Loading...
HomeMy WebLinkAboutPermit EL15-0834 - WESTFIELD MALL / SUITE 712 - RESTAURANT DEMOLITION AND UITILITIES EXTENSIONNVESTFI -jD MALL SUITE 712 21 SOUTHCENTER MALL EL15-0834 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov ELECTRICAL PERMIT Parcel No: 9202470130 Permit Number: EL15-0834 Address: 21 SOUTHCENTER MALL Issue Date: 2/12/2016 Permit Expires On: 8/10/2016 Project Name: WESTFIELD MALL - SUITE 712 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940, CARLSBAD, WA, 92013 Contact Person: Name: GRACE ROBINSON Phone: (206) 720-7001 Address: 2505 THIRD AVE, SUITE 324, SEATTLE, WA, 98121 Contractor: Name: STATIC ELECTRIC INC Phone: (253) 468-3296 Address: 34009 48TH AVE E , EATONVILLE, WA, 98328 License No: STATIEI951C8 Expiration Date: 2/25/2017 Lender: Name: Address: DESCRIPTION OF WORK: DEMOLITION OF AN EXISTING RESTAURANT TENANT SPACE AND EXTEND REQUIRED UTILITIES TO THE FUTURE TENANT SPACE. Valuation of single family: $0.00 Fees Collected: $859.56 Valuation of mf/comm: $31,500.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 �r l Permit Center Authorized Signature:X4���� Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Date: Z-1`z. —20Ik Print Name: Z7�/\ A n e I-- lr) Vl rL�Q This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite l00 Tukwila, HIA 98188 ' http://wwNv.Tukwi]aWA.eov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 920247-0130 Site Address: 21 Southcenter Mall Tenant Name: Westfield Mall, Suite 712 Re -demise PROPERTY OWNER Name: Westfield Southcenter - Address: 2800 Southcenter Blvd. City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Grace Robinson/Craft Architects Address: 2505 3rd Ave., Suite 324 City: Seattle State: WA Zip: 98121 Phone: (206) 720-7001 Fax: (206) 720-2949 Email: Suite Number: 712 Floor: 1 New Tenant: ❑ .....Yes ❑ ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 31,500 Scope of work (please provide detailed information): Demolition of existing tenant space and extend utilities to the future tenant space. Will service be altered? m Yes ❑ No Type of Use: Tvoe of work: ❑ New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms-Applications On Line\2014 ApplicationsWectrical Permit Application Revised 1-1-14.docs Revised: January 2014 bh Adding more than 50 amps? ❑ Remodel ❑ Telecommunication ❑ Yes ❑ No m Tenant Improvement ❑ Temporary Service Page I of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ...........$54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals....................................................................$80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE TANUARY 1, 201.4 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Print Name: (pace Robinson/Craft Architects Mailing Address: 2505 3rd Ave., Suite 324 Seattle, WA 98121 H:\Applications\Forms-Applications On Line\2014 ApplicationsTlectrical Permit Application Revised 1-1-14.docx Revised: January 2014 Ith Date: ! 2= 2! Day Telephone: (206) 720-7001 City State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $694.26 EL15-0834 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $694.26 ELECTRICAL $661.20 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $661.20 TECHNOLOGY FEE $33.06 TECHNOLOGY FEE TOTAL'A.: R000.322.900.04.00 0.00 $33.06 .94 .26 Date Paid: Friday, February 12, 2016 Paid By: STATIC ELECTRIC Pay Method: CREDIT CARD 021916 Printed: Friday, February 12, 2016 1:19 PM 1 of 1 CN?W srsreMs Date Paid: Friday, September 25, 2015 Paid By: WESTFIELD Pay Method: CHECK 05000125 Printed: Friday, September 25, 2015 3:45 PM 1 of 1 RWSY57EM5 INSPECTION RECORD Retain a copy with permit )��`'` 5 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (2.06) 431-367 %� Permit inspection Request Line (206) 438-9350 P �/ I rr VLF Address: 2 Date Called: Special Instructio Date Wanted: C`/� p.m` Requester: Phone No: Project: y ns cc io ®Approved per applicable codes. � Corrections required prior to approval. MENTS: Date: REINSPECTIDIV FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD (� 6�� C Retain a copy with permif L 73VI INSPEC ION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: Date Called: Special Instruction : Date Wanted: �2, a.m p. Requester: Phone No: Approved per applicable codes. 21 Corrections required prior to approval. IInspector: � i9h- (� !Date: 0 3/0Z-II REINSPECtfION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 DIVISION (206) 431-3670 1�-: Ls-©g3q Project: Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: Approved per applicable codes. PC- orrections required prior to approval. COMMENTS: `wit v ►� s /ALA �,�- .BI7z. o� ICA 71o�vS Zv"' doles INSPECTION RECORD Ll= Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project: i _(fe24_L Type opection: ,,-' Address: u ire Z Date Called: Special Instructions: Date Wanted. a.m. "a29✓/ p. m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: �DJt�rAte- ,�^ /' lCw —T oA-,,' •v.D 0 r as ►,- d Jt br u lY t? - '' C .��5 7yttt_ t, �dtTSJ2 d ,a ,n► /!7/L dv v/cv— REINSKCTIQN FEE REQUIRED. Prior to next inspection, fee must be paid 300 Southcenter Blvd., Suite 100. Cat[ to schedule reinspection. J INSPECTION RECORD i Retain a copy with permit INSPECTION NO. PERtvIiT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431.3670 Permit Inspection Request Line (206) 438-9350 Project: ' ` ! ?r Type of Inspegtigp: ` ,� U ��¢l AA Address: 2� Date Called: Special Instructions Date Wanted: a.m. p.m. Requester: J Phone No: EJApproved per applicable codes. 1-1 Corrections required prior to approval. COMMENTS: „ tvi ' 0242-1 ❑ REINSPECTIO1 FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD I Retain a co with permit INSPECTION N0. copy PERMIT N . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection, LO Address: Z/ Date Called: Special Instructions. ' Date Wanted: a rp.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director January 4, 2016 GRACE ROBINSON 2505 THIRD AVE, SUITE 324 SEATTLE, WA 98121 RE: Application No. EL15-0834 WESTFIELD MALL - SUITE 712 21 SOUTHCENTER MALL Dear GRACE ROBINSON: Permit application EL15-0834 for the work proposed at WESTFIELD MALL - SUITE 712 (21 SOUTHCENTER MALL) has not been issued by the City of Tukwila Permit Center. Per the International Building, Residential, and Mechanical Codes as well as the Uniform Plumbing Code and/or the National Electric Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire 3/25/2016. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is completed for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date.. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that your permit is not issued, we do not receive your written request for extension, or your request is denied your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, t L- .ALA Rachelle Ripley Permit Technician File No: EL15-0834 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 Website: TukwilaWA.gov November 10, 2015 City Comment #2 Westfield Mall, Suite 712 — 21 Southcenter Mall Attention: Grace Robinson Correction Letter Response #2 Plan Reviewer: Bill Rambo City of Tukwila Permit # EL15-0834 ELECTRICAL Correction #2, Comment #5 indicates 1200A required, however, transformer secondary conductors are rated at 1005 amps and overcurrent device is shown to have 1000A trip rating. Response: Please see revised drawing E1.0 drawing. Scope of work has been revised to relocating existing service to new location. Secondary transformer and all related electrical provisions to previous scope have been removed. End of City Comment #2 On Behalf of HARGIS ENGINEERS, INC. Brian Safaie CORRECTION LTR#� PL.15-08341 MECEN5 D WN OF 7 UMWV1A City of Tukwila Department of Community Development November 03, 2015 GRACE ROBINSON 2505 THIRD AVE, SUITE 324 SEATTLE, WA 98121 RE: Correction Letter # 2 ELECTRICAL Permit Application Number EL15-0834 WESTFIELD MALL - SUITE 712 - 21 SOUTHCENTER MALL Dear GRACE ROBINSON, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. o CORRECTION/ #2 1.) COMMENT #5 INDICATES 1200 AMPS REQUIRED, HOWEVER TRANSFORMER SECONDARY CONDUCTORS ARE RATED AT 1005 AMPS AND OVER CURRENT DEVICE IS SHOWN TO HAVE 1000 AMP TRIP RATING (AT). Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two_(ZI sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)431-3655. Sincerely, Bill Rambo Permit Technician File No. EL15-0834 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 9 Phone 206-431-3670 • Fax 206-431-3665 October 19, 2015 REVISION #1 Din Tai Fung, Westfield Mall, Suite 712 — 21 Southcenter Mall Attention: Grace Robinson Correction Letter Response #1 Plan Reviewer: Bill Rambo City of Tukwila Permit # EL15-0834 RE-CEiVED ELECTRICAL CITY OF TUK WILA Comment #1: OCT 2 6 2015 Keynotes are not accurate. PERMIT CENTER Response: Please see attached revised sheet E1.0 Comment #2: Provide engineered structural detail for suspended 40001b 500KVA transformer Response: Transformer is revised to floor mount Comment #3: Indicate Service disconnect rating in amperes. Response: Please see attached revised sheet E1.0. (600A13P) C 0n Un"o�!+ Comment #4: LT11# M t�J Specify copper or aluminum conductors. 1 Response: Please see attached revised sheet El.0. (Added note for all conductors shall be copper) Comment #5: 500KVA appears oversized for 1000A. Future considerations? Response: Tenant requires 1200A 2081'120V13phase service. 500KVA transformer is needed to accommodate this requirement. Also, please note, the primary side of transformer is fed with 600A13P End of Revisions#1 On Behalf of HARGIS ENGINEERS, INC. i Brian Safaie j H H A R G I S t: o; i 1: a aveece ome. w„?alai t City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director October 05, 2015 GRACE ROBINSON 2505 THIRD AVE, SUITE 324 SEATTLE, WA 98121 RE: Correction Letter # 1 ELECTRICAL Permit Application Number EL15-0834 WESTFIELD MALL - SUITE 712 - 21 SOUTHCENTER MALL Dear GRACE ROBINSON, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - E DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. CORRECTIONS/ #1 1.) KEY NOTES ARE NOT ACCURATE. SHIFT AT #5. #11 IS MISSING. 2.) PROVIDE ENGINEERED STRUCTURAL DETAILS FOR SUSPENDING A 4000 LB. 500 KVA TRANSFORMER. 3.) INDICATE SERVICE DISCONNECT RATING IN AMPERES (ASSUMING 600A). 4.) SPECIFY COPPER OR ALUMINUM CONDUCTORS (ASSUMING COPPER). 5.) 500 KVA APPEARS OVERSIZED FOR 1000 A 208/120 V SECONDARY. FUTURE CONSIDERATIONS? Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)431-3665. Sincerely, -Ixw*t-�j Bill Rambo2 Permit Technician File No. EL15-0834 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 9 Phone 206-431-3670 9 Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0834 DATE: 11/12/15 PROJECT NAME: WESTFIELD MALL - SUITE 712 SITE ADDRESS: 21 SOUTHCENTER MALL Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 2 Revision # after Permit Issued DEPARTMENTS: �AWC Building Division Fire Prevention Public Works ❑ Structural PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) ❑ Planning Division ❑ ❑ Permit Coordinator 0 DATE: 11/17/15 Structural Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/15/15 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ I'Ing ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0834 DATE: 10/28/15 PROJECT NAME: WESTFIELD MALL - SUITE 712 SITE ADDRESS: 21 SOUTHCENTER MALL Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: (04- Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 10/29/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/26/15 Approved ❑ Approved with Conditions ❑ Corrections Required �— Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) N REVIEWER'S INITIALS: DATE: Permit Center Use Only _ CORRECTION LETTER MAILED:-3 J Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0834 DATE: 09/25/15 PROJECT NAME: WESTFIELD MALL - SUITE 712 SITE ADDRESS: 21 SOUTHCENTER MALL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS:Q Building Division a Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 09/29/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/27/15 Approved ❑ Approved with Conditions ❑ Corrections Required Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only r CORRECTION LETTER MAILED: Departments issued corrections: Bldg'&V Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 4100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://14,wti4;.ci.tztkm,ila.l4,a.tis V. III®�T' �IJl�IITTA,IJ Revision submittals must be submitted in person at the Perinit Center. Revisions will not he accepted through the mail, fax, etc. Date: ( Iq/762 J C, Plan Check/Permit Number: ❑ Response to Incomplete Letter # ® Response to Correction Letter # 2 ❑ Revision # after Permit is Issued ❑ Revision requested. by a City Building Inspector or Plans Examiner Project Name: Westfield Mall — Suite 712 Project Address: 21 Southeenter Mall Contact Person: Summary of Revision: Phone Number: Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: _ 1�v I'SI---Entered in TRAKiT on EL15-0834 �'V 1: � � WV 1•ii: \applications\fomis-applications on line\revision submittal Created: 8-13-2004 Revised: City of Tukwila Department of Community .Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: h1W://www.ci.tukwi1a.wa.us REVISION SUBMITTAL . Revision st:bmittals must be srsbmitted irrFersor+ nt the Permit Center. Revis.-ons will not be aceepled through the mail, fax, etc. Date: Plan Check/Permit Number: EL 15-0834 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ASCSIM MY OF TUKWItA Project Name: Westfield Mall — Suite 712 OCT 2 6 2015 PFFiMT 4,5NTEP Project Address: 21 Southcenter Mall Contact Person:SA,, Phone Number: Summary of Revision: ly Sheet Number(s): "Cloud" or highlight all areas of revision including date Received at the City of Tukwila Permit Center by ❑ Entered in TRAKiT on \applications\fomis-applications on line\revision submittal Created: 8-13-2004 Revised: STATIC ELECTRIC INC Page I of 2 Hoene t:ispaiiol Contact Safety & Health (0 Washington State Department of Labor & Industries STATIC ELECTRIC INC Search L&I A-Z Index Help My Secure l: `�I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 34009 48th Ave E EATONVILLE, WA98328 Principals 253-4683296 JOHNSON, SHANE E, PRESIDENT PIERCE County JOHNSON, SHANE E, AGENT Doing business as STATIC ELECTRIC INC WA UBI No. Business type 602 455 807 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. STATIEI951 C8 Effective — expiration 02/25/2005— 02/25/2017 Designated administrator JOHNSON,SHANE License type Electrical Administrator Bond- .......... .... DEVELOPERS SURETY & INDEM CO Bond account no. 574726C Received by L&I 02/28/2005 Savings ............... _. No savings accounts during the previous 6 year period. License Violations ........................................................ No license violations during the previous 6 year period. Workers' comp Active. Meets current requirements. License no. JOHNSS`973PH $4,000.00 Effective date 02/17/2005 Expiration date Until Canceled Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 131,984-01 ..... _.......................... Doing business as STATIC ELECTRIC INC https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602455807&LIC=STATIEI95 l C8&SAW= 2/12/2016 rn 3 v, O Lv I L�. 0 i 0 U L0 LO i Ln i m 0 i m a CL W o L. Z o a Ld CL Q LR Ld z M J !9 LL rn 0 ABBREVIATIONS 1 ELECTRICAL GENERAL NOTES 2 SYMBOL LEGEND 3 AFF ABOVE FINISH FLOOR DEMOLITION NOTES GENERAL NOTES: FIRE ALARM BIDDER DESIGN GENERAL NOTE: SINGLE POLE TOGGLE SWITCH, 20AMP, 120/277 VOLT, � @ 48" UON UNLESS NOTED AHJ AUTHORITY HAVING OTHERWISE. ALL SWITCHES USED AS MOTOR DISCONNECTING ME MEANS SHALL BE HP RATED. 1. IN THE EVENT OF TEMPORARY FIRE ALARM REQUIRED BY LANDLORD AND/OR AHJ, THIS SYSTEM JURISDICTION 1. THE ENTIRE SCOPE OF THE DEMOLITION WORK MAY NOT BE SHOWN ON THE 1. ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH LOCAL AND NATIONAL CODES. (3 = 3 WAY SWITCH / 4 = 4 WAY SWITCH) AWG AMERICAN WIRE ELECTRICAL PLANS. PRIOR TO BID, THE ELECTRICAL SUB -CONTRACTOR SHALL: ALL POWER WIRE ON THE PREMISE SHALL BE INSTALLED IN CONDUIT. CONDUCTOR SHALL BE INSTALLED PER LANDLORD AND/OR AHJ REQUIREMENTS . FIRE ALARM SYSTEM SYSTEM GAUGE a. REVIEW THE ENTIRE SET OF TENANT IMPROVEMENT PLANS, INCLUDING THE INSULATION SHALL BE THW, THHN OR THWN. NO ROMEX CABLES ARE ALLOWED. SHALL BE A BIDDER DESIGN SYSTEM AND SHALL BE PROVIDED AT THE EXPENSE OF ELECTRICAL #o DEVICE TO BE DEMOLISHED. REFER TO DEMOLITION NOTES. ARCHITECTURAL AND MECHANICAL TO FULLY UNDERSTAND THE SCOPE OF WORK. 2. ALL ELECTRICAL MATERIALS SHALL BE NEW AND UNUSED AND SHALL INCLUDE ALL SUB -CONTRACTOR. E.C. SHALL PROVIDE TEMPORARY FIRE ALARM SYSTEM IN ACCORDANCE WITH BKBD BACKBOARD BLDG BUILDING REPORT BACK TO THE GENERAL CONTRACTOR WITH ANY DISCREPANCIES THAT MAY OPTIONAL ITEMS REQUIRED FOR A COMPLETE INSTALLATION. ALL EQUIPMENT SHALL THE REQUIREMENTS OF THE AHJ AND LANDLORD, INCLUDING SUBMITTAL FOR PERMIT. THE BIDDER ® ELECTRICAL TRANSFORMER EXIST. BEAR THE UNDERWRITER'S LABORATORIES LABEL. DESIGN CONTRACTOR SHALL DETERMINE THE EXACT REQUIREMENTS FOR THE SYSTEM C CONDUIT b. VISIT THE SITE AND REVIEW THE TENANT PREMISES WITH THE GENERAL CONTRACTOR 3. BX, ROMEX, ARMORED CABLING, ETC. SHALL NOT BE ALLOWED. SEE SPECIFICATIONS INCLUDING QUANTITY OF DEVICES AND ANY ACCESSIBILITY REQUIREMENTS WITH THE A.H.J. JUNCTION BOX, SIZE & TYPE AS INDICATED OR AS REQUIRED CB CIRCUIT BREAKER CKT CIRCUIT AND LANDLORD TO FULLY UNDERSTAND THE SCOPE OF WORK AND EXISTING FOR USE OF MC CABLING. 2. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF THE PROPOSED FIRE ALARM SYSTEM, CCEILING CONDITIONS. REPORT BACK TO THE GENERAL CONTRACTOR WITH ANY DISCREPANCIES 4. ELECTRICAL CONTRACTOR SHALL PROVIDE PULL STRING IN ALL CONDUITS. INCLUDING ALL DEVICES AND WIRING LAYOUTS, (IN PLAN FORM), TO THE FIRE MARSHAL AND ) o FLOOR OUTLET POKE -THROUGH DEVICE. PRIOR TO CORING THE FLOOR. COORDINATED WITH CO CONDUIT ONLY THAT MAY EXIST. 5. ALL LOW VOLTAGE CABLING SHALL BE IN CONDUIT IF REQUIRED BY THE AHJ OR LANDLORD FOR APPROVAL PRIOR TO SUBMITTING TO ENGINEER FOR REVIEW. ANY REVISIONS CONTR CONTRACTOR c. REVIEW THE SCOPE OF WORK OF ALL OTHER DISCIPLINES AND TRADES TO FULLY LANDLORD U.O.N. AND/OR ADDITIONS REQUIRED BY THE LOCAL JURISDICTION PRIOR TO OBTAINING CERTIFICATE OF LANDLORD AND PROVIDE XRAYING OF FLOOR. CT CURRENT TRANSFORMER UNDERSTAND THEIR SCOPE AND THE IMPACT ON THE ELECTRICAL SYSTEMS. 6. ELECTRICAL SUB -CONTRACTOR SHALL PROVIDE HEAVY DUTY PULL WIRE TO OCCUPANCY ARE THE RESPONSIBILITY OF THE CONTRACTOR AND WILL NOT BE REASON FOR e- 20 AMP 125V 3W SIMPLEX RECEPTACLE, 18" LION CU COPPER 2. THE ELECTRICAL SUB -CONTRACTOR SHALL INCLUDE IN THE BID PROPOSAL THE COST ACCESSIBLE TENANT CEILING AREA FOR ALL TELECOMMUNICATIONS AND LOW ADDITIONAL COMPENSATION TO THE CONTRACTOR. @ FOR ALL WORK REQUIRED TO ACCOMMODATE THE DEMOLITION SCOPE OF WORK, VOLTAGE CONDUITS AND OUTLETS. 20 AMP 125V 3W DUPLEX RECEPTACLE, @ 18" LION DIST DISTRIBUTION DS DISCONNECT SWITCH INCLUDING THE INFORMATION SHOWN ON THE TI PLANS, INFORMATION DISCOVERED 7. ALL EXTERIOR AND ROOF RECEPTACLES SHALL BE WEATHER PROOF AND GFCI. 20 AMP 125V 3W DOUBLE DUPLEX RECEPTACLE, @ 18" LION(E) DURING THE SITE REVIEW, AND AS REQUIRED TO ACCOMMODATE THE TENANT 8. E.C. SHALL PROVIDE ALL SUPPORTS, CLIPS, POWER CONNECTIONS, TRIMS, SEISMIC DENOTES EXISTING DEVICE/EQUIPMENT IMPROVEMENT AND TO COMPLY WITH THE CODES/AHJ REQUIREMENTS. BRACING AND ETC., AS REQUIRED TO COMPLETE A LIGHTING SYSTEM. TO REMAIN 3. MAINTAIN SERVICE TO ALL EXISTING SYSTEMS AND EQUIPMENT/DEVICES THAT ARE NOT 9. E.C. SHALL EVALUATE AND VERIFY EXISTING CONDITIONS WITH DEMOLITION AND NEW COMMUNICATION OUTLET MOUNTED AT 18" AFF., UNLESS NOTED OTHERWISE. PROVIDE EC ELECTRICAL SCHEDULED TO BE DEMOLISHED, THAT ARE NECESSARY FOR NORMAL OPERATIONS, WORK PLANS PRIOR TO STARTING ANY SCOPE, AND REPORT BACK TO G.C. IF SINGLE GANG MUD RING WITH CONDUIT STOPPING 6" FROM THE OPENING TO PROVIDE SUB -CONTRACTOR THAT DO NOT CONFLICT WITH THE NEW CONSTRUCTION OR THE INTENDED USE OF THE DISCREPANCIES ARE ACKNOWLEDGED AND VERIFY ACCEPTABLE SOLUTION PRIOR TO AMPLE BENDING RADIUS. ALL ROUGH -INS FOR SINGLE WALL OUTLET SHALL BE 3/4" EMT, SPACE, AND THAT ARE REQUIRED BY THE LANDLORD OR OTHER TENANTS TO REMAIN IN DEMOLISH, ROUGH -IN, INSTALLATION AND ETC. STUBBED TO ACCESSIBLE CLG. AT TENANT SPACE. EF EXHAUST FAN EL EMERGENCY LIGHT PLACE. RELOCATE EQUIPMENT TO MAINTAIN SERVICES IF NECESSARY TO 10. PROVIDE INSULATED BUSHING ON ALL LOW VOLTAGE CONDUIT ENDS. ELEC ELECTRICAL ACCOMMODATE RENOVATION. 11. E.C. IS RESPONSIBLE TO VERIFY VOLTAGES PRIOR TO ROUGH -IN. ❑+ NON -FUSED DISCONNECT SWITCH SIZED PER NEC EM EMERGENCY 4. UNLESS NOTED OR DIRECTED OTHERWISE, THE ELECTRICAL SUB -CONTRACTOR SHALL 12. FIRE SEAL ALL FIRE WALL PENETRATIONS FOR CONDUITS WITH AN APPROVED FIRE EQUIP EQUIPMENT PROVIDE THE DEMOLITION FOR ALL EXISTING ELECTRICAL DEVICES/ EQUIPMENT, SEALANT AFTER CONDUIT INSTALLATION. FIRE SEAL SHALL PROVIDE EQUAL FIRE 0 FUSED DISCONNECT SWITCH, SIZE PER UNIT LABEL, PER NEC ETR EXISTING TO REMAIN BRANCH CIRCUITING, LOW VOLTAGE CABLING, UNUSED CONDUIT, ETC., FROM WITHIN RATING AS WALL. EUH ELECTRIC UNIT HEATER THE TENANT PREMISES. PRIOR TO DEMOLITION, COORDINATE WITH THE GENERAL 13. CONTRACTOR SHALL PROVIDE AND INSTALL ALL JUNCTION AND PULL BOXES REQUIRED 19 EQUIPMENT CONNECTION EWC ELECTRIC WATER COOLER EXIST EXISTING CONTRACTOR AND ARCHITECTURAL TO FULLY UNDERSTAND THE SCOPE AND FOR THE INSTALLATION OF ELECTRICAL DEVICES AND EQUIPMENT WHETHER OR NOT [ LIGHT LINE WEIGHT INDICATES EXISTING ELECTRICAL FACP FIRE ALARM CONTROL SEQUENCE OF THE DEMOLITION. ADJUST DEMOLITION WORK TO ACCOMMODATE THE SPECIFICALLY INDICATED ON THE PLANS. SIZING OF THE BOXES SHALL BE PER NEC. PANEL SEQUENCE DICTATED BY THE GENERAL CONTRACTOR AND ARCHITECTURAL. 14. CONTRACTOR SHALL CONSULT AND ADAPT BUILDING STANDARD DOCUMENTS/RULES - - - CONDUIT RUN CONCEALED BELOW FLOOR OR FINISHED GRADE OR IN FLOOR GND GROUND 5. PRIOR TO DEMOLITION, COORDINATE WITH THE GENERAL CONTRACTOR AND LANDLORD AND PROVIDE IN ACCORDANCE WITH N.E.C. AND A.H.J. UNDERLAYMENT GFI GROUND FAULT CIRCUIT TO DETERMINE IF ANY DEMOLISHED MATERIALS (SUCH AS LIGHT FIXTURES) ARE 15. REFER TO CONTRACTOR RULES AND REGULATIONS FOR BUILDING SPECIFIC CONDUIT CONCEALED IN CEILING OR WALL INTERRUPTER REQUIRED TO BE TURNED -OVER TO THE LANDLORD. IF SO, TURN -OVER SUCH ELECTRICAL REQUIREMENTS. CONTRACTOR SHALL ACCOMMODATE ALL BUILDING HOA HAND/OFF/AUTOMATIC HP HORSEPOWER MATERIALS AS REQUESTED. OTHERWISE PROVIDE THE PROPER DISPOSAL OF ALL RULES AND DESIGN CRITERIA STANDARDS. CONDUIT WITH WIRING RUN CONCEALED IN OR ABOVE CEILING OR WALL, OR RUN EXPOSED H TR HEATER TR DEMOLISHED MATERIALS. 16. ALL FLEXIBLE CONDUITS SHALL BE ROUTED CLOSE TO STRUCTURAL DECK AND IN -LINE / \ IN UNFINISHED AREAS. 6. IN THE EVENT ELECTRICAL SYSTEMS ARE WRONGLY DEMOLISHED OR BROKEN DUE TO WITH CEILING GRID. JUNCTION BOX THE DEMOLITION WORK, ELECTRICAL SUB -CONTRACTOR SHALL REPAIR SUCH SYSTEMS 17. ALL FLEXIBLE CONDUITS, UNLESS OTHERWISE APPROVED BY LANDLORD/OWNER, MUST / CONDUIT WITH WIRING RUN CONCEALED BELOW FLOOR. LTG LIGHTING AS REQUIRED TO RETURN SYSTEM TO PROPER OPERATIONAL STATE. BE KEPT AT A MAXIMUM OF 18" FOR EQUIPMENT. IT IS APPROVED TO HAVE J-BOXES, ON LTS LIGHTS LV LOW VOLTAGE 7. IN THE EVENT OF DEMOLISHING ENTIRE AREA CEILING GRID AND/OR LIGHT FIXTURES, THE HOMERUN CONDUIT, ABOVE EACH OFFICE AND RUN FLEX CONDUIT TO WALL PLUGS, O CONDUIT ALL LIGHTING SHALL BE TEMPORARY SUSPENDED UNLESS PERMITTED BY LANDLORD. SWITCHES, LIGHTS, ETC. RISER - UP OR DOWN MCB MAIN CIRCUIT BREAKER 8. COORDINATE DEMOLITION WORK WITH GENERAL CONTRACTOR. 18. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR EXACT LOCATION OF MLO MAIN LUGS ONLY 9. THROUGHOUT CONSTRUCTION, MAINTAIN CONTINUITY OF ALL ELECTRICAL AND LOW EQUIPMENTS. F - -0_1 LIGHT FIXTURE. SEE LIGHTING FIXTURE SCHEDULE FOR DESCRIPTION (a) LIGHT FIXTURE MT EMPTY CONDUIT WITH VOLTAGE WIRING AND SERVICES TO ALL ITEMS WHICH ARE REQUIRED FOR 19. ALL CONDUIT ROUTING PATHS SHOWN ARE SYMBOLIC. ACTUAL PATH MAY DIFFER. SWITCHING DESIGNATION PULLSTRING CONSTRUCTION OR FOR THE OPERATION OF LIFE SAFETY, OTHER ACTIVE TENANT, OR PRIOR TO ROUGH -IN, COORDINATE AND VERIFY CONDUIT ROUTING PATH WITH MTD MOUNTED MTG HGT MOUNTING HEIGHT FOR BUILDING OPERATIONS. ANY REQUIRED INTERRUPTION OF THESE SERVICES SHALL ARCHITECT AND BUILDING OPERATION MANAGER. 49 A SOLID COLOR DENOTES EMERGENCY LIGHT FIXTURE. BE FULLY COORDINATED WITH THE GENERAL CONTRACTOR. 20. REFER TO CONTRACTOR RULES AND REGULATIONS FOR BUILDING SPECIFIC N NORMAL (N) DENOTES NEW 10. ALL EXISTING ELECTRICAL EQUIPMENT INDICATED TO BE REMOVED SHALL HAVE ALL ELECTRICAL REQUIREMENTS. CEILING OR WALL MOUNTED EXIT SIGN. PROVIDE HOT, UNSWITCHED CIRCUIT TO LIGHT EQUIPMENT/DEVICE SERVING BRANCH CIRCUIT WIRING AND LOW VOLTAGE CABLING FULLY REMOVED BACK 21. THIS CONTRACTOR SHALL PROVIDE TEMPORARY CONSTRUCTION POWER AND LIGHTING FIXTURE (DIRECTIONAL CHEVRONS AS REQUIRED) NL NIGHT LIGHT TO POINT OF SERVICE WHICH REMAINS. EXISTING CONDUIT SHALL BE FULLY REMOVED AS DIRECTED BY OWNER AND/OR THE GENERAL CONTRACTOR. HE SHALL INCLUDE IN NF NON -FUSED BACK TO POINT WHERE CONFLICT WITH NEW CONSTRUCTION IS FULLY ELIMINATED. HIS BID PROVING TEMPORARY LIGHT FIXTURES, EXIT SIGNS, AND EMERGENCY EGRESS BATTERY POWERED EGRESS LIGHT, TYPE AS SCHEDULED NIC NOT IN CONTRACT 11. ALL EXISTING PANEL -BOARDS WHICH ARE AFFECTED BY THIS PROJECT SHALL BE LIGHTING FOR TEMPORARY EXIT AND CORRIDORS AS REQUIRED BY THE LOCAL PFB PROVIDE FOR FUTURE BREAKER THOROUGHLY CLEANED. PROVIDE NEW TYPED PANEL DIRECTIONS ACCURATELY INDICATING ITEMS SERVED BY EACH CIRCUIT. BUILDING CODE AND BUILDING STANDARDS. ® © SHEET NOTE REFERENCE PB PULLBOX 12. ALL EXISTING LOW VOLTAGE CABLING NOT REQUIRED TO REMAIN FOR OPERATION OF PNL PANEL PWR POWER LIFE SAFETY, OTHER ACTIVE TENANTS OR FOR BUILDING OPERATIONS. CABLES SHALL SECTION DESIGNATION: TOP LETTER INDICATES SECTION, BE REMOVED IN ACCORDANCE WITH THE N.E.C.; CABLES SHALL NOT BE LEFT E1 BOTTOM LETTER/NUMBER INDICATES SHEET a (R) DENOTES DEVICE/ ABANDONED. EQUIPMENT TO BE RELOCATED 13. THE E.C. SHALL REMOVE EXISTING LIGHTING CONTROLS FOR THIS SPACE AND REPLACE e DETAIL DESIGNATION: TOP NUMBER INDICATES DETAIL, WITH NEW SYSTEM AS SPECIFIED. E.C. SHALL PROVIDE ALL MODIFICATIONS TO E1 BOTTOM LETTER/NUMBER INDICATES SHEET REC RECEPTACLE EQUIPMENT, FEEDERS, AND BRANCH CIRCUITING TO ACCOMMODATE THE NEW WORK XX S OR SW SWITCH AND INSTALLATION OF NEW EQUIPMENT AND LIGHTING CONTROLS. E.C. SHALL PROVIDE MECHANICAL & PLUMBING EQUIPMENT DESIGNATION SIG SIGNAL ALL LIGHTING CONTROLS REQUIRED TO COMPLY WITH CODE. X SMR SURFACE METAL RACEWAY 14. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR EXTERIOR DEMOLITION SCOPE. (E) DENOTES EXISTING EQUIPMENT/DEVICE, SCHEDULED TO REMAIN SPKR SPEAKER 15. ALL CORE -DRILLING SHALL BE COORDINATED WITH THE LANDLORD AND SHALL BE SS SAFETY SWITCH PERMITTED AT THE TIME OF DAY ALLOWED BY THE LANDLORD AND G.C., IN ADDITION, (N} DENOTES ELECTRICAL CONTRACTOR PROVIDE NEW STA STATION FLOOR X-RAY OR ULTRASOUND REQUIRED. (R) DENOTES RELOCATED EXISTING EQUIPMENT/DEVICE TEL TELEPHONE TRANS TRANSFORMER (ER) DENOTES EXISTING EQUIPMENT/DEVICE TO BE RELOCATED TTB TELEPHONE BACKBOARD ELECTRICAL PRE -BID SITE REVIEW: ELECTRICAL FIRE ALARM COMBINATION AUDIBLENISUAL UNIT, WALL MOUNTED, TYP TYPICAL 80' AFF TO BOTTOM OF STROBE LENS 1. PRIOR TO CONSTRUCTION, VISIT PROJECT SITE AND REVIEW ALL AREAS OF THE TENANT UG UNDERGROUND UH UNIT HEATER SPACE, INCLUDING BUT NOT LIMITED TO, BACKROOMS, UNOCCUPIED SPACES AND - QF FIRE ALARM PULL STATION, 48" A.F.F. REVISIQNS LION UNLESS OTHERWISE ABOVE CEILING AREAS TO IDENTIFY THE FOLLOWING ITEMS WHICH MAY NOT TO SHOWN O SMOKE DETECTOR No changes shall be made to the scope NOTED ON THE PLANS: of worl( k^fithout prior approval of V VOLTAGE 1.1. EXISTING ELECTRICAL EQUIPMENT THAT MUST BE REMOVED AND/OR RELOCATED ENZ FIRE ALARM VISUAL DEVICE Tjj1.j^r'i!3 Building Division. VP VA POR PROOF TO ACCOMMODATE THE NEW WORK. RACEWAY N'071 w �i��zs will require plan submittal F- -�$ FIRE SMOKE DAMPER itre a new 1.2. EXISTING BRANCH CIRCUITS, ELECTRICAL FEEDERS, AND ASSOCIATED and may ir1CiUGe additional plan review fees. W WATT OR WIRE WHICH ARE NOT SCHEDULED FOR REMOVAL, BUT WILL REQUIRE MODIFICATION TO W/ WITH WP WEATHERPROOF ACCOMMODATE THE NEW WORK. WT WATERTIGHT 1.3. EXISTING CABLING AND RACEWAYS FOR LOW VOLTAGE SYSTEMS WHICH ARE NOT NOTE: SYMBOLS INDICATED ABOVE MAY NOT NECESSARILY SCHEDULED FOR REMOVAL, BUT WILL REQUIRE MODIFICATION TO ACCOMMODATE APPEAR AS PART OF THESE DRAWINGS IF NOT REQUIRED. XFMR TRANSFORMER THE NEW WORK. 2. INCLUDE THE COSTS ASSOCIATED WITH: 2.1. REMOVING AND/OR RELOCATING EXISTING ELECTRICAL EQUIPMENT TO ACCOMMODATE NEW WORK. INCLUDE COST ASSOCIATED WITH EXTENDING ASSOCIATED CONDUCTORS, CABLING AND RACEWAY TO MAINTAIN EQUIPMENT FULLY OPERATIONAL. 2.2. MODIFYING AND REPLACEMENT (WITH NEW AS REQUIRED) OF EXISTING BRANCH CIRCUITS AND ELECTRICAL FEEDERS TO MAINTAIN CONTINUITY OF CIRCUITS/COSTS REVIEWED ASSOCIATED WITH RE -SUPPORTING AND REPLACEMENT (WITH NEW AS REQUIRED) OF ASSOCIATED RACEWAY. .FOR 5 R '�;nATE P! r �JiIT COMPLIANCE WITH 2.3. MODIFYING AND/OR REPLACEMENT (WITH NEW) OF EXISTING LOW VOLTAGE i` QRED FOR: NFPA 70 - NEC SYSTEM SYSTEM CABLING TO MAINTAIN CONTINUITY OF CABLING TO EQUIPMENT NOT SCHEDULED FOR REMOVAL. THIS SHALL INCLUDE RE -SUPPORTING AND C�knechanical DEC 0 2 2015 REPLACEMENT (WITH NEW AS REQUIRED) OF CABLE AND ASSOCIATED RACEWAY. ❑ Mcctrical SPLICING OF LOW VOLTAGE SYSTEM CABLE IS NOT ACCEPTABLE. , 3. NOTIFY OWNER'S CONSTRUCTION MANAGER OF ANY ADDITIONAL COSTS ASSOCIATED u R bing WITH EXTRA WORK AS A RESULT OF THE ELECTRICAL PRE -BID SITE REVIEW. C116as Piping pity ofTuRWErI BUILDING DIVISION '3'V of Tukwila F°u". r"" G DIVISION FILE COPY z-ermat No. li�ks�- 0 Bill w � r Pla:l raview approval is subject to errors and ornissions. R ` LE:D f ;3roval of-onstruction documents does not authorize DI ' i Div "� i� W l l_ t' violG'.icn of any adopted code or ordinance. Receipt p OCT 2 C, 2015 a L-n- ro,m-d ..=old Copy and conditions is acknowledged: PERMIT CENTER Date: ZZo f !- City of TAwrila BUILDING DIVISION %OWSOUTHCENTERL Cp -�r arch sects 2505 Third Avenue Suite 324 Seattle, WA 98121 206.720.7001 phone 206.720.2949 fax www.craftarchitects.com z W Q � z W W LLJ Q o0 00 I � 77 LLzw� W ::D n' lr 7 Q Q L.LJ LL_ Q U .. Q 0 c W o r- lr N 0 V ! Z Q 1011 Y/l S" Submittals/Revisions: !NOI 10/211 Sheet Title: ELECTRICAL NOES & LEGEND Date: 091 M5 Design: BC Drawn: ova Project No: 15-19 Approved: 15-145 Building No: KMC Sheet No: E 0,, 1 1%A0VP1rJ.IT 1VArT ®QruITrrTc 9tNR Q (ER) P (R) MSBA SCALE: 1 /8" = 1'-0" ELECTRICAL LIGHT FIXTURE SCHEDULE BALLAST/ TYPE FIXTURE TYPE LAMPS VOLTS WATTS DESCRIPTION DRIVER A ELEC LITHONIA; Z132MV (1)32W T8 120/277 32 4' STRIP LIGHT FIXTURE EM ELEC LITHONIA; EUD-LED-M12 LED 120/277 1.8 EMERGENCY LIGHT FIXTURE. EXIT/EMERGENCY COMBO. PROVIDE PROPER LETTER/FINISH EX ELEC LITHONIA; E*-LED-M6 LED 120/277 3.2 PER AH1. RTURTU UDS LOAD ENTE B RTU 3 I EXISTING SERVICE LATERAL TO BE EXTENDED TO NEW L_ LOCATION OF RELOCATED SWITCHBOARD LOAD ENTEI A 200A SPARE RTU] a q asov' XFMR X T-LD-K1 LT12208Y 225KVA ov LD-K1 208/120 800A LP -K2 LP-K1A LP-K1 208/12BAR 0 208/120 208/120 NONE (E) FOUR (4) 3.5"C., 4#350MCM, 1#3/0 GND— UTILITY TRANSFORMER 480Y/277 (E) FOUR (4) 3.5"C., 4#350MCM, 1#3/0 GND (E)1200A/3P )METER (E)400A� (E)400A� 480V I XFMR X X T-LD-1 225KVA LT208Y LD-1 208/120 800A LP-1 I LP-1A 208/120 208/120 MECHANICAL LOADS HP-1 I HP-1A 480/277 480/277 (ER)MSB-1 MAIN SWBD 1200A, 480Y/277 (E)200A� 200A SPARE LP-2 LP-3 208/120 208/120 , UTILITY TRANSFORMER 480Y/277 44 J (E)1200A/3P M (E)METER 0 SHOW PUMP ROOM 119 HP-1 480/277 ILT-18 LP-4 '.08/277 208/120 REVIEWED HUH COMPLIANCE WITH NFPA 70 - NEC DEC 0 2 2015 City of -Tukwila � I BUILDING DIVISION � (R)MSB-1 MAIN SWBD 1200A, 480Y/277 i T T T T T T (E)60 (E)60 (E)60 (E)60 200A (E)400A SPARE (E)400A 200A l � (E)400A� (E)200A� SPARE (E)40 (E)40 (E)40 (E)40 (E)400A (E)400A® (E)400A® (E)200A® SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE — 3 POWER DISTRIBLMON DIAGRAM E1.o NONE CORRE TION LTR# GENERAL NOTES: 1. PROVIDE DEDICATED NEUTRAL PER CIRCUIT. 2. ALL TRENCHING AND CONDUIT PATHS SHALL BE COORDINATED WITH BUILDING/FACILITY OPERATIONAL MANAGER. 3. EXIT SIGNS AND EMERGENCY LIGHT FIXTURES SHALL BE CONNECTED TO AN UNSWITCHED HOT CONDUCTOR AHEAD OF ANY OCCUPANCY SENSORS, SWITCHES OR CONTACTORS. 4. COORDINATE MOUNTING METHOD OF LIGHT FIXTURES AND EXIT SIGN WITH BUILDING OPERATIONAL MANAGER. #� KEY NOTES: 1. (1) 2" CONDUIT WITH PULL STRING FROM LANDLORD MPOE TELEPHONE BACKBOARD STUBBED TO TENANT SPACE MINIMUM OF 12'-0" A.F.F. FOR LOW-VOLTAGE/TELECOMMUNICATION SERVICE FEED. COORDINATE WITH LANDLORD FOR ROUTING AND LOCATION OF MPOE. 2. PROVIDE (1) 1" CONDUIT WITH PULL STRING FROM LANDLORD FIRE ALARM PANEL STUBBED TO TENANT SPACE AT MINIMUM OF 12'-0" A.F.F. FOR TENANT INTERCONNECT.. 3. EXISTING 120/208V/30/4W 150AMP HOUSE PANEL'S700'. FIELD COORDINATE EXACT LOCATION PRIOR TO START OF WORK. 4. EXTEND AND ADJUST THE EXISTING SERVICE LATERAL TO TERMINATE AT THE NEW LOCATION OF SERVICE EQUIPMENT. PROVIDE TRENCHING FROM EXISTING LOCATION TO NEW LOCATION. PROVIDE NEW CONDUIT AND CONDUCTORS AS NECESSARY TO PROVIDE A COMPLETE AND CODE COMPLIANT SERVICE. 5. RELOCATED EXISTING SERVICE ENTRANCE/METER. COORDINATE WITH THE LANDLORD FOR THE EXACT LOCATION FOR THIS EQUIPMENT. COMPLY WITH CODE AND THE LOCAL UTILITY COMPANY REQUIREMENTS. PROVIDE CONCRETE PAD. Q 6. PROVIDE MANUAL CONTROL SWITCH TO OVERRIDE VACANCY SENSORS IN TENANT SPACE. COORDINATE FINAL LOCATION WITH BUILDING OPERATIONAL MANAGER. LOCATE ADJACENT TO ENTRY DOOR. 7. CONNECT TO SPARE 20A/1P BREAKER IN EXISTING HOUSE PANEL'S700'. PRIOR TO ROUGH -IN, COORDINATE CONDUIT ROUTING PATH WITH BUILDING OPERATIONAL MANAGER. 8. ALL EXIT AND EMERGENCY LIGHTING TO BE CONNECTED TO NORMAL LIGHTING IN THE SAME AREA THE EXIT/EMERGENCY LIGHT IS LOCATED CIRCUIT PER CODE, AHEAD OF SWITCH. ALL EMERGENCY UNITS HAVE BATTERY BACKUP. 9. EXISTING ELECTRICAL ROOM TO BE DEMOLISHED. REMOVE ALL EQUIPMENTS)/ELECTRICAL PROVISION(S), UNLESS NOTED OTHERWISE. SEE ELECTRICAL RISER DIAGRAMS ON THIS SHEET. REFER TO SHEET E0.1 FOR ADDITIONAL DEMOLITION AND SITE REVIEW NOTES. e 1 ° i° «r } 2505 Third Avenue Suite 324 Seattle, WA 98121 206.720.7001 phone 206.720.2949 fax www.craftarchitects.com z W Q � z w 00 Imo- C� � �- = 2: (-1'� W V- Lij z � O w 3�: LL_ Q U ., = < �- ry z �' 0 r) O C/) W o � r N 0 z Q 1 CONSULTANT �WIS RECEIVED CITY OF TUKWILA NOV 12 2015 PERMIT CENTER Submittals/Revisions: Sheet Title: ELECTRICAL PLAN Date: WI I2015 Design: MRD Drawn: AO Project No: 15-145 Approved: BM Building No: El,,0Sheet No: PnOV004T r*0ArT AQrWITGrTC onk