Loading...
HomeMy WebLinkAboutPermit EL15-1028 - BUI RESIDENCE - SOLAR PANELHENRY BUI 1442658 TH AVE s EL15-1028 City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: htti)://www.TukwilaWA.gov Parcel No: 3365901214 Address: 14426 58TH AVE S Project Name: HENRY BUI ELECTRICAL PERMIT Permit Number: EL15-1028 Issue Date: 12/7/2015 Permit Expires On: 6/4/2016 Owner: Name: BUI HENRY PHUONG+LE CHRISTI Address: 14426 58TH AVE S , TUKWILA, WA, 98168 Contact Person: Name: AMY BEAUDOIN Phone: (206) 261-6654 Address: 692134 AVE SW, SEATTLE, WA, 98126 Contractor: Name: WEST SEATTLE NATRL ENERGY LLC Phone: (206) 459-8442 Address: 692134 AVE SW, SEATTLE, WA, 98126 License No: WESTSSN907NB Expiration Date: 8/4/2016 Lender: Name: Address: DESCRIPTION OF WORK: Electric for solar INSTALL A 30 PANEL SOLAR PV ARRAY ON ROOF THROUGH A DEDICATED 50 AMP BREAKER. REPLACE EXISTING BREAKER PANEL WITH A CH42-225 SOLAR READY PANEL AND AN INTEGRATED MANUAL GENERATOR OVERRIDE LOCK Valuation of single family: $4,000.00 Fees Collected: $181.54 Valuation of mf/comm: $0.00 Type of Work: ADDITION Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 c I) Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: '�Date: YL-1'1-5 Print Name: axYxA 1&CLUA0i ✓\ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKW. 1 Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://xvww.TukwilaWA.gov SITE LOCATION Electrical Permit No.� 1 �� Project No. Date Application Accepted: Date Application .Expires: use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" King Co Assessor's Tax No.: 33110540121 y Site Address: 14LI 2b 510M owt S Suite Number: Floor: Tenant Name: tlenry Fair, New Tenant: ❑ ..... Yes W.. No PROPERTY OWNER Name: KW b&M Address: shy` City: State: Zip: CONTACT PERSON — person receiving all project communication Name: (il1M $eQAA0�01n — Wc�1�E Address: (oqL% 3'-1 QVt sv1 City: �Q State: Zip: CjJb%, „(o Phone: �,(� , 2{0 (obSy Fax: U6- 21L4-ygb2 Email: 0.�r1n 9t�1+eStSertl�}1ttJa�t►Ya\E r;rorM Valuation of Project (contractor's bid price): $ 4 iMcp ELECTRICAL CONTRACTOR INFORMATION Company Name: uJeSA Sft*oNa�,wYal Address: �Oq2\ 3yjM 0.ve sW City: sft+ c State: U3, Zip: Q%bl Phone: 2Z6-4Sq_gyy2 Fax:JM,2Z6_27y,4q(o2 Contr Reg No.: W WN 9.7N$ Exp Date: BAS/1 b Tukwila Business License No.; Scope of Work (please provide detailed information): 1y%Sk4.\I A 30 %&*A W&V 9V ArrQy On Q*41 4)nn " a drdk�m�e SO ann p bf mVw . 1Rep\ace e c isiAIN breaker prune! t smq a G1Aq,L- 21's So\Ca gtaA. Palf4 and can ZfkA AC& OUJA% O-k ot�c�r O�ity'�iciQ. Ioc,K . Will service be altered? ❑ Yes [A No Adding more than 50 amps? ❑ Yes ® No Type of Use: lJ►A6J i101n ka e�Cd s, i 04 Type of work: ❑ New Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: J9 Puget Sound Energy ❑ Seattle City Light H:Wpplications\Forms-Applications On Line12014 ApplicationsTlectrical Permit Application Revised 1-1-14.docx Revised: July 2013 hh Pagel of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings...................................$152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat).................................$59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration.......................................$81.90 (no added/altered circuits) Service change with added/altered circuits.................$81.90 _ number of added circuits .......................$11.55 ea ❑ Circuits added/altered without service change ............ $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ............ $54.60 (6 or more circuits)...............................................$7.65 ea ❑ Meter/mast repair........................................................$68.25 ❑ Low voltage systems.................................................$59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) .................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service...........................$86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ................ $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER' PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: W� js�u Date: Print Name: OLT!, e%n Day Telephone: 'l0l0- 2b�-IO�OSy Mailing Address: (ociy 3y+% Oat sw set4t . Ul7g 9 W-6 City State Zip H:\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: July 2013 bh Page 2 of 2 DESCRIPTIONS• PermitTRAK QUANTITY PAID $181.54 EL15-1028 Address: 14426 58TH AVE S Apn: 3365901214 $181.54 ELECTRICAL $174.56 PERMIT FEE SINGLE FAMILY R000.322.101.00.00 0.00 $139.65 PLAN CHECK FEE R000.345.832.00.00 0.00 $34.91 TECHNOLOGY FEE $6.98 TECHNOLOGY FEE TOTALR6797 R000.322.900.04.00 0.00 $6.98 $181.54 Date Paid: Monday, December 07, 2015 Paid By: AMY BEAUDOIN Pay Method: CREDIT CARD 015580 Printed: Monday, December 07, 2015 8:41 AM 1 of 1 �,, ��' 1��wSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: a.m Z Zi p.m. Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. ,,I- r I n IM nspector: REINSPECTI0P FEE REQUIRtD. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. / INSPECTION RECORD (���®� l Retain a copy with permit _ INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: 24 /1 ,V Date Called: Special Instructions: Date Wanted: / a.m p.m. Requester: dtg'i&' Phone No: jj 5716 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. CL O � is _• cn W C ` _ � � L, 1 ,� � � �0- L c� E � 0 Q ®3S W i�VZ u'� N p— ® Loa'—LU >> M Z V w eC � CL CL �, I-u 5 Z !u O C o Z W U D Va. iX0 U Co CD .0 R E Lirp m >c roa Doo C O O O Q, as C cL! CO) b c� — (U � o E •c c' m 2, m Q ? 5 .o O �.. _a m $ tC cn O CO == ro c Qm C H ; •Rf �• ,� p o CD O'�� . Z > 2 03 >, U F ® C 47 •� .f 4MM/ X N m m m a is N N y N N uu u u u u u u u u a C U � c m c m m G c U E Q 0 LO :3 O x LY w Q LU a E u O m w Z Z Q o c6 O t00 N 0 N � Q z 0) W � Z LU N Q O X (D � � -0 U) -0 O U a� Q. a� p- O : Z Q 57 Z M o � a5 0 d 0 w � > Z LU W CL W M d V ei Ln J LU 0 J Y c c of F- a:Q LU Q Q IN N = U \xw p N O N V w C1 c LU O U� Y c c W _ * S p '3 _ U Z Z Q z 2 W Z la- J - � -� w w Y c Q LO N N � O J W 0 J m N O U Y c N N a 2 m Q O O a U O Z Q p N \U of a g w Q a w > Z 0 m Z UO W w Z o 0 o a J W Z d w Q H . N It" I'* In 0 I� cc N Z LLI N CD uw a g u Opp a N Z I Z I C) LI) x.a+/� � O�Y " Lu 5 :D L J N LUZ 00 oo w U , LU.Z I r" I 3 Lm S CL LyL O 6S LU w a 1 �m 1 i LU U UNF� >I2C7 amps co ~ N U w N ooLmn 00 N N W 1 U U U w V) ( �� } N M 1 �o0�it � w 0 w � � W �LI Q�ZU) /N Ln L — - -1� a z z 17) w U w 0 D z D H a-1 w a F z w J U CQ O Ca d > UU w U � m V z 2 00 j i N .O N R z O t0 :3 c0 V ayeV7 V7 � U N ui W 10 ': U Q o I� m Q N N aa(P o a O E E M°D > wrn > , NO3�W12Zo ULu zH� �LU LU �Fa- Lu l5OC7Z`�w ��N V)U>H� �"�:.3 NQO zZZJOUW~��wZ aaaF-— D:>LLWH O wx OxO �OOU L- OaaZ(Y��nuiW= a°'�'�oo 0u)22»x 0 w�w "Z w 8 wo J W a z = z wzY m UO U� wwm F u �z OZ a g w m lz z 0 C14 iC/3 > ui CL W. Ll- z C13 I ALI LG lC-G4 Mechanical Properties Cells 6 x 10 Cell Vendor LG Cell Type Monocrystalline l N-type Cell Dimensions 156.75 x 156.75 mm / 6 inches a of Busbar 12 (Multi Wire Busbar) Dimensions (L x 1N x H) 1640 x 1000 x 40 mm 64.57 x 39.37 x 1.57 inch Front Load 6000 Pa / 125 psf 0 Rear Load 5400 Pa / 1 13 psf o Weight 170 t 0.5 kg / 37.48 t 1.1 lbs Connector Type MC4, MC4 Compatible, IP67 Junction Box IP67 with 3 Bypass Diodes Length of Cables 2 x 1000 mm / 2 x 39,37 inch Glass High Transmission Tempered Glass Frame Anodized Aluminum Certifications and Warranty Certifications IEC 61215, IEC 61730-1 /-2 IEC 62716 (Ammonia Test) IEC 61701 (Salt Mist Corrosion Test) ISO 9001 UL 1703 Module Fire Performance (USA) Type 2 (UL 1703) Fire Rating (for CANADA) Class C (ULC/ORD C1703) Product Warranty 12 years Q Output Warranty of Pmax Linear warranty* * 1)1 st year 93%2) After 2nd year. 0.6%p annual degradation, 3) 83.6%for 25 yeas Temperature Characteristics NOCT 46 t 3 °C Pmpp -0.38 %/°C Voc -0.28 �o/°C Isc 0.03 %/°C Characteristic Curves < 09 r CO Voltage N) p00 SGJ t;`vv t50:� 7300 1500 _, t,. 35 PG <0 Cv' t5 tp 75 n i5 CO.T J Temnmahrte j=Cj 3) Electrical Properties (STC *) v REVIEW ��Tt� GpMPLIAN NVPA70 - NEC Module Type MPP Voltage (Vmpp) MPP Current (Impp) 9.50 Open Circuit Voltage (Voc) 40.6 Short Circuit Current (Isc) U Module Efficiency (%) I 1 Operating Temperature (°C) Maximum System Voltage (V) 1000 Maximum Series Fuse Rating (A) 20 Power Tolerance (%) 0 - +3 * STC (Statdard Test Conditionk Irradiance 1000 W/nr, Module Temperature'S'C, AM 1.5 `The nameplate power output is measured and determined by LG Electronic at its sole and absolute discretion. ' The typical change in module efficiency at 200 W/O in relation to 1000 We is -2.09L Electrical Properties (NOCT*) Module Type 315 W Maximum Power (Pmax) 230 MPP Voltage (Vmpp) 30.4 MPP Current (Impp) 7.58 Open Circuit Voltage (Voc) 37,6 Short Circuit Current (Isc) 8.08 * NOCT (Nom,"A Operating Cell Temperature) Irradiance 800 W/m-. ambient temperature '-0Of— wind speed t m/s Dimensions (mm/in) ' The distance between the center of the mounting/grounding holes. I ® L^ North America Solar Business Team Product specification lane subject to change without notice. V LG Electronics U.S.A. Inc DS-N2-60-C-G-F-EN-50427 Lifers Good 1000 Sylvan Ave, Englewood Cliffs, N1 07632 Copyright © 2015 LG Electronics. All rights reserved. Contact: lasolar(oNge.com 01 /04/2015 vVvM lq_sofarusa.eom Innovation for a Better Life �•� CP-250-60-72-208/240-MC4 Microinverter Specifications INPUT DATA (DC) 1 1EVIEWE:n CX10 Recommended input power (STC) 190 - 330 W Maximum DC input voltage 60 V MPPT voltage range 22 — 38.5 V Operating range 18 — 38.5 V Min./Max. start voltage 22 — 47 V UPLIANCE WITH NFPA 70 - NEC DEC 0 2 2015 Max. DC input short circuit current 21 A City of Tukwila Max. DC input current 12 A BUILDING DIVISION. Ground fault protection Transformer isolated 2000 Vrms input/output/chassis OUTPUT DATA (AC) @ 208 V @ 240 V Peak sustainable output power Rated output power Max. continuous output current Nominal output voltage / range Extended output voltage range Nominal frequency / range Extended frequency range Power factor Maximum units per 20 A branch circuit Maximum output fault current & duration 250 W 220 W 1.20 A (250 W @ 208 V) 208 / 183 — 229 V 133 / 150 / 166 — 250 V 60.0 / 59.3 — 60.5 Hz 54.22 — 66.75 Hz > 0.95 13 1.6 A peak for > 100A of any cycle 250 W (285W extended range) 220 W 1.04 A (250 W @ 240 V) 240 / 211— 264 V 153 / 173 / 192 — 288 V 60.0 / 59.3 — 60.5 Hz 54.22 — 66.75 Hz > 0.95 15 1.6 A peak for > 10% of any cycle Maximum output overcurrent protection 6.3 A 6.3 A EFFICIENCY CEC weighted efficiency 96.09 % Peak inverter efficiency 96.6 % Static MPPT efficiency (EN 50530) 99.5 % - 99.8 % Night time power consumption 40 mW @ 208V, 80 mW @ 240 V MECHANICAL DATA Ambient temperature range -40"C to +65*C Dimension (W x H x D) including connectors 12" x 8" x 1.8" Weight 1.55 kg (3.4 lbs) Enclosure rating NEMA 4X FEATURES Communication Monitoring Compliance Compatibility 0As, Chilicon Power �ITI� Power line (130.2 kHz carrier) Free monitoring via gateway or online software UL1741, IEEE std 1547, IEEE std C62.41.2, CSA C22.2 NO. 107.1 & CISPR 22 Class B 60/72 cell PV modules with compatible input voltage range specifications above To team more about Chilicon Power Microinverters, visit chiliconpowercom t Helio Standard Rail WNM(XftFF-:__TJ Sunmodo's newly launched Helio Standard Rail is a cost-effective rail especially designed for its strength and versatility. Calculated Span Chart on page 16 With two convenient 1./4" slot and a 3/8" slot available, the Helio standard rail can handle a variety of components such as mounts, rail splic- es, micro -inverters, clamps, and a variety of wire and grounding products. Manufactured in 4 stock sizes in clear or black anodized. Sunmodo can also supply rail at any lengths. Sunmodo Rail is extruded 6065-T5 aluminum. Mack" NumberPart Description Standard Clear Anodized A20144-084 84" 8.31bs. Aluminum Rail 84" Standard Clear Anodized A20144-124 124" 12.27lbs. Aluminum Rail 124" Standard Clear Anodized A20144-164 164" 16.22lbs. Aluminum Rail 164" Standard Clear Anodized A20144-206 206" 20.371bs. Aluminum Rail 206" NumberPart Description Standard Black Anodized A20144-084-BK 84" 8.31bs. Aluminum Rail 84" Standard Black Anodized A20144-124-BK 124" 12.27lbs. Aluminum Rail 124" Standard Black Anodized A20144-164-BK 164" 16.22lbs. Aluminum Rail 164" Standard Black Anodized A20144-206-BK 206" 20.37lbs. Aluminum Rail 206" i Uh WITH IEC 15 Gila ISION -ftV12- Hello Rail Span Chart Notes SUNM*.m%a (1. Calculations assume the following support conditions: A) Two standard rails and two heavy rails are used to support modules pe rpe ndicular to the long edge of the modules. B) The shared rail supports the module s paralle I to the long edge of the modules. C) Module size assumed as approximately 66' x 40' with approximate weight of 48LB. D) Tributary width = 2.75' for standard and heavy rails, and 3.33' for shared rail. 2_. Me following load combinations are used: A) D+ W (controls in shaded area on left) B) D+ 0.755+ 0.75W (controls in unshaded area) C) D+ S (controls in shaded area on right) ( Rail -section properties shown on Sunmodo drawings A20144, A20145, A20146 and A20149. 4... Span lengths shown is: Between supportpoints. Simple span conservatively assumed for lengths over 4'6" and continuous sp an condition used for lengths 4'6' and under. S._Allowable cantilever -length past last support: May be up to 1/3 the span shown in the table. r6.. Wind -and -snow -loads: To be determined based on site specific and local code criteria. Properties Units Standard Rail A20144 Heavy Rail A20145 Material N/A Aluminum 6005-T5 Aluminum 6005-T5 Finish N/A Clear and Black Clear and Black Approx. Weight (per linear ft) plf .850 1.143 Total Cross Section Area in2 .723 .973 Section Modulus (X—Axis) in3 .387 .683 Section Modulus (Y--Axis) in3 .190 .333 Moment of Inertia (X--Axis) in4 .486 1.049 Moment of Inertia (Y--Axis) in4 .095 .209 Radius of Gyration (X--Axis) in .820 1.093 Radius of Gyration (Y--Axis) in .363 .61.2 Hello Standard Rail A20144 Snow Load (psf) 0 10 20 30 40 50 60 1 70 1 80 }....8.............a....8..�......b....�..3.........6.9........»6» ...10 """ F ...._....5...3.....i...5..�......i....4.6......i....4...."..... 15 } 8' 0" 79" 7' 0" € 6' 6" 6' 0" ) 5' 3" 5' 0" i 4' 6" 4' 3" ................•.i................... j.................. 4.................. 4.................. 1................... H..».».»«..... .•................................... .................. 20 ; 7' 6" ; 7' 3" 6' 9" € 6' 3" 5' 9" 5' 3" 5' 0" I 4' 6" I 4' 3" 25 0" "............. i.» 7.................. 0"..1.....5 6„ 5..0....t . 4' 9" 4_ 6 ._ 1..»4..3.... »i..................713" .................._................ ......... a.... ...............................................s... ....a 30 tw i 6' 9"VT �, 6' 3" 519" 5'3" 510"419"4' 6" 413" 35 :............._................._....................................:...................................... 1 6' 3" 6' 3" 6' 0" 1 5' 6" 5' 0" 4' 9" 4' 6" 4' 3" 4' 0" v..................:..................:..................:...................:...................................: .... . ....:.... ......... . ....: ......... ....4 ........ _.0 .... 6' 0" 610" E 5' 9" 5' 3" 5' 0" 419" «.......... 416" «.................. '" ......40 ............................................ ......45 _.....I..........I....................;.................. ('....5191... i...»5.9........»5161 ............: . .................. 5'0" 41911 .....................................,..................:.................. 4' 611 .... 41314 i....4..0 .... v 50 5' 3" 5' 3" 5' 3" 5' 0" 1 419" 4' 6"4'3" ....4..0..........4.'0" c.................. ................. ...... 3 55 5' 0" 5' 0" 5' 0" 4' 9" 4' 6" 4' 3" 4' 0" 4' 0" 4' 0" ..................p..................,..................*,,..............,....................,..................y.................. 60 5 0' € 5' i • ........................................... a.................. ;................... 4' 9" i 4' 6" 4' 3" '; q.................. r..................,.................. 4' 0" 4' 0" 4' 0" 65...4.9...._1..._41 b..................................... 1 gli 41911 c 4' 611 i 4' 3" b..................I...................j.. 41011 41011 ................ 4' 011 41011 ....... .7U ...... ........ ........... I...... E 4' 6" 4' 6" 4' 6" ', ..................................... a.................. b..................1...................,................. ..................1.................. a.................. 4' 6" '; 413" b..................1................... t........... 4' 0" '• 4' 0" 4' 0" '• s.................. i...................i................. ....... 4' 0" 75 ....... 4' 6" 4' 6" 4' 6" b...................................... .................. 4' 3" 4' 0" ......................................................... • 4' 0" 1 a 4' 0" 4' 0" 3' 9" 80 ) 4' 3" 1 4' 3" ':. 4' 3" i 4' 3" 1 4' 0" ...................................... 4' 0" 1 4' 0" 1 4' 0" 1 3' 9" Hello Heavy Rail A20145 Snow Load (psf) 0 10 20 30 1 40 1 50 60 1 70 1 80 10 i 10' 6" € 9' 9" 9' 0" 8' 3" 7 9 7' 311 9" .......5- 15 ......................................1.................. 1: g' 9" i 9-3" a.................. 816" a.................. 813" ' 1.................. 719" 713" 6-6" ' a..................i.................. 6' 0" 519" 20 i' 9' 3" : k..................i.................. 9' 0" 8' 3" 1 8' 0"....1...»�».........1......»0.... .................. 6' 6" 6_0_»....»5......... 25... $. ��.........8 a..................4.............. 5.».s....8..3......�... T 9"....i.......»3•.....>...»6.»9.....d....6..3......i.... � m 6.0..... t 5'9" 30 8 3" 8' 3" i 8' 0" 1 7' 6" 7' 0" 6' 6" : 6' 3" 6' 0" 5' 6" .......2 ...................i..................E..................L..................1..................s..................4..................4..................i.................. 35 1, 8' 0" 8' 0" 7' 9" '• 7' 3" ': 6' 9" 6' 3" 6' 0" 5, 9" 5' 6" a:...................:............................................... ......:........ ..... ...... _ ...... .... ` 40 j T 9 7 9 1 7' 6" 1 7' 0" 1 6' 6" 6' 3" 6� 0" 5 6 5�'6" 0 .....................................:.................._..................>..................:.... 3" 1 6' 9" 1 6' 3" € .............._............. 6' 0" 5' 9" 5' 6" ............. 5' 3" c I..................:................:.Z..................:..................:..................;.................._...................................................... 71311 71311 € 7' 0" 1 6" 1 6- 613" 610" 516" 516" 5'3" 3 ....._50 ............................................. ......6191 .......�.................. 61 911 I .................. *..»....»...........................,...................;.................._..................;...................;.................. .................:................ 61911 6, 3" ' 610„ 51 g11 : 516" 5' 3" I 510" 60 i 6' 6" .............. ......................,....................................,..................,..................y 6' 6" b' 6" 6' 3" 6' 0" 1 5' 6" 1 .................. 5' 6" .................. 5' 3" ;................... 5' 0" 65 6' 3" . 6' 3" 6' 3" ` 6' 0" 1 5' 9" 5' 6" 5' 3" 5' 0" 1 5' 0" .......;...................1..................q..................Z..................;..................q..................i...................f•..................,.................. 0" 6' 0" 1 6' 0" i 6' 0" 1 5' 6" .................. 75 1 6' 0" ..........a................... 6' 0' i .................. 6' 0" ,.................. 5' 9" a.................. 5' 6" 1 a.................. 5' 3" ,................... 5' 0" ,................... 5' 0" 4' 9" .......L ..................j.................. a.................. ..................1 ................... >..................b .................. i...................i................... 5' 9" ! 5' 9" 5' 6" 1 5' 6" 5' 3" ? 5' 0" 4, 9" 4' 9" - Pmm is CQWll - 17tCOlUL1GJ1C1", 1-1'llAJC 1v1Qll1 LUg, iUUIMULu l r)UNN LUdLL L... ULLPSa/p1QLL.CUMIPIaLL-CIUL:UI4;-SUPPIYItil tLllllllLLlll-D UN8-L )aU-I,CllLCIS... (800)257-5288 Sign In or Register platt.com Home Power Distribution Load Centers / Panelboards Aluminum Buss Load Centers 1-Phase Main Lug Eaton BR816L125RP 125A, 120/240V, 1P, 8/16, ML Loadcenter, NEMA 3R Item: 357768 Cat: BR8161_125RP $127.46 EA Mfg: Eaton UPC: 786676001472 ---------•----- 126 available I Catalog Page j r Details I I Reviews (0) Qty: F1 — !J Add to Cart 125 AMP, 120/240V AC, 1-Phase, Main Lug Loadcenter, 8-Space, 16-Pole, Aluminum Bus, Cover: Surface, NEMA 311 - Rainproof. Includes: Hub Closure Plate. Dims: H: 13", W: 11", D: 3.56" Platt Cat: CUTBR8161_12511P `VoRs AC: 120, 240 Platt Item: 357768 IP/NEMA 3R Mfg: Cutler -Hammer, Eaton, I Rating: Westinghouse I Circuits: 16 i UPC: 786676001472 ,Phase: 1 Category: 1-Phase Main Lug Type: Main Lug, Aluminum Buss 'Family / Style: BR � Spaces: 8 Mounting: Surface Amps: 125 • Category: Power Distribution Load Centers / Panelboards Aluminum Buss Load Centers 1-Phase Main Lug • Products related to BR816L125RP 125A, 120/240V, 1P, 8/16, ML Loadcenter, NEMA 3R or visit the Eaton site. • For help with 125A, 120/240V, 1P, 8/16, ML Loadcenter, NEMA 311 from Eaton, call Platt at 800-257-5288 from 4a - 8p (pst) 7 days. • Click "Add to Cart" to buy Eaton BR8161_125RP 125A, 120/240V, 1P, 8/16, ML Loadcenter, NEMA 3R. • Also known as: 786676001472, CUIBR816L125RP, Eaton, BR8161_125RP, 1-Phase Main Lug, Aluminum Buss Load Centers, Load Centers / Panelboards, Power Distribution, subpanel, Cutler -Hammer, Westinghouse cg) Copyright 2001-2015 Platt Electric Supply, All Rights Reserved. - IrE1t(fr�(�(c� LE DEC 0 2 2015 oil, iY1�dC' L C1J�4C L�F� 1 of 1 4/3/ 15, 8:16 AM —UU1)CI D-L1llC - U111VIOLO, 1V1CLC1 OUCICCLS - VV1L11UUt DYPdSS, 1V1CLCIS... 11Lt11S: / / Platt. coin/ Platt-C1CL:tlll:-S UP1.11Y / LV1CtCIs-HcuCSSUI ICS-1V1CLC1-JUI:... (800)2S7-S288 Sign In or Register platt.Com Home Power Distribution Metering & Temporary Power Meters & Accessories Meter Sockets -Without Bypass Cooper S-Line 011MS25 100A, 1P, 4 Jaw, Solar Meter Socket Item: 100334 Cat: 011MS25 $72.43 EA •emu. Mfg: Cooper B-Line UPC: Not Available :--- -- ---- --- 46 available Cut Sheet--- i Qty:� 1!/ Add to Cart La Details I I Reviews (0) 100 Amp, 1-Phase, 4 Jaw, Ring -Type. 3-Wire, 600V, Surface Mount, Top Feed, NEMA 3R. Solar Rated. HxWxD: 12" x 8" x 4-5/8". Platt Cat: CIR011MS25 'Volts AC: 600 Platt Item: 100334 IP/NEMA 3R B-Line, Cooper B-Line, Cooper :Rating: Mfg: B-Line DATA Phase: 1 UPC: Not Available Top/Overhead, Ring Type, Solar Category: Meter Sockets - Without Bypass Type. Ready Mounting: Surface Sockets: 1 Amps: 100 laws: 4 ` • Category: Power Distribution Metering & Temporary Power Meters & Accessories Meter Sockets - Without Bypass • Products related to 011MS25 SODA, 1P, 4 Jaw, Solar Meter Socket or visit the Cooper B-Line site. • For help with 100A, IP, 4 Jaw, Solar Meter Socket from Cooper B-Line, call Platt at 800-257-5288 from 4a - 8p (pst) 7 days. • Click "Add to Cart" to buy Cooper B-Line 011MS25 100A, 1P, 4 Jaw, Solar Meter Socket. • Also known as: CIRO11MS25, Cooper B-Line, 011MS25, Meter Sockets - Without Bypass, Meters & Accessories, Metering & Temporary Power, Power Distribution, Cooper B-Line DATA, B-Line cp Copyright 2001-2015 Platt Electric Supply, All Rights Reserved, P 1r`11 TV-11azl �c 1 of 1 4/1/15. 11:42AM ' Ez Mount tandeff for Shingle Roofs �er r_ �ry t + +c•�tS '►S t?"SS�. �,.;,A. ..r�.�w•,� . td� • .I` i F ; • l •'�!_ w .% r V ¢�'(�V' '!�� " •"f°'�' v Y: ���♦til •Y .:;�- • •��r,��& ,�� �.,•`4 :e . ,�,�i..�,��r2 S�� i��.Gr4�k, F ��.,.`•�Yr Y�"*i�?r� • a• �y� ...r R r .� LirK �� h - ��L r •;.ati t'i 1d,.r <[^?' ��"�" '�. lse t � �%:.4�t�� `yam. fi `r,. a ` �y �r'� .�Y' �5�+��♦a rt .t 1 `-�j�. ' 1" S rt4�1-! • T;:'K '' *t %� f a, f �ws• bi+Q� ,'�''. f\tii{,,ti i/•7 ,� �.la�'1r `r ''1•,+S tt�l ! '"r��• 'f. ��.,i 4 �' < • ` ' vt t\C r � I j � n i r l , f ., v . �'R Yes t" � 1 f ta,•^a t `S;v �r. f:�s9'1!"fir., .Z= / tLt ff7 M. '�j.�{f t'�y '� � t ¢'�. '♦ C - '...r ;'` �`�.Zfr'!.>.'.%r f ��� �.'!�T,��� , , ! �' !f c'S'a.r d .l` •±'�i f tr JN' ! j''t' 1 - -R" 3• • /'; ,• yRY��.- `. �:r, , I f(; , jiP► 1 { ii ! Z ��J f} r~vC' ! n + Y t ' LS t ty - ` +•fix s. ' ♦ `► t '" �' +, r .� df t I r •Y f +,ry y.+ t ti • � ( r AILS. aA %a r a` ..��In� ♦ " �i /3y �. �•,J ,rM • a d •� �b'+i .aJ" /.. ♦y a , 9/ ,..1` of �I •.. ' ,`JF't ♦f1'�'�t a;aY; Z tr _•M fi. i.4 A • i9r rf }F. l� 4tit� r� r �, 1t" j'{ Ntv,♦ ram. Nita 1�.,:•.�' • j r�•1s ,.+�' 'Ow s �, • �1 N '� \ • r 1 �� .•vfy � y � �"' !a ' .A . �frf■La .. � ♦ Itt ; v ` i \1 a ?♦�� `i^I .{ •�, t: / Jd I �'! 'W h � .t 7 f t, r 1 k'i" � � W 4 �• •t,� •' 'N � r ! r � � •+ i f rr: a�j,t. :e l � ♦ .. /. •L . ai tt ! a S • ♦ ♦' �..'`'iI•ai' r:" I •;�,y + r I Ia t� Pi 'ij ! �•,. i T t / • \ r L ♦ Ri ♦ • 4.ar ���' aS \ f ' 1, {•.j it t 'v R\_� � /•i r ' r � �f.C^t .. ,,�f a,. : y {�• t•'In t • j'ta�l I • �y'� {fit ''�,ja'P� `t rif�{,�� #�. 1�+� • r ` k�i��.r��r�,jY :♦•t �,,.� .r.,s.r•('. ri��t'•hj 11� •♦1�C�•♦ ♦ R�L;` f��pN'� C'��t. �f• dh�'��?y�� Jf, r ♦ t .44 *S /}4 , t ' t ,}c , ;e �„r. I. ^ :,� :@...?• _r 1'f.. +,�1: l '♦i' �N.al;*.,.,r� •��I•• � �.��{/r, '• R1 • t /f �J; .r.c ��"�. �+. !� � fi+�, ��`l ♦ r �' , fr♦t ��{. • �`'•':� �j I 'ti • �+ v;�i}ik; i�� I�C•tl!�rf2 "f � �;� +1,M•\.p,.�.Z� ri', h.''�%a. l il�'r1l .I ti�'�'Yt � `� tai '1 t� ,rl/r `� �i_.�j /' 7�,C •i >N\`�]C: '`I r'�'t� ♦�r�'+�t'� ,*'ZS� a•+Js}It/i4 �'.G 1r' r r! •. its y ft 1�. a J14 1 �ti r yrr, :� a Ji♦ AS !,'♦� r Il �r f r r r•, ?� h w, J t• 1 tia 5,�:3 �i h ♦• t '�"�'• f"• yt• ' to 1.. 1 � ) 1� . 1.' ,�y t Jsaitssa • r . \ -v't ,tR`_i �a tea• � '; f'n1a,r . !" . _r'. r 4•.'f•:r:,tp'e.;r,r,-_.\t'�. •' •,Sf�o' irr .•iya ..' t•�'`4•sv.r •i�t•, „t.,'�.4t' ai� .4�`:a��4'r:�••; �:��' Ez Mount L Foot for Shingle Roofs also available! 1905 E 5th St., Ste. A Vancouver, WA 98661 Phone: 360-844-0048 www.sunmodo.com Ez Roof M&nt Engineered and Designed for easy installation. Our roof mounting system is water tight and durable for any composite/shake roof! Versatile aluminum base for Perfect for top mounting rail. Add a L Foot for side mounting multiple configurations. rails. Ez Mount Standoff for Shingle Roofs Kit# K10070-002 All kits come complete with the following parts: 1- Lag Bolt SS 5/16 x 4 1- Al Base Part# B15015-002 Part# A20065-001 pt ,fir► r�` ,t 1- Standoff 2" Part# A20049-002� hing '; 1- Bolt 3/ 8 -16 x 3/ 4" Part# A20052-001 1- Washer 3/8 1905 E 5th St., Ste. A Vancouver, WA 98661 Phone: 360-844-0048 www.sunr-c:dc. '-,.)m Also available: Black and Brown Flashing I ) 211, 3" and 5" Star Over sized flashing � SUNM(�` "' New Product Introduction - Self Grounding System SunModo is proud to announce our next generation self -grounding product line to simplify your solar installations. Our secret: Built-in grounding pins in easy - to -use components for any panel and rail configuration. No need to order, stock, and transport grounding clips and grounding straps to the rooftop. Grounding Solution for Panel Portrait Configuration Grounding Solution for Panel Landscape Configuration Key Features and Benefits: • The unique ground pin is integral to each component, providing the necessary grounding required under NEC 690.47 and UL 2703 • T-bolt locking feature ensures the T-Bolt remains vertical and in full contact to rail to eliminate pull out • Our system conveniently accommodates either portrait or landscape configuration to minimize roof time and parts required • Each grounding component is simple to install and torqued to the specification • No need to order, stock, and transport additional grounding hardware to the rooftop • Two granted patents, one patent pending filing Self -Grounding Portrait Mid Clamps: Our Mid Clamps have a proprietary "T" bolt assembly that includes the grounding pins in the rail slot of the rail base assembly. Self -Grounding Landscape Mid and End Clamps: Our system conveniently accommodates landscape configuration to minimize roof time and parts required. The adaptor converts standard rail to shared rail to allow landscape mounting of PV panels on E-W rails. Self -Grounding Rail Splices: The rail splices include grounding pins to assure a solid bond between the two rails being joined. Self -Grounding Lug: Completing our family of integral grounding products is our groundtn�rilf,- grounds to the rail, insuring tV��! system per UL 2703 and NEC90.4`�ly�'( rf(a info@sunmodo.com www.sunmodo.com 360-844-0048 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL15-1028 PROJECT NAME: HENRY BUI SITE ADDRESS: 14426 58TH AVE S X Original Plan Submittal Response to Correction Letter # DATE: 11/23/15 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ,tc. Building Division ® Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 11/24/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved a Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 12/22/15 Approved with Conditions 9 Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 WEST SEATTLE NATRL ENERG" LLC Page 1 of 2 Washington State Department of Labor & Industries Home Inicio en Espanol Contact Search L&I ahr ni A-Z.tndex Hell) Uty Secure I: lkI Safety Claims & Insurance Workplace Rights Trades & Licensing WEST SEATTLE NATRL ENERGY LLC Owner or tradesperson 6921 34TH AVE SW Principals SEATTLE, WA98126 p 206-469-8442 HUGHES, KEITH R, PARTNER/MEMBER KING County HUGHES, RYAN J, PARTNER/MEMBER HUGHES, AMY D, PARTNER/MEMBER HUGHES, LINDA G, PARTNER/MEMBER Doing business as WEST SEATTLE NATRL ENERGY LLC WA UBI No. Business type 602 845 435 Limited Liability Company Governing persons AMY D HUGHES KEITH RAY HUGHES; LINDA G HUGHES; RYAN J HUGHES; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ..................._......................... _..._ Meets current requirements. License specialties GENERAL License no. WESTSSN907NB Effective — expiration 08/02/2010— 08/04/2016 Designated administrator Active. GUTH, SIM Meets current requirements. License type License no. Master Electrician GUTH*S*973MG Bond ................. Wesco Insurance Co $4,000.00 Bond account no. 46-WBO51651 Received by L&I Effective date 07/16/2014 07/26/2014 Expiration date Until Canceled Bond history Savings No savings accounts during the previous 6 year period. https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602845435&LIC=WESTSSN907NB&SAW= 12/7/2015