Loading...
HomeMy WebLinkAboutPermit EL15-0899 - WASHINGTON PLACE / INTERURBAN HOTEL - POWER AND LIGHTING FOR BUILDINGWASHINGTON PLACE BUILDING 223 ANDOVER PARK E ELl 5=0899 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 0223100090 Permit Number: EL15-0899 Address: 223 ANDOVER PARK E Issue Date: 12/10/2015 Permit Expires On: 8/14/2018 Project Name: WASHINGTON PLACE - BUILDING Owner: Name: WASHINGTON TOWERS LP Address: 18230 E VALLEY HIGHWAY #195 , KENT, WA, 98032 Contact Person: Name: LEN WHALEN Address: 6412 S 196 ST, KENT, WA, 98032 Contractor: Name: E C COMPANY Address: PO BOX 10286, PORTLAND, OR, 97296 License No: ECCOM**148BA Lender: Name: Address: DESCRIPTION OF WORK: Phone: (206) 436-6048 Phone: (503) 224-3511 Expiration Date: 6/30/2018 ELECTRICAL POWER AND LIGHTING FOR A NEW 19 STORY MIXED USE HOTEL & APARTMENT FACILITY REVISION #1 TO ADD FOLLOWING ITEMS TO THE SCOPE OF WORK. FIRE ALARM AND SMOKE CONTROL WIRING, VOICE/DATA LOW VOLTAGE WIRING, 2-WAY COMMUNICATION WIRING, DISTRIBUTED ANTENNA SYSTEM WIRING, WIFI ANTENNAS AND WIRING, EMERGENCY GENERATOR WIRING, APARTMENT MAIN DOOR ENTRANCE SYSTEM, SECURITY WIRING. REVISION #2: ADD STREET LIGHTING TO THE SCOPE OF WORK. Valuation of single family: $0.00 Fees Collected: $57,648.05 Valuation of mf/comm: $7,617,032.00 Type of Work: NEW Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2017 International Residential Code Edition: 2015 WA Cities Electrical Code: 2017 International Mechanical Code Edition: 2015 WAC 296-4613: 2017 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature:� );, /� \ ` Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the p .rformance of work. I am authorized to sign and obtain this development permit n a ee to the cond do a) hed to this permit. l Signature: Date: (� l Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7002 SERVICE 7002 SERVICE 7002 SERVICE 7002 SERVICE 7002 SERVICE 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 0223100090 Permit Number: EL15-0899 Address: 223 ANDOVER PARK E Issue Date: 12/10/2015 Permit Expires On: 10/3/2017 Project Name: WASHINGTON PLACE - BUILDING Owner: Name: WASHINGTON TOWERS LP Address: 18230 E VALLEY HIGHWAY #195 , KENT, WA, 98032 Contact Person: Name: LEN WHALEN Address: 6412 S 196 ST, KENT, WA, 98032 Contractor: Name: E C COMPANY Address: PO BOX 10286, PORTLAND, OR, 97296 License No: ECCOM**148BA Lender: Name: Address: , , , Phone: (206) 436-6048 Phone: (503) 224-3511 Expiration Date: 6/30/2018 DESCRIPTION OF WORK: ELECTRICAL POWER AND LIGHTING FOR A NEW 19 STORY MIXED USE HOTEL & APARTMENT FACILITY REVISION #1 TO ADD FOLLOWING ITEMS TO THE SCOPE OF WORK. FIRE ALARM AND SMOKE CONTROL WIRING, VOICE/DATA LOW VOLTAGE WIRING, 2-WAY COMMUNICATION WIRING, DISTRIBUTED ANTENNA SYSTEM WIRING, WIFI ANTENNAS AND WIRING, EMERGENCY GENERATOR WIRING, APARTMENT MAIN DOOR ENTRANCE SYSTEM, SECURITY WIRING. Valuation of single family: $0.00 Fees Collected: $55,998.62 Valuation of mf/comm: $7,527,032.00 Type of Work: NEW Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: W,Z, VY � Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: ; oni(A� Date: Print Name: Z IJ ,. W1-1-W /-,- A/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB City of Tukwila * Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov ELECTRICAL PERMIT Parcel No: 0223100090 Permit Number: EL15-0899 Address: 223 ANDOVER PARK E Issue Date: 12/10/2015 Permit Expires On: 6/7/2016 Project Name: WASHINGTON PLACE - BUILDING, Owner: Name: WASHINGTON TOWERS LP Address: 18230 E VALLEY HIGHWAY #195 , KENT, WA, 98032 Contact Person: Name: LEN WHALEN Phone: (206) 436-6048 Address: 6412 S 196 ST , KENT, WA, 98032 Contractor: Name: E C COMPANY Phone: (503) 224-3511 Address: PO BOX 10286, PORTLAND, OR, 97296 License No: ECCOM**148BA Expiration Date: 6/30/2016 Lender: Name: Address: DESCRIPTION OF WORK: ELECTRICAL POWER AND LIGHTING FOR A NEW 19 STORY MIXED USE HOTEL & APARTMENT FACILITY Valuation of single family: $0.00 Fees Collected: $55,998.62 Valuation of mf/comm: $7,527,032.00 Type of Work: NEW Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: W�/ W Date: h 1 o I ✓ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit •dagr a to the condi ons a tached to this permit. l Signature: Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 11t1p://www.Tukwi1aWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: LA m I (� (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mai! ^r by fax. "Please Print" SITE LOCATION A King Co Assessor's Tax No.: 0 2,23 100 90 Site Address: 223 R ijDOV ER PK . 0' Suite Number: Floor: Tenant Name: W AAN I Ni fOIJ I SAAC6 New Tenant: ❑ .....Yes ❑ . No PROPERTY OWNER Name: N N V A; PLA Address: 41A" IN 2 0 C.K City: `' OA17- State: , . /A Z>p On CONTACT PERSON— person receiving all project communication Name: 40f) OALElls Address: City: ew-r State: WA zip:1A... Phone: %o's 1 `60 Email. ,epA IJ 0 96.4 - eo oof Valuation of Project (contractor's bid price): ELECTRICAL CONTRACTOR INFORMATION Company Name: C Address: City: Al . State: Zip ���Z Phone: ad" ,4346. eVIWlsi�•G•co.co Contr Reg No. C �o M mop m Exp Date: Tukwila Business License No.; 145 M Scope of Work (please provide detailed information): & A —a aJ—n4<A& NDAUffl F L. A f$ FfT/Ny F'01% Will service be altered? © Yes Type of Use: ❑ No N AC Adding more than 50 amps? ❑ Yes ❑ No Tyne of work: Ig New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: %] Puget Sound Energy ❑ Seattle City Light HAApplications\Forns-Applications On Line12014 ApplicationsElectrical Permit Application Revised 1-I-14.doc Revised: January 2014 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings...................................$152.85 (including an attached garage) « ❑ Garages, pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat).................................$59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration.......................................$81.90 (no added/altered circuits) ❑ Service change with added/altered circuits.................$81.90 number of added circuits .......................$11.55 ea ❑ Circuits added/altered without service change ............ $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ............ $54.60 (6 or more circuits)...............................................$7.65 ea ❑ Meter/mast repair........................................................$68.25 ❑ Low voltage systems.................................................$59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) .................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ................ $10.80 ea 'EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: el Date: 1© Print Name: L�� !I dam- U1 I" Day Telephone: 9-496 Mailing Address: iv `fl2 �b_ %�i�o SYI� ? / �%V' a1.4 g6DY-2 City State Zip H:\Applicatiom\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: July 2013 bh Page 2 of 2 • DESCRIPTIONS PermitTRAK PAID $1,649.43 EL15-0899 Address: 223 ANDOVER PARK E Apn: 0223100090 $1,649.43 Credit Card Fee $48.04 Credit Card Fee R000.369.908.00.00 0.00 $48.04 ELECTRICAL $1,525.13 PERMIT FEE MULTI-FAM/COMM 11000.322.101.00.00 0.00 $1,525.13 TECHNOLOGY FEE $76.26 TECHNOLOGY FEE RECEIPT:TOTAL FEES PAID BY R000.322.900.04.00 0.00 $76.26 $1,649.43 Date Paid: Friday, February 16, 2018 Paid By: CHRISTINE LEE Pay Method: CREDIT CARD 52760G Printed: Friday, February 16, 2018 8:32 AM 1 of 1 SYSTEMS DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $45,229.65 EL15-0899 Address: 223 ANDOVER PARK E Apn: 0223100090 $45,229.65 ELECTRICAL $43,075.86 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $43,075.86 TECHNOLOGY FEE $2,153.79 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT:R6832 R000.322.900.04.00 0.00 $2,153.79 $45,229.65 Date Paid: Thursday, December 10, 2015 Paid By: CHRISTINE LEE Pay Method: CREDIT CARD 02596D Printed: Thursday, December 10, 2015 9:59 AM 1 of 1 17TIff SY57EM5 Date Paid: Thursday, October 15, 2015 Paid By: CHRISTINE LEE Pay Method: CREDIT CARD 07372D Printed: Thursday, October 15, 2015 10:53 AM 1 of 1 �"fSYSTEMS INSPECTION RECORD] Retain a copy with permit l.vl r INSPECTION NO, PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3 77V Permit Inspection Request Line (206) 438-9350 Project: , Type of Inspection: A- � Address: n� Date Called: Special Instructions: Date Wanted: A- Requester:a.m Phone No: D U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS Et ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 F. Project: a LZ � Type of Inspection: Address: 06 Date Called: Special Instructions: Date Wanted: a. p.m. Requester: Phone No: / �V Approved per applicable codes. 1-1Correctionsrequired prior to approval. U paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit �( l INSPECTION NO. PERMIT 1- CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431- Permit Inspection Request Line (206) 438-9350 Project: d Type of Inspection: Address: Date Called: Special Instru ions: Date Wanted: / ajw p .m. rRequester: Phone No: ElApproved per applicable codes. 1 Corrections required prior to approval. IInspector: \ IIH M /dam IDate: 05I17 I ty I El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD CRetain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: M. C p.m. i Requester: r ne No: Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit I d4(4 INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: bc� Address: Date Called: Special Instructions: Date Wanted: a.m. 1(L Requester: Phone No: z G/ - Approved per applicable codes. 11 Corrections required prior to approval. i i paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (� INSPECTION RECORD !� l Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 0 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: a. p.m. Requester: Phone No: nApproved per applicable codes. LJ Corrections required prior to approval. spector: C ❑ REINSPECTION rEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Sou hcenter Blvd.. Suite 100. Call to schedule reinspection. p� INSPECTION RECORD ( Retain a copy with permit INSPI ION N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., 4100, Tukwila. WA 98188 (206) 431- Permit Ins Fection Request Line (206) 438-9350 Project: ( Jh Type of Inspection: Address: � �� Date Called: r Special Instru tions: Date Wanted: CLm eA p.m. Requester: Phone No: 7-p� Approved per applicable codes. F-1 Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Catt to schedute reinspection. /4 M INSPECTION RECORD Retain a copy with permit �S - �� 9 INSPECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd_, #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Tyne -of Ins ection: Add%R ss: do Date Called: Special Instructions: ' Date Wanted: a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: p"1 1 e( t- Vvt e, r Pi a n 4 6 Act-c.e. i Lf c, 0 f REMPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Catt to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 .4 Project: I . FL Type of Inspection: Address: Date Called: Special Instru ions: �h �( Date Wanted: Z 2-- p'.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. u paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit116u��o INSPECTION NO. PERMIT 40. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: C'06 Address: / Date Called: Special Instru tions: Date Wanted: a.m p.m. i7Requester: r+/� 1 bb , � rh�eNo: �Q, o, C . Approved per applicable codes. LJ Corrections required prior to approval. paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD l� Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431- Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: y� / Address: Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: ❑ Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPEC ION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspgction Request Line (206) 438-9350 ss: Approved per applicable codes. Date Called: Date Wanted: a.m .m Requester: Phone No: 0& KO 214t Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit IV ✓m INSPECTION NO. PERMIT 1110. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 _ s: Co LAAt4 5 ryL nspection: ;06 .m. Approved per applicable codes. E Corrections required prior to approval. REINSPECTIgN FEE REQUIRED. Prior to next inspection*, fee must be paid at 6300 gouthcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 107 Retain a copy with permit I PEC ION NO. PERMIT NU. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 43 -3 Permit Inspection Request Line (206) 438-9350 f Project: LAA. ,, .. L C� Ty of I spec i n: f Address: Z-0 Ap , Date Called: Special Instructions: Date Wanted: a. p.m. Requester. Phone No: u Approved per applicable codes. LJ Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. m INSPECTION RECORD. /A U Retain a copy with permt (eV INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: R"ka Type of Inspection: M Address: � Date Called: Special Instructions: � rt Date Wanted: a.m aia p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. / INSPECTION RECORD 1 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 0 Permit Inspection Request Line (206) 438-9350 Project: UA Type of Inspection: Address: Z � Date Called: Special Instructions: Date Wanted: 7- p. Requester: Phone No: Z®G 24V ❑ Approved per applicable codes. LJ Corrections required prior to approval. paid at 6300 Southcenter Blvd., Suite 100. Gall to schedule reinspection. / INSPECTION RECORD&1-01-lV Retain a copy with permit)--0 INSPECTI N NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Insp ction Request Line (206) 438-9350 Project: Type of Inspection: Address: Y l• Date Called: Special Instru ons: Date Wanted: 7 !/ P Requester: Phone No: Approved per applicable codes. 1-1 Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Catl to schedule reinspection. INSPECTION RECORD 61��-Oy IV3 1 Retain a copy with permit INNPECTION NO. P MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-36 Permit Insption Request Line (206)�$j9350' 11 . Project: UJA- - Pc-,ircllt� '4 c to Address: L2—i /otr-" Date Called: Special Instr tions: Date Wanted: .m. P• Requester: Phone No: Approved per applicable codes. 1-1 Corrections required prior to approval. U paid at 6300 Southcenter Btvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION l 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 IProject: OA- _ (� ITYpe of In k Ih n. / rWAl.., ress:;, ons: ❑ Approved per applicable codes. LJ Corrections required prior to approval. '—' paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 101 Retain a copy with permit�41��A`V* INSPECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 Project: /� /t1AJ- -P Type of Inspe ion: r�V Address: ��3 AT6 Datk Ca ed: I Special Instructions: Date Wanted: a.m .m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: t r f L-Ii C-6) b." Ji JAI i-1-5 Z t( {Inspector: J4( IDate: o;llfq h REINSPECTION F15E REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. /00 INSPECTION RECORI'W' I 5�6 Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431- Permit Inspection Request Line (206) 438-9350 Project: , Type of Inspection: Address: Date Called: Special Instructi ns: Date Wanted: 2 f a.m. .m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. ,/ I 'if (-'�I SJIIF" ) - II nspector: 0 REINSPECTIONIFEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD( Retain a copy with permit �y INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: WA w���,�Type of Inspection: 4� L Address: „ ^ 7 J f Date Called: Special Instructfons: uate wantea: i a. p.m. Requester: r Phone No: 00 KO 7,1L� Approved per applicable codes. M Corrections required prior to approval. COMMENTS: I paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. INSPECTION RECORD Retain a copy with permit l INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: Ty f Inspection, QVf14 /�V Address: � Date Called: Special Instruc ions: Date Wanted: a.m. p.m. Requester: 4/i p t/ � 7,� �i� L'( Phone No: ! 2-ob ElApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: i Ise"S IF ns pector: Date: 0 REINSPECTIONIFEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I r INSPECTION RECORD �. Retain a copy with permit )��, INSPECTION NO. PERMIT NO.' CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 1 Project: Lk rr VType W of Inspection:64A Address: '� ,- Z ----5 Alt - Date Called: Special Instructions: ( Date Wanted: a. , 7, c :Pl _2 Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. INSPECTION RECORD .l Retain a copy with permit ' INSPECTION NO. PERMIT I. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3` Permit Inspection Request Line (206) 438-9350 Project:o, ,��``� � 1,-k!L Type of Inspection:/k 1 j—, Address: �v Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: nApproved per applicable codes. L, Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD ,/ G Retain a copy with permit INSP CTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: I¢¢ k Type of Inspection: Aj Address: Date Called: Special Instructions: Date Wanted: ` f a. \ P.m. Requester: Phone No: 11 Approved per applicable codes. 11 Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD �. Retain a copy with permit INSPECIPION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367I Permit Inspection Request Line (206) 438-9350A Project: � ,// jai Type of sae tion: j A- ., (� LG V I'A Address: � � Date Called: Special Instructions: _( Date Wanted: a. Requester: Phone No: 1,0 6 nApproved per applicable codes. l:J Corrections required prior to approval. COMMENTS: d i ool -- Ak(-5-'6(-. i� PliesNi—iKoorl- nspector: REINSPECTIdN FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: j Pi Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: , b a.m. d Requester: Phone No: (7��� Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 4 waft Ilnspector: I—/ tri n (/�c � IDate: 01 REINSPECTION IFEE REQUIRED. Prior to next inspection, fee'must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. J INSPECTION RECORD I � Retain a copy with permit INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36V., Permit Inspection Request Line (206) 438-9350 Project: �. A - !` ✓ , `{ Type of Inspection: F-4-4t,' Address: te o'I Date Called: or Special Instructions: Date Wanted: a.m. Requester: Phone No: r Z r Approved per applicable codes. Corrections required prior to approval. COMMENTS: 23 16- 10# dam. Date: REINSPECTION rEE REQUIRED. Prior to next inspectidn. fee Fnust be paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspiection Request Line (206) 438-9350 Project: A Inspectio PDat?ed: �Vo' Address: r Cq Special Instructions: Date Wanted: a.m. Requester: Phone No: ElApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 1. Pr JZ3 U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: Uj ✓ ��/ Type of Inspection: e ' Address: �-Z— Date Called: Special Instructions: Date Wanted: ` a Requester: Phone No: 11 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: jil �rt b f� . L� r{ PL � s REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 0 J INSPECTION No. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-uouv Project: 0A I Type of Inspection: ` Address: Z?--3 hp, / C Date Called: Special Instructions: a. Date Wanted: / /7 m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 0 Retain a copy with permit INSPECTION NO. PERMIT 1- CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspeftion Request Line (206) 438-9350 P, Project: Type of Inspection: Address: e7 Date Called: Special Instructions: Date Wanted: a. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 12 )l-, Inspector: Date: ®` 1 REINSPECTION FEE REQUIRED. Prior to next inspection, feelmust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permitfi4,(D INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 Project: r � � Ty f If pection: Address: L Date Called: Special Instructions: j.4 Date Wanted: a. Of p.m. r Requester: Phone No:� nnr !,0 f,> Approved per applicable codes. LJ Corrections required prior to approval. I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Q INSPECTION RECORD l� Retain a copy with permit INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: T e of inspection: �^At I L l Address: � Date Called: Special Instructions: 3tO � 7 q_� Date Wanted: a.m h M. Requester. Phone No: EJApproved per applicable codes. LJ Corrections required prior to approval. • r� 9 r • i � r �? U paid at 6300 Southcenter Blvd., Suite 100. Call, to schedule reinspection. INSPECTION RECORD Retain a copy with permit �Y INSPE ION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 . Project:V Type of Inspection 1 Address: 11-2 3 AW Date Called: Special Instructi ns: Date Wanted: a.m Ly p.m. Requester: Phone No: ,• , `s-n Approved per applicable codes. E Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. INSPECTION RECORD l Retain a copy with permit d l INSPECTION N0, PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: / U4- Type of Inspection:- // DJ t? I,,/- Address: /,1: Date Called: Special Instruc ions: Date Wanted: IL03 a.m. Requester: Phone No: z `* Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. �7 INSPECTION RECORD Retain a copy with permit INS CTION N0. PERMIT 1.0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 0 Project: VJ ( Type of Inspection:&" Address: Date Called: Special Instructions: Date Wanted: g a.m Requester: Phone No: -C �L,, pp l 0 Approved per applicable codes. E Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 Project: ` Type of Inspection: /// Address: Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: VA f,I ` D z�-7 REINSPECTION(FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 6�,�,OjjjjRetain a copy with permit INSPECTION N0, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: j Type of Inspection: &A,4- Address: Date Called: Special Instructions: Date Wanted: 140 �—�m Requester: Phone No: n^/ 11 Approved per applicable codes. LJ Corrections required prior to approval. I I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ?,� INSPECTION RECORD' 0 Retain a copy with permit `� INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit InspFction Request Line (206) 438-9350 Project: AA k/ Type of Inspection: Address: f�3 � Date Called: Special Instructions: Date Wanted: a.m. 11,7 / .m. Requester: Phone No: r� _ 6 ❑ Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 01 INSPECTION RECORD L21�:flq Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 0 Permit Inspection Request Line (206) 438-9350 Project: bjk - P"i-c-6 Type of Inspection: Address: "1 Date Called: Special Instructions: Date Wanted: a. (k p.m. Requester: Phone No: ❑ Approved per applicable codes. LJ Corrections required prior to approval. U - , paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD lRetain a copy with permit1 73 l INSPECTION NO. PERMIT N0. " CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: Type o I6-pe ion: Address: Date Called: Special Instructions: Date Wanted: M. 11/17 P. Requester: V Ica Phone No: ElApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 7 00 A- r u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ��INSPECTION RECORD. ��� l Retain a copy with permt INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit InspeVon Request Line (206) 438-9350 Project: WA-. �� Type of Inspection: 6 f �� Address: Date Called: Special Instructions: Date Wanted: a. p.m. r � LA �j, ( � Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. nspector: Date: 0 REINSPECTIOt FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 15'� INSPECTION NO. PERMIT N,. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 0 Permit Inspection Request Line (206) 438-9350 A Project: TypA4--- n: Address: � 0 Dat Special Instructions: Date Wanted: a.m. 11107 0 p.m. Requester: Phone No: 2- Q/0 Approved per applicable codes. 1-1 Corrections required prior to approval. COMMENTS: 14!.1s a % ,� �6�t c- ,/,� 1`ip0 /�,1,— . s 1 �wb / T! , IInspector: - /1ri { r`- 1Uate: 1 1 I0% /0 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD / Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 f f A w Project: A hT Type of ntppect n: ` f t! Address: Date Called Special Instructions: Date Wanted: C� a.m M. Requester: Phone No: ❑ Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: r U� �+�►wm LJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 04 V4 rn�I INSPECTION RECORD _7V Retain a copy with permit ^� INSPtClION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: WA- Lkc,,6 Type of Inspection: Xt[44* Address: Z2-3 Date Called: Special Instructions: Date Wanted: a.m lc:)2 .m. Requester: Phone No: 11 Approved per applicable codes. 1_J Corrections required prior to approval. COMMENTS: i v M. .� �- L(� (..JqV1 zV c, O _ l;� Inspector: REINSPECT16N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �J INSPECTION RECORD �(� Qqq / 3 Retain a copy with permit i � o� d 1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 0 Permit Inspection Request Line (206) 438-9350 Project: " - Type of Inspection J� I Address: �067A) Date Called: Special Instructions: _( Date Wanted: a.m 1,07%' p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1 INSPECTION RECORD � I 7z Retain a copy with permit lii INS ECTION No. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: y To u-45 1=8 y nspector: Date: REINSPECTIO14 FEE REQUIRED. Prior to next inspection. tee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. y INSPECTION RECORD " / �1 Retain a copy with permit �'l5 —0 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: � Type of Inspection: Address: Z2- / Date Called: Special Instructions: Date Wanted: AA o a.m /0 6 P.M. Requester: Phone No: Approved per applicable codes. 1_J Corrections required prior to approval. COMMENTS: L-1` l 1 / vikkl ®. 60 �- 1,-2- --1A 0 ❑ REINSPECTION PEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD ,��q Retain a copy with permit I INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: (Aj&. Type of Inspection: tA/ Address: Date Called: Special Instructions: Date Wanted: I Requester: Phone No: EJApproved per applicable codes. EI Corrections required prior to approval. COMMENTS: 7771 ZA— LIt o04 1-( r40 t WW Ato?KAO t r- POOL-myp i-tm '--- ' paid at 6300 Southcenter Blvd., Suite 100. Gall to schedule reinspection. INSPECTION RECORD l� Retain a copy with permit INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: WA, Type of Inspection 4044 /J Address: Date Called: Special Instructions: Date Wanted: a.m. L 10 Requester: Phone No: Approved per applicable codes. F-1 Corrections required prior to approval. COMMENTS: y r `0j V CTIV 0 --( u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD / q Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request line (206) 438-9350 Project: (IJ Type of Inspection: Address: 77 Date Called: Special Instructions: ) 3 /L� 'A fI L,5 , P L I/" CJ � Date Wanted: a.m p.m. Requester: Phone No: Zak y�� 2JJ Approved per applicable codes. LJ Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. / INSPECTION RECORD V7 Retain a copy with permit INSPECTION NO. PERMIT I — CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: s Type of Inspection: Address: i a Date Called: Special Instructions: Date Wanted: a. p.m. V g c.�l, �VIJj Requester: Phone No: / is �' �� I Approved per applicable codes. LJ Corrections required prior to approval. tJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit �'��'a � INSPECTION NO. PERMIT NO. CITY OE TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: A /V . � Type of Inspection: . // aVG t4 /N Address: 2-7-3 06 Date Called: Special Instruc 'ons: L� Y�� �' �� Date Wanted: y a. I p.m. Requester: Phone No: M ❑ Approved per applicable codes. LJ Corrections required prior to approval. paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 0 Permit Inspection Request Line (206) 438-9350 Project: A� - e c ' n: T 99 M 1cb to 04 14 W Address: i Z2,3 O Date Called: Special Instructions: G I LA D5 A,v P f� %C J ) Tyso Date Wanted: a.m p.m. Requester: Phone No: Z Approved per applicable codes. L]Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 1(, ��p�1Q tU Retain a copy with permit,' INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: /4 .f T f nsp do 4 Address: Date Called: Special Instructions: Date Wanted: .m. Requester: Phone No: ❑ Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 1 6"ice t4I L 3 32 374 ri -C 5 D I sue, � -- LL REINSPECTIFEE REQUIRED. Prior to next inspection, fee must be paid at 6300 5outhcenter Blvd., Suite 100. Call to schedule reinspection. 5� INSPECTION RECORD I /�-o / Detain a copy with permit INSP TION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 0 Permit Inspection Request Line (206) 438-9350 11 Project: [X/4- P Type of Inspection: Address: Date Called: Special Instruc ions: 3 C q I&TC-0 Date Wanted: aAn n. Requester: Phone No: 210( ,l-O 21y / 11 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: ,r FORE I - (Inspector: �Jl jldWA16k (Date: 6 F J3© ft7 1 REINSPECTION'FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 62' Retain a copy with permit ml�D INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: LA_ Type of Inspection: 0tj Address: kp(— Date Called: Special Instr tions: Date Wanted: a.m 7j P.M. Requester: Phone No: !� l Q l �. Approved per applicable codes. E Corrections required prior to approval. COMMENTS: I I- t I- W -A'GwS 440 1-WU0L IL)S I 4- 4 G / Ilnspetto L INT) �, / f� It7ate• Dip/' ? l t% I REINSPECTI'ON FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD�- �p Retain a copy with permit 64 Z INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 SoUthcenter Blvd.., #100, Tukwila. WA 98188 (206) 431.3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: � A-P67 Date Called: Special Instructions: Date Wanted: a.m Requester: Phone No: o In Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Catt to schedule reinspection. 6 � INSPECTION RECORD Retain a copy with permit '0 INSP CTION NO. PE MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd— #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection, Address: Date Called: e Special Instructions: Date Wanted: IY7P.M. A Requester: 7-- Phone No: Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit (, I INSPECTI N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � V� Type of Inspection: Address: / i Date Called: Special Instructions: v� � aA t— � Date Wanted: a.m p.m. Requester: Phone No: 11 Approved per applicable codes. LJ Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD1 37 ��Qq Retain a copy with permit `(( INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: /jam. �/`� •"� - Lr19 �7S Zp;t 01� Address: Date Called: Special Instructions: 1/� �`�'/ � D 5 R It l0 PAJ" Date Wanted: a.m. Requester: Phone No: b � 11 Approved per applicable codes. ElCorrections required prior to approval. Date: 0c REINSPECTIdN FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD �7 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: A'- C/C Type of Inspect{ s r Address: �� � Date Called: Special Instructions: Z_''g Date Wanted: a. Requester: Phone No: y b zv 1-1 Approved per applicable codes. El Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: Address: �Z 4- �I Date Called: Special Instructions: Date Wanted:. P.M. Requester: Phone No: Approved per applicable codes. 11 Corrections required prior to approval. " paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NA. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspgction Request Line (206) 438-9350 n 101 Project: i VA I Type of Inspectio Address: 72 z 9C Date Called: Special Instructions: Date Wanted: a.m ©I, Requester: Phone No: Approved per applicable codes. l_J Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit (L4(,0 INSPECTION NO. PERMIT 1- CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: k i (li . P� Type of Inspection: Address: N �- '0W Date Called: Special Instructions: Date Wanted: a. Requester: P. - 611 Phone No: Lffo � I ❑ Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: ® Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: a. -7 C P•m• Requester: IF Phone No: Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 32- Retain a copy with permi"NO. INSPECTION NO. CITY OF TUKWILA BUILDING D 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: J., "L Type of Inspectio �cOCj,f7 1. Address: j� Date Called: Special Instructions: Date Wanted: a.m. L- 3 4 J �A-v" 7111 Requester: Phone No: Z b 2 Approved per applicable codes. LI Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, tee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �j INSPECTION RECORD I i 1 Retain a copy with permit &" INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Insp ction Request Line (206) 438-9350 Project: Q K a Type of Inspection: Address: � Date Called: Special Instructions: Date Wanted: v a.m p.m. Requester: Phone No: �'VIr "(/ I— (,IV Approved per applicable codes. Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 10 ,�i� INSPECTION RECORD Q l 5J v ]Retain a copy with permit1 An INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: I PM (,t,JA- . L,A-c,6 Type of Inspection: Id Address: W Date Called: Special Instructions: CE IAA ( NJ61,I)( Date Wanted: a.m. .m. Requester: Phone No: `y )4q l Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspelction Request Line (206) 438-9350 Project: � Type of Inspection: q 0— Address: C Date Called: Special Instructions: fwRequester. ( Date Wanted: p.m. Phone No: Approved per applicable codes. LJ Corrections required prior to approval. '—' paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD 4Q� 70 Retain a copy with permit 164 �(J INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., if100, Tukwila. WA mioo (206) 4.51-3670 Permit Inspection Request Line (206) 438-9350 Project: (A/ik- Type of Inspection: ffQ,)4t4- 1A Address: 17 Z- 3 Ape Date Called: Special Instructions: Date Wanted: a.m. .m. AJA_j Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. INSPECTION RECORD Ig `?;:oQ Retain a copy with permit '1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ress: �A4M hM l,4 L/ I Approved per applicable codes. LJ Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �'7 INSPECTION RECORD 16,4 �O/lRetain a copy with permit JT INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: WA,KI)04 Type of Inspection: I'l Address: 2Z3 Date Called: Special Instructions: Date Wanted: / a. tCjMy p.m. CCtI,I�G, LII Requester: Phone No: 5z I Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS:' OA e N1,11 IN NW �. L-1 O D L 2 145rl o R..r �. 2�10 �' A nspector: REINSPECTIO14 FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD/ q Retain a copy with permit V'U - INSPECTION NO. PERMIT 1- CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ok ^ �/ Type of Inspection:4VL4 / A/_ Address: A3 AP6 Date Called: Special Instructions: Date Wanted: ®� a. p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 16, Retain a copy with permit��" l INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: �-.kb'J4t F. �� Type of Inspection: Address: 123 E Date Called: Special Instructions: Date Wanted: i J45 / Requester: Phone No: ElApproved per applicable codes. 11 Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. qIy I INSPECTION RECORD � I Retain a copy with permit L`�' 'D�� INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 0 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: _ I Address: 2-2-3 AP(Date Called: Special Instructions: Date Wanted: a. p.m. Requester: Phone No: v Approved per applicable codes. E Corrections required prior to approval. COMMENTS: Irk A-" Ll 1 4C& r �lnspecto ��/' � (Date: o f3,,-- h7 REINSPECTI¢N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. A INSPECTION RECORD 1-1-1Retain a copy with permit1 AA INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: �. Type of Inspection: �( 0 l Address:�� , Date Called: Special Instructions: Afi' Date Wanted: a.m. p.m. Requester: Phone No: 11 Approved per applicable codes. LJ Corrections required prior to approval. • �lnspector: /,� IDate: �,�J��'�•7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �lnspector: /,� IDate: �,�J��'�•7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: fE , Type of inspection:. Address: 2 , Date Called: Special Instructions: Date Wanted: P- a. 5 �. q p.m. Requester: Phone No: If % Approved per applicable codes. LJ Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Infection Request Line (206) 438-9350 Project: a PL* Type of Inspection: ,,f1 �v 4 4- Address: .. Date Called: Special Instructions: LJ ®< Date Wanted: a.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. " paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD q Retain a copy with permit ! INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: �0 nT Address: Date Called: Special Instructions: Date Wanted: p.m. Requester: Phone No: ❑ Approved per applicable codes. EJ Corrections required prior to approval. " paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD1 37 �� Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspectiork 1 ` 0 0 :6 Address:p/ cj Date Called: Special Instructions: 1 2' _ r to Lfi Date Wanted: a.m. Requester: Phone No: � j o ) r I ElApproved per applicable codes. E Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. �� INSPECTION RECORD 04. NNO. Retain a copy with permit INSPECTION NO. PE CITY OF TUKWILA BUILDING DIVIS 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ( Permit Inspection Request Line (206) 438-9350 Project: yJ Type of Inspection: wo Z4 Pi Address: Z Date Called: Special instructions: Date Wanted: m. p.m. Requester: Phone No: Approved per applicable codes. 1 Corrections required prior to approval. IInspector: /®,1A dK IDate: 0 VI4 / P 7 REINSPECT101 FEE REQUIRED. Prior to next inspection, fee itnust be paid at 6300 Southcenter Blvd.. Suite 100. Cali to schedule reinspection. 37 1INSPECTION RECORD Retain a copy with permit �e kll / V INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �- Type of Inspection: oU, L ©1 +� 1AJ_ Address: Date Called: Special Instructions: Date Wanted: a. p.m. Requester: Phone No: /`�� vi Approved per applicable codes. 1:1 Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD � t� Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 u Project: W VLA-CleType of Inspection: 6vw4 Address: �? ABE Date Called: Special Instructions: L A J. f� 1p 1 I 1 Date Wanted: Requester: Phone No: u(-0 ❑ Approved per applicable codes. LJ Corrections required prior to approval.. `—' paid at 6300 Southcenter Blvd., Suite 100. Gall to schedule remspection. INSPECTION RECORD Retain a copy with permit'" INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: j Address: � � Date Called: Special Instructions: Date Wanted: (� a.m. Requester: Phone No: U �l Approved per applicable codes. LJ Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPEC ION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 w / Project: Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: a.m .m. 44, Requester: Phone No: 11M-0 � P ElApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: r � Ary- ! 40 L �T" Q-thI3 AW -b Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee m6st be paid at 630q Southcenter Blvd.. Suite 100. Call to schedule reinspection. !INSPECTION RECORD�3 Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: a.m. M. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 9 INSPECTION RECORD 33 Retain a copy with permit INSPECTION NO. PERMIT NU. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: A- Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: p.m. Requester: Phone No: w 2A 1 ❑ Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 32— 1 INSPECTION RECORD �. Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: (AJA-, KkC.,6 Type of Inspection: Address: 2 3 Date Called: Special Instructions: Date Wanted: / a.m. p.m. Requester: Phone No: yTo 4-r y Approved per applicable codes. E Corrections required prior to approval. (Inspector: —//11A A Iuate: 0-3// to h 7 REINSPECTIdN FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Gall to schedule reinspection. 3I INSPECTION RECORD Retain a copy with permit1616�01907 INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: A S. Type of Inspection: &O)L 4 Address: Date Called: Special Instructions: Date Wanted: a.m M. Requester: Phone No: ❑ Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 61L - I INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ! J & 11 &d, Type of Inspection. 00 Address:OF Date Called: Special Instructions: Date Wanted: a.m. 0 Requester: Phone No: 11 Approved per applicable codes. a Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. e7qINSPECTION RECORD q Retain a copy with permit �� I INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 630O Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Insp ction Request Line (206) 438-9350 Project: _ Type of Inspectio Address: i Date Called: Special Instructions: Date Wanted: a,m u m. Requester: -� Phone No: Approved per applicable codes. 1:1 Corrections required prior to approval. I I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD q 2, Retain a copy with permit '� 1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspectio . ��/, e / Address: �( Date Called: Special Instructions: Date Wanted: a.m C Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: t t r LJL !` A -PJP paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 2-7 Retain a copy with permit a4 10 INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 6645 Type of Inspection: % Address: AP Date Called: Special Instructions: Date Wanted: h a. Requester: JPhone No: �_O 2.4 u Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: fA 6 • 'w. Vim/ 3 ' I lJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ' INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: LAA - V��— Type of Inspections Address: 7,7 ao- Date Called: Special Instructions: Date Wanted: t� Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. REINSPECT101 FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 So. thcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD 144 � QRetain a copy with permit > ��I INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspeltion Request Line (206) 438-9350 Project; Type of Inspection: R. tot);t4 14 Address: �� Date Called: Special Instruct ons: Date Wanted: a. Requester: Phone No: ffo q Approved per applicable codes. LJ Corrections required prior to approval. i . V1 I IInspector: < ///11) NdK Iuate: ®t /-s--N EJ REINSPECTIO� FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 7-q Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: 04 Address: Date Called: Special Instructions: Date Wanted: a. Requester: Phone No: ❑ Approved per applicable codes. F-J Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD + Retain a copy with permit�� INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �� eIn pectin Address: ,. Date Called: Special Instructions: Date Wanted: a topp.m Requester: :&m— rone No: ❑ Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: ^l r - c-ot V• -eTt c. Cs�W'Nvir S 691-*Ceeq 564- . of l'0l I ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD ov�oj11 ff Retain a copy with permit G INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 n Project: WA- Type of Inspectionn- Address: � 7 i Date Called: Special Instructions: Date Wanted: a. Q) p.m. Requester: i r Phone No: �Z Z ' Approved per applicable codes. 1 Corrections required prior to approval. U paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: cV Type of Inspection:�� g -� Address: 2Z� Date Called: 1p Special Instructions: Date Wanted: a.m. 7 Ll- p.m. Requester: Phone No: Approved per applicable codes. U Corrections required prior to approval. COMMENTS: V s.LMDK&UNP eD , t{ 5 U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD �j 20 Retain a copy with permittv(-03711 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: J101, , Type of Inspection: Address: )7 Date Called: Special Instructions: Date Wanted: 71[2, a.m. �Z Requester: Phone No: �00 / /� G Approved per applicable codes. 11 Corrections required prior to approval. Mrs .V 0• -6 rolmil j L WA IT i nspector: REINSPECTION IEEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD(,I 0 7 Retain a copy with permit 5 — INSPECTI N N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 w Project: F LV PLV-e Type of Insp�ctjgn Address: Date Called: Special Instructions: Date Wanted: P• Requester: Phone No: �l 33 l/ ❑ Approved per applicable codes. a Corrections required prior to approval. COMMENTS: r 6)AJDVIT-S /Y V I rT Inspector: c (� N� Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD f f Retain a copy with permit 0 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: � Address: ZZ Date Called: Special Instructions: Date Wanted: a Requester: Phone No: ' Z( 33 Approved per applicable codes. 1:1 Corrections required prior to approval. I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 7 1 Retain a copy with permit INSPECTION NO. PERMIT NO. f' CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-367 Project: Ty e of Ip�pection. Address: Date Called: Special Instructions: Date Wanted: a L� V p.m. Requester: Phone No: ❑ Approved per applicable codes. ❑ Corrections required prior to approval. l___I paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. j INSPECTION RECORD' Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: VA-- Type of Inspecti n: V J� Address-� Date Called: C Special Instructions: Date Wanted: p.m Requester: Phone No: 3 3o® L- Approved per applicable codes. a Corrections required prior to approval. I .I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit /mil INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: k s Type of Inspection: Address: �- Date Called: Special Instructions: Date Wanted: m. p• Requester: Phone No: Approved per applicable codes. l__J Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ' INSPECTION RECORD 1 Retain a copy with permit �jl j� T INSPECTION N0. PERMIT N0. CITY OF T111CW11 A BUILDING DIVISION 4) 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � ::&�� Type of Inp�cti Vq e,"A� Address. Z Date Called: Special Instructions: a. Date Wanted: q31p.m. Requester: Phone No: 17 Approved per applicable codes. Corrections required prior to approval. COMMENTS: L Inspector: �� Date: n ? REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ` INSPECTION RECORD l Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., 4100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: „ /�� t - Oate Called: Special Instructions: Date Wanted: q a.m Requester: Phone No: � T �Q Approved per applicable codes. Corrections required prior to approval. U paid at 6300 Southcenter Blvd.. Suite 100. Cali to schedule reinspection. 12- INSPECTION RECORD l�'l Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request tine (206) 438-9350 Project: Type of 1nv� lion: Address: �j /�� Date Called:. Special Instructions: Date Wanted: % m. Requester: Phone No: ❑ Approved per applicable codes. E Corrections required prior to approval. COMMENTS: "mv s nspector ate: ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r INSPECTION RECORD 16�1-�o I Retain a copy with permit l INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: k s Type of Inspection: Address: Date Called: Special Instruc ions Date Wanted: p.m Requester: Phone No: —7 �00 Approved per applicable codes. E Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD q Retain a copy with permit t INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address. 22 Date Called: Special Instructions: Date Wanted: r a. Requester: ! Phone No: � qq t Jll 3-0oL_— ❑ Approved per applicable codes. Corrections required prior to approval. pector: Date: IA REINSPECTIONd FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 1�,, �� ® Retain a copy with permit INSPECTION N0, PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3 770 Permit Inspection Request Line (206) 438-9350 Project: , Type of Inspection: Address: AA Date Called: Special Instructions: Date Wanted: raxp. O� m. Requester: Phone No: t_._J Approved per applicable codes. El Corrections required prior to approval. II paid at 6300 Southcenter Blvd., Suite 100. Call to scheduie reinspection. (� INSPECTION RECORD r/ I Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: i Date Called: Special Instructions: Date Wanted: a.m p.m. 3fi7 Requester: Phone No: � � 3DoZ- 0 Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD c� Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project: Type of Insp c on: � Address: ''/�]✓ v - Date Called: Special lnstructi s: Date Wanted: ff a Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedute reinspection. INSPECTION RECORD j 7 Retain a copy with permits l _ 1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., 4100, Tukwila. WA 98188 (206) 431--3670 Permit Inspection Request tine (206) 438-9350 Project: r Type of i spection: . Address: Date Called: Special Instructions: Date Wanted: n u'� _ Requester: Phone No: -� n Approved per applicable codes. 1-1 Corrections required prior to approval. L paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD AT Retain a copy with.permit INSPECTION NO. PERMIT NO. CITY OE TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ii- '' �V A (,�LE Type of Inspection: Address: Zl?- 3 AI/ Date Called: Special Instructi6ns: Date Wanted: a.m. p- 1 ` 1 t Requester: _ Phone No: Re 3oc�z-,,� L._._J Approved per applicable codes. 1:1 Corrections required prior to approval. " paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION Retain a copy INSPECTION NO. CITY OF TUKWILA 6300 Southcenter Blvd., #100, Tukwila. RECORD with permit h�� �Oyn PERMIT NO. BUILDING DIVISION WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspe�c 'on' �,vc&on Address: Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: 3 L y 3-&oZ-- ❑ Approved per applicable codes. E, I Corrections required prior to approval. COMMENTS: QA b" dp Inspector: � /t f 464k, � Date: Oz'16 !(11 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a cowith ermit INSPECTION NO, �.y PERMIT h0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � kAT"� ype of Inspection:-NAddress: �J� 3 A& Date Called: Special Instructions: Date Wanted: a.m p.m. Requester: Phone No: L l Approved per applicable codes. Corrections required prior to approval. COMMENTS: ffp eItor: I /„ Date: 0 REINSPECTIO14 FEE REQUIRED. Prior to next inspection, fee'must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permitG INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd,, #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: t�tt - Pt Type of Inspection: Address: ,i 7 e Date Called: Special Instructions: Date Wanted: / a.m. p.m. Requester: Phone No:. 3d (� Z- EJApproved per applicable codes. l—J Corrections required prior to approval. lJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. J INSPECTION RECORD C ' -- copy p Retain a co with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project: G Type of Inspection: f- �, J Address: Date Called: Special Instructions: Date Wanted: a r p.m. Requester: Phone No: J� Z— Approved per applicable codes. E Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r INSPECTION RECORD I / � q ( Retain a copy with permit ��C� ©�l INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: P� Type of Ins a 'on: � 4 Address: nt� Date Called: Special Instructions: Date Wanted: 77 a r!/ � p.m Requester:. Phone No: ❑ Approved per applicable codes. L, Corrections required prior to approval. COMMENTS: . f Zoi ' e Ilnspector: C/fII �J/4 /k_ IDate: f 3o /1Si El REINSPECTIO14 FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 1 , 1 _0 to M n1I 1 N co co '(D In = U O Q W Zp U) O U m N O 00 W U Z U N O Q Q7 � I O U C O Q! (D E 0- co CD C O CL C o= U� z 2 015 U � O cq Q Q � (ll a? �- Q. U U J(A cn U) J J J J J U3 Q J J J J Q F- cl) U) c Lo M aD M(O� O Uj QQQ U oaaWw L1J ;�ooQU o Z (AUU>Q 1- w w w w o J J.J JJ J .J J J J J J Q (n 0)U)c/)(nU) W ItooWti W (m (1) O) co N M I Q WOW�� o I=- OLL W W W W W Q LLI WWWWQ O Z JJ.JJ> F- E 00 o m A> ate) �m -S 0- o� �v c m Qa m 5E>0n3 2) C w U 7 `n m m n0 N t an`m .E m m Q N co CL m EmN>o rna m m� m m - YyyE�aLao m C O N p m c m co a- Cc .c a'L —> m p m N n c3cLmyco cp N��Lno0 pYmF-o c�am m>,F- p:3aam>, in EY 3 o a) E-0 C 00.2 @—'p E d,6 W a) 9O o N f0 (C 0 N 7 U (C6 22 E(oo2+ -oom 7 m .. m U mm N E o w ^)w 7 LL w C E n g L >,ny N m E O N N w m H mtwo�a=NE co m o Q j i U> (6 co co MA m m a) W N m U L 0�-C p �Em O N a. (0 O. C O CDLL .T. (D m N O 0 y N U a)U LL- C N O m m m M m 7Da nU w.Q F- M LL W d W O o Z o U Z((iO'o Q Qcn OoF-N- �WLL(nU U N (n Q O) cc Q C F In N Z LL �UW=(oo Z <L6 ti o N(')LL U NW 1--o m zr(. Z<0�oQ �-oW m Z LL , (700= rnZo(4_0 ♦- jE �r (;)Ir Q W W ()0 mco r < W 0 F-- N LL � ZZCC) 0(J pUUW0 0 F- W o °��2Q Fr 04 ti O W F- (n a? a crLLo(7ri QONZf.- aU) O� J J Q_tiQco (rQ N= m U) � 04 0 a. :5 Cb Mo ZJUQ(�?~ > W m LL Z rn o>00=� aILLWHrn QU�-1(Li0 f 0 3 2015 v V ��. City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER FL Is*-- o g 99 (n 2 k z t' T R E S W E S T E N G I N E E R S, I N C. Washington Place Electrical load information. Residential (Connect load with .23 demand factor per NEC 220.84 applied • General Lighting and Receptacle 590.43KW X (.23 Demand Factor) = 135.79KW • Heating 644.30KW X (.23 Demand Factor) = 148.18KW • Cooking 2968.00KW X (.23 Demand Factor) = 682.64KW • Misc. (Dishwasher/Garbage disposal, Washer/Dryer, Small Appliance) 4266.50KW X (.23 Demand Factor) = 981.29KW Residential Load on MSB-1: 1,947.9KW Future Tenant (Spa) on MSB-1: 151.9KW Total on MSB-1: 2099.8KW Hotel/Avartment Common Space • Elevator (6) @ 40HP each 259.38KW a (Nema Rating/LRC not available at this time) 0 • Heating 87.24KW K • CoolingD 1049.68KW - • Refrigeration 12.00KW :E • Water Heating 30.96KW D • Lighting 154.09KW • Cooking 5.20KW o • Miscellaneous Receptacles 67.44KW w Kitchen Loads 21.16KW Small Appliance 41.6KW Hotel room Lighting/Receptacle 51.7KW Future Coffee/Retail 150KW m Car Charger 31.2KW m • Other Motors 339.14KW = (48) Additional motors, largest of the motors: 2 25HP 0 z Total on MSB-2: 2300.8KW m 0! • Fire Pump (1)15011P, (1)75HP 229.17KW (Nema Rating/LRC not available at this time) A v N • Generator 750KW w W 0 0 S:\2015 Seattle Jobs\81740- Washington Place Towers\Drawings\Electrical\Permit Set 9-4-2015\Elec Load Info.docx z z a � c � 3 3 c LL o U- d R C C C C' O d d w 0U i c_ c c p a � J N s d i w � N i a J J i Ill O. (7 E J Q R C1 E E J T N N R C i i m i a i M i cn O 3 a 0 U N E R Z N! 3 ca O O O O O O O O O O O O O O O O O O n O O O O N O O H o0 M b � N o0 O O O O O O O 00 10 7 N N r r O O O O O O O O O 0 0 0 0 0 0 Cl 0 0 r Ol O O O O ol O O O r N o0 r O fn N N � 00 O O O O N O O h h ~ w w w w w w w w a a a a a a a a U U U U U U U U v U U U U U U m U U d 00 o V v M kn O VI V1 �Mr .Mr ti O oo N O O Cl o O Cl o vi rn ON N 10 O\ O O, M M 7 V N 00 7 M M l� l0 7 � U U z H .a d U a U .•r F d O O o O N •7 7 Q\ O� �O eq N N JIoIoo0I0 010 C. 010 00100100001000010010010001000100 !E J i I i !s (7 O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O y J Q A U I N J o0 to N M to to t- to �o 00 O O 00 M O ID vl O O t- N N M M O M M O e! V N N t0 10 I --+ tl to N a\ M .-+ .. .ti n. � � b M M t- 7 V h t- M M M M O O Ot O` t� r- 7 7 Ot O\ E { to V' M M 00 a0 Nr N N PI N 00 00 el N O O 7 V O C. t-- t` O T t- to — 9 M M O 00 to 00 00 tt <{ to t0 E s W w M N 00 N N a, "o V to to 'o b O O t-1 '7 O 00 b b to to O \0 'o IA R M to th to M to M N O O M M M O M 7 O to to t` O [- to N t- t- 00 00 t0 �o 't It \o O, 0t .--t- R V' O O R V O O Oi O\ t- t- O O t0 �o 00 m L IL to � R 7 t` n to to O O M M 00 r- .-t M M 00 M 7 d' to to t- r try N m t- t- — :; R �o \o b� ti .ti .� N N N N to to t M J O O O O O O 0 0 0 O O O O O O O O O 0 0 0 0 O O O O 0 0 0 O O O O O i { y p, t, o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 E J Q J R U •L G1 (� to 00 .-a r N M to 00 M M 00 W t0 ON \o 'T N �D to to .-. to O tD try M M 00 O o0 O t0 �O 7 N O N �o M M R � a O� try vt N N r r- O 00 .-i -. o O O N -7 t0 to CT^ 01 t- to N O t0 to O O N N th O M M M O O 00 00 (n _ C4 M M M M 7 7 N N N N r�o N N 00 M M Ir 7 to to V — M to to .-i M M O O to tl- r, tf try to l6 !C i s Ot 'T o0 O 00 0o to M N t- to 7 to to ON O O% O to M O M -,r'R r- r- M M o c,4O { ch N M N M 00 'O o cl O M M M M t-y 00 M M o0 to O �O to N --� O try to to h N N 00 o0 00 10 N Ot to M N N ef• V b �o Ot a\ 00 00 7 to O O b �o 00 00 t L = d tT r,O, M M (ONO `R r O, M CA M. -I M M 7 7 7 7 b try to \0 .--� to to to Q It to N N to to M { r�7 J r9 W W W W W W a a s a a a a a a a a a a a a s a s a A77 Q �a Q �¢ ¢ U U U U U Q yQy U q U U U U U U U U U U U U U U .a L 0 0 N N N N CV W A M Ln W A W R1 W U U P� A U A U ¢ u U U d U N U U w U U M U U m w a U U U N N toz y It vn rA W W AW 0.1 Wzz zWz W W zWz N J O O O O O O O O O O O O O O O O O O 0 0 0 0 0 O O O O O O O O O O O O s (7 O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O y J p. J Q R U �r E Tf7 O O to !` l� <! V' O O O �o m 7 0 0 0 O N O O w 00 M M O kn vl to J to h 0\ 0\ b b N V) N M 0l b t- N N �o �o O O N M M M M y 't "t en n a "t m oo to Itn t, v v rn M 0 7 00 00 <t C .-. ,-. to w)m M M M : r �o %Z vi a o, v" 'tti in v i s 01 w 00 O �o M M N N O M M M 0 7 0 0 0 0 to N N N O t- N N_ CD V "tM 'ct M M M 0 �0 �O �0 �0 tn vl to v V 't Vn o0 00 .-1 r- -� rl rl N N O M C. O O R "t f ^ to 7 V 00 00 00 00 V 7 7 V 00 00 00 O� M M M L to 'n M M M M - .--� H t- h .-. R N kn vi t` t� = d kn vl N N 'r N N J O O O Cl O O o O O o O o O O O Cl O O O O O O O O Cl O O O O O o O o Cl O N Q (7 O O O C. O C. O O O O O O O O O O O O O O O O O O O O O O O O O O O O O E J Q R U N 7 '7 kn vl t- 7 t O O O M V'1 M O O O O 'O T O 00 00 M M O kn vl 00 00 M M M - 0, � In N O n b N r- �/t Vl O O N �o 10 O to M M M T V' N R V t? M V 7 00 00 R 7 0, O N 7 7 t7 M 7 'V o0 a0 0\ V1 (a V1 H M M M M O �o Vl 0T D\ 7 -It r1 7 V R C s _ 01 O O 10 h M M N N O M M ti r- M O O O O V1 O, t O r [� N N O 7 V �ni" M w 7 1 C0 10 Vt V] oc ol R V O t� M R N 00 00 I- ti' N N N ll 00 00 00 (? M 'Q 7 00 00 OD o0 M lD lO \0 O 00 W '-1 � 00 00 M �n N N N Sto h M M M to �-i �--i e-i t- to .-+ N •-• to �n t- r- IL '-i '-1 p i-'r 7 N N .ti N N M i g w m w w w w w m w w w 0 V 0� 01 x Q\ (� OX_� ya_� V X jC, M �o O, a C.� V > M .r N M _ u a� c�i��IM uva aaE �H m a m u u u w U w w a u u w U U u u ti U a V, z wzz w zw� zwz zwz zwz wzz w wzz �w� w m a a M j o CD 0 0 0 0 0 0 0 o O O o 0 0 0 0 0 0 o O o O o 0 0 0 o O o O O o O o i o 0 o O o 0 o O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o O o 0 0 0 0 0 o O O y J R f.1 �L d E (� to M t- t- t 7 V O �7 V T ON try V1 O M M .r t` t- O M V M M O ON O a as U O t, O t` J N M M M M to V1 to V) to V1 Ot of O1 01 b of 00 N V1 - ;r - .. b b N l w l� . r .-. .-r .. 00 00 rl C 01 h of W b b I h h to V) .--d' ti .y 00 00 R V rl .-. -It .-r 7 t- r.-to V) m M M M o s i 0) M V M M M M T o 00 00 t- r- '-t .-. O r 7 t- O 00 O t- M_ to h O 0, CD 0, R 7 04 O N O M N CD Cl CD 00 0o O O t` r- 00 00 C, T O 10 O N O Cl to V) — ,-. V t0 M M O C tl t- 00 00 b b 00 00 l� r- V) t+1 b b N N to V) t N N [� [� �-+ N M M to .-. N~ .� .--i V) V1 O O M M d to Vl 00 00 '-1 N N t M J O O O O O O O O O O O O O O O O O O O O O O O O O O O O O o O O O O O J N p_ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a J R O 0) c C (7 00 0o M M M 'V' 7 0 1' V' 00 DD .-� --. O M M 7 b t, O --� O b b O •1 O 00 0o O b O b J to l- M M M to V1 to Vl to Vl 00 a0 ON of � V 00 b O of 01 .-� .� b b N N t w tl 7 �--� O O o0 00 V^ M b O V1 b b b b m V1 VNi (n 7 'r V t rl 00 a0 O, of 00 --+ b [� t- to v) fn M M M .-i M M to V) en R C t 01 to M V' 7 7 M M O 00 00 to V1 as o\ o V V O ON O C - O to vl O ON CDO\ .� O 'r O .--� i U) CA-� W DD D 00 00 O O tl- t- to V) O1 CN O N Vl N O to 7 O O 7 <Y s to o h N N N O O r 00 00 T o� a0 00 !` h O b ut N N N N to vl 'e{ = a O r l� ti N N 7 7 ti D\ -+ .r �p ..r to In o O en M N N .r 'T to V1 .r .� N N M S4Jq ara' a'" ar a'"a 5 aa' arSa' Sar aT ar a"ar Sar x 04 x a a��� ,..��acqq �aq caq pap��psW� a aacacgqa aX aX aX aX U UdU U U U U u U U U Uu 3 3 u 3 u N L C 0 V b po o E- F+co .� m U U U xu >C U a w a w as W C7 C� x F F UD ¢ d cc W F F F F y m a ad a ad, iC iC X V J O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O J E E i s (7 O O O O O O C O O O O O O O O O O O O O O O O O C O O O O O O p O O O y J a -J A u d E (' l- f` O 00 W co O 00 ON O1 0 Q O ct 00 00 p .. O .� .-. O O O O ao DO O O O O l� [� O O J Q n Q Q 00 00 O O 01 01 �o �c f7 M 00 0o V) V1 N N O O 00 00 O O O O N N N ti N N 00 00 O� N N 01 w N N O V1 O h N N O N O N Q d- O O O O 00 ao O .ti CD �o 10 O M O M O O O N O Q V v v 00 W a m V V e 00 00 o0 00 N N 0 o N N Vi O O O O a V) Vl M M n r-�, M M %C o ti a N N eM M kn vi O O N N .-i Oi Oi N N rnlg� t- n a � M M M J O O Cl O C. O O O C. O O O O O O O O O O O O O O O O O O O O O O O O O O 1 s s ta Q, C7 J O O O O O O O co O C O O O O O O O O C O O O O O O O O O O O O O O O O Q J Vh N .r -� O 00 00 M O M Q V' 00 00 O to Q O V' O O ON ON O kn V1 .r O '-+ 00 00 ti r. O O O CD 00 ao O O O O 7 V O U, CD T N O O �--0 �--i [� (� O\ O� M M Vi Vl N N O O 00 00 O\ U O O 00 00 O O V N T (A M N N M M r1 .-+ 00 W ri _ M N N S 01 Q V' O -It O O O Q 'd' O N O N Q Q O T O O, 00 00 O ti O M O M �D �O O O 0I l0 Q fn cl 00 0o O� D\ N N N N 00 Do 00 W ti -. C Q\ .-� r. V) h O O [ [- O O T Q� V1 h �O �O M M h l� In O\ ti L a. N N to O O '-1 00 00 fn M �O �O \o 10 '.j en m ~ M M N N N N M M Cl) s o aX aX 'aX aX aX aX a� aX aX aX aX a � U N U N U N U N U N U N U N U N U N U N U N U C O U C1:47 C�7 C�7 C�7 F F�-� Fes• aroma U u as Ewa �a �a Ua�w �w U 44 U W U 7W U w w P: U W X X X X a X W X a �' w w a X? C S X CS U u vaas '. .. '. a oa. Ln R FF F+ z z a a a rx a a a rx a a a J O O O O O O O O O O O O O O J O O O O O O O O O O O O O O T a � a £ C7 T n t 0 oo o v im 0 0 3 J Vi N Q N N m- lO lc N N -t oho oho 0 0 V7 i N vn 'IT V V 7 to 1n .-� .-r O, Oi M m tn v) cd �+ w N ci � ti N w N N O h O h o to v1 Go00 M M O oo O oo oo.0 o 0 a a, v v '. _ a o" Wn vi in �o a v W o pa CD & Iq '� a� . dwwa:.9C:> Ej o C. 0 0 0 0 0 0 0 0 0 0 0 0 o j= O d CL ° " c i ci d rr C a (J J O O O O O O O O O O O O O O Y E Q J m LL U � y w E � O 3 7 A 7 tfTtf�� N LL m m O. LL Q ('J M M O to r b 'o O N O N W E J h h O O M M O O V N N M M O O w00 cl cl CO)�O \o M M 00 00 M M rr .-+ M M L fp � C O — U i O �n O v1 to v1 er 7 O N O N i N l0 M M = 00 In v1 Wi h h of OO w m O O N N CT C s d N N R 7 v C R .-; ..; .r 7 V v; N W a co a E-" aQaq s a C¢Wgi pQapQ�� pQ �7 U U U U U�D U U U Q fn C � O Cl 3 ci O O N d N N N a.v � J % z��> 41 a x x x x i ¢ ¢ v� UU Cl) y 3 3 U U W U y x O coo C7 5 0 a A c L' oU.. d d d w � N N a a C1 C C C J _j O E d £ x x x N L t J O t c c c o IL 2° 3 0 H co J J cL H X m x w a a J O O O O O O J 1 i (7 O O O 0 0 0 y J C J E Q R U GY E E N N s 1 N M � O CD l0 N N O O � M J O O O C O O J 1 1 N (], O O O O J Q J R U N E 00 0o O [— O l� o0 00 in b C4 C b b N N R �C N M m O M O M L 7 7 p O M rr'I- � rr7 f�J 1 w 0 X X U 3 U al 0 v U U w w X w X a rn m x x E F F (a m N O O O O O O O O O O O O O O J i O O O O O O O O O y J EJ U � U E 'Y E '3 (� ti r N N [- l- R 7 O In 1/1 O J y ao 0o 00 oD t� t� M M ao 00 N N 00 0o to vl v� v1 O O t� t� Cn _ O� to n Co 00 m d '� Vr .•• N I i 0 d N U w O V i LL N V ; d �1 a0 00 01 O1 e} 't 1n �n .-� N N M m .y tn v1 O O O 01 01 O N N y, U w 10 l� l� t ^ t� 00 o0 00 Oo O O I ' y t00 10 10 In ti c� 7 W C Q] O aS p .�. N � Cc. k+ Pi rC- � C J O O O O O O O O O O O o O O O F R O d Qi OCI 3 w y a. V C Q. C9 O CDo O o O o O o CD O O O O d m to3 ` Q J a O L O U U. m > V 41 £ C y . L r' 7 f0 7 T = L l6 l0 N w LL m m O. LL Q J l- [� n N N [� l� M M O M M O £ T ,.y 00 DD 00 op r n M M 00 00 N N DD o0 N" 7 V' O O [l l, 7 7 L f0 _ C O - U d oo x <r V M O oo M M H 7 7 Mi M LL M 'ITC W IL d H i ar a' a'" a' ar ar 44 tm e � w E in (A u u u �D U N L w U a , coU O U U U O .. O L o > m 3 (� Q N C7 t C O d d J J Q- d d w `� N E Z G w C C C O 0 v, W � W z W z W z W z W zQ L _ m O a a Li 1- to J J m F- X m aa. a 0. p J O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O J i (J O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O y J t]. J E a U 0) i E (� O O �o �D O O O\ O ON O t- t-, O O�o e r .--. O C O "t V' 7 O N CDN 0 0 0 �O O t- l� 10 �D to Vl b 10 O\ 01 fn M �o 1000 m ON O\ h s 00 It V to 00 00 'r tl rl Oi ON O 00 .ti O\ a 00 o0 00 ti N O O O O 7 V O O N O N O 00 a0 O �D O b b �D O .--I CD 0 0 0 a,O O\ t- t` O .--1 CDfA enM ? v_ 00 00 a rn e .- .N-. N N o0 oo �O 'D n 00 W c t` to V) 0 0 7 00 0o rn rn o0 das M Ol 'O M .�-. fV .i 00 00 .-i to ti M �..� J O O O O O O O O O O O O O O O O C. O O O O O O O O O O O O O O O O O O J i i (A Q 0 E O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O o O J Q V N d E O 0 0 0 10 10 O O O O t- t- to O Vl O 10 �o t- t- O to Vl �O O �D \O .r .-+ O C' O M M O N CDN ON ON O �o O N N N N l� l w a0 00 O, ON V In dp 00 t0 10 l� � 00 00 00 00 00 00 a O� t- 00 (n to Vl .-f .-. O O n l� .-i .-. to Vf .-i O� O, .-+" 00 00' R !C i 01 O �O �o O 00 00 O O .-y C - O N N O �o O R t 0 O O O t- t- O O� O O, t- t- O 'r O = o . to N N a v M M rn rn 00 0o to .n to Vl It .-, N N o0 O0, �o �o r` t 00 m t� t, M M o" O 7 7 Oo 0o M M 7 i a a m a to N -00 w 00 i tn ri a m ei oc .r i ca w ww www www wt w ww ww w ww ww o a as aaa aaa aX ay� aX aX a" aX aX w a u ¢�a -C � �a�a¢ �a3 Q3 �3 -< 7 U U U U U U U U U U N U N U N U N U N U N U N U C V00 00 !Vy7l t- W�o .-. .1,�� tyy-�� U U U U H H a H H H a H o U U U v P4 � w a U w www � U W W p" X X X X oo X oo X In p, '. '. to to r E4 E4 F F z w w w a a rz a a a a J O O O O o O O O O O o O O O J E 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a -J Q Q >, c10i U - N d E E •3 r r v v r o 0 0 o N N r r J N N r � M M o0 0o .-1 c� rw N N o0 0o M M v v 00 o0 t� N N � y � a v :03 o C d � �+ U cCC (•) o N M M to Vl 7 a C3, M M O, p, M M �. w V asL en M IO lO M M Vi l V� tll O O h vl y ti i a o o a o� o o a o, 0o a 00 00 00 00 U i W W z (]j O O M Qwwr�r. C) 0) J O O O O O C. O O O O CDO O O F- Q d 7 ' � C O U a o O CD O O CD O O O O d c an d d c Y E J 0y. o CDo CD O U m O L (3j LL U d LL m in LL LL Q E J O O N N O� O� O O r � O O 3 N r r 00 oo Io l0 00 o v It_ V� t _ v v_ 00 00 � t- 00 0o ro c- r 10 �o r r L l6 _ •C U ! ! N l0 rl N N M M VI vl O O N N N N v1 M M ItV1 't r ofr O)Q� M M d' � t a o o a o 0 o a Cs 00 00 r 00 00 LL M w a a �, s ! w �n p 3 U U U U U U U N •L ' w C C�1 7 O R L O O O O O O O U ' N zz��� N N N N N N d V ` N N M .M'. 7 O o 0 0 0 0 0 v 0 O .+ p O C w L a VJ 0.U1 0.Ul 0.Ul O = N U' 3 a �9 U LL 7 2� F- r_ C d O li 0 W(Dd d d•L N d O d t N N IT N IT N ITQ1 �' 'L J 0 O ry 0 � O O N N t7 M 'I •O Q. d d .p„ L H E Z E d OD d d O C 0 0 0 0 0 0 d O s` C C c o m ,e 7 0 U 2 X m O o O o 0 o O i J O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O J { { 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 y J 0. J E Q R V IF E(•, O� O� .� --� ri -� b kO l- l- \0 NO 0� O\ \0•D N N t 7 CD00 w CD CD M O O M M O O D\ J r b b b b V) Vl in V1 -! 7 v 7 M M �r V' M M 00 00 0\ O, l- of N n n r n 00 00 [l n 00 o0 l- t- 00 0o r n 00 0o N N N N l0 �O V) n V1 \0 lD 00 w r n 00 w n n w 00 [l [, 00 w r r- M M Ih [- R V N1 &) N %0 �O N N N N N N N { 0 M M lam' l- 'tT d' 'O b kA .n \0 �O o0 00 [, h . r --� M M CD01 ON O O b .D O O .r .-+ O CD W M M O O •O 10 Cl O, V) Vl [� 1, m M in •/1 N N M M -T 7 N N N N V1 07 O O 7 b 'O M M b M M N N '= 00 00 O O 0� O, O O C� 01 O O O, a, O O Oi O\ O O ON a, r r- b ID V1 { a rl N '-1 '-1 I� [- IA .� M ul V7 .n V) m J O O O O O O O O O O O O O O O O CDO O O O O O O O O O O O O O O O O J { N O O O o O O O O O O O O O O O O O O O O O O O O O O O O O O O O o E J Q J j6 N f1 d E C, ON N N 7 V [- O O 00 00 N N 00 00 'r 7 M M O O O O O t- [- O O �O �O O O .r -- O"T V) Vl M M - Vl N N R V M M 00 a0 n r- N N 00 e0 N T y r� [- l' r- OC 00 r-� 00 00 t� 00 00 00 00 O� O! %0 lO (a M N N M N b�o 00 00 r r 00 W r r- 00 0o r r- 00 00 r r- R V N N N N N N N R w 00 DD 7 V V) v V1 Vl [, l- �0 �O O O t-- r- It 7 00 m O kO \O O O fV N O O M M O O 7 (A �m b OO 00 O1 ON t- 00 w to Vl t, M M kn Vl M M N N O O O1 O\ 00 R O� cl� N N V1 .n N N Vl .n N N V) W N N Vi .n eM M M M I� l� M n O L m O\ 0\ O, %0 �O V) un V7 Vl Vi V v = M ca { W W W W W W W W W F W W W W W W W W W W ia� CaCqq a CaCd� a a a papd� papd� ai.� a a ap� a a ap� a s ..� 3 U U U U U U U U U U U U U U U U U U U a c U.A O h O Vl O O_ N r M N_ M M_ i N N N N N N N N N N -� - �-+ --� �-+ - 7 M M V' V' l7 �O 00 00 A N N N N F N N F lo Q O O O C. O CD CD O A Q A Q m A Q m �� U �� O U U U U U U U U U tn Q Ci E N O V) O m O V1 O kA F O fV enQ E N N N N N N N N U Z en m v v o b 00 00 A F F F F U U U U y o 0 0 0 0 0 o O G � cn Un V) V] J O O O O O O O O O 0 0 0 0 O O O O O O O O O O O O 0 0 0 0 O O O O O O J s i i i0 0 0 0 0 0 0 0 o O o 0 o O O o 0 O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O o a J Q J Q 7a U G1 E0 T 00 7 ON a\ O 00 r r- O O en M 00 T 0 7 0 [- O O l- N O O N b O O �o h 0 J N H O b �D O O U l� l- b b [l [l N N kn vl N N O � N N 00 a0 ti 00 N N 'r e4 to vi It O O 7 V IT [t M M O O M M to h rl try rl H 'y i 0 O O C' 7 O O O O O O to O 0, O 0, O N O O N M O O M 00 O O oo -V O U) �A r r1 �O G M M O O V1 v1 M M N N a,O� e-1 .-� �f V rl .. enM V' to N Vi t Vl IA t!1 b b b 10 M M b b ti .-r to In Vi h .ti �r � M ! J O O O O O O O Cl O O O O O O O Cl Cl O O O O O O O O O O O O O O O O O O i 07 Q (' O O O O O O O O O O O O O O O O O O O O O 0 0 0 0 0 0 0 0 O O O O O O J Q J lC M U N O O on t h O O b %D O O �o N N O O b O �2 O .-� 0 C> N O O N .-� O O -. V1 O N N N N N b M M M •-1 ^. V b �O O O V' V O O b �p O� 0, kn 0\ (n CA.-+ --� 00 00 �D b N N 0\ O� er V v 7 O O O M M M M M M N N N '-1 '-I �••/ A .E s N v 0 0 l- r- H .--. O O N N O O r h 0 0 V1 O O a0 O O oo 00 O O oo O O 'A 00 N N 00 o0 to V1 h M M 7 V <F f6 L IL O N [l I- -It 7 00 00 N N 00 00 C� 0� b �o V^ h M M V h M M b \O O O b O M i y W W W W W W W W W W W W W W W W W W W W W W W W W W a w w w wwco m w �� aawr� aim a c 0 V 7 V1 (� h M 7 M N N H t b V' N N H 10 a0 b N N O 00 a0 N F O h O_ N N O h N_ N N CD h M_ CAN Cl N N N N A Q a m A A a A Q N Q a M M� 0.Q1 QW 0.Q1 W CO U Pa F0 W W U U o o o o o o o Cl0 V o o o o U o U U U U U U u a E m F F F F F w 4 w 4 &n U U U U 0� A A A A A I x J O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O CCD J i s (7 O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O y J p, J E Q R U ; E (� O l� ON O O Q� l� •r O O G �O tD 'O O O �O - 0 0 M M O %O O 'D R V O O, O a\ N N O 'O O J oo oo l� tl t N N r-� O1 Q\ ll:� T Ol -. N N Ol ol t- 00 00 to V1 00 y w In h � In vl kn vl N vi .-i ._-i t- O O ' b tr t- N N O .A s N N N N N N N r1 s 'A CD -It 000 CD 00 M CD CD N O CDN N Cl O N M M O t0 O t l� O 10 O �O to h O M O f0 cc�/? N �O 10 M M 7 M M Ol Ol N N 7 V N N Oi N h IO �o It a i 0 � H I N N_ ti Ol b t a Inh k V1 kn h tn h kn h h Vl M M V7 Vl en � M tn to J O O O O O O O O O O O O O C. O O O O O O O O Cl O O O O O O O O O O O O J 1 Ul Q, 0 O O CD CD O O CD CD CDO O CD CD CD CD O O CD O CD O CD O O O CD CD CD O CD O O CD O J Q U Jh 4, CC O Vn as O CDON ON CD CDQi O CD O CD O O O 00 00 O %0 CD�O %0 �O O h O t, t, O N O C O\ N N ti .-+ '-I . -� .-1 .-._ 00 00 O O '-1 %C 1p G O Cl 'IT V' 00 00 th t- t- T U) (A O 7 V 'ITV 7 7 7 7 to h V V V V It 7 In M M M R V R V N N - N R N N .-y N N C 0 O O fV O O N 00 O O 00 kn t- O 00 O oo 'O 'O O t- O o R 7 Ln v1 M M 00 00 V v� N N v v_ 10 10 M M M M 7 7 [� CL M M 00 0o f7 M r Cj M to n M M t w O M �• '• r. '. v v .. v v '. v v '. N W W W W W W W W W N W W W W W w W w W w W w W W W g as w m aaa w w aaa a w w aa aaa aX aye aX aX aX a ¢¢�¢ w w w w w w w Q 'C U U U U U U U U U U U U U U U N U N U N U N U N U C V N N M O 10 C. m O O_ O_ O N N N_ M M M NO u N � d. � N N � � U ao 00 U C>C, Q o o o o Oa Cl o W o o o o o U o o U o o U _o _o U v UX k UX X a W U U U U U U U U U U U U 0) O O N N N M E N en 7 �p 00'ji o 0 0 0 0 o O O Cl0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 0 0 0 j I s o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N J p, J E Q R V L �() b 00 t- t- O O, b O b O O O t- O t` 'T 7 O 00 O 00 C\ m O O O O b b O M O M J N O O" l w l w t- t- O C O, m 00 00 to Vl N N 00 a0tn N N N N clC N N ri b b DD 00 b b N N b b T O, b �O 0 s N N ti R V N en rl enM e1 N N .-. d M M. M O O\ O O, O O O O O O M M O R O V m O\ O r1 O --� to v O a\ O a, N d Ol b b b t- t- V V to V� O C. N N b b t- [� O O r-1 E t o. M M N N b O ri b O N N b lD kn vi Vi .n .-i lO lc M to t? M ON ON .n , v in .n v 7 [� [� Vi v to vi cn M n ., b b ., b D n v ., kn n J O O O O O O O O O O O O O o O O O O O o O O O O O O O O O O O i N {y O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O J Q J R t) d EC N b b O b O �o O\ O� O b O �D to Ln O b O �O O O O b 0 �O ON ON O b O b C J l� t- t, b b CT O� [� [� .-1 -+ b l0 O O_ 7 V 'R V R 7 7 'R 7 00 00 7 N N .ti M M M rl N N .--i R C d t- 00 m O O� O ON N N O N O N N N O 00 O oo 'V 7 0 O O O 0 0 0 M O M N d t n r to h N N b �D l� l� O O V) vl b b 00 m O O N N 't 7 00 m CD b b N N 00 Qo .-+ -+ C O n a O M m O O b \D en M \O 'D M M V) .n M M to Vn M M M i ! x x x x x x x x x x x u u u u 3 3 3 N 3 3 U 3 3 3 3 ¢ 3 U N U U N U N N U N U N U N U N C O M M Vt 'ct 7 b 10 b b W 00 00 a0 H H O F F H O F H F O F H F O F Uw �w Uw w U w X X X X U X X U X X U X X U X a W W W W rA a to F F F F m h J O O O O O O O O O O O O O O t J t (J O O O O O O O O O O O O O O T CL J N Q U •� EC G _.'�.. 0 00 00 00 00 kn N N N W 00 3 � y V 7 T O� 7 0, 0, R C 0\ C, en M w y i 0 0 •� �, I �+ H �+ w N V ` W h n n n o0 00 �o %o .r h t� N N �o �o a V %Q �o b b to � h n to vi LO J t = m to v o o to v C C vi vi o o W v h •� �, ` a 00 00 06 00" 00 00 00 w 00 00 00 a 00 00" 7 GG t� i O O tn �wwrx�� C J O O O O O O O O O O O O O O O F R {y N 3 y � a O O O O O O O O o O o O o O d 7cc L p 3 R m j VU. � In cc Gf 3 3a i L 7 �• LL m m ti LL Q nr i+ £ J N N 00 00 N N OD OHO .h-1 00 00 .may 3 a y c c r,:, n v c n n v v t- n v v Q G7 h t- b �O t` n b b r n�o b n n •L R _ C U w W f7 to n n b 10 — .. O CD Vn Vn 7 V 3 L 7 - C, G 7 V 0� C� If V C C 7 V a ot" 06 r. n 00" 00 t` r- 00 0o t` n o0" 00 LL t M LLJ a M a y t s a Q U U U U U U U •` R N N O O N N O U CD c:l N N N N N N N �i o 0 o a o 0 0 o o PU0 U u u •� R C7 3 U U r LL O LL. H (a d .O. d W �+ L R C C O E ti 0) V C J J O N N N N N IT ` ai J a 0 V w d R �n O Q as .O y £ C Z .. ., .. .. .. .. ., E `p1 Im y a C 0 0 0 d O L C c c O A— 3 0 0 0 0 U ►- N J J F" X Ino o O o CD CD o J O O O C. O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O i i (7 O O O O O O O O Cl O O O O O O O O O O O O O O O O O O O O O O O O O O y J O. J E Q R U �L d E( j GT O, 00 M M O O O M M O O v Y' O O 0 0— N 00 N N O O N en 0 0 0 J 00 r O m oo M M v_ v V v v �Q 10 r r M M oo 00 o0 r r b 10 V1 N r Io 10 0 0 I 00 00 0" o v cn" � 10�D 00 -i 00 00 .: 00 00 00 i M M N N N N N 01 O O O 10 0 0 to vn O O e} V O O N N O .ti o0 O O o0 V O C. 'ct O O r O O O N h r r v V �O 10 C� cl M M 00 00 N N �O �O ti .. �O 'O O O L d. 00 W R V M M .r O Cll- r � M b b b 10 10 �D 1O 10 J o O o O O O 0 0 0 0 0 o 0 0 0 0 0 0 0 o O O O O O O O O O O O 0 C 0 0 i H Q () O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O E J Q J R N U 0) E 00 00 t h O O v 7 0 0 r r 0 0 �o 'O O ti 00 O O 00 N O O N �o O O 'O O O O O J T r r r [� N N v V o0 00 a0 00 P1 M ao JO M M 10 T C i0 10 a C �n vl N N O N N O O N N 0T O, .-1 -� 10 10 O O ♦-1 r. O O .-� .-. O O .-y '. O �..q R C i m O O r r 0 0 v V O O N N O O 00 O� O M M 00 O O W T Cl O O� e� O O N O O O = t0 t 00 00 r r W" .-. V1 vi V) vl N N 00 m CT C < t V1 �/1 V) vl �O �O V' <{ �O �O of �OZo en a l� r 74 v v 7 It v v 7 V v v M M v v r r O O .. O O .. O O O '. M i 4 i .9 4 4 .9 i 7 .9 rr7- a N N N N W W N N N N 'N Ili s a aapa N N N apar��pra�� N N ar�a�aaq1 N apaa N d papd�Im H¢ d �a�gqapap�� d d¢ �acy�aa d d d pascqq Q d d d d Q Q d d Q d a U U U U U U U U U U U U U U U U U U U U U c 0 U h H r r oo r 00 ao o r N N •�! �O O „u r� N 00 Oo ON W CO P� U W W W U 0 0 CQ m C> ro O OO U N U U O O U O U U co U U U U U U WU U E N N b r 00 Z E• F F F d U U U U 17+ a r 00 3 c 4r�i o-�r 4 0.m- U U U U a a A A x J O O O O O O O O O O C Cl O O O O O O O O O O O O O J i i : o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 y J E U G! E (� M Vl f.'I M O t-- r- 7 O 'R 'ct h t-- O to -' O O O O d' 0 7 'O %D O R 0 7 J 7 I .-. V) O O H7 M t-t .-. t- t- N N N N .-i .-. Y 7 t' O� N N N N t- t- N N N N .� to ut N N N N .-t M M N N--� N N : N l� N N O %O O 10 O O O C - O O O r O t- O O O M O M m 00 '0 7 V OO oo M M L v o o o t` t w a C t r t� a m n a m r = a o r+" O00 o . + tr t- .-i c .: to n '. to n to '. J O O O O O O Cl O O O O O O O O O O O O O O O O O O 1 N O. (7 O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O o 0 0 0 0 0 J Q J E U G1 £ C9 o V1 t- t` O o 0 0 to v 0 7 0 7 t-[ O t- o t- t` o .-t o J U) cl N N 00 00 00 00 ti O O M M t-[� .ti 00 DD t- b b [� t- N tO �O 7 N _ O O O N N r1 .-. '-t O O N N O, t6 S 01 N R 'C O t` O t- to V) O w O o0 %0 �c O O O Cl t-- t- O r•+ O --- N M to V) 00 00 O O t- t- to 11 h O O tO t to O 0 o N1 m tl t- O O OO oo N N O t l t w CD to h N N t-:, O M M N N r O O I 3 u ¢ u 7 Q 'i U U N U U N N 3 U N 3 U N 3 U N ¢ 3 U N ¢ 3 U N 3 U N C O U F F O F F F O F F F O F F H O F actc aria actin 50: a: tz� U w LG w U w W w U w W w U w U U X U X X U X X U X X X U U U .. U at to to a c t- 00 Oo Eccl F.F 3 m w WF X [Fri+ X wF X wF X wF W tEz~ X wF w M v 0 m G1 V tQ IL M O O r <.i m O a J O O CD CD0 0 0 0 O C.O O O O i L) O O O O O O O O O O O O O O T J p- a� Q U� E T N N J M M M 00 00 N N as { to i d M M M M 0 0 h h r �o 00 00 tA V) v ;r 0\ ON In a� ON In `o U m { t M O O cn w t V 1n Vl C O v! V1 y h r. � S, j n o o" 0� a, o o" or a, 00 0000 0 00 00" V] P� m T: GQ ° M N ' ! J i O O O O O O O O O O O O O O O H Q c y I cigo V w 7 3 C. (7 O CDO O O O O O o O O O O CD _ rr N N d C E m `. m T �? J Q a o t U ti co m m u O N 7 N T N LL m m G. LL £ O, a\ b 10 O\ O, 00 goo a0 00 N N 7 7 O N N a, - '-I -+ O O h O T to h h 00 oc lc � o0 oo I_ v h h V v N 00 0o r- r- 00 00 tr r- h r-10 �o r-h -L N O — U w N 00 00 h h O O O O al a, M M M M � NVl t N N Vl Vl 7 V T a� R 7 c0 o. O O a� O� O O a� 00 00 [� r,00 00 LL rf I.L , ui a a �, ; s 4 .9 ,s s I 0 w i c In a a a a a a U u U 3 U U U U ._. o i ° ° N N N U CD N zz��� _ N N N N N N O o 0 0 0 0 a 0 0 W W W U U U U U U U tll LL o IL w d ~ 41 W C i w c C E if d i t J J J O E N N N N N N N p- IL U 0 N w w A O C cV N th en a 47 {N C G Z — '-1 �-1 — G! 01 N N O C 0 0 0 0 0 0 0 p C_ c c O c` w 3 U F- (A J-i 0 J O O O O O O O O O O 0 0 O O o O O O O O O O O O O 0 0 0 0 0 0 0 0 O { () O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O y J p, J E Q R f.1 d i E (� O� D\ .� N b h h �O b T O� �O b N N v r O = m O O M M O O M M O O O, to vl in Vl 7 V' e 7 m M R V' M M 00 00 O� Ol [� h V• 00 Do h 00 o0 h n 00 0o N N N N kc M Vl V) h 00 00 h h 00 00 h h 00 ao n h M M h h <r d- M M eV N N N N N { d M M Ih h V^ V' 14 10 to Vl Im b w w h h .-i M M O O\ Cl O O �D In O O w M M O O tO b O1 O\ 1n Vl h h M M to V) N N M M V' V' N N N N O O 1~n R O O V' V' l�O M �O �O M M O ��O M M �O 2 O M O� T N N M M It L 00 w O O Q� O\ O O O\ Q, O O eT a\ O O O� O, O O O\ O\ r n b a r+ '. ., h h w to In R In M J O O O O o O O O O O o O o O O C. O O o O O O O O O o O O O O O O O O { { N Q 0 O O O O o O O O o O O O O O O O o O O O O O O O O o O O O O O O O o J Q J R N f.1 .41 O, O\ N N V' 7 h h O O = w N N 00 w V' 7 M M O O O O O h [� O O '.0 B O O 10 \O V' V to V1 M M to Vl N N -V V .-I -+ M M 00 W h h N N 00 tb N N co r h l� h 00 00 [, h OD 00 l-0 a0 h 00 h [� 00 00 O\ O� lO b M M N N e? �O 00 00 [� h o0 ao h h 0ao h h 00 m h h M M �O �O 7 7 M M N V' V' N N N N N N N R C d w w V• V kn v) V7 V) h h kD �O O O h h V' d- 00 w O �o B O O N N Cl O M M O O V' { 0 10 10 00 m a1 T h h = 00 4A Vl h h M M tn Vl M M N N C. O 01 O\ 00 R O\ O� N N Vi Vl N N V1 11 N N Vi V1 N N V1 Vl L h h O O ON O, O O eT U O O O� O, O O CT O� O, O\ b � V1 V) In Vl V7 ' a "'� "'� . r V' V' R 'V V' V- V' V' V' 01 i eA W W W W W W W W W W W W W W a W W W W W a a a a a 3 U U U U U U U U U �D U U U U U U U U U U .Q L Q U N O N O N O N O N N M O N C. 1 N { V M M �' -T �O 'O 00 - N N F' eV N N N F Q O O O O Cl CD CD Cl Q Q m Q A m Q Q Cl ClO O O CD CD O A A U A A U A A U U U U U U U U U U N A Q� N e1 O V1 O VI O V1 O VI N N N N N N N N U e-i H .r �•.� Z 'IT en eh v v b IL cc oo A F F F F U U U U O O O O O O CD O ClO O CDO O C. O O O O O O O CD CD O CDO O O O O CD J i () O O O O O O O Cl O O O O O O O O O O O O O O O O O O O O O O O O O O O N fJ 3. Q A U 0I E0 a\ 00 7 O\ <7, O Cl 0 r r Cl 0 M M O O 7 0 [t O r O O r N O O N %0 O O �D r O J O % .y o O O� t [� b 10 r r CA N V1 v1 in V) lO N N CA N — i N N '-+ N kn Vi O O R 'R O O N -+ O O '7 O O O O .r �--� O O to V1 O O a, O O N O O N M O O M w O O ao et O l0 i c Vl V '-1 b M M (n M O O O O — �--� Vi V1 M M N N ON a� -ri 'T V M M Vl N In V) VI h b �D %0 10 b 10 IO i0 ��i .-. .�-� � M J O O O O O O O O O O O O O O O O O O O O O O C. O O O C. O O O O O O O O N o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 J Q J A M U G! Cl O kA vl tA v] O O IO b 00 N N O O b C. O '-I 0 0 N CD O N " 0 0 kn O T N N N N V' 7 N (V R t 10 10 fl] Nl fM M .-y--� �O iD 7 7 10 (n N N ti N N M W M M �o 10 M M M M N N •-� rl .-� 'y A C 0 7 0 0 r r .r O O N N O O r r 0 0 kn O V) O o0 O O O O .-. 00 0 0 00 O O (o 00 r r R V N N 00 Do V1'7 ty' A '= IL O V1 v [� tw C' v v W V) 00 00 v v N N 00 00 v v I I l-- r v v O\ T \0 �o v v W Vl M M '. W V) M M - \C �D O O %O O M i N W W W W W W W W W W W W W W W W W W W W W W W W W W c a a a a a a a a a a a a a a a a a a a a a a a a a a g '3 wCCgqm Q Q Q w Q w��qqpp�� Q Q¢ tCqq[�gqw Q 6 Q p� ww Q Q Q Q Q Q U U U U U U U U U U U U U U U U U U U U U U U U U U .L C VU1 V .. V1 .--� M M q' N F '0 - 'D N O 00 00 O V) _O N N O V1 N_ N N CDV) M_ N N CD.-. N N N N N N N N 1-4H U U U a A Q a Q A a Q ca a N Q` O� O� • 4 •Nr .M-. .�. fQA U Pa Cl W W W W U o o o o o o 0 0 u Cl 0 0 O o u o 4 U U U U U U U E tn Z 1-4 1-4 F F F U U U U U U U U U i J J O O O O O O O O O O O O O O O O O O O O O O O O o O O O O O o O O O O i i i () O O O O O O O O O O O O O O C. Cl O O O O O O O O O O O O O O O O O O O y J Q J E Q OS U Q) E E () O r O1 O O ON r r .� O C> �o �O �o O O %0 N .-i O C> O\ e i M O ON %O O �o R 7 0 O, O M 00 N N O %O O J y oo 00 r r r r N r r T `c `o O\ ., -" N N ^' -' a of r r 00 o o kn vi r r 00 o i i I -+ to Vi en v1 to V1 tn V1 b �o N N b �-+ M M CA N �O �o �-+ eV N N N N N i i 01 O V' 07 O O 00 M O O M N O O N N O O N M M O r o r r r Cl %O O In vl O M O o i 07 N vl �O 10 M M M M o\ of N N R 7 N N Ol of Iq v1 b b R 4 N O� t i a -n h h �/'1 kn vl to �n kn h kn Vl en en inVl rn en H i co '. '. en kn kn kn 0 0 0 0 0 0 O O O O o 0 0 0 O O O O 0 0 0 O O O o 0 0 0 0 0 O O O O O j i i i y p. C!) o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 J Q f0 'I U GC1 C O vl �h O1 O O ON O\ O O 01 O o 0 0 O O O o 0 0 00 W O \0 O '0 �o �0 O IT kn O vl r r o N O T y Ol N N_ .--I 00 00 O O r1 --� lO'It o O V V 00 a0 M M r r 7 V r �--1 V 7 -n v) N N V V ti m N N ti N N N N N 07 01 O O N O O N 00 O O m .-� O O 'V 0 0 7 '+ O in O �/1 r r 0 00 O m b �o O r 0 W m 7 lo Ln �/1 �o �c M M �o �n ''-1 .-. �o 'o 00 00 en Ana N N v 10 10 r r M M oo M M 7 7 r L a o en e+ c+i n en e•i r v' v v en en '. en m m r en m o" i SS a''Sa'" a'"SS SSS SSS SS SS SS SS SS S y w w www w w w w w w w w w w w w w w w w a s a a a a a a a a a a a a a a w a w a w a w a g m a m w ua m w m m ai u m m X u 3 X u 3 X 3 m X 3 X u 3 w ¢ U C) ¢ ¢ U C, U ¢¢¢ U U u ¢¢ u U ci ¢¢ au U U U U N u a ii N Q u � L 0 v'1 V O In M O In V O v-> 10 O V1 O C. O O_ O_ N_ N N_ N M M M i v U n cn v v o o Oo C? F- F O F F F U FF F• F- U d ¢ d ¢ d 5 d d 4 •5 a � ' o .5 o o_ o_ o o o o o_ UU w m w U w w UU w � U U U u im U 3 E 3 3 3 3 a 3 X u X X U X X U U U U U U U U U U W � W � W y O O eV N en M E F F F. Ftu F F en U U cc U U J O O O O O O O O O O O O O O O O O O O O O 0 O O O O O O O O O J e [i i i Cl 0 0 0 0 0 o O 0 0 0 0 0 0 0 0 0 o O o C. 0 0 0 0 o O O o 0 0 y J p_ J Q R U N E T(7 �O 00 t- t-- O O, O1 �O O �D O CD O t- o t-- v "r O 00 O 00 O\ rn 0 O O O �O cD O M o M J fn O r ll t- t- O O O, O, 00 DD try h N N 00 m N M M t- r- O O try to b b 00 00 b b N N �O i N N .r ti M M .-t M M .r N N .r .-. i d N M M M O O, O U O O O 0 0 0 M M O v O V T O, O CD to — O ON O O� l0 01 �O �O 1p f7 M t- r- 10 �O Q V tG lO to v1 O O N N b t0 tG 10 M M t- to to O O et 7 — .r to L d h b b to Q\ to V1 to to l- h to to t M to ti b „may to to to to to J O O O O O O O O O O O o O O o o O O Cl O O O O o O O O O O O O J i s i s CL (7 O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O E J Q J R U •L N E N �O �O o \0 O �D O\ O\ O - U �O O �O t- to to O �O O �O O O O \0 �D CD 'ct C\ ON �O �O O M c+t r- V V '-1 � to to b o 7 V O O .r .-. 'I- V v V .-� .-• N N V V b�o en M 7 '-1 v V' cn M ,r er M M .zr-I 00 N N ti R N r o to to O'. O Oi 10 10 N N O N O N I�O N N O 00 0 oD v v Cl O O O O O O M O M N t` N N l w l� O O to to 10 W a0 O o N N 'IT C Ob 00 O O lO lD N N 00 m ti -+ O O ON O� L a O en M O O b en InM Cl) v v - v v i 3 U 3 N N U 3 3 U 3 U 3 3 U 3 3 L CA U CN U C V M v EM- U EM- H H U Ev-� F F U [mot F Ems- m o0 X U X X X X X X X X U X U U U X a a cc a C40 E F F+ F H F F F F 0;F R z aw�ry m Fad wx Fady �ay wz wa �xy Fad wx J J O O O O O O 0 0 0 0 O O O O : (7 O O O O O O O O O O O O O O Ul J Q, J N Q V U N E 'w T (' O �O l� oo a\ .� vl 00 ON 7 t, 00 h •3 J 00 Z O N h .-1 V1 00 �O Oo V rn 00 n O c� <Y O U) �w•=� w E c 0 m cd -y >, E 0l 7 [- O, 'A [� 00 'o O 0 y N N N Q1 V1 N N enQ\ CT --01 a0 O W .-. 10 �. w V N : t fn N [� A N T r- .-. � p, T a o� rn :• � � � 0 Id � ;::s W W t: �q o o v . dwwa:.�C) J O O O O O O O Cl O O o O O O O f- 'a� 7 V 3 _ p_ (� 0 0 0 0 0 0 0 0 0 0 0 0 0 0 y.. 3 U) ` J Qco O U. m 'c U U U _> C a w 0 3 R R j T O R 3 R N +.+ U. m m n. lL J 00 Q, O a [� N M t� V CT -T N v� N M £ T y o c� M M a M N V' v� v� M '0 L R O — U m o rn oo � 0 0 o O o � 3 0/ 1A M M �A O t �O 00 l� O 00 O M v1 r- \ v� O v 7 M .r v1 �O G en 7 t CL [- l- l- �O 00 IO 00 l� 00 M NL lLI a ss ss sss ss u� c as aaGQaq m C¢Cqa paa U U U U U U U U U d �= O U 3 U R L d N N O O N � aNi r z z ^• •-• w w N N w w � '-• N w •--• •-• w V w w Q .. co CA pa vn cn En v, O .a v dU dU add dd ON 3_ o C c R1 U W v V_z 4 oa 4 v C7 a U) A A A O CA R :L 0 R a0.. 7 0 W N w CD4)�` � s c c U u U W U W 0" p J N U i Z J J E .. N F F a� ° a t> o a d 0 1 E R z a w a w d d O o d s c c c co w 3 F F t7 U I.i!» -1 2 E- X an d d d7 A A J J O O O O O O O O O O O O 0 0 0 () O O O O O O O O O O O O O O O y J ty J Q R V N (' r CO �n N 'Q O D, H v r O, 00 00 CD O O O J O M V 00 w C 7 N 00 O, 00 M O M 00 v1 M N N Oi cl 01 M d' r In In r r 'n --� O 00 m O w o R r a, V1 V1 a,M 10 In 0� '0 _O kn 00 M V) 10 N 'S b V N N N 00 DD � M J O O O O O 0 0 0 O O O O O O O J to p_ (7 00 O O O O O O O O O O O O O E J Q J R 2 dC G M O 00 N DD r D Q, M b ,r r 7 0 V 0T O m T V N l0 00 00 Vl M N r 7 r Ih M M R G Ol N M C N M D1 C 00 10 0 7 M O M In R vl 00 O O r 7 M lc .+ WA V1 00 �D lO of O 7 r r N l \D 00 w O O L a I r r r r 10 00 �D 00 00 � { i SS SS SS SSar SS a a F F pQ� A A U U 4 U 4 U u o U U U C O Uuau�]] U.5 d 5 d d U U" U m U f U u. U U a O � E R z w -� ;, z ra m w w CW7 C7 N J O Cl O O O O O O O O O O O O J I I N, Q J N Q U E E C7 n 0 b r n O O O f J N N N N h I/1 en M It V V1 of Op co h V1 In Vl Q\ eT N N kn In cn i R 7 �t 7 M M M M N N 0 y i N tV O tV N N W eb 0 O N N O O N N N N t- •� (a O0O OHO oaO .�•/ Cli a 4n I � CD a, v v v Ed 0 � I M O Q L LL 04 � O J O O 0 Cl C. O O O O O O O O O O F- •� U c y eU a, U a c9 o 0 0 0 0 o O CD0 0 0 0 0 0 II•• y o t 0 C y Qcn J mR 3 m ey ; t U LL C y c w LL m m a LL Q M O M M M a,O\ CDN N O O "r V' N � O e` O O O e` r �--� •-� OO W N N N N tT Q� •L �O M �O � � M M M M M M M .•-i .-- M M V 7 N N A _ •C � •F, W h O VI vl v1 ti .--. O a O� O O O O m OMO OMO OMO oMo •N•1 .�- W W �O �O :a i a 7 7 (D CD�i 00 m LL I M 7 7 7 't M t M W a a� N � aQaq aa(a� !aa m a Caq 2 r � U U U U U U U U I •L w L N N O O d �"� 7 N .--� N N x N a i%'i r1"i �-. .7.En N .c U U U a MI cn o t6 C7 3 0 a to � •y 3 l0 LL Y IL r- C y •` � l6 _ E 0. d N � -' et C a o 0 o d ca .a z x x O y£ rn Z a 4 — U L d o d d m c t c c c c O w 3 U U I- i) -i-1 2 1- X an d d W A A { E!; J O O O O O O O O O O O O O O O O O O O C. O O O O O O O O O O O O O O O i { { (� O O O C. O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O N J G J a V N E (� O O h h O O O O O Q O Q O M O O O O O M Q V' a a\ O 00 00 N N O O\ ON M M Vi J b "T Q\ Ol 'Q Q 00 00 Q Q M M \O 10 l- [- to — .rVl Q y •-� `7 Q b lD N N �O �O e? M .-i V, w M O O h M M Q Q e-i r1 M M O, O, (71 M M N N N en M to Q V M M N { { d 0 0 N N O O Q Q O to O v) O h O O O O O h V) h h O 00 00 N N O Q Q \0 'O in to 7 v . ^ o0 00 0 o m o0 Id M In oo m tl t w o0 0o to = en rl 00 00 Q <}' rl �--� h M M Q, a, O� T �O 10 00 to V) Q Q M J O O O O O O O O O O 000, O O O O O O O O O O O O O O O O O O O O O O i { i { p_ (7 O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O J Q J (6 N 2 dC O O O O Q Q h h O CD ena N GC O O rl .-+ O 00 00 O O O to O O O O v) 00 o0 "G �O M c\ C j b h h O O M M Q C' M M 10 10 M- 00 W O Cl N T to M M O O N N O O N N \L lO M M O O (n O O t` h O O o0 N N •-1 .-+ M M M M M H) M N N N R d C. O rl .-. O O b �o O C\ C. O1 O Wn Cl O O C. O to v1 Q Q C. h h Q Q O a a\ O, a\ Ol = N O O h \O In In h h h h O O 00 00 Q 7 - p d V) v) M M lD 00 00 �D lO M M O O o0 0o Q y h 0\ Oi Q Q .-1 M M N N 00 a0 i d In In en In Q Q '-1 --+ Q Q Q <} In fM�1 M ar Jlr a-' .79 4 ,9 ar ar 4 W W W W Gil W W W W Gil W W W W W W Gil Gil W W W W W c as aaa as aaa aaaaa� a as a as a a g m m w w w al al m al w al a ¢¢ Q ¢ U U U U U v U U U U U U U U U U U U U U U U U c 0 U aw a� a U U U UC) U v U U U w U U U U U U U A U U x a a N x x x x x x x Ln 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 i i i o o 0 0 0 0 0 0 0 0 o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (D0 0 fA J a J E Q Oi C1 'i 0) E (� O O O O M M O kn vl [- o [- b 'o CDO O O Q) C� 00 00 CD kn V) O 00 00 l- l� O b b C, C, J N .-. M en M M In V) 00 00 Cl O) V' V cl T M M 00 00 N t� h b b C^ C� N N I eY lV N M M kn V) Oi C\ f7 N 00 00 kn Vl In V1 In V1 1n V) -n V) kn vi -n V1 In V) Vn V) V) V) -n i i N s i 0) Vl O N N O [- [- O 00 O 00 C) C) O O O O M M 0 0 0 00 o0 O \C b M M O M M O M .-y .-a O\ O) N N b 10 O O M M O O b b O O 00 m V7 In C� cc L a oo M C� b e M M N N kn h M M C� D` to In 00 00 to In 00 m In Vi [l n v) In a Oi to Vi Iry n in n nN kn vi 00 m kn h Vi V1 kn In V to J O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O i t fA CL () O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O o O O J Q R M f.1 N C N O 7 V O t- [- O N O N N N O b b O 4n V) M M O N N O tn vl N N O M M O b G J > N b 00 a0 C O et V V V 00 00 C\ C) `7 V' C\ Cl N N 00 00 ti b b O\ Q\ N N It V N N M M to C) N..r oo 00 .--� In V1 In V) kn V1 %A V) w) V1 to V1 kn V1 In V) In V) In V) V) R l4C j N O T T O W ao O N O N M M O )A v1 O 00 00 'V' V O M M O ' N O 00 00 T C, N N b b C\ C, N N O, C1 b b O O l� 00 L i a M M N N M M n o0 M M C;, rn 1n V) oo ao W) V) n c ' to V) r W) V) 00 In V) M V) to V) 00 0o 1n V) vL n to V) to M i w W W W W W W W W W W W W W W W W W W W W W W a s a s a s a s a s a s a a s a s a a s a s 'i U U U U U U U U U U U U U U U v U U U U U U Q V a x a x a x Q m ro U U Q 0.1 W U U Q W W U w wu a u u U U U w w w w m w m ra w m w U U U U U U u U u U U U U U Q W U Q W U Q W U b 00 ti N N 7 er 7 b a b a b a d z ww �w w �w zwz w w zw w zwz �w �w J O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O J s (, O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O J a E IQ m U 'C d E (' to V1 O V '7 \d \O O o O O V V M M O O O O as 01 O M O M — (D V V O \o \O O 00 O J y M T cl Cl V ' M M o0 00 - .-. t- t- " Vl to V) V V t- t- 10 \O It o O tl V V M M V •-1 v) VI V1 kn Vl to Vn M M = i eV N d b b O 00 00 O \O \O w 00 M M O h Cr- ON O\ O O O O N O N O O O .-r O to O n I00 W 01 \O \O M M t- t- V V N N a0 00 b � N N O O O O V V' l0 t d V V) 00 00 try V 1A Vl tn Vl V V V) V1 M M ti -� to Vl M M \O \O \O \O N N �--1 to � M M M M M M M M M J Cl O O O O Cl Cl O O O Cl O O O O O O O O O O O O O Cl O O O O O O O O O J y E J O 0 0 0 O C. O 0 0 O O O O O O O O O O O O O O 0 0 0 0 0 0 O 0 0 O O Q J a U N E J \O O O O M M O h [� V 'ct N N O V O V t- t- O t- O t- V O V .--i O M M O N O E i+ to "" eel V V O^ cl O O v V O O M M o0 00 I-i .--i to v) v V V 7 .-i .-. \O \O \O \O \O •-1 .r V1 Vl •-1 ..-, 0\ Q\ to V1 O\ O\ N V (A V1 to Vl tri Vl try Vl M M - \O T b \O \O l0 \Ci \D V 7 b eq d \O O O O M M O N N o0 00 to V) O N O !` l, O N O N to O V1 ON a\ O to h O t- O i N 00 \0 b M M t- t- V -It -It 7 00 00 00 00 rl .� O\ D\ - --+ 00 00 t- W L 1 7 V1 0 00 0 to V1 to Vl to V1 7 7 to to O O M M O O eN .-� C� O� to kn M «l rl .� O O \O \o O� O\ to V1 to I O O b b O1 O\ D\ 1n i M M M M M M N N i N W W W W W W W W W W W W W W w W w o a w a s w m a s w a as a p a X a k a X a X a x a k W w a X W a ¢ ¢ w ¢ m ¢ 3 �a 3 �¢ 3 w ¢ 3 w ¢ 3 o� ¢ ca U U U U U U U U N U N U N U N U N U N U N U Y C V U\O ¢DD U Wtb U ¢ ¢ ¢ ¢ o0 W }� N N \O \O � %0 wa0 U U U U U U U U U U X U X X 0 Q W U a GO 00 N N C � N x r�i xi r�i `xV \w0 OxtO 0wt0 m E+ F H F F F F F z w w w w a a a a a a a a m a a aa. ate. J I O I O O O I O O O I O O O I O O O I O O O I O O O J : (� O O O O O O O O O O O O O O O O O O O y J C. J E Q 2 C1 � E (' 00 N y) O O M O �/1 r r 0 M O M M M O <D J N V O N N r r K '7 enM O C� O, O� O O oo W N s �O O O PI M r r N N 01 v1 00 00 O m O o0 C% o\ O M M as O ON R V' 00 00 O �c �o rl O O O a ti M M �o �o 10 10 00 w en � M ..1 O O O O O O O O O O O O O O O O O O O i J : 1 1 to 0. 0 O O O O O O O O O O O O O O O O O O O E J Q J R V N E E J N N --� V' 7 0 O O N N V1 O h r r K V o0 00 O .r lG to r O r o0 00 It M M O O O o� O O O o0 00 N N (n \o O O - M 10 N N 10 \o V V' M M _ R C 01 r CT D\ O o0 O oo M M O M O M o0 W O O O O m al r,:, r o 1 t M M -It b �o 00 M M en en s ss ss ss ss ss ss WjX Wj c X Wjx ��X aX 0 ,WjX 3 ¢ 3 3 U 3 U 3 a 3 Q 3 Q L CAU N U N N N U N U N 1_ Q � x uz X U w w w w w U U w L N iwG iwG w� w� w� w� in In J O O O O O O O O O O O O O O J i EPi !i O O O O O O O O O O O (D O O T a J N Q U •� EC 'a0+ G L) M M O M M O 7 7 0 00 00 O �O %C cc 00 kn W) kn W) as a to i d d U i cd V F`' o � •Y T i O 1 o ! a% o. o v v 00 00 o a m rn rn o v v rn 0� o rn rn 00 00 'o U @ R '7 N N Q� T a0 W Vl v1 aa v M vi In v v to In m M � O M O W l t: O J O O O O O O O O O O O O O O O � Q (D 7 Q 0 .2 N C V_ 7 r d v a O O O O O O O O O o O CDo CDy d d C U) 7 J Q J L m .. U O 07 m m y; s d 0 LL U N •+ E C O 7 7 l`9 i1lT1�� m m (L GI M M O 00 0o O b \0 O N U- IL J n n r n N C14 N O b 10 M M N N � to M O O .•-1 O� O� V � V7 .fir n V' vl tn vl L l0 N f6 O O V� v1 [� 3 c0 i i a M M M° V 7 00 00 vi Vi Il kn vn LL i `y Inm W a a i ar ar ar 4 aq ar ar ar 4 i 0 � w d u u u IL ' Q U U v u u = w L R •L N N O O 0 7) N V 0 0 O O ]y^ Q' W W > ? ZZ��� Cl CD 0 Q U x ax x� Cla: a c U 4)= o .- ° o x U c > m 6 3 C9 0 LL p LL m 0 0 0 c c E a d ao q x x x 4)a n-1-j a 1 E a aaa .^ a v d p 0 H 4) ? a O t c c c o M� z z 0 I- CO)-j � H x m A A a a a J I O I O O I O O O I O 0 0 J i O O O O O O O O O y J Q Q R V N (g O O� D� ti --� O N O N ,J y N N en en t� w oc oo e` r- - vi Vi v v %Z �o" m o c CD O O o m o 0_0 (AO R Cl V� V1 en t+l O O rl O O _ n' V) R V' en M IO \D � M J O O O O O Cl O O O J 0 N Q (' O 0 0 O O O O O O Q J R CN cC O 'D %D � Vl O V1 O V) G J y N N en M = W V %D �D - y V) R i L N a i vi Vi Di D; N N �o" �o M i i s s ss ss i 3 3 a v c 0 U 0 0 0 o 0 0 X � U U co 0 .r cc W en SFr SFr G m N 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Info Project Address Washington Tower Date 10/7/2013 Compliance 223 Andover Park E For Building Department Use forms do not Tukwilla WA require a pasusesword to Applicant Name: TresWest Engineers. Inc. Instructional and calculating cells Applicant Address: 2702 S.42 St., Tacoma WA are write- Applicant Phone: 253-472-3300 [Project Description New Building ❑ Addition ❑ Alteration ❑ Plans Included Lighting Compliar.>'e � ath Q Lighting Power Density Calculations Q Total Buildin Performance g (If Total Building Performance then only LGT-CHK is required.) Lighting Power Allowance Method Selection required to Q Building Area Method ©Space -By -Space Method enable LPA forms Interior Lighting System Description Briefly describe lighting system type and features. Additions and Change of Space Use (C101.4.3 & C101.4.4) ❑ Addition area or Change of Space Use area complies with all applicable provisions as stand alone project ❑ Addition area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions per C101.4.3 Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) [] 60% or more of luminaires in space replaced Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Retrofit and non -retrofit spaces shall be documented separately using multiple forms. ❑ Less than 60% of luminaires in space replaced Provide a separate Space -By -Space Method (LTG-INT-SPACE) Compliance Form for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage table. Lamp and/or ballast replacement within existing luminaires only— existing total interior building wattage not increased ❑ New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 ❑ New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. ❑ Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. ❑ No changes are being made to the interior lighting and space use not changed. 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Rm Boa 1— 9lN A Project Address Washington Tower Date 10/7/2013 ` Lighting Alterations, Renovations & Building Additions 0 Less than 60% 0 60% or more 0 Stand alone 0 Addition Notes: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing b/dg lighting to demonstrate compliance. Refer to C101.4.3. b. For retrofits and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall existing builidng, include all applicable existing Space Types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. if less than 60% of existing fixtures will be replaced, provide total existing lighting wattage (prior to retrofit in the spacz. ?rot.` ed in the Maximum Allowed Lighting table. For Building Department Use Maximum Allowed Lighting Wattage Location (plan room #) Space Type' Allowed Watts per ft2 Gross interior Area in ftZ Watts- Allowed (watts/ft2 x area) E3.01-E3.19 Conference/meeting/multipurpose 1.23 16884 20767 E3.01-E3.19 Corridor/transition 0.66 41842 27616 E3.01-E3.19 Electrical/mechanicaf 0.95 4410 4190 E3.01-E3.19 Lobby 0.90 1854 1669 E3.01-E3.19 Office - Enclosed 1. 11 1053 1169 E3.01-E3.19 Restroom 0.98 1598 1566 E3.01-E3.19 Stairway 0.69 10081 6956 E3.01-E3.19 Storage 0.63 8942 5633 E3.01-E3.19 Hotel: Dining area 0.82 1713 1405 E3.01-E3.19 Hotel: Guest rooms 1.11 61101 67822 E3.01-E3.19 Hotel: Hotel lobby 1 . 06 2654 2813 E3.01-E3.19 Retail: Safes area 1.68 826 1388 E3.01-E3.19 Gymnasium/fitness center: Fitness area 0.72 1523 1097 E1.10 Parking garage - Garage areas 0.19 88785 16869 Atrium*` Enter Height:. Existing Lighting Enter Exist. Wafts:' Retail Display Allowance from LTG-INT-DISPLAY Seiect /able G40b.5.1(1) category tram drop down menu. For atriums, indicate height. Allowed wattage for first 40 feet is 0.03 W/ft. hL, above 40 feet is 0.02 W/ft. ht. Proposed Lighting Wattage Area Allowed Watts Total 243266 160959 Location (plan #, room #) Fixture Description"' Number of Fixtures Watts/ Fixture Watts Proposed E3.01-E3.19 Fixture Type AN 62 61 3782 E3.01-E3.19 Fixture Type AP2 3 50 150 E3.01-E3.19 Fixture Type AP3 3 50 150 E3.01-E3.19 Fixture Type VP1 12 61 732 E3.01-E3.19 Fixture Type AP5 2 108 216 E3.01,E3.02 Fixture Type AW5 6 26 156 E3.01-E3.19 Fixture Type AW2 329 27 8883 E3.01-E3.19 Fixture Type AW3 4 61 244 E3.01-E3.19 Fixture Type AW4 29 36 1044 E3.01-E3.19 Fixture Type AR1 77 59 4543 E3.01-E3.19 Fixture Type AR2 26 59 1534 E3.01-E3.19 Fixture Type AR4 24 59 1416 E3.01-E3.19 Fixture Type AS1 18 61 1098 E3.01-E3.19 Fixture Type AS2 7 61 427 E3.01-E3.19 Fixture Type AS3 123 61 7503 E3.01-E3.19 Fixture Type AS4 51 61 3111 E3.01-E3.19 Fixture TypeAT1 12 89 1068 E3.01-E3.19 Fixture Type AR3 6 59 354 E3.01-E3.19 Fixture Type AT3 9 32 1 288 E3.01-E3.19 Fixture Type HP1 2 49 98 E3.01-E3.19 Fixture TypeHP2 1 49 49 E3.01-E3.19 Fixture Type HP3 5 110 550 E3.01-E3.19 Fixture Type HP4 8 110 880 E3.01-E3.19 Fixture Type HP5 3 110 330 E3.01-E3.19 Fixture Type HP6 1 48 48 E3.01-E3.19 Fixture Type HP8 15 61 915 E3.01-E3.19 Fixture Type HW1 26 32 832 E3.01-E3.19 Fixture Type HW2 117 32 3744 E3.01-E3.19 Fixture Type HW3 36 32 1152 E3.01-E3.19 Fixture Type HR2 286 59 16874 E3.01-E3.19 Fixture Type HR3 54 59 3186 E3.01-E3.19 Fixture Type HR4 39 6 59 59 2301 354 E3.01-E3.19 Fixture Type HR5 E3.01-E3.19 Fixture Type HR6 17 59 1003 E3.01-E3.19 Fixture Type HR7 57 59 3363 E3.01-E3.19 Fixture Type HSI 55 61 3355 E3.01-E3.19 Fixture Type HS2 12 46 552 E3.01-E3.19 Fixture Type HS3 3 61 183 E3.01-E3.19 Fixture Type HS4 4 61 244 E3.01-E3.19 Fixture Type HT1 63 49 3087 E3.01-E3.19 Fixture Type HT2 53 110 5830 E3.01-E3.19 Fixture Type XS1 101 1 101 E3.01-E3.19 Fixture Type XS2 13 5 65 E1.10 Fixture Type PS2 76 118 8968 E5.01 Fixture Type HA 186 75 13950 E5.01 Fixture Type HB 186 75 13950 E5.01 Fixture Type HC 186 75 13950 E3.01 Fixture Type HK3 9 89 801 E3.01 Fixture Type XS3 2 5 10 E3.19 Fixture Type XS1A 1 1 1 Retail Display Lighting from LTG-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watt 137425 rnciuoe existng to remain ugnung nxrures ano exempt ugnnng equipment per notes below. Notes: 1. Include ALL proposed lighting fixtures. 2. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 3. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. 4. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 5. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description 6. If #NA appears in Retail Display cells, information on LTG-INT-DISPLAY is incomplete. (Interior Lighting Power Allowance COMPLIES ' • • • • 7-rm • luo• . ivi M I MOT; 2012 Washington State Enerqy Code Compliance Forms for Commercial Buildings includino R2 & R3 over 3 stories and all R1 Ravi—ri i. '?nld Project Address Washington Tower Date 10/7/2013 Lighting Alterations, Renovations & Building Additions O Less than 60% O 60% or more O Stand alone O Addition Notes: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. b. For retrofits and building additions, provide Building Area types and gross interior areas in the Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall existing builidng, include all applicable existing Building Area types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 60% of existing fixtures will be reply ;ed, use LTG-INT-SPACE form. For Building Department Use Space -By -Space method selected. Use LTG-INT-SPACE form. Building Area* Location (plan #, room #, or ALL) Area Description nlowed — Watts per ft2 Uross Interior Area in ft2 Watts Allowed (watts/ft2 x area) Select Table C405.5.2(1) Building Area from drop down menu. Total Space -By -Space method selected. Use LTG-INT-SPACE form. Location (plan #, Number of Watts/ Watts Building Area* room #) Fixture Description'* Fixtures Fixture Proposed select I ante G4U5.6.Z(1) Building Area trom drop down menu. Include existing to remain lighting and exempt lighting equipment per notes below. Compliance by Building Area Building Area Warnings Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Total Notes: 1. Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between Building Area types is not allowed under the Building Area Method compliance path. 2. Proposed fixtures must be listed in the building area in which they occur. Include ALL proposed lighting fixtures. 3. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 4. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 5. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 6. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in Fixture description. 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 8 R3 over 3 stories and all R1 Revised Jan 2014 Project Info Project Address Washington Tower Date 10/7/2013 223 Andover Park E For Building Department Use Tukwilla WA Applicant Name: TresWest Engineers. Inc. Maximum Allowed Display Lighting Wattage Location (plan #, room #) Retail Display Area Type* owe Watts per ft2 ** ross Interior Area in ft2 a s owe (watts/ft2 x area) * Only retail sales areas that meet the requirements defined in Table C405.5.2(2) footnote A may be entered here. Select retail sales areas form drop down menu. ** Wattages per Table C405.5.2(2) footnote A. ++ Display light allowance per footnote A calculation. Proposed Display Lighting Wattage Area Area Watts Total Display Lighting Base Allowance ++ Total Display Allowance unry separarery conrrouea oispiay nxrures inaepenaent or general area ugnnng per i able G4ub.b. Z(Z) footnote A may be entered here. Location (plan #, Number of Watts/ Watts Display Area* room #) Fixture Description Fixtures I Fixture Proposed Select retail sales display area from drop down menu. Proposed Display Lighting Totals Total Proposed Watts Retail Retail Retail Retail Notes: 1. For proposed Display Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all display fixtures. 2012 Washington State Energy Code Compliance Forms for Commercial Buildinas including R2 & R3 over 3 stories anti Al R1 P ,i—A I. 7nl A Project Info Project Address: Washington Tower Date 10/7/2013 v 223 Andover Park E For Building Department Use Tukwilla WA' Applicant Name: TresWest Engineers. Inc. Applicant Addr: 2702 S.42 St., Tacoma WA Applicant Phone: 253-472-3300 Project Description Q New Building ❑ Addition ❑ Alteration ❑ Plans Included Lighting Zone As specified by jurisdiction. Zone selection required to enable LTG-EXT form O Zone 1 O Zone 2 Q Zone 3 QQ Zone 4 Compliance Option Q Lighting Power Density Calculations O Total Building Performance Building Grounds Applies to luminaires > 100 Watts 0 Efficacy> 60 lumens/W Controlled by motion sensor Exemption (list) Exterior Lighting Alterations ❑ No changes are being made to the existing exterior lighting New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable exterior lighting controls per C405.2.4 and commissioning per Tradable Maximum Allowed Lighting Wattage Base Site Allowance: 1300 Tradable Surfaces Surface Description Allowed atts per ft2 or per If p Area (ft ), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Uncovered Parking and drives Top level of parking garage 0.13 W/ft2 29109 3784 Uncovered Parking and drives Site 0.13 W/ft2 118545 15411 Main Entry Door Main Hotel Entrance 30W/LF door width 10 300 Total Allowed Tradable Watts: 19495 lydudUle 1 rupused Lighting vvaTCage (Use mfgrlisted maximum input wattage forluminaire.) Number of Watts/ Watts Tradable Surface Fixture Description Fixtures Fixture Proposed Uncovered Parking and drives Fixture Type PL3 3 85 255 Uncovered Parking and drives Fixture Type PL1 9 456 4104 Uncovered Parking and drives Fixture Type PL2 3 456 1368 Uncovered Parking and Fixture Type PG1 2 210 420 drives Uncovered Parking and drives Fixture Type PG2 2 210 420 Main Entry Door Fixture Type HR8 15 154 810 i orat proposed traoaDte watts may not exceed the sum or total allowed tradable Total Proposed Tradable Watts: 7377 watts plus the base site allowance. Any base site allowance not needed to make tradable watts comply can be applied to individual non -tradable categories. 1V on- t radable Maximum Allowed Lighting Wattage Base Site Allowance Remaining: 1300 Non -Tradable Surfaces Surface Description Allowed Watts per ft2 or per If p Area (ft), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Bldg. Fagade (by Perim) Hotel Exterior 5.0 W/lf 594 2970 Bldg. Fagade (by perim) Apartment Exterior 5.0 W/lf 365 1825 Bldg. Fagade (by Perim) Parking Garage Exterior 5.0 W/lf 730 3650 Non -tradable Proposed Lighting Wattage Non -Tradable Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Bldg. Fagade (by perim) Fixture Type PW1 14 86 1204 Bldg. Fagade (by Perim) Fixture Type PW2 15 86 1290 Bldg. Fagade (by Perim) Fixture Type PW3 7 86 602 Bldg. Fagade (by perim) Fixture Type PW4 58 26 1 1508 Non -tradable proposed watts may not exceed allowed watts for any individual Total excess Non -Tradable watts: 0 surface unless the total excess watts for all non -tradable surfaces are less than the remaining site allowance. Site Allowance Balance: 1300 Exterior Lighting COMPLIES WITH SITE ALLOWANCE 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address Washington Tower Date 10/7/2013 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformerrequirements in the Washington State Energy Code, Commercial Provisions. Applicability Location in Building Department (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes LIGHTING CONTROLS (Section C405.2) C405.2.1.1 Manual interior Indicate on plans the manual control type & locations served; Indicate of plans the 50% lighting load reduction method E3.01, E3.02,E3.19 Yes C405.2.1.2 lighting controls provided or identify exception taken Indicate lighting system automatic shut-off capability - identify lighting zone areas served on plans; Automatic time Indicate locations of uverridF --.%itches on plans and the areas NA C405.2.2.1 switch controls and override switching served, include area. sq. ft.; Indicate locations where automatic shutoff is provided by other methods (occupancy sensor, daylight controls, etc) Yes C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors E3.01, E3.02,E3.19 Daylight zones - Indicate vertical fenestration primary and secondary daylight Yes C405.2.2.3 Vertical fenestration zone areas on plans, include sq. ft.; E3.01, E3.02,E3.19 and skylights Indicate skylight daylight zone areas on plans, include sq. ft. Daylight zone Indicate on plans the locations served by daylight zone controls; E3.01, E3.02,E3.19 Yes C405.2.2.3.2 controls Indicate in plans the lighting load reduction (dimming) method - stepped or continuous dimming Yes C405.2.3 Specific application lighting controls - Indicate on plans the locations served by specific application E1.00 General lighting controls Indicate lighting control method for display and accent lighting, C405.2.3 - Display and accent and display case lighting; Indicate these fixtures are controlled independently from both xA Items 1&2 lighting general area lighting and other lighting applications within the same space C405.2.3 - Hotel/motel guest Provide a lighting control device at each guest room entry for all E5.01 Yes Item 3 rooms permanently installed fixtures in guest room; Indicated whether lighting control is manual or automatic NA C405.2.3 - Supplemental task Provide automatic shut-off vacancy controls for supplemental Item 4 lighting task lighting, including under -shelf or under -cabinet lighting Identify eligible non -visual applications and method of lighting NA C405.2.3 - Lighting for non- control; Indicate these fixtures are controlled independently from both Item 5 visual applications general area lighting and other lighting applications within the same space Indicate lighting control method for lighting equipment for sale C405.2.3 - Lighting equipment or demonstration; Indicate these fixtures are controlled independently from both NA Item 6 for sale or demonstration general area lighting and other lighting applications within the same space If egress lighting power density is greater than 0.05W/ft2, C405.2.3 - Means of egress indicate method of automatic shut-off during unoccupied NA Yes Item 7 lighting periods; Identify on plans the egress fixtures that function as both normal and emergency means of egress illumination E3.01, E3.02,E3.19 C405.10 Cooler and freezer Provide vacancy device or timer to turn off fixtures within 15 NA C405.11 lighting minutes of unoccupancy for cooler and freezer lighting fixtures with lamp efficacy less than 40 lumens per watt Yes C405.2.4 Exterior lighting Indicate on exterior lighting plans the automatic lighting control controls method and locations served E1.00 Exterior building Provide motion sensor controls for building grounds fixtures NA C405.6.1 grounds lighting rated at greater than 100 watts with lamp efficacy less than 60 controls lumens, or identify exception taken Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; E0.01 Provide written procedures for functional testing of all automatic Yes C408_3 Lighting system functional testing controls and describe the expected system response; E0.01 Identify in construction documents the party responsible for functional testing of automatic lighting controls E0.01 INTERIOR LIGHTING POWER & EFFICACY Sections C405.5, C405.10, C405.11 20 22 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address Washington Tower Date 10/7/2013 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformerrequirements in the Washington State Energy Code, Commercial Provisions. Applicability Location in Building Department (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes Provide fixture schedule with fixture types, lamps, ballasts, and rated watts per fixture; E0.02 C405.5.1 aces eligible for li hfin Identify spaces 9 9 9 Power exemption on plans Yes C405.5.1.1 C405.5.1.2 Total connected and in compliance forms; NA C405.5.1.3 interior lighting power Identify lighting equipment eligible for exemption in fixture C405.5.1.4 schedule and in compliance p liance forms; NA Indicate that exempt lighting equipment is in addition to general area lighting and is controlle. Independently NA Yes C405.4 Exit signs g Provide exit sign types and rated watts per fixture in fixture E3.01-E3.19 schedule (maximum 5 watts per fixture) C405.10 Cooler and freezer For lighting in walk-in coolers and freezers, and refrigerated NA C405.11 lighting warehouse coolers and freezers, provide rated lamp efficacy (in lumens per watt) in fixture schedule Lighting Power Calculation - Indicate compliance path taken Complete required compliance forms — proposed wattage per NA C405.5.2 Building Area Method building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans Complete required compliance forms — total proposed wattage Yes C405.5.2 Space -By -Space does not exceed maximum allowed wattage. Identify locations Method of space types on plans, including retail display areas as applicable EXTERIOR LIGHTING POWER 8r EFFICACY Section C405.6 Provide fixture schedule with fixture types, lamps, ballasts, and Total connected rated watts per fixture; E0.02 Identify exterior applications eligible for lighting power NA Yes C405.62 exterior lighting power exemption on plans and in compliance forms; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting NA NA Table C405.6.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ Exterior building For building grounds fixtures rated at greater than 100 watts, NA C405.6.1 grounds lighting provide rated lamp efficacy (in lumens per watt) in fixture schedule Exterior lighting Complete required compliance form — proposed wattage for YES C405.6.2 power calculations exterior lighting plus base site allowed does not exceed maximum allowed MOTORS & TRANSFORMERS (Sections C405.8, C405.9) NA C405.8 Electric Motors For motors not part of an HVAC system, provide electric motor schedule on electrical plans with hp, rpm, and rated efficiency YES C405.9 Transformers Provide distribution transformer schedule on electrical plans E7.01,E7.02 with transformer size and efficiency PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-0899 DATE: 10/15/15 PROJECT NAME: WASHINGTON PLACE - BUILDING SITE ADDRESS: 223 ANDOVER PARK E X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: �.o Af� '�Ar Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 10/20/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DUE DATE: 11/17/15 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: hqp://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. J/4f �- , Date: clan Check/Permit Number: � r©k ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: wl:t 5wl, k4 Project Address: Z2 3 4J6w-ems 77a4/� l Contact Person: 6KI C-71qVz--- Phone Number: Summary of Revision: RECEIVED CITY OF TUKWIL.-Jz FEB 1 6 2018 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of rev' ion c Received at the City of Tukwila Permit Center by: Entered in TRAKiT on W:Termit Center (BrendafformsTermit Center Documents (Word)\Revision Submittal Form.doc Revised: August 2015 City of Tukwila SUBMTTA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.Tukwi[aWA.Ro Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: l_ Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # if after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: tz)4> -Wl/✓w; 8/ ProjectAddress:ContactPerson: F/✓ G() kfi LF/f/ Phone Number: Summary of Revision: 2, d,,vk/nu�/c--�lTflds 0<5 7 a -/77V �✓✓K i� .5�57 r-nr wt/d «ly ix�n ycW� F � GtJ IRl RECEIVED CITY Of TUKWILA APR 01 2011 Sheet Number(s): "Cloud" or highlight all areas of revision including date Received at the City of Tukwila Permit Center by: [3--Eiitered in TRAKiT on` revision <--L PERMIT CENTER WAPermit CenteffemplatesTorms\Revision Submittal Fortndoc Revised: August 2015 E C COMPANY Page 1 of 3 Rome Inicio en Espanol Contact. Safety Washington State Department of Labor & industries E C COMPANY Search L&I A-Z Index Help YIp Secure I &I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson PO BOX 10286 PORTLAND, OR97296 Principals 503-224-3511 ADAMS, GEORGE HARRY SCROGGY, JOEL J JANIK, STEPHEN THOMAS, VICE PRESIDENT BOCK, JAMES ARTHUR, VICE PRESIDENT BUSINESS FILINGS INCORPORATED, AGENT GOLDSTONE-SCHULLER, LEAH, MEMBER TRAPP, STEVEN C, MEMBER SCHMITZ, STEVEN D, MEMBER BALL, ROBERT SPENCER, MEMBER DESHLER, WILLIAM K (End: 06/28/2010) KELLY, RAYMOND THEODORE (End: 06/28/2010) PRENTICE-HALL CORP, AGENT (End: 06/28/2010) Doing business as E C COMPANY WA UBI No. Business type 601 107 330 Corporation Governing persons MALERIN F HAW LEY ROBERT S BALL; STEPHEN T JANIK; WILLIAM K DESHLER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. .............................................................. Meets current requirements. License specialties GENERAL License no. ECCOM**148BA Effective — expiration 01/01/1986— 06/30/2016 Designated administrator BAKER, DON E Active. Meets current requirements. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601107330&LIC=ECCOM**148BA&SAW= 12/10/2015 CITY OF T ICIM-A Permit Center/Building Division 206 431-3670 • Department of Community Development Public Works Department • 6300 Southcenter Boulevard, Tukwila, WA 98188 2o6 433-0179 Telephone: (2o6) 431-367o FAX (2o6) 431-3665 Planning Division ..: 2o6 431-3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO: STATE OF WASHINGTON) ss. COUNTY OF KING ) states as follows: [please print name] i. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.ogo applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number II � , and will therefore not be performed by a registered contractor. )5.I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. Own4//O-wner's Agent* LAURIE A. WERLE NOTARY PUBLIC STATE OF WASHINGTON COMMISSION EXPIRES Signed and sworn to before me this s day f / J�CP���✓� /� , 20 MAY 29, 2018 N#fARk PUBLIC in and for the State of Washington Residing at 114117e'l County Name as commissioned: My commission expires: 51-,22 l d 18.27.000 Exemptions. The registration provisions of this chapter do not apply to: i. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.7o RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; io. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entitywho-holds'a'valid electricaTcontractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28'RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household applianee:or.other small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. " Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. / ­ . I , I � � NREC COMMISSIONING NOTES (LIGHTING) FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUTOFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE LIGHTING CONTROLS SHAH BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY, . TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. DRAWING NOTES SHALL REQUIRE COMMISSIONING IN ACCORDANCE WITH THIS PARAGRAPH. Perm-1-tNo. Imo, �_fflvl Plan ' I * 1. 1. I I `8 ' 3. ,.vlewaPProv.o,,Ifssuoj=toerro,,san .P,�­sion- Approval e, ,_'-onsiructiun documents does not Eulhoize the violation of any adopted code or ordinance. Rcce,pt of approved Field Copy and conditions is acknowiedged: By: Data: !_ --.I!- f-ity 0i TUFk_Vv-.C1 %.If BUILDING DIVISION REVISIONS - I No Changes shall b,.,% M�,de to thi? .scope I Of %vork 7withol.,t prior , � _^. p p,. o v,-: I 0 f * '- , ­�<v�r"'­a Guildin7 r"'Vlz:r�n I - .11 . . I I',.,-,- - V110�:_. �" . � :� -��:" �--; r7l" 1�1-�"1)!rr�'l j-, '! P!ail Cubm"ttal . . , -.---. i ABBREVIATIONS ABBRV_ - DESCRIPTION ABBRV DESCRIPTION ABBRV DESCRIPTION A, AMP AMPERE G, GND - GROUND � P13 " PUSHBUTTON ------- ACP ACCESSIBLE CARD PATH GC, G.C. GENERAL CONTRACTOR , - I PNL - PANEL, PANELBOARD ­­ ADA AMERICAN DISABILITY ACT GFCI ­11 GROUND FAULT CIRCUIT INTERRUPTER PRI PRIMARY --- AFC AVAILABLE FAULT CURRENT GFP GROUND FAULT PROTECTION PS POWER SUPPLY, PROJECTION AFF ABOVE FINISHED FLOOR HH HA . NDHOLE . - PSE PUGET SOUND ENERGY ATS AUTOMATIC TRANSFER SWITCH HTR HEATER, WALL HEATER PV PHOTOVOLTAIC - ­ .--,-.--.. AOR I-- ____..___.._. ­­1­1 �.- ­ __ ____ - - - AREA OF RESCUE - ­1 . IDF ___ ­ - ­­ . .-.--.. ------ - ­ I ­-_­ ­.- . - INTERMEDIATE DISTRIBUTION FRAME .-.-. . ­­ (R) - __.. _... __ __ REVISED.- � AL ALUMINUM LCP LIGHTING CONTROL CENTER RCPT - RECEPTACLE BKR BREAKER LTG LIGHTING REF REFERENCE, REFRIGERATOR C CONDUIT LTS LIGHTS SCCR SHORT-CIRCUIT CURRENT RATING CKT CIRCUIT LV LOW -VOLTAGE SEC SECONDARY CO CONDUIT AND PULL WIRE ONLY MB MAIN BREAKER SHT --- --- ­... ­.- - ­ ­ SHEET I _ - ­_ ­.. . ­ ­ .. ­ � ... ... ­­1 ... ­ ­­ - -_ . . _'. - ­ ­ .1 -_ - --­ . I Comm I ­ ­ I - - -_ � -1 ..--. ­ ­ - - _... _. -...-..- __ - � -_ - __ -, ___.. - MC, M.C. - -..-... -, - ----- __..____ -, - .. - � .-- MECHANICAL CONTRACTOR SPD SURGE PROTECTION DEVICE .1 .. ­_­ .1 T .. ... ­ � - . ­ .-....-.-.. - � ­ . . MDF I � - .. . ­.. ....- ... I . ... I MAIN DISTRIBUTION FRAME I ­ I -_ sow .­ ­ . -.1. ­ 1. ­111 SCOPE OF WORK ­ .1 CTRL . .... . . - .... ­ .1 - I . - I . CONTROL I . I - MDP ­­ I— 1-1 ­. .. . - -1 --- ­ .. MAIN DISTRIBUTION PANEL . ­ . ­ ­ ­ .. . - ­ ... _­ _ ­ .. CU . ­_­ __.­ ...... .. ­­ ....... ­­­ . _­ ... ­­ I I ........... � .... 1-1.1.1 COPPER _­ _.. . ...__ MECH 1. ­.. .. -- -- ------- 1. ­_ __._ . I—— ­1 --- ­ -_ __ . MECHANICAL I . - ­ SS .­.­ ......... . ­ - I ­­ I .. ... ­ ­­ _­ ­... � .. . ..... .--.-- 1. ­ STAINLESS STEEL � -------- ------- I ---- --- I __­­- DLZ ---- . --- ----- -- ­ -- --------------------------- - -- ___ ---------- ---....---.-....-..-.-.---.-..-..... .......... DAYLIGHT ZONE --------------------- - ........ 1. -.1 MH ----- ­­­­1 ....... ­ .. . .... � - - ---- ­ I ....... ----- -- I ­.-I.-I.- - ---- ------ ­ -- --- - ---- MANHOLE -------- ----------- ----- I . ........ SW ---- - ------ ----- ___1 - ------ - ­­ - - ----------------- -------- ; --------- - ­­ ......... I_— .... ­ .. _... SWITCH _ I .............. - - ... � .. . ... . ............ ­­ (E) - -------- ------------------- ­ _. - - ---- ---- --- ­­ ­ I.. ----------- ­___.__­ ------- . ........ ................ EXISTING MLO MAIN LUGS ONLY TEL --------- � .............. _ - ----------------------- -------,--,-- . TELEPHONE - . --- . ...... ­ . ... ..... ......... EC, E.C. ­ ------------- I ------------ - -------- � ----------- --- ---- - .. .. . ....... ... _.____---- ____.------- ----------- --------------- - ELECTRICAL CONTRACTOR ; .. _._..._._...II . ..... ---- - - MR - ---- - ---- - ---------- ---- --------- - ----------------- ----------------------- '__._______...___.. _... _ ... � ------ _ - MOTOR RATED SWITCH -------------- ­­.­­ - --- TC -------- ­ ------- -- -- --------- � ......... ­­_­ - - --­-----­- ----- ------ --- . ..... . - -------- - ------- --- -------------- TELECOMMUNICATION ­ ------- � - --- -------------------- EF � - -- ---- � ... ­ ............... I---- .------- - ------- ­ ----- � -------- _____._________­_­ --------- - --------------- ­ ........ EXHAUST FAN . . .... � -------- --- ------------------- (N) ----..-......---.--.---------.� ---------_-- ----------------------------- --- - ­1 ------------------------ I—— ....... . .. ...._ NEW ........ . I ... ­­ .................. THRU .1 ... . .... . ..... ---- ­--- _­ ------ - --- ­­ - - ----------- - -- ­­ .......... - ------- - - - ----------- - -------- ---. THROUGH ._____­___.... ____.._..._.. ELEC ­_ ­­ ------ - ..... . . I .­ _ .. . ... . .... . ­ .. ...... I ----- -. ­­ -------- ­ _ I ELECTRICAL --- I ....... ----- ­­­ -- ----------- N .1 ---------------- ---- .... . . ­ I ..... ..... ..._ NEUTRAL .__­­ ------ - ---- (TYP) - ..... TYPICAL . ... EM - - . ­ � ­­ � --- . I - _'_.._.._..._.___._._.__. _.. EMERGENCY I ­ I - _. NEC .. _" ._ __­_ I _­ - .­ ___ ­ �. ­­ -1 �. ­ � . NATIONAL ELECTRICAL CODE - ­ ­__ UNO _ - - ­ 1. ­­ ------ ..... .. � - I ­ . - . - . - ­ __... , -_ UNLESS NOTED OTHERWISE - - ­ ­ ­_ EQPT ­ � -.-.,-.---..- _­ � I - 1. ____ __­­ ....... . ............. � ... ­ EQUIPMENT _­ � - _.' - 0C I __ ­ .­­ � - ­ I . ....... __ � __.. ­­ _­__.___ I -, � ON CENTER .. __--.--..-.�.-.-.--..-,--.-�.----..--�--.- W _ - -"--- WIRE _ _ . . ­ ---. - -, ­ - - ­ . (F) F _­ �- .- ­­ ­__.__.._..__. _.1._.._.­.­__.____.. .--- __.__.._ FUTURE _____'______ � OFCI ___ _____.___'_..____ _'_ _ . . ....... ...... ,. __ - - - ----- --..- . , - OWNER -FURNISHED, CONTRACTOR-INSTALLEDWP ------------- .---..--------- -.-...-.--..--,....... ---. -_ ­1 - ---- __ � - WH _--- -- .__..__­_­_.. ______ - - __.. _.- . ..... __ ... ...... ....... WATER HEATER, EATER, WALL HEATER _.­_.__­____­ ....______ _­ WEATHERPROOF --- '.__ .______­______­ -- ---- __.____._____.___. -----�--------..----------- FURNACE, FAHRENHEIT --------..---,- OFOI ---------,-- FA ---..---------------------------------------- ----- - ------ ----------------- FIRE ALARM -------..-,-- OWNER- FURNISHED, OWNER -INSTALLED XFMR TRANSFORMER _ -.-----------------.----.---.-.----.---� ---- --- ------------- - FAAP ____._____­_.____._ ----.-. OL __ -.---. -.---- --.--,---.----- - ---------- _ --.----------.---------------..-- ______' OVERLOAD --.--- - ---------- ____ -- ------ --.---..-,--------- ---.---- ______' - - ____ --------..- --- - --.------------ FIRE ALARM ANNUNCIATOR PANEL FACP ' FIRE ALARM CONTROL PANEL I I I P PHASE, POLE I I ELECTRICAL LEGEND � I DESCRIPTION SYMBOL DESCRIPTION . : I . 1. ­ . . : . . I I . GENERAL NOTES . I 1. ALL 12OV, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 1 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION -TYPE, INSTALLED TO PROVIDE, - PROTECTION OF THE BRANCH CIRCUITS. I . 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLEDDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER -RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 6.11 AND WAC- 296-46B.-406. . 1 4. ELECTRICAL INSTALLATIONS IN ADA UNITS SHALL COMPLY WITH AMERICANS WITH DISABILITIES ACT (ADA) STANDARDS FOR ACCESSIBLE DESIGN (CURRENT ADOPTED EDIT -ION). Lf_=� 6--' LIGHTING OR POWER PANEL . ---I FIEF - MECHANICAL EQUIPMENT CONNECTION -----------. ____ CONDUIT EXPOSED L -1i ______________._ -------------------------- ---- ------ CONDUIT CONCEALED IN WALL OR CEILING SPACE ONLY ---------------�-.----.-------------.-----.-�--�--.�---.-.---,-----..---.---.----�-------------------.-------- 6) SPECIAL EQUIP CONNECTION WITH LIQUID TIGHT FLEX TO MATCH EQUIPMENT - __ - - - __ - CONDUIT UNDER GROUND OR FLOORI . 0 . --------- EQUIPMENT CONNECTION --------- ---E- __ ----------------.--. EXISTING CONDUIT ---------------,----.------------------------------------------ 0 MOTOR CONNECTION ­-­­-­-_-------- 0 ---.-..-------.--------------------.-.-.-----------.---.---.----,------------.------- . ........ ---.-.-.,--------.----.----.-----------------.--...-...- CONDUIT UP -- - - -------------- --- . . ........ D . -,.,---.-.-.-..--...---------.-------.----.----------------.----...------. - ----- - - . . ........ � -- -- - ----------- - -------- � - - - --------- - --------- --------- -------- NON -FUSED DISCONNECT SWITCH � -_- ---- -- - --------- - ---- ­_ = a -----------------.--''-- - CONDUIT DOWN TCH - ------ - ------------ -.--,.- -1 _______­ -------- � - ------------------ - ----- - ------------- -- . ...... _____________________.__­ - - ----------------------- CONDUIT STUB OUT WITH PLASTIC BUSHING I --- a --- ------------------ - ---------- - - ----------- � ----- ------------- - --- - -------_---------------- - -------- � ---- ---------- - ------- - ---------------------- - - --- � - - ----------- - --- --- ------------ ----- � - ------- - -------- � COMBINATION FUSED DISCONNECT/MAGNETIC STARTER ---- ------- - � ................. I • --------- ---------- ----- -- --- ---------- ---------------- _____­_­_­______ - - --------- - ---- - ------ - ---------------------- ----------------- -- � .... ­___ _­ � --- - --- - _­­ - - __-- . I BRANCH CIRCUIT HOME RUN _ ­ ------------- ­_­ - --------- [P ------------- � - - ------------- � -------------- --- � ------ I ------- - ----------- - -------- ---------- -- � .......... ........ � --------- � ---------- ---- I ------ - - --------------- . ..... � --------- --- - _­_. � ------------- ­ MOTOR STARTER WITH OVERLOAD PROTECTION - - -- � - - ---- ------ ­________ 11 .-.-..-.-.--------..-....-----..---------------- -------- -----------------...---.--..-..� ------------ ------­­ ------------- - - ------------------ GROUNDING ELECTRODE PER CODES . - ,. -­­------______.____.' UR --------- - --------- ----------.-----.-.-------------.-.----.-.-.--..-.-.------------.� - - ------- - - --- - ----- ---------- ­­---------­----­--­ -- -- -- -------- - -- MOTOR -RATED SWITCH ----------- - FLEXIBLE CONDUIT . - - ---- 19 ----- ELECTRICAL CONTACTOR, TYPE AS INDICATED ....... ____­___.__.__ ---------------- - - - ---------..--�-,--------.-----.-....-.....---------.-------- - - ----- _______­.______.­.. - ----- � ........... - - --- - - LOW -VOLTAGE WIRING (0-10V AND CAT-5 FOR LIGHTING PLANS) . ----- -------.--.-.---...-..---...-....-.-.-,------.-..---.-.-.---.---------.---,-.--.---..-----�---.-.�------.----,--�..--,-----..----.-.--...� El SINGLE PUSH BUTTON __ --.----.--. - 0 __ __'________________.'_.___.___ -----------.._.------ ____--- ______ CODE SIZED JUNCTION BOX WITH COVER PLATE - ------------ � --------------- -,-..---------------------------- ------.--.-- PUSH BUTTON SWITCH TO MATCH EQUIPMENT STARTER AND CONTROLLER . . . � e RED EMERGENCY SHUT-OFF PUSH BUTTON ­ ­_ I - - - ___­ ... I - ­ ­ -.--.---- -- _ ----- ---- ____ ___ -.-- __ --.-..-..--- - -.- ....- _ .- - __________.____ --------- TYPICAL LIGHT FIXTURE DESIGNATIONS: _'____ _. __'_ Q& --- --- - _____'_ _'____ - - __ .. _ _. __ _ -..---- -_.- - COMBINATION FIRE/SMOKE DAMPER . nA0,_ N111 - -.----.-- - __ ___ _ - _ _ __.. __.. _'. 7a2 -'*- FIXTURE TYPE, SEE LIGHT FIXTURE SCHEDULE. 0 THERMOSTAT W/TIMER PER ENERGY CODE - DAYLIGHT ZONE NUMBER (REFER TO PLANS) _.__________­..._1 ___ _­___--- _'__­­__­_.. SWITCH LEG/ZONE ID . I POWER CIRCUIT NUMBER ____ = __ --- LIGHT FIXTURE, SEE SCHEDULE FOR TYPE ___ ---------------------- --- -.-.------------�---�-------� ELECTRICAL DEVICE AS INDICATED, A=ABOVE COUNTER ®EDUPLEX --- --- LIGHT FIXTURE, SHADING WITH SUBLETTER E INDICATES EMERGENCY PER - -_ -_ (a) - - RECEPTACLE EUL924 DEVICE - - - ------ ----* - -- _­. --------------.--..--------...-..-.-.-------...-----..-...-..---.-..----.--.-.-----...------------�--..-----------------.�-----.------.--.- 1:1 ---- --- -- - - - ------- - ---------- - - - ----------- LIGHT FIXTURE, SEE SCHEDULE FOR TYPE I& TWO DUPLEX RECEPTACLES IN COMMON BACK BOX AND UNDER COMMON PLATE _ --- -- - -.--------..-..--....-------.---------.------,----------------------------,-.- - ------ _____._______ 8 - - -..-------------.----.----.----------.-.-----.-..---------.,.-.--..-.--� - - ------_---_- - -- ------.-.------------,---..---..--- - ----- - - --- --------------- � DUPLEX RECEPTACLE GFCI TYPE -_ ------------------ _____ ____ x CEILING MOUNTED FAN/LIGHT FIXTURE (9) SPECIAL RECEPTACLE TYPE TO MATCH EQUIP SERVED, VERIFY REQUIREMENTS � � FLOORBOX WITH THE FOLLOWING CONDUITS: (1)1-1/4' UNDERFLOOR/SLAB . . ---,-.------------�-�---..-------..------,,----" - 0 TO ABOVE ACCESSIBLE CEILING FOR COMMUNICATIONS SYSTEM, AND (1) Q WALL MOUNTED LIGHT FIXTURE, SEE SCHEDULE FOR TYPE ------------------------. I 1- UNDER FLOOR/SLAB TO SUPPLYING PANELBOARD FOR POWER CIRCUITS 0 LIGHT FIXTURE, SEE SCHEDULE FOR TYPE LOW -VOLTAGE SYMBOLS BELOW ARE SHOWN IN PLANS AND DIAGRAMS t=� --.---.--..-----.---.----,-----.------. EMERGENCY LIGHT .- FOR .RACEWAY AND BOX PURPOSES ONLY. REFER TO LOW VOLTAGE . - SYSTEM PLANS, BY OTHERS, FOR COMPLETE REQUIREMENTS. ® EXIT LIGHT � V I TELECOMMUNICATIONS OUTLET, . SUBNUMBER=QUANTITY OF DROPS $ SINGLE POLE SWITCH TELEPHONE OUTLET i THREE WAY SWITCH I - TV OUTLET $LV' &VC LOW VOLTAGE SWITCH, LOW VOLTAGE COMBINE/1UNCOMBINE SWITCH ---------------------- -----.---..------..--........----.-.-..-..--,-..---.-----.-----..----------------- - ------ - -- ------.. - - T ANTENN A I MOMENTARY CONTACT SWITCH AREA IF RESCUE PILOT LIGHTED SWITCH �.-....-.------.--.---..----.-.....� isI ------------------ ---- ---��------.-------------------------------- ------.- ------ __.____._______� . INTERCOM SYSTEM t KEY ­ OPERATED SWITCH. . I I I I I ...-.-__--. - - ---------- ---.-..-,..---------.--------.----------- - I I - i .. MANUAL DIMMER SWITCH --,-"---- - - ___ ------,,------,--- -------,--,-- T -------..-.-..---.--..--..--...--.--.----.--.----------- WALL MOUNT OCCUPANCY SENSOR SWITCH . -------- --.-- ___._____.___________________. ____ 01,2 _ CEILING MOUNTED PHOTOCELL/DAYLIGHT SENSOR (#9 = DAYLIGHT ZONE #s) --,---------- ­_____._.___.' - - ------ -_ 6) LIGHTING CONTROL OCCUPANCY SENSOR DUAL TECHNOLOGY (WALL MOUNT) x ---- *-------------------,' - - ------- - ------------ _'­'_' - -------------------- --------- - - --- - --------------- - ------ __"'__'__"'_""'_"___ 9 LIGHTING CONTROL OCCUPANCY SENSOR ULTRASONIC (WALL MOUNT) ­ ---...------------.---.----.-.-.- _­________ __ 0 LIGHTING CONTROL OCCUPANCY SENSOR DUAL TECHNOLOGY (CEILING MOUNT) I .---------- --.-- -_ 0 LIGHTING CONTROL OCCUPANCY SENSOR ULTRASONIC (CEILING MOUNT) 0,0 LIGHTING CONTROL POWER PACK, LIGHTING CONTROL UL 924 TRANSFER DEVI RED LIGHTING CONTROL ROOM CONTROLLER WITH 0-10V DIMMING I LIGHTING CONTROL ROOM CONTROLLER WITH 0-10V DIMMING, AND INTEGRAL FR7CE .UL 924 TRANSFER DEVICE FOR EMERGENCY LIGHTING ; ( --- __- -__�' ' - _____�' , . I ___� . A XXXX-XX B XXXX_XX C I XXXX-XX D XXXX-XX E I XXXX-XX REF SHEET # RM RM # REF SHEET # I HOTEL ROOM BRANCH CIRCUIT SCHEDULE (REFER TO PLANS) I I . * . Ar%i I- 4,. . . , .,' ' . NFR k 70 - NL : ; : i I blit 03 2015 . . I � --i . Cfty :)-i TYPICAL APARTMENT UNIT SCHEDULE (REFER TO PI ANSI, ... n.f TUkvfl din nillic - --f RO-ISIA10 UNILI III It3 18IjAqflj.- 10 fi�410 ' - i . i � ' � '..7!t--1N - O.L V� 4 �' . ` � .1 7�N :7r1t4V' 1-"' � :4.._('� I � I ;i- I V , I I 11 " ..... _0 . , - . SHEET INDEX . SHEET# SHEET TITLE , � -EO.01 ..­------_ ..... EO.02 -_ EGEND AND SHEET INDEX .�. .......------------------­----------- ------- ----------- --------- - _ ---------- - ­ ....... I . ..... ...... ­ .­ _.... LIGHTING FIXTURE. SCHEDULE . __' *"--,- - * ------ - ----- -------- ---------- ____ -_ --'----------- . ____ --------,-*-- ___---- E S FOR MECHANICAL EQPT __---- ____..___­_­__­­ . .... .... ­ - I _. - - _­___ -.---.- ­._____.___ - ____ -.-.---.-- --------- ___' .-..-- ­ - - _­____­___ � __ � � ----- ELECTRICAL SITE PLAN ­ .. . ­ ­1 ­ .. ... ..... . . ... ...... .. . ------------------ - -----................ . - ...._­ .. ..... I., . . ... ... 11 ... ..... ­ - -..-- _­­ .......... ­ ­ � PARKING STRUCTURE ELECTRICAL ­........ ......... __...__­_..­ --- I _. -.-,-. - ... ___ .. ..... I—_ --- - ------------ ------- 1ST FLOOR ELECTRICAL PLAN - - ------- ---- - - � ---- --- __._.'___.____.___._.. - ------ --------- ------ -------------- - -------- - ------- - -------- ------ - ----- - - -.--. -, 2ND FLOOR ELECTRICAL PLAN---- ---.-..--- EO.03 ____ - ____... ------ ----.----.-- E1.00 ­___ ­1 ----- ­ ..... ..... . ............ ........ ­ E1.1 0 ------- - --- ­ ­­ ­­­­­ - ­ ­ ---- E2.01 ---------------_-- -- - -- ---------- - - ------------ _'_'______ E2.02 - E2.03 3RD FLOOR ELECTRICAL PLAN --.------- ­__ _________ . ---. E2.04 ...... -.1 --------- - --------------------------------- E2.05 ----------------- __ . 1- 1-1 --- ------ I—. ­ _ .... E2.06 ----------- -- � . ... ...... .... ..... __ -------------- E2.07 ----------- --------------------------- 4TH FLOOR ELECTRICAL PLAN ­­ ....... . ­ . ................ � .... . .. ..... ----------------------- ------------- --- ­­­ - ------------- --------- -- ­­ . . .................. .... I ------------- - -- - - --- ---------- - - . ---------- ---- ­_­ 5TH FLOOR ELECTRICAL PLAN � --- _­­.- ----- ---------- ­__ ........... ­­ ....... . ... ­_ .... .. ­__- ­_ --l-­­ - - -------- .... ...... ... _­ 6TH FLOOR ELECTRICAL PLAN ......... . ... _____ ------- - ----- - - --- ----- - - _ _ --.-- --.--- - - _ _ ---.-- --- � - ------- --- ­... ... I .... ... � . . ................... _ ....... ..... .... _­ ---------- ----- ­­ 7TH FLOOR ELECTRICAL PLAN ---.-----.------------------,-----,.----- ____ - __ E2.08 _.______._____________________ 8TH FLOOR PLAN--.-.--- _____ ______ - E2.09 - .. ­ - - ... .. ­ � 11 -------- � --- . E2.1 0 .............. ­__ -------- - ------- - _­ .......... E2.11 __...__.___. ..-,.--.-...---------,-----..-.--.-- E2.12 -----.--.-.--.----.-,--.------ , . -ELECTRICAL ----�.---------.------------.-------.--- 9TH FLOOR ELECTRICAL PLAN .. I - � _­ .1 ..... ­ - . ..... .. ... I— - --- ---- -­ . - ____ - . _ - - . 1. . - ­ . I—— 10TH FLOOR ELECTRICAL PLAN _­1 .......... � ------------ - - ..... _­ - --------- - ------------ ---- ----- -.--.----- - ---- ---------- __ . ........ . . � -------- --- --------------------------- ---------------- __ ___------------------ 11TH FLOOR ELECTRICAL PLAN --- ____... . ........... - - - ------ ______________ ------- --.--- - ---------- - - ---- ------------- - -- - - - ------------- - � -------------- --- _'___.___________________ 12TH FLOOR ELECTRICAL PLAN ------�l-----.-.-.---.--.----.--------,--.-----.--------...----.----.--..--. ___''___.._____.___.____. _ 13TH FLOOR ELECTRICAL PLAN --E2.13' __ E2.14: ­.­ ..... ­__.____­___­ ------ E2.15 ____.1 - - -- - ------- - - - --- - ---_-------- .---- E2.16 ----- ---- ------------ - -------------------------------- E2.17 E2.18 __. --,-------------------------------, 14TH FLOOR ELECTRICAL PLAN --- - ----- --.------.--.----.------...-----------.-------.. - ----- '___'.' ------- - ........ .......... ................ I --------- _.__________..___________._ 15TH FLOOR ELECTRICAL PLAN .-..-----------.--.-...---.-------- - - - ------- - - - - - -- - - -- - - --- - ----------------------------------------------------- - --­---------------- . --- -------- ­.________-_______._ 16TH FLOOR ELECTRICAL PLAN . ______._­­ --------- - ----------------------­----- - -- --- - ------- -.-.--.., ------ ------------------ ­ . .... . . ........... -- ----------- � ------ ------- ­ ---------------------- ---------- . . ......... .... ­ -1 ..... . ...... � .... 1 7TH ELECTRICAL PLAN ----------- - -FLOOR --- -.------- ___ ---I------ 18TH FLOOR ELECTRICAL PLAN - - - - ---------- ---.----------------.------.--.- ______._____ _.______-------------------- LOUNGE ELECTRICAL PLAN . ---.----- - _------- E2.19 - _ E2.20 - ------------------- - -------- --- ------ ------------- - _. E3.01 � ---- - ------- � ---_--- - ----------- - -- - --------- --- . - --- E3.02 _. - .----------------------,---------- ROOF ELECTRICAL PLAN . -------- - ----- - ---- --- � ...... .... .... . .......... � -------- � ... . ... . ........ ... . .__.______ ......... - -- ------ --------- � ---- - -------------- --------- ------------ -- _ _ ------- --- - ------- .... ­ ­_­_ 1ST FLOOR PLAN LIGHTING I -------- � ....... . .............. � - ------ --- - --------- � ------------- ------------- - - --------- - - - ---- - ------------- . ........ I ----- - ------- ­ ---- - - --------------- - ------------- --- -- -... ... � - ------ - -_--------------------- LIGHTING ----------- ___ ___ E3.03 ,.------------- 3RD FLOORPLANLIGHTING ___________ __ I . E3.04 .___________ 4TH FLOOR PLAN LIGHTING - ----- --------------- E3.05 ­ --- -- ------------ _ ---- . ..... __ ...... ---- ___ - E3.06 ­­ ... ............... � .... .... . ... ...... ........... E3.07 - ------- -----. ..'__ -.,- ____ _ E3.08 ___ ­_-- E3.09 - ­ E3.1 0 - --- _ --- E3.11 ------- ---- ------------ ­­... __ .. � .......... E3.12 ._.____._____­._______--------- ____________.__ E3.13 --- ______.____. ----------------- 5TH FLOOR PLAN LIGHTING ------------------- -------- ___._______ ------- _ ---------------- - ----------- _ ..... - - - ------ - ----------------- ---- - -------------- ----- ----- - _ _ --- ----- -- - -------- --- --- _ .. 6TH FLOOR PLAN LIGHTING ­ ... ­ . -1 .... . ------------ � .. .... ­­ ----- .... ---- . . ...... ­­­ -- ------- . ----------- - - - - 1­ .. ......... .------------------- ­­­_ _.­ - ­ ... ..... . ......... ... __­_ - ­1 -..-., 7TH FLOOR PLAN LIGHTING .-------------- __ ­ - I - ----------- --- ----...-..----.-.--..----- ,--.------.. -- __'_'_____. ----.-.-... . .... .. --.---- 8TH FLO-__O_R PLAN LIGHTING - ----- --_­- -_­ - ----­.­ _-_ .1 9TH FL-OOR PLAN LIGHTING -.-. ­ - - --- - ___ ­. _- ---- 10TH FLOOR PLAN LIGHTING - .............. ..... ...... _______­_­ ....... . .. . --- - - ......-----. .. .... ........... ­ ... 11TH FLOOR PLAN LIGHTING � ------ ­ - ------- I ... ...... ­____ ­­ --------- ­­ -- - ---- � - ---- --- ___---- _____---- ..._ . ......... I-- ------- ------ - - -- ­____ - - - ----- - --------------- - ----------- ­­_.___._.___ ------- ­­ 12TH FLOOR PLAN LIGHTING ,------.---...---.-----------.---.------...-..--..-.----------..-.,... ---------- __ 13TH FLOOR LIGHTING -------..-------- - - E3.14 __ -PLAN -.-----. 14TH FLOOR PLAN LIGHTING . _ E3.15 _.....- - - ----- __ ______ E3.16 E3.17 15TH FLOOR PLAN LIGHTING _.________'.____________ -------- _.__.______._ - - ------- _.___..___.__._____ . ..... ...... --.-- -------.--..- - - - -------- 16TH FLOOR PLAN LIGHTING -------.------.--- ------- --.-------..---.------.---.--.--.---....--.---'-----------.------- 17TH FLOOR PLAN LIGHTING - E3.18 18TH FLOOR PLAN LIGHTING - E3.19 LOUNGE PLAN LIGHTING . E4.01 STANDARD STUDIO WEST . -'---''---------------- __:_____.____-------- E4.02 -----'---------- STANDARD ____ - ,------.-- - E4.03 .________.._____._ STUDIO STANDARD- 2ND FLOOR E4.04 TWO BEDROOM CORNER E4.05 ONE BEDROOM GARDEN 3RD FLR E4.06 STUDIO WEST PLUS -_ __ E4.07 .-- ____ E4.08 _ _ - __._________________. TWO BEDROOM COURTYARD -.-,--------- ---------- ---.-...-----------------..-...-------,- STANDARD ONE BEDROOM LONG E4.09 STANDARD STUDIO E4.1 0 TWO BEDROOM DEN _ E4.11 ­________­_­____________ E4.12- .____.___­.__.___.__ I E4.1 a ONE BEDROOM SE CORNER -----,..-..-.....-.-,---.-----.--- --------------,-"-",,----,---,-,----, - --- - -- - ------ ----------- ­_ STANDARD STUDIO LONG . _____ --------------------.----------.-----.-..-..-..----------- ... ONE BEDROOM STANDARD NORTH __ _ I E4.14. ' ONE BEDROOM NE CORNER --- E4.15, ONE BEDROOM NW CORNER E4.16 .-------. E4.17 . . .... ___ . ....... ---.--------.-.-.-..---,-,-----------------.---.--------------.--- E4.18 ONE BEDROOM w- DEN . - ___._______________ - -------- --------.--.----------.-.------------,--.--. - - ------- . .. . .......... . .. - - - ----- ONE BEDROOM NORTH LONG ....... - - - - - ----------------------- ---------------------------- ONE BEDROOM LARGE 0 E4.19 THREE BEDROOM WEST E4.20 THREE BEDROOM DEN - :TYPE A . I E4.21 TWO BEDROOM DEN SMALL . _.__.______ . E4.22 - _ __.______.... E4.23 _ . _________ TWO BEDROOM DEN 18TH FLR ..---.-.----- ____.- ------- - - _ ---- - ---- - ------------ - _______._ THREE BEDROOM DEN NORTH . E4.24 ' THREE BEDROOM DEN E4.25 . ONE BEDROOM WEST I E5.01 HOTEL ROOM TYPICAL UNITS .__'_. __ ____ - E6.01 ------- 1ST-4TH FLOORS ENLARGED ELECTRICAL ROOM PLANS . - ----- -.-..-----.---- '---'----- - E6.02* .-.-.----------,- ' 5TH-8TH FLOORS ENLARGED- ELECTRICAL ROOM PLANS E6.03 ' 9THENLARGED ELECTRICAL ROOM PLANS - E6.04 I . 14TH-18TH FLOORES ENLARGED ELECTRICAL ROOM PLANS E7.01 ONE LINE DIAGRAM (LEVELS 1-8) - - E7.02 .- .- ONE LINE DIAGRAM (LEVELS 9-19) - E7.03 .APARTMENT LOAD CALC E7.04 ..' I I APARTMENT LOAD CALC . I E7.05- .BRANCH CIRCUIT RISER DIAGRAM I E7.06 APARTMENT LIGHTING RISER DIAGRAM ___ - E7.O7 - _. HOTEL LIGHTING RISER DIAGRAM.-___ ____________ E7.08 LOW VOLTAGE RISER DIAGRAM . E8.01 . ELECTRICAL PANEL SCHEDULES. - E8.02 , ELECTRICAL PANEL SCHEDULES E8.03 I I ELECTRICAL PANEL SCHEDULES �Mr_0_F_TUM1LA___ E8.01 - E8.04 I . I ELECTRICAL PANEL SCHEDULES ­­101CM-2015 E8.05 ELECTRICAL PANEL SCHEDULES -PERM1 E8.06' ELECTRICAL PANEL SCHEDULES I CEN MR E8.07- - ELECTRICAL PANEL,SCHEDULES - - __ - - . - ----. __ --- --- - --- , I I � � . / . I ISSUE A I Date I Description 10/07/15 . I � I � I ELECTRICAL PERMIT ' ISSUE . I , SCALE: CHECKED BY: CHL APPROVED BY: * DRAWN BY: JAB KEYPLAN I PHASE ELECTRICAL PERMIT PROJECT NUMBER . . GWA NO. . PROJECT . ry w 3: 0 w F_ V w < < d- 3� 0 w < > j 0 § 0 z Z) < F- z Ce) N _r N U) < 3: 1 CONSULTANT REGISTRATION - 9LAI - -w .1 I ; I I . I I I --- 1-1 .... ­­­­­ --- � --- - ­­ - � = .GROUP WEST� ARCHITECTS, INC., P.S. 1 3601 FREMONT AVE. N. SUITE 314 1 SEATTLE, WA 98103 � PHONE: (206) 8264447 . I .. FAX: (206) 8264W46 . . � I SHEET TITLE AND NUMBER = . LEGEND AND SHEET . . ­ INDEX I . . I - . I I ' - - EO.01 . I\I I I - , t � ( � I I I - - - - _ - - - � , - , - . i I I PG1 SIGN LIGHTING SITE UTOPIA LIGHTNG MFL1-M150 MH 210 OR APPROVED EQUAL 3 w J 0 w U Cn w ry X � F-00 Ln N O LIGHT FIXTURE SCHEDULE MANUFACTURER LAMP INPUT ISSUE A Date Description 10/07/15 i ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLANry PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA N0. PROJECT W o w Y W:5 O O3: V Q I=— M N T� N Ln Lu U CONSULTANT z v) w w 0 z _ w CD z ' w W 0 w Z' 3: =boo w �o�M NI--N N REGISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER LIGHTING FIXTURE SCHEDULE E0.02 . z v) w w 0 z _ w CD z ' w W 0 w Z' 3: =boo w �o�M NI--N N REGISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER LIGHTING FIXTURE SCHEDULE E0.02 . t�f - 3 w 0 w U V) r a 0 w 0 w 0 �o M .= 0 w Ln ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT MECH. UNIT NO. VOLTS/PHASE LOAD (ANT(/HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) FIRE/SMOKE/COMBINATION DAMPERS FSD-1 120/1 0.833 A 1.0 A - - 3/4" 2#12, #12G NOTE 9 - CLOSED CIRCUIT FLUID COOLERS CCFC-1 480/3 15&2 HP, 10KW 41.7 A 60 60 1" 3#4, #1 OG HP2-56,58,60 - 4 HYDRONIC PUMPS P-CDS-1 480/3 25 HIP 42.5A 60 50 1" 3#6,#1OG HM1-1,315 - 15 P-CDS-2 480/3 25 HP 42.5 A 60 50 1" 3#6, #1 OG HM1-7,9,11 - 15 GAS FIRED BOILERS B-1 120/1 9 A 11.3 A 30 15 3/4" 2#12, #12G HR1-2 - 5 B-2 120/1 9 A 11.3 A 30 15 3/4" 2#12, #12G HR1-4 - 5 WATER SOURCE HEAT PUMP UNITS WSHP-1-1 H 480/3 7 A 7.0 A NOTE 10 NOTE 10 3/4" 3#12, #12G HM1-18,20,22 1,060 10 WSHP-1-2H 480/3 14.9 A 14.9 A NOTE 10 NOTE 10 3/4" 3#12, #12G HM1-12,14,16 2,130 10 WSHP-I-3H 27711 5.6A 5.6A NOTE 10 NOTE 10 3/4" 2#12,#12G HM1-2 390 10 WSHP-I-4H 480/3 5.7 A 5.7 A NOTE 10 NOTE 10 3/4" 3#12, #12G HM1-44,46,48 645 10 WSHP-1-5H 480/3 11 A A 11.4 A NOTE 10 NOTE 10 3/4" 3#12, #12G HM1-38,40,42 1,190 10 WSHP-1-6H 480/3 5.7 A 5.7 A NOTE 10 NOTE 10 3/4" 3#12, #12G HM1-6,8,10 805 10 WSHP-1-7H 27711 9.9 A 9.9 A NOTE 10 NOTE 10 3/4" 2#12, #12G HMI-30 450 10 WSHP-1-8H 277/1 5.6 A 5.6 A NOTE 10 NOTE 10 3/4" 2#12, #12G HM1-32 350 10 WSHP-I-9H 480/3 7 A 7.0 A NOTE 10 NOTE 10 3/4" 3#12, #12G HM1-24,26,28 1,060 10 WSHP-1-lA 480/3 11.4 A 11.4 A NOTE 10 NOTE 10 3/4" 3#12, #12G AP1-2,4,6 1,425 10 WSHP-1-2A 480/3 11.4 A 11.4 A NOTE 10 NOTE 10 3/4" 3#12, #12G API-8,10,12 1425 10 WSHP-1-3A 480/3 11.4A 11.4A NOTE 10 NOTE 10 34' 3#12,#12G AP1-14,16,18 1,425 10 WSHP-1-4A 480/3 5.7A 5.7A NOTE 10 NOTE 10 3/4" 3#12,#12G AP1-20,22,24 630 10 WSHP-I-5A 277/1 9.9 A 9.9 A NOTE 10 NOTE 10 3/4" 2#12, #12G APIA 520 10 WSHP-1-6A 480/3 7A 7.0A NOTE 10 NOTE 10 3/4" 3#12,#12G AP1-26,28,30 1,190 10 WSHP-I-7A 277/1 9.9 A 9.9 A NOTE 10 NOTE 10 3/4" 2#12, #12G APl-32 630 10 WSHP-2-1H 480/3 10.1 A 10.1 A NOTE 10 NOTE 10 3/4" 3#12,#12G HP2-49,51,53 1,240 10 WSHP-2-2H 480/3 13.8 A 13.8 A NOTE 10 NOTE 10 3/4" 3#12, #12G HP2-43,45,47 1,830 10 WSHP-2-3H 480/3 13.8 A 13.8 A NOTE 10 NOTE 10 3/4" 3#12, #12G HP2-37,39,41 1,560 10 WSHP-2-4H 277/1 9.9 A 9.9 A NOTE 10 NOTE 10 34' 2#12, #12G HP2-25 570 10 WSHP-2-5H 480/3 8.9 A 8.9 A NOTE 10 NOTE 10 3/4" 3#12, #12G HP2-31,33,35 1,010 10 WSHP-2-6H 277/1 9.9 A 9.9 A NOTE 10 NOTE 10 3/4" 2#12, #12G HP2-19 650 10 WSHP-2-7H 27711 5.6 A 5.6 A NOTE 10 NOTE 10 314" 2#12, #12G HP2-29 280 10 WSHP-2-9H 277/1 9.9 A 9.9 A NOTE 10 NOTE 10 3/4" 2#12, #12G HP2-23 670 10 WSHP-2-10H 277/1 9.9 A 9.9 A NOTE 10 NOTE 10 3/4" 2#12, #12G HP2-27 620 10 WSHP-2-11 H 277/1 5.6 A 5.6 A NOTE 10 NOTE 10 3/4" 2#12, #12G HP2-21 620 10 WSHP-2-1A 277/1 5.6 A 5.6 A NOTE 10 NOTE 10 3/4" 2#12, #12G APl-36 280 10 WSHP-2-2A 277/1 9.9 A 9.9 A NOTE 10 NOTE 10 3/4" 2#12, #12G AP 1-38 500 10 WSHP-2-3A 27711 9.9 A 9.9 A NOTE 10 NOTE 10 3/4" 2#12, #12G API-40 430 10 WSHP-19-1 480/3 13.8 A 13.8 A NOTE 10 NOTE 10 3/4" 3#12, #12G AP19-8,10,12 1,720 10 WSHP-19-2 480/3 7 A 7.0 A NOTE 10 NOTE 10 34' 3#12, #12G AP19-14,16,18 1,030 10 WSHP-19-3 480/3 13.8 A 13.8 A NOTE 10 NOTE 10 3/4" 3#12, #12G AP19-2,4,6 1,550 10 WSHP-19-5 480/3 8.9 A 8.9 A NOTE 10 NOTE 10 3/4" 3#12, #12G AP19-24,26,28 740 10 WSHP-19-6 480/3 13.8 A 13.8 A NOTE 10 NOTE 10 3/4" 3#12, #12G AP 19-30,32,34 1,585 10 WSHP-19-7 480/3 11.4 A 11.4 A NOTE 10 NOTE 10 3/4" 3#12, #12G AP19-36,38,40 1340 10 WSHP-19-8 480/3 13.8 A 13.8 A NOTE 10 NOTE 10 3/4" 3#12, #12G AP19-42,44,46 1,585 10 WSHP-19-9 480/3 5.7 A 5.7 A NOTE 10 NOTE 10 3/4" 3#12, #12G AP19-48,50,52 690 10 UNIT HEATERS UH-1 277/1 7.9 A 9.8 A MR -SW - 3/4" 2#12, #12G HMI-54 700 6 UH-2A 277/1 11.5 A 14.4 A MR -SW - 3/4" 2#12, #12G AP1-5 700 6 UH-213 277/1 11.5 A 14.4 A MR -SW - 3/4" 2#12, #12G API-7 700 6 UH-3 277/1 15.1 A 18.8 A MR -SW - 3/4" 2#12, #12G AP1-9 700 6 UH-4 27711 11.5 A 14.4 A MR -SW - 3/4" 2#12, #12G AP19-19 700 6 UH-6 277/1 11.5 A 14.4 A MR -SW - 3/4" 2#12, #12G AP19-20 700 6 UH-7 27711 7.9 A 9.8 A MR -SW - 3/4" 2#12, #12G APl-11 700 6 UH-8 277/1 7.9 A 9.8 A MR -SW - 3/4" 2#12, #12G API-13 700 6 UH-9 277/1 11.5 A 14.4 A MR -SW - 3/4" 2#12, #12G AP1-15 700 6 UH-10A 277/1 15.1 A 18.8A MR -SW - 3/4" 2#12,#12G API-17 700 6 UH-1 OB 277/1 15.1 A 18.8 A MR -SW - 34' 2#12, #12G API-19 700 6 WATER HEATERS DWH-1 120/1 1.5KW/1.5 HP 31.3 A MR -SW - 3/4" 2#8, #1 OG HP19-39 - 6 DWH-2 120/1 1.5KW/1.5 HP 31.3 A MR -SW - 3/4" 2#8, #1 OG HP19-41 - 6 DWH-3 120/1 9.6 A 12.0 A MR -SW - 3/4" 2#12, #12G AR19-38 - 6 DWH-4 120/1 9.6 A 12.0 A MR -SW - 3/4" 2#12, #12G AR19-40 - 6 DWH-5 120/1 9.6 A 12.0 A MR -SW - 3/4" 2#12, #12G HRI-18 - 6 DWH-19-1 480/3 4.5 KW 6.8 A MR -SW - 3/4" 3#12, #12G AP19-55,57,59 - 6 DWHA 1-1 480/3 4.5 KW 6.8 A MR -SW - 3/4" 3#12, #12G HP10-55,57,59 - 6 DWH-11-2 480/3 4.5 KW 6.8 A MR -SW - 3/4" 3#12, #12G AP9-31,33,35 - 6 DWH-6-1 480/3 4.5 KW 6.8 A MR -SW - 3/4" 3#12, #12G HP6-55,57,59 - 6 DWH-6-2 480/3 4.5 KW 6.8 A MR -SW - 3/4" 3#12, #12G AP9-37,39,41 - 6 DOMESTIC HOT WATER RECIRCULATION PUMPS RCP-1 480/3 1-1/2 HP 3.8 A 30 6 3/4" 3#12, #12G HP10-49,51,53 - RCP-2 120/1 1/2 HP 12.3 A MR -SW - 3/4" 2#12, #12G HR6C-59 - 6 RCP-3 120/1 1/2 HP 12.3 A MR -SW - 3/4" 2#12, #12G HRI OC-59 - 6 f RCP-4 I 480/3 1-1/2 HP 3.8 A 30 6 3/4" 3#12, #12G AP19-49,51,53 - i RCP-5 120/1 1 HIP 20.0 A MR -SW - 3/4" 2#10, #10G AR19-42 - 6 RCP-6 120/1 1/2 HP 12.3 A MR -SW - 3/4" 2#12, #12G AR9-59 - 6 RCP-7 120/1 1/2 HP 12.3 A MR -SW - 3/4" 2#12, #12G AR9-57 - 6 RCP-8 120/1 1/6 HIP 5.5 A MR -SW - 3/4' 2#12, #12G HRl-20 - 6 DOMESTIC BOOSTER PUMPS DBS-1 T 480/3 15 HP 26.3 A 60 40 I" 3#8, #1 OG AX1-1,3,5 - 1,4 NOTES: 1.) VFD FURNISHED BYM.C., E.C. SHALL INSTALL. E.C. SHALL PROVIDE RACEWAY/CONDUCTORS, DISCONNECT AND MAKE ALL CONNECTIONS AS REQUIRED. 2.) MOTOR STARTER AND CONTROLS PROVIDED BY M.C., E.C. SHALL PROVIDE RACEWAY/CONDUCTORS, DISCONNECT AND MAKE ALL CONNECTIONS AS REQUIRED. 3.) PROVIDE DUCT SMOKE DETECTORS, RACEWAY(CABLING, AND FIRE ALARM CONNECTIONS AS REQUIRED. COORDINATE WITH M.C. 4.) PROVIDE WEATHERPROOF NEMA-3R DISCONNECT AND MOUNT ON UNIT. PROVIDE UNISTRUT MOUNTING HARDWARE AS REQUIRED. 5.) PROVIDE WEATHERPROOF NEMA-3R DISCONNECT AND LOCATE NEXT TO UNIT. PROVIDE UNISTRUT RACK AS REQUIRED. 6.) PROVIDE MOTOR -RATED SWITCH NEXT TO UNIT. 7.) PROVIDE SINGLE FEEDER (1-1/2"C, 3#I, #8G) TO 100A DISCONNECT WITH 100A FUSES. DISCONNECT SHALL SUPPPLY INDIVIDUAL FEEDERS TO EACH OF THREE SINGLE POINT OF CONNECTIONS AS REQUIRED PER MECHANICAL EQUIPMENT. PROVIDE DISTRIBUTION EQUIPMENT AS REQUIRED. 8.) MULTIPLE EXHAUST FANS SUPPLIED VIA SAME BRANCH CIRCUIT. 9.) REFER TO PLANS FOR CIRCUITING. 10.) DISCONNECTAND CONTROLS PROVIDED BYM.C., E.C. SHALL PROVIDE RACEWAY/CONDUCTORS, AND MAKE ALL CONNECTIONS AS REQUIRED. ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT MECH UNIT NO. VOLTSIPHASE LOAD (A/W/HP} MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES 17 FRAME (A) FUSE (A) DEHUMIDIFICATION UNIT 480/3 30 KW 47.5 A 60 50 1" 3#6, #10G HP2-55,57,59 3,100 2,3,4,7 DHU-1 (NOTE 7) 480/1 480/3 1.5 A 18 A 1.9 A 18.0 A 30 30 -. 3 25 -3/4" 3/4" 2#12, #12G 3#10, #1 OG HP2-55,57,59 HP2-55,57,59 - - 2,47 2,47 ENERGY RECOVERY VENTILATORS ERV-1 480/3 98 A 105.0 A 200 125 2" 4#3/0 AL, #6G HDB-8,10,12 26,000 1,3 ERV-2 480/3 32 A 34.0 A 60 40 3/4" 3#8, #1 OG AP19-13,15,17 10,250 1,3 PACKAGED ROOFTOP GAS/ELECTRIC AIR CONDITIONING UNITS RTU-1 480/3 8.5 A 8.5 A 30 10 3/4" 3#12, #12G AP19-1.3,5 1,600 2 RTU-2 480/3 8.5 A i 8.5 A 30 10 3/4" 3#12, #12G AP19-7,9,11 1,600 2 HP-1.0 480/3 31.6 31.6 A 60 40 3/4" 3#8, #8G A19-35,37,39 - 5 FC-1.1 11 FC-1.2 11 FC-1.3 I 11 FC-1.4 11 FC-1.5 11 FC-1.6 11 HP-2.0 480/3 31.6 31.6 A 60 40 3/4" 3#8, #8G A19-41,43,45 - 5 FC-2.1 11 FC-2.2 11 FC-2.3 11 FC-2.4 11 FC-2.5 11 FC-2.6 11 EXHAUSTFANS EF-V1 120/1 116 HP 5.5 A MR -SW - 3/4" 2#12, #12G HM1-50 1,200 6 EF-V2 120/1 1/6 HP 5.5 A MR -SW - 3/4" 2#12, #12G HMI-52 300 6 EF-V3 120/1 1/3 HP 9.0 A MR -SW - 3/4" 2#12, #12G AR1-4 1,400 6 EF-V4 120/1 1/6 HP 5.5 A MR -SW - 3/4" 2#12, #12G AR19-1 500 6 EF-V6 120/1 1/6 HP 5.5 A MR -SW - 34' 2#12, #12G AR19-2 600 6 EF-V7 120/1 116 HP 5.5 A MR -SW - 3/4" 2#12, #12G AR1-2 1,100 6 EF-V8 120/1 1/4 HP 7.3 A MR -SW - 3/4" 2#12, #12G AR1-6 1,850 6 EF-V9 120/1 1/6 HP 5.5 A MR -SW - 3/4" 2#12, #12G HR1-1 550 6 EF-V10 120/1 1/6 HP 5.5 A 30 6 3/4" 2#12, #12G AR19-4 350 5 EF-V11 120/1 1/6 HP 5.5 A MR -SW - 3/4" 2#12, #12G HR1-6 300 6,8 EF-V12 120/1 1/6 HP 5.5 A MR -SW - 3/4" 2#12, #12G HR1-6 300 6,8 EF-V13 120/1 116 HP 5.5 A MR -SW - 3/4" 2#12, #12G HR1-6 300 6,8 EF-V14 120/1 1/6 HP 5.5 A MR -SW - 3/4" 2#12, #12G HR1-6 300 6,8 EF-V15 120/1 116 HP 5.5 A 30 6 3/4" 2#12, #12G AR19-6 1440 5 PRESSURIZATION FANS PF-AE1 480/3 20 HP 33.8 A 60 40 3/4" 3#8, #1 OG AX19-2,4,6 30,000 3,5 PF-AE2 480/3 20 HP 33.8 A 60 40 3/4" 3#8, #1 OG AX19-8,10,12 30,000 3,5 PF-AE3 480/3 20 HP 33.8 A 60 40 3/4" 3#0, #10G AX19-14,16,18 30,000 3,3 PF-HE1 480/3 15 HIP 26.3A 30 30 3/4" 3#10,#10G AX19-1,3,5 23,000 3,5 PF-HE2 480/3 15 HP 26.3 A 30 30 3/4" 3#10, #1 OG AX19-7,9,11 23,000 3,5 PF-HE3 480/3 15 HP 26.3 A 30 30 3/4" 3#10, #IOG AX19-13,15,17 23,000 3,5 PF-S1 480/3 7.5 HP 13.8 A 30 20 3/4" 3#12, #12G AX19-20,22,24 9,700 3,5 PF-S2 480/3 7.5 HP 13.8 A 30 20 3/4" 3#12, #12G AX19-26,28,30 13,000 35 PF-S3 480/3 7.5 HP 13.8 A 30 20 314" 3#12, #12G AX19-32,34,36 9,700 3,5 PF-CD1 480/3 7.5 HP 13.8 A 30 20 3/4" 3#12, #12G AX5-1,3,5 7,900 3 PF-CD2 480/3 7.5 HP 13.8 A 30 20 3/4" 3#12, #12G AX5-7,9,11 7,900 3 PF-CD3 480/3 7.5 HP 13.8 A 30 20 3/4" 3#12, #12G AX5-13,15,17 7,900 3 PF-CD4 480/3 7.5 HP 13.8 A 30 20 3/4" 3#12, #12G AX7-1,3,5 7,900 3 PF-CD5 480/3 7.5 HP 13.8 A 30 20 3/4" 3#12, #12G AX7-7,9,11 7,900 3 PF-CD6 480/3 7.5 HP 13.8 A 30 20 3/4" 3#12, #12G AX7-13,15,17 7,900 3 PF-CD7 480/3 7.5 HP 13.8 A 30 20 3/4" 3#12, #12G AX7-19,21,23 7,900 3 PF-CD8 480/3 7.5 HP 13.8 A 30 20 3/4" 3#12, #12G AX11-2,4,6 7,900 3 PF-CD9 480/3 7.5 HP 13.8 A 30 20 3/4" 3#12, #12G AX11-8,10,12 7,900 3 PF-CD10 480/3 3 HP 6.0 A 30 10 314" 3#12, #12G AX11-14,16,18 4,700 3 PF-CD11 480/3 3 HP 6.0 A 30 10 3/4" 3#12, #12G AX11-20,22,24 4,700 . 3 PF-CD12 480/3 3 HP 6.0 A 30 10 3/4" 3#12, #12G AX11-26,28,30 4,700 3 PF-CD13 480/3 3 HP 6.0 A 30 10 3/4" 3#12, #12G AX18-2,4,6 4,700 3 PF-CD14 480/3 3 HP 6.0 A 30 10 3/4" 3#12, #12G AX18-8,10,12 4,700 3 PF-CD15 480/3 3 HP 6.0 A 30 10 3/4" 3#12, #12G AX18-14,16,18 4,700 3 PF-CD16 480/3 3 HP 6.0 A 30 10 3/4" 3#12, #12G AX18-20,22,24 4,700 3 LOUVERS L-1 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G AR1-38 300 6 L-2 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G ARI-36 1,000 6 L-3 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G ARl-36 400 6 L-4 12011 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G ARl-38 1400 6 L-5 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G HP19-41 500 6 L-7 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G AR19-7 600 6 L-8 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G ARl-40 250 6 L-9 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G ARl-40 200 6 L-10 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G ARI-40 300 6 L-11 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G ARl-38 350 6 L-12 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G ARl-38 1100 6 L-13 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G ARl-38 1,850 6 L-14 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 7900 3,6 L-15 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 7900 3,6 L-16 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 7900 3,6 L-17 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 7900 3,6 L-18 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 7900 3,6 L-19 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 7900 3,6 L-20 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 7900 3,6 L-21 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 7900 3,6 L-22 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 7900 3,6 L-23 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 4,700 3,6 L-24 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 4,700 1 3,6 L-25 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 4,700 3,6 L-26 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 4,700 3,6 L-27 120/1 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 4,700 3,6 L-28 12011 0.833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 4,700 3,6 L-29 120/1 .833 A 1.0 A MR -SW - 3/4" 2#12, #12G NOTE 9 4700 3,6 NOTES: 1.) VFD FURNISHED BY M.C., E.C. SHALL INSTALL. E.C. SHALL PROVIDE RACEWAY/CONDUCTORS, DISCONNECT AND MAKE ALL CONNECTIONS AS REQUIRED. 2.) MOTOR STARTER AND CONTROLS PROVIDED BY M.C., E.C. SHALL PROVIDE RACEWAY/CONDUCTORS, DISCONNECT AND MAKE ALL CONNECTIONS AS REQUIRED. 3.) PROVIDE DUCT SMOKE DETECTORS, RACEWAY(CABLING, AND FIRE ALARM CONNECTIONS AS REQUIRED. COORDINATE WITH M.C. 4.) PROVIDE WEATHERPROOF NEMA-3R DISCONNECT AND MOUNT ON UNIT. PROVIDE UNISTRUT MOUNTING HARDWARE AS REQUIRED_ 5.) PROVIDE WEATHERPROOF NEMA-3R DISCONNECT AND LOCATE NEXT TO UNIT. PROVIDE UNISTRUT RAC KAS REQUIRED. 6.) PROVIDE MOTOR -RATED SWITCH NEXT TO UNIT. 7.) PROVIDE SINGLE FEEDER (1-1/2"C, 3#1, #8G) TO 100A DISCONNECT WITH 100A FUSES. DISCONNECT SHALL SUPPPLY INDIVIDUAL FEEDERS TO EACH OF THREE SINGLE POINT OF CONNECTIONS AS REQUIRED PER MECHANICAL EQUIPMENT. PROVIDE DISTRIBUTION EQUIPMENTAS REQUIRED. 8.) MULTIPLE EXHAUST FANS SUPPLIED VIA SAME BRANCH CIRCUIT. 9.) REFER TO PLANS FOR CIRCUITING. 10.) DISCONNECT AND CONTROLS PROVIDED BY M.C., E.C. SHALL PROVIDE RACEWAY/CONDUCTORS, AND MAKE ALL CONNECTIONS AS REQUIRED. 11.) POWER SERVED FROM ROOFTOP MOUNTED HP UNIT. REVICWt0l FOR COMPLIANCE WITH NFPA 74 - NEC DEL 0 3 2015 City of.TuWla RUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER I ISSUE I d i Date Description SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ---- ------ i - -- - ELECTRICAL PERMIT PROJECT NUMBER � I i GWA NO. PROJECT ry W I o Y Q Q O LuQ � >J 0Y I � 0 Z = V F- ! i N ■� i N VJ i I I I CONSULTANT Lu j I WI Z Vr Z W F- cn W cn Lu W F- 0 w w Lu "� v~i p zm o au- F=�oo M9 D Nf7 0 to 4 1 r M V N F¢- N N REGISTRATION ..s ST ».._ �`:_ S10 AL v .I 7/1 S GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826-4446 F SHEET TITLE AND NUMBER ELECTRICAL SCHEDULES FOR MECHANICAL EQPT E0.03 LCP-A LIGHTING CONTROL PANEL - MASTER LOCATION: MAIN R EC RM (A PARTMENi) PANEL TYPE MAIN MOUNTING: SURFACE NOTES: RELAY # PANED CIRCUIT # LOAD LOCATION LOCAL OVERRIDE SWITCH CONTROLLED RELAY CONTROLLED (ONIOFF) VIA PHOTOCELL RELAY CONTROLLED (ON/OFF)DESCRIPTION VIA TIMECLOCK NOTES 1 AL1-10 SOUTH PARKING LOT NO NO YES 2 AL1-4 GARGAGE ACCESS LANE NO NO YES 3 AI-1-6 WEST PARKING LOT NO NO YES 4 AI-1-7 APARTMENT BUILDING EXTERIOR NO NO YES 5 AI-1-4 GARAGE ACCESS CANOPY NO YES YES 6 SPARE 7 SPARE 8 SPARE 9 SPARE 10 SPARE 11 SPARE 12 SPARE E1413 SPARE SPARE ; l �f .............................................. ................. i' f.y ................ ....... ...... 01 3. Q a PL1 LCP-H LIGHTING CONTROL PANEL - MASTER LOCATION: MAIN ELEC RM (HOTEL) PANEL TYPE MAIN MOUNTING: SURFACE NOTES: RELAY # PANED CIRCUIT # LOAD LOCATION LOCAL OVERRIDE SWITCH CONTROLLED RELAY CONTROLLED (ONIOFF) VIA PHOTOCELL RELAY CONTROLLED (ONIOFF) VIA TIMECLOCK DESCRIPTION NOTES 1 HL1-9 HOTEL ENTRANCE (BUILDING) NO NO YES 2 HL1-2 EAST PARKING LOT NO NO YES 3 HL1-11 HOTEL ENTRANCE (CANOPY) NO NO YES 4 HL1-15 POOL LIGHTING NO NI YES 5 HL1-10 16TH FLOOR BUILDING EXTERIOR NO NO YES PROGRAM TO MEET DARKSKY COMPLIANCE 6 HLI-12 16TH FLOOR BUILDING EXTERIOR NO NO YES PROGRAM TO MEET DARKSKY COMPLIANCE 7 HL1-6 HOTEL SIGN LIGHTING NO NO YES 8 9 SPARE 10 SPARE 11 SPARE 12 S PAR E 13 S PAR E 14 S PAR E ......-+...... ..... .. ................ ....... N ELECTRICAL SITE PLAN SCALE: 1/16" =V-0" PL1 PL1 I- — GENE L MOTES 1. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. 2. REFER TO SHEET E3.01 FOR CANOPY LIGHTING. FLAN MOTES O PROVIDE COMM MANHOLE. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH UTILITIES. O CONNECT TO EXISTING COMM MANHOLE. VERIFY EXACT LOCATION WITH UTILITIES. O ROUTE VIA LIGHTING CONTROL PANEL 'LCP' LOCATED IN THE MAIN ELECTRICAL ROOM. OEMPTY CONDUIT WITH PULL STRING TO LEVEL 1 CAN FOR VEHICLE GATE COMMUNICATION. O EMPTY CONDUIT WITH PULL STRING TO LEVEL 1 CAN FOR SIGN CONTROLS. O PROVIDE 1" CONDUIT AND CONTROL WIRING TO ALL ASSOCIATED A.T.S. REVIEWED FOR COMPLIANCE WITi NFPA 70 - NEC DEL 0 3 2015 ady of Tukwila BUILDING DIVISION' RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/16" =1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry ui 3: 0 w zN Q O w F— pY 0 QH z N N N VJ ISULTANT REGISTRATION 5 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER ELECTRICAL SITE PLAN GENERAL NOTES 1. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. FLAN NOTES 1O VERIFY EXACT LOCATION PRIOR TO ROUGH —IN. OZ MOUNT TRANSFORMER HIGH ON WALL ABOVE ELECTRICAL PANELS. 3� UNDERGROUND 1 1/2- C.O. FOR CAR CHARGER STATIONS TELECOM CABLE ROUTING. O4 1- C, W(2)#8 CU & (1)#10 CU GND. LIGHT FIXTURE MOTES 1. FIXTURE TYPE PS2: BEGHELLI, BS10OT5HO-4—HT-254W-277V n ENLARGED VIEW J 1i8'= 1•-0' G-J ;G-i} G-H G-G G-F G-E G-D G-C G-B G-A Y �.. Y ! j J , } ! I i I............... .... ...... ( G2 -- -- _ -.- - S I _ GP-1 j : I' WP E � � i � EwP DN GP-1 ...:::::.. ._:::::::':::.':. I ' I i QPS2 I RAMP UP ! PS2 AXG-3 i I I E E I E t E I! E I E E E ' f { f .f f I € 3 t AXG-3 .�� �,. W-...................._ ..... - --- --- G4;--= -.... i --- - -- - - - -- - - AS3.. . -- .. .. ...... ............... ................. .. ..... ................ ................ kk f I. I ... _....: r tAX IR 30 { t ( J j 3 j AXG-3 f GP-3 E E E- E E E E S3 I rWnnr uuvvry E ::::::::::::::::::::::::::::::::::::::::::::::::::::::::: :::::::::::::::::::::::::: ; .. I............ 'I .............._'` ; AXG-1 �"`' WP RAMP UP 1....... ..w::.: WP :: N WP UP I ENTER I I AS� - E WP............ i I ! I I ! I i GR-3o PS2 ! PS2 I E i WP X� I I ! ( X� p ; ! O PS2 ! PS2 E AXG 1 � a E E I , - -- -- �—� L— -- ---- — -- -- - .. - - _. - - _ - .. - - G6 , _._ - -- - - - - — -- - -- - - - - - -- -- - - -- - I E G6--....... . AXG 1 ..r GR-9 11 —6 8 G 5 7 G —2 4 �;R-11,3: G� , Z E� R.. I• H I: G I U Q 0I— i— E F x � y 1 o I° 'I Y ao W 33 W F 3' 1 I o r 'E } i I is t 1 4 GP 1 z I Q SEE EN LARGED LAR GE EW ►x t JJ IEE T U U I I y k �: ��Ty 7: I ![ is E E • i SHEET :: THIS SH :: F J J _ _ ._....... - 1..- - .. - - _::_. - -- ... - .... -- __...... - - _: .._.. G7 �,-�---- —, - — � 1 fTYPI ( G4 }-------- G7 j- -- Q U F- U w J W w U 7 cn z Y Q.' Q a a I 0 0 0 w fn I0 N O 00_'\ _uj O LEVEL 1 PARKING STRUCTURE 1/16• = 1'-0' G-J (G-1 ) G-H G-G G-F G-E m G-C G-B G-A ! ! (i LEVEL 3 PARKING STRUCTURE I I 3 1/16' = T-0• LEVEL 2 PARKING STRUCTURE 1/16' = T-W G-J ;G-1) G-H G-G G-F G-E G-D G-C G-B G-A RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/16" =V-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 0. W 3: aw Y z O W Q 03: 0 Y �F_ V Q F-- M N U) CONSULTANT EGISTRATION 5 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER PARKING STRUCTURE ELECTRICAL E1.10L G1 - -- G2'-- (G7;---- G4 }------ I J Q U U w J W w U Z) En Z Y a 0- N I 0 0 0 W to G-J i LEVEL 1 PARKING STRUCTURE 1/16' = V-0' (G-1) G-H G-G G-F G-E 1%1 f 1 1/ L V.V. I 1 If f G-D G-C G-B G-A f I I I I I I I I LEVEL 3 PARKING STRUCTURE GENERAL NOTES 1. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. FLAN NOTES O1 VERIFY EXACT LOCATION PRIOR TO ROUGH —IN. O2 MOUNT TRANSFORMER HIGH ON WALL ABOVE ELECTRICAL PANELS. O3 UNDERGROUND 1 1/2" C.O. FOR CAR CHARGER STATIONS TELECOM CABLE ROUTING. O 1" C, W(2)#8 CU & (1)#10 CU GND. LEVEL 2 PARKING STRUCTURE 1/16' =1'-0• G-J (G-I) G-H G-G G-F G-E G-D G-C G-B G-A LEVEL 4 PARKING STRUCTURE 1/16' =1'-0' REVIEWED FOR RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/16" =1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT {1 W 3: ow Y rY z 0- o wQ W� p _Ile V z Q F=-' M N N rr� VJ CONSULTANT REGISTRATION SIGNAL ��� 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826.4447 FAX: (206) 826.4446 SHEET TITLE AND NUMBER PARKING STRUCTURE ELECTRICAL E1.10 t 3 v Ld W 0 a Z Q J Of 0 0 J LL F- �Lo 00 ILq N _ O N � W ON M \ O M O \ :' 2 HKR-42 7 J 1 927] 1 9 � HKR SEC II HKR SEC IT HK1/ HKR-1,5,9 0HRK-43,45 HKR-1,5,9 K-25,29 I I 8 HKR-33,35,37,39 HKR-6,8 I 1 1 HRK-44,46,48 ( HRK-68,70 A33�35A37A�39 20/2P6 8 ' __j HKR-2,4 - 50 HRK-44,46,48` R 9 HKR-10,12 HKR-26,28,30,32 20/2P HKR-14,16 / 20/2P 26 28 HKR-18,20 30 20/2P 32 HKR-22,24 20/2P 25 li -T AR1-11 -A-R-1 25- - I 1 E6.01 UH EMERGENCY FIRE PROTECTIO TANK RM. _ 25 _ 25 102 WP 837 SF RISER ICI RISER ©STAIR 01 25 ST-101 249 SF DBS ARX1-15 UH 25 _ UH WP FIRE COMM. CTR. 1Q1 348 SF I I I I (TM) TJ) i I HRK-56,58,60 I HRK-34 HKR-36,38,40 HKR-39,41 30/2P. n KITCHEN EQUIPMENT PLAN 1 i4• = r-0° WP I L I L 5 wP 1 ! 5 j IC' CATV MAINTAINANCE 104 105 1IG 173 SF IG 5 186 SF 5 1 ELECTRICAL EF E6.01 10 AR —22 IG 3 5 389 SF '1�. IN _ r-7-\ BItCL STORAGE 274 SF PLAN NOTES O1 COORDINATE EXACT LOCATION WITH CASEWORK CONTRACTOR PRIOR TO ROUGH -IN. 2O EMPTY CONDUIT WITH PULL STRING TO LEVEL 1 CATV FOR APARTMENT ENTRY SYSTEM PANEL. O3 UP TO LEVEL 2 ABOVE. O POWER SUPPLY FOR LAUNDRY CHUTE INTERLOCK SYSTEM. COORDINATE LOCATION WITH ARCHITECT AND INTERLOCK SYSTEM CONTRACTOR. 5O POWER SUPPLY FOR TRASH CHUTE INTERLOCK SYSTEM. COORDINATE LOCATION WITH ARCHITECT AND INTERLOCK SYSTEM CONTRACTOR. O6 DEDICATED RECEPTACLE FOR AMR ANTENNA. SEE DRAWING E7.08 FOR MORE INFORMATION. 7O TYPE I HOOD WITH BUILT-IN PANEL FOR FIRE ALARM SHUT -DOWN, LIGHTING AND CONTROL SWITCH FOR FANS. O WALL MOUNT TRANSFORMER ABOVE ELECTRICAL PANEL. O EMERGENCY TELEPHONE, ROUTE 1" C TO ACCESSIBLE CEILING SPACE. I I I I i TI TH� (TG) TF TD.2 TB.9 TB.1 TA' I I 27 HY1-20,22124 --- - F HY1-26,28,30 HY1-14,16,18 HY1-2,4,6 HY1-32,34,36 HY1-8,10,12 F F 8 1 3 EF LAUNDRY / HK HY1-41 125 4 28 B cm 29 51 ; F 3 O 144 DHW 29 _ S AIR 003 RISER I B IC2 iC 11 HY1-3,5 Ell T 03 31 31 ! �/ HY1 I M_'f�EP RISER 8 STk R ,E BLDG. MAINT. 29 FM5 i 126 UH 31 1 ?7 - 1 49 SF 205 SF 28 P 27 WSHP 27 MEN 27 WSHP 3 - I WP � HALL I 23 296 SF HR1-27,29,31 I T- TR 16 _ # POOL EQUIP 7ESP: M RESTROOM 26 132 0 129 � 98 SF 47 S �As32�c EF KITCHEN DININI 124 123 829 SF 1700IF I I — �T1 P � 6 " — —� T2 4 6 �T FSD FSD W , 21 I POOL 1505 SF 25—W—_SHHPP HR1-26,28 fWSHP 14 8 8 i I 25 ' 14 P — — — — — — — — — — —+-- — — -- T4 ) 16 21 WOMENS 25 HR1-8 A 122 HR1-14,16 187 SF 22 22 nu i cC wr VESTIBULE � 120 119 211 1 231 24 -_- 24 108 SF W mow' vow 38 rl 3( v�1 3 EXERCISE 38 ROOM 134 732 SF I z AL "55 7 De 79, HR1-21,23,25 21 / HR1-22,24 21 HR1-15,17,19 `y MMA I -'+L 32 i, 40 FSD �e HR1-3,5,7 2 WSHP ® O ;ELECT �_ .01FSD 35 HR1-9,11,13 qn API-55,57,59 336 34 WSHH 32 HR1 90 SF 91 11 11 F 34 32,34,36 1 HR1-33 TRASH 480/3P 137 5 - - - - - - - AR1-42 - - - - - - - - - WSHP BUS DUCT 7 TAP BOX RISER RE .ELEV. FM HOTEL ELEV BUS DUCT WP L BBY OLE BD-2 AR1-23 AR1--21 RISER 9 E 0-A FM3 IFM4 ISER oo-B 2: 6 SF RISER 58 SF 11 IC IC3 TAIR 002 81-102 IGSTORiE RESTROOM RESTROOM — — — 114 115 � — — — — — 107317 _ _66 SF 68 SF 7 13 RISER AMR ROM ESK 11 13 I 13 WSSHP STORAGE wrl ICE 11 118 117 106 SF 135 SF 9 — — — — T6; 9 -- — L— — T6.1 T7 ` COFFEE ICI 116A 475 SF T7.9 � I 9 1 AR1-13,15 13 APT. LOBBY 112 i J WP _ .. _. ._ _ _._.. _._ .__ i 1118 SF GARAGE g L WSHP 13 1 17 vESTIBI ACCESSLANE 9 A 113 108 AR1-7,9 WSHP WSHP 15PT.OFFIC WSHP _ 5 1837 SF 111 BIKE STORAGE 3�a S� 1 I " 109 MAIL FtOONI 1 13 AR1-17,19 � 19 611 SF 110 ! 15 17 � 7 276 SF 9 9 13 15 19 I 1 REVIEWED Fut. COMPLIANCE WI'" -v - _ 15 T-NFPA 70 - NEC 13 15 17 19 19 DEC 0 3 2015 1 City ofTUlcHrila BUILDING DIVISION I I I RECEIVED CITY OF TUKWILA TE f� i TD i TC ; (TB TA.6 ! T OCT 15 2015 n 1 ST FLOOR ELECTRICAL PLAN ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ILL W 3: O w F Y z a� O w >g p Y t� V z::) z cM N N U) Q ;ULTANT �. U z cn w w w z o w U' z c" W w F— w I f!) U rn W 0 z 04 U =boo U) �QM Wpi p M F— o V M M csl N11 REGISTRATION e�g- 5 ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER 1 ST FLOOR ELECTRICAL PLAN E2.01 m 3 Ld 3 0 a z a J CL 0 J LL 0 z N N �o 0 N p .. N W In ' N O \ O \ d- O ' I i GENERAL NOTES 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF RISER CIRCUITS PLAN NOTES O DOWN TO LEVEL 1 BELOW. O POWER DISC FOR AV EQUIPMENT RACK. PROVIDE NEMA 14-50R RECEPTACLE. CONFERENCE 2 03 34 232 WSHP STAIR 003 2-7H I ST-203 i RISER I 26 32 i FM.5 i 100 SF 13 ........ ....... `22 HR2A-23,25 I HR2A-19,21 ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 2) I 'MEETING 02 I HR2A-13,ib 17 26 229 i 26 MECH VOLTS/PHASE LOAD MCA DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES WSHP 30 1194SF - - - UNIT NO. (ANV/HP) (A) FRAME (A) FUSE (A) MEN WOMEtvs1112_3 HJ 238 237 EXHAUST FANS 158 SF 206 SF EF-A2.1 22 EF-A2.2 8 _ 26 � 28 EF-A2.3 - ---- - -...._ . -.. _ -- ................-- ........... ....- - - -- - - - ............................ ................................................... .... ....... EF-A2.4 : RES OM - 12 EF-A2.5 I � 239C , NC E F-A2.6 55 SFCONFERENCE 121 02 8 EF-A2.7 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 I HR2A-26,28,30 EF-A2.8 22 - - 22s � EF-A2.9 wsHP 592 SF 10 2-4Hcm ' 24 I EF-A2.10 10 EF A2.11 WSHP 2-11 EF-A2.12 EMPLOYEE BREAK EF-A2.13 239E 24 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 24 290 SF A $ 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. - 20..Trl _. I E4.01 E4.03 E4.02 E4.02 E4.03 E4.03 E4.02 E4.02 E4.02 E4.03 E4.02 i I j I i •:. � `'• '' ti r� % ; rim ' 1 '~ /-, /-`� ;TM; r J ` t T, tTH; tTCsl /TF. �TE*i , iD, iTC) B : TA.s 1 2ND FLOOR ELECTRICAL PLAN T� T6.1 ........... ................................ I 0931 ROL cVIEWED FOF, COMPLIANCE WITt-, NFPA 70 - NEC - - - - -�- - DECO 3 2015 City of-TukWila DECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE © Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: p w Y D_ a W Q W J OpY V QH Z M N �■ N v, Q CONSULTANT REGISTRATION 5 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31, SEATTLE, WA 98103 PHONE: (206) 8264M7 FAX: (206) 8264446 SHEET TITLE AND NUMBER 2ND FLOOR ELECTRICAL PLAN E2.02 ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - HOTEL ROOMS (LEVEL 3) MECH LOAD MCA DISCONNECT VOLTS/PHASE CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) UNIT NO. (A/W/HP) (A) EXHAUST FANS EF-H3.1 E F-H3.2 EF-H3.3 E F-H3.4 ------_ ...... ------------....- E F-H3.5 ....................................... EF-H3.6 .._........ EF-H3.7 EF-H3.8 EF-H3.9 EF-H3.10 EF-H3.11 120/1 1 /20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 .....----._........._...._...... EF-H3.12 ............I ...................... _......... EF-H3.13 .--....---- EF-H3.14 EF-H3.15 EF-H3.16 EF-H3.17 EF-H3.18 __.....--.-----..--.---...... EF-H3.19 EF-H3.20 - EF-H3.21 SINGLE -PACKAGE VERTICAL HEAT PUMP UNITS SPVHP-3.1 SPVHP-3.2 SPVHP-3.3 SPVHP-3.4 SPVHP-3.5 SPVHP-3.6 SPVHP-3.7 _.._..._.-_.-_...... . SPVHP-3.8 ................. _ ._.._.._._.._ SPVHP-3.9 ------------....................... - SPVHP-3.10 277/1 3.4 KW 17.4 A MR -SW - - 2#12, #12G NOTE 1 400 2 ^SPVHP-3.11 SPVHP-3.12 SPVHP-3.13 SPVHP-3.14 SPVHP-3.15 ..... _....... __.................._._... SPVHP-3.16 SPVHP-3.17 SPVHP-3.18 SPVHP-3.19 SPVHP-3.20 ----1 SPVHP-3.21 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE NEXT TO MECHANICAL UNIT. ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 3) MECH UNIT NO. VOLTS/PHASE LOAD (A/W(HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUST FANS EF-All 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-A3.2 EF-A3.3 EF-A3.4 - EF-A3.5 -- EF-A3.6 - EF-A3.7 ..................................... EF-A3.8 EF-A3.9 EF-All0 EF-A3.11 EF-A3.12 .__............... EF-A3.13 EF........... ....................... EF-A3.15 EF-A3.16 EF-A3.17 EF-A3.18 EF-A3.19 EF-A3.20 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. RM I RM 304 E4.02 RM I RM 306 E4.02 GENERAL NOTES 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF RISER CIRCUITS RISER TD.2 TB.9 TB TA j i 1 1 STANDARD 312,H I KING EF � EF KI�1C3 STANDARD H3.5 H .15 w ST AN DA 1(: € _ 313H 302 SF 303 SF KING STANDARD :. ,� 45 EF . ISER H3.16 AT5 EF WT 1 ICING STANDARD T1 :. ,.., ::....................: # # ` ii ;...........,...._.:c ;. _. �: i., :.: •... : �,...., i . ... s , , :: ....... ....... : :: STANDARi� < a STANDARD :: <;:; ,�.�HAI=T ,s .:: :: BEDR0�3€��€ s ; ;: S ARD ST ; : BEDR00 1 :: s r :............::- i STU1Dt0�EST # ,I, I, TAND ,; AI�DARD i, I� TWi}BEDRO£)M :: j ::� :13 I x: 3 317 319 321 ( CORNER 301 3€13 :. 30 a s 3£i7 303 311 315 , r _....................... I.I ? 'si , .. 5 :# :: :: # # � .c � ... ..323Nl=hip► /�� - ;��(�` . 338 SF 309 SF , ; 548 SF : < (:,, 548 SF SF - 309I" 529 SF ;: 54z3 SF 309 SF 309 SF 548 SF t 5 7 F s: s , U LL O 3 2L ,I E # # 1 . <I 0 5 -lr i> I # # I t Y ...................................,.,....................s.5............................................................................:.:s...........................................................-:..........................................................:.:............................._:.. s i .:.:.....................................................................1..:.................................. ......................... ........................ ....... .......... .............................. ................. ...................... ................... .......... ............ ........ r................. ........... .......... ............... ... ...................... ...................... .............................. ....... .......... ............... ....... ......................... .................... .. ................... .............................. s: :: j S :... ... ,.�:. :.:iri. <::: <.:ar::.:.:.... . ..: ........: ..w:.r�v .... :..: .: .. .... :.... :.. ...�vv:: .::. vv�::: ...:::;. :.:...:::::.::.:::.: .v i .... ,vim«::«• , :l - :max::vim:•<� _: City Of'TUkWlla • BUILDING DIVISION RM RM 301 RM RM 303 RM RM 305 i RM RM 307 I RM RM 309 RM RM 311 I RM RM 313 ( RM RM 315 I RM RM 317 RM RM 319 I RM RM 321 RM RM 323 I E4.01 E4.09 E4.02 I E4.02 E4.09 E4.09 i E4.02 E4.02 E4.09 E4.09 E4.02 E4.04 i RECEIVED CITY OF TUKWILA iTM? TJ� l TI I (TH) (TG) (TF; tTE (TD! TC) ,TB; TA.6 (TA OCT i 5 Z015 3RD FLOOR ELECTRICAL PLAN PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB YPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT L.L.. w 3: 0 w a o Of W J p Y V Q IZ)- z c1r) CV CV ♦♦1 VJ CONSULTANT :GISTRATION SIGNAL �Y 7/15 GROUP WEST ARCHITECTS INC. P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: 206 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER 3RD FLOOR ELECTRICAL PLAN E2.03 r- a N 0 o.. N . W Lr) i N O o � O ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - HOTEL ROOMS (LEVEL 4) MECH VOLTS/PHASE LOAD MCA DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) UNIT NO. (A/W/HP) (A) EXHAUSTFANS EF-H4.1 EF-H4.2 ----- ............... ..........---- -- EF-H4.3 - - ------------...-........ EF-H4.4 - EF-H4.5 EF-H4.6 EF-H4.7 E F-H4.8 ........._..... _................. .......... EF-H4.9 ......................_...._..-........ EF-H4:1.0 120/1 1/20 HP 1.0 A MR -SW - - 2912, #12G NOTE 1 80 2 EF H4 11 ........ ......... E F-H4.12 E F-H4.13 EF-H4.14 ^E F-H4.15 _ EF-H4.16 EF-H4.17 EF-H4.18 EF-H4.19 -EF-H4.20........ SINGLE -PACKAGE VERTICAL HEAT PUMP UNITS SPVHP-4.1 SPVHP-4.2 .....................-............__._.. SPVHP-4.3 SPVHP-4.4 ............. .............. - SPVHP-4.5 -'SPVHP-4.6 SPVHP-4.7 SPVHP-4.8 SPVHP-4.9 SPVHP-4.10 277/1 3.4 KW 17.4 A MR -SW - - 2#12, #12G NOTE 1 400 2 SPVHP-4.11 SPVHP-4.12 SPVHP-4.13 SPVHP-4.14 SPVHP-4.15 SPVHP-4.16 SPVHP-4.17 SPVHP-4.18 SPVHP-4.19 SPVHP-4.20 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE NEXT TO MECHANICAL UNIT. ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 4) MECH VOLTS/PHASE LOAD MCA DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) UNIT NO. (A/W/HP) (A) EXHAUSTFANS EF-A4.1 EF-A4.2 EF-A4.3 EF-A4.4 EF-A4.5 EF-A4.6 ............................................ EF-A4.7 - EF-A4.8 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-A4.9 _ EF-A4.10 EF-A4.11 EF-A4.12 ....... -EF-A4.13........ ----------------------------------- -EF-A4.14 ..... EF-A4.15 EF-A4.16 EF-A4.17 EF A4.18 - EF A4.19 _ - -- _.... _.._.... _...... EF A4.20 EF-A4.21 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. GENERAL NOTES 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF RISER CIRCUITS RISER t H --• ` ............418RM .......................... 4233 11 _.._..._.._.. A':'. A �{ t H HP4-39 :. :........... 86 Fk11. EF H4.9 .... EF 41 2..) S PVH 4.10 6 : i I to.ui : I KING -: :................. RM 408 HP4 -29 STANDARD :....................................H € :KIN... 'AN D408H S HR4A-20 .............................A 307 SF PVH 4.4 EF EF .G ..................i .R..... .A... 1542 PVH 4.16 B HR4A-22 C HR4A-24 H4. RISER.': AT5 4.1 i E5.01 f.. `• i �: ,::: _...:.. <tNo PVH STANDARD EF I EF KING STANDARD i :..RM PVH 406 H HP4-27 I ::40cH A HR4A-14 .................................... 307 SF ­11 ............................. , 1843 B HR4A-16 i C HR4A-18om E5.01 .. RM .:- 404 H HP4-25 QUEEN QUEEN A HR4A-8 .€ US :: STANDARD B HR4A-10 ..................................... PVH ..........04H^......... 4.2 333 Sr EF EF 41 I..........07H...........I 3�r3 SF PVH 4.1 C HR4A-12 H4.2 E5.01 RM I RM 401 RM I RM 403 I RM RM 405 I RM RM 407 I RM RM 409 RM RM 411 I RM RM 413 I RM RM 415 I RM RM 417 RM RM 419 I RM RM 421 E4.01 E4.09 E4.02 E4.02 E4.09 E4.09 E4.02 E4.02 I E4.09 E4.09 E4.02 1 Ti ITN TGi TF iTE� TD) TC, TM) to AT6 Z-L-l. TB TA.6 TA 4TH FLOOR ELECTRICAL PLAN „a.= V-0. ,T1; -- ----T6.1 EVIEWED FU . COMPLIANCE WTI-: NFPA 70 - NEC DEC 0 3 2M City of -Tukwila BUILDING DIVISION DECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: O w Y Z 0- o �Q W J F- pY V Q F- z N N T� N VJ l CONSULTANT REGISTRATION /15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 8264A46 I SHEET TITLE AND NUMBER I 4TH FLOOR ELECTRICAL PLAN E2.04 4 3 W Ld 3. 0 IL Z a J IL w 0 0 J Li Lo Lo N 10 0 to .. 0 .. WLo 10 o04 o� ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - HOTEL ROOMS (LEVEL 5) MECH VOLTS/PHASE LOAD MCA DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) UNIT NO. (A/W/HP) (A) EXHAUST FANS EF-H5.1 -EF-H5.2 EF-H5.3 EF-H5.4-...... EF-H5.5 ..._....E - F-H5.6...... E F-H5.7 EF-H5.8 ............................................. EF-H5.9 -- -- -- ...............- EF-H5.10 EF-H5.11 ............................................. 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-H5.12 EF-H5.13 .............................................. EF-H5.14 EF-H5.15 EF-H5.16 ...............................----- ...... EF-H5.17 EF-H5.18 -EF-H5.19 E F-H5.20 EF-H5.21 SINGLE -PACKAGE VERTICAL HEAT PUMP UNITS SPVHP-5.1 ........................................... - SPVHP-5.2 SPVHP-5.3 ..............I............................. SPVHP-5.4 SPVHP-5.5 SPVHP-5.6 ...... _...... _._.......................... SPVHP-5.7 SPVHP-5.8 SPVHP-5_.9 - SPVHP-5.10 277/1 3.4 KW 17.4 A MR -SW - - 2#12, #12G NOTE 1 400 2 SPVHP-5.11 .......... -._... -....................... SPVHP-5.12 SPVHP-5.13 SPVHP-5.14 ------............. ...................... SPVHP-5.15 SPVHP-5.16 SPVHP-5.17 SPVHP-5.18 SPVHP-5.19 _........... SPVHP-5.20 SPVHP-5.21 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE NEXT TO MECHANICAL UNIT. ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 5) MECH UNIT NO. VOLTS/PHASE LOAD (AM/HP) MCA (A) DISCONNECT CONDUIT WERE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUST FANS EF A5.1 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-A5.2 EF-A5.3 EF-A5.4 EF-A5.5 EF-A5.6 EF-A5.7 EF A5.8 - EF-A5.9-- EF-A5.10 EF A5.11 _._...... _----................ --- EF-A5.12 EF-A5.13 -EF-A5.14 .......................................... - EF-A5.15 T EF-A5.16 E F-A5.17 --EF-A5.18 - EF-A5.19 EF-A5.20 EF A5.21 - NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. GENERAL NOTES 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF RISER CIRCUITS RISER TB.9 TBA TA i T6.1 ----------- I 1 ­-.1 ::: .; ; ;--f r; ............ £" t. . ....... t •s i£ t a. b : :.:.:.i `sl% EDFOR t s STANDARD ONE h STANDARD ONE STANDARD ONE < z STANDARD ONE I STANDARD ONE �� IEW £: :- I �1C �W;g�}�tA WITH LA .............. < ". � .. .. < _. BEDROOM- :: , .: T DIO • r ; ' ,� ... STUDIO uL� O .. .. .. .... .. :,t..,,,,,;,,,,,,, < , :::�»:,:,»3:m_.. F.7E R qq �� �f g�yy�^•��y g �-�-�y�p �•�y �•••��.•'yg, E I �.,,». ............."......_., , . ., � C.l .: L.�EDRVOi" •• r....................:� .u„».....rv. 1 1'YO I�EL3Ra,/bf3Y� + - + ,. .. ,. • :..:................ . • STUDIO ..,,u,,,,_,,,,,,�, .... ,:.r . • ..:..'.................:................ I3EDR001•vt ,. :: STUDIO r D P�1 : ......................................._............... > .....,. . < BEC}RG`G`M . ,;F,�,. , „:,.,,.w....,.,..,: , £ .. : > .: < , I✓3E I�00 ; ..,r,,,,r,,,,,,,,.n..r , ...................., .:: ._ STUDiO ; .; ;, µ..µ I STUDIO WEST t .I.. .I, It. , tl.: t £ t STANDARD <• ; N , .-.::......, , »:, ,, : ,<: «««<.;<.<; > LONG STANDARD STANDARD LONG = r CORNER A 7Q IVEt> , ; LONG LO a , ; STANDARD STANDARD s , LONG w,SHAFT » ..:. NFP ry1 :: ti 17 s �+� y iiJ 51 52 3 i I 5 I 5Z3 j Yt ft�� l 519 .. j(( 5 7 5 £ °.?�5 614 's% s s ::t s :, �� i SF 310 SF DEC 0 3 2015 �0 SF t£ 1 SF L0 SF 571 5F 309 SF 571 892 SF 571 SF 57 £ 551 SF 309 S - - T9 : : t i r,. t i• t I I I I£ ila f Tu kw CjjV 0 .t t t „ t ..:.,.,:.::..:... ......... ....:.:.:..:::..:..:..:..:....: .:......»., :.:."...:.:,.:.v...:::...::...::...:.:::..................................r::.,»::::.,.:..,:n::.:.,:.»:...:.::::.:................. ............. ,.:,,:.+.::..,,,::.,,:::. ; r , i t r.,».:::..::..:::................. ............ .,,,......:,...:....:::::..:: .......... ........... :::::......:.. k t r £ .. .... :.. .... ..... j, ,,..... .. t :s :: .: s i. �.::n:::vtt:n<:x: ...... .. ...........r• .................:..,. :...................................................................................... ... ..... .. ............. .... ........................ .............................. .................. .... ..... .......... ............. .... ...... ....... ..................:. �........ I RM RM 501 RM RM 503 I RM RM 505 RM RM 523 I RM RM 507 1 RM RM 509 RM RM 511 I RM RM 513 I RM RM 515 I RM RM 517 RM RM 519 I RM RM 521 I I 1 E4.01 E4.09 E4.08 E4.08 E4.09 E4.09 E4.08 E4.08 E4.09 E4.09 E4.08 E4.04 I RECEIVED CITY OF TUKWIL A ( TM ! TJ TI (TH (TG) { TF TE (TD) TC TA.6 TA , OCT 15 2015 `� n 5TH FLOOR ELECTRICAL PLAN PERMIT CENTER ISSUE 0 Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = V-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB EYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT LL W 3: O W Y IZ 3: wg O > pY V Q F- z N N N ♦Z VJ CONSULTANT REGISTRATION 15 GROUP WEST ARCHITECTS INC. P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SH EET TITLE AND NUMBER 5TH FLOOR ELECTRICAL PLAN E2.05 ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - HOTEL ROOMS (LEVEL 6) MECH UNIT NO. VOLTS/PHASE LOAD (A/W/HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUSTFANS EF-H6.1 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 E F-H6.2 EF-H6.3 EF-H6.4 EF-H6.5 E F-H6.6 EF-H6.7 EF-H6.8 EF-H6.9 EF-H6.10 EF-H6.11 EF-H6.12 EF-H6.13 EF-H6.14 E F-H6.15 EF-H6.16 EF-H6.17 EF-H6.18 EF-H6.19 E F-H6.20 SINGLE -PACKAGE VERTICAL HEAT PUMP UNITS SPVHP-6.1 277/1 3.4 KW 17.4 A MR -SW - - 2#12, #12G NOTE 1 400 2 SPVHP-6.2 SPVHP-6.3 SPVHP-6.4 SPVHP-6.5 SPVHP-6.6 SPVHP-6.7 SPVHP-6.8 SPVHP-6.9 SPVHP-6.10 SPVHP-6.11 SPVHP-6.12 SPVHP-6.13 SPVHP-6.14 SPVHP-6.15 SPVHP-6.16 SPVHP-6.17 SPVHP-6.18 SPVHP-6.19 SPVHP-6.20 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE NEXT TO MECHANICAL UNIT. ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 6) MECH UNIT NO. VOLTS/PHASE LOAD (AM/HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUST FANS EF-A6.1 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-A6.2 EF-A6.3 EF-A6.4 EF A6.5 E F-A6.6 EF A6.7 EF-A6.8 EF A6.9 EF-A6.10 EF-A6.11 EF-A6.12 EF-A6.13 EF-A6.14 EF-A6.15 EF-A6.16 EF-A6.17 EF-A6.18 EF-A6.19 EF-A6.20 EF-A6.21 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. RM I RM 602 RM I RM 604 RM I RM 606 RM I RM 608 RM I RM 610 RM I RM 612 E4.25 E4.02 E4.02 E4.09 E4.09 E4.02 I I I I ONE BEDROOM STANDARD ONE I STUDIO STUDIO STANDARD ONE WEST STANDARD ONE BEDROOM STANDARD STANDARD BEDROOM BEDROOM 602 604 606 608 610 612 484 SF STAIR 001 552 SF 547 SF 309 SF 309 SF 547 SF RISER SD1 I ! RISER - - -- - - EF _ EF EF EF EF . FIRE �J RM ICI RISER- - `-2TM RISER RISER ATJ ATH _ I EF EF AEF r EF EF EF EF 6.11 EF _ I STANDARD ONE STANDARD ONE STANDARD ONE STUDIO BEDROOM- BEDROOM- STUDIO STUDIO BEDROOM - STUDIO WEST STANDARD I LONG == -- LONG ! STANDARD STANDARD LONG w/SHAFT 601 603 605 607 609 611 613 338 SF 309 SF 571 SF 571 SF 310 SF 309 SF 551 SF I I I I I ! RM RM 601 RM RM 603 RM RM 605 RM RM 607 ! RM RM 9 RM9 611 RM RM E4.01 E4.09E4.08 .0E4.3 E4 ITMI � TI (TH) (TG) TF!' GENERAL NOTES 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF RISER CIRCUITS PLAN NOTES O1 LOCATION TO BE DETERMINED BY PLUMBING DESIGN. TD.2 9 TB 1 TA i I I I I KING NORTH w/ RM 623 RM 618 DEN KING NORTH H HP6-21 H HP6-39 A HR6A-55 ! 61 sH EF 623H A HR6A-50 VH 386 SF EF 289 SF PB HR6A-57 B HR6A-52 - RISE C HR6A-59 C HR6A-54 SDS - E5.01 E5.01 FSDRISER PVH I AT2 KING ! RM 621 STAIR 003 EF STANDARD P_VH H HP6-19 RISER ST 603 IC2 621 H �=_' A HR6A-49 306 SF B HR6A-51 RISER FM 5 C HR6A-53 E5.01 - - - - - - - - - - T2 I I RM 1 616 RM 619 H HP6-37 I KING STANDARD QUEEN QUEEN H HP6-17 A HR6A-44 ACCESSIBLE TUB A HR6A-43 B HR6A-46 616H 619H B HR6A-45 C HR6A-48 PVH 340 SF EF EF 338 SF PVH C HR6A-47 E5.01 ! ! E5.01 RM 614 -- RM 617 PVH KING EF EF PVH H HP6-15 H HP6-35 STANDARD QUEEN QUEEN A HR6A-38 614H 617H A HR6A-37 B HR6A-40 307 SF 338 SF B HR6A-39 C HR6A-42 C I HR6A-41 E5.01 RISER E5.01 AT3 �- - - - - - - --�- - -- T3 RM 612 KING RM 615 H HP6-33 STANDARD QUEEN QUEEN H HP6-13 A HR6A-32 612H I 615H A HR6A-31 B HR6A-34 FP-V-H-R 302 SF EF EF 335 SF PVH B HR6A-33 C HR6A-35 14 C HR6A-36 , �: E5.01 E5.01 I i RM 610 - RM 613 H HP6-31 PVH KING I STANDARD EF EF QUEEN QUEEN PVH H HP6-11 A HR6A-26 6.5 61 613H A HR6A-25 B HR6A-28 302 SF I 335 SF B HR6A-27 C HR6A-30 EC HR6A-29 E5.01- - - - - - r- - - - - - E5.01 -- - ; T4 CORRIDOR RM 608 600H RM 611 H HP6-29 KING 898 SF H HP6-9 A HR6A-20 STANDARD QUEEN QUEEN A HR6A-19 _ B HR6A-22 PVH 3008 F EF EF 338 SF PVH C HR6A-23 C HR6A-24 .4 RISER E5.01 AT5 E5.01 RM 606 KING RM 609 H HP6-27 PVH STANDARD EF EF QUEEN QUEEN PVH H HP6-7 A HR6A-14 606H A HR6A-13 609H B HR6A-16 307 SF 338 SF B HR6A-15 C HR6A-18 C HR6A-17 E5.01 ! E5.01 I - - - - - - - - - - - T5 RM 604 -� RM 607 H HP6-25 QUEEN QUEEN H HP6-5 A HR6A-8 QUEEN QUEEN TUB 607H A HR6A-7 B HR6A-10 PVH EF EF 335 SF PVH B HR6A-9 333 SF C HR6A-12 C HR6A-11 E5.01 E5.01 RM 602 QUEEN QUEEN RISER RM 605 H HP6-23 PVH 6o2H EF AT6 EF QUEEN QUEEN PVH A HR6A 1 A HR6A-2 333 SF 605H B HR6A-4 340 SF B HR6A-3 C HR6A-5 RISER C HR6A-6 RM I RM 618 LV2 E5.01 E5.01 E4.0-7 ;� -L - - - - - - - - - - - -- -- - T6 PF I - T6.1 TRASH_ RISER- 2 BEDROOM - - - 6000 SD3 COURTYARD 27 SF RISER RISER FSD EF TYPE A ATM RES EELV FM2 RISER RISERHOTEL ELEV RM 601 618 FC LOBBY FM3 BTC LOBBY H HP6-1 918 SF RISER IC STAIR 002 600A T qTp RIS , RISER 600B .RISER KING SUITE A HR6C-2 ELECT / CATV 236 SF ICI ST 602 FM4 145 SF AT8 601 H B HR6C-4 600E I ELECT. 0 HR6C-3 HR6A-56 555 SF C HR6C-6 RISER DATA 600D D HR6C-8 �r .2: (2 FT 600K 4 SFRISER E5.01 E6.02 STORAGE E6.02 EF - -ffc RISERs� ISER - - - - - EF - - - - - - T7.9 - - - - - .9 RISER CTC DTC ATF - - - - T8 - - HR6C-1 - - - - RISERQ r AMR I H.K RISER 1 RCP DWH 600c IGO HK1 RISER ITE 1 RISER - 1 154 SF HK2 7IG _._ EF r EF q F EFA FEE Lis cl STANDARD ONE STANDARD ONE BEDROOM- STUDIO STUDIO BEDROOM- TWO BEDROOM ! LONG STANDARD STANDARD ! LONG CORNER � iCVIE�ED ��'� 615 617 619 621 623 = COMPLIANCE V1ll I ,� NFPA 70 'NEC 571 SF 310 SF 309 SF 571 SF 892 SF - ! -DEG 03 2015 T9 I I I I I RM RM 615 RM RM 617 RM RM 619 RM I RM 621 RM RM 623 E4.08 E4.09 E4.09 E4.08 E4.04 TE (TD) TC �TB TA.6 6TH FLOOR ELECTRICAL PLAN 1/8" = T-0" Clty of I ukWl a f BUILDING DIVISION RECEIVED CITY OF TUKWILA TA , OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: O Lu Y a3: z ILu O >� p Y �� V Q H z M N T� N ♦♦1 VJ CONSULTANT REGISTRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER 6TH FLOOR ELECTRICAL PLAN E2.06 3 W 0 a Z Q J a W 0 0 J LL ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - HOTEL ROOMS (LEVEL 7) MECH LOAD MCA DISCONNECT VOLTS/PHASE CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) UNIT NO. (A/W/HP) (A) EXHAUST FANS EF-H7.1 �EF-H7.2 ................ --........................ EF-H7.3 .---....--------------------------- EF-H7.4 ^ EF-H7.5 W .............................................. EF-H7.6 .............................................. EF-H7.7 _..EF-H7.8 ............................................ E F-H7.9 ...... EF-H7.10 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-H7.11 -EF-H7.12 EF-H7.13 _.......... .... _...-..-....... EF-H7.14 ............................................. E F-H7.15 EF-H7.16 __.... EF-H7.17 _ EF-H7.18 E F-H7.19 E F-H7.20 EF-H7.21 SINGLE -PACKAGE VERTICAL HEAT PUMP UNITS SPVHP-7.1 SPVHP-7.2 ............................................ SPVHP-7.3 SPVHP-7.4 SPVHP-7.5 ..... -... --------___..__.__ SPVHP-7.6 SPVHP-7.7 -........._.....-----------.......-- SPVHP-7.8 SPVHP-7.9 SPVHP-7.10 ... -............... _..... --- ... _....... SPVHP-7.11 277/1 3A KW 17.4 A MR -SW - - 2#12, #12G NOTE 1 400 2 SPVHP-7.12 SPVHP-7.13 --............................. SPVHP-7.14 SPVHP-7.15 SPVHP-7.16 SPVHP-7.17 SPVHP-7.18 SPVHP-7.19 SPVHP-7.20 SPVHP-7.21 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE NEXT TO MECHANICAL UNIT. ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 7) MECH UNIT NO. VOLTS/PHASE LOAD (A/W/HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUST FANS EF-A7.1 _.........- EF-A7.2 -.. 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 E F-A7.3 EF-A7.4 - - EF-A7.5 EF-A7.6 - EF-A7.7 -- EF A7.8 -- EF-A7.9 EF A7.10 _ EF-A7.11 EF-A7.12 ~WEF-A7.13- EF-A7.14 EF-A7.15 EF-A7.16 EF-A7.17 E F-A7.18 EF-A7.19 EF A7.20 EF-A7.21 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. RM I RM 708 E4.09 RM I RM 712 E4.02 RISER RM I RM 701 RM RM 703 I RM RM 705 I RM RM 707 I RM RM 709 RM RM 711 ( RM RM 713 I RM RM 715 I RM RM 717 RM RM 719 I RM RM 721 E4.01 E4.09 E4.08 E4.08 E4.09 E4.09 E4.08 E4.08 E4.09 E4.09 E4.08 (TM1 TJ v TH, (TG) �TF (TE1 (TD (Tc, E4.04' ( TB TA.6 7TH FLOOR. ELECTRICAL PLAN 118• = r-0• T6.1 T$ NOW I NFPA 70 - N - �?9, UEU 0 3 2015 City of.Tukwila. BUILDING DIVISION RECEIVED CITY OF TUKWILA `TA) OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB ;EYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W a LU Y Z aa. � ° W o3: ❑ Y V Q F=-- z cM N T� N VJ CONSULTANT REGISTRATION 5 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 8264U6 SHEET TITLE AND NUMBER 7TH FLOOR ELECTRICAL PLAN E2.07 m 3 V W 0 IL Z IL of 0 0 00 N 1 0 _0 0 N W !2 1O o", o"" RM RM 802 E4.25 ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - HOTEL ROOMS (LEVEL 8) MECH LOAD MCA DISCONNECT VOLTS/PHASE CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) I FUSE (A) UNIT NO. (A/W/HP) (A) EXHAUST FANS EF-H8.1 - 'EF-H8.2 EF-H8.3 ............................................ EF-H8.4 ........-.............. ....... _..... _.... EF-H8.5 .........---.---.--....-.. EF-H8:6........ ... EF-H8.7 EF-H8.8 EF-H8.9..._..... ............... -... -_...... _............ EF-H8.10 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-H8.11- ................. ....................... _.... EF-H8.12 Y_ EF-H8.13 ......_....... I ............ I .... I........... EF-H8.14 --------....--......... -...... - EF-H8.15 E F-H8.16 ^ - EF-H8.17 EF-H8.18 EF-H8.19 - EF-H8.20 SINGLE -PACKAGE VERTICAL HEAT PUMP UNITS SPVHP-8.1 SPVHP-8.2 SPVHP-8.3 SPVHP-8.4 SPVHP-8.5 SPVHP-8.6 SPVHP-8.7... --.---------........ SPVHP-8.8 SPVHP-8.9 ....... ___._...-..__..- ..... _.. SPVHP-8.10 277/1 3.4 KW 17.4 A MR -SW - - 2#12, #12G NOTE 1 400 2 SPVHP-8.11 SPVHP-8.12 SPVHP-8.13 SPVHP-8.14 __.......-_-_------------ SPVHP-8.15 . SPVHP-8.16 SPVHP-8.17 SPVHP-8.18 SPVHP-8.19 SPVHP-8.20 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE NEXT TO MECHANICAL UNIT. ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 8) MECH UNIT NO. VOLTS/PHASE LOAD (A/W/HP) I MCA (A) I DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES I FRAME (A) FUSE (A) EXHAUST FANS EF-A8.1 - ...... EF-A8.2 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-A8.3 EF A8.4 EF-A8.5 EF-A8.6 ..... ---...-'----.--.. EF A8.7 EF A8.8 .....__..._...--............-......... EF-A8.9 EF A8.10 EF A8.11 -..... -... .-..... _._._.....--------- EF-A8.12 .........EF-A8.13 - EF-A8.14 EF-A8.15 EF A8.16 EF-A8.17 EF-A8.18 EF-A8.19 EFA8.20 EF A8.21 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. RM RM 808 E4.09 /__�, "--. 1-\ TD.2 TB.9 TBA � TA 1_1� - Y i I ; j : GENERAL NOTES 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF - . __- ... ;:. RISER CIRCUITS _ _ __ \J - ._ T1 1. RM RM 804 RM RM 806 RM RM 810 RM RM 812 RM RM 818 "'� 1 E5.01 £ ' E5.01 t;; t ,. ; ;< �:».n .w...,..-..��.. - -- : -- 6 .0 E . 0 E4.07 - E4.02 E4.02 E4 9 4 2 __........:.......................................,.»..,..» �... n...,.., :.»k:...,:.r.»...; » T :»»., ,..,»,.,.,:n ,,,,,,,, s . ................. .... z »::::.:::::::::.:....::.: >».. I I I I I ;I s _......___........._ PF ::: ;.._................_.. _._„ ; > KING SUITE s ;: »....».»,»».._...,»»..........:......................._ ,»+.. »_,...,",,..,...,.,...................................».,»»...»..,..»..»......t.,....................................,..,,_.":,.,»,.,,:,,.+,.,.,..»...<:..................................,...,..,.."_,,.,. ,......» ................ »»... .. ............. .. k, , . »» ,, » ..w.:. 1.CD 6 . ..;... . : it .. ... ' • - - -- -_ --'--- z $ -- '-----.. ._.................................... . _ ._ ...--- , . , ...,s 8tJ £ s z Ts.1 s, " » 1, .».... S , , .:t ;. :. „.:t I �/ > ., k s ....... ....... s... , .. ,. (^ .... . <. 554 Si- -ii S. S ii: .t ... ...''f " r: r t r :. t, .. .. S',: r .. ;, ';:# ' " .. .;., .. , .... TRASH / ..: - R IS R PVH E iil I ;;#l#i- - - - - , :; #: ,. :< - - Y ,; :� - - - -- - __ - - - - - - - - - - _ _ .. -- ..........._.....:..: n �,.,- , EO€O<a-: .. . M ' T7 .. t. :: .20 #: &0 C ::. 1-- :, .. 0 w ...... . _....._........... _...M.__-..._....._ _. », ;: SD3 ;:: T N :; ;; : ; TUDI uTANCAI D 00€ E »..:, S A DARL� ONE ST DI S O ; >it :.... ........ .......... S TANiDARD ONE U O ,:a:.n,;....... ' : ...::....::..._,n,. ..»......::..:::.:r C©UITAD :. I.: ;;":.. I N 00 I _:» .. i OEBER M l » :; F . TAldDARI # ; BEC3ROOM ># # 27a _ FSD »„.:..':: EF' WEST ; .. BEL�ROOt�1 13EDIRC�OA�# , , STANDARI3 S 5ER : # s F .._.... . T `PE A R »».: V n. s .. ;: ::. .. , .< :>; �, •. HOTEL ELE � : , .. : , ISER .RES R.till 01.1­11RM 801 . . c� £301 ;............... 808 z31 ,.....,.....: # 812 t ;; .1 . .: I. ' , r :: 80 t.; LOBIB I 818 ;; . " RISER 8tJ2 _ - FC RISE »,,. , I. ..................................................................... t . #: " �E3BIBY H HP8 1 r . 1, , ,: ....r »:. ».. # # ».»», , tft ;; .1 2.3 , BTC F 309 SF ; : 5.7 SF t t.. . 5u 547 SF . SF _ ...................................:. > . ATD nji�„ ......... , 918 SF .. 001B 48 F 8 3S » :»»,..»,.,n. , »,. , ;z . :.. STAID Is01 800A s rn #� rr's� ` PPUM _ . » 1. A HR8C-2 .. 1. ST.8s E k z I% I is : s:f 3s . I.. .. ....... ...... .... .... . :;;- ...... : r ,.,:.::., . ..... ............. ::.z .,:.,:. .:: a �i. ::....:.:.::»..,:. s.s .:. i:i .................... .,...,,.:., ....::.:.:..:n,.n.,,.::::.>.,..::: .: _. ............................ , , r I 1.i .. ;; t .r ... :....... 4 :i a ....,...,.. ` fr+. ,,: ,. .. 11 r. r.. ri., ..-........ ... ; ., ;...., t s, ' .; , 3 "it .. ., .. / # ., ..:c: ..... ill s .. - , .� . , .,. , , , . :............. .... i.::. ...:.j .. ....It. ,. s ., t. ,.. ..it, .. .. : 1. ..:� /•;: t.............: " .. .: ; {S RS I ER< ;. i . ,' f:: ;k ;; r ... .................... t .. .:. �k.. y .. , ... ... .... , .,:. 1. D1. I. < .... ... r k - .. �. r .� .. .... .>- . I y 3 i �� :, ..... :. ... .: is r FS ., C.. r.> . . .. - - - T7.9 - - ,... - - - I. 1 -- ::.,:'EF EF' EF EF E EF ... ., EF. it - �:: RISER :, ;<: ; .1 .: : FI: AE:, t .16 A .:7 A 1 A .19 �A .20# �.. . ; a.15 :.:A :,.: }I(, .. .. ... ..: /.,. - TS - t� ..:. , ... .. :Y. ,. ...... .. ... S :�., ,::' ,.. r. „ .; , :r : .. . r ....».. .... ... ...........:....... L»..... ...:,.. .:.. .:.,... , .. s ...... ". ,.,,.", ,. ....,.:. 1 .;. < s iE :: I I I I I. :.: ; I it RISER i RISER CORRIDOR t! . "'.' ................. I. {::;:- ATJ ATH [_.___1 . _ a£ ::, it, #^ ,....» ...»....:..........»..,,t, »»»,,,,.»» ,,,,»»»»,,.,,».,....,,,,,.»,»».....»»:.,,» ,...n.,,»...: ,.».»,:»» »..,,.......»,.».,........n,»».»,.,,,».»»,,,»,.,.. ,......_...» ..»».»., »:.»..a, »...»»:..»,,..,»»..,,.».,.»,.,..,. ,.»................,»». _._....._.......... , » n ,...... ....................... ... „ .............. .... ; , f : _, .> # 'r :.::..:.....:: r.:....::.n- :#:: EF - t ;. . ;: '1.........:......: :, ; . ;, ;€ ;: ;:' ,, , » .. ii " ; .f .. .. ... :. ...:n: ......;: ....::....... ...............:: a .13 ii .. .€€.. t . : . . _.... _. . , .. L. :.. ... , . ; " ... :. I itI :,it. ; ;; t I. ::. it ... _ _, .it it ..... t EF EF EF ,,,.. .: A.11 A.10 A.6'it it k •......_� r _ :: :>, , . I 'it :� . s . A .12 A8.9 A$.8- A8.7 ;: »." t :; , . ;, : :, .:; �: ;, ..., - . .: < :. s: t ;; ..s . .. s S,i / f ,.. ). ;. :,...:�.�'S o , ,. S r......... .: . .., .. .; z :, ; ,: i, .....x ,.....,." "........... .. ;i: . r' 5 :, .. ................. r .. »..........».»,,,,_'_","»...:. . ....:::.. . .. , .....:.......: I .1 n.....:.....r , , s3 ,..i. M .1 I .:; . , :.. :: y ? ... ... y ,.. . .. ... , i i# ;# ,�� , s: .. ,__..,...,, 5 1. ,.. .: . . ; , : . .. .... .::..:..:.......:.t; ., ., t n i ii:....s. ��............... ,.: .; t......,..,..1. n ....... "..... :: :..�.-...t ': :. . 'i: S :: I :: ',.<.,: I N I D C E ... I :111, t; : : , ' ,. r > STANiDARD C)NE <; € STANDARD N s u I '� I € STANDARD ONE' aTUC lO : 'w ...`' BEDROOM - BEDROOM - €1. Y STLlIDIO STUDIO BEDROOty€ :; ; STUDIC3°E aT :::: ;':r - S tANIAHD 5 ; LONG m », »:»., .: L03G G ru{SHAFT » , I, sl 15 STANDARD ST £I LON -1 ;Y::; _... ;:it ii 801 803 s 805 807 ix . ,.. , . 3 .... , , , . ; ;,s . [�� . F 338 SF - f 809 811 813 309 SF 571 1. �F 571 SF 310 SF 309 SF 551 SF . , "'�l -3sr # X i # £.'; ttAM T - 1.- -- - ;55 - - - - - - - 3 - - ,- - - - - - e' It i' I I MI % #. '; k : ; S't 'i s > ; 'i { ................�. , r .. it .. s...,.. - � s r f ..__.............»,,,,.,»,,.. ;:.........»".".....",......",:,.,»,»..,»..».,,,,»"....,».:,:............,.,. ;,., ...;»;.:"»».,.:,.,»,»»,., .. : .................... ............................. »--, _.... ...,.,.,..,....,,». - ». ,»»,,,,,,,:,,.,,»j .__......_.,, .,. ..... ............................ .........................>.:.. .............................. .......... ............. ...................... it," .....................................»......................................................,,...............»,................,...... .•,n:,r.-<::,:.::..: .. ..............................................................n................,...............................,.....i=............... '...............-1............ - ,.... .. r.: - :,...,,n ;.::,.........::.._,....:....,..:::::,...."..rr:.:,a,..:.n<«.n:o:.r:.;....... I RM RM 801 RM RM 803 I RM RM 805 1 RM RM 807 I RM RM 809 RM 811 I RM RM 813 1 E4.01 E4.09 E4.08 E4.08 E4.09 E4.09 E4.08 ITM: (TJ) TI TH; ?TG? TF) - ® � 1 v iw i I I. F® R REVIEWED . COMPLIANCE___.WIT. L H : j" tZko - T9 ) DEC 03 2015 : I : i I City of-TukWifa i BUILDING DIVISION i i RECEIVED ,� CITY OF TUKWILA {TA '_/ OCT 1 5 2015 PERMIT` CENTER ISSUE Date I Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /8- = 1'-0" 11 CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT w W 3: O W F_ Y ry Lu W Q J F_ pY (D aF- z N N T� N rr1 V J 3: ULTANT REGISTRATION �' i 5 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826-44 . I SHEET TITLE AND NUMBER I 8TH FLOOR ELECTRICAL PLAN E2.08 ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - HOTEL ROOMS (LEVEL 9) MECH VOLTSIPHASE LOAD MCA DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) UNIT NO. (AM/HP) (A) EXHAUST FANS EF-H9.1 - EF-H9.2 ............................ _......... EF-H9.3 E F-H9.4 ........... .._............ ............ E F-H9.5 .F .- - ..... E-H9.6 ..._.. _.....-E F-H9.7 ............................................. EF-H9.8 EF-H9.9 ......... ................... I ..... - ...... .. EF-H9.10 EF-H9.11 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-H9.12 ............................................. EF-H9.13 EF-H9.14 ............._........ -- _....--- EF-H9.15 TT^EF-H9.16 EF-H9.17 .... _......... ...................... EF-H9.18 EF-H9.19 EF-H9.20 _ -EF-H9.21 SINGLE -PACKAGE VERTICAL HEAT PUMP UNITS SPVHP-9.1 SPVHP-9.2 SPVHP-9.3 SPVHP-9.4 SPVHP-9.5 ^SPVHP-9.6 SPVHP-9.7 ........................................... SPVHP-9.9 SPVHP-9.10 27711 3.4 KW 17.4 A MR -SW - - 2#12, #12G NOTE 1 400 2 SPVHP-9.11- SPVHP-9.12 ....-........ __........... SPVHP-9.13 SPVHP-9.14 SPVHP-9.15 --.................. .................. SPVHP-9.16 SPVHP-9.17 SPVHP-9.18 SPVHP-9.19 SPVHP-9.20 ----------------- _... ........ SPVHP-9.21 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE NEXT TO MECHANICAL UNIT. ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 9) MECH UNIT NO. VOLTS/PHASE LOAD (AAIN/HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUST FANS EF-A9.1 EF-A9.2-- EF-A9.3 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-A9.4 EF-A9.5 EF-A9.6 _..- ..... .._........ _.._........ EF-A9.7 EF-A9.8 E....... F-A9.9 EF A9.10 EF A9.11 ........................................ - EF-A9.12 EF-A9.13 ----...--------------....... - EF-A9.14 EF-A9.15 EF-A9.16 EF-A9.17 EF-A9.18 - EF-A9.19 EF-A9.20 EF-A9.21 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. 3 w 3 0 (L Z J a 0 0 N 0 O O -0 N. W U) Kj N 0"" O 0 � O ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB 'LAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 1_f� W 3: O W D- O w Q W � p Y V Q H z M CV T� CV vJ 4< ULTANT REGISTRATION v SIDNAL'f 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826.4"7 FAX: (206) 8264"6 SHEET TITLE AND NUMBER 9TH FLOOR ELECTRICAL PLAN E2.09 ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - HOTEL ROOMS (LEVEL 10) MECH VOLTS/PHASE LOAD MCA DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# FM NOTES FRAME (A) FUSE (A) UNIT NO. (A/W/HP) (A) EXHAUST FANS EF-H10.1 --EF-1­110.2 _ EF-H10.3 ........ E F-H 10.4 __..._... ._. .-_.... EF-H10.5 EF-1­110.6..._ E F-H 10.7 -EF-H10 :8..._.... EF H10.9 EF-1-110.10- 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-H10.11 ............._..................... EF-H10.12 EF-Hi 0.13 EF-H10.14 EF-H10.15 EF-H10.16 EF H10.17 EF-H10.18 EF-H10.19 -EF-H10.20 SINGLE -PACKAGE VERTICAL HEAT PUMP UNITS SPVHP-10.1 SPVHP-10.2 ............................................. SPVHP-10.3 --............ -....... .-............... SPVHP-10.4 SPVHP-10.5 SPVHP-10.6 SPVHP-10.7 SPVHP-10.8 SPVHP-10.9 277/1 3.4 KW 17.4 A MR -SW - - 2#12, #12G NOTE 1 400 2 SPVHP-10.10 --- -- SPVHP-10.11 ............. --------............. _.... SPVHP-10.12 SPVHP-10.13 -......... _. .... ........................ SPVHP-10.14 SPVHP-10.15 SPVHP-10.16 SPVHP-10.17 SPVHP-10.18 SPVHP-10.19 ........................................... SPVHP-10.20 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION, 2.) PROVIDE MOTOR -RATED SWITCHAS DISCONNECT. LOCATE NEXTTO MECHANICAL UNIT. ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 10) MECH UNIT NO. VOLTS/PHASE LOAD (ANV/HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUST FANS EF-A10.1 ............................................ EF-Al0.2 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-A10.3 EF-A10.4 EF-A10.5 EF-A10.6 EF-A10.7 EF-A1_0.8 EF-Al0.9 EF-A10.10 EF-A10.11 EF-A10.12 EF-A10.13 EF-A10.14 EF-A10.15 ............................................ EF-A10.16 EF-A10.17 --._........._........................... EF-A10.18 EF-A10.19 EF-Al0.20 EF-Al0.21 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. TB.9 TB �. TA I ! I ' I i ! GENERAL NOTES ! 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF ;. T'•. RISER CIRCUITS RM 1023 - -� H HP10-21 RM 1018 F ..: 3 _ ;F-=YI^... I'� f k ' A HR10A-55 H A HP10-39 HR10A-50 � _r I EF EF 289 SE PVH B 10.10 HR10A 57 L. .......! H10.9 10.1 C - HR10A 59 B HR10A-52 E5.01 C HR10A-54 E5.01 P� I FSD RISER 1 1T2 ;�i;G RM 1021 10.9 STx3 00� RISER 'i ! ` EF H1011 S i.AZI PVH H 10.11 HP10-19 - 5T 103 SD4 i RISER `0�1- A HR10A-49 FM5 306 SI" B HR10A-51 ` -I C 1HR10A-53 RISER X T6.1 -- ---- T7 , aLVIEVED .FOI4 co I PLIANCE WITh �FPA 70 - NEC iDEC- 0 3 2a_i - ----� 9 i$ity of-Tul(Wila BUILDING DIVISION RM I RM 1001 RM I RM 1003 RM I RM 1005 RM I RM 1007 RM I RM 1009 RM I RM 1011 RM I RM 1013 KM I KM 1 Ul 0 KM KM 1 Ul / Km KM I u y RM r-'m i vc r mw rNIn i v c. E4.01 E4.09 E4.08 ! E4.08 E4.09 E4.09 ( E4.08 E4.08 E4.09 E4.09 E4.08 E4.04 RECEIVED CITY OF TUKWILA I i TM i ,Tj 6T, TG) ,`TF l TE lam) TB' TA 6 1 10TH FLOOR ELECI-RICAL PLAN OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-O" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT W OW Y a3�t o wQ W J r Y V Q I�- z N N T� i N U) CONSULTANT IEGISTRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 82644447 FAX: (206) 8264446 SHEET TITLE AND NUMBER 10TH FLOOR ELECTRICAL PLAN E2.10 T9 1 - - i V K 3 0 a Z a J a 0 0 J L� F- T10 I N N Ld IN 0 \ O M O \ � O ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - HOTEL ROOMS (LEVEL 11) MECH UNIT NO. VOLTS/PHASE LOAD (A/W/HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUSTFANS EF-H11.1 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-H11.2 EF-H11.3 EF-H11.4 EF-H11.5 EF-H11.6 EF-H11.7 E F-H11.8 EF-H11.9 EF-H11.10 EF-H11.11 EF-H11.12 EF-H11.13 EF-H11.14 EF-H11.15 EF-H11.16 EF-H11.17 EF-H11.18 EF-H11.19 EF-H11.20 EF-H11.21 SINGLE -PACKAGE VERTICAL HEAT PUMP UNITS SPVHP-11.1 277/1 3.4 KW 17.4 A MR -SW - - 2#12, #12G NOTE 1 400 2 SPVHP-11.2 SPVHP-11.3 SPVHP-11.4 SPVHP-11.5 SPVHP-11.6 SPVHP-11.7 SPVHP-11.8 SPVHP-11.9 SPVHP-11.10 SPVHP-11.11 SPVHP-11.12 SPVHP-11.13 SPVHP-11.14 SPVHP-11.15 SPVHP-11.16 SPVHP-11.17 SPVHP-11.18 SPVHP-11.19 SPVHP-11.20 SPVHP-11.21 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE NEXT TO MECHANICAL UNIT. ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 11) MECH UNIT NO. VOLTS/PHASE LOAD (A/W(HP) MCA (A) DISCONNECT CONDUIT WIRE FNEL-CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUST FANS EF-Al 1.1 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-Al 1.2 EF-Al 1.3 EF-Al 1.4 EF-Al 1.5 EF-Al 1.6 EF-Al 1.7 EF-Al 1.8 EF-Al 1.9 EF-A11.10 EF A11.11 EF A11.12 EF A11.13 EF-A11.14 EF A11.15 EF-A11.16 EF-A11.17 EF-A11.18 EF-A11.19 EF-Al 1.20 EF-Al 1.21 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. GENERAL NOTES 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF RISER CIRCUITS PLAN NOTES O1 LOCATION TO BE DETERMINED BY PLUMBING DESIGN. RM RM 1102 RM RM 1104 RM RM 1106 RM RM 1108 RM RM 1110 RM RM 1112 1 - E4.25 E4.02 E4.02 E4.09 E4.09 E4.02 - I ONE BEDROOM I STANDARD ONE I STANDARD ONE I STUDIO STUDIO STANDARD ONE WEST BEDROOM BEDROOM STANDARD STANDARD BEDROOM 1102 1104 1106 1108 1110 1112 483 SF STAIR 001 554 SF 547 SF 309 SF 309 SF 547 SF I ST 1101 I I I I I I RISER SD1 - I I I I I FED EF RISER EF EF EF EF EF EF . 4 FIREQ.ARM IC1 -RISER - - - - - - - FM1 RISER RISER CORRIDOR 1TJ 1TH 1100 EF -EFEF EF EF EF EF EF - All .9 -- - - STANDARD ONE STANDARD ONE STANDARD ONE STUDIO BEDROOM STUDIO BEDROOM- BEDROOM - STUDIO STANDARD LONG STUDIO WEST STANDARD ( LONG LONG I STANDARD TYPE A I TYPE A - 1101 1103 1105 1107 1109 1111 1113 338 SF 309 SF 571 SF 571 SF 310 SF 309 SF 551 SF I I I I I I RjE4. 1101 RM RM 1103 RM RM 1105 RM RM 1107 RM RM 1109 RM RM 1111 RM RM 1113 E4.09 E4.08 E4.08 E4.09 E4.09 E4.08 �I I (TM) TJ TI', (TH) (TG) TFi TD.2 I RM 1104 PVH H HP10-28 A HR10B-8 B HR10B-10 C HR10B-12T�.2 E5.01 RM 1102 H HP10-26 PVH A HR10B-2 B HR10B-4 RISER C HR10B-6 RM I RM 1118 LV3 E5.01 - E4. G7 - - - - - - - - PF TB.9 I KING NORTH w/ DEN RM 1118 1118H H HP10-42 _._ 386 SF A HR10B-50 B HR10B-52 _ C HR10B-54 P 9 E5.01 STA ST- 13 I RM 1116 H HP10-40 KING WIDE A HR10B-44 1116H B HR10B-46 331 SF C HR10B-48 PVH E5.01 RM 1114 -~I - KING H HP10 -38 FP-V-H-R STANDARD A HR10B 38 1114H B HR108-40 307 SF C HR10B-42 I E5.01 RM 1112 KING H HP10-36 STANDARD A HR108-32 1112H B HR10B-34 PVH 302 SF C HR10B-36 E5.01 I RM 1110 KING H HP10-34 PVH STANDARD A HR10B-26 -E 1110H B HR10B-28 302 SF C HR10B-30 E5.01 RM 1108 KING H HP10-32 STANDARD A HR10B-20 1108H B HR10B-29P`VH_R 307 SF C HR10B-24 E5.01 RM 1106 KING STANDARD H HP10-30 Fp_vFR 11 o6H A HR106-14 307 SF B HR10B-16 C HR10B-18 E5.01 QUEEN QUEEN TUB 1104H 333 SF QUEEN QUEEN 11E 333 SF TB.B.1 I I EF EF RISER SD4- FSD RISER 1 T2 iC EF RISER IC2 RISER FM5 I EF EF 1. 2 HEF EF RISER 1 T3 I EF_ EF I EF EF H H 1. I IDOR - 1100H EF EF H RISER 1 T5 EFF EF I EF EF RISER EF 1T6 F EF TA RM 1123 H HP10-24 KING NORTH A HR10B-55 1123H PVH B HR10B-57 289 SF C HR106-59 E5.01 KING RM 1121 STANDARD PVH H HP10-22 1121 H A HR10B-49 306 SF BI HR1 OB-51 C HR10B-53 _ E5.01 �2 QUEEN QUEEN RM 1119 TUB H HP10-20 1119H A HR10B-43 338 SF PVH B HR10B-45 C HR10B-47 E5.01 - RM 1117 QUEEN QUEEN PVH H HP10-18 1117H A HR10B-37 342 SF B HR10B-39 C HR10B-41 E5.01 KING STANDARD RM 1115 1115H H HP10-16 303 SF PNH 14 A HR10B-31 B HR10B-33 C HR10B-35 E5.01 KING RM 1113 STANDARD g-p;7HA H HP10-14 1113H A HR10B-25 306 SF B HR10B-27 C HR10B-29 - - -- - E5.01 - 14 ,r RM 1111 QUEEN QUEEN H HP10-12 1111-H A HR10B-19 338 SF PVH B HR10B-21 b C HR10B-23 E5.01 RM 1109 QUEEN QUEEN EFTA H HP10-10 1109H A HR10B-13 338 SF B HR10B-15 C HR10B-17 E5.01 T5 RM 1107 QUEEN QUEEN H HP10-8 1107H A HR10B-7 335 SF I Fp-TR B HR10B-9 C I HR10B-11 E5.01 RM 1105 QUEEN QUEEN p;7H H HP10-6 11 o5H A HR10B-1 339 SF B HR10B-3 C I HR10B-5 E5.01 - - - T6 KING STANDARD RM 1103 1103H H HP10-4 TRASH 306 SF 10.1 A HR10C-10 RISER - _ EF PVH._.:- 2 BEDROOM - - SD2 - - - - - - _ HR1 OC T7 ) COURTYARD 27SF I RISER C HR10C-14 RISER FM2 FSD HOTEL ELEV RES ELEV 1118 lTTM LOBBY RISER RISER RISER LOBBY E5.01 920 SF b'• 1TD Fk0AIR 002 92TC 1100B SOUKING THEAST RM 1101 1100A 236 SF I(� ST1102 RISE 145 SF RISER EF CORNER PVH H HP10-2 � RISE FM4EL CT4 A_, V 1C3 1101 H A HR10C-16 I 332 SF B HR10C-18 RISER HR10C-7 69 6 - O IS DATA C HR10C-20 STORAGE 1100D E5.01 -- - - - T7.9 EF RISER IR-7 A-11 - RISERS RISER 17 4TC � 3TC - - - ---- _4 RISER JQ- o -HR10C4RTgt= R BEDROOM- STUDIO STUDIO BEDROOM - TWO BEDROOM LONG STANDARD STANDARD LONG CORNER 1115 1117 1119 1121 1123 571 SF 310 SF 309 SF 571 SF 892 SF 4FPA 70 - Nbh DEC 0 3 2015 I I l _ City Of Tukwl a RM RM 1115 RM I RM 1117 RMI RM 1119 1 RM RM 1121 RM RM 1123 BUILDING DIVI'` I I I E4.08 E4.09 E4.09 E4.08 E4.04 1 RECEIVED CITY OF TUKWILA TE,' (TD) (TC) (,TB TA.6 n 11 TH FLOOR ELECTOCT 15 2015RICAL PLAN - ` ,�8• -0• PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-0.1 CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT Lu 3: O Lu Y z a� Lu O Lu >g pY V aN z N N N v! CONSULTANT RE Ng ,c U Z v� W W Z ch Lu o z U) W W Lo w U) U) M W 0 Z C14¢aLL v) c� w `o�m N H N N REGISTRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 8264446 SHEET TITLE AND NUMBER 11 TH FLOOR ELECTRICAL PLAN E2.11 tT 3 W 0 a Z Q IL of 0 0 LL N 10 0 N_ 7: N W to IN O '-, O \ t O GENERAL NOTES 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF RISER CIRCUITS PLAN NOTES ( PROVIDE SPARE CONDUIT TO ELECTRICAL PANEL FOR FUTURE AC UNIT. ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT -APARTMENT UNITS (LEVEL 12) MECH UNIT NO. VOLTS/PHASE LOAD (A/W/HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A)7 FUSE (A) EXHAUST FANS EF-Al2.1 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-Al2.2 EF-Al2.3 EF-Al2.4 EFA12.5 EF-Al2.6 EF-Al2.7 EF-Al2.8 EF-Al2.9 EF-Al2.10 EF-Al2.11 EF-Al2.12 EF-Al2.13 EF-Al2.14 EF-Al2.15 EF-Al2.16 EF-Al2.17 EF-Al2.18 EF-Al2.19 EF-Al2.20 EF-Al2.21 EF-Al2.22 EF-Al2.23 EF-Al2.24 EF-Al2.25 EF-Al2.26 EF-Al2.27 EF-Al2.28 EF-Al2.29 EF-Al2.30 EF-Al2.31 EF-Al2.32 EF-Al2.33 EF-Al2.34 EF-Al2.35 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. � TB.1 T8-9 ( TA I aS0 SF i RM RM 1235 12.2 I �... E4.12 RISER !Ai 1T3 . _-- .- .....-.......--- - - - -- :.......: .. g; r<m KM I GJL i 578 SF I :: IW RM RM 1233 E4.13 E4.13 J �. t STANDARD J . STUDIO STUDIO 1 TA DARD ;" -tdISHAFT 1 CORRIDOR 12 �tl . '1231 3. RM RM 12,301SF _ GO SF RM I RM 1228 E4.09 I%IRI I I\IYI IG.VI 1\IYI 1\IVI IX-v" I 1\IT1 I 1\IVI IGV�J I 1�1.1 1\ITI 1Lwf I ...n .N... .--- rlll:-q .%..1 -. 1-1 .-.v I ..... .�... .-.- i...........-.LI i -----.....I-I ---...._.__.E4.01 E4.09 E4.08 E4.08 E4.09 E4.08 E4.08 E4.09 E4.09 E4.08 (TM) THj (TGI `TF, (TE TD; TCI I I t �TB, T 6 1 12TH FLOOR ELECTRICAL PLAN " 1/8" =1'-0' DEC 0 B 2015 nlVISION RM I RM 1231 E4.09 RM I RM 1229 E4.09 T5 T9 ) RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB ,EYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT W O W Y z IY Q W J p Y V Q F- z M N N U) Q CONSULTANT REGISTRATION v SIaNAL ��� 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER 12TH FLOOR ELECTRICAL PLAN E2.12 l T9 - g TB. i A , GENERAL NOTES 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF RISER CIRCUITS _ _ _ _ J T1 - -, PLAN NOTES RM RM 1336 1O PROVIDE SPARE CONDUIT TO ELECTRICAL PANEL AND E4.15 SPARE J-BOX WITH BLANK COVER PLATE FOR FUTURE AC - I UNIT. _. FSD RISER 1 T2 :' E ��:DR �Cffil J Nt CiaRNI: R 313, RISER,I` - ...,---- 1 SD4 ;�<' SFISER R ..FM5 RM RM 1339 i E4.14 --- -... - - ------------ - ------------- - - - - . - - -- I - - --- -- - x : ... ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 13) MECH UNIT NO. VOLTS/PHASE LOAD (AAW/HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUSTFANS EF-Al3.1 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-Al3.2� EF A13.3 EF-Al3.4 EF-All3.5 EF-Al3.6 EF-All3.7 EF-All3.8 EF-Al3.9 EF-A13.10 EF-A13.11 EF-A13.12 EF-A13.13 EF-A13.14 EF-Al3.15 EF-All3.16 EF-Al3.17 EF-A13.18 EF-A13.19 EF-A13.20 EF-Al3.21 EF-Al3.22 EF-Al3.23 EF-All3.24 EF-A13.25 EF-A13.26 EF-A13.27 EF-A13.28 EF-A13.29 EF-Al3.30 EF-Al3.31 EF-A13.32 EF-A13.33 EF-Al3.34 EF-A13.35 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. RM RM 1318 E4.07- RM I RM 1330 E4.09 RM I RM 1328 E4.09 RM I RM 1337 E4.12 RM I RM 1335 E4.12 - -.... { T3 ) RM I RM 1333 J t.:. - ----- --- _ ...._ T" I .. STU1010 1 STANDARD ............1330 ........................ 327 SF i 1303 € 1wt37 «£ 15'4 } 1315 131E 1 s 323 .' r3• FIRt U y= __l IEWED u.�� f::.::u...uuu f ## f3 �i i>. .. 904 S1 „ # B04 SF 883 SF SP ;04 SF 1 9^ }. 1> £3� S COMPLIANCE WITS 3. g %€ 3# >3 ,a r 35 3' 33'3 3 i N1= PlY-"d £3 I �£ I 0- KEG - I QEC 0 3 2 '015 Y t . 'Y. . . ni.... to u...... .r.:... vii i ". i "a .:...."�:.:..........� 3 . 1. 5 53 ........:3:>:..«>.:%«,<:: io;.•ai.. r•...:...............:3uvw�:�....:r,<«,...,........ <: ,• %3 f CWyy of-YukWila RM RM 1303 ( RM RM 1307 I RM RM 1313 I RM RM 1315 I ( RM RM 1319 I RM RM 1323 I I BUILDING DIVISI®� I E4.10 E4.10 E4.10 E4.10 E4.10 E4.04 RECEIVED I (TJj t TI . NTH; (TGI TTE, F} t(TD) ;TCj TB) T 6 (TA)CITY OF TUILWfLA `J O13TH FLOOR ELECTRllaAL PLAN `J OCT 15 2015 ,�• _, -0• PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB EYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: O w QQ z a3: w� Q Y V QF- C z M N N Q CONSULTANT EGISTRATION 5 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT "E. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER 13TH FLOOR ELECTRICAL PLAN E2.13 cp 3 v W 0 a Z a J a x 0 0 J r N 10 0 N WU) 15 oN, oN, �o RM I RM 1401 E4.01 GENERAL NOTES 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF RISER CIRCUITS ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 14) MECH UNIT NO. VOLTS/PHASE LOAD (A/W/HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUST FANS EF-A14.1 EF-A14.2 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-Al4.3 EF-A14.4 EF-A14.5 EF-A14.6 EF-A14.7 EF-A14.8 EF-A14.9 EF-A14.10 EF-A14.11 EF-A14.12 EF-A14.13 EF-A14.14 EF-A14.15 -EF-A14.16 EF-A14.17 - EF-A14.18 EF-A14.19 EF-A14.20 EF-A14.21 EF-A14.22 EF-A14.23 EF-A14.24 EF-A14.25 EF-A14.26 EF-A14.27 EF-A14.28 EF-A14.29 EF-A14.30 EF-A14.31 EF-A14.32 EF-A14.33 EF-A14.34 EF-A14.35 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. RM I RM 1406 E4.02 RM I RM 1410 E4.09 RM I RM 1418 -E4.-07 T13.9 TB.1 l TA; i I i i _.. >. ": EF . EF € .................................... 14.2 14.2 RM RM 1436 ...' .. F ..... ..... E4.15 FSD RISER �1T2 ;s AEI RISER "OR- ER �f 3 S134 i E RISER -- 13 ...:51 FM5 592 SFRM RM 1439 E4.14 _... _._ .--...- -- -- -- -......._ - - -; T2 ; STANDARD ONE STANDARD <'ORTH `, n,E .......................----....... 1434 E - - 14-3 7 ' ..y..ti RM RM 1437 RM RM 1434 E4.16 .............. .. _..._ ......:. ..:....._ ..... i, EF E4.12 ........ I' ... . EF 4.3 S TA i?r . ZD STUDIO LONG r.................................. EF (..........................1v�y� .......... RM RM 1435 14.2 360 SF E4.12 RISER 1T3 - ----- - - -- - - -- -- fn - i ....... i EF 1. .... . EF ; A14.3 a !i I ..... ONE BEDROOEv1 ;. .... I ...... A; STANDARD _ GIB= BEDROOM ORTH NOR.TK LONG .....................................::........ 1432 .... RM RM 1432 ------..-------� 78 SF _,. 635 S,- RM RM 1433 E4.13 E4.13 STANDARD � STUDIO � i a-iE'VlE t'ELs i t-,- , OMPLMNCE WI' . NFPAI70 - NEC -- DEC 0 3 2015 T6 T6.1 .......:.;:..i..:::::n.:;::::.......»,...:•::::�:yi.i::;y:o:i:::K�:::�:::......;.:;.:.:.:.::....::::..:ti:iyi'l..yiFn.::�:<:Y.:.:.::».�::::... .: y.....:.::. ..............::................:.........y.........:. ........ ......................................r.::.:-..r::.::r../ni:»f:'ip'.'.:'F.::..,.......................y...:...... �i:I.li ipW: c::.:.....;;..........r: :::.. :::.::...: ,.:.....:::::::::: ::::.::.:::.::..::.._ City of TukWlla RM RM 1407 BUILDING DIVISION RM RM 1403 I I RM RM 1413 RM RM 1415 I RM RM 1419 I RM RM 1423 I E4.10 E4.10 E4.10 i E4.10 E4.10 E4.04 RECEIVED s j I CIW OF TUKWILA TJ TI TH 1 TF TE ' TD 1 TC TB TA.6 TA �� �"� 14TH FLOOR ELECTRICAL PLAN `-� 0 C T 15 2015 1 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB :EYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 0 W 3: OW F Y z a- O W Q W J pY V aH z CM N N v) Q CONSULTANT REGISTRATION 5 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 S HEET TITLE AND NUMBER 14TH FLOOR ELECTRICAL PLAN E2.14 Ld W 0 IL Z CL J m 0 0 J N I 0 Lo T O N La to 10 o \ 0 \ d' O GENERAL NOTES 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF RISER CIRCUITS ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 15) MECH UNIT NO. VOLTS/PHASE LOAD (A/W/HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUSTFANS EF-Al5.1 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-Al5.2 EF-Al5.3 EF-Al5.4 EF-Al5.5 _EF-Al5.6 EF-Al5.7 EF-Al5.8 EF-Al5.9 EF-Al5.10 EF-A15.11 EF-A15.12 EF-A15.13 EF-A15.14 EF-A15.15 EF-A15.16 EF-A15.17 EF-A15.18 EF-Al EF-A15.20 EF-A15.21 EF-A15.22 EF-A15.23 EF-A15.24 EF-A15.25 EF-A15.26 EF-A15.27 EF-Al5.28 EF-A15.29 EF-A 15.30 EF-A15.31 EF-Al5.32 EF-A15.33 EF-A15.34 EF A15.35 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. T8.9 TBA TA ! �. y I I -- T� l Y.r x,,,,_R i FEF FEF ................... _................. 1527 15.2 RM RM 1536 �. :r E4.15 FSD ISER '.' .. .. -f -ONE NE NER :RISER : ..........��......... i STR 1:iO3 SD4 I MISER ,......: 153.. .....................`........... FM5 592 S: RM RM 1539 I E4.14 t .............., -- - .. - µ 2 ti € s;NDARD ONE SEDROisN1 NOR yST.A1•{i.3ARD ..................................... i '534 I �• .. 537 _. RM RM 1537 RM RM 1534 3,10 E4.16 ' i �..:.... .. EF :: E4.12 � , < I I: . EF 15.3 ST.ANOARD STUD 0 I»O G EF . 1535 i 15.2 _ RM RM 1535 35ur= S: E4.12 .. RISERad 1T3 : - - I .::.y ..T3 " - -- --..... 1' a »:..:.. w.:..:: EF -- . ; ONE BEDR{.sGl`,rt NORTH LON 153.�s 35 S .._ 35A SF RM I RM 1533 E4.13 - - - --1 T4 / RM I RM 1531 E4.09 RM I RM 1529 E4.09 ( T5 <::...................................._................._,<::.<...................................»......................::....:................................. .............. ....:..: ....;....% 2 BEDROOtY9 s 2 BEDROOM % F 2 BEDROOI'`k� 2 BEDROOM _..... :',% € < (��rt3 t�EDfiOGIYI � ' y: k STUDIO WEST LIEN DEN ; .. DEN �vISHAFT DEN TYPE A CORNER _._.:.._.,..» ..:. »._ ».._,.:.:.-,,._• L I �4 ?IMP 9=L.� >�• i .5 £ ; i € :6 1001 1503 1�07 1511 1515 » ii :.s j( [j 5 .. ....»»...............3 4vTTwTw�� y c n " i rti L .. E '. . l� V E �� .; yt �PL� 4 SF0 aF 89 SF I..Y< 338 SF 904 SF 004 �F 883 �F 0 ,., Fr AP"r A P - - - T ( i ice" I BSI' %f 5 5% I-� V 3 IIH i I •�i" 0 015 i 5 i £ s> f% y: c% i% i y c t ... i .: c . :................................................ : City 3UILIND DIVIS� ► of Ttxkwila[�w � RM RM 1501 I RM RM 1503 I RM RM 1507 � I RM RM 1511 ( RM RM 1515 I I RM RM 1519 RM RM 1523 � E4.01 I E4.10 E4.10 E4.10 E4.10 E4.10 E4.04 i RECEIVED ` CITY OF TUKWILA i ! TJ + TI TH TG) r TF TE TD' TB TAB 1 15TH FLOOR`tLECTRICAL PLAN OCT 15 2015 1/8" =1'-0, PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = V-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 0L ui 3 O w Y ry Z a-� w Q O w o o V Q IF- z OM N N U) CONSULTANT REGISTRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31. SEATTLE, WA 98103 PHONE: 206 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER 15TH FLOOR ELECTRICAL PLAN E2.15 3 3 0 a z Q 0- Of 0 0 J li TD.2 GENERAL NOTES 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF RISER CIRCUITS - PLAN NOTES O1 PROVIDE EMPTY CONDUIT WITH PULL -STRING FROM 16TH 1 FLOOR TELECOM ROOM TO JUNCTION BOX. ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 16) MECH UNIT NO. VOLTS/PHASE LOAD (A/W/HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUSTFANS EF-A16.1 120/1 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-Al 6.2 EF-Al 6.3 EF-Al 6.4 EF-Al 6.5 EF-Al 6.6 EF-Al 6.7 EF-Al 6.8 EF-Al 6.9 EF-A16.10 EF-A16.11 EF-A16.12 EF-A16.13 EF-A16.14 EF-A16.15 EF-A16.16 EF-A16.17 EF-A16.18 EF-A16.19 EF-A16.20 EF-A16.21 EF-A16.22 EF-A16.23 EF-A16.24 EF-A16.25 EF-A16.26 EF-A16.27 EF-A16.28 EF-A16.29 EF-A16.30 EF-A16.31 EF-A16.32 EF A16.33 E F-A16.34 EF-A16.35 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. RM I RM 1602 RM I RM 1604 E4.25 I E4.02 i I I ONE GEDROOM STANDARD ONE WEST BEDROOM 1602 1604 483 SF 554 SF STAIR 001 ST 1601 RM RM 1606 E4.02 STANDARD ONE BEDROOM 1606 547 SF RM I RM 1608 RM I RM 1610 E4.09 E4.09 STUDIO STANDARD 1608 309 SF RM I RM 1612 E4.02 T6Y.9 TBA (TA I I � I DATA CONNECTIONS OWER CONNECTIONSI ;FOR DISPLAY SCREEN FOR DISPLAY SCREEN O WP J J WP ONE BEDROOM NW CORNER 1636 EF EF RM RM 1636 1 472 SF AR19-25,27 E4.15 I RISER SD4 FSD RISER (&1T2 ONE BEDROOM I IC NE CORNER STAIR 003 RISER 1639 ST-1603 IC2 592 SF RM RM 1639 RISER FM 5 [E4.14 - - - - - T2j STANDARD ONE BEDROOM STANDARD NORTH W DEN STUDIO LONG RM RM 1634 1634 1637 RM RM 1637 ---� E4.16 EF 360 SF E4.12 I I EF 16.3 STANDARD STUDIO LONG EF 1635 RMI RM 1635 360 SF E4.12 1 I RISER -- - - - - --1 T3 - - - - - T3 EF A EF ONE BEDROOM STANDARD NORTH 1632 RM RM 1632 578 SF E4.13 I STUDIO STANDARD RM RM 1630 1630 E4.09 327 SF STUDIO STANDARD RM I RM 1628 1628 E4.09 327 SF I i RM I RM 1626 RISER E4.18 RM RM 1618 LV4 E-4;07- - L i I ONEBEDROOM LARGE 1626 669 SF RISER ® = E�F TBA �5 RISER 1T6 I EF i i ONE BEDROOM NORTH LONG 1633 �, 635 SF RM RM 1633 E4.13 STANDARD STUDIO W/SHAFT 1540 RM RM 1631 354 SF E4.09 STANDARD STUDIO W/SHAFT 1538 RM IRM1629 354 SF I E4.09 - - - - T5 ONE BEDROOM LARGE 1627 669 SF RM RM 1627 E4.18 i STUDIO STANDARD ONE 2 BEDROOM SD2 _ STANDARD BEDROOM COURTYARD RISER RISER FSD 1610 309 SF 1612 547 SF 1618 920 SF 1 TM FC RES ELEV FM2 Dio, RISER q. LOBBY SER� FM3 �R2TE�TORAGE 1600-A 1 TD IC 1600-B � ONE BEDROOM 236 SF RISER' AIR 002 145 SF SE CORNER 3 IC3 ST 1602 RISER 1625 EL c.E6/.CK' V 1 T8 657 SF RM RM 1625 16w-t RRISER ISER 69 SF 0)6TCDATA 1 E4.11 FS 5_1 STORAGE 1600D RSER _T7--.9 EF EF f7EF RISER 1600J RR EF R Vl 46 SF 3TCFIREQARM IRISE T RISER 4TC- IG ►r Ic FM1 RISERQ ---- - -- 2 BEDROOM 2 BEDROOM STUDIO WEST DEN DEN 1611 1615 I 1619 1623 { I - 1601 1603 1607 883 SF 904 SF 904 SF 892 SF REVI� ED FOF' COMP.rIANCE W� g_ 338 SF 904 SF 904 SF NFPA 7®" NEC T9- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - i DEC 0 3 2015 _ ___-. _ of.Tukvvila BUILD D I V RM RM RM RM 1601 RM RM 1607 1 RM RM 1611 RM RM 1615 RM RM 1619 RM RM 1623 E4.01 E4.10 E4.10 E4.10 i E4.10 E4.04 I RECEIVED CITY OF TUKWILA 'TM; TJI TI'iTH ��TG �TF TEI� TD��; 16TH FLOOR ELECTRICACPL0AN TAs 1 U�I) i ZU)3 ,/8^='I-0• PERMIT CENTER 1603 E4.10 ISSUE 0 Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT W 3: O W Y a 3: O Lu Lu >g pY V Q F- z co N N N U) Q SULTANT id it U z u w w z co w c9 Z U) w w cn w U) U) o� Lu p o -DO z CC ! � x ~ M CD W coo c`no Cacom F- NNCVN 'ISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER 16TH FLOOR ELECTRICAL PLAN E2.16 RM I RM 1701 E4.01 GENERAL NOTES 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF RISER CIRCUITS ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 17) MECH UNIT NO. VOLTS/PHASE LOAD (A/W/HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUST FANS EF-A17.1 12011 1/20 HP 1.0 A MR -SW - - 2#12, #12G NOTE 1 80 2 EF-A17.2 EF-Al 7.3 EF-A17.4 EF-A17.5 EF-A17.6 EF-A17.7 EF A17.8 EF-Al 7.9 EF-Al 7.10 EF-A17.11 EF-A17.12 EF-A17.13 EF-A17.14 EF-A17.15 EF-A17.16 EF-A17.17 EF-A17.18 EF-A17.19 EF-A17.20 EF-A17.21 EF-A17.22 EF-A17.23 EF-A17.24 EF-A17.25 EF-A17.26 E F-A 17.27 EF-A17.28 EF-A17.29 EF-Al 7.30 EF-A17.31 EF-Al 7.32 EF-A17.33 EF-Al 7.34 EF-A17.35 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. I TJ � RM I RM. 1707 E4.10 RM I RM 1718 --------- E4:07-- --- RM I RM 1715 E4.10 TS s TB.1 ; TA Y I I • I i ? • EF EF RM RM 1736 ------ 1731 E4.15 SD : RISER ` £l' 1T2 : E� €� \ e ��I d_�R STAID PA3. RISER' - SD4 i 173ti - T7t; RISER 582E I ...FM5 RM RM 1739 I E4.14 ---- - - - - - -( T2 ONE SEDROO DE�1 " : T ! LR STA :NDARD FLR RM RM 1737 RM RM 1734 - n -f---' -- -_ ti: M E4.16 �.___ E4.09 EF 17.2 i e EF I S i'i1 �A STAND; :RI:: E eCRl-H 17351 17.2 RM RM 1735 -27 SE' I RISER 1T3 q. ............... _.. --........_--...-- ... ... .. -- TA 1 t <.. EF ItA17.2 r' I j': ..... I .. . . ::. . 9,NE SE":DROON € STANDARD STANDARD ND:RT:I 17'T;a NORTH TH 17TW FLR I EAR RM RM 1732 - - -- - - 132 •� i _._ ...................................... RM 1 E4.13 , M 733 S78 SI I 57S GE E4.13 ».. a, : i __.. ....:, is STUDIOf STUDIES STANDARD STANDARD6: I` NORTH as,'SHAPT I RM RM 1730 .1 7T SLR 1. RM RM 1731 �IE�R .........�.................. ... 17TH FLR :: SG E4.09 I ' 1731 E4.09 7 SE EF RISER 1E 3 321 SF I 17.2 am t 1 T5 I E3 I STUDIO 17,.2 EF STUDIO STANDARDL�"� STANDARD 1?T)-T FLR } IdERTH `dsA.Sr.ArT ............... .......: 17rH FUR RM RM 1728 t 728 I �;,........_......................_ i RM RM 1729 E4.09 I 327 SF 1 f_- 15.1 I E4.09 , = � T5 f STANDARD ANDARD ONIE �) (TH) ;TG) (TF; ;TEI (TD1 I I- I I %AVI I/ f-V I j E4.04 I TC ; (TB ; TA.6 `J 1 17TH FLOOR ELECTRICAL PLAN AEVIWED FUF _0OPLIANCE WITH _ NFPA 70 - NEB ult 0 3 2015 i City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB <EYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: oW Y Z a� oW wQ J QY V Q H z cM N N U) CONSULTANT REGISTRATION v SjQNAL 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER 17TH FLOOR ELECTRICAL PLAN E2.17 3 3. 0 a Z a a Of 0 0 J 4. co co N O 0 co ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT - APARTMENT UNITS (LEVEL 18) MECH UNIT NO. VOLTS/PHASE LOAD (A/W/HP) MCA (A) DISCONNECT CONDUIT WIRE PANEL -CIRCUIT# CFM NOTES FRAME (A) FUSE (A) EXHAUST FANS EF-A18.1 EF-A18.2 120/1 1/20 HP 1.0 A MR -SW — - 2#12, #12G NOTE 1 80 2 EF-A18.3 EF-A18.4 EF-A18.5 EF-A18.6 EF-A18.7 EF-A18.8 EF-Al8.9 EF-A18.10 EF-Al8.11 EF-A18.12 EF-Al8.13 EF-A18.14 EF-Al8.15 EF-Al8.16 EF-A18.17 EF-A18.18 EF-A18.19 EF-Al8.20 EF-A18.21 EF-A18.22 EF-A18.23 EF-Al8.24 EF-Al8.25 EF-Al8.26 EF-Al8.27 EF-Al8.28 EF-Al8.29 EF-Al8.30 EF-A18.31 WATER SOURCE HEAT PUMP UNITS WSHP-18-1 208/1 25.6 A 25.6 A MR -SW — — 2#8, #10G 3BRW 18,20 1,320 1,3 WSHP-18-2 6.7 A 6.7 A MR -SW — — 2#12, #12G S1 BR-18,20 250 1,3 WSHP-18-3 6.7 A 6.7 A MR -SW — — 2#12, #12G S1 BR-18,20 370 1,3 WSHP-18-4 12.1 A 12.1 A MR -SW — — 2#12, #12G 213RDS-18,20 730 1,3 WSHP-18-5 25.6 A 25.6 A MR -SW — — 2#8, #10G 3BRDA-18,20 1480 1,3 WSHP-18-6 10.9 A 10.9 A MR -SW — — 2#12, #12G 2BRYD-18,20 410 1,3 WSHP-18-7 23.0 A 23.0 A MR -SW — — 2#8, #10G 313RD-18,20 1310 1,3 WSHP-18-8 15.2 A 15.2 A MR -SW — — 2#10, #10G 2BRC-18,20 810 1,3 WSHP-18-9 10.9 A 10.9 A MR -SW — — 2#12, #12G 1 BRLG-18,20 450 1,3 WSHP-18-10 15.2 A 15.2 A MR -SW — — 2#10, #10G 2BRD18-18,20 890 1,3 WSHP-18-11 15.2 A 15.2 A MR -SW — — 2#10, #10G 2BRD18-18,20 880 1,3 WSHP-18-12 15.2 A 15.2 A MR -SW — — 2#10, #10G 2BRD18-18,20 840 1,3 WSHP-18-13 10.9 A 10.9 A MR -SW — — 2#12, #12G 1 BRWD-18,20 450 1,3 WSHP-18-14 23.0 A 23.0 A MR -SW — — 2#8, #10G 3BRDN-18,20 1250 1,3 NOTES: 1.) REFER TO PLANS AND TYPICAL UNIT PLANS FOR CIRCUITING INFORMATION. 2.) PROVIDE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE PER TYPICAL UNIT PLANS. 3.) PROVIDE INDUSTRIAL GRADE MOTOR -RATED SWITCH AS DISCONNECT. LOCATE NEXT TO MECH UNIT. RM RM 1804 RM I RM 1806'jR4MjM 1808 E4.02 E4.02 .21 ff I I I I I i ii EF l» JA18.1y STANDARD ONE f, STANDARD ONE t < II � B (� EDROOM BEDROOM 18TH BED 18TI I R�301� DEN 1 c�T�l t :. .................................... :5 ; FLOOR SMALL '. :.:;: . STAIR 00 ..., H"'. 180`1 ....................................� ...... ..... ......:.:... ;, `f 07 SF 112 SFIt i S if ............. RM I RM 1819 I I I E4.24 1TG1 TF) TE; RM RM 1823 t'ijlOf.TUkWII� E4.04 I CBUILDING DIVISION. i i i TC r (TB) TA.6 ; TA RECEIVED `J CITY OF TUKWILA OCT 15 2015 n 18TH FLOOR ELECTRICAL PLAN PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = V-0" CHECKED BY: CHL APPROVE D BY: DRAWN B Y: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT W 3: a W Y (L 'S wg > p Y rF_ V Q H z M CV CV U) �ULTANT REGISTRATION v SIaNAL �� 7/15 3 � GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826.4447 FAX: (206) 8264446 SHEET TITLE AND NUMBER 18TH FLOOR ELECTRICAL PLAN E2.18 w 0 z Z) O J N WE 1 N W !2 r7 N O N, O "' � O GENERAL NOTES 1. REFER TO E7.05 FOR BRANCH CIRCUITING OF RISER CIRCUITS FLAN NOTES O1 SUSPEND TRANSFORMER FROM STRUCTURE. O POWER DISC FOR AV EQUIPMENT RACK. PROVIDE NEMA 14-50R RECEPTACLE. 19TH FLOOR MEZZANINE - ELEVATOR MACHINE ROOM POWER PLAN 1/4• = V-0" .......... .:...........:.......... <;.....................,...........;........::............>..........;......... ,;.......... ........... .<;... ...... ;:............ :........... ;.......... :,,.......... ,;.......... .:............. .::........................................-,- €- AR13 20 22 24DW I I I : .............................................:::......... 1 ...................................................:..::.. _::::::::DW 95 .� AR19-33 35 AI�Ti1tEN 20 22 24 26 28 30 AP AIR A 20 CLUB B i i E i i E A A O P1 -i n 39<. I 1 I I I iTMI �TJ) u TH} ,TGi I CTF i n LOUNGE ELECTRICAL PLAN 1 tTE TD) ETC} �TB TA.6 i T6.1 I REVIEWED ,FOP POMPL-IANGE-WIT -$---- T9 NFPA 70 - NEC DEC 0 3 2015 I City of -Tukwila UILDING DIVISION TA; RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-O" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB PLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry LLI 3: OW fY (- w Q W J pY V Q H Z N N �TT� N �1 V ) SULTANT REGISTRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER LOUNGE ELECTRICAL PLAN E2.19 0 0 (14 10 O O N .. N wU-) 10 oC'4 0 d- o I 1 RA I t. I i i i i L-- - - - --- -- - - - ----- ... ----- i RA I I I ------- _ - --- --- ---- ----. ----- - - - - - --- I I ' I 1 REVIEWED FOF COMPLIANCE WIT .NFPA 70 - NEB` I ION RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB (EYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 0. W p w Q Q Z a o wQ W J pY ♦D Q H z M N T� N V ! CONSULTANT REGISTRATION 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 8264446 SHEET TITLE AND NUMBER ROOF ELECTRICAL PLAN E2.20 m 0 0 u- N � F O �o N N � O O 4 .s� W ,s CD :- O TD.2 TB.H TBA :'TA! i I I i � LIGHTING CONTROL ZONE LEGEND: GENERAL NOTES i 1. REFER TO E1.00 FOR LIGHTING CONTROL PANEL ----------1 SCHEDULES. - PRIMARY DAYLIGHT ZONE — _ - 2. REFER TO E7.06 FOR BRANCH CIRCUITING OF 3., 3a 5r SECONDARY DAYLIGHT ZONE -- -- APARTMENT WING RISER CIRCUITS. ; . �OC - 3. REFER TO E7.07 FOR BRANCH CIRCUITING OF. HR6 E 3a HOTEL WING RISER CIRCUITS. - r «. I?Y7a HP8 I HP5 HP4 4. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. 3 E L 7a E 7r 3 E _ _ E 5r 5. FIXTURES SHOWN IN DAYLIGHT ZONES WITH— DAYLIGHT ZONE NUMBERS SHALL BE PROVIDED �:. J WITH 0-10V DIMMING BALLASTS AS REQUIRED. �.� `. °" I RISER... �; 5r 5r' "op3 HS3 SUS ' T2F ' E i iL PLAN NOTES _�, 1 GTCPAC E �: AIN i . 3-- 3 f;ISER F 5r 127 T2E 3a 7r O1 CONDUIT FROM LEVEL 2 ABOVE. 4 - - SI E o \ E _. _. _ T2 .............. _ .. __. .. __ _ (7 i PRovTnF (-ONNFCTTnN FOR STGNAGF_ P HP8 � 5 _ O O FRONT DESK VESTIBULE LOBBY HALLWAYS FRONT DESK WALL WASH SWITCH 'a' SWITCH 'b' SWITCH 'c' SWITCH 'd' SWITCH 'e' ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF O O 1505 SF _ 1 ............ 3 LIGHTING SWITCH BANK DETAIL - LOBBY/FRONT DESK CANOPY LIGHTING HS2 I 2 a ^ HR6 NONE 1/a. = 1' a� 1 1 5r �r F r . 7r 15 DUB Ull4U vl v 101UN _ RECEIVED CITY OF TUKWIL A /-\ C TM I TJ TH) TG) TF I TE) TD) TC ; TB 1 TA.6 TA : OCT 5 ZO1J 1ST FLOOR PLAN LIGHTING PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB EYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 0. w OW Y z a3: O w¢ WJ pY QH Z N N ■� N U) CONSULTANT REGISTRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER 1 ST FLOOR PLAN LIGHTING E3.01 FROOF DECK .................................... 233 346 SF 3 r1211 RISER.'...- ....... ........ . ... .. .... E— -2C Il4d*eAxlL-14 ............. ...... .... ........... • c 2 d ..................... FIR [A . ..... ................................. ... ......................... ................ .......... ............. .................... ......................... . .. ..... ...... ..... . ... ..... ....... ELECT. V ..... ..... HS1 L T8 -0 ik. Y9b E H ................. ............... ........... . . .... Pp LJ2 ...... .... . ............ ...... ... ....... ...... V F r AS3 20 I'v fang - ---------- -............. ....... .......................... SAD 2ND FLIP. EDROO FLIP ............. . . D 2ND FLR. 5 k-L;I\j SANDARD. 2ND FLR. .....-........ ..................f.............. ......... ................................... . . ......... ........... .... .. FLR STADARD 2ND FLR. STANDARD. D FLR -------- - --------- ....... ...... -------------- ---- ----------------- . ................................... 2 .idi D i0 EVWE A 338 SF E. 2507 537 SF I 2 2 6S 1 2 21 NFWOrT ,2 - E705S [Tq�— mt- .................................................... .................. . Or 3 2015 II I I'll, -- — I I i ' " I I I ' "-, — I I I I --- I I I I - ---- — I I ---. - I I I - ---- --- I I I - ---- E4.0 E4.03 E4.03 E4.02 E4.02 .03 E4.02 E4.02 E4. -0=1-:-E4.03 E4.02 "r--LE4.02j RECEIVED CITY OF TUKWILA T, f TE� (TD) (Tc) TA.6 (TIM) (Ti) TI TH (TG) (�F TB, (TA) 2ND FLOOR PLAWLIGHTING OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = l'-O" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry w 3: 0 z 0 < > i 03: z < z CN U) CONSULTANT REGISTRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826446 SHEET TITLE AND NUMBER 2ND FLOOR PLAN LIGHTING E3.02 1 I (TMi GENERAL NOTES 1. REFER TO E7.06 FOR BRANCH CIRCUITING OF APARTMENT WING RISER CIRCUITS. 2. REFER TO E7.07 FOR BRANCH CIRCUITING OF HOTEL WING RISER CIRCUITS. 3. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. PLAN NOTES O OCCUPANCY SENSOR SHALL BE SET AS AUTO ON TD 2 TB 9 TBA A I I � I , —1 u s La RM 308 A I HR26-20 E5.01 KING STANDARD --------------------------- I 3081-I ................'................ .... 07S ET E RM 306 A HR26-14 I KING STANDARD " �..:: uCSH RISER �:............... . $07 SE....... T5A: ,:. I ) HR3 »:...... KING STANDARD 1C4F RM 309 I A HR2C-25 I E5.01 T\G 6 1 I.. ............................. ....... ........... ....... .......................................... .. : .. ` y> a r•si i i i y i �( .. h....£.a... 30i ; : SCt3 31 . 31 S 1 1 � .� �CORNER VIEWED FOK _ h w :: LIAi�CE W . SIOI"sF Ci® 548 SF :.; :.. : f 548 CIW ., f . S�8 Sig ,,. ,., 30D �r _ _.. .... .. .:.. ,... . i S s0=� �� � � S NE 7�` � T9 t = 6 < Utz 0 3 ?nl5 's .......... ..................... .................. i_.' _'_ r _ —r.: .................... ............................... :,, , :s:< :: ............ ......... .. r : r : r r, r, r r r i gjty ©f TukWiic RM RM 305 I RM RM 307 I RM RM 309 RM RM 311 I RM RM 313 ( RM RM 315 I RM RM 317 RM RM 319 I RM RM 321 I RM RM 323 I Bui..DING ®(V).,-,w E4.02 E4.02 E4.09 E4.09 E4.02 E4.02 E4.09 E4.09 E4,02 E4.04 RECEIVED n ^, , CITY OF Tk�KWILA �TJ� TI (TH, TGi (TF (TE) (TD, ETC, ,TB TA.6 TA, 3RD FLOOR PLAKLIGHTING OCT 15 2015 va• = r-o• PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT L.L_ W 3 oW Y_ a3: O >g pY V a i=— z cM N �T� N rim V / CONSULTANT :GISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER 3RD FLOOR PLAN LIGHTING E3.43 1E 0 0 N W� LL z Z W U� Y a z 0 z z_ r RM RM E4.2 RM RM 404 E4.02 402 RM RM 406 5 E4.02 GENERAL NOTES 1. REFER TO E7.06 FOR BRANCH CIRCUITING OF APARTMENT WING RISER CIRCUITS. 2. REFER TO E7.07 FOR BRANCH CIRCUITING OF HOTEL WING RISER CIRCUITS. 3. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. PLAN NOTES 0OCCUPANCY SENSOR SHALL BE SET AS AUTO ON. nyOSEDR00 RM RM 418 COURT,YMD ................. ::..:.::_::.::......,.::..............:::................:.::_..,........::.........w..:...............::...............:........,......M...:.........:.........................::.................................:....:.......».::...............:: w........ __H .� ...._:::...:........._......................:...:...,..._. �....:...:................. w...»..::::_..::..:.:..:................. ..,:: .................... . . .................................. k:.H:::n.:k: ::.,.,... .......k.» ...»,....:: :::::.:................::: :............ .........,......:......,:..:....................................:.: __ ...,,........_., ..............._ ...... N.: ........... <,..w. ».,::::,: »:. ::::..::: ...r..R..... ..n...:�:... .: :,.......... H.._:::.:::: x:.:: ......., w ............................................:......:.......................................:. -44 5 + ------------- — -- k S<5 i ST`s..lB{E3 ?;T1�.141�atkl��'3 £�F ;y RM RM 408 E4.09 RM RM 410 E4.09 RM. RM; 412 E4.02 I RM RM 401 RM RM 403 ( RM RM 405 I RM RM 407 ( RM RM 409 RM RM 411 I RM RM 413 E4.01 E4.09 E4.02 E4.02 E4.09 E4.09 E4.02 (TMI ITJ� TI NTH) (TG? TF) 2 BEDROOM ;.....:........::::::. :I COURTYARD ............ ..................... . is .,20 SF i sa 1 i RISER TECr E.CT i A-. 4CE RISER RISER E RISER Ems€ �� .....---::....."" ._. E TEA TDA TDB XS' 15 : .....,:.........,....:::::.......«:..:::::......m.».:::::::.:».::::: F::::.:.,::::::..::::.:::...::».:.».:.:.:::k;::.::.::::E N:N::�:::.,.::::::::.::.::»:,:::..::.::.:::::::::..:::.:::..::..::.:. ,n :.:,::,:..:::::.:,:.», n.:n.:::.:.:::.:..............::».::...,::.,,...:..:.,.,:.....,.. . .........<.. ....:.....:............... .. .: .................:r. :.........;. ....... ..... .. x .. ii f I I i' .. .... , : . f, .._. i> I 5 , 5 STANDARD ONE s` UDfO STUDIO S•-I'ANDARD ONE 'TWO BEDROOM I STANDARD I BEDROOM 1- TAN STANDARD € I; BEDROOf� CORNER ............................................................ ,kllr- 1 VIEWED FOP, 417 I �;0 421 42S r 11 PLIAI�CE WITh €: S48 SF G� SF SOD SF 548 SF , 870 SF o , A 70 NEC ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /8" = 1'-01, CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT W w 3: OW Y ry z ^ �„f w Q W OS p Y rr� 0 QH z CM N Z N 'ULTANT REGISTRATION exg- 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264"7 FAX: (206) 826.4"6 SHEET TITLE AND NUMBER 4TH FLOOR PLAN LIGHTING E3.04 H Lo N 10 o M� W to 10 O 04 O "' d- O RM I RM 502 E4.25 RM I RM 504 E4.02 RM I RM 506 E4.02 RM I RM 508 E4.09 .: J� p E.fN :F "5� E BEDROO � �,.: �;. STANDARD ONE FI, STUDIO F,i4lEST ` BEDROOM 5 STANDARD STANDARD ONE 1 2 i ....................... UL.... � l�VV ... mJ .. 84 SE Ei a0� 57 GI* 3I1 S" f — wag SF ._ .. RISER ;. --- -- - - - ----- -- --- -- --- -- - - - - - - -<> -- 600F .... .0 ... AS3 :.._ RISER » .»...... ... I I -A RISER I E RISER I RISER ' TMB S1 TJA RISER E TIB E pE AW2 TIA E :.............�E:: ».E .:.::.»...»...»»..:.E .. ........ ...... ................5 .s I 1 I< s: s , i i : ............... `I ....... i :::- '1- -:- STANDARD ONE STANDARD ONE STUDIO BEDROOM - BEDROOM - ' " STUDIO ,; STANDARD »:.».::....; LONG .................. . LONG STANDARD 503 309 SF 571 SF 571 SF 310 SF T i (TM; RM I RM 501 E4.01 RM I RM 510 E4.09 GENERAL NOTES 1. REFER TO E7.06 FOR BRANCH CIRCUITING OF APARTMENT WING RISER CIRCUITS. 2. REFER TO E7.07 FOR BRANCH CIRCUITING OF HOTEL WING RISER CIRCUITS. 3. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. PLAN NOTES ( OCCUPANCY SENSOR SHALL BE SET AS AUTO ON. RM 502Km ouo A HR4B-2 QUEEN QUEEN I''` " A HR4B-1 ACCESSIBLE E5 01 QUEEN QUEEN :SER . ' 12 ARC ......-......... . ......... 236 SF r- - -- ------ - -- --- ........ ............... ---- -_- - -- -- ------------ - -- -- HR3 ; T8 T9A: { .� E ' 1 RISER I.I oC TCA'...................................... I HS1 E u� E 154 SF ................ I RM RM 503 I RM RM 505 I RM RM 507 I RM RM 509 RM RM 511 I RM RM 513 I RM RM 515 I RM RM 517 RM RM 519 I RM RM 521 I RM RM 523 E4.09 E4.08 E4.08 E4.09 E4.09 E4.08 E4.08 E4.09 E4.09 E4.08 E4.04 ;TJ/ i TI (TH; (TG) tTF) (TE/ (TD; (TC) TA.6 5TH FLOOR PLAN LIGHTING ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = V-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 0L w 3: O w a3: w� o > p Y r� V Q FF-- z M N N v) SULTANT REGISTRATION 15 ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 I SHEET TITLE AND NUMBER I 5TH FLOOR PLAN LIGHTING E3.05 GENERAL NOTES 1. REFER TO E7.06 FOR BRANCH CIRCUITING OF APARTMENT WING RISER CIRCUITS. 2. REFER TO E7.07 FOR BRANCH CIRCUITING OF HOTEL WING RISER CIRCUITS. 3. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. PLAN NOTES (D OCCUPANCY SENSOR SHALL BE SET AS AUTO ON. RM I RM 602 E4.25 ........... .......................... . . ....... ......................... ONE BEDROOM WEST ...................... 602 484 SF . .......... . .... . .... ............. ............... ............. ....... . ....... ............. FIRE 'E" Pll-lC RISER -__j TM A RISER T B a--,- ........... m: .... �111:�,,��l ... ................. . ............ . ........... .............. .. ........ STUDIO STUDIO WEST STANDARD 80` COS 338 SF 309 3F S,IH;. _ . ...... . RM 1. RM 601 RM I RM 603 I RM I RM 605 I RM I RM 607 I RM I RM 609 RM I RM 611 RM I RM 613 I RM I RM 615 RM I RM 617 E4.01 E4.09 E4.08 E4-08 E4.09 E4.09 E4.08 E4.08 E4.09 ITM TJ TI f% TH (TG) rTF) (TE) RISER RTSER E RISER E 154 SF TEATDB A. .... . Ef .............. ........................ .... ....... . ............... ................ ............... ........... . . ........... i. ................... ........ ....... ..................... . ......... . ............ STANDARD ONE TWO BEDROOM STUDIO BEDROOM- STANDARD I LONG .... ......... ..... CORNER .............. .. . ............ .... ...... 619 "M 621 623 .................................... 309 SF 571 SF 892 SF :M . .................. . ......... .. .. ... ........... .................................... . . ................................ .................... ................ . . . . . ........................ . ............ ............ ........... ................. .......... ...... ......... . RM RM 619 I RM RM 621] I RM RM 623 E4.09 E4,08 E4,04 TDi c� TI3 TA.6 5 6TH FLOOR PLAN LIGHTING 1�1 i -rl=, iv 0-1 I RE/lEWED-FOR CO M 3LIANCE WITH "T NffW70-- N-EC— EC 0 3 2015 —city of TukWila BUILDING DIVISION i RECEIVED �TA,l CITY OF TUKWILA OCT 15 2015 PERMIT CENTER A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB ISSUE KEYPLAN ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry w 3: 0 LLJ z �� 0 Lij > - 0 3: (D Z:D < F— z c1l) N —r N U) SULTANT REGISTRATION 5 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 I SHEET TITLE AND NUMBER I 6TH FLOOR PLAN LIGHTING E3.06 1 RM RM 702 E4.25 RM RM 704 E4.02 RM RM 706 I RM RM 708 E4.02 E4.09 RM RM 710 E4.09 RM RM 712 E4.02 GENERAL NOTES 1. REFER TO E7.06 FOR BRANCH CIRCUITING OF APARTMENT WING RISER CIRCUITS. 2. REFER TO E7.07 FOR BRANCH CIRCUITING OF HOTEL WING RISER CIRCUITS. 3. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. PLAN NOTES O1 OCCUPANCY SENSOR SHALL BE SET AS AUTO ON. IRMI RM 718 1 t ::.............................. }:. t. t.... ................. . f�ING .,_............................. .....»».i;,k; :: "CHUTE s..,;. STANDARD ELEV 2 » 0 ; •.: ELEV 03 ELEV 06 ELEV 05 — — — ..................7 J3H t:tk. t :: :: t..t..t� : , j..................:. i .; .. .. ,. f i t t :: 5 '.::::.:.::..: :.:::::::.. .. ;t BEDROOM STANI��RIO£3iE STANDARD ONE 3.JFbVl,73ti't .. '7 . :'t. tti ' I t :5 ::: F 01�E BE STUDIO _....-.... ;.. ;: > TUL EO »:..:» TANDARD ONE :: » .., , :: », S S .. .. .. , , .. , : j « • ,,.- RISER � . I t wti•^C'+^C .. .. 3 2'4 P'3"`S t�TY-A Y'AAR .. :. z i3f=ilia Y't YiFtR .. nv n w<r•.-xrtit ....... .. .. .....-....... , , ..-.......--... ... ..... .. i .. !°. ��LSRS1Ls� ,. e, -- .......... ,.-.- ...., .. .:..v:::.......... .-..-...,.,.....::.»»...,. ».:.:»: r\ .. ... .. ...: ro: :,.»: .. ........ ,, w ».'�/�... t .. S ................. ; F � STUDIO WEST # 7 f01 338 SE ..., piny!/.:V.tm::xii,J.u,,.l. RM RM 701 E4.01 iTMI E EEC..» 1r/1 IGl1 ivn ivu EZ»+ »E.. :... ............... ............... .,ET »E7,,,:,.,»...,,,:...»,..,:,,, I... �. I 5: IG il} I, I .. t: i i , , 'v: '.... ii i + ' t - .. v y i .. .. ,. .. .: y •: t t s . 1,i y -. . : .. .. : .l .. t i .. y t y § STANDARD ONE STANDARD OIE[Iw STANDARD ONE' STANDARD ON STANDARD tJNE STUDI3 5 > BEDROOM '- :: BEDROO M - STUDIO STUDIO :: BEI3R03A�i - /' BEDROOM - t STUDIO STUDIO z BEDROOM - STANDARD yt LONO :: �s .. LONG :. , , a�'Tr'�NDARIO ... STANDARD . , LCiNG utrSHA1=T .. t :;....::::::....:.::,..., �,. LONG :; . + � STAPZlE3AF:D STANDARD t ;�; ....-; LONG ((( ( 703 y�r : k t jj :: 05 :: ,: :.: .................................... 707 ;�: # :t t t. p ,. E I#0 r E} s d11 ;�; ' "%� ... 0 -.717l19 :� i15 ......... 721 30D BF t s 571 SE $ 570 SE a }1 C 3 >~E 30,. S E 51 1 {{++ 310 SE E I% T SE a 1 k i ............: ..... ...:... ..... ..:.................:.i S ' ..:......................................... ... ...................................:.:...... ... : . ................ 5• ....................... .,..v.:. ............ ....» .,. . ...... ..+. .. .+:.....-.... .......,5.. i ......... ....... -. ............................... 1 ..... .. ..._ ..... ..... .. ... .... - ................... ...... ........ ......... .............................. .. .. ...................... .- . ... .. ............. ...................... .. - oT RISER........................................................�.. � TCA> E HS1 :t 5y 154 SF XSYI ......... »,.. ».» ». ».,...,.....,...' - it :S 5 i t: : ......... • •i T �'�O BOL,ROOI�9 CORNER .................................. 5 -::, r................................',... 723 9 �..2 SF .. RM RM 703 RM RM 705 RM RM 707 RM RM 709 RM RM 711 RM RM 713 RM RM 715 RM RM 717 RM RM 719 RM RM 721 RM RM 723 E4.09 E4.08 E4.08 E4.09 E4.09 E4.08 E4.08 E4.09 E4.09 E4.08 E4.04 I i i (TJ TI, (TH) (TG) �TF; ;TE (TD) ;TC, TB, TA.6 FLOOR PLAN LIGHTING „a. -0. RM 703 A HR6C-16 Ts E5.01 7 RM 701 A HR6C-10 E5.01 E�F +iS is 'Y �Y u y` �a 3 d c �g K EWE® F0 REVI p T�.y, E WIT ¢ 0 PLIANC NFPA 70 - NEC -- I--- — --- — — T9 DEC 0 3 2015 Crty of TulcWila BUILDING DIVISION I RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE 0 Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = V-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB 'LAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT LL W 3: O W Y z a� O >g r� p Y V Q F- z C14 N N v , �ULTANT REGISTRATION — - �v�t J GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER 7TH FLOOR PLAN LIGHTING E3.07 T7 — T7.9 — w 0 0 J U- 00 N 10 -o M WU) 10 ors 0 ,Ito GENERAL NOTES 1. REFER TO E7.06 FOR BRANCH CIRCUITING OF APARTMENT WING RISER CIRCUITS. 2. REFER TO E7.07 FOR BRANCH CIRCUITING OF HOTEL WING RISER CIRCUITS. 3. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. PLAN NOTES O1 OCCUPANCY SENSOR SHALL BE SET AS AUTO ON. RM I RM 802 RM I RM 804 RM RM 806 'RM RM 808 RM RM 810 RM RM 812 RM RM 818 : E4.25 E4.02 E4.02 E4.09 E4.09 E4.02 — — — ------ -- -----E4.07 ---- I i I I I I m ............................. .... ........ ......... .. . .... .................... ............... .......................... . ...... .......... .... ......_....,... .... ... .. ....... . ... .... y STUDIO STUDIO STANDARD ONE S ANDARD ONE STANDARD ONEONEBEDROOiIF WEST BEDRC33Ii1 BEIROOt�ti 5 STANDARD STANDARD - BEIRi30I� ,i ....... --.... i........... I�2 i 8I34 3U# 80 81 £ 812 ........................................................................... 48S SF E S SF 57 SF 80 SF 30I 047 SE i. 5 § 3 , c. .............. ......... %.:.:..:: 5... ,, 7 5, , 5: , is .. .v : 'S 3.. . ... ,,..:... ..................... .:.:.::.»»..:..:»..:.... R : / i{ .: .. ,. :� y y, :.�.... »..:.»a ....:. ..,. .. ...... , :.: .. ., u ASS :: , RISEREl: ».,,,.,. , _ I I RISER I» I I I. RISER TM RISER XS1 RISER RISER CORRIDOR TMB TJA E TIB THARISER 1 AW2 E TFB i RISER O `5E E AW2 RISER E TGA=- SDD TFA +t Fi E.. i,,,»µ..,_............._,....,,.,...,,...,..._.,,,_..,,:,_,----».............. _.. ,,,,,,,..,.,,._,.,.,:..,,,.,_...,,.,,,.,.,,..,,,,.,,,M...,:_»,,,_,,,.,,._,. _,,,,..,...._..,.:,...,..E,. :::::::::::.::......E,. • r .. RM I RM 801 E4.01 (TM) 1� QUEEN QUEEN R RM 805 .......... -8------#3-5H--------.......... A HR8A-1 342 SF E5.01 .................. .... . ............ ............ I I I: I 1- I II i i _. v , , , : 5 f :5. ,: v 'i , .. , : 5: -mwA ,. , ...... 5 3 i t ;• , t , : 5 fl .+ :. .. : . :: .. . 5: % :. 'J. j.. ... .. ........... ... .. .. ...................... Lv I s 0 .. .. , ^ i SS ............. . ... .. .. r is S .. , i .. .................. • r. , .. .. :: :... i .:................. i F y ., .......... :. .: F `:. ... .. .i' .. i STANDARD lE STANDARD OE : r °;. STANDARD ONE i % t STANDARD CANE ,.. STAI'�DARD ONE .............: : STUDIO BEDROOM- BEDROOM- STUDIO STUDIO BEDROOM- .......... BEDRE rf�iVl - STUDIO STUDIO BEDROOM- TWO BEDROOM ti. i `< STANDARD LONG :: L3NG i : ; , :: ,...... ONO i STAI�iDARD STAN©ARIA s LONG - N - L;I 1 STANDARD STANDARD :I; LONG v�rtSHA1 T ;I'. ;I£ I� C0 IrR ,. _ s i :. j 8(�3 ; , 80B 807 .., , :5 :: :: i 817 81 � 821... REVIEWED FOK �� �� 8{39 811 81 S 81 S � � �-•._� � �� jj� $3 ���{ /r tc jj 3J__.__...•....... s U t�l PLIAIVC E W ITI-, O 1= "1 S �310 SF 3 9 S S71 SF 306 SF �71 �I" Sr F S5 SI" 1 "P 83� S s10 SF 3Ci9 SB 1 5 _ 7 NEC ' N FPA 0 , T i :r i I^ _ i ►-» 1 1 ► 1 s:= i i,.l i, i DEC IV 0 3 2015 i City of TukWila 3UILDING DIVIS!( RECEIVED TA; CITY OF TUKWILA �1 OCT 15 2015 PERMIT CENTER DRAWN B KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: Ory w Y a3�: w w F_ o v ¢� z M N r� V ) SULTANT ISTRATION 5 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE WA 98103 PHONE: (206) 8264447 FAX: (206) 826496 SHEET TITLE AND NUMBER 8TH FLOOR PLAN LIGHTING E3.08 \ T9 _ STUDIO WEST ........ ....9........01 .----------- 338 SF RM I RM 901 E4.01 (TM) RM RM 904 RM RM 906 RM I RM 908 RM RM 910 RM I RM 912 E4.02 E4.02 E4.09 E4.09 E4.02 - I I _: , I ;...... I I ........ ........................._.,.,..._ _ ......................... _ •`� _ __ _�„ STANDARD ONE _._ ____.___.... y—._.__._ ;-: ___ __.__—__. ..___ STANDARD C E _.. .:, s—_ ; :�: _. .--- .__ STUDIQ ._may— — __ STUDIO STANDARD CITE BEDROOM BEDROOM :5 STANDARD x STANDARD BEDROOM 904906 D08 x x 91.0.. ................................. B1 ... ff .... (............................... . - Sub Sr ............... : < :; S 7 SP t 309 SF 309 BE i 547 BE RISER AW2 TIZ ...... REVIEWED FOR, COK4PLIANCE WITF6 N�PA 70 - NEC -- --- — dEC p 3 - -- �/ ?.015 I i City of-TukWila BUILDING DIVISION! i i RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE 0 Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB PLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: 0 w Y ry z ry Q O W J p� V QH z M N N r� V ) 3ULTANT REGISTRATION /15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER 9TH FLOOR PLAN LIGHTING E3.09 GENERAL NOTES 1. REFER TO E7.06 FOR BRANCH CIRCUITING OF APARTMENT WING RISER CIRCUITS. 2. REFER TO E7.07 FOR BRANCH CIRCUITING OF HOTEL WING RISER CIRCUITS. 3. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. PLAN NOTES O1 OCCUPANCY SENSOR SHALL BE SET AS AUTO ON. RM I RM 1018 ---E4.(i7 -- I ::..............:::i' 2 BEDROOM — — ............ r I .. .. : ::... .. ISE RISER , 4 E — - -- — ri99 CHW2) «.:. ::: ............................................. . .� RISER :RISER - T8A --------- - - ----- -- ------ - -- - Ts L... ...... .. . , ». ».., ,,, ....... 1€: .........:»..:.» », ....._ ,. :». .... ..,::»:,: ;: : : ;; s is i )' I: cE i- 3 - - i < E r ..• .......... ., • .......... STUDIO WEST .......................... I I 338 SF I 1001 RM RM E4.01 i (TM) STANDARD ONE1 STUDIO ;I- BEDROOM :::: STANDARD LONG :.......... TYPE A 'I TYPE A 10I1 1013 . 309 SF 551 SF i RM I RM 1011 E4.09 RM I RM 1013 E4.08 ;TG) rrw I.. — :. +a..vavv ..IA tJ ]f'YEtlL/T][i6�' Va tP'l{a[6i1"4E�V !�� a..ua,w- +w w✓a .<<a...<• ......................... ....................................... _ i Sis ;; y.................................... � s .................................... 101? 101., 1021 1023 Fl S EU FO u 'r jA c w IT P 1 2 F -71 "�' SF LSD S � SP o 3 �39 SF 10 SF q N EC 0 3 2015 v <. s.................................................. ... .................................... RM RM 1015 I RM I RM 1017 RM RM 1019 I RM I RM 1021 I RM I RM 1023 E4.08 E4.09 E4.09 E4.08 E4.04 j i TF,, tTE TDa (( B) TA.6 n 10TH FLOOR PLAN tTGHTING I Ity of -Tukwila QUILDING DIVIS`ON. RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = l'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT Q. W 3: OW Y ry IL LUQ O W J p Y V Q F=— z co c\l N � N �X V Q ;ULTANT ISTRATION 15 ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 I SHEET TITLE AND NUMBER I 10TH FLOOR PLAN LIGHTING E3.10 T ............ ...................... . ....................... . ........ ...................... ............ .................. .......... w ......................... ........... .......................... ... .......... 1-� ......... .............. ii .................. ................. ..... . ...................... . ... ....... _...IA ItIR19 --------- - - T6.1 81 51 E ELEV 03 ELEV 06 ELEV 05 LEV 02 ................. 54 SF E5.01 :s —s-rup — STANDARD- NE tO— .. —STAN - --,l I DAR0j--ONE—: T H .......... .......... ................... . .... .. .......... ------ - ----- .. . .. ... T 0 G:.: ..................... T7, ......... .. ............ ... . . .......... ........ . ..... 61AN ............ ............ OR R IEWED F ..................................... .................................... 1021 1017 1019 11 . ............................. ...... PLIANCE WITH ........... ............. i-666 i YH: A i yvit A LUNU 5TANDAR STANDARD LONG LONG STANDARD STUDIO WEST 1003 1011 co 892 SF 310 SF 309 571 SF 310 SF 309 SF 571 SF N PA70-NEO 571 571 SF 338 SF 309 SF SF SF 551 SF 0': Llr 0 3 2 015 T MM .... . ... . ......... . . ............. ............. . ......... .. ... .... .. ........... ............ ..................... .......... .......... .............................. .............. ......... . ........................ ..... ........ . . ......... . .... ...................................... .................. .............. ............. ................ .............. .......... ............. ................. .......... . ...... ............. ..................... ;.n .............................. ............... ................ .................. :- ................................. ............. ......................... . ......... . ......... ................. ................ . .......... '1,1 ....... ... ....................... .............. ....................... . . . . . . . . . . . . . . .......... ........... . ...... ....... ............ ............. ......... ........... .......... .. .. . ... ............ :� . . ... .......... ............. *,..,.. . .............City of TukWila RM RM 1101 RM RM 1103_ RM I RM 110 RM RM 1107 RM RM 1109 RM RM 1111 RM RM 1113 RM RM 1115 RM RM 1117 RM RM 1119 RM RM 1121 RM 1123 1 BUILDING DIVISION' I q I 1 4.08 1 E4,08 E4.04 E4*01 E4*09 E4,08 - E4.08 E4.09 E4.09 E E4.08 E4.09 E4.09 RECEIVED CITY OF TUKWILA TG) CT�) rTB {TM) 'T (TH) ATE; (TD) TA.6 ITS, rj11 TH FLOOR PLAN LIGHTING OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/81, = CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB EYPLAN PHASE. ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 0L w 0 Lu F— z (L 3: 0 ry - Lu < > 0 0 ::) Z < �— z ce) N c\l U) CONSULTANT REGISTRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 .FAX: (206) 826-4446 SHEET TITLE AND NUMBER 1 1TH FLOOR PLAN LIGHTING E3.11 CD z F- z a. of 0 9 u- GENERAL NOTES 1. REFER TO E7.06 FOR BRANCH CIRCUITING OF i. Tl APARTMENT VYING RISER CIRCUITS. E E 2. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. 'CF-li""ZER .................................... ..................................... RM RM 1236 E4.15 PLAN NOTES . .. ...... ... . O OCCUPANCY SENSOR SHALL BE SET AS AUTO ON. RISER T21 C 111E SEDRO"N.11 A33 3"t All i 0 3 E "4E.C'0R�NIER .............1 .... ................... 1239 .................................... RISEt T2W' 7.'Al- ER ............. T V 2 .... .............. xsl 5q2 SF RM RM 1239 E C@) E . E4.14 E r_l ...... ................. .......... .............. ..... .... . ..................... ................ S'FANDARD ONE RISER T32 S" ANDARD BED E STU= LO,,Gl "OR"I VV DE' RM RM 1234 . .................................. ... ' 1234L 237 RM RM 1237 E4.16 SF E4.12 RISER T31 .... ... ....... . .. .. . ..... . . ...... .... ........ E ......... ... ....................... .......... .......... . . ...... STANDA RD 370:0 LGNQ ................... 1235 ...................................... 360 SF RM RM 1235 . ........ .......... ............. E4.12 ......... ... --- ..... ...... ...... .... ............ - - ------ -- - -------- .... . ... .. ...... .... ........ ........ .. ... .. .. .... 'rT 3) TA9 RM I RM 1230 E4.09 RM I RM 1225 E4.11 I I ........... .............. ..... . ............................ .................................. . ...... .. .................... ......... ............. 2121221236i 113iii i1 i117 1219 1221 R EVIEWED FORb[ i COMPLIANCE WIT 893 SF 571 SF 310 SF 551 SF 571 SF 309 SF 570 SF 309 SF 310 SF 571 SF N Oil 21 !......................................... .... .................... .....................................r. .................. ....................................... ................................... .......... . ........ ............................I ................ ........ ..... ............ ... .. I . . ......... - ------ ..................................................... .................................................... . ... ..... ............. . ....... ............................ . ...... ......... ........... .............................. ........ 11=11-1-l�1-1.111,,. L. .=..."..,.".".. ",-". ""-I ..........111111=1_1 .... ...................... . I. . . ............................ .............................. ..................................... ............... ........... .. ..................... . ...................................... ........................ ................. ...... . . . ................... ...........� ..... . .. .. . ..... . .. .... .......... 201503 . ffi ........... RM Cfty, of -TukWila 221 RM RM 1207 RM RM 1209 RM RM 1 RM RM 1 RM lq M RM RM 1 RM RM 11213] RM RM 1219 RM RM 1221 RM 1223 BUILDING DIVISIO, E4.08 E4.08 E4.09 E4.09 E4.08 E4.08 E4.09 E4.09 E4.08 E4.04 RECEIVED CITY OF TUKWILA TA.6 TI (TH (TG 1 (TIF (TE-) (TD c') TI3 (TA rT �'Tj/ 12TH FLOOR Pt AN LIGHTING OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = l'-O" CHECKED BY. CHL APPROVED BY: DRAWN BY: JAB (EYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT w w 3: 0 Lu F- z CL 3: Of - < 0 F- UJI > I 0�0 Z < z cf) (N 04 U) CONSULTANT REGISTRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826-4446 SHEET TIRE AND NUMBER 12TH FLOOR PLAN LIGHTING E3.12 z IL w 0 0 9 u- CN 10 oN, GENERAL NOTES 1. REFER TO E7.06 FOR BRANCH CIRCUITING OF APARTMENT WING RISER CIRCUITS. 2. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. PLAN NOTES (D OCCUPANCY SENSOR SHALL BE SET AS AUTO ON. RM I RM 1,30 RM RM 1E4.02 E4.02 E4.09 E4.09 E4.02 ,304 RM -RM 1,306 RM RM 1,308 RM RM 1,310 RM RM 1,312 RM RM 1,318 E4.25 .07- - ............... .... . . ...... ........ ........ ONE BEDR00,10 W.EST .................... .. ----- ----- -------- - - 483 SF . ......... Ll FO 1300R. ..... . .... — RISER TMZ RISER XSl E TMY E C I ............. .. ................ STUDIO WEST 1301 338 SF T9� .... ...... ?� ............. ............... RM RM 1,30 E4.01 1 f TM: AW2 RISER TIZ H. 2 BEDROOM DENvviSHAFT ...........-� ii� 883 SF RM I RM 11,313 E4.10 .......... .......... 2BEDROOM DEN - ----- - - - 1315--- 904 SF RM I RM 131 E4.10 (TF) (TE) .. . ......... RM I RM 13,32 E4.13 RM I RM 13,30 E4.09 2BEDROOM DEN TYPE A .......... ........... 904 SF RM I RM 1319 E4.10 (TD) 1--� RM I RM 1 E4.041 rTC) TB) TA.6 13TH FLOOR PLAN LIGHTING 135VIEWED FOR COMPLIANCE WITF, T NFPK70-- NEG- I DEC 0 3 2015 qdy of TukWila BUILDING DIVISION RECEIVED CITY OF TUKWILA (TA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8"= V-0" CHECKED BY: CHL DRAWN B KEYPLAN APPROV PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT L.L. w 0 w F- V z CL 0 Q� w > 03::) Z z cy) C14 04 U) 'ULTANT STRATION ONALL 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-446 SHEET TITLE AND NUMBER 13TH FLOOR PLAN LIGHTING E3.13 �9 - F- N 1 O 0 GENERAL NOTES 1. REFER TO E7.06 FOR BRANCH CIRCUITING OF APARTMENT WING RISER CIRCUITS. 2. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. PLAN NOTES 0OCCUPANCY SENSOR SHALL BE SET AS AUTO ON. RM I RM 1406 E4.02 i Rm RM I `tV 1 I Rm Rm 1` i I RIn Rm I `W / I Itm rNm 1 Y 1 J I ttm RM 1 -t 1 J I j I E4.01 ! E4.10 E4.10 E4.10 i E4.10 iTMI TJ� TI iT ) ;TG; TF ;TES TD) RM I RM 1439 E4.14 - - - T2) RM I RM 1437 E4.12 RM I RM 1435 E4.12 -- - - T3 RM I RM 1433 E4.13 € STANDARD 'oE STUDIOVWS _ AFT RM 1 .......................... ......RM U ... - ........................ _...::............. .. 14-31 RM RM 1431 E4.09 327 SF ? 3c"s SF E4.09 RISER T51 t I E _ ....:.. ....._. STU010 S T ANi #ARD STANDARDI STUDIO RM .... ! 1428 ..... a ..;. z ,;;: AE- RM 1428 i a i�;20 I T RM RM 1429 E4.09 32�i' SF _ ........ .....- wu SF E4.09 i ! TB. i RM RM 1423 E4.0 I 4 i 4TH L R PLAN -LIGHTING T" 1F 00 G — T6 T6.1 u ---------(T7) I REVIEWED FG POMPLIANCE WI"# NFPA 70 NEC -- T9 1 DEC 0 3 2015 W H O.. ISION RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /8" = V-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT No W 3: O W `1 Ili o W J pY V Q I=— z M N T� N VJ CONSULTANT GISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826.4447 FAX: (206) 8264446 SHEET TITLE AND NUMBER 14TH FLOOR PLAN LIGHTING E3.14 rn 3 Z J z J IL Of 0 0 INm I r-'m I aU I I r-'m 1 RM I UUJ I KM KM IOU/ I I KM I KM 1011 E4.01 E4.10 E4.10 E4.10 (TM : TJ) t TI TH) ;TG! (TF) .� � 1� TB.9 i TB.1 i I TA j GENERAL NOTES 1. REFER TO E7.06 FOR BRANCH CIRCUITING OF - APARTMENT WING RISER CIRCUITS. T1 T1 2. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. �s ; .......... .............. s..`...........: RM RM 1536 PLAN NOTES E4.15 O1 OCCUPANCY SENSOR SHALL BE SET AS AUTO ON. RISER 4 D ..�� AS3 S s- 0 00 J !. I , .. '�OR" E i............... .' r E i--'L 3J RISE � ER , OD2 SF T211'.. T2V rl XS1 RM RM 1539 I I E4.14 E. E rE" - -- !'. - ; T2 STAil DARD ONE I RISER L D fZGLY<f� T32 STANDARD ..'i... �'e �Y3EFs:%DE.-Ni . F,,� = ....... i.. E y �J i'..�.J`�E..t✓',3 ' 1 �1 RM RM 1534 ' ` ' —� - W RM RM 1537 E4.16 E4.12 RISER T31 is E�' I STAND RD �'i": Et':vG ,-:�0 L0 RM I RM 1515 E4.10 RM I RM 1533 E4.13 A..................i 130 I 'NiSHA I RM RM 1530 .. ..... . ... RM RM 1531 E4.09 354 SF E4.09 i RISER 1 f :.. i - r• _ STUDIO I SEANDARD STANDARD -. STUDIO ..... ..................: .... .......... _28 .: .:..: .: �1�1f�' FT RM RM 1528 -...........3 ° .`--2 -_ ---'' �........._� RM RM 1529 E4.09 327 SE .................... i f 35-4 SF E4.09 _._. _ [ A, ....... _ . T5 REVIEWED F0I`1. ,OMLIANCE WIT'l '- N 'PA70-NFr, E � Tukwila DIVIS10 � I • .•. • E4.10, ..... • _... E4.04 v I RECEIVED CITY OF TUKWILA (TD; t TC � TB) TA.6 OCT 1 5 2015 15TH FLOOR -PLAN LIGHTING ,�8•=,-0• PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /8" = 1'-0'- CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W O `Lu S Q Q �g� CL Of W J F— pY V Q F— z M N T�� L N r.A V ) CONSULTANT REGISTRATION •r'; � yn'r,r•i GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER 15TH FLOOR PLAN LIGHTING E3.15 3 Z J Z J a m 0 0 62 GENERAL NOTES 1. REFER TO E7.06 FOR BRANCH CIRCUITING OF APARTMENT WING RISER CIRCUITS. ,!' 2. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. PLAN NOTES O1 OCCUPANCY SENSOR SHALL BE SET AS AUTO ON. RM I RM 1636 E4.15 t ITM! �TJ TI; (TH) iTG) ITF (TE) STD) ;TCI (TBi TA.6 1 16TH FLOOR PLAN LIGHTING v8" = r-0" RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT LL W 3: O W z 04.. O w Q J p Y V Q N z cN N N �♦Z VJ CONSULTANT REGISTRATION /15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826A447 FAX: (206) 826.4446 SHEET TITLE AND NUMBER 16TH FLOOR PLAN LIGHTING E3.16 RM RM 1702 RM I RM 1704 RM RM 1706 E4.25 E4.02 E4.02 I ............................. _ .. ..... :......._,..........x.:....... I _ ».. I ........... t ........................... • i:f t .t, ONE BEDR£3E3td1 t _ €STANDARD 0€Iq ft STANDARD ONE -WEST .., _. ...... BEDROOMBEDRE3€ i if f ' M ::. f 1i02f ..... . 17TH FLR `f 1 r; H FLR. 463 SF 1 04 �._ ff 7 1 0� VSFJ' t f 5S3 S�-47I" , t : f , : 3 t N 10 0 TB.9 TB.1 rTA i I GENERAL NOTES i j 1. REFER TO E7.06 FOR BRANCH CIRCUITING OF APARTMENT WING RISER CIRCUITS. TI ; _ _ __ __ ; T1 ; 2. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. rr C-OR.N"ER - TrH t ._i' RM RM 1736 PLAN NOTES _. E4.15 O OCCUPANCY SENSOR SHALL BE SET AS AUTO ON. 1. RISER : <D�EBEI3Rwt,=..1 _: T21 J......... t ,t, ," _. AS3 . ,aIR 003 f` j RI T G3 RISER ;392 3F T2W T2V RM RM 1 739 i I E4.14 E - E I - NE 6EDROOM RISER T32 5-�LL;3€3 C� : Ti FLR E �? �O ................................... L. "TH d .. 3 RM RM 1734 —Fi.. SLR RM RM 1737 E4.16 F 7:z7 E4.09 RISER :- 3 7 c�. T31 _. : ,. .,. S :".A I Rh ....:; NORTH -: �— 1735 RM RM 1735 ... t �.. . -27 SF E4.09 f is RISER T42 i E awz ! I i... ........ ............ ...... I....................................... ...... ....... ................................. E BEDROOM .. ...........: { ................... ......... ............ ......... ........................................ ...... ONE BEDROOM ' 1 ST;'�i' DARD �. STANDARD NORTH: 17TH NORTH 17TH FLR . l FLR RM RM 1732 1732 .........._i Ia3.......... RM RM 1733 E4.13 ! 578 SE I ----- .. 579 BF E4.13 RM I RM RM 1712 RM RM 1718 RM RM 1710 E E4.09 E4.02 --- --_ — ---- -- --- 4:07-�.::::.�'........... ».x. r170.8 ............... ..... ... ... ...,. .. .. _. .... ....................... ...._. .. _... ............ ... . __. ,.... ..................._... __.. .. .. is S'i'Ui33O S1'UL3fO BTANDARIs OidE 1 - I BErJR03M STANDARD STANDARD>� BEDROOM ;f i% CCOURTYARDURTYARCOURTYARD17TH FLR 1 aTH FLR : ,; 17TH FLR t. S 17 TH FLR ` .. 17 0z �i 171.,cl f 17.g 9 z. 1718 ............ 309 SF ; 309 SF 547 SF 918 SF : : f y: : . ................. .:. .......... y, i : RISER ....... , t .: :. t TEX t EL—C "T. .........: ' t : : t• '• f............_<. f 17Us'.IF .............. t i :............:., t i I RISER AW2 -0� TFZ I TF; .................... __...._......................,....................................... ........... ..... ...........I................. .f ft y ........................................... EL 0 99q ..... , 13 1; I j: t3 i..... ........ f t: 'P010 BEDROOM CORNER 17TH FLR _.. .i ........... ...-- ................ _:....................................... »:.::... ,.».x.:::. »::.:..xn»» ...:..w:».... y 869 SF ».. : f..j:.::.::. :w :::.; R• VIEWED FOR PL F - TAN IT yz IFPA 70 -NEC — — — — — — T9 ..... 'DEC 0 3 2015 I . _. »_......:----_..............._.....».. ...............................................................................................................................................................................: MY of-Tt,rkWila SU' RM RM 1723 I I DING DIVISION E4.04 j I ! ! RECEIVED (Tc) TB, T 6 TA, CITE' OF TUKWILA 1 1�TH+FLOOR PLAN LIGHTING" OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8" = V-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB PLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT w w 3: OW Y ry z d� o wQ W J F— pl (D aF- z M N -17 N V ISULTANT 31STRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 - PHONE: (206) 8264447 FAX: (206) 826-4446 I SHEET TITLE AND NUMBER I 17TH FLOOR PLAN LIGHTING E3.17 CT7 1--� T6.9 TBA (TAI GENERAL NOTES 1. REFER TO E7.06 FOR BRANCH CIRCUITING OF Tl, APARTMENT WING RISER CIRCUITS. Tl! 2. PROVIDE #10 CU FOR ALL GENERATOR CIRCUITS. PLAN NOTES O OCCUPANCY SENSOR SHALL BE SET AS AUTO ON. a; N 0 R T 1 RM RM 1839 E4.23 1790 Sl- AS3 TAII�R .0 , 03� .......... RISER[ 3ER T V. '7� 2 . ...... 84 . ....... E ' . .............. r� "J" . . ....... . .. ...... ---(T2; ... . . .... .............. .... . ............ ().RISER' ....... .......... ........... 18N i ........ STANIOARD ONE ............... ....... RM RM 1842 NN OR T H W Cq EN E4.16 .................................... p 842 RISER 180 ..... . ..... - E .. .... ... . .. .......... .. q . . .............. .... .............. ..................... ...... ... . RISER ............... . . ........ .................. . . ........ ... 18Q E+ ------ ----- -- - -------------- ..... ...... ... .. ... - ------ . .... ........ . . ... ..... . . .......... ... ............. .... .. . ---------- . .......... RISER . ................... 18R ....... . ..... I—" T7.9 5o'n ............ ........... st . IEWEDO�- 1823 PL P7QC- E Wl1828SF 1789SF17F69 SNECA Tq) K T 0— EL 0 3 2015 iN ....................... . ... ............. ............ .................. .......... ....................... .. ............................. .. ............. ......................... .................. ..................................................................... .......... ......... ................................... ................. .............. ............. ................. ......................... ........... . ......... ................... - --- -- I ........... ........ . ... ........................ ........... ............................................................... ............ 11 ............................................................. ... .... ..... ............................... ....... . ............................ . ............ ..... . ........................................ ..... .. , M-1, ........... L I I", *. '.* =,7' - -- . -.1 1 ........... .................. . ........ ............ . .... . . .. RM RM 1 RM RM 1809 I RM RM 1819 RIM RM 1823 1 1 1 1 BUILDING DIVIS" E4.19 E4.20 I E4.24 E4.04 RECEIVED TD TC) (TA) CI I Y OF TUKWILA Ti TI (T�H) (TG) TE TB TA.6 f TM) (T�F 18TH FLOOR PLAN LIGHTING OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/8"= 1*4' CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry LLJ 3: 0 LLJ F- z CL 3: 0 - w< LLI > j 03: Z::) < z CIO 04 04 U) CONSULTANT E-GISTRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER 18TH FLOOR PLAN LIGHTING E3.18 (T9 z LIGHTING CONTROL ZONE LEGEND: r-- — - — - — - — ---- PRIMARY DAYLIGHT ZONE L SECONDARY DAYLIGHT ZONE 19TH FLOOR MEZZANINE - ELEVATOR MACHINE ROOM LIGHTING PLAN 1/4' = V-0" a : J� : ................................................. ........................................ . ..... . ........................ .............. ............. t-�lw oT- i umia ... ................................. .................. ...... ............... ....... ...................... ............ ................................................. . . ...... .... ... .. ...................... .. .... ... ... ...... ........ ............ ...... ... ... ............. ....................... .. ................... .... .. ... . ............. .......... BUILDING DIVISir RECEIVED CITY OF TUKWILA (TM I Ti T1 NTH) 'TG) (TF T TE TD) c TB; TA.6 TA) LOUNGE'PtAN LIGHTING OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry ui 3: 0 w F- Q Q z CL 3: 0 X':� w _j > - F- 03: a v (D Z:D < z cy) U) CONSULTANT H-GISTRATION 15 Emmom ----------------------------- - -- - ----------- - GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 8264U6 SHEET TITLE AND NUMBER LOUNGE PLAN LIGHTING E3.19 E31 W 0 0 0 Q 0 Z Q N N 0 0 a PANEL Sl BR LOCATION: STANDARD 1-BEDROOM UNITS SERVING: APARTMENTUNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 BATHROOM RECEPTACLE D 0.000 20/1 A *20/1 0.000 D DISHWASHER 6 7 WASHER/LAUNDf Y D 0.000 *20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 DRYER - D - 0.000 - 20/2 - A 40/2 - 0.000 - D - RANGE - 10 11 B 12 13 HEATING - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPARE 16 17 SPARE S - 20/1 A 15/2 - 0.000 - M - WSHP (WATER SOURCE HEAT PUMP) (UNITS # 1804 & 1806 ONLY) 18 19 SPARE S - 2011 B 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH H M D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. 0 Q 0 Z V) N N O 0 N 4 w In o, 0 3N v O \ � J O � L� c- n STANDARD ONE BEDROOM 1/4^ =, '-o• STANDARD ONE BEDROOM 2ND FLR 205 5552-S11 I STANDARD ONE BEDROOM RCP v4• = r-0• GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A, AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. PLAN NOTES O1 PROVIDE MOTOR -RATED SWITCH, RACEWAY/CONDUCTORS, AND CONNECTIONS AS REQUIRED TO WATER SOURCE HEAT PUMP FOR LEVEL 18 APARTMENT UNITS # 1804 AND 1806. REVIEWE OR COMPLIANCE NFPA 70 o NEC DEC 0 3 2015 City of-TuWila 'I BUILDING DIVISION _' RECEIVED CITY OF TUKWILA OCT 115 2015 PERMIT CENTER ISSUE a Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/4" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB CEYPLAN PHASE i ELECTRICAL PERMIT I PROJECT NUMBER GWA NO. PROJECT 1.� W W Y ry z a� O wQ W J � pY �./ Q F— z M tV N rr� VJ CONSULTANT REGISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 8264446 SHEET TITLE AND NUMBER STANDARD ONE BEDROOM PLOTTED: E4.02 PANEL SS2 LOCATION: STUDIO STANDARD - 2ND FLR UNITS SERVING: APARTMENT UNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 OA00 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 BATHROOM RECEPTACLE D 0.000 20/1 A *20/1 0.000 D DISHWASHER 6 7 WASHER/LAUNDRY D 0.000 *20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 DRYER - D - 0.000 - 20/2 - A 40/2 - 0.000 - D - RANGE - 10 11 B 12 13 HEATING - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPARE 16 17 SPARE S - 20/1 A 20/1 - S SPARE 18 19 SPARE S - 20/1 B 20/1 - S SPARE 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH H M D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. 0 Z N i 0 af a 0 Z 0 T9 Is amw i ;TH) STUDIO STANDARD - 2ND FLR. 1 /4' = T-0" (T9 -- - TH) 6 STANDARD STUDIO - 2ND FLR. RCP v4. = V-0" GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-468-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. REVIEWED .FOIE COMPLIANCE WIT% NFPA 70 - NEC DEC 0 3 2015 City of-TukWila BUILDING DIVISlM RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/4" = l'-O" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: O w Y tY D- W J F_ pY V QH z CM N TT� N ♦1 V ) CONSULTANT REGISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER STUDIO STANDARD- 2ND FLOOR PLOTTED: E4.03 PANEL 2BRC LOCATION: 2-BEDROOM CORNER UNITS SERVING: APARTMENT UNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 125 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D DISHWASHER 6 7 BATHROOM RECEPTACLE D 0.000 20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 WASHER/LAUNDRY D 0.000 *20/1 A 40/2 - 0.000 - D - RANGE - 10 11 SPACE S - - B 12 13 DRYER - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPACE 16 17 HEATER *** (NOTE 3) - D - 0.000 - 20/2 - A 20/2 - 0.000 - D - HEATER *** (NOTE 4) - 18 19 B 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 KVA 0.01 AMP CALC. LOAD 0.00 0.00 KVA 0.01 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. 3.) PROVIDE (2) 2011 BREAKERS AND LABEL AS 'SPARE FOR APARTMENT UNIT #1823 ONLY. 4.) PROVIDE (1) 25/2 BREAKER AND LABEL AS 'WSHP (WATER SOURCE HEAT PUMP)' FOR APARTMENT UNIT #1823 ONLY. Cn 3 v uj W z 0 U 0 0 o: 0 W m GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. PLAN NOTES 1O PROVIDE MOTOR —RATED SWITCH, RACEWAY/CONDUCTORS, AND CONNECTIONS AS REQUIRED TO WATER SOURCE HEAT PUMP FOR LEVEL 18 APARTMENT UNIT # 1823. TC ; i i i TS j TA.6 TWO BEDROOM CORNER 1/4' = V-0" TWO BEDROOM CORNER RCP RECEIVED 1/4•=r-0• CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /4" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE S PERMIT PROJECT NUMBER GWA NO. PROJECT L!� W 3 O w F Y z D- w Q W J p Y V Q F— z M N T� N rr.��1� VJ CONSULTANT REGISTRATION v sl01YAL E�'`(�, 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER TWO BEDROOM CORNER E4.04 PANEL i BRG LOCATION: 1-BEDROOM GARDEN UNITS SERVING- APARTMENTUNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 BATHROOM RECEPTACLE D 0.000 20/1 A *20/1 0.000 D DISHWASHER 6 7 WASHER/LAUNDRY D 0.000 *20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 DRYER - D - 0.000 - 20/2 - A 40/2 - 0.000 - D - RANGE - 10 11 B 12 13 HEATING D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 151- B 20/1 - S SPARE 16 17 SPARE S - 20/1 A 20/1 - S SPARE 18 19 SPARE S - 20/1 B 20/1 - S SPARE 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. 0 M Z w 0 a 0 0 0 0 w m a ONE BEDROOM GARDEN - 3RD FLR. ONE BEDROOM GARDEN - 3RD FLOOR RCP 1/4" =1'-0' i i TE) TE/ T6, T6.1 -----------------t T8 GENERAL NOTE: 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-468-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-4-68-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. REVIEWED FOB. COMPLIANCE WI l'. NFPA 70 a NEC DEC 0 3 2015 1 City of -Tukwila BUILDING DIVISIO�l RECEIVED CITE( OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /4" = l'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT LL! 3: O W Y T a. 3: O w Q W J pY V Q H z M N T� N ♦1 V ) CONSULTANT REGISTRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER ONE BEDROOM GARDEN 3RD FLR E4.05 PANEL Sw+ LOCATION: STUDIO WEST PLUS UNITS SERVING: APARTMENT UNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 BATHROOM RECEPTACLE D 0.000 20/1 A *20/1 0.000 D DISHWASHER 6 7 WASHER/LAUNDRY D 0.000 *20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 DRYER - D - 0.000 - 20/2 - A 40/2 - 0.000 - D - RANGE - 10 11 B 12 13 HEATING - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPARE 16 17 SPARE S - 20/1 A 20/1 - S SPARE 18 19 SPARE S - 20/1 B 20/1 - S SPARE 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. 3 0 0 V) U) 3 0 0 0 W m W- Z 0 N 10 o -4 W N f0 0 0 It 0 _.. ..................... . n FIRE ALARM I ITM; TJ) STUDIO WEST PLUS 1/4• = 1'-0' GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-4613-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 4-06.11 AND WAC 296-46B-406. - ( T7 : r� T7.9 68, ..... __: .............................. .......................... I .... ............ .......... ................ ............................. ..... ....... ...... ..... ....................... ...... ..... ....... ...... ..... ............ ............... ....... ............ ............................ 5 f................................... .. ......... ....... .. STUDIO WEST PLUS 3RD FLR 302 , ... ... s ..:.. .....:.......:..:.:...:::..:::.. • f : .. ::. € € GWB-01 . € . • ;€ ....:...: FIRE.ALARM • • 3dOF T_ Ii IN, $......................................................... i I (TM) (—Ti) 6 STUDIO WEST PLUS RCP 1/4'=VO' n- -ttiVl WED F .,OMPLIANCE W) " UtL 0 3 7015 •..olviSt 7 +la ILDIN RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE © Date Description 10/ 07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/4" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT reo W 0 w Y 0- 0 w Q W J pY 0 Q z cI— M N N VJ CONSULTANT REGISTRATION 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER STUDIO WEST PLUS E4.06 PANEL 2BRYD LOCATION: 2-BEDROOM COURTYARD UNITS SERVING: APARTMENTUNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 125 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D DISHWASHER 6 7 BATHROOM RECEPTACLE D 0.000 20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 WASHERILAUNDRY D 0.000 *20/1 A 40/2 - 0.000 - D - RANGE - 10 11 SPACE S - - B 12 13 DRYER - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPACE 16 17 HEATER *** (NOTE 3) - D - 0.000 - 20/2 - A 20/2 - 0.000 - D - HEATER *** (NOTE 4) - 18 19 B 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. 3.) PROVIDE (2) 20/1 BREAKERS AND LABEL AS 'SPARE FOR APARTMENT UNIT #1818 ONLY. 4.) PROVIDE (1) 15/2 BREAKER AND LABEL AS'WSHP (WATER SOURCE HEAT PUMP)' FOR APARTMENT UNIT #1818 ONLY. ac�se�1 TWO BEDROOM COURTYARD 1/4" = V-0• GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-468-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. PLAN NOTES O1 PROVIDE MOTOR -RATED SWITCH, RACEWAY/CONDUCTORS, AND CONNECTIONS AS REQUIRED TO WATER SOURCE HEAT PUMP FOR LEVEL 18 APARTMENT UNIT # 1818. ;.. T7.9 11---\ -- T8 1 ----T6.1 T1 3EVIEWED FOR )MPLIANCE WITH NFPA 70 - NEC DEC 0 3 2015 City of- T'ukWila BUILDING_ DIVISION RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/4" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB CEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: O W Y z a� © � Q W J pY V Q :D z M N N V ) CONSULTANT REGISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER TWO BEDROOM COURTYARD PLOTTED:3/5/201510:38:18 AM PANEL S1 BRL LOCATION: STANDARD 1-BEDROOM LONG UNITS SERVING: APARTMENTUNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 BATHROOM RECEPTACLE D 0.000 20/1 A *20/1 0.000 D DISHWASHER 6 7 WASHER/LAUNDRY D 0.000 `20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 DRYER - D - 0.000 - 20/2 - A 40/2 - 0.000 - D - RANGE - 10 11 B 12 13 HEATING - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPARE 16 17 SPARE S - 20/1 A 20/1 - S SPARE 18 19 SPARE S - 20/1 B 20/1 - S SPARE 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. n STANDARD ONE BEDROOM LONG 1/4' = V-0" TtT99 ,---- -- 6 STANDARD ONE BEDROOM LONG RCP 1/4- = T-0- GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCA11ON WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. I ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC DEC 0 3 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/4" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT i W 3: O LU Y !Y 0- oW� pY V Q I— z CM N N U) Q CONSULTANT REGISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER STANDARD ONE BEDROOM LONG • PLOTTED: 3/5/201510:38:50 AM PANEL SS LOCATION: STANDARD STUDIO UNITS SERVING: APARTMENT UNITS FED FROM: METER CENTERS (SEE ONE -LINES) It 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B 20/1 0.000 D KITCHEN APPLIANCE 4 5 BATHROOM RECEPTACLE D 0.000 20/1 A 2011 0.000 D DISHWASHER 6 7 WASHER/LAUNDRY D 0.000 20/1 B 20/1 0.000 D GARBAGE DISPOSAL 8 9 DRYER - D - 0.000 - 20/2 - A 40/2 - 0.000 - D - RANGE - 10 11 B 12 13 HEATING - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPARE 16 17 SPARE S - 20/1 A 20/1 - S SPARE 18 19 SPARE S - 20/1 B 20/1 - S SPARE 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. 3 T9 WH STANDARD STUDIO v4• = r-0• T9 , 2 STANDARD STUDIO RCP v4' = r-0• GENE L NOT S 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. 4. SEE FLOOR PLAN FOR SPARE CONDUIT FOR FUTURE A/C UNIT TO ACCOMMODATE HOTEL OCCUPANCY ON LEVEL 12 AND 13. z "OE PL AINCE WITH FOR OI IrPA 70 - NEC I ULU 0 3 2015 City ila BUILDING DIVISION. RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE STANDARD STUDIO v4• = r-0• T9 , 2 STANDARD STUDIO RCP v4' = r-0• GENE L NOT S 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. 4. SEE FLOOR PLAN FOR SPARE CONDUIT FOR FUTURE A/C UNIT TO ACCOMMODATE HOTEL OCCUPANCY ON LEVEL 12 AND 13. z "OE PL AINCE WITH FOR OI IrPA 70 - NEC I ULU 0 3 2015 City ila BUILDING DIVISION. RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE 0 Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /4" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT LL w 3: 0 w Q Q ry Q W J F_ pY 0 z Q t-- M _r N N rr VJ CONSULTANT REGISTRATION /15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER STANDARD STUDIO E4.09 PANEL 2BRD LOCATION: 2-BEDROOM DEN UNITS SERVING: APARTMENTUNITS FED FROM: METER CENTERS (SEE ONE -LINES) 2401120 VOLT 125 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D DISHWASHER 6 7 BATHROOM RECEPTACLE D 0.000 20/1 B *20/1 0.000 D GARBAGE DISPOSAL g 9 WASHER/LAUNDRY D 0.000 *20/1 A 40/2 - 0.000 - D - RANGE - 10 11 SPACE S - - B 12 13 DRYER - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPACE 16 17 SPARE S - 20/1 A 30/2 - 0.000 - D - WSHP - 18 19 SPARE S - 20/1 B 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. m 3 z w 0 0 0 0 W m i T9 j TWO BEDROOM DEN 1/4" = 1'-0' i Tj) GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-466-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-466-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. ` IEL 09'qq i i (Ti) TI TWO BEDROOM DEN RCP 114• = r-o• REVIEWED FO % COMPLIANCE WITIK NFPA 70 - NEC, . DEG 0 3 2015 City of.TukWila BUILDING DIVISION RECEIVED CITY OF TUKWI ILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 1'6/-gi4'A5ELECTRICAL PERMIT ISSUE SCALE: 1 /4" = 1'-01, CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 0. W 3: 0 w F Y Z L Q W J F_ p Y V Q F- z M N v / CONSULTANT REGISTRATION 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826.4447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER TWO BEDROOM DEN E4.10 PANEL 1 BRSE LOCATION: 1-BEDROOM SE CORNER UNITS SERVING: APARTMENT UNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 6 *20/1 0.000 D KITCHEN APPLIANCE 4 5 BATHROOM RECEPTACLE D 0.000 20/1 A *20/1 0.000 D DISHWASHER 6 7 WASHERILAUNDRY D 0.000 *20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 DRYER D 0.000 20/2 A 40/2 - 0.000 - D - RANGE - 10 B 12 13 HEATING - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPARE 16 17 SPARE S - 20/1 A 20/1 - S SPARE 18 19 SPARE S - 20/1 B 20/1 - S SPARE 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. W Z it 0 0 W 0 0 0 W m ONE BEDROOM SE CORNER 114• =1'-0" n ONE BEDROOM SE CORNER RCP 1 /4' =1 '-0• TA I I i :TA: i /_. T7.9 GENE L NOTES 1. ALL 120V, SINGLE PHASE. 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCA11ON WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-468-406. 4. SEE FLOOR PLAN FOR SPARE CONDUIT FOR FUTURE A/C UNIT TO ACCOMMODATE HOTEL OCCUPANCY ON LEVEL 12 AND 13. T6 T6.1 1J AMP :�`"�` � -:ems �✓ REVIEWED FOP COMPLIANCE WITH NFPA 70 - NEC DEL 0 3 2015 City of TUkWila BUILDING DIVISION, RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /4" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT L.6�. w OW F Y a- o �Q W J F— pY V Q F•— z m CV N ��Z VJ CONSULTANT REGISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER ONE BEDROOM SE CORNER E4.11 PLOTTED:31W01510:52:44 AM PANEL SSL LOCATION: STANDARD STUDIO LONG SERVING: APARTMENTUNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 BATHROOM RECEPTACLE D 0.000 20/1 A *20/1 0.000 D DISHWASHER 6 7 WASHER/LAUNDRY D 0.000 *20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 DRYER - D - 0.000 - 20/2 - A 40/2 - 0.000 - D - RANGE - 10 11 B 12 13 HEATING - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPARE 16 17 SPARE S - 20/1 A 20/1 - S SPARE 18 19 SPARE S - 20/1 B 20/1 - S SPARE 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDEARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. 3 v Z 0 J 0 s N 0 Q 0 Z F_ N N 0 N .- ,4 - Wu 10 0 -0 �o STANDARD STUDIO LONG 1 /4" = V-0' ©STANDARD STUDIO LONG RCP 114" = 1•-0' q ..: A GD ....DWA... .: rFh � � `. ti-i1 �Nt fifl(Hl TA I ;TA GENE L NOT'E-5 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-468-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. 4. SEE FLOOR PLAN FOR SPARE CONDUIT FOR FUTURE A/C UNIT TO ACCOMMODATE HOTEL OCCUPANCY ON LEVEL 12 AND 13. ----- - ; T5 REVIEWED -FOR COMPLIANCE WITH NFPA 70 - NEC DEC 0 3 2015 City of -Tukwila BUILDING DIVISION RECEIVE CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 1 %/-qi ZA;5ELECTRICAL PERMIT ISSUE SCALE: 1/4" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 11.. W 3: 0 W Y CL � Q �q v W J pY V Q I— z m N N VJ CONSULTANT REGISTRATION 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264"7 FAX: (206) 826-4446 SHEET TITLE AND NUMBER STANDARD STUDIO LONG E4.12 3/5/201510:40:21 AM PANEL 1 BRN LOCATION: 1-BEDROOM STANDARD NORTH UNITS SERVING: APARTMENT UNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *1511 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 BATHROOM RECEPTACLE D 0.000 20/1 A *20/1 0.000 D DISHWASHER 6 7 WASHERILAUNDRY D 0.000 *20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 DRYER - D - 0.000 - 20/2 - A 40/2 - 0.000 - D - RANGE - 10 11 B 12 13 HEATING - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPARE 16 17 SPARE S - 20/1 A 20/1 - S SPARE 18 19 SPARE S - 20/1 B 20/1 - S SPARE 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. 0 Q 0 z a cn m 0 0 m 0 W m W z O N 0 W CPO 0 ,zo ONE BEDROOM STANDARD NORTH 1/4* = 1'-0" ONE BEDROOM STANDARD NORTH 1/4" = 1'-0" TA} GENE;PAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-468-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTEC11ON OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. 4. SEE FLOOR PLAN FOR SPARE CONDUIT FOR FUTURE A/C UNIT TO ACCOMMODATE HOTEL OCCUPANCY ON LEVEL 12 AND 13. m sm, REVIEWED�FOR COMPLIANCE WITH NFPA 70 - NEC DEC 0 3 2015 City offukWila BUILDING DIVISI_N RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE 0 Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/4" = V-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 6.L_ W 3: p w �1 z O Lu Q W J F_ pY V Q !— z M N T� N ♦1)n V CONSULTANT REGISTRATION 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER ONE BEDROOM STANDARD NORTH E4.13 3151201510:40:55 AM PANEL 1 BRNEC LOCATION: 1-BEDROOM NE CORNER UNITS SERVING: APARTMENTUNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *2011 0.000 D KITCHEN APPLIANCE 4 5 BATHROOM RECEPTACLE D 0.000 20/1 A *20/1 0.000 D DISHWASHER 6 7 WASHER/LAUNDRY D 0.000 *20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 DRYER - D - 0.000 - 20/2 - A 40/2 - 0.000 - D - RANGE - 10 11 B 12 13 HEATING - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPARE 16 17 SPARE S - 20/1 A 20/1 - S SPARE 18 19 SPARE S - 20/1 B 20/1 - S SPARE 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. 01 0-1 Z 0 U w Z 0 0 of 0 w m w Z 0 N 10 0 w in T1 '.• ONE BEDROOM NE CORNER 1/4' = V-0' ` T1 n ONE BEDROOM NE CORNER RCP 1/4" = 1•-0• GENE;;PAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION NTH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-466-406. 4. SEE FLOOR PLAN FOR SPARE CONDUIT FOR FUTURE A/C UNIT TO ACCOMMODATE HOTEL OCCUPANCY ON LEVEL 12 AND 13. REVIEWED FOR COMPLIANCE WITF, NFPA 70 - NEC DEC o 3 2015 City of -Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/4" = V-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: O W Y Z IL 3: w Q W F_ 03: ❑Y 0 Q H z N N N V ) CONSULTANT REGISTRATION /15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 8264446 SHEET TITLE AND NUMBER ONE BEDROOM NE CORNER E4.14 PANEL 1 BRNWC LOCATION: 1-BEDROOM NW CORNER UNITS SERVING: APARTMENT UNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: RUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 BATHROOM RECEPTACLE D 0.000 20/1 A *20/1 0.000 D DISHWASHER 6 7 WASHER/LAUNDRY D 0.000 *20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 DRYER - D - 0.000 - 20/2 - A 40/2 - 0.000 - D - RANGE - 10 11 B 12 13 HEATING - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPARE 16 17 SPARE S - 20/1 A 20/1 - S SPARE 18 19 SPARE I S - 20/1 B 20/1 - S SPARE 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. m 3 v Ld w z Of 0 0 z 0 0 0 w m TB.9 I T1 ONE BEDROOM NW CORNER 1/4" = 1•_0. ONE BEDROOM NW CORNER 1/4' =1'-0" TB.9 i i TBA GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-4613-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-468-406. REVIEWED .FOR COMPLIANCE 70IEC NFPA DEC 0 3 2015 city of.T> Wila mIIn nING DIVIS1N RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/4" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: O W F Y Z 0- 3: a Lu J I— p Y V Q f— z N N N t� v / CONSULTANT REGISTRATION 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER ONE BEDROOM NW CORNER E4.15 PANEL 1 BRWD LOCATION: 1-BEDROOM WEST DEN UNITS SERVING: APARTMENT UNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 BATHROOM RECEPTACLE D 0.000 20/1 A *20/1 0.000 D DISHWASHER 6 7 WASHER/LAUNDRY D 0.000 *20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 DRYER - D - 0.000 - 20/2 - A 40/2 - 0.000 - D - RANGE - 10 11 B 12 13 HEATING - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPARE 16 17 SPARE S - 20/1 A 1512 - 0.000 - M - WSHP (WATER SOURCE HEAT PUMP) (UNIT# 1842 ONLY) 18 19 SPARE S - 20/1 B 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. ONE BEDROOM N w/ DEN 1/4• = 1'-0' 6 ONE BEDROOM N w/ DEN RCP 1/4' = 1'-0' I i TBA GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. 4. SEE FLOOR PLAN FOR SPARE CONDUIT FOR FUTURE A/C UNIT TO ACCOMMODATE HOTEL OCCUPANCY ON LEVEL 12 AND 13. PLAN NOTES !�1 PROVIDE MOTOR —RATED SWITCH, RACEWAY/CONDUCTORS, AND CONNECTIONS AS REQUIRED TO WATER SOURCE HEAT PUMP FOR LEVEL 18 APARTMENT UNIT # 1842. T21: - t T3 -- T I T3 iREVIEWED FOR COMPLIANCE WITH NFPA 70 -NEC DEC 0 3 2015 City Of Tu Wila. RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE 0 Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 114" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA N0. PROJECT ry W 3: O W Y tY z a O �Q W J p Y V Q F- z N N �T N rin V , CONSULTANT REGISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER ONE BEDROOM W DEN E4.16 Q PANEL 1 BRNL LOCATION: 1-BEDROOM NORTH LONG UNITS SERVING: APARTMENT UNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *1511 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 BATHROOM RECEPTACLE D 0.000 20/1 A *20/1 0.000 D DISHWASHER 6 7 WASHER/LAUNDRY D 0.000 *20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 DRYER - D - 0.000 - 20/2 - A 40/2 - 0.000 - D - RANGE - 10 11 B 12 13 HEATING - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPARE 16 17 SPARE S - 20/1 A 20/1 - S SPARE 18 19 SPARE S - 20/1 B 20/1 - S SPARE 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. m 3 Z 0 is of 0 Z 2 0 0 0 W m ONE BEDROOM NORTH LONG v4• = r-o• ONE BEDROOM NORTH LONG RCP v4• = r-0• ONE BEDROOM NORTH LONG 1433 635 SF ONE BEDROOM NORTHLONG 1433 �__N ;TAi T4 T3 i GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-4613-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION -TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER -RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-468-406. REVIEWED.FOR CO P_IANCE WITHNFPA 70 - NEC DEC 0 3 2015 City Of Tukwila BU)LDINr nnnoint.., ity Ot I_- ' VkvV; - DIN, 5„ie RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE 0 Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/4" = 1'-01, CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT w w 3: p w F D- O w Q W J cl V Q H z M N �T N rim V , Q CONSULTANT REGISTRATION '+#' r m , N x, GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER ONE BEDROOM NORTH LONG E4.17 PANEL 1 BRLG LOCATION: 1-BEDROOM LARGE UNITS SERVING: APARTMENT UNITS FED FROM: METER CENTERS (SEE ONE -LINES) ft 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 BATHROOM RECEPTACLE D 0.000 2011 A *20/1 0.000 D DISHWASHER 6 7 WASHER/LAUNDRY D 0.000 *20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 DRYER - D - 0.000 - 20/2 - A 40/2 - 0.000 - D - RANGE - 10 11 B 12 13 HEATING - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPARE 16 17 SPARE S - 20/1 A 15/2 - 0.000 - M - WSHP (WATER SOURCE HEAT PUMP) (UNIT# 1826 ONLY) 18 19 SPARE S - 20/1 B 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH H M D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. ONE BEDROOM LARGE 1/4" = 1'-0' TA; (T )) GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY NTH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCA11ONS REQUIRED PER NEC 406.11 AND WAC 296-466-406. 4. SEE FLOOR PLAN FOR SPARE CONDUIT FOR FUTURE A/C UNIT TO ACCOMMODATE HOTEL OCCUPANCY ON LEVEL 12 AND 13. PLAN NOTES O1 PROVIDE MOTOR -RATED SWITCH, RACEWAY/CONDUCTORS, AND CONNECTIONS AS REQUIRED TO WATER SOURCE HEAT PUMP FOR LEVEL 18 APARTMENT UNIT # 1826. db� AWH., n T5 j -- --- -- 175 — -- -- —� 6 PEVIEV VED.FOP COMPLIANCE WITH NFPA 70 - NEC DEC 0 3 2015 City of Tukwila 6 ONE BEDROOM LARGE RCP BUILDING DIVISION 1/4' =1'-0" RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE 0 I Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/4" = 1'-0. CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT W 3: OW Y z a w Q W J pY V Q t— z N N V ) CONSULTANT REGISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826.4447 FAX: (206) 826.4446 SHEET TITLE AND NUMBER ONE BEDROOM LARGE E4.18 ..: _ .... _ . _9 -'"-_ ---y - ._ , _ _ _ .. -... - ;. �1 ._ .... . 618 E18 : �,, . ; . . �A . . ! I I . ; : : . .. 1.' .= i I ' I ..... ... . , 1 , . : . ..:.... !'1. 1. ,111­1... ..................................: �[� ..... :,*.'. lT : : I . .. . 1. . i . . .. . . . . , `1. i . _.... , ..... . .: ...... 11 H181. ...... _: I . .. i i I ... : . i i i . .:..' A : :. rL,/L- .. .... - ... . . ... ". .....__. _. .... ,:: .' .: :: , p ;: : : �\ _._ - .. .. _.. .... _. .- _ _ .. _ _...__ _ - _ ._. _ _ _.._. _.._ .. __ _ . -. _ ._.... - .. _._... - - _- --.1- -..... _ ._ --._. - .._ _..._ . ._... ...._ ..... - -- - - .. .. i T? 9 .. - _ -- - ---- - - - -- ---- --- ----- - ....:� - - --_- --------- -- --- ----- - - - - - - --- I T7 9 - ---- - --------- ------------- --- - - : :::: :: ....... B18 ::: ..... .. i { .. . . :.::.. .:.::.:.. .. ............... ....I.... ............ ..:; ....... :....:...... .:. .:... . .,: i . - .. .t .. i :; .. .. . . . . . .. : .. : .. . .. . .. .. ... ,.. ': •..% :: 1. 818 .... ;,, :.: ; .:.: , .-. .. .. . . .. ... I . . 1. . . ,: . . I 'I .1 . -.. I i 1 .. .1.1.1. I .. . . I .11 A18 ; I ' ... .. .. - ­ ] i.1.. ....; .. .11: . >. .. ,..., C18 V.V .....:. ' . ,. ... ",.-, :: , :. . ,: ...:.... ..... .- ; 1,-, . ; ....... ....._ ................. .. .. ................. ... .... ...... ..... . . . . . . . . . .. . . I .:. ,...:,............... ,� __. �(�j� ( ... .................... ............... . ... -01 ! , . ........ ... ........ . . G W i B - - ` A aim ................... . ..... :.: •: 9' . 0" . ! . ... . .. .. . i .. �:A .... ..::. C18 :: :: . :: . . ... ;: : k . . . . . :: . . :: ;. ._ ! z ; . . I - - '. %DROOF : .....:::::::::::': :: A1. :> : :: B18 a • : WEST 18 R . .. . .. . . .. .. .. , I GD .. A 8 ;: 1 O�:'�. 1801 i : G i :........'�� .........,i,.iP �i fl I :� �� ........... E::' .. � ...: :.,;.. ... _�i _. :: ;:.% .. i:B18 : : I : :� ;: :e : �,. 8 , :ii i:�: .... .. .. . .!: :: ..': :; l ::I ;' A ..A : ---,(( "."(r / " I :: .. . .. " :.�. I. - :' "I A :�: *� :5. II '�;': _: I. -'! B18 " �'*'**'*_"� ' � .1 . . I .... .. ..... I1828 . .. : . I . . . I r I : I : 1:. . I . . : : .; . � . T .. . . . .: �.. '. 4 _ .. . - . e­­ I-.. �. -1 . : : ... mx�'.: � . . �..�.�­�';:_��'.' .�..' . . .: : : . . . i. : . :111.. I... I . .." - ........ I_ �: : : : ­­­�n�_�.-i i.:.. ... � ..'. 1, ...- �. .''.... "I : .'. � ;.: .­_...:_'.�!;'. . s. . : : . .., ,.l.."'.. .�'..� � .1 I .. 11.11 . ... ... I ... 1. ­.. '­....'.. �.­.... . : , ­. ," !._.."­". . . .. . .. " .. 1: .. - ­ � ..... . ­ - -:: � : . . ..' . . .. - - . . . i.. . :: .... ..... .._ I ! I:: . . . ....................... 11 :: :,.. ...:. A ° ;: :. - ;; 3 BEDROOM .:: , .. : .. . .. I. . W .`. WEST 18TH FLR :.... , ... r :.; E18 . . I I. ;: : 1801 I ----- . : : I '..........:...........:: ............................... . 1 F 1 ; . . . : , �. ... ... . . . I : .. �.;; I C18 I': . : .. ..... ................. ........._ ........... `! ( .; '� i1. I 4 a 11 ;! i I I ! I USB �' • D18 Q i.: : 4�/, ; : :>.. I' - _ _. _...-_....__ .- _... ....- .._. --. _ ... _ . _... .... _ ... . -- --... - ...- _ ......- . -.--... - 1. B18 ... _. ___..- --- - -- -- --.._._._. _ .. - ..__ ...... _. _ . -. .. ...._.._-. E9 ; _..... - - .- - __...... - '---- - _._ .. - .. ... . _. - 1. f ":: ( - _ __ ___... - -- _. _ 1 .. .. . I , ..................... ............................7:...... _ ...........:. ,}� ..... ......,...... , . ..:... .......... ............................:..............:....................... .............................................................................. :.................. .............................i ...... ._ .... ..,.......... ... .. .. .... ..... ... ._ _... ...I........ :.................................. ..............................: , ,. ... .. ,: .. ... _ - .......:................. ,::. 1.1.i 1.,, a , . : ;, i..... i­111 ..... .. .: _111-11,.. .-. ....... .. ` :................................................................ ....................; _. ......... ......... . .........::. .................:.....:. .. ..::..: ..............:.:..................... 1. 1. 1. .. .. ........................ .. >: .. _ .......................................................................... _. .. _.. . . . : ................ _...... . ........................................... ........... ................. ..... .... ..... ......_.. ........ .... . __. .. .._...... ........ .. ... ...................................................... .... .. ..__........_.. : : I ! . I (TMI kJ TI v ( TM I .� (TJ TI THREE BEDROOM WEST 114" = l'-0" W W w F_ N 1 O 0 PANEL 3BRW LOCATION: 3-BEDROOM WEST UNITS SWING: APARTMENTUNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 125 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA Alp PHASE I AM I KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D DISHWASHER 6 7 BATHROOM RECEPTACLE D 0.000 2011 B 1 *20/1 0.000 D GARBAGE DISPOSAL 8 9 WASHER/LAUNDRY D 0.000 *20/1 A 40/2 - 0.000 - D - RANGE - 10 11 SPACE S - - B 12 13 DRYER - D - 0,000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPACE 16 17 SPARE S - 20/1 A 40/2 - 0,000 - M - WSHP (WATER SOURCE HEAT PUMP) - 18 19 SPARE S - 20/1 B r 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. THREE BEDROOM WEST RCP Zia, =V-0• GENERAL NOTES 1. ALL 12OV, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION -TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2, DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAG 296-468-406 FOR TAMPER -RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. PLAN NOTES O1 PROVIDE MOTOR -RATED SWITCH, RACEWAY/CONDUCTORS, AND CONNECTIONS AS REQUIRED TO WATER SOURCE HEAT PUMP. !REVIEWED .FOIE COMPLIANCE WITH NFPA 70 - NEC DEC 0 3 2015 City of'TukWila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 1 5 2015 PERMIT GETTER ISSUE Date I Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/4" = 1'-0. CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB :YPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry LLI 3: aW Y 0- 3: O LUQ W--J 00Y V Q F-- z M N N v J Q 3: . CONSULTANT :GISTRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER THREE BEDROOM WEST E4.19 PANEL 3BRDA LOCATION: 3-BEDROOM DEN -TYPE A UNITS SERVING: APARTMENTUNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 125 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B. *20/1 0.000 D KITCHEN APPLIANCE 4 5 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D DISHWASHER 6 7 BATHROOM RECEPTACLE D 0.000 20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 WASHER/LAUNDRY D 0.000 *20/1 A 40/2 - 0.000 - D - RANGE - 10 11 SPACE S - - B 12 13 DRYER - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPACE 16 17 SPARE S - 20/1 A 40/2 - 0.000 - M - WSHP (WATER SOURCE HEAT PUMP) - 18 19 SPARE S - 20/1 B 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. k'= m 0 0 0 W m W W of 04 N W In T9--......_.. ............... THREE BEDROOM DEN - TYPE A Zia. = r-0^ PLAN NOTES GENERAL NOTES OPROVIDE MOTOR —RATED SWITCH, RACEWAY/CONDUCTORS, AND 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS CONNECTIONS AS REQUIRED TO WATER SOURCE HEAT PUMP. SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH C18 O F18 I f I Ai. i i i I ( i _:. ....... ... .... . _. i :.. ti.., 1G - 01 WB : : -- -; _ : ;GWB'=01 GV1/B GWB 01 z 0 9, � ; 0 ................ :::::...::.:......:......::. .....:......:..... ...........:. :::.. .........:...... .................::..::......:..: ..... ......... ....... :. .. .......... . . ") , 3BEDROO ... :... it 3 DEN S.I.... f TYPE A r — 1809 f 1772 SF ( T9 --- ... - - -- ------------- -- - --- - --- - - ,----- - - --- - -- --- -- --- -- --- -- --- - - --- - -- -- -- -----. ._ . -- --- -- -- -- - - - - - -= --� -- - - -- - - - - -- — -- - ... - -- - -- -- - ------ ---- -- - -- . - --- --- ": •: ;: :::..............:..::. ::..:..... v...,.:......: ;: ................................. I T� THREE BEDROOOM DEN - TYPE A RCP 1/4• = r-0• I I ( I %IWO fTH) (TG; (TF : REVIEWED.FOP COMPLIANCE WITH NFPA 70 - NEC F DEL" 0 3 2015 City OtTukWila RECEIVED CITY OF TUKWILA OCT 15 2015 ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/4" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 1y W 3: o W Y o LuQ W J pY V Q FF— z N N T� N rim V J CONSULTANT REGISTRATION /15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER THREE BEDROOM DEN -TYPEA E4.20 PERMIT CENTER PLAN NOTES O PROVIDE MOTOR —RATED SWITCH, RACEWAY/CONDUCTORS, AND CONNECTIONS AS REQUIRED TO WATER SOURCE HEAT PUMP. GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND. WAC 296-468-4-06. _ T6.1 B18 , PANEL LOCATION: 2-BEDROOM DEN SMALL UNITS 240/120 VOLT 125 AMP MAIN LUGS ONLY SCCR: 22,000 A i 2BRDS SERVING: APARTMENT UNITS 1 PHASE AFC: - - .- -- - - - ---- - - - - -- - - F18 - --- _ -- - - - .- - ------ -- -. - '7 , FED FROM: METER CENTERS (SEE ONE -LINES) 3 WIRE MOUNTING: (LUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.0:00 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 o.0oo D KITCHEN APPLIANCE 4 818 5 LIGHTING AND RECEPTACLE D 0.000 *15/1 A . *20/1 0.000 D DISHWASHER 6 I a 7 BATHROOM RECEPTACLE D 0.000 20/1 B *20/1 0.000 D GARBAGE DISPOSAL g 9 WASHER/LAUNDRY D 0.000 *20l1 A 40/2 0.000 D RANGE 10 ; 2 BEDROOM B18 USB B - - - 12 ! : DEN 18TH . 11 SPACE S 13 DRYER Q 0.000 30/2 A 20/1 0.000 D AC UNIT (NOTE 2) 14 FLOOR SMALL j 15 - - - - B 20/1 - S SPACE 16--�- -- 17 SPARE S - 20/1 A 15/2 0.000 M WSHP (WATER SOURCE HEAT PUMP) 18 1212 SF 19 SPARE S ` - 20/1 B _ i A 20 { A _ D18 I PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA DW E18 A o LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS a CONN. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP I A cALc. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP so 0 O: — — --- — -- — — :: NOTES: * =PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. ; � .......D18 � — B18 � 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. o 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. A 61 .... 8 . GD A ..........d�.. :_ �h . .... 1 ...... ........... I I 1 n TWO BEDROOM DEN SMALL t/4• =, 1 J J Q z w 0 m 0 0 Of 0 w m 3- N N 1 0 0 N ` � r W In ro,3 3 Ob =\ :t J 0 T6.1 T7.9 RECEIVED CITY OF TUKWILA OCT 15 2015 ISSUE A Date Description 1'i C-giZ'(A5ELECTRICAL PERMIT ISSUE SCALE: 1/4" = V-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: O w F z a� o �Q W O'S p Y 0 z¢ F- z cM N s� Z N Q CONSULTANT REGISTRATION /15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 311 SEATTLE, WA 98103 PHONE: (206) 826.4447 FAX: (206) 8264446 SHEET TITLE AND NUMBER TWO BEDROOM DEN SMALL E4.21 PERMIT CENTER T3 ; . . - ....- 4 - - - ---- - T 1 TWO BEDROOM DEN 18TH FLR 1/4' =1'-0" PANEL 2BRD18 LOCATION: 2-BEDROOM DEN 18TH FLR UNITS SERVING: APARTMENT UNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 125 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D DISHWASHER 6 7 BATHROOM RECEPTACLE D 0.000 *20/1 B *2011 0.000 D GARBAGE DISPOSAL 8 9 VVASHER/LAUNDRY D 0.000 20/1 A 40/2 - 0.000 - D - RANGE - 10 11 SPACE S - - B 12 13 DRYER - D - 0.000 - 30/2 - A 20/1 0.000 D AC U NIT (NOTE 2) 14 15 B 20/1 - S SPACE 16 17 SPARE S - 20/1 A 25/2 - 0.000 - M - WSHP (WATER SOURCE HEAT PUMP) - 18 19 SPARE S - 20/1 B 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. 3 U- F- 0 z w 0 0 0 0 W F TWO BEDROOM DEN 18TH FLR RCP 1 /4" =1'-0" GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. PLAN NOTES O1 PROVIDE MOTOR —RATED SWITCH, RACEWAY/CONDUCTORS, AND CONNECTIONS AS REQUIRED TO WATER SOURCE HEAT PUMP. REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC DEC 0 3 2015 City of -Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /4" = l'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 0. ui 3: O w F_ Y of z a� UjQ w� p Y V Q F- z N N N U) CONSULTANT REGISTRATION SroNALY 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 8264446 SHEET TITLE AND NUMBER TWO BEDROOM DEN 18TH FLR E4.22 r THREE BEDROOM DEN NORTH 1/4" = V-0' 3 0 z z w 0 0 0 0 w m w W of FS PANEL 3BRDN LOCATION: 3-BEDROOM DEN NORTH UNITS SERVING: APARTMENTUNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 125 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTINGAND RECEPTACLE D 0.000 *1511 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *1511 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D DISHWASHER 6 7 BATHROOM RECEPTACLE D 0.000 20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 WASHER/LAUNDRY D 0.000 *2011 A 40/2 - 0.000 - D - RANGE - 10 11 SPACE S - - B 12 13 DRYER - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S. SPACE 16 17 SPARE S - 20/1 A 35/2 - 0.000 - M - WSHP (WATER SOURCE HEAT PUMP) - 18 19 SPARE S - 20/1 B 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOADTYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. T2 THREE BEDROOM DEN NORTH RCP 1 /4" =1'-W GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS. OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. PLAN NOTES O1 PROVIDE MOTOR —RATED SWITCH, RACEWAY/CONDUCTORS, AND CONNECTIONS AS REQUIRED TO WATER SOURCE HEAT PUMP. K REVIEWED FOi COMPLIANCE WITFt NFPA 70 a NEC UEL 0 3 2015 City Of Tukwila BUILDING DIVISIC. RECEIVED CITY OF TIJKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /4" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 0. W 3: 0 w F Y �rz ( ) Q W J (D Q :3 z cM N N V i CONSULTANT EGISTRATION v srONAL '�'f 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER THREE BEDROOM DEN NORTH E4.23 PANEL 313RD LOCATION: 3-BEDROOM DEN UNITS SERVING: APARTMENT UNITS FED FROM: METER CENTERS (SEE ONE -LINES) 240/120 VOLT 125 AMP MAIN LUGS ONLY SCCR: 22,000 A 1 PHASE AFC: 3 WIRE MOUNTING: FLUSH CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 5 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D DISHWASHER 6 7 BATHROOM RECEPTACLE D 0.000 20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 9 WASHER/LAUNDRY D 0.000 *20/1 A 40/2 - 0.000 - D - RANGE - 10 11 SPACE S - - B 12 13 DRYER - D - 0.000 - 30/2 - A 20/1 0.000 D AC UNIT (NOTE 2) 14 15 B 20/1 - S SPACE 16 17 SPARE S - 20/1 A 3512 - 0.000 - M - WSHP (WATER SOURCE HEAT PUMP) - 18 19 SPARE S - 2011 B 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP CALC. LOAD 0.00 0.00 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. 3 v z w 0 0 0 0 w m w w of 04 O C N •- W In lO O \ O \ d' O TF THREE BEDROOM DEN 1 /4' =1'-0' PLAN NOTES GENERAL NOTES O PROVIDE MOTOR —RATED SWITCH, RACEWAY/CONDUCTORS, AND 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS CONNECTIONS AS REQUIRED TO WATER SOURCE HEAT PUMP. SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-466-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-46B-406. I TEj TD TC T9 REVIEWED.FOR COMPLIANCE WITH NFPA 70 NEC DEC 0 3 2015 City of -Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWIL A OCT 15 2015 PERMIT CENTER ISSUE 0 Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/4" = l'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT Ll W 3: OLu Y 0- o wQ W� pY CDQ F=— z cM N N t�� VJ CONSULTANT REGISTRATION 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31. SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER THREE BEDROOM DEN E4.24 GENERAL NOTES 1. ALL 120V, SINGLE PHASE, 15A AND 20A BRANCH CIRCUITS SUPPLYING RECEPTACLES IN DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS OF NEC 210.12 AND WAC 296-46B-210. RECEPTACLES SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS. 2. DEVICES SHOWN AS ABOVE COUNTER OR MOUNTED IN BACKSPLASH SHALL BE INSTALLED PER ARCHITECTURAL DETAILS AND REQUIREMENTS. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT. INSTALL HORIZONTALLY WHERE LIMITED SPACE REQUIRES HORIZONTAL MOUNTING. 3. ALL RECEPTACLES SHALL COMPLY WITH NEC ARTICLE 406.11 AND WAC 296-46B-406 FOR TAMPER —RESISTANT RECEPTACLES FOR ALL LOCATIONS REQUIRED PER NEC 406.11 AND WAC 296-466-406. . .... .... __........ . ....... ._. ........ :............... . . USB PANEL LOCATION: 1-BEDROOM WEST UNITS 240/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 22,000 A ......... .......... ....... 1BRW SERVING: APARTMENT UNITS 1 PHASE AFC: a FED FROM: METER CENTERS (SEE ONE -LINES) 3 WIRE MOUNTING: FLUSH D CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT A 1 LIGHTING AND RECEPTACLE D 0.000 *15/1 A *20/1 0.000 D KITCHEN APPLIANCE 2 B 3 LIGHTING AND RECEPTACLE D 0.000 *15/1 B *20/1 0.000 D KITCHEN APPLIANCE 4 T 5 BATHROOM RECEPTACLE D 0.000 *20/1 A *20/1 0.000 D DISHWASHER 6 7 WASHER/LAUNDRY D 0.000 20/1 B *20/1 0.000 D GARBAGE DISPOSAL 8 ...... .. .....�1.1.... .. 9 DRYER D 0.000 20/2 A 40/2 0.000 D RANGE 10 11 - - - - B - - - - 12 13 HEATING D 0.000 30/2 A 20/1 0.000 D AC UNIT (NOTE 2) 14 ..... .......:. .......... 15 - - - - B 20/1 - S SPARE 16 _ ... .. ....... ........... .. ...... 17 SPARE S - 20/1 A 20/1 - S SPARE 18 T :................................. 19 SPARE S - 20/1 B 20/1 - S SPARE 20 PHASE LOAD PHASE A= 0.00 KVA PHASE B= 0.00 KVA ONE BEDROO SE CORNER LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS 1225 CONN. LOAD 0.00 0.00 KVA 0.00 AMP 657 SF CALC. LOAD 0.00 0.00 KVA 0.00 AMP NOTES: * = PROVIDE ARC FAULT (AFCI) CIRCUIT BREAKER. i A 1.) SEE LOAD CALCULATION FOR CIRCUIT LOAD. 2.) DEDICATED CIRCUIT FOR RECEPTACLE LOCATED NEAR LIVING ROOM WINDOW FOR TENANT AC UNIT. 917— GD''or �A . WH .................. ! . ,tWH tW!CJ. ....tW.. ..... � ONE BEDROOM WEST I (TM) ONE BEDROOM WEST RCP 2 v4• = r-0• 3 cn 0 0 w 0 W m W Z 0 N ' 10 N -- W In IN - to \ O \ �t O STAIR 001 ST-501 .............. T7.9 REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC DEL, 0 3 2015 C4 of-TUICWIIS r BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE 0 Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1/4" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W Ow Y z a o Lu W J pY 0Q F- z (V N CV V ) CONSULTANT REGISTRATION 5 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER ONE BEDROOM WEST E4.25 Q KING SE CORNER 1/4" =1'-0" 2 KING STANDARD --T7.9 KING SE CORNER 1 /4' = 1'-0' d...... ...............:.............................,................................................:.......:.......................................................... A B B A@ H nT. KING STANDARD RCP 1 /4' = 1'-0' T7 9 KING SUITE 1/4" = 1'-0• CIRCUIT DESCRIPTION A LIGHTING NOTE 1, NOTE 2 B RECEPTACLE NOTE 2 C BATHROOM NOTE 2 D RECEPTACLE NOTE 2 H HVAC NOTE 1, NOTE 2 NOTE 1. CIRCUIT TO BE CONTROLLED THROUGH RELAY PER ENERGY CODE. NOTE 2. SEE DRAWINGS E2.03 THROUGH E2.11 FOR BRANCH CIRCUITING DESIGNATION TO EACH HOTEL ROOM PLAN NOTES O1 ONE DUPLEX OUTLET SHALL BE CONNECTED TO CIRCUIT A THROUGH GUESTROOM MASTER SWITCH. ANOTHER DUPLEX RECEPTACLE SHALL BE CONNECTED TO UN -SWITCHED CIRCUIT B AS SHOWN. O2 GUEST ROOM MASTER SWITCH TO CONTROL LIGHTING AND HVAC CIRCUIT PER ENERGY CODE. O3 PROVIDE HEARING IMPAIRED VISUAL DEVICE IN HANDICAP UNITS. O4 CONNECT RECEPTACLE TO CIRCUIT A BEFORE THE GUEST ROOM MASTER SWITCH. (TA) i (TA) ETA Y I i # _ ............ : .:.. B B A :: i I A KING NORTH GWB-04 .....:..:• 323H � - HA : i - R :: . • 7 10 04 :.:: iN: 2 A O .. .. ..-� ......... .. , ... .... ... .... .... .. .. ., ................................ .... .... < i B A :C: A B A H . .:. HG ;F : : <... � I................................................................................................................................................. .... ...... ..................... ........ ............. ........... :::..-. : : ........................:.......:...:........:.........._..................... ..:s...........> KING SUITE ACCESSIBLE ........ 401 H KING NORTH ,553 SF 1/4"=''-0- 8 KING NORTH RCP ELECT' 114• = r-o• 400D 88 SF ........ • :: '... ...... il QUEEN QUEEN 1/4• =1.-0, 0 B A HC . QUEEN QUEEN TUB 304H 333 SF Ali KING SUITE RCP 1/4' =1'-0' REVIEWED FOR t COMPLIANCE WITH NFPA 70 - NEC DEL 0 3 2015 City Of•TukWila BUILDING DIVlslnA.- RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: 1 /4" = 1'-0" CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB EYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: OW Y Q z pWJ Q V Q f-- z CM N T� N U) CONSULTANT REGISTRATION n:. GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 314 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826.4446 SHEET• TITLE AND NUMBER HOTEL ROOM TYPICAL UNITS E5.01 t 0 W C7 Q J z W I iTM' gay �le,64. e ti . s 5 V EUSERC HOTEL HOUSE I (7 K A) METER METER ADB C — AP1 AL1 L P A AX 1L n 1 ST FLOOR ELECTRICAL ROOM 103 / EM ELEC RM 103-A / CATV ROOM 104 i� — T6 i ... ./ ...`........................................ — T6.1 ATF n 3RD FLOOR ELECTRICAL ROOM 300-E Y 1 /4" = V-0" 2500 BUS 800A DISCONNECT TAP BOX BLANK SECTION (TO AVOID DOOR FRAME) — TB.9 1ST FLOOR ELECTRICAL ROOM 118 T6.1 T7.9 5 4TH FLOOR ELECTRICAL ROOM 400-E 1/4' = V-0' GENERAL NOTES 1. SEE DRAWINGS E2.01 ADDITIONAL ELECTRICAL EQUIPMENT LOCATIONS. PLAN NOTES O1 PROVIDE 8"X8"X4" JUNCTION BOX FOR AMR SYSTEM LOCATED ON WALL SPACE ABOVE DISCONNECT SWITCH. PROVIDE 2" CHASE NIPPLE IN THE SIDE OF JUNCTION FOR ANTENNA LOOP. PROVIDE 2"C STUB —UP TO METER CENTERS AMR JUNCTION BOX FLOOR ABOVE. O PROVIDE 2'X2' PLYWOOD AND 120 VOLT RECEPTACLE FOR AMR REPEATER. PROVIDE 2"C STUB —UP TO LEVEL 4. �2ND FLOOR ELECTRICAL ROOM 217 1 /4" = 1'-0" HP4 T-4H HR4A 1600A BUS DUCT TA.6 4TH FLOOR ELECTRICAL ROOM 421 City of�TukWila n BUILDING DIVISION ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB :YPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT N W 3: O W Y tY z a� o Lu W� pY V QH z M N �1 VJ CONSULTANT :GISTRATION y SIaN�L '�°f 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826.4446 SHEET TITLE AND NUMBER 1 ST-4TH FLOORS ENLARGED ELECTRICAL ROOM PLANS E6.01 T6 /J T6. 1 T7 2500 BUS 1 ... ........ ........ TAP BOX MC4 SECTION. 2' 19 METERS Li AX5 ---- -... _ _.. _T7.9 `. T-ARX5 v _ ARX5- --- ---- --- n 5TH FLOOR ENLARGED ELECTRICAL ROOM 500-E 1 /4" = V-0" 2500 BUS 800A DISCONNECT ............................ : ........................ 0 6TH FLOOR ENLARGED ELECT/CAN ROOM D-601 1/4" = V-0" T-8 TAP BOX MC6 SEC 2 _ FR ,, 19 METERS TAP BOX-= MC8 SEC 1 BLANK SECTION (TO AVOID DOOR FRAM6- ARX7 _ .i T � 1 6TH FLOOR ELECTRICAL ROOM 621 J ----T7.9 t� 400 `AMP DISC: " f^.' : ................. 8 1200A BUS +DUCT TA.6 H FLOOR ELECTRICAL ROOM 700-E n 8TH FLOOR ELECTRICAL ROOM 800-E n 8TH FLOOR ELECTRICAL ROOM 821 1/4" = V-0" 1/4" = V-0" = 1.-0. w N 0 0 J r3 � 0o Z CO , ik -i 0 to O.. 64 - 04 0 O O o 10 �W U O :)F- OWLd d J O T7.9 T7.9 1_� PLAN NOTES O1 PROVIDE 8"X8"X4" JUNCTION BOX FOR AMR SYSTEM LOCATED ON WALL SPACE ABOVE DISCONNECT SWITCH. PROVIDE 2" CHASE NIPPLE IN THE SIDE OF JUNCTION FOR ANTENNA LOOP. PROVIDE 2"C STUB -UP TO METER CENTERS AMR JUNCTION BOX FLOOR ABOVE. O2 PROVIDE 8"X8"X4" JUNCTION BOX FOR AMR SYSTEM PROVIDE 2" CHASE NIPPLE IN THE SIDE OF JUNCTION FOR ANTENNA LOOP. PROVIDE 2"C STUB -UP TO METER CENTERS AMR JUNCTION BOX FLOOR ABOVE. REVIEWED .FOIE COMPLIANCE WITI NFPA 70 - NEC LIEL 0 3 2015 City of-Tukrita BUILDING DIVISIO�- RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER 0 2' 4' 8' ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA N0. PROJECT W O W Y !Y CL w Q W J � pY `./ Q H z N N T� N V / d CONSULTANT REGISTRATION 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER 5TH-8TH FLOORS ENLARGED ELECTRICAL ROOM PLANS E0.02 T6 i T6.1 T7 2500 BUS DUCT)I 2 J TAP BOX MC8 SECTION..'"2 19 METERS AP9 ---- - - -- — — T—AP9" -- -------- -T7.9 0 ': AR9 -- --- _--- ----- ------T8 l 2500 BUS DU( TAP 0 w Q J z w V) 0 0 Ell F 3 i(ncio 0)JO O) a N � 00 c� wvo OF-N \ OWE .:- W OR n 9TH FLOOR ENLARGED ELECTRICAL ROOM 900-E 1 /4' = 1'-0" T6 - T6.1 —� T7 4)11TH FLOOR ELECT/CAN ROOM 1100-E 1/4" =1'-0' 2 10TH FLOOR ENLARGED ELECT/CAN ROOM 1000-E 1/4' = l'-0' HP10 HR10A T—HR10A H R10B HR10C 400 AMP DISC.- 1 10TH FLOOR ELECTRICAL ROOM 1021 J PLAN NOTES O1 PROVIDE 8"X8"X4" JUNCTION BOX FOR AMR SYSTEM LOCATED ON WALL SPACE ABOVE DISCONNECT SWITCH. PROVIDE 2" CHASE NIPPLE IN THE SIDE OF JUNCTION FOR ANTENNA LOOP. PROVIDE 2"C STUB —UP TO METER CENTERS AMR JUNCTION BOX FLOOR ABOVE. O2 PROVIDE 8"X8"X4" JUNCTION BOX FOR AMR SYSTEM PROVIDE 2" CHASE NIPPLE IN THE SIDE OF JUNC11ON FOR ANTENNA LOOP. PROVIDE 2"C STUB —UP TO METER CENTERS AMR JUNCTION BOX FLOOR ABOVE. v REVIEVVED.FOR COMPLIANCE WITH NFPA 70 - NEC DEL 0 3 2015 City of-TukWila BUILDING DIVISION ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE. ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT r W 4 w Y z a� O w< � pY V QH z CM N T� N V / CONSULTANT ZEGISTRATION SIOPi�L`'� 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31, SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826.4446 SHEET TITLE AND NUMBER 9TH-13TH FLOORS ENLARGED ELECTRICAL ROOM PLANS E6.03 GENERAL NOTES 1. SEE DRAWINGS E1.10, E2.01 AND E2.19 FOR ADDITIONAL ELECTRICAL EQUIPMENT LOCATIONS. �, T6 T6 PLAN NOTES - 1 PROVIDE 8"X8"X4" JUNCTION BOX FOR AMR SYSTEM LOCATED ON WALL SPACE ABOVE DISCONNECT SWITCH. PROVIDE 2" CHASE NIPPLE IN THE SIDE OF JUNCTION FOR _° ANTENNA LOOP. PROVIDE 2"C STUB -UP TO METER CENTERS AMR JUNCTION BOX FLOOR ABOVE. PROVIDE 8"X8"X4" JUNCTION BOX FOR AMR SYSTEM T6. T6' PROVIDE 2" CHASE NIPPLE IN THE SIDE OF JUNCTION FOR _. ANTENNA LOOP. PROVIDE 2"C STUB -UP TO METER CENTERS ---" — AMR JUNC11ON BOX FLOOR ABOVE. PROVIDE 2'X2' PLYWOOD WITH 120 VOLT RECEPTACLE FOR ;. T7 _ T7 AMR REPEATER PROVIDE 2"C TL 17. PROVIDE 2"C O LEVEL WITH 8"X8"X6" NEMA UP TO ROOF AREA WI MA 3R 400A DISC F-400A DISC. ENCLOSURE FOR AMR ANTENNA. COORDINATE ANTENNA "CELLNET". 2500 BUS =3 2500 BUS---? LOCA11ON WITH OPROBACKBOARVIDE 4 FROM JUNCTION 8 TO AMR PLYWOOD PROVID BOX FT-15 FT-6 O5 ROUTE RISER CONDUIT IN SLAB TO AVOID "AX" ELECTRICAL GEAR. T7.9 n 14TH FLOOR ENLARGED ELECT/CAN ROOM 1400-E 114" = V-0- 2500 800A DISCONNECT BLANK SECTION (TO AVOID DOOR FRAME) - 400A/ DISC. T7.9 4 17TH FLOOR ELECT/CAN ROOM 1700-E 114" =1'-0' w WE U) w Of 0 0 L IVY =Z �a N � o ow� J W0O N OPT O W � _I p �W .- WAD BLANK SECTION 28 METERS (TO AVOID DOOR FRAME) Z 15TH FLOOR ENLARGED ELECT/CAN ROOM 1500-E 1 w = 1 •-0• .............. T7 F 2500 BUS400A." DISC. VAX18 I ( I T-AX)118 XR18 1 ;::; ......... _...... ._..... n 18TH FLOOR ELECT/CATV ROOM 1800-E 114- = 1'-0' T7.9 16TH FLOOR ENLARGED ELECT/CAN ROOM 1600-E va• = r-0' REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC DEC 0 3 2015 City Of Tukwila - [ BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER 7�F=9mmmlmmmm 2' 4' 8' ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT noo ui 3: p w F Y a © w -1 W -1 F— pY V QH z cM N T� N ri� V CONSULTANT REGISTRATION _ SIGNAL ��` 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 8264446 SHEET TITLE AND NUMBER 14TH-18TH FLOORES ENLARGED ELECTRICAL ROOM PLANS E6.04 W z J W N Z N 00 O o •. Wto PSE TRANSFORMER 2,500 KVA GENERATOR LOAD CALCULATION xx,xxx = CALCULATED AVAILABLE FAULT CURRENT (AFC), SHOWN IN AMPS. DEMAND LOAD REFER TO GENERAL NOTE #2, THIS SHEET, FOR MORE INFORMATION. 1). FIRE PUMP NO. 1 (150HP) 149KVA S-P 51 = SURGE PROTECTIVE DEVICE (SPD) 2). FIRE PUMP NO. 2 (75HP) 79KVA 3). ATS - 1 624.47KVA SELECTIVE COORDINATION CIRCUITS NOT IN USE IN GENERATOR MODE. 3 ELEVATORS (129.69 KVA) 129.69KVA A SELECTIVE COORDINATION STUDY SHALL BE PROVIDED 7 7 1/2HP SMOKE REMOVAL FAN 64.01KVA AND COORDINATED PER NEC ARTICLE 700 "EMERGENCY 7 3 HP SMOKE REMOVAL FAN 27.9KVA SYSTEMS", SECTION 700.28 "SELECTIVE COORDINATION". WIOLL OPNLY ERATE OUT AT ONEOF E 11ME)7 1/2HP & (7) 3HP TOTAL 630.87KVA 4). ATS - 2 (WILL BE SHUNT TRIPPED WHEN FIRE PUMP IS ON) GENERATOR PROPOSED 750KW/940KVA WITH 1500 GALLON FUEL TANK N U W U) co U (SEE SHEET E7.02) o 800Y MC8-SEC-1 T8 (19) 13,585 300KVA 7 6 APT. PNL 100A 100Sfil 800Y 801-823 800A 1 - 480/208V MC6-SEC-2 (19) 7 6 APT. PNL 100A 100S 701-723 800Y MC6-SEC-1 T6 (19) 13,611 300KVA 7 6 APT. PNL 100A 100S 800Y 601-623 800A 1 - 480/208V MC4-SEC-2 (19) 7 6 APT. PNL 100A 100S 501-523 MC4-SEC-1 800Y 13,638 T4 (19) 300KVA 7 6 APT. PNL 100A 100S 800Y 401-423 800A 1 - 480/208V MC3 (32) T3 (19) 13,652 300KVA APT. PNL 7 6 301-323 100A 100S 800Y 1 - 480/208V 800A (13) 7 6 APT. PNL [100A�,O�OS 201-223 46,955 400A 400A 47,587 l 400A 400A 400A 48,541 400A CIRCUIT LEGEND (ALL CONDUCTORS ARE COPPER, UNLESS NOTED OTHERWISE) 3�, 3W+G (4 WIRES TOTAL) 3�, 3W+N+G (5 WIRES TOTAL) 1 �, 2W+N+G (4 WIRES TOTAL) CKT ID ® RACEWAY/WIRE CKT AMPS CKT ID ® RACEWAY/WIRE CKT AMPS CKT RACEWAY/WIRE ,MPS 20A 3/4"C, 3#12, #12G 20 20Y 3/4"C, 4#12, #12G 20 20S 3/4"C, 3#12, #12G 20 30A 3/4"C, 3#10, #10G 30 30Y 3/4"C, 4#10, #10G 30 30S 3/4"C, 3#10, #10G 30 40A 3/4"C, 3#8, #10G 40 40Y 3/4"C, 4#8, #10G 40 40S 3/4"C, 3#8, #10G 40 50A 3/4"C, 3#8, #10G 50 50Y 3/4"C, 4#8, #10G 50 50S 3/4"C, 3#8, #10G 50 60A 1 "C, 3#6, #10G 60 60Y 1 "C, 4#6, #1 OG 60 60S 1 "C, 3#6, #10G 60 70A 1-1/4-C, 3#4, #8G 70 70Y 1-1/4-C. 4#4, #8G 70 70S 1-1/4-C, 3#4, #8G 70 80A 1-1 /4"C, 3#4, #8G 80 80Y 1-1 /4"C, 4#4, #8G 80 80S 1-1 /4"C, 3#4, #8G 80 90A 1-1/4-C, 3#3, #8G 90 90Y 1-1 /4"C, 4#3, #8G 90 90S 1-1 /4"C, 3#3, #8G 90 100A 1-1 /4"C, 3#2, #8G 100 100Y 1-1 /4"C, 4#2, #8G 100 100S 1-1 /4"C, 3#2, #8G 100 125A 2"C, 3#2/0 AL, #6G 125 125Y 2"C, 4#2/0 AL, #6G 125 125S 2"C, 3#2/0 AL, #6G 125 150A 2"C, 3#3/0 AL, #6G 150 150Y 2"C, 4#3/0 AL, #6G 150 150S 2"C, 3#3/0 AL, #6G 150 175A 2"C, 3#4/0 AL, #6G 175 175Y 2-1 /2"C, 4#4/0 AL, #6G 175 - - - 200A 2-1/2"C, 3-250KCM AL, #6G 200 200Y 2-1/2"C, 4-250KCM AL, #6G 200 - - - 225A 2-1/2"C, 3-30OKCM AL, #4G 225 225Y 3"C, 4-300KCM AL, #4G 225 - - - 250A 3"C, 3-350KCM AL, #4G 250 250Y 3"C, 4-350KCM AL, #4G 250 - - - 300A 3"C, 3-500KCM AL, #4G 300 300Y 3-1 /2"C, 4-500KCM AL, #4G 300 - - - 400A 3-1 /2"C, 3-50OKCM, #3G 400 400Y 4"C, 4-50OKCM, #3G 400 - - - 600A 2-SETS [3"C, 3-500KCM AL, #1G] 600 600Y 2-SETS [3-1/2"C, 4-500KCM AL, #1G] 600 - - - 800A 2-SETS (3-1/2-C, 3-50OKCM, #1 /OG] 800 800Y 2-SETS [3-1/2-C, 4-50OKCM, #1 /OG] 800 - - - - - - 800YB 4-SETS [2-1 /2"C, 4-250KCM AL, #1 /OG] 800 - - - - - - 900Y 3-SETS [3-1 /2"C, 4-50OKCM, #1 /OG] 900 - - - - - - 1200Y 4-SETS [3-1 /2"C, 4-500KCM AL, #1 /OG] 1200 - - - - - - 1600Y 6-SETS [3-1/2-C, 4-500KCM AL, #1 /OG] 1600 - - - - - - 2500Y 9-SETS [3-1 /2"C, 4-500KCM AL, #1 /0G] 2500 - - - - - --r--1 3000Y 10-SETS [3-1/2-C, 4-500KCM AL, #1 /OG] 130001 rn 0) O] � exx- XrX 0 0 0 0 0 0 F- p 250Y SPDI T-ARX7 ARX7 SPD 30KVA AX7 `` 60A 100Y 480/208V -_`' 250Y T-ARX51 ARX5 MC�%4-M80/208V 30KVA 100Y _ 2500A BUS DUCT BD-2 2500Y 49,338 ' V 2"C TO ROOF T-ARXG AREA VIA FIRE T-TR 15KVA, 480- ALARM CHASE 71 SPD 240/120V 1-PHASE) 400Y TP 60A 100Y TR ARXG 60S 3/4"C, 30KVA _ - 2#8,#10G MSB-1 480/208V I, 56,500 30:25C A T-GR a 8 ADB I� 30KVA-480 208V � AXG 0 1600A 1 125Y GP 60A 100Y GR 2 0 _ 400 200Y 400 _ T-AR1 3000Y rr EUSERC O 1 0 SECTION 100A 225Y AR1 250 250Y ,4P1 75KVA - EUSERC MSB-2 100 480/208V 3000Y SECTION 3000A 100Y AL1 250Y O5 800 1600 8 800Y 800YB 1600Y SPARE IL 125Y 1600 8 1600Y SPD 60Y AX1L 400Y 7. 9,342 T-ARX1 200Y 37,155 39,036 ATS-1 45KVA SPD 3 (PRIMARY) 3 O 800A 800Y AX1 100A 150Y ARX1 (SECONDARY) LIFE 600A O 75HP O 150HP SAFETY SPD BUSSED FIRE PUMP FIRE PUMP 480/208V - SPD GUTTER �2 200A @2 400A 4kT. 200Y HX1 200Y 400Y -too 20Y 5HP JOCKEY PUMP 200Y 200 200Y 750KW GENERATOR 400Y 400Y (480Y/277V) 400 12 A _ 600 BUSSED 600Y GU ER 800Y 800Y 900 'BG 2' 800 900Y - G 200Y 200Y 200 8,248 = PROVIDE GROUND ROD AND BOND NEUTRAL AND _ GROUNDING CONDUCTOR ONE LINE DIAGRAM (LEVELS 1-8 (ROOM 104) COMMUNICATION PLYWOOD GROUND BUS 4" C 4" C T-8H 75KVA #3/0 CU ,. do 400A HP8 100A 225Y HR8A COMMUNICATION 400A PLYWOOD GROUND 480/208V - 1 HR8B BUS HR8C u u u u #3/0 CU COMMUNICATION PLYWOOD GROUND BUS 4" C 4" C T-6H „ 37,501 75KVA #3/0 CU cr0 400A 100A 225Y H HR6A COMMUNICATION ; 400A PLYWOOD GROUND 480/208V- 1 HR66 BUS HR6C 4"C 4"C #3/0 CU COMMUNICATION PLYWOOD GROUND BUS 4"C 4"C T-4H u u 38,660 751 #3/0 CU 400A HP4 100A 225Y HR4A COMMUNICATION ' 400A PLYWOOD GROUND ' 480/208V - 1 HR4B BUS HR4C 1200A BUS DUCT #3/0 CU BD-1 ` COMMUNICATION PLYWOOD GROUND BUS 4-C 4"C T-2H #3/0 CU 39,669 75KVA COMMUNICATION HR2A PLYWOOD GROUND 100A HR26 BUS �, 40oA 480/208V - 1 � 400Y HP2 HR2C 4" C 4" #3/0 CU rj-1 39,849 TO Comm �-#3/0 CU CO-�� 4" C TO RM 104 HOTEL VAULT TO SERVICE COMMUNICATIONS GROUND UNDER 1ST FLR SLAB (RM 103) 40.151 HDB 1600A 1200 1200Y 150 150Y ERVLLJ O T-HY1 45KVA 100 100A ]EIZ150Y HY1 480/208V - 400 400Y HM1 T-HKR 200 45KVA 200Y HK1 1OOA 150Y HKR 200 LA-1--1 200Y 480/208V _ 42,835 T-HR 1 Q ATS-2. 75KVA 200A OPTIONAL 200Y HL1 100A 225Y HR1 TANIr. BY 480/208V _ 60Y HC1 4" C TO RM 104 HOTEL COMMUNICATIONS UNDER 1ST FLR SLAB GENERAL NOTES 1. CONTRACTOR TO UPDATE ONE LINE AND LOAD CALCULATIONS UPON COMPLE11ON OF DESIGN. 2. REFER TO PANEL SCHEDULES FOR CALCULATED AVAILABLE FAULT CURRENT (AFC) VALUES AND SHORT-CIRCUIT CURRENT RATING (SCCR) OF DISTRIBUTION EQUIPMENT AND PANELBOARDS. PLAN NOTES O1 GROUND TO COMMON GROUNDING ELECTRODE WITH 3/0 CU. O2 COMBINATION SUSE RATED FIRE PUMP CONTROLLER AND AUTOMATIC -TRANSFER SWITCH PROVIDED BY OTHERS, ELECTRICAL CONTRACTOR SHALL PROVIDE CONNECTIONS. O3 EUSERC C.T. CAN WITH CTs AND KWH METER BY ELECTRICAL CONTRACTOR. O4 4-POLE TRANSFER SWITCH. O5 CUSTOMER METERING FOR WA STATE ENERGY CODE. (63 UNIT PANELBOARDS 20-FEET AND LESS FROM METER CENTER 'MCX' SHALL BE MINIMUM 22,000 SCCR RATED. O7 UNIT PANELBOARDS MORE THAN 20-FEET FROM METER CENTER 'MCX' SHALL BE MINIMUM 10,000 SCCR RATED. O8 GROUND -FAULT PROTECTION (GFP) PER NEC 230.95. Og MECHANICAL UNIT REFER TO SHEET EO.03 FOR MORE INFORMATION. (SEE SHEET E7.02) LEVEL 9 #3/0 CU COMMUNICATION GROUND PLYWOOD BUS LEVEL 8 u u #3/0 CU COMMUNICATION GROUND PLYWOOD BUS 17LEVEL 7 u u #3/0 CU COMMUNICATION GROUND PLYWOOD BUS LEVEL 6 #3/0 CU COMMUNICATION GROUND PLYWOOD BUS 17 LEVEL 5 u u #3/0 CU COMMUNICATION GROUND PLYWOOD BUS A A LEVEL 4 u u #3/0 CU COMMUNICATION GROUND PLYWOOD BUS 17LEVEL 5 I 1. #3/--0 - CU COMMUNICATION GROUND PLYWOOD r7 BUS LEVEL 2 #3/0 CU REVIEWED FO( COMPLIANCE WIT! I, NFPA 70 - NEC DEC 0 3 2015 City of -Tulcwils BUILDING DIVISION LEVEL 1 RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB AN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: pw F Y z a O �Q w� >- 0p Y �Fn V Q F- z M N N t= v� Q JLTANT REGISTRATION 5 GROUP WEST. ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826-4A46 SHEET TITLE AND NUMBER ONE LINE DIAGRAM (LEVELS 1-8) E7.01 SCALE: NONE 3 v 04 z J z 04 00 N .- O •- W Lr, 'N O"� o� �o FX-X7X-XXl = CALCULATED AVAILABLE FAULT CURRENT (AFC), SHOWN IN AMPS. REFER TO GENERAL NOTE #2, THIS SHEET, FOR MORE INFORMATION. SPD = SURGE PROTECTIVE DEVICE (SPD) SELECTIVE COORDINATION A SELECTIVE COORDINATION STUDY SHALL BE PROVIDED AND COORDINATED PER NEC ARTICLE 700 "EMERGENCY SYSTEMS-, SECTION 700.28 "SELECTIVE COORDINATION". CIRCUIT LEGEND (ALL CONDUCTORS ARE COPPER, UNLESS NOTED OTHERWISE) 3�, 3W+G (4 WIRES TOTAL) 3t, 3W+N+G (5 WIRES TOTAL) 1t, 2W+N+G (4 WIRES TOTAL) CKT ID ® RACEWAY/1MRE CKT AMPS CKT ID ® RACEWAY/VNRE CKT AMPS CKT ID ® RACEWAY/1MRE CKT AMPS 20A 3/4"C, 3#12, #12G 20 20Y 3/4-C, 4#12, #12G 20 20S 3/4"C, 3#12, #12G 20 30A 3/4-C, 3#10, #10G 30 30Y 3/4-C, 4#10, #10G 30 30S 3/4-C, 3#10, #10G 30 40A 3/4"C, 3#8, #1OG 40 40Y 3/4-C, 4#8, #10G 40 40S 3/4"C, 3#8, #10G 40 50A 3/4-C, 3#8, #1OG 50 50Y 3/4-C, 4#8, #1OG 50 50S 3/4"C, 3#8, #1OG 50 60A 1-C, 3#6, #1 OG 60 60Y 1-C, 4#6, #1 OG 60 60S 1-C, 3#6, #1 OG 60 70A 1-1 /4"C, 3#4, #8G 70 70Y 1-1 /4-C, 4#4, #8G 70 70S 1-1 /4"C, 3#4, #8G 70 80A 1-1 /4-C, 3#4, #8G 80 80Y 1-1 /4-C, 4#4, #8G 80 80S 1-1/4-C, 3#4, #8G 80 90A 1-1/4-C. 3#3, #8G 90 90Y 1-1 /4-C, 4#3, #8G 90 90S 1-1 /4-C, 3#3, #8G 90 100A 1-1 /4-C, 3#2, #8G 100 1 OOY 1-1 /4-C, 4#2, #8G 100 100S 1-1 /4"C, 3#2, #8G 100 125A 2"C, 3#2/0 AL, #6G 125 125Y 2-C, 4#2/0 AL, #6G 125 125S 20C, 3#2/0 AL, #6G 125 150A 2"C, 3#3/0 AL, #6G 150 150Y 2-C, 4#3/0 AL, #6G 150 150S 2-C, 3#3/0 AL, #6G 150 175A 2-C, 3#4/0 AL, #6G 175 175Y 2-1/2-C, 4#4/0 AL, #6G 175 175S 2-C, 3#4/0 AL, #6G 175 200A 2-1 /2"C, 3-250KCM AL, #6G 200 200Y 2-1/2-C, 4-250KCM AL, #6G 200 200S 2-1 /2"C, 3-250KCM AL, #6G 200 225A 2-1/2-C, 3-300KCM AL, #4G 225 225Y 3-C, 4-300KCM AL, #4G 225 - - - 250A 3-C, 3-350KCM AL, #4G 250 250Y 3"C, 4-350KCM AL, #4G 250 - - - 300A 3"C, 3-500KCM AL, #4G 300 300Y 3-1 /2"C, 4-500KCM AL, #4G 300 - - - 400A 3-1/2-C, 3-500KCM, #3G 400 400Y 4-C, 4-500KCM, #3G 400 - - - 600A 2-SETS [3"C, 3-500KCM AL, #1 G] 600 600Y 2-SETS [3-1 /2-C, 4-500KCM AL, #1 G] 600 - - - 800A 2-SETS [3-1 /2"C, 3-500KCM, #1 /OG] 800 800Y 2-SETS [3-1 /2"C, 4-500KCM, #1 /OG] 800 - - - - - - 1200Y 4-SETS [3-1 /2"C, 4-500KCM AL, #1 /OG] 1200 - - - - - - 1600Y 6-SETS [3-1 /2"C, 4-500KCM AL, #1 /OG] 1600 - - - - - - 2500Y 9-SETS [3-1 /2-C, 4-500KCM AL, #1 /OG] 2500 - - ELIE - - - _-F 4000Y 13-SETS [3-1 /2"C, 4-500KCM AL, #1 /OG] 4000 1 - - GENERAL NOTES 1. CONTRACTOR TO UPDATE ONE LINE AND LOAD CALCULATIONS UPON COMPLETION OF DESIGN. 2. REFER TO PANEL SCHEDULES FOR CALCULATED AVAILABLE FAULT CURRENT (AFC) VALUES AND SHORT-CIRCUIT CURRENT RATING (SCCR) OF DISTRIBUTION EQUIPMENT AND PANELBOARDS. PLAN NOTES O1 GROUND TO COMMON GROUNDING ELECTRODE WITH 3/0 CU. O2 UNIT PANELBOARDS 20-FEET AND LESS FROM METER CENTER 'MCX' SHALL BE MINIMUM 22,000 SCCR RATED. O3 UNIT PANELBOARDS MORE THAN 20-FEET FROM METER CENTER 'MCX' SHALL BE MINIMUM 10,000 SCCR RATED. O4 UNIT PANELBOARDS SHALL BE MINIMUM 10,000 SCCR RATED. 400A 400A T19 T-ARX19 SEC2 75KVA 30KVA SPD SPD SPD SPD HP19 200S AR19 225Y 150A AP19 AX19'` 60A 100Y ARX19 ELEV ELEV 1,2,3 ELEV 4,5,6 TO ELEVATOR 1 - 480/208V SPD 1 - 480/208V 60Y POWER POWER CONTROL ROOM PANEL PANEL MC18 (15) 10,608 225 8 43,989 T APT. PNL COMMUNICATION O 1801-1839 125A 125S o 800Y 400A PLYWOOD GROUND 800A 400A BUS 1 - 480/208V CA��:)4A80/208V= n n n n 4" C MC17 #3/0 CU (28) 10,616 T17 225KVA PNL COMMUNICATION44,252 OAPT. 1701-1739 125A 125S 0 800Y 400A o ' PLLYWOOD GROUND 800A 400A' BUS 1 - 480/2O8V n n n n 4" C i MC16 (28) 10,624 T16 44,514 #3/0 CU 225KVA ON COMMUNICATION O APT. PNL 1601-1639 100A 1 OOS 0 400A GROUND 800A "=480/208V 400A BUS i n n ITS n 4" C MC15 (28) 10,632 T15 44,777 u u u u #3/0 CU 225KVA COMMUNICATION APT. PNL 4 1501-1539 100A 100S 0 800Y 400A c PLYWOOD GROUND 800A 400A BUS 1 - 480/208V n n n n 4" C MC14 T14 u u u u #3/0 CU (28) 10,640 225KVA 45,084. CO ON OAPT. PNL 1401-1439 100A 100S 0 800Y 400A 250Y PLYWOOD GROUND 800A 400A BUS 1 - 480/208V n n n n 4" C MC13 #3/0 CU (28) 10,648 3 225KVA45,393 PNL CO ON OAPT. 1301-1339 100A 100S 800Y 40OA PLYWOOD GROUND 800A 400A BUS 1 - 480/208V n n n n 4" C MC12 u u u u #3/0 CU (33) 13,531 T12 300KVA 45,70!;�o APT. PNL COMMUNICATION 3 2 1201-1239 C@7 100A 100S 800Y 400A PLYWOOD GROUND 800A 400A BUS 1 - 480/208V n n n n 4" C MC10-SEC-2 SPD (19) T-ARX11 ARX11 #3/0 CU APT. PNL 3 2 100A 100S SPD 30KVA COMMUNICATION COMMUNICATION GROUND 1101-1123 PLYWOOD GROUND PLYWOOD BUS AX'1'1<` 60A 100Y 17 BUS 1 480/208V - 1 - 4" C ^ ^ ^ ^ n n n 4" C 800Y 35,503 T-10H 75KVA u u u #3/0 CU MC10-SEC-1 (19) T10 46,326 #3/0 CU 400A HP10 100A 225Y HR10A 300KVAAE COMMUNICATION 400A COMMUNICATION GROUND 3 2 APT. PNL 100A 100S 400AJN8D0OA=-1 PLYWOOD GROUND 480/208V - 1 HR10B PLYWOOD BUS 1001-1023 400A BUS HR10C - 480/208V n n Cl rt n n n 4" C 4" C #3/0 CU u u u u MC8-SEC-2 T-AP9 #3/0 CU (19) 45KVA COMMUNICATION GROUND APT. PNL AR9 150Y 100A AP9 COMMUNICATION PLYWOOD PLYWOOD BUS 3 2 901-923 100A 100S GROUND 11 1 - 480/208V BUS 4" C n n n n ea #3/0 Cu ra (SEE SHEET E7.01) w O co w m 0� m 0 LL I - V- w O m U- ONE LINE DIAGRAM (LEVELS 9-19' SCALE: NONE LEVEL 19 LEVEL 18 LEVEL 17 LEVEL 16 LEVEL 15 LEVEL 14 LEVEL 13 LEVEL 12 LEVEL 11 LEVEL 10 REVIEWED.FOR COMPLIANCE WITH NFPA 70 - NEC LEVEL gPEC 0 3 2015 (SEE SHEET E7.01) City of-TukWila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 0 w Y z a3: O �2 W J pY V QH Z M N Z N U) CONSULTANT REGISTRATION /15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 8264446 SHEET TITLE AND NUMBER ONE LINE DIAGRAM (LEVELS 9-19) E7.02 H z w Of clrl �o ao o .. w 10 o04 r,� o� �o APARTMENT UNIT LOAD CALCULATION - METER CENTER (MC6) APARTMENT PANEL UNITTYPE AREA GENERAL LIGHTING LOAD MINIMUM WATTS REQD MAXIMUM WAS REQD H1 KW H2 KW H3 KW H4 KW HEATING KW TOTAL LOAD DW / GD WASHER/ DRYER SMALL APPLIANCE RANGE CONNECTED LOAD DEMAND LOAD DEMAND AMPS FEEDER SIZE 601 ST 339 1.017 760 1140 1.20 1.20 2.5 2 6.5 3 8 21,717 15.407 74.1 125 AMP 602 1-BR 474 1.422 1246 1869 1.50 0.75 2.25 2 2 6.5 3 8 23.172 16.619 79.9 125 AMP 603 ST 307 0.921 618 927 1.00 1.00 2.5 2 6.5 3 8 21.421 15.168 72.9 125 AMP 604 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 125 AMP 605 1-BR 565 1.695 989 1484 1.00 0.675 1.68 2.5 2 6.5 3 8 22.870 16.153 77.7 125 AMP 606 1-BR 541 1.623 989 1484 1.00 0.675 1.68 3 2 6.5 3 8 22.798 16.124 1 77.5 125 AMP 607 1-BR 565 1.695 989 1484 1.00 0.675 1.68 2.5 2 6.5 3 8 22.870 16.153 77.7 125 AMP 608 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 609 ST 306 0.918 618 927 1.00 1.00 1.5 2 6.5 3 8 21.418 15.167 72.9 125 AMP 610 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 611 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 612 1-BR 541 1.623 989 1484 1.00 0.675 1.68 1.5 2 6.5 3 8 22.798 16.124 77.5 125 AMP 613 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 615 1-BR 565 1.695 1036 1554 1.00 0.675 1.68 0 2 6.5 3 8 1 22.870 16.153 77.7 617 ST 307 0.921 618 927 1.00 1.00 2.5 2 6.5 3 8 21.421 15.168 72.9 125 AMP 618 2-BR 917 2.751 1363 2044 1.00 0.675 0.675 2.35 3 2 6.5 3 8 24.601 17.250 82.9 100 AMP 619 ST 307 0.921 618 1 927 1.00 1.00 2.5 2 6.5 3 8 21.421 15.168 72.9 125 AMP 621 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22,870 16.153 77.7 623 2-BR+DEN 884 2.652 1992 2988 1.00 1.00 1 0.75 0.75 3.50 0 2 6.5 1 3 8 25.652 18.361 88.3 SUBTOTAL 19 9210 27.630 29.700 38 124 57 152 427.830 162.575 451.6 701 ST 339 1.017 760 1140 1.20 1.20 2.5 2 6.5 3 8 21.717 15.407 74.1 100 AMP 702 1-BR 474 1.422 1246 1869 1.50 0.75 2.25 1.5 2 6.5 3 8 23.172 16.619 79.9 100 AMP 703 ST 307 0.921 618 927 1.00 1.00 2 2 6.5 3 8 21.421 15.168 72.9 100 AMP 704 1-BR 541 1.623 989 1484 1.00 0.675 1.68 1.5 2 6.5 3 8 22.798 16.124 77.5 100 AMP 705 1-BR 565 1.695 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.870 16.153 77.7 100 AMP 706 1-BR 541 1.623 989 1484 1.00 0.675 1.68 1.5 2 6.5 3 8 22.798 16.124 77.5 100 AMP 707 1-BR 565 1.695 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.870 16.153 77.7 100 AMP 708 ST 306 0.918 618 927 1.00 1.00 3 2 6.5 3 8 21.418 15.167 72.9 100 AMP 709 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 125 AMP 710 ST 306 0.918 618 927 1.00 1.00 2 2 6.5 3 8 21.418 15.167 72.9 100 AMP 711 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21,421 15.168 72.9 100 AMP 712 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 100 AMP 713 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AMP 715 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AMP 717 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 100 AMP 718 2-BR 727 2.181 1363 2044 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.031 17.022 81.8 100 AMP 719 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 100 AMP 721 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AMP 723 2-BR+DEN 884 2.652 1992 2988 1.00 1.00 0.75 0.75 3.50 0 2 6.5 3 8 25.652 18.361 88.3 125 AMP SUBTOTAL 19 9019 27.057 29.7 38 123.5 57 152 427.257 162.358 451.0 MC6 TOTAL 38 18229 54.687 69.4 76 247.0 114 304 855.087 247.975 688.8 APARTMENT UNIT LOAD CALCULATION - METER CENTER (MC8) APARTMENT PANEL UNIT TYPE AREA GENERAL LIGHTING LOAD MINIMUM READ MAXIMUMWATTS WATTS READ Ill KW H2 KW H3 KW H4 KW HEATING KW TOTAL LOAD DW / GD WASHER/ DRYER SMALL APPLIANCE RANGE CONNECTED LOAD DEMAND LOAD DEMAND AMPS FEEDER SIZE 801 ST 339 1.017 760 1140 1.20 1.20 2 2 1 6.5 3 8 21.717 15.407 74.1 100 AMP 802 1-BR 474 1.422 1246 1869 1.50 0.75 2.25 2 2 6.5 3 8 23.172 16.619 79.9 100 A M P 803 ST 307 0.921 618 927 1.00 1.00 2.5 2 6.5 3 8 21.421 15.168 72.9 100 AMP 804 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 100 AMP 805 1-BR 565 1.695 989 1484 1.00 0.675 1.68 2.5 2 6.5 3 8 22.870 16.153 77.7 100 AMP 806 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 100 AMP 807 1-BR 565 1.695 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.870 16.153 77.7 100 AMP 808 ST 306 0.918 618 927 1.00 1.00 2 2 6.5 3 8 21.418 15.167 72.9 100 AMP 809 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 125 AMP 810 ST 306 0.918 618 927 1.00 1.00 2 2 6.5 3 8 21.418 15.167 72.9 100 AMP 811 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 100 AMP 812 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 100 AMP 813 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AM P 815 1-BR 565 1.695 989 1484 1.00 0,675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AM P 817 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 100 AMP 818 2-BR 917 2.751 1363 2044 1.00 0.675 0.675 2.35 2 2 6.5 3 8 24.601 17.250 82.9 100 AM P 819 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 100 AMP 821 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AMP 823 2-BR+D 884 2.652 1992 2988 1.00 1.00 0.75 0.75 3.50 0 2 6.5 3 8 25.652 18.361 88.3 125 AMP SUBTOTAL 19 9209 27.627 29.7 38 123.5 57 152 427.827 162.574 451.6 901 ST 339 1.017 760 1140 1.20 1.20 2.5 2 6.5 3 8 21.717 15.407 74.1 100 AMP 902 1-BR 474 1.422 1246 1869 1.50 0.75 1 2.25 2 2 6.5 3 8 23.172 16.619 79.9 100 AMP 903 ST 307 0,921 618 927 1.00 1 1.00 2.5 2 6.5 3 8 21.421 15.168 72.9 100 AMP 904 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 100 AMP 905 1-BR 565 L695 989 1484 1.00 0.675 1,68 2.5 2 6.5 3 8 22.870 1&153 77.7 100 AMP 906 1-BR 541 1.623 989 1484 1.00 0.675 1.68 3 2 6.5 3 8 22.798 16.124 77.5 100 AMP 907 1-BR 565 1.695 989 140Y 1.00 0.675 1.68 2.5 2 6.5 3 8 22.870 16.153 77.7 100 AMP 908 ST 306 0.918 618 927 1,00 1.00 1.5 2 6.5 3 8 21.418 15.167 72.9 1100AMP 909 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 100 AMP 910 ST 306 0.918 618 927 1.00 1.00 1.5 2 6.5 3 8 21.418 15.167 72.9 100 AMP 911 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 100 AMP 912 1-BR 541 1.623 989 1484 1.00 0.675 1.68 1.5 2 6.5 3 8 22.798 16.124 77.5 100 AMP 913 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AMP 915 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AMP 917 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 100 AMP 918 2-BR 727 2.181 1363 2044 1.00 0.675 0.675 2.35 3 2 6.5 3 8 24.031 17.022 81.8 100 AMP 919 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 100 AMP 921 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AMP 923 2-BR+D 884 2.652 1992 2988 1.00 1.00 0.750 0.750 3.50 0 2 6.5 3 8 25.652 18.361 88.3 100 AMP SUBTOTAL 19 9019 27.057 29.7 38 123.5 57 152 427.257 162.358 451.0 MC8 TOTAL 38 18228 54.684 59.4 76 247.0 114 304 855.084 247.974 688.8 APARTMENT UNIT LOAD CALCULATION - METER CENTER (MCI 0) APARTMENT PANEL UNIT TYPE AREA GENERAL LIGHTING LOAD MINIMUM WATTS REQD MAXIMUM WATTS REQD H1 KW H2 KW H3 KW H4 KW HEATING KW TOTAL LOAD DW / GD WASHER/ DRYER SMALL APPLIANCE RANGE CONNECTED LOAD DEMAND LOAD DEMAND AMPS FEEDER SIZE 1001 ST 339 1.017 760 1140 1.20 1.20 2.5 2 6.5 3 8 21.717 15.407 74.1 100 AMP 1002 1-BR 474 1.422 1246 1869 1.50 0.75 2.25 1.5 2 6.5 3 8 23.172 16.619 79.9 100 AMP 1003 ST 307 0.921 618 927 1.00 1.00 2 2 6.5 3 8 21.421 15.168 72.9 100 AMP 1004 1-BR 541 1.623 989 1484 1.00 0.675 1.68 1.5 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1005 1-BR 565 1.695 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.870 16.153 77.7 100 AMP 1006 1-BR 541 1,623 989 1484 1.00 0.675 1.68 1.5 2 6.5 3 8 22.798 16.124 77.5 100 AM P 1007 1-BR 565 1.695 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.870 16.153 77.7 100 AM P 1008 ST 306 0.918 618 927 1.00 1.00 3 2 6.5 3 8 21.418 15.167 72.9 100 AMP 1009 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 100 AMP 1010 ST 306 0.918 618 927 1.00 1.00 2 2 6.5 3 8 21.418 15.167 72.9 100 AMP 1011 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 100 AMP 1012 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1013 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AMP 1015 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AMP 1017 ST 307 0,921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 100 AMP 1018 2-BR 727 2.181 1363 2044 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.031 17.022 81.8 100 AMP 1019 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21,421 15.168 72.9 100 AMP 1021 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AMP 1023 2-BR+D 884 2.652 1992 2988 1.00 1.00 0.75 0.75 3.50 0 2 6.5 3 8 25.652 18.361 88.3 100 AMP SUBTOTAL 19 9019 27.057 29.7 38 123.5 57 152 427.257 162.358 451.0 1101 ST 339 1.017 760 1140 1.20 1.20 2 2 6.5 3 .8 21.717 15.407 74.1 100 AMP 1102 1-BR 474 1.422 1246 1869 1.50 0.75 2.25 2 2 6.5 3 8 23.172 16.619 79.9 100 AMP 1103 ST 307 0.921 618 927 1.00 1.00 2.5 2 6.5 3 8 21.421 15.168 72.9 100 AMP 1104 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1105 1-BR 565 1.695 989 1484 1.00 0.675 1.68 2.5 2 6.5 3 8 22.870 16.153 77.7 100 AMP 1106 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1107 1-BR 565 1.695 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.870 16.153 77.7 100 AMP 1108 ST 306 0.918 618 927 1.00 1.00 2 2 6.5 3 8 21.418 15.167 72.9 100 AMP 1109 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 1 15.168 72.9 100 AMP I I lu a71 Ju0 U..710 - 010 - .741 A - I.uu A AA I.Uu n G n L G L- u.:J 7 J O O n4 A40 L1.-+Iu 4G 4C� IJ. Iu/ �9 (1 /L..7 4^^ ARAM IvvIn r- 1111 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 100 AMP 1112 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1113 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AMP 1115 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AMP 1117 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15,168 72.9 100AMP 1118 2-BR 727 2.181 1363 2044 1.00 0.675 0.675 2.35 2 2 6.5 3 8 24.031 17.022 81.8 100 AMP 1119 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 100 AMP 1121 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 100 AMP 1123 2-BR+D 884 2.652 1992 2988 1.00 1.00 0.75 0.75 3.50 0 2 6.5 3 8 25.652 18.361 88.3 100 AMP SUBTOTAL 19 9019 27.057 29.7 38 123.5 57 152 427.257 162.358 451.0 MC10 TOTAL 38 18038 54.114 59.4 76 247.0 114 304 854.514 247.809 688.4 APARTMENT UNIT LOAD CALCULATION - TOTAL SUMMARY (208V13-PH) METER CENTER TOTAL UNITS AREA GENERAL LIGHTING LOAD HEATING KW DW / GD WASHER/ DRYER SMALL APPLIANCE RANGE CONNECTED LOAD DEMAND LOAD DEMAND AMPS FEEDER SIZE MC3 32 14387 43 54.03 64 208 96 256 721.186 223.568 621.0 800 AMP MC4 38 17910 53.73 59.40 76 247 114 304 854.130 247.698 688.0 800 AMP MC6 38 18229 54.687 59.40 76 247 114 304 855.087 247.975 688.8 800 AMP MC8 38 18228 54.684 59.40 76 247 114 304 855.084 247.974 688.8 800 AMP MC10 38 18038 54.114 59.40 76 247 114 304 854.514 247.809 688.4 800 AMP MC12 33 15872 47.616 51.00 66 214.5 99 264 742.116 230.056 639.0 800 AMP MC13 28 15761 47.283 49.38 56 182 84 224 642.658 212.077 589.1 800 AMP MC14 28 15781 47.343 49.38 56 182 84 224 642.718 212.097 589.2 800 AMP MC15 28 15808 47.424 49.38 56 182 84 224 642.799 212.124 589.2 800 AMP MC16 28 15782 47.346 49.38 56 182 84 224 642.721 212.098 589.2 800 AMP MC17 28 15283 45.849 59.00 56 182 84 224 650.849 214.780 596.6 800 AMP MC18 14 15731 47.193 45.20 28 91 42 112 365.393 179.107 497.5 800 AMP MC SUBTOTAL 371 196810 590.430 644.3 742.0 2411.5 1113.0 2968.0 8469.3 1940.350 5389.9 HTL PNL HP19 33.140 32.950 158.4 TOTAL 371 196810 590.430 644.3 742.0 2411.5 1113.0 2968.0 8502.395 1973.300 5481.4 APARTMENT UNIT LOAD CALCULATION - METER CENTER (MC3) APARTMENT PANEL UNITTYPE AREA GENERAL LIGHTING LOAD MINIMUM WATTS REQD MAXIMUM WATTS REQD H1 KW H2 KW H3 KW H4 KW HEATING KW TOTAL LOAD DW / GD WASHER/ DRYER SMALL APPLIANCE RANGE CONNECTED LOAD DEMAND LOAD DEMAND AMPS FEEDER SIZE 201 ST 338 1.014 1077 1616 2.00 2.00 1.5 2 6.5 3 8 22.514 16.206 77.9 125 AMP 202 ST 437 1.311 871 1306 1.50 1.50 3 2 6.5 3 8 22.311 15.824 76.1 100 AMP 203 ST 308 0.924 852 1278 1.50 1.50 1.5 2 6.5 3 8 21.924 15.670 75.3 125 AMP 205 1-BR 548 1.644 1447 2171 1.50 1.00 2.50 1.5 2 6.5 3 8 23.644 16.958 81.5 125 AMP 207 1-BR 548 1.644 1447 2171 1.50 1.00 2.50 3 2 6.5 3 8 23.644 16.958 81.5 125 AMP 209 ST 308 0.924 851 1277 1.50 1.50 2 2 6.5 3 8 21.924 15.670 75.3 125 AMP 211 ST 308 0.924 851 1277 1.50 1.50 2 2 6.5 3 8 21.924 15.670 75.3 100 AMP 213 1-BR 548 1.644 1446 2169 1.50 1.00 2.50 0 2 6.5 3 8 23.644 16.958 81.5 100 AMP 215 1-BR 548 1.644 1446 2169 1.50 1.00 2.50 0 2 6.5 3 8 23.644 16.958 81.5 100 AMP 217 ST 308 0.924 852 1278 1.50 1.50 0 2 6.5 3 8 21.924 15.670 75.3 100 AMP 219 ST 308 0.924 852 1278 1.50 1.50 0 2 6.5 3 8 21.924 15.670 75.3 100 AMP 221 1-BR 548 1.644 1447 2171 1.50 1.00 2.50 0 2 6.5 3 8 23.644 16.958 81.5 100 AMP 223 1-BR 548 1.644 1447 2171 1.50 1.00 2.50 0 2 6.5 3 8 23.644 16.958 81.5 100 AMP SUBTOTAL 13 5603 16.809 26.0 26 85 39 104 296.309 121.487 337.5 301 ST 338 1.014 760 1140 1.20 1.20 3 2 6.5 3 8 21.714 15.406 74.1 125 AMP 302 ST 442 1.326 920 1380 1.50 1.50 2 2 6.5 3 8 22.326 15.830 76.1 125 AMP 303 ST 309 0,927 618 927 1.00 1.00 1.5 2 6,5 3 8 21.427 15.171 72.9 125 AMP 304 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 125 AMP 305 1-BR 543 1,629 989 1484 1.00 0.675 1.68 1.5 2 6.5 3 8 22.804 16.127 77.5 125 AMP 306 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2.5 2 6.5 3 8 22.798 16.124 77.5 125 AMP 307 1-BR 543 1.629 989 1 1484 1.00 0.675 1.68 1.5 1 2 6.5 3 8 22.804 16.127 77.5 100 AMP 308 ST 306 0,918 618 927 1.00 1.00 2.5 2 6.5 3 8 21.418 15.167 72.9 125 AMP 309 ST 306 0.918 618 927 1.00 1.00 0 2 6.5 3 8 21.418 15.167 72.9 310 ST 306 0.918 618 927 1.00 1.00 2.5 2 6.5 3 8 21.418 15.167 72.9 125 AMP 311 ST 306 0.918 618 927 1.00 1.00 0 2 6.5 3 8 21.418 15.167 72.9 312 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2.5 2 6.5 3 8 22.798 16.124 77.5 125 AMP 313 1-BR 543 1.629 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.804 16.127 77.5 315 1-BR 543 1.629 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.804 16.127 7T5 317 ST 306 0.918 618 927 1.00 1.00 0 2 6.5 3 8 21.418 15.167 72.9 318 1-BR 660 1.980 1036 1554 1.00 0.675 1.68 2.5 2 6,5 3 8 23.155 16.267 78.2 100 AMP 319 ST 306 0.918 618 927 1.00 1.00 0 2 6.5 3 8 21.418 15.167 72.9 321 1-BR 543 1.629 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.804 16.127 77.5 323 2-BR+DEN 861 2.583 1828 2741 1.00 0.75 0.75 0.75 3.25 0 2 6.5 3 8 25.333 18.083 86.9 SUBTOTAL 19 8784 26.352 28 38 124 57 152 424.877 161.453 448.5 MC3 TOTAL 32 14387 43 54 64 208 96 256 721.186 223.568 621.0 APARTMENT UNIT LOAD CALCULATION - METER CENTER (MC4) APARTMENT PANEL UNITTYPE TAREA GENERAL LIGHTING LOAD MINIMUM WATTS REQD MAXIMUM WATTS REQD H1 KW H2 KW - H3 KW H4 KW HEATING KW TOTAL LOAD DW / GD WASHER! DRYER SMALL APPLIANCE RANGE CONNECTED LOAD DEMAND LOAD DEMAND AMPS FEEDER SIZE 401 ST 339 1.017 760 1140 1.20 1 1.20 2 2 6.5 3 8 21.717 15.407 74.1 125 AMP 402 1-BR 472 1.416 1246 1869 1.50 1 0.75 2.25 2 2 6.5 3 8 23.166 16.616 79.9 125 AMP 403 ST 306 0.918 618 927 1.00 1.00 2 2 6.5 3 8 21.418 15.167 72.9 125 AMP 404 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 125 AMP 405 1-BR 543 1.629 989 1484 1.00 0.675 1 1.68 2 2 6.5 3 1 8 22.804 16.127 77.5 125 AMP 406 1-BR 543 1.629 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.804 16.127 77.5 125 AMP 407 1-BR 543 1.629 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.804 16.127 77.5 125 AMP 408 ST 310 0.930 618 927 1.00 1 1.00 2 2 6.5 3 8 21.430 15.172 72.9 125 AMP 409 ST 306 0.918 618 927 1.00 1.00 0 2 6.5 3 8 21.418 15.167 72.9 410 ST 310 0.930 618 927 1.00 1.00 2 2 6.5 3 8 21.430 15.172 72.9 125 AMP 411 ST 306 0.918 618 927 1.00 1.00 0 2 6.5 3 8 21.418 15.167 72.9 412 1-BR 543 1.629 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.804 16.127 77.5 125 AMP 413 1-BR 543 1.629 989 1484 1.00 0,675 1.68 0 2 6.5 3 8 22.804 16.127 77.5 415 1-BR 543 1.629 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.804 16.127 77.5 417 ST 306 0,918 618 927 1.00 1.00 0 2 6.5 3 8 21.418 15.167 72.9 418 2-BR 727 2.181 1363 2044 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.031 17.022 81.8 100 AMP 419 ST 306 1 0.918 618 927 1.00 1.00 0 2 6.5 3 8 21.418 15.167 72.9 421 1-BR 543 1.629 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.804 16.127 77.5 423 2-BR+DEN 861 2.583 1992 2988 1.00 1.00 0.76 0.75 3.50 0 2 6.5 3 8 25.583 18.333 88.1 SUBTOTAL 19 8891 27 30 38 124 57 152 426.873 162.212 450.6 501 ST 339 1.017 760 1140 1.20 1.20 2 2 6.5 3 8 21.717 15.407 74.1 125 AMP 502 1-BR 474 1.422 1246 1869 1.50 0.75 2.25 1.5 2 6.5 3 8 23.172 16.619 79.9 125 AMP 503 ST 307 0.921 618 927 1.00 1.00 1.5 2 6.5 3 8 21.421 15.168 72.9 125 AMP 504 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 125 AMP 505 1-BR 565 1.695 989 1484 1.00 0.675 1.68 2.5 2 6.5 3 8 22.870 16.153 77.7 125 AMP 506 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 125 AMP 507 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 508 ST 306 0.918 618 927 1.00 1.00 2 2 6.5 3 8 21.418 15.167 72.9 125 AMP 509 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 510 ST 306 0.918 618 927 1.00 1.00 2.5 2 6.5 3 8 21.418 15.167 72.9 125 AMP 511 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 512 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2.5 2 6.5 3 8 22.798 16.124 77.5 125 AMP 513 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 515 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 517 ST 307 0.921 618 927 1.00 1.00 0 2 6.5 3 8 21.421 15.168 72.9 518 2-BR 727 2.181 1363 2044 1.00 0.675 0.675 2.35 2 2 6.5 3 8 24.031 17.022 81.8 100 AMP 519 ST 307 0.921 618 927 1.00 1.00 0 1 2 6.5 3 8 21.421 15.168 72.9 521 1-BR 565 1.695 989 1484 1.00 0.675 1.68 0 2 6.5 3 8 22.870 16.153 77.7 523 2-BR+DEN 884 2.652 1992 2988 1.00 1.00 0.75 0.75 3.50 3 2 6.5 3 8 25.652 18.361 88.3 125 AMP SUBTOTAL 19 9019 27 29.7 38 123.5 57 152 427.257 162.358 451.0 MC4 TOTAL 38 17910 53.73 59.4 L-7.6:j 247 114 304 854.1 247.698 688.0 REVIEWED.FUI= COMPLIANCE WITH. NFPA 70 - NEC DEC 0 3 2015 City of•Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER CAC INDEX CALC NAME CALC NAME MC6 i SUMMARY MC8 MC3 MC10 MC4 SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry O� Y CL O > -, I � pY V Z M~ I I � 1 N i I I j U Z U W W 0 Z i M ;w CD i Z � W w U3 Lu F- � ti Cn U) d-j 0 WIZ LL. CD cm _ o 0 U) � e m ai W cm0cm r-fD � < Lo Lo i - 04 r N N REGISTRATION ST _ cr ti 1 - r0:�.1L % i 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER APARTMENT LOAD CALC E7.03 APARTMENT UNIT LOAD CALCULATION - METER CENTER (IVIC16) APARTMENT PANEL UNITTYPE AREA GENERAL LIGHTING LOAD MINIMUM WATTS REQD MAXIMUM WATTS REQD H1 KW H2 KW .....l H3 I KW H4 KW HEATING KW TOTAL LOAD DW / GD WASHER/ DRYER SMALL APPLIANCE RANGE CONNECTED LOAD DEMAND LOAD DEMAND AMPS FEEDER SIZE 1601 ST 339 1.017 760 1140 1.20 1.20 2.5 2 6.5 3 8 21.717 15.407 74.1 100 AMP 1602 1-BR 474 1.422 1246 1869 1.50 0.75 2.25 2 2 6.5 3 8 23.172 16.619 79.9 100 AMP 1603 2-BR 869 2.607 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.457 17.193 82.7 100 AMP 1604 1-BR 541 1.623 988 1482 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1606 1-BR 541 1.623 988 1482 1.00 0.675 1.68 3 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1607 2-BR+D 869 2.607 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.457 17.193 82.7 100 AMP 1608 ST 306 0.918 618 927 1.00 1 1.00 1.5 2 6.5 3 8 21.418 15.167 72.9 100 AMP 1610 ST 306 0.918 618 927 1.00 1.00 1.5 2 6.5 3 8 21.418 15.167 72.9 100 AMP 1611 2-BR+D 869 2.607 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.457 17.193 82.7 100 AMP 1612 1-BR 541 1.623 988 1482 1.00 0.675 1.68 1.5 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1615 2-BR+D 869 2.607 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24A57 17.193 82.7 100 AMP 1618 2-BR 727 2.181 1363 2044 1.00 0.675 0.675 2.35 3 2 6.5 3 8 24.031 17.022 81.8 100 AMP 1619 2-BR+D 869 1 2.607 1378 2068 1.00 0.675 0.675 2.35 1 2 2 6.5 1 3 8 24.457 17.193 82.7 100 AMP 1623 2-BR+D 884 2.652 1992 2988 1.00 1.00 0.75 0.75 3.50 2 2 6.5 3 8 25.652 18.361 88.3 100 AMP 1625 1-BR 559 1.677 1256 1883 1.50 0.75 2.25 3 2 6.5 3 8 23.427 16.721 80.4 100 AMP 1626 1-BR 672 2.016 1003 1505 1.00 0.75 1.75 1.5 2 6.5 3 8 23.266 16.356 78.6 100 AMP 1627 1-BR 663 1.989 1003 1505 1.00 0.75 1.75 1.5 2 6.5 3 8 23.239 16.346 78.6 100 AMP 1628 ST 324 0.972 618 927 1.00 1.00 1.5 2 6.5 3 8 21.472 15.189 73.0 100 AMP 1629 ST 357 1.071 618 927 1.00 1.00 2.5 2 6.5 3 8 21.571 15.228 73.2 100 AMP 1630 ST 324 0.972 618 927 1.00 1.00 2 2 6.5 3 8 21.472 15.189 73.0 100 AMP 1631 ST 357 1.071 618 927 1.00 1.00 2 2 6.5 1 3 8 21.571 15.228 73.2 100 AMP 1632 1-BR 572 1.716 988 1482 1.00 0.675 1.68 3 2 6.5 3 8 22.891 16.161 77.7 100 AMP 1633 1-BR 617 1.851 988 1482 1.00 0.675 1.68 1.5 2 6.5 3 8 23.026 16.215 78.0 100 AMP 1634 1-BR+D 577 1.731 1009 1514 1.00 0.75 1.75 1.5 2 6.5 3 8 22.981 16.242 78.1 100 AMP 1635 ST 357 1.071 618 927 1.00 1.00 1.5 2 6.5 3 8 21.571 15.228 73.2 100 AMP 1636 1-BR 465 1.395 1267 1900 1.50 0.75 2.25 3 2 6.5 3 8 23.145 16.608 79.8 1100AMP 1637 ST 356 1.068 618 927 1.00 1.00 2 2 6.5 3 8 21.568 15.227 73.2 100 AMP 1639 1-BR 578 1.734 1267 1900 1.20 1.00 2.20 0 2 6.5 3 8 23.434 16.694 80.3 MC16 TOTAL 28 16782 47.346 49.4 56 182 84 224 642.721 212.098 589.2 APARTMENT UNIT LOAD CALCULATION - METER CENTER (MC17) APARTMENT PANEL UNITTYPE AREA GENERAL LIGHTING LOAD MINIMUM WATTS REQD MAXIMUM WATTS REQD H1 KW H2 KW I H3 KW I H4 KW HEATING KW TOTAL LOAD -L DW / GD WASHER/ DRYER SMALL APPLIANCE RANGE CONNECTED LOAD DEMAND LOAD DEMAND AMPS FEEDER SIZE 1701 ST 339 1.017 890 1334 1.50 1.50 2 2 6.5 3 8 22.017 15.707 75.5 125 AMP 1702 1-BR 452 1.356 1483 2225 1.50 1.20 2.70 2 2 6.5 3 8 23.556 17.042 81.9 125 AMP 1703 2-BR+D 824 2.472 1700 2550 1.20 1.000 0.750 2.95 2.5 2 6.5 3 8 24.922 17.739 85.3 125 AMP 1704 1-BR 541 1.623 1202 1802 1.20 0.750 1.95 2 2 6.5 3 8 23.073 16.399 78.8 125 AMP 1706 1-BR 541 1.623 1202 1802 1.20 0.750 1.95 2 2 6.5 3 8 23.073 16.399 78.8 125 AMP 1707 2-BR+D 824 2.472 1700 2550 1.20 1.000 0.750 2.95 2.5 2 6.5 3 8 24.922 17.739 85.3 125 AMP 1708 ST 306 0.918 726 1090 1.20 1.20 2 2 6.5 3 8 21.618 15.367 73.9 125 AMP 1710 ST 306 0.918 726 1090 1.20 1.20 2 2 6.5 3 8 21.618 15.367 73.9 125 AMP 1711 2-BR+D 824 2.472 1700 2550 1.20 1.000 0.750 2.95 3 2 6.5 3 8 24.922 17.739 85.3 125 AMP 1712 1-BR 541 1.623 1202 1802 1.20 0.750 1.95 2 2 6.5 3 8 23.073 16.399 78.8 125 AMP 1715 2-BR+D 824 2.472 1700 2550 1.20 1.000 0.750N0.7 2.95 1.5 2 6.5 3 8 24.922 17.739 85.3 125 AMP 1718 2-BR 726 2.178 1682 2523 1.20 1.000 0.7502.95 2 2 6.5 3 8 24.628 17.621 84.7 125 AMP 1719 2-BR+D 856 2.568 1700 2550 1.20 1.000 0.7502.95 1.5 2 6.5 3 8 25.018 17.777 85.5 125 AMP 1723 2-BR+D 861 2.583 2203 3305 1.50 1.00 0.75 4.00 1.5 1 2 6.5 3 8 1 26.083 18.833 90.5 125 AMP 1725 1-BR 548 1.644 1518 2277 1.50 1.00 1 2.50 2.5 2 6.5 3 8 23.644 16.958 81.5 125 AMP 1726 1-BR 672 2.016 1219 1828 1.20 0.75 1.95 2 2 6.5 3 8 23.466 16.556 79.6 125 AMP 1727 1-BR 598 1.794 1219 1828 1.20 0.75 1.95 2 2 6.5 3 8 23.244 16.468 79.2 125 AMP 1728 ST 324 0.972 7-26 1090 1.20 1.20 0 2 6.5 3 1 8 21.672 15.389 74.0 125 AMP 1729 ST 324 0.972 726 1090 1.20 1.20 1 0 2 6.5 3 8 21.672 15.389 74.0 1125AMP 1730 ST 324 0.972 726 1090 1.20 1 1.20 0 2 6.5 3 8 21.672 15.389 74.0 125 AMP 1731 ST 324 0.972 726 1090 1.20 1.20 2 2 6.5 3 8 21.672 15.389 74.0 125 AMP 1732 1-BR 572 1.716 1202 1802 1.20 0.750 1.95 2 2 6.5 3 8 23.166 16.436 79.0 125 AMP 1733 1-BR 573 1.719 1202 1802 1.20 0.750 1.95 2 2 6.5 3 8 23.169 16.438 79.0 125 AMP 1734 1-BR+D 579 1.737 1226 1838 1.20 0.75 1.95 1 1.5 2 6.5 3 8 23.187 16.445 79.1 125 AMP 1735 ST 324 0.972 726 1090 1.20 1 1.20 2 2 6.5 3 8 21.672 15.389 74.0 125 AMP 1736 1-BR 454 1.362 1488 2232 1.50 1.20 1 2.70 1.5 2 6.5 3 8 23.562 17.045 81.9 125 AMP 1737 ST 324 0.972 726 1090 1.20 1 1.20 0 2 6.5 3 8 21.672 15.389 74.0 1739 1-BR 578 1.734 1488 2232 1.50 1.20 2.70 0 2 6.5 3 8 23.934 17.194 82.7 MCI TOTAL 28 15283 46.849 59.0 56 182.0 84 224 650.849 214.780 596.6 APARTMENT UNIT LOAD CALCULATION - METER CENTER (MC18) APARTMENT PANEL UNITTYPE AREA GENERAL LIGHTING LOAD MINIMUM WATTS REQD MAXIMUM' WATTS REQD H1 KW H2 KW H3 KW H4 KW HEATING KW TOTAL LOAD DW/ GD WASHER/ DRYER SMALL APPLIANCE RANGE CONNECTED LOAD DEMAND LOAD DEMAND AMPS FEEDER SIZE 1801 3-BR+D CRNER 1767 5.301 3810 5715 5.3 5.30 2 2 6.5 1 3 8 30.101 21.220 1 102.0 125 AMP 1804 1-BR 541 1.623 1203 1804 1.4 1.40 1.5 2 6.5 3 8 22.523 15.849 76.2 125 AMP 1806 1-BR 541 1.623 1431 2146 1.4 1.40 2 2 6.5 1 3 8 22.523 15.849 76.2 125 AMP 1808 2-BR+D 1103 3.309 2436 3655 2.5 2.50 2 2 6.5 3 8 25.309 17.624 84.7 125 AMP 1809 3-BR+D 1718 5.154 3443 5165 5.3 5.30 1 1.5 2 6.5 3 8 29.954 21.162 101.7 125 AMP 1818 2-BR 727 2.181 1682 2523 2.3 2.30 2 2 6.5 3 8 23.981 16.972 81.6 125 AMP 1819 3-BR+D 1719 5.157 2718 4078 4.8 4.80 2.5 2 6.5 3 8 29.457 20.663 99.3 125 AMP 1823 2-BR+D 860 2.580 2253 3379 3.2 3.20 3 2 6.5 3 8 25.280 18.032 86.7 125 AMP 1825 2-BR+D 1238 3.714 12262 3392 3.2 3.20 2 2 6.5 3 8 26.414 18.486 88.9 125 AMP 1826 1-BR 672 2.016 1 1213 1820 2.3 2.30 1 2 2 6.5 1 3 8 23.816 16.906 81.3 125 AMP' 1828 2-BR+D 1250 3.750 1964 2946 3.2 3.20 2 2 6.5 3 8 26.450 18.500 88.9 1125AMP 1829 2-BR+D 1247 3.741 1964 2946 3.2 3.20 2 2 6.5 3 8 26.441 18.496 88.9 125 AMP 1834 1-BR+D 577 1.731 1377 2066 2.3 2.30 0 2 6.5 3 8 23.531 16.792 80.7 125 AMP 1839 3-BR+D CRNER 1771 5.313 3115 4673 4.8 4.80 2 2 6.5 3 8 1 29.613 20.725 99.6 125 AMP SUBTOTAL 14 15731 47.193 45.2 28.0 91.0 42.0 112.0 365.4 146.157 406.0 HTL PNL HP19A 36.722 35.508 170.7 MC18 TOTAL 14 15731 47.193 45.2 28.0 91.0 42.0 112.0 402.115 181.665 504.6 APARTMENT UNIT LOAD CALCULATION - METER CENTER (MC12) APARTMENT PANEL UNIT TYPE AREA GENERAL LIGHTING LOAD MINIMUM REQD MAXIMUMWATTS WATTS REQD H1 KW H2 KW H3 KW H4 KW HEATING KW TOTAL LOAD DW / GD WASHER/ DRYER SMALL APPLIANCE RANGE CONNECTED LOAD DEMAND LOAD DEMAND AMPS FEEDER SIZE 1201 ST 339 1.017 760 1140 1.20 1.20 2.5 2 6.5 3 8 21.717 15.407 74.1 100 AMP 1202 1-BR 474 1.422 1246 1869 1.50 0.75 2.25 2 2 6.5 3 8 23.172 16.619 79.9 100 AMP 1203 ST 307 0.921 618 927 1.00 1.00 2.5 2 6.5 3 8 21.421 15.168 72.9 100 AMP 1204 1-BR 541 1.623 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1205 1-BR 565 1.695 989 1484 1.00 0.675 1.68 2.5 2 6.5 3 8 22.870 16.153 77.7 100 AMP 1206 1-BR 541 1.623 989 1484 1.00 0.675 1.68 3 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1207 1-BR 565 1.695 989 1484 1.00 0.675 1.68 2.5 2 6.5 3 8 22.870 16.153 77.7 100 AMP 1208 ST 306 0.918 618 927 1.00 1.00 1.5 2 6.5 3 8 21.418 15.167 72.9 100 AMP 1209 ST 307 0.921 618 927 1.00 1.00 2.5 2 6.5 3 8 21.421 15.168 72.9 100 AMP 1210 ST 306 0.918 618 927 1.00 1.00 1.5 2 6.5 3 8 21.418 15.167 72.9 100 AMP 1211 ST 307 0.921 618 927 1.00 1.00 2 2 6.5 3 8 21.421 15.168 72.9 100 AMP 1212 1-BR 541 1.623 989 1484 1.00 0.675 1.68 1.5 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1213 1-BR 565 1.695 989 1484 1.00 0.675 1.68 2 2 6.5 3 8 22.870 16.153 77.7 100 AMP 1215 1-BR 565 1.695 989 1484 1.00 0.675 1.68 3 2 6.5 3 8 22.870 16.153 77.7 100 AMP 1217 ST 307 0.921 618 927 1.00 1.00 1.5 2 6.5 3 8 21.421 15.168 72.9 100 AMP 1218 2-BR 727 2.181 1363 2044 1.00 0.675 0.675 2.35 3 2 6.5 3 8 24.031 17.022 81.8 100 AMP 1219 ST 307 0.921 618 927 1.00 1.00 1.5 2 6.5 3 8 21.421 15.168 72.9 100 AMP 1221 1-BR 565 1.695 989 1484 1.00 0.675 1.68 1.5 2 6.5 3 8 22.870 16.153 77.7 100 AMP 1223 2-BR+D 884 2.652 1992 2988 1.00 1.00 0.75 0.75 3.50 2.5 2 1 6.5 3 8 25.652 18.361 88.3 100 AMP 1225 1-BR 559 1.677 1256 1883 1.50 0.75 2.25 2 2 1 6.5 3 8 23.427 16.721 80.4 100 AMP 1226 1-BR 672 2.016 1008 1513 1.00 0.75 1.75 2 2 6.5 3 8 23.266 16.356 78.6 100 AMP 1227 1-BR 663 1.989 1008 1513 1.00 0.75 1.75 3 2 6.5 3 8 23.239 16.346 78.6 100 AMP 1228 ST 1 324 0.972 618 927 1.00 1.00 1.5 2 6.5 3 8 21.472 15.189 73.0 100 AMP 1229 ST 357 1.071 618 927 1.00 1.00 1.5 2 6.5 3 8 21.571 15.228 73.2 100 AMP 1230 ST 324 0.972 618 927 1.00 1.00 1.5 2 6.5 3 8 21.472 15.189 73.0 100 AMP 1231 ST 356 1.068 618 927 1.00 1.00 3 2 6.5 3 8 21.568 15.227 73.2 100 AMP 1232 1-BR 572 1.716 988 1482 1.00 0.675 1.68 2 2 6.5 3 8 22.891 16.161 77.7 100 AMP 1233 1-BR 573 1.719 988 1482 1.00 0.675 1.68 2 2 6.5 3 8 22.894 16.163 77.7 100 AMP 1234 1-BR+D 578 1.734 1009 1514 1.00 0.75 1.75 2.5 2 6.5 3 8 22.984 16.244 78.1 100 AMP 1235 ST 356 1.068 618 927 1.00 1.00 2.5 2 6.5 3 8 21.568 15.227 73.2 100 AMP 1236 ST NW CORNER 585 1.755 1266 1898 1.50 0.75 2.25 2.5 2 6.5 3 8 23.505 16.752 80.5 100 AMP 1237 ST 356 1.068 618 927 1.00 1.00 2.5 2 6.5 3 8 21.568 15.227 73.2 100 AMP 1239 1-BR 578 1.734 1266 1898 1.20 1.00 2.20 2.5 2 6.5 3 8 23.434 16.694 80.3 100 AMP MC12 TOTAL 33 15872 47.616 51.0 66 214.5 99 264 742.116 230.056 639.0 APARTMENT UNIT LOAD CALCULATION - METER CENTER (MC13) APARTMENT PANEL UNIT TYPE AREA GENERAL LIGHTING LOAD MINIMUM WATTS REQD MAXIMUM WATTS REQD H1 KW H2 KW H3 KW H4 KW HEATING KW TOTAL LOAD DW / GD WASHER/ DRYER SMALL APPLIANCE RANGE CONNECTED LOAD DEMAND LOAD DEMAND AMPS FEEDER SIZE 1301 ST 339 1.017 760 1140 1.20 1.20 2 2 6.5 3 8 21.717 15.407 74.1 100 AMP 1302 1-BR 474 1.422 1246 1869 1.50 0.75 2.25 2 2 6.5 3 8 23.172 16.619 79.9 100 AMP 1303 2-BR+D 870 2.610 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.460 17.194 82.7 100 AMP 1304 1-BR 541 1.623 989 1484 1.00 0.675 1.68 3 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1306 1-BR 541 1.623 989 1484 1.00 0.675 1.68 1.5 2 6.5 3 8 22.798 16.124 77.5 100 AM P 1307 2-BR+D 869 2.607 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.457 17.193 82.7 100 AMP 1308 ST 306 0.918 618 927 1.00 1.00 1.5 2 6.5 3 8 21.418 15.167 72.9 100 AMP 1310 ST 305 0.915 618 927 1.00 1.00 1.5 2 6.5 3 8 21.415 15.166 72.9 100 AMP 1311 2-BR+D 869 2.607 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.457 17.193 82.7 100 AMP 1312 1-BR 541 1.623 989 1484 1.00 0.675 1.68 3 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1315 2-BR+D 869 2.607 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.457 17.193 82.7 100 AMP 1318 2-BR 727 2.181 1363 2044 1.00 0.675 0.675 2.35 2 2 6.5 3 8 24.031 17.022 81.8 100 AMP 1319 2-BR+D 896 2.688 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.538 17.225 82.8 100 AMP 1323 2-BR+D 884 2.652 1992 2988 1.00 1.00 0.75 0.75 3.50 2 2 6.5 3 8 25.652 18.361 88.3 100 AMP 1325 1-BR 559 1.677 1256 1883 1.50 0.75 2.25 2 2 6.5 3 8 23.427 16.721 80.4 100 AMP 1326 1-BR 671 2.013 1003 1505 1.00 0.75 1.75 3 2 6.5 3 8 23.263 16.355 78.6 100 AMP 1327 1-BR 662 1.986 1003 1505 1.00 0.75 1.75 1.5 2 6.5 3 8 23.236 16.344 78.6 100 AMP 1328 ST 324 0.972 618 927 1.00 1.00 1.5 2 6.5 3 8 21.472 15.189 73.0 100 AMP 1329 ST 357 1.071 618 927 1.00 1.00 1.5 2 6.5 3 8 21.571 15.228 73.2 100 AMP 1330 ST 324 0.972 618 927 1.00 1.00 2.5 2 6.5 3 8 21.472 15.189 73.0 100 AMP 1331 ST 356 1.068 618 927 1.00 1.00 2 2 6.5 3 8 21.568 15.227 73.2 100 AMP 1332 1-BR 572 1.716 988 1482 1.00 0.675 1.68 3 2 6.5 3 8 22.891 16.161 77.7 100 AMP 1333 1-BR 573 1.719 988 1482 1.00 0.675 1.68 1.5 2 6.5 3 8 22.894 16.163 77.7 100 AMP 1334 1-BR+D 577 1.731 1009 1514 1.00 0.75 1.75 1.5 2 6.5 3 8 22.981 16.242 78.1 100 AMP 1335 ST 356 1.068 618 927 1.00 1.00 1.5 2 6.5 3 8 21.568 15.227 73.2 100 AMP 1336 1-BR 465 1.395 1267 1900 1.50 0.75 2.25 2.5 2 6.5 3 8 23.145 16.608 79.8 100 AMP 1337 ST 356 1.068 618 927 1.00 1.00 2 2 6.5 3 8 21.568 15.227 73.2 100 AMP 1339 1-BR 578 1.734 1267 1900 1.20 1.00 2.20 0 2 6.5 3 8 23.434 16.694 80.3 MCI TOTAL 28 15761 47.283 - i 1 -1 49.4 i1 56 182 L84 224 642.658 212.077 589. APARTMENT UNIT LOAD CALCULATION - METER CENTER (MC14) APARTMENT PANEL UNITTYPE AREA GENERAL LIGHTING LOAD MINIMUM WATTS REQD MAXIMUM WATTS REQD H1 KW H2 KW H3 KW H4 KW HEATING KW TOTAL LOAD DW / GD WASHER/ DRYER SMALL APPLIANCE RANGE CONNECTED LOAD DEMAND LOAD DEMAND AMPS FEEDER SIZE 1401 ST 339 1.017 760 1140 1 1.20 1 1 1 1.20 2.5 2 6.5 3 8 21.717 15.407 74.1 100 AMP 1402 1-BR 474 1.422 1246 1869 1.50 0.75 1 1 2.25 2 2 6.5 3 8 23.172 16.619 79.9 100 AMP 1403 2-BR+D 869 2.607 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.457 17.193 82.7 100 AMP 1404 1-BR 541 1.623 988 1482 1.00 0.675 1.68 2 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1406 1-BR 541 1.623 988 1482 1.00 0.675 1.68 3 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1407 2-BR+D 869 2.607 1378 2068 1.00 1 0.675 0.675 2.35 2.5 2 6.5 3 8 24.457 17.193 82.7 100 AMP 1408 ST 306 0.918 618 927 1.00 1.00 1.5 2 6.5 3 8 21.418 15.167 72.9 100 AMP 1410 ST 306 0.918 618 927 1.00 1 1.00 1.5 2 6.5 3 8 21.418 15.167 72.9 100 AMP 1411 2-BR+D 869 2.607 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.457 17.193 82.7 100 AMP 1412 1-BR 541 1.623 988 1482 1.00 0.675 1.68 1.5 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1415 2-BR+D 870 2.610 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.460 17.194 82.7 100 AMP 1418 2-BR 727 2.181 1363 2044 1.00 0.675 0.675 2.35 3 2 6.5 3 8 24.031 17.022 81.8 100 AMP 1419 2-BR+D 869 2.607 1378 2068 1.00 0.675 0.675 2.35 2 2 6.5 3 8 24.457 17.193 82.7 100 AMP 1423 2-BR+D 884 2.652 1992 2988 1.00 1.00 0.75 0.75 3.50 2 2 6.5 3 8 25.652 18.361 88.3 100 AMP 1425 1-BR 559 1.677 1256 1883 1.50 0.75 2.25 3 2 1 6.5 3 8 23.427 16.721 80.4 100 AMP 1426 1-BR 671 2.013 1003 1505 1.00 0.75 1.75 1.5 2 6.5 3 8 23.263 16.355 78.6 100 AMP 1427 1-BR 662 1.986 1003 1505 1.00 0.75 1.75 1.5 2 6.5 3 8 23.236 16.344 78.6 100 AMP 1428 ST 324 0.972 618 927 1.00 1 1.00 1.5 2 6.5 3 8 21.472 15.189 73.0 100 AMP 1429 ST 357 1.071 618 927 1.00 1.00 2.5 2 6.5 3 8 21.571 15.228 73.2 100 AMP 1430 ST 324 0.972 618 927 1.00 1.00 2 2 6.5 3 8 21.472 15.189 73.0 100 AMP 1431 ST 357 1.071 618 927 1.00 1.00 2 2 6.5 3 8 21.571 15.228 73.2 100 AMP 1432 1-BR 572 1.716 988 1482 1.00 0.675 1.68 3 2 6.5 3 8 22.891 16.161 77.7 100 AMP 1433 1-BR 617 1 1.851 988 .1482 1.00 0.675 1.68 1.5 2 1 6.5 3 8 23.026 16.215 78.0 100 AMP 1434 1-BR+D 577 1.731 1009 1514 1.00 0.75 1.75 1.5 2 6.5 3 8 22.981 16.242 78.1 100 AMP 1435 ST 357 1.071 618 927 1.00 1.00 1.5 2 6.5 3 8 21.571 15.228 73.2 100 AMP 1436 1-BR 465 1.395 1267 1900 1.50 0.75 2.25 3 2 6.5 3 8 23.145 16.608 79.8 100 AMP 1437 ST 356 1.068 618 927 1.00 1.00 2 2 6.5 3 8 21.568 15.227 73.2 100 AMP 1439 1-BR 578 1.734 1267 1900 1.20 1.00 2.20 0 2 6.5 3 8 23.434 16.694 80.3 MC14 TOTAL 28 15781 47.343 49.4 56 182 84 224 642.718 212.097 589.2 APARTMENT UNIT LOAD CALCULATION - METER CENTER (MC15) APARTMENT PANEL UNITTYPE AREA GENERAL LIGHTING LOAD MINIMUM WATTS REQD MAXIMUM WATTS REQD H1 KW H2 KW I H3 KW I H4 KW HEATING KW TOTAL LOAD DW / GD WASHER/ DRYER SMALL APPLIANCE RANGE CONNECTED LOAD DEMAND LOAD DEMAND AMPS FEEDER SIZE 1501 ST 339 1.017 760 1140 1.20 1.20 2 2 6.5 3 8 21.717 15.407 74.1 100 AMP 1502 1-BR 474 1.422 1246 1869 1.50 0.75 2.25 2 2 6.5 3 8 23.172 16.619 79.9 100 AMP 1503 2-BR 869 2.607 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.457 17.193 82.7 100 AMP 1504 1-BR 541 1.623 988 1482 1.00 0.675 1.68 3 2 6.5 3 8 22.798 16.124 77.5 100 AM P 1506 1-BR 541 1.623 988 1482 1.00 0.675 1.68 1.5 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1507 2-BR+D 869 2.607 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.457 17.193 82.7 100 AMP 1508 ST 306 0.918 618 927 1.00 1.00 1.5 2 6.5 3 8 21.418 15.167 72.9 100 AMP 1510 ST 306 0.918 618 927 1.00 1.00 1.5 2 6.5 3 8 21.418 15.167 72.9 100 AMP 1511 2-BR+D 869 2.607 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.457 17.193 82.7 100 AMP 1612 1-BR 541 1.623 988 1482 1.00 0.675 1.68 3 2 6.5 3 8 22.798 16.124 77.5 100 AMP 1515 2-BR+D 869 2.607 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.457 17.193 82.7 100 AMP 1518 2-BR 727 2.181 1363 2044 1.00 0.675 0.675 2.35 2 2 6.5 3 8 24.031 17.022 81.8 100 AMP 1519 2-BR+D 896 2.688 1378 2068 1.00 0.675 0.675 2.35 2.5 2 6.5 3 8 24.538 17.225 82.8 100 AMP 1523 2-BR+D 884 2.652 1992 2988 1.00 1.00 0.75 0.75 3.50 2 2 6.5 3 8 25.652 18.361 88.3 100 AMP 1525 1-BR 559 1.677 1256 1883 1.50 0.75 2.25 2 2 6.5 3 8 23.427 16.721 80.4 100 AMP 1526 1-BR 672 2.016 1003 1505 1.00 0.75 1.75 3 2 6.5 3 8 23.266 16.356 78.6 100 AMP 1527 1-BR 663 1.989 1003 1505 1.00 0.75 1.75 1.5 2 6.5 3 8 23.239 16.346 78.6 100 AMP 1528 ST 324 0.972 618 927 1.00 1.00 1.5 2 6.5 3 8 21.472 15.189 73.0 100 AMP 1529 ST 357 1.071 618 927 1.00 1.00 1.5 2 6.5 3 8 21.571 15.228 73.2 100 AMP 1530 ST 324 0.972 618 927 1.00 1.00 2.5 2 6.5 3 8 21.472 15.189 73.0 100 AMP 1531 ST 357 1.071 618 927 1.00 1.00 2 2 6.5 3 8 21.571 15.228 73.2 100 AMP 1532 1-BR 572 1.716 988 1482 1.00 0.675 1.68 3 2 6.5 3 8 22.891 16.161 77.7 100 AMP 1533 1-BR 617 1.851 988 1482 1.00 0.675 1.68 1.5 2 6.5 3 8 23.026 16.215 78.0 100 AMP 1534 1-BR+D 577 1.731 1009 1514 1.00 0.75 1.75 1.5 2 6.5 3 8 22.981 16.242 78.1 100 AMP 1535 ST 357 1.071 618 927 1.00 1.00 1.5 2 6.5 3 8 21.571 15.228 73.2 100 AMP 1536 1-BR 465 1.395 1267 1900 1.50 0.75 2.25 2.5 2 6.5 3 8 23.145 16.608 79.8 100 AMP 1537 ST 356 1.068 618 927 1.00 1.00 2 2 6.5 3 8 21.568 15.227 73.2 100 AMP 1539 1-BR 577 1.731 1267 1900 1.20 1.00 2.20 0 2 6.5 3 8 23.431 16.692 80.3 MC15 TOTAL 28 15808 47.424 49.4 56 182 84 224 642.799 212.124 589.2 REVIEWED FOR COMPLIANCE WITh NFPA 70 - NEC RECEIVED CITY OF TUKWILA UEC 0 3 7015 OCT 15 2015 City of Tukwila PERMIT CENTER BUILDING DIVIS'`_,.:. CALL INDEX CALL NAME CALC. NAME MCI MCI MCI MC13 MCI MCI 4- MCI 5 SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE I � Z i I C I � Z I W F- W cn LU � I 0 c+3 w co Uj w� � M co d, 0 rn d LL CD C-4 cm C5 m rn N m N o 4- M CN CCV N REGISTRATION L. b �y "•� 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31, SEATTLE, WA 98103 PHONE: (206) 8264U7 FAX:. (206) 826.4446 SHEET TITLE AND NUMBER APARTMENT LOAD CALC E7.04 3 W w GENERAL NOTES 1. ALL BRANCH CIRCUITS ARE TO BE 1" CONDUIT WITH #10 CU CONDUCTORS UNLESS OTHERWISE NOTED. ROOF STAIRWELL APT. STAIRWELL ELEV LOBBY STAIRWELL ELEV HOTEL LOBBY RISER SD2 ARX11-5 RISER FSD RISER J 1TD 2TC LEVEL 19 STAIRWELL APT. APT. ELEV STAIRWELL STORAGE DATA ELEC ROOM CORRIDOR EXT APT. STAIRWELL CORRIDOR LOBBY ARX18-29 SHAFT CORRIDOR RISER SD1 AR9-19 AR9-15 RISER RISER RISER SD4 - ARX1-7 —FSD--N. RISER RISER RISER RISER RISER 3-I-M 1 Ti 1 TH 1 TB 1 TE RISER RISER ATM 1 TF ARX11-5 FiD RISER RISER 4TC 3TC 6TC AR O A 2� LV4 RISER RISER RISER RISER 1 T8 1 T6 1 T5 1 T3 ARX11-7 F D ARX18 ARX 18 29 1 I ARX1-34 IG IG -2 AR 11 _ LEVEL 18 STAIRWELL FIRE APT. AR9-25 AR9-23 AR9-27 AR9-21 AR9-31 APT. STAIRWELL STORAGE DATA APT. STAIRWELL ALARM CORRIDOR ELEV CORRIDOR (AR9-29 LOBBY AR9-22 AR9-24 AR9-26 AR9-28 ARX1-7 ARX11-5 RISER ARX11-7 FSD FSD AR9 AR $ ARX 18 28 1 T2 FSD LEVEL 17 ARX1-32AAAAAA A6IG IG -4 STAIRWELL FIRE APT. APT. STAIRWELL STORAGE DATA APT. STAIRWELL ALARM CORRIDOR ELEV CORRIDOR LOBBY AR9-30 ARX1-7 ARX11-3 ARX11-7 F1D FSD A89 AR9 27 FSD ARX18 t LEVEL 16 ARX1-30 J6 6 A IG IG -6 A STAIRWELL FIRE APT. APT. STAIRWELL STORAGE DATA APT. STAIRWELL ALARM CORRIDOR ELEV CORRIDOR LOBBY ARX1-7 ARX11-3 ARX11-9 F1D FF-S-D-1 A69 AR9 ARX18 26 F1D LEVEL 15 ARX1-28 JAAA IG IG 8 STAIRWELL FIRE APT. APT. STAIRWELL STORAGE DATA APT. STAIRWELL ALARM CORRIDOR ELEV CORRIDOR LOBBY RISER ARX1-5 ARX11-3 RISER LV3 ARX11-9 F;D FSD A AR9 TC F 69 ARX11 lIG 2 1D LEVEL 14 ARX1-26 J IG -2 J STAIRWELL FIRE APT. APT. STAIRWELL STORAGE DATA APT. STAIRWELL ALARM CORRIDOR ELEV CORRIDOR LOBBY ARX1-5 ARX11-3 ARX11-9 F 1 D RISER 2TM F 1 D A 49 AR9 ARX 1 24 FSD ARX1-24 IG IG -4 J LEVEL 13 STAIRWELL FIRE APT. APT. STAIRWELL STORAGE DATA APT. STAIRWELL ALARM CORRIDOR ELEV CORRIDOR LOBBY ARX1-5 ARX11-1 ARX11-11 FSD F1D A49 �4 F 1D ARX1-22 J ARX11 IG IG -6 J 23 LEVEL 12 STAIRWELL FIRE APT. APT. STAIRWELL ELEV LOBBY DATA ELEC ROOM HOTEL STAIRWELL HK ALARM CORRIDOR ELEV HOTEL CORRIDOR LOBBY ARX1-5 ARX11-1 J J PANEL ARX11 ARX11-11 FSD FSD AR9 AR9 J L FFED-1 HR1 HR1 -2 -12 ARX11 22 -49 -59 ARX1-20 JAA IG IG -8 J ARX11-29 IG IG LEVEL 11 STAIRWELL FIRE APT. APT. STAIRWELL ELEV LOBBY DATA HOTEL STAIRWELL HK ALARM CORRIDOR ELEV HOTEL CORRIDOR LOBBY RISER ARX1-3 ARX11-1 EF ARX11-11 �FSD ' FSD AR9' AR9 L, EF FSD HR1 HR1 i ARX1-18 J AAAAAAIG 1 —2 —12 ARX11 IG IG -10 J 14 1 —49 -59 IG EL 10 STAIRWELL FIRE APT. APT. ARX11-1 ELEV LOBBY DATA ELEC ROOM HR1-60 HOTEL CORRIDOR STAIRWELL HK ALARM CORRIDOR ELEV FSD HOTEL LOBBY ARX1-3 ARX11-11 PANE FSD ek AR9 � F 1 D HR147 H 57 AR9 AR9 ? A-7A ARX11 ? IAIG ARX1-16 J STAIRWELL IG-1 IG -12 J a a (Tb db db IG LEVEL 9 STAIRWELL FIRE APT. APT. STAIRWELL ELEV LOBBY DATA HOTEL STAIRWELL HK ALARM CORRIDOR ELEV HOTEL CORRIDOR LOBBY ARX1-3 ARX7-3 ARX7-7 FSD F D AR9 AR9 F S D H H 1 ARX7 19 1F 47 57 ARX1-14 J IG IG -2 J IG IG EL STAIRWELL FIRE APT. APT. STAIRWELL ELEV LOBBY DATA ELEC ROOM HOTEL STAIRWELL HK ALARM CORRIDOR ELEV HOTEL CORRIDOR LOBBY ARX1-3 ARX7-3 J J � -L ARX7-7 FSD RISER 1TM FSD 1 AR9 AR ARX7 ARX7-29 18 � FSD 1 HR1 HR1 -45 -55 1 -5 -13 J ARX1-126A IG IG J IG IG LEVEL 7 STAIRWELL FIRE APT. APT. STAIRWELL ELEV LOBBY DATA HOTEL STAIRWELL HK ALARM CORRIDOR ELEV HOTEL CORRIDOR LOBBY ARX1-1 ARX7-3 ARX7-7 FSD FSD AR9 AR9 417 E FSD H H ARX7 2 1 45 55 LEVEL 6 J ARX1-10A A IG IG -6 J RISER IG IG STAIRWELL FIRE APT. APT. STAIRWELL ELEV LOBBY DATA RISER ELEC ROOM LV2 HOTEL STAIRWELL HK ALARM CORRIDOR ELEV HOTEL FTC ARX5-29 CORRIDOR LOBBY ARX1-1 ARX7-3 PANEL ARX7-5 F1D F1D A3 AR9 1 ARX5 16 A f F1D "43 "-53 6ARX1-8 IG IG -2 J IG IG LEVEL 5 STAIRWELL FIRE APT. APT. STAIRWELL ELEV LOBBY DATA HOTEL STAIRWELL HK ALARM CORRIDOR ELEV HOTEL CORRIDOR LOBBY ARX1-1 ARX7-1 ARX7-5 F 1 D I f FSD A3 AR9 ARX5 15 V 1 D FSD H 43 H 53 J ARX1-6 AIG IG -4 J 44 IG IG LEVEL 4 STAIRWELL FIRE APT. APT. STAIRWELL ELEV LOBBY DATA HOTEL STAIRWELL HK ALARM CORRIDOR ELEV HOTEL CORRIDOR WP LOBBY ARX1-1 ARX7-1 ARX7-5 FSD FSD AR9 AR9 ARX5 L 14 WP FSD 1 HR1 HR1 -41 -51 J ARX1-4 -1 -9 IG IG -6 J RISER RISER IG IG LEVE STAIRWELL FIRE APT. APT. ELEV STAIRWELL ELEV LOBBY DATA ELEC ROOM LV1 SD5 HK ALARM CORRIDOR LOBBY HOTEL PANEL HR2A-3 HR2A-38 HR2A-40 HR2A-42 HR2A-44EVlE !-U AR9-36 AR9-34 AR9-32 R9-33 AR9-32 AR9-38 HR2A-46 HR2A OMPLIANCE WITF ARX1-1 ARX7-1 RISER RISER RISER RISER RISER NFPA 70 -NEC o FSD FSD 1 AR9 AR9 ARX5 AT8 AT6 AT5 AT3 AT2 HR1 HR1 -41 -51 0 �_' Lb -1 -g 6IG LEVf�L `z 0 3 ZQ15 J ARX1-2 RISER IG - 8 J IG IG 0 ELEC ROOM STAIRWELL RISER RISER RISER RISER RISER � RISER STAIRWELL SD3 RISER RISER RISER RISER ELEC ROOM ATJ ATH ATE ATM ATF ELEV ATD BTC CTC DTC ETC PANEL Cfty ofTu Wtls. LOBBY HR1 UlLDlNG DlVISI�::���� PANEL RISER RISER ARXII HK1 HK2 Ln RECEIVED LEVELGITY OF TUKWILA w OCT 15 2015 0 BRANCH CIRCUIT RISER DIAGRAM ui W 1L0 PERMIT CENTER o SCALE: NONE 0 ISSUE 0 Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT n000 W 3: O w Y z O >Y Q WJ pY �..J Q H z cM N •� (N r� v) CONSULTANT REGISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826.4446 SHEET TITLE AND NUMBER BRANCH CIRCUIT RISER DIAGRAM * KIR x G GENERAL NOTES 1. ALL BRANCH CIRCUITS ARE TO BE 1" CONDUIT WITH #10 CU CONDUCTORS UNLESS OTHERWISE NOTED. ROOF APT, ELEV STAIRWELL ELEVATOR ELEVATOR ELEVATOR RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER LOBBY 04 05 06 18A 18B 18C 18D 18E 18F 18G 18H 181 18J 18K 18L 18M 18N 18P P PLAN NOTES 19L 1O SEE LIGHTING PLANS FOR ADD111ONAL LIGHT FIXTURES. RISER RISER TMW TCW O2 SEE LIGHTING PLANS FOR ADDITIONAL CONTROL DETAILS. RISER E 19-45 AX19-45 AX19-45 AX19-45 AX19-45 AX19-45 AX19-45 TDX EAX1771 AX19-43 AX19-43 AX19-43 AX19-43 AX19-43 AX19-43 AX19-43 I AX19-43 J RISER RISER AX11-7 TMX E TCY AP9-2 J STAIRWELL E E LEVEL 19 J AX51 RISER RISER TRASH APT, ELEV AX11-5 E E 2 TEX CHUTE LOBBY E TGY J J J t t t t E0 t E E E JE E E E E E E E E E E E E E E E J E APT. AP9-2 AX11-7 E LEVEL 18 STAIRWELL CORRIDOR STAIRWELL I APT. RISER RISER CORRIDOR J APT. RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER TRASH CHUTE APT, ELEV LOBBY TMZ TMY E CORRIDOR TJZ TIZ TIY THZ TGZ TFZ TFY TEZ TDZ TDY TLX 2 E 41 J J E E Eek V-y t\01 t$fE t E E E E E (AX11 E E E E E E E E E E E (AX11 (AX11 (AX11 J AX11 E AX11 AX11 AX11 AX11 AX11 AX11 AX11 AX11 E LEVEL 17 -5 -7 STAIRWELL -5 -7 -5 -7 -5 -7 -5 -7 -5 -7 -5 STAIRWELL APT. APT. TRASH APT, ELEV CORRIDOR E J CORRIDOR 2 CHUTE LOBBY E J J J E E Xy E E E E E E E E E E E E E E E E J E E RISER RISER RISER LEVEL 16 STAIRWELL STAIRWELL 01 02 03 APT. APT. TRASH APT, ELEV CORRIDOR E J CORRIDOR 2 CHUTE LOBBY E t -t J J J T t E E E E E E E E E E E E E E E E E E J E E E E E E STAIRWELL E E STAIRWELL LEVEL 15 APT. APT. TRASH APT, ELEV CORRIDOR E J CORRIDOR 2 CHUTE LOBBY E AX11] AX111 9AX11 -9 -11 3 -13 J J'L t t \cy E tJ E E E E E E E E E E E E E E E E E J ... STAIRWELL E E STAIRWELL LEVEL 14 APT. APT. TRASH APT, ELEV CORRIDOR E J CORRIDOR 2 CHUTE LOBBY E NZY J J tJ Xy E xy E E E E E E E E E E E E E E E E E J STAIRWELL E E STAIRWELL LEVEL 13 APT. APT. TRASH APT, ELEV CORRIDOR E J CORRIDOR 2 CHUTE LOBBY E JIL E E E E E E E E E E E E E E E E E E J STAIRWELL E STAIRWELL LEVEL 12 APT. APT. TRASH APT, ELEV CORRIDOR E® J CORRIDOR CHUTE LOBBY E J J J J J J J PANEL AX11 J J J J J J J J J J J J J J 2 E E E_ E J J J J E E E STAIRWELL E E E E E E E E E E E E E STAIRWELL LEVEL 11 APT. APT. TRASH APT, ELEV CORRIDOR E J CORRIDOR 2 CHUTE LOBBY E E E T E E E E E E E E E E E E E E E J E E E E E E STAIRWELL E E STAIRWELL LEVEL 10 APT. CORRIDOR E J APT. CORRIDOVOY E1<y E r E 17 E E E E E E E E E E E E E PANEL AP9 TRASH APT, ELEV J E STAIRWELL E CHUTE LOBBY STAIRWELL LEVEL 9 APT. J APT. TRASH CORRIDOR E CORRIDOR 2 CHUTE E J JI IJ E E E E E E E E E E E E E E E E E E APT, ELEV - • J STAIRWELL E LOBBY E STAIRWELL LEVEL 8 APT. APT. TRASH APT, ELEV CORRIDOR E J CORRIDOR 2 CHUTE LOBBY E J J J E E E E E E E E E E E E E E E E E E J STAIRWELL E E STAIRWELL LEVEL 7 APT. APT. TRASH APT, ELEV CORRIDOR E J CORRIDOR CHUTE LOBBY E PANEL J J J J J J J AX7 J J J J J J J J J J J J J 2 E E STAIRWELL E E E E E E E E E E E E E E E J J J E J E® STAIRWELL LEVEL 6 APT. APT. TRASH APT, ELEV CORRIDOR E J CORRIDOR 2 CHUTE LOBBY E J J J E E E E E E E E E E E E E E E E E E J E E E E E E STAIRWELL E E STAIRWELL LEVEL 5 APT. APT. TRASH APT, ELEV CORRIDOR E J CORRIDOR 2 CHUTE LOBBY E &IL= J J J E Ev t E E E E E E E E E E E E E E E E J STAIRWELL E E STAIRWELL LEVEL 4 APT. APT. TRASH APT, ELEV CORRIDOR E J CORRIDOR 2 CHUTE LOBBYJIL E EKy E E E J E J J E E E E E E E E E E E E E E E O J E STAIRWELL STAIRWELL LEVEL 3 APT. AX7 AX7 APT. AX7 AX7 AX7 AX7 AX7 AX7 AX7 AX7 AX7 AX7 AP9-6 AX7-4 CORRIDOR -2 -4 E J (AX7 CORRIDOR -2 -4 -2 -4 -2 -4 -2 -4 -2 -4 -2 2 E AX7-2 J J J AX7-9 cli E E E E E E E E E E E E E E E E E RISER RISER E AX11 AX11 AX11 0 REVIEWED.FO RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER TEB TEC TRASH APT, ELEV COMPLIANCE WITH J TMA TMB STAIRWELL E O TJA TIA TIB THA TGA TFA TFB TEA TDA TDB TCA CHUTE LOBBY E STAIRWELL LEVEL 2 NFPA 70 -NEC N � AX7-2 E Em-J AP9-4 E 0 DEC 0 3 2015 RISER AX7-4 RISER 3 TMC J TCC RISER E Ld City Of TLJR�i'ffa TCB BUILDING DIVI!I E RISER RISER E E E E E E STAIRWELL TMD TDD E STAIRWELL RISER 11LEVEL RISER RISER 1 RECEIVED CITY OF TUKWILA uj APARTMENT LIGHTING RISER DIAGRAM OCT 5 20�5 Q SCALE: NONE PERMIT CENTER w r7 0 0 ISSUE Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT CONSULTANT 2EGISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826.4446 SHEET TITLE AND NUMBER APARTMENT LIGHTING RISER DIAGRAM 1 i m 3 v X W GENERAL NOTES 1. ALL BRANCH CIRCUITS ARE TO BE 1" CONDUIT WITH #10 CU CONDUCTORS UNLESS OTHERWISE NOTED. ROOF ELEVATOR ELEVATOR ELEVATOR RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER STAIRWELL 01 02 03 18Z 18Y 18X 18W 18V 18U 18T 18S 18R 18Q 180 18N 18M PANEL PLAN NOTES AX19 O SEE LIGHTING PLANS FOR ADDITIONAL LIGHT FIXTURES. RISER T2W E J 1 �AX`l —9 RISER T2V APT. 1. 1 CORRIDOR STAIRWELL E LEVEL 19 DATA ROOM rAX 19 19 11 -43 —45 —43 —45 —(AX43rAX19 —45Ax —43 ((AX —45 —43 —45 —43 45 —43 E " J E f t E E E E E E E E E E E E E E APT. CORRIDOR STAIRWELL E LEVEL 18 DATA ROOM RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER T9X T71 T72 T73 T61 T62 T51 T41 T42 T31 T32 -K & T21 E J E t t t t t E t t t AP9 E AX11 E AX11 E AX11 E AX11 E AX11 E AX11 E AX11 E AX11 E AX11 E AX11 E AX11 —8 —1 —3 —1 —3 —1 —3 —1 —3 —1 —3 —1 APT. E LEVEL 17 CORRIDOR STAIRWELL 7 DATA ROOM J E J E E T t y E E E E E E E E E E E E RISER RISER RISER APT. E � LEVEL 16 04 05 06 CORRIDOR STAIRWELL DATA ROOM J E J E -t E - E -t E E EHi E E E E E E E E E E E E E E . APT. CORRIDOR STAIRWELL E LEVEL 15 DATA ROOM J E AX11 AX11 AX11 - - J —15 —17 —19 E E E E E E E E E E E E E APT. CORRIDOR STAIRWELL E LEVEL 14 DATA ROOM J E E V<Y E tJ E E E E E E E E E E E E APT. E CORRIDOR STAIRWELL LEVEL 13 DATA ROOM J E J E E eK E E E E E E E E E E E E APT. O CORRIDOR STAIRWELL E LEVEL 12 HOTEL ELEV LOBBY J E PANEL J J J J EEAX11 E HP2-7 J J J J J J J J J J J y HOTEL O E E E E E y E y E CORRIDOR STAIRWELL E LEVEL 11 HOTEL ELEV LOBBY J I I I E --�3- J J J EJ J J E EJ EJ EJ EJ EJ EJ E E E E E E E HOTEL E O CORRIDOR STAIRWELL LEVEL 10 HOTEL ELEV LOBBY J E PANEL ek J J J J J J J J J J J �'9 E t E E E E E E t E t t Q E HOTEL E CORRIDOR STAIRWELL LEVEL 9 HOTEL ELEV LOBBY J E J J J J J J J J J J J J J E E E E E E E E T T O E HOTEL E CORRIDOR STAIRWELL LEVEL 8 HOTEL ELEV LOBBY =ma J E PANEL AX7 J J J J J J J J J J J J J J J E E E E E E E E QQ E HOTEL E CORRIDOR STAIRWELL LEVEL 7 HOTEL ELEV LOBBY J E J J J J J J J J J J J J J J J yfK E E E E E E E E E HOTEL E O CORRIDOR STAIRWELL LEVEL 6 HOTEL ELEV LOBBY J Ey J ni J J J J J J J J J J J J J J E E E E E E E E E E E E E E O E HOTEL E CORRIDOR STAIRWELL LEVEL 5 HOTEL ELEV LOBBY J E J J J J J J J J J J J J J J J E E E E E E E E O E HOTEL E CORRIDOR STAIRWELL LEVEL 4 HOTEL ELEV LOBBY J E w J E J HP2-5 EJ HX1-4 EJ HX1-2 J HP2-7 EJ J HX1-4 HP2-5 EJ HX1-2 J HP2-3 EJ HX1-4 J HP2-1 EJ HX1-2 J HP2-3 EJ J HX1-4 HP2-1 E HX1-2 OHOTEL 1 E lQwv CORRIDOR STAIRWELL LEVEL 3 PANEL HOTEL ELEV LOBBY J E HP2 J E J J PANEL REVIEWED FOR N RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER RISER HOTEL HX1-6 HX1 COMPLIANCE WITH T9A T8A T7F T6A T6B T5A T5B T4A T4B T3A T3B T3C T2A T2B T2C CORRIDOR STAIRWELL E LEVEL 2 NFPA 70 - NEC HOTEL ELEV LOBBY HX1 J `� " (HP2-7 —2 —15 -17 —19 E— DEC 0 3 2015 RISER HX1-8 J T2F RISER RISER City Of-Tul( ile T7D T7A E E BUILDING DIVISIC)"I E E E E E E RISER Of RISER RISER RISER STAIRWELL T2E LEVEL 1 Z 14 15 16 RECEIVED CITE' OF TUKWILA W HOTEL LIGHTING RISER DIAGRAM uj OCT 1 2015 1 SCALE: NONE o PERMIT CENTER W ; . o 0 ISSUE n I Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB =YPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry w 3: O w Y z a� wQ W J pY (D zQ H z M N r� v) CONSULTANT REGISTRATION 5 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826- 447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER HOTEL LIGHTING RISER D IAG RAM E7.07 0 W U) -, -jLq o N O r � W 3 O r)\ O M O \ � O ISSUE � Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA N0, PROJECT L.L W 3: O W Y !Y z a� O W Q W J pY �.J Q H z N N N VJ >ULTANT NAP eav Z C w W W Z c-� — U w ~ Z � W w 0 H Lu � � U) �M W 0 Z �QaLL _ o 0 U) M c M W 0 IY C14 cl) I-Q m m F— NXN(VIN ISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826.4447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER LOW VOLTAGE RISER DIAGRAM E7.08 PANEL TR LOCATION: FUTURE TENANT SERVING: FUTURE TENANT FED FROM: TP (VAA30KVAXFMR T-TR) 208/120 VOLT 100 AMP BUS RATING SCCR: 10,000 A 3 PHASE 100 AMP MAIN BREAKER AFC: 1,894 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 SPARE S - 20/1 A 20/1 1.080 R RCPT - RM 107 2 3 SPARE S - 20/1 B 20/1 - S SPARE 4 5 SPARE S - 2011 C 20/1 - S SPARE 6 7 SPARE S - 20/1 A 20/1 - S SPARE 8 9 SPARE S - 20/1 B 20/1 - S SPARE 10 11 SPARE S - 20/1 C 20/1 - S SPARE 12 13 SPARE S - 20/1 A 20/1 - S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 ISPARE S - 20/1 1 B 20/1 1 - S SPARE 22 23 SPARE S - 20/1 C 2011 - S SPARE 24 25 SPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 2011 B 20/1 - S SPARE 28 29 SPARE S - 2011 C 20/1 - S SPARE 30 31 SPARE S - 2011 A 20/1 - S SPARE 32 33 SPARE S - 20/1 B 20/1 - S SPARE 34 35 SPARE S - 20/1 C 20/1 - S SPARE 36 37 SPARE S - 20/1 A 20/1 - S SPARE 38 39 SPARE S - 20/1 B 20/1 - S SPARE 40 41 SPARE S - 20/1 C 20/1 - S SPARE 42 PHASE LOAD PHASE A= 1.08 KVA PHASE B= KVA PHASE C= KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL TR 1.08 1.08 KVA 3.00 AMP PANEL TR KVA AMP CONN. LOAD 1.08 1.08 KVA 3.00 AMP CALC. LOAD 1.08 1.08 KVA 3.00 AMP NOTES: FUTURE TENANT PANELBOARD. J W N Z N Q O n O PANEL BG LOCATION: FIRE PUMP ROOM SERVING: FIRE PUMP EMERGENCY LOADS FEDFROM: 750KWGENERATOR 480/277 VOLT 3 PHASE 4 WIRE 600 AMP MAIN LUGS ONLY SCCR: 18,000 A AFC: 8,181 A MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 FIRE PUMP (75 HP) (MA400AATS-2) (NEC 700 EMERGENCY) M - - 79.800 - - 200/3 - - A 400/3 - - 149.580 - - M - - FIRE PUMP (150 HP) (VIA400AATS-3) (NEC 700 EMERGENCY) 2 3 B 4 5 C 6 PHASE LOAD PHASE A= 76.46 KVA PHASE B= 76.46 KVA PHASE C= 76.46 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 229.38 149.58 229.38 KVA 275.90 AMP CALC. LOAD 229.38 37.40 266.78 KVA 320.88 AMP REQUIRED SERVICE -ENTRANCE RATED OPTIONS: NEMA-3R ENCLOSURE NOTES: 1.) 600A BUSSED GUTTER. PANEL BD-2 LOCATION: VERTICAL BUS DUCT (APARTMENTS) SERVING: APARTMENT LOADS FED FROM: MSB 480/277 VOLT 2500 AMP MAIN LUGS ONLY SCCR: 65,000 A 3 PHASE AFC: 49,338 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 METER CENTER (MC3) (VAA300KVAXFMRT3) - D - - 223.568 - - 400/3 - - A 400/3 - - 247.698 - - D - - METER CENTER (MC4) (VIA 300KVA XFMR T4) - 2 3 B 4 5 C 6 7 METER CENTER (MC6) (VIA 300KVA XFMR T6) - D - - 247.975 - - 400/3 - - A 400/3 - - 247.974 - - D - - METER CENTER (MC8) (VIA 300KVA XFMR T8) - 8 9 B 10 11 C 12 13 METER CENTER (MC10) (VIA 300KVA XFMR T10) - D - - 247.809 - - 400/3 - - A 400/3 - - 230.056 - - D - - METER CENTER (MC12) (VIA 300KVA XFMR T12) - 14 15 B 16 17 C 18 19 METER CENTER (MCI 3) (VAA300KVAXFMR T13) - D - - 212.077 - - 400/3 - - A 400/3 - - 212.097 - - D - - METER CENTER (MC14) (MA300KVAXFMR T14) - 20 21 g 22 23 C 24 25 METER CENTER (MC 15) (VAA300KVAXFMR T15) D - - 212.124 - - 400/3 - - A 400/3 - - 212.098 - - D - - METER CENTER (MC16) (VIA300KVAXFMR T16) - 26 27 B 28 291- C 30 31 METER CENTER (MC17) (VAA300KVAXFMR T17) - D - - 214.780 - - 400/3 - - A 400/3 - - 179.107 - - D - - METER CENTER (MC18) (VIA 300 KVA XFMR T18) - 32 33 g 34 35 C 36 37 SPACE - - S - - - - - /3 - - A /3 - - - - - S - - SPACE - - 38 39 B 40 [42 41 C PHASE LOAD PHASE A= 895.79 KVA PHASE B= 895.79 KVA PHASE C= 895.79 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 1,973.30 1,973.30 KVA 2,373.51 AMP CALC. LOAD 1,973.30 1,973.30 KVA 2,373.51 AMP NOTES: 1.) REFER TO APARTMENT LOAD CALCS, SHEETS E7.03 AND E7.04, FOR METER CENTER LOAD CALCULATIONS. 2.) PANEL SCHEDULE IS SHOWN FOR VERTICAL BUS DUCT. OVERCURRENT DEVICES SHWWN ARE FUSE SIZES REQUIRED AT FUSIBLE DISCONNECTS CONNECTED TO BUS DUCT. REFER TO ONE -LINE DIAGRAM. PANEL T P LOCATION: FUTURE TENANT SERVING: FUTURE TENANT FED FROM: MSB 480/277 VOLT 400 AMP MAIN LUGS ONLY SCCR: 50,000 A 3 PHASE AFC: 44,959 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 FUTURE POWER - - D - - 150.000 - - 200/3 - - A 20/1 0.793 L LTG - RM 107 (FUT. HOTEL/SPA) 2 3 B 20/1 - S SPARE 4 5 C 20/1 - S SPARE 6 7 SPARE S - 20/1 A 20/1 - S SPARE 8 9 SPARE S - 20/1 B 20/1 - S SPARE 10 11 SPARE S - 20/1 C 20/1 - S SPARE 12 13 SPARE S - 20/1 A 20/1 S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 20/1 B 20/1 - S SPARE 28 29 SPARE S - 20/1 C 201 - S SPARE 30 31 SPARE S - 20/1 A 20/1 - S SPARE 32 33 SPARE S - 20/1 B 20/1 - S SPARE 34 35 SPARE S - 20/1 C 20/1 - S SPARE 36 37 SPARE S - 20/1 A 60/3 - - 1.080 - - P - - PANEL TR (FUTURE TENANT) (VIA30KVAXFMR T-TR) - 38 39 SPARE S - 20/1 B 40 41 SPARE S - 20/1 C 42 PHASE LOAD PHASE A= 51.87 KVA PHASE B= 50.00 KVA PHASE C= 50.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL TP 0.79 150.00 150.79 KVA 181.38 AMP PANEL TR 1.08 1.08 KVA 1.30 AMP CONN. LOAD 0.79 1.08 150.00 151.87 KVA 182.67 AMP CALC. LOAD 0.99 1.08 150.00 152.07 KVA 182.91 AMP NOTES: FUTURE TENANT PANELBOARD. PANEL PSE T LOCATION: 2500KVA(SITE EXTERIOR) SERVING: BUILDING LOADS & FIRE PUMPS FED FROM: PSE 480/277 VOLT 3 PHASE AFC: 56,500 A 4 WIRE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT I MSB-1 (MAIN SWITCHBOARD) - - P - - 2125.173 - - /3 - - A /3 - - 2474.709 - - P - - MSB-2 (MAIN SWITCHBOARD) - - 2 3 B 4 5 C 6 7 FIRE PUMP (75 HP) -PRIMARY (VIA200AATS/FP CONTROLLER) - M - - 79.800 - - /3 - - A /3 - - 149.580 - - M - - FIRE PUMP (150HP) - SECONDARY (VIA400AATS/FP CONTROLLER) - 8 9 B 10 11 C 12 PHASE LOAD PHASE A= 1,637.62 KVA PHASE B= 1,607.49 KVA PHASE C= 1,584.15 KVA LOADTYPE L R M H WH HM D A K LM TOTAL LOADS PANEL PSE T 229.38 149.58 229.38 KVA 275.90 AMP PANEL MSB-1 0.79 1.08 2123.30 2,125.17 KVA 2,556.19 AMP PANEL MSB-2 114.25 1 123.80 1 1787.35 1 41.04 1 30.96 1 132.35 1 144.36 1 41.60 59.01 81.47 2,474.71 KVA 2,976.61 AMP CONN. LOAD 115.04 1 124.88 2,016.73 41.04 30.96 132.35 2,267.66 41.60 59.01 1 149.58 4,829.26 KVA 5,808.70 AMP CALC. LOAD 143.80 67.44 2,016.73 41.04 30.96 51.70 2,267.66 41.60 1 38.36 1 37.40 4,736.68 KVA 1 5,697.34 AMP REQUIRED SERVICE -ENTRANCE RATED OPTIONS: NOTES: PANEL M B-1 LOCATION: ELEC RM 1 ST FLR SERVING: BUILDING (SERVICE) LOADS FEDFROM: UTILITYXFMR 480/277 VOLT 3 PHASE 4 WIRE 3000 AMP MAIN LUGS ONLY SCCR: 65,000 A AFC: 56,829 A MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 APARTMENT BUS DUCT (BD-2) - - P - - 1973.300 - - 2500/3 - - A 400/3 - - 151.873 - - P - - PANELTP (NOTE 1) - - 2 3 B 4 5 C 6 PHASE LOAD PHASE A= 709.64 KVA PHASE B= 707.77 KVA PHASE C= 707.77 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL MSB-1 KVA AMP BUS DUCT BD-2 1973.30 1,973.30 KVA 2,373.51 AMP PANELTP 0.79 1.08 150.00 151.87 KVA 182.67 AMP CONN. LOAD 0.79 1.08 2,123.30 2,125.17 KVA 2,556.19 AMP CALC. LOAD 0.99 1.08 2,123.30 2,125.37 KVA 1 2,556.42 AMP REQUIRED SERVICE -ENTRANCE RATED OPTIONS: NOTES: 1.) CUSTOMER METERING TO COMPLY VVITH WA STATE ENERGY CODE. PANEL MSB-2 LOCATION: SERVING: FEDFROM: ELEC RM 1 ST FLR BUILDING (SERVICE) LOADS UTILITYXFMR 480/277 VOLT 3 PHASE 4 WIRE 3000 AMP MAIN LUGS ONLY SCCR: 65,000 A AFC: 56,985 A MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 PANEL ADB - - P - - 1106.860 - - 1600/3 - - A 1600/3 - - 1367.849 - - P - - PANEL HDB - - 2 3 B 4 5 C 6 PHASE LOAD PHASE A= 851.52 KVA PHASE B= 823.27 KVA PHASE C= 799.92 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL MSB-2 KVA AMP PANELADB 76.07 67.26 811.47 33.85 15.80 86.40 16.00 43.23 1,106.86 KVA 1,331.35 AMP PANEL HDB 38.18 56.54 975.88 1 7.19 15.15 132.35 57.96 25.60 1 59.01 81.47 1,367.85 KVA 1,645.27 AMP CONN. LOAD 114.25 123.80 1,787.35 41.04 30.96 132.35 144.36 41.60 59.01 81.47 2,474.71 KVA 2,976.61 AMP CALC. LOAD 142.81 66.90 1,787.35 41.04 30.96 51.70 144.36 41.60 38.36 20.37 2,365.44 KVA 2,845.19 AMP REQUIRED OPTIONS: SERVICE -ENTRANCE RATED NOTES: 1.) SERVICE FEEDER SHALL BE CUSTOMER METERED TO COMPLY WITH WA STATE ENERGY CODE. PANEL GEN LOCATION: 750KWGENERATOR (EXTERIOR) SERVING: BUILDING EMERGENCY LOADS FED FROM: 480/277 VOLT 3 PHASE AFC: 8,248A 4 WIRE MOUNTING: FLOOR CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 PANEL BG-2 - - P - - 710.278 - - 900/3 - - A 600/3 - - 229.380 - - P - - PANEL BG-1 (NOTE 1) - - 2 3 B 4 5 C 6 PHASE LOAD PHASE A= 317.72 KVA PHASE B= 312.36 KVA PHASE C= 309.59 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL GEN KVA AMP PANEL GSB-1 64.20 19.98 560.79 1.00 1.15 63.16 43.23 710.28 KVA 854.33 AMP PANEL GSB-2 1 229.38 1 1 1 1 149.58 229.38 KVA 275.90 AMP CONN. LOAD 64.20 19.98 790.17 1.00 1.15 63.16 149.58 939.66 KVA 1,130.23 AMP CALC. LOAD 80.24 14.99 790.17 1.00 1.15 63.16 37.40 988.11 KVA 1,188.51 AMP NOTES: GENERATOR LOAD CALCULATION. 1.) MAGNETIC CIRCUIT BREAKER ONLY, NO THERMAL OVERLOAD. PANEL GSB-1 LOCATION: SERVING: FEDFROM: EMERGENCY SWITCH ROOM BUILDING EMERGENCYLOADS 750KWGENERATOR 480/277 VOLT 3 PHASE 4 WIRE 1200 AMP MAIN LUGS ONLY SCCR: 18,000 A AFC: 8,125 A MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 PANEL AXI (VIA800AATS-1) (NEC 700 EMERGENCY) - P - - 640,904 - - 800/3 - - A 200/3 - - 83.345 - - P - - PANELHLI (VIA200AATS-4) (NOTE 1) (NEC 702 OPTIONAL STANDBY) - 2 3 B 4 5 C 6 PHASE LOAD PHASE A= 240.56 KVA PHASE B= 251.62 KVA PHASE C= 232.08 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL GSB-1 KVA AMP PANEL AX1 66.15 1.08 548.48 1.00 24.20 43.23 640.90 KVA 770.89 AMP PANEL HL1 1 16.22 1 16.20 1 12.31 1 1 1.15 1 37.46 1 1 9.15 83.35 KVA 100.25 AMP CONN. LOAD 82.37 17.28 560.79 1.00 1.15 61.66 43.23 724.25 KVA 871.14 AMP CALC. LOAD 102.96 13.64 560.79 1.00 1.15 61.66 10.81 752.01 KV : P REQUIRED OPTIONS: SERVICE -ENTRANCE RATED NEMA-311 ENCLOSURE CQI! iPLIANCE NFPA 70 - NE NOTES: 1.) SHUNT -TRIP OVERCURRENT DEVICE SHALL BE CONTROLLED VIA GENERATOR CONTROL PANEL FOR LOAD SHEDDING. 015 RECEIVED CITY OF TU KW I I_.A OCT 15 2015 PERMIT CENTER h ITH N 0 0 ,E to i s ( N (t O City Of-TukWilF BUILDING DIMS-1= = PANEL SCHEDULE INDEX PANEL NAME PANEL NAME PANEL NAME TR BG PSE T - BD-2 MSB-1 - - MSB-2 - TP GEN - - GSB-1 ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB =YPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT 0. W 3: 0 w `1 Z a� w Q W J `l < h M N CV V ,J CONSULTANT REGISTRATION 5 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826.4446 SHEET TITLE AND NUMBER ELECTRICAL PANEL SCHEDULES E8.01 PANEL AP19 LOCATION: ELEC RM 19TH FLR SERVING: APARTMENT LOADS FED FROM: ADB 480/277 VOLT 400 AMP MAIN LUGS ONLY SCCR: 14,000 A 3 PHASE AFC: 11,483A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 RTU-1 - - M - - 7.067 - - 15/3 - - A 20/3 - - 11.468 - - M - - WSHP-19-3 - - 2 3 B 4 5 C 6 7 RTU-2 - - M - - 7.067 - - 15/3 - - A 20/3 - - 11.468 - - M - - WSHP-19-1 - - 8 9 B 10 11 C 12 13 ERV-2 - - M - - 26.604 - - 40/3 - - A 15/3 - - 5.817 - - M - - WSHP-19-2 - - 14 15 B 16 17 C 18 19 UH-4 H 3.185 2011 A 20/1 3.186 H UH-6 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 15/3 - - 7.396 - - M - - WSHP-19-5 - - 24 25 SPARE S - 20/1 A 26 27 LTG -APARTMENT CLUB L 0.917 20/1 B 28 29 LTG - LOUNGE, EXERCISE RM, RRS L 1.810 20/1 C 20/3 - - 11.467 - - M - - WSHP-19-6 - - 30 31 LTG - MECHANICAL RM 1900 L 0.244 20/1 A 32 33 SPARE S - 20/1 B 34 35 HVAC UNIT#1 M - - 26.259 - - 40/3 - - C 1513 - - 9.473 - - M - - WSHP-19-7 - - 36 7:]- A 38 39- B 40 41 HVAC UNIT#2 - - M - - 26,259 - - 40/3 - - C 20/3 - - 11.468 - - M - - WSHP-19-8 - - 42 43 A 44 45 B 46 47 SPARE S - 20/1 C 15/3 - - 4.739 - - M - - WSHP-19-9 - - 48 49 RCP-4 (RECIRC PUMP) (LEVEL 19) - - M - - 2.494 - - 15/3 - - A 50 51 B 52 53 C 20/1 - S SPARE 54 55 DWH-11-1 (WFR HTR) (LEVEL 18) - - WH - - 4.500 - - 15/3 - - A 150/3 - - 55.676 - - P - - PNL AR19 (MA75KVAXFMR T-AR19) - - 56 57 B 58 59 C 60 PHASE LOAD PHASE A= 82.33 KVA PHASE B= 79.39 KVA PHASE C= 76.85 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL API 2.97 169.05 6.37 4.50 26.60 182.89 KVA 219.98 AMP PANEL AR19 23.24 4.13 2.30 10.00 16.00 1.92 55.68 KVA 66.97 AMP CONN. LOAD 1 2.97 23.24 173.18 6.37 6.80 1 10.00 16.00 1 1 26.60 1 238.56 KVA 286.95 AMP CALC. LOAD 3.71 16.62 173.18 6.37 6.80 10.00 1 16.00 6.65 239.34 KVA 287.88 AMP REQUIRED FEED-THRU LUGS OPTIONS: NOTES: PANEL AR19 LOCATION: ELEC RM 19TH FLR SERVING: APARTMENT LOADS FED FROM: AP19 (VIA75KVAXFMR T-AR19) 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 225 AMP MAIN BREAKER AFC: 5,160 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 EF-V4 M 0.528 15/1 A 15/1 0.528 M EF-V6 2 3 LOUVER (L-7)19TH FLR MECH RM M 0.100 15/1 B 15/1 0.528 M EF-VI0 4 5 RCPT-MICROWAVE R 1.200 20/1 C 15/1 0.528 M EF-V15 6 7 RCPT-FRIDGE R 1.500 2011 A 15/1 0.360 R RCPT- RM 1902 8 9 RCPT- COFFEE MACHINE R 1.800 20/1 B 15/1 0.360 R RCPT- RM 1902 10 11 RCPT- VENDING MACHINE R 1.000 20/1 C 15/1 0.360 R RCPT- RM 1902 12 13 RCPT R 0.720 20/1 A 20/1 0.360 R RCPT- RM 1902 14 15 RCPT- RM 1905 DISHWASHER R 1.500 20/1 B 20/1 0.360 R RCPT- RM 1902 16 17 RCPT- RM 1905 R 0.540 20/1 C 20/1 0.360 R RCPT- RM 1902 18 19 RCPT- RM 1905 R 0.540 20/1 A 20/1 0.540 R RCPT- RM 1902 20 21 RCPT- RM 1905, FRIDGE R 1.200 20/1 B 2011 0.360 R RCPT- RM 1902 22 23 RCPT- ROOFTOP R 1.260 20/1 C 20/1 0.360 R RCPT- RM 1902 24 25 EXTERIOR MOUNTED TV 16TH FLR - D 5.000 - 30/2 - A 20/1 0,360 R RCPT - RM 1902 26 27 I B 20/1 0.360 R RCPT- RM 1902 28 29 EXTERIOR MOUNTED TV 16TH FLR D - 5.000 - 3012 - C 20/1 0.360 R RCPT- RM 1902 30 311- A 20/1 - S SPARE 32 33 RANGE - A - 8.000 - 5012 - B 20/1 - S SPARE 34 35 C 20/1 - S SPARE 36 37 RCPT- RM 1903 R 1.080 20/1 A 1511 1.152 WH DWH-3 (WTR HTR) (LEVEL 19) 38 39 RCPT- OUTSIDE DECK R 0.900 20/1 B 15/1 1.152 WH DWH-4 (WTR HTR) (LEVEL 19) 40 41 RCPT- RM 1903, DRINKING FOUNTAIN R 1.000 20/1 C 30/1 1.920 M RCP-5 (RECIRC. PUMP) (LEVEL 18) 42 PHASE LOAD PHASE A= 17.87 KVA PHASE B= 20.62 KVA PHASE C= 17.19 KVA LOADTYPE L R M H WH HM D A K LM TOTALLOADS PANEL AR19 18.74 4.13 2.30 10.00 8.00 1.92 43.18 KVA 119.84 AMP SECTION 2 4.50 8.00 12.50 KVA 34.70 AMP CONN. LOAD 23.24 4.13 2.30 10.00. 16.00 1.92 55.68 KVA 154.54 AMP CALC. LOAD 16.62 4.13 2.30 10.00 16.00 0.48 49.54 KVA 137.50 AMP PANEL SEC 2 LOCATION: ELEC RM 19TH FLR SERVING: APARTMENT LOADS FED FROM: SECTION 1 208/120 VOLT 225 AMP MAIN LUGS ONLY 10,000 A 3 PHASE 5,160 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 43 RCPT- DECK 1901 MICROWAVE R 1.200 20/1 A 20/1 - S SPARE 44 45 RCPT- DECK 1901 FRIDGE R 1.500 2011 B 20/1 - S SPARE 46 47 RCPT DECK 1901 COFFEE R 1.800 20/1 C 20/1 - S SPARE 48 49 RANGE - A - 8.000 - 50/2 - A 2011 - S SPARE 50 51 B 20/1 - S SPARE 52 53 SPARE S - 20/1 C 20/1 - S SPARE 54 55 SPARE S - 20/1 A 20/1 - S SPARE 56 57 SPARE S - 20/1 B 20/1 - S SPARE 58 59 SPARE S - 20/1 C 20/1 - S SPARE 60 61 SPARE S - 2011 A 20/1 - S SPARE 62 63 SPARE S - 20/1 B 20/1 - S SPARE 64 65 SPARE S - 20/1 C 20/1 - S SPARE 66 67 SPARE S - 20/1 A 20/1 - S SPARE 68 69 SPARE S - 20/1 B 20/1 - S SPARE 70 71 SPARE S - 20/1 C 20/1 - S SPARE 72 73 SPARE S - 2011 A 20/1 - S SPARE 74 75 SPARE S - 20/1 B 20/1 - S SPARE 76 77 SPARE S - 20/1 C 20/1 - S SPARE 78 79 SPARE S - 20/1 A 20/1 - S SPARE 80 81 SPARE S - 20/1 B 20/1 - S SPARE 82 83 SPARE S - 20/1 Cl20/1 - S SPARE 84 PHASE LOAD PHASE A= 5.20 KVA PHASE B= 5.50 KVA PHASE C= 1.80 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 4.50 8.00 12.50 KVA 34.70 AMP CALC. LOAD 4.50 8.00 12.60 KVA 34.70 AMP REQUIRED FEED-THRU LUGS OPTIONS: J W Q Cl ao 0 N C� W tp �o O o� PANEL AR1 LOCATION: ELEC RM 1 ST FLR SERVING: APARTMENT LOADS FEDFROM: ADB(MA75KVAXFMRT-AR1) 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 225 AMP MAIN BREAKER AFC: 5,861 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 RCPT-CATVRM R 0.720 20/1 A 15/1 0.528 M EF-V7 2 3 RCPT-CATVRM R 0.720 20/1 B 15/1 0.864 M EF-V3 4 5 RCPT - MAIN RM, BIKE STORAGE R 0.900 20/1 C 15/1 0.696 M EF-V8 6 7 RCPT - RM 114,115 R 0.900 20/1 A 20/1 1.080 R RCPT- RM 244, 241, 242, 243 8 9 RCPT- RM 109, 110 R 0.900 20/1 B 20/1 1.080 R RCPT- RM 244, 241, 242, 243 10 11 RCPT - RM 103, ST 101 R 0.720 20/1 C 20/1 1.260 R RCPT - 241, 242 12 13 RCPT- RM 111 R 0.900 20/1 A 20/1 1.000 R RCPT- CEILING PROJECTOR 14 15 RCPT- RM 111 R 1.080 20/1 B 20/1 - S SPARE 16 17 RCPT- RM 112 R 0.720 20/1 C 20/1 - S SPARE 18 19 RCPT- RM 112 R 0.900 2011 A 20/1 1.000 D GARAGE GATE 20 21 RCPT - RM 112, ST 102, 100A R 0.900 20/1 B 20/1 0.180 R RCPT - AMR METER 22 23 RCPT- ELEV#4, 5, 6 PIT R 0.540 20/1 C 20/1 1.000 D GEN BATTERY CHARGER 24 25 RCPT- RM 102 R 0.900 20/1 A 20/1 1.000 D GEN. BLOCK HEATER 26 27 SPARE S - 20/1 B 20/1 1.000 D GEN. ATS CONTROLS 28 29 SPARE S - 20/1 C 20/1 - S SPARE 30 31 TELEPHONE D 0.500 20/1 A 2011 - S SPARE 32 33 CCTV D 0.500 20/1 B 20/1 - S SPARE 34 35 ACCESS CONTROL D 0.500 20/1 C 20/1 0.200 M LOUVERS (L-2, L-3) FIRE CTR/PMP RM 36 37 ACCESS CONTROL D 0.500 20/1 A 20/1 0.500 M LOUVERS (L-1, L-4, L-11, L-12, L-13) 38 39 SPARE S - 20/1 B 20/1 0.300 M LOUVERS (L-8, L-9, L-10) 40 41 SPARE S - 20/1 C 20/1 0.500 D TRASH CHUTE INTERLOCK SYS 42 PHASE LOAD PHASE A= 10.43 KVA PHASE B= 7.52 KVA PHASE C= 7.04 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 15.40 3.09 6.50 0.86 24.99 KVA 69.36 AMP CALC. LOAD 12.70 3.09 6.50 0.22 22.50 KVA 62.46 AMP NOTES: PANEL AP9 LOCATION: ELEC RM 9TH FLR SERVING: APARTMENT LOADS FED FROM: ADB 480/277 VOLT 250 AMP MAIN LUGS ONLY SCCR: 25,000 A 3 PHASE AFC: 22,052 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LTG - APT. LOBBY FLR 2-9 L 0.432 20/1 A 2011 2.484 L LTG - APT. LOBBY FLR 9-19 2 3 LTG - APT. LOBBY FLR 2-9 L 0.885 20/1 B 20/1 1.248 L LTG - APT. LOBBY FLR 1-9 4 5 SPARE S - 20/1 C 20/1 0.805 L LTG -TRASH CHUTE 6 7 SPARE S - 2011 A 20/1 1.708 L LTG - DATA, STORAGE FLR 12-18 8 9 SPARE S - 20/1 B 20/1 - S SPARE 10 11 SPARE S - 20/1 C 20/1 - S SPARE 12 13 SPARE S - 20/1 A 20/1 - S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 2011 B 20/1 - S SPARE 28 29 SPARE S - 20/1 C 20/1 - S SPARE 30 31 DWH-11-2 (WTR HTR) (LEVEL 11) - - WH - - 4.500 - - 15/3 - - A 2011 - S SPARE 32 33 B 20/1 - S SPARE 34 35 C 20/1 - S SPARE 36 37 DWH-6-2 (WTR HTR) (LEVEL 6) - - WH - - 4.500 - - 15/3 - - A 100/3 - - 61.800 - - P - - PANEL AR9 (VIA 75KVA XFMR T-AR9) - - 38 39 B 40 41 C 42 PHASE LOAD PHASE A= 20.41 KVA PHASE B= 32.64 KVA PHASE C= 25.31 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 7.56 25.20 23.60 9.00 13.00 11.80 78.36 KVA 94.25 AMP CALC. LOAD 9.45 17.60 23.60 9.00 13.00 2.95 75.60 KVA 90.94 AMP NOTES: PANEL AR9 LOCATION: ELEC RM 9TH FLR SERVING: APARTMENT LOADS FED FROM: AP9 (VIA75KVAXFMR T-AR9) 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 225 AMP MAIN BREAKER AFC: 3,365 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 RCPT- DATA RACKS (LEVELS 2 & 3) D 0.500 20/1 A 20/1 0.500 D RCPT- DATA RACKS (LEVELS 10 & 11) 2 3 RCPT- DATA RACKS (LEVELS 4 & 5) D 0.500 20/1 B 20/1 5.000 D RCPT - DATA RACKS (LEVELS 12 & 13) 4 5 RCPT- DATA RACKS (LEVELS 6 & 7) D 0.500 20/1 C 20/1 0.500 D RCPT - DATA RACKS (LEVELS 14 & 15) 6 7 RCPT- DATA RACKS (LEVELS 8 & 9) D 0.500 20/1 A 20/1 0.500 D RCPT- DATA RACKS (LEVELS 16 & 17) 8 9 RCPT- DATA RACKS (LEVELS 2 & 3) D 0.500 20/1 B 20/1 0.250 D RCPT - DATA RACKS (LEVEL 18) 10 11 RCPT- DATARACKS (LEVELS 4 & 5) D 0.500 20/1 C 20/1 0.500 D RCPT- DATA RACKS (LEVELS 10 & 11) 12 13 RCPT- DATA RACKS (LEVELS 6 & 7) D 0.500 20/1 A 20/1 0.500 D RCPT- DATA RACKS (LEVELS 12 & 13) 14 15 RCPT- DATA RACKS (LEVELS 8 & 9) D 0.500 20/1 B 1 20/1 0.500 D RCPT - DATA RACKS (LEVELS 14 & 15) 16 17 SPARE S - 20/1 C 20/1 0.500 D RCPT - DATA RACKS (LEVELS 16 & 17) 18 19 RCPT -RES, ELEV LOBBY 10-19 R 1.800 20/1 A 20/1 0.250 D RCPT-DATA RACKS (LEVEL 18) 20 21 RCPT- WEST CORRIDOR 10-18 R 1.620 20/1 B 20/1 1.260 R RCPT- EAST CORRIDOR 10-18 22 23 RCPT-WEST CORRIDOR 10-18 R 1.620 20/1 C 20/1 1.260 R RCPT-EAST CORRIDOR 10-18 24 25 RCPT- WEST CORRIDOR 10-18. R 1.620 20/1 A 20/1 1.260 R RCPT- EAST CORRIDOR 10-18 26 27 RCPT-WEST CORRIDOR 10-18 R 1.620 20/1 B 20/1 1.260 R RCPT-EAST CORRIDOR 10-18 28 29 RCPT- WEST CORRIDOR 10-18 R 1.620 20/1 C 20/1 1.260 R RCPT- NORTH STAIRWELL 10-19 30 31 RCPT- ELEC RM 10-19 R 1.620 .20/1 A 20/1 1.800 R RCPT- WEST CORRIDOR 2-9 32 33 RCPT- ELEC RM 3-9 R 1.260 20/1 B 20/1 1.440 R RCPT- WEST CORRIDOR 2-9 34 35 SPARE S - 20/1 C 20/1 1.440 R RCPT-WEST CORRIDOR 2-9 36 37 SPARE S - 20/1 A 20/1 1.440 R RCPT- RES. ELEV LOBBY 2-9 38 39 SPARE S - 20/1 B 20/1 - S SPARE 40 41 SPARE S - 20/1 C 20/1 - S SPARE 42 43 SPARE S - 20/1 A j 20/1 - S SPARE 44 45 SPARE S - 20/1 B 20/1 - S SPARE 46 47 SPARE S - 20/1 C 20/1 - S SPARE 48 49 SPARE S - 20/1 A 20/1 - S SPARE 50 51 SPARE S - 20/1 B 20/1 - S SPARE 52 53 SPARE S - 20/1 C 20/1 - S SPARE 54 55 SPARE S - 20/1 A 20/1 - S SPARE 56 57 RCP-7 (RECIRC. PUMP) (LEVEL 11) M 11.800 20/1 B 20/1 - S SPARE 58 59 RCP-6 (RECIRC. PUMP) (LEVEL 6) M 11.800 20/1 C 20/1 - S SPARE 60 PHASE LOAD PHASE A= 12.79 KVA PHASE B= 27.51 KVA PHASE C= 21.50 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 25.20 23.60 13.00 11.80 61.80 KVA 171.54 AMP CALC. LOAD 17.60 23.60 13.00 2.95 57.15 KVA 158.63 AMP NOTES: PANEL ADB LOCATION: ELEC RM 1 ST FLR SERVING: APARTMENT LOADS FED FROM: MSB 480/277 VOLT 1600 AMP MAIN LUGS ONLY SCCR: 65,000 A 3 PHASE AFC: 56,618 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 PANEL GP - P - - 38.872 - - 125/3 - - A 200/3 - 78.362 - P - PANEL AP9 - 2 3 B 4 5 C 7 PANEL AP19 - - P - - 238.564 - - 400/3 - - A 100/3 - - 24.988 - - P - - PANEL AR1 (VIA75KVAXFMR T-AR1) - - 8 9 B 10 11 C 12 13 PANEL AP1 - - P - - 89.608 - - 250/3 - - A 100/3 - - 11.987 - - P - - PANEL AL1 - - 14 15 B 16 17 C 18 19 PANELAX1 (VIA800AATS-1) - - P - 624.479 - - 800/3 - - A 200/3 - - - - - S - - SPARE - 20 21 B 22 23 C 24 25 SPARE - - S - - - - - 100/3 - - A 250/3 - - - - - S - - SPARE - 26 27 B .28 29 C 30 PHASE LOAD PHASE A= 382.68 KVA PHASE B= 371.80 KVA PHASE C= 352.38 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL ADB KVA AMP PANEL GP 6.41 1.26 31.20 38.87 KVA 46.76 AMP PANEL AP9 7.56 25.20 23.60 9.00 13.00 11.80 78.36 KVA 94.25 AMP PANEL AP19 2.97 23.24 173.18 6.37 6.80 10.00 16.00 26.60 238.56 KVA 286.95 AMP PANELAR1 15.40 3.09 6.50 0.86 24.99 KVA 30.06 AMP PANELAPI 63.13 26.48 11.63 89.61 KVA 107.78 AMP PANELAL1 11.99 11.99 KVA 14.42 AMP PANEL AX1 47.14 2.16 548.48 1.00 25.70 43.23 624.48 KVA 751.13 AMP CONN. LOAD 76.07 67.26 811.47 33.85 15.80 86.40 16.00 43.23 1,106.86 KVA 1,331.35 AMP CALC. LOAD 95.09 38.63 811.47 33.85 15.80 86.40 16.00 10.81 1,108.06 KVA 1,332.78 AMP NOTES: PANEL AL1 LOCATION: ELEC RM 1 ST FLR SERVING: LIGHTING FED FROM: ADB 480/277 VOLT 125 AMP MAIN LUGS ONLY SCCR: 50,000 A 3 PHASE AFC: 40,424 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LTG - RM 101, 102, 104, 105, 106 L 0.976 20/1 A 1 1 20/1 3.548 L LTG - STORAGE, OFFICE 2ND FLR 2 3 LTG - APARTMENT LOBBY L 2.230 20/1 B 20/1 0.679 L LTG - GARAGE ACCESS LANE 4 5 LTG - ELEV PIT L 0.366 20/1 C 20/1 1.824 L LTG -WEST SITE (NOTE 1) 6 7 LTG - BUILDING EXTERIOR (NOTE 1) L 0.540 20/1 A 20/1 - S SPARE 8 9 SPARE S - 20/1 B 20/1 1.824 L LTG - SOUTH SITE (NOTE 1) 10 11 SPARE S - 20/1 C 20/1 - S SPARE 12 13 SPARE S - 20/1 A 20/1 - S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE. 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 20/1 B 20/1 - S SPARE 28 29 SPARE S - 20/1 C 20/1 - S SPARE 30 PHASE LOAD PHASE A= 5.06 KVA PHASE B= 4.73 KVA PHASE C= 2.19 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 11.99 11.99 KVA 14.42 AMP CALC. LOAD 14.98 14.98 KVA 18.02 AMP NOTES: 1.) ROUTE VIA LIGHITNG CONTROL PAN EL'LCP-A'. PANEL API LOCATION: ELEC RM 1ST FLR SERVING: APARTMENT MECHANICAL LOADS FED FROM: ADB 480/277 VOLT 250 AMP MAIN LUGS ONLY SCCR: 65,000 A 3 PHASE AFC:.53,967 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 WSHP-I-5A M 2.742 15/1 A 15/3 - - 9.473 - - M - - WSHP-1-IA - - 2 3 SPARE S - 15/1 B 4 5 UH-2A H 3.186 20/1 6 7 UH-2B H 3.186 20/1 A HC 15/3 - - 9.473 - - M - - WSHP-1-2A - - 8 9 UH-3 H 4.183 20/1 B 10 11 U H-7 H 2.188 20/1 12 13 UH-8 H 2.188 20/1 A 15/3 - - 9.473 - - M - - WSHP-1-3A - - 14 15 UH-9 H 3.185 20/1 B 16 17 UH-10A H 4.183 20/1 C 18 19 UH-10B H 4.183 20/1 A 15/3 - - 4.737 - - M - - WSHP-14A - - 20 21 SPARE S - 20/1 B 22 23 SPARE S - 20/1 C 24 25 SPARE S - 20/1 A 15/3 - - 5.817 - - M - WSHP-1-6A - 26 27 SPARE S - 20/1 B 29 SPARE S - 20/1 dc 30 31 SPARE S - 20/1 A 15/1 2.742 M WSHP-1-7A 32 33 SPARE S - 20/1 B 1511 - S SPARE 34 35 SPARE S - 20/1 C 15/1 1.551 M WSHP-2-1A 36 37 SPARE S - 20/1 A 15/1 2.742 M WSHP-2-2A 38 39 SPARE S - 20/1 B 15/1 2.742 M WSHP-2-3A 40 41 SPARE S - 20/1 C 15/1 - S SPARE 42 43 SPARE S - 20/1 A 15/1 - S SPARE 44 45 SPARE S - 20/1 B 15/1 - S SPARE 46 47 SPARE S - 20/1 C 15/1 - S SPARE 48 49 SPARE S - 20/1 A 20/1 - S SPARE 50 51 SPARE S - 20/1 B 20/1 - S SPARE 52 53 SPARE S - 20/1 C 20/1 - S SPARE 54 55 TRASH COMPACTOR (10HP) (EXTERIOR) - M - - 11.634 - - 25/3 - - A 20/1 - S SPARE 56 57 B 20/1 - S SPARE 58 59 C 20/1 - t-s SPARE 60 PHASE LOAD PHASE A= 34.65 KVA PHASE B= 26.98 KVA PHASE C= 27.98 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 63.13 26.48 11.63 89.61 KVA 107.78 AMP CALC. LOAD 63.13 26.48 2.911 8 AMP NOTES: H f L1�-68�1`] RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER UEL 0 3 2015 City Of Tukwila PANEL PANEL NAME PANEL NAME PANEL NAME AP19 AR1 ADB AR19 AP9 AL1 - AR9 AP1 0 N 0 ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB :YPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry w 3: 0 w ~ Y z aLs 0 >J pY (DQ I- z M N T� N VJ CONSULTANT :GISTRATION GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826.4446 SHEET TITLE AND NUMBER ELECTRICAL PANEL SCHEDULES E8.02 PANEL HX1 LOCATION: ELEC RM 1 ST FLR SERVING: HOTEL EMERGENCY LOADS FED FROM: AX1 480/277 VOLT 250 AMP MAIN LUGS ONLY SCCR: 14,000 A 3 PHASE AFC: 12,875 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LTG - EGRESS HTL CANOPY (NOTE 1) L 0.270 20/1 A 20/1 3.556 L LTG - EGRESS HOTEL FLR 2-11 2 3 LTG - EGRESS HTL EXTER. (NOTE 1) L 0.252 20/1 B 20/1 3.339 L LTG- EGRESS HOTEL FLR 2-11 4 5 LTG - EGRESS 1 ST FLR CORRIDORS L 1.062 20/1 C 20/1 0.671 L LTG - EGRESS HOTEL FLR 1-11 6 7 LTG - EM 1 ST FLR ROOMS L 0.984 20/1 A 20/1 0.732 L LTG - EGRESS HOTEL FLR 1-11 8 9 LTG - EM POOL ROOM L 0.384 20/1 B 20/1 1.514 L LTG - EGRESS 2ND FLR CORRIDORS 10 11 SPARE S - 20/1 C 20/1 0.349 L LTG - EM 2ND FLR ROOMS 12 13 SPARE S - 20/1 A 20/1 0.833 L LTG - EM 2ND FLR MEETING RMS 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 2011 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 20/1 B 20/1 - S SPARE 28 29 SPARE S - 20/1 C 20/1 - S SPARE 30 31 SPARE S - 20/1 A 20/1 - S SPARE 32 33 SPARE S - 20/1 B 2011 - S SPARE 34 35 SPARE S - 20/1 C 20/1 - S SPARE 36 37 SPARE S - 20/1 A 30/3 - - 0.000 - - D - - SPD (SURGE PROTECTIVE DEVICE) - - 38 39 SPARE S - 20/1 B 40 41 SPARE S - 20/1 C 42 PHASE LOAD PHASE A= 6.38 KVA PHASE B= 5.49 KVA PHASE C= 2.08 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 13.95 0.00 13.95 KVA 16.77 AMP CALC. LOAD 17.43 0.00 17.43 KVA 20.97 AMP NOTES: 1.) ROUTE VIA UL-924 TRANSFER DEVICE. TRANSFER DEVICE CONTROL INPUT SHALL FOLLOW NORMAL LIGHTING CONTROL VIA LCP. PANEL AX5 LOCATION: ELECT / CATV RM 500E SERVING: EM LOADS (CORRIDOR SMOKE EXHAUST) FED FROM: AX1 480/277 VOLT 250 AMP MAIN LUGS ONLY SCCR: 18,000 A 3 PHASE AFC: 16,938 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 PF-CD1 - - M - - 9.145 - - 20/3 - - A 1 20/1 - S SPARE 2 3 B 20/1 - S SPARE 4 5 C 20/1 1 - S SPARE 6 7 PF-CD2 - - M - 9.145 - - 20/3 - - A 20/1 - S SPARE 8 9 B 20/1 - S SPARE 10 11 C 20/1 - S SPARE 12 13 PF-CD3 - - M - - 9.145 - - 20/3 - - A 20/1 - S SPARE 14 15 B 20/1 - S SPARE 16 17 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 2011 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 20/1 B 20/1 - S SPARE 28 29 SPARE S - 20/1 C 20/1 - S SPARE 30 31 SPARE S - 20/1 A 20/1 - S SPARE 32 33 SPARE S - 20/1 B 20/1 - S SPARE 34 35 SPARE S - 20/1 C 20/1 - S SPARE 36 37 SPD (SURGE PROTECTIVE DEVICE) - - D - - 0.000 - - 30/3 - - A 60/3 -- - 2.300 - P - - PANEL ARX5 (VIA30KVAXFMR T-ARX5) - - 38 39 40 41 Ic 42 PHASE LOAD PHASE A= 51.15 KVA PHASE B= 45.10 KVA PHASE C= 47.02 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS; PANEL AX5 27.44 0.00 9.15 27.44 KVA 33.00 AMP PANEL AX7 19.53 84.10 9.90 9.15 113.53 KVA 136.56 AMP PANEL ARX5 0.30 1 1 2.00 0.30 2.30 KVA 2.77 AMP CONN. LOAD 19.53 111.84 11.90 9.15 143.27 KVA 172.32 AMP CALC. LOAD 24.42 111.84 11.90 2.29 150.44 KVA 180.95 AMP REQUIRED FEED-THRU LUGS A)47 OPTIONS: NOTES: PANEL ARX5 LOCATION: ELECT / CAN RM 500E SERVING: EM LOADS (CORRIDOR SMOKE EXHAUST) FED FROM: AX5 (VIA 30KVAXFMR T-ARX5) 208/120 VOLT 100 AMP BUS RATING SCCR: 10,000 A 3 PHASE 100 AMP MAIN BREAKER AFC: 1,821 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 SPARE S - 20/1 A 20/1 0.500 D FIRE ALARM BOOSTER 2 3 SPARE S - 20/1 B 20/1 0.500 D FIRE ALARM BOOSTER 4 5 SPARE S - 20/1 C 20/1 0.500 D FIRE ALARM BOOSTER 6 7 SPARE S - 20/1 A 20/1 0.500 D FIRE ALARM BOOSTER 8 9 SPARE S - 20/1 B 20/1 - S SPARE 10 11 SPARE S - 20/1 C 20/1 - S SPARE 12 13 SPARE S - 20/1 A 20/1 - S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 30/3 - 0.000 - D - - SPD (SURGE PROTECTIVE DEVICE) - - 26 27 SPARE S - 20/1 B 28 29 COR. EXH. LOUVERS (L-1 4,L-1 5,L-1 6) M 0.300 20/1 1 30 PHASE LOAD PHASE A= 1.00 KVA PHASE B= 0.50 KVA PHASE C= 0.80 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 0.30 2.00 0.30 2.30 KVA 6.38 AMP CALC. LOAD 0.30 2.00 0.08 2.38 KVA 6.59 AMP NOTES: rn 3 0 W U V) J W Z N Qo ao cxi� wt 1N O � o� �o PANEL AXI LOCATION: ELEC RM 1ST FLR SERVING: EMERGENCYLOADS FED FROM: ADB (MA800AATS-1) 480/277 VOLT 1200 AMP MAIN LUGS ONLY SCCR: 65,000 A 3 PHASE AFC: 47,301 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT DBS-1 (DOM. BOOSTER PUMPS) 15 HP (LEVEL 1 FIRE PUMP RM) - M - - 17.500 - - 40/3 - - A 15/3 - - 6.316 - - M - - JOCKEY PUMP (5 HP) (LEVEL 1 FIRE PUMP RM) - 2 3 B 4 5 C 6 7 PANEL AX1 L - - P - - 3.765 - - 60/3 - - A 125/3 - - 13.700 - - P - - PANEL AXG (GARAGE EM) - - 8 9 B 10 11 C 12 13 PANEL ARX1 (VIA 45KVA XFMR T-ARX1) - - P - - 13.880 - - 100/3 - - A 250/3 - - 143.268 - - P - - PANEL AX5 - - 14 15 B 16 17 C 18 19 PANEL HX1 - - P - - 13.946 - - 200/3 - - A 30/3 - - 0.000 - - D - - SPD (SURGE PROTECTIVE DEVICE) - 20 21 B 22 23 C 24 PHASE LOAD PHASE A= 213.79 KVA PHASE B= 209.20 KVA PHASE C= 201.49 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL AX1 23.82 0.00 17.50 23.82 KVA 28.65 AMP PANEL AX1 L 3.77 0.00 3.77 KVA 4.53 AMP PANEL AXG 6.38 6.32 1.00 0.00 6.32 13.70 KVA 16.48 AMP PANEL ARX1 1.08 12.80 13.88 KVA 16.70 AMP PANEL AX5 19.53 111.84 11.90 9.15 143.27 KVA 172.32 AMP PANEL HX1 13.95 0.00 13.95 KVA 16.77 AMP PANEL AX19 3.52 1.08 406.51 1.00 43.23 412.10 KVA 495.68 AMP CONN. LOAD 47.14 2.16 548.48 1.00 25.70 43.23 624.48 KVA 751.13 AMP CALC. LOAD 58.93 2.16 548.48 1.00 25.70 10.81 647.07 KVA 778.31 AMP REQUIRED FEED-THRU LUGS OPTIONS: NOTES: FEED-THRU LUGS SUPPLIES PANEL AX19. PANEL AX1 L LOCATION: ELEC RM 1 ST FLR SERVING: EMERGENCY LOADS FED FROM: AX1 480/277 VOLT 125 AMP MAIN LUGS ONLY SCCR: 18,000 A 3 PHASE AFC: 15,117 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 SPARE S - 20/1 A -20/1 0.610 L LTG - EM ELEC RM/FIRE PUMP ROOM 2 3 SPARE S - 20/1 1 B 1 20/1 1.703 L LTG- EGRESS 1ST FLR CORRIDORS 4 5 SPARE S - 20/1 C 20/1 0.450 L LTG- EGRESS BLDG EXTER. (NOTE 1) 6 7 SPARE S - 20/1 A 20/1 0.366 L LTG- HOTEL SPA UNFINISHED SPACE 8 9 SPARE S - 20/1 B 20/1 0.236 L LTG - GARAGE ACCESS LANE VEST 10 11 SPARE S - 20/1 C 20/1 0.089 L LTG - EMERGENCY 1ST FLR ROOMS 12 13 SPARE S - 20/1 A 20/1 0.311 L LTG - EM 2ND FLOOR STORAGE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPD (SURGE PROTECTIVE DEVICE) - D - - 0.000 - - 30/3 - - A 20/1 - S SPARE 26 27 B 20/1 - S SPARE 28 291- C 2011 - S SPARE 30 PHASE LOAD PHASE A= 1.29 KVA PHASE B= 1.94 KVA PHASE C= 0.54 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 3.77 0.00 3.77 KVA 4.53 AMP CALC. LOAD 4.71 0.00 4.71 KVA 5.66 AMP NOTES: 1.) ROUTE VIA UL-924 TRANSFER DEVICE. TRANSFER DEVICE CONTROL INPUT SHALL FOLLOW NORMAL LIGHTING CONTROL VIA LCP. PANEL ARXi LOCATION: ELEC RM 1 ST FLR SERVING: EMERGENCY LOADS FED FROM: AX1 (MA45KVAXFMRT-ARX1) 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 150 AMP MAIN BREAKER AFC: 3,453 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 FIRE SMOKE DAMPERS FLRS 1-5 D 0.500 20/1 A 20/1 0.500 D FIRE ALARM BOOSTER 2 3 FIRE SMOKE DAMPERS FLRS 6-10 D 0.400 20/1 B 20/1 0.500 D FIRE ALARM BOOSTER 4 5 FIRE SMOKE DAMPERS FLRS 11-14 D 0.400 20/1 C 20/1 0.500 D FIRE ALARM BOOSTER 6 7 FIRE SMOKE DAMPERS FLRS 15-18 D 0.400 20/1 A 20/1 0.500 D FIRE ALARM BOOSTER 8 9 FIRE ALARM PANEL D 0.500 20/1 B 20/1 0.500 D FIRE ALARM BOOSTER 10 11 FIRE ALARM PANEL D 0.500 20/1 C 20/1 0.500 D FIRE ALARM BOOSTER 12 13 FIRE ALARM PANEL D 0.500 20/1 A 20/1 0.500 D FIRE ALARM BOOSTER 14 15 RCPT- FIRE COMMAND CENTER R 1.080 20/1 B 20/1 0.500 D FIRE ALARM BOOSTER 16 17 SPARE S - 20/1 C 20/1 0.500 D FIRE ALARM BOOSTER 18 19 SPARE S - 20/1 A 20/1 0.500 D FIRE ALARM BOOSTER 20 21 SPARE S - 20/1 B 20/1 0.500 D FIRE ALARM BOOSTER 22 23 SPARE S - 20/1 C 20/1 0.500 D FIRE ALARM BOOSTER 24 25 SPARE S - 20/1 A 20/1 0.500 D FIRE ALARM BOOSTER 26 27 SPARE S - 20/1 B 20/1 0.500 D FIRE ALARM BOOSTER 28 29 SPARE S - 20/1 C 20/1 0.500 D FIRE ALARM BOOSTER 30 31 SPARE S - 20/1 A 2011 0.500 D FIRE ALARM BOOSTER 32 33 SPARE S - 20/1 B 20/1 0.500 D FIRE ALARM BOOSTER 34 35 SPARE S - 20/1 C 20/1 0.500 D FIRE ALARM BOOSTER 36 37 SPD (SURGE PROTECTIVE DEVICE) - - D - 0.000 - 30/3 - A 20/1 - S SPARE 38 39 B 20/1 - S SPARE 40 41 0.600 D FIRE SMOKE DAMPERS (LEVELS 1&2) 42 PHASE LOAD PHASE A= 4.40 KVA PHASE B= 4.98 KVA PHASE C= 4.50 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 1.08 12.80 13.88 KVA 38.53 AMP CALC. LOAD 1.08 12.80 13.88 KVA 38.53 AMP NOTES: s PANEL G P LOCATION: SERVING: FEDFROM: GARAGE GARAGE LOADS ADB 480/277 VOLT 3 PHASE 4 WIRE 125 AMP MAIN LUGS ONLY SCCR: 14,000 A AFC: 7,083 A MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LTG - GARAGE LVL 1,2 L 3.520 20/1 A 20/1 - S SPARE 2 3 LTG - GARAGE LVL 3,4 L 1.980 20/1 B 2011 - S SPARE 4 5 LTG - GARAGE EXT L 0.912 20/1 C 2011 - S SPARE 6 7 SPARE S - 20/1 A 2011 - S SPARE 8 9 SPARE S - 20/1 B 20/1 - S SPARE 10 11 SPARE S - 20/1 C 20/1 - S SPARE 12 13 SPARE S - 20/1 A 20/1 - S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 60/3 - - 32.460 - - P - PANEL GR - - (VIA 30KVA XFMR T-GR) 26 27 SPARE S - 20/1 B 28 29 SPARE S - 20/1 C 30 PHASE LOAD PHASE A= 16.00 KVA PHASE B= 11.34 KVA PHASE C= 11.53 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL GP 6.41 6.41 KVA 7.71 AMP PANEL GR 1.26 31.20 32.46 KVA 39.04 AMP CONN. LOAD 6.41 1.26 31.20 38.87 KVA 46.76 AMP CALC. LOAD 8.02 1.26 31.20 40.48 KVA 48.68 AMP NOTES: PANEL GR LOCATION: GARAGE SERVING: GARAGE LOADS FED FROM: GP (VIA30KVAXFMR T-GR) 208/120 VOLT 100 AMP BUS RATING SCCR: 10,000 A 3 PHASE 100 AMP MAIN BREAKER AFC: 1,708 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 CAR CHARGING STATION - D - 6.240 - 40/2 - A 40/2 - 6.240 - D - CAR CHARGING STATION - 2 3 B 4 5 CAR CHARGING STATION - D - 6.240 - 40/2 - C 40/2 - 6.240 - D - CAR CHARGING STATION - 6 7 A 8 9 CAR CHARGING STATION - D - 6.240 - 40/2 - B 2011 - S SPARE 10 11 C 20/1 - S SPARE 12 13 SPARE S - 20/1 A 20/1 - S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 ISPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 20/1 B 20/1 - S SPARE 28 29 SPARE S - 20/1 C 20/1 1.260 R RCPT - LEVELS 1 - 4 30 PHASE LOAD PHASE A= 12.48 KVA PHASE B= 9.36 KVA PHASE C= 10.62 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 1.26 31.20 32.46 KVA 90.10 AMP CALC. LOAD 1.26 31.20 32.46 KVA 90.10 AMP NOTES: PANEL AXG LOCATION: PARKING GARAGE SERVING: GARAGE EMERGENCY LOADS FED FROM: AX1 4801277 VOLT 125 AMP MAIN LUGS ONLY SCCR: 14,000 A 3 PHASE AFC: 7,412 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 EM LTS - GARAGE L 1.760 20/1 A 20/2 - 1.368 - L - EM LTG - GARAGE LVL 4 (POLES) - 2 3 EM LTS - GARAGE L 2.966 20/1 B 4 5 EM LTS - GARAGE EXT. L 0.288 20/1 C 20/1 - S SPARE 6 7 SPARE S - 20/1 A 20/1 - S SPARE 8 9 SPARE S - 20/1 B 20/1 - S SPARE 10 11 SPARE S - 20/1 C 20/1 - S SPARE 12 13 SPARE S - 20/1 A 20/1 - S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 COMPRESSOR (FIRE SPRINKLER) - - M - - 6.318 - - 15/3 - - B 20/1 - S SPARE 22 23 C 2011 - S SPARE 24 25 A 30/3 - - 0.000 - - D - - SPD (SURGE PROTECTIVE DEVICE) - - 26 27 PANEL ARXG (VIA 1 5KVA T-ARXG) - P - 1.000 - 40/2 - B 28 29 1: C 30 PHASE LOAD PHASE A= 5.22 KVA PHASE B= 5.92 KVA PHASE C= 2.56 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL AXG 6.38 6.32 0.00 6.32 12.70 KVA 15.28 AMP PANEL ARXG 1.00 0.00 1.00 KVA 1.20 AMP CONN. LOAD 6.38 6.32 1.00 0.00 1 6.32 13.70 KVA 16.48 AMP CALC. LOAD 7.98 6.32 1.00 0.00 1.58 16.88 KVA 20.30 AMP NOTES: PANEL ARXG LOCATION: PARKING GARAGE SERVING: GARAGE EMERGENCY240/120V LOADS FED FROM: AXG (VIA 15KVAXFMR T ARXG) 240/120 VOLT 100 AMP BUS RATING SCCR: 10,000 A 1 PHASE 60 AMP MAIN BREAKER AFC: 1,843 A 3 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 UNIT HEATER H 1.000 20/1 A 20/1 - S SPARE 2 3 SPARE S - 20/1 B 2011 - S SPARE 4 5 SPARE S - 20/1 A 20/1 - S SPARE 6 7 SPARE S - 20/1 B 30/2 - 0.000 - D - SPD (SURGE PROTECTIVE DEVICE) - 8 9 SPARE S - 20/1 A 10 PHASE LOAD PHASE A= 1.00 KVA PHASE B= 0.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS, CONN. LOAD 1.00 0.00 1.00 KVA 4.17 AMP CALC. LOAD 1.00 0.00:00 KVA 4.17 AMP NOTES: PANEL IS 10KVA MINI POWER ZONE (480-240/120V, 1-PHASE,10 KVA TRANSFORMER WITH 50A S °" IE qN'GER PANEL NFPA 70 a NEG K RECEIVED CITY OF TUICWILA OCT 15 2015 PERMIT CENTER UL+ U c3 LU IJ City of Tukwila BUILDING DIVISR , PANEL SCHEDULE INDEX PANEL NAME PANEL NAME PANEL NAME HX1 AX1 GP AX5 AX1 L GR ARX5 ARX1 AXG - - ARXG ISSUE 0 Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROV ED BY: DRAWN B Y: JAB KEYPLAN PHASE ' ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT W 3: 0 w Q Q z a� � Q IllJ pY 0 Q F- z M N V ) >ULTANT STRATION J1©NAL �'T 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826.4446 SHEET TITLE AND NUMBER ELECTRICAL PANEL SCHEDULES E8.03 rn i U) J 0 w U PANEL LOCATION: ELEC RM 19TH FLR SERVING: EMERGENCY LOADS(C0f--,R00k tMlk� CA(A) FED FROM: AX1 ; _ - .- - • = 480/277 VOLT 800 AMP MAIN LUGS ONLY SCCR: 35,000 A 3 PHASE AFC: 22,645 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 PF-HE1 - - M - - I- 17.459 - 30/3 - - A 40/3 - - 22.437 - - I- M - PF-AEI - - 2 3 B 4 5 C 6 7 PF-HE2 - - M - - 17.459 - - 30/3 - - A 40/3 - - 22.437 - - M - - PF-AE2 - - 8 9 B 10 11 C 12 13 PF-HE3 - - M - - 17.459 - - 30/3 - - A 40/3 - - 22.437 - - M - - PF-AE3 - - 14 15 B 16 17 C 18 19 SPARE - - S - - - - - 60/3 - - A 20/3 - - 9.145 - - M - - PF-S1 - - 20 21 B 22 23 C 24 25 SPARE - - S - - - - - 60/3 - - A 2013 - - 9,145 - - M - - PF-S2 - 26 27 8 28 29 C 30 31 SPARE S - 20/1 A 20/3 - - 9.145 - - M - - PF-S3 - - 32 33 SPARE S - 20/1 B 34 35 SPARE S - 20/1 C 36 37 SPARE S - 20/1 A 20/1 0.500 D FIRE ALARM BOOSTER 38 39 SPARE S - 20/1 B 20/1 0.500 D FIRE ALARM BOOSTER 40 41 SPARE S - 20/1 C 20/1 - S SPARE 42 43 LTG - EGRESS 18TH FLR L 0.405 20/1 A 20/1 - S SPARE 44 45 LTG - EGRESS 18TH FLR L 0.351 20/1 B 20/1 - S SPARE 46 47 LTG -EGRESS APT. CLUB/LOUNGE L 0.949 20/1 C 20/1 - S SPARE 48 49 PANEL ELEV-1,2,3 - - P - - 129.693 - - 40013 - - A 60/3 - - 2.890 - - P - - PNL ARX19(VIA30KVAXFMRT-ARX19) - 50 51 B 52 53 C 54 55 PANEL ELEV-4,5,6 - - P - - 129.693 - - 400/3 - - A 30/3 - - 0.000 - - D - - SPD (SURGE PROTECTIVE DEVICE) - - 56 57 B 58 59 C 60 PHASE LOAD PHASE A= 137.42 KVA PHASE B= 137.83 KVA PHASE C= 136.85 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL AX19 1.71 147.12 1.00 22.44 149.83 KVA 180.22 AMP PANEL ARX19 1.81 1.08 0.00 2.89 KVA 3.48 AMP PANEL ELEV 1,2,3 129.69 0.00 43.23 129.69 KVA 156.00 AMP PANELELEV4,5,6 129.69 0.00 43.23 129.69 KVA 156.00 AMP CONN. LOAD 3.52 1.08 406.51 1.00 43.23 412.10 KVA 495.68 AMP CALC. LOAD 4.39 1.08 406.51 1.00 10.81 423.79 KVA 509.74 AMP NOTES: PANEL ELEV LOCATION: ELEVATOR MACHINE ROOM SERVING- ELEVATOR MACHINE RM POWER FED FROM: ARX19 it 208/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 1,824 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA AIP PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LTG- ELEVMACHINE RM L 0.610 20/1 A 20/1 0.200 L ELEVCAB LIGHTING 2 3 RCPT - RM 2001 R 1.080 20/1 B 20/1- 0.200 L ELEV CAB LIGHTING 4 5 SPARE S - 20/1 C 20/1 0.200 L ELEV CAB LIGHTING 6 7 SPARE S - 20/1 A 20/1 0.200 L ELEV CAB LIGHTING 8 9 SPARE S - 20/1 B 20/1 0.200 L ELEV CAB LIGHTING 10 11 SPARE S - 20/1 C 2011 0.200 L ELEV CAB LIGHTING 12 13 SPARE S - 20/1 A 20/1 - S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 2011 - S SPARE 24 25 SPARE S - 20/1 A 30/3 - - 0.000 - - D - - SPD (SURGE PROTECTIVE DEVICE) - 26 27 SPARE S - 20/1 B F 28 29 SPARE S - 20/1 30 PHASE LOAD PHASE A= 1.01 KVA PHASE B= 1.48 KVA PHASE C= 0.40 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 1.81 1.08 0.00 2.89 KVA 8.02 AMP CALC. LOAD 2.26 1.08 0.00 3.34 KVA 9.28 AMP NOTES: PANEL ELEV-1,2,3 LOCATION: ELEVATOR MACHINE ROOM SERVING: ELEVATORS!, 2,3 FED FROM: AX19 480/277 VOLT 400 AMP MAIN LUGS ONLY SCCR: 35,000 A 3 PHASE AFC: 21,325 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 ELEVATOR #1 (40 HP) - M - - 43.231 - - 100/3 - - A 100/3 - - 43.231 - - M - - ELEVATOR #2 (40 HP) - - 2 3 B 4 5 C 6 7 ELEVATOR #3 (40 HP) - - M - - 43.231 - - 100/3 - - A 30/3 - - 0.000 - - D - - SPD (SURGE PROTECTIVE DEVICE) - - 8 9 B 10 11 C 12 PHASE LOAD PHASE A= 43.23 KVA PHASE B= 43.23 KVA PHASE C= 43.23 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 129.69 0.00 43.23 129.69 KVA 156.00 AMP CALC. LOAD 129.69 0.00 10.81 140.50 KVA 169.00 AMP NOTES: BUSSMANN FUSIBLE PANELBOARD WITH BRANCH FUSES. PANEL ELEV-4,5,6 LOCATION: ELEVATOR MACHINE ROOM SERVING: ELEVATORS 4, 5, 6 FED FROM: AX19 480/277 VOLT 400 AMP MAIN LUGS ONLY SCCR: 35,000 A 3 PHASE AFC: 21,325 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 ELEVATOR #4 (40 HP) - - M - - 43.231 - - 100/3 - - A 100/3 - - 43.231 - - M - - ELEVATOR #5 (40 HP) - 2 3 B 4 5 C 6 7 ELEVATOR #6 (40 HP) - - M - - 43.231 - - 10013 - - A 30/3 - - 0.000 - - D - - SPD (SURGE PROTECTIVE DEVICE) - - 8 9 B 10 11 C 12 PHASE LOAD PHASE A= 43.23 KVA PHASE B= 43.23 KVA PHASE C= 43.23 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 129.69 0.00 43.23 129.69 KVA 156.00 AMP CALC. LOAD 129.69 0.00 10.81 140.50 KVA 169.00 AMP NOTES: BUSSMANN FUSIBLE PANELBOARD WITH BRANCH FUSES. PANEL ARX1 1 LOCATION: ELECT / CAN RM 1100E SERVING: EM LOADS (CORRIDOR SMOKE EXHAUST) FEDFROM: AX5 (MA30KVAXFMR T-ARX11) 208/120 VOLT 100 AMP BUS RATING SCCR: 10,000 A 3 PHASE 100 AMP MAIN BREAKER AFC: 1,798 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 FIRE SMOKE DAMPERS FLRS 9-12 D 0.400 20/1 A 20/1 0.500 D FIRE ALARM BOOSTER 2 3 FIRE SMOKE DAMPERS FLRS 13-16 D 0.400 20/1 B 20/1 0.500 D FIRE ALARM BOOSTER 4 5 IFIRE SMOKE DAMPERS FLRS 17-19 D 0.300 20/1 C 20/1 0.500 D FIRE ALARM BOOSTER 6 7 FIRE SMOKE DAMPERS FLRS 16-18 D 0.300 20/1 A 20/1 0.500 D FIRE ALARM BOOSTER 8 9 FIRE SMOKE DAMPERS FLRS 13-15 D 0.300 2011 B 20/1 0.500 D FIRE ALARM BOOSTER 10 11 FIRE SMOKE DAMPERS FLRS 9-12 D 0.400 20/1 C 20/1 0.500 D FIRE ALARM BOOSTER 12 13 SPARE S - 20/1 A 2011 - S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 30/3 - - 0.000 - - D - - SPD (SURGE PROTECTIVE DEVICE) - - 26 27 SPARE S - 20/1 B 28 29 COR. EXH. LVERS (L-21,22,23,24,25) M 0.500 20/1 C 30 PHASE LOAD PHASE A= 1.70 KVA PHASE B= 1.70 KVA PHASE C= 2.20 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.50 5.10 0.50 5.60 KVA 15.54 AMP CALC. LOAD 0.50 5.10 0.13 5.73 KVA 15.89 AMP NOTES: PANEL AX1 8 LOCATION: ELECT / CATV RM 1800E SERVING: EM LOADS (CORRIDOR SMOKE EXHAUST) FED FROM: AX11 �L`%J 4801277 VOLT 250 AMP MAIN LUGS ONLY SCCR: 14,000 A 3 PHASE AFC: 9,426 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 SPARE S - 2011 A 15/3 - - 3.990 - - M - - PF-CD13 (3 HP) - - 2 3 SPARE S - 20/1 B 4 5 SPARE S - 20/1 C 6 7 SPARE S - 20/1 A 15/3 - - 3.990 - - M - - PF-CD14 (3 HP) - - 8 9 SPARE S - 20/1 B 10 11 1 SPARE S - 20/1 C 12 13 SPARE S - 20/1 A 15/3 - - 3.990 - - M - - PF-CD15 (3 HP) - - 14 15 SPARE S - 20/1 B 16 17 SPARE S - 20/1 C 18 19 SPARE S - ZO/1 A 15/3 - - 3.990 - - M - - PF-CD16 (3 HP) - - 20 21 SPARE S - 20/1 B 22 23 SPARE S - 20/1 C 24 25 SPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 20/1 B 20/1 - S SPARE 28 29 SPARE S - 2011 C 20/1 - S SPARE 30 31 SPARE S - 20/1 A 20/1 - S SPARE 32 33 SPARE S - 20/1 B 20/1 - S SPARE 34 35 SPARE S - 20/1 C 20/1 - S SPARE 36 37 SPD (SURGE PROTECTIVE DEVICE) - - D - - 0.000 - - 30/3 - - A 60/3 - - 2.400 - - P - - PNL ARX18 (VIA30KVAXFMR T-ARX18) - -. 38 39 B 40 41 C 42 PHASE LOAD PHASE A= 6.32 KVA PHASE B= 5.82 KVA PHASE C= 6.22 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL AX18 15.96 0.00 3.99 15.96 KVA 19.20 AMP PANEL ARX18 0.40 2.00 0.40 2.40 KVA 2.89 AMP CONN. LOAD 16.36 2.00 1 3.99 1 18.36 KVA 22.08 AMP CALC. LOAD 16.36 2.00 1.00 19.36 KVA 23.28 AMP NOTES: PANEL ARX18 LOCATION: ELECT / CATV RM 1800E SERVING. EM LOADS (CORRIDOR SMOKE EXHAUST)Lo4W6,,5 FED FROM: AX5 (VIA 30KVA XFMR T-ARX18) 2081120 VOLT 100 AMP BUS RATING SCCR: 10,000 A 3 PHASE 100 AMP MAIN BREAKER AFC: 1,754 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 SPARE S - 20/1 A 20/1 0.500 D FIRE ALARM BOOSTER 2 3 SPARE S - 20/1 B 20/1 0.500 D FIRE ALARM BOOSTER 4 5 SPARE S - 20/1 C 20/1 0.500 D FIRE ALARM BOOSTER 6 7 SPARE S - 20/1 A 20/1 0.500 D FIRE ALARM BOOSTER 8 9 SPARE S - 20/1 B 2011 - S SPARE 10 11 SPARE S - 20/1 C 20/1 - S SPARE 12 13 SPARE S - 20/1 A 20/1 - S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 30/3 - - 0.000 - - D - - SPD (SURGE PROTECTIVE DEVICE) - - 26 27 SPARE S - 20/1 B 28 29 COR. EXH. LOUVERS (L-26,27,28,29) M 0.400 20/1 C 30 PHASE LOAD PHASE A= 1.00 KVA PHASE B= 0.50 KVA PHASE C= 0.90 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.40 2.00 0.40 2.40 KVA 6.66 AMP CALC. LOAD 0.40 2.00 0.10 2.50 KVA 6.94 AMP NOTES: PANEL ARX19 LOCATION: ELECT / CAN RM 500E SERVING. EM LOADS (CORRIDOR SMOKE EXHAUST) FEDFROM: AX19 (VIA30KVAXFMR T ARX19) 208/120 VOLT 100 AMP BUS RATING SCCR: 10,000 A 3 PHASE 100 AMP MAIN BREAKER AFC: 1,852 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 SPARE S - 20/1 A 1 20/1 - S SPARE 2 3 SPARE S - 20/1 B 20/1 - S SPARE 4 5 SPARE S - 20/1 C 20/1 - S SPARE 6 7 SPARE S - 20/1 A 20/1 - S SPARE 8 9 SPARE S - 20/1 B 20/1 - S SPARE 10 11 SPARE S - 20/1 C 20/1 - S SPARE 12 13 SPARE S - 20/1 A 20/1 - S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 2011 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPD (SURGE PROTECTIVE DEVICE) - - D - - 0.000 - - 30/3 - - A 60/3 - - 2.890 - - P - - PANEL ELEV - - 26 27 B 28 29 C 30 PHASE LOAD PHASE A= 1.01 KVA PHASE B= 1.48 KVA PHASE C= 0.40 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL ARX19 0.00 0.00 KVA 0.00 AMP PANEL ELEV 1.81 1.08 0.00 2.89 KVA 8.02 AMP CONN. LOAD 1.81 1.08 0.00 1 2.89 KVA 8.02 AMP CALC. LOAD 2.26 1.08 0.00 3.34 KVA 9.28 AMP NOTES: PANEL AX7 LOCATION: ELECT / CATV RM 700E SERVING: EM LOADS (CORRIDOR SMOKE EXHAUST) FED FROM: AX5 Ft`Ir� TT-+kU 480/277 VOLT 250 AMP MAIN LUGS ONLY SCCR: 18,000 A 3 PHASE AFC: 15,581 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 PF-CD4 - - M - - 9,145 - - 20/3 - - A 20/1 3.448 L LTG- EGRESS (FLOORS 1-8) 2 3 B 20/1 2.564 L LTG - EGRESS (FLOORS 1-8) 4 5 C 20/1 0.400 L LTG - AOR 6 7 PF-CD5 - - M - - 9.145 - - 20/3 - - A 20/1 0.400 L LTG - AOR 8 9 B 20/1 - S SPARE 10 11 C 20/1 - S SPARE 12 13 PF-CD6 - - M - - 9.145 - - 20/3 - - A 20/1 - S SPARE 14 15 B 20/1 - S SPARE 16 17 C 20/1 - S SPARE 18 19 PF-CD7 - - M - - 9.145 - - 20/3 - - A 20/1 - S SPARE 20 21 B 20/1 - S SPARE 22 23 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 20/1 B 20/1 - S SPARE 28 29 SPARE S - 20/1 C 20/1 - S SPARE 30 31 SPARE S - 20/1 A 20/1 - S SPARE 32 33 SPARE S - 20/1 B 2011 - S SPARE 34 35 SPARE S - 20/1 C 20/1 - S SPARE 36 37 SPD (SURGE PROTECTIVE DEVICE) - - D - - 0.000 - - 30/3 - - A 60/3 - 3.200 - - P - - PANEL ARX7 (VIA30KVAXFMR T-ARX7) - - 38 39 B 40 41 C �42 PHASE LOAD PHASE A= 41.01 KVA PHASE B= 35.45 KVA PHASE C= 37.08 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL AX7 6.81 36.58 0.00 9.15 43.39 KVA 52.19 AMP PANEL AX11 12.72 47.12 7.10 9.15 66.94 KVA 80.52 AMP PANEL ARX7 0.40 2.80 0.40 3.20 KVA 3.85 AMP CONN. LOAD 19.53 84.10 9.90 9.15 113.53 KVA 136.56 AMP CALC. LOAD 24.42 84.10 9.90 2.29 120.70 KVA 145.18 AMP REQUIRED FEED-THRU LUGS AX I I OPTIONS: NOTES: PANEL ARX7 LOCATION: ELECT/ CATVRM 700E SERVING: EM LOADS (CORRIDOR SMOKE EXHAUST) FED FROM: AX5 (VIA 30KVA XFMR T-ARX7) 208/120 VOLT 100 AMP BUS RATING SCCR: 10,000A 3 PHASE 100 AMP MAIN BREAKER AFC: 1,813 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 FIRE SMOKE DAMPERS FLRS 2-4 D 0.300 20/1 A 1 20/1 0.500 D FIRE ALARM BOOSTER 2 3 FIRE SMOKE DAMPERS FLRS 5-8 D 0.400 20/1 B 1 20/1 0.500 D FIRE ALARM BOOSTER 4 5 FIRE SMOKE DAMPERS FLRS 3-5 D 0.300 20/1 1 C 20/1 0.500 D FIRE ALARM BOOSTER 6 7 FIRE SMOKE DAMPERS FLRS 6-8 D 0.300 20/1 A 1 20/1 - S SPARE 8 9 SPARE S - 20/1 B 1 20/1 - S SPARE 10 11 SPARE S - 20/1 C 20/1 - S SPARE 12 13 SPARE S - 20/1 A 20/1 - S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 2011 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 20/1 B 1 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 30/3 - - 0.000 - - D - - SPD (SURGE PROTECTIVE DEVICE) - - 26 27 SPARE S - 20/1 B 28 29 COR. EXH. LOUVERS (L-17,18,19,20) M 0.400 20/1 C r3O PHASE LOAD PHASE A= 1.10 KVA PHASE B= 0.90 KVA PHASE C= 1.20 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 0.40 2.80 0.40 3.20 KVA 8.88 AMP CALC. LOAD 0.40 2.80 0.10 3.30 KVA 9.16 AMP NOTES: PANEL AX 1. t LOCATION: ELECT/ CAN RM 1100E SERVING: EM LOADS (CORRIDOR SMOKE EXHAUST) FEDFROM: AX7 )':�,' 480/277 VOLT 250 AMP MAIN LUGS ONLY SCCR: 18,000 A 3 PHASE AFC: 13,413 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LTG -EGRESS (FLOORS 12-17) L 1.399 20/1 A 20/3 - - 9.145 - - M - - PF-CD8 (7.5 HP) - - 2 3 LTG -EGRESS (FLOORS 12-17) L 0.810 20/1 B 4 5 LTG -EGRESS (FLOORS 9-19) L 3.401 20/1 C 6 7 LTG -EGRESS (FLOORS 9-9) L 3.383 20/1 A 20/3 - - 9.145 - - M - - PF-CD9 (7.5 HP) - - 8 9 LTG -ELEVATOR PIT 01 L 0.488 20/1 B 10 11 LTG -ELEVATOR PIT 02 L 0.488 20/1 C 12 13 LTG -ELEVATOR PIT03 L 0.488 20/1 A 15/3 - - 3.990 - - M - - PF-CD10 (3 HP) - - 14 15 LTG -ELEVATOR PIT 04 L 0.488 20/1 B 16 17 LTG -ELEVATOR PIT 05 L 0.488 20/1 C 18 19 LTG -ELEVATOR PIT 06 L 0.488 20/1 A 15/3 - - 3.990 - - M - - PF-CD11 (3 HP) - - 20 21 LTG - AOR L 0.400 20/1 B 22 23 LTG - AOR L 0.400 20/1 C 24 25 SPARE S - 20/1 A 15/3 - - 3.990 - - M - - PF-CD12 (3 HP) - - 26 27 SPARE S - 20/1 B 28 29 SPARE S - 20/1 C 30 31 SPARE S - 20/1 A 20/1 - S SPARE 32 33 SPARE S - 20/1 B 20/1 - S SPARE 34 35 SPARE S - 20/1 C 20/1 - S SPARE 36 37 SPD (SURGE PROTECTIVE DEVICE) - - D - - 0.000 - 30/3 - - A 60/3 - - 5.600 - - P - - PNL ARX11 (VIA30KVAXFMR T-ARX11) - - 38 39 B 40 41 C �42 PHASE LOAD PHASE A= 23.86 KVA PHASE B= 19.79 KVA PHASE C= 23.28 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL AX11 12.72 30.26 0.00 9.15 42.98 KVA 51.70 AMP PANEL AX18 16.36 2.00 3.99 18.36 KVA 22.08 AMP PANEL ARX11 0.50 5.10 0.50 5.60 KVA 6.74 AMP CONN. LOAD 12.72 47.12 7.10 9.15 66.94 KVA 80.52 AMP CALC. LOAD 15.90 47.12 7.10 2.29 72.41 KVA 87.09 AMP REQUIRED FEED-THRU LUGS ->Ag t g OPTIONS: NOTES: REVIEWED FOH COMPLIANCE WITH RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER U EL 0 3 2015 I City of-Tuicwil� RHILDING PANEL SCHEDULE INDEX PANEL NAME PANEL NAME PANEL NAME AX19 ARX11 AX7 ELEV AX18 ARX7 ELEV-1,2,3 ARX18 AX11 ELEV-4,5,6 ARX19 1 - ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY. CHL APPROVED BY: DRAWN BY: JAB .AN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: Ow Y z a� O � Q W J F_ pY V Q I- z N N �T 1 N 1LTANT ITRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 826-4446 SHEET TITLE AND NUMBER ELECTRICAL PANEL SCHEDULES E8.04 m 3 (N W J 0 W U J W acq N a. o :aT W to . ,s v� o PANEL HL1 LOCATION: ELEC RM 1 ST FLR SERVING: HOTEL LIGHTING LOADS (NEC 702) FEDFROM: HDB (VAA200AATS-2) 480/277 VOLT 200 AMP MAIN LUGS ONLY SCCR: 50,000 A 3 PHASE AFC: 41,084 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LTG- HOTEL LOBBY/CORRIDORS L 1.740 20/1 A 20/1 2.424 L LTG - EAST SITE (NOTE 1) 2 3 LTG- FITNESS, RESTRMS, LAUNDRY L 2.394 20/1 B 20/1 - S SPARE 4 5 LTG - DINING AREA L 2.763 20/1 C 20/1 3.000 L SIGN LIGHTING (NOTE 1) 6 7 LTG - HOTEL ELEV L 0.366 20/1 A 20/1 - S SPARE 8 9 LTG - HOTEL EXTERIOR (NOTE 1) L 0.750 20/1 B 20/1 0.624 L LTG -16TH FLOOR EXTER. (NOTE 1) 10 11 LTG -HOTEL EXT. CANOPY (NOTE 1) L 0.540 20/1 C 20/1 0.884 L LTG - 16TH FLOOR EXTER. (NOTE 1) 12 13 LTG- KITCHEN L 0.801 20/1 A 20/1 - S SPARE 14 15 ILTG - POOL AREA (NOTE 1) L 0.768 2011 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 WALK-IN COOLER (5 HP) (HOTEL KITCHEN) - D - - 6.500 - - 20/3 - - A 20/1 - S SPARE 26 27 B 20/1 - S SPARE 28 29 C 20/1 - S SPARE 30 31 WALK-IN FREEZER (5 HP) (HOTEL KITCHEN) - D - - 6.500 - - 20/3 - - A 20/1 - S SPARE 32 33 B 20/1 - S SPARE 34 35 C 20/1 - S SPARE 36 37 HOOD (HOTEL KITCHEN) (7.5 HP) (NOTE 1) - M - - 9.145 - - 20/3 - - A 100/3 - - 46.600 - - P - - PANEL HR1 (MA75KVAXFMR T-HR1) - - 38 39 B 40 41 C 42 PHASE LOAD PHASE A= 27.47 KVA PHASE B= 26.70 KVA PHASE C= 31.63 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HL1 17.05 9.15 13.00 9.15 39.20 KVA 47.15 AMP PANEL HR1 17.82 3.17 1.15 24.46 2.11 46.60 KVA 56.05 AMP CONN. LOAD 17.05 17.82 12.31 1.15 37.46 1 9.15 85.80 KVA 103.20 AMP CALC. LOAD 21.32 13.91 12.31 1.15 37.46 2.29 88.44 KVA 106.38 AMP NOTES: 1.) ROUTE VIA LIGHTING CONTROL PANEL'LCP-H'. PANEL HR1 LOCATION: ELEC RM 1 ST FLR SERVING: HOTEL RECEPTACLE LOADS FEDFROM: HL1 (VIA75KVAXFMRT-HR1) 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 225 AMP MAIN BREAKER AFC: 5,922 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 EFA/9 M 0.528 15/1 A 20/1 1.080 D GAS -FIRED BOILER (B-1) 2 3 RCPT - RM 134 R 0.900 20/1 B 20/1 1.080 D GAS -FIRED BOILER (B-2) 4 5 RCPT - RM 134 R 0.900 20/1 C 25/1 2.112 M EF-V11, EF-V12, EF-V13, EF-VI4 6 7 RCPT- RM 134 R 0.720 20/1 A 20/1 0.720 R RCPT- DINING 8 9 RCPT- RM 117,118 R 0.900 20/1 B 20/1 - S SPARE 10 11 RCPT- RM 117,118 R 0.900 20/1 C 20/1 - S SPARE 12 13 IRCPT - RM 117,118 R 0.720 20/1 A 20/1 0.720 R RCPT - DINING / EXTERIOR 14 15 RCPT - FRONT DESK R 0.360 2011 B 20/1 0.900 R RCPT - DINING / EXTERIOR 16 17 RCPT- FRONT DESK R 0.360 20/1 C 15/1 1.152 WH DWH-5 (WTR HTR) (LEVEL 1) 18 19 RCPT- FRONT DESK R 0.360 20/1 A 15/1 . 0.528 M RCP-8 (RECIRC PUMP) (LEVEL 1) 20 21 RCPT- LOBBY, 133,122 R 0.720 20/1 B 20/1 0.720 R RCPT- FLOORBOX HOTEL LOBBY 22 23 RCPT- LOBBY, 120, 121, 133 R 0.720 20/1 C 20/1 0.720 R RCPT- FLOOR BOX HOTEL LOBBY 24 25 RCPT- LOBBY, 121,128 R 0.900 20/1 A 20/1 0.720 R RCPT- FLOORBOX HOTEL DINING 26 27 RCPT- RM 126,125 R 0.720 2011 B 20/1 0.720 R RCPT- FLOORBOX HOTEL DINING 28 29 RCPT- RM 127,127, EXTERIOR R 0.540 20/1 C 20/1 1.800 D TYPE I RANGE HOOD 30 31 RCPT- RM 126, 127, ST-103 R 0.540 20/1 A 20/1 0.360 R RCPT. RM 134 32 33 RCPT- ELEV#1, 2, 3 PIT R 0.540 20/1 B 20/1 0.360 R RCPT. RM 134 34 35 SECURITYGATE D 0.500 20/1 C 20/1 0.360 R RCPT. RM 134 36 37 SPARE S - 20/1 A 20/1 0.360 R RCPT. RM 134 38 39 SPARE S - 20/1 B 20/1 0.360 R RCPT. RM 134 40 41 RCPT - DATA RACKS (LEVELS 2 & 3) D 0.500 20/1 C 20/1 - S SPARE 42 43 RCPT- DATA RACKS (LEVELS 4 & 5) D 0.500 20/1 A 20/1 - S SPARE 44 45 RCPT- DATA RACKS (LEVELS 6 & 7) D 0.500 20/1 B 20/1 - S SPARE 46 47 RCPT - DATA RACKS (LEVELS 8 & 9) D 0.500 20/1 C 20/1 - S SPARE 48 49 RCPT-DATA RACKS (LEVELS 10 & 11) D 0.500 20/1 A 20/1 - S SPARE 50 51 RCPT- DATARACKS (LEVELS 2 & 3) D 0.500 20/1 B 20/1 - S SPARE 52 53 RCPT- DATARACKS (LEVELS 4 & 5) D 0.500 20/1 C 20/1 - S SPARE 54 55 RCPT - DATA RACKS (LEVELS 6 & 7) D 0.500 20/1 A 60/3 - - 15.000 - - P - - PANEL HC1 (COFFEE SHOP) - - 56 57 RCPT- DATA RACKS (LEVELS 8 & 9) D 0.500 20/1 B 58 59 RCPT- DATARACKS (LEVELS 10 & 11) D 0.500 20/1 C 60 PHASE LOAD PHASE A= 14.76 KVA PHASE B= 14.78 KVA PHASE C= 17.06 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL HR1 17.82 3.17 1.15 9.46 2.11 31.60 KVA 87.71 AMP PANEL HCl 15.00 15.00 KVA 41.64 AMP CONN. LOAD 17.82 3.17 1.15 24.46 2.11 46.60 KVA 129.36 AMP CALC. LOAD 13.91 3.17 1.15 24.46 0.53 43.22 KVA 1 119.96 AMP NOTES: PANEL HC1 LOCATION: ELEC RM 1ST FLR -COFFEE SHOP SERVING. HOTEL COFFEE SHOP FEDFROM: HR1 208/120 VOLT 100 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 1,875 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 FUTURE COFFEE SHOP - - D - - 15.000 - - /3 - - A 1 20/1 0.305 T LTG- RM 116A 2 3 B 20/1 - S SPARE 4 5 Cl20/1 - S SPARE 6 7 SPARE S - 20/1 A 20/1 - S SPARE 8 9 SPARE S - 20/1 B 20/1 - S SPARE 10 11 SPARE S - 20/1 C 20/1 - S SPARE 12 13 SPARE S - 20/1 A 20/1 - S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 20/1 B 20/1 - S SPARE 28 29 SPARE S - 20/1 C 20/1 - S SPARE 30 PHASE LOAD PHASE A= 5.00 KVA PHASE B= 5.00 KVA PHASE C= 5.00 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 15.00 15.00 KVA 41.64 AMP CALC. LOAD 15.00 15.00 KVA 41.64 AMP NOTES: " = GFCI CIRCUIT BREAKER. PANEL HY1 LOCATION: ELEC RM 1ST FLR - LAUNDRY RM SERVING: HOTEL LAUNDRY EQUIPMENT FEDFROM: HDB (VAA45KVAXFMR T-HY1) 208/120 VOLT 150 AMP BUS RATING SCCR: 10,000 A 3 PHASE 150 AMP MAIN BREAKER AFC: 3,048 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 RCPT-LAUNDRY ROOM R 0.360 `20/1 A 20/3 - - 5.760 - - A - - WASHER (LAUNDRY ROOM 125) - 2 3 RCPT- LAUNDRY ROOM R 0.540 `20/1 B 4 5 SPARE S - 20/1 C 6 7 SPARE S - 20/1 A 20/3 - - 5.760 - - A - - WASHER (LAUNDRY ROOM 125) - 8 9 SPARE S - 2011 B 10 11 SPARE S - 20/1 C 12 13 SPARE S - 20/1 A 20/3 - - 5.760 - - A - WASHER (LAUNDRY ROOM 125) - 14 15 SPARE S - 20/1 B 16 17 SPARE S - 20/1 C 18 19 SPARE S - 20/1 A 20/3 - - 2.772 - - A - - DRYER (LAU N DRY ROOM 125) - 20 21 SPARE S - 20/1 B 22 23 SPARE S - 20/1 C 24 25 SPARE S - 20/1 A 20/3 - - 2.772 - - A - - DRYER (LAUNDRY ROOM 125) - 26 27 SPARE S - 20/1 B 28 29 SPARE S - 20/1 C 30 31 SPARE S - 20/1 A 20/3 - - 2.772 - - A - - DRYER (LAUNDRY ROOM 125) - 32 33 SPARE S - 20/1 B 34 35 SPARE S - 20/1 C 36 37 SPARE S - 20/1 A 20/3 - - - - - S - - SPARE - - - 38 39 SPARE S - 20/1 B [22 41 LAUNDRY CHUTE INTERLOCK SYS. D 0.500 2011 C PHASE LOAD PHASE A= 8.89 KVA PHASE B= 9.07 KVA PHASE C= 9.03 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.90 0.50 25.60 27.00 KVA 74.93 AMP CALC. LOAD 0.90 0.50 25.60 27.00 KVA 74.93 AMP NOTES: = GFCI CIRCUIT BREAKER. PANEL HK1 LOCATION: KITCHEN SERVING: HOTEL KITCHEN LOADS FEDFROM: HDB 480/277 VOLT 250 AMP MAIN LUGS ONLY SCCR: 25,000 A 3 PHASE AFC: 17,674 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA AIP ' PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 SPARE S - 20/1 A 1 1 20/1 1 - S SPARE 2 3 SPARE S - 20/1 B 1 1 20/1 - S SPARE 4 5 SPARE S - 20/1 C 20/1 - S SPARE 6 7 SPARE S - 20/1 A 1 1 20/1 - S SPARE 8 9 SPARE S - 20/1 B 1 20/1 - S SPARE 10 11 SPARE S - 20/1 C 2011 - S SPARE 12 13 SPARE S - 20/1 A 20/1 - S SPARE 14 15 SPARE S - 20/1 B 20/1 - S SPARE 16 17 SPARE S - 20/1 C 20/1 - S SPARE 18 19 SPARE S - 20/1 A 20/1 - S SPARE 20 21 SPARE S - 2011 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 20/1 B 20/1 - S SPARE 28 29 SPARE S - 20/1 C 20/1 - S SPARE 30 31 SPARE S - 20/1 A 20/1 - S SPARE 32 33 SPARE S - 20/1 B 20/1 - S SPARE 34 35 SPARE S - 20/1 1 C 20/1 - S SPARE 36 37 SPARE S - 20/1 A 100/3 - - 64.550 - - P - - PANEL HKR (VIA 45 KVAXFMR T-HKR) - - 38 39 SPARE S - 20/1 B 40 41 SPARE S - 20/1 C �42 PHASE LOAD PHASE A= 19.89 KVA PHASE B= 22.51 KVA PHASE C= 22.16 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HK1 KVA AMP PANEL HKR 0.54 5.00 59.01 64.55 KVA 77.64 AMP CONN LOAD 10.54 5.00 1 59.01 64.55 KVA 77.64 AMP CALC. LOAD 0.54 5.00 38.36 43.90 KVA 52.80 AMP NOTES: PANEL HKR LOCATION: KITCHEN SERVING: HOTEL KITCHEN LOADS FED FROM: HK1 (VIA45 KVAXFMR T-HKR) 2081120 VOLT 150 AMP BUS RATING SCCR: 10,000 A 3 PHASE 150 AMP MAIN BREAKER AFC: 3,307 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 CONVECTION OVEN K 1.200 20/1 Al20/2 - 2.250 - K - HOT WELUFOOD TABLE - 2 3 SPACE (SHUNTTRIP) S - - B I 4 5 6 RANGE BURNER K 0.500 20/1 C 20/1 1.500 K HEAT LAMP 6 7 SPACE (SHUNTTRIP) S - - A 20/1 1.200 K SANDWICH PREP 8 9 GAS WOK RANGE K 0.500 20/1 B 20/2 - 3.000 - K - WALK IN COOLER - 1 11 SPACE (SHUNTTRIP) S - - C 12 13 FAT FRYER K 1.500 2011 A 20/2 - 3.000 - K - EVAP COIL - 14 15 SPACE (SHUNTTRIP) S - - B 16 17 FAT FRYER K 1.500 20/1 C 20/2 - 3.000 - K - WALK IN COOKER - 18 19 SPACE (SHUNTTRIP) S - - A 20 21 GAS RADIENT BOILER K 0.500 20/1 IBI 1 20/2 - 3.000 - K - EVAP COIL - 22 23 SPACE (SHUNTTRIP) S - - C 24 25 IGAS GRIDDLE K 0.500 20/1 A 20/1 1.500 K HOT HOLDING 26 27 SPACE (SHUNTTRIP) S - - B 20/1 1.800 K RICE COOKER 28 29 SALAMANDER BROILER K 0.500 20/1 C 20/1 1.800 K MIXER 30 31 SPACE (SHUNTTRIP) S - - A 20/1 1.800 K SLICER 32 33 PREP FIDGE K 1.200 20/1 B 20/1 1.800 K DISHWASHER 34 35 MICROWAVE K 1.000, 20/1 C 20/1 1.440 K FREEZER 36 37 TOASTER K 1.500 20/1 A 20/1 1.440 K COOLER 38 39 HOT WATER HEATER - WH - 5.000 - 30/2 - B 20/1 1.800 K ICE MACHINE 40 41 C 20/1 0.500 K STOCK POT RANGE 42 PHASE LOAD PHASE A= 19.89 KVA PHASE B= 22.51 KVA PHASE C= 22.16 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HKR 5.00 41.23 46.23 KVA 128.32 AMP SEC 11 0.54 17.78 18.32 KVA 50.85 AMP CONN. LOAD 0.54 5.00 59.01 64.55 KVA 179.17 AMP CALC. LOAD 0.54 5.00 38.36 1 43.90 KVA 121.84 AMP PANEL SEC 2 LOCATION: KITCHEN SERVING: 3PHASE LOADS FED FROM: SECTION 1 208/120 VOLT 150 AMP MAIN LUGS ONLY 10,000 A 3 PHASE 3,307 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 43 TEAURN - K - 3.000 - 20/2 - A 20/1 0.500 K P.O.S. 44 45 B 20/1 1.800 K COFFEE BREWER 46 47 SPARE S - 20/1 C 20/1 1.200 K FRIDGE 48 49 ISPARE S - 20/1 A 20/1 0.500 K P.O.S. 50 51 SPARE S - 20/1 B 20/1 1.800 K COFFEE BREWER 52 53 SPARE S - 20/1 C 20/1 1.440 K BAR COOLER 54 55 SPARE S - 20/1 A 20/1 1.440 K BAR COOLER 56 57 SPARE S - 20/1 B 20/1 0.500 K P.O.S. 58 59 SPARE S - 20/1 C 20/1 1.800 K GLASS WASHER 60 61 SPARE S - 20/1 A 20/1 1.000 K BLENDER 62 63 SPARE S - 20/1 B 20/1 1.000 K BLENDEER 64 65 SPARE S - 2011 C 20/1 1.800 K ICE MAKER 66 67 SPARE S - 20/1 A 20/1 0.180 R RCPT RM 123 68 69 SPARE S - 20/1 B 20/1 0.180 R RCPT RM 123 70 71 SPARE S - 2011 C 20/1 0.180 R RCPT RM 123 72 73 SPARE S - 20/1 A 20/1 - S SPARE 74 75 SPARE S - 20/1 B 20/1 - S SPARE 76 77 SPARE S - 20/1 C 20/1 - S SPARE 78 79 SPARE S - 20/1 A 20/1 - S SPARE 80 81 SPARE S - 20/1 B 20/1 - S SPARE 82 83 SPARE S - 20/1 C 20/1 - S SPARE 84 PHASE LOAD PHASE A-= 5.12 KVA PHASE B= 6.78 KVA PHASE C= 6.42 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.54 17.78 111.32 KVA 50.85 AMP CALC. LOAD 0.54 11.56 1 12.10 KVA 33.58 AMP REQUIRED FEED-THRU LUGS OPTIONS: PANEL HDB LOCATION: ELEC RM 1 ST FLR SERVING: HOTEL LOADS FED FROM: MSB 480/277 VOLT 1600 AMP MAIN LUGS ONLY SCCR: 65,000 A 3 PHASE AFC: 44,555 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE AIP KVA TYPE LOAD DESCRIPTION CKT 1 PANEL HM1 - - P - - 105.564 - - 400/3 - - A 1200/3 - - 1003.467 - - P - - HOTEL BUS DUCT (BD-1) - - 2 3 B 4 5 C 6 7 PANEL HL1 (VIA200AATS-2) - - P - - 85.799 - - 200/3 - - A 150/3 - - 81.473 - - M - - ERV 1 (MECH UNIT) - - 8 9 B 10 11 C 12 13 PANEL HY1 (VIA 45KVA XFMR T-HY1) - - P - 26.996 - - 100/3 - - A 20013 - - 64.550 - - P - - PANEL HK1 - - 14 15 B 16 17 C 18 19 SPARE - - S - - - - - 200/3 - - A 400/3 - - - - - S - - SPARE - - 20 21 B 22 23 C 24 PHASE LOAD PHASE A= 468.84 KVA PHASE B= 451.46 KVA PHASE C= 447.54 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HDB 81.47 81.47 81.47 KVA 98.00 AMP PANEL HM1 103.38 2.19 28.25 105.56 KVA 126.97 AMP BUS DUCT BD-1 21.12 37.28 778.72 5.00 9.00 132.35 20.00 55.17 1,003.47 KVA 1,206.98 AMP PANEL HL1 17.05 17.82 12.31 1.15 37.46 9.15 85.80 KVA 103.20 AMP PANEL HK1 0.54 5.00 59.01 64.55 KVA 77.64 AMP PANEL HY1 0.90 0.50 25.60 27.00 KVA 32.47 AMP CONN. LOAD 38.18 56.54 975.88 7.19 15.15 132.35 57.96 25.60 59.01 81.47 1,367.85 KVA 1,645.27 AMP CALC. LOAD 47.72 33.27 975.88 7.19 15.15 51.70 57.96 25.60 38.36 20.37 1,2113.19 KVA 1,531.41 AMP NOTES: PANEL BD-1 LOCATION: VERTICAL BUS DUCT (HOTEL) SERVING: HOTEL LOADS FEDFROM: HDB 480/277 VOLT 1200 AMP MAIN LUGS ONLY SCCR: 65,000 A 3 PHASE AFC: 40,151 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 PANEL HP2 - - P - - 228.985 - - 400/3 - - A 100/3 - - 68.655 - - P - - PANEL HR2A(VIA 75 KVAXFMR T-2H) - - 2 3 B 4 5 C 6 HP4 P - 168.740 - 40013 - - A 400/3 - - 175.598 - - P - - PANEL HP6 - - 8- NPANEL B 10- C 12 13 PANEL HP8 - - P - - 173.004 - - 400/3 - - A 400/3 - - 188.485 - - P - - PANEL HP10 - - 14 15 B 16 17 C 18 19 SPACE - - S - - - - - /3 - - A /3 - - - - - S - - SPACE - - 20 21 B 22 23 C 24 PHASE LOAD PHASE A= 349.65 KVA PHASE B= 333.34 KVA PHASE C= 320.47 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL BD-1 KVA AMP PANEL HP2 21.12 207.86 55.17 228.99 KVA 275.43 AMP PANEL HR2A 33.68 5.00 5.00 12.98 12.00 5.00 68.66 KVA 82.58 AMP PANEL HP4 0.90 139.40 26.44 2.00 3.40 168.74 KVA 202.96 AMP PANEL HP6 0.90 140.58 4.50 27.62 2.00 3.40 175.60 KVA 211.21 AMP PANEL HP8 0.90 142.80 27.30 2.00 1 3.40 173.00 KVA 208.09 AMP PANEL HP10 0.90 143.07 4.50 38.01 2.00 3.40 188.49 KVA 226.71 AMP CONN. LOAD 21.12 37.28 778.72 5.00 9.00 132.35 20.00 55.17 1,003.47 KVA 1,206.98 AMP CALC. LOAD 26.40 23.64 778.72 15.00 9.00 51.70 20.00 13.79 928.26 KVA 1,116.52 AMP NOTES: PANEL SCHEDULE IS SHOWN FOR VERTICAL BUS DUCT, OVERCURRENT DEVICES SHWON ARE FUSE SIZES REQUIRED AT FUSIBLE DISCONNECTS CONNECTED TO BUS DUCT. REFER TO ONE -LINE DIAGRAM. PANEL HMI LOCATION: ELEC RM 1 ST FLR SERVING: HOTEL MErHANICAL LOADS FED FROM: HDB 480/277 VOLT 400 AMP MAIN LUGS ONLY SCCR: 50,000 A 3 PHASE AFC: 42,849 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 P-CDS-1 - - M - - 28.254 - - 60/3 - - A 15/1 1.551 M WSHP-1-3H 2 3 B 1511 - S SPARE 4 5 C 15/3 - - 4.737 - - M - - WSHP-1-6H - - 6 7 P-CDS-2 - - M - - 25.254 - - 60/3 - - A 8 9 B 10 11 C 20/3 - - 12.387 - - M - - WSHP-1-2H - - 12 13 SPARE S - 20/1 A 14 15 SPARE S - 20/1 B 16 17 SPARE S - 20/1 C 15/3 - - 5.817 - - M - - WSHP-1-lH - - 18 19 SPARE S - 20/1 A 20 21 SPARE S - 20/1 B 22 23 SPARE S - 20/1 C 15/3 - - 5.817 - - M - - WSHP-1-9H - - 24 25 SPARE S - 2011 A 26 27 SPARE S - 20/1 B 28 29 SPARE S - 20/1 C 15/1 2.742 M WSHP-1-7H 30 31 SPARE S - 20/1 A 15/1 1.551 M WSHP-1-8H 32 33 SPARE S - 20/1 B 15/1 - S SPARE 34 35 SPARE S - 20/1 C 15/1 - S SPARE 36 37 SPARE S - 20/1 A 15/3 - - 9.473 - - M - - WSHP-1-5H - 38 39 SPARE S - 20/1 B 40 41 SPARE S - 20/1 C 42 43 SPARE S - 20/1 A 15/3 - - 4.737 - - M - - WSHP-I-4H - - 44 45 SPARE S - 20/1 B 46 47 SPARE S - 20/1 C 48 49 SPARE S - 20/1 A 15/1 0.528 M EF-V1 50 51 SPARE S - 20/1 B 15/1 0.528 M EF-V2 52 53 SPARE S - 20/1 C 20/1 2.188 H UH-1 54 55 SPARE S - 20/1 A 1 20/1 - S SPARE 56 57 SPARE S - 20/1 B 20/1 - S SPARE 58 59 SPARE S - 20/1-- W 20/1 - S SPARE 60 PHASE LOAD PHASE A= 35.79 KVA PHASE B= 32.69 KVA PHASE C= 37.09 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 103.38 2.19 2§.25' Vl� i F 1 126.97 AMP CALC. LOAD 103.38 2.19 4.S •47 AMP NOTES: I RECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENTER City of Tukwilc ml ftl f1tl►ti� iilt/�C`IE 3i, PANEL .. 'INDEX PANEL NAME PANEL NAME PANEL NAME HL1 HY1 HDB HR1 HK1 BD-1 HC1 HKR HM1 ISSUE 0 Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB 'LAN PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: O w F Y fY Q z EL W Q W J F_ pY V Q 1- z CM N T� N ��1 VJ ;ULTANT STRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826.4446 SHEET TITLE AND NUMBER ELECTRICAL PANEL SCHEDULES E8.05 PANEL HR413 LOCATION: ELEC RM 4TH FLR SERVING: HOTEL LOADS FED FROM: HR4A 208/120 VOLT 225 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 5,563 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 GUEST ROOM 505 HM 0.225 20/1 A 20/1 0.220 HM GUEST ROOM 502 2 3 GUEST ROOM 505 HM 0.225 20/1 B 20/1 0.220 HM GUEST ROOM 502 4 5 GUESTROOM505 HM 0.225 20/1 C 20/1 0.220 HM GUEST ROOM502 6 7 GUEST ROOM 507 HM 0.221 20/1 A 20/1 0.220 HM GUEST ROOM 504 8 9 GUEST ROOM 507 HM 0.221 20/1 B 20/1 0.220 HM GUEST ROOM 504 10 11 GUEST ROOM 507 HM 0.221 2011 C 20/1 0.220 HM GUEST ROOM 504 12 13 GUEST ROOM 509 HM 0.223 20/1 A 2011 0.202 HM GUEST ROOM 506 14 15 GUEST ROOM 509 HM 0.223 20/1 B 20/1 0.202 HM GUEST ROOM 506 16 17 GUESTROOM509 HM 0.223 20/1 C 2011 0.202 HM GUESTROOM506 18 19 GUEST ROOM 511 HM 0.223 20/1 A 20/1 0.202 HM GUEST ROOM 508 20 21 GUEST ROOM 511 HM 0.223 20/1 B 20/1 0.202 HM GUEST ROOM 508 22 23 GUEST ROOM 511 HM 0.223 2011 C 20/1 0.202 HM GUEST ROOM 508 24 25 GUEST ROOM 513 HM 0.221 20/1 A 20/1 0.200 HM GUESTROOM510 26 27 GUESTROOM513 HM 0.221 20/1 B 2011 0.200 HM GUESTROOM510 28 29 GUESTROOM513 HM 0.221 2011 C 20/1 0.200 HM GUESTROOM510 30 31 GUEST ROOM 515 HM 0.221 20/1 A 20/1 0.200 HM GUEST ROOM 512 32 33 GUESTROOM515 HM 0.221 20/1 B 20/1 0.200 HM GUESTROOM512 34 35 GUEST ROOM 515 HM 0.221 20/1 C 20/1 0.200 HM GUEST ROOM 512 36 37 GUEST ROOM 517 HM 0.223 20/1 A 20/1 0.202 HM GUESTROOM514 38 39 GUEST ROOM 517 HM 0.223 20/1 B 20/1 0.202 HM GUEST ROOM 514 40 41 GUEST ROOM 517 HM 0.223 20/1 C 20/1 0.202 HM GUEST ROOM 514 42 43 GUEST ROOM 519 HM 0.223 20/1 A 20/1 0.222 HM GUEST ROOM 516 44 45 GUEST ROOM 519 HM 0.223 20/1 B 2011 0.222 HM GUEST ROOM 516 46 47 GUEST ROOM 519 HM 0.223 20/1 C 20/1 0.222 HM GUEST ROOM 516 48 49 GUEST ROOM 521 HM 0.202 20/1 A 20/1 0.257 HM GUEST ROOM 518 50 51 GUEST ROOM 521 HM 0.202 20/1 B 20/1 0.257 HM GUEST ROOM 518 52 53 GUEST ROOM 521 HM 0.202 20/1 C 2011 0.257 HM GUEST ROOM 518 54 55 GUEST ROOM 523 HM 0.191 20/1 A 20/1 - S SPARE 56 57 GUESTROOM523 HM 0.191 20/1 B 20/1 - S SPARE 58 59 GUESTROOM523 HM 0.191 20/1 C 20/1 - S SPARE 60 PHASE LOAD PHASE A= 6.42 KVA PHASE B= 5.79 KVA PHASE C= 5.15 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HR413 12.29 12.29 KVA 34.12 AMP PANEL HR4C 0.72 2.34 2.00 5.06 KVA 14.06 AMP CONN. LOAD 1 0.72 14.64 2.00 17.36 KVA 48.18 AMP CALC. LOAD 0.72 7.32 1 2.00 10.04 KVA 27.87 AMP REQUIRED FEED-THRU LUGS OPTIONS: PANEL HR4C LOCATION: ELEC RM 4TH FLR SERVING: HOTEL LOADS FED FROM: HR413 2081120 VOLT 225 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 5,501 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 RCPT- HOUSEKEEPING 4TH FLR R 0.360 20/1 A 20/1 0.274 HM GUEST ROOM 401 2 3 RCPT- ICE MAKER 4TH FLR D 1.000 *2011 B 20/1 0.274 HM GUEST ROOM 401 4 5 RCPT - HOUSEKEEPING 5TH FLR R 0.360 20/1 C 20/1 0.274 HM GUESTROOM401 6 7 RCPT- ICE MAKER 5TH FLR D 1.000 *20/1 A 2011 0.274 HM GUEST ROOM401 8 9 SPARE S - 20/1 B 20/1 0.200 HM GUEST ROOM 503 10 11 SPARE S - 20/1 C 20/1 0.200 HM GUEST ROOM 503 12 13 SPARE S - 20/1 A 20/1 0.200 HM GUEST ROOM 503 14 15 SPARE S - 20/1 B 20/1 0.216 HM GUESTROOM501 16 17 SPARE S - 20/1 C 20/1 0.216 HM GUESTROOM501 18 19 SPARE S - 20/1 A 2011 0.216 HM GUESTROOM501 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 2011 - S SPARE 24 25 SPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 20/1 B 20/1 - S SPARE 28 29 SPARE S - 20/1 C 20/1 - S SPARE 30 31 SPARE S - 20/1 A 20/1 - S SPARE 32 33 SPARE S - 20/1 B 20/1 - S SPARE 34 35 SPARE S - 20/1 C 20/1 - S SPARE 36 37 SPARE S - 20/1 A 20/1 - S SPARE 38 39 SPARE S - 20/1 B 20/1 - S SPARE 40 41 SPARE S - 20/1 C 20/1 - S SPARE 42 43 SPARE S - 20/1 A 20/1 - S SPARE 44 45 SPARE S - 20/1 B 20/1 - S SPARE 46 47 SPARE S - 20/1 C 20/1 - S SPARE 48 49 SPARE S - 20/1 A 20/1 - S SPARE 50 51 SPARE S - 20/1 B 20/1 - S SPARE 52 53 SPARE S - 20/1 C 2011 - S SPARE 54 55 SPARE S - 20/1 A 20/1 - S SPARE 56 57 SPARE S - 20/1 B 20/1 - S SPARE 58 59 SPARE S - 2011 C =/l - S SPARE 60 PHASE LOAD PHASE A= 2.32 KVA PHASE B= 1.69 KVA PHASE C= 1.05 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.72 2.34 2.00 5.06 KVA 14.06 AMP CALC. LOAD 0.72 1.17 2.00 3.89 KVA 10.80 AMP NOTES: * = GFCI CIRCUIT BREAKER. PANEL HP6 LOCATION: ELEC RM 6TH FLR SERVING: HOTEL LOADS FED FROM: BUS DUCT BD-1 480/277 VOLT 400 AMP MAIN LUGS ONLY SCCR: 50,000 A 3 PHASE AFC: 32,789 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A1P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 MECH - RM 601 M 3.400 20/1 A 2011 3.400 M MECH - RM 701 2 3 MECH - RM 605 M 3.400 20/1 B 20/1 3.400 M MECH - RM 703 4 5 MECH - RM 607 M 3.400 2011 C 20/1 3.400 M MECH - RM 705 6 7 MECH - RM 609 M 3.400 20/1 1 A 20/1 3.400 M MECH - RM 707 8 9 MECH - RM 611 M 3.400 20/1 j B 1 20/1 3.400 M MECH - RM 709 10 11 MECH - RM 613 M 3.400 20/1 C 20/1 3.400 M MECH - RM 711 12 13 MECH - RM 615 M 3.400 20/1 A 20/1 3.400 M MECH - RM 713 14 15 MECH - RM 617 M 3.400 20/1 B 20/1 1400 M MECH - RM 715 16 17 MECH - RM 619 M 3.400 20/1 C 20/1 3.400 M MECH - RM 717 18 19 MECH - RM 621 M 3.400 20/1 A 20/1 3.400 M MECH - RM 719 20 21 MECH - RM 623 M 3.400 20/1 B 20/1 3.400 M MECH - RM 721 22 23 MECH - RM 602 M 3.400 20/1 C 20/1 3.400 M MECH - RM 723 24 25 MECH - RM 604 M 3.400 20/1 A 20/1 3.400 M MECH - RM 702 26 27 MECH - RM 606 M 3.400 20/1 B 20/1 3.400 M MECH - RM 704 28 29 MECH - RM 608 M 3.400 20/1 C 2011 3.400 M MECH - RM 706 30 31 MECH - RM 610 M 3.400 20/1 A 20/1 3.400 M MECH - RM 708 32 33 MECH - RM 612 M 3,400 20/1 B 20/1 3.400 M MECH - RM 710 34 35 MECH - RM 614 M 3.400 20/1 C 20/1 3.400 M MECH - RM 712 36 37 MECH - RM 616 M 3.400 20/1 A 20/1 3.400 M MECH - RM 714 38 39 MECH - RM 618 M 3.400 20/1 B 20/1 3.400 M MECH - RM 716 40 41 SPARE S - 20/1 C 20/1 3.400 M MECH - RM 718 42 43 SPARE S - 20/1 A 2011 - S SPARE 44 45 SPARE S - 20/1 B 20/1 - S SPARE 46 47 SPARE S - 20/1 C 20/1 - S SPARE 48 49 SPARE S - 20/1 A 20/1 - S SPARE 50 51 SPARE S - 20/1 B 20/1 - S SPARE 52 53 SPARE S - 20/1 C 20/1 - S SPARE 54 55 DWH-6-1 (WTR HTR) (LEVEL 6) - - WH - - 4.500 - - 15/3 - - A 100/3 - - 31.698 - - P - - PANEL HR6A (VIA 75KVAXFMR T-6H) _ - 56 57 B 58 59 C 60 PHASE LOAD PHASE A= 60.05 KVA PHASE B= 59.21 KVA PHASE C= 56.35 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HP6 139.40 4.50 3.40 143.90 KVA 173.08 AMP PANEL HR6A 0.90 1.18 27.62 2.00 1.18 31.70 KVA 38.13 AMP CONN. LOAD 0.90 140.58 4.50 27.62 2.00 3.40 175.60 KVA 211.21 AMP CALC. LOAD 0.90 140.58 1 4.50 13.05 1 2.00 1 1 1 0.85 161.88 KVA 194.71 AMP PANEL HR2C LOCATION: ELEC RM 2ND FLR SERVING: HOTEL LOADS FED FROM: HR26 208/120 VOLT 225 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 5,728 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE F KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 GUEST ROOM 301 HM 0.210 20/1 A 20/1 0.210 HM GUEST ROOM 321 2 3 GUEST ROOM 301 HM 0.210 20/1 B 2011 0.210 HM GUEST ROOM 321 4 5 GUESTROOM301 HM 0.210 20/1 C 20/1 0.210 HM GUESTROOM321 6 7 GUEST ROOM 303 HM 0.202 20/1 A 20/1 0.210 HM GUEST ROOM 323 8 9 GUEST ROOM 303 HM 0.202 20/1 B 20/1 0.210 HM GUEST ROOM 323 10 11 GUEST ROOM 303 HM 0.202 20/1 C 20/1 0.210 HM GUEST ROOM 323 12 13 GUESTROOM305 HM 0.202 20/1 A 20/1 - S SPARE 14 15 GUESTROOM305 HM 0.202 20/1 B 20/1 - S SPARE 16 17 GUEST ROOM 305 HM 0.202 20/1 C 2011 - S SPARE 18 19 GUESTROOM307 HM 0.202 20/1 A 20/1 - S SPARE 20 21 GUESTROOM307 HM 0.202 20/1 B 20/1 - S SPARE 22 23 GUESTROOM307 HM 0.202 20/1 C 20/1 - S SPARE 24 25 GUEST ROOM 309 HM 0.202 20/1 A 2011 - S SPARE 26 27 GUEST ROOM 309 HM 0.202 20/1 B 20/1 - S SPARE 28 29 GUEST ROOM 309 HM 0.202 20/1 C 20/1 - S SPARE 30 31 GUESTROOM311 HM 0.202 20/1 A 20/1 - S SPARE 32 33 GUESTROOM311 HM 0.202 20/1 B 20/1 - S SPARE 34 35 GUESTROOM311 HM 0.202 20/1 C 20/1 - S SPARE 36 37 GUEST ROOM 313 HM 0.202 20/1 A 20/1 - S SPARE 38 39, GUEST ROOM 313 HM 0.202 20/1 B 2011 - S SPARE 40 41 GUEST ROOM313 HM 0.202 2011 C 20/1 - S SPARE 42 43 GUESTROOM315 HM 0.202 20/1 A 20/1 - S SPARE 44 45 GUESTROOM315 HM 0.202 20/1 B 2011 - S SPARE 46 47 GUESTROOM315 HM 0.202 20/1 C 20/1 - S SPARE 48 49 GUESTROOM317 HM 0.202 20/1 A 2011 - S SPARE 50 51 GUEST ROOM 317 HM 0.202 2011 B 20/1 - S SPARE 52 53 GUEST ROOM 317 HM 0.202 20/1 C 20/1 - S SPARE 54 55 GUEST ROOM319 HM 0.202 20/1 A 20/1 - S SPARE 56 57 GUEST ROOM 319 HM 0.202 20/1 B 20/1 - S SPARE 58 59 GUESTROOM319 HM 0.202 20/1 C 20/1 - S SPARE 60 PHASE LOAD PHASE A= 2.45 KVA PHASE B= 2.45 KVA PHASE C= 2.45 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 7.34 7.34 KVA 20.38 AMP CALC. LOAD 3.67 3.67 KVA 10.19 AMP PANEL HP4 LOCATION: ELEC RM 4TH FLR SERVING: HOTEL LOADS FED FROM: BUS DUCT BD-1 480/277 VOLT 400 AMP MAIN LUGS ONLY SCCR: 50,000 A 3 PHASE AFC: 33,709 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 MECH - RM 401 M 3.400 20/1 A 20/1 3.400 M MECH - RM 501 2 3 MECH - RM 405 M 3.400 20/1 B 20/1 3.400 M MECH - RM 503 4 5 MECH - RM 407 M 3.400 20/1 C 20/1 3.400 M MECH - RM 505 6 7 MECH - RM 409 M 3.400 20/1 A 2011 3.400 M MECH - RM 507 8 9 MECH - RM 411 M 3.400 20/1 B 20/1 3.400 M MECH - RM 509 10 11 MECH - RM 413 M 3.400 20/1 C 20/1 3.400 M MECH - RM 511 12 13 MECH - RM 415 M 3.400 2011 A 20/1 3.400 M MECH - RM 513 14 15 MECH - RM 417 M 3.400 20/1 B 20/1 3.400 M MECH - RM 515 16 17 MECH - RM 419 M 3.400 20/1 C 20/1 3.400 M MECH - RM 517 18 19 MECH - RM 421 M 3.400 20/1 A 20/1 3.400 M MECH - RM 519 20 21 MECH - RM 423 M 3.400 20/1 B 20/1 3.400 M MECH - RM 521 22 23 MECH - RM 402 M 3.400 20/1 C 2011 3.400 M MECH - RM 523 24 25 MECH - RM 404 M 3.400 20/1 A 1 1 20/1 3.400 M MECH - RM 502 26 27 MECH - RM 406 M 3.400 2011 B 1 20/1 3.400 M MECH - RM 504 28 29 MECH - RM 408 M 3.400 20/1 C 20/1 3.400 M MECH - RM 506 30 31 MECH - RM 410 M 3.400 20/1 A 20/1 3.400 M MECH - RM 508 32 33 MECH - RM 412 M 3.400 20/1 B 20/1 3.400 M MECH - RM 510 34 35 MECH - RM 414 M 3.400 20/1 C 20/1 3.400 M MECH - RM 512 36 37 MECH - RM 416 M 3.400 20/1 A 20/1 3.400 M MECH - RM 514 38 39 MECH - RM 418 M 3.400 20/1 B 20/1 3.400 M MECH - RM 516 40 41 SPARE S - 20/1 C 20/1 3.400 M MECH - RM 518 42 43 SPARE S - 20/1 A 20/1 - S SPARE 44 45 SPARE S - 20/1 B 1 20/1 - S SPARE 46 47 SPARE S - 20/1 C 20/1 - S SPARE 48 49 SPARE S - 20/1 A 20/1 - S SPARE 50 51 SPARE S - 20/1 B 20/1 - S SPARE 52 53 SPARE S - 20/1 C 20/1 - S SPARE 54 55 SPARE S - 20/1 A 100/3 - - 29,340 - - P - - PANEL HR4A (VIA 75KVAXFMRT-4H) - - 56 57 SPARE S - 20/1 B 58 59 SPARE S - 20/1 C 60 PHASE LOAD PHASE A= 58.14 KVA PHASE B= 57.32 KVA PHASE C= 53.28 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HP4 139.40 3.40 139AO KVA 167.67 AMP PANEL HR4A 0.90 26.44 2.00 29.34 KVA 35.29 AMP CONN. LOAD 0.90 139.40 26.44 2.00 3.40 168.74 KVA 202.96 AMP CALC. LOAD 0.90 139,40 12.58 1 2.00 1 0.85 1 155.73 KVA 1 187.31 AMP PANEL HR4A LOCATION: ELEC RM 4TH FLR SERVING' HOTEL LOADS FED FROM: HP4 (VIA75 KVAXFMR T-4H) 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 225 AMP MAIN BREAKER AFC: 5,894 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 GUESTROOM405 HM 0.202 20/1 A 1 1 20/1 0.221 HM GUEST ROOM402 2 3 GUESTROOM405 HM 0.202 20/1 B 20/1 0.221 HM GUEST ROOM402 4 5 GUESTROOM405 HM 0.202 20/1 C 20/1 0.221 HM GUEST ROOM402 6 7 GUESTROOM407 HM 0.200 20/1 A 20/1 0.220 Hill GUEST ROOM404 8 9 GUESTROOM407 HM 0.200 20/1 B 20/1 0.220 HM GUEST ROOM404 10 11 GUESTROOM407 HM 0.200 2011 C 20/1 0.220 HM GUESTROOM404 12 13 GUESTROOM409 HM 0.203 20/1 A 20/1 0.203 HM GUESTROOM406 14 15 GUESTROOM409 HM 0.203 2011 B 20/1 0.203 HM GUESTROOM406 16 17 GUESTROOM409 HM 0.203 20/1 C 20/1 0.203 HM GUESTROOM406 18 19 GUESTROOM411 HM 0.203 20/1 A 20/1 0.203 HM GUESTROOM408 20 21 GUESTROOM411 HM 0.203 20/1 B 2011 0.203 HM GUESTROOM408 22 23 GUESTROOM411 HM 0.203 20/1 C 20/1 0.203 HM GUEST ROOM408 24 25 GUESTROOM413 HM 0.200 20/1 A 20/1 0.200 HM GUEST ROOM 410 26 27 GUESTROOM413 HM 0.200 20/1 B 20/1 0.200 HM GUEST ROOM410 28 29 GUESTROOM413 HM 0.200 20/1 C 20/1 0.200 HM GUEST ROOM410 30 31 GUESTROOM415 HM 0.200 20/1 A 20/1 0.200 HM GUESTROOM412 32 33 GUESTROOM415 HM 0.200 20/1 B 20/1 0.200 HM GUESTROOM412 34 35 GU EST ROOM 415 HM 0.200 2011 C 20/1 0.200 HM GUEST ROOM 412 36 37 GUESTROOM417 HM 0.203 20/1 A 20/1 0.203 HM GUEST ROOM414 38 39GUESTROOM417 HM 0.203 20/1 B 20/1 0.203 HM GUESTROOM414 40 41 GUESTROOM417 HM 0.203 20/1 C 20/1 0.203 HM GUESTROOM414 42 43 GUESTROOM419 HM 0.203 2011 A 20/1 0.222 HM GUESTROOM416 44 45 GUESTROOM419 HM 0.203 20/1 B 20/1 0.222 HM GUEST ROOM416 46 47 GUESTROOM419- HM 0.203 20/1 C 20/1 0.222 HM GUEST ROOM 416 48 49 GUESTROOM421 HM 0.200 20/1 A 20/1 0.257 HM GUEST ROOM 418 50 51 GUESTROOM421 HM 0.200 20/1 B 20/1 0.257 HM GUESTROOM418 52 53 GU EST ROOM 421 HM 0.200 20/1 C 20/1 0.257 HM GUEST ROOM 418 54 55 GUESTROOM423 HM 0.191 20/1 A 20/1 0.180 R RCPT- ELECRM 56 57 GUESTROOM423 HM 0.191 20/1 B 20/1 - S SPARE 58 59 GUESTROOM423 HM 0.191 20/1 C 20/1 - S SPARE 60 PHASE LOAD PHASE A= 10.54 KVA PHASE B= 9.72 KVA PHASE C= 9.08 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HR4A 0.18 11.80 11.98 KVA 33.26 AMP PANEL HR4B 0.72 14.64 2.00 17.36 KVA 48.18 AMP CONN. LOAD 0.90 26.44 1 2.00 29.34 KVA 81 A4 AMP CALC. LOAD 0.90 12.58 1 2.00 15A8 KVA 42.96 AMP REQUIRED FEED-THRU LUGS OPTIONS: PANEL HP2 LOCATION: ELEC RM 2ND FLR SERVING: HOTEL LOADS FED FROM: BUS DUCT BD-1 480/277 VOLT 400 AMP MAIN LUGS ONLY SCCR: 50,000 A 3 PHASE AFC: 38,419 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 LTG- HOTEL COR LVL 3-9 L 3.717 2011 A 20/1 3.400 M MECH - RM301 2 3 LTG - HOTEL COR LVL 3-9 L 3.186 20/1 B 1 20/1 3.400 M MECH - RM 303 4 5 LTG - HOTEL COR LVL 3-9 L 3.771 20/1 1 C 20/1 3.400 M MECH - RM 305 6 7 LTG - HOTEL 2ND FLR L 1.890 2011 A 20/1 3.400 M MECH - RM 307 8 9 LTG - HOTEL 2ND FLR M 1.595 20/1 B 20/1 3.400 M MECH - RM 309 10 11 LTG - HOTEL 2ND FLR CORRIDORS L 0.817 20/1 C 2011 3.400 M MECH - RM 311 12 13 LTG- HOTEL 2ND FLR ROOMS L 3.536 20/1 A 20/1 3.400 M MECH - RM 313 14 15 LTG - HOTEL 2ND FLR L 2.014 20/1 B 20/1 3.400 M MECH - RM 315 16 17 LTG - HOTEL 2ND FLR L 2.191 20/1 C 20/1 3.400 M MECH - RM 317 18 19 WSHP - 2- 6H M 2.742 15/1 A 20/1 3.400 M MECH - RM 319 20 21 WSHP - 2-11 H M 1.551 15/1 B 20/1 3.400 M MECH - RM 321 22 23 WSHP - 2-9H M 2.742 15/1 C 20/1 3.400 M MECH - RM 323 24 25 WSHP - 2-41-1 M 2.742 15/1 A 20/1 3.400 M MECH - RM 302 26 27 WSHP - 2-1 OH M 2.742 15/1 B 20/1 3.400 M MECH - RM 304 28 29 WSHP - 2-7H M 1.551 15/1 C 20/1 3.400 M MECH - RM 306 30 31 WSHP - 2-5H M - 7.396 - 1513 - - A 20/1 3.400 M MECH - RM 308 32 33 B 20/1 3.400 M MECH - RM 310 34 35 C 20/1 3.400 M MECH - RM 312 36 37 WSHP - 2-3H M 11.473 - - 20/3 - - A 20/1 3.400 M MECH - RM 314 38 39 B 20/1 3.400 M MECH - RM 316 40 41 C 20/1 - S SPARE 42 43 WSHP - 2-21-1 - - M - - 11.473 - - 20/3 - - A 20/1 - S SPARE 44 45 B 20/1 - S SPARE 46 47 C 20/1 - S SPARE 48 49 WSHP-2-11-1 - M - - 8.397 - - 15/3 - - A 20/1 - S SPARE 50 51 B 20/1 - S SPARE 52 531- C 20/1 - S SPARE 54 55 DHU-1 (NOTE 1) - M - - 55.174 - 100/3 - - A 60/3 - 30.285 - - M - - CCFC-1 - - 56 57 B 58 59 C 60 PHASE LOAD PHASE A= 79.83 KVA PHASE B= 76.29 KVA PHASE C= 72.87 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 21.12 207.86 55.17 228.99 KVA 275.43 AMP CALC. LOAD 26.40 207.86 13.79 248.06 KVA 298.37 AMP NOTES: 1.) PROVIDE SINGLE FEEDER TO FUSED DISCONNECT AND INDIVIDUAL FEEDERS TO EACH OF THREE SINGLE POINT OF CONNECTIONS, REFER TO ELECTRICAL SCHEDULES FOR MECHANICAL EQUIPMENT SHEET FOR MORE INFORMATION. PANEL HR2A LOCATION: ELEC RM2ND FLR SERVING: HOTEL LOADS FED FROM: BUS DUCT BD-1 (VIA75 KVAXFMR T-2H) 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 225 AMP MAIN BREAKER AFC: 5,863 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 RCPT- HOUSEKEEPING 3RD FLR R 0.360 20/1 A 20/1 0.720 R RCPT- RM226, 226B, 225 2 3 RCPT- ICE MAKER 3RD FLR D 1.000 *20/1 B 20/1 0.720 R RCPT- RM226, 226B, 225 4 5 RCPT- RM 134 R 0.360 20/1 C 20/1 0.900 R RCPT- 226, 226E 6 7 RCPT - RM 134 R 0.360 20/1 A 20/1 0.900 R RCPT - 200H, 227,228 8 9 1 RCPT- RM 134 R 0.360 20/1 B 2011 0.900 R RCPT- 200H, 227,228 10 11 SPARE S - 20/1 C 20/1 0.900 R RCPT- 200H, 227,228 12 13 1 RCPT-POOL CHEM CONTROLLER R 1.500 20/1 A 20/1 1.500 R RCPT -RM239 HOT CART 14 15 RCPT- POOL CHEM FEED PUMP R 1.500 20/1 B 20/1 1.500 R RCPT- RM 239 HOT CART 16 17 RCPT- POOL CHEM FEED PUMP R 1.500 2011 C 20/1 1.500 R RCPT- RM 239 HOT CART 18 19 POOL PUMP - M - 5.000 - 30/2 - A 20/1 1.200 R RCPT- FRIDGE 20 21 B 2011 0.720 R RCPT - RM 260 22 23 POOL HEATER - H - 5.000 - 30/2 - C 20/1 0.720 R RCPT- RM 196, 200, 234, 314 24 25 A 20/1 0.900 R RCPT - RM 229, 230 26 27 RCPT - RM 134 R 0.360 20/1 B 20/1 0.900 R RCPT - RM 229,230 28 29 RCPT - RM 134 R 0.360 2011 C 20/1 0.900 R RCPT - RM 229,230 30 31 RCPT - RM 134 R 0.360 20/1 A 20/1 0.900 R RCPT - RM 231, 232 32 33 WALK IN COOLER D 1.800 20/1 B 20/1 0.900 R RCPT- RM231, 232 34 35 ICE MACHINE D 1.200 20/1 C 20/1 1.620 R RCPT- HOTEL RISER FLRS 3-11 36 37 RCPT-239 R 0.720 20/1 A 20/1 1.800 R RCPT- HOTEL RISER FLRS 3-11 38 39 SPARE S - 20/1 20/1 1,620 R RCPT- HOTEL RISER FLRS 3-11 40 41 SPARE S - 2011 20/1 1.620 R RCPT- HOTEL RISER FLRS 3-11 42 43 SPARE S - 20/1 qA 20/1 1.620 R RCPT- HOTEL STAIRS FLRS 3-11 44 45 SPARE S - 20/120/1 0.980 R RCPT - HOTEL ELEV LBY FLRS 2-11 46 47 SPARE S - 20/150/2 - 8.000 - D - AV EQUIP RACK - 48 49 SPARE S - 20/1 50 51 SPARE S - 20/1 B 1 20/1 - S SPARE 52 53 SPARE S - 20/1 C 2011 - S SPARE 54 55 SPARE S - 20/1 A 20/1 - S SPARE 56 57 SPARE S - 20/1 B 20/1 - S SPARE Sg 59 SPARE S - 20/1 C 20/1 - S SPARE 60 PHASE LOAD PHASE A= 26.17 KVA PHASE B= 20.09 KVA PHASE C= 22.41 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HR2A 33.68 5.00 5.00 12.00 5.00 55.68 KVA 154.55 AMP PANEL HR2B 12.98 12.98 KVA 36.01 AMP CONN. LOAD 33.68 5.00 5.00 12.98 12.00 5.00 68.66 KVA 190.57 AMP CALC. LOAD 1 21.84 j 5.00 15.00 16.49 j 12.00 1 1.25 51.58 KVA 143.16 AMP REQUIRED FEED-THRU LUGS OPTIONS: NOTES: * = GFCI CIRCUIT BREAKER. PANEL HR213 LOCATION: ELEC RM 2ND FLR SERVING: HOTEL LOADS FED FROM: HR2A 208/120 VOLT 225 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 6,795 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 SPARE S - 2011 A 20/1 0.220 HM GUESTROOM302 2 3 SPARE S - 20/1 B 20/1 0.220 HM GUESTROOM302 4 5 SPARE S - 20/1 C 20/1 0.220 HM GUESTROOM302 6 7 SPARE S - 20/1 A 20/1 0.220 HM GUESTROOM304 8 9 SPARE S - 2011 B 2011 0.220 HM GUEST ROOM 304 10 11 SPARE S - 20/1 C 20/1 0.220 HM GUEST ROOM 304 12 13 SPARE S - 20/1 A 20/1 0.202 HM GUEST ROOM 306 14 15 SPARE S - 20/1 B 2011 0.202 HM GUEST ROOM 306 16 17 SPARE S - 20/1 C 20/1 0.202 HM GUESTROOM306 18 19 SPARE S - 20/1 A 20/1 0.202 HM GUEST ROOM 308 20 21 SPARE S - 20/1 B 20/1 0.202 HM GUEST ROOM 308 22 23 SPARE S - 20/1 C 20/1 0.202 HM GUEST ROOM 308 24 25 SPARE S - 2011 A 20/1 0.200 HM GUEST ROOM 310 26 27 SPARE S - 20/1 B 20/1 0.200 HM GUESTROOM310 28 29 SPARE S - 20/1 C 20/1 0.200 HM GUEST ROOM 310 30 31 SPARE S - 20/1 A 20/1 0.200 HM GUEST ROOM 312 32 33 SPARE S - 20/1 B 20/1 0.200 HM GUEST ROOM 312 34 35 SPARE S - 20/1 C 20/1 0.200 HM GUEST ROOM 312 36 37 SPARE S - 20/1 A 2011 0.202 HM GUEST ROOM 314 38 39 SPARE S - 20/1 B 20/1 0.202 HM GUEST ROOM 314 40 41 SPARE S - 20/1 C 20/1 0.202 HM GUEST ROOM 314 42 43 SPARE S - 20/1 A 20/1 0.222 HM GUEST ROOM 316 44 45 SPARE S - 20/1 B 20/1 0.222 HM GUEST ROOM 316 46 47 SPARE S - 20/1 C 20/1 0.222 HM GUEST ROOM 316 48 49 SPARE S - 20/1 A 20/1 0.209 HM GUEST ROOM 318 50 51 SPARE S - 20/1 B 20/1 0.209 HM GUEST ROOM 318 52 53 SPARE S - 20/1 C 20/1 0.209 HM GUEST ROOM 318 54 55 SPARE S - 20/1 A 20/1 - S SPARE 56 57 SPARE S - 20/1 B 20/1 - S SPARE 58 59 SPARE S - 2011 C 20/1 - S SPARE 60 PHASE LOAD PHASE A= 4.33 KVA PHASE B= 4.33 KVA PHASE C= 4.33 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HR213 5.63 5.63 KVA 15.63 AMP PANEL HR2C 7.34 7.34 KVA 20.38 AMP CONN. LOAD 12.98 1 1 1 12.98 KVA 36.01 AMP CALC. LOAD 6.49 6.49 KVA 18.01 AMP REQUIRED 4 IAE WITH OPTIONS:PA _ NEC AV i RECEIVED DEC 0 3 2015 CITY OF TUKWil A City of�Tul Wila OCT 15 2015 DING DIVISION _ CENTER �UIL PERMIT PANEL SCHEDULE INDEX PANEL NAME PANEL NAME PANEL NAME HR4B HR2C HP2 HR4C HP4 HR2A HP6 HR4A HR26 ISSUE 0 Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB :YPLAN PHASE ELECTRICAL PERMIT PROJECT NUMBER < GWA NO. PROJECT {L W 3: p w Y a o ui W J pY CD Q H z � N N �M VJ Q CONSULTANT REGISTRATION 15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 8264447 FAX: (206) 826.4446 SHEET TITLE AND NUMBER ELECTRICAL PANEL SCHEDULES E8.06 a+ 3 v U) J D 0 W C) V) PANEL HR8C LOCATION: ELEC RM 8TH FLR SERVING: HOTEL LOADS FED FROM: HR813 208/120 VOLT 225 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 5,472 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 RCPT- HOUSEKEEPING 8TH FLR R 0.360 20/1 A 20/1 0.365 HM GUEST ROOM 801 2 3 RCPT- ICE MAKER 8TH FLR D 1,000 *20/1 B 20/1 0.365 HM GUEST ROOM 801 4 5 RCPT - HOUSEKEEPING 9TH FLR R 0.360 20/1 C 20/1 0.365 HM GUESTROOM801 6 7 RCPT- ICE MAKER 9TH FLR D 1.000 *20/1 A 20/1 0.365 HM GUEST ROOM 801 8 9 SPARE S - 20/1 B 20/1 0.216 HM GUEST ROOM 901 10 11 SPARE S - 20/1 C 20/1 0.216 HM GUEST ROOM 901 12 13 SPARE S - 20/1 A 20/1 0.216 HM GUEST ROOM 901 14 15 SPARE S - 2011 B 2011 0.202 HM GUEST ROOM 903 16 17 SPARE S - 20/1 C 20/1 0.202 HM GUEST ROOM 903 18 19 SPARE S - 20/1 A 20/1 0.202 HM GUEST ROOM 903 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 2011 - S SPARE 24 25 SPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 2011 B 20/1 - S SPARE 28 29 SPARE S - 20/1 C 20/1 - S SPARE 30 31 SPARE S - 20/1 A 20/1 S SPARE 32 33 SPARE S - 20/1 B 20/1 - S SPARE 34 35 SPARE S - 20/1 C 20/1 - S SPARE 36 37 SPARE S - 20/1 : A 20/1 - S SPARE 38 39 SPARE S - 20/1 B 20/1 - S SPARE 40 41 SPARE S - 20/1 C 20/1 - S SPARE 42 43 SPARE S - 20/1 A 20/1 - S SPARE 44 45 SPARE S - 20/1 B 20/1 - S SPARE 46 47 SPARE S - 2011 C 2011 - S SPARE 48 49 SPARE S - 20/1 A 20/1 - S SPARE 50 51 SPARE S - 20/1 B 20/1 - S SPARE 52 53 SPARE S - 20/1 C 20/1 - S SPARE 54 55 SPARE I I S - 20/1 A 20/1 - S SPARE 56 57 SPARE S - 20/1 B 20/1 - S SPARE 58 59 SPARE S - 2011 C 20/1 - S SPARE 60 PHASE LOAD PHASE A= 2.51 KVA PHASE B= 1.78 KVA PHASE C= 1.14 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.72 2.71 2.00 5.43 KVA 15.08 AMP CALC. LOAD 0.72 1.36 2.00 4.08 KVA 11.32 AMP NOTES: ' = GFCI CIRCUIT BREAKER. PANEL HP10 LOCATION: ELEC RM 10TH FLR SERVING: HOTEL LOADS FED FROM: BUS DUCT BD-1 480/277 VOLT 400 AMP MAIN LUGS ONLY SCCR: 50,000 A 3 PHASE AFC: 31,422 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 MECH - RM 1001 M 3.400 20/1 A 20/1 3.400 M MECH - RM 1101 2 3 MECH - RM 1005 M 3.400 20/1 B 20/1 3.400 M MECH - RM 1103 4 5 MECH - RM 1007 M 3.400 20/1 C 20/1 3.400 M MECH - RM 1105 6 7 MECH - RM 1009 M 3.400 20/1 A 20/1 3.400 M MECH - RM 1107 8 9 MECH - RM 1011 M 3.400 20/1 B 20/1 3.400 M MECH - RM 1109 10 11 MECH - RM 1013 M 3.400 20/1 C 20/1 3.400 M MECH - RM 1111 12 13 MECH - RM 1015 M 3.400 2011 A 20/1 3.400 M MECH - RM 1113 14 15 MECH - RM 1017 M 3.400 2011 B 20/1 3.400 M MECH - RM 1115 16 17 MECH - RM 1019 M 3.400 20/1 C 20/1 3.400 M MECH - RM 1117 18 19 MECH - RM 1021 M 3.400 20/1 A 2011 3.400 M MECH - RM 1119 20 21 MECH - RM 1023 M 3.400 20/1 B 20/1 3.400 M MECH - RM 1121 22 23 MECH - RM 1002 M 3.400 20/1 C 20/1 3.400 M MECH - RM 1123 24 25 MECH - RM 1004 M 3.400 20/1 A 20/1 3.400 M MECH - RM 1102 26 27 MECH - RM 1006 M 3.400 20/1 B 20/1 3.400 M MECH - RM 1104 28 29 MECH - RM 1008 M 3.400 20/1 C 20/1 3.400 M MECH - RM 1106 30 31 MECH - RM 1010 M 3.400 20/1 A 20/1 3.400 M MECH - RM 1108 32 33 IVECH - RM 1012 M 3.400 20/1 B 20/1 3.400 M MECH - RM 1110 34 35 MECH - RM 1014 M 3.400 20/1 C 20/1 3.400 M MECH - RM 1112 36 37 MECH - RM 1016 M 3.400 2011 A 20/1 3.400 M MECH - RM 1114 38 39 MECH - RM 1018 M 3.400 2011 B 20/1 3.400 M MECH - RM 1116 40 41 SPARE S - 20/1 C 20/1 3.400 M MECH - RM 1118 42 43 SPARE S - 20/1 A 20/1 - S SPARE 44 45 SPARE S - 20/1 B 20/1 - S SPARE 46 47 SPARE S - 20/1 C 20/1 - S SPARE 48 49 RCP-1 (RECIRC PUMP) (LEVEL 19) - M - - 2.494 - - 15/3 - - A 20/1 - S SPARE 50 51 B 20/1 - S SPARE 52 53 C 20/1 - S SPARE 54 55 DWH-11-1 (WTR HTR) (LEVEL 11) - - WH - - 4.500 - - 15/3 - - A 100/3 - - 42.091 - - P - PANEL HR10A(VIA75KVAXFMR T-10H) - 56 57 B lc 58 59 60 PHASE LOAD PHASE D 63.64 KVA PHASE B= 62.77 KVA PHASE C= 62.07 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HP10 141.89 4.50 3.40 146.39 KVA 176.08 AMP PANEL HR10A 0.90 1.18 38.01 2.00 1.18 42.09 KVA 50.63 AMP CONN. LOAD 1 1 0.90 143.07 1 1 4.50 38.01 2.00 1 1 3.40 188.49 KVA 226.71 AMP CALC. LOAD 1 1 0.90 143.07 1 14.50 17.20 1 2.00 1 1 1 0.85 168.53 KVA 202.71 AMP PANEL HR10A LOCATION: ELEC RM 10TH FLR SERVING: HOTEL LOADS FED FROM: HP10 (%AA75 KVAXFMR T-10H) 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 225 AMP MAIN BREAKER AFC: 5,892 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 GUESTROOM1005 HM 0.500 2011 A 1 1 20/1 0.220 HM GUEST ROOM 1002 2 3 GUEST ROOM 1005 . HM 0.360 20/1 B 1 20/1 0.220 HM GUEST ROOM 1002 4 5 GUEST ROOM 1005 HM 0.720 20/1 1 C 20/1 0.220 HM GUEST ROOM 1002 6 7 GUEST ROOM 1007 HM 0.500 2011 A 20/1 0.220 HM GUEST ROOM 1004 8 9 GUEST ROOM 1007 HM 0.360 20/1 B 20/1 0.220 HM GUEST ROOM 1004 10 11 GUEST ROOM 1007 HM 0.720 20/1 C 20/1 0.220 HM GUEST ROOM 1004 12 13 GUEST ROOM 1009 HM 0.500 20/1 A 20/1 0.200 HM GUEST ROOM 1006 14 15 GUEST ROOM 1009 HM 0.360 20/1 1 B 1 1 20/1 0.200 HM GUEST ROOM 1006 16 17 GUEST ROOM 1009 HM 0.720 20/1 1 C 20/1 0.200 HM GUEST ROOM 1006 18 19 GUEST ROOM 1011 HM 0.500 20/1 A 1 1 20/1 0.200 HM GUEST ROOM 1008 20 21 GUEST ROOM 1011 HM 0.360 2011 1 B 1 20/1 0.200 HM GUEST ROOM 1008 22 23 GUEST ROOM 1011 HM 0.720 2011 C 20/1 0200 HM GUEST ROOM 1008 24 25 GUEST ROOM 1013 HM 0.500 20/1 A 20/1 0.200 HM GUEST ROOM 1010 26 27 GUEST ROOM 1013 HM 0.720 2011 B 20/1 0.200 HM GUEST ROOM 1010 28 29 GUEST ROOM 1013 HM 0.720 20/1 C 20/1 0.200 HM GUEST ROOM 1010 30 31 GUEST ROOM 1015 HM 0.500 20/1 A 20/1 0.200 HM GUEST ROOM 1012 32 33 GUEST ROOM 1015 HM 0.720 2011 B 20/1 0.200 HM GUEST ROOM 1012 34 35 GUEST ROOM 1015 HM 0.720 20/1 C 20/1 0.200 HM GUEST ROOM 1012 36 37 GUEST ROOM 1017 HM 0.500 20/1 A 20/1 0.200 HM GUEST ROOM 1014 38 39 GUEST ROOM 1017 HM 0.360 20/1 B 2011 0.200 HM GUEST ROOM 1014 40 41 GUEST ROOM 1017 HM 0.720 20/1 C 20/1 0.200 HM GUEST ROOM 1014 42 43 GUEST ROOM 1019 HM 0.500 20/1 A 20/1 0.215 HM GUESTROOM1016 44 45 GUEST ROOM 1019 HM 0.360 2011 B 20/1 0.215 HM GUEST ROOM 1016 46 47 GUEST ROOM 1019 HM 0.720 20/1 C 20/1 0.215 HM GUEST ROOM 1016 48 49 GUEST ROOM 1021 HM 0.500 2011 A 20/1 0.257 HM GUEST ROOM 1018 50 51 GUEST ROOM 1021 HM 0.720 20/1 B 20/1 0.257 HM GUEST ROOM 1018 52 53 GUEST ROOM 1021 HM 0.720 20/1 C 20/1 0.257 HM GUEST ROOM 1018 54 55 GUEST ROOM 1023 HM 0.500 2011 A 20/1 0.180 R RCPT- ELEC RM 56 57 GUEST ROOM 1023 HM 0.720 20/1 B 20/1 - S SPARE 58 59 GUEST ROOM 1023 HM 0.720 20/1 C 20/1 - S SPARE 60 PHASE LOAD PHASE A= 13.71 KVA PHASE B= 12.84 KVA PHASE C= 15.54 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HR10A 0.18 22.98 23.16 KVA 64.27 AMP PANEL HR10B 0.72 1.18 15.04 2.00 1.18 18.94 KVA 52.56 AMP CONN. LOAD 1 1 0.90 1.18 1 38.01 1 2.00 1 1.18 1 42.09 KVA 116.83 AMP CALC. LOAD 1 0.90 1.18 1 17.20 1 2.00 0.30 1 21.58 KVA 59.90 AMP REQUIRED FEED-THRU LUGS OPTIONS: PANEL HP8 LOCATION: ELEC RM 8TH FLR SERVING: HOTEL LOADS FED FROM: BUS DUCT BD-1 480/277 VOLT 400 AMP MAIN LUGS ONLY SCCR: 50,000 A 3 PHASE AFC: 31,898 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 MECH - RM 801 M 3.400 20/1 A 20/1 3.400 M MECH - RM 901 2 3 MECH - RM 805 M 3.400 20/1 B 20/1 3.400 M MECH - RM 903 4 5 MECH - RM 807 M 3.400 20/1 C 20/1 3.400 M MECH - RM 905 6 7 MECH - RM 809 M 3.400 20/1 A 20/1 3.400 M MECH - RM 907 8 9 MECH - RM 811 M 3.400 2011 B 20/1 3.400 M MECH - RM 909 10 11 MECH - RM 813 M 3.400 20/1 C 20/1 3.400 M MECH - RM 911 12 13 MECH - RM 815 M 3.400 20/1 A 20/1 3.400 M MECH - RM 913 14 15 MECH - RM 817 M 3,400 20/1 B 20/1 3.400 M MECH - RM 915 16 17 MECH - RM 819 M 3.400 2011 C 20/1 3.400 M MECH - RM 915 18 19 MECH - RM 821 M 3.400 20/1 A 20/1 3.400 M MECH - RM 917 20 21 MECH - RM 823 M 3.400 2011 B 20/1 3.400 M MECH - RM 919 22 23 MECH - RM 802 M 3.400 20/1 C 20/1 3.400 M MECH - RM 921 24 25 MECH - RM 804 M 3.400 20/1 A 20/1 3.400 M MECH - RM 923 26 27 MECH - RM 806 M 3.400 20/1 B 2011 3.400 M MECH - RM 902 28 29 MECH - RM 808 M 3.400 2011 C 20/1 3.400 M MECH - RM 904 30 31 MECH - RM 810 M 3.400 20/1 A 20/1 3.400 M MECH - RM 906 32 33 MECH - RM 812 M 3.400 20/1 B 20/1 3.400 M MECH - RM 908 34 35 MECH - RM 814 M 3.400 20/1 C 20/1 3.400 M MECH - RM 910 36 37 MECH - RM 816 M 3.400 20/1 A j j 20/1 3.400 M MECH - RM 912 38 39 MECH - RM 818 M 3.400 20/1 B 20/1 3.400 M MECH - RM 914 40 41 SPARE S - 20/1 C 20/1 3.400 M MECH - RM 916 42 43 SPARE S - 20/1 A 20/1 3.400 M MECH - RM 918 44 45 SPARE S - 20/1 B 20/1 - S SPARE 46 47 SPARE S - 20/1 C 2011 - S SPARE 48 49 SPARE S - 2011 A 20/1 - S SPARE 50 51 SPARE S - 20/1 B 20/1 - S SPARE 52 53 SPARE S - 20/1 C 20/1 - S SPARE 54 55 SPARE S - 20/1 A 100/3 - - 30.204 - P - - PANEL HR8A(VIA 75KVAXFMRT-8H) - 56 57 SPARE S - 20/1 B 58 59 SPARE S - 20/1 C 60 PHASE LOAD PHASE A= 61.84 KVA PHASE B= 57.67 KVA PHASE C= 53.49 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HP8 142.80 3.40 142.80 KVA 171.76 AMP PANEL HR8A 0.90 27.30 2.00 3 0.2 0 KVA 36.33 AMP CONN. LOAD 0.90 142.80 27.30 2.00 3.40 173.00 KVA 208.09 AMP CALC. LOAD 0.90 1 142.80 1 i 1 12.92 1 2.00 0.85 159.47 KVA 191.81 AMP PANEL HR8A LOCATION: ELEC RM 8TH FLR SERVING: HOTEL LOADS FED FROM: HP8 (VIA75 KVAXFMR T-8H) 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 225 AMP MAIN BREAKER AFC: 5,860 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 GUEST ROOM 805 HM 0.225 20/1 A 20/1 0.220 HM GUEST ROOM 802 2 3 GUEST ROOM 805 HM 0.225 20/1 B 20/1 0.220 HM GUEST ROOM 802 4 5 GUEST ROOM805 HM 0.225 2011 C 20/1 0.220 HM GUESTROOM802 6 7 GUEST ROOM 807 HM 0.221 2011 A 20/1 0.220 HM GU EST ROOM 804 8 9 GUEST ROOM 807 HM 0.221 20/1 B 20/1 0.220 HM GUEST ROOM 804 10 11 GUESTROOM807 HM 0.221 20/1 C 20/1 0.220 HM GUESTROOM804 1.2 13 GUESTROOM809 HM 0.223 2011 A 20/1 0.200 HM GUEST ROOM 806 14 15 GUESTROOM809 HM 0.223 20/1 B 20/1 0.200 HM GUESTROOM806 16 17 GUESTROOM809 HM 0.223 20/1 C 20/1 0.200 HM GUEST ROOM806 18 19 GUESTROOM811 HM 0.223 20/1 A 20/1 0.200 HM GUESTROOM808 20 21 GUESTROOM811 HM 0.223 20/1 B 20/1 0.200 HM GUESTROOM808 22 23 GUESTROOM811 HM 0.223 20/1 CI 20/1 0.200 HM GUESTROOM808 24 25 GUESTROOM813 HM 0.202 2011 A 20/1 0.200 HM GUESTROOM810 26 27 GUEST ROOM813 HM 0.202 2011 B 2011 0.200 HM GUESTROOM810 28 29 GUEST ROOM 813 HM 0.202 20/1 C 20/1 0.200 HM GUESTROOM810 30 31 GUEST ROOM815 HM 0.202 20/1 A 20/1 0.200 HM GUEST ROOM 812 32 33 GUEST ROOM 815 HM 0.202 20/1 B 20/1 0.200 HM GUEST ROOM 812 34 35 GUEST ROOM 815 HM 0.202 20/1 C 20/1 0.200 HM GUEST ROOM 812 36 37 GUEST ROOM817 HM 0.223 20/1 JA 1 20/1 0.200 HM GUEST ROOM 814 38 39 GUEST ROOM817 HM 0.223 20/1 B 20/1 0.200 HM GUESTROOM814 40 41 GUESTROOM817 HM 0.223 20/1 C 20/1 0.200 HM GUESTROOM814 42 43 GUESTROOM819 HM 0.223 20/1 A 2011 0.215 HM GUESTROOM816 44 45 GUESTROOM819 HM 0.223 20/1 B 20/1 0.215 HM GUESTROOM816 46 47 GUEST ROOM 819 HM 0.223 20/1 C 20/1 0.215 HM GUESTROOM816 48 49 GUEST ROOM821 HM 0.200 20/1 A 2011 0.257 HM GUESTROOM818 50 51 GUEST ROOM 821 HM 0.200 20/1 B 20/1 0.257 HM GUEST ROOM 818 52 53 GUESTROOM821 HM 0.200 20/1 C 20/1 0.257 HM GUESTROOM818 54 55 GUESTROOM823 HM 0.191 20/1 A 2011 0.180 R RCPT- ELEC RM 56 57 GUESTROOM823 HM 0.191 20/1' 20/1 - S SPARE 58 59 GUESTROOM823 HM 0.191 20/1 lid 20/1 - S SPARE 60 PHASE LOAD PHASE A= 10.84 KVA PHASE B= 10.07 KVA PHASE C= 9.29 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HR8A 0.18 12.14 12.32 KVA 34.18 AMP PANEL HR8B 0.72 15.17 2.00 17.89 KVA 49.65 AMP CONN. LOAD 0.90 27.30 2.00 30.20 KVA 83.84 AMP CALC. LOAD 0.90 12.92 1 2.00 1 1 15.82 KVA 43.92 AMP REQUIRED FEED-THRU LUGS OPTIONS: PANEL 1-111813 LOCATION: ELECRM 8TH FLR SERVING: HOTEL LOADS FED FROM: HR8A 208/120 VOLT 225 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 5,533 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 GUESTROOM905 HM 0.225 20/1 A 20/1 0.220 HM GUEST ROOM 902 2 3 GUEST ROOM 905 HM 0.225 20/1 B 20/1 0.220 HM GUEST ROOM 902 4 5 GUEST ROOM 905 HM 0.225 20/1 C 20/1 0.220 HM GUEST ROOM 902 6 7 GUEST ROOM 907 HM 0.221 20/1 A 20/1 0.220 HM GUEST ROOM 904 8 9 GUEST ROOM 907 HM 0.221 20/1 1 B I j 20/1 0.220 HM GUEST ROOM 904 10 11 GUEST ROOM 907 HM 0.221 20/1 C 20/1 0.220 HM GUEST ROOM 904 12 13 GUEST ROOM909 HM 0.223 20/1 A 2011 0.202 HM IGUESTROOM906 14 15 GUEST ROOM 909 HM 0.360 20/1 B 20/1 0.202 HM GUEST ROOM 906 16 17 GUEST ROOM909 HM 0.223 20/1 C 20/1 0.202 HM GUESTROOM906 18 19 GUEST ROOM 911 HM 0.223 20/1 A 20/1 0.202 HM GUESTROOM908 20 21 GUEST ROOM 911 HM 0.223 20/1 B 20/1 0.202 HM GUESTROOM908 22 23 GUEST ROOM 911 HM 0.223 2011 C 20/1 0.202 HM GUESTROOM908 24 25 GUEST ROOM 913 HM 0.221 20/1 A 20/1 0.200 HM GUESTTOOM910 26 27 GUEST ROOM 913 HM 0.221 20/1 B 2011 0.200 HM GU EST TOOM910 28 29 GUEST ROOM 913 HM 0.221 20/1 C 20/1 0.200 HM GUEST TOOM 910 30 31 GUEST ROOM 915 HM 0.221 20/1 A 20/1 0.200 HM GUEST ROOM 912 32 33 GUEST ROOM 915 HM 0.221 20/1 B 20/1 0.200 HM GUEST ROOM 912 34 35 GUEST ROOM 915 HM 0.221 20/1 C 20/1 0.200 HM GUEST ROOM 912 36 37 GUEST ROOM 917 HM 0.221 20/1 A 20/1 0.202 HM GUEST ROOM 914 38 39 GUEST ROOM 917 HM 0.221 20/1 B 2011 0.202 HM GUEST ROOM 914 40 41 GUEST ROOM 917 HM 0.221 20/1 C 20/1 0.202 HM GUEST ROOM 914 42 43 GUEST ROOM 919 HM 0.221 20/1 A 20/1 0.215 HM GUEST ROOM 916 44 45 GUEST ROOM 919 HM 0.221 20/1 B 20/1 0.215 HM GUESTROOM916 46 47 GUEST ROOM 919 HM 0.221 20/1 C 20/1 0.215 HM GUESTROOM916 48 49 GUESTROOM921 HM 0.221 20/1 A 20/1 0.257 HM GUEST ROOM918 50 51 GUEST ROOM 921 HM 0.221 20/1 B 20/1 0.257 HM GUEST ROOM 918 52 53 GUESTROOM921 HM 0.221 20/1 C 20/1 0.257 HM GUESTROOM918 54 55 GUEST ROOM 923 HM 0.191 20/1 A 20/1 - S SPARE 56 57 57 GUEST ROOM 923 GUEST ROOM 923 HM HM 0.191 0.191 20/1 20/1 -! B 2011 - S SPARE 58 59 GUEST ROOM 923 HM 0.191 20/1 C 20/1 - S SPARE 60 PHASE LOAD PHASE A= 6.61 KVA PHASE B= 6.03 KVA PHASE C= 5.25 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HR8B 12.46 12.46 KVA 34.57 AMP PANEL HR8C 0.72 2.71 2.00 SA3 KVA . 15.08 AMP CONN. LOAD 0.72 15.17 2.00 17.89 KVA 49.65 AMP CALC. LOAD 0.72 1 17.58 2.00 10.30 KVA 28.60 AMP REQUIRED FEED-THRU LUGS OPTIONS: PANEL HR6A LOCATION: ELEC RM 6TH FLR SERVING: HOTEL LOADS FED FROM: HP6 COA75 KVAXFMR T-6H) 208/120 VOLT 225 AMP 13US RATING SCCR: 10,000 A 3 PHASE 225 AMP MAIN BREAKER AFC: 5,877 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOADDESCRIPTION CKT 1 GUESTROOM605 HM 0.225 20/1 A 2011 0.220 HM GUESTROOM602 2 3 GUEST ROOM 605 HM 0.225 20/1 B 20/1 0.220 HM GUEST ROOM 602 4 5 GUEST ROOM 605 HM 0.225 20/1 C 2011 0.220 HM GUEST ROOM 602 6 7 GUESTROOM607 HM 0.221 20/1 A 20/1 0.220 HM GUESTROOM604 8 9 GUESTROOM607 HM 0.221 20/1 B 2011 0.220 HM GUESTROOM604 10 11 GUEST ROOM607 HM 0.221 2011 C 2011 0.220 HM GUESTROOM604 12 13 GUESTROOM609 HM 0.223 20/1 A 20/1 0.202 HM GUESTROOM606 14 15 GUESTROOM609 HM 0.223 20/1 B 20/1 0.202 HM GUESTROOM606 16 17 GUESTROOM609 HM 0.223 2011 C 20/1 0.202 HM GUESTROOM606 18 19 GUEST ROOM 611 HM 0.223 20/1 A 20/1 0.202 HM GUEST ROOM 608 20 21 GUEST ROOM611 HM 0.223 20/1 B 20/1 0.202 HM GUESTROOM608 22 23 GUEST ROOM 611 HM 0.223 20/1 C 20/1 0.202 HM GUEST ROOM 608 24 25 GUEST ROOM 613 HM 0.221 2011 A 20/1 0.200 HM GUEST ROOM 610 26 27 GUEST ROOM 613 HM 0.221 20/1 B 2011 0.200 HM GUEST ROOM 610 28 29 GUESTROOM613 HM 0.221 2011 C 20/1 0.200 HM GUEST ROOM610 30 31 GUEST ROOM 615 HM 0.223 20/1 A 20/1 0.200 HM GUEST ROOM 612 32 33 GUESTROOM615 HM 0.223 2011 B 20/1 0.200 HM GUESTROOM612 34 35 GUEST ROOM 615 HM 0.223 20/1 C 2011 0.200 HM GUEST ROOM 612 36 37 GUESTROOM617 HM 0.223 20/1 A 2011 0.202 HM GUESTROOM614 38 39 GUESTROOM617 HM 0.223 20/1 B 20/1 0.202 HM GUESTROOM614 40 41 GUESTROOM617 HM 0.223 20/1 C 20/1 0.202 HM GUEST ROOM 614 42 43 GUEST ROOM 619 HM 0.223 20/1 A 20/1 0.222 HM GUEST ROOM 616 44 45 GUEST ROOM 619 HM 0.223 20/1 B 20/1 0.222 HM GUEST ROOM 616 46 47 GUESTROOM619 HM 0.223 20/1 C 20/1 0.222 HM GUEST ROOM616 48 49 GUEST ROOM 621 HM 0.202 20/1 A 20/1 0.257 HM GUEST ROOM 618 50 51 GUEST ROOM 621 HM 0.202 2011 B 20/1 0.257 HM GUEST ROOM 618 52 53 GUESTROOM621 HM 0.202 20/1 C 20/1 0.257 HM GUESTROOM618 54 55 GUESTROOM623 HM 0.191 20/1 A 20/1 0.180 R RCPT -ELECRM 56 57 GUESTROOM623 HM 0.191 20/1 B 20/1 - S SPARE 58 59 GUESTROOM623 HM 0.191 20/1 EC 20l1 - S SPARE 60 PHASE LOAD PHASE A= 10.95 KVA PHASE B= 10.11 KVA PHASE C= 10.65 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HR6A 0.18 12.30 12.48 KVA 34.64 AMP PANEL HR6B 0.72 1.18 15.32 2.00 1.18 19.22 KVA 53.34 AMP CONN. LOAD 0.90 1.18 27.62 2.00 1.18 31.70 KVA 87.98 AMP CALC. LOAD 0.90 1.18 1 13.05 2.00 0.30 1 17.42 KVA 48.36 AMP REQUIRED FEED-THRU LUGS OPTIONS: PANEL HR6B LOCATION: ELEC RM 6TH FLR SERVING: HOTEL LOADS FED FROM: HR6A 208/120 VOLT 225 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 5,548 A 4 WIRE MOUNTING SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 GUEST ROOM 705 HM 0.225 2011 A 20/1 0.220 HM GUEST ROOM 702 2 3 GUEST ROOM 705 HM 0.225 20/1 B 2011 0.220 HM GUEST ROOM 702 4 5 GUEST ROOM 705 HM 0.225 20/1 C 2011 0.220 HM GUEST ROOM702 6 7 GUESTROOM707 HM 0.221 20/1 A 20/1 0.220 HM GUESTROOM704 8 9 GUEST ROOM 707 HM 0.221 20/1 B 20/1 0.220 HM GUEST ROOM704 10 11 GUEST ROOM 707 HM 0.221 20/1 C 2011 0,220 HM GUEST ROOM 704 12 13 GUEST ROOM 709 HM 0.223 20/1 A 20/1 0.202 HM GUEST ROOM 706 14 15 GUEST ROOM 709 HM 0.223 20/1 B 20/1 0.202 HM GUEST ROOM706 16 17 GUESTROOM709 HM 0.223 20/1 C 20/1 0.202 HM GUESTROOM706 18 19 GUEST ROOM 711 HM 0.223 20/1 A 20/1 0.202 HM GUEST ROOM708 20 21 GUEST ROOM 711 HM 0.223 20/1 B 20/1 0,202 HM GUEST ROOM708 22 23 GUEST ROOM 711 HM 0.223 20/1 C 2011 0.202 HM GUEST ROOM 708 24 25 GUEST ROOM713 HM 0.221 2011 A 20/1 0.200 HM GUESTROOM710 26 27 GUESTROOM713 HM 0.221 20/1 B 20/1 0.200 HM GUESTROOM710 28 29 GUEST ROOM 713 HM 0.221 20/1 C 20/1 0.200 HM GUESTROOM710 30 31. GUEST ROOM 715 HM 0.221 2011 A 20/1 0.200 HM GUEST ROOM712 32 33 GUESTROOM715 HM 0.221 20/1 B 20/1 0.200 HM GUESTROOM712 34 35 GUEST ROOM 715 HM 0.221 20/1 C 20/1 0.200 HM GUEST ROOM 712 36 37 GUEST ROOM 717 HM 0.221 20/1 A 20/1 0.202 HM GUEST ROOM 714 38 39 GUEST ROOM 717 HM 0.221 20/1 B 20/1 0.202 HM GUEST ROOM 714 40 41 GUEST ROOM 717 HM 0.221 20/1 C 20/1 0.202 HM GUEST ROOM 714 42 43 GUEST ROOM 719 HM 0.221 20/1 A 20/1 0.215 HM GUEST ROOM 715 44 45 GUEST ROOM 719 HM 0.221 20/1 B 20/1 0,215 HM GUEST ROOM 716 46 47 GUEST ROOM 719 HM 0.221 20/1 C 20/1 0.215 Hivl GUEST ROOM716 48 49 GUEST ROOM 721 HM 0.221 20/1 A 20/1 0.257 HM GUEST ROOM 718 50 51 GUEST ROOM 721 HM 0.221 20/1 B 20/1 0.257 HM GUEST ROOM718 52 53 GUEST ROOM 721 HM 0.221 20/1 C 2011 0.257 HM GUESTROOM718 54 55 GUEST ROOM 723 HM 0.191 20/1 A 20/1 - S SPARE 56 57 GUEST ROOM 723 HM 0.191 20/1 B 20/1 - S SPARE 58 59 GUEST ROOM 723 HM 0.191 2011 A-El 20/1 - S SPARE 60 PHASE LOAD PHASE A= 6.67 KVA PHASE B= 6.01 KVA PHASE C= 6.55 KVA LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS PANEL HR6B 12.32 12.32 KVA 34.19 AMP PANEL HR6C 0.72 1.18 3.00 2.00 1.18 6,90 KVA 19.15 AMP CONN. LOAD 0.72 1.18 15.32 2.00 1.18 19.22 KVA 53.34 AMP CALC, LOAD 0.72 1.18 7.66 2.00 0.30 1 11.85 KVA 32.90 AMP REQUIRED FEED-THRU LUGS OPTIONS: PANEL HR6C LOCATION: ELEC RM 6TH FLR SERVING: HOTEL LOADS FED FROM: HR613 208/120 VOLT 225 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 5,486 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 RCPT- HOUSEKEEPING 6TH FLR R 0.360 20/1 A 1 1 20/1 0.300 HM IGUESTROOM601 2 3 RCPT- ICE MAKER 6TH FLR D 1.000 *20/1 B 20/1 0,300. HM GUEST ROOM601 4 5 RCPT- HOUSEKEEPING 7TH FLR R 0.360 20/1 C 20/1 0.300 HM GUEST ROOM 601 6 7 RCPT- ICE MAKER 7TH FLR D 1.000 *20/1 A 20/1 0.300 HM GUEST ROOM601 8 9 SPARE S - 20/1 B 20/1 0.300 HM GUEST ROOM 701 10 11 SPARE S - 20/1 C 20/1 0.300 HM GUEST ROOM 701 12 13 SPARE S - 20/1 A 20/1 0.300 HM GUEST ROOM 701 14 15 SPARE S - 20/1 B 20/1 0.300 HM GUEST ROOM 703 16 17 SPARE S - 20/1 C 20/1 0,300 HM GUEST ROOM 703 18 19 SPARE S - 20/1 A 20/1 0.300 HM GUEST ROOM 703 20 21 SPARE S - 20/1 B 2011 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 2011 - S SPARE 26 27 SPARE S - 20/1 B 20/1 - S SPARE 28 29 SPARE S - 20/1 C 20/1 - S SPARE 30 31 SPARE S - 20/1 A 20/1 - S SPARE 32 33 SPARE S - 20/1 B 20/1 - S SPARE 34 35 SPARE S - 20/1 C 20/1 - S SPARE 36 37 SPARE S - 20/1 A 20/1 - S SPARE 38 39 SPARE S - 20/1 B 20/1 - S SPARE 40 41 SPARE S - 20/1 C 2011 - S SPARE 42 43 SPARE S - 20/1 A 20/1 - S SPARE 44 45 SPARE S - 20/1 B 20/1 - S SPARE b<z 46 47 SPARE S - 20/1 C 20/1 - S SP 48 49 SPARE S - 20/1 A 20/1 - S SP _ NEC 50 51 SPARE S - 20/1 B 20/1 - S SP E 152 53 SPARE S - 20/1 C 20/1 - S SP E 54 55 SPARE S - 20/1 A 2011 - S SP E 56 57 SPARE S - 20/1 B 2011 - S SP E 58 59 RCP-2 (RECIRC. PUMP) (LEVEL 6) M 1.180 20/1 C 20/1 - S SP E 0 T 11a 60 PHASE LOAD PHASE A= 2.56 KVA PHASE B= 1.90 KVA PHASE C= 2.44 KVA -- LOAD TYPE L R M H WH HM D A K LM TOTAL LOADS CONN. LOAD 0.72 1.18 3.00 2.00 1.18 6.90 KVA 19.15 AMP CALC. LOAD 0.72 1.18 1.50 2.00 0.30 5.70 KVA 15.81 AMP NOTES: * = GFCI CIRCUIT BREAKER. DECEIVED CITY OF TUKWILA OCT 15 2015 PERMIT CENT. EP PANEL SCHEDULE INDEX PANEL NAME PANEL NAME PANEL NAME HR8C HP8 HR6A HP10 HR8A HR6B HR10A HR8B HR6C ISSUE A Date Description 10/07/15 ELECTRICAL PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB AN PHASE ELECTRICAL PERMIT PROJECT NUMBER AN . PROJECT ry W 3: Ow F Y z d w w� 03: V Q I- z 04 N T� N t1 V , JLTANT 'TRATION SlohAy E�'f � 7/15 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 8264446 SHEET TITLE AND NUMBER ELECTRICAL PANEL SCHEDULES E8.07 j i 1 r 1 rn 3 cn Li J D 0 W U) PANEL HP19 LOCATION: ELEC RM (LEVEL 19 ROOF) SERVING: HOTEL LOADS (1-PHASE) FED FROM: METER CENTER (MC-18) 208/120 VOLT 200 AMP MAIN LUGS ONLY SCCR: 10,000 A 1 PHASE AFC: 7,543 A 3 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA AJP PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 RCPT - MEN'S RR 1908 R 0.180 20/1 A 20/1 0.100 M LOUVER (L-5 19TH FLR DHW RM 2 3 RCPT - WOMEN'S RR 1909 R 0.180 20/1 B 20/1 0.720 R RCPT - RM 4021, 1911 4 5 RCPT - RM 1911 MICROWAVE R 1.200 20/1 A 20/1 0.720 R RCPT - RM 4021, 1911 6 7 RCPT- RM 1911 FRIDGE R 1.500 20/1 B 20/1 0.720 R RCPT- RM4021, 1911 8 9 RCPT- RM 1911 COFFEE R 1.800 2011 A 20/1 0.540 R RCPT- STOR. 1912, DOMES. HW 1913 10 11 RANGE RM 1911 - A - 8.000 - 50/2 - B 20/1 0.540 R RCPT- STOR. 1912, DOMES. HW 1913 12 13 A 20/1 0.360 R RCPT-ROOF MECH EQPT 14 15 RCPT - RM 1911 HOT HOLD R 1.800 20/1 B 20/1 1.800 R RCPT - RM 1907 COFFEE 16 17 RCPT - RM 1911 HOT HOLD R 1.800 20/1 A 20/1 - S SPARE 18 19 RCPT- RM 1911 COLD HOLD R 1.800 20/1 B 20/1 - S SPARE 20 21 SPARE S - 40/1 A 20/1 - S SPARE 22 23 SPARE S - 40/1 B 20/1 - S SPARE 24 25 SPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 20/1 B 20/1 - S SPARE 28 29 SPARE S - 20/1 A 20/1 - S SPARE 30 31 SPARE S - 20/1 B 20/1 - S SPARE 32 33 SPARE S - 20/1 A 20/1 1.093 L LTG -19TH FLR SKYCLUB 34 35 SPARE S - 20/1 B 20/1 1.771 L LTG - 19TH FLR SKYCLUB 36 37 SPARE S - 20/1 A 20/1 0.811 L LTG -19TH FLR SKYCLUB SERVICE 38 39 DWH 1 (WTR HTR) (LEVEL 19) WH 3.300 40/1 B 20/1 1.772 L LTG - 19TH FLR LBY, MTG, RRs 40 41 DWH 1 (WTR HTR) (LEVEL 19) WH 3.300 40/1 A 2011 0.915 L LTG -19TH FLR STORAGE, DOM. HW 42 PHASE LOAD PHASE A= 16.82 KVA PHASE B= 19.90 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 6.36 15.66 0.10 6.60 8.00 0.10 36.72 KVA 176.55 AMP CALC. LOAD 7.95 12.83 0.10 6.60 8.00 0.03 35.51 KVA 170.71 AMP PANEL HR1 OB LOCATION: ELEC RM 10TH FLR SERVING: HOTEL LOADS FEDFROM: HR10A 208/120 VOLT 225 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 5,562 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 GUEST ROOM 1105 HM 0.225 20/1 A 1 20/1 0.220 HM GUEST ROOM 1102 2 3 GUEST ROOM 1105 HM 0.225 20/1 B 20/1 0.220 HM GUEST ROOM 1102 4 5 GUEST ROOM 1105 HM 0225 20/1 C 20/1 0.220 HM GUEST ROOM 1102 6 7 GUEST ROOM 1107 HM 0.221 20/1 A 2011 0.220 HM GUEST ROOM 1104 8 9 GUEST ROOM 1107 HM 0.221 20/1 B 20/1 0.220 HM GUEST ROOM 1104 10 11 GUEST ROOM 1107 HM 0.221 20/1 C 2011 0.220 HM GUEST ROOM 1104 12 13 GUEST ROOM 1109 HM 0.223 20/1 A 2011 0.202 HM GUEST ROOM 1106 14 15 GUEST ROOM 1109 HM 0.223 20/1 B 20/1 0.202 HM GUEST ROOM 1106 16 17 GUEST ROOM 1109 HM 0.223 20/1 C 20/1 0.202 HM GUEST ROOM 1106 18 19 GUEST ROOM 1111 HM 0.223 20/1 A 20/1 0.202 HM GUEST ROOM 1108 20 21 GUEST ROOM 1111 HM 0.223 20/1 B 20/1 0.202 HM GUEST ROOM 1108 22 23 GUEST ROOM 1111 HM 0.223 20/1 C 20/1 0.202 HM GUEST ROOM 1108 24 25 GUEST ROOM 1113 HM 0.221 20/1 A 20/1 0.200 HM GUEST ROOM 1110 26 27 GUEST ROOM 1113 HM 0.221 20/1 B 20/1 0.200 HM GUEST ROOM 1110 28 29 GUEST ROOM 1113 HM 0.221 20/1 C 20/1 0.200 HM GUEST ROOM 1110 30 31 GUEST ROOM 1115 HM 0.221 20/1 A 20/1 0.200 HM GUEST ROOM 1112 32 33 GUEST ROOM 1115 HM 0.221 20/1 B 20/1 0.200 HM GUEST ROOM 1112 34 35 GUEST ROOM 1115 HM 0.221 20/1 C 20/1 0.200 HM GUEST ROOM 1112 36 37 GUEST ROOM 1117 HM 0,221 20/1 A 20/1 0.202 HM GUEST ROOM 1114 38 39 GUEST ROOM 1117 HM 0.221 20/1 B 20/1 0.202 HM GUEST ROOM 1114 40 41 GUEST ROOM 1117 HM 0.221 20/1 C 20/1 0.202 HM GUEST ROOM 1114 42 43 GUEST ROOM 1119 HM 0.221 20/1 A 20/1 0.215 HM GUEST ROOM 1116 44 45 GUEST ROOM 1119 HM 0.221 20/1 B 20/1 0.215 HM GUEST ROOM 1116 46 47 GUEST ROOM 1119 HM 0.221 20/1 C 20/1 0.215 HM GUEST ROOM 1116 48 49 GUEST ROOM 1121 HM 0.221 20/1 A 2011 0.257 HM GUEST ROOM 1118 50 51 GUEST ROOM 1121 HM 0.221 20/1 B 20/1 0.257 HM GUEST ROOM 1118 52 53 GUEST ROOM 1121 HM 0.221 20/1 C 20/1 0.257 HM GUEST ROOM 1118 54 55 GUEST ROOM 1123 HM 0.191 20/1 A 20/1 - S SPARE 56 57 GUEST ROOM 1123 HM 0.191 20/1 B 20/1 - S SPARE 58 59 GUEST ROOM 1123 HM 0.191 20/1 C 20/1 - S SPARE 60 PHASE LOAD PHASE A= 6.62 KVA PHASE B= 5,89 KVA PHASE C= 6.43 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS PANEL HR10B 12.32 12.32 KVA 34.19 AMP PANEL HR10C 0.72 1.18 2.72 2.00 1.18 6.62 KVA 18.37 AMP CONN. LOAD 0.72 1.18 15.04 2.00 1.18 18.94 KVA 52.56 AMP CALC. LOAD 0.72 1.18 7.52 2.00 0.30 11.71 KVA 32.51 AMP REQUIRED FEED-THRU LUGS OPTIONS: PANEL HR1 OC LOCATION: ELEC RM 10TH FLR SERVING: HOTEL LOADS FEDFROM: HR10B 208/120 VOLT 225 AMP MAIN LUGS ONLY SCCR: 10,000 A 3 PHASE AFC: 5,500 A 4 WIRE MOUNTING: SURFACE CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 RCPT- HOUSEKEEPING 10TH FLR R 0.360 20/1 A 20/1 0.365 HM GUEST ROOM 1001 2 3 RCPT- ICE MAKER 10TH FLR D 1.000 *20/1 B 20/1 0.365 HM GUEST ROOM 1001 4 5 RCPT- HOUSEKEEPING 11TH FLR R 0.360 20/1 C 20/1 0.365 HM GUEST ROOM 1001 6 7 RCPT- ICE MAKER 11TH FLR D 1.000 "20/l A 20/1 0.365 HM GUEST ROOM 1001 8 9 SPARE S - 20/1 B 2011 0.202 HM GUEST ROOM 1103 10 11 SPARE S - 20/1 C 20/1 0.202 HM GUEST ROOM 1103 12 13 SPARE S - 20/1 A 20/1 0.202 HM GUEST ROOM 1103 14 15 SPARE S - 20/1 B 20/1 0.217 HM GUEST ROOM 1101 16 17 SPARE S - 20/1 C 20/1 0.217 HM GUEST ROOM 1101 18 19 SPARE s - 20/1 A 20/1 0.217 HM GUEST ROOM 1101 20 21 SPARE S - 20/1 B 20/1 - S SPARE 22 23 SPARE S - 20/1 C 20/1 - S SPARE 24 25 SPARE S - 20/1 A 20/1 - S SPARE 26 27 SPARE S - 20/1 B 20/1 - S SPARE 28 29 SPARE S - 20/1 C 20/1 - S SPARE 30 31 SPARE S - 20/1 A 20/1 - S SPARE 32 33 SPARE S - 20/1 B 20/1 - S SPARE 34 35 SPARE S - 20/1 C 20/1 - S SPARE 36 37 SPARE S - 20/1 A 20/1 - S SPARE 38 39 SPARE S - 20/1 B 20/1 - S SPARE 40 41 SPARE S - 20/1 C 20/1 - S SPARE 42 43 SPARE S - 20/1 A 20/1 - S SPARE 44 45 SPARE S - 20/1 B 20/1 - S SPARE 46 47 SPARE S - 2011 C 20/1 - S SPARE 48 49 SPARE S - 20/1 A 20/1 - S SPARE 50 51 SPARE S - 20/1 B 20/1 - S SPARE 52 53 SPARE S - 20/1 C 20/1 - S SPARE 54 55 SPARE S - 20/1 A 20/1 - S SPARE 56 57 SPARE S - 20/1 B 20/1 - S SPARE 58 59 RCP-3 (RECIRC. PUMP) (LEVEL 11) M 1.180 20/1 C 2011 - S SPARE 60 PHASE LOAD PHASE A= 2.51 KVA PHASE B= 1.78 KVA PHASE C= 2.32 KVA LOAD TYPE L R M H WH HM D A K LM TOTALLOADS CONN. LOAD 0.72 1.18 2.72 2.00 1.18 6.62 KVA 18.37 AMP CALC. LOAD 0.72 1.18 1.36 2.00 0.30 5.55 KVA 15.41 AMP NOTES: = GFCI CIRCUIT BREAKER. 1EVIEWED F0; ► PLIANCE WiT -- NFPA 70 - NFL ur-L 0 3 7015 i amity of Tukwila LDlNGDIVIStrt RECEIVED CITY OF TUKWILA OCT 1 5 2015 PERMIT CENTER PANEL SCHEDULE INDEX PANEL NAME PANEL NAME PANEL NAME - HP19 HR10B - - HR10C ISSUE A Date Description 10/07/15 ELECTRICAL. PERMIT ISSUE SCALE: CHECKED BY: CHL APPROVED BY: DRAWN BY: JAB KEYPLAN i i i } i �t PHASE ELECTRICAL PERMIT PROJECT NUMBER GWA NO. PROJECT ry W 3: o Lu F Y a3: o wQ W� F- fp Y V Q i- z M N N V i JLTANT 'TRATION 5 GROUP WEST ARCHITECTS, INC., P.S. 3601 FREMONT AVE. N. SUITE 31 SEATTLE, WA 98103 PHONE: (206) 826-4447 FAX: (206) 8264446 SHEET TITLE AND NUMBER ELECTRICAL PANEL SCHEDULES E8.08