Permit EL15-0803 - CHEVRON GAS STATION - ELECTRICAL FOR REMODEL
CHEVRON STATION 220 STRANDER BLVD EL15-0803 City of Tukwila (DPhone: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 2623049104 Permit Number: EL15-0803 Address: 220 STRANDER BLVD Issue Date: 10/2/2015 Permit Expires On: 3/30/2016 Project Name: CHEVRON STATION Owner: Name: JAMBO TEJ L L C+MARAKA INC Address: 5727 128TH ST SW, MUKILTEO, WA, 98275 Contact Person: Name: MIKE MOULTINE Phone: (360) 459-0575 Address: PO BOX 3855, LACEY, WA, 98509 Contractor: Name: ALLIED ELECTRIC SERVICE INC Phone: (360) 459-0575 Address: PO BOX 3855, LACEY, WA, 98509 License No: ALLIEES145BC Expiration Date: 1/31/2016 Lender: Name: Address: DESCRIPTION OF WORK: ELECTRICAL FOR REMODEL Valuation of single family: $0.00 Fees Collected: $1,608.30 Valuation of mf/comm: $69,999.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: �`w Date: `7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:_L ^ ' Date: Print Name: k1 M%t'J/ 1 ice' s A 3' /� r 5 /`1DE"AiT This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department ' Permit Center �``' • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httn: wu w.Tukwila1A'A.gov SITE LOCATION Site Tenant N Electrical Permit No. G �l S — D 03 Project No.1 t ` Date Application Accepted: " — (S L J� Date Application Expires: 3- I J - use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" 4/✓d PROPERTY OWNER Name: J-R M g o Tr=�- L L C- Address: 2 3 3 130 S r SF t S (it Tle 10 City: 9V'F- Ir—TT !State: W Zip: CONTACT PERSON — person receiving all project communication Name: 471G /ijad/�%1e Address: Ad. Sax 38SS City: �� State: 4M Zip: %So9 Phone: 9- s?s Fax: v�6• yrS O SIG Email: 11 Mike co Q�I�P.e{G�te�Tlt. Valuation of Project (contractor's bid price): $ 6Q 999 Scope of Work (please provide detailed information): /�r&ryOw 'emedel Will service be altered? (2 Yes ❑ No King Co Assessor's Tax No.: 2. b 2-30 4- 91 C �F Suite Number: Floor: / C� New Tenant: ❑ .....Yes Q ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: 141l d Fl +i1C Address: pa &X a'85S City: State: w' Zip: qAf 9 Phone: yes dS,fS Fax. .7e„4 Contr Reg No.: l�LL�EES�{�5 „ Exp Date: Tukwila Business License No.; 4X Type of Use: Tyne of work: ❑ New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: 9 Puget Sound Energy ❑ Seattle City Light }i;tppplicatiom\Forms-Applications On Line\7014 ApplicationvSmtrical Permit Application Revised 1-1-14.docx Reldsed: lanuary 2014 rob Adding more than 50 amps? [✓]� Remodel ❑ Telecommunication Yes ❑ No ❑ Tenant Improvement ❑ Temporary Service Page I of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings...................................$152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ S59-85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... S81.90 (no added/altered circuits) ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ...........$54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits)...............................................$7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems.................................................$59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals....................................................................$80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ""EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE:-** PERMIT APPLICATION NOTES - j Value of Construetion — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 7191S Print Name: �aV'a R `�t8'2�Q> Day Telephone: - -Vd- "16 e • 04'7.5r Mailing Address: �o &X 38SS� zww kf *5164 City State Zip HAApplicatiom\Forms-Applications On Line12014 Applications\Elvtrical P`miit Application. Revised 1-1-14.docx Revised: January• 2014 bh Page 2 of 2 A - DESCRIPTIONS PermitTRAK ACCOUNTQUANTITY PAID $1,299.01 EL15-0803 Address: 220 STRANDER BLVD Apn: 2623049104 $1,299.01 ELECTRICAL $1,237.15 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,237.15 TECHNOLOGY FEE $61.86 TECHNOLOGY FEE TOTALR6242 R000.322.900.04.00 0.00 $61.86 $1,299.01 Date Paid: Wednesday, September 23, 2015 Paid By: KIRAN ASHER Pay Method: CREDIT CARD 03626D Printed: Wednesday, September 23, 2015 2:01 1 of 1 SYSTEMS PM DESCRIPTIONS PermitTRAK 1 $368.94 EL15-0803 Address: 220 STRANDER BLVD Apn: 2623049104 $309.29 ELECTRICAL $309.29 PLAN CHECK FEE R000.345.832.00.00 0.00 $309.29 PG15-0110 Address: 220 STRANDER BLVD Apn: 2623049104 $59.65 PLUMBING $59.65 PLAN CHECK FEE R000.322.103.00.00 0.00 $59.65 TOTAL FEES PAID BY RECEIPT: R6164 $368.94 Date Paid: Tuesday, September 15, 2015 Paid By: KIRAN ABSHER Pay Method: CREDIT CARD 04708D Printed: Tuesday, September 15, 2015 1:29 PM 1 of 1 RWSYSTEMS L \� —] INSPECTION RECORD Retain a copy with permit' 0 PERMIT N0. CITY OF TUKWILA BUILDING 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 DIVISION (206) 431-3670 . V Project: � � Type of inspection: Address: ! J ID �.*� Date Called: Special Instructions: Date Wanted: ` a. G �y p.m. Requester: Phone No: 4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: / / Date: ®f a & !�%C �i'Il�l El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �f INSPECTION RECORD ` Retain a copy with permit �y0 INSPECTION NO. PERMIT N . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �t M Type of Inspection: ^ Address: ��' ^ . /� Date Called: Special Instructions: Date Wanted.-717 a. p.m.. Requester: Phone No: Approved per applicable codes. t_J Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD G- Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � Type of Inspection: Address: y� `f �i Date Called: Special Instructions: Date Wanted: / '7 a. !� p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. IInspector: `" / IDate: f 3 /I 5— REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 60yv) INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: Date Called' Special Instructions: Date Wanted: / l© a. p.m. Requester: Phone No: 9Approved per applicable codes. LJ Corrections required prior to approval. MENTS: (Inspector: 1--:hli-W _ IDate: latOlt REINSPECTIO14FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD I fi't �Oeo Retain a copy with permit INSPE TION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 64t_ / Type of Inspection: r Address: F � Date Called: Special Instructions: Date Wanted: a. p.m. Requester: Phone No: LJ Corrections required prior to approval. t� paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit5�'� INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 fe, A.14 19V Project: 6* Type of Inspection: Address: 220 Date Called: Special Instructions: Date Wanted: f a.m. p.m. Requester: Phone No: Approved per applicable codes. "Corrections required prior to approval. COMMENTS: CA PA -CA F 41 ' nl, � V >� , f Z-C �l cJ � ,lktr� ut /XLriLVIACi ,inspector: � _ n Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. INSPECTION RECORD 2 Retain a copy with permit �® INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of inspect' % Address: // C' Date Called: Special Instructions: Date Wanted: ,a a__ l� p. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: _ s� �If 0 LOJ Address: / Date Called: Special Instructions: Date Wanted: a. p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0803 DATE: 09/15/15 PROJECT NAME: CHEVRON STATION SITE ADDRESS: 220 STRANDER BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: �,� hK 0 �2� Building Division It Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator 19 PRELIMINARY REVIEW: DATE: 09/17/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/15/15 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 ALLIED ELECTRIC SERVICE INC Page 1 of 2 Home lnicio en Espanol Coutect. Safety Washington State Department of Labor & industries Search L&I^� A-% Index Help My Secure L&I Claims & Insurance Workplace Rights Trades & Licensing I ALLIED ELECTRIC SERVICE INC I Owner or tradesperson PO BOX 3855 LACEY, WA98509 Principals 360-459-0575 ELWIN, John, AGENT THURSTON County ELWIN, H JOHN, MEMBER Doing business as ALLIED ELECTRIC SERVICE INC WA UBI No. Business type 600 599 707 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ........................................................... Meets current requirements. License specialties GENERAL License no. ALLIEES145BC Effective — expiration 01/03/1986— 01/31/2016 Designated administrator ELWIN, H JOHN License type Master Electrician Bond ................. CBIC Bond account no. SB2616 Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Active. Meets current requirements. License no. ELWINHJ9741_4 $4,000.00 Effective date 12/28/1997 Expiration date Until Canceled Workers' comp I Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 485,426-00 ................................ Doing business as ALLIED ELECTRIC SERVICE INC https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=600599707&LIC=ALLIEES 145BC&SAW= 10/02/2015 POWER DEVICES PANELBOARD - FLUSH MOUNTED SWITCHING SINGLE POLE .... PANELBOARD - SURFACE MOUNTED $ 3 THREEWAY a250 LOW VOLTAGE TRANSFORMER $ 4 FOURWAY T 250 _*`-(WATTAGE PER CIRCUIT) $ D DIMMER ® FLOORBOX WITH DUPLEX RECEPTACLE /& MOTOR CONNECTION. (NUMBER = HORSEPOWER) D DISCONNECT SWITCH DISCONNECT SWITCH - FUSED EP . COMBINATION STARTER/DISCONNECT ® MAGNETIC STARTER EQUIPMENT CONNECTION ® SPECIAL RECEPTACLE DEDICATED RECEPTACLE @ DUPLEX RECEPTACLE @ QUADRAPLEX RECEPTACLE El PUSHBUTTON ESO (EMERGENCY SHUT-OFF) 0) JUNCTION BOX $ T TIMER $ o SWITCHED OCCUPANCY SENSOR $ 03 SWITCHED 3-WAY OCC. SENSOR $Q,b,c (a,b,c) DENOTES SWITCH LEGS OS CEILING MOUNTED OCCUPANCY SENSOR LIGHTING FIXTURES SEE CEILING PLAN, SHEET E4.0 FOR LIGHT FIXTURE SCHEDULE AND SYMBOLS ELECTRICAL GENERAL NOTES: 1. ALL RECEPTACLES AND SWITCHES SHALL BE FLUSH MOUNTED FOR ALL AREAS. U.O.N. 2. THE ELECTRICAL DRAWINGS ARE GENERALLY DIAGRAMMATIC. THE ELECTRICAL INSTALLATION SHALL BE COORDINATED WITH ALL OTHER TRADES SO THAT INTERFERENCES BETWEEN THE ELECTRICAL INSTALLATION AND ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION AND EQUIPMENT INSTALLATION WILL BE AVOIDED. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS; ROOM AND AREA FINISHES, CEILING PLANS, DOOR SWINGS, FIRE RELATED PARTITIONS, CABINET AND CASE WORK AND BUILT-IN DETAILS. 4. ALL WIRING TO BE SIZE #12 AWG UNLESS NOTED OTHERWISE. 5. CONTRACTOR SHALL PROVIDE ALL DISCONNECTS TO MEET LOCAL CODES. 6. CONTRACTOR SHALL VERIFY ALL DOOR SWINGS BEFORE INSTALLING LIGHT SWITCHES. ALL LIGHT SWITCHES TO BE INSTALLED ON STRIKE SIDE OF DOOR UNLESS SPECIFICALLY NOTED OTHERWISE. 7. ALL FINAL CONNECTIONS SHOWN ON THE DRAWINGS ARE ACTUAL REQUIREMENTS OF THE EQUIPMENT AND ARE SHOWN IN THEIR APPROXIMATE LOCATION. 8. ALL MOTOR STARTERS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR FURNISHING THE EQUIPMENT AND INSTALLED, WIRED AND CONNECTED BY ELECTRICAL CONTRACTOR. 9. WHEN REQUIRED ALL AUDIO/VISUAL INDICATORS SHALL BE INSTALLED ABOVE THE FIRE ALARM PULL STATION AT APPROXIMATELY 6" BELOW CEILING OR +80" A.F.F. WHICHEVER IS LOWER. 10. ALL BATTERY BACKUP, EMERGENCY LIGHTING FIXTURES SHALL BE CONNECTED TO THE SAME CIRCUIT SERVING LIGHTING IN THAT AREA PRIOR TO ANY SWITCHING. 11. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHERPROOF AND RAIN TIGHT. 12. COORDINATE ALL LIGHTING WITH MECHANICAL AND PLUMBING EQUIPMENT. 13. CONTRACTOR TO VERIFY THAT EQUIPMENT WITH CIRCUIT BREAKERS AS LOCAL DISCONNECT MEANS IS HACR RATED. IF NOT, PROVIDE DISCONNECT SWITCH PER N.E.C. 14. MOUNTING HEIGHT OF ALL DEVICES SHALL CONFORM WITH 2O08 N.E.C., STATE ELECTRICAL CODE, LOCAL CODES AND ADA. UNLESS OTHERWISE INDICATED ON THE DRAWINGS. - RECEPTACLES: 15"; 48" AFF TO CL - SWITCHES: 48" AFF TO CL f�= 6W!tl_�'� �--� HOMERUN TO PANEL P1-5 (INDICATES PANEL AND CIRCUIT NUMBER) CONDUIT #10 "'~(WIRE GAUGE OTHER THAN AWG#12) - - - UNDERGROUND CONDUIT TELEPHONE -DATA 41 DATA OUTLET - (2) DATA - CAT 5e (2) VOICE - CAT 5e TELEPHONE OUTLET k ' PAINTED 3/4" PLYWOOD BACKBOARD AC AIR CONDITIONING AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT A AMPERE AWG AMERICAN WIRE GAUGE BLDG BUILDING BKBD BACKBOARD BKR BREAKER CAB CABINET C CONDUIT CB CIRCUIT BREAKER CKT CIRCUIT CCTV CLOSED CIRCUIT TELEVISION CO CONDUIT ONLY CT CURRENT TRANSFORMER DIST DISTRIBUTION (E) EXISTING EC ELECTRICAL CONTRACTOR EF EXHAUST FAN EGC EQUIPMENT GROUNDING CONDUCTOR ENCL ENCLOSURE ESO EMERGENCY SHUT-OFF SWITCH EWC ELECTRIC WATER COOLER F/A FIRE ALARM FBO FURNISHED BY OWNER FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR F FUSE GFI GROUND FAULT INTERRUPTER HTR HEATER IG ISOLATED GROUND J-BOX JUNCTION BOX LTG LIGHTING MTD MOUNTED M METER NIC NOT IN CONTRACT MLO MAIN LUGS ONLY (N) NEW 15. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF FIRE RATED ASSEMBLY DESIGN NUMBERS. COORDINATE ALL DESIGN WORK WITH FIRE RESISTANCE OF MATERIALS AND CONSTRUCTON. 16. ELECTRICAL SYSTEM EQUIPMENT AND COMPONENTS SHALL BE U.L LISTED, AND BE IN COMPLIANCE WITH THE REGULATIONS OF THE STATE AND LOCAL ENFORCING AGENCIES. 17. THE ELECTRICAL CONTRACTOR SHALL REFER TO AND COORDINATE THE LOCATION OF ALL AREA/OCCUPANCY SEPARATION WALLS WITH THE ARCHITECTURAL DRAWINGS AND DETAILS. 18. ALL CONDUIT, ETC. PENETRATIONS THROUGH THE BUILDING SHALL BE FIRE/SMOKE STOPPED PER THE LATEST EDITION OF THE UNDERWRITERS LABORATORIES FIRE RESISTANCE WITH HOURLY RATINGS FOR THROUGH -PENETRATION FIRE STOPS SYSTEM VOLUME #2 OR SHALL BE INSTALLED IN STRICT ACCORDANCE PER THE MANUFACTURERS U.L. LISTINGS (3M-OR EQUAL). COORDINATE WITH GENERAL CONTRACTOR PRIOR TO BIDDING. 19. ALL ELECTRICAL WORK SHALL CONFORM TO U.L. STANDARDS, 2008 N.E.C., N.F.P.A. AND ALL OTHER CODES OF JURISDICTION WHICH ARE APPLICABLE TO THIS ELECTRICAL INSTALLATION. 20. WHERE REMODELING/DEMO WORK DISRUPTS CONTINUITY OF EKISTING CONDUITS OR CIRCUITS, PROVIDE CON DUIT/WI RE/J-BOXES, ETC TO MAINTAIN CONTINUITY. 21. ALL ELECTRICAL GROUNDING SYSTEMS WILL NEED TO BE APPROVED BY THE ELECTRICAL INSPECTOR PRIOR TO INSTALLATION. 22. E.C. TO ENSURE COMPLIANCE OF ASCE7-10, SECTION 13.6; PROPER SEISMIC SUPPORT AS IT PERTAINS TO THE INSTALLATION OF CONDUIT, PANELS, FIXTURES, ETC. CONTRACTOR IS TO BRING UP ANY DISCREPANCIES AND ITEMS WHICH ARE NOT SPECIFICALLY CALLED FOR OR SHOWN, BUT ARE REQUIRED FOR A COMPLETE ELECTRICAL SYSTEM, AND WHICH AFFECT HIS CONTRACT PRIOR TO ENTERING AND SIGNING THE CONTRACT. AFTER AWARDING THE CONTRACT, ALL SUCH ITEMS REQUIRED FOR A COMPLETE SYSTEM READY FOR THE OWNER'S BENEFICIAL USE SHALL BE FURNISHED AND INSTALLED INCLUDING ALL SUCH AFOREMENTIONED DISCREPANCY ITEMS AT NO ADDITIONAL COST TO THE OWNER. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO DETERMINE THE EXACT IMPACT OF THE RETROFIT TO THE ELECTRICAL SYSTEM AND SHALL INCLUDE IN HIS BID ALL THE WORK WHICH MIGHT NOT BE SPECIFICALLY MENTIONED BUT ARE REQUIRED FOR A COMPLETE ELECTRICAL SYSTEM READY FOR OWNER'S BENEFICIAL USE. OHL OVERHEAD LINE OL OVERLOAD PNL PANEL P POLE REC RECEPTACLE RGS RIGID GALVANIZED STEEL SCH SCHEDULE SMR SURFACE METAL RACEWAY SW SWITCH SWBD SWITCHBOARD TEL TELEPHONE TYP TYPICAL TV TELEVISION UON UNLESS OTHERWISE NOTED UG UNDERGROUND W WATT WH WATT HOUR METER WP WEATHERPROOF XMFR TRANSFORMER V VOLT Y WYE REVISIONS No changes shall be made to the scope of work without prior approval of Tul(wila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. I SEPARATE PEA 11T REQUIRED FOR: J6 wohnnical d Electti cw 0 Plumbing iff Gas Piping City of Tukwila BU1L01NG DIVISION PLAN INDEX: E1.0 GENERAL NOTES, SYMBOLS, AND PLAN INDEX E1.1 ELECTRICAL SITE PLAN E2.0 FLOOR PLAN - LIGHTING E3.0 FLOOR PLAN - POWER E3.1 POWER EQUIPMENT SCHEDULE/NOTES E5.0 POWER RISER DIAGRAM AND GROUNDING DETAIL E6.0 PANEL SCHEDULES E7.0 ENERGY CODE FORMS E7.1 ENERGY CODE FORMS E8.0 ELECTRICAL SPECIFICATIONS FILE COP eat No. 6Vl • �� Mo review r.�proval is subject to errors and omissions. Approval Pf : ,nstruction documents does not authorize 10 to violation 6. any adopted code or ordinance. Rewipt of ved Field Copy and conditions is acknovAe (RECEIVED By: CITY OF TUKWit.A Date: _00,1- 2 S SEP 15 2015 City of Tukwila PERPAIT CENTER BUILDING DIVISION �Z A 0 c2ZI�o Seal f'r° Ze t zd 3 t h)P ABOSSEIN ENGINEERING L.L.C. MECHANICAL I ELECTRICAL I CIVIL LEER I FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PHONE: (425) 462-9441 W o' J W a� ;Z M � Q D >_ W � D w f I m cn Of Z g Z zi a � Z F- g UJ J W W _ W d d U m °M O W 'Q Z (n U) .Q Z U) 0 U Z 0 0 Z o a a o J W W W D J J M = S m W W I 0 Lo LO LO ~ \ LO to �`� \ N _N \ \ \ \ \ \ \ Q CODE COM144ANCE APPROVED SEP 3 0 2015 _ JV) K Sheet Name GENERAL NOTES, SYMBOLS, .PLAN INDEX Sheet Number E IA 0 ■ M 1 1 Z7 V/1 I L1V1 1 1 1—L/I141—'— FL 0 OR PLAN - LIGHTING � SCALE: 1/4" = 1'-0" NORTH LUMINAIRE SCHEDULE CALLOUT SYMBOL LAMP DESCRIPTION BALLAST MOUNTING MODEL INPUT WATTS VOLTS LOCATION QUANTITY L1 (3) 32W T8 2' x 4' RECESSED (PARABOLIC) FLUOR. LIGHT FIXTURE ELECTRONIC RECESSED 96 120V 1 P 2W RETAIL AREA 30 L2 (1) 13W LED SURFACE —MOUNTED COOLER LIGHT LOCATED BY COOLER MANUFACTURER ELECTRONIC SURFACE 13 120V 1P 2W WALK IN COOLER 6 L3 (1) 32W T8 10" x 4' RECESSED WALL WASH LIGHT ELECTRONIC RECESSED 32 120V 1 P 2W BATHROOM ENTRANCE, COOLER DISPLAY 11 L4 (2) MR16 TWIN HEAD DISPLAY LIGHT "DUETTO" ELECTRONIC SURFACE 50 120V 1 P 2W HYDRAZONE DISPLAY 1 L5 (2) 32W T8 10" x 4' STRIP FLUOR. ELECTRONIC CEILING 64 120V 1P 2W OFFICE, STORAGE, BATHROOMS 10 ELECTRONIC L6 0 (1) LED SURFACE MOUNT 6" DOWNLIGHT ELECTRONIC SURFACE 13 120V 1P 2W STORAGE CLOSET 1 X1 (1) LED CEILING MOUNTED EXIT SIGN ELECTRONIC CEILING 120V 1 P 2W MAIN ENTRANCES 2 Z1 (2) 32W T8 WET RATED T8 WRAP ELECTRONIC CEILING 64 120V 1P 2W EXTERIOR SOFFIT LIGHTING 16 -1 1 .1 SWITCHING SCHEME: —LIGHT SWITCHES LOCATED IN CASHIER AREA. —SWITCH GROUPS 'a' AND V WILL CONTROL ALL GENERAL LIGHTING IN SALES AREA. —SWITCH GROUPS V THROUGH 'e' WILL CONTROL ALL OTHER LIGHT FIXTURES. —DAYLIGHT ZONES TO BE CONTROLLED BY PHOTOCELLS LOCATED ADJACENT TO FRONT WINDOWS. —LUMINARIES MARKED WITH V OR 'j SHALL BE CONTROLLED BY PHOTOCELL ACCORDING TO PRIMARY DAYLIGHT ZONE. —LUMINARIES MARKED WITH 'x' OR Y SHALL BE CONTROLLED BY PHOTOCELL ACCORDING TO SECONDARY DAYLIGHT ZONE. FLAG NOTES: ALL EXIT LIGHTING FIXTURES TO BE CONNECTED TO LOCAL LIGHTING CIRCUIT, AHEAD OF ANY AND ALL SWITCHING. FIELD VERIFY SWITCH BANK LOCATION WITH STORE MANAGER. USE LOCAL LIGHTING CIRCUIT FOR EXHAUST FAN. FAN TO RUN WHILE LIGHTS ARE IN USE. EXHAUST FAN TO BE CONNECTED TO OCCUPANCY SENSOR. INSTALL SWITCH AND LIGHTS AS SHOWN. PROVIDE SEALANT AT ALL CONDUIT PENETRATIONS INTO COOLER TO PREVENT CONDENSATION. LIGHT FIXTURES SHALL BE 40 LUMENS PER WATT OR HIGHER PER WSEC C405.10. j PROVIDE DUAL TECHNOLOGY MULTI —WAY WALL SWITCH SENSOR. WATTSTOPPER DW-103 OR EQUAL. B�> CONNECT EMERGENCY PATHWAY LIGHTS TO LOCAL LIGHTING CIRCUIT AHEAD OF ALL SWITCHES. PATHWAY ILLUMINATION SHALL COMPLY WITH NFPA 101 OF 1 FC AVERAGE ALONG THE REQUIRED PATH OF EGRESS. MOUNT NORTHEAST AND ABOVE SOFFIT LINE AND PER MANUFACTURER INSTALLATION INSTRUCTIONS. PHOTOCELL TO BE USED TO CONTROL 'Cl' EXTERIOR SOFFIT LIGHT FIXTURES. SWITCH TO CONTROL 'Cl' EXTERIOR SOFFIT LIGHT FIXTURES. PATH OF EGRESS. 10 RESTROOM LIGHTING TO REMAIN AS IS. CEILING MOUNTED OCCUPANCY SENSOR SHALL BE PROVIDED. P�>ELECTRICAL AND STORAGE ROOM LIGHTING TO REMAIN AS IS. REPAIR LIGHTING AND CLEAN FIXTURES AS NEEDED. ROOM CONTROLLER LMRC-102 Neutral Wht 1 ( Iulolulolulo 120/230/277 DLM Occupancy Sensor (OPTIONAL) SEE INSTALLATION I RJ45 INSTRUCTIONS FOR (Typical) TERMINATION TYPE. Red Lighting Load (a) Yel Lighting Load (b) LMLS-105 On/Off Photosensor with LMRC-102 Room Controller SEE INSTALLATION INSTRUCTIONS FOR TERMINATION TYPE. LMRJ SERIES PRE —TERMINATED �_ CABLES OR CAT5E. FREE TOPOLOGY & SPUTTER ACCEPTABLE DLM Wall Switch LMSW—Series (As Needed) LM LS-105 On/Off Photosensor' RECEIVED CITY OF TUKWILA SEP 15 2015 lo771P110T CENTER NOTE: ELECTRICAL CONTRACTOR TO PROVIDE, INSTALL AND COMMISSION LIGHTING CONTROLS NOTED IN DETAIL (OR SIMILAR) AS REQUIRED. DEVICES ARE PRESET FOR PLUG n' GOB OPERATION, ADJUSTMENT IS OPTIONAL. SEQUENCE OF OPERATION: WHEN AMBIENT LIGHT LEVELS EXCEED THE OFF SETPOINT, THE LMLS-105 TURNS LIGHTING LOAD (A) OFF. IT WILL TURN CONNECTED LIGHTING LOAD (A) BACK ON WHEN THE ON SETPOINT IS TRIGGERED. FOR FULL OPERATIONAL DETAILS, ADJUSTMENTS AND MORE FEATURES OF THE PRODUCT, SEE THE DLM SYSTEM INSTALLATION GUIDE AT WWW.WATTSTOPPER.COM 19401 40th Ave. West, Suite 300 Lynnwood, Wa. 98036 Ph. (425) 405-7746 e-mail: dwallace@PMDGinc.com Kenneth McCracken, Architect u Seal ABOSSEIN ENGINEERING L. L.C. MECHANICAL I ELECTRICAL I CIVIL LEED I FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PHONE: (425) 462-9441 W W w E— � ¢ J Cl- J >- W W I m � cn W W O Z J r Z wLLj I-- i- J � 0- W V) _ :2 m W :2 M W W CL CL ('0� W ov °- c� J ¢ 0 J ¢ 0 z ¢ 0 o _j Q¢ _j Z o w w —I M W M W = W = M m _I W —I W Q 0 LO \ N \ M N\ .— N \ \ t'7 \ 10 .— \ N r-- \ N V) d' L0 CO r- O) o' Q y . a SEP 3 0 2015 Sheet Name FLOOR PLAN LIGHTING PHOTOSENSOR WITH ROOM CONTROLLER DETAIL (TYPICAL) SCALE: NONE Sheet Number MAIN BREAKER INTERLOCK FOR — FUTURE GENERATOR NEW CT ENCLOSURE r--------- r i i i i FLAG NOTES: �. NOT USED. PROVIDE WEATHERPROOF DISCONNECT SWITCH FOR EVAPORATOR COIL. COORDINATE EXACT LOCATION AND INSTALLATION REQUIREMENTS BY MANUFACTURER. EVAP COIL TO BE HUNG 1 FOOT FROM BACK WALL. PROVIDE ALL WALK-IN COOLER/FREEZER POWER CONNECTIONS INCLUDING; DOOR HEATERS, DEFROST TIMER CONTROLS, D�> EVAPORATORS AND LIGHTING AS REQUIRED. ALL PENETRATIONS SHALL BE SEALED WITH APPROVED SEALANT TO PREVENT CONDENSATION DUE TO TEMPERATURE DIFFERENCES. FIELD COORDINATE CONDENSER LOCATIONS FOR WALK-IN COOLERS, FREEZER, AND OPEN DISPLAY CASES. PROVIDE WIRING AS REQUIRED BY MANUFACTURER. PROVIDE A MOMENTARY PUSH BUTTON SWITCH NEAR OUTSIDE 5 LIGHTING OVERRIDE SWITCH WITHIN CABINET TO ALERT CO-WORKERS IN THE BACKROOM OR WALK-IN COOLERS. FIELD VERIFY EXACT LOCATION. PROVIDE AND INSTALL ESO SWITCH. INCLUDE ALL ASSOCIATED CONDUIT AND WIRE FOR COMPLETE INSTALLATION PER NEC 514.11 AND NFPA 30A SECTION 6.7. COORDINATE EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. PROVIDE (2) J" SCH PVC CONDUIT FOR POWER AND (1)" SCH 40 CONDUIT FOR TELEPHONE/DATA CASHIER COUNTER. DESIGNATED AREA FOR FUEL EQUIPMENT & CONTROLS. (VERDE PORT SYSTEM - DISPFNSER CONTROLS) WATER HEATER TO SERVE EXISTING LAYS, NEW MOP SINK, NEW 3 COMP SINK. 10 NOT USED. 11 ELECTRICAL CONTRACTOR SHALL RELOCATE ALL EXISTING FUEL DISPENSER CONTROL EQUIPMENT TO NEW LOCATION. SHEET NOTES: 1. REFER TO SHEET E3.1 FOR RETAIL EQUIPMENT INFORMATION. 2. ALL FOOD AND BEVERAGE RECEPTACLES TO BE LOCATED UNDEF COUNTER. MOUNT AT 18"-24" AFF TO AVOID SHELVING, CONFIRM IN FIELD. 3. RECEPTACLES LOCATED IN CASHIER CABINET TO BE MOUNTED AT 12" AFF. AVOID SHELVING AND VERIFY EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. 4. ROUTE ALL COMMUNICATION TO D—MARK. COORDINATE LOCATION WITH UTILITY PROVIDER. 5, ALL 120V 20A OUTLETS THAT SERVICE FOOD & BEVERAGE SHALL BE GFCI PROTECTED PER NEC 210.8(B)(2). CONDENSING UNIT FLOOR PLAN —POWER � SCALE: 1/4" = 1'-0" FRONT END COOLER NOVELTY ICE CREAM MERCHANDISER FILTER Flagg g: . ITS II ;1" RE CODE C ' ASP SEP city BUILDII RECEIVED CITY OF TU ML P, dy Architects 19401 40th Ave. West, Suite 300 Lynnwood, Wa. 98036 Ph. (425) 405-7746 e-mail: dwallace@PMDGinc.com Kenneth McCracken, Architect ABOSSEIN ENGINEERING L. L.C. MECHANICAL I ELECTRICAL I CML LEED I FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PHONE: (425) 462-9441 W H J Q W � Q J CY D M D W Z I m (n Ix O Z_ J (n (= F- I- N •�` Z F— W Q. d 0- (n m M2 W i= Q Q z W Z Z Q 0 O J Q J Q a W W J W W W D J J M M_= m W W LU r to LO LO LO LO LO Q p 0 N N .- ►'� N \ N \ M .- N - \ \ \ \ \ \ \ N n d- o o n M Ew<i z C 0 C• ti ezK nr �{ in ro iJ$ J 03 $, <" 1'cm • 1 r N. 0 2015 Project Number 215042 Sheet Name FLOOR PLAN POWER SEP 15 2015 Sheet Number SECTION 16000 -ELECTRICAL SPECIFICATIONS GENERAL 1. GENERAL CONDITIONS: THE GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS AND SPECIAL CONDITIONS ARE A PART OF THIS CONTRACT AND APPLY TO THIS SECTION AS FULLY AS IF REPEATED HEREIN. A. THIS SECTION OF SPECIFICATIONS INCLUDES, BUT IS NOT LIMITED TO: B. ALL LABOR, TOOLS, APPLIANCES, MATERIALS AND EQUIPMENT REQUIRED TO FURNISH AND INSTALL THE COMPLETE INSTALLATION SHOWN ON THE DRAWINGS FOR THIS SECTION OF THE WORK AND/OR IN THE FOLLOWING SPECIFICATIONS, INCLUDING THAT WHICH IS REASONABLY INFERRED. 3. CODES AND REGULATIONS: ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH APPLICABLE REQUIREMENTS OF PUBLIC AUTHORITIES HAVING JURISDICTION AND UTILITIES FURNISHING SERVICES. CODES GOVERNING THIS WORK INCLUDE BUT ARE NOT LIMITED TO THE LATEST APPROVED EDITION OF THE FOLLOWING: -NATIONAL FIRE PROTECTION ASSOCIATION'S NATIONAL ELECTRICAL CODE (NEC). -OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA). -LOCAL ORDINANCES AND REGULATIONS. 4. STANDARDS: ELECTRICAL MATERIAL AND EQUIPMENT SHALL HAVE BEEN TESTED AND LISTED OR LABELED AS CONFORMING TO APPROVED PUBLISHED STANDARDS BY UNDERWRITERS LABORATORIES WHERE SUCH LISTING OR LABELING SERVICE IS AVAILABLE FOR THE CLASS OF MATERIALS OR EQUIPMENT. WHERE APPLICABLE, LISTING OR LABELING SHALL APPLY TO THE COMPLETE ASSEMBLED EQUIPMENT AND NOT TO THE COMPONENTS ALONE. 5. SUBMITTALS: PRODUCTS 1. PANELBOARDS: THREE COPIES OF MATERIALS LIST, SHOP DRAWINGS AND DATA SHEETS SHALL BE SUBMITTED TO ARCHITECT &/OR CONSTRUCTION MANAGER FOR REVIEW. SUBMITTALS SHALL BE MADE AND FAVORABLE REVIEW SECURED BEFORE MATERIAL AND EQUIPMENT IS INSTALLED. MATERIALS LIST SHALL INCLUDE FIXTURES, SWITCHGEAR, PANELS, DEVICES, WIREWAYS, DISCONNECTS, LAMPS AND ALL OTHER SPECIFIED OR UNSPECIFIED STANDARD CATALOGED MATERIALS TO BE USED. THE LIST SHALL INCLUDE MANUFACTURER, TYPE AND SUCH OTHER DESCRIPTIVE DATA AS MAY BE REQUIRED TO DETERMINE THE ACCEPTABILITY OF EACH ITEM. SHOP DRAWINGS AND DATA SHEETS FOR EQUIPMENT AND SYSTEMS SHALL BE SUBMITTED WHERE REQUIRED IN THE SPECIFICATION FOR THOSE ITEMS. INCLUDE INFORMATION ON EACH COMPONENT, WIRING DIAGRAMS, LAYOUTS, DIMENSIONS AND SUFFICIENT OTHER DATA TO ESTABLISH COMPLIANCE WITH THE SPECIFICATIONS AND ACCEPTABILITY OF THE EQUIPMENT OR SYSTEM. 6. PERMITS AND DRAWINGS: ELECTRICAL CONTRACTOR SHALL SUBMIT TO THE LOCAL AUTHORITY THE THE REQUIRED DOCUMENTS TO PURCHASE AND SECURE ALL NECESSARY PERMITS AND COORDINATE REQUIRED INSPECTIONS FOR APPROVAL. 7. AS -BUILT DRAWINGS: ON A SET OF CONTRACT DRAWINGS, KEPT AT THE SITE DURING CONSTRUCTION, MARK ALL WORK THAT IS INSTALLED DIFFERENTLY FROM THAT SHOWN, INCLUDING ANY REVISED CIRCUITRY, MATERIAL OR EQUIPMENT. UPON CONCLUSION OF WORK, DELIVER TO OWNER'S REP. CONSTRUCTION MANAGER A SET OF SIGNED AND DATED "AS -BUILT" DRAWINGS. 8. GUARANTEE: ALL WORK SHALL BE GUARANTEED FOR A MINIMUM PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE OWNER. THE GUARANTEE PERIOD FOR CERTAIN ITEMS SHALL BE LONGER, AS INDICATED IN THE SPECIFICATION FOR THOSE ITEMS. SHOULD ANY MALFUNCTION DEVELOP DURING THE GUARANTEE TIME PERIOD DUE TO DEFECTIVE MATERIAL, FAULTY WORKMANSHIP, OR NON-COMPLIANCE WITH PLANS, SPECIFICATIONS, CODES OR DIRECTIONS OF THE OWNER,ARCHITECT, ENGINEER OR INSPECTOR, THE CONTRACTOR SHALL FURNISH ALL NECESSARY LABOR AND MATERIALS TO CORRECT THE MALFUNCTION WITH -OUT ADDITIONAL CHARGES. A. PANELBOARDS SHALL BE FACTORY ASSEMBLED CIRCUIT BREAKER TYPE. THE NUMBER OF POLES, TYPE, VOLTAGE AND AMPERE RATINGS SHALL BE AS INDICATED ON THE DRAWINGS. BUSSING SHALL BE ALUMINUM OR COPPER (SEE PANEL SCHEDULES). B. NEUTRAL WIRES SHALL BE CONNECTED TO A COMMON NEUTRAL BUS WITH BINDING SCREWS OR LUGS. THE NEUTRAL BUS SHALL BE INSULATED FROM THE CABINET. GROUND WIRES SHALL BE CONNECTED TO A COMMON EQUIPMENT GROUND BUS WITH BINDING SCREWS OR LUGS. THE GROUND BUS SHALL BE BONDED TO THE CABINET. C. CABINETS SHALL BE FLUSH MOUNTED. CABINETS SHALL BE CONSTRUCTED OF GALVANIZED STEEL CONFORMING TO UL AND NEC STANDARDS. D. FRONTS OF CABINETS SHALL BE NOT LESS THAN 12 GAUGE STEEL FASTENED WITH SCREWS IN COUNTERSUNK WASHERS, OR WITH APPROVED CONCEALED SPRING CLAMPS. CABINET FRONTS SHALL HAVE HINGED LOCKABLE DOORS WITH MILLED KEYS (ALL PANELS SHALL BE KEYED ALIKE) AND CIRCUIT SCHEDULE HOLDERS WITH CLEAR PLASTIC WINDOWS. PROVIDE TYPEWRITTEN SCHEDULES IN HOLDERS AND SUBMIT COPIES FOR RECORD PURPOSES. DOORS SHALL BE FASTENED TO TRIM WITH FULL LENGTH FLUSH HINGES. PANEL FRONTS SHALL BE SHOP PAINTED WITH 2 COATS OF PRIMER AND A FINISH COAT OF GRAY ENAMEL. E. SPECIAL PANELBOARD CONSTRUCTION OR FEATURES SHALL BE AS SHOWN ON DRAWINGS. FOR CIRCUIT BREAKERS, CONTACTORS AND OTHER EQUIPMENT TO BE INCLUDED AS AN ASSEMBLED PART OF THE PANELBOARD, REFER TO THE PARAGRAPH WHERE THOSE ITEMS ARE SPECIFIED. F. ALL CONDUCTOR TERMINALS AND EQUIPMENT ENCLOSURES SHALL BE U.L. LISTED FOR USE WITH MINIMUM 75' C. RATED CONDUCTORS. G. PANELBOARD DIRECTORY FOR EACH PANEL SHALL BE NEATLY TYPED INDICATING ACTURAL LOAD FOR EACH BRANCH CIRCUIT. H. PROVIDE SIGNAGE FOR ALL PANELBOARDS & SWITCHBOARDS WARNING QUALIFIED PERSONS OF POTENTIAL FLASH HAZARD AS REQUIRED IN N.E.C. 110 2. CIRCUIT BREAKERS: A. CIRCUIT BREAKERS SHALL BE BY THE SAME MANUFACTURER THAT FURNISHES THE MAIN SERVICE EQUIPMENT AND PANELBOARDS. B. BREAKERS SHALL BE MOLDED CASE BOLT -ON TYPE. CLAMP -ON, PUSH -ON, OR PLUG-IN TYPES ARE NOT ACCEPTABLE REMOVABLE HANDLE TIES AND DUAL, QUAD OR TANDEM BREAKERS ARE NOT ACCEPTABLE. MOUNTING HARDWARE, ACCESSORIES, FACEPLATES AND ENCLOSURES SHALL BE PROVIDED AS NECESSARY FOR THE INTENDED USE. C. SHORT CIRCUIT INTERRUPTING CAPACITY SHALL BE AS INDICATED ON THE PLANS AND SHALL IN NO CASE BE LESS THAN 10,000 RMS SYMMETRICAL AMPS AT THE APPLIED VOLTAGE. 3. DISCONNECT SWITCHES: A. SWITCHES SHALL BE BY SQUARE-D, CUTLER HAMMER, OR EQUIVALENT. B. SWITCHES AND ENCLOSURES SHALL BE GENERAL DUTY. THEY SHALL BE EXTERNALLY OPERATED, QUICK -MAKE, BLADE TYPE, OF NUMBERS OF POLES AND RATING INDICATED OR REQUIRED. C. ENCLOSURES SHALL BE NEMA I FOR DRY, INTERIOR LOCATIONS AND NEMA 3R FOR DAMP, WET OR EXTERIOR LOCATIONS. FINISH SHALL BE ANSI 61. COVERS SHALL HAVE A DEFEATABLE INTERLOCK. OPERATING HANDLES SHALL BE PADLOCKABLE. D. SHORT CIRCUIT WITHSTAND RATINGS SHALL BE 200,000 RMS SYMMETRICAL AMPS. E. SWITCHES SHALL ACCEPT FUSES OF THE RATING AND UL OR NEMA CLASS INDICATED. F. SUBMIT DATA SHEETS OF THE DISCONNECT SWITCHES AS REQUIRED UNDER "SUBMITTALS". G. ALL CONDUCTOR TERMINALS AND EQUIPMENT ENCLOSURES SHALL BE U.L. LISTED FOR USE WITH MINIMUM 75° C. RATED CONDUCTORS. 4. MANUAL MOTOR STARTERS: A. WHERE SHOWN ON THE PLANS, FRACTIONAL HORSEPOWER MOTORS SHALL TOGGLE TYPE MANUAL STARTERS WITH THERMAL OVERLOAD PROTECTION IN EACH PHASE. WHERE THE MOTOR IS OUT OF SIGHT OF THE SWITCH PROVIDE A PILOT LIGHT IN THE COVER TO INDICATE SWITCH IS CLOSED. B. SUBMIT DATA ON STARTERS AS REQUIRED UNDER "SUBMITTALS". 5. SNAP SWITCHES: A. AC GENERAL USE SNAP SWITCHES SHALL BE TOGGLE HANDLE, QUIET OPERATING, PREMIUM OR HEAVY DUTY SPECIFICATION GRADE, UL LISTED AND VERIFIED TO MEET FEDERAL SPECIFICATION W-S-896-D AND NEMA HEAVY DUTY TESTS. COLOR SHALL BE WHITE. B. ALL SWITCHES SHALL BE RATED 120/277 VOLTS. FOR THE 20 AMP SIZE, HP RATINGS SHALL BE 1 FOR 120V AND 2 FOR 240V. C. SWITCHES SHALL BE AS LISTED BELOW: -20A SPST; HUBBELL 1221, LEVITON 1221 OR P & S 521 D. SWITCHES REQUIRED BUT NOT LISTED SHALL HAVE EQUIVALENT QUALITY AS THOSE LISTED ABOVE. 6. RECEPTACLE OUTLETS: A. RECEPTACLE OUTLETS SHALL BE STANDARD NEMA CONFIGURATION, GROUNDING TYPE. B. GENERAL CONVENIENCE OUTLETS SHALL BE 20 AMP, 125 VOLT, 2 POLE, 3 WIRE GROUNDING. OUTLETS SHALL BE UL LISTED AND VERIFIED .TO MEET FEDERAL SPECIFICATION W-C-596-C AND NEMA HEAVY DUTY PERFORMANCE TESTS. C. CONVENIENCE OUTLET FRONTS SHALL BE WHITE. COLOR SHALL BE BROWN ON WOOD PANELED WALLS. CONFIRM COLOR WITH ARCHITECT. D. OUTLETS SHALL BE AS LISTED BELOW: (NUMBERS DO NOT INCLUDE COLOR DESIGNATION OR OPTIONS). -20A CONVENIENCE: HUBBELL 5352, LEVITON 5362, OR P & S 5362 E. SPECIAL OUTLETS, NOT LISTED ABOVE, SHALL BE STANDARD NEMA CONFIGURATION FOR THE APPLICATION SHOWN AND SHALL BE OF EQUIVALENT GRADE AND QUALITY TO THOSE LISTED ABOVE. AN APPROVED CORD CAP OR PLUG SHALL BE FURNISHED WITH EACH RECEPTACLE OUTLET EXCEPT GENERAL CONVENIENCE TYPE. PLUG SHALL BE OF THE SAME GRADE, QUALITY AND MANUFACTURER AS THE OUTLET. 7. DEVICE & BOX COVER PLATES: A. PROVIDE A PLATE FOR EACH OUTLET, RECEPTACLE, SWITCH, DEVICE AND BOX. B. PLATES FOR FLUSH INTERIOR GENERAL USE SHALL BE WHITE PLASTIC. COLOR SHALL BE BROWN ON WOOD PANELED WALLS. CONFIRM PLATE COLORS WITH ARCHITECT PRIOR TO ORDERING. C. ALL PLATES FOR EXTERIOR USE SHALL BE LISTED AND LABELED "SUITABLE FOR WET LOCATION WHILE IN USE". D. GANGED DEVICES SHALL HAVE GANG PLATES EXACTLY MATCHING THE ARRANGEMENT AND QUANTITY OF DEVICES. E. SPECIAL PLATES, ENGRAVING OR APPLICATION SHALL BE AS INDICATED ON THE DRAWINGS OR OTHERWISE SPECIFIED. 8. OUTLET AND JUNCTION BOXES: A. THE SIZE OF EACH OUTLET OR JUNCTION BOX SHALL BE DETERMINED BY THE NUMBER AND SIZES OF WIRES AND CONDUITS ENTERING THE BOX, PER NEC, BUT SHALL BE NOT LESS THAN 4-INCH SQUARE AND 1-1/2 INCHES DEEP UNLESS OTHERWISE NOTED. B. OUTLET AND JUNCTION BOXES FOR INTERIOR USE SHALL BE GALVANIZED, ONE-PIECE PRESSED OR WELDED STEEL, KNOCKOUT TYPE, EXCEPT WHERE OTHER TYPES OF BOXES ARE INDICATED OR SPECIFIED. IN MASONRY OR CONCRETE CONSTRUCTION WATERPROOF BOXES MANUFACTURED FOR THAT PURPOSE SHALL BE USED. PLASTIC, FIBER OR COMPOSITION BOXES WILL NOT BE PERMITTED. C. OUTLET AND JUNCTION BOXES FOR SURFACE EXTERIOR USE SHALL BE CAST BOXES, CROUSE-HINDS FS TYPE, OR APPROVED EQUIVALENT. 9. CONDUITS AND FITTINGS: A. STANDARD WEIGHT RIGID METAL CONDUIT SHALL BE HOT DIPPED GALVANIZED, ALL FITTINGS SHALL BE OF THE SCREW THREAD TYPE. COUPLINGS, LOCKNUTS, BUSHINGS, ETC., SHALL BE HOT DIPPED GALVANIZED. B. ELECTRICAL METALLIC TUBING (EMT) SHALL BE GALVANIZED. COUPLINGS AND CONNECTORS SHALL BE GALVANIZED. FITTINGS SHALL BE COMPRESSION TYPE WITH GLAND SEALING RINGS OR SET SCREW TYPE. C. FLEXIBLE CONDUIT SHALL BE GALVANIZED STEEL OR ALUMINUM. WHERE USED IN DAMP OR WET LOCATIONS FLEXIBLE CONDUIT SHALL BE OF THE LIQUID -TIGHT TYPE WITH OUTER NEOPRENE JACKET AND SUITABLE LIQUID -TIGHT FITTINGS. D. RIGID NON-METALLIC CONDUIT SHALL BE PVC SCHEDULE 40, U.L. APPROVED. ALL COUPLINGS, FITTINGS, SOLVENT CEMENT, ETC.. 10. WIRE AND CABLE: A. WIRE AND CABLE FOR USE ON SYSTEMS OF 50 VOLTS TO 600 VOLTS SHALL BE 600 VOLT RATED TYPE THW OR THHN FOR BRANCH CIRCUITS. FEEDERS SHALL BE THHN OR THWN (SEE RISER). B. WIRE AND CABLE FOR USE ON SYSTEMS OF BELOW 50 VOLTS SHALL BE 300 VOLT PVC INSULATED AND SUITABLE FOR THE CLASS OF WIRING EXCEPT AS OTHERWISE INDICATED OR SPECIFIED. C. ALL CONDUCTORS SHALL BE COPPER. 11. LIGHTING FIXTURES AND LAMPS: A. FIXTURES SHALL BE COMPLETE WITH ALL REQUIRED ACCESSORIES AND EQUIPMENT, INCLUDING LAMPS, NECESSARY FOR A COMPLETE INSTALLATION. CONTRACTOR SHALL RECEIVE, UNPACK, ASSEMBLE AND INSTALL FIXTURES INDICATED AS BEING FURNISHED BY OTHERS. B. FLUORESCENT BALLASTS SHALL BE CBM, ETL APPROVED, HIGH POWER FACTOR "P" RATED WITH A SOUND RATING OF "A". BALLASTS FOR INTERIOR USE SHALL BE HIGH FREQUENCY ELECTRONIC TYPE WITH A THO OF LESS THAN 20%. FIXTURES SHALL COMPLY WITH LOCAL LIGHTING CODES. C. 4' FLUORESCENT LAMPS SHALL BE F32T8 TYPE BY PHILLIPS, GE OR SYLVANIA, COLOR AS INDICATED ON PLANS. ALL A -TYPE LAMPS SHALL BE 130 VOLT AND 35K TEMPERATURE RATING. D. VERIFY THE CEILING OR WALL CONSTRUCTION, VOLTAGE AND THE MOUNTING REQUIREMENTS OF EACH FIXTURE AND PROVIDE PLASTER FRAMES, SPECIAL FLANGES, CONCRETE POUR HOUSINGS, BOXES, BRACKETS, ADAPTERS, HANGERS, STEMS, CANOPYS, SPECIAL BALLASTS OR LENSES AND OTHER MATERIALS NECESSARY TO PROPERLY PURCHASE AND MOUNT THE FIXTURE. E. SUBMIT SHOP DRAWINGS ON ALL FIXTURES AS REQUIRED UNDER SUBMITTALS". "SHOP DRAWINGS" MAY BE CATALOG DATA SHEETS IF COMPLETE INFORMATION INCLUDING MOUNTING HARDWARE IS SHOWN AND IDENTIFIED. SHOP DRAWINGS SHALL INCLUDE MOUNTING DETAILS AND SHOW COMPATIBILITY WITH THE CEILING OR OTHER EQUIPMENT. 12. NAMEPLATES AND LABELS: A. NAMEPLATES SHALL BE PROVIDED FOR CIRCUIT BREAKERS IN THE MAIN SWITCHBOARD, SWITCHES, AND TO IDENTIFY EACH PANELBOARD AND SIMILAR ITEMS WHICH ARE FURNISHED OR INSTALLED UNDER THIS SECTION. B. NAMEPLATES SHALL BE ENGRAVED LAMINATED PLASTIC WITH CHARACTERS CUT THROUGH THE BLACK TOP LAYER TO WHITE LAYER BELOW. 13. TIME SWITCHES: A. TIME SWITCHES SHALL BE INTERMATIC OR TORK. TYPE OF MOUNTING, POLES, VOLTAGE, AMPACITY AND ARRANGEMENT SHALL BE AS SHOWN ON DRAWINGS OR REQUIRED BY CONDITIONS. TIME SWITCHES CONTROLLING LIGHTING SHALL HAVE BAFTERY BACKUP AND ANY OTHER FEATURES SHOWN ON THE PLANS OR REQUIRED FOR PROPER OPERATION. B. ENCLOSURES SHALL BE NEMA I FOR INTERIOR DRY LOCATIONS. 14. RELAYS: A. RELAYS FOR MOTOR CONTROL SHALL BE HEAVY-DUTY INDUSTRIAL TYPE, MECHANICALLY HELD, WITH BOTH NORMALLY OPEN AND CLOSED CONTACTS. B. SUBMIT SHOP DRAWINGS AS REQUIRED UNDER "SUBMITTALS". EXECUTION 1. INSTALLATION AND CONNECTION OF ELECTRICAL EQUIPMENT: A. EQUIPMENT FURNISHED BY OTHERS SHALL BE COMPLETELY CONNECTED TO THE ELECTRICAL SYSTEM EXCEPT AS NOTED ON THE DRAWINGS. ALL FUSES, BREAKERS AND DISCONNECTS SHALL BE PROVIDED AS NECESSARY FOR PROPER PROTECTION. PROVIDE ALL FLEXIBLE CONDUIT, BOXES, FITTINGS, RECEPTACLES, CORDS, PLUGS AND OTHER MATERIAL REQUIRED FOR PROPER INSTALLATION. REFER TO MANUFACTURER'S DIRECTIONS WHERE APPLICABLE. 2. WORK ON HVAC AND PLUMBING SYSTEMS: A. COMPLETE POWER CIRCUITS, INCLUDING BREAKERS, SWITCHES, DISCONNECTS, WIRE AND CONDUIT, OUTLETS AND CONNECTIONS TO HVAC AND PLUMBING EQUIPMENT SHALL BE PROVIDED UNDER THIS SECTION. B. STARTERS AND CONTROLLERS SHALL BE PROVIDED UNDER THIS SECTION EXCEPT WHERE PART OF A PACKAGE UNIT OR PANEL SPECIFIED IN DIVISION 15. C. HVAC AND PLUMBING CONTROL AND INTERLOCK WIRING REGARDLESS OF VOLTAGE, AND CONDUITS FOR SAME, WILL BE WIRED AND CONNECTED UNDER THIS SECTION. 3. INSTALLATION OF CONDUIT: A. STANDARD WEIGHT RIGID METAL CONDUIT SHALL BE USED WHERE EXPOSED TO THE WEATHER, PLACED UNDERGROUND BELOW CONCRETE SLAB, IN CONCRETE OR MASONRY CONSTRUCTION IN CONTACT WITH EARTH, AND WHERE SHOWN ON THE PLANS. B. GALVANIZED STEEL ELECTRICAL METALLIC TUBING SHALL BE USED IN ABOVE GROUND, INTERIOR, DRY LOCATIONS PROTECTED FROM WEATHER AND PHYSICAL DAMAGE, AND MAY BE USED IN CONCRETE OR MASONRY CONSTRUCTION NOT IN CONTACT WITH EARTH. C. FLEXIBLE METALLIC CONDUIT SHALL BE USED WHERE SHOWN ON THE PLANS AND TO CONNECT CONDUIT SYSTEMS TO MOTORS, DIRECT WIRED AND VIBRATING EQUIPMENT AND AS A FINAL CONNECTION TO LIGHTING FIXTURES (6' MAX) IN ACCESSIBLE CEILINGS. IT MAY BE USED AS A WIRING SYSTEM INSTEAD OF EMT IN INTERIOR WALLS ONLY (DRY FRAME OR STUD CONSTRUCTION). D. LIQUIDTIGHT FLEXIBLE METAL CONDUIT SHALL BE USED FOR FINAL ELECTRICAL CONNECTIONS TO ROOF TOP OR OTHER EQUIPMENT EXPOSED TO THE ENVIORNMENT. E. RIGID NON-METALLIC CONDUIT MAY BE USED FOR ALL UNDERSLAB OR UNDERGROUND WORK IN PLACE OF STANDARD WEIGHT RIGID METAL AND WHERE SPECIFICALLY SPECIFIED. ALL RUNS OF RIGID NON-METALLIC CONDUIT SHALL CONTAIN A SEPARATE GREEN GROUND WIRE ADEQUATELY SIZED FOR SERVICE INTENDED. WHERE REQUIRED TO CONTINUE ABOVE SLAB, STUB NON-METALLIC CONDUIT 6" ABOVE SLAB THEN MAKE PROPER TRANSITION TO METAL CONDUIT. F. ALL RIGID STEEL CONDUIT INSTALLED IN THE GROUND SHALL BE WRAPPED WITH HUNT'S PROCESS NO. 3, PVC COATED OR ENCASED IN 3" CONCRETE ON ALL SIDES. G. THE MINIMUM SIZES OF CONDUIT SHALL BE CODE SIZE FOR THE NUMBER AND SIZE OF CONDUCTORS, UNLESS A LARGER SIZE IS SHOWN, IN WHICH CASE SUCH LARGER SIZE SHALL BE USED. H. ALL FINAL CONNECTIONS TO MOTORS SHALL BE FLEXIBLE METAL CONDUIT AND AS SHOWN ON DRAWINGS. I. WHERE PORTIONS OF RACEWAYS OR SLEEVES ENTER AREAS SUCH AS COLD STORAGE OR WHERE PASSING FROM THE INTERIOR TO THE EXTERIOR OF A BUILDING, THE RACEWAY OR SLEEVE SHALL BE FILLED WITH AN APPROVED MATERIAL TO PREVENT THE CIRCULATION OF WARM AIR TO A COOLER SECTION OF THE RACEWAY OR SLEEVE. 4. INSTALLATION AND CONNECTION OF WIRING: A. NO ROMEX CABLE WILL BE PERMITTED ON THIS PROJECT. ALL WIRING SHALL BE INSTALLED IN CONDUIT, WIREWAYS, OR GUTTERS, EXCEPT WHERE OTHER RACEWAY SYSTEMS OR METHODS ARE SPECIFICALLY SHOWN. B. CLEAN OUT AND DRY ALL CONDUIT AND WIREWAYS BEFORE PULLING ANY WIRES. USE NO LUBRICANT EXCEPT AS RECOMMENDED BY THE WIRE OR CABLE MANUFACTURER. C. MAKE ALL CONNECTIONS AND SPLICES NECESSARY TO PROPERLY COMPLETE THE ELECTRICAL WIRING. CONNECTIONS AND SPLICES SHALL BE MADE ONLY IN PULL, JUNCTION OR OUTLET BOXES, OR IN SWITCHBOARDS, WIREWAYS OR PANELS HAVING SUFFICIENT CODE SIZED GUTTER SPACE. CONNECTIONS AND SPLICES IN WIRES SMALLER THAN NO. 6 AWG SHALL BE MADE WITH SPRING TYPE CONNECTORS, AND IN WIRES NO. 6 AWG AND LARGER SHALL BE MADE WITH COMPRESSION, VISE TYPE, OR SPLIT BOLT SOLDERLESS CONNECTORS, INSULATED AND TAPED. 5. TELEPHONE SYSTEM: A. FURNISH AND INSTALL COMPLETE CONDUIT AND TERMINAL SYSTEM FOR TELEPHONE SERVICES AS INDICATED ON DRAWINGS. B. INSTALL A 1/8-INCH POLYETHYLENE PULL -IN WIRE IN EACH CONDUIT RUN. C. TELEPHONE WALL OUTLETS SHALL BE 4-11/16 INCH SQUARE BY 2-1/8 INCH DEEP METAL BOXES, WITH PLASTER RING AND SINGLE BUSHED OUTLET FLUSH TELEPHONE PLATE. D. FURNISH AND INSTALL 3/4-INCH CONDUIT FROM THE TELEPHONE EQUIPMENT ROOM MAIN TELEPHONE BACKBOARD TO NEAREST ACCESSIBLE COLD WATER GROUND. THIS CONDUIT SHOULD BE TERMINATED IN SUCH A MANNER THAT ACCESS TO GROUNDING DEVICE MAY BE HAD AT ANY TIME IN THE FUTURE. *-PER NEC 250 & NEC 800* 6. GROUNDING: A. MAKE GOOD MECHANICAL AND ELECTRICAL CONTACT AT ALL POLES, PANELBOARDS, SWITCHBOARDS, OUTLET BOXES, JUNCTION BOXES, AND WHEREVER THE CONDUIT RUN IS CONNECTED. PERMANENTLY AND EFFECTIVELY GROUND ALL CONDUIT, FIXTURES, MOTORS AND OTHER EQUIPMENT AS REQUIRED BY ALL APPLICABLE CODES, REGULATIONS AND STANDARDS. NEC 250 7. CLEANING AND PROTECTION OF PRODUCTS AND Mf'%1-h Atr%1-f1_ A. AT FREQUENT INTERVALS DURING THE TIME OF CONSTRUCTION, THE CONTRACTOR SHALL CLEAN UP AFTER HIS WORK AND REMOVE HIS DEBRIS FROM THE PREMISES, LEAVING THE BUILDING AND GROUNDS CLEAN TO THE OWNER'S SATISFACTION. B. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT ALL MATERIALS, EQUIPMENT AND PROPERTY, WHETHER ELECTRICAL OR NOT, FROM DAMAGE AS A RESULT OF HIS WORK. 8. CHECKING AND TESTING OF EQUIPMENT AND SYSTEMS: A. PANELS, DISCONNECTS, STARTERS AND OTHER EQUIPMENT INSTALLED UNDER THIS SECTION SHALL BE INSPECTED FOR DEFECTS AND TESTED FOR PROPER OPERATION. B. SYSTEMS SHALL BE TESTED FOR SHORT CIRCUITS, OPEN CIRCUITS AND WRONG CONNECTIONS AND SHALL BE FREE FROM MECHANICAL AND ELECTRICAL DEFECTS. CIRCUITS SHALL BE TESTED FOR PROPER NEUTRAL AND GROUND CONNECTIONS. 9. TEMPORARY CONSTRUCTION POWER & TELEPHONE: A. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, COST AND MATERIALS REQUIRED FOR INSTALLATION AND MAINTENANCE OF TEMPORARY CONSTRUCTION POWER AND TELEPHONE. CONSTRUCTION POWER SHALL BE MINIMUM OF 100A, 120/208V /1 PHASE, 4W, WITH PROVISIONS FOR ONE 50A, 208V, 2P, 4W GROUNDING RECEPTACLE AND FOUR 120V, 20A, 1 P RECEPTACLES. 10. SUBSTITUTIONS: A. ALTERNATIVE MANUFACTURER'S WILL BE CONSIDERED FOR ELECTRICAL DEVICES, SWITCHES, OUTLETS, ETC. NOT PROVIDED BY OWNER. B. CATALOGS, DATA SHEETS OR SHOP DRAWINGS SHALL BE SUBMITTED TO THE CONSTRUCTION MANAGER FOR ALL ALTERNATIVE MANUFACTURED EQUIPMENT AS REQUIRED UNDER "SUBMITTALS". 11. COMMISSIONING: A. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR LIGHTING SYSTEM FUNCTIONAL TESTING AS REQUIRED BY C408.3.1 OF THE IECC-WA OUTLINED BELOW: TESTING SHALL ENSURE THAT CONTROL HARDWARE AND SOFTWARE ARE CALIBRATED, ADJUSTED, PROGRAMMED AND IN PROPER WORKING CONDITION IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. WRITTEN PROCEDURES WHICH CLEARLY DESCRIBE THE INDIVIDUAL SYSTEMATIC TEST - PROCEDURES, THE EXPECTED SYSTEMS' RESPONSE OR ACCEPTANCE CRITERIA FOR EACH PROCEDURE, THE ACTUAL RESPONSE OR FINDINGS, AND ANY PERTINENT DISCUSSION SHALL BE FOLLOWED. AT A MINIMUM, TESTING SHALL AFFIRM OPERATION DURING NORMALLY OCCUPIED DAYLIGHT CONDITIONS. WHERE OCCUPANT SENSORS, TIME SWITCHES, PROGRAMMABLE SCHEDULE CONTROLS, PHOTOSENSORS OR DAYLIGHTING CONTROLS ARE INSTALLED, THE FOLLOWING PROCEDURES SHALL BE PERFORMED: 1. CONFIRM THAT THE PLACEMENT, SENSITIVITY AND TIME-OUT ADJUSTMENTS FOR OCCUPANT SENSORS YIELD ACCEPTABLE PERFORMANCE. 2. CONFIRM THAT THE TIME SWITCHES AND PROGRAMMABLE SCHEDULE CONTROLS ARE PROGRAMMED TO TURN THE LIGHTS OFF. CODE city BUILDI RECEIVED CITY OF TUKWII.A SEP 15 2015 ABOSSEIN ENGINEERING L.L.C. MECHANICAL. I ELECTRICAL I CML LEED I FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PHONE: (425) 462-9441 w w � J a 5 Li Q- 5 _J `Z m Lim I co U) w O > w z 2 J J a (n Z W (= I- I- w 0- w N m W CL a- u7U)o�aa fn CD J 0 J U_ z z a WLLI CD o J a J a z - W W J a.a.==mww W W W D J J LU N \ � r LO LO N Q LO V) 0 2015 Project Number 215042 Sheet Name ELECTRICAL SPECS Sheet Number 3. CONFIRM THAT THE PLACEMENT AND SENSITIVITY ADJUSTMENTS FOR PHOTOSENSOR CONTROLS REDUCE ELECTRIC LIGHT BASED ON THE AMOUNT OF USABLE DAYLIGHT IN THE SPACE AS S D_ PERMIT CENTER