - BY E.C. A. TEMPORARY ELECTRICAL SERVICE SHALL BE IN ACCORDANCE WITH THE BUILDING. CODE. TEMPORARY LIGHTING SHALL BE PROVIDED BY A LAMP LOCATED FOR EVERY 625 SQUARE FEET OF BUILDING AREA WITH A MINIMUM OF ONE PER ROOM. THE LAMP TO BE 100 WATT AND SHALL BE MAINTAINED BY THE GENERAL CONTRACTOR. B. TEMPORARY POWER DISTRIBUTION SHALL BE SUFFICIENT TO ACCOMMODATE THE TEMPORARY LIGHTING AND CONSTRUCTION OPERATIONS, INCLUDING THE USE OF POWER TOOLS (BUT NOT INCLUDING HEAVY-DUTY ELECTRICAL WELDING UNITS), ELECTRICAL HEATING UNITS, AND START-UP OF SPECIFIED BUILDING EQUIPMENT, WHICH IS TO BE TESTED, STARTED OR PLACED INTO OUR USE PRIOR TO COMPLETION OF ITS PERMANENT POWER CONNECTIONS. 16. EXCAVATION AND BACKFILL A. CONTRACTOR SHALL DO ALL EXCAVATION REQUIRED AS SHOWN ON PLANS OR REQUIRED FOR PROPER OPERATION. EXCESS EXCAVATION BELOW THE REQUIRED LEVEL SHALL BE BACKFILLED WITH EARTH AND THOROUGHLY TAMPED. UTILITY SERVICES, SHALL BE INSPECTED AND APPROVED BY THE PROPER INSPECTION AUTHORITY BEFORE BACKFILLING. ELCCTRICAL POWER AND U 1. RELATED DOCUMENTS A. APPLICABLE PROVISIONS OF AIA DOCUMENT A201, "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION", DIVISION 1 GENERAL CONDITIONS AND SECTION 16100 ELECTRICAL SPECIAL CONDITIONS GOVERN WORK UNDER THIS SECTION. B. REFER TO SECTION 16100 ELECTRICAL SPECIAL CONDITIONS REGARDING REGULATIONS AND REQUIREMENTS AFFECTING ALL WORK DESCRIBED IN THIS SECTION. 2. POWER SERVICE - REFER TO ONE -LINE DIAGRAM. A. POWER SERVICE FOR THIS PROJECT SHALL BE PROVIDED FROM THE EXISTING MALL DISTRIBUTION SYSTEM. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MALL MANAGEMENT TO INSURE THAT ALL WORK AND MATERIALS ARE IN CONFORMANCE WITH THE LANDLORD'S STANDARDS. 3. NAM IEPI ATFS A. ELECTRICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO, PANELBOARDS, DISCONNECTS TRANSFORMERS, CONTROLS, ETC., SHALL BE IDENTIFIED WITH THREE PLY LAMINATED PLASTIC. THE OUTSIDE LAMINATIONS SHALL BE BLACK. ENGRAVING SHALL EXTEND THROUGH THE FRONT LAMINATION SO THAT THE BLACK LETTERS APPEAR ON A WHITE BACKGROUND. NAMEPLATES SHALL BE PERMANENTLY ATTACHED WITH SCREWS. B. CIRCUIT DIRECTORY SHALL BE TYPEWRITTEN (HANDWRITTEN IS NOT ACCEPTABLE) AND SHALL IDENTIFY CIRCUIT AS TO TYPE AND LOCATION AS FOLLOWS: "LTG" - FOR LIGHTING CIRCUIT FOLLOWED BY AREA IN WHICH CIRCUIT APPEARS, I.E., "STOCKROOM", "CASH WRAP", ETC. "RECEPT" - FOR RECEPTACLE CIRCUIT FOLLOWED BY AREA IN WHICH RECEPTACLE APPEARS, "STOREFRONT", "CASH REGISTER", ETC. "MOTOR" - FOR MOTOR FOLLOWED BY THE EQUIPMENT IDENTIFICATION AND AREA IN WHICH MOTOR IS LOCATED, I.E. "EXH FAN TOILET", "AHU-ROOF", ETC. 4. CONDUQ A. ALL WIRING SHALL BE RUN IN CONDUIT. THIN WALL EMT CONDUIT SHALL BE FOR SIZES 1/2" THROUGH 2-1/2". ALL CONDUITS LARGER THAN 2-1/2" SHALL BE HEAVYWALL. CONDUITS INSTALLED UNDERGROUND OR IN CONCRETE SLABS SHALL BE PVC JACKETED FLEXIBLE STEEL CONDUIT (SEALTITE) SHALL BE USED IN WET AREAS AND ON ALL MOTORIZED EQUIPMENT. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS, AT A MAXIMUM LENGTH OF 6 FEET. NO BX, ROMEX, ARMORED CABLE, ETC. SHALL BE ALLOWED. B. ALL OPENINGS IN FIRE AND SMOKE WALLS, PARTITIONS, FLOORS AND OTHER SIMILAR PENETRATIONS FOR ELECTRICAL CONDUITS, CABLE OR EQUIPMENT, WHETHER CUT OR IN PLACE, SHALL BE CLOSED WITH A UL APPROVED FIRE RESISTANT SILICONE FOAM SEALANT TO MAINTAIN THE FULL RATING AND INTEGRITY OF THE PARTITIONS, WALLS OR FLOOR. C. CONDUIT BENDS FOR POWER AND LIGHTING CIRCUITS SHALL NOT BE LESS THAN STANDARD RADIUS BENDS. CONDUIT BENDS FOR FEEDERS, TELEPHONE AND COMMUNICATION CIRCUITS SHALL NOT BE LESS THAN LONG RADIUS BENDS. D. O.Z. TYPE DX, TX, OR AX CONDUIT EXPANSION DEFLECTION FITTINGS ARE REQUIRED IN ALL CONDUIT RUNS WHERE MOVEMENT MAY BE ENCOUNTERED. ALL EMT COUPLINGS SHALL BE COMPRESSION TYPE. E. EXPOSED CONDUIT SHALL BE SECURELY SUPPORTED IN PLACE PER CODE BUT ON A MAXIMUM OF 10 FOOT INTERVALS, WITHIN THREE FEET OF EACH BEND, AT EVERY OUTLET OR JUNCTION BOX AND AT THE END OF EACH STRAIGHT RUN TERMINATING AT A BOX OR CABINET. CONDUIT SHALL NOT BE SUPPORTED FROM DUCTWORK OR PIPE WORK. CONDUITS SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO THE BUILDING LINES. GENERALLY, CONDUIT SHALL BE RUN IN CONTACT WITH STRUCTURAL PARTS OF THE BUILDING SO AS TO AVOID SUSPENDED LENGTHS OF CONDUIT. CONDUIT SHALL BE INSTALLED AS TO BE ACCESSIBLE FOR REPLACEMENT AND MAINTENANCE AND GENERALLY CONDUIT SHALL BE INSTALLED TO PERMIT DRAINAGE. 5. WIRE AND CABLE (COPPER ONLY) A. ALL WIRE AND CABLE SHALL BE RUN IN CONDUIT. ALL WIRE AND CABLE FEEDERS AND BRANCH CIRCUITS SHALL CONFORM TO THE LATEST REQUIREMENTS OF THE CURRENT EDITION OF THE N.E.C. AND SHALL MEET ALL ASTM SPECIFICATIONS. WIRE AND CABLE SHALL BE NEW, SHALL HAVE SIZE, GRADE OF INSULATION VOLTAGE AND MANUFACTURER'S NAME PERMANENTLY MARKED ON OUTER COVERING AT REGULAR INTERVAL AND SHALL BE DELIVERED IN COMPLETE COILS OR REELS WITH IDENTIFYING SIZE AND INSULATION TAGS. B. THE ELECTRICAL CONTRACTOR SHALL CALCULATE VOLTAGE DROP ON CONDUCTORS WITH LENGTHS GREATER THAN 75 FEET FROM THE PANELBOARD AND PROPERLY SIZE THE CONDUCTORS PER N.E.C. C. POWER CONDUCTORS: NO WIRE LESS THAN NO. 12 SHALL BE USED EXCEPT FOR CONTROL CIRCUITS OR LOW VOLTAGE WIRING. WIRE SIZES NO. 12 TO NO. 10 SHALL BE SOLID EXCEPT WHERE OTHERWISE INDICATED. WIRE SIZES NO. 8 AND LARGER SHALL BE STRANDED. ALL WIRE SIZES SHOWN ARE AMERICAN WIRE GAUGE SIZES. SIZES NO. 12 AWG THROUGH NO. 8 AWG SHALL BE "THHN." SIZE 4 AWG AND LARGER SHALL BE "THW." D. CONTINUITY: ALL WIRES SHALL BE CONTINUOUS FROM OUTLET TO OUTLET. E. ACCEPTABLE MANUFACTURERS: CABLE AND WIRE SHALL BE STANDARD TYPE AS MANUFACTURED BY GENERAL CABLE COMPANY, CAROL, ANACONDA, ROM OR ITT ROYAL. F. E.C. TO PROVIDE & INSTALL CAT 5 CABLE TO FAX MACHINE & CASHWRAP LOCATION CABLE TO TERMINATE AT PHONE PANEL BOARD LOCATION IN STOCKROOM. 6. COLOR CODING A. A COLOR CQDING SYSTEM AS LISTED BELOW SHALL BE FOLLOWED THROUGHOUT FOR FEEDERS AND BRANCH CIRCUITS AND USED AS A BASIS FOR BALANCING LOAD. --120/208V: PHASE A --BLACK, PHASE B--RED, PHASE C--BLUE, NEUTRAL --WHITE, GROUND--GREEN --277/48OV: PHASE A --BROWN, PHASE B--ORANGE, PHASE C--YELLOW, NEUTRAL --GRAY, GROUND --GREEN 7. BOXES AND FITTINGS A. ALL OUTLETS SHALL BE PROVIDED WITH GALVANIZED OR SHERARDIZED BOXES SUITABLE IN DESIGN TO THE SPACE THEY OCCUPY AND THE PURPOSE THEY SERVE. WALL MOUNTED OUTLET BOXES, EXCEPT FOR 2" PARTITIONS SHALL BE AT LEAST 1 1 /2" DEEP AND/OR DEEPER IF REQUIRED BY THE DEVICE THEY HOLD OR THE NATIONAL ELECTRICAL CODE. B. ALL PULLBOXES SHALL BE MADE OF GALVANIZED STEEL, OF METAL GAUGE AND PHYSICAL SIZE AS REQUIRED BY THE NEC FOR THE NUMBER AND SIZE OF RACEWAYS AND CONDUCTORS INVOLVED. C. FIXTURE OUTLET BOXES IN OR ON CEILINGS SHALL NOT BE LESS THAN 1-1/2" DEEP OR LESS THAN 4" SQUARE. ALL OUTLET BOXES INTENDED TO SUPPORT FIXTURES SHALL BE EQUIPPED WITH 3/8" FIXTURE STUDS FASTENED THROUGH THE BOTTOM OF THE BOX WITH FOUR BOLTS. 8. CIRCUIT BREAKER PANELBOARDS A. PANELS SHALL BE DEAD FRONT, SAFETY TYPE, FURNISHED WITH BRANCH CIRCUIT PROTECTING DEVICES, EQUIPMENT GROUNDING BOX, MAIN BUS AND CABLE LUGS FACTORY ASSEMBLED, WITH ALL COMPONENTS IN PLACE, READY FOR INSTALLATION. PROVIDE 20% SPARE BREAKER CAPACITY AND 25% EXCESS AMPACITY IN EACH PANEL. B. CURRENT CARRYING CONTACT SURFACES SHALL BE SILVER OR TIN PLATED. THE CIRCUIT BREAKERS SHALL BE OF THE MOLDED CASE, BOLT -ON TYPE SUITABLE FOR VOLTAGE AND AMPERE RATINGS INDICATED ON DRAWINGS AND IN SCHEDULES AND SHALL HAVE A MINIMUM INTERRUPTING CAPACITY OF 10,000 AMPERES FOR 120/208V AND 14,000 AMPERES AT 277/48OV. C. MAIN BUSES AND CONNECTORS SHALL BE HARD DRAWN COPPER OF 98% CONDUCTIVITY, WITH CURRENT CARRYING CAPACITY TO MAINTAIN ESTABLISHED RISE TESTS AS DEFINED IN UL STANDARD UL 67. D. CABINET SIZES ARE BASED UPON A 20" WIDE BY 6" DEEP PANEL UNLESS OTHERWISE NOTED. PANELBOARDS SHALL BE EQUIPPED WITH FLUSH TYPE LOCK AND CATCH. ALL LOCKS SHALL BE KEYED ALIKE, AND TWO KEYS ARE TO BE SUPPLIED WITH EACH LOCK. E. PANELBOARDS TO BE BY SQUARE D CORPORATION, GENERAL ELECTRIC, OR WESTINGHOUSE. A. DRY -TYPE TRANSFORMERS SHALL BE OF THE ENCLOSED VENTILATED TYPE WITH KVA AND VOLTAGE RATING AS CALLED FOR ON THE DRAWINGS AND WITH 150' CLASS H INSULATION AND MINIMUM OF SIX STANDARD FULL CAPACITY TAPS. SOUND LEVEL SHALL BE LOW AND INSTALLATION SHALL INCLUDE KORFUND OR EQUAL VIBRATION DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY. (MOUNT TRANSFORMER ON VIBRATION ISOLATORS). LOCATE TRANSFORMER AS NOT TO CAUSE SERVICING OR CLEARANCE DIFFICULTIES OF VIOLATIONS WITH OTHER EQUIPMENT. B. COMPARABLE EQUIPMENT AS MANUFACTURED BY SQUARE D CORPORATION OR GENERAL ELECTRIC 10. TOGGLE SWITCHES A. TOGGLE SWITCHES SHALL BE WHITE AND SHALL BE RATED 20 AMPERES 120/277 VOLT AC TYPE AS MANUFACTURED BY HUBBELL AND SHALL BE AS FOLLOWS: SINGLE POLE--1221--1 THREE WAY--1223--1 B. TOGGLE SWITCHES SHALL BE MOUNTED 4'-0" ABOVE FINISHED FLOOR TO MOUNTING PLATE AND, AT DOORS, INSTALLED ADJACENT TO THE TRIM ON THE STRIKING SIDE OF THE DOOR, REGARDLESS OF THE LOCATION INDICATED ON THE DRAWINGS; THEREFORE, CHECK ALL DOOR SWINGS BEFORE INSTALLATION OF CONDUIT OUTLETS. C. COMPARABLE EQUIPMENT AS MANUFACTURED BY SLATER, LEVITON, AND BRYANT WILL BE ACCEPTABLE. 11. RECEPTACLES A. RECEPTACLES SHALL BE WHITE. UNLESS OTHERWISE NOTED AS MANUFACTURED BY HUBBELL AND SHALL BE AS FOLLOWS: DUPLEX RECEPTACLE--20A-120 VOLT 5362 B. RECEPTACLES SHALL BE MOUNTED 15" ABOVE THE FINISHED FLOOR UNLESS OTHERWISE NOTED. C. COMPARABLE EQUIPMENT AS MANUFACTURED BY SIERRA ELECTRIC CORPORATION, SLATER, BRYANT AND LEVITON WILL BE ACCEPTABLE. 12. DEVISE PLATES A. DEVICE PLATES SHALL BE WHITE UNLESS OTHERWISE NOTED. COMPARABLE EQUIPMENT AS MANUFACTURED BY SIERRA ELECTRIC CORPORATION, HARVEY HUBBELL INC., BRYANT AND LEVITON WILL BE ACCEPTABLE. PAINT MATCH ADJACENT FINISH COLOR. 13. DISCONNECT SWITCHES A. FURNISH AND INSTALL DISCONNECT SWITCHES AS REQUIRED BY CODE. DISCONNECT SWITCHES SHALL BE NEMA HEAVY DUTY TYPE AND UNDERWRITERS LABORATORIES LISTED, MANUFACTURED BY SQUARE D CORPORATION, ITE, GENERAL ELECTRIC, OR WESTINGHOUSE. 14. GROUNDING A. CONTRACTOR SHALL INSTALL A SYSTEM GROUNDING SYSTEM AND AN EQUIPMENT GROUNDING SYSTEM AND SHALL USE ONLY APPROVED GROUNDING CLAMPS AND CONNECTORS AS MANUFACTURED BY PENN-UNION, BURNDY, OR 0-Z MFG. COMPANY. B. THE SYSTEM GROUNDING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND THE UTILITY COMPANY REGULATIONS. CONTRACTOR SHALL CONNECT THE GROUNDING ELECTRODE CONDUCTORS TO THE NEUTRAL BAR INSIDE THE MAIN PANEL. WHEN TRANSFORMERS ARE USED TO PROVIDE A SEPARATELY DERIVED SYSTEM, THE CONTRACTOR SHALL CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE NEUTRAL BAR INSIDE THE SECONDARY SYSTEM PANEL OR SERVICE RATED DISCONNECT SWITCH, DO NOT CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE NEUTRAL LUG INSIDE THE TRANSFORMER. C. THE EQUIPMENT GROUNDING SYSTEM SHALL CONSIST OF A CONTINUOUS CONDUIT INSTALLATION AND A GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR. THIS GROUNDING CONDUCTOR SHALL BE INSTALLED IN EVERY CONDUIT OR RACEWAY WITH THE FEEDER OR BRANCH CIRCUIT CONDUCTORS. THIS GROUNDING SHALL BE EXTENDED FROM THE HOUSING OF EVERY ELECTRICAL LOAD, THROUGH PANELBOARD STATIC GROUNDING BUSSES, TO THE STATIC GROUNDING BUS IN THE MAIN PANEL. THE GROUNDING BUS SHALL BE BONDED TO THE GROUNDING NEUTRAL BAR INSIDE THE MAIN PANEL. 15. LIGHTING FIXTURES A. ALL LIGHTING FIXTURES AND LAMPS SHALL BE FURNISHED BY OWNER, UNLESS NOTED OTHERWISE. THIS CONTRACTOR SHALL INSTALL LIGHTING FIXTURES AND LAMPS AS INDICATED ON THE DRAWINGS AND AS SPECIFIED BELOW, COMPLETE WITH HANGERS, PLASTER FRAMES AND ALL OTHER NECESSARY ACCESSORIES. B. ALL BALLAST, STARTERS AND LAMPHOLDERS IN FLUORESCENT LIGHTING EQUIPMENT ARE TO BE ELECTRICAL TESTING LABORATORIES, UNDERWRITERS LABORATORIES AND CERTIFIED BALLAST MANUFACTURERS APPROVED. ALL BALLAST FOR FLUORESCENT FIXTURES SHALL BE OF THE HIGH POWER FACTOR TYPE AND SHALL BE GENERAL ELECTRIC "MAXI -MISER II" OR ADVANCED MARK III. WHERE OCTRON LAMPS ARE SPECIFIED PROVIDE APPROPRIATE BALLASTS. C. THIS CONTRACTOR SHALL VERIFY THE FINAL CEILING AND FINISH SCHEDULES TO INSURE THE PROPER INSTALLATION AND MOUNTING OF FIXTURES AND SHALL COORDINATE BEFORE MAKING SUBMITTALS. 16. TIMECLOCKS f CONTACTORS A. TIMECLOCKS SHALL BE CALIFORNIA ENERGY COMMISSION APPROVED TORK DIGITAL DTS400B 4 CHANNEL WITHOUT ASTRONOMIC APPLICATIONS OR EQUAL IN ALL STATES. B. LIGHTING CONTACTORS SHALL BE SQUARE D "TYPE L" C. OPERATING HOURS SHALL BE SET AS FOLLOWS: 1. FOR STRIP CENTERS: SET INTERIOR TIMECLOCKS TO 7:OOAM TO 11:OOPM AND STOREFRONT EXTERIOR SIGNAGE TO 5:OOPM TO 11:OOPM 2. FOR MALLS: SET ALL TIMERS TO 8:OOAM TO 11:OOPM. COORDINATE WITH MALL REQUIREMENTS 17. TELEPHONE SERVICE A. THIS CONTRACTOR SHALL INSTALL A TELEPHONE SERVICE CONDUIT AS SHOWN ON THE DRAWINGS AND FURNISH AND INSTALL (1) 2' X 2' X 3/4" PLYWOOD PANEL MOUNTED ON THE WALL AT LOCATION SHOWN ON PLANS. CONTRACTOR SHALL ALSO FURNISH AND INSTALL CAT 5 CABLE END OF DIVISION 16 THE CONTRACTOR FOR THIS WORK IS SPECIFICATION AND REVIEW DRAWINGS A COMPLETE (1NDERSTANDING OF THIS RECEIVED (CITY OF 'TUKWILA AuU 2 ►+ 2b1 PERMIT CENUR 2401 Utah Avenue South Seattle, Washington 98134 (206) 318-1575 THESE DRAWINGS AND SPECIFICATIONS ARE CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORP. WHICH IS THE OWNER OF THE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN PART), SHARED WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF STARBUCKS CORPORATION. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FORA PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THEOTHER (EXCEPTASSTATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. REVIEWED FOR CODE COMPLIANCE- SEP 15 2915 City of Tulvwiia BUILDING DIVISIO'I THIS DRAWING PREPARED UNDER MY SUPERVISION, AND I DISCLAIM ANY RESPONSIBILITY FOR THE EXISTING BUILDING, CONSTRUCTION ELEMENTS, SITE CONDITIONS, OR ANY DOCUMENT WHICH DOES NOT BEAR MY SEAL. 6891 1 REGISTEItD ARCHITE Tn E17ERICK J. GO LIA S AT OF WAS TON < a I - I, Architect: Frederick Goglia ARC VISION, INC. 1950 CRAIG RD. SUITE 300 • ST. LOUIS, MO 63146 Revision Schedule Rev I Date By ' Description s..................... .................... ..................... ..................... ................... ......... ......... I LL W z CU 00 00 W L T_ Uoo LO Q Z Q 0 U U U) V .(tI 'Se o Q o Lo p. S d w IL 00 fn I - Project #: :150384 Store #: XXXXX-)= Project #: Issue Date: 08/07/15 Design Manager: LISA DOYLE LEED ®AP: N/A Construction Documents: ;:4r Checked by: T J Sheet Title: ELECTRICAL SPECIFICATIONS Scale: As noted