HomeMy WebLinkAboutPermit EL15-0831 - STUDIO PIZZA - WIRINGSTUDIO PIZZA 17250 SOUTHCENTER PKWY EL15-0831 City of Tukwila • Department of Community Development « 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 7888920020 Permit Number: EL15-0831 Address: 17250 SOUTHCENTER PKWY 148 Issue Date: 11/9/2015 Permit Expires On: 5/7/2016 Project Name: STUDIO PIZZA Owner: Name: WIG PROPERTIES LLC-SS Address: 4811 134TH PL SE, BELLEVUE, WA, 98006 Contact Person: Name: JASON NIX Phone: (206) 948-0202 Address: 355 118 AVE SE, SUITE 100, BELLEVUE, WA, 98005 Contractor: Name: HOME RUN ELECTRIC LLC Phone: (425) 489-0791 Address: PO BOX 217, BOTHELL, WA, 98041 License No: HOMERRE974K2 Expiration Date: 5/22/2017 Lender: Name: Address: DESCRIPTION OF WORK: WIRE TENANT IMPROVEMENT PER PLAN FOR NEW TENANT (STUDIO PIZZA) Valuation of single family: $0.00 Fees Collected: $813.54 Valuation of mf/comm: $30,000.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: fjyi'OOh�/t�1 c� Date: I you /s- Print Name: or"n h SM i fh This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB V CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. � L- Is- -' oos I Project No. Date Application Accepted: Date Application Expires: (� use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.::11M%o 2k -ocean Site Address:v-1aksp \,L CP�n�tF'� �4�1.�7q Suite Number:_ Tenant Name: r) New Tenant: .....Yes ❑ ..No PROPERTY OWNER Name: WT 1�>,ro le's Luc Address: LAII�CM C34� (AL-5 City: �v\e� U, State: 4 Zip CONTACT PERSON - person receiving all project communication Name: T \ C on Address: V,V 64 Sf-- 51 _ , City ` Stater, Zip$ Phone: go(, _0% qj - ()Xgax:9W _ DW -OU1 LA Email: m v-\ ` GunsAn&e:Hcn 11eA- sari Valuation of Project (contractor's bid price): $ O, 000 Scope of Work (please provide detailed information): (-An rn �r- hlza1 S 4-p >,n +- I 1 ELECTRICAL CONTRACTOR INFORMATION Company NameA�Dwie-%t,,,(::i, k�,G u,ci Address(10,bm A k-1 City: �� State:Zit PhoneiA.�-5'4(�Cl "(,, Fax: q.XS -LA Zq -7pl6l Contr Reg No. u&,\ q1 Exp Date: -V Tukwila Business License No.; �S 3 Will service be altered? ❑ Yes W No Adding more than 50 amps? ❑ Yes ( [XI No Type of Use:_ -ow\w"e�0A Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel l QQ j Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ® Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms-Applications On LineU014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits.................$81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ...........$54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary 'service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals....................................................................$80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: t Print Name � k t!1 `) Mailing H:Wppliwtions\Forrris-Applications On Line\2014 ApplicationsElectrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Date: ��\S Day Telephone: LU"s City State Page 2 of 2 DESCRIPTIONS• QUANTITY PermitTRAK PAID $813.54 EL15-0831 Address: 17250 SOUTHCENTER PKWY 148 Apn: 7888920020 $813.54 ELECTRICAL $782.25 PLAN CHECK FEE R000.345.832.00.00 0.00 $156.45 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $625.80 TECHNOLOGY FEE $31.29 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL' R6257 $31.29 $813.54 Date Paid: Friday, September 25, 2015 Paid By: JOHN SMITH Pay Method: CREDIT CARD 08620G Printed: Friday, September 25, 2015 10:40 AM 1 of 1 pfSYSTEMS City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director October 05, 2015 JASON NIX 355 118 AVE SE, SUITE 100 BELLEVUE, WA 98005 RE: Correction Letter # 1 ELECTRICAL Permit Application Number EL15-0831 STUDIO PIZZA - 17250 SOUTHCENTER PKWY, SUITE 148 Dear JASON NIX, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - E DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. • CORRECTIONS/ #1 1.) LIGHTING ALLOWANCE SUMMARY REQUIRED. 2.) LOAD CALCULATIONS REQUIRED. 3.) ONE LINE SERVICE RISER DIAGRAM REQUIRED. INCLUDE PANEL SCHEDULE. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accented through the mail or by a messenger service. If you have any questions, I can be reached at (206)431-3665. Sincerely, NEI Bill Rambo2 Permit Technician File No. EL15-0831 6300 Southcenter Boulevard Suite #100 9 Tukwila Washinkton 98188 • Phone 206-431-3670 9 Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0831 DATE: 10/26/15 PROJECT NAME: PIZZA STUDIO SITE ADDRESS: 17250 SOUTHCENTER PKWY - SUITE 148 Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division Fire Prevention Public Works ❑ Structural PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: ❑ Planning Division ❑ ❑ Permit Coordinator DATE: 10/27/15 Structural Review Required ❑ DATE: DUE DATE: 11/24/15 Approved with Conditions Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORQ COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0831 PROJECT NAME: PIZZA STUDIO DATE: 09/25/15 SITE ADDRESS: 17250 SOUTHCENTER PKWY - SUITE 148 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 09/29/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: DATE: DUE DATE: 10/27/15 Approved ❑ Approved with Conditions ❑ Corrections Required (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: r� ✓� Departments issued corrections: Bldg k Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: ht�p:1/t,�is�ss.eLtirktvila.iva.trs REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: fU c�-, � \5 Plan Check/Permit Number: EL 15-0831 ❑ Response to Incomplete Letter # ® Response to Correction .Letter # 1 AECEM CRY OF `P1jw*u ❑ Revision # ^ after Permit is Issued 002,62015 ❑ Revision requested by a City Building Inspector or Plans Examiner P,£iiAVT ;t",F Project Name: Pizza Studio Project Address: 17250 Southcenter_PkM — Suite 148 Contact Person� C� i'W, Phone Number: _ L- AG � Summary of Revision: A, Lnd' O al c Lt_ Qi ,(' s 4M PA C)ne --\ tine sei c0 i S� Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 414 F Entered in TRAKiT on % 16g, // // \appl icat ions\ orms-applications on ImeVevision submittal Created: 8-13-2004 Revised: INSPECTION RECORD �. Retain a copy with permit INSPECT ON N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 l Project: Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: p•mr Requester:, /If Phone No: r REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 3 INSPECTION RECORD &� Retain a copy with permit I INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �l Z Type of Inspection: 1 G' Address: Date Called: Special Instructions: Date Wanted: 41�' 1( p.m. Requester: rFone—N —o: AApproved per applicable codes. LJ Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD I Retain a copy with permit _0�3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: EJz�Asinprc Type of Inspection/ �AJ Address: / / 7Z,570 6 � - • N. Date Called: Special Instructions: iy Date Wanted: ! I I / P.M. ---- Requester: /-i -- Phone No: 2-5-' Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. / INSPECTION RECORD ` Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: t a / Typg Qf Inspection: !� �U �/1.�f2 /�4Jc0 Address: Date Called: Special Instructions: Date Wanted: i (C� p•m Requester: / e— Phone No: Z�I Lp(� 121 Approved per applicable codes. t_J Corrections required prior to approval. 1 1, / '-a'I I--- "')Jr -4-6i /P^ . IN- I r nspector Date: Ct REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. '4K V . AT IN Y E R,1 U FOR: P."echanicai [1 Sectrical Numbing c,�s Piptng :rl of Tukwila I" 1 DIVISII A�,C;F�ZA S U D F—y—R1GA1 17250 SOUTHCENTER PARKWAY TU KWI LA, WA J8-1 68 LIGHTING FIXTURE SCHEDULE Light Type Description BRAND/MODEL Lamp Type Lamp Quantity Lamp Wattage Total Wattage Qty. NOTES A 6"LEODOWNUGHT EUTEUGHTING/RL628.95OL-DIMTR-1203DK-W-WH LED 1 1SW 15W 31 PROVIDE DIMMER FOR HALL UGHTING AND ALL DINING ROOM LIGHTING- NO DIMMING REQUIRED ATFOODPREPAREAS A-C 6°COMPACFHOUSING EUTE UGHTING/RL628-LDS-AT-DIMTR-120 N/A N/A N/A N/A 31 A3 4"LED DOWNUGHT EUTEUGHTING/RL428-65OL-DIMTR-120-30K-W-WH LED 1 31W 11W 2 PROVIDE DIMMER FOR HALL LIGHTING AND ALL DINING ROOM LIGHTING- NO DIMMINGREQUIRED AT FOOD PREP AREAS A3-C 4" COMPACT HOUSING EUTEUGHTING/RL628-LD41GAT-DIMTR-120 N/A N/A N/A N/A 2 B CUSTOMPIZZA PAN PENDANT HI LITE/PS 101 LED 1 12WZBW 3 BOTTOM OF FIXTURE@T-4"AFF C PENDANT CAN FIXTURE ELITE LIGHTING/SC61NC-PM48-120-6101-MB-P LED 1 2OW22 BOTTOM OF FIXTURE @1D-6"AFF 0 PIPE MOUNTED CLAMP LIGHT NORA UGHTING/NTH-I50-NT-340B BARN DOOR LED 1 17W23 (6)PIPES & (23) HEADS CLAMP TO PIPE RAIL PER DETAIL WITH "CONTECH"LASIBRP-B LIGHT CLAMP MOUNT @10'-0"AFFTO BOTTOM OF PIPE E 2X4LED RECESSED TROFFER LUMINAIRE ORACLE UGHTING/24-OT-LED-40ODL-DIMIO-MVOLT-40K-80-Al2 LED 1 39W7 F MONOPOINT CORE LIGHTING GROUP/CTL-41PL1-30K-WH-FL-MP LED 1 16WEX LED EXIT SIGN BEST LIGHTING/EZXTEU-I-G-W-EM LED 1 SW 2 EM INCONDESCENT EMERGENCY UNIT BESTLIGHTING/RS LED 2 5.4W 10.8W 3 REVISIONS No changes shall be made to the- scope of k-i nrk ivithn,it prior approval of Building Division. wiii require a new plan submittal I and may ine ;:ds additional plan review fees. t FILE COPY Permit No. �� — �� Plan review approval is subject to errors and omissions. approval &t i:crostruction documents does not authorize t; :3 violation of any adopted code or ordinance. Recut of approved Field Copy and eondidans is acknowledged: Date: ` A/0 V S' City of Tukwila BUILDING DIVISION Specify Compliance Method on LGT-SUM Arse• LP.,,.P(Plan R. room C) Fi Dte pl - NO erd FJ-- W— Flyture Woba ftPPPed -Py ALL FIXNN: TYPE • A 3i is 466 4, ALL —5Z;; : AD a 11 is ., ALL FIXTURETYPE•a 3 1i 36 —b ALL FOITIIRE TYPE c 22 R0 440 oney j—h 2a 17 391 UNp• A —RE ME • E 7 aE 266 Fa ALL f0flwiE TYPE F 5 16 80 P«n9y FIXTUI¢ENeAEPymPy All NATURE ttPE . E% M—T a ' Selew Ta0q C40b a,1(I)audmn9Ane aom 4'OP tlDVn menu. •• 1ruYutls eykll� bnemNn N9htlng4ntl ezempl dBl�En9a9ulPmenlper nObp pelow. Compliance by Building Area �!J Ilrck�iilihilr Tabl 17zz 17ao Nwea: 1. PmPDapdwana9. a p.cAaPkdm9Mr tyro enarnwpycaw maalmee wpm9. brwl ewldn9Ms rypa. Tremry neva9. nPn Pn Bw'blrp Amp ryyoD Ip IbttNopatl Undarme auawtgAryp Alemotl rwnPliancepem. 2. PmpP d=s must by tiatadb ba bPildPlo ma in Ahlch 9«y Pxur, IPw at Prt dffi'19M,;_9 9. AF PM—d Flkbn Dapcnpd., IndlWe—ypa,/amp Oma(a.g .T4). numDefwlampe tR lAa Pztwe, eml DalleHrype (NNWudptlJ. Fo apw,ili9hdrp,lialbe brrgdrwma Deck fin Ise4 in edd/Gonb the PPP MV. e^dWllaplinbrma0on, <. WpRpoaatl WalfslFAWre. uaa manbacbxp/p Fsbdmanmum inpul xaGpa uFD«0zhve (nw pfmpyda lamp pebaye) erp dlbr aPadf.tlm samnc4os.s.1. Pw rm. wa9a back rgn6n9,tisl m.9r.awa.w.arbm;.lvmaaav arlermm woad: mwdpwtlby soeS CORRECTION LTR#_U-- LAX NNmg LJLMW o h<m REVIEWED FUR COMPLIANCE WITH ' C/22 a�a YO NFPA70 - NEC �� Q mob goal NOV 0 3 2015VINSTALLING CONTRACT013: City of Tukwila BUILDING DIVISION R"""` Pre PO Bp»c 2 27 Ph... ( 5) 4 9- 0 91 Fax: (425) 4e19-7996 '. N VICINITY MAP DRAWING INDEX SHEET NO. SHEET DESCRIPTION E0.1 TITLE SHEET E3.1 LOAD CALCS & ONE LINE DIAGRAM FL15— 0831 RECEIVED CITY OF TUKWILA OCT 2 6 2015 PERMIT CENTER 0 0 Q N N Q W W I P9AEn. SAFE Adrian M. Steik „maw 10/23/15 E0s 1 DRAWINGONLYTO SCALE IF PL07TEDAT24•X 36'Ate6re ' i sG a W� itNgx �W Nam Cl�� �3A Oho 05M( 1f0 a mI� N08 E@ aF INSTALLING CONTRACTOR: . Pan .eye Pal Box 17 BotMaall WA- 98042 Phone:: (425) 489-0791 Fa- (425)489-7996 Q O :e CO 0 REVIEWED FOR Q� Z EXISTING SUB PANELS INSTALLED IN SUITE- COMPLIANCE WITH � Q sees NPPA 70 4 NEC �`7i w Panel- IdBA Panel - 1468 z / z MA1N LUG 200 MP MAIO AMONLY ��� 03 2015 1 ENSRNG METEMG 42 CI -It 42 Clrcuil :13 �/ 120/208v 120/208v f O V I48A I. 3p/4w 3p/4w � � ;A O O City of Tukwila � � N� BUILDING DI!/lBl�� I "� 200/3 Z00/3 ^ ly F W O RECEIVED SAFE CITY OF TUKWILA EHEOF09Y Adrian M. Steik NOTQATR 10/23/15 T E9 /�df- 1 2 6 L/ , 5 �g,��.g„� 15-118 ERSRNG SUB FEEDS TO SUITE - NO CHANGES TO BE MADE - PERMIT CENTEREl I DRAWING ONLY TO SCALE IF ROTTED AT 24'X36' EXE6TNUMeER PANEL: SUITE-148A PANEL SCHEDULE PROJECT: PIZZA Ltt IGHTING - ROOM 70a, 107, ]OB 326 l 20 B 20 R 840 RKEPT. -DIMNG M. Luj I STUDIO 120/ZOB v. 3 PH - 4 W 200 MP MAIN LUG ONLY LOCATION: ELECTRICAL ROOM- Ckt. Description / location Lead load [8 PHASE [B Inatl load Description / Location Ckt No. (VA 1 Type AmP AmD Type (VA) I No. 1 UGHi1NG-ROOM 101, 303 1,107 L 30 A 20 R 900 RKEPT. -DIMNG RM. 101 2 3 PANEL: SUITE-1A8B PANEL SCHEDULE PROJECT: PIZZA STUDIO 120 /208 v. 3 PH - 4 W 200 MP MAW LUG ONLY LOCATION: ELECTRICAL ROOM- ' Description /Location lead lead ® PHASE [B Load Load Description / location O'T- No. (vAI type anp Amp Tvce (VA) No. 1 GAS WATER HEATER 300 E 20 A 20 E 191 793 ITEM #44 WALK IN REFER 2 4 3 ITEM k60 380 E 20 B S ITEM#fi0 I80 E 20 C 20 E 916 915 ITEM p45 WAlK IN FREEZER 6 8 ] ITEM#3 1$00 E 20 A 9 ITEMg3 1500 E 20 B 20 E 835 ITEM boa- I DATE IINm r ACCESSIBLE RESTROOM SIGNS NOSCALE ALL HANDICAP ROOMS TO HAVE SIGNAGE PER ICC 11 101.2.9. (ICC Al 17.1 SECTION 703.6.3.1) ALL INTERIOR SIGNS DEPICTING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL COMPLY WITH SECTION 703 (ICC A117.1 SECTION 703) ALL ACCESSIBLE SIGNAGE DEPICTING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE WHITE ON A BLUE BACKGROUND PER 1101.2.9 IN THE WA STATE AMENDMENTS TO THE IBC. MOUNT ACCESSIBLE SIGNS 40" MIN A.F.F., MEASURED TO THE BASELINE OF THE CHARACTER PER ICC/ANSI 1 17.1-2003 SECTION 703.4.5 ALL COUNTERTOP EDGES ON PUBLIC SIDE OF COUNTERS TO BE ROUNDED. BLACK RUBBER T-MOLD TO BE USED AT LAMINATE TOPS. AND BULLNOSED EDGE AT SOLID SURFACES. ACCESSIBLE PATH OF TRAVEL — GREATEST DISTANCE TO EXIT ✓r RESTROOM SIGNAGE _ _ — — - — — — — — — — 3-0. ACCESSIBLE SYMBOLS KEY SCALEY F-0- �% c 18"X60' MANEUVERING CLEARANCE 1a' I 0 PULL SIDE OF DOOR FRONT APPROACH z 12"X48" MANEUVERING m CLEARANCE ! 0 PUSH SIDE OF DOOR �J j FRONT APPROACH WITH -- - - LATCH AND CLOSER 36"X60" MANEUVERING CLEARANCE 0 PULL SIDE OF DOOR 36' HINGE APPROCH 22"X48" MANEUVERING 22' jlz CLEARANCE �\ v 0 PUSH SIDE OF DOOR FOR HINGE SIDE APPROACH WITH LATCH AND CLOSER 42"X54- MANEUVERING CLEARANCE 0 PULL SIDE OF DOOR 9 HINGE APPROACH 4z' - ALTERNATE 24"X54" MANEUVERING CLEARANCE < 0 PULL SIDE OF DOOR LATCH APPROACH WITH - - 24-' CLOSER 24"X48" MANEUVERING z4" CLEARANCE e 0 PUSH SIDE OF DOOR FOR LATCH SIDE 17 __.. APPROACH WITH AND CLOSER WITHIN 30 FEET OF -THI COOKING EQUIPMENT` PER IBC 906.4 -- a COOK UNE X I I IF 1-03-1 I 3'-8' • I 60"X56" CLEAR FLOOR SPACE 0 FLOOR MOUNT TOILET 30"X48" CLEAR FLOOR Y SPACE 0 SINK - VERTICAL APPROACH 60" TURN AROUND m CIRCLE PORTABLE FIRE EXTINGUISHER SEMI -FLUSH MOUNT ,I I+30 ,I_430 I I- .I I - +30 NMNC 4` " ��i 1m REVIEWED OR COMPLIANCE�ECTH NFP NOV 0 3 2015 City ot.-IUKWIlar_ RECEIVED CITY OF TUKWILA SEP 2 5 2015 PERMIT CENTER, 1 fV i / I � F MAXIMUM OCCUPANT LOAD OF 49 PERSONS V% TO BE POSTED ADJACENT TO MAIN ENTRY DOOR C G ROVIOE SEMI FLUSH RE EXTINGUISHER — IFY LOCATION �,J,J EQUIREMENTS WITH CODE PLAN SCALE: Y"-V-0" 77 se PIZZA STUDIO Q Go aco m W L V CD 1n N n CODE PLAN Date: 8-12-15 Scale: NOTED Drawn by: VUL A.02 GWB CEILING 0 RESTROOMS, TYP. LEAVE GRID OPEN AT WATER HEATER LIGHTING SCHEDULE SYMBOL QTY DESCRIPTION MFR. MODEL # LAMPS DIMI REMARKS LAMPING FOR RECESSED ELITE LIGHTING RL628-95OL-DIMR- CAN 120 30K-W-WH YES PROVIDE DIMMERS FOR HALL LIGHTING 31 EA. 15W - AS AND ALL DINING ROOM LIGHTING - LED-3000K NOTE, NO OWNING REQUIRED AT FOOD CAN HOUSING ELITE LIGHTING RL628-LD6-AT PREP AREAS DIMTR-120 LAMPING FOR RECESSED ELITE LIGHTING RL428-65OL-DIMTR- CAN 0 BEVERAGE STATION 120-3OK-W-WH ® 2 �' 1W LED-3000K YES � CAN HOUSING ELITE LIGHTING RL628-L04IC-AT- DIMTR-120 O 3 EA, CUSTOM PFLZA PAN HI LITE PS 101 7.5W LED YES BOTTOM OF FIXTURE 0 7'-4°AFF B PENDANT TYPE A LAMP 22 EA. PENDANT CAN FIXTURE MAXILUME - ELITE SC61NC-PM48-120- 6101-MB-P 7.5W LED YE6 BOTTOM FIXTURE 0 10-6°AFF LIGHTING TYPE A LAMP 6 PIPES 23 HEADS PIPE MOUNTED CLAMP LIGHTS SEE PLAN FOR NORA LIGHTING NTH-150 - Nf-340 BARN DOOR LED1 YES CLAMP TO PIPE RAIL PER DETAIL WITH "CONTECH" -B LIGHT MOUNT PIPE LENGTHS PAR70 0 PIPE O 70-0" AFF TO BOTTOM OF PIPE FF TO 7 EA. RECESSED TROFFER ORACLE LIGHTING DIMIO-VOLT-0K- NWLT-40K- 78W LED NO E 80-A1 80-A72 OF 5 EA. MONO POINT CORE 12.5W LED NO GROUP -FL-MP-L7-30K-WH EXIT SIGNAGE- EGRESS BEST LIGHTING EXIT 2 EA. WITH BATTERY PRODUCTS EZXTEU-I-G-W-EM SIN LED NO BACK U BACK UP 3 EA, EGRESS LIGHTING BEST LICHTING R1 (2) 5.4W LED NO PRODUCTS QV 2 EA. RESTROOM EXHAUST FANS NUTON OR EQUAL TBS ® SEE FINISH SCHEDULE ON SHEET A6.1 ALL LIGHTING SPECS AND COST PER FIXTURE TO BE SUBMITTED FOR APPROVAL TO OWNER AND DESIGNER ELECTRICAL INFORMATION FOR REFERENCE ONLY - SEE ELECTRICAL PERMIT GENERAL NOTE: 'C' INDICATES CORRIDOR LIGHTING TO BE WIRED DIRECTLY TO PANEL. RESTROOM EXHAUST FAN TO BE SWITCHED W/ RESTROOM LIGHT — VERIFY EXISTING. DIMMER NOTE: CONFIRM DIMMER LOADS W/ MAX. LIGHT FIXTURE CAPACITY. ADD ADDITIONAL LIGHT SWITCHES, DIMMERS AS NEEDED. MATCH TYPE OF DIMMER TO TRANSFORMER TYPE ON LOW VOLTAGE FIXTURE — CONFIRM COMPATIBILITY NOTE: CEILING HEIGHT IS CALLED OUT FROM —0— GRADE. CEILING IS ONE CONSISTENT HEIGHT THROUGHOUT UNLESS NOTED OTHERWISE. 1 DO NOT PAINT DUCT WORK 2 PAINT METAL BRACKETS BLACK (P-2) 3 LEAVE ALL EXPOSED CONDUIT AND J BOXES BLACK (P-2) 4 NOT USED 5 ALL CEILING TILES IN THE PREP AND STORAGE ARES ARE TO BE SMOOTH, WASHABLE, NON ABSORBENT AND LIGHT IN COLOR. 6 ALL SPOT ELEVATION MAKERS ARE FROM FINISH FLOOR TO BOTTOM OF ITEMS UNLESS NOTED OTHERWISE. 7 ALL SUSPENSION OF NEW LIGHT FIXTURE, NEW HVAC DUCTING, SPEAKERS ECT. TO BE SUPPORTED FROM EXISTING STRUCTURE ABOVE. 8. REFER TO FINISH SCHEDULE FOR FINISH SPECIFICATION. 9. REFER TO ELECTRICAL DRAWINGS FOR COMPLETE SCOPE OF WORK. 10. ALL OUTLETS, REGISTERS, ECT. ON CEILING AND WALLS PAINTED TO MATCH SURFACE. 11 CENTER DOWN LIGHTING, PENDANTS LIGHTS, AND TRACK LIGHTING IN CEILING TILES AS SHOWN. REVIEWED* - CvC'MPL LANCE W i' a NFPA 70 - NIF r I NOV 0 3 2015 RECEIVED CITY OF TUKWILA REFLECTED CEILING & LIGHTING PLAN SCALE: Y° = 1--0" SEP 2 5 2015 PERMIT CENTER Ln N 1 ~b W tn 7— W a I DATE i 1NrT1 e PIZZA STUDIO Q DO 00 �td00 m J m W V O Lrl N N REFLECTED CEILING PLAN Date: 8-12-15 Scale: NOTED Drawn by: MIL A3.11 I DATE I mril VENT TO OUTSIDE t EXISTING SINK PLUMBING - VERIFY LOCATION VERIFY PLUMBING DRAIN LOCATIONS WITH TOILET SPEC Lo `A. �C � �-i, V yFfl'f AESjNDOM 16 -54.=Q • .i ; 107 I 6" I � � 'I r-lL o I OFM E as _6• EXISTING ELECTRICAL PANEL" I VERIFY EQUIPMENT REQUIREMENTS WITH FINAL EQUIPMENT SELECTIONS ELECTRICAL KEY KEY DESCRIPTION QC DUPLEX OUTLET 4-PLEX OUTLET ® J-BOX ® 220/110 CONNECT (VERIFY PLUG CONFIGURATION W/EQUIP SPEC SHEET) A PHONE CONNECTION: P=PHONE, F=FAX © CEILING MOUNTED CO-AX CABLE CEILING MOUNTED DUPLEX OUTLET General Electrical Notes • ALL STUB UP DIMENSIONS FROM FINISHED FLOOR TO CENTER OF BOX. • EQUIPMENT LISTED ON EQUIPMENT SCHEDULE WILL BE UNCRATED AND SET IN PLACE ONLY. ROUGH IN AND FINAL HOOK-UP BY ELECTRICAL CONTRACTOR. • ELECTRICAL CONTRACTOR TO FURNISH DISCONNECTS WHERE CODE REQUIRES. EQUIPMENT LISTED ON THE EQUIPMENT SCHEDULE DOES NOT INCLUDE ELECTRICAL FITTINGS SUCH AS RELAYS OR DISCONNECTS TO ELECTRICAL SERVICE. • THESE PLANS SHOW ONLY THE REQUIREMENTS LISTED ON EQUIPMENT SCHEDULE. • ALL KITCHEN EQUIPMENT OUTLETS TO BE GFl. SEE K SHEETS. • FIELD VERIFY LOCATION OF CONVENIENCE OUTLETS AND REUSE WHERE POSSIBLE. MECHANICAL KEY KEYJ DESCRIPTION O COLD WATER • HOT WATER DIRECT DRAIN - CLOSED Q INDIRECT DRAIN - BELL WASTE FLOOR DRAIN e— INDIRECT WASTE CONNECTION 12x12x8 FLOOR SINK (INDIRECT WASTE) ® NATURAL GAS CONNECTION OV AIR VENT FLOOR DRAIN WITH 3' X 3' DEPRESSION SLOPE TO DRAIN General Plumbina Notes • EQUIPMENT SCHEDULE DOES NOT SPECIFY ANY PLUMBING FITTINGS SUCH AS GREASE TRAPS, FAUCETS, PRESSURE REDUCING VALVES OR INTERCEPTOR, ETC. UNLESS LISTED ON EQUIPMENT SCHEDULE, NOR DOES IT INCLUDE FINAL CONNECTION TO SERVICE. PLUMBING CONTRACTOR TO PROVIDE IF NECESSARY. • PLUMBING REQUIREMENTS SHOWN ONLY FOR ITEMS LISTED ON EQUIPMENT SCHEDULE. • PLUMBER TO PROVIDE ROUGH -IN AND FINAL CONNECT. PER LANDLORD THERE IS A 16,000 SF GREASE INTERCEPTOR PROVIDED ON SITE WITH AN EXISTING TIE IN LOCATED WITHIN DEMISED SPACE PER LANDLORD PROVIDE NEW SUB METER DIRECTLY OFF 'T" FROM MAIN LINE - CONTACT LANDLORD FOR METER SPEC - TO HAVE REMOTE READER VERIFY ALL POWER AND SEE K- SHEETS DATA REQUIREMENTS FOR KITCHEN OF POS SYSTEM WITH EQUIPMENT OWNER FINFORMATION 1116P ARFA phi 29'-2" 1- 1 1 1 e 1 PLUMBING AND ELECTRICAL INFORMATION FOR REFERENCE ONLY - SEE PLUMBING PERMIT AND ELECTRICAL PERMIT — — — — — — - AREA F Ej 101 -'I 1i Flo-1-1—�.+. --- I, '' I ;1 - y -- q REVIEWED HUH COMPLIANCE WITH NFPA 70 - NEC NOV 0 3 2015 City of Tukwila BUILDING DIVISION REVIEW SHOP DRAWINGS FOR OUTLET LOCATIONS IN MILLWORK WALLS AND BOOTHS, TYP. RECEIVED CITY OF TUKWILA �- � SEP 2 5 2015 �N,N j PERMIT CENTER Ln I � 1 N I t_U 1 � REVIEW SHOP DRAWINGS FOR OUTLET L—REVIEW SHOP DRAWINGS FOR OUTLET LOCATIONS IN MILLWORK WALLS AND LOCATIONS IN MILLWORK WALLS AND LLI BOOTHS, TYP. BOOTHS, TYP. 0- ROOM i +n, IIN 11£� � own PLUMBING/ELECTRICAL SPOTTING PLAN SCALE: Y° = V-0« 4 PIZZA STUDIO Q co aco m LU U to O Ln N n N ECHIELEC SPOTTING PLAN Date: 8-12-15 Scale: NOTED Drawn by;M1L �� m REVISION I DATE IINIT1 REVIEWED FUH COMPLIANCE W1 KIFPA 70 m NEE NOV 0 3 2015 City ofi iulwaa �. BUILDIKIGDIVISIOF RECEIVE® CITY OF TUKWILA SEP 2 5 2015 PERMI U CEN 1 ER EQUIPMENT PLAN SCALR YS e F-O" PIZZA STUDIO a 00 00 d00 01 wg 0 Ln N n ti L" o H 00 �V1 C UK 3 ob00 N H 00 t N a� �00 D N In N rl 00 UTCEEN QUIPMENT LAN Date:8-12-15 �L Scale: NOTED Drawn by: MIL W d Job: PIZZA STUDIO TU K1 ✓ EQUIPMENT LIST MECHANICAL ELECRtIGI DESCRIPTION MANUFACTURER MODFl # HW CW WASTE BN's VOLr PH HP AMPS EIGHT PPLJ REMARKS I 1 EA WALL FLASHING AND TRW AT CUSTOM KEC POP DISPENSER PROWOEO BY CDMAENCIAL CUSTOM SEATING 2 1 LOT SNEEZE GUARD CU510N CCS INSTALLED BY CC MOUNTED ON ITEM /B 3 2 EA DOUGH PRESS PROLUX DP3300A 120 1 12.5 KEC 4 2 EA M X 30 SS WORT( TABLE BOOS STBRS-30MSBH-X KEC 5 1 EA W X M SS WORK TABLE BOOS SISRS-30SOSSK XEC 6 7 B 1 EA • PIZZA PREP CLISTON CCE PROVIDED BY INSTATED BY GCCOMMERCIAL GC TOCPRONOE StONIPoWEA IN WILL TNTA9t FOR ADJACENT EQUIPMENT 9 5 EA 12 X 00 WALL SHELF EGGS EWSB-1100-X KEC 6C TO PROWOE WAL BACNER 1N WKL 9.2 1 EA PAPER TOWEL BOOS 2-PIZZA-BA KEC OC TO PROVIDE WALL BALDER IN WALL fqLE13FERWITH 9.3 2 EA CHECK HOLDER SAN JAMAR CK551EA NEC W 1 EA 12 X 4B COUNTER TOP HATCO ORS-4B-D 120 1 5D4 KEC HEAT SEQIF it 2 EA HAND 'M WITH SPI.ASH GCOS PBHS-W-0109- t?6' KEC DIRECT ORAN GUARDS SS R-X IIA 2 EA FAUCET Boos PBF-4SM-5GLF-X Df- x- KEC 12 1 EA GEPATED SANDWCH OEURSO MAMN-W -mw 115 1 YN 11 KEC UNIT 13 1 EA UNDER CIXINIER BEVERAGE iB5 KEC RFFPoGERATOR 14 1 EA HORIZONTAL CUP DISPENSER DISPENSE -RITE AW-1.50 NEC ASE CUSTOMER 15 1 EA PIM C'.'EN STAND EOUIPNER OVEI STAND KEC 15 2 EA CONVEYER PIZZA OVEN TURSOCHEF HHC2420 YHILSS /20 3 40 KEC 17 1 FA POS COUNTER CUSTOM CCS INSTALLED ByCOUENFDCIAL IX151C1N POWER - FOR A]JACEM flXIPMENT 18 1 EA POS SYSTEM TBs V P GC TO COORDINATE POWER AND DATA REQUIREMENTS 18.1 1 LOT POS PRINTER TBS V PARTEC GC TO COORDINATE POWER AND DATA REOUIRENENIS IaA1 EA -ORDER SCN"w - Tas V PATE GC TO COWCWATE POWER AND DATA REQUIREMENTS WALL MOUNITE, 11111 19 1 EA PIZZA OVEN SHROUD- SS CUSTOM KEC SHROUD INST/LIEO BY KEZ - GC TO SHEATH W11H LINED R= VINO FINISH PER FINISH SCHEDULE IS.' 1 EA TYPE N HOOD CUSTOM KEC 20 1 LOT W RE SHELVING BOOS TBS KEC SNELVES NOT TO IXCED T-0' ATF 21 1 EA BVG IN THE BOX TBS 22 1 EA 002 TANK TBs 23 24 1 EA SS WORN TA31E VI/ PREP BOOS ST4R5-3UaSSXSINK tM- KEC IHOIRECT M.191 0 1 EA FACET KROWNE 1A-511L 1ST 1{� NEC 25.1 1 EA FAUCET MOW TGS BRASS 8-0262 KEC 25 1 EA 12 X BB WALL SHOF BOOS EWSS-1295-X NEC GC TO PROVIDE WAl BACKER IN WALL B. 2 EA WALL MOUNT KIT FOCUS FWS14350 KEC DC TO PROVIDE WALL BACKER IN WALL 27 1 EA 3 COMP SINK BOOS 3820304-2D20-X tM' KEC DIglllWN 27. 2 a DUNNAGE RACK NIXED OR2424Z KEC 28 1 EA 5X72 WALL 4WNTE0 ADVANCED TABCO PS-15-M XEC CBACKER IN WALL 31E1F WITH Ear RADI( 29 1 EA PRE -RINSE KROWHE 17-IMM YM' )j' KEC 30 f EA 1SX96 WALL Mt1UflRED AWANCED TABCO PS-IS-95 KEC GC TO PROVIDE WNL BNZ(ER NI WALL SHELF wrrn Por RACX 3/ 2 EA IACNERS N-L P81!HAS NEC REVIEWED FOH COMPLIANCE WITH NFPA 70 - NEC NOV 0 3 2015 City of Tukwila EQUIPMENT LIST I�iYE���liifiiY�Yii���©WIiiY�� lE�WWEIi��©©®Yip W Y�lYiil . m®®®®■■■®■®■■■■mom . a a a m®©®�■■■■■■■■■■® KEC WILL SUPPLY ALL LISTED ITEMS, UNCRATE, SET IN PLACE, THEN ALL MEP CONNECTIONS TO BE DONE BY OTHERS. NO POWER, DRAIN, OR WATER SUPPLY CONNECTIONS WILL BE DONE BY KEC. PLUMBING AND ELECTRICAL INFORMATION FOR REFERENCE ONLY - SEE PLUMBING PERMIT AND ELECTRICAL PERMIT Lo N IV RECEIVED 00 CITY OF TUKWI:.A tz SEP 2 5 2015 W PERMIT CENTER a I DATE I mm V� PIZZA STUDIO Q 00 00 1 co Qa On t11 .3' Lg V 0 IN N n T-1 ICI 00 y�y/1 A� t g00 •-y M M �i N 00 i N C N Vl ~ Date: 8-12-15 Scale: NOTED Drawn by: MIL K2 I ✓ I DATE IINIII t EXISITNG ELETRICAL PANELS 11 GFCI RECEPTACLES SHALL BE PASS & SEYMOUR NO. 2095-W SGID INC. ASSUMES NO RESPONSIBILITY FOR EQUIPMENT CUT SHEET ACCURACY. MANUFACTURER RESERVES THE RIGHT TO REVISE CUT SHEETS WITHOUT NOTIFICATION. VERIFY ALL PRIOR TO INSTALL ALL DIMENSIONS TO BE VERIFIED IN FIELD PRIOR TO EQUIPMENT MANUFACTURING OR ORDERING BY RSC. SGID INC. ASSUMES NO RESPONSIBILITY FOR FIELD DIMENSIONS OR MEP EXISTING CONDITIONS. INFORMATION HAS BEEN PROVIDED TO SGID BY OTHERS AND PLANS REFLECT THAT INFORMATION. ELECTRICAL NOTES 1. THE CONTRACTOR SHALL PROVIDE AND INSTALL STAINLESS STEEL OUTLET AND RECEPTACLE COVERS IN SERVICE AREAS. 2, THE ELECTRICAL CONTRACTOR SHALL PROVIDE POWER TO AND INTERCONNECT ALL REFRIGERATION THERMOSTATS, SOLENOIDS, TIME CLOCKS, DEFROST CIRCUITS, ETC. 3. THE ELECTRICAL CONTRACTOR SHALL CONNECT ALL REMOTE COMPRESSORS AND PROVIDE DISCONNECTS, MAGNETIC STARTERS, AND THERMAL OVERLOAD PROTECTION AS REQUIRED. 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL HEAT TAPE ON DRAIN LINES IN DANGER OF FREEZING. 5. THE ELECTRICAL CONNECTIONS, SPECIFICATIONS AND DIMENSIONS SHOWN ON THESE PLANS ARE FOR FOOD SERVICE EQUIPMENT ONLY. SEE THE DESIGNER'S PLAN SET FOR ALL OTHER ELECTRICAL REQUIREMENTS FOR THIS PROJECT. ELECTRICAL LEGEND H= 115 VOLT DUPLEX OUTLET 0 115 VOLT DCO, DEDICATED/ISOLATED -0- 208 VOLT, SPECIAL OUTLET GD JUNCTION BOX LIGHT FIXTURE/SERVICE MOUNTED ADREURMENSATSPEC'S NCOMMUNICATIONS OWNER $ ON/OFF SWITCH & ALL ELECTRICAL ROUGH -IN WORK AND ALL FINAL CONNECTIONS FOR ALL ITEMS SHOWN AND SPECIFIED ON THESE PLANS SHALL BE PERFORMED BY THE ELECTRICAL CONTRACTOR. 7, UNLESS OTHERWISE SPECIFIED IN THESE PLANS OR OTHER WRITTEN CONTRACTS, IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL -TYPE MATERIALS INCLUDING WRING, SWITCHES, DISCONNECTS, FLEX, CONDUIT, CONTRACTORS, TRANSFORMERS, THERMAL OVERLOAD PROTECTORS, MAGNETIC STARTERS, ELECTRICAL PANELS, CORDS, PLUGS, COVERS, ETC. 8. THE ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECTS AT THE POWER BOX FOR EACH ICE MACHINE HEAD. 9. ALL DIMENSIONS SHOWN ARE FROM GRID LINES, FINISHED WALLS OR FINISHED FLOORS TO CENTER LINE OF ELECTRICAL OUTLET BOXES. HEIGHTS ARE IU TO BE TAKEN FROM CURBS OR PLATFORMS. ROOFTOP EQUIPMENT VERIFY LOCATION WITH ARCHITECTURAL / STRUCTURAL DRAWINGS AND EQUIPMENT SHOP DRAWINGS. HEVIEWEU FuH COMPLIANCE WITH NFPA 70 - NEC City of Tukwila BUILDING DIVISION 10. THE SYMBOLS SHOWN ON THIS PLAN ARE FOR INDICATION OF ROUGH -IN LOCATION AND TYPE OF CONNECTION ONLY. THE ELECTRICAL CONTRACTOR SHALL PROVIDE CIRCUITS AND CONDUIT RUNS AS PER GOOD PRACTICE AND CODE. 11. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FUSED DISCONNECTS FOR EQUIPMENT HOOK-UPS AS REQUIRED BY CODE AND LABELING. 12, ALL GFCI RECEPTACLES SHALL BE LOCATED IN AN ASSESSABLE LOCATION FOR STATIONARY EQUIPMENT, 1n 3. 'GENERAL CONTRACTOR AND SUB CONTRACTORS TO VERIFY ALL EQUIPMENT CUT SHEETS PRIOR r-1 TO ELECTRICAL ROUGH IN AND FINAL CONNECTIONS CV RECEIVED 00 CITY OF TUKWILA tTj SEP 2 5 2015 W PERMIT CENTER a ELECTRICAL INFORMATION FOR REFERENCE ONLY - KITCHEN ELECTRICAL ROUGH IN SEE ELECTRICAL PERMIT SCALE: Y' = 1'.0" + �J PIZZA STUDIO tOUGH IN Date: 8-12-15 Stale: NOTED Drawn by: MIL Job: PIZZA STUDIO TUKWIlA WA K3 V HOME RUN ELECTRIC LLC Page 1 of 2 Washington State Department of Labor Industries HOME RUN ELECTRIC LLC Owner or tradesperson Principals SMITH, MICHAEL, PARTNER/MEMBER SMITH, JESSICA, PARTNER/MEMBER Doing business as HOME RUN ELECTRIC LLC WA UBI No. 602 291 057 License Honne Inicio en Espanol Contact Safety Claims & Insurance PO BOX 217 BOTHELL, WA 98041 425-489-0791 KING County Business type Limited Liability Company Governing persons JESSICA R SMITH MICHAEL T SMITH; Search L&I A-Z Index Workplace Rights Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. .............. I .................. Meets current requirements. License specialties GENERAL License no. HOMERRE974K2 Effective — expiration 05/22/2003— 05/22/2017 Designated administrator ............... SMITH, MICHAEL.T License type Master Electrician Active. Meets current requirements. License no. SMITHMT951 DQ Bond https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602291057&LIC=HOMERRE974K2&SAW= 11/05/2015