Loading...
HomeMy WebLinkAboutPermit EL15-1018 - TWIN PEAKS - ELECTRICAL SYSTEMS AND FEEDER INSPECTION'TWIN PEAKS 17920 SOUTHCENTER PKWY EL15-1018 City of Tukwila • Department of Community Development `� ,� • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 3523049123 Permit Number: EL15-1018 Address: 17920 SOUTHCENTER PKWY Issue Date: 4/5/2016 Permit Expires On: 2/6/2017 Project Name: TWIN PEAKS Owner: Name: MADISON INVESTMENTS LLC Address: P 0 BOX 1922, BOZEMAN, CO, 59771 Contact Person: Name: ALEX KANAPILLY Address: 3333 S BANNOCK ST, STE 340, ENGLEWOOD, CO, 80110 Contractor: Name: STERLING ELECTRICAL CONTRACTOR Address: 6125 20TH ST SW, LYNNWOOD, WA, 98036 License No: STERLEC859MS Lender: Name: Address: Phone: (303) 886-6219 Phone: (425) 774-1903 Expiration Date: 7/16/2017 DESCRIPTION OF WORK: ELECTRICAL SYSTEMS ASSOCIATED WITH THE CONSTRUCTION OF NEW RESTAURANT VISION.#1 ;,ADDING A FEEDER INSPECTION FOR A TEMPORARY GENERATOR. Valuation of single family: $0.00 Fees Collected: $2,611.54 Valuation of mf/comm: $125,000.00 Type of Work: NEW Electrical Service Provided by: PUGEST SOUND ENERGY Water District: HIGHLINE Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: Dater �P I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and a e to th c di ' ns attached to this permit. Signature: ` Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB 7001 UNDERGROUND/SLAB City of Tukwila Department of Community Development * 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 3523049123 Permit Number: EL15-1018 Address: 17920 SOUTHCENTER PKWY Issue Date: 4/5/2016 Permit Expires On: 10/2/2016 Project Name: TWIN PEAKS Owner: Name: MADISON INVESTMENTS LLC Address: P 0 BOX 1922, BOZEMAN, CO, 59771 Contact Person: Name: ALEX KANAPILLY Phone: (303) 886-6219 Address: 3333 S BANNOCK ST, STE 340, ENGLEWOOD, CO, 80110 Contractor: Name: STERLING ELECTRICAL CONTRACTOR Phone: (425) 774-1903 Address: 6125 20TH ST SW, LYNNWOOD, WA, 98036 License No: STERLEC859MS Expiration Date: 7/16/2017 Lender: Name: Address: DESCRIPTION OF WORK: ELECTRICAL SYSTEMS ASSOCIATED WITH THE CONSTRUCTION OF NEW RESTAURANT Valuation of single family: $0.00 Fees Collected: $2,530.64 Valuation of mf/comm: $125,000.00 Type of Work: NEW Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-468: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature:---L����il/��C.P Date:LrrJS I hearby certify that I have read. and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: A t , ' Date: l U Print Name: S `U V This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKW. . Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. rz L S Project No. ll Date Application Accepted: Date Application Expires: -a Q For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION I King Co Assessor's Tax No.. 352304-9123 Site Address: 17920 Southcenter Pkwy Suite Number: Floor: Tenant Name: Twin Peaks - Tukwila New Tenant: ®.....Yes [-]..No PROPERTY OWNER Name: Stovetop Restaurant Group Address: 9327 Piperhill Drive SE City: Olympia State: WA Zip: 98513 CONTACT PERSON — person receiving all project communication Name: Alex Kanapilly Address: 3333 S. Bannock Street Suite 340 City: Englewood State: CO Zip: 80110 Phone: Q03) 886-6219 Fax: Email: Valuation of Project (contractor's bid price): $ t I S" , O b O ELECTRICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Scope of Work (please provide detailed information): Electrical systems associated with the construction of a new Twin Peaks Restaurant of 6929 sf with a 1,399 sf patio. Will service be altered? ❑ Yes Type of Use: Restaurant m No Adding more than 50 amps? ❑ Yes m No Type of work: m New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: EZ Puget Sound Energy ❑ Seattle City Light H:\Applications\Foms-Applications On Line\2014 ApplicationsTlectrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings...................................$152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits.................$81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 11/20/2015 Print Name: Brad Clawson Day Telephone: (303) 501-9272 Mailing Address: 9327 Piperhill Drive SE Olympia, WA 98513 City State Zip H:\Applications\Forms-Applications On Line\2014 Applications0ectrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page 2 of 2 r'ERNfiIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-1018 DATE: 11/24/15 PROJECT NAME: TWIN PEAKS SITE ADDRESS: 17920 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 35 AWC lajS-I s Building Division n Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 11/24/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved 0 Corrections Required (corrections entered in Reviews) Notation: DUE DATE: 12/22/15 Approved with Conditions W Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southeenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: _ _ ZO 1G Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # --F-- after Permit is Issued �❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: / %/I %i fetal kS Project Address: / 7 9 Z© Contact Person:4rori arg1/C c Phone Number: G/Z5 r 77L� Summary of Revision: `ac T6 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ❑ Entered in TRAKiT on W:\Permit CenteATemplates7orms\Revision Submittal Form. doc Revised: August 2015 OFF HOURS INSPECTION Reimbursement authorization/approval to conduct inspection activities during off hours. Date: Z>I / I Permit Number: EUS_ — it) is Requested By: Firm/Company: Inspection Information Project Name: Lo. ,J Q�ftj_s� Project Address/Location: 119 �� < t - fZ P"\1 , l (,t(G(,ljlt�i4 Requested Date for Inspection: � Requested Time: )PM Contact Name: ��S� (SL� 11L,� Phone Number: Special Conditions for Consideration: i�19U431L � (�� 0f ` ** Contractor will be charged a minimum for three (3) hour inspection time for any off -hours inspection work at $100.00 per hour (minimum total of $300.00). This is to be paid at the time of request. ** The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate invoice will be issued for all inspection time in excess of three (3) hours. RECEIVE'' CITY 11 TU 1VV l 1.. a' Signature: Date: Printed Name: AUG3 WIS PERMIT CENT City Use Only: �} (� Approved: Disapproved: Paid: '`'' $00 Receipt No: b � 2 b Date of Approval/Disapproval: Remarks: Authorized Reviewer: W:\Permit Center\Templates\Forms\off hours inspection 1-2015.docx Revised: January 1, 2015 k _ l r Date Paid: Tuesday, August 23, 2016 Paid By: VISION BUILDERS GROUP Pay Method: CREDIT CARD 622720 Printed: Tuesday, August 23, 2016 4:02 PM 1 of 1 0r;? SYSTEMS Date Paid: Tuesday, August 23, 2016 Paid By: CHRIS GERBER Pay Method: CREDIT CARD 529707 Printed: Tuesday, August 23, 2016 8:29 AM 1 of 1 LJ L1 "fSYSTEMs DESCRIPTIONS QUANTITY PermitTRAK PAID $2,043.98 EL15-1018 Address: 17920 SOUTHCENTER PKWY Apn: 3523049123 $2,043.98 ELECTRICAL $1,946.65 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,946.65 TECHNOLOGY FEE $97.33 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: .. $97.33 $2,043.98 Date Paid: Tuesday, April 05, 2016 Paid By: VISION BUILDERS GROUP LLC Pay Method: CHECK 2257 Printed: Tuesday, April 05, 2016 9:38 AM 1 of 1 (rITTAII SYSTEMS DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $8,038.96 D15-0293 Address: 17920 SOUTHCENTER PKWY Apn: 3523049123 $6,957.06 DEVELOPMENT $6,707.06 PLAN CHECK FEE R000.345.830.00.00 0.00 $6,707.06 PUBLIC WORKS $250.00 BASE APPLICATION FEE R000.322.100.00.00 0.00 $250.00 EL15-1018 Address: 17920 SOUTHCENTER PKWY Apn: 3523049123 $486.66 ELECTRICAL $486.66 PLAN CHECK FEE R000.345.832.00.00 0.00 $486.66 M15-0156 Address: 17920 SOUTHCENTER PKWY Apn: 3523049123 $346.43 MECHANICAL $346.43 PLAN CHECK FEE R000.322.102.00.00 0.00 $346.43 PG15-0136 Address: 17920 SOUTHCENTER PKWY Apn: 3523049123 $248.81 GAS $83.88 PLAN CHECK FEE R000.322.103.00.00 0.00 $83.88 PLUMBING $164.93 PLAN CHECK FEE R000.322.103.00.00 TOTAL FEES PAID BY RECEIPT: R6698 0.00 $164.93 $8,038.96 Date Paid: Friday, November 20, 2015 Paid By: JB CLAWSON Pay Method: CREDIT CARD 04897D Printed: Friday, November 20, 2015 2:38 PM 1 of 1 CRSYSTEMS r INSPECTION RECORD yr- Retain a copy with permit( INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: , Date Called: Special Instru ions: Date Wanted: a Requester: Phone No: u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit` �C� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 + Project: r�V6� Type of Inspection: Address: `�` Date Called: Special Instr tions: Date Wanted: a.m Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: �- 2, 64 (Lvt't5 ON">c�, t- t a Ak -S'kjv i LLO a I kF U> r' f5, 5rOd- A(C F -I&ff5C G6 6J �o-& LAA6�jD c-c- T— P 051 1 �1 O-LAI1 g.CtZ4. D PO �((6 L�k4l LIP E+�5 � �� ` � r � �1JI� r✓ I � E U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 4( INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �^ K Type of Inspection: / Address: Date Called: Special Instr ctions: Date Wanted: a.m. Tb Requester: Phone No: ElApproved per applicable codes. F�- Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. O INSPECTION RECORD Retain a copy with permit 16)5--, ' o/y INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: uiId F Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: a.m .m. Requester: Phone No: 3� a 11121 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must b6 paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit G INSPE TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: F FTy t i p� a of �' nspecti `� va,cif,br t Address:/RLo l S.C. fl, Date Called: Special Instructions: - 2 ` o r� Date Wanted: a. .m. Requester: Phone No: 3 73 U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I 'y 7INSPECTION RECORD C,�+ INSPECTION N0. PEJ Retain a copy with permit PE RMMI `a Q T NO. CITY OF TUKWILA BUILDING DIVISION 1P 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Project:. TWA Type of Inspection: Address: � � Date Called: Special Instru tions: Date Wanted: I V a.m. Requester: Phone No: -30 5-36 ❑ Approved per applicable codes. Corrections required prior to approval. '—' paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: INSPECTION RECORD7 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: tit. Type of Inspection: Q JAJ Address: os-�_- Date Called: Special Instructions: Date Wanted: a.m p.m. Requester: Phone No: 11 Approved per applicable codes. 11 Corrections required prior to approval. " paid at 6300 Southcenter Blvd.. Suite 100. Calt to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: P Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: Approved per applicable codes. 11 Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD ,( Retain a copy with permit W�f ��✓r INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: et ( Type of Inspection: i Address: � �� CO Date Called: Special Instructions: / ,®o Date Wanted: a 7111 pm n Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: SAT (I-oo rJj Inspector: I Date: 0 7 T1 REINSPECTION FEE REQUIRED. Prior to next inspection: fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD �'vl ��rb Retain a copy with permit d INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: f��f A/ Type of Inspection: Address: IZIZ.0 Date Called: Special Instructions: Date Wanted: a. p.m. lZy Requester: Phone No: Z-� % a Approved per applicable codes. L_..! Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit' INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �rv Type of lnspeption: Address: *D ,5 O Date Called:/ Special Instructions: Date Wanted: a Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: i U Inspector: r Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must b? paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORDG f Retain a copy with permit lam[ � INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: f �� A g . 1�/�- Type of Inspection* �i�ction: Address: Date Called: Special Instructions: Date Wanted: a. .m. Requester: Phone No: Approved per applicable codes. L_J Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD / 1 Retain a copy with permit 1� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � � Type of ins�ec Address: Z? Date Called: Special Instru tions: .via f o l a. Date Wanted: 106 Requester: Phone No: ----------------- ❑ Approved per applicable codes. Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Sterling Electrical Contractor Home Safety & Health Washington State Department of Labor ,,& Industries Sterling Electrical Contractor Espar'ioI Contact Claims & Insurance Owner or tradesperson 6126 200th St SW LYNNWOOD, WA 98036 Principals 425-774-1903 Graves, Aaron M, PARTNER/MEMBER SNOHOMISH County Graves, Jessica L, PARTNER/MEMBER Graves, Aaron M, AGENT Doing business as Sterling Electrical Contractor WA UBI No. Business type 603 513 444 Limited Liability Company Parent company Governing persons Vision Builders Group LLC AARON MICHAEL GRAVES JESSICA LIANE GRAVES; License Page 1 of 2 Search L&I A-'7.. I m Workplace Rights Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ............................................................... Meets current requirements. License specialties GENERAL License no. STERLEC859MS Effective — expiration 07/16/2015— 07116/2017 Designated administrator ...... ............ Graves, Aaron License type Electrical Administrator Active. Meets current requirements. License no. GRAVEA"913JH https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603513444&LIC=STERLEC859MS&SAW= 04/05/2016 Ak COMcheck Software Version 4.0.1 Interior Lighting Compliance.Certificate Project Information Energy Code: 2012 IECC Project Title: Twin Peaks Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: 17920 S. Center Parkway John Tinsley Tukwila, WA 98188 kVA Consulting 38140 Fawn Meadows Trail Additional Efficiency Package Elizabeth, CO 80107 303.646.4770 john@kvaconsulting.net Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Wafts / ft2 (B X C) 1-Dining: bar lounge/leisure 6925 0.99 6856 Total Allowed Watts = 6856 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. 1-Dinina: bar lounge/leisure LED 1: LF-01: Downlight: LED PAR 7W: 1 43 7 301 LED 1 copy 1: LF-01 C: Downlight: Other: 1 14 9 126 LED 1 copy 2: LF-02: Monopoint Track Head: Other: 1 66 9 594 Track lighting 1: LF-02: Track Lighting: Wattage based on current limiting device capacity 0 0 0 120 LED 3: LF-03: Moose Antler Pendant: Other: 1 1 240 240 Incandescent 1: LF-05: Elk Antler Pendant: Incandescent 20W: 6 5 120 600 LED 3 copy 1: LF-07: Bear Sconce: LED PAR 18W: 1 5 18 90 Track lighting 1 copy 1: LF-08: Spot Track: Wattage based on current limiting device capacity 0 0 0 120 Linear Fluorescent 1: LF-13: 2x4 Flourescent: 46" T5 28W: Electronic: 2 17 56 952 Incandescent 2 copy 1: LF-20: Vanity: Incandescent 60W: 6 1 360 360 LED 5: LF-L: LED Rope Light .77w/f: Other: 1 1 59 59 Total Proposed Watts 3562 Interior Lighting Compliance Statement Compliance. Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.1 and to comply with the mandatory requirements listed in the Inspection Checklist. Project Title: Twin Peaks Report date: 11/16/15 Data filename: \\KVAFS2013\Public\2015\2015-120\Admin\Schedules\Twin Peaks Comcheck.cck Page 1 of 7 Name - Title Signature Date Project Title: Twin Peaks Report date: 11/16/15 Data filename: \\KVAFS2013\Public\2015\2015-120\Admin\Schedules\Twin Peaks Comcheck.cck Page 2 of 7 13 GENERAL PROJECT NOTES NOTE: SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL CONSTRUCTION REQUIREMENTS 1. THE CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A COMPLETE, OPERATIONAL AND PROPERLY FUNCTIONING ELECTRICAL SYSTEM 2. MATERIALS AND INSTALLATION SHALL COMPLY WITH CODES, LAWS AND ORDINANCES OF FEDERAL, STATE AND LOCAL GOVERNING BODIES HAVING JURISDICTION. 3. MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY U.L., ETL, CSA OR ANOTHER RECOGNIZED TESTING LAB. ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. SHALL BE NEW, UNLESS SPECIFICALLY INDICATED AS EXISTING TO BE REUSED. 4. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO GOVERNMENTAL AGENCIES AND UTILITY COMPANIES SHOP DRAWINGS REQUIRED BY THESE AGENCIES FOR APPROVAL. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, GOVERNMENTAL FEES, TAXES AND LICENSES NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE ELECTRICAL WORK. THIS CONTRACTOR SHALL SECURE AND PAY ALL FEES AND PERMITS PERTAINING TO THIS CONTRACT, SHALL BE RESPONSIBLE FOR WORKER'S IDENTIFICATION AND BADGING, SAFETY, AND LIABILITY INSURANCE. PROVIDE BARRICADES, WARNING SIGNS, AND TRASH REMOVAL FOR THE SAFETY OF THE WORKERS UNDER THIS CONTRACTOR'S EMPLOY. 5. THE CONTRACTOR SHALL NOTIFY.THE ARCHITECT/ENGINEER/OWNER OF ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN VIOLATION OF LAWS, ORDINANCES, RULES OR REGULATIONS OF AUTHORITIES HAVING JURISDICTION. 6. THE CONTRACTOR SHALL PREPARE THE DOCUMENTS, INCLUDING DRAWINGS, REQUIRED TO OBTAIN . APPROVAL OF THE EQUIPMENT AND LOCATIONS OF THE DEVICES THAT COMPRISE THE BUILDING FIRE ALARM LIFE SAFETY SYSTEM. THE DRAWINGS AND CUT SHEETS SHALL BE PROVIDED TO A PROFESSIONAL ENGINEER FOR REVIEW AND APPROVAL. THE APPROVED DRAWINGS WILL BE STAMPED, SIGNED AND RETURNED TO E.C. TO SUBMIT TO THE BUILDING DEPARTMENT. 7. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE, AND THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS, LOCAL JURISDICTIONAL CODES AND REQUIREMENTS, AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO DO SO WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE CONTRACT. SUBMISSION OF PROPOSAL IN CONNECTION WITH THIS WORK SHALL IMPLY THAT THE BIDDER HAS EXAMINED THE JOB SITE. NO EXTRA CHARGE WILL BE ALLOWED FOR CHANGES AS A RESULT FROM FAILURE TO EXAMINE THE JOB SITE. 8. THE CONTRACTOR SHALL PROVIDE TEMPORARY POWER AND WIRING FOR THE PERFORMANCE OF ALL TRADES, FOR THE ENTIRE PERIOD OF CONSTRUCTION AND SHALL REMOVE ALL TEMPORARY WIRING AT THE COMPLETION OF CONSTRUCTION. 9. THE EXISTING POWER, SIGNAL AND COMMUNICATION SYSTEMS ARE TO REMAIN IN SERVICE TO PROVIDE FOR THE OWNER'S FUNCTION. SHOULD IT BECOME NECESSARY TO SHUT -DOWN ANY SYSTEM OR PORTION OF A SYSTEM, APPROVAL IN WRITING MUST BE OBTAINED FROM THE OWNER AND SHALL ONLY APPLY FOR THE PERIOD AND TIME AGREED UPON. THE BID IS TO INCLUDE THE COST OF ANY TEMPORARY WIRING AND PREMIUM TIME REQUIRED FOR THE SHUTDOWN. 10. ALL MATERIALS AND EQUIPMENT SHALL BE ERECTED, INSTALLED, CONNECTED, CLEANED, ADJUSTED, TESTED, CONDITIONED, AND PLACED IN SERVICE IN ACCORDANCE WITH THE MANUFACTURER'S DIRECTIONS AND RECOMMENDATIONS. 11. ALL CUTTING, DRILLING AND PATCHING OF MASONRY, STEEL OR IRON WORK BELONGING TO THE BUILDING MUST BE DONE BY THIS CONTRACTOR IN ORDER THAT HIS WORK MAY BE PROPERLY INSTALLED, BUT UNDER NO CONDITIONS MAY STRUCTURAL WORK BE CUT, EXCEPT AT THE DIRECTION OF THE ARCHITECT -DESIGNER OR THEIR REPRESENTATIVE. 12. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ELECTRICAL FIXTURES AND ELECTRICAL DEVICES. MOUNTING HEIGHTS SHALL CONFORM TO ADA/ICC/ANSI STANDARDS. 13. ALL WORK REQUIRED FOR THE INSTALLATION AS SHOWN ON DRAWINGS INCLUDING LABOR, EQUIPMENT AND MATERIALS SHALL BE IN STRICT COMPLIANCE WITH THE BUILDING STANDARDS. 14. PROVIDE COMPLETE METAL RACEWAY SYSTEMS AND ENCLOSURES FOR ALL WIRING THROUGHOUT THE EXTENT OF THE REQUIRED SYSTEM. 15. ALL TELE/ DATA BOXES SHALL BE PROVIDED WITH A 1 /2" CONDUIT AND BUSHING WITH PULL STRING RUN 6" ABOVE FINISHED CEILING OR CEILING GRID. ELECTRICAL METALLIC TUBING (EMT) SHALL BE USED FOR ALL WALL OUTLETS & TELEPHONE WIRING RUNNING BELOW RAISED FLOOR OR ABOVE HARD CEILINGS. 16. ALL RECEPTACLES NOTED AS ISOLATED GROUND (IG) OR DEDICATED OR CIRCUITED AS DEDICATED SHALL BE PROVIDED WITH A DEDICATED GROUND AND NEUTRAL. ALL RECEPTACLES IN BATHROOMS, KITCHENS, ROOFTOPS, OUTDOORS, AND WITHIN 6FT. OF A SINK SHALL BE GFCI (OR SERVED BY A GFI CIRCUIT BREAKER) PER NEC 210.8(B). THE E.C. SHALL PROVIDE GFCI OUTLETS (OR CIRCUIT BREAKERS) IN ALL LOCATIONS REQUIRED BY THE NEC. ALL RECEPTACLES IN DWELLING UNITS, GUEST ROOMS, AND CHILD CARE FACILITIES (AS SPECIFIED BY ARTICLE 406 OF THE 2014 NEC) SHALL BE LISTED AS TAMPER -RESISTANT RECEPTACLES. 17. MINIMUM CONDUIT SIZE SHALL BE 3/4" UNLESS OTHERWISE INDICATED. CONDUITS LARGER THAN 2" DIAMETER OR CONDUITS OF ANY SIZE ROUTED OUTDOORS SHALL BE INTERMEDIATE METAL CONDUIT (IMC 18. FLEXIBLE CONDUIT CONNECTIONS TO RECESSED LIGHTING FIXTURES SHALL BE MADE WITH FLEXIBLE STEEL CONDUIT, 3/8 INCH MINIMUM. 19. FINAL CONNECTIONS TO MOTORS SHALL BE MADE WITH LIQUID TIGHT FLEXIBLE STEEL CONDUIT, 1 /2 INCH MINIMUM. 20. WIRE NO. 8 AND SMALLER INSTALLED IN DRY LOCATIONS SHALL BE TYPE THWN OR THHN THERMOPLASTIC 600V INSULATED COPPER CONDUCTORS. NO WIRE SMALLER THAN NO.12 SHALL BE USED FOR LIGHTING OR POWER WIRING. WIRE NO. 8 AND LARGER SHALL iBFSTRANDED. ALL CONDUCTORS INSTALLED IN EXTERIOR OR WET LOCATIONS SHALL BE TYPE THWN 60DV INSULATED COPPER CONDUCTORS. 21. ALL NEW CIRCUIT BREAKERS FOR NEW OR EXISTING PANELBOARDS SHALL 9,9ATCH EXISTING OR NEW BUILDING STANDARD PANELBOARD MANUFACTURER AND BREAKER TYPE. TjE CONTRACTOR SHALL PROVIDE NEW ACCURATE AND DETAILED TYPE WRITTEN PANEL DIRECTORICS'R NEC 4084 FOR ALL NEW OR MODIFIED PANELS. NUMBERED CIRCUITS ARE FOR CONVENIENCE OF DESIGN ONLY. E.C. TO FIELD VERIFY ACTUAL CIRCUIT NUMBERS USED AND CORRECTLY INDICATE ON "AS -BUILT" DRAWINGS. THE E.C. SHALL REMOVE ALL ABANDONED CIRCUITS. 22. PROVIDE #10 FOR BRANCH CIRCUITS OVER 75' AT 120V AND OVER 150' A" 277V. E.C. TO FIELD VERIFY BRANCH CIRCUIT LENGTHS AND SIZE CONDUCTORS FOR VOLTAGE DROP. 23. EACH SWITCH, LIGHT, RECEPTACLE AND ALL OTHER DEVICES SHALL BE PROVIDED AND INSTALLED WITH A GALVANIZED OR SHERARDIZED PRESSED STEEL JUNCTION BOX OF NOT LESS THAN NO. 14 U.S. GAUGE STEEL. CONDUITS SHALL BE FASTENED WITH LOCKNUTS AND BUSHINGS AND ALL UNUSED KNOCKOUTS MUST BE LEFT SEALED. THERE MUST BE SUFFICIENT ROOM FOR WIRES AND BUSHINGS AND DEEP BOXES SHALL BE INSTALLED WHERE REQUIRED. BOXES SHALL BE SECURELY AND ADEQUATELY SUPPORTED. 24. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SPECIAL OUTLET BOXES THAT MAY BE REQUIRED TO ENCLOSE RECEPTACLES. 25. IN SUSPENDED CEILINGS SUPPORT CONDUIT AND JUNCTION BOXES DIRECT FROM THE STRUCTURAL SLAB, DECK, OR FRAMING PROVIDED FOR THAT PURPOSE. LIGHTING BRANCH CIRCUIT CONDUITS SHALL NOT BE CLIPPED TO THE CEILING SUPPORT WIRES OR SPLINE UNLESS THE CEILING SYSTEM HAS BEEN SPECIFICALLY DESIGNED FOR THAT PURPOSE. 26. PROVIDE LOCAL DISCONNECT SWITCHES FOR ALL MOTORS (PLENUM APPROVED WHERE REQUIRED). 27. THE E.C. SHALL INCLUDE IN HIS COST THE REMOVAL OF ALL EXISTING ELECTRICAL DEVICES, CONDUITS, FIXTURES AND EQUIPMENT THAT IS NOT TO BE REUSED DISCARD ALL EQUIPMENT AS REQUIRED. E.C. SHALL BE RESPONSIBLE FOR DISCONNECTING PRIMARY SERVICE AND TEMPORARY POWER. 28. PROVIDE WARRANTY GUARANTEED FOR A PERIOD OF ONE YEAR AFTER COMPLETION AND ACCEPTANCE. REPLACE ALL DEFECTIVE WORKMANSHIP, EQUIPMENT AND MATERIALS WITHOUT ADDITIONAL CHARGES. 29. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFEKEEPING OF HIS/HER OWN PROPERTY ON THE JOB SITE. THE OWNER OR TENANT ASSUMES NO RESPONSIBILITY FOR PROTECTION OF THIS CONTRACTOR'S PROPERTY AGAINST FIRE, THEFT, OR ENVIRONMENTAL CONDITIONS. 30. WHERE CONDUIT, CABLES, DUCTWORK OR PIPING PASSES THROUGH FIRE RATED FLOORS, WALLS, OR PARTITIONS, THE SLEEVES SHALL BE COMPLETELY SEALED WITH A FIRE STOP MATERIAL THAT IS U.L. LISTED (EQUAL TO DOW CORNING) AND ACCEPTED BY THE BUILDING DEPARTMENT AND FIRE DEPARTMENT AS BEING SUITABLE FOR THE SERVICE. THIS MATERIAL SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTRUCTIONS IN ORDER TO MAINTAIN THE FIRE RATING OF THE PENETRATED WALL, FLOOR, OR PARTITION. INSTALLATION SHALL BE A THROUGH -PENETRATION FIRESTOP SYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH ASTM AND UL . THE FIRE RATING SHALL MATCH THE RATING OF THE BARRIER BEING PENETRATED. 31. SUBMIT SIX (6) SETS OF SHOP DRAWINGS, CONTROL DIAGRAMS, AND EQUIPMENT CUTS TO THE ENGINEER FOR APPROVAL PRIOR TO STARTING RELATED WORK. SHOP DRAWINGS SHALL INCLUDE MANUFACTURER'S NAMES, CATALOG NUMBERS, CUTS, DIAGRAMS AND OTHER SUCH DESCRIPTIVE DATA AS MAY BE REQUIRED TO IDENTIFY AND REVIEW THE EQUIPMENT. SUBMITTALS SHALL BE IN LOGICAL GROUPS, PARTIAL SUBMITTALS WILL NOT BE REVIEWED. 32. UPON COMPLETION OF CONSTRUCTION, SUPPLY THE ENGINEER WITH ONE COMPLETE SET OF FULL SIZE AS -BUILT DRAWINGS. PROVIDE THE OWNER WITH THREE (3) SETS OF OPERATION AND MAINTENANCE MANUALS FOR EACH TYPE OF EQUIPMENT INSTALLED. 33. THIS CONTRACTOR SHALL ASSUME ALL ADDED EXPENSES TO ALL TRADES ASSOCIATED WITH THE INSTALLATION OF SUBMITTED AND APPROVED ALTERNATE EQUIPMENT. 34. THE CONTRACTOR SHALL COORDINATE THE LAYOUT OF THE FIRE ROOM WITH ALL OTHER DISCIPLINES, ESPECIALLY THE FIRE ALARM AND FIRE PROTECTION DESIGN -BUILD CONTRACTORS PRIOR TO ANY WORK. 35. IF ANY CHANGES ARE MADE TO ACCOMMODATE FIELD CONDITIONS NOTIFY THE ENGINEER IMMEDIATELY OF WHAT THE CHANGES WERE, THE REASON FOR THE CHANGES, AND THE COST IMPACTS. ELECTRICAL LEGEND NOTE: NOT ALL ITEMS APPEAR ON DRAWINGS. SYMBOLS MAY DIFFER FROM EXISTING AND DEMO WORK OR DEVICES REFERENCED FROM DRAWINGS BY OTHERS. POWER AND LIGHTING LOW VOLTAGE SYSTEMS GROUNDED SWITCHED DUPLEX RECEPTACLE TELEPHONE TERMINAL BOARD GROUNDED SPLIT -WIRED RECEPTACLE FLOOR/CEILING MOUNTED DATA OUTLET GROUNDED DUPLEX RECEPTACLE FLOOR/CEILING MOUNTED TELEPHONE OUTLET GROUNDED QUADRAPLEX RECEPTACLE 0 DATA OUTLET SPECIAL PURPOSE RECEPTACLE O TELEPHONE/DATA OUTLET, PROJECT STANDARD DI FLOOR/CEILING MOUNTED RECEPTACLE V TELEPHONE OUTLET 0 JUNCTION BOX CATV/MONITOR A/V OUTLET O SPEAKER WALL MOUNTED JUNCTION BOX FACP FIRE ALARM PANEL 0J EQUIPMENT DISCONNECT SWITCH FAA FIRE ALARM REMOTE ANNUNICATOR OJ EQUIPMENT FUSED DISCONNECT SWITCH • PANEL S T S-SMOKE, T-HEAT DETECTOR $To THERMAL OVERLOAD SWITCH 0: DUCT FIRE DETECTOR ELECTRICAL PANEL BOARD ABBREVIATIONS R TRANSFORMER CIRCUIT'##' HOMERUN TO PANEL'X' (ARROWS NOT USED IF CIRCUIT NUMBERS APPEAR NEXT TO DEVICES) O PORCELAIN LAMP HOLDER RECESSED FLUORESCENT LIGHT FIXTURE O SURFACE MOUNTED FLUORESCENT FIXTURE O CEILING FIXTURE ®Y WALLWASHER .,ADJUSTABLE DOWNLIGHT $# SINGLE POLE SWITCH, OR #-POLE $D DIMMER SWITCH ® EXIT SIGN - SHADED INDICATES FACE p® EMERGENCY FIXTURE - SHADED O BATTERY PACK EMERGENCY LIGHT or COMBO EXIT - SEE SCHEDULE EWC ELECTRIC WATER COOLER EF EXHAUST FAN GFI GROUND FAULT INTERRUPTING AN ARC FAULT INTERRUPTING CCT CIRCUIT E.C. ELECTRICAL CONTRACTOR AG ABOVE COUNTER GFI - VERIFY HEIGHT AC ABOVE COUNTER - VERIFY HEIGHT WP WEATHER PROOF TTB TELEPHONE TERMINAL BOARD AFF ABOVE FINISH FLOOR AHJ AUTHORITY HAVING JURISDICTION (E) EXISTING TO REMAIN (EX) EXISTING TO BE REMOVED (ER) EXISTING TO BE RELOCATED (R) RELOCATE/RELOCATED LOCATION REFERENCE SYMBOLS O KEYED NOTE OO EQUIPMENT - SEE SCHEDULE ® FEEDER - SEE SCHEDULE R kVA TRANSFORMER WITH GROUNDING AND OVERCURRENT DEVICES SEE I TRANSFORMER SCHEDULE too arranges shall be matte to the SCOpe of work writl{{.,cl.2t prior apProvai of Tu!�",;':a Buildin3 Division. (:i�;E, F = z. a s will require a ns� r plan submittal and may in;�uc L*I adOonal Plan rev r ffts. I � ' 3 FbR: V'�2'-_hanical I� . t:bing s Piping 1 Y ' .' of TL�°!w1la Plan r&view appro�+aI is suis at t>o errors and omissions. ::rovai of :Cr18%rElUiiC7t1 documents dogs not authorize the violation of any adoptod Coda or ordinance. Fiscoipt of approved ; ioid Copy. and ooradi ions is aoknowlOdgod: l '1' Date: City of Tukwila BUILDING DIVISION REVIEWED .FUH COMPLIANCE WITH NFPA 70 - NEC DEC 17 2015 City of Tukwila BUILDING DIVISION z' J i' . Uf.!'\' I NOV 2 0 2015 `'ER_N"Ii T CENTER DQSIGNPARAMQTCRS, LLC 6373 SILVCR STRC-AM LN �--RISCO. TX 75034 PN: 214.784.5014 �X: 303.223.g 104 DQSIGN PARAMCTCRS•COM John Tinsley, P.E. 38140 Fawn Meadows Tr. Elizabeth, Colorado 80707 Phone: 303.646.1860 Fax: 303.646.5623 p4 - �1 • . • START DATE • oaS= PROJECT NO • 7M DRAWN BY CHECKED BY• ISSUEDAEVISED • • DATE P9FAU 11.132MS EXPIRES: 11/15/2017 ONE -LINE, NOTES & SCHEDULES 1 mo�i cornuaxronal-ni. I. (I)KCI-E:rI/iI.LC 3MALL Dt: LUUAItU t5tLUVV I17t IAbLt. I.UNt-IKM '" 1— - 111" 1III ^'"'- '. Nt l 1 LI\ vvl11l L-f i 1\L-L./1\ILLLL/ 1\.J t.IRl.Ul1 D-J/. I.UUICLJ11VHlC IWA%._I LUI./'HIIUIv HIVU 1. PROVIDE OUTLET WITHIN 25' OF EQUIPMENT IN ACCORDANCE WITH NEC 210-63. PROVIDE EXACT MOUNTING HEIGHT WITH ARCHITECT PRIOR TO HOLES ACCORDING TO NEMA STANDARDS. INSTALL ON 2" REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO WEATHERPROOF GFI OUTLET ON ROOFTOPS WITHIN 25' OF ROOFTOP EQUIPMENT. ROUGH -IN. STANDOFF INSULATORS. CONNECT DIRECTLY TO MAIN BUILDING INSTALLATION. _ GROUND. (INSULATED GREEN INSULATED CABLE MINIMUM #2/0 16. APPROXIMATE LOCATION OF MARLIN LIGHTING CONTROL BOX. 2. FIELD VERIFY FINAL LOCATION OF ALL EQUIPMENT WITH PROVIDER PRIOR TO ROUGH -IN. REVIEWEDFOR OR 2. RECEPTACLE AND TV OUTLET SHALL BE LOCATED ABOVE THE TABLE. CONFIRM EXACT MOUNTING HEIGHT WITH ARCHITECT AWG SHALL BE USED). MOUNT 12" A.F.F. EQUAL TO ERICO COORDINATE EXACT LOCATION &REQUIREMENTS WITH OWNER 3. ALL RECEPTACLES IN BATHROOMS KITCHENS ROOFTOPS, OUTDOORS, AND WITHIN 6FT. OF A COMPLIANCE WITH PRIOR TO ROUGH -IN. #BS44A017. CONNECT TO PANEL C ISOLATED GROUND BAR. & MANUFACTURER PRIOR TO INSTALLATION. SINK SHALL BE GFCI (OR SERVED BY A GFI CIRCUIT BREAKER) PER NEC 210.8(B). THE E.C. SHALL NFPA70 o NEC 9. NOT USED, PROVIDE GFCI OUTLETS (OR CIRCUIT BREAKERS) IN ALL LOCATIONS REQUIRED BY THE NEC. 3. RECEPTACLE SHALL BE LOCATED UNDER THE VANITY. 17. PROVIDE AND INSTALL DOOR BELL. COORDINATE EXACT N S CIDWELLING UNITS, GUEST ROOMS, AND CHILD CARE FACILITIES (AS SPECIFIED BY ALL RECEPTACLES 4. JUNCTION BOX SERVE POWER SUPPLY FOR HANDS FREE DEVICE. 10. PROVIDE (3) 4" CONDUITS FROM AN EQUIPMENT IN OFFICE REQUIREMENTS WITH OWNER/ARCHITECT. 4. DEC 17 2015 POWER IS REQUIRED TO FIRST JUNTION BOX AND LOW VOLTAGE DOWN COLUMN AND UNDER SLAB TO AN MILLWORK. SEE 18. PROVIDE AND INSTALL POWER TO MOTORIZED INSECT SCREENS ARTICLE 406 OF THE 2011 NEC) SHALL BE LISTED AS TAMPER -RESISTANT RECEPTACLES. ARCHITECTURAL PLANS FOR MORE INFO. 5. PROVIDE CONNECTION TO TENANT SIGN. FIELD VERIFY ELECTRICAL REQUIREMENTS AND FINAL POWER CONNECTION EXTENDS TO REMAINING FAUCETS. WITH SWITCHES ON WALL. COORDINATE EXACT LOCATION AND 11LOCATION WITH PROVIDER, TENANT AND LANDLORD. PROVIDE PHOTOCELL ON/TIMECLOCK OFF (�i'ty Of•TUkWII�,. � 5. MOUNT 4-PLEX RECEPTACLES FOR TV'S AT STRUCTURE ABOVE BAR. . APPROXIMATE LOCATION OF MARLIN LIGHTING CONTROL CAB REQUIREMENTS WITH ARCH &MECHANICAL PRIOR TO RELAY BOARD AND TIME CLOCK. COORDINATE EXACT LOCATION INSTALLATION. CONTROLS. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE INSTALLATION. REFER TO ARCHITECTURAL DRAWINGS &DETAILS. BUILDING DIVISION & REQUIREMENTS WITH OWNER & MANUFACTURER PRIOR TO 19. PROVIDE AND INSTALL POWER TO ELECTRONIC GAS LIGHTER.6. NUMBERS NEXT TO DEVICES REFER TO CIRCUIT DESIGNATION IN UNIT PANEL UNLESS NOTED. �RI CK 6. RECEPTACLE SERVES SURFACE MOUNTED WIREMOLD INSTALLED INSTALLATION.Q, ?� ALONG THE UNDERSIDE OF THE BAR COUNTER FOR USE BY CONNECT TO CIRCUIT B-38. COORDINATE EXACT LOCATION 7. ALL TELE/DATA LOCATIONS SHALL INCLUDE 4" SQUARE J-BOX AND 3/4" CONDUIT TO CEILING 4 �o� wasHf 1 12. PROVIDE AND INSTALL POWER TO IN -LINE FAN AT FIRE PIT FLUE. AND REQUIREMENTS WITH ACTUAL EQUIPMENT FURNISHED. SPACE. ALL TELEPHONE/DATA CABLE IS TO BE PLENUM RATED WIRE OR SHALL BE INSTALLED IN PATRONS. PROVIDE GFI RECEPTACLE AT THE ORIGIN OF FEED, WIREMOLD SHALL HAVE SIMPLEX RECEPTACLES @ 24" ON CENTER CONNECT TO CIRCUIT B-42. COORDINATE EXACT LOCATION CONDUIT ABOVE CEILING OR IN WALLS. AND REQUIREMENTS WITH ACTUAL EQUIPMENT FURNISHED. _ j', : '7 _€ (SIMILAR TO WIREMOLD 2000 SERIES). REFER TO ARCHITECTURAL 8. PROVIDE ALL DEMOLITION WORK AS REQUIRED TO ACCOMMODATE THE NEW WORK AS INDICATED! , ,�; , N If L A DETAIL FOR MOUNTING LOCATION. 13. POWER STRIPS TO BE MOUNTED UNDERNEATH THE BAR AREA. ON THE ELECTRICAL PLANS. FIELD VERIFY EXISTING CONDITIONS. PROVIDE ANY ADDITIONAL WORK COORDINATE EXACT LOCATION AND REQUIREMENTS WITH NECESSARY AS REQUIRED TO PRESERVE EXISTING DEVICES AND BRANCH CIRCUIT COMPONENTS TO BOA � GISTER�� § 7. PROVIDE 4'X8'X1"FIRE TREATED PLYWOOD TELEPHONE OWNER/ARCHITECT PRIOR TO INSTALLATION. REMAIN. REFER TO THE ARCHITECTURAL PLANS FOR DEMOLITION SCOPE OF WORK AND VISIT THE NOV Z O 2015 `rs10NA1, $ BACKBOARD. MOUNT FLUSH TO CEILING, PAINT WITH 2 COATS TO MATCH WALLS. #6 (AWG) GROUND TO BUILDING GROUND 14. PROVIDE AND INSTALL POWER TO AIR CURTAIN FAN WITH SWITCH SITE PRIOR TO BID TO DETERMINE THE ELECTRICAL SCOPE OF WORK REQUIRED. PERMIT CEENTER EXPIRES: 11/15/2017 SYSTEM. LEAVE 3' COILED UP AT BACKBOARD. GROUND ALL ON WALL. COORDINATE EXACT LOCATION AND REQUIREMENTS RACKS, CABLE TRAY WITHIN ROOM. WITH MECHANICAL CONTRACTOR PRIOR TO INSTALLATION. POWER PLAN 2mOl 00"Rl6Xi0202-n16 f:� LF-04 0 LF-02 DM-1 1�1 I i ............. N.L. ' LF-13 j LF-13 i _ a ! iLA .... [ B5 ti f € NO 'THROUGH LIGHTING i jA xenI 1€ 1 t CONTACTOR f t n� I t : f t i{ __ - € €€ <:. ii -- O i t....... _-._......................_....: - - - - - - - - - - s - - i!€ i 1.; LF X1 LF 01 " pM A-3 A-3 1 —02 m - . 1 � LF 3 t : i I: : : , : i N\I , LF-01 DNI 1:.0 _...--- - i .O -- -- l DM-4 LF-01 . DM-'10 LF-02 : . .. ..... .. ....... _....... __� ., , I i i f , :......... ... .................... . .._. _ ...... _ t ODM 5 LF-01 0 M-10 ....--- LF 01 C LF-01 N.L. DM-10 J DM-4 _ LF-02 _ __. LF-01 — O DM-10 _._— ......_........._._...... ---! — _ 1 ' ----- DM LF-01 O LF— 3 : -- DM=10 O LF '01C —_ LF-01. DM_' IQ ........_... — — _ --- e DM-4 --- — LF-02 ..... -_._ ........ _1 ._....--_.... ............. ........... - LF 3 O LF-01 DM-10 O LF701 DM-10 .. _— — _...._., \ ..... _ - - - _ ...... ..... REFER.IO E2,03..FQI ............................_... B=5 = Ni N L COOLER/ REEZERS LIGHTING CIRCUITS F NOT THROUGH LIGHTING CONTACTOR DM-4 -X1 LF-02 E7Q LF-01 LF 04 9-8 LF-04 B-8 .............. 1 LIGHTING PLAN E2.0 SCALE: 1 /8" = 1'-0" LIGHTING PLAN GENERAL NOTES: O LIGHTING PLAN KEYED NOTES: 1. CONNECT EGRESS LIGHTING FIXTURES AND EXIT SIGNS TO AREA LIGHTING CIRCUIT AHEAD OF 1 • DUAL LEVEL SWITCHING — PROVIDE IN ACCORDANCE WITH IECC REQUIREMENTS. PROVIDE ALL ANY SWITCH PER NEC 700-12(F) INCLUDING ANY NIGHT LIGHTS. FIXTURES SHOWN SHADED OR LIGHTING WITH DUAL BALLASTS FOR SEPARATE CONTROL OF INBOARD AND OUTBOARD LAMPS LABELED ARE EMERGENCY EGRESS (EM) WITH BATTERY PACK, NIGHT LIGHT (NL) OR BOTH OR CONNECT ALTERNATE FIXTURES TO SEPARATE SWITCH AS INDICATED FOR LIGHT REDUCTION (EM/NL). REMOVE ANY HOUSE PANEL CIRCUITS SERVING EXISTING EMERGENCY AND EXIT LIGHTS AND RECONNECT TO THE TENANT PANEL. CONTROL BY AT LEAST 50% IN A REASONABLY UNIFORM ILLUMINATION PATTERN. 2. PROVIDE OUTLET IN ACCESSIBLE LOCATION AT TENANT ENTRANCE FOR SIGN PER NEC 600-5. 2. APPROXIMATE LOCATION OF MARLIN LIGHTING CONTROL RELAY PANEL. COORDINATE EXACT 3. NUMBERS NEXT TO DEVICES REFER TO CIRCUIT DESIGNATION IN UNIT PANEL UNLESS NOTED. REQUIREMENTS WITH OWNER/MANUFACTURER PRIOR TO INSTALLATION. 3. APPROXIMATE LOCATION OF MARLIN LIGHTING CONTROL BOX. COORDINATE EXACT REQUIREMENTS WITH OWNER/MANUFACTURER PRIOR TO INSTALLATION. REVIEWED F l' COMPLIANCE WITS NFPA70 - NEC DEC 17 2015 ! Y "F t OF "l Uf A iL A NOV 2 0 2015 -1_h111 iT C:EcNTER Di-SIGNPARAMF=TQRS, LLC 6373 SILVQR STRI=AM LN FRISCO. TX 75034 PSI: 214-784.5014 1=X: 303.223.Q I04 DQSIGNPARAM�;TQRS.COM John Tinsley, P.E. 38140 Fawn Meadows Tr. Elizabeth, Colorado 80707 Phone: 303.646.1860 Fax: 303.646.5623 — . .. ti 7 • START DATE • E1B25.2415 PROJECT NO • Tem DRAWN BY CHECKED BY - ISSUED/REVISED • • DATE PEST 11A2m6 I KITCHEN EQUIPMENT PLAN SCALE: 1 /4" = 1'-0" POWER PLAN GENERAL NOTES: 1. PROVIDE OUTLET WITHIN 25' OF EQUIPMENT IN ACCORDANCE WITH NEC 210-63. PROVIDE WEATHERPROOF GFI OUTLET ON ROOFTOPS WITHIN 25' OF ROOFTOP EQUIPMENT. 2. FIELD VERIFY FINAL LOCATION OF ALL EQUIPMENT WITH PROVIDER PRIOR TO ROUGH -IN. 3. ALL RECEPTACLES IN BATHROOMS, KITCHENS, ROOFTOPS, OUTDOORS, AND WITHIN 6FT. OF A SINK SHALL BE GFCI (OR SERVED BY A GFI CIRCUIT BREAKER) PER NEC 210.8(B). THE E.C. SHALL PROVIDE GFCI OUTLETS (OR CIRCUIT BREAKERS) IN ALL LOCATIONS REQUIRED BY THE NEC. 4. ALL RECEPTACLES IN DWELLING UNITS, GUEST ROOMS, AND CHILD CARE FACILITIES (AS SPECIFIED BY ARTICLE 406 OF THE 2011 NEC) SHALL BE LISTED AS TAMPER -RESISTANT RECEPTACLES. 5. PROVIDE CONNECTION TO TENANT SIGN. FIELD VERIFY ELECTRICAL REQUIREMENTS AND FINAL LOCATION WITH PROVIDER, TENANT AND LANDLORD. PROVIDE PHOTOCELL ON/TIMECLOCK OFF CONTROLS. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE INSTALLATION. 6. NUMBERS NEXT TO DEVICES REFER TO CIRCUIT DESIGNATION IN UNIT PANEL UNLESS NOTED. 7. ALL TELE/DATA LOCATIONS SHALL INCLUDE 4" SQUARE J-BOX AND 3/4" CONDUIT TO CEILING SPACE. ALL TELEPHONE/DATA CABLE IS TO BE PLENUM RATED WIRE OR SHALL BE INSTALLED IN CONDUIT ABOVE CEILING OR IN WALLS. 8. PROVIDE ALL DEMOLITION WORK AS REQUIRED TO ACCOMMODATE THE NEW WORK AS INDICATED ON THE ELECTRICAL PLANS. FIELD VERIFY EXISTING CONDITIONS. PROVIDE ANY ADDITIONAL WORK NECESSARY AS REQUIRED TO PRESERVE EXISTING DEVICES AND BRANCH CIRCUIT COMPONENTS TO REMAIN. REFER TO THE ARCHITECTURAL PLANS FOR DEMOLITION SCOPE OF WORK AND VISIT THE SITE PRIOR TO BID TO DETERMINE THE ELECTRICAL SCOPE OF WORK REQUIRED. 9. FIELD VERIFY FINAL LOCATIONS OF ALL KITCHEN EQUIPMENT PRIOR TO ANY WORK. 50.1 g1 1 81 0 0 0 e C❑IL C❑NNECTI❑NS TO BE BY REFRIGERATI❑N CONTRACTOR COIL C❑NNECTI❑NS TO BE BY REFRIGERATI❑N CONTRACTOR REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC DEC 17 2015 City 0$ TukWif6 _ BUILDING DIVISION NOV 2 0 2015 PERMIT CENTER DE-SIGNPARAM9TRS, LLC 6373 SILVER STRI=AM LN �RISCO. TX 75034 Pl-: 214.784.5014 1:X: 303.223. C,104 DCSIGN PARAM9TCRS.COM John Tinsley, P.E. 38140 Fawn Meadows Tr. Elizabeth, Colorado 80707 Phone: 303.646.1860 Fax: 303.646.5623 .tgI CIK ? 4 �F WASk fr y 4127 �0 IST IONAL EXPIRES: 11/15/2017 19TCHEN EQUIPMENT PLAN 2mO3 COPMaH102Me-sou 0 la to LIGHTING CONTACTOR SCHEDULE LC-1 12 POLE 30A ELECTRONICALLY HELD NEMA 1 ENCLOSURE INDOOR LIGHTING TIME CLOCK CONTROL LC-2 12 POLE 30A ELECTRONICALLY HELD NEMA 1 ENCLOSURE OUTDOOR LIGHTING (SECURITY) PHOTO CELL CONTROL LC-3 12 POLE 30A ELECTRONICALLY HELD NEMA 1 ENCLOSURE OUTDOOR LIGHTING (SIGN) FLOOD LIGHTS, CANOPY LIGHTS TIME CLOCK CONTROL PROVIDE AND INSTALL CODE CABINET WITH HINGED DOOR SIZE CONTACTOR ENCLOSURE AND LATCH DIMMER PANEL DM SCHEDULE MARLIN SMP-8 & SMP-4 WITH i (2) INCANDESCENT DIMMERS & (10) LED DIMMER MODULES 120V. FEED THROUGH DIMMER # SERVES LOAD TYPE. WATTS CCT. # TO DIMMER DM-1 CHANDELIERS DINING INCANDESCENT 1385 WATTS B-1 DM-2 CORNER BOOTH SCONCES INCANDESCENT 240 WATTS B-3 DM-3 NORTH DINING LED ELV 369 WATTS B-5 DM-4 TRUSS LIGHTING LED ELV 117 WATTS B-44 DM-5 BOOTH LIGHTING LED ELV 99 WATTS B-46 DM-6 SOUTH LIGHTING LED ELV 243 WATTS B-48 DM-7 BAR TRUSS LIGHTING LED ELV 144 WATTS B-50 DM-8 BAR SEATING LIGHTING LED ELV 98 WATTS B-52 DM-9 BAR DOWN LIGHTS LED ELV 45 WATTS B-54 DM-10 WAITRESS PICK UP LED ELV 77 WATTS B-56 DM-11 PATIO DINING LED ELV 288 WATTS B-58 DM-12 DECOR TRACK LOW VOLTAGE TRACK W/ MAG-TX & LED BULBS 105 WATTS B-60 INSTALL PER MANUFACTURER REQUIRMENTS TECHNICAL DIMMING SYSTEM CONTROL DETAIL GENERAL NOTES: 1. INFORMATION SHOWN ON THIS DETAIL IS DIAGRAMMATIC ONLY. VERIFY EXACT PART/MODEL NUMBER OF EACH COMPONENT AND ALL NECESSARY MATERIALS, AS REQUIRED FOR AN OPERABLE MARLIN CONTROLS DIMMING SYSTEM, WITH MARLIN CONTROLS PRIOR TO BID, CONTACT tech@marlincontrols.com OR 1 (800) 788-5750 FOR TECHNICAL SUPPORT. 2. OPERATING VOLTAGE: 120 VAC, FEED -THROUGH ONLY. 3. FEED -THROUGH SYSTEM - CONTAINS NO CIRCUIT BREAKERS. 4. RUN A SEPARATE NEUTRAL PER CIRCUIT INTO THE DIMMER CABINET. 5. LOW -VOLTAGE WIRING: REQUIRES 4-CONDUCTORS, 20 AWG, BELDEN #9402 SHIELDED CABLE. 6. FLUORESCENT BALLASTS: COMPATIBLE WITH ADVANCED MARK X DIMMABLE BALLAST. COVER DIMENSION: 12"W X 16"H X 5.25"D iS B COVER DIMENSION: 12"W X 12"H X 5.25"D ® = 3/C - #20 AWG SHIELDED CABLE BELDEN #9402 ® = 3/C - #20 AWG SHIELDED CABLE BELDEN #9939 * LOCATE IN MANAGER'S OFFICE O LOCATE IN WAITRESS PICKUP AREA SMP 4 * B-29 ----�,�-PROVIDED OUTDOOR PHOTOCELL BY MARLIN STELLAR RMS 8 O HERCULES TIMECLOCK FITS INTO A 3GANG FITS INTO A 2GANG RACO #697 SWITCH BOX RACO #696 SWITCH BOX IN OFFICE NEUTRAL TYPICAL -- - LIGHTING CONTACTORS NO I ,I; LC-1. LC-2. & LC-3 C NOTE: 120 VAC ELECTRICALLY HELD LIGHTING CONTACTORS FURNISHED BY EC DC III RELAY BOARD ENCLOSURE DIMENSION: 12"W X 12"H X 4"D N M A On"L I ON gnu" I M M I 0N'nG R 15 E 0 U I nPh M E 'N"T WIR111101"G D1 AGR A IV PANEL SCHEDULE: K November 16, 2015 PROJECT: Twin Peaks - Washington VOLTAGE L-L: 208 LOCATION: Main Kitchen VOLTAGE L-G: 120 JOB NO.: 15-120 SYSTEM: 30, 4-WIRE COMMENTS: New Nema 1 Panel BUS RATING: 400A S.C.RMS RATING: 42,000 AIC MAIN O.C. DEVICE: MLO MOUNTING: Recessed CIR CIRCUIT BREAKER CONNECTED NEC DEMAND DESCRIPTION OF PHASE DESCRIPTION OF NEC DEMAND CONNECTED CIRCUIT BREAKER CIR AMPS POLE POLE AMPS NO. LOAD (VA) FACTOR LOAD SERVED LOAD SERVED FACTOR LOAD (VA) NO. 1 20 1 920 0.65 E079 GLASS CHILLER REFRIG. , . E056 SODA EQUIPMENT 0.65 1200 1 20 2 3 20 1 920 0.65 E079 GLASS CHILLER REFRIG. B E054 BREWING EQUIPMENT 0.65 1350 2 20 4 5 20 1 920 0.65 E079 GLASS CHILLER REFRIG. C- E054 BREWING EQUIPMENT 0.65 1350 2 20 6 7 20 1 920 0.65 E079 GLASS CHILLER REFRIG. A E010 ICE MAKER 0.65 140 1 20 8 9 20 1 920 0.65 E079 GLASS CHILLER REFRIG. B E010 ICE MAKER 0.65 140 1 20 10 11 20 1 840 0.65 E080 U/C REFRIG C E089 HEAT STRIP 0.65 2050 2 30 12 13 20 1 1920 0.65 E087 BLENDER :^. E089 HEAT STRIP 0.65 2050 2 30 14 15 20 1 1920 0.65 E087 BLENDER 8 E089 HEAT STRIP 0.65 2400 2 30 16 17 20 1 600 0.65 E094 SODA GUN C E089 HEAT STRIP 0.65 2400 2 30 18 19 20 1 600 0.65 E094 SODA GUN , . E049 PIZZA REFRIG 0.65 1040 1 20 20 21 20 1 700 0.65 El 14 GLASS CHILLER E E060 SANDWICH REFRIG 0.65 600 1 20 22 23 20 1 800 1.00 EE03 BAR RECPTS C E047 HOT FOOD TABLE 0.65 1500 2 20 24 25 20 1 800 1.00 EE03 BAR RECPTS A. E047 HOT FOOD TABLE 0.65 1500 2 20 26 27 20 1 1920 0.65 EE04 CHEMICAL DISPENSER is E045 PIZZA REFRIG 0.65 950 1 20 28 29 20 1 1920 0.65 EE04 CHEMICAL DISPENSER C: E040 WORK -TOP FREEZER 0.65 740 1 20 30 31 20 1 610 1.00 E109 FLY FAN A E089 HEAT STRIP 0.65 2050 2 30 32 33 20 1 1200 1.25 E067 COOLER LTS E E089 HEAT STRIP 0.65 2050 2 30 34 35 20 1 840 1.25 E014 WALK-IN FREEZER LTS C E123 ICE CREAM FREEZER 0.65 700 1 20 36 37 20 1 840 1.25 E014 WALK-IN FREEZER LTS A E042 MICROWAVE 0.65 1560 1 20 38 39 20 1 800 1.00 EE02 RECEPTS KITCHEN S E032 ROTARY TOASTER 0.65 1400 2 20 40 41 20 1 800 1.00 EE02 RECEPTS KITCHEN C E032 ROTARY TOASTER 0.65 1400 2 20 42 43 20 1 400 1.00 EE02 RECEPTS KITCHEN A E052 CHEESE MELTER 0.65 1800 2 25 44 45 20 1 800 1.00 EE02 RECEPTS KITCHEN B E052 CHEESE MELTER 0.65 1800 2 25 46 47 20 1 800 1.00 EE02 RECEPTS KITCHEN C E104 WARMING DRAWER 0.65 900 1 20 48 49 20 1 400 1.00 EE02 RECEPTS KITCHEN A E042 MICROWAVE 0.65 1560 1 20 50 51 20 1 1000 1.00 ROOFTOP RECPTS B E125 HOOT FOOD WELL 0.65 1200 1 20 52 53 20 1 500 0.65 EF-4 DISHWASHER EF C E035 REFRIG. GRIDDLE STAND 0.65 1140 1 20 54 55 20 1 500 0.65 EF-5 GLASS WASHER EF A SHUNT TRIP 0 XX 56 57 15 2 990 0.65 E017 WALK-IN COOLER COND. B E035.1 REFRIG. BROILER STAND 0.65 1200 1 20 58 59 15 2 990 0.65 E017 WALK-IN COOLER COND. C SHUNT TRIP 0 XX 60 61 15 3 1370 0.65 E068 KEG COOLER COND. A E033 HEAT LAMP 0.65 630 1 20 62 63 15 3 1370 0.65 E068 KEG COOLER COND. E SHUNT TRIP 0 XX 64 65 15 3 1370 0.65 E068 KEG COOLER COND. C FRYER CONTROLS 0.65 1440 1 20 66 67 25 3 1370 0.65 E015 WALK-IN FREEZER COND. / • SHUNT TRIP 0 XX 68 69 25 3 1370 0.65 E015 WALK-IN FREEZER COND. B E028 PIZZA REFRIG. 0.65 950 1 20 70 71 25 3 1370 0.65 E015 WALK-IN FREEZER COND. E051 HOOD CONTROL/LTS 0.65 1500 1 20 72 73 70 3 5850 0.65 E120 GLASS WASHER A EO13 SODA SYSTEM 0.65 1200 1 20 74 75 70 3 5850 0.65 E120 GLASS WASHER 13 SPARE 0 1 20 76 77 70 3 5850 0.65 E120 GLASS WASHER C E044 NITROGEN SYSTEM 0.65 1200 1 20 78 79 20 1 800 1.00 EE02 RECEPTS KITCHEN 'r E013 SODA SYSTEM 0.65 1200 1 20 80 81 BUSSED SPACE 8 SPARE 1 20 82 83 BUSSED SPACE #_ SPARE 1 20 84 CONNECTED LOAD: DEMAND LOAD: PHASE A (VA): 33,230 PHASE A (VA): 23,157 PHASE B (VA): 33,800 PHASE B (VA): 23,600 PHASE C (VA): 33,920 PHASE C (VA): 23,392 TOTAL LOAD (VA): 100,950 TOTAL DEMAND LOAD (VA): 70,149 194.72 A NOTES: 1. PANEL SCHEDULE: M November 16, 2015 PROJECT: Twin Peaks - Washington VOLTAGE L-L: 208 LOCATION: Main Kitchen VOLTAGE L-G: 120 JOB NO.: 2015-120 SYSTEM: 30, 4-WIRE COMMENTS: New Nema 1 Panel BUS RATING: 200A S.C.RMS RATING: 42,000 AIC MAIN O.C. DEVICE: MLO MOUNTING: Surface CIR CIRCUIT BREAKER CONNECTED NEC DEMAND DESCRIPTION OF PHASE DESCRIPTION OF NEC DEMAND CONNECTED CIRCUIT BREAKER CIR AMPS POLE POLE AMPS NO. LOAD (VA) FACTOR LOAD SERVED LOAD SERVED FACTOR LOAD (VA) NO. 1 20 1 Spare ^. E003 DISHWASHER 0.65 5850 3 70 2 3 20 1 Spare B E003 DISHWASHER 0.65 5850 3 70 4 5 20 1 Spare E003 DISHWASHER 0.65 5850 3 70 6 7 20 1 Spare GYLCOL CHILLER 1.00 3150 3 40 8 9 20 1 Spare GYLCOL CHILLER 1.00 3150 3 40 10 11 20 1 Spare GYLCOL CHILLER 1.00 3150 3 40 12 13 20 1 Spare -. GYLCOL CHILLER 1.00 3150 3 40 14 15 20 1 Spare GYLCOL CHILLER 1.00 3150 3 40 16 17 20 1 Spare .. GYLCOL CHILLER 1.00 3150 3 40 18 19 20 1 Spare A MUA-1 1.00 2100 3 30 20 21 15 1 864 1.00 KEF-4 MUA-1 1.00 2100 3 30 22 23 15 1 864 1.00 KEF-5 C MUA-1 1.00 2100 3 30 24 25 15 3 300 1.00 KEF-1 :, E01 1 ICE MAKER COND. 0.65 1000 3 15 26 27 15 3 300 1.00 KEF-1 °• E01 1 ICE MAKER COND. 0.65 1000 3 15 28 29 15 3 300 1.00 KEF-1 E01 1 ICE MAKER COND. 0.65 1000 3 15 30 31 15 3 936 1.00 KEF-2 41, E01 1 ICE MAKER COND. 0.65 1000 3 15 32 33 15 3 936 1.00 KEF-2 " E01 1 ICE MAKER COND. 0.65 1000 3 15 34 35 15 3 936 1.00 KEF-2 C- E01 1 ICE MAKER COND. 0.65 1000 3 15 36 37 15 3 828 1.00 KEF-3 BUSSED SPACE 38 39 15 3 828 1.00 KEF-3 s BUSSED SPACE 40 41 15 3 828 1.00 KEF-3 BUSSED SPACE 42 CONNECTED LOAD: DEMAND LOAD: PHASE A (VA): 18,314 PHASE A (VA): 15,567 PHASE B (VA): 19,178 PHASE B (VA): 16,431 PHASE C (VA): 19,178 PHASE C (VA): 16,431 TOTAL LOAD (VA): 56,670 TOTAL DEMAND LOAD (VA): 48,428 134.43 A NOTES: 1. PANEL SCHEDULE: MDP November 16, 2015 PROJECT: Twin Peaks - Washington VOLTAGE L-L• 208 LOCATION: Electrical room VOLTAGE L-G: 120 JOB NO.: 2015-120 SYSTEM: 30, 4-WIRE COMMENTS: New Nema 1 Panel BUS RATING: 1600A S.C.RMS RATING: 65,000 AIC MAIN O.C. DEVICE: M.C.B. MOUNTING: Surface CIR CIRCUIT BREAKER CONNECTED NEC DEMAND DESCRIPTION OF PHASE DESCRIPTION OF NEC DEMAND CONNECTED CIRCUIT BREAKER CIR AMPS POLE POLE AMPS NO. LOAD (VA) FACTOR LOAD SERVED LOAD SERVED FACTOR LOAD (VA) NO. 1 400 3 15567 1.00 PANEL'M' A PANEL'C' 1.00 10900 3 150 2 1 400 3 16431 1.00 PANEL'M' B PANEL'C' 1.00 11100 3 150 2 1 400 3 16431 1.00 PANEL'M' C. PANEL'C' 1.00 9696 3 150 2 3 400 3 23157 1.00 PANEL'K' A PANEL'B' 1.00 16100 3 225 4 3 400 3 23600 1.00 PANEL'K S PANEL'B' 1.00 12888 3 225 4 3 400 3 23392 1.00 PANEL'K !' PANEL'B' 1.00 13423 3 225 4 5 200 3 23280 1.00 RTU-1 A RTU-2 1.00 23280 3 200 6 5 200 3 23280 1.00 RTU-1 RTU-2 1.00 23280 3 200 6 5 200 3 23280 1.00 RTU-1 RTU-2 1.00 23280 3 200 6 7 200 3 23280 1.00 RTU-3 A RTU-4 1.00 23280 3 200 8 7 200 3 23280 1.00 RTU-3 S RTU-4 1.00 23280 3 200 8 7 200 3 23280 1.00 RTU-3 C RTU-4 1.00 23280 3 200 8 9 Bussed Space A Bussed Space 10 9 Bussed Space iE.33 Bussed Space 10 9 Bussed Space C Bussed Space 10 CONNECTED LOAD: DEMAND LOAD: PHASE A (VA): 158,843 PHASE A (VA): 158,843 PHASE B (VA): 157,138 PHASE B (VA): 157,138 PHASE C (VA): 156,061 PHASE C (VA): 156,061 TOTAL LOAD (VA): 472,042 TOTAL DEMAND LOAD (VA): 472,042 1,310.30 A NOTES: 1. PANEL SCHEDULE: B November 16, 2015 PROJECT: Twin Peaks - Washington VOLTAGE L-L: 208 LOCATION: Electrical Room VOLTAGE L-G 120 JOB NO.: 15-120 SYSTEM: 30, 4-WIRE COMMENTS: New Nema 1 Panel BUS RATING: 225A S.C.RMS RATING: 42,000 AIC MAIN O.C. DEVICE: MLO MOUNTING: Surface CIR CIRCUIT BREAKER CONNECTED NEC DEMAND DESCRIPTION OF PHASE DESCRIPTION OF NEC DEMAND CONNECTED CIRCUIT BREAKER CIR AMPS POLE POLE AMPS NO. LOAD (VA) FACTOR LOAD SERVED LOAD SERVED FACTOR LOAD (VA) NO. 1 20 1 1385 1.25 CHANDELIER DM-1 A DINING AREA EM LIGHTS 1.25 200 1 20 2 3 20 1 240 1.25 LIGHTS DM-2 E PARKING LOT LIGHTS 1.25 1000 1 20 4 5 20 1 369 1.25 LIGHTS DM-3 CC PARKING LOT LIGHTS 1.25 1000 1 20 6 7 20 1 850 1.25 RESTROOM LIGHTING GROUND LIGHTS 1.25 360 1 20 8 9 20 1 1604 1.25 KITCHEN LIGHTING 1.3 BUILDING LIGHTS 1.25 402 1 20 10 11 20 1 196 1.25 ROOF LIGHTS . LIGHTED BUILDING SIGN 1.25 1500 1 20 12 13 20 1 600 1.00 OUTDOOR RECEPT A LIGHTED BUILDING SIGN 1.25 1500 1 20 14 15 20 1 400 1.00 IRRIGATION SYSTEM ' BUILDING SECURITY LIGHTS 1.25 230 1 20 16 17 20 1 .1200 1.00 SOUND SYSTEM C PATIO FANS 1.00 800 1 20 18 19 20 1 1440 1.00 BOOTH & TV RECEPT A MERCH CABINET RECEPT 1.00 500 1 20 20 21 20 1 1440 1.00 BOOTH & TV RECEPT 8 MISC. DINING RECEPT 1.00 1000 1 20 22 23 20 1 400 1.00 TTB 'C MISC. DINING RECEPT 1.00 800 1 20 24 25 20 1 600 1.00 FACP ;^. RESTROOM RECEPT 1.00 800 1 20 26 27 20 1 200 1.00 SECURITY PANEL OUTDOOR PATIO RECEPT 1.00 1000 1 20 28 29 20 1 200 1.00 MARLIN CONTROL PANEL C. SOUND SYSTEM 1.00 1200 1 20 30 31 20 1 1880 1.00 AIR CURTAINS /. AIR CURTAINS 1.00 1880 1 20 32 33 20 1 1 100 1.00 BOOTH & TV RECEPT B FIRE PIT CONTROL & EF 1.00 400 1 20 34 35 20 1 1200 1.00 SOUND SYSTEM i_ INFRARED HEATER CNTL 1.00 700 1 20 36 37 20 3 1000 1.00 EUH-1 ,. MOTO. INSECT SCREENS 1.00 600 1 20 38 39 20 3 1000 1.00 EUH-1 B MOTO. INSECT SCREENS 1.00 600 1 20 40 41 20 3 1000 1.00 EUH-1 C RECIRC PUMP 1.00 400 1 20 42 43 20 1 250 1.25 LED ROPE LIGHTS A LIGHTING DM-4 1.25 117 1 20 44 45 20 1 800 1.00 RECEPTION RECEPT _ LIGHTING DM-5 1.25 99 1 20 46 47 20 1 1200 1.00 SOUND SYSTEM C. LIGHTING DM-6 1.25 243 1 20 48 49 15 1 696 1.00 EF-7 .. LIGHTING DM-7 1.25 144 1 20 50 51 20 1 SPARE b LIGHTING DM-8 1.25 95 1 20 52 53 20 1 SPARE C LIGHTING DM-9 1.25 45 1 20 54 55 20 1 SPARE A LIGHTING DM-10 1.25 77 1 20 56 57 20 1 SPARE _< LIGHTING DM-11 1.25 288 1 20 58 59 20 1 SPARE i LIGHTING DM-12 1.25 105 1 20 60 CONNECTED LOAD: DEMAND LOAD: PHASE A (VA): 14,879 PHASE A (VA): 16,100 PHASE B (VA): 11,898 PHASE B (VA): 12,888 PHASE C (VA): 12,558 PHASE C (VA): 13,423 TOTAL LOAD (VA): 39,335 TOTAL DEMAND LOAD (VA): 42,410 117.72 A NOTES: 1. PANEL SCHEDULE: C November 16, 2015 PROJECT: Twin Peaks - Washington VOLTAGE L-L: 208 LOCATION: Electrical room VOLTAGE L-G: 120 JOB NO.: 15-120 SYSTEM: 30, 4-WIRE COMMENTS: New Nema 1 Panel BUS RATING: 225A S.C.RMS RATING: 42,000 AIC MAIN O.C. DEVICE: MLO MOUNTING: Surface CIR CIRCUIT BREAKER CONNECTED NEC DEMAND DESCRIPTION OF PHASE DESCRIPTION OF NEC DEMAND CONNECTED CIRCUIT BREAKER CIR AMPS POLE POLE AMPS NO. LOAD (VA) FACTOR LOAD SERVED LOAD SERVED FACTOR LOAD (VA) NO. 1 20 1 400 1.00 E061 POS RECEPT A FLAT SCREEN TV RECEPTS 1.00 1200 1 20 2 3 20 1 400 1.00 E061 POS RECEPT B FLAT SCREEN TV RECEPTS 1.00 1200 1 20 4 5 20 1 400 1.00 E061 POS RECEPT C FLAT SCREEN TV RECEPTS 1.00 1200 1 20 6 7 20 1 600 1.00 E061 C POS PRINTER RECEPT A FLAT SCREEN TV RECEPTS 1.00 1200 1 20 8 9 20 1 400 1.00 E075 POS RECEPT ... FLAT SCREEN TV RECEPTS 1.00 1200 1 20 10 11 20 1 400 1.00 E075 POS RECEPT r_ FLAT SCREEN TV RECEPTS 1.00. 1200 1 20 12 13 20 1 400 1.00 E075 POS RECEPT A FLAT SCREEN TV RECEPTS 1.00 1000 1 20 14 15 20 1 400 1.00 E075 POS RECEPT '^s FLAT SCREEN TV RECEPTS 1.00 1000 1 20 16 17 20 1 400 1.00 E075 POS RECEPT C FLAT SCREEN TV RECEPTS 1.00 1000 1 20 18 19 20 1 400 1.00 E075 POS RECEPT A FLAT SCREEN TV RECEPTS 1.00 1000 1 20 20 21 20 1 400 1.00 E075A POS RECEPT : FLAT SCREEN TV RECEPTS 1.00 1500 1 20 22 23 20 1 400 1.00 E075A POS RECEPT C FLAT SCREEN TV RECEPTS 1.00 1000 1 20 24 25 20 1 400 1.00 E093 BAR PRINTER :; FLAT SCREEN TV RECEPTS 1.00 1000 1 20 26 27 20 1 400 1.00 E075 POS RECEPT 3 FLAT SCREEN TV RECEPTS 1.00 1000 1 20 28 29 15 1 696 1.00 EF-6 C FLAT SCREEN TV RECEPTS 1.00 1000 1 20 30 31 20 1 1000 1.00 UNDER COUNTER PLUGMOLD A FLAT SCREEN TV RECEPTS 1.00 1500 1 20 32 33 20 1 1600 1.00 UNDER COUNTER PLUGMOLD B MANAGER'S OFFICE RECEPTS 1.00 800 1 20 34 35 20 1 800 1.00 UNDER BAR PLUGMOLD C MANAGER'S OFFICE RECEPTS 1.00 800 1 20 36 37 20 1 800 1.00 UNDER BAR PLUGMOLD , . BUSSED SPACE 38 39 20 1 800 1.00 PLUGMOLD @ GREEN ROOM B BUSSED SPACE 40 41 20 1 400 1.00 RECEPTS IN GREEN ROOM C_ BUSSED SPACE 42 CONNECTED LOAD: DEMAND LOAD: PHASE A (VA): 10,900 PHASE A (VA): 10,900 PHASE B (VA): 11,100 PHASE B (VA): 11,100 PHASE C (VA): 9,696 PHASE C (VA): 9,696 TOTAL LOAD (VA): 31,696 TOTAL DEMAND LOAD (VA): 31,696 87.98 A NOTES: 1. DEC 17 2015 City Of-TUila BUILDING DIVISION T E., ` ;; L A NOV 2 0 2015 PERMIT CENTER DF=SIGNPARAMC-T9RS. LLC 6373 SILVER STR-EAM LN �RISCO. TX 75034 PI -I: 214.784.5014 �X: 303.223.gI O4 DQSIGNPARAMQTRS.COM John Tinsley, P.E. 38140 Fawn Meadows Tr. Elizabeth, Colorado 80707 Phone: 303.646.1860 Fax: 303.646.5623 : r START DATE • DILM0116 PROJECT NO • i1NM DRAWN BY CHECKED BY ISSUEDIIREVISED • • DATE PERNT 11.13=5 EXPIRES: 11115/2017 EQUIPMENT SCHEDULES ! I 1f��; 7 3! :i •i' C0PMQKTG10WU15 KITCHEN EQUIPMENT SCHEDULE October 30, 2015 DESCRIPTION QTY. LOAD VOLTS 0 BRANCH CKT. COND. CIRCUIT CONNECTION NOTES HP,KW,FLA RECEPT. DISC. J-BOX CONDUCTORS K3 44" LOW TEMP DISH MACHINE 48.75A 208 3 4#6,#1 OG 1.. VERIFY 5'-0" K10 ICE MAKER 1.1A 120 1 2#10,#10G 3/4" VERIFY 7-3" K11 ICE MAKER REMOTE CONDENSER 8.3A 208 3 4#10,#IOG 3/4" VERIFY ROOF K13 BAG-N-BOX SODA SYSTEM l0A 120 1 2#10,#10G 3/4" VERIFY 6'-6" K14 COOLER/FREEZER VAULT 7A 120 1 2#10,#10G 3/4" VERIFY 10'-0 K15 FREEZER VAULT REMOTE REFRIG 3.5HP 208 3 4#10,#10G 3/4" VERIFY ROOF K16 FREEZER VAULT BLOWER COIL 120 1 2#10,#1 OG 3/4" K17 GEN. COOLER VAULT REMOTE REFRIG 2HP 208 3 4#10,#10G 3/4" VERIFY ROOF K18 GEN. COOLER VAULT BLOWER COIL 2#10,#1 OG 3/4" K19 ICE MAKER 1.1A 120 1 2#10,#10G 3/4" VERIFY T-3" K28 PREP REFRIGERATOR 7.9A 120 1 i 2#10,#10G 3/4" VERIFY 16" K30 75 LBS FRYERS 3A 120 1 2#10,#10G 3/4" VERIFY 16" K32 CONVEYOR TOASTER 13.4A 208 1 3#10,#1 OG 3/4" VERIFY 2.78 kW 4'-2" K35 EQUIPMENT STAND WITH DRAWERS 9.5A 120 1 2#10,#1 OG 3/4" VERIFY 16" 35.1 EQUIPMENT STAND WITH DRAWERS U 120 1 2#10,#1 OG 3/4" VERIFY 16" K40 EQUIPMENT STAND WITH DRAWERS 4.8A 120 1 2#10,#10G 3/4" VERIFY 16" K42 1000 WATT MICROWAVE OVEN 13A 120 1 2#10,#10G 3/4" VERIFY 6'-6" K44 NITROGEN SYSTEM FOR DRAFT BEER 1 OA 120 1 2#10,#10G 3/4" VERIFY 24" K45 PAN RAIL REFRIGERATOR 7.9A 120 1 2#10,#10G 3/4" VERIFY 16" K47 FOUR WELL HOT FOOD COUTNER 20A 208 1 3#10,#10G 3/4" VERIFY 16" K49 PAN RAIL REFRIGERATOR 7.9A 120 1 2#10,#1 OG 3/4" VERIFY 16' K51 BACK PREP EXHAUST HOOD 2#10,#1 OG 3/4" VERIFY 10'-6" 51.1 UPBLAST EXHAUST BLOWER 17.3A 208 1 3#10,#1 OG 3/4" VERIFY K52 CHEESE MELTER 17.3A 208 1 3#10,#1 OG 3/4" VERIFY 6'-6" K54 TEA BREWER & URNS 13A 120/20E 1 3#10,#1 OG 3/4" VERIFY 4'-2" K56 DROP -IN ICE AND SODA STATION l0A 120 1 2#10,#1 OG 3/4" VERIFY 12" K60 SANDWICH UNIT 8.3A 120 1 2#10,#10G 3/4" VERIFY 16" K61 C ORDER PRINTER (DED. CIRCUIT) 15A 120 1 2#10,#10G 3/4" VERIFY 5-0" K62 SUPPORT COUNTER 100A 20/20 3 4#1,#6G 1-1/2" VERIFY 18" K65 MANAGERS DESK AND WALL SHELVES 120 1 2#10,#10G 3/4" K66 TWO TRUNK REMOTE BEER SYSTEM 40A 208 3 4#8,#1 OG 1" VERIFY ROOF K67 BEER COOLER VAULT I OA 120 1 2#10,#1 OG 3/4" VERIFY 10'-0" K68 BEER COOLER REMOTE REFRIG. UNIT 3HP 208 3 4#10,#1 OG 3/4" VERIFY ROOF K69 BEER COOLER BLOWER COIL 2#10,#1 OG 3/4" K75 POS REGISTER (DED. CIRCUIT) 1 OA 120 1 2#10,#1 OG 3/4" VERIFY 16" K75A POS REGISTER (DED. CIRCUIT) 1 OA 120 1 2#10,#1 OG 3/4" VERIFY 6" K79 SLIDE TOP MUG FROSTER 7.6A 120 1 2#10,#1 OG 3/4" VERIFY 16" K80 COOLER W/ 2" CASTER SET 7A 120 1 2#10,#1 OG 3/4" VERIFY 16" K81 MAIN COOK LINE EXHAUST HOOD 2#10,#1 OG 3/4" VERIFY 10'-6" 81.1 UPBLAST EXHAUST BLOWER 6.8A 208 3 4#10,#1 OG 3/4" VERIFY 2HP ROOF 81.2 UPBLAST EXHAUST BLOWER 4.5A 208 3 4#10,#1 OG 3/4" VERIFY 1.5HP ROOF 81.3 MAKE-UP AIR SYSTEM 15A 208 3 4#10,#1 OG 3/4" VERIFY 3HP ROOF K88 HEAT STRIP 5.2A 120 1 2#10,#10G 3/4" VERIFY 4'-2" K89 HEAT STRIP 5.2A 120 1 2#10,#10G 3/4" VERIFY 4'-2" K90 FIRE SUPPRESSION SYSTEM 2#10,#10G 3/4" K93 SERVICE WELL PRINTER (DED. CIRCUIT) 120 1 2#10,#1 OG 3/4" VERIFY 38" K94 SODA GUN PLATFORMS 5A 120 1 2#10,#10G 3/4" VERIFY 12" K103 DISH MACHINE EXHAUST HOOD 2#10,#10G 3/4" 103. UPBLAST EXHAUST BLOWER 4.1A 120 1 2#10,#1 OG 3/4" VERIFY .33HP ROOF K104 BUILT-IN TWO DRAWER WARMER 7.5A 120 1 2#10,#I OG 3/4" VERIFY 12" K107 TWO DOOR REFRIGERATOR 5.8A 120 1 2#10,#1 OG 3/4" VERIFY 33HP 12" K109 DELIVERY DOOR FLY FAN 5.1A 120 1 2#10,#1 OG 3/4" VERIFY 7'-6" K114 MUG FROSTIER W/ 2" CASTER SET 5.8A 120 1 2#10,#1 OG 3/4" VERIFY 16" K115 MOBILE COOK & HOLD CABINET 16A 120 1 2#10,#10G 3/4" VERIFY 16" K719 DISH MACHINE EXHAUST HOOD 2#10,#10G 3/4" VERIFY 5-0" 119. UPBLAST EXHAUST BLOWER 4.1A 120 1 2#10,#1 OG 3/4" VERIFY .33HP ROOF K120 HIGH TEMP DISH MACHINE 46.8A 208 3 4#6,#IOG 1" VERIFY 24" K123 DROP -IN ICE CREAM FREEZER 5.8A 120 1 2#10,#1 OG 3/4" VERIFY 16" K125 HOT FOOD WELL 13.75A 120 1 2#10,#10G 3/4" VERIFY 16" FP 2#10,#10G 3/4" VERIFY 4'-0" NOTES: 1. Field verify device locations and mounting heights and equipment requirements with provider prior to rough -in. Field verify outlet, J-Box or hardwire, number of wires, wire and circuit size requirements with provider prior to rough -in. 2. Equipment numbers coordinate with Equipment Schedule on Architectural/Kitchen drawings, reference for additional information. 3. All outlets serving equipment designated with NEMA 5-15 plugs shall be 20A duplex receptacles on a 20A branch circuit breaker in In accordance with NEC 210.21(13)(3) and shall be GFI per NEC 210.8(B). 4. Notes 1-3 apply to all equipment. 5. All raceways in millwork shall be run concealed from view. 6. POS EQUIPMENT - Provide dedicated IG circuit with dedicated neutral and ground and data raceways - field verify requirements and additional scope of work with provider. Feeder Schedule - Cu I Based on NEC: 2014 Feeder Schedule - AI I Based on NEC: 2014 3000/W 8[W-500kcmil, 3/OG, 3-1/2"C] 3000/W 14[W-350kcmil, 3"C] 2000/W 6[W-400kcmil, 3/OG, 3"C] 2000/W 7[W-500kcmil, 400kcmil G, 3-1/2"C] 1600/W 5[W-400kcmil, 3/OG, 3"C] 1600/W 8[W-250kcmil, 250kcmi]G, 3"C] 1200/W 4[W-350kcmil, 3/OG, 3"C] 1200/W 4[W-500kcmil, 250kcmil G, 3-1/2"C] 1000/W 3[W-400kcmil, 2/OG, 3"C] 1000/W 4[W-350kcmil, 4/OG, 3"C] 800/W 3[W-300kcmil, 1/OG, 3"C] 800/W 3[W-400kcmil, 3/OG, 3"C] 750/W 3[W-250kcmil, 1/OG, 3"C] 750/W 3[W-350kcmil, 2/OG, 3"C] 600/W 2[W-350kcmil, #1G, 3"C] 600/W 2[W-500kcmil, 2/OG, 3-1/2"C] 500/W 2[W-250kcmil, #2G, 3"C] 500/W 2[W-350kcmil, 1/OG, 3"C] 400/W 2[W-3/0, #3G, 2"C] 400/W 2[W-250kcmil, #1G, 3"C] 350/W 2[W-2/0, #3G, 2"C] 350/W 2[W-4/0, #2G, 2-1/2"C] 300/W W-350kcmil, #4G, 3"C 300/W W-500kcmil, #2G, 3-1/2"C 250/W W-250kcmil, #4G, 3"C 250/W W-350kcmil, #4G, 3"C 225/W W-4/0, #4G, 2"C 225/W W-300kcmil, #4G, 3"C 200/W W-3/0, #6G, 2"C 200/W W-250kcmil, #4G, 2-1/2"C 175/W W-2/0, #6G, 2"C 175/W W-4/0, #6G, 2"C 150/W W-1/0, #6G, 2"C 150/W W-3/0, #6G, 2"C 125/W W-1/0, #6G, 2"C 125/W W-2/0, #6G, 2"C 110/W W#1, #6G, 1-1/2"C 11O/W W-2/0, #6G, 2"C 100/W W# 1, #6G, 1-1 /2"C 100/W W-1 /0, #6G, 2"C 90/W W#2, #8G, 1-1 /4"C 90/W W-1 /0, #6G, 2"C 80/W W#3, #8G, 1-1 /4"C 80/W W# 1, #8G, 1-1 /2"C 70/W W#4, #8G, 1-1 /4"C 70/W W#2, #8G, 1-1 /4"C 60/W W#4, #8G, 1-1 /4"C 60/W W#2, #8G, 1-1 /4"C 50/W W#6, # 1 OG, 1 "C 50/W W#4, #8G, 1-1 /4"C 40/W W#8, #1OG, 1 " C 40/W W#6, #8G, 1" C 30/W W#10, #1OG, 3/4"C 30/W W#8, #1 OG, 3/4"C 20/W W# 12, # 12G, 3/4"C 20/W W# 10, # 1 OG, 3/4"C This table indicates minimum conductor size for feeders This table indicates minimum conductor size for feeders of the ampacity indicated where #/W indicates the of the ampacity indicated where #/W indicates the ampacity/ numbers of wire. A #S/W indicates no ground. ampacity/ numbers of wire. A #S/W indicates no ground. Service Ground Table Equipment Ground Table Service Ground Table Equipment Ground Table 150G #6 20EG #12 150G #4 20EG #10 20OG #4 60EG #10 20OG #2 60EG #8 30OG #2 1 OOEG #8 30OG 1 /0 1 OOEG #6 50OG 1 /0 200EG #6 50OG 3/0 200EG #4 80OG 2/0 300EG #4 1000G 4/0 300EG #2 >80OG 3/0 400EG #3 >1000G 250 400EG #1 The service ground chart indicates the minimum service The service ground chart indicates the minimum service ground based on #G where # is the ampacity from the ground based on #G where # is the ampacity from the chart above, and the equipment ground chart indicates the chart above, and the equipment ground chart indicates the minimum equipment grounding conductor size #EG where minimum equipment grounding conductor size #EG where # is the rating/ setting of the overcurrent device protecting # is the rating/ setting of the overcurrent device protecting the conductors and equipment. the conductors and equipment. All conductors shall be Copper. All conductors shall be ALUMINUM Where discrepancies occur between the Feeder schedule Where discrepancies occur between the Feeder schedule and the grounding charts, the chart shall overrule the and the grounding charts, the chart shall overrule the feeder schedule and the NEC shall overrule all schedules. feeder schedule and the NEC shall overrule all schedules. The master electrician shall be responsible for ensuring The master electrician shall be responsible for ensuring that no feeders or branch circuits are installed in a manner that no feeders or branch circuits are installed in a manner or sized in such a way as to violate the NEC. or sized in such a way as to violate the NEC. Ampacities are based on NEC table 310.15(B)(16) Ampacities are based on NEC table 310.15(B)(16) utilizing the 60 degree column up to 100 Amps and the utilizing the 60 degree column up to 100 Amps and the 75 degree column above 100 Amps Service ground 75 degree column above 100 Amps Service ground conductor sizes are per NEC table 250.66 and conductor sizes are per NEC table 250.66 and equipment ground is per NEC table 250.122. equipment ground is per NEC table 250.122. Transformer Schedulel Based on NEC: 2014 Overcurrent Overcurrent Protection Protection 48OV, 30 kVA - Ground 208V, 30 20A 15 - #8 50A 50A 30 - #6 100A 70A 45 - #6 150A 125A 75 - #2 250A 175A 112.5 - #2 400A 225A 150 - 1 /0 500A 350A 225 - 2/0 800A Notes: Primary shall be 3-wire and secondary shall be 4-wire unless noted otherwise. All transformers 45kVA and below shall be suspended unless noted otherwise. All transformers over 45kVA shall be floor mounted unless noted otherwise. Primary and secondary feeders shall be sized per the circuit breaker size and shall be 3-wire on the primary and 4-wire on the secondary. For example all 45kVA 480/208V transformers with a 480V primary will be fed with a 70/3 on the primary and a 150/4 on the secondary (the bonding and grounding shall be per NEC 250.30A). FIRE ALARM SYSTEM NOTES FIRE ALARM SYSTEM IS TO BE DESIGN/BUILD BY THE CONTRACTOR. REFRIGERATION - COND. UNIT ON ROOF. OFUSED W.P. DISCONNECT SWITCH O GFI/WP RECEPTACLE INDEPENDENT, GALVANIZED UNISTRUT SUPPORT REFRIGERATOR COND. UNIT DETAIL SCALE: NTS PANEL M PANEL C MAIN BONDING JUM SIZE PER 250- SIZE PER ART 250-66 #31 CU CADWELD 3/4" x 10' � GRROUND ROD (MIN. 6' APART) 20'-0" MIN. OF 1 /2" 1` REBAR IN BUILDING FOOTING (WHERE AVAILABL WATER SERVICE #3 Cow CADWELD SUPPLY SIDE VALVE, METER OR UNION JUMPER GROUNDING DETAIL SCALE: NTS SIZE PER .� TABLE (TYP) ZE PER ART 250-102 ----i EQUIPMENT BONDING JUMPER CADWELD BUILDING STRUCTURAL STEEL GROUND CLAMP UL APPROVED RTU-1 RTU-2 RTU-3 RTU-4 M UTILITY 200/4 200/4 200/4 200/4 200/4 200/4 200/4 200/4 METER PAD MOUNTED UTILITY 200A/3P 20OA/3P 200A/3P 20OA/3P 20OA/3P 20OA/3P 20OA/3P 20OA/3P 500kV`A TRANSFORMER 1600A/3P 200A JJN 200A AN 200A AN 200A AN 200A AN 200A AN 200A AN 200A AN 208/120V, 3-PHASE, 4W 1600KRP MDP 1600A 208/120V, 3PHASE,4W, N T65KAIC G >800G GRADE LEVEL 16005/4 BOND AND GROUND PER NEC 250 • COLD WATER PIPE • UFER ONE LINE D I AG RAM - . BUILDING STEEL 1 • GROUND ROD LUMINAIRE SCHEDULE November 16, 2015 KEY DESCRIPTION MFR. & CAT.NO. LAMP WATTAGE VOLTS MOUNTING NOTE INFORMATION LF-01 MR 16 DOWNLIGHT ELITE TCP-LED7MR 7W LED 120V 10'-0" BAR/SOFFIT AT BAR BL 4-20W-M-120-AT-W 627KNFL 9'-0" RESTROOMS F-01 G PAR20 DOWNLIGHT ELITE TCP-LED9E26P2027 9W LED 120V 9'-0 BOOTH SOFFIT B4-20-AT-W-1 OW KNFLB LF-02 PAR 20 TRACK HEAD JUNO TCP-LED9E26P2027 9W LED 120V REF: ARCH. RCP (TRACK OR MONOPOINT T326B-BL - 120V BLACK KNFLB LF-03 MOOSE ANTLER PENDANT LAMP PLUS IMP (12)12W 240W 120V 8'-10" 33981 - 12LT ELK LF-04 EXTERIOR GROUND MONTED UP LIGHT COOPER LIGHTING LED 1 OW 120V LENS FLUSH LUMIERE W/GRADE LF-05 ELK ANTLER PENDANT VAXCEL IMP (6)20W 120W 120V 8'-10" 891035S - RUSTIC CANDELABRA LF-07 PASADENA BEAR SCONCE EDGELINE DESIGNS TRAIL 18W WARM WHITE 18W LED 120V 7-0" E26 2700K LF-08 MR16 SPOT LIGHT ON 12V TRACK JUNO TCP-LED7MR 7W LED 120V 9'-3" TO CENTER TL191 BL TYPE B BLACK 627KNFRL OF TRACK LF-11 EXTEIOR WALL MOUNTED SECURITY LIGHT RAB COMPACT FLUORESCENT WP2CF32-El-BL 32W FLUOR. 120V VARIES LF-13 2x4 FLOURESCENT TEXF-1 31 -A228MV & SAME W/ EL 2-F28T5SP35 F28 T5 FLUOR. 120V 9'-0" KITCHEN / BOH LF-14 EXTERIOR ENTRY LIGHT IN TRUSS/ROOF LIGHTS LITHONIA LED 14W LED 120V 16-6" 0FLR-6LC-120-P-BZ LF-20 VANITY MAKE-UP LIGHTS KICHLER VANITY LIGHT BY OWNER (6) 60W 120V 8'-6" TO CL BRUSHED NICKEL - 623NI MAX LF-21 WALK-IN COOLER LIGHTS TXFL-KDS-228-MV 2-F28T5SP41 F28 T5 FLUOR. 120V LF-L I LED ROPE LIGHT UNDER BAR COUNTER AMRICAN LTG LED 3000K .77W/FT 120V ULRL-LED-UVW-XX LF-Xl EXIT/EMERGENCY COMBO IN LED 5W LED 120V 8'-6" MIN TCP-20723 BL LF-X2 INTERIOR EMERGENCY LAMPS WITH UNIT 5W LED 120V TCP-20760 BL LF-X3 EXTERIOR EMERGENCY LAMP LAMPS WITH UNIT 5W LED 120V DAMP EXIT-TR-WB-BL LF-X4 EXIT/EMERGENCY COMBO LAMPS WITH UNIT 6W LED 120V DAMP ELITE-TR-WB-BL LF-X5 EXTERIOR WET LOCATION EMERGENCY LIGHT LIGHTOLIER 1) 2PIN13W-TT-3500 26W FLUOR. 120V #01-EM-C-B-1 Tl TRACK SECTION 120V JUNO 120V REF: ARCH. RCP T6BL T2 TRACK SECTION, 12V 1TL8BL JUNO 12V 9'-3" TO CL OF TRACK NOTES: (Notes apply to all fixtures where applicable) 1. EMERGENCY FIXTURES - All Fixtures Indicated as Emergency shall be provided with a 90-Minute Battery Pack and all Fluorescent Fixtures indicated as Emergency shall be provided with a 1300 Lumen, 90-Minute Battery Pack. 2. VERIFY VOLTAGES - The E.C. shall verify voltages on drawings prior to ordering or any work, the engineer shall be notified of any descrepancies in the voltage of the circuiting on the drawings and the luminiare schedule prior to any purchase or work. 3. VERIFY LAMPING - The E.C. shall verify lamping with the manufacturer prior to ordering and notify the engineer of any lamping descrepancies. 4. PROVIDE A COMPLETE INSTALLATION - The E.C. shall provide all labor and material to provide a complete and functional system per the design intent as dictated by the switching type and location (including dimmer switches and compatible ballasts or transformers), ceiling type and location, circuiting, voltages, and lamping types. 5. BALLAST DISCONNECT - All electric discharge luminaires shall comply with 2008 nec 410.130 and shall have a means of disconnect for the ballast. 6. DUAL LEVEL SWITCHING - For fixtures with more than one switch designation shown on plans provide fixtures with additional ballasts for dual level light control by separate switching of inboard and outboard lamps as required to conform to IECC Requirements. 7. FOOD PREP AREAS - Provide shatter -resistant lamps or provide clear lenses on all fixtures located above all kitchen areas. SCALE: NTS ONE LINE DIAGRAM GENERAL NOTES: 1. E.C. TO FIELD VERIFY EXISTING CONDITIONS 2. ALL EQUIPMENT IS NEW UNLESS NOTED AS EXISTING (E). 3. ALL EXTERIOR EQUIPMENT TO BE WEATHERPROOF 4. FIELD VERIFY INSTALLATION REQUIREMENTS WITH UTILITY CO. PRIOR TO ANY ROUGH -IN. 5. SERVICE EQUIPMENT SHALL BE LEGIBLY MARKED IN THE FIELD WITH THE MAXIMUM AVAILABLE FAULT CURRENT. THE FIELD MARKINGS SHALL INCLUDE THE DATE THE FAULT CURRENT CALCULATION WAS PERFORMED AND BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED, PER 2014 NEC 110.24 (A) EQUIPMENT SCHEDULE November 13, 2015 KEY EQUIPMENT LOAD VOLTS 0 BRANCH CKT. CONDUIT DISCONNECT CIRCUIT NOTES CONDUCTORS HP,KW,FLA SWITCH FUSE RTU-1 ROOFTOP HEAT PUMP 194 MCA 208 3 4-3/0,#6G 2" 20OA/3P MDP-5 1 12.5-TON 200 MOCP WP RTU-2 ROOFTOP HEAT PUMP 194 MCA 208 3 4-3/0,#6G 2" 20OA/3P MDP-6 1 12.5-TON 200 MOCP WP RTU-3 ROOFTOP HEAT PUMP 194 MCA 208 3 4-3/0,#6G 2" 20OA/3P MDP-7 1 12.5-TON 200 MOCP WP RTU-4 ROOFTOP HEAT PUMP 194 MCA 208 3 4-3/0,#6G 2" 20OA/3P MDP-8 1 12.5-TON 200 MOCP WP MUA-1 MAKE-UP AIR UNIT 5HP 208. 3 4#10,#10G 3/4" 30A/3P M-20,22,24 1 WP KEF-1 EXHAUST FAN 0.5HP 208 3 4#12,#12G 3/4" 15A/3P M-25,27,29 1,2 WP KEF-2 EXHAUST FAN 2HP 208 3 4#12,#12G 3/4" 15A/3P M-31,33,35 1,2 WP KEF-3 EXHAUST FAN 1.5HP 208 3 4#12,#12G 3/4" 15A/3P M-37,39,41 1,2 WP KEF-4 EXHAUST FAN 1/3HP 120 1 2#12,#12G 3/4" 15A/1P M-21 1,2 WP KEF-5 EXHAUST FAN 1/3HP 120 1 2#12,#12G 3/4" 15A/1P M-23 1,2 WP EF-6 EXHAUST FAN 1/4HP 120 1 2#12,#12G 3/4" Sto . NA C-29 1,2 EF-7 EXHAUST FAN 1/4HP 120 1 2#12,#12G 3/4" Sto NA B-49 1,2 EF-8 EXHAUST FAN 48W 120 1 2#12,#12G 3/4" Sto NA 1,2 EUH-1 ELECTRIC UNIT HEATER 3KW 208 3 4#12,#12G 3/4" 15A/1 P NA 1,2 NOTES: 1. Field verify final location and electrical requirements of all equipment with provider prior to rough -in. 2. Provide line voltage controls and wiring as required. Field verify control requirements with provider. 3. Provide HACR breakers for all circuits serving equipment. FAULT CURRENT CALCULATION TABLE November 16, 2015 LOCATION (n) # of RUNS CONDUCTOR VOLTAGE L(ft) C f M F 500 Utility Transformer 208 77,100 1600A MDP 5 400 208 100 24,297 0.53 0.65 50,463 Panel M 1 3/0 208 20 12,844 0.65 0.60 30,518 Panel B 1 3/0 208 20 12,844 0.65 0.60 30,518 Panel C 1 3/0 208 20 12,844 0.65 0.60 30,518 Panel K 1 3/0 208 20 12,844 0.65 0.60 30,518 NOTES: 1. All Calculations use Bussman "Point -To -Point" Method. 2. Variables: L=Feeder Length (LF) C= Conductor "C" Value M(n) =1 _ (1+f(n)) f(n) = (1.73 x L x F(n-1))/(C x # of runs x Voltage) in Amperes F(n)=F(n-1) x M(n) 3. The E.C. shall report any discrepancies to the Engineer. 4. Aluminum Conductors, MC Cabling, and Series Rated Panels are not allowed. 5. The E.C. shall verify the Available Fault Current from the Electrical Utility and shall report the actual Fault Current available to the Engineer if different from shown. Fault Currents are based on Utility information or %Z=1.4 if none are provided. 6. The E.C. shall field verify the Feeder Lengths and report any discrepancy to the engineer. Conductor Lengths listed in this table are engineering estimates and are not intended to represent actual lengths for bidding or other calculations. The E.C. shall inform the Engineer immediately if the actual lengths are less than that listed. REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC DEC 17 2015 City of-TukWila, NOV 2 0 2015 �"LE= VIJTCENTEFL DQSIGNPARAMQTCRS, LLC 6373 SILVI-R STRI=AM LN �RISCO. TX 75034 PI -I: 214.784.5014 �X: 303.223.9104 DQSIGNPARAM ETQRS.COM John Tinsley, P.E. 38140 Fawn Meadows Tr. Elizabeth, Colorado 80107 Phone: 303.646. 7 860 Fax: 303.646.5623 u4 f 4 • 1 START DATE • oaaaaal6 PROJECT NO • TwPot DRAWN BY CHECKED BY - ISSUEMEVISED • • DATE PERLUT 111.1132111115 P-,,F-1 CIC ?, WASk f j O� 412 CISTBR Gti� SSIONAL EXPIRES: 11115/2017 PANEL SCHEDULES 3mO2 ro"WeNToammtE