Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL15-0767 - RED ROBIN - ELECTRICAL FOR BAR RELOCATION AND LIGHTING
RED ROBIN GOURMET BURGERS 17300 SOUTHCENTER PKWY EXPIRED 1012 6116 EL15-0767 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 2623049110 Permit Number: EL15-0767 Address: 17300 SOUTHCENTER PKWY Issue Date: 11/2/2015 Permit Expires On: 4/30/2016 Project Name: RED ROBIN GOURMET BURGERS Owner: Name: KIR TUKWILA 050 LLC Address: 3333 NEW HYDE PARK RD #100 PO C/O KIMCO REALTY CORP, NEW HYDE PK, SC, 11042 Contact Person: Name: D AARON WELLS Phone: (864) 232-8200 Address: 211 E BROAD ST, GREENVILLE, SC, 29601 Contractor: Name: DENNIS WEBB ELECTRIC INC Phone: (206) 321-8494 Address: 4530 CROWN LN , MALAGA, WA, 98828 License No: DENNIWE031C4 Expiration Date: 2/24/2017 Lender: Name: Address: DESCRIPTION OF WORK: TENANT IMPROVEMENT: RELOCATE ELECTRICAL FOR BAR RELOCATION. INSTALL NEW LIGHTING IN DINING ROOM Valuation of single family: $0.00 Fees Collected: $1,089.66 Valuation of mf/comm: $42,000.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE,TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: �4 Date: �� v I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date:. 5� Print Name: r 54A, This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. S: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA a Community Development Department • Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwi]aWA.gov Electrical Permit No. � � � - 0� IU 7 Project No. Date Application Accepted: Date Application Expires: For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION I King Co Assessor's Tax No.: 2623049110 Site Address: 17300 Southcenter Parkway Suite Number: Floor: Tenant Name: Red Robin Gourmet Burgers New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: Kimco Realty Corp Address: 3333 New Hyde Park Rd. #100 City: New Hyde Park State: NY Zip: 11042 CONTACT PERSON — person receiving all project communication Name: Address: f , rA STt t 'all City: State: /' Zip: f P J Phone, ' Email: Valuation of Project (contractor's bid price): $� !/� ELECTRICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Will service be altered? ❑ Yes Type of Use: )Rr No Adding more than SO amps? ❑ Yes CE!fNo Type of work: ❑ New ❑ Addition ❑ Service Change Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: XPuget Sound Energy ❑ Seattle City Light H."pplicatiom\Fon Applieations On Line\2014 ApplicationsTlectrical Permit Application Revised 1.1-14.dom Revised: January 2014 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals....................................................................$80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Dante: Print Name: L�f Day Telephone: Mailing Address: �d�% balwdiAll ll"- tj'�- City state Zip H:1Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page 2 of 2 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $880.11 EL15-0767 Address: 17300 SOUTHCENTER PKWY Apn: 2623049110 $880.11 ELECTRICAL $838.20 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $838.20 TECHNOLOGY FEE $41.91 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL$880.11 $41.91 Date Paid: Monday, November 02, 2015 Paid By: GEORGE JOHANSON Pay Method: CREDIT CARD 09552G Printed: Monday, November 02, 2015 3:38 PM 1 of 1 7' I���,' WSY57EM5 DESCRIPTIONS PermitTRAK PAID $2,180.49 D15-0228 Address: 17300 SOUTHCENTER PKWY Apn: 2623049110 $1,921.79 DEVELOPMENT $1,921.79 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,921.79 EL15-0767 Address: 17300 SOUTHCENTER PKWY Apn: 2623049110 $209.55 ELECTRICAL $209.55 PLAN CHECK FEE R000.345.832.00.00 0.00 $209.55 PG15-0102 Address: 17300 SOUTHCENTER PKWY Apn: 2623049110 $49.15 PLUMBING $49.15 PLAN CHECK FEE R000.322.103.00.00 0.00 TOTAL FEES PAID BY RECEIPT: R6063 $49.15 $2,180.49 Date Paid: Tuesday, September 01, 2015 Paid By: ALAN RICHARDSON Pay Method: CREDIT CARD 06615G Printed: Tuesday, September 01, 2015 3:46 PM 1 of 1 4cff w'srsrEMs INSPECTION RECORD � Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 .111 Project: —Wo) � Kb Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: a. p.m. Requester: . Phone No: 12-1 ;❑Approved per applicable codes. EI Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD �. Retain a copy with permit INSPECTION NO. PER1V'iIT NO. CITY OF TUKWILA BUILDING DIVISION 4 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � Type of Inspectio Address: /2�00 Date Called: Special Instructions: Date Wanted: ! a. M. Requester: Phone No: �o Approved per applicable codes. LJ Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit �✓�I'�� ` INSPE ON NO. PERMIT 0. CITY OF TUKWILA DUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project: ?k;W(Al . Type of Inspection: i< IA",.+ Address: Date Called: Special In tructions: Date Wanted: a.m M. Requester: n_ 24 Phone No: 24 Y 706 Approved per applicable codes. 11 Corrections required prior to approval. u paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORDf/� v Retain a copy with p ermit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Q�r' Type of Inspection Address: Date Called: Special Instructions: Date Wanted: r I a. l ! pm. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: AA ® o�A CJ � � �®•JET"©� WAr6 To 5-0 , nspector: a_ Date: REINS PECTION' FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit&�— INSPECTION N0. � PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Ins ection Request Line (206) 438-9350 /11 Project: Type of Inspection: . Address: Date Called: Special Instructions: Date Wanted: / / a.m p.m. Requester: &4M,b Phone No: Approved per applicable codes. M Corrections required prior to approval. COMMENTS: t-t '0 GMNI PU t) (To f A10, "r k ! Ji �� t•v ® L (— ZL Inspector: Date:D/ / I I REIN5PECTIUN FEE REQUIRED. Prior to next inspection, tee must be l-1 paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. J INSPECTION RECORD 1 Retain a copy with permit i INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: P ( Type of Inspection: `l Address: /3oC7�.C. P. l Date Called: Special Instructions: Date Wanted: a /. Z P.M. Requester: Phone No: ❑ Approved per applicable codes. Ia, Corrections required prior to approval. COMMENTS: A1e q� (--,or kc�Qi ta-jif5 2 , 2- P612,- F:�3 o t 664— 7 ©iJ . A--T- LLc-i� 1 ,1 Fo 2. rqco - Ir--U to J Cot-A-E Ai\IO s 6C— Lao. �ot� 6�' C k(Q-i (U Jp6rc,- tj (,55 (Ar (4d©. 6L F. �- LA! ( Lf 5 (-'0 C D V L P ro A,; —To d6l Lro 11 44) Inspector: 'Z3 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.� City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 9/2/2016 D AARON WELLS 211 E BROAD ST GREENVILLE, SC 29601 RE: Permit No. EL15-0767 RED ROBIN GOURMET BURGERS 17300 SOUTHCENTER PKWY Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/26/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. Q" 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/26/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley Permit Technician File No: EL15-0767 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 9 Phone 206-431-3670 • Fax 206-431-3665 PERMIT COOR® COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0767 DATE: 09/01/15 PROJECT NAME: RED ROBIN GOURMET BURGERS SITE ADDRESS: 17300 SOUTHCENTER PKWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 09/03/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/01/15 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 2012 Washington State Enery, .;ode Compliance Forms for Commercial, Group, .., and > 3 story R2 and R3 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 2013 Project Info Project Address Red Robin Date 6/22/2015 17300 soutbcenter Pkwy. For Building Department Use Tukwila, WA 98188 Applicant Name: Applicant Address: Applicant Phone: Project Description Q New Building Q Addition 0 Alteration 0 Plans Included Lighting Compliance 0 Lighting Power Density Calculations Q Total Building Performance Path (If Total Building Performance then only LGT-CHK is required.) Interior Lighting Compliance Option Q Building Area Method 40 Space -by -space Met (�oMP1 I A ��'!► 4i L. M w Interior Lighting System Description Briefly describe lighting system type and features. FILIS SEP 18 2015 ty 6 .TI(WIt BUILDING DIVI Additions and Change of Space Use (C101.4.3 & C101.4.4) Addition area or Change of Space Use area complies with all applicable provisions as stand alone project ® Addition area or Change of Space Use area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use scope. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) Q 60% or more of luminaires in space replaced Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing) lighting wattage of project scope Q Less than 60% of luminaires in space replaced Provide Space -by -space Method (L TG-INT-SPA CE) Compliance Form. Document existing total wattage in space and proposed (including existing) lighting wattage of project scope 0 Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased Q New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 Q New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. Q Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. 0 No changes are being made to the interior lighting and space use not changed. ELIS,4-.- 0 7 67 R ITH ION D CITY OF TUKWILA SEP 0 12015 PERMIT CENTER Project Info Project Address Red Robin Date 6/22/2015 17300 Southcenter Pkwy. For Building Department Use Tukwila, WA 98188 Applicant Name: Maximum Allowed Lighting Wattage Location (plan #, room #, or ALL) Space Type" Allowed Watts per f Gros Interior Area in ff Waus Alloweo (watts/fly x area) Dining Dining area: Bar/lounge/leisure dining 1.31 5846 7658 Atrium— Enter Height: Retail Display Allowance from LGT-INT-DISPLAY Select Table C405.5.2(2) category from drop down menu. " For atriums, indicate height.Allowed wettage for first 40 feet is 0.03 Witt. ht., above 40 feet is 0.02 WAt. ht. Proposed Lighting Wattage Area Allowed Watts Total 5846 7658 Location (plan #, room #, or ALL) Fixture Description (Include exempt equipment per Note 3) Number of Fixtures Watts/ Fixture Watts Proposed Dining (CL4), 4A Current Limiter, Serves circuit P4-28 1 480 480 Dining (CL9), 9A Current Limiter, Serves circuit P4-30 1 1080 1080 Dining (CLS), SA current Limiter, Serves circuit P4-32 1 C00 C00 Dining (CL5), 5A Current Limiter, Serves circuit P4-34 1 600 600 Dining (CL6), 6A Current Limiter, Serves circuit P4-36 1 720 720 Dining (CL6), 6A Current Limiter, Serves circuit P4-31 1 720 720 Dining (CLS), 8A Current Limiter, Serves circuit P4-33 1 960 960 Dining (CL9), 9A Current Limiter, Serves circuit P4-35 1 1080 1080 Dining (CL2), 2A Current Limiter, Serves circuit P4-2 1 240 240 Dining (CL2), 2A Current Limiter, Serves circuit P4-4 1 240 240 2012 Waehinatnn State Fnert,. —nde Cmmnliance Forms for Cnmmercial_ Gmun . _ . _ and > 3 etory R2 and R3 Retail Display Lighting from LOT-INP-DISPLAY r �.�:,: Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watt 6 7 2 0 Notes: 1. Forproposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. Forproposed Watts/Fixture, use manufacturer's listed maximum inputvvattage of the fixture (not simplythe lamp viettage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the vtettage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 2012 Washington State Enerav -ode Compliance Forms for Commercial, Group ..., and > 3 story R2 and R3 Lighting, Motor,and Transformer Permit 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address Red Robin Date 6/22/2015 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2012 Washington State Nonresidential Energy Code. Applicability Code Location Building Department (yes, no, n.a.) Section Component Information Required on Plans Notes LIGHTING CONTROLS (Section C405.2 Yes C405.2.1 Manual lighting Lighting control schedule with type, locations served, 50% ao. 0 controls lighting reduction method Yes Lighting systems automatic shut-off capability - indicate method C405.2.2.1 Automatic time switch and location served on plans. Note locations where automatic ao . 0 controls shutoff is provided by other method (occupancy sensor, daylight controls, etc) N. A • Schedule with locations served - no single override switch Override switching exceeds an area of 5,000 SF N. A. C405.2.2.2 Occupancy sensors Schedule of locations served N. A. C405.2.2.3 Daylight zones N. A. Vertical fenestration Primary and secondary daylight zone areas indicated on plans N. A. Skylights Skylight daylight zone areas indicated on plans N. A. Lighting control schedule with dimming method and locations 405.2.2.3. Daylight zone controls served - no single daylight control zone exceeds 2,500 SF N. A. Specific application Specific application lighting controls are independent of general C405.2.3 controls area lighting and controls for other lighting applications N. A. Means of egress Lighting control schedule with method and locations served. lighting Note luminaires that function as both normal and egress. N. A. Display lighting Lighting control schedule with type and locations served N.A. Accent lighting Lighting control schedule with type and locations served N. A. Hotel/motel guest Lighting control schedule with type and locations served rooms N. A. Supplemental task Lighting control schedule with type and locations served lighting N. A. Non-exempt lighting Lighting control schedule with type, applications served and equipment locations N. A. Non-exempt lighting Lighting control schedule with type, applications served and equipment locations C405.2.4 Exterior lighting Lighting control schedule with g g type, features and location served controls INTERIOR LIGHTING POWER Section C405.5 Yes C405.5.1 Total connected Schedule with fixture types, lamps, ballasts, watts per fixture ao . o li htin ower N. A. Space exceptions Space exceptions taken noted on plans or compliance form N. A. Lighting equipment Equipment exceptions taken noted on plans or compliance form exceptions Yes C405.5.2 Lighting power calculations Compliance form completed — proposed wattage per building N. A. Building Area Method area does not exceed maximum allowed wattage Space -By -Space Compliance form completed — total proposed wattage does not Yes Method exceed maximum allowed wattage Yes C405.4 Exit signs All internally illuminated exits sign are < 5 watts per side EO.0 EXTERIOR LIGHTING POWER Section C405.6 N. A. C405.6.2 Total connected Schedule with fixture types, lamps, ballasts, watts per fixture li htin ower Exterior application Exterior application exceptions taken noted on plans or N. A. exceptions compliance form Lighting power Compliance form completed — proposed wattage for exterior N. A. calculations lighting lus base site allowed does not exceed max. allowed 2012 Washinaton State Enerav —ode Compliance Forms for Commercial. GroUD and > 3 story R2 and R3 Lighting, Motor,and Transformer Permit 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address Rea Robin Date 6/22/2015 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2012 Washington State Nonresidential Energy Code. Applicability Code Location Building Department (yes, no, n.a.) Section Component Information Required on Plans Notes N. A. C405.6.1 Exterior building Schedule with fixture types, lamps, ballasts, watts per fixture; rounds lighting lumens per watt for fixtures > 100 wafts ELECTRICAL POWER SYSTEMS Sections C405.7 ,C405.9, C405.12, C409.2.1 N.A• Electrical energy C409.2.1 consumption — whole Meters provided for whole building electric energy usage building N • A • Electrical energy C405.7 consumption — Individual dwelling unit electricity meters provided dwelling units Yes C405.9 Transformers Indicate transformer size and efficiency on plans 80 . 0 N. A. Variable speed C405.12.1 escalators and moving Variable speed controls provided walks N.A. C405.12.2 Regenerative drives Variable frequency regenerative drives provided for escalators COMMISSIONING Sections C405.13, C408.3, C409.4.4 Yea C405.13 Commissioning Commissioning procedure developed for all applicable systems so . o Yea C408.3 Lighting controls Commissioning plan and functional test procedure developed so . o N • A C409.4.4 Electrical energy Commissioning plan and functional test procedure developed consumption meters N • A • Escalators & moving walks Commissioning plan and functional test procedure developed If "no" is circled for any question, provide explanation: DENNIS WEBB ELECTRIC INC Page 1 of 3 i-lome Inicio en F-spanCiol Contact Safety Washington State Department of Labor & Industries DENNIS WEBB ELECTRIC INC Search L&I ar'.1J A-Z Index Help My Secure L&I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 4530 Crown Lane MALAGA, WA98828 Principals 206-321-8494 WEBB, DENNIS C, PRESIDENT CHELAN County WEBB, PATRICIA R, SECRETARY Webb, Patricia R, TREASURER WEBB, PATRICIA R, AGENT Doing business as DENNIS WEBB ELECTRIC INC WA UBI No. Business type 601 770 609 Corporation Governing persons DENNIS WEBB DENNIS C WEBB; PATRICIA WEBB; PATRICIA R WEBB; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. .............................................................. Meets current requirements. License specialties GENERAL License no. DENNIWE031C4 Effective — expiration 02/24/1997— 02/24/2017 Designated administrator Active. JOHANSON, GEORGE W Meets current requirements. License type License no. Master Electrician JOHANGW973RH Bond ................. OHIO CAS INS CO $4,000.00 Bond account no. 3094786 Effective date 02/24/1997 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations ........._..._................_..._..._......... https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601770609&LIC=DENNIWE03IC4&SAW= 11/02/2015 0 SEPARATE PERMIT REQUIRED FOR: Q City of Tuwft BUILDING DAIS I REVi5lti�lS Yl No ,shall be made to the scope of work without prior approval of Tukwila Building Division. MOTE: Revisions will require a plan submidd and may include additional plan review fees. 0 0 N RLECOPY 0 s_ Permit wo, ✓07rim E N T E R W Y�� w 17300 SOUT® Plan review w N approval is to errors and orn ions. CL U Approval oaf consi.ruction not atttFmrize � W A T 1 1 r1\`W LAUA YI 1,01 the 'on of any a ed or . R ipt O O I of . . ♦ approved Field O cn By. S" T 0 R E #2` 0' 00' S Oft- U T H Ca"E N T E R`® Date: /s m 1 City of TuWa BT PROTOTYPE REMODEL BUIWI G.DIVISI w ,� � o CODE REVIEW INTERIOR SCOPE OF WORK (FRONT OF HOUSE ONLY): GENERAL NOTES FIRE DEPARTMENT NOTES as <ri m z sx ms= BAR RECONFIGURATION: ALL DIE WALL, BAR TOP, AND BAR EQUIPMENT; NEW SEATING 1. DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENT. 1. PROVIDE NEW AND/OR RE -LOCATE EXTINGUISHERS PER LOCAL FIRE ' APPLICABLE CODES CONFIGURATION; ACCESSIBLE PLATFORM LIFT. d3 BUILDING: 2012 INTERNATIONAL BUILDING CODE & 2012INTERNATIONAL EXISTING BUILDING CODE NEW LIGHTING PACKAGE. DEPARTMENT / AUTHORITY DIRECTION. I_1_I �. 2. IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY ARCHITECT OF RECORD AS SOON ¢ y xz s ' + • NEW FLOOR FINISHES AND PAINT. iD 2. ALL EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL. se ssE �: MECHANICAL: 20121NTERNATIONALMECHANlCAL CODE AS POSSIBLE. $ E ¢- SOME NEW WALL &SOFFIT FRAMING AND RELOCATION OF HVAC DIFFUSERS IN ORDER TO r x ELECTRICAL: WASHINGTON CITIES ELECTRICAL CODE & 2008 NATIONAL ELECTRICAL CODE SERVE NEW SEATING & DECOR LAYOUT. 3. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT SPECIAL s ; � � ' Y' .Y r' � � � 1 3. FOR BIDDING PURPOSES; WHERE CONFLICTS EXIST BETWEEN DRAWING DETAILS & KNOWLEDGE OR EFFORT (NO DEAD BOLTS, NO SLIDING BOLTS, ETC.) ' NO WORK WILL BE PERFORMED IN KITCHEN AND PREP AREAS. q ACCESSIBILITY: [CC 2009 / ANSI A117.1 W SPECIFICATIONS, THE MORE STRINGENT SPECIFICATION SHALL APPLY. �x O 4. AN OCCUPANT CONTENT SIGN SHALL BE POSTED IN EACH ASSEMBLY ROOM K { ENERGY: 20121NTERNATIONAL ENERGY CONSERVATION CODE 4, GENERAL CONTRACTOR (G.C.) IS RESPONSIBLE FOR ALL ASPECTS OF BUILDING HAVING AN OCCUPANT CONTENT OF 50 OR MORE. a . EXTERIOR SCOPE OF WORK: , ^ CO W CONSTRUCTION DELINEATED IN THESE DRAWINGS UNLESS SPECIFICALLY NOTED E (UNDER A v EXISTING BUILDING FOOTPRINT TO REMAIN 00 tton STOREFRONT GLAZING SYSTEM COMPRISING THE "GREENHOUSE TO BE REPLACED U i.iJ vJ r _ 5. MAINTAIN MIN. 44" AISLES TO EXIT OR PUBLIC WAY.N�, QO OTHERWISE. GENERAL SEPARATE PERMIT, BY G.C.); EXISTING "GREENHOUSE STRUCTURE TO REMAIN. Z U .rs EXISTING EXTERIOR AWNINGS TO BE RE -MOVED. 6. IF REQUIRED, PROVIDE EXIT SIGNS ABOVE EXITS WITH MIN. 3/4" X 6" LETTERS LIGHTED ON � a 5. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS ON DRAWINGS FOR CONFLICTS CONTRASTING BACKGROUND. CODE DESCRIPTION ALLOWED/REQUIRED EXISTING/MAINTAINED NEW EXTERIOR PAINT. Q PRIOR TO CONSTRUCTION. THE GENERAL CONTRACTOR WILL NOTIFY THE ARCHITECT OF ess r r' NEW EXTERIOR SIGNAGE UNDER SEPARATE PERMIT (N.LC.). O (� _ USE GROUP CLASSIFICATION (303.1) A-2, ASSEMBLY O ANY DISCREPANCIES. 7. EXIT SIGNS MUST BE INTERNALLY ILLUMINATED. �/ N UJ BUILDING CONSTRUCTION TYPE (TABLE 503): VB (E_iSTING) NOTE TO G.C: 6. ANY DAMAGE BY G.C. OR SUBCONTRACTOR TO EXISTING ASPHALT PAVEMENT AND/OR 8. IF REQUIRED, PROVIDE TWO (2) SEPARATE POWER SUPPLIES FOR EXIT SIGNS � Q _ FIRE SPRINKLERS (504.2): FULLY SPRINKLERED IT IS ASSUMED THAT THE G.C. SHALL PERFORM THE WORK AS ILLUSTRATED WITHIN THE O W EXISTING LANDSCAPING OUTSIDE OF CONSTRUCTION LIMIT LINE SHALL BE REPAIRED AT CONFORMING TO CODE SECTION. : s PERMITTED DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN THE EVENT THAT W C'7 NO COST TO OWNER. p :: NUMBER OF STORIES (TABLE 503): (1) ALLOWED (1) EXISTING SITE CONDITIONS PREVENT THE WORK FROM BEING COMPLETED AS ILLUSTRATED HEREIN SO02 9. PROVIDE EMERGENCY EXIT LIGHTING PROVIDING AN AVERAGE VALUE OF ONE _ s THAT ANY MODIFICATIONS (IF NECESSARY) CAN BE MADE. ANY DEVIATIONS FROM THE ~ 7. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES AND WORK AREAS SHALL BE LEFT IN FOOT CANDLE AT FLOOR LEVEL. ? BUILDING HEIGHT (TABLE503): 40'-0' ALLOWED 26A' EXISTING 5173tt BUI PERMITTED DRAWINGS WILL NOT BE ACCEPTED AND THE CONTRACTOR SHALL A CLEAN (BROOM) CONDITION DAILY. r r ' RECONFIGURE THE WORK AT HIS OWN EXPENSE AS REQUIRED TO BE IN CONFORMANCE GROSS BUILDING AREA (TABLE 503; 506.3) 6,000 SF + (3 x 6,000 SF) = 9700 SF EXISTING 10. ADDITIONAL EXIT SIGNS WILL BE PROVIDED AS/IF DIRECTED BY THE CITY Rf zasx�e Zeox.r 24,000 SF ALLOWED WITH THE PERMITTED DOCUMENTS. THE ARCHITECT WILL NOT ACCEPT, CERTIFY OR 8. GENERAL CONTRACTOR SHALL PROVIDE A LIST OF SUBCONTRACTORS TO RED ROBIN INSPECTOR. DOCUMENT WORK DONE THAT DOES NOT CONFORM WITH THE PERMITTED DOCUMENTS FOR GOURMET BURGERS. u-• S 3 +PATIO AREA: 650 SF EXISTING THE PURPOSES OF OBTAINING ANY TYPE OF MUNICIPAL APPROVAL DUE TO UNAUTHORIZED rt� s tiV 1 1. GENERAL CONTRACTOR RESPONSIBLE FOR SMOKE DENSITY RATING AND T s & REVISIONS. MINIMUM EGRESS AISLE WIDTH (1018.2): 44' MINIMUI4 44' MINIMUM 9_ GENERAL CONTRACTOR SHALL COMPLY WITH ALL STATE AND LOCAL RULES AND FLAME SPREAD RATING OF MATERIALS USED. REGULATIONS CONCERNING LICENSING WHICH THE APPLICABLE GOVERNING st S 18(1Lt5r NUMBER OF EXITS 1015.1 : 2 REQUIRED 4 EXISTING V! AUTHORITY MAY HAVE ADOPTED. 12. INTERIOR WALL AND CEILING FINISHES FOR ASSEMBLY AREAS SHALL NOT =Rni 3. ( ) O O •9 SCOPE OF WORK N EXIT WIDTH (1005.1): 383 x D.2' = 76.6' REQUIRED 140' EXISTING V co EXCEED AN END POINT FLAME SPREAD RATING OF 200 OR CLASS C.€� y SCALE: NONE �r"°i N 13. DECORATIVE MATERIALS SHALL BE FLAME RETARDANT. AREA MAP to P SITE LOCATION v c "' FIRE SPRINKLER SYSTEM: G.C. TO CONFIRM SYSTEM REQUIREMENTS WITH LOCAL CALCULATED OCCUPANT LOAD (TABLE 1004.1.2) ( CERTIFICATION THEREOF SHALL BE PROVIDED. EXITS, EXIT SIGNS, FIRE ALARM f' CURRENT W d W MUNICIPALITY WHEN MODIFYING EXISTING IF NECESSARY DUE TO NEW WORK) STATIONS, HOSE CABINETS AND EXTINGUISHER LOCATIONS SHALL NOT BE 4 FUNCTION (OCCUPANT FACTOR) CALCULATED OCCUPANCY DRAWING SHEET # SHEET NAME � �r CD LL CONCEALED BY DECORATIVE MATERIALS. SCALE: N.T.S. I. THE FIRE PROTECTION CONTRACTOR SHALL SUBMIT PLANS AND WAITING 1 STANDING AREA (5 SF PER PERSON): 235 SF/5 SF=47 PERSONS General o CALCULATIONS SEPARATELY TO THE LOCAL FIRE DEPARTMENT FOR REVIEW AND PERMIT AS NEEDED. 14. ALL DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME-RETARDANT WAITING BENCHES (18' PER PERSON): 450' 118' = 25 PERSONS _ in NO1 CONDITION. OWNER FURNISHED (B.O.) AND NOT IN C1.0 COVER SHEET L o M CONTRACT (N.I.C.) ITEMS: DINING -TABLES &CHAIRS (15 SF PER PERSON): 1672 SF / 15 SF = 112 PERSONS c N LSl .0 LIFE SAFETY PLAN m 15. INSULATION SHALL BE INSTALLED TO MEET FLAME SPREAD AND SMOKE DINING -FIXED BOOTHS &BANQUETTES (24' PER co FIRE ALARM SYSTEM: (G.C. TO CONFIRM SYSTEM REQUIREMENTS WITH LOCAL DENSITY REQUIREMENTS PER LOCAL CODE. B O PERSON}: 3834" 124" =160 PERSONS • �"7 eNv F MUNICIPALITY WHEN MODIFYING EXISTING IF NECESSARY DUE TO NEW WORK) O Items shown or noted as "B.O." or "By Owner' on the drawings and/or in the Architecture � w 16. G.C. TO PROVIDE AND POST OCCUPANT CONTENT SIGN NEAR FRONT DOOR. specifications shall be furnished by Owner to Contractor/subcontractor for installation by DINING - SEATS a COUNTER (18- PER PERSON): 465' / 18' = 26 PERSONS r I . THE FIRE ALARM CONTRACTOR SHALL SUBMIT PLANS AND CALCULATIONS PER LOCAL ORDINANCE REQUIREMENTS. Contractor/subcontractor as part of the construction contract. Contractor/subcontracto DID DEMOLITION PLAN STORAGE i MECHANICAL (300 SF PER PERSON): 675 SF 1300 SF = 3 PERSONS SEPARATELY TO THE LOCAL FIRE DEPARTMENT FOR REVIEW AND PERMIT_ shall receive, to the extent of unloading at the job site as required, store and be AS NEEDED. 17. EXIT SIGNAGE SHALL BE PROVIDED AND MAINTAINED FOR CORRIDORS AND responsible to the extent of carrying necessary insurance to cover items in case of theft- KITCHEN & BAR SERVICE 200 SF PER PERSON): D1.1 DEMOLITION REFLECTED CEILING PLAN AISLE WAYS LEADING TO EXITS 1N ACCORDANCE WITH SECTION. SIGNAGE SHALL p g n ( ) 1050 SF / 200 SF = 6 PERSONS STATE: "OBSTRUCTIONS, INCLUDING STORAGE, SHALL NOT BE PLACED IN THE fire, loss, malicious damage and other miscellaneous damage. Refer to Section 01018 of OFFICE 100 SF PER PERSON 2. THE FIRE ALARM SYSTEM IS REQUIRED TO BE AUDIBLE THROUGHOUT THE the Building Specifications for a complete ( ) 323 SF 1100 SF = 4 PERSONS AS1.0 ARCHITECTURAL SITE PLAN BUILDING. ADDITIONAL ALARM DEVICES MAY BE REQUIRED UPON TESTING REQUIRED WIDTH OF AN EXIT OR EXIT PASSAGEWAY" g p p ete list of B.O. Items. OF THE SYSTEM. ONLY REQ.-D. WHEN THERE ARE 100+ HEADS BUILDING OCCUPANCY: 383 PERSONS ( ) 18. FIRE DEPARTMENT FINAL INSPECTION REQUIRED. SCHEDULE INSPECTIONS A2.0 FURNISHING PLAN TWO (2) DAYS IN ADVANCE OR PER AHJ. .I.0 PATIO (15 SF PER PERSON) 650 SF / 15 SF = 44 PERSONS Revisions 3. THE FIRE ALARM SYSTEM IS REQUIRED TO BE MONITORED BY AN Items shown or noted "(NIC)" on the drawings and/or in the specifications shall be A2.1 REFLECTED CEILING PLAN APPROVED CENTRAL STATION. furnished and installed by Owner under separate contract, except as described % 19. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE AND COMBUSTIBLE hereinafter. Refer to Section 01018 of the Building Specifications for a complete list of LIQUIDS, FLAMMABLE AND COMPRESSED GASES, AND OTHER HAZARDOUS EXISTING PLUMBING FIXTURES A2.2 DECOR PLAN .. 4. LOCATE FIRE ALARM CONTROL PANEL IN THE OFFICE ROOM. THE MATERIALS SHALL COMPLY WITH LOCAL FIRE CODE REGULATIONS. N.I.C. Items. REQUIRED DUCT SMOKE DETECTORS SHALL BE TIED INTO THE BUILDING rUn CODE DESCRIPTION (TABLE 2902.1) REQUIRED EXISTING !MAINTAINED A2.3 FABRIC PLANrRIEVEM X�"•� -� �� �' MONITORING SYSTEM. NOTE: B.O. and N.I.C. Items are noted through out the construction documents. If a 20. FIRE BLOCKS SHALL OCCUR AT THE FOLLOWING LOCATIONS: discrepancy exists the specifications shall prevail. MEN'S LAVATORIES (1 PER 200) (2) REQ'D (2) EXISTING A2.4 FLOOR FINISH PLAN T r ^ 9i3+0 5. EXISTING FIRE / ALARM SYSTEM TO BE MODIFIED BY G.C. A. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED WOMEN'S LAVATORIES (1 PER 200) (2) REQ'D (2) EXISTING Q I r.. V itt�! �V✓ SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH A3.0 EXTERIOR ELEVATIONS 6. IN THE EVENT THAT STROBE SIGNALING DEVICES ARE RELOCATED, G.C. TO CONFIRM VERTICAL AND HORIZONTAL. MEN'S TOILETS I URINALS (1 PER 75) (3) REQ'D (3) WC 1(2) URINAL EXISTING p Q LOCATION IS APPROVED BY FIRE DEPARTMENT. B. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL WOMEN'S TOILETS (1 PER75) (3) REQ'D (5) WC EXISTING A4.0 INTERIOR ELEVATIONS SEF U Q SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. KEY NOTES LEGEND: EMPLOYEE RESTROOMS (1) UNISEX EXISTING A4.1 INTERIOR ELEVATIONS ACCESSIBILITY NOTES: I.XX ITEMS NOTED AS "I.XX" ARE THE RESPONSIBILITY OF G.C. U.N.O. AND ARE A5.0 INTERIOR SECTIONS & D TAILS of i ukikila CONSIDERED PROJECT STANDARD SCOPE OF WORK. G.C. SHALL p�,�,u DIN/� p1I�/ISIOp� 1. WALKS, HALLS, CORRIDORS, PASSAGEWAYS, AISLES OR OTHER COORDINATE WITH RED ROBIN PM & RED ROBIN VENDORS. A5.1 BAR DETAILS &DOORS 10371 CIRCULATION SPACES SHALL HAVE 80" MINIMUM CLEAR HEADROOM. !� FIRE DEPARTMENT NOTES o CODE REVIEW (EXIST. BUILDING) Structural REGISTER L 2.XX ITEMS NOTED AS "2.XX" ARE THE RESPONSIBILITY OF G.C. U.N.O. THESE ITEMS R TE 2. GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN ARE CONSIDERED DEFERRED MAINTENANCE ITEMS. ALL ITEMS NOTED ACCESSIBLE ROOMS AND SPACES, INCLUDING FLOORS, WALKS, RAMPS, SCALE: NONE SCALE: NONE SO.0 GENERAL NOTES STAIRS, AND CURB RAMPS, SHALL BE STABLE, FIRM, AND SLIP -RESISTANT. SHALL BE A SEPARATE BID FROM PROJECT STANDARD SCOPE. SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION G.C. TO VERIFY WITH RED ROBIN PM IF CERTAIN ITEMS NOTED WILL HAVE _ 3. OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGES BETWEEN AN ALLOWANCE ALLOCATED PRIOR TO BID SUBMISSION. TENANT: ARCHITECT: S1.0 FOUNDATION PLAN NJAMIN R. U ETA 27" AND 80" ABOVE THE FINISH FLOOR SHALL PROTRUDE NO MORE THAN 4" STATE OF WAS NGTON INTERIOR/ Electrical INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES. OBJECTS SECTION TAG- RED ROBIN GOURMET BURGERS BENJAMIN R. URUETA X EXTERIOR 3.XX ITEMS NOTED AS "3.XX"ARE THE RESPONSIBILITY OF G.C. AS PART OF THE 6312 S. FIDDLERS GREEN CIRCLE 21 1 EAST BROAD STREET MOUNTED AT OR BELOW 27" ABOVE FINISH FLOOR MAY PROTRUDE ANY AMOUNT. SEE DWG. AS COLUMN X-X NOTED O LINE XX FINISH TAG- CONSTRUCTION CONTRACT. THESE ITEMS ARE CONSIDERED ADA EO.O ELECTRICAL SYMBOLS & NOTES SEE FINISH UPGRADES REQUIRED TO MEET LOCAL CODES. ALL ITEMS NOTED SHALL BE SUITE 200 NORTH GREENVILLE, SC 29601 4. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL CONSIST OF A GREENWOOD VILLAGE, CO 80111 864.232.8200 WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO LEGEND A SEPARATE BID FROM PROJECT STANDARD SCOPE. G.C. TO VERIFY WITH EI A ELECTRICAL FLOOR PLAN & NOTES COLOR NO. 15090 IN FEDERAL STANDARD 599b. RED ROBIN PM IF CERTAIN ITEMS NOTED WILL HAVE AN ALLOWANCE ALLOCATED PRIOR TO BID SUBMISSION. DESIGN MANAGER: MEP ENGINEER: E2.1 ELECTRICAL PANEL SCHEDULES & DC'FJTY OF TUKWILA 5. THE CENTER OF THE GRIP OF THE OPERATING HANDLE OF CONTROLS OR SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR DETAIL TAG Plumbing CHRIS LASKY SCHNACKEL ENGINEERS, INC. X REVISION FABRIC TAG PHONE: 303.846.5489 3035 SOUTH 72ND STREET P1.0 PLUMBING PLAN &NOTES JUN . 2 3 2015 AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS SHALL NOT BE MORE SEE DWG. AS THAN 48" ABOVE THE FINISH FLOOR OR WORKING PLATFORM. X-X AX TAG FAB-X SEE FABRIC NOTED LEGEND SUPPLEMENTAL DOCUMENTS: EMAIL: claskyCredrobin.com OMAHA, NE 68124 6. THE CENTER OF FIRE ALARM INITIATING DEVICES (BOXES) SHALL BE REFER TO SUPPLEMENTAL DOCUMENTS FOR DESIGN INTENT, INSTALLATION GUIDELINES, BEST 402.391.7680 Kitchen IRi�' CBj�'I'R LOCATED 48" A.F.F., WORKING PLATFORM, GROUND SURFACE, OR SIDEWALK. PRACTICES, SOURCING, SHOP DRAWINGS. CUT SHEETS, & SPECIFICATIONS. PROJECT MANAGER: K1.0 BAR EQUIPMENT PLANS, SCHEDULE, & ELEVATIONS 7. IF EMERGENCY WARNING SYSTEMS ARE REQUIRED, THEY SHALL ACTIVATE SUPPLEMENTAL #1 -MILLWORK A MEANS OF WARNING FOR THE HEARING IMPAIRED. DECOR TAG- SUPPLEMENTAL #2- DECOR Specifications X ELEVATION ELEVATION TRACY FOLLMER 8. STROBE SIGNALING DEVICES REQUIRED FOR THE HEARING IMPAIRED TAG BENCHMARK D•7 SEE DECOR SUPPLEMENTAL #3- FURNISHINGS QUALITY PROJECT MANAGEMENT X LEGEND SUPPLEMENTAL #4- LIGHTING SPI.I SPECIFICATIONS SHALL BE STATE FIRE MARSHAL APPROVED AND LISTED. PHONE: 602.909.7544 Drawn By Checked By SUPPLEMENTAL #5 - MATERIALS & FINISHES SUPPLEMENTAL #6 - AUDIO / VISUAL EMAIL:tfollmersgpmilc.com SP1.2 SPECIFICATIONS JLB BRU X PLAN KEYNOTE MULTIPLE MILLWORK SP1.3 SPECIFICATIONS Scale Date AS NOTED X 1.XX (PROJECT SCOPE) TAG -SEE SP1.4 S TIONS Job No. X X ELEVATION pA,3 A-1 TAG 2.XX (DEFERREDMAINT-) MILLWORK 14225 '�('� X 3.XX (ADA SCOPE) LEGEND U IV L/ `/ 11 Sheet No. GENERAL NOTES 3 DRAWING SYMBOL LEGEND 5 PROJECT RESPONSIBILITY MATRIX 6 REVISION LOG PROJECT CONTACTS U INDEX OF DRAWINGSC1 u SCALE: NONE SCALE: NONE SCALE: NONE SALE: NONE SCALE: NONE SCALE: NONE ° LIGHT FIXTURE SCHEDULE �® TYPE MANUFACTURER CATALOG DESCRIPTION LAMPS MOUNTING VOLTS WATTS LFOA UTON LT-526-B (1) SORAA MR16-50-BO3-120-927-2 TRACK 120 10 LFOB UTON LT-526-B 0 (1) SORAA MR16-50-BO3-120-927-2 TRACK 120 10 LFOC LITON LT-526-B LONG CORD O (1) SORAA MR16-50-BO3-120-927-6 TRACK 120 10 LF6 ELITE BHVR6INC-12/ 6101-CL-WH LED26DP385830/25 RECESSED 120 26 LF7 HALO H99TAT/945 LED7DP206827/20H0 RECESSED 120 7 LF11 PROGRESS P5741-318L ACCULAMP ALEBR40 SURFACE 120 17 LF19 LITON LH991CA-LLF-GU24 (1) LRELD402SN RECESSED 120 13 LF42 VARALUZ 9121730-20 (1) GE LEDIIDAV3/827 TRACK 120 11 LF42A VARALUZ 9121730-20 (1) GE LEDIIDAV3/827 TRACK 120 11 LF42B VARALUZ 9121730-15 (1) GE LEDIIDAV3/827 TRACK 120 11 LF42C VARALUZ 9121730-10 (1) GE LEDIIDAV3/827 TRACK 120 11 LF50 TECH LIGHTING 700FIFIRFRC m CK0011-FJ-SC 700FJHASPB (1) 35W XENON (INCLUDED) TRACK 12 35 LF51 TECH LIGHTING 700FJFIRFKS m CK0011-FJ-SC 700FJHASPB (1) 35W XENON (INCLUDED) TRACK 12 35 LF52 TECH LIGHTING 700MOSS604C 1 SORRA MR16-50-B01-12-927-2 TRACK 12 10 LF60 SAPPHIRE CUSTOM BOTTLE PENDANT MR16 LAMPS CEILING 120 150 LF65 TWICEBRIGHT SL12011-WH BS (1) 7W LED CEILING 120 7 LF68 LIfON LIGHTING LRCLD802WWF-100-R12-DIN-T30; 800L 30K LED INCLUDED CEILING 120 12 IZES A PLENUM RETURN AIR 1. WHERE THE MECHANICAL DESIGN IJTIL 35. ALL CONDUIT &OTHER ELECTRICAL EQUIPMENT MUST BE CEILING DESIGN, ALL EQUIPMENT AND MATERIALS INSTALLED WITHIN SUPPORTED FROM THE STRUCTURE ABOVE. ABSOLUTELY NO THE PLENUM RETURN CEILING MUST MEET THE FLAME SPREAD AND EQUIPMENT MAY BE SUPPORTED FROM THE CEILING. ANY SMOKE DEVELOPED RATINGS OF 25/50 AND BE APPROVED FOR USE IN OPENINGS CUT INTO THE ACOUSTICAL CEILING TILES SHALL BE PLENUM RETURN CEILINGS. COORDINATE PLENUM CEILING LOCATIONS CUT TO THE EXACT SIZE REQUIRED IN ORDER TO MAINTAIN ANY WITU TUC UrrIWAMTrAi rntiTRACTnR- I IIMTNAiRFS THAT ARE ----___-- _._-..__ Ar4inma, DISPERSED MANUFACTURED WITH A METAL HOUSING MEET THIS REQUIREMENT AND 36, ELECTRICAL DESIGN HAS BEEN BASED ON THE INSTALLATION OF ARE NOT REQUIRED TO BE PLENUM RATED UNLESS INDICATED 75 DEGREES C CONDUCTORS CONNECTED TO TERMINAL LUGS & OTHERWISE. EQUIPMENT, U.L. LISTED FOR A MINIMUM OF 75 DEGREES C. 2. COORDINATE ALL DEVICE LOCATIONS AND CIRCUIT ROUTING WITHIN CONDUCTORS TERMINATED ON EQUIPMENT WITH A LOWER RATING ANY MILLWORK WITH MILLWORK VENDOR PRIOR TO ROUGH -IN. 3. COORDINATE THE CONNECTIONS OF ALL EQUIPMENT PROVIDED BY (60 DEGREES C) OR NO RATING SHOWN, SHALL HAVE CONDUCTOR OTHERS WITH THE CONTRACTOR PROVIDING THE EQUIPMENT PRIOR TO SIZE INCREASED TO CONFORM TO N.E.C. TABLE 310.16 & U.L. ROUGH -IN. THIS INCLUDES, BUT IS NOT LIMITED T0, MECHANICAL NO. 489 REQUIREMENTS. EQUIPMENT, KITCHEN EQUIPMENT, AUDIO/VISUAL EQUIPMENT, FIRE 37. ALL EMPTY CONDUITS SHALL BE PROVIDED WITH A PULL WIRE SUPPRESSION SYSTEM EQUIPMENT, FIRE ALARM EQUIPMENT, ETC. OR STRING. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE THE 38. AT THE CONCLUSION OF THIS PROJECT, THE ELECTRICAL APPROPRIATE DISCONNECTING MEANS FOR, AND TO MAKE THE FINAL CONTRACTOR SHALL PROVIDE AN UPDATED TYPEWRITTEN CONNECTION TO, ANY HARDWIRED EQUIPMENT. THE ELECTRICAL DIRECTORY INSIDE EACH PANEL BOARD, AND PANEL LABEL, CONTRACTOR IS ALSO RESPONSIBLE TO PROVIDE AN APPROPRIATE PROPERLY IDENTIFYING EACH CIRCUIT USED & THE SPECIFIC CORD AND PLUG FOR ANY CORD -AND -PLUG CONNECTED EQUIPMENT THAT LOAD SERVED. IS NOT EQUIPPED WITH AN INTEGRAL CORD AND PLUG. 39. WHENEVER POSSIBLE, RACEWAYS AND CONDUITS SHALL BE 4. SEE PANEL SCHEDULES FOR INFORMATION ON CIRCUITS THAT ARE TO INSTALLED CONCEALED. BE ROUTED THROUGH CONTACTORS OR RELAYS FOR CONTROL. 5. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PRESERVING THE 40. CONTRACTOR SHALL COORDINATE INSTALLATION OF UTILITIES FIRE RATING OF ANY FIRE -RATED CEILING ASSEMBLIES BY ABOVE THE CEILING TO PROVIDE THE GREATEST POSSIBLE PROVIDING THE APPROPRIATE FTRE-RATED LUMINAIRE TENTS AS CLEARANCE FOR INSTALLATION OF & FUTURE CHANGES TO THE MANUFACTURED BY TENMAT OR NELSON FIRESTOP OR BY BUILDING MECHANICAL, PLUMBING, &FIRE SPRINKLER SYSTEMS, ETC. FIRE -RATED ENCLOSURES AROUND EACH LUMINAIRES THAT IS CONDUIT &PIPE TO BE RUN TO MAXIMIZE USE OF CEILING RECESSED INTO THE FIRE -RATED ASSEMBLY. COORDINATE FIRE- SPACE FOR USE BY OTHER TRADES. RATED CEILING ASSEMBLY LOCATIONS WITH THE ARCHITECTURAL 41. PROVIDE A BLACK RECEPTACLE WITH A BLACK COVER PLATE. IN THE DRAWINGS. BAR, EXPO, DINING AREA, AND RESTROOMS. PROVIDE A GRAY OR 6. ALL LUGS, TERMINALS, ETC. IN ELECTRICAL DISTRIBUTION WHITE RECEPTACLE WITH A STAINLESS STEEL COVER PLATE IN EQUIPMENT SHALL BE LISTED FOR A MINIMUM OF 75 DEGREE C KITCHEN AREAS. CONDUCTORS. TERMINATIONS LISTED FOR ONLY 60 DEGREE C 42. ANY EXISTING CONDITIONS INDICATED IN THIS SET OF DRAWINGS CONDUCTORS ARE NOT PERMITTED. ARE BASED ON INFORMATION PROVIDED BY OTHERS AND POSSIBLE 7. BRANCH CIRCUITS RATED AT 20 AMPS AT 120 VOLTS THAT ARE LIMITED FIELD VERIFICATION. THE CONTRACTOR SHALL ADJUST FOR LONGER THAN 75 FEET SHALL BE #10 AWG MINIMUM TO OFFSET ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE VOLTAGE DROP. . OWE, 8. BRANCH CIRCUITS RATED AT 20 AMPS AT 120 VOLTS THAT ARE 43. THE CONTRACTOR SHALL VISIT THE PROJECT SITE, REVIEW EXISTING LONGER THAN 150 FEET SHALL BE #8 AWG MINIMUM TO OFFSET CONDITIONS AGAINST THE CONTRACT DOCUMENTS, AND FAMILIARIZE VOLTAGE DROP. HIMSELF WITH THE WORK PRIOR TO BIDDING AND START OF THE 9. BRANCH CIRCUITS RATED AT 20 AMPS AT 277 VOLTS THAT ARE WORK. BY SIGNING THE CONTRACT, THE CONTRACTOR ACKNOWLEDGES LONGER THAN 150 FEET SHALL BE #10 AWG MINIMUM TO OFFSET THE SITE VISIT HAS BEEN COMPLETED AND THE EXISTING VOLTAGE DROP. CONDITIONS ARE ACCEPTED. 10. CONDUCTORS #12 AWG AND SMALLER SHALL BE SOLID. CONDUCTORS 44. IT IS NOTED THAT NOT ALL ITEMS REQUIRED TO BE DEMOLISHED ARE #10 AWG AND LARGER ARE PERMITTED TO BE STRANDED. NECESSARILY SHOWN. THE CONTRACTOR SHALL BE REQUIRED TO 11. CONTRACTOR SHALL CAREFULLY REVIEW CONTRACT DOCUMENTS FIELD VERIFY AND FIELD DETERMINE THE SCOPE OF THE DEMOLITION INCLUDING DRAWINGS, SPECIFICATIONS &LEASE. INFORMATION WORK PRIOR TO BID. REFER ALL QUESTIONS TO THE A/E PRIOR TO REGARDING WORK -FOR THE VARIOUS TRADES &SUBCONTRACTORS BID FOR CLARIFICATION. THROUGHOUT THE DOCUMENTS & CANNOT BE 45. THE CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF EXISTING IS ACCURATELY DETERMINED WITHOUT REFERENCE TO THE FULL SET EQUIPMENT, DEVICES, AND LUMINAIRES AS INDICATED AND/OR AS OF DOCUMENTS. REQUIRED TO ALLOW FOR INSTALLATION AND CONSTRUCTION OF THE I= INSTALLATION OF ALL LUMINAIRES SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND ACCORDING TO NEC AND LOCAL CODE 12 CONTRACTOR SHALL COORDINATE INSTALLATION OF UTILITIES ABOVE NEW Wes• REMOVE ALL EQUIPMENT, DEVICES, LUMINAIRES, CONDUITS, SUPPORTS, HANGERS, ETC. THAT ARE NOT SHOWN AND ARE REQUIREMENTS. � VERIFY EXACT MOUNTING HEIGHT, LOCATION, FINISH, AND COLOR WITH ARCHITECT PRIOR TO ROUGH -IN. ALL LUMINAIRES SHALL BE AIMED PER THE THE CEILING TO PROVIDE THE GREATEST POSSIBLE CLEARANCE FOR INSTALLATION OF &FUTURE CHANGES IN MECHANICAL EQUIPMENT. 46. REQUIRED TO BE REMOVED IN ORDER TO COMPLETE THE NEW WORK. PHASING OF ELECTRICAL DEMOLITION SHALL FOLLOW THAT OF THE ARCHITECT'S REQUIREMENTS. COORDINATE A TIME TO MEET WITH THE OWNER & ARCHITECT TO AIM/ ADJUST LUMINAIRES. ALL LUMINAIRES USED FOR DECOR ARE TO BE MOUNTED AS CLOSE TO TRACK AS POSSIBLE -NO EXTENSIONS, UNLESS NOTED OTHERWISE. CONDUIT & PIPE TO BE RUN TO MAXIMIZE USE OF CEILING SPACE GENERAL CONTRACTOR. COORDINATE REMOVAL OF ELECTRICAL WORK ® PADDLE FAN SHALL BE SUPPORTED FROM STRUCTURE ABOVE AS RECOMMENDED BY MANUFACTURER. FOR ANY FUTURE WORK. WITH OTHER CONSTRUCTION ACTIVITIES AND THE REQUIREMENTS OF ® LUMINA.RE SHALL HAVE A SELF-CONTAINED BATTERY BACK-UP RATED FOR A MINIMUM OF 90 MINUTES OF OPERATION. 13, REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT PLACEMENT OF LIGHTING FIXTURES & ANY OTHER EQUIPMENT 47. THE OWNER. WHERE ITEMS ARE SHOWN HATCHED, ITEMS ARE TO BE DEMOLISHED ® EXIT LIGHT WITH APPROPRIATE MOUNTING, NUMBER OF FACES, PANEL COLOR AND ARROW DIRECTION BASED ON EACH FIXTURES LOCATION, APPLICATION INSTALLED IN CEILING SYSTEM. PRIOR TO FRAMING, CONTRACTOR ALONG WITH THEIR ASSOCIATED BOXES, CONDUITS, CONDUCTORS, AND THE REQUIREMENTS OF ALL LOCAL CODES AND ORDINANCES. SHALL VERIFY WEIGHT OF DECORATIVE FIXTURES WITH ARCHITECT OR SUPPORTS, AND HANGERS UNLESS INDICATED OTHERWISE. ® NOT USED. m PROVIDE JUNO DUAL CIRCUIT TRACK IN LENGTHS AS REQUIRED PER PLAN. TRACK IS TO BE MOUNTED LEVEL, TIGHT TO DECK. PROVIDE ALL OWNER AND SHALL PROVIDE ADDITIONAL FRAMING AS REQUIRED FOR 48. ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY. CONDUCTORS SHALL BE REMOVED FROM THE NECESSARY LIVE END CONNECTORS, STRAIGHT CONNECTORS, FLEXIBLE CONNECTORS, JOINERS, ETC. AS REQUIRED FOR A COMPLETE AND OPERATIONAL SUPPORT, ITEM TO BE DEMOLISHED TO THE SOURCE DEVICE. SYSTEM. REFER TO DETAIL 6/EO.0 FOR ADDITIONAL INFORMATION. TRACK IS TO BE POWERED THROUGH CURRENT LIMITING END -FEEDS AND CIRCUIT 14. CONTRACTOR TO VERIFY PLACEMENT OF ALL DEVICES SHOWN ON FLOORSURRENT BELOOVERW RACEWAYS WHICH ARE INSTALLED IN OR BELOW FLOORS OR WITHIN BREAKERS. THE ELECTRICAL CONSTRUCTION DOCUMENTS WITH ARCHITECTURAL, WALLS MAY BE ABANDONED, BUT ALL OVERHEAD OR EXPOSED RACEWAYS ® ALL LUMIAIRES SHALL BE FURNISHED BY VILLA LIGHTING AND INSTALLED BY ELECTRICAL CONTRACTOR. MECHANICAL, PLUMBING, &KITCHEN DRAWINGS PRIOR TO FINAL SHAH BE REMOVED. EXPOSED RACEWAYS TO BE ABANDONED SHALL BE I = LIGHT STRIPS IN 2', 4'. 6', & 8' LENGTHS, 2.43 WATTS PER FOOT AT INPUT OF TRANSFORMER. 50' MAX. LENGTH PER TRANSFORMER. LISTED AS PLACEMENT. KITCHEN DRAWINGS TAKE PRECEDENT. D AT LEAST 2" INTO THE REMOVED AND SHALL BE CUT OR CHISELED COMPLYING WITH UL 1598 & CSA C22.2 NO. 250, LUMINAIRES CATEGORY LISTING NO. E212177, SUITABLE FOR WET (OUTDOOR) LOCATIONS. REFER TO MANUFACTURER'S INSTRUCTIONS FOR EXACT METHODS OF INSTALLING TRANSFORMERS AND LED STRIP LIGHTS. SEE POWER PLAN (E1.2) FOR 15. CONTRACTOR TO VERIFY THAT ALL PARTS ARE INCLUDED WITH OWNER FURNISHED EQUIPM=NT & REPORT ANY MISSING ITEMS. 49. WALL OR FLOOR AND THE OPENING GROUTED SMOOTH. THE OWNER SHALL HAVE SALVAGE RIGHTS TO ANY ITEMIS THAT ARE TO TRANSFORMER RECEPTACLES. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL DETAILS. 16. REFER TO SHEET 'EO.O' FOR ELECTRICAL SYMBOL LEGEND. BE DEMOLISHED. THOSE ITEMS THAT THE OWNER WISHES TO SALVAGE SHALL BE CAREFULLY REMOVED AND STORED IN A LOCATION AS ® FIXTURES SHALL INCLUDE HEX LOWER ACCESSORY ® PROVIDE TRACK MOUNTING UNLESS NOTED OTHERWISE ON FLOOR PLAN. VERIFY LENGTH OF TRACK WITH LIGHTING LAYOUT. 17. CONTRACTOR SHALL INCREASE CONDUCTOR SIZE ACCORDINGLY WITH NEC TABLE 310.16 IN CASES WHERE VOLTAGE DROP EXCEEDS 3% DIRECTED BY THE OWNER. ALL OTHER ITEMS OF DEMOLITION SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED ® MONOPOIN7 MOUNTED PENDANTS SHALL BE MOUNTED WITH "FUSION JACK CANOPY WITH 4" ROUND FLUSH" MODEL # CK0011-FJ-S, TRACK MOUNTED 18. EXPOSED CONDUIT AT THE OPEN CEILING SHIALL BE HELD TIGHT TO FROM THE SITE. PENDANTS SHALL BE MOUNTED WITH "FREEJACK TRACK ADAPTER- MODEL # 700FJHASPB STRUCTURE, RAN AT RIGHT ANGLES TO STRUCTURE, & LOCATED SO 50. WHERE DEMOLITION WORK WILL INTERRUPT CIRCUIT CONTINUITY TO ® PROVIDE WITH LOW -VOLTAGE FlLIX DRIVER #OT96W/24V/LIMN/JBX AS TO KEEP IT AS INCONSPICUOUS AS POSSIBLE. OTHER AREAS OF THE FACILITY THAT ARE TO REMAIN IN OPERATION, LIGHT FIXTURES WILL BE FURNISHED BY VILLA LIGHTING. (THROUGH RED ROBIN NATIONAL ACCOUNT 19. CONTRACTOR SHALL BE REQUIRED TO ASSEMBLE ALL LIGHT FIXTURES. THEN RACEWAY AND WIRING SHALL BE INSTALLED TO MAINTAIN THOSE AREAS IN COMPLETE OPERATION. PROVIDE TEMPORARY CONNECTIONS2 LIGHTING VENDOR). NOTE: VILLA LIGHTING IS THE NATIONAL ACCOUNT LIGHTING VENDOR FOR RED . ALL PADDLE FANS SHALL BE SUPPORTED FROM STRUCTURE ABOVE AS REQUIRED BY THE NEC AND RECOMMENDED BY THE AS REQUIRED. COORDINATE ANY INTERRUPTIONS WITH THE OWNER AT LEAST TWO WEEKS PRIOR AND ACCOMMODATE THE OWNER'S NEEDS AS ROBIN. CONTACT IS DANIEL LUDWIG PH: (800)-325-0963 EXT. 133 21. ALL POWER CONDUITS SHALL HAVE 2-#12 AND 1- 12 GROUND IN # 51. REQUIRED. MAINTAIN CONTINUITY OF EXISTING CIRCUITS AS REWIRED TO EMAIL ADDRESS: DLUDWIG®VILLALIGHTING.COM. 1/2" CONDUIT, UNLESS OTHERWISE NOTED. PROVIDE POWER TO REMAINING EWIPMENIT, DEVICES, AND 22 DEVICES SHALL BE COMMERCIAL SPECIFICATION GRADE OR BETTER. LUMINAIRES THAT ARE NOT BEING REMOVED. TRANSFORMER SCHEDULE TYPE MANUFACTURER MODEL # DR PLEXINEON ADV10OW24V TRE300 TECH LIGHTING 700AT300EL 23. CONTRACTOR SHALL FURNISH ALL LAMPS NOT INCLUDED WITH LIGHTING PACKAGE. THE LAMPS SHALL BE OSRAM SYLVANIA, PHILLIPS OR GE. SUBMIT CUT SHEETS FOR LAMPS. THE CONTRACTOR SHALL PROVIDE SHATTER SHIELDS, LENSED FIXTURES OR PROTECTED LAMPS (NOT INCUDED WITH LIGHTING PACKAGE) ABOVE FOOD PREPARATION, WORK AND STORAGE AREAS. 24. EMERGENCY AND EXIT LIGHTING SHALL MEET ALL LOCAL CODES AND ORDINANCES. EACH EMERGENCY FIXTURE SHALL BE PROVIDED WITH A MINIMUM OF 90 MINUTES OF EMERGENCY -BATTERY BACK-UP 52. WHERE EXISTING DEVICE OR JUNCTION BOXES MUST REMAIN IN EXISTING WALLS OR CEILINGS (SUCH AS FOR CIRCUITS THAT MUST BE MAINTAINED TO OTHER AREAS), THEN THEY SHALL BE FITTED WITH BLANK COVERPLATES. 53. WHERE DISTRIBUTION OR BRANCH CIRCUIT EQUIPMENT (PANELBOARDS, SWITCHBOARDS, ETC.) IS TO BE REMOVED, THEN ALL CIRCUITS WHICH FEED ITEMS TO REMAIN SHALL BE RECONNECTED TO NEW DISTRIBUTION OR BRANCH CIRCUIT EQUIPMENT. REFL.i ALL QUESTIONS TO THE A/E FOR CLARIFICATION. 54. EXISTING PANEL DIRECTORIES SHALL BE UPDATED TO ACCURATELY POWER REFLECT CONDITIONS AFTER WORK IS COMPLETE. UNUSED CIRCUIT 'SPARE-' 25. REFER TO SHEET 'A5.1' FOR LIGHT FIXTURE MOUNTING HEIGHTS. BREAKERS SHALL BE LABELED AS 55. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN IN OPERATION 26. REFER TO SHEET 'E0.0' FOR LIGHT FIXTURE SCHEDULE AND NOTES. THROUGHOUT CONSTRUCTION. AUTOMATIC SMOKE DETECTORS IN THE 27. CONNECT EMERGENCY FIXTURES TO UNSWITCHED SIDE OF LOCAL AREA OF CONSTRUCTION SHALL BE DISCONNECTED AND TEMPORARILY LIGHTING CIRCUIT PRIOR TO ANY SWITCHES, CONTACTORS, OR REPLACED WITH HEAT DETECTORS WHEN THE SPACE IS STAFFED BY DIMMERS PER NEC 700.12(f). THE CONTRACTOR IN ACCORDANCE WITH THE APPROVED FIRE SAFETY 28• ALL EXISTING LIGHT FIXTURES WITHIN THE LIMITS OF CONSTRUCTION PROCEDURES OF THE OWNER AND THE LOCAL FIRE MARSHALL, BUT SHALL BE REPAIRED TO A LIKE -NEW CONDITION, THOUROUGHLY SHALL BE REACTIVATED WHENEVER THE SPACE IS NOT OCCUPIED BY CLEANED, AND RELAMPED. COORDINATE WITH VILLA LIGHTING. ANY THE CONTRACTOR. AUTOMATIC SMOKE DETECTORS SHIALL BE EXISTING LIGHT FIXTURES THAT ARE DAMAGED BEYOND REPAIR SHALL PROTECTED FROM DUST AND DIRT ACCUMULATION BY REMOVING THE BE REPLACED WITH AN IDENTICAL LIGHT FIXTURE. DEVICE FROM ITS BASE DURING THOSE TIMES WHEN TIE SYSTEM IS 29. ALL WORK SHALL CONFORM WITH THE NATIONAL ELECTRICAL ALLOWED TO BE OUT OF OPERATION. (I.E. ASBESTOS, PCB'S, ETC.) ARE CODE AND ALL STATE AND LOCAL CODES AND ORDINANCES. 56. IF HAZARDOUS MATERIALS WHERE MINIMUM CODE REQUIREMENTS ARE EXCEEDED BY THE ENCOUNTERED AT ANY TIME DURING CONSTRUCTION IN THE WORK A STOP WORK IMMEDIATELY AND CONTACT THE A/E OR THE ELECTRICAL SYMBOL LEGEND (SOME MAY NOT BE USED) SYMBOL DESCRIPTION SYMBOL DESCRIPTION PANELBOARD, UTILITY POWER -0 WALL MOUNTED JUNCTION/OUTLET BOX ® POWESWITCH DISTRIBUTION POWER R eJ F FLUSH FLOOR MOUNTED JUNCTION/OUTLET BOX gMETER AND SOCKET OJ C CEILING MOUNTED JUNCTION/OUTLET BOX -e WALL MOUNTED SINGLE RECEPTACLE CEILING MOUNTED PHOTOCELL WALL MOUNTED DUPLEX RECEPTACLE $MOD RATTED WHEN USED UNLESS INDICATED CONTTROLOORI DISCONNECPTINNG R MEANS. SWITCH INCLUDING COMBINATIONS THEREOF: WALL MOUNTED QUADRUPLEX RECEPTACLE WALL MOUNTED DEDICATED DUPLEX RECEPTACLE MODIFIERS. 3: 3--SWAY (SPOT). 4: 4-WAY. D: DIMMER. F. BOX COVER UNIT BUSSMANN SSU OR STY SERIES. G: GLOW HANDLE (HIANDLE GLOWS WHEN SWITCH IS OFF). H: HORIZONTALLY MOUNTED. K: KEY OPERATED. M: MANUAL MOTOR CONTROLLER WITH OVERLOAD HEATER. 031: OCCUPANCY SENSOR. OS2: DUAL -RELAY OCCUPANCY SENSOR. P: PILOT LIGHT (PILOT ON WHEN SWITCH IS ON). T: TIMER. SENSOR. �; LOW VOLTAGE. OR: OVERRIDE. OT: OVERRIDE WITH TIMER. WP: WEATHERPROOF DTC- SPDT CENTER OFF MAINTAINED CONTACT. DTI: SPDY, CENTER OFr, MOMENTARY CONTACT. LOWERCASE LETTER: CONTROL LUMINAIRE WITH SAME LETTER. ng WALL MOUNTED DUPLEX RECEPTACLE, ONE RECEPTACLE SWITCHED OF FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE F FLUSH FLOOR MOUNTED DEDICATED DUPLEX RECEPTACLE Em FLUSH FLOOR MOUNTED QUADRUPLEX RECEPTACLE ®C CEILING MOUNTED DUPLEX RECEPTACLE -OOR-0 WALL MOUNTED SPECIAL RECEPTACLE, NEMA CONFIGURATION AS NOTED WALL MOUNTED RANGE RECEPTACLE, NEMA 14-50R UNLESS INDICATED OTHERWISE WALL MOUNTED SPECIAL RECEPTACLE, NEMA CONFIGURATION AS NOTED PEDESTAL MOUNTED RECEPTACLE, SEE PLAN fOR TYPE XX/X FUSES SAFETY SWITCH, SIZE AS INDICATED ON PLAN MULTI -OUTLET ASSEMBLY 1 CORD AND PLUG XX/X FUSES COMBINATION MAGNETIC MOTOR STARTER AND DISCONNECT SWITCH, SIZE AS INDICATED ON PLAN , MOTOR ,,---�, BRANCH CIRCUITING, CONCEALED IN WALL OR CEILING 0mv TELEPHONE OUTLET, FLOOR 1 BRANCH CIRCUITING, CONCEALED IN OR UNDER FLOOR ®C TELEPHONE OUTLET, CEILING BRANCH CIRCUITING, EXPOSED ® TELEPHONE OUTLET, WALL �sSG�, HOMERUN TO PANEL. THE NUMBER OF ARROWS INDICATES THE NUMBER OF CIRCUITS. TWO WIRES UNLESS NOTED OTHERWISE. GROUND WIRE IS REQUIRED BUT NOT COUNTED IN HASH MARKS. a DATA OUTLET, FLOOR mC DATA OUTLET, CEILING 7 CONDUIT STUB 0 DATA OUTLET, WALL O CIRCUIT TURNING UP ❑S COMBINATION TELEPHONE AND DATA OUTLET, FLOOR )III( CIRCUIT TURNING DOWN EEC COMBINATION TELEPHONE AND DATA OUTLET, CEILING BELL v COMBINATION TELEPHONE AND DATA OUTLET, WALL B�i BUZZER ® SIZE ASIINDICATTEEDOONBDRAWINGS ' CHIME ❑TV TELEVISION OUTLET, FLOOR QS SPEAKER, CEILING TV C TELEVISION OUTLET, CEILING -♦�S SPEAKER, WALL 7d TELEVISION OUTLET, WALL eS G SPEAKER, GROUND -MOUNTED 0 PUSHBUTTON STATION, ONE BUTTON VC VOLUME CONTROL UI PUSHBUTTON STATION, TWO BUTTON rA-M-'P-1 SOUND SYSTEM AMPLIFIER P ---I PUSHBUTTON STATION, THREE BUTTON ® LOW VOLTAGE CONTROL TRANSFORMER ® RELAY TC AUTOMATIC TIMECLOCK PC PHOTOCELL FF-AC-P-1 FIRE ALARM CONTROL PANEL Ell FIRE ALARM HORN, WALL MOUNTED FE-VA-C-1 FIRE ALARM VOICE EVACUATION PANEL D4 FIRE ALARM SPEAKER, WALL MOUNTED FAA FIRE ALARM REMOTE ANNUNCIATOR ® FIRE ALARM STROBE, WALL MOUNTED ZAM FIRE ALARM ZONE ADDRESSABLE MODULE EN AND STROBECWALL COMBINATION [0 FIRE ALARM MANUAL PULLSTATION FIRE ALARM COMBINATION SPEAKER AND STROBE, WALL MOUNTED AUTOMATIC SMOKE DETECTOR, WALL MOUNTED DIC FIRE ALARM HORN, CEILING MOUNTED AUTOMATIC SMOKE DETECTOR, CE"JNG MOUNTED L!_f4C FIRE ALARM SPEAKER, CEILING MOUNTED (DD AUTOMATIC 0 0 0 AM FIRE ALARM RELAY (INTEGRAL OR FIELD -INSTALLED) ®C FIRE ALARM STROBE, CEILING MOUNTED RTS DUCT SMOKE DETECTOR REMOTE TEST SWITCH E<C AND STROBE CEILINGnMOUNTTED -� AUTOMATIC HEAT DETECTORWALL MOUNTED , 94C FIRE ALARM COMBINATION SPEAKER AND STROBE, CEILING MOUNTED AUTOMATIC HEAT DETECTOR, CEILING MOUNTED PIV SUPERVISED POST INDICATOR VALVE F FIRE SPRINKLER FLOW SNATCH Lr F' FIRE SPRINKLER ALARM BELL F MONITORING SPRINKLERTAMPER SUPERVISCORY CONNECTION N Q FIRE ALARM MAGNETIC DOOR HOLDER REQUIREMENTS INDICATED IN THE SPECIFICATIONS AND ON ARE OWNER. THESE DRAWINGS, THE DRAWINGS AND SPECIFICATIONS SHALL 57. REMOVE CABLING BACK TO SOURCE FOR ALL TEL/DATA OUTLETS BEING TAKE PRECEDENCE. (IN THE CASE OF CODE CONFLICT REMOVED. DIRECTION SHALL BE TAKEN FROM THE MORE STRICT OF THE 58. LUMINAIRES MARKED "E" ARE EXISTING LUMINAIRES THAT ARE TO CONFLICTING CODES). REMAIN IN PLACE. ALL EXISTING LUMINAIRES WITHIN THE LIMITS 30. THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND OF CONSTRUCTION SHALL BE REPAIRED TO A LIKE -NEW CONDITION, BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND ALL THOROUGHLY CLEANED, AND RELAMPED. ANY EXISTING LUMINAIRES OTHER FACTORS WHICH MAY AFFECT THE EXECUTION OF THE THAT ARE DAMAGED BEYOND REPAIR SHALL BE REPLACED WITH AN WORK. INCLUDE ALL RELATED COSTS IN THE INITIAL BID IDENTICAL LUMINAIRE. PROPOSAL. 59. LUMINAIRES MARKED "RR" ARE EXISTING LUMINAIRES THAT ARE TO 31. CONCEAL ALL ELECTRICAL WIRING AND RACEWAYS WHERE BE OR HAVE BEEN RELOCATED. ALL LUMINAIRES DESIGNATED FOR CONSTRUCTION PERMITS. EXPOSED HORIZONTAL RACEWAY RUNS RELOCATION SHALL BE DISCONNECTED FROM EXISTING BRANCH ON ROOF IN EXCESS OF 5 FEET ARE NOT PERMITTED. EXPOSED CIRCUIT, REMOVED FROM EXISTING AREA, STORED, REPAIRED TO A RACEWAY IS PERMITTED WHERE STRUCTURE IS EXPOSED TO VIEW LIKE -NEW CONDITION, INSTALLED IN REMODELED AREA, AND IN THESE LOCATIONS CAREFULLY INSTALL RACEWAYS RECONNECTED, THOROUGHLY CLEANED, AND RELAMPED. ANY RELOCATED LUMINAIRES THAT ARE DAMAGED BEYOND REPAIR SHALL BE PARALLEL TO WALLS, BEAMS, AND COLUMNS. 32. ALL ELECTRICAL EQUIPMENT, CONDUIT, AND LIGHTING REPLACED WITH AN IDENTICAL LUMINAIRE. FIXTURES SHALL BE ANCHORED OR SUPPORTED IN ACCORDANCE WITH THE LOCAL SEISMIC REQUIREMENTS. 33. VERIFY THE LOCATIONS OF ALL RECEPTACLES, LUMINAIRES, E UIPMENT CONNECTIONS CONDUIT STUB -UPS SIGNS ETC OCCUPANCY SENSOR SCHEDULE SYMBOL OCCUPANCY SENSOR MFR./MODEL NUMBER DESCRIPTION/FUNCTION DIGITAL DUAL TECHNOLOGY (PASSIVE INFRARED AND ULTRASONIC) CEILING CEILING -MOUNTED OCCUPANCY WATTSTOPPER #DT-300 WITH #BZ50 POWER PACK, OR EQUAL, UNLESS OCCUPANCY SENSOR TURNS LIGHTS ON AND OFF BASED ON OCCUPANCY; 74 C SENSOR, DUAL TECHNOLOGY NOTED OTHERWISE INTEGRAL PHOTOSENSOR PREVENTS LIGHTS FROM TURNING ON WHEN ADEQUATE NATURAL LIGHT IS AVAILBLE 120V OR 277V SINGLE RELAY WALL SWITCH SENSOR AUTOMATICALLY TURNS WALL SWITCH OCCUPANCY WATTSTOPPER #DSW-100 OR EQUAL, ALL LIGHTS ON AND OFF BASED ON OCCUPANCY, MANUAL SWITCH OVERRIDES AUTOMATIC FUNCTION UNTIL NEXT AUTOMATIC EVENT; INTEGRAL S1 SENSOR - ON/OFF UNLESS NOTED OTHERWISE PHOTOSENSOR PREVENTS LIGHTS FROM TURNING ON WHEN ADEQUATE NATURAL LIGHT IS AVAILBLE 120V OR 277V DUAL RELAY WALL SWITCH SENSOR AUTOMATICALLY TURNS PARTIAL LIGHTING ON BASED ON OCCUPANCY AS INDICATED ON THE PLANS; WALL SWITCH OCCUPANCY WATTSTOPPER #DSW-200 OR EQUAL, MANUAL SWITCH TURNS REMAINING LIGHTING ON AS INDICATED ON THE S2 SENSOR, DUAL RELAY UNLESS NOTED OTHERWISE PLANS, WALL SWITCH SENSOR TURNS ALL LIGHTING OFF AFTER TIMEOUT; INTEGRAL PHOTOSENSOR PREVENTS LIGHTS FROM TURNING ON WHEN ADEQUATE NATURAL LIGHT IS AVAILBLE ABBREVIATIONS AND MODIFIERS (SOME MAY NOT BE USED) SYMBOL DESCRIPTION AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE BF BELOW FLOOR NIC NOT IN CONTRACT LINO UNLESS NOTED OTHERWISE N.F. NON -FUSED GFCI GROUND -FAULT CIRCUIT INTERRUPTER GFPE GROUND -FAULT PROTECTION OF EQUIPMENT SPST SINGLE POLE, SINGLE THROW DPST DOUBLE POLE, SINGLE THROW 3PST THREE POLE, SINGLE THROW 4PST FOUR POLE, SINGLE THROW SPDT SINGLE POLE, DOUBLE THROW DPDT DOUBLE POLE, DOUBLE THROW 3PDT THREE POLE, DOUBLE THROW 4PDT FOUR POLE, DOUBLE THROW NO NORMALLY OPEN NC NORMALLY CLOSED GND GROUND EGC EQUIPMENT GROUNDING CONDUCTOR IGC ISOLATED GROUND CONDUCTOR GEC GROUNDING ELECTRODE CONDUCTOR AHJ AUTHORITY HAVING JURISDICTION A/E . ARCHITECT/ENGINEER NEC NATION'L ELECTRICAL CODE (NFPA 70) NEMA NAT10N..L ELECTRICAL MANUFACTURERS ASSOCIATION UL UNDERWRITERS LABORATORIES NRTL NATIONALLY RECOGNIZED TESTING LABORATORY +XX" MOUNTING HEIGHT MODIFIER LC LOCKABLE IN CLOSED POSITION MODIFIER LID LOCKABLE IN OPEN POSITION MODIFIER ST SHUNT TRIP MODIFIER EM EMERGENCY OR EMERGENCY LIGHT MODIFIER NL UNSWITCHED NIGHTLIGHT LUMINAIRE MODIFIER WP WEATHERPROOF MODIFIER IRS RIGID STEM MOUNT (PEDESTAL FROM FLOOR) MODIFIER RP RIGID PENDANT MOUNT (FROM CEILING) MODIFIER DC DROP CORD MOUNT (FROM CEILING) MODIFIER PT POKE-THRU MODIFIER H HORIZONTAL MOUNT MODIFIER HG HOSPITAL GRADE MODIFIER TR TAMPER RESISTANT MODIFIER IG ISOLATED GROUND MODIFIER IF ILLUMINATED FACE MODIFIER P PILOT LIGHT MODIFIER SP SURGE PROTECTION MODIFIER GFCI GROUND -FAULT CIRCUIT INTERRUPTER MODIFIER AFCI ARC -FAULT CIRCUIT INTERRUPTER MODIFIER SR SHOW WINDOW RECEPTACLE MOUNTED WITHIN 18 INCHES OF TOP OF SHOW WINDOW CR CONTROLLED RECEPTACLE MODIFIER 12 "m I AV 41% z @01 Q 0 O 0 4# L- LLJ LLJ IZ 0 D 0 0 n m I Ln V) LU W H w 0 Ln ((D r W C45 N 00 V) Z J LU >- 0 3�� � a) L- >- I 0 0- "' W V a � -D Z c 00 00 U (n U Q` - m = Q W 0 °3 W U V) Do'LU Z 1 W W cY S� LU W W ^ ~ a - Oi5 �j W E u r- T .� c u O LJ REVIEWED FOR COMPLIANCE &; NPPA 70 N EWC, SEP 18 2015 . RECEIVED CITY OF TUKWILA 1= o M � i &- . Q PRIOR TO ROUGH -IN. SEE THE ARCHITECTURAL AND KITCHEN SE DRAWINGS FOR ADDITIONAL INFORMATION. In City of '��� 300 34. INSTALL GREEN EQUIPMENT GROUND WIRE IN ALL POWER AND BRANCH CIRCUIT RACEWAYS (SEE SPECIFICATIONS). BUILDING DIVISION z $ PERMIT CENTER I'll�.: o CO LIGHT FIXTURE SCHEDULE AND NOTES 2 GENERAL ELECTRICAL NOTES I SYMBOLS LEGEND 3 SCALE: NONE FILEII ,E SCALE: NONE Revisions SCALE: NONE ELECTRICAL SYSTEM SECTION 16000 ELECTRICAL SYSTEM CONTINUED }N '�` s. �. ', / G NEW MATERIALS FIXTURES DEVICES AND ACCESSORIES NECESSARY ALL CONDUIT AND RACEWAY SYSTEMS SHALL BE INSTALLED WITH SEPARATE GREEN EQUIPMENT � " ": �� �•1. `,, a' `�s'�'1 THE WORK INCLUDES PROVIDING FOR A COMPLETE FUNCTIONING ELECTRICAL SYSTEM. ALL WORK SHALL BE IN ACCORDANCE WITH GROUND CONDUCT(IR. CONDUIT SYSTEM IS NOT TO BE USED AS THE SOLE GROUNDING MEANS. LOCAL CODES OR ORDINANCES AND SUBJECT TO INSPECTION. CONDUCTORS: INS ATED SOFT ANNEALLED 98% PURE COPPER WITH COLOR CODING, B AND S jj"��� V zn f` COMPLY WITH ALL LAWS APPLYING TO ELECTRICAL INSTALLATIONS AND WITH THE MOST RECENT GAGE, #10 AND SMALLER TO BE SOLID, #8 AND LARGER TO BE STRANDED, MINIMUM #12 UNLESS Q 1O o SLOPING ROOF DECK EDITION OF THE NATIONAL ELECTRICAL CODE, ADA, APPLICABLE SECTIONS OF OTHER NFPA, OSHA, OTHERWISE INDICATED. ALUMINUM CONDUCTOR SHALL NOT BE ALLOWED. THHN SHALL NOT BE USED LIFE SAFETY CODES AND RECOMMENDATIONS, AND THE INTERIM AMENDMENTS IN EFFECT AT THE UNDERGROUND, AT SERVICE ENTRANCE, OUTSIDE, OR IN WET LOCATIONS. ALL INSULATION SHALL BE Q TIME OF THE PROPOSAL. ALL MATERIALS USED SHALL BE NEW AND SHALL CONFORM TO THE RATED FOR 600 V AND TYPES AS FOLLOWS: STANDARDS ESTABLISHED BY THE UNDERWRITERS LABORATORIES INCORPORATED. Q 10 AND SMALLER: THWN OR THHN CURRENT CIRCUIT \ THE INTENT OF THE DRAWINGS IS TO INDICATE THE GENERAL EXTENT OF WORK REQUIRED FOR THE 8 TO #4/0: THWN OR THHN LIMITING NUMBER `THREADED ROD ATTACHED TO DECK- PROJECT. THE DRAWINGS FOR ELECTRICAL WORK ARE DIAGRAMMATIC, SHOWING THE LOCATION, TYPE, SERVICE ENTRANCE: USE-RHW Q AMPERAGE DEVICES AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT OVER 4/0 ORDINARY SERVICE: THHN OR XHHN ""�' MEASUREMENTS. PROVIDE ALL FIXTURES, DEVICES, ACCESSORIES, OFFSETS, AND MATERIALS OVER 4/0 WET OR HOT SERVICE: XHHW NECESSARY TO FACILITATE THE SYSTEM'S FUNCTIONING AS INDICATED BY THE DESIGN AND THE WIRE THRU FLUORESCENT FIXTURES OR WITHIN 3' OF HEATING EQUIPMENT: THHN T-,..c6A A P4-28 TRACK PARALLEL TO FLOOR, EQUIPMENT FURNISHED BY OTHERS. A P4-30 TIGHT TO BOTTOM OF 12" ELECTRICAL CONTRACTOR IS TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING. ALLOWANCES DEVICES SHALL BE MANUFACTURED BY LEVITON "INDUSTRIAL GRADE" OR EQUAL. STANDARD DUPLEX oy sc,r A P4-32 BRANCH DUCTWORK, WITH ARE TO BE INCLUDED FOR UNFORESEEN EXISTING CONDITIONS THAT MAY EFFECT THE RECEPTACLES SHALL BE GROUNDING TYPE, 20A, NEMA WD-2 STANDARD 5-20R, SIDE WIRED, 6y. OF WASp�`�' A P4-34 INCREASING DISTANCE TO CONTRACTOR'S SCOPE OF WORK. MINOR DEVIATIONS REQUIRED FOR ACCOMPLISHING THE INTENT OF LEVITON #5342. LIGHT SWITCHES SHALL BE 20 AMP, 120 VOLT, LEVITON #1221-2. WHERE ,Sti :, G;k DECK AS PITCH RISES. THIS DESIGN IS TO BE INCLUDED IN THIS ALLOWANCE. SWITCHES ARE GROUPED, PROVIDE SINGLE MULTI -GANG PLATES. 0 yQ' f--' 0� n P4-36 SPECIAL PLATES: PROVIDE STAINLESS STEEL PLATES AT ALL RECEPTACLES AND LIGHT SWITCHES �T z 6A P4-31 ELECTRICAL CONTRACTOR TO FIELD VERIFY ALL EXISTING UNDERGROUND UTILITIES. ANY ITEM INSTALLED IN THE KITCHEN, WORK AREA, STORAGE ROOMS, AND CHECK IN -OUT AREA. C", =' m_ SA P4-33 O SECTION OF TRACK DAMAGED BY THIS CONTRACTOR SHALL BE REPAIRED IMMEDIATELY AND AT NO COST TO THE THE ELECTRICAL CONTRACTOR SHALL REVIEW MATERIALS IMMEDIATELY UPON TIME OF DELIVERY AND L *TRACK PARALLEL TO FLOOR OWNER. IMMEDIATELY REPORT ANY DAMAGED OR MISSING PIECES. ,1 9A P4-35 ELECTRICAL DESIGN HAS BEEN BASED ON THE INSTALLATION OF 75'C CONDUCTORS CONNECTED TO A 3154, 2A P4-2 TERMINAL LUGS AND EQUIPMENT, U.L. LISTED FOR A MINIMUM 75'C. CONDUCTORS TERMINATED ON LAYOUT BRANCH CIRCUIT WIRING AND ARRANGEMENT OF HOME RUNS FOR MAXIMUM ECONOMY AND �P CIS en w� TRANSFORMER EQUIPMENT OR DEVICES WITH A LOWER RATING (60'C) OR NO RATING SHOWN, SHALL HAVE EFFICIENCY. INCREASE WIRE SIZE IF VOLTAGE DROP EXCEEDS 3% OR 100 FEET OF LENGTH. 2A P4-4 CONDUCTOR SIZE INCREASED TO CONFORM TO NEC TABLE 310.16 AND U.L. N0. 489 CONCEAL WIRING SYSTEM ABOVE SUSPENDED CEILINGS OR IN WALL OR FLOOR CONSTRUCTION • EN REQUIREMENTS. WHERE POSSIBLE. INSTALL CONDUITS PARALLEL TO BUILDING LINES, AND TO CLEAR ALL OPENING, R--EJACK DEPRESSIONS, PIPES, DUCTS, STRUCTURE, ETC. FEMALE CONNECTOR CABINETS SHALL BE ONE PIECE CODE GAGE GALVANIZED STEEL WITH MOUNTING STUDS, WIRING FIXTURE FREEJACK GUTTERS OF AMPLE SIZE AND KNOCKOUTS FOR CONDUIT CONNECTIONS AS REQUIRED. BUS BARS INSTALL CONDUIT CONTINUOUS BETWEEN BOXES AND CABINETS WITH NO MORE THAN FOUR 90 D&w 06122115 CURRENT LIMITING PANEL SHALL BE 98� CONDUCTIVE COPPER, ALUMINUM, OR COPPER -CLAD ALUMINUM. FRONTS SHALL BE DEGREE BENDS. SECURELY FASTEN IN PLACE WITH STRAPS, HANGERS AND STEEL SUPPORTS AS con A2609 MALE CONNECTOR PANEL MODEL#: JUNO CLS12 ONE PIECE CODE GAGE STEEL WITH ADJUSTABLE FASTENERS. PROVIDE A PLASTIC COVERED REQUIRED. DO NOT SUPPORT CONDUIT FROM SUSPENDED CEILING GRID OR SUSPENSION WIRES. TYPEWRITTEN SCHEDULE IDENTIFYING ALL BRANCH CIRCUITS INSIDE EACH CABINET. RECESSED REAM CONDUIT ENDS BEFORE INSTALLATION AND THOROUGHLY CLEAN BEFORE INSTALLATION. �� ) LIGHT CORDS SHIPPED ALL THE SAME CABINETS SHALL BE INSTALLED WITH A MINIMUM OF TWO 3/4" SPARE CONDUITS STUBBED UP TO OPENINGS SHALL BE PLUGGED OR COVERED TO KEEP CONDUIT CLEAN. TERMINALS ON SWITCHES LENGTH, CONTRACTOR SHALL CUT ACCESSIBLE CEILING SPACE. AND OUTLET SHALL NOT BE USED TO "FEED THRU" TO THE NEXT SWITCH OR OUTLET. CORDS TO APPROPRIATE LENGTH IF GROUNDING SYSTEM: PERMANENTLY AND EFFECTIVELY GROUND ALL METALLIC CONDUIT, SUPPORTS, ADJUSTING AND TESTING: ALL ELECTRICAL EQUIPMENT SHALL BE ADJUSTED AND TESTED FOR NECESSARY CABINETS, PANELBOARDS AND SYSTEM NEUTRAL CONDUCTORS. MAINTAIN CONTINUITY OF EQUIPMENT PROPER OPERATION. COMPLETED WIRING SYSTEM SHALL BE FREE FROM SHORT CIRCUITS. GROUND THROUGHOUT THE SYSTEM. GROUND CLAMPS SHALL BE APPROVED TYPE, SPECIFICALLY DESIGNED FOR GROUNDING. WHERE GROUNDING CONDUCTOR IS ENCLOSED IN CONDUIT, GROUND TOUCH-UP OR REFINISH DAMAGED SURFACES OF FIXTURES AND EQUIPMENT EXPOSED TO VIEW. CLAMP SHALL BE OF A TYPE WHICH GROUNDS BOTH CONDUCTOR AND CONDUIT. ALL CIRCUITS IN REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF LUMINAIRES AND FLEXIBLE METAL OR PLASTIC CONDUIT SHALL INCLUDE A GROUND WIRE SIZED IN ACCORDANCE WITH OTHER CEILING MOUNTED EQUIPMENT. NATIONAL ELECTRICAL CODE. Drawn By Checked By FOR EQUIPMENT FURNISHED BY OWNER OR OTHER CONTRACTORS; ELECTRICAL CONTRACTOR SHALL CONDUIT SHALL BE SIZED TO COMPLY WITH NEC FOR NUMBER AND SIZE OF CONDUCTORS VERIFY EXACT LOAD, TYPE OF CONNECTION AND MOUNTING HEIGHT FOR EACH BOX OR EQUIPMENT TLH GRS INSTALLED. PROVIDE ELECTRICAL METAL TUBING (EMT) MEETING FS W-0563, OR FLEXIBLE METAL ITEM TO BE INSTALLED. ALL HARD -WIRED CONNECTIONS TO EQUIPMENT SHALL BE MADE WITH Scale Date CONDUIT (IN LENGTHS 6' OR LESS) FOR INTERIOR LOCATIONS. EMT CONNECTORS AND COUPLING FLEXIBLE LIQUID TIGHT METAL CONDUIT WITH GREEN EQUIPMENT GROUNDING CONDUCTOR INSTALLED SHALL BE SET -SCREW TYPE. CLAMP CONDUIT TO BOXES WITH BUSHING INSIDE AND LOCKNUT INSIDE RACEWAY. EQUIPMENT GROUNDING CONDUCTOR SHALL BE BONDED AT BOTH ENDS. NONE OUTSIDE. ("MC" & "AC" TYPE CABLES MAY BE USED IN NON- EXPOSED AREAS, EXCEPT IN THE 0 BAR, EXPO, AND COOKUNE AREAS. "MC" & "AC" CABLE MAY ONLY BE USED WHERE ALLOWED BY r STATE AND LOCAL CODES). 1 Sh'' D LF51 DETAIL ELECTRICAL SPECIFICATIONS i.1 .0 4 CURRENT LIMITING PANEL b i ' -- I I LF50 AN 5 SCALE: NONE mm I , I I LIGHTING FLOOR PLAN LF19 LF19 a a RECEIVED CITY OF TUKWILA SEP 0 1 2015 PERMIT CENTER O LOCATE CONTROLS FOR NEW "YUMMM SIGN" IN THE EXPO AREA OCONTRACTOR SHALL PROVIDE CURRENT LIMITING PANEL BETWEEN THE BRANCH CIRCUIT BREAKERS AND LIGHTING EQUIPMENT. VERIFY EXACT LOCATION WITH OWNER PRIOR TO ROUGH —IN. SEE DETAIL 4/EO.O FOR ADDITIONAL INFORMATION. O3 CONTRACTOR SHALL ROUTE CIRCUIT THROUGH CURRENT LIMITING PANEL, REFER TO 4/EO.0 FOR CURRENT LIMITER SIZES. O PROVIDE TECH LIGHTING TRANSFORMER MODEL #: 700AT300EL. REFER TO 3/E0.0 FOR TRANSFORMER SCHEDULE. 50 COORDINATE EXACT REQUIREMENTS FOR TIN TACKER & YUMMM SIGN WITH MANUFACTURER PRIOR TO ROUGH —IN. O CONTRACTOR SHALL DISCONNECT ALL EXISTING COMPONENTS SERVING THE EXISTING HOST COUNTER AND RELOCATE/RECONNECT IN THE NEW LOCATION FOR THE HOST COUNTER. VERIFY EXACT REQUIREMENTS IN FIELD PRIOR TO ROUGH —IN. O7 CAP ALL ELECTRICAL ORIGINALLY USED FOR GAME EQUIPMENT IN ENTRY AREA. PROVIDE BLANK FACEPLATES. PROVIDE TAMPER PROOF RECEPTACLE IN PLACE OF THE OUTLET FURTHEST FROM THE NEW CHALKBOARD. Og CONTRACTOR SHALL VERIFY LOCATION OF EXISTING LIGHTING SWITCHBANK. CONTRACTOR SHALL PROVIDE NEW DIMMING SWITCHES NEAR EXISTING CONTROLS AND ENGRAVE NEW DIMMING SWITCHES. Og ELECTRICAL EQUIPMENT LOCATED AT THE BAR SHALL BE CONNECTED VIA CONDUIT THROUGH THE BAR DIE TO THE NEAREST FULL HEIGHT WALL, UP TO ACCESSIBLE CEILING AND CONNECTED TO CIRCUIT(S). 10 PROVIDE 3/4" CONDUIT WITH PULL STRING THROUGH HALF WALL, TO NEAREST FULL —HEIGHT PARTITION A EXTEND CONDUIT OVERHEAD TO IT RACK IN OFFICE. 11 COORDINATE EXACT EMENTS OR PLAT M MANUFACTURER TO ROUGH —IN. left LIGH , —1 O W 0 N O C L W W Lu U O O ry OL F_ m cool F_ ' O � Z w 06 LID Z o < CV m OL Z w O a� O a_ w O�00 Q z (1)a, U 0�3 F V° 6 U 75 w ry L u W W�� E � a tU 3 c 0 s tACh O M Y L o O 00 Ln Z Q �y��.�//�� W Revisions 0 0 0 0 Dore: 06122115 Ca4 9-2609 Drawn By Checked By TLH GRS Scale Date 1 /4"=1'-0" Job No. on 1.42 Cf-AI r- 1 IA"-1LfV' 2 PANEL SCHEDULES SCALE: NONE EXISTING PANEL "P4" SCHEDULE FED FROM: CIRCUIT BREAKER MOUNTING: FLUSH MOUNTED VOLTAGE: 120/208V, 3 PHASE, 4 WIRE ENCLOSURE: NEMA 1 BUS MATERIAL: EXISTING FAULT CURRENT: EXISTING BUS LOAD: 80 AMPS AIC RATING: MATCH EXISTING BUS RATING: 400 AMPS OPTIONS': BONDED EQUIPMENT GROUND BAR MAIN: MAIN LUG ONLY LOAD (VA) LOAD (VA) NOTES CKT. LOAD DESCRIPTION A B C BREAKER BREAKERI A B C LOAD DESCRIPTION CKT. NOTES 1 DISHWASHER/BAR 500Xlllll��1111,_20/1 20/1 170 ABOVE BAR TRACK 2 3 COOKLINE/LIGHTS 500 20/1 20/1 189 EXPO LIGHTING 4 5 MAIN HALL LIGHTS 500 20/1 20/1 1176 PASS. LIFT 6 7 SERVICE LIGHTS 500 20/1 20/1 800 BALLOON COMPRESSOR 8 9 YUMMM SIGN 500 20/1 20/1 500 CANLIGHTS / TV 10 11 RECPTS 500 20/1 20/1 500 CANLIGHTS SO 12 13 TIN TACKER SIGN 500 20/1 20/1 SPARE 14 15 BACKBAR REFRIG 1212 2011 20/1 200 EXIT LIGHTS/CAN 16 GFCI 17 BLENDER 636 20/1 20/1 500 NEON GRN/LIL.LIGHTS 18 GFCI 19 BAR POS 456 20/1 20/1 SPARE 20 GFC! 21 BAR PRINTER 500 20/1 20/1 500 FLOOR GREEN ?. 22 GFCI 23 DRINK MIXER 900 20/1 20/1 500 MEN BATHROOM 24 25 RECEPT 500 20/1 20/1 500 RECEPT 26 27 COFFEE MACH 1000 20/1 20/1 332 DAYLIGHTING 28 29 COFFEE MACH 1000 20/1 20/1 790 GENERAL LIGHTING 30 31 DINING LIGHTING 505 20/1 20/1 423 GATHERING/ENTRY LTG 32 33 DINING LIGHTING 765 20/1 20/1 478 GATHERING AREA LTG 34 35 DINING LIGHTING 800 20/1 20/1 520 BEER CHAND/LOUNGE TR 36 TOTALS: 2961 4477 4336 1893 2199 3986 NOTES• * SEE SPECIFICATIONS FOR OTHER OPTIONS REQUIRED BUT NOT NECESSARILY NOTED HERE GFCI CIRCUIT BREAKER SHALL BE GROUND —FAULT CIRCUIT INTERRUPTING (GFCI) TYPE N.E.C. LOAD ANALYSIS FOR EXISTING PANEL "P4" (INCLUDING SUBFEEDS) LOAD DESCRIPTION DEMAND FACTOR PHASE A (VA) PHASE B (VA) PHASE C (VA) TOTAL (VA) CONNECT. DEMAND CONNECT. DEMAND CONNECT.1 DEMAND CONNECT. DEMAND LIGHTING: 125% 2598 3248 3964 4955 4610 5763 11172 13965 RECEPTACLE: 100% 1000 1000 500 500 1000 1000 2500 2500 OTHER CONTINUOUS: 125% 456 570 500 625 0 0 956 1195 OTHER NONCONTINUOUS: 100% 1 0 0 500 500 900 900 1 1400 1400 KITCHEN: 100% 0 0 1212 1212 636 636 1848 1848 MOTOR: 100% 800 800 0 0 1176 1176 1976 1976 ADD 25% OF LARGEST MOTOR: 100% 98 98 98 98 98 98 294 294 TOTAL: 4952 5716 6774 7890 8420 9573 20146 23178 EQUIVALENT AMPS: 42 48 57 66 71 80 56 1 65 PHASE BALANCE: =27% —27% 1% 3% 26% 24% SWITCHPLATE ELEVATION SCHEDULE SWITCH LOAD CONTROLLED DESCRIPTION a P4-28 PARTIAL PRIMARY DAY LIGHTING b P4-28 PARTIAL SECONDARY DAY LIGHTING C P4-30 PARTIAL GENERAL LIGHTING d P4-30 PARTIAL GENERAL LIGHTING e P4-32 PARTIAL GATHERING AREA LIGHTING f P4-32 PARTIAL ENTRY ART LIGHTING 9 P4-34 PARTIAL GATHERING AREA LIGHTING h P4-34 PARTIAL GATHERING AREA LIGHTING i P4-36 PARTIAL LOUNGE TRACK LIGHTING P4-36 (PARTIAL)BEER CHANDELIER k P4-31 PARTIAL DINING LIGHTING I P4-31 PARTIAL DINING LIGHTING m P4-33 PARTIAL DINING LIGHTING n P4-33 PARTIAL DINING LIGHTING 0 P4-35 PARTIAL DINING LIGHTING P4-35 PARTIAL DINING LIGHTING p4-2 ABOVE BAR TRACK LIGHTING r P4-4 EXPO LIGHTING WATTSTOPPER HDA-703 (TYPICAL) (a) (b) e e . 0 0 0 e *GENERAL CONTRACTOR TO LABEL THE SWITCHPLATE (C) (d) (e) W (9) (h) (I) 0 1 0 0 0 0 0 0 0 a 9 a 0 u 0 0 0 0 0 0 0 0) (k) (1) (m) (n) (0) (P) (q) (r) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 LIGHT SWITCH COVERS PROVIDED BY CONTRACTOR PAD MOUNT TRANSFORMERv REVIEWED FOR CQ'NFMA 70C �E�TH SEP 18 2015 j City OtA U�nla -- I RECEIVED CITY OF TUKWILA SEP 0 12015 PERMIT CENTER Q 0 O 0 a) Lu � C W C 0 ~ 0 < ,.,_, 0 CL m z 1 Q V) Lu w LO 0 r 0 n N m = Z w V) CF) cV J w Z Z ' 0 Q W �00 z U a Q 0 U W c° F Luo w W ��� W IL © O V C U � � q S c L u to co O M Y O oo a3i Z Ln C 00 Revisions u.�i' 0 A A SOY SC, O L� . � wed .. ►t•.' Daly 06122115 COA #'2609 Drawn By Checked By ANH GRS Scale Date NONE Job No. 14 5 3 SWITCH BANK DETAIL 1 ELECTRICAL RISER DIAGRAM SCAT F• NONF SCALE- NONE